Sample records for x-windows socket widget

  1. X-Windows Socket Widget Class

    NASA Technical Reports Server (NTRS)

    Barry, Matthew R.

    2006-01-01

    The X-Windows Socket Widget Class ("Class" is used here in the object-oriented-programming sense of the word) was devised to simplify the task of implementing network connections for graphical-user-interface (GUI) computer programs. UNIX Transmission Control Protocol/Internet Protocol (TCP/IP) socket programming libraries require many method calls to configure, operate, and destroy sockets. Most X Windows GUI programs use widget sets or toolkits to facilitate management of complex objects. The widget standards facilitate construction of toolkits and application programs. The X-Windows Socket Widget Class encapsulates UNIX TCP/IP socket-management tasks within the framework of an X Windows widget. Using the widget framework, X Windows GUI programs can treat one or more network socket instances in the same manner as that of other graphical widgets, making it easier to program sockets. Wrapping ISP socket programming libraries inside a widget framework enables a programmer to treat a network interface as though it were a GUI.

  2. X-Windows PVT Widget Class

    NASA Technical Reports Server (NTRS)

    Barry, Matthew R.

    2006-01-01

    The X-Windows Process Validation Table (PVT) Widget Class ( Class is used here in the object-oriented-programming sense of the word) was devised to simplify the task of implementing network registration services for Information Sharing Protocol (ISP) graphical-user-interface (GUI) computer programs. Heretofore, ISP PVT programming tasks have required many method calls to identify, query, and interpret the connections and messages exchanged between a client and a PVT server. Normally, programmers have utilized direct access to UNIX socket libraries to implement the PVT protocol queries, necessitating the use of many lines of source code to perform frequent tasks. Now, the X-Windows PVT Widget Class encapsulates ISP client server network registration management tasks within the framework of an X Windows widget. Use of the widget framework enables an X Windows GUI program to interact with PVT services in an abstract way and in the same manner as that of other graphical widgets, making it easier to program PVT clients. Wrapping the PVT services inside the widget framework enables a programmer to treat a PVT server interface as though it were a GUI. Moreover, an alternate subclass could implement another service in a widget of the same type. This program was written by Matthew R. Barry of United Space Alliance for Johnson Space Center. For further information, contact the Johnson Technology Transfer Office at (281) 483-3809. MSC-23582 Shuttle Data Center File- Processing Tool in Java A Java-language computer program has been written to facilitate mining of data in files in the Shuttle Data Center (SDC) archives. This program can be executed on a variety of workstations or via Web-browser programs. This program is partly similar to prior C-language programs used for the same purpose, while differing from those programs in that it exploits the platform-neutrality of Java in implementing several features that are important for analysis of large sets of time-series data

  3. X-Windows Information Sharing Protocol Widget Class

    NASA Technical Reports Server (NTRS)

    Barry, Matthew R.

    2006-01-01

    The X-Windows Information Sharing Protocol (ISP) Widget Class ("Class") is used here in the object-oriented-programming sense of the word) was devised to simplify the task of implementing ISP graphical-user-interface (GUI) computer programs. ISP programming tasks require many method calls to identify, query, and interpret the connections and messages exchanged between a client and an ISP server. Most X-Windows GUI programs use widget sets or toolkits to facilitate management of complex objects. The widget standards facilitate construction of toolkits and application programs. The X-Windows Information Sharing Protocol (ISP) Widget Class encapsulates the client side of the ISP programming libraries within the framework of an X-Windows widget. Using the widget framework, X-Windows GUI programs can interact with ISP services in an abstract way and in the same manner as that of other graphical widgets, making it easier to write ISP GUI client programs. Wrapping ISP client services inside a widget framework enables a programmer to treat an ISP server interface as though it were a GUI. Moreover, an alternate subclass could implement another communication protocol in the same sort of widget.

  4. Tools for the IDL widget set within the X-windows environment

    NASA Technical Reports Server (NTRS)

    Turgeon, B.; Aston, A.

    1992-01-01

    New tools using the IDL widget set are presented. In particular, a utility allowing the easy creation and update of slide presentations, XSlideManager, is explained in detail and examples of its application are shown. In addition to XSlideManager, other mini-utilities are discussed. These various pieces of software follow the philosophy of the X-Windows distribution system and are made available to anyone within the Internet network. Acquisition procedures through anonymous ftp are clearly explained.

  5. X-Windows Widget for Image Display

    NASA Technical Reports Server (NTRS)

    Deen, Robert G.

    2011-01-01

    XvicImage is a high-performance XWindows (Motif-compliant) user interface widget for displaying images. It handles all aspects of low-level image display. The fully Motif-compliant image display widget handles the following tasks: (1) Image display, including dithering as needed (2) Zoom (3) Pan (4) Stretch (contrast enhancement, via lookup table) (5) Display of single-band or color data (6) Display of non-byte data (ints, floats) (7) Pseudocolor display (8) Full overlay support (drawing graphics on image) (9) Mouse-based panning (10) Cursor handling, shaping, and planting (disconnecting cursor from mouse) (11) Support for all user interaction events (passed to application) (12) Background loading and display of images (doesn't freeze the GUI) (13) Tiling of images.

  6. Flu Widget

    MedlinePlus

    ... 0" width="300" title="Flu I.Q. Widget" style="overflow: hidden;"> Flu ... 0" width="280" title="CDC Flu Vaccine Finder" style="overflow: hidden;"> FluView Widget < ...

  7. Continuation of research into software for space operations support: Conversion of the display manager to X Windows/Motif, volume 2

    NASA Technical Reports Server (NTRS)

    Collier, Mark D.; Killough, Ronnie; Martin, Nancy L.

    1990-01-01

    NASA is currently using a set of applications called the Display Builder and Display Manager. They run on Concurrent systems and heavily depend on the Graphic Kernel System (GKS). At this time however, these two applications would more appropriately be developed in X Windows, in which a low X is used for all actual text and graphics display and a standard widget set (such as Motif) is used for the user interface. Use of the X Windows will increase performance, improve the user interface, enhance portability, and improve reliability. Prototype of X Window/Motif based Display Manager provides the following advantages over a GKS based application: improved performance by using a low level X Windows, display of graphic and text will be more efficient; improved user interface by using Motif; Improved portability by operating on both Concurrent and Sun workstations; and Improved reliability.

  8. Widgets and Buttons

    MedlinePlus

    ... Home → Widgets and Buttons URL of this page: https://medlineplus.gov/widgets.html Widgets and Buttons To ... link the word MedlinePlus to the MedlinePlus homepage ( https://medlineplus.gov/ ). Search MedlinePlus : To put the MedlinePlus ...

  9. OntologyWidget - a reusable, embeddable widget for easily locating ontology terms.

    PubMed

    Beauheim, Catherine C; Wymore, Farrell; Nitzberg, Michael; Zachariah, Zachariah K; Jin, Heng; Skene, J H Pate; Ball, Catherine A; Sherlock, Gavin

    2007-09-13

    Biomedical ontologies are being widely used to annotate biological data in a computer-accessible, consistent and well-defined manner. However, due to their size and complexity, annotating data with appropriate terms from an ontology is often challenging for experts and non-experts alike, because there exist few tools that allow one to quickly find relevant ontology terms to easily populate a web form. We have produced a tool, OntologyWidget, which allows users to rapidly search for and browse ontology terms. OntologyWidget can easily be embedded in other web-based applications. OntologyWidget is written using AJAX (Asynchronous JavaScript and XML) and has two related elements. The first is a dynamic auto-complete ontology search feature. As a user enters characters into the search box, the appropriate ontology is queried remotely for terms that match the typed-in text, and the query results populate a drop-down list with all potential matches. Upon selection of a term from the list, the user can locate this term within a generic and dynamic ontology browser, which comprises the second element of the tool. The ontology browser shows the paths from a selected term to the root as well as parent/child tree hierarchies. We have implemented web services at the Stanford Microarray Database (SMD), which provide the OntologyWidget with access to over 40 ontologies from the Open Biological Ontology (OBO) website 1. Each ontology is updated weekly. Adopters of the OntologyWidget can either use SMD's web services, or elect to rely on their own. Deploying the OntologyWidget can be accomplished in three simple steps: (1) install Apache Tomcat 2 on one's web server, (2) download and install the OntologyWidget servlet stub that provides access to the SMD ontology web services, and (3) create an html (HyperText Markup Language) file that refers to the OntologyWidget using a simple, well-defined format. We have developed OntologyWidget, an easy-to-use ontology search and display

  10. Development of socketed foundations for S3X5.7 posts.

    DOT National Transportation Integrated Search

    2015-04-01

    The objective of this study was to develop a socketed foundation for use with the S3x5.7 (S76x8.5) weak : post. The design focused on cylindrical, reinforced concrete foundations with a steel tube placed in the center for : use as the socket. The fou...

  11. OntologyWidget – a reusable, embeddable widget for easily locating ontology terms

    PubMed Central

    Beauheim, Catherine C; Wymore, Farrell; Nitzberg, Michael; Zachariah, Zachariah K; Jin, Heng; Skene, JH Pate; Ball, Catherine A; Sherlock, Gavin

    2007-01-01

    Background Biomedical ontologies are being widely used to annotate biological data in a computer-accessible, consistent and well-defined manner. However, due to their size and complexity, annotating data with appropriate terms from an ontology is often challenging for experts and non-experts alike, because there exist few tools that allow one to quickly find relevant ontology terms to easily populate a web form. Results We have produced a tool, OntologyWidget, which allows users to rapidly search for and browse ontology terms. OntologyWidget can easily be embedded in other web-based applications. OntologyWidget is written using AJAX (Asynchronous JavaScript and XML) and has two related elements. The first is a dynamic auto-complete ontology search feature. As a user enters characters into the search box, the appropriate ontology is queried remotely for terms that match the typed-in text, and the query results populate a drop-down list with all potential matches. Upon selection of a term from the list, the user can locate this term within a generic and dynamic ontology browser, which comprises the second element of the tool. The ontology browser shows the paths from a selected term to the root as well as parent/child tree hierarchies. We have implemented web services at the Stanford Microarray Database (SMD), which provide the OntologyWidget with access to over 40 ontologies from the Open Biological Ontology (OBO) website [1]. Each ontology is updated weekly. Adopters of the OntologyWidget can either use SMD's web services, or elect to rely on their own. Deploying the OntologyWidget can be accomplished in three simple steps: (1) install Apache Tomcat [2] on one's web server, (2) download and install the OntologyWidget servlet stub that provides access to the SMD ontology web services, and (3) create an html (HyperText Markup Language) file that refers to the OntologyWidget using a simple, well-defined format. Conclusion We have developed OntologyWidget, an easy

  12. Emotion scents: a method of representing user emotions on GUI widgets

    NASA Astrophysics Data System (ADS)

    Cernea, Daniel; Weber, Christopher; Ebert, Achim; Kerren, Andreas

    2013-01-01

    The world of desktop interfaces has been dominated for years by the concept of windows and standardized user interface (UI) components. Still, while supporting the interaction and information exchange between the users and the computer system, graphical user interface (GUI) widgets are rather one-sided, neglecting to capture the subjective facets of the user experience. In this paper, we propose a set of design guidelines for visualizing user emotions on standard GUI widgets (e.g., buttons, check boxes, etc.) in order to enrich the interface with a new dimension of subjective information by adding support for emotion awareness as well as post-task analysis and decision making. We highlight the use of an EEG headset for recording the various emotional states of the user while he/she is interacting with the widgets of the interface. We propose a visualization approach, called emotion scents, that allows users to view emotional reactions corresponding to di erent GUI widgets without in uencing the layout or changing the positioning of these widgets. Our approach does not focus on highlighting the emotional experience during the interaction with an entire system, but on representing the emotional perceptions and reactions generated by the interaction with a particular UI component. Our research is motivated by enabling emotional self-awareness and subjectivity analysis through the proposed emotionenhanced UI components for desktop interfaces. These assumptions are further supported by an evaluation of emotion scents.

  13. Widgets to the Rescue

    ERIC Educational Resources Information Center

    Kroski, Ellyssa

    2008-01-01

    A widget displays Web content from external sources and can be embedded into a blog, social network, or other Web page, or downloaded to one's desktop. With widgets--sometimes referred to as gadgets--one can insert video into a blog post, display slideshows on MySpace, get the weather delivered to his mobile device, drag-and-drop his Netflix queue…

  14. Wired Widgets: Agile Visualization for Space Situational Awareness

    NASA Astrophysics Data System (ADS)

    Gerschefske, K.; Witmer, J.

    2012-09-01

    Continued advancement in sensors and analysis techniques have resulted in a wealth of Space Situational Awareness (SSA) data, made available via tools and Service Oriented Architectures (SOA) such as those in the Joint Space Operations Center Mission Systems (JMS) environment. Current visualization software cannot quickly adapt to rapidly changing missions and data, preventing operators and analysts from performing their jobs effectively. The value of this wealth of SSA data is not fully realized, as the operators' existing software is not built with the flexibility to consume new or changing sources of data or to rapidly customize their visualization as the mission evolves. While tools like the JMS user-defined operational picture (UDOP) have begun to fill this gap, this paper presents a further evolution, leveraging Web 2.0 technologies for maximum agility. We demonstrate a flexible Web widget framework with inter-widget data sharing, publish-subscribe eventing, and an API providing the basis for consumption of new data sources and adaptable visualization. Wired Widgets offers cross-portal widgets along with a widget communication framework and development toolkit for rapid new widget development, giving operators the ability to answer relevant questions as the mission evolves. Wired Widgets has been applied in a number of dynamic mission domains including disaster response, combat operations, and noncombatant evacuation scenarios. The variety of applications demonstrate that Wired Widgets provides a flexible, data driven solution for visualization in changing environments. In this paper, we show how, deployed in the Ozone Widget Framework portal environment, Wired Widgets can provide an agile, web-based visualization to support the SSA mission. Furthermore, we discuss how the tenets of agile visualization can generally be applied to the SSA problem space to provide operators flexibility, potentially informing future acquisition and system development.

  15. Alternative Fuels Data Center: Widgets

    Science.gov Websites

    Efficiency and Renewable Energy Get Widget Code × Widget Code Select All Close Vehicle Cost Calculator Share a tool to calculate annual fuel cost and greenhouse gas emissions for alternative fuel and advanced technology vehicles. Vehicle Cost Calculator Choose a vehicle to compare fuel cost and emissions with a

  16. VizieR Data Extraction Disseminated through Widgets

    NASA Astrophysics Data System (ADS)

    Landais, G.; Boch, T.; Ochsenbein, F.; Simon, A.-C.

    2015-09-01

    The CDS widgets are a collection of web applications easily embeddable in web pages. The Apache Shindig framework, relying on OpenSocial specification, enables to reuse code in any web page by giving interactive output and broadcasting capabilities: for instance to use the result of a search widget to populate other widgets. Some of these widgets are already used in the VizieR web application. The “plot widget” is used to illustrate associated data like time-series or spectra coming from publications. The data extracted with a SQL-like language (which can operate with different type of resources like FITS, ASCII files, etc.) are then disseminated in a “plot widge” that is ergonomic and contains evolved customization capabilities. The VizieR photometry viewer is the result of filter gathering and pipeline automatization: the interface use a dedicated widget that integrates three linked views: a photometry point, a sky chart and the VizieR tabular data.

  17. Alternative Fuels Data Center: Vehicle Cost Calculator Widget Assumptions

    Science.gov Websites

    Data Center: Vehicle Cost Calculator Widget Assumptions and Methodology on Facebook Tweet about Alternative Fuels Data Center: Vehicle Cost Calculator Widget Assumptions and Methodology on Twitter Bookmark Alternative Fuels Data Center: Vehicle Cost Calculator Widget Assumptions and Methodology on Google Bookmark

  18. NASA Tech Briefs, February 2006

    NASA Technical Reports Server (NTRS)

    2006-01-01

    Topics discussed include: Nearly Direct Measurement of Relative Permittivity; DCS-Neural-Network Program for Aircraft Control and Testing; Dielectric Heaters for Testing Spacecraft Nuclear Reactors; Using Doppler Shifts of GPS Signals To Measure Angular Speed; Monitoring Temperatures of Tires Using Luminescent Materials; Highly Efficient Multilayer Thermoelectric Devices; Very High-Speed Digital Video Capability for In-Flight Use; MMIC DHBT Common-Base Amplifier for 172 GHz; Modular, Microprocessor-Controlled Flash Lighting System; Generic Environment for Simulating Launch Operations; Modular Aero-Propulsion System Simulation; X-Windows Socket Widget Class; Infrastructure for Rapid Development of Java GUI Programs; Processing Raman Spectra of High-Pressure Hydrogen Flames; X-Windows Information Sharing Protocol Widget Class; Simulating Humans as Integral Parts of Spacecraft Missions; Analyzing Power Supply and Demand on the ISS; Polyimides From a-BPDA and Aromatic Diamines; Making Plant-Support Structures From Waste Plant Fiber; Large Deployable Reflectarray Antenna; Periodically Discharging, Gas-Coalescing Filter; Ion Milling On Steps for Fabrication of Nanowires; Neuro-Prosthetic Implants With Adjustable Electrode Arrays; Microfluidic Devices for Studying Biomolecular Interactions; Studying Functions of All Yeast Genes Simultaneously; Polarization Phase-Compensating Coats for Metallic Mirrors; Tunable-Bandwidth Filter System; Methodology for Designing Fault-Protection Software; and Ground-Based Localization of Mars Rovers.

  19. Window type: 2x3 fixed multipaned steel window flanked by 1x3 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Window type: 2x3 fixed multipaned steel window flanked by 1x3 multipaned steel casements. Concrete sill and spandrel also illustrated. Building 43, facing east - Harbor Hills Housing Project, 26607 Western Avenue, Lomita, Los Angeles County, CA

  20. Window type: 4x4 multipaned steel window flanked by 1x4 multipaned ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Window type: 4x4 multipaned steel window flanked by 1x4 multipaned steel, casements. Concrete stoop, entry overhang and pipe rail detail also illustrated. Building 36, facing northwest - Harbor Hills Housing Project, 26607 Western Avenue, Lomita, Los Angeles County, CA

  1. A Development of Learning Widget on M-Learning and E-Learning Environments

    ERIC Educational Resources Information Center

    Kim, SooHwan; Kim, HyeonCheol; Han, SeonKwan

    2013-01-01

    This article describes the development of learning widget on m-learning and e-learning environments. A widget is a small, simple and useful application supporting user-oriented contents. The user may select and install widgets that are convenient as well as an auto-updating application including weather or calendar. These widgets are especially…

  2. Window type: paired 3x2 multipaned steel window flanked by 1x3 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Window type: paired 3x2 multipaned steel window flanked by 1x3 multipaned steel casements, breaking building corner. Broad overhanging eave also illustrated. Second story detail. Building 13, facing east - Harbor Hills Housing Project, 26607 Western Avenue, Lomita, Los Angeles County, CA

  3. Window type: paired 2x4 multipaned steel windows flanked by 1x4 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Window type: paired 2x4 multipaned steel windows flanked by 1x4 multipaned steel casements, breaking building corner. Raised panel door front entry also illustrated. Ground floor detail Building 19, facing north - Harbor Hills Housing Project, 26607 Western Avenue, Lomita, Los Angeles County, CA

  4. Widget, Widget on the Wall, Am I Performing Well at All?

    ERIC Educational Resources Information Center

    Scheffel, Maren; Drachsler, Hendrik; de Kraker, Joop

    2017-01-01

    In collaborative learning environments, students work together on assignments in virtual teams and depend on each other's contribution to achieve their learning objectives. The online learning environment, however, may not only facilitate but also hamper group communication, coordination, and collaboration. Group awareness widgets that visualize…

  5. An Introduction to X Window Application Development

    DTIC Science & Technology

    1992-03-23

    Acquisition and Policy Evaluation program using Cognitive Feed- back ( ESKAPE /CF) from the SunView windowing system to X Window. The new application...the generic X Window System. This thesis converts an Expert System Knowledge Acquisition and Policy Evaluation program using Cognitive Feedback ( ESKAPE ...15 IV. XESKAPE/CF: THE X WINDOW VERSION OF ESKAPE /CF ........................ 16 A. FUNCTIONAL COMPARISON TO

  6. Environmental Dataset Gateway (EDG) Search Widget

    EPA Pesticide Factsheets

    Use the Environmental Dataset Gateway (EDG) to find and access EPA's environmental resources. Many options are available for easily reusing EDG content in other other applications. This allows individuals to provide direct access to EPA's metadata outside the EDG interface. The EDG Search Widget makes it possible to search the EDG from another web page or application. The search widget can be included on your website by simply inserting one or two lines of code. Users can type a search term or lucene search query in the search field and retrieve a pop-up list of records that match that search.

  7. Continuation of research into software for space operations support, volume 1

    NASA Technical Reports Server (NTRS)

    Collier, Mark D.; Killough, Ronnie; Martin, Nancy L.

    1990-01-01

    A prototype workstation executive called the Hardware Independent Software Development Environment (HISDE) was developed. Software technologies relevant to workstation executives were researched and evaluated and HISDE was used as a test bed for prototyping efforts. New X Windows software concepts and technology were introduced into workstation executives and related applications. The four research efforts performed included: (1) Research into the usability and efficiency of Motif (an X Windows based graphic user interface) which consisted of converting the existing Athena widget based HISDE user interface to Motif demonstrating the usability of Motif and providing insight into the level of effort required to translate an application from widget to another; (2) Prototype a real time data display widget which consisted of research methods for and prototyping the selected method of displaying textual values in an efficient manner; (3) X Windows performance evaluation which consisted of a series of performance measurements which demonstrated the ability of low level X Windows to display textural information; (4) Convert the Display Manager to X Window/Motif which is the application used by NASA for data display during operational mode.

  8. Achieving Information Dominance: Unleashing the Ozone Widget Framework

    DTIC Science & Technology

    2014-06-01

    1 19 th ICCRTS “C2 Agility: Lessons Learned From Research and Operations” For the paper titled: Achieving Information Dominance : Unleashing...00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE Achieving Information Dominance : Unleashing the Ozone Widget Framework 5a. CONTRACT NUMBER 5b...Abstract for Achieving Information Dominance : Unleashing the Ozone Widget Framework One of the key lessons learned from analysis of Joint operations

  9. Configuring Eclipse for GMAT Builds: Instructions for Windows Users, Rev. 0.3

    NASA Technical Reports Server (NTRS)

    Conway, Darrel J.

    2007-01-01

    This document provides instructions about how to configure the Eclipse IDE to build GMAT on Windows based PCs. The current instructions are preliminary; the Windows builds using Eclipse are currently a bit crude. These instructions are intended to give you enough information to get Eclipse setup to build wxWidgets based executables in general, and GMAT in particular.

  10. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets.

    PubMed

    Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek; Colvin, James M

    2012-01-01

    A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.

  11. Comparison of transhumeral socket designs utilizing patient assessment and in vivo skeletal and socket motion tracking: a case study.

    PubMed

    Resnik, Linda; Patel, Tarpit; Cooney, Shane G; Crisco, Joseph J; Fantini, Christopher

    2016-01-01

    This case study compares the impact of two prosthetic socket designs, a "traditional" transhumeral (TH) socket design and a Compression Released Stabilized (CRS) socket. A CRS socket was compared to the existing socket of two persons with transhumeral amputation. Comparisons included assessments of patient comfort and satisfaction with fit, as well as dynamic kinematic assessment using a novel high-speed, high-resolution, bi-plane video radiography system (XROMM, for X-ray Reconstruction of Moving Morphology). Subjects were more satisfied with the comfort of the traditional sockets, although they had positive impressions about aspects of the fit and style of the CRS socket, and thought that it provided better control. Dynamic kinematic assessment revealed that the CRS socket provided better control of the residual limb within the socket, and had less slippage as compared to a traditional TH socket design. The TH CRS socket provided better control of the residual limb within the socket, and had less slippage. However, participants were less satisfied with the comfort and overall utility of the CRS socket, and stated that additional fitting visits/modifications to the CRS socket were needed. It is possible that satisfaction with the CRS socket may have improved with prosthetic adjustment and more acclimation time. Implications for Rehabilitation A comfortable, good fitting prosthetic socket is the key factor in determining how long (or if) an upper limb amputee can tolerate wearing a prosthesis. This case series was a comparison of two socket designs, a 'traditional' socket design and a Compression Released Stabilized (CRS) socket design in persons with transhumeral amputation. The CRS socket provided better control of the residual limb within the socket, and had less slippage. However, its tightness made it more difficult to don. Both subjects were less satisfied with the comfort and overall utility of the CRS socket. However, satisfaction might have been improved

  12. Calibration data Analysis Package (CAP): An IDL based widget application for analysis of X-ray calibration data

    NASA Astrophysics Data System (ADS)

    Vaishali, S.; Narendranath, S.; Sreekumar, P.

    An IDL (interactive data language) based widget application developed for the calibration of C1XS (Narendranath et al., 2010) instrument on Chandrayaan-1 is modified to provide a generic package for the analysis of data from x-ray detectors. The package supports files in ascii as well as FITS format. Data can be fitted with a list of inbuilt functions to derive the spectral redistribution function (SRF). We have incorporated functions such as `HYPERMET' (Philips & Marlow 1976) including non Gaussian components in the SRF such as low energy tail, low energy shelf and escape peak. In addition users can incorporate additional models which may be required to model detector specific features. Spectral fits use a routine `mpfit' which uses Leven-Marquardt least squares fitting method. The SRF derived from this tool can be fed into an accompanying program to generate a redistribution matrix file (RMF) compatible with the X-ray spectral analysis package XSPEC. The tool provides a user friendly interface of help to beginners and also provides transparency and advanced features for experts.

  13. Patient-specific interface pressure case study at transradial prosthetic socket: comparison trials between ICRC polypropylene socket and air splint socket.

    PubMed

    Abd Razak, Nasrul A; Abu Osman, Noor A; Ali, Sadeeq A; Gholizadeh, Hossein

    2016-01-15

    While considering how important the interface between the amputees with the prostheses socket, we have carried out research to compare the gradient pressure occur at the interface socket that may lead to the discomforting effects to the user using common ICRC polypropylene socket and air splint socket. Not Applicable SETTING: Not Applicable POPULATION: The subject was a 23 year old who suffered a traumatic defect on the right arm caused by higher electrical volt. F-Socket sensors have been used to measure dynamic socket interface pressure for the transradial amputee wearer during static and dynamic movements. The printed circuit with a thickness of 0.18 mm is equipped between the socket and the surface of the residual limb. Two F-Socket sensor is required to cover the entire socket surface attached to the residual limb. The average of 10 trials made on prosthetic user using both type of sockets for static and dynamic movements was recorded. The pressure gradient shows that the circumference of the socket interface for the ICRC polypropylene socket gives the most pressure distributions to the amputees compared to the pressure gradient for the air splint socket. The pressure gradient for ICRC socket increased consistently when the user makes movements while for the air splint socket remain constantly. The specific interface pressure occur at the socket interface help in determine the comfort and pain of the socket design and improve the correlation between the user and the prosthesis.

  14. bioWidgets: data interaction components for genomics.

    PubMed

    Fischer, S; Crabtree, J; Brunk, B; Gibson, M; Overton, G C

    1999-10-01

    The presentation of genomics data in a perspicuous visual format is critical for its rapid interpretation and validation. Relatively few public database developers have the resources to implement sophisticated front-end user interfaces themselves. Accordingly, these developers would benefit from a reusable toolkit of user interface and data visualization components. We have designed the bioWidget toolkit as a set of JavaBean components. It includes a wide array of user interface components and defines an architecture for assembling applications. The toolkit is founded on established software engineering design patterns and principles, including componentry, Model-View-Controller, factored models and schema neutrality. As a proof of concept, we have used the bioWidget toolkit to create three extendible applications: AnnotView, BlastView and AlignView.

  15. Tensile strength and impact resistance properties of materials used in prosthetic check sockets, copolymer sockets, and definitive laminated sockets.

    PubMed

    Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek M; Colvin, James M

    2011-01-01

    Prosthetic sockets serve as the interface between people with amputations and their prostheses. Although most materials used to make prosthetic sockets have been used for many years, knowledge of these materials' properties is limited, especially after they are subjected to fabrication processes. This study evaluated tensile and impact properties of the current state-of-the-art materials used to fabricate prosthetic check sockets, copolymer sockets, and definitive laminated sockets. Thermolyn Rigid and Orfitrans Stiff check socket materials produced significantly lower tensile strength and impact resistance than polyethylene terephthalate glycol (PETG). Copolymer socket materials exhibited greater resistance to impact forces than the check socket materials but lower tensile strengths than PETG. The heated molding processes, for the check socket and copolymer materials, reduced both tensile strength and elongation at break. Definitive laminated sockets were sorted according to fabrication techniques. Nyglass material had significantly higher elongation, indicating a more ductile material than carbon-based laminations. Carbon sockets with pigmented resin had higher tensile strength and modulus at break than nonpigmented carbon sockets. Elongation at yield and elongation at break were similar for both types of carbon-based laminations. The material properties determined in this study provide a foundation for understanding and improving the quality of prosthetic sockets using current fabrication materials and a basis for evaluating future technologies.

  16. Chat Widgets for Science Libraries

    ERIC Educational Resources Information Center

    Meier, John J.

    2008-01-01

    This paper describes chat widgets, chunks of code that can be embedded on a web site to appear as an instant messaging system, and how they can be used on a science library web site to better serve library users. Interviews were conducted concerning experiences at science and humanities libraries and more similarities than differences were…

  17. MSL's Widgets: Adding Rebustness to Martian Sample Acquisition, Handling, and Processing

    NASA Technical Reports Server (NTRS)

    Roumeliotis, Chris; Kennedy, Brett; Lin, Justin; DeGrosse, Patrick; Cady, Ian; Onufer, Nicholas; Sigel, Deborah; Jandura, Louise; Anderson, Robert; Katz, Ira; hide

    2013-01-01

    Mars Science Laboratory's (MSL) Sample Acquisition Sample Processing and Handling (SA-SPaH) system is one of the most ambitious terrain interaction and manipulation systems ever built and successfully used outside of planet earth. Mars has a ruthless environment that has surprised many who have tried to explore there. The robustness widget program was implemented by the MSL project to help ensure the SA-SPaH system would be robust enough to the surprises of this ruthless Martian environment. The robustness widget program was an effort of extreme schedule pressure and responsibility, but was accomplished with resounding success. This paper will focus on a behind the scenes look at MSL's robustness widgets: the particle fun zone, the wind guards, and the portioner pokers.

  18. Dry socket

    MedlinePlus

    Alveolar osteitis; Alveolitis; Septic socket ... You may be more at risk for dry socket if you: Have poor oral health Have a ... after having a tooth pulled Have had dry socket in the past Drink from a straw after ...

  19. Cooled window for X-rays or charged particles

    DOEpatents

    Logan, Clinton M.

    1996-01-01

    A window that provides good structural integrity and a very high capacity for removal of the heat deposited by x-rays, electrons, or ions, with minimum attenuation of the desired beam. The window is cooled by providing microchannels therein through which a coolant is pumped. For example, the window may be made of silicon with etched microchannels therein and covered by a silicon member. A window made of silicon with a total thickness of 520 .mu.m transmits 96% of the x-rays at an energy of 60 keV, and the transmission is higher than 90% for higher energy photons.

  20. Interoperability through standardization: Electronic mail, and X Window systems

    NASA Technical Reports Server (NTRS)

    Amin, Ashok T.

    1993-01-01

    Since the introduction of computing machines, there has been continual advances in computer and communication technologies and approaching limits. The user interface has evolved from a row of switches, character based interface using teletype terminals and then video terminals, to present day graphical user interface. It is expected that next significant advances will come in the availability of services, such as electronic mail and directory services, as the standards for applications are developed and in the 'easy to use' interfaces, such as Graphical User Interface for example Window and X Window, which are being standardized. Various proprietary electronic mail (email) systems are in use within organizations at each center of NASA. Each system provides email services to users within an organization, however the support for email services across organizations and across centers exists at centers to a varying degree and is often easy to use. A recent NASA email initiative is intended 'to provide a simple way to send email across organizational boundaries without disruption of installed base.' The initiative calls for integration of existing organizational email systems through gateways connected by a message switch, supporting X.400 and SMTP protocols, to create a NASA wide email system and for implementation of NASA wide email directory services based on OSI standard X.500. A brief overview of MSFC efforts as a part of this initiative are described. Window based graphical user interfaces make computers easy to use. X window protocol has been developed at Massachusetts Institute of Technology in 1984/1985 to provide uniform window based interface in a distributed computing environment with heterogenous computers. It has since become a standard supported by a number of major manufacturers. Z Windows systems, terminals and workstations, and X Window applications are becoming available. However impact of its use in the Local Area Network environment on the network

  1. Socket preservation.

    PubMed

    Fee, L

    2017-04-21

    Socket preservation maintains bone volume post-extraction in anticipation of an implant placement or fixed partial denture pontic site. This procedure helps compensate for the resorption of the facial bone wall. Socket preservation should be considered when implant placement needs to be delayed for patient or site-related reasons. The ideal healing time before implant placement is six months. Socket preservation can reduce the need for later bone augmentation. By reducing bone resorption and accelerating bone formation it increases implant success and survival. Biomaterials for socket grafting including autograft, allograft, xenograft and alloplast. A bone substitute with a low substitution rate is recommended.

  2. Effects of Socket Size on Metrics of Socket Fit in Trans-Tibial Prosthesis Users

    PubMed Central

    Sanders, Joan E; Youngblood, Robert T; Hafner, Brian J; Cagle, John C; McLean, Jake B; Redd, Christian B; Dietrich, Colin R; Ciol, Marcia A; Allyn, Katheryn J

    2017-01-01

    The purpose of this research was to conduct a preliminary effort to identify quantitative metrics to distinguish a good socket from an oversized socket in people with trans-tibial amputation. Results could be used to inform clinical practices related to socket replacement. A cross-over study was conducted on community ambulators (K-level 3 or 4) with good residual limb sensation. Participants were each provided with two sockets, a duplicate of their as-prescribed socket and a modified socket that was enlarged or reduced by 1.8 mm (~6% of the socket volume) based on the fit quality of the as-prescribed socket. The two sockets were termed a larger socket and a smaller socket. Activity was monitored while participants wore each socket for 4wk. Participants’ gait; self-reported satisfaction, quality of fit, and performance; socket comfort; and morning-to-afternoon limb fluid volume changes were assessed. Visual analysis of plots and estimated effect sizes (measure as mean difference divided by standard deviation) showed largest effects for step time asymmetry, step width asymmetry, anterior and anterior-distal morning-to-afternoon fluid volume change, socket comfort scores, and self-reported measures of utility, satisfaction, and residual limb health. These variables may be viable metrics for early detection of deterioration in socket fit, and should be tested in a larger clinical study. PMID:28373013

  3. Effects of socket size on metrics of socket fit in trans-tibial prosthesis users.

    PubMed

    Sanders, Joan E; Youngblood, Robert T; Hafner, Brian J; Cagle, John C; McLean, Jake B; Redd, Christian B; Dietrich, Colin R; Ciol, Marcia A; Allyn, Katheryn J

    2017-06-01

    The purpose of this research was to conduct a preliminary effort to identify quantitative metrics to distinguish a good socket from an oversized socket in people with trans-tibial amputation. Results could be used to inform clinical practices related to socket replacement. A cross-over study was conducted on community ambulators (K-level 3 or 4) with good residual limb sensation. Participants were each provided with two sockets, a duplicate of their as-prescribed socket and a modified socket that was enlarged or reduced by 1.8mm (∼6% of the socket volume) based on the fit quality of the as-prescribed socket. The two sockets were termed a larger socket and a smaller socket. Activity was monitored while participants wore each socket for 4 weeks. Participants' gait; self-reported satisfaction, quality of fit, and performance; socket comfort; and morning-to-afternoon limb fluid volume changes were assessed. Visual analysis of plots and estimated effect sizes (measured as mean difference divided by standard deviation) showed largest effects for step time asymmetry, step width asymmetry, anterior and anterior-distal morning-to-afternoon fluid volume change, socket comfort score, and self-reported utility. These variables may be viable metrics for early detection of deterioration in socket fit, and should be tested in a larger clinical study. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Modular socket system versus traditionally laminated socket: a cost analysis.

    PubMed

    Normann, Elna; Olsson, Anna; Brodtkorb, Thor-Henrik

    2011-03-01

    Using the new modular socket system (MSS) to produce a prosthetic socket directly on the patient has the potential of being easier and quicker to manufacture but also incurring higher costs. The purpose of the study was to compare the costs of manufacturing a transtibial prosthetic socket using either a MSS or a standard laminated socket (PC). Concurrent controlled trial. A total of 20 patients at two orthopaedic facilities were followed with regards to the cost of manufacturing a prosthetic socket using either MSS or PC. Time aspects and material costs were considered in the cost analysis. Other factors studied include delivery time and number of visits. For the cost analysis, only direct costs pertaining to the prosthetic socket were considered. The total cost of MSS was found to be significantly higher (p < 0.01) compared to PC. However, the production and time cost was significantly lower. Delivery time to the patient was 1 day for MSS compared to 17 days for PC. Our study shows that the direct prosthetic cost of treating a patient using MSS is significantly higher than treating a patient using PC. However, the MSS prosthesis can be delivered significantly faster and with fewer visits. Further studies taking the full societal costs of MSS into account should therefore be performed. This study shows that the direct prosthetic cost of treating a patient with Modular Socket System is significantly higher than treating a patient with plastercasting with standard laminated socket. However, the Modular Socket System prosthesis can be delivered significantly faster and with fewer visits.

  5. Electrical grounding prong socket

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leong, R.

    1989-09-12

    This paper describes a socket for a grounding prong used in a three prong electrical plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. 11 figs.

  6. Ada To X-Window Bindings

    NASA Technical Reports Server (NTRS)

    Souleles, Dean

    1993-01-01

    Ada to X-Window Bindings computer program developed to provide Ada programmers with complete interfaces to Xt Intrinsics and OSF Motif toolkits. Provides "Ada view" of some mostly C-language programming libraries. Package of software written in Ada and C languages.

  7. Electrical grounding prong socket

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leong, R.

    1990-01-01

    The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. 17 figs.

  8. Electrical grounding prong socket

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leong, R.

    1990-12-31

    The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. 17 figs.

  9. Electrical grounding prong socket

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leong, R.

    1991-06-18

    This patent describes a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket.

  10. Electrical grounding prong socket

    DOEpatents

    Leong, Robert

    1991-01-01

    The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket.

  11. [The effect of osteogenic inducer on healing of tooth extraction sockets].

    PubMed

    Chen, Junliang; Shan, Chuncheng; He, Yun; Xia, Delin

    2012-06-01

    To study the effect of osteogenic inducer (dexamethasone, beta-sodium glycerophosphate and Vitamin C) carried by gelatin sponge on healing and remodeling of tooth extraction sockets. Fifty rabbits were selected. After extracting the first premolars of bilateral maxillary, the right side tooth extraction sockets were filled with gelatin sponge containing osteogenic inducer as experimental side, tooth extraction sockets on left side were filled with gelatin sponge as control. Every ten rabbits were executed at the end of 1, 2, 4, 8, 12 weeks after tooth extraction. Bone density was measured through digital X-ray images. The specimens were examined by histology. The absorption height of alveolar bone at 12 weeks was measured. X-ray measurement showed that the bone density of experimental side was higher than that of control side at 2, 4, 8, 12 weeks, the difference had statistical significance (P<0.01). The histology examination showed that new bone formation in tooth extraction sockets of experimental side was earlier than that in control side. The absorptional height of alveolar bone had significant difference between experimental side and control side (P<0.01), of which experimental side was less. Filling the osteogenic inducer in tooth extraction sockets can promote the healing and new bone formation and prevent from alveolar bone absorption.

  12. A world-to-chip socket for microfluidic prototype development.

    PubMed

    Yang, Zhen; Maeda, Ryutaro

    2002-10-01

    We report a prototype for a standard connector between a microfluidic chip and the macroworld. This prototype is the first to demonstrate a fully functioning socket for a microchip to access the outside world by means of fluids, data, and energy supply, as well as providing process visibility. It has 20 channels for the input and output of liquids or gases, as well as compressed air or vacuum lines for pneumatic power lines. It also contains 42 pins for electrical signals and power. All these connections were designed in a planar configuration with linear orthogonal arrays. The vertical space was opened for optical measurement and evaluation. The die (29.1 mm x 27.5 mm x 0.9 mm) can be easily mounted and dismounted from the socket. No adhesives or solders are used at any contact points. The pressure limit for the connection of working fluids was 0.2 MPa and the current limit for the electrical connections was 1 A. This socket supports both serial and parallel processing applications. It exhibits great potential for developing microfluidic systems efficiently.

  13. Instrumented socket inserts for sensing interaction at the limb-socket interface.

    PubMed

    Swanson, Eric C; McLean, Jake B; Allyn, Katheryn J; Redd, Christian B; Sanders, Joan E

    2018-01-01

    The objective of this research was to investigate a strategy for designing and fabricating computer-manufactured socket inserts that were embedded with sensors for field monitoring of limb-socket interactions of prosthetic users. An instrumented insert was fabricated for a single trans-tibial prosthesis user that contained three sensor types (proximity sensor, force sensing resistor, and inductive sensor), and the system was evaluated through a sequence of laboratory clinical tests and two days of field use. During in-lab tests 3 proximity sensors accurately distinguish between don and doff states; 3 of 4 force sensing resistors measured gradual pressure increases as weight-bearing increased; and the inductive sensor indicated that as prosthetic socks were added the limb moved farther out of the socket and pistoning amplitude decreased. Multiple sensor types were necessary in analysis of field collected data to interpret how sock changes affected limb-socket interactions. Instrumented socket inserts, with sensors selected to match clinical questions of interest, have the potential to provide important insights to improve patient care. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Designing a Site to Embed and to Interact with Wolfram Alpha Widgets in Math and Sciences Courses

    ERIC Educational Resources Information Center

    Cepeda, Francisco Javier Delgado; Acosta, Ruben Dario Santiago

    2014-01-01

    This paper reports design and implementation outcomes at middle development advance of an educative program based on use and construction of widgets on Wolfram Alpha platform at higher education level for engineering and sciences areas. Widgets were based on Physics and Mathematics curricula under Project Oriented Learning and Blended Learning…

  15. Tethering sockets and wrenches

    NASA Technical Reports Server (NTRS)

    Johnson, E. P.

    1990-01-01

    The tethering of sockets and wrenches was accomplished to improve the safety of working over motor segments. To accomplish the tethering of the sockets to the ratchets, a special design was implemented in which a groove was machined into each socket. Each socket was then fitted with a snap ring that can spin around the machined groove. The snap ring is tethered to the handle of the ratchet. All open end wrenches are also tethered to the ratchet or to the operator, depending upon the type. Tests were run to ensure that the modified tools meet torque requirements. The design was subsequently approved by Space Safety.

  16. Designing the Widget: A Group Decision and Negotiation Task

    ERIC Educational Resources Information Center

    Delise, Lisa A.; Mello, Abby L.

    2017-01-01

    The Widget design task is an in-class, experiential exercise that affords students the opportunity to develop interpersonal skills in group negotiation. Students engage in new product design in committees of two dyads where one dyad represents Consumer Research and the other represents Strategic Management. Task information creates different…

  17. SSL - THE SIMPLE SOCKETS LIBRARY

    NASA Technical Reports Server (NTRS)

    Campbell, C. E.

    1994-01-01

    The Simple Sockets Library (SSL) allows C programmers to develop systems of cooperating programs using Berkeley streaming Sockets running under the TCP/IP protocol over Ethernet. The SSL provides a simple way to move information between programs running on the same or different machines and does so with little overhead. The SSL can create three types of Sockets: namely a server, a client, and an accept Socket. The SSL's Sockets are designed to be used in a fashion reminiscent of the use of FILE pointers so that a C programmer who is familiar with reading and writing files will immediately feel comfortable with reading and writing with Sockets. The SSL consists of three parts: the library, PortMaster, and utilities. The user of the SSL accesses it by linking programs to the SSL library. The PortMaster initializes connections between clients and servers. The PortMaster also supports a "firewall" facility to keep out socket requests from unapproved machines. The "firewall" is a file which contains Internet addresses for all approved machines. There are three utilities provided with the SSL. SKTDBG can be used to debug programs that make use of the SSL. SPMTABLE lists the servers and port numbers on requested machine(s). SRMSRVR tells the PortMaster to forcibly remove a server name from its list. The package also includes two example programs: multiskt.c, which makes multiple accepts on one server, and sktpoll.c, which repeatedly attempts to connect a client to some server at one second intervals. SSL is a machine independent library written in the C-language for computers connected via Ethernet using the TCP/IP protocol. It has been successfully compiled and implemented on a variety of platforms, including Sun series computers running SunOS, DEC VAX series computers running VMS, SGI computers running IRIX, DECstations running ULTRIX, DEC alpha AXPs running OSF/1, IBM RS/6000 computers running AIX, IBM PC and compatibles running BSD/386 UNIX and HP Apollo 3000

  18. Data Transfer Efficiency Over Satellite Circuits Using a Multi-Socket Extension to the File Transfer Protocol (FTP)

    NASA Technical Reports Server (NTRS)

    Allman, Mark; Ostermann, Shawn; Kruse, Hans

    1996-01-01

    In several experiments using NASA's Advanced Communications Technology Satellite (ACTS), investigators have reported disappointing throughput using the transmission control protocol/Internet protocol (TCP/IP) protocol suite over 1.536Mbit/sec (T1) satellite circuits. A detailed analysis of file transfer protocol (FTP) file transfers reveals that both the TCP window size and the TCP 'slow starter' algorithm contribute to the observed limits in throughput. In this paper we summarize the experimental and and theoretical analysis of the throughput limit imposed by TCP on the satellite circuit. We then discuss in detail the implementation of a multi-socket FTP, XFTP client and server. XFTP has been tested using the ACTS system. Finally, we discuss a preliminary set of tests on a link with non-zero bit error rates. XFTP shows promising performance under these conditions, suggesting the possibility that a multi-socket application may be less effected by bit errors than a single, large-window TCP connection.

  19. Socket welds in nuclear facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, P.A.; Torres, L.L.

    1995-12-31

    Socket welds are easier and faster to make than are butt welds. However, they are often not used in nuclear facilities because the crevices between the pipes and the socket sleeves may be subject to crevice corrosion. If socket welds can be qualified for wider use in facilities that process nuclear materials, the radiation exposures to welders can be significantly reduced. The current tests at the Idaho Chemical Processing Plant (ICPP) are designed to determine if socket welds can be qualified for use in the waste processing system at a nuclear fuel processing plant.

  20. Socket stars: UBVRJIK radial profiles

    NASA Astrophysics Data System (ADS)

    Schaefer, Bradley E.

    1995-05-01

    Visual inspectin of stars embedded in H II nebulae has shown a significant fraction to be surrounded by nearly symmetric extended regions within which the nebular brightness is apparently significantly fainter than is typical for the surrounding area. These 'socket stars' might be caused by a bubble in the nebula blown out by a stellar wind or they might be caused by a circumstellar envelope of dust hiding the emission behind the star. As such, the sockets could be the first manifestation of a previously unknown component of pre-main-sequence stars. Unfortunately, no quantitative proof of the existence of sockets has been presented. To fill this need, I have imaged 10 socket stars and six background stars with CCD cameras and infrared array cameras. From these images, I have constructed radial plots which should reveal dips in brightness immediately outside the seeing disk. The radial plots do not show any evidence for the existence of sockets. A detailed examination of the photographs orginally used to identify the sockets show that the causes of these reports are (1) artifacts resulting from the photographic process of dodging and (2) random coincidence of stars with local minima in nebular brightness. Thus, I conclude that 'socket stars' do not exist.

  1. Dry Socket Etiology, Diagnosis, and Clinical Treatment Techniques.

    PubMed

    Mamoun, John

    2018-04-01

    Dry socket, also termed fibrinolytic osteitis or alveolar osteitis, is a complication of tooth exodontia. A dry socket lesion is a post-extraction socket that exhibits exposed bone that is not covered by a blood clot or healing epithelium and exists inside or around the perimeter of the socket or alveolus for days after the extraction procedure. This article describes dry socket lesions; reviews the basic clinical techniques of treating different manifestations of dry socket lesions; and shows how microscope level loupe magnification of 6× to 8× or greater, combined with co-axial illumination or a dental operating microscope, facilitate more precise treatment of dry socket lesions. The author examines the scientific validity of the proposed causes of dry socket lesions (such as bacteria, inflammation, fibrinolysis, or traumatic extractions) and the scientific validity of different terminologies used to describe dry socket lesions. This article also presents an alternative model of what causes dry socket lesions, based on evidence from dental literature. Although the clinical techniques for treating dry socket lesions seem empirically correct, more evidence is required to determine the causes of dry socket lesions.

  2. Dry Socket Etiology, Diagnosis, and Clinical Treatment Techniques

    PubMed Central

    2018-01-01

    Dry socket, also termed fibrinolytic osteitis or alveolar osteitis, is a complication of tooth exodontia. A dry socket lesion is a post-extraction socket that exhibits exposed bone that is not covered by a blood clot or healing epithelium and exists inside or around the perimeter of the socket or alveolus for days after the extraction procedure. This article describes dry socket lesions; reviews the basic clinical techniques of treating different manifestations of dry socket lesions; and shows how microscope level loupe magnification of 6× to 8× or greater, combined with co-axial illumination or a dental operating microscope, facilitate more precise treatment of dry socket lesions. The author examines the scientific validity of the proposed causes of dry socket lesions (such as bacteria, inflammation, fibrinolysis, or traumatic extractions) and the scientific validity of different terminologies used to describe dry socket lesions. This article also presents an alternative model of what causes dry socket lesions, based on evidence from dental literature. Although the clinical techniques for treating dry socket lesions seem empirically correct, more evidence is required to determine the causes of dry socket lesions. PMID:29732309

  3. Distributed Software for Observations in the Near Infrared

    NASA Astrophysics Data System (ADS)

    Gavryusev, V.; Baffa, C.; Giani, E.

    We have developed an integrated system that performs astronomical observations in Near Infrared bands operating two-dimensional instruments at the Italian National Infrared Facility's \\htmllink{ARNICA}{http://helios.arcetri.astro.it:/home/idefix/Mosaic/ instr/arnica/arnica.html} and \\htmllink{LONGSP}{http://helios.arcetri.astro.it:/home/idefix/Mosaic/ instr/longsp/longsp.html}. This software consists of several communicating processes, generally executed across a network, as well as on a single computer. The user interface is organized as widget-based X11 client. The interprocess communication is provided by sockets and uses TCP/IP. The processes denoted for control of hardware (telescope and other instruments) should be executed currently on a PC dedicated for this task under DESQview/X, while all other components (user interface, tools for the data analysis, etc.) can also work under UNIX\\@. The hardware independent part of software is based on the Athena Widget Set and is compiled by GNU C to provide maximum portability.

  4. Socket with built-in valves for the interconnection of microfluidic chips to macro constituents.

    PubMed

    Yang, Zhen; Maeda, Ryutaro

    2003-09-26

    This paper reports a prototype for a standard connector between a microfluidic chip and the macro world. This prototype demonstrate a fully functioning socket for a microchip to access the outside world by means of fluids, data signals and energy supply. It supports up to 10 channels for the input and output of liquids or gases, as well as compressed air or vacuum lines for pneumatic power lines. The socket has built-in valves for each flow channel. It also contains 28 pins for the connection of electrical signals and power. Built-in valves make it possible to control the flow in each channel independently. A chip ( 11.0 x 11.0 x 0.9 mm) can be mounted into or dismounted from the socket with one touch. The fluidic connectors of the socket are designed to contact vertically on the top of chip. And the electrical connectors (the spring array) of that physically support the chip and contact lead pads at the bottom of chip. No adhesives or solders are used at any contact points. The pressure limit for the connection of working fluids was 0.2 MPa and the current limit for the electrical connections was 1 A. This socket supports both serial and parallel processing applications. It exhibits great potential for developing microfluidic systems efficiently.

  5. Design, Fabrication and Testing of Multilayer Coated X-Ray Optics for the Water Window Imaging X-Ray Microscope

    NASA Technical Reports Server (NTRS)

    Spencer, Dwight C.

    1996-01-01

    Hoover et. al. built and tested two imaging Schwarzschild multilayer microscopes. These instruments were constructed as prototypes for the "Water Window Imaging X-Ray Microscope," which is a doubly reflecting, multilayer x-ray microscope configured to operate within the "water window." The "water window" is the narrow region of the x-ray spectrum between the K absorption edges of oxygen (lamda = 23.3 Angstroms) and of carbon (lamda = 43.62 Angstroms), where water is relatively highly transmissive and carbon is highly absorptive. This property of these materials, thus permits the use of high resolution multilayer x-ray microscopes for producing high contrast images of carbon-based structures within the aqueous physiological environments of living cells. We report the design, fabrication and testing of multilayer optics that operate in this regime.

  6. Socket Interface Pressure and Amputee Reported Outcomes for Comfortable and Uncomfortable Conditions of Patellar Tendon Bearing Socket: A Pilot Study.

    PubMed

    Safari, Mohammad Reza; Tafti, Nahid; Aminian, Gholamreza

    2015-01-01

    The objectives of the current study were to compare intra-socket pressure differences between comfortable and uncomfortable socket conditions, and the usefulness of subject perception of satisfaction, activity limitations, and socket comfort in distinguishing between these two socket conditions. Five unilateral trans-tibial amputees took part in the study. They answered the Socket Comfort Score (SCS) and Trinity Amputation and Prosthetic Experience Scale (TAPES) questionnaires before the interface pressure (in standing and walking) was measured for the uncomfortable socket condition at five regions of the residual limb. Participants were then provided with a comfortable socket and wore it for two weeks. Participants who were satisfied with the socket fit after two weeks repeated the SCS and TAPES questionnaires and interface pressure measurements. The differences between the test results of the two conditions were not statistically significant, except for the interface pressure at the popliteal region during the early stance phase, TAPES socket fit subscale, and the SCS. Due to large variability of the data and the lack of statistical significance, no firm conclusion can be made on the possible relationship between the interface pressure values and the patient-reported outcomes of the two socket conditions. A larger sample size and longer acclimation period are required to locate significant differences.

  7. Robot friendly probe and socket assembly

    NASA Technical Reports Server (NTRS)

    Nyberg, Karen L. (Inventor)

    1994-01-01

    A probe and socket assembly for serving as a mechanical interface between structures is presented. The assembly comprises a socket having a housing adapted for connection to a first supporting structure and a probe which is readily connectable to a second structure and is designed to be easily grappled and manipulated by a robotic device for insertion and coupling with the socket. Cooperable automatic locking means are provided on the probe shaft and socket housing for automatically locking the probe in the socket when the probe is inserted a predetermined distance. A second cooperable locking means on the probe shaft and housing are adapted for actuation after the probe has been inserted the predetermined distance. Actuation means mounted on the probe and responsive to the grip of the probe handle by a gripping device, such as a robot for conditioning the probe for insertion and are also responsive to release of the grip of the probe handle to actuate the second locking means to provide a hard lock of the probe in the socket.

  8. Constructing complex graphics applications with CLIPS and the X window system

    NASA Technical Reports Server (NTRS)

    Faul, Ben M.

    1990-01-01

    This article will demonstrate how the artificial intelligence concepts in CLIPS used to solve problems encountered in the design and implementation of graphics applications within the UNIX-X Window System environment. The design of an extended version of CLIPS, called XCLIPS, is presented to show how the X Windows System graphics can be incorporated without losing DOS compatibility. Using XCLIPS, a sample scientific application is built that applies solving capabilities of both two and three dimensional graphics presentations in conjunction with the standard CLIPS features.

  9. Shallow Inferior Conjunctival Fornix in Contracted Socket and Anophthalmic Socket Syndrome: A Novel Technique to Deepen the Fornix Using Fascia Lata Strips

    PubMed Central

    Ibrahiem, Mohamed F. K.; Abdelaziz, Sahar T. A.

    2016-01-01

    Purpose. To evaluate a new surgical technique using fascia lata to deepen the shallow inferior conjunctival fornix in contracted socket and anophthalmic socket syndrome. Methods. A prospective controlled study in which 24 sockets of 24 patients who were unable to wear and retain their ocular prosthesis due to shallow inferior fornix were enrolled and categorized into anophthalmic socket syndromes (9 patients) and contracted sockets (15 patients). Another 24 patients who underwent evisceration or enucleation with healthy sockets and can wear and retain their prosthesis comfortably were chosen as a control group. Deepening of the fornix was performed using fascia lata strips under general anesthesia. Central depth of the inferior fornix was measured preoperatively and postoperatively. Results. A statistically significant improvement of the postoperative central inferior fornix depth was reported which was marked in anophthalmic subgroup. 100% of anophthalmic sockets and 93.3% of contracted sockets achieved satisfactory results during the follow-up period with no postoperative lower eyelid malposition or obvious skin scar. Conclusion. Fascia lata technique is a new alternative and effective procedure to deepen the shallow inferior fornix that can be used in moderate to severe contracted sockets or anophthalmic socket syndrome with minimal lower eyelid or socket complications. PMID:27313868

  10. Shallow Inferior Conjunctival Fornix in Contracted Socket and Anophthalmic Socket Syndrome: A Novel Technique to Deepen the Fornix Using Fascia Lata Strips.

    PubMed

    Ibrahiem, Mohamed F K; Abdelaziz, Sahar T A

    2016-01-01

    Purpose. To evaluate a new surgical technique using fascia lata to deepen the shallow inferior conjunctival fornix in contracted socket and anophthalmic socket syndrome. Methods. A prospective controlled study in which 24 sockets of 24 patients who were unable to wear and retain their ocular prosthesis due to shallow inferior fornix were enrolled and categorized into anophthalmic socket syndromes (9 patients) and contracted sockets (15 patients). Another 24 patients who underwent evisceration or enucleation with healthy sockets and can wear and retain their prosthesis comfortably were chosen as a control group. Deepening of the fornix was performed using fascia lata strips under general anesthesia. Central depth of the inferior fornix was measured preoperatively and postoperatively. Results. A statistically significant improvement of the postoperative central inferior fornix depth was reported which was marked in anophthalmic subgroup. 100% of anophthalmic sockets and 93.3% of contracted sockets achieved satisfactory results during the follow-up period with no postoperative lower eyelid malposition or obvious skin scar. Conclusion. Fascia lata technique is a new alternative and effective procedure to deepen the shallow inferior fornix that can be used in moderate to severe contracted sockets or anophthalmic socket syndrome with minimal lower eyelid or socket complications.

  11. Continuity tester screens out faulty socket connections

    NASA Technical Reports Server (NTRS)

    Golding, G.

    1964-01-01

    A device, used before and after assembly, tests the continuity of an electrical circuit through each pin and socket of multiple connector sockets. Electrically insulated except at the contact area, a test probe is dimensioned to make contact only in properly formed sockets.

  12. Convertible socket for pressure gauge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bissell, R.D.

    1990-01-01

    This patent describes a pressure gauge having a case in which is disposed a Bourdon tube and a base socket connected to the Bourdon tube for placing the tube in pressure communication with a fluid pressure source. Base socket has a rearward face and a bottom face with respect to the gauge adjacent openings defined through the case and an internal passage communication with the tube. It includes means for connecting a source of fluid pressure to the socket selectively through one of the case openings to the bottom face or the rearward face.

  13. Comparison of Rectified and Unrectified Sockets for Transtibial Amputees.

    PubMed

    Engsberg, Jack R; Sprouse, S Wayne; Uhrich, Mary L; Ziegler, Barbara R; Luitjohan, F Daniel

    2008-01-01

    The current method for fabricating prosthetic sockets is to modify a positive mold to account for the non-homogeneity of the residual limb to tolerate load (i.e., rectified socket). We tested unrectified sockets by retaining the shape of the residual limb, except for a distal end pad, using an alginate gel process instead of casting. This investigation compared rectified and unrectified sockets. Forty-three adults with unilateral transtibial amputations were tested after randomly wearing both rectified and unrectified sockets for at least 4 weeks. Testing included a gait analysis, energy expenditure and Prosthesis Evaluation Questionnaire (PEQ). Results indicated no differences between sockets for gait speed and timing, gait kinematics and kinetics, and gait energy expenditure. There were also no differences in the Prosthetic Evaluation Questionnaire and 16 subjects selected the rectified socket, 25 selected the unrectified socket, and 2 subjects selected to use both sockets as their exit socket. Results seemed to indicate that more than one paradigm exists for shaping prosthetic sockets, and this paradigm may be helpful in understanding the mechanisms of socket fit. The alginate gel fabrication method was simpler than the traditional method. The method could be helpful in other countries where prosthetic care is lacking, may be helpful with new amputees, and may be helpful in typical clinics to reduce costs and free the prosthetist to focus more time on patient needs.

  14. Comparison of Rectified and Unrectified Sockets for Transtibial Amputees

    PubMed Central

    Engsberg, Jack R.; Sprouse, S. Wayne; Uhrich, Mary L.; Ziegler, Barbara R.; Luitjohan, F. Daniel

    2008-01-01

    The current method for fabricating prosthetic sockets is to modify a positive mold to account for the non-homogeneity of the residual limb to tolerate load (i.e., rectified socket). We tested unrectified sockets by retaining the shape of the residual limb, except for a distal end pad, using an alginate gel process instead of casting. This investigation compared rectified and unrectified sockets. Forty-three adults with unilateral transtibial amputations were tested after randomly wearing both rectified and unrectified sockets for at least 4 weeks. Testing included a gait analysis, energy expenditure and Prosthesis Evaluation Questionnaire (PEQ). Results indicated no differences between sockets for gait speed and timing, gait kinematics and kinetics, and gait energy expenditure. There were also no differences in the Prosthetic Evaluation Questionnaire and 16 subjects selected the rectified socket, 25 selected the unrectified socket, and 2 subjects selected to use both sockets as their exit socket. Results seemed to indicate that more than one paradigm exists for shaping prosthetic sockets, and this paradigm may be helpful in understanding the mechanisms of socket fit. The alginate gel fabrication method was simpler than the traditional method. The method could be helpful in other countries where prosthetic care is lacking, may be helpful with new amputees, and may be helpful in typical clinics to reduce costs and free the prosthetist to focus more time on patient needs. PMID:18776945

  15. 30 CFR 57.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...

  16. 30 CFR 57.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...

  17. 30 CFR 57.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...

  18. 30 CFR 57.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...

  19. 30 CFR 57.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...

  20. Counter tube window and X-ray fluorescence analyzer study

    NASA Technical Reports Server (NTRS)

    Hertel, R.; Holm, M.

    1973-01-01

    A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.

  1. Snail phenotypic variation and stress proteins: do different heat response strategies contribute to Waddington's widget in field populations?

    PubMed

    Köhler, Heinz-R; Lazzara, Raimondo; Dittbrenner, Nils; Capowiez, Yvan; Mazzia, Christophe; Triebskorn, Rita

    2009-03-15

    On the basis of studies with laboratory strains of Drosophila and Arabidopsis, it has been hypothesized that potential buffers to the expression of phenotypic morphological variation, such as Hsp90 and possibly Hsp70, represent important components of Waddington's widget, which may confer capacitive evolution. As studies on field populations of living organisms to test this hypothesis are lacking, we tested whether a heat response strategy involving high stress protein levels is associated with low morphological variation and vice versa, using four natural populations of Mediterranean pulmonate snails. In response to 8 hr of elevated temperatures, a population of Xeropicta derbentina with uniform shell pigmentation pattern showed remarkably high Hsp70 but low Hsp90 levels. In contrast, a highly variable population of Cernuella virgata kept both Hsp90 and Hsp70 levels low when held at diverse though environmentally relevant temperatures. Two other populations (Theba pisana and another X. derbentina population) with intermediate variation in shell pigmentation pattern were also intermediate in inducing Hsp70, though Hsp90 was maintained at a low level. The observed correlation of stress protein levels and coloration pattern variation provide the first indirect evidence for an association of stress proteins with Waddington's widget under natural conditions.

  2. Thermoelastic Analysis of Hyper-X Camera Windows Suddenly Exposed to Mach 7 Stagnation Aerothermal Shock

    NASA Technical Reports Server (NTRS)

    Ko, William L.; Gong, Leslie

    2000-01-01

    To visually record the initial free flight event of the Hyper-X research flight vehicle immediately after separation from the Pegasus(registered) booster rocket, a video camera was mounted on the bulkhead of the adapter through which Hyper-X rides on Pegasus. The video camera was shielded by a protecting camera window made of heat-resistant quartz material. When Hyper-X separates from Pegasus, this camera window will be suddenly exposed to Mach 7 stagnation thermal shock and dynamic pressure loading (aerothermal loading). To examine the structural integrity, thermoelastic analysis was performed, and the stress distributions in the camera windows were calculated. The critical stress point where the tensile stress reaches a maximum value for each camera window was identified, and the maximum tensile stress level at that critical point was found to be considerably lower than the tensile failure stress of the camera window material.

  3. Prevention and treatment of dry socket.

    PubMed

    Dodson, Tom

    2013-03-01

    Cochrane Oral Health Group Trials Register, Cochrane Central Register of Controlled Trials (CENTRAL), Medline and Embase databases were searched together with reference lists of identified articles. Topic experts and organisations were also contacted. Only randomised controlled trials were considered and there were no restrictions regarding language or date of publication. Data abstraction and risk of bias assessment were conducted in duplicate and Cochrane statistical guidelines were followed. The GRADE tool was used to assess the quality of the body of evidence. Twenty-one trials with 2570 participants were included. Eighteen trials (2376 participants) related to prevention and three to treatment (194 participants). Six studies were at high risk of bias, 14 of unclear risk and one study at low risk. There was moderate evidence (four trials, 750 participants) that chlorhexidine mouthrinses (0.12% and 0.2% concentrations) both before and after extraction(s) prevented approximately 42% of dry socket(s) with a RR of 0.58 (95% CI 0.43 to 0.78; P < 0.001). The number of patients needed to be treated (0.12% and 0.2%) with chlorhexidine rinse to prevent one patient having dry socket (NNT) was 232 (95% CI 176 to 417), 47 (95% CI 35 to 84) and 8 (95% CI 6 to 14) at prevalences of dry socket of 1%, 5% and 30% respectively. Thee was moderate evidence (two trials, in 133 participants) that placing chlorhexidine gel (0.2%) after extractions prevented approximately 58% of dry socket(s) with a RR of 0.42 (95% CI 0.21 to 0.87; P = 0.02) with NNT of 173 (95% CI 127 to 770), 35 (95% CI 25 to 154) and 6 (95% CI 5 to 26) at prevalences of dry socket of 1%, 5% and 30% respectively. There was insufficient evidence to determine the effects of other intrasocket preventive interventions or interventions to treat dry socket. There is some evidence that rinsing with chlorhexidine (0.12% and 0.2%) or placing chlorhexidine gel (0.2%) in the sockets of extracted teeth, provides a benefit in

  4. Dry socket: incidence, clinical features, and predisposing factors.

    PubMed

    Akinbami, Babatunde O; Godspower, Thikan

    2014-01-01

    Background. Dry socket is a global phenomenon. The purpose of the study was to investigate the incidence of dry socket in recent times in a Nigerian Tertiary Hospital. Methods. Patients who were referred for dental extractions were included in the study. The case files of patients were obtained and information retrieved included biodata, indication for extraction, number and type of teeth extracted, oral hygiene status, compliance to oral hygiene instructions, and development of dry socket. Results. One thousand, one hundred and eighty two patients with total of 1362 teeth extracted during the 4-year period of the study were analyzed, out of which 1.4% teeth developed dry socket. The mean age (SD) was 35.2 (16.0) years. Most of the patients who presented with dry socket were in the fourth decade of life. Mandibular teeth were affected more than maxillary teeth. Molars were more affected. Retained roots and third molars were conspicuous in the cases with dry socket. Conclusion. The incidence of dry socket in our centre was lower than previous reports. Oral hygiene status, lower teeth, and female gender were significantly associated with development of dry socket. Treatment with normal saline irrigation and ZnO eugenol dressings allowed relief of the symptoms.

  5. Dry Socket: Incidence, Clinical Features, and Predisposing Factors

    PubMed Central

    Akinbami, Babatunde O.; Godspower, Thikan

    2014-01-01

    Background. Dry socket is a global phenomenon. The purpose of the study was to investigate the incidence of dry socket in recent times in a Nigerian Tertiary Hospital. Methods. Patients who were referred for dental extractions were included in the study. The case files of patients were obtained and information retrieved included biodata, indication for extraction, number and type of teeth extracted, oral hygiene status, compliance to oral hygiene instructions, and development of dry socket. Results. One thousand, one hundred and eighty two patients with total of 1362 teeth extracted during the 4-year period of the study were analyzed, out of which 1.4% teeth developed dry socket. The mean age (SD) was 35.2 (16.0) years. Most of the patients who presented with dry socket were in the fourth decade of life. Mandibular teeth were affected more than maxillary teeth. Molars were more affected. Retained roots and third molars were conspicuous in the cases with dry socket. Conclusion. The incidence of dry socket in our centre was lower than previous reports. Oral hygiene status, lower teeth, and female gender were significantly associated with development of dry socket. Treatment with normal saline irrigation and ZnO eugenol dressings allowed relief of the symptoms. PMID:24987419

  6. Single-Rooted Extraction Sockets: Classification and Treatment Protocol.

    PubMed

    El Chaar, Edgar; Oshman, Sarah; Fallah Abed, Pooria

    2016-09-01

    Clinicians have many treatment techniques from which to choose when extracting a failing tooth and replacing it with an implant-supported restoration and when successful management of an extraction socket during the course of tooth replacement is necessary to achieve predictable and esthetic outcomes. This article presents a straightforward, yet thorough, classification for extraction sockets of single-rooted teeth and provides guidance to clinicians in the selection of appropriate and predictable treatment. The presented classification of extraction sockets for single-rooted teeth focuses on the topography of the extraction socket, while the protocol for treatment of each socket type factors in the shape of the remaining bone, the biotype, and the location of the socket whether it be in the mandible or maxilla. This system is based on the biologic foundations of wound healing and can help guide clinicians to successful treatment outcomes.

  7. Design of a novel prosthetic socket: assessment of the thermal performance.

    PubMed

    Webber, Christina M; Davis, Brian L

    2015-05-01

    Prosthetic liners and sockets insulate the residual limb, causing excessive sweating and concomitant skin maceration. When coupled with atypical loading conditions, further dermatologic problems can arise. This can significantly reduce the quality of life of an amputee patient. Improving the design of the prosthetic socket has been proposed as a means of reestablishing a normal thermal environment around the residual limb. In this study, a prosthetic socket was modified by incorporating a helical cooling channel within the socket wall using additive manufacturing techniques. Two sockets were modeled: a control socket, and a modified socket containing a 0.48 cm diameter cooling channel. Computer simulations and bench-top testing were used to assess the design's ability to create a greater temperature differential across the socket wall. A greater temperature drop across the socket wall suggested that the socket could provide cooling benefits to the residual limb by allowing for heat to be drawn away from the limb. The temperature difference across the socket wall was calculated for both sockets in each aspect of the study. Both socket type (p=0.002) and location on the socket (p=0.014) were statistically significant factors affecting the temperature difference between inner and outer socket walls. Compared with the control socket, the modified socket containing a helical cooling channel exhibited greater temperature differences across its wall of 11.1 °C and 6.4 °C in the computer simulations and bench-top testing, respectively. This finding suggested that socket modifications, such as the cooling channel presented, could provide a beneficial cooling effect to an amputee patient's residual limb. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Flash water-window x-ray generator with a ferrite capillary

    NASA Astrophysics Data System (ADS)

    Sato, Eiichi; Sagae, Michiaki; Ichimaru, Toshio; Takayama, Kazuyoshi; Sakamaki, Kimio; Tamakawa, Yoshiharu

    1997-12-01

    The fundamental study on a flash water-window x-ray generator is described. This generator is composed of a high-voltage power supply, a polarity-inversion high-voltage pulser, a krytron pulser as a trigger device, an oil-diffusion pump, and a vacuum chamber with a capillary. A combined ceramic condenser of about 5 nF in the pulser is charged up to 70 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing a gap switch by the krytron pulser. In the present work, the chamber is evacuated by the pump with a pressure of about 1 by 10-3 Pa, and the titanium anode and cathode electrodes are employed to produce L-series characteristic x rays in the water-window range. The diameter and the length of the ferrite capillary are 2.0 and 30 mm, respectively. Both the cathode voltage and the discharge current displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were minus 24 kV and 2.8 kA, respectively. The pulse durations of the water-window x-rays were nearly equivalent to those of the damped oscillations of the voltage and current, and their values were less than 10 microseconds.

  9. Computer-socket manufacturing error: How much before it is clinically apparent?

    PubMed Central

    Sanders, Joan E.; Severance, Michael R.; Allyn, Kathryn J.

    2015-01-01

    The purpose of this research was to pursue quality standards for computer-manufacturing of prosthetic sockets for people with transtibial limb loss. Thirty-three duplicates of study participants’ normally used sockets were fabricated using central fabrication facilities. Socket-manufacturing errors were compared with clinical assessments of socket fit. Of the 33 sockets tested, 23 were deemed clinically to need modification. All 13 sockets with mean radial error (MRE) greater than 0.25 mm were clinically unacceptable, and 11 of those were deemed in need of sizing reduction. Of the remaining 20 sockets, 5 sockets with interquartile range (IQR) greater than 0.40 mm were deemed globally or regionally oversized and in need of modification. Of the remaining 15 sockets, 5 sockets with closed contours of elevated surface normal angle error (SNAE) were deemed clinically to need shape modification at those closed contour locations. The remaining 10 sockets were deemed clinically acceptable and not in need modification. MRE, IQR, and SNAE may serve as effective metrics to characterize quality of computer-manufactured prosthetic sockets, helping facilitate the development of quality standards for the socket manufacturing industry. PMID:22773260

  10. Window types: (from left to right) Pair of 2x2 multipaned ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Window types: (from left to right) Pair of 2x2 multipaned steel casements; triplet of 1x4 multipaned steel casements (center panel fixed); 1x3 multipaned steel casements. Building 20, facing southwest - Harbor Hills Housing Project, 26607 Western Avenue, Lomita, Los Angeles County, CA

  11. Moisture permeability of the total surface bearing prosthetic socket with a silicone liner: is it superior to the patella-tendon bearing prosthetic socket?

    PubMed

    Hachisuka, K; Matsushima, Y; Ohmine, S; Shitama, H; Shinkoda, K

    2001-09-01

    The purpose of this study was to examine the moisture permeability properties of materials used for total surface bearing (TSB) socket with a silicone liner, a combination of Silicone Suction Socket or Icelandic Roll-On Silicone Socket (ICEROSS) and an acrylic plastic sheet (Degaplast), patella-tendon bearing (PTB) socket, a combination of Pe-Lite and Degaplast, and wooden socket made of poplar. Moisture permeability of the socket materials was measured as the diminution of water in a container after 12 hours in a climatic chamber. Eight containers with their open, top side were uncovered (no material) or sealed with one of the socket materials; the experiment was repeated four times. One-way analysis of variance followed by Bonferroni's test was applied to examine the differences in moisture permeability. Moisture permeability levels were as follows: no material, 85.9 +/- 1.3 g; poplar, 4.3 +/- 0.4 g; Silicone Suction Socket, 1.1 +/- 0.2 g; ICEROSS, 1.0 +/- 0.2 g; Pe-Lite, 0.8 +/- 0.1 g; 3S + Degaplast, 0.8 +/- 0.1 g; ICEROSS + Degaplast, 0.8 +/- 0.2 g; and Pe-Lite + Degaplast, 0.8 +/- 0.1 g. There were significant differences between the uncovered container and the others, and between poplar and the others (P < 0.05). We concluded that the TSB socket with a silicone liner is not superior to the PTB socket with regard to moisture permeability, and that it is necessary to develop a new prosthetic socket that allows heat release and drainage of sweat.

  12. Fatigue strength of socket welded pipe joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higuchi, Makoto; Hayashi, Makoto; Yamauchi, Takayoshi

    1995-12-01

    Fully reversed four point bending fatigue tests were carried out on small diameter socket welded joints made of carbon steels. Experimental parameters were pipe diameter, thicknesses of pipe and socket wall, throat depth and shape of fillet welds, slip-on and diametral gaps in the socket welding, lack of penetration at the root of fillet welds, and peening of fillet welds. In most cases a fatigue crack started from the root of the fillet, but in the case of higher stress amplitude, it tended to start from the toe of fillet. The standard socket welded joint for a pipe with amore » 50 mm nominal diameter showed a relatively low fatigue strength of 46 MPa in stress amplitude at the 10{sup 7} cycles failure life. This value corresponds to about 1/5 of that for the smoothed base metal specimens in axial fatigue. The fatigue strength decreased with increasing pipe diameter, and increased with increasing thickness of the pipe and socket wall. The effects of throat depth and shape of fillet welds on fatigue strength were not significant. Contrary to expectation, the fatigue strength of a socket welded joint without slip-on gap is Higher than that of the joint with a normal gap. A lack of penetration at the root deleteriously reduced fatigue strength, showing 14 MPa in stress amplitude at the 10{sup 7} cycles failure life for the 50 mm diameter socket joint.« less

  13. Periotest values of implants placed in sockets augmented with calcium phosphosilicate putty graft: a comparative analysis against implants placed in naturally healed sockets.

    PubMed

    Mahesh, Lanka; Narayan, Tv; Kostakis, Georgios; Shukla, Sagrika

    2014-03-01

    To measure implant stability using periotest values of implants placed in sockets augmented with calcium phospho-silicate putty (CPS Putty) as compared with implant stability in naturally healed sockets. Twenty two sockets were implanted with CPS Putty immediately after extraction. The sockets were re-entered after a healing period at 5 to 6 months (average 5.3 months) for implant placement. Periotest values were recorded during implant insertion to assess primary stability. These were compared with the Periotest values of 26 implants placed in 22 patients, with naturally healed sockets. Periotest values were significantly lower in the grafted group, indicating better implant stability in sites grafted with CPS putty. Implant stability seems to be significantly higher in sockets augmented using CPS putty when compared to nongrafted sites. This suggests that socket grafting with CPS putty may enhance the quality of available bone for implantation.

  14. Reusable vibration resistant integrated circuit mounting socket

    DOEpatents

    Evans, Craig N.

    1995-01-01

    This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and holds it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuit lead can be removed from the socket without damage either to the lead or to the socket components.

  15. An assessment technique for computer-socket manufacturing

    PubMed Central

    Sanders, Joan; Severance, Michael

    2015-01-01

    An assessment strategy is presented for testing the quality of carving and forming of individual computer aided manufacturing facilities. The strategy is potentially useful to facilities making sockets and companies marketing manufacturing equipment. To execute the strategy, an evaluator fabricates a collection of test models and sockets using the manufacturing suite under evaluation, and then measures their shapes using scanning equipment. Overall socket quality is assessed by comparing socket shapes with electronic file shapes. Then model shapes are compared with electronic file shapes to characterize carving performance. Socket shapes are compared with model shapes to characterize forming performance. The mean radial error (MRE), which is the average difference in radii between the two shapes being compared, provides insight into sizing quality. Inter-quartile range (IQR), the range of radial error for the best matched half of the points on the surfaces being compared, provides insight into shape quality. By determining MRE and IQR for carving and forming separately, the source(s) of socket shape error may be pinpointed. The developed strategy may provide a useful tool to the prosthetics community and industry to help identify problems and limitations in computer aided manufacturing and insight into appropriate modifications to overcome them. PMID:21938663

  16. Enhanced networks operations using the X Window System

    NASA Technical Reports Server (NTRS)

    Linares, Irving

    1993-01-01

    We propose an X Window Graphical User Interface (GUI) which is tailored to the operations of NASA GSFC's Network Control Center (NCC), the NASA Ground Terminal (NGT), the White Sands Ground Terminal (WSGT), and the Second Tracking and Data Relay Satellite System (TDRSS) Ground Terminal (STGT). The proposed GUI can also be easily extended to other Ground Network (GN) Tracking Stations due to its standardized nature.

  17. Reusable vibration resistant integrated circuit mounting socket

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, C.N.

    1993-12-31

    This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and hold it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuitmore » lead can be removed from the socket without damage either to the lead or to the socket components.« less

  18. Reusable vibration resistant integrated circuit mounting socket

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, C.N.

    1995-08-29

    This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and holds it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuitmore » lead can be removed from the socket without damage either to the lead or to the socket components. 11 figs.« less

  19. Prosthetic limb sockets from plant-based composite materials.

    PubMed

    Campbell, Andrew I; Sexton, Sandra; Schaschke, Carl J; Kinsman, Harry; McLaughlin, Brian; Boyle, Martin

    2012-06-01

    There is a considerable demand for lower limb prostheses globally due to vascular disease, war, conflict, land mines and natural disasters. Conventional composite materials used for prosthetic limb sockets include acrylic resins, glass and carbon fibres, which produce harmful gasses and dust in their manufacture. To investigate the feasibility of using a renewable plant oil-based polycarbonate-polyurethane copolymer resin and plant fibre composite, instead of conventional materials, to improve safety and accessibility of prosthetic limb manufacture. Experimental, bench research. Test pieces of the resin with a range of plant fibres (10.0% by volume) were prepared and tensile strengths were tested. Test sockets of both conventional composite materials and plant resin with plant fibres were constructed and tested to destruction. Combinations of plant resin and either banana or ramie fibres gave high tensile strengths. The conventional composite material socket and plant resin with ramie composite socket failed at a similar loading, exceeding the ISO 10328 standard. Both wall thickness and fibre-matrix adhesion played a significant role in socket strength. From this limited study we conclude that the plant resin and ramie fibre composite socket has the potential to replace the standard layup. Further mechanical and biocompatibility testing as well as a full economic analysis is required. Using readily sourced and renewable natural fibres and a low-volatile bio-resin has potential to reduce harm to those involved in the manufacture of artificial limb sockets, without compromising socket strength and benefitting clinicians working in poorer countries where safety equipment is scarce. Such composite materials will reduce environmental impact.

  20. An open randomized controlled clinical trial to evaluate ridge preservation and repair using SocketKAP(™) and SocketKAGE(™) : part 2 - three-dimensional alveolar bone volumetric analysis of CBCT imaging.

    PubMed

    Abdelhamid, Alaa; Omran, Mostafa; Bakhshalian, Neema; Tarnow, Dennis; Zadeh, Homayoun H

    2016-06-01

    The aims of this study were (i) to evaluate the efficacy of ridge preservation and repair procedures involving the application of SocketKAP(™) and SocketKAGE(™) devices following tooth removal and (ii) to evaluate alveolar bone volumetric changes at 6 months post-extraction in intact sockets or those with facial wall dehiscence defects using 3-dimensional pre- and postoperative CBCT data. Thirty-six patients required 61 teeth extracted. Five cohorts were established: Group A: Intact Socket Negative Control Group B: Intact Socket + SocketKAP(™) Group C: Intact Socket Filled with Anorganic Bovine Bone Mineral (ABBM) + SocketKAP(™) Group D: Facial Dehiscence Socket Negative Control Group E: Facial Dehiscence Socket Filled with ABBM + SocketKAP(™) + SocketKAGE(™) . Preoperative CBCT scans were obtained followed by digital subtraction of the test teeth. At 6 months post-extraction, another CBCT scan was obtained. The pre- and postoperative scans were then superimposed, allowing highly accurate quantitative determination of the 3D volumetric alveolar bone volume changes from baseline through 6 months. Significant volumetric bone loss occurred in all sockets, localized mainly in the 0-3 mm zone apical to the ridge crest. For intact sockets, SocketKAP(™) + ABBM treatment led to a statistically significant greater percentage of remaining mineralized tissue volume when compared to negative control group. A significant difference favoring SocketKAP(™) + SocketKAGE(™) + ABBM treatment was observed for sockets with facial dehiscence defects compared to the negative control group. SocketKAP(™) , with ABBM, appears effective in limiting post-extraction volumetric bone loss in intact sockets, while SocketKAP(™) + SocketKAGE + ABBM appears effective in limiting post-extraction bone loss in sockets with dehiscence defects. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Revisiting "The Widget Effect": Teacher Evaluation Reforms and the Distribution of Teacher Effectiveness

    ERIC Educational Resources Information Center

    Kraft, Matthew A.; Gilmour, Allison F.

    2017-01-01

    In 2009, the New Teacher Project's "The Widget Effect" documented the failure of U.S. public school districts to recognize and act on differences in teacher effectiveness. We revisit these findings by compiling teacher performance ratings across 24 states that adopted major reforms to their teacher evaluation systems. In the vast…

  2. Improved Ball-and-Socket Docking Mechanism

    NASA Technical Reports Server (NTRS)

    Cloyd, Richard; Bryan, Tom

    2004-01-01

    A proposed docking mechanism would form a ball-and-socket joint in the docked condition. The mechanism could tolerate significant initial misalignment because it would include an alignment cone that would guide the ball into the socket. Like other ball-and-socket joints, the joint would have three rotational degrees of freedom. This docking mechanism would be a successor to the one described in Passive Capture Joint With Three Degrees of Freedom (MFS-31146), NASA Tech Briefs, Vol. 22, No. 7 (July 1998), page 65. It would contain most of the components of the prior mechanism, plus some additional components that would expand its capabilities.

  3. [Computerized monitoring system in the operating center with UNIX and X-window].

    PubMed

    Tanaka, Y; Hashimoto, S; Chihara, E; Kinoshita, T; Hirose, M; Nakagawa, M; Murakami, T

    1992-01-01

    We previously reported the fully automated data logging system in the operating center. Presently, we revised the system using a highly integrated operating system, UNIX instead of OS/9. With this multi-task and multi-window (X-window) system, we could monitor all 12 rooms in the operating center at a time. The system in the operating center consists of 2 computers, SONY NEWS1450 (UNIX workstation) and Sord M223 (CP/M, data logger). On the bitmapped display of the workstation, using X-window, the data of all the operating rooms can be visualized. Furthermore, 2 other minicomputers (Fujitsu A50 in the conference room, and A60 in the ICU) and a workstation (Sun3-80 in the ICU) were connected with ethernet. With the remote login function (NFS), we could easily obtain the data during the operation from outside the operating center. This system works automatically and needs no routine maintenance.

  4. A smartphone photogrammetry method for digitizing prosthetic socket interiors.

    PubMed

    Hernandez, Amaia; Lemaire, Edward

    2017-04-01

    Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.

  5. Alveolar socket healing: what can we learn?

    PubMed

    Araújo, Mauricio G; Silva, Cléverson O; Misawa, Mônica; Sukekava, Flavia

    2015-06-01

    Tooth extraction induces a series of complex and integrated local changes within the investing hard and soft tissues. These local alterations arise in order to close the socket wound and to restore tissue homeostasis, and are referred to as '"socket healing". The aims of the present report were twofold: first, to describe the socket-healing process; and, second, to discuss what can be learned from the temporal sequence of healing events, in order to improve treatment outcomes. The socket-healing process may be divided into three sequential, and frequently overlapping, phases: inflammatory; proliferative; and modeling/remodeling. Several clinical and experimental studies have demonstrated that the socket-healing process promotes up to 50% reduction of the original ridge width, greater bone resorption at the buccal aspect than at the lingual/palatal counterpart and a larger amount of alveolar bone reduction in the molar region. In conclusion, tooth extraction, once a simple and straightforward surgical procedure, should be performed in the knowledge that ridge reduction will follow and that further clinical steps should be considered to compensate for this, when considering future options for tooth replacement. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. An open randomized controlled clinical trial to evaluate ridge preservation and repair using SocketKAP(™) and SocketKAGE(™) : part 1-three-dimensional volumetric soft tissue analysis of study casts.

    PubMed

    Zadeh, Homayoun H; Abdelhamid, Alaa; Omran, Mostafa; Bakhshalian, Neema; Tarnow, Dennis

    2016-06-01

    The aims of this study were to evaluate (i) the efficacy of ridge preservation and repair involving SocketKAP(™) and SocketKAGE(™) devices following tooth removal; and (ii) ridge contour changes at 6 months post-extraction in intact sockets and sockets with dehiscence defects. Thirty-six patients required a total of 61 teeth to be extracted. Five cohorts were established with groups A-C involving intact sockets and groups D and E involving facial dehiscence: (A) Negative Control; (B) SocketKAP(™) alone; (C) Anorganic Bovine Bone Mineral (ABBM) + SocketKAP(™) ; (D) Negative Control; and (E) ABBM + SocketKAP(™)  + SocketKAGE(™) . Preoperative CBCT and laser-scanned casts were obtained. Teeth segmented from preoperative CBCT were merged with study cast images to allow for digital removal of teeth from the casts. Volumetric measurements of ridge contour were performed. Images of preoperative and 6 months post-operative casts were superimposed to measure ridge contour changes. Post-extraction contour loss occurred in all sockets primarily in the crestal 3 mm but was also detected up to 6 mm from alveolar crest. For intact sockets, SocketKAP(™) or SocketKAP(™)  + ABBM interventions led to greater percentages of remaining ridge contour when compared to controls. A significant difference favoring SocketKAP(™)  + SocketKAGE(™)  + ABBM treatment was observed for sockets with facial dehiscence when compared to controls. SocketKAP(™) , with or without ABBM, significantly limited post-extraction ridge contour loss in intact sockets. In the absence of a group treated with only the SocketKAGE(™) , it is not possible to determine its efficacy, although the combination of SocketKAGE(™)  + SocketKAP(™)  + ABBM was effective in limiting post-extraction ridge contour loss in sockets with dehiscence defects. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Sockets and Pebbles

    NASA Technical Reports Server (NTRS)

    1997-01-01

    This close-up Sojourner rover image of a small rock shows that weathering has etched-out pebbles to produce sockets. In the image, sunlight is coming from the upper left. Sockets (with shadows on top) are visible at the lower left and pebbles (with bright tops and shadowed bases) are seen at the lower center and lower right. Two pebbles (about 0.5 cm across) are visible at the lower center.

    Mars Pathfinder is the second in NASA's Discovery program of low-cost spacecraft with highly focused science goals. The Jet Propulsion Laboratory, Pasadena, CA, developed and manages the Mars Pathfinder mission for NASA's Office of Space Science, Washington, D.C. JPL is a division of the California Institute of Technology (Caltech).

  8. A sealed titanium window proportional counter for the detection of .5-keV X rays.

    NASA Technical Reports Server (NTRS)

    Mcclintock, J. E.; Levine, A.; Rappaport, S.

    1972-01-01

    A sealed Ti window proportional counter sensitive to X radiation in the energy range 0.35-0.45 keV and above 1.5 keV is described. Measurements of the Ti mass absorption coefficients and a graphical summary of the literature values are presented. For a proportional counter with a 930 microgram/sq cm (2.1-micron) Ti window, the peak efficiency at 0.45 keV is found to lie between 4.6% and 7.1%. An application in X-ray astronomy involving a rocket observation of Sco X-1 is discussed.

  9. Ridge preservation comparing socket allograft alone to socket allograft plus facial overlay xenograft: a clinical and histologic study in humans.

    PubMed

    Poulias, Evmenios; Greenwell, Henry; Hill, Margaret; Morton, Dean; Vidal, Ricardo; Shumway, Brian; Peterson, Thomas L

    2013-11-01

    Previous studies of ridge preservation showed a loss of ≈18% or 1.5 mm of crestal ridge width in spite of treatment. The primary aim of this randomized, controlled, masked clinical trial is to compare a socket graft to the same treatment plus a buccal overlay graft, both with a polylactide membrane, to determine if loss of ridge width can be prevented by use of an overlay graft. Twelve patients who served as positive controls received an intrasocket mineralized cancellous allograft (socket group), and 12 patients received the same socket graft procedure plus buccal overlay cancellous xenograft (overlay group). Horizontal ridge dimensions were measured with a digital caliper, and vertical ridge changes were measured from a stent. Before implant placement, at 4 months, a trephine core was obtained for histologic analysis. The mean horizontal ridge width at the crest for the socket group decreased from 8.7 ± 1.0 to 7.1 ± 1.5 mm for a mean loss of 1.6 ± 0.8 mm (P <0.05), whereas the same measurement for the overlay group decreased from 8.4 ± 1.4 to 8.1 ± 1.4 mm for a mean loss of 0.3 ± 0.9 mm (P >0.05). The overlay group was significantly different from the socket group (P <0.05). Histologic analysis revealed that the socket group had 35% ± 16% vital bone, and the overlay group had 40% ± 16% (P >0.05). The overlay treatment significantly prevented loss of ridge width and preserved or augmented the buccal contour. The socket and overlay groups healed with a high percentage of vital bone.

  10. Systemic review of dry socket: aetiology, treatment, and prevention.

    PubMed

    Tarakji, Bassel; Saleh, Lubna Ahmed; Umair, Ayesha; Azzeghaiby, Saleh Nasser; Hanouneh, Salah

    2015-04-01

    Our systemic review is to make a comprehensive review about the aetiology, treatment and the prevention of dry socket, the inclusion criteria were all the studies that discuss the dry socket and its etiology, treatment and prevention and exclusion criteria were all the studies that discuss the other complications of tooth extraction, the materials and methods used for this systemic review was to search in the Pub Medline database between 2008 to 2013, using specific words "dry socket, aetiology, treatment and prevention" and published in the English language, the articles were screened by abstract for relevance to aetiology, treatment and prevention of dry socket, 82 papers were identified in pub med but a total of 36 out of Publications were included in the final systemic review according to the specific keywords and materials mentioned above. The occurrence of dry socket in an everyday oral surgery or dental practice is unavoidable. The risk factors are smoking, surgical trauma, single extractions, age, sex, medical history, systemic disorder, extraction site, amount of anaesthesia, operator experience, antibiotics use prior to surgery, difficulty of the surgery and the previous surgical site infection in addition to oral Contraceptives, menstrual cycle and immediate postextraction socket irrigation with normal saline. The traditional options of treatment are directed toward palliative care, such as the irrigation of the surgical site, avoiding curetting the extraction socket, Packing with a zinc oxide- eugenol paste on iodoform gauze can be considered to relieve acute pain episodes, there is also new agents in the market can accelerate the healing of the socket such as PRGF and GECB. The prevention methods include avoiding smoking before and after surgery and a traumatic surgery, the use of antibiotics, such as, azithromycin, can be considered, the other preventive measures such as chlorhecidine rinse or gel can be effective in the reduction of dry socket

  11. Systemic Review of Dry Socket: Aetiology, Treatment, and Prevention

    PubMed Central

    Saleh, Lubna Ahmed; Umair, Ayesha; Azzeghaiby, Saleh Nasser; Hanouneh, Salah

    2015-01-01

    Our systemic review is to make a comprehensive review about the aetiology, treatment and the prevention of dry socket, the inclusion criteria were all the studies that discuss the dry socket and its etiology, treatment and prevention and exclusion criteria were all the studies that discuss the other complications of tooth extraction, the materials and methods used for this systemic review was to search in the Pub Medline database between 2008 to 2013, using specific words “dry socket, aetiology, treatment and prevention” and published in the English language, the articles were screened by abstract for relevance to aetiology, treatment and prevention of dry socket, 82 papers were identified in pub med but a total of 36 out of Publications were included in the final systemic review according to the specific keywords and materials mentioned above. The occurrence of dry socket in an everyday oral surgery or dental practice is unavoidable. The risk factors are smoking, surgical trauma, single extractions, age, sex, medical history, systemic disorder, extraction site, amount of anaesthesia, operator experience, antibiotics use prior to surgery, difficulty of the surgery and the previous surgical site infection in addition to oral Contraceptives, menstrual cycle and immediate postextraction socket irrigation with normal saline. The traditional options of treatment are directed toward palliative care, such as the irrigation of the surgical site, avoiding curetting the extraction socket, Packing with a zinc oxide– eugenol paste on iodoform gauze can be considered to relieve acute pain episodes, there is also new agents in the market can accelerate the healing of the socket such as PRGF and GECB. The prevention methods include avoiding smoking before and after surgery and a traumatic surgery, the use of antibiotics, such as, azithromycin, can be considered, the other preventive measures such as chlorhecidine rinse or gel can be effective in the reduction of dry socket

  12. A new directly moulded patellar-tendon-bearing socket.

    PubMed

    Boot, D A; Young, N J

    1985-08-01

    Silicone rubbers and casting tapes individually have previously been used in the manufacture of sockets (Swanson, 1972; Sweitzer, 1973; Ruder, 1977; Graves, 1980; Aqualite, 1982). The authors believe that the present combination of these materials to manufacture a directly moulded socket with a complete silicone rubber lining of variable thickness has not previously been described. The new socket, after addition of the modular components, allows fitting of an aligned below-knee prosthesis within three hours. The socket (Fig. 1.) is made directly on the below-knee stump, can be completed with experience in an hour and does not require the use of specialized equipment. The socket consists of an outer supportive Scotchflex layer inside which is a lining of soft smooth biocompatible silicone rubber of deliberately variable thickness to allow pressure tolerant areas to accept more load and pressure sensitive areas to accept less load (Fig.2). The thicker areas of silicone are produced by applying carefully cut Plastazote pads to the pressure sensitive areas. The thickness and extent of the pads is individually assessed according to the estimated sensitivity of the particular area (Fig. 3). The Scotchflex socket is then manufactured directly on the below-knee stump with these pads applied. The pads are then removed prior to insertion of a semi-liquid silicone rubber. Thus, when the socket with the liquid silicone rubber is re-applied to the stump, the space produced by the pads is filled by the rubber which then sets at room temperature. In this way a layer of variable thickness is produced.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Review of the socket design and interface pressure measurement for transtibial prosthesis.

    PubMed

    Pirouzi, Gh; Abu Osman, N A; Eshraghi, A; Ali, S; Gholizadeh, H; Wan Abas, W A B

    2014-01-01

    Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations.

  14. Sputtered carbon as a corrosion barrier for x-ray detector windows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rowley, Joseph; Pei, Lei; Davis, Robert C., E-mail: davis@byu.edu

    Sputtered amorphous carbon thin films were explored as corrosion resistant coatings on aluminum thin films to be incorporated into x-ray detector windows. The requirements for this application include high corrosion resistance, low intrinsic stress, high strains at failure, and high x-ray transmission. Low temperature sputtering was used because of its compatibility with the rest of the window fabrication process. Corrosion resistance was tested by exposure of carbon coated and uncoated Al thin films to humidity. Substrate curvature and bulge testing measurements were used to determine intrinsic stress and ultimate strain at failure. The composition and bonding of the carbon filmsmore » were further characterized by electron energy loss spectroscopy, Raman spectroscopy, and carbon, hydrogen, and nitrogen elemental analyses. Samples had low compressive stress (down to.08 GPa), a high strain at failure (3%), and a low fraction of sp{sup 3} carbon–carbon bonds (less than 5%). The high breaking strain and excellent x-ray transmission of these sputtered carbon films indicate that they will work well as corrosion barriers in this application.« less

  15. Probe-And-Socket Fasteners For Robotic Assembly

    NASA Technical Reports Server (NTRS)

    Nyberg, Karen

    1995-01-01

    Self-alignment and simplicity of actuation make mechanism amenable to robotic assembly. Includes socket, mounted on structure at worksite, and probe, mounted on piece of equipment to be attached to structure at socket. Probe-and-socket mechanism used in conjunction with fixed target aiding in placement of end effector of robot during grasping, and with handle or handles on structure. Intended to enable robot to set up workstation in hostile environment. Workstation then used by astronaut, aquanaut, or other human, spending minimum time in environment. Human concentrates on performing quality work rather than on setting up equipment, with consequent reduction of risk.

  16. Characterization of Beryllium Windows Using Coherent X-rays at 1-km Beamline

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goto, Shunji; Yabashi, Makina; Takahashi, Sunao

    2004-05-12

    Beryllium windows were characterized using coherent x-rays at the one-kilometer beamline of SPring-8. Non-uniformity of transmission x-ray images is largely due to Fresnel diffraction from deficiencies such as surface pits with diameter of order of one micron to ten microns, having no correlation with averaged surface roughness measured with an optical profilometer.

  17. Fatigue evaluation of socket welded piping in nuclear power plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vecchio, R.S.

    1996-12-01

    Fatigue failures in piping systems occur, almost without exception, at the welded connections. In nuclear power plant systems, such failures occur predominantly at the socket welds of small diameter piping ad fillet attachment welds under high-cycle vibratory conditions. Nearly all socket weld fatigue failures are identified by leaks which, though not high in volume, generally are costly due to attendant radiological contamination. Such fatigue cracking was recently identified in the 3/4 in. diameter recirculation and relief piping socket welds from the reactor coolant system (RCS) charging pumps at a nuclear power plant. Consequently, a fatigue evaluation was performed to determinemore » the cause of cracking and provide an acceptable repair. Socket weld fatigue life was evaluated using S-N type fatigue life curves for welded structures developed by AASHTO and the assessment of an effective cyclic stress range adjacent to each socket weld. Based on the calculated effective tress ranges and assignment of the socket weld details to the appropriate AASHTO S-N curves, the socket weld fatigue lives were calculated and found to be in excellent agreement with the accumulated cyclic life to-date.« less

  18. The Effect of Cancer Therapies on Pediatric Anophthalmic Sockets

    PubMed Central

    Shildkrot, Yevgeniy; Kirzhner, Maria; Haik, Barrett G.; Qaddoumi, Ibrahim; Rodriguez-Galindo, Carlos; Wilson, Matthew W.

    2012-01-01

    Purpose To determine the impact of chemotherapy or external beam radiotherapy (EBRT) on pediatric anophthalmic sockets. Design A retrospective, nonrandomized, interventional cohort study. Participants A total of 135 sockets of 133 children undergoing enucleation from late 1999 to early 2009 at the St. Jude Children’s Research Hospital were included. Methods A retrospective chart review of outcomes after enucleation in patients treated with systemic chemotherapy or orbital EBRT either before or after removal of the eye compared with patients who received no other treatment. Main Outcome Measures Incidence of implant exposure, migration, extrusion, socket contracture, and pyogenic granuloma formation. Results Retinoblastoma was the primary diagnosis in 128 eyes (95%). Median follow-up was 3.6 years (range, 0.1–9.3 years). Event-free course was observed in 94 sockets (69.6%). Complications included implant exposure (n = 28, 20.7%), socket contracture (n = 16, 11.9%), pyogenic granuloma (n = 9, 6.7%), implant extrusion (n = 3, 2.2%), and migration (n = 2, 1.5%). Exposure resolved in 21 sockets (77.8%) and improved in 2 sockets (11.1%); 1 patient with exposure died. Use of prior, adjuvant, or subsequent chemotherapy increased the long-term risk of exposure (odds ratio [OR] = 3.7; 95% confidence interval [CI], 1.4–9.4), and contracture (OR could not be calculated, P<0.0001). External beam radiotherapy greatly increased the risk of contracture (OR 24.0; 95% CI, 6.9–82.8) and exposure (OR 2.89; 95% CI, 1.1–7.9). Conclusions In this unique pediatric population with cancer, chemotherapy and EBRT had an additive effect, significantly increasing the incidence of exposure and socket contracture. PMID:21856015

  19. Review of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis

    PubMed Central

    Pirouzi, Gh.; Abu Osman, N. A.; Eshraghi, A.; Ali, S.; Gholizadeh, H.; Wan Abas, W. A. B.

    2014-01-01

    Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations. PMID:25197716

  20. Design and Evaluation of a Widget-Based Dashboard for Awareness Support in Research Networks

    ERIC Educational Resources Information Center

    Reinhardt, Wolfgang; Mletzko, Christian; Drachsler, Hendrik; Sloep, Peter B.

    2014-01-01

    In this article, we describe the rationale, design and evaluation of a widget-based dashboard to support scholars' awareness of their Research Networks. We introduce the concept of a Research Network and discuss Personal Research Environments that are built of as a development parallel to Personal Learning Environments. Based on the results…

  1. Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure.

    PubMed

    Razak, Nasrul Anuar Abd; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq

    2014-08-01

    The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. The subject's dynamic pressure on the socket that's applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics.

  2. Sodium hyaluronate accelerates the healing process in tooth sockets of rats.

    PubMed

    Mendes, Renato M; Silva, Gerluza A B; Lima, Miguel F; Calliari, Marcelo V; Almeida, Alvair P; Alves, José B; Ferreira, Anderson J

    2008-12-01

    In this study we evaluated the effects of sodium hyaluronate (HY) in the healing process of tooth sockets of rats. Immediately after the extraction of the upper first molars of male Holtzman rats, right sockets were treated with 1% HY gel (approximately 0.1 ml), while left sockets were used as control (blood clot). The animals were sacrificed at 2, 7, and 21 days after tooth extraction and upper maxillaries processed for histological and morphometric analysis of the apical and medium thirds of the sockets. Carbopol, an inert gel, was used to evaluate the mechanical effect of gel injection into sockets. Expression of bone morphogenetic protein-2 (BMP-2) and osteopontin (OPN) was determined by immunohistochemistry at 1, 2, 3, 4, 5, and 7 days after tooth extraction. Histological analysis showed that HY treatment induced earlier trabecular bone deposition resulting in a bone matrix more organized at 7 and 21 days after tooth extraction. Also, HY elicited significant increase in the amount of bone trabeculaes at 7 and 21 days after tooth extraction (percentage of trabecular bone area at 7 days: 13.21+/-4.66% vs. 2.58+/-1.36% in the apical third of control sockets) and in the vessels counting at 7 days. Conversely, the number of cell nuclei was decreased in HY-treated sockets. Additionally, expression of BMP-2 and OPN was enhanced in HY-treated sockets compared with control sockets. These findings suggest that HY accelerates the healing process in tooth sockets of rats stimulating the expression of osteogenic proteins.

  3. X-38 on B-52 Wing Pylon - View from Observation Window

    NASA Image and Video Library

    1997-11-19

    A unique, close-up view of the X-38 under the wing of NASA's B-52 mothership prior to launch of the lifting-body research vehicle. The photo was taken from the observation window of the B-52 bomber as it banked in flight.

  4. Discharge and infection in retinoblastoma post-enucleation sockets

    PubMed Central

    Mourits, Daphne L; Hartong, Dyonne T; Budding, Andries E; Bosscha, Machteld I; Tan, H Stevie; Moll, Annette C

    2017-01-01

    Purpose To investigate the causes and treatment options for socket discharge and infection in patients enucleated for retinoblastoma (Rb). Methods A questionnaire was filled out by (parents of) ocular prosthesis-wearing patients with a history of enucleation as treatment for Rb. We collected data on patients’ characteristics, cleaning habits of the prosthesis, frequency of socket irritation, discharge, and infection, and use of antibiotics. With ordinal logistic regression analysis, factors related to the outcome parameters (frequency of irritation, mucoid and purulent discharge) were identified. In a subset of young asymptomatic and symptomatic patients, a swab culture of the socket was performed to determine the presence of microorganisms. Results A total of 186 patients or their parents (mean age of the patients: 17.3 years, ranging from 0.8 to 88.3 years) filled out the questionnaire. Irritation, mucoid discharge, and purulent discharge were frequently (once a month or more often) experienced in 75 (39.5%), 127 (66.8%), and 15 (13.2%) sockets, respectively. Younger age was associated with a higher frequency of mucoid and purulent discharge. Radiation therapy, chemotherapy, gender, age at surgery, cleaning frequency, and nocturnal wear were not associated with the outcome parameters. In a subgroup of 26 patients, the sockets were swabbed and cultured. All symptomatic patients had a positive bacterial culture versus 15% (2/13) of the asymptomatic patients (P<0.001). Common cold was correlated with both symptoms and presence of bacteria. Haemophilus influenzae and Staphylococcus aureus were the species most frequently cultured. Conclusion Ocular prosthesis-wearing patients often experienced mucoid discharge, and less often irritation and socket infection. These complaints were found to decrease with increasing age, but did not seem to be influenced by cleaning or wearing habits. Symptomatic sockets, with and without discharge, were correlated with the presence

  5. Discharge and infection in retinoblastoma post-enucleation sockets.

    PubMed

    Mourits, Daphne L; Hartong, Dyonne T; Budding, Andries E; Bosscha, Machteld I; Tan, H Stevie; Moll, Annette C

    2017-01-01

    To investigate the causes and treatment options for socket discharge and infection in patients enucleated for retinoblastoma (Rb). A questionnaire was filled out by (parents of) ocular prosthesis-wearing patients with a history of enucleation as treatment for Rb. We collected data on patients' characteristics, cleaning habits of the prosthesis, frequency of socket irritation, discharge, and infection, and use of antibiotics. With ordinal logistic regression analysis, factors related to the outcome parameters (frequency of irritation, mucoid and purulent discharge) were identified. In a subset of young asymptomatic and symptomatic patients, a swab culture of the socket was performed to determine the presence of microorganisms. A total of 186 patients or their parents (mean age of the patients: 17.3 years, ranging from 0.8 to 88.3 years) filled out the questionnaire. Irritation, mucoid discharge, and purulent discharge were frequently (once a month or more often) experienced in 75 (39.5%), 127 (66.8%), and 15 (13.2%) sockets, respectively. Younger age was associated with a higher frequency of mucoid and purulent discharge. Radiation therapy, chemotherapy, gender, age at surgery, cleaning frequency, and nocturnal wear were not associated with the outcome parameters. In a subgroup of 26 patients, the sockets were swabbed and cultured. All symptomatic patients had a positive bacterial culture versus 15% (2/13) of the asymptomatic patients ( P <0.001). Common cold was correlated with both symptoms and presence of bacteria. Haemophilus influenzae and Staphylococcus aureus were the species most frequently cultured. Ocular prosthesis-wearing patients often experienced mucoid discharge, and less often irritation and socket infection. These complaints were found to decrease with increasing age, but did not seem to be influenced by cleaning or wearing habits. Symptomatic sockets, with and without discharge, were correlated with the presence of pathogenic bacteria for which

  6. The effect of cancer therapies on pediatric anophthalmic sockets.

    PubMed

    Shildkrot, Yevgeniy; Kirzhner, Maria; Haik, Barrett G; Qaddoumi, Ibrahim; Rodriguez-Galindo, Carlos; Wilson, Matthew W

    2011-12-01

    To determine the impact of chemotherapy or external beam radiotherapy (EBRT) on pediatric anophthalmic sockets. A retrospective, nonrandomized, interventional cohort study. A total of 135 sockets of 133 children undergoing enucleation from late 1999 to early 2009 at the St. Jude Children's Research Hospital were included. A retrospective chart review of outcomes after enucleation in patients treated with systemic chemotherapy or orbital EBRT either before or after removal of the eye compared with patients who received no other treatment. Incidence of implant exposure, migration, extrusion, socket contracture, and pyogenic granuloma formation. Retinoblastoma was the primary diagnosis in 128 eyes (95%). Median follow-up was 3.6 years (range, 0.1-9.3 years). Event-free course was observed in 94 sockets (69.6%). Complications included implant exposure (n = 28, 20.7%), socket contracture (n = 16, 11.9%), pyogenic granuloma (n = 9, 6.7%), implant extrusion (n = 3, 2.2%), and migration (n = 2, 1.5%). Exposure resolved in 21 sockets (77.8%) and improved in 2 sockets (11.1%); 1 patient with exposure died. Use of prior, adjuvant, or subsequent chemotherapy increased the long-term risk of exposure (odds ratio [OR] = 3.7; 95% confidence interval [CI], 1.4-9.4), and contracture (OR could not be calculated, P<0.0001). External beam radiotherapy greatly increased the risk of contracture (OR 24.0; 95% CI, 6.9-82.8) and exposure (OR 2.89; 95% CI, 1.1-7.9). In this unique pediatric population with cancer, chemotherapy and EBRT had an additive effect, significantly increasing the incidence of exposure and socket contracture. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure

    PubMed Central

    2014-01-01

    Background The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee’s satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. Methods The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. Results The subject’s dynamic pressure on the socket that’s applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. Conclusion The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics. PMID:25085005

  8. Effectiveness of intra-alveolar chlorhexidine gel in reducing dry socket following surgical extraction of lower third molars. A pilot study.

    PubMed

    Requena-Calla, Silvana; Funes-Rumiche, Italo

    2016-04-01

    Dry socket is one of the most studied complications in dentistry and several studies have sought an effective and safe method for its prevention and treatment. The aim of this study was to evaluate the effectiveness of intra-alveolar gel chlorhexidine in preventing dry socket after the surgical removal of third molars. The sample involved the treatment of 40 patients who required extraction of third molars impacted, which were randomly assigned to research groups: experimental group (chlorhexidine gel 0.12%) and control group (placebo gel). Performed the extraction was administered 1 mL of chlorhexidine gel or 1 mL of placebo gel within the socket. The removal of suture was on the fifth postoperative day in which the presence or absence of dry socket was evaluated. No relationship between the appearance of dry socket after application of chlorhexidine gel or placebo gel (X2 test, p = 0.311) was found. However, significant differences (U Mann-Whitney test, p = 0.036) in the pain presented on the fifth postoperative day were evident (VAS). The administration of intra-alveolar chlorhexidine gel 0.12% could generate a better response to postoperative pain after the removal of third molars. Third molar surgery, dry socket, chorhexidine gel.

  9. Prosthetic Correction of Postenucleation Socket Syndrome: A Case Report.

    PubMed

    Kamble, Vikas B

    2014-12-01

    Postenucleation socket syndrome is a frequent late complication of enucleation of eye globe. Several pathophysiological mechanisms have been proposed to account for the symptoms of postenucleation socket syndrome, which include lost orbital volume, superior sulcus deformity, upper eyelid ptosis, lower eyelid laxity, and backward tilt of the prosthesis. The goal of postenucleation socket syndrome treatment is to achieve the best possible functional and esthetic result. The treatment can be either conservative or surgical. For the patient interested in a non-surgical correction, the conservative treatment is simple and non invasive and can be done with prosthesis modification for good positioning, comfort, and mobility. This paper describes prosthetic correction of a patient with postenucleation socket syndrome by modified ocular prosthesis.

  10. Novel high-pressure windows made of glass-like carbon for x-ray analysis.

    PubMed

    Testemale, Denis; Prat, Alain; Lahera, Eric; Hazemann, Jean-Louis

    2016-07-01

    Original high-pressure glass-like carbon windows developed for x-ray spectroscopy applications are presented. The scientific and technological background of this new technical development is exposed, in particular the limitations of our existing beryllium windows in the context of x-ray absorption spectroscopy (XAS) measurements of solutions with very low solute concentrations at hydrothermal conditions (0.1-200 MPa, 30-600 °C). The benefits of glass-like carbon are exposed, notably its non-crystalline character, the absence of impurities which has been verified by micro-fluorescence laboratory measurements, and its non-toxicity which makes its machining safer. Finite elements mechanical calculations and experimental pressure tests were conducted to determine the pressure limits of windows with two different geometries: cylindrical (thickness 0.5 mm) and inversed-dome shape (thickness 0.5 mm at the tip of the dome). The former break at 150 MPa and the latter show no sign of rupture at 400 MPa. Recent XAS measurements conducted with the new dome shaped windows are presented to show the advantages of the design that allow for the detection of very low concentrations in the transmission mode (down to 30 ppm) and the acquisition of fluorescence XAS spectra in diluted solutions at high pressure. Eventually the perspectives of this original development are discussed.

  11. Interventions for the prevention of dry socket: an evidence-based update.

    PubMed

    Sharif, M O; Dawoud, B E S; Tsichlaki, A; Yates, J M

    2014-07-11

    This paper reviews the latest evidence for local and systemic interventions for the prevention of alveolar osteitis (dry socket). Dry socket is a painful and common post-operative complication following exodontia. Any interventions for the prevention of dry socket could reduce both its incidence and help avoid this painful complication. Prophylactic measures proposed in the literature are discussed. Furthermore, this article discusses both the clinical and histological stages of a normal healing socket.

  12. Histologic effects of intentional-socket-assisted orthodontic movement in rabbits.

    PubMed

    Yu, Ji-Yeon; Lee, Won; Park, Jae Hyun; Bayome, Mohamed; Kim, Yong; Kook, Yoon-Ah

    2012-08-01

    This study aimed to evaluate the effect of an intentionally created socket on bone remodeling with orthodontic tooth movement in rabbits. Eighteen male rabbits weighing 3.8 - 4.25 kg were used. An 8-mm deep and 2-mm wide socket was drilled in the bone 1 mm mesial to the right mandibular first premolar. The left first premolar was extracted to serve as an extraction socket. A traction force of 100 cN was applied to the right first premolar and left second premolar. Sections were obtained at the middle third of the moving tooth for both the drilled and extraction sockets and evaluated with hematoxylin and eosin staining and immunohistochemical analyses. The amount of tooth movement and tartrate-resistant acid phosphatase (TRAP)-positive cell count were compared between the 2 groups using the Mann-Whitney U test. At week 2, the distance of tooth movement was significantly higher in the intentional socket group (p < 0.05) than in the extraction socket group. The number of TRAP-positive cells decreased in week 2 but increased in week 3 (p < 0.05). However, there were no significant differences between the groups. Furthermore, results of transforming growth factor (TGF)-β staining revealed no significant differences. The intentional socket group showed greater distance of tooth movement than did the extraction socket group at week 2. Osteoclast counts and results of immunohistochemical analyses suggested elevated bone remodeling in both the groups. Thus, osteotomy may be an effective modality for enhancing tooth movement in orthodontic treatment.

  13. Component-Based Visualization System

    NASA Technical Reports Server (NTRS)

    Delgado, Francisco

    2005-01-01

    A software system has been developed that gives engineers and operations personnel with no "formal" programming expertise, but who are familiar with the Microsoft Windows operating system, the ability to create visualization displays to monitor the health and performance of aircraft/spacecraft. This software system is currently supporting the X38 V201 spacecraft component/system testing and is intended to give users the ability to create, test, deploy, and certify their subsystem displays in a fraction of the time that it would take to do so using previous software and programming methods. Within the visualization system there are three major components: the developer, the deployer, and the widget set. The developer is a blank canvas with widget menu items that give users the ability to easily create displays. The deployer is an application that allows for the deployment of the displays created using the developer application. The deployer has additional functionality that the developer does not have, such as printing of displays, screen captures to files, windowing of displays, and also serves as the interface into the documentation archive and help system. The third major component is the widget set. The widgets are the visual representation of the items that will make up the display (i.e., meters, dials, buttons, numerical indicators, string indicators, and the like). This software was developed using Visual C++ and uses COTS (commercial off-the-shelf) software where possible.

  14. Characterization of interfacial socket pressure in transhumeral prostheses: A case series.

    PubMed

    Schofield, Jonathon S; Schoepp, Katherine R; Williams, Heather E; Carey, Jason P; Marasco, Paul D; Hebert, Jacqueline S

    2017-01-01

    One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user's morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools.

  15. Improving socket design to prevent difficult removal of locking screws.

    PubMed

    Lin, Chen-Huei; Chao, Ching-Kong; Tang, Yi-Hsuan; Lin, Jinn

    2018-03-01

    Reports of driver slippage leading to difficult locking screw removals have increased since the adoption of titanium for screw fabrication; the use of titanium is known to cause cross-threading and cold welding. Such problems occur most frequently in screws with hex sockets, and may cause serious surgical complications. This study aimed to improve screw socket design to prevent slippage and difficult screw removal. Three types of small sockets (hex, Torx, and cruciate) and six types of large sockets (hex, Torx, Octatorx, Torx+ I, Torx+ II, and Torx+ III) with screw head diameters of 5.5 mm were manufactured from titanium, and corresponding screwdrivers were manufactured from stainless steel. The screw heads and drivers were mounted on a material testing machine, and torsional tests were conducted to simulate screw usage in clinical settings at two insertion depths: 1 and 2 mm. Ten specimens were tested from each design, and the maximum torque and failure patterns were recorded and compared. For small sockets in 2 mm conditions, the hex with the largest driver core had the highest torque, followed by Torx and cruciate. In these tests, the drivers were twisted off in all specimens. However, under the 1 mm condition, the hex slipped and the torque decreased markedly. Overall, torque was higher for large sockets than for small sockets. The Octatorx, with a large core and simultaneous deformation of the driver and socket lobes, had the highest torque at almost twice that of the small hex. The hex had the lowest torque, a result of slippage in both the 1 and 2 mm conditions. Torx plus designs, with more designed degrees of freedom, were able to maintain a higher driving angle and larger core for higher torque. The hex design showed slipping tendencies with a marked decrease in torque, especially under conditions with inadequate driver engagement. Large sockets allowed for substantial increases in torque. The Torx, Octatorx, and Torx plus designs displayed

  16. Conjunctival Blue Naevus in an Anophthalmic Socket.

    PubMed

    Quhill, Hibba; Rundle, Paul A; Mudhar, Hardeep Singh

    2017-09-01

    To describe an unusual brown pigmented lesion of the conjunctiva in an anophthalmic socket in a 16-year-old male. A 16-year-old male patient presented with socket irritation whilst wearing an artificial eye due to meibomian gland dysfunction. An area of flat, subepithelial, dark brown pigmentation with irregular and indistinct borders on the bulbar conjunctiva of the anophthalmic socket was seen. The patient believed it had been present for at least 2 years. His past ocular history was of childhood trauma to the right eye at the age of 9 years, and he underwent primary enucleation and hydroxyapatite orbital implant insertion at that time. Unfortunately, the implant extruded and was removed a year later. An incisional biopsy of the pigmented lesion showed a conjunctival, subepithelial bland spindle cell melanocytic lesion, with uniform-sized and -shaped melanosomes. Immunohistochemistry showed the cells to express Melan A and HMB45 and they were negative for CD68 and pan-cytokeratins. The features were of a common blue naevus. This is the first documentation of a post-enucleation conjunctival naevus in an anophthalmic socket. We propose a pathogenesis and suggest surveillance as there is a risk of transformation to melanoma.

  17. Novel high-pressure windows made of glass-like carbon for x-ray analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Testemale, Denis; Prat, Alain; Lahera, Eric

    Original high-pressure glass-like carbon windows developed for x-ray spectroscopy applications are presented. The scientific and technological background of this new technical development is exposed, in particular the limitations of our existing beryllium windows in the context of x-ray absorption spectroscopy (XAS) measurements of solutions with very low solute concentrations at hydrothermal conditions (0.1-200 MPa, 30-600 °C). The benefits of glass-like carbon are exposed, notably its non-crystalline character, the absence of impurities which has been verified by micro-fluorescence laboratory measurements, and its non-toxicity which makes its machining safer. Finite elements mechanical calculations and experimental pressure tests were conducted to determine the pressuremore » limits of windows with two different geometries: cylindrical (thickness 0.5 mm) and inversed-dome shape (thickness 0.5 mm at the tip of the dome). The former break at 150 MPa and the latter show no sign of rupture at 400 MPa. Recent XAS measurements conducted with the new dome shaped windows are presented to show the advantages of the design that allow for the detection of very low concentrations in the transmission mode (down to 30 ppm) and the acquisition of fluorescence XAS spectra in diluted solutions at high pressure. Eventually the perspectives of this original development are discussed.« less

  18. Characterization of interfacial socket pressure in transhumeral prostheses: A case series

    PubMed Central

    Schoepp, Katherine R.; Williams, Heather E.; Carey, Jason P.; Marasco, Paul D.

    2017-01-01

    One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user’s morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools. PMID:28575012

  19. Three dimensional socket preservation: a technique for soft tissue augmentation along with socket grafting

    PubMed Central

    2012-01-01

    Background A cursory review of the current socket preservation literatures well depicts the necessity of further esthetic considerations through the corrective procedures of the alveolar ridge upon and post extraction. A new technique has been described here is a rotational pedicle combined epithelialized and connective tissue graft (RPC graft) adjunct with immediate guided tissue regeneration (GBR) procedure. Results We reviewed this technique through a case report and discuss it’s benefit in compare to other socket preservation procedures. Conclusion The main advantages of RPC graft would be summarized as follows: stable primary closure during bone remodeling, saving or crating sufficient vestibular depth, making adequate keratinized gingiva on the buccal surface, and being esthetically pleasant. PMID:22540920

  20. The Effect of Prosthetic Socket Interface Design on Socket Comfort, Residual Limb Health, and Function for the Transfemoral Amputee

    DTIC Science & Technology

    2016-10-01

    laminated rigid frame to reduce thermal layers, increase flexibility and comfort while retaining ischial containment. In contrast, a Sub-I design has...design is comprised of a flexible interface and minimal laminated rigid frame to reduce thermal layers, increase flexibility and comfort while...AWARD NUMBER: W81XWH-15-1-0410 TITLE: The Effect of Prosthetic Socket Interface Design on Socket Comfort , Residual Limb Health, and Function

  1. The modular socket system in a rural setting in Indonesia.

    PubMed

    Giesberts, Bob; Ennion, Liezel; Hjelmstrom, Olle; Karma, Agusni; Lechler, Knut; Hekman, Edsko; Bergsma, Arjen

    2018-06-01

    Prosthetic services are inaccessible to people living in rural areas. Systems like the modular socket system have the potential to be fabricated outside of the prosthetic workshop. This study aimed to evaluate the patient's performance and satisfaction with the use of the modular socket system, and the technical feasibility of its implementation in a rural setting. A quantitative longitudinal descriptive study design was followed. A total of 15 persons with a lower limb amputation were fitted with the modular socket system and followed over 4-6 months. Performance was measured using a 2-min walk test, 10-m walk test and mobility and function questionnaire. Satisfaction was measured by the Socket Fit Comfort Score, Prosthesis Evaluation Questionnaire and EuroQoL 5 Dimensions 5 Levels. Notes on technical feasibility were taken at the moment of fitting ( t 0 ), at 1-3 months post fitting ( t 1 ) and at the end evaluation at 4-6 months post fitting ( t 2 ). Performance did not change between t 0 and t 2 . The comfort of the socket fit reduced between t 0 and t 2 . Satisfaction with prosthesis and general health status stayed constant over time. The average fitting-time for the modular socket system was 6.4 h. The modular socket system can be considered a useful alternative for use in rural settings. Clinical relevance The use of the modular socket system is feasible and can improve accessibility to prosthetic technology in rural areas. Experienced prosthetic users were satisfied with the performance and the device. The shorter manufacturing time and use of only hand-held tools makes it an ideal alternative for use in remote and rural settings.

  2. Timeframe of socket cortication after tooth extraction: A retrospective radiographic study.

    PubMed

    Bertl, Kristina; Kukla, Edmund Benjamin; Albugami, Rajaa; Beck, Florian; Gahleitner, André; Stavropoulos, Andreas

    2018-01-01

    To assess the timeframe between tooth extraction and radiographically detectable socket cortication in humans. Two hundred and fifty patients with a CT scan ≤36 months after tooth extraction were included. First, three orthoradial multiplanar reconstruction slices, representing the major part of the extraction socket, were scored regarding the degree of bone healing as (i) healed, that is, complete/continuous cortication of the socket entrance, or (ii) non-healed. Thereafter, based on the results of all three slices, the stage of cortication of the extraction socket, as one unit, was classified as (i) non-corticated, that is, all three slices judged as non-healed, (ii) partially corticated, that is, 1 or 2 slices judged as non-healed, or (iii) completely corticated, that is, all three slices judged as healed. The possible effect of several independent parameters, that is, age, gender, timeframe between tooth extraction and CT scan, tooth type, extent of radiographic bone loss of the extracted tooth, tooth-gap type, smoking status, presence of any systemic disease, and medication intake, on cortication status was statistically evaluated. Three to 6 months after tooth extraction, 27% of the sockets were judged as non-corticated and 53% were judged as partially corticated. After 9-12 months, >80% of the sockets were corticated, while some incompletely corticated sockets were detected up to 15 months after extraction. Each additional month after tooth extraction contributed significantly to a higher likelihood of a more advanced stage of cortication, while radiographic bone loss ≥75% significantly prolonged cortication time; no other independent variable had a significant effect. The results indicate a considerably long timeframe until complete cortication of an extraction socket, that is, 3-6 months after tooth extraction 3 of 4 sockets were still not completely corticated, and only after 9-12 months, complete cortication was observed in about 80% of the

  3. Q14 - Standards Development Plan, Ada Interfaces to X Window System, Analysis and Recommendations

    DTIC Science & Technology

    1989-03-20

    portability and reusability. -, . /- , ... ’ 4t. I-,: 2 Introduction Two major thrusts of the STARS program, and industry as a whole, are application...and IEEE, and in industry consortiums to show the directions X is taking and the opportunities for Ada to utilize this work. X is not the only window...and actually prohibit portability, but to avoid this the X developers formed the X Consortium, consisting of industry and academic members, who define

  4. Autotransplantation of third molars with completely formed roots into surgically created sockets and fresh extraction sockets: a 10-year comparative study.

    PubMed

    Yu, H J; Jia, P; Lv, Z; Qiu, L X

    2017-04-01

    The aim of this study was to analyze and compare the long-term clinical outcomes of mature third molar autotransplantation in surgically created sockets and fresh extraction sockets with regard to survival and functional success rates. A total of 65 third molars with completely formed roots were autotransplanted in 60 patients (average age 33.1 years). Thirty-six of the teeth were autotransplanted into surgically created sockets with or without guided bone regeneration (GBR; delayed autotransplantation), while 29 were autotransplanted into fresh extraction sockets (immediate autotransplantation; control group). All patients underwent annual clinical and radiographic examinations (average follow-up 9.9 years, range 7-13 years). The survival rates for the control, GBR, and no GBR groups were 93.1%, 95.2%, and 80.0%, respectively, with no significant differences among the groups. There were no statistically significant differences among the groups with regard to the frequency of inflammatory root resorption or root ankylosis. Age did not influence the clinical outcomes. These results suggest that the autotransplantation of third molars with completely formed roots is effective in both surgically created and fresh extraction sockets and provides a high long-term success rate if cases are selected and treated appropriately. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Ball and Socket Ankle: Mechanism and Computational Evidence of Concept.

    PubMed

    Jastifer, James R; Gustafson, Peter A; Labomascus, Aaron; Snoap, Tyler

    The ball and socket ankle joint is a morphologically abnormal joint characterized by rounding of the articular surface of the talus. Other than anecdotal observation, little evidence has been presented to describe the development of this deformity. The purpose of the present study was to review ankle and subtalar joint mechanics and to kinematically examine the functional combination of these joints as a mechanism of the ball and socket ankle deformity. We reviewed functional representations of the ankle joint, subtalar joint, and ball and socket ankle deformity. A computational study of joint kinematics was then performed using a 3-dimensional model derived from a computed tomography scan of a ball and socket deformity. The joint kinematics were captured by creating a "virtual map" of the combined kinematics of the ankle and subtalar joints in the respective models. The ball and socket ankle deformity produces functionally similar kinematics to a combination of the ankle and subtalar joints. The findings of the present study support the notion that a possible cause of the ball and socket deformity is bony adaptation that compensates for a functional deficit of the ankle and subtalar joints. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Platelet rich fibrin in the management of established dry socket.

    PubMed

    Chakravarthi, Srinivas

    2017-06-01

    Dry socket may occur secondary to the removal of any tooth. However, most dry socket cases develop in the third molar region. Dry socket is multifactorial in nature and has been treated using various modalities with varying success rates. This study assessed the efficacy of platelet rich fibrin (PRF) in established dry socket. Ten patients of either sex aged from 41 to 64 years with established dry socket according to established criteria were treated using PRF. Evaluation was performed by observing the reduction of pain using visual analogue scale, analgesic tablet use over the follow-up period, and healing parameters. Pain was reduced on the first day in all patients with decreased analgesic use. Pain was drastically reduced during follow-up on the first, second, third, and seventh days with a fall in pain score of 0 to 1 after the first day alone. The pain scores of all patients decreased to 1 by the first day except in one patient, and the scores decreased to 0 in all patients after 48 hours. Total analgesic intake ranged from 2 to 6 tablets (aceclofenac 100 mg per tablet) over the follow-up period of 7 days. Healing was satisfactory in all patients by the end of the seventh day. PRF showed early pain reduction in established dry socket with minimal analgesic intake. No patients had allergic reactions to PRF as it is derived from the patient's own blood. PRF showed good wound healing. Our study suggests that PRF should be considered as a treatment modality for established dry socket.

  7. Quantification of rectifications for the Northwestern University Flexible Sub-Ischial Vacuum Socket.

    PubMed

    Fatone, Stefania; Johnson, William Brett; Tran, Lilly; Tucker, Kerice; Mowrer, Christofer; Caldwell, Ryan

    2017-06-01

    The fit and function of a prosthetic socket depend on the prosthetist's ability to design the socket's shape to distribute load comfortably over the residual limb. We recently developed a sub-ischial socket for persons with transfemoral amputation: the Northwestern University Flexible Sub-Ischial Vacuum Socket. This study aimed to quantify the rectifications required to fit the Northwestern University Flexible Sub-Ischial Vacuum Socket to teach the technique to prosthetists as well as provide a computer-aided design-computer-aided manufacturing option. Development project. A program was used to align scans of unrectified and rectified negative molds and calculate shape change as a result of rectification. Averaged rectifications were used to create a socket template, which was shared with a central fabrication facility engaged in provision of Northwestern University Flexible Sub-Ischial Vacuum Sockets to early clinical adopters. Feedback regarding quality of fitting was obtained. Rectification maps created from 30 cast pairs of successfully fit Northwestern University Flexible Sub-Ischial Vacuum Sockets confirmed that material was primarily removed from the positive mold in the proximal-lateral and posterior regions. The template was used to fabricate check sockets for 15 persons with transfemoral amputation. Feedback suggested that the template provided a reasonable initial fit with only minor adjustments. Rectification maps and template were used to facilitate teaching and central fabrication of the Northwestern University Flexible Sub-Ischial Vacuum Socket. Minor issues with quality of initial fit achieved with the template may be due to inability to adjust the template to patient characteristics (e.g. tissue type, limb shape) and/or the degree to which it represented a fully mature version of the technique. Clinical relevance Rectification maps help communicate an important step in the fabrication of the Northwestern University Flexible Sub-Ischial Vacuum

  8. Immediate implant placement into fresh extraction sockets versus delayed implants into healed sockets: A systematic review and meta-analysis.

    PubMed

    Mello, C C; Lemos, C A A; Verri, F R; Dos Santos, D M; Goiato, M C; Pellizzer, E P

    2017-09-01

    The aim of this systematic review and meta-analysis was to compare the survival rate of the implants and the peri-implant tissue changes associated with implants inserted in fresh extraction sockets and those inserted in healed sockets. This review has been registered at PROSPERO under the number CRD42016043309. A systematic search was conducted by two reviewers independently in the databases PubMed/MEDLINE, Embase, and the Cochrane Library using different search terms; articles published until November 2016 were searched for. The searches identified 30 eligible studies. A total of 3,049 implants were installed in a total of 1,435 patients with a mean age of 46.68 years and a minimum of 6 months of follow-up. The survival rate of delayed implants (98.38%) was significantly greater than immediate implants (95.21%) (p=.001). For the marginal bone loss (p=.32), implant stability quotients values (p=.44), and pocket probing depth (p=.94) there was no significant difference between the analysed groups. The immediate implants placed in fresh sockets should be performed with caution because of the significantly lower survival rates than delayed implants inserted in healed sockets. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Healing of ungrafted and grafted extraction sockets after 12 weeks: a prospective clinical study.

    PubMed

    Heberer, Susanne; Al-Chawaf, Bassem; Jablonski, Carlo; Nelson, John J; Lage, Hermann; Nelson, Katje

    2011-01-01

    In this prospective study, bone formation in human extraction sockets augmented with Bio-Oss Collagen after a 12-week healing period was quantified and compared to bone formation in unaugmented extraction sockets. Selected patients with four-walled extraction sockets were included in this prospective study. After extraction, the sockets were randomly augmented using Bio-Oss Collagen or left to heal unfilled without raising a mucoperiosteal flap. At the time of implant placement, histologic specimens were obtained from the socket and analyzed. Statistical analysis was performed using the Wilcoxon signed-rank test. Twenty-five patients with a total of 39 sockets (20 augmented, 19 unaugmented) were included in the study and the histologic specimens analyzed. All specimens were free of inflammatory cells. The mean overall new bone formation in the augmented sites was 25% (range, 8%-41%) and in the unaugmented sockets it was 44% (range, 3%-79%). There was a significant difference in the rate of new bone formation between the grafted and ungrafted sockets and a significant difference in the bone formation rate in the apical compared to the coronal regions of all sockets, independent of the healing mode. This descriptive study demonstrated that bone formation in Bio-Oss Collagen-grafted human extraction sockets was lower than bone formation in ungrafted sockets. Bone formation occurred in all specimens with varying degrees of maturation independent of the grafting material and was initiated from the apical region.

  10. Coronal plane socket stability during gait in persons with transfemoral amputation: Pilot study.

    PubMed

    Fatone, Stefania; Dillon, Michael; Stine, Rebecca; Tillges, Robert

    2014-01-01

    Little research describes which transfemoral socket design features are important for coronal plane stability, socket comfort, and gait. Our study objectives were to (1) relate socket comfort during gait to a rank order of changes in ischial containment (IC) and tissue loading and (2) compare socket comfort during gait when tissue loading and IC were systematically manipulated. Six randomly assigned socket conditions (IC and tissue compression) were assessed: (1) IC and high, (2) IC and medium, (3) IC and low, (4) no IC and high, (5) no IC and medium, and (6) no IC and low. For the six subjects in this study, there was a strong, negative relationship between comfort and changes in IC and tissue loading (rho = -0.89). With the ischium contained, tissue loading did not influence socket comfort (p = 0.47). With no IC, the socket was equally comfortable with high tissue loading (p = 0.36) but the medium (p = 0.04) and low (p = 0.02) tissue loading conditions decreased comfort significantly. Coronal plane hip moments, lateral trunk lean, step width, and walking speed were invariant to changes in IC and/or tissue loading. Our results suggest that in an IC socket, medial tissue loading mattered little in terms of comfort. Sockets without IC required high tissue loading to be as comfortable as those with IC, while suboptimal tissue loading compromised comfort.

  11. Platelet rich fibrin in the management of established dry socket

    PubMed Central

    2017-01-01

    Objectives Dry socket may occur secondary to the removal of any tooth. However, most dry socket cases develop in the third molar region. Dry socket is multifactorial in nature and has been treated using various modalities with varying success rates. This study assessed the efficacy of platelet rich fibrin (PRF) in established dry socket. Materials and Methods Ten patients of either sex aged from 41 to 64 years with established dry socket according to established criteria were treated using PRF. Evaluation was performed by observing the reduction of pain using visual analogue scale, analgesic tablet use over the follow-up period, and healing parameters. Results Pain was reduced on the first day in all patients with decreased analgesic use. Pain was drastically reduced during follow-up on the first, second, third, and seventh days with a fall in pain score of 0 to 1 after the first day alone. The pain scores of all patients decreased to 1 by the first day except in one patient, and the scores decreased to 0 in all patients after 48 hours. Total analgesic intake ranged from 2 to 6 tablets (aceclofenac 100 mg per tablet) over the follow-up period of 7 days. Healing was satisfactory in all patients by the end of the seventh day. Conclusion PRF showed early pain reduction in established dry socket with minimal analgesic intake. No patients had allergic reactions to PRF as it is derived from the patient's own blood. PRF showed good wound healing. Our study suggests that PRF should be considered as a treatment modality for established dry socket. PMID:28770156

  12. Residual-stress measurement in socket welded joints by neutron diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hayashi, M.; Ishiwata, M.; Minakawa, N.

    1994-12-31

    Neutron diffraction measurements of lattice strains provide spatial maps of residual stress near welds in ferritic steel socket joints. The highest tensile stresses in the welds are found in axial, radial and hoop direction at the weld root. However, the highest tensile stress in the axial direction is about 110MPa. Balancing compressive stresses are found near the surface of the socket weld fusion zone. Heat treatment at 600 C for 2 hours is sufficient to relieve residual stress in socket welds.

  13. Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation: Part 2 Description and Preliminary evaluation.

    PubMed

    Fatone, Stefania; Caldwell, Ryan

    2017-06-01

    Current transfemoral prosthetic sockets are problematic as they restrict function, lack comfort, and cause residual limb problems. Development of a subischial socket with lower proximal trim lines is an appealing way to address this problem and may contribute to improving quality of life of persons with transfemoral amputation. The purpose of this study was to illustrate the use of a new subischial socket in two subjects. Case series. Two unilateral transfemoral prosthesis users participated in preliminary socket evaluations comparing functional performance of the new subischial socket to ischial containment sockets. Testing included gait analysis, socket comfort score, and performance-based clinical outcome measures (Rapid-Sit-To-Stand, Four-Square-Step-Test, and Agility T-Test). For both subjects, comfort was better in the subischial socket, while gait and clinical outcomes were generally comparable between sockets. While these evaluations are promising regarding the ability to function in this new socket design, more definitive evaluation is needed. Clinical relevance Using gait analysis, socket comfort score and performance-based outcome measures, use of the Northwestern University Flexible Subischial Vaccum Socket was evaluated in two transfemoral prosthesis users. Socket comfort improved for both subjects with comparable function compared to ischial containment sockets.

  14. The possible nature of socket stars in H II regions

    NASA Technical Reports Server (NTRS)

    Castelaz, Michael W.

    1990-01-01

    Close inspection of faint stars (V of about 14 mag) in H II regions show that they appear to be surrounded by circumstellar envelopes of about 10 arcsecs in diameter (as reported by Feibelman in 1989). The present premise is that the sockets are envelopes of obscuring dust which should emit a measurable amount of infrared radiation based on a simple thermal equilibrium model. A search of literature shows that, of 36 socket stars listed by Feibelman, 17 have been measured in the infrared. Of the 17, 14 show excess IR emission. This is very strong evidence that the socket stars are really stars with circumstellar envelopes. Socket stars may be a new type of astronomical object or well-known astronomical objects in environments or evolutionary states not previously seen.

  15. X-window-based 2K display workstation

    NASA Astrophysics Data System (ADS)

    Weinberg, Wolfram S.; Hayrapetian, Alek S.; Cho, Paul S.; Valentino, Daniel J.; Taira, Ricky K.; Huang, H. K.

    1991-07-01

    A high-definition, high-performance display station for reading and review of digital radiological images is introduced. The station is based on a Sun SPARC Station 4 and employs X window system for display and manipulation of images. A mouse-operated graphic user interface is implemented utilizing Motif-style tools. The system supports up to four MegaScan gray-scale 2560 X 2048 monitors. A special configuration of frame and video buffer yields a data transfer of 50 M pixels/s. A magnetic disk array supplies a storage capacity of 2 GB with a data transfer rate of 4-6 MB/s. The system has access to the central archive through an ultrahigh-speed fiber-optic network and patient studies are automatically transferred to the local disk. The available image processing functions include change of lookup table, zoom and pan, and cine. Future enhancements will provide for manual contour tracing, length, area, and density measurements, text and graphic overlay, as well as composition of selected images. Additional preprocessing procedures under development will optimize the initial lookup table and adjust the images to a standard orientation.

  16. OntoMaton: a bioportal powered ontology widget for Google Spreadsheets.

    PubMed

    Maguire, Eamonn; González-Beltrán, Alejandra; Whetzel, Patricia L; Sansone, Susanna-Assunta; Rocca-Serra, Philippe

    2013-02-15

    Data collection in spreadsheets is ubiquitous, but current solutions lack support for collaborative semantic annotation that would promote shared and interdisciplinary annotation practices, supporting geographically distributed players. OntoMaton is an open source solution that brings ontology lookup and tagging capabilities into a cloud-based collaborative editing environment, harnessing Google Spreadsheets and the NCBO Web services. It is a general purpose, format-agnostic tool that may serve as a component of the ISA software suite. OntoMaton can also be used to assist the ontology development process. OntoMaton is freely available from Google widgets under the CPAL open source license; documentation and examples at: https://github.com/ISA-tools/OntoMaton.

  17. Clinical outcome and complications of thoracic and pelvic limb stump and socket prostheses.

    PubMed

    Phillips, Andrew; Kulendra, Elvin; Bishop, Edith; Monk, Michelle; Parsons, Kevin; House, Arthur

    2017-07-20

    To describe the use, quality of life, compliance, complications, and outcome of animals fitted with stump socket prostheses. Medical records of dogs fitted with a stump socket prosthesis were reviewed. Functional outcome, quality of life and complications were retrospectively assessed from an owner questionnaire. Thirteen stump socket prostheses (12 dogs) were fitted for a variety of reasons including trauma, congenital abnormalities, and neoplasia. Eight dogs had a good outcome overall and four a poor outcome. Quality of life (QOL) remained good or excellent in 10/12 dogs. Nine complications were seen in 7/12 dogs, most were manageable; surgical wound complications (n = 2) and pressures sores (n = 4) were the most frequently encountered. One dog suffered multiple complications. Thoracic and pelvic limb stump socket prostheses had a similar complication rate, however all animals with a poor outcome had a thoracic limb stump socket prosthesis; two were small breed dogs (under 10 kg) and two had bilateral thoracic limb abnormalities. Stump socket prostheses are feasible and versatile in animals. In correctly selected cases, good to excellent outcomes are possible. However, complications are frequent but often manageable. Further investigations are required into the risk factors for poor outcomes and prospective studies are required to assess changes in biomechanics, function, and QOL before and after fitting of a stump socket prosthesis. Until further evidence is available, careful consideration should be given before fitting bilateral thoracic limb stump socket prostheses or thoracic limb stump socket prostheses to small breed dogs.

  18. Ball-and-Socket Joint Can Be Disassembled

    NASA Technical Reports Server (NTRS)

    Totah, R. S.

    1982-01-01

    Ball-and-socket joint originally developed for construction of large platforms in zero g could be used in such Earth-based temporary structures as scaffolding, camping equipment, tent posts, trade shows and displays. New joint consists of a socket mounted on central hub or union and ball-ended bolt or fitting mounted at end of a column or any structural member. Unit is self-contained, requires no loose hardware and is engaged or disengaged without tools manually, or remotely by a manipulator.

  19. Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation-Part 1: Description of technique.

    PubMed

    Fatone, Stefania; Caldwell, Ryan

    2017-06-01

    Current transfemoral prosthetic sockets restrict function, lack comfort, and cause residual limb problems. Lower proximal trim lines are an appealing way to address this problem. Development of a more comfortable and possibly functional subischial socket may contribute to improving quality of life of persons with transfemoral amputation. The purpose of this study was to (1) describe the design and fabrication of a new subischial socket and (2) describe efforts to teach this technique. Development project. Socket development involved defining the following: subject and liner selection, residual limb evaluation, casting, positive mold rectification, check socket fitting, definitive socket fabrication, and troubleshooting of socket fit. Three hands-on workshops to teach the socket were piloted and attended by 30 certified prosthetists and their patient models. Patient models responded positively to the comfort, range of motion, and stability of the new socket while prosthetists described the technique as "straight forward, reproducible." To our knowledge, this is the first attempt to create a teachable subischial socket, and while it appears promising, more definitive evaluation is needed. Clinical relevance We developed the Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket as a more comfortable alternative to current transfemoral sockets and demonstrated that it could be taught successfully to prosthetists.

  20. Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation: Part 2 Description and Preliminary evaluation

    PubMed Central

    Fatone, Stefania; Caldwell, Ryan

    2017-01-01

    Background: Current transfemoral prosthetic sockets are problematic as they restrict function, lack comfort, and cause residual limb problems. Development of a subischial socket with lower proximal trim lines is an appealing way to address this problem and may contribute to improving quality of life of persons with transfemoral amputation. Objectives: The purpose of this study was to illustrate the use of a new subischial socket in two subjects. Study design: Case series. Methods: Two unilateral transfemoral prosthesis users participated in preliminary socket evaluations comparing functional performance of the new subischial socket to ischial containment sockets. Testing included gait analysis, socket comfort score, and performance-based clinical outcome measures (Rapid-Sit-To-Stand, Four-Square-Step-Test, and Agility T-Test). Results: For both subjects, comfort was better in the subischial socket, while gait and clinical outcomes were generally comparable between sockets. Conclusion: While these evaluations are promising regarding the ability to function in this new socket design, more definitive evaluation is needed. Clinical relevance Using gait analysis, socket comfort score and performance-based outcome measures, use of the Northwestern University Flexible Subischial Vaccum Socket was evaluated in two transfemoral prosthesis users. Socket comfort improved for both subjects with comparable function compared to ischial containment sockets. PMID:28132589

  1. Biomechanical Analysis of a Filiform Mechanosensory Hair Socket of Crickets.

    PubMed

    Joshi, Kanishka; Mian, Ahsan; Miller, John

    2016-08-01

    Filiform mechanosensory hairs of crickets are of great interest to engineers because of the hairs' highly sensitive response to low-velocity air-currents. In this study, we analyze the biomechanical properties of filiform hairs of the cercal sensory system of a common house cricket. The cercal sensory system consists of two antennalike appendages called cerci that are situated at the rear of the cricket's abdomen. Each cercus is covered with 500-750 flow sensitive filiform mechanosensory hairs. Each hair is embedded in a complex viscoelastic socket that acts as a spring and dashpot system and guides the movement of the hair. When a hair deflects due to the drag force induced on its length by a moving air-current, the spiking activity of the neuron that innervates the hair changes and the combined spiking activity of all hairs is extracted by the cercal sensory system. Filiform hairs have been experimentally studied by researchers, though the basis for the hairs' biomechanical characteristics is not fully understood. The socket structure has not been analyzed experimentally or theoretically from a mechanical standpoint, and the characterization that exists is mathematical in nature and only provides a very rudimentary approximation of the socket's spring nature. This study aims to understand and physically characterize the socket's behavior and interaction with the filiform hair by examining hypotheses about the hair and socket biomechanics. A three-dimensional computer-aided design (CAD) model was first created using confocal microscopy images of the hair and socket structure of the cricket, and then finite-element analyses (FEAs) based on the physical conditions that the insect experiences were simulated. The results show that the socket can act like a spring; however, it has two-tier rotational spring constants during pre- and postcontacts of iris and hair bulge due to its constitutive nonstandard geometric shapes.

  2. Piezoelectric Bimorphs' Characteristics as In-Socket Sensors for Transfemoral Amputees

    PubMed Central

    El-Sayed, Amr M.; Hamzaid, Nur Azah; Osman, Noor Azuan Abu

    2014-01-01

    Alternative sensory systems for the development of prosthetic knees are being increasingly highlighted nowadays, due to the rapid advancements in the field of lower limb prosthetics. This study presents the use of piezoelectric bimorphs as in-socket sensors for transfemoral amputees. An Instron machine was used in the calibration procedure and the corresponding output data were further analyzed to determine the static and dynamic characteristics of the piezoelectric bimorph. The piezoelectric bimorph showed appropriate static operating range, repeatability, hysteresis, and frequency response for application in lower prosthesis, with a force range of 0–100 N. To further validate this finding, an experiment was conducted with a single transfemoral amputee subject to measure the stump/socket pressure using the piezoelectric bimorph embedded inside the socket. The results showed that a maximum interface pressure of about 27 kPa occurred at the anterior proximal site compared to the anterior distal and posterior sites, consistent with values published in other studies. This paper highlighted the capacity of piezoelectric bimorphs to perform as in-socket sensors for transfemoral amputees. However, further experiments are recommended to be conducted with different amputees with different socket types. PMID:25513823

  3. The influence of alendronate on the healing of extraction sockets of ovariectomized rats assessed by in vivo micro-computed tomography.

    PubMed

    Jee, Jeong-Hyun; Lee, Wan; Lee, Byung Do

    2010-08-01

    Many dental patients take bisphosphonates to reduce the risk of hip and vertebral fractures. In vivo micro-computed tomography (micro-CT) was used to examine the longitudinal inhibitory effect of alendronate on the healing of extraction sockets in ovariectomized rats. Twenty 5-week-old Sprague-Dawley rats were assigned randomly to 1 of 3 groups: sham-operated (n = 5), and 2 ovariectomized (OVX) groups: saline treated (0.1 mL/100 g/d, n = 7) and alendronate treated (1 mg/kg/d, n = 8). Before micro-CT scanning, the left maxillary first molars of the rats were extracted. In vivo micro-CT (spatial resolution 50 x 50 mum) of the jaw was performed at baseline and at 2-week intervals for 6 weeks. Alveolar-bone radiographic densities and dimensions were analyzed with repeated measures analysis of variance. The bony healing patterns of the extraction sockets were also evaluated in each group. The radiographic socket densities of the sham-treated and OVX-alendronate groups significantly increased during the first 4 weeks after extraction (P < .05). At 2 weeks, the radiographic densities of the sockets in the OVX-saline group increased, but the increase was significantly lower than for the other groups at 4 weeks (P < .05). Newly formed bone was identified in the extraction sockets in all groups 2 to 6 weeks after extraction. There was a significant loss of alveolar ridge height at the second week postextraction compared with baseline, and at the fourth week compared with the second week (P < .05) except in the alendronate group. Alendronate appears to promote the healing of extraction sockets in estrogen-deficient rats and helps resist the loss of alveolar bone adjacent to extraction sockets. Copyright 2010 Mosby, Inc. All rights reserved.

  4. Progress Toward Optimizing Prosthetic Socket Fit and Suspension Using Elevated Vacuum to Promote Residual Limb Health.

    PubMed

    Wernke, Matthew M; Schroeder, Ryan M; Haynes, Michael L; Nolt, Lonnie L; Albury, Alexander W; Colvin, James M

    2017-07-01

    Objective: Prosthetic sockets are custom made for each amputee, yet there are no quantitative tools to determine the appropriateness of socket fit. Ensuring a proper socket fit can have significant effects on the health of residual limb soft tissues and overall function and acceptance of the prosthetic limb. Previous work found that elevated vacuum pressure data can detect movement between the residual limb and the prosthetic socket; however, the correlation between the two was specific to each user. The overall objective of this work is to determine the relationship between elevated vacuum pressure deviations and prosthetic socket fit. Approach: A tension compression machine was used to apply repeated controlled forces onto a residual limb model with sockets of different internal volume. Results: The vacuum pressure-displacement relationship was dependent on socket fit. The vacuum pressure data were sensitive enough to detect differences of 1.5% global volume and can likely detect differences even smaller. Limb motion was reduced as surface area of contact between the limb model and socket was maximized. Innovation: The results suggest that elevated vacuum pressure data provide information to quantify socket fit. Conclusions: This study provides evidence that the use of elevated vacuum pressure data may provide a method for prosthetists to quantify and monitor socket fit. Future studies should investigate the relationship between socket fit, limb motion, and limb health to define optimal socket fit parameters.

  5. Change in residual limb size over time in the NU-FlexSIV socket: A case study.

    PubMed

    Fatone, Stefania; Yohay, Jessica; Caldwell, Ryan

    2018-05-01

    This case study represented a unique opportunity wherein a long-time user of sub-ischial sockets had kept nearly every socket he wore for a decade. This individual let us borrow these sockets so we could digitize them and indirectly assess change in residual limb size over time by calculating changes in socket volume and circumferences over time. Case Description and Methods: Over a decade, the subject maintained a relatively stable body weight of 84-88 kg and received nine sub-ischial sockets. The internal surface of each socket was scanned using a mechanical digitizer and volume and circumferences calculated. Findings and Outcomes: Socket volume increased 31.3%, from a low of 2659.2 cm 3 for the oldest socket to a high of 3490.6 cm 3 for the most recent socket. Proximal circumferences increased more than distal circumferences with a 15.9% total increase proximally versus 8.9% total increase distally. The results suggest that this individual's residual limb increased in size over time despite the compressive effect of the socket and liner. In addition, the increase in circumference was greater proximally than distally, which is where the remaining muscle bellies are located. Clinical relevance This case study provides insight into the long-term effect of the sub-ischial socket on residual limb volume given compression of the soft tissues by the socket system.

  6. Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation-Part 1: Description of technique

    PubMed Central

    Fatone, Stefania; Caldwell, Ryan

    2017-01-01

    Background: Current transfemoral prosthetic sockets restrict function, lack comfort, and cause residual limb problems. Lower proximal trim lines are an appealing way to address this problem. Development of a more comfortable and possibly functional subischial socket may contribute to improving quality of life of persons with transfemoral amputation. Objectives: The purpose of this study was to (1) describe the design and fabrication of a new subischial socket and (2) describe efforts to teach this technique. Study design: Development project. Methods: Socket development involved defining the following: subject and liner selection, residual limb evaluation, casting, positive mold rectification, check socket fitting, definitive socket fabrication, and troubleshooting of socket fit. Three hands-on workshops to teach the socket were piloted and attended by 30 certified prosthetists and their patient models. Results: Patient models responded positively to the comfort, range of motion, and stability of the new socket while prosthetists described the technique as “straight forward, reproducible.” Conclusion: To our knowledge, this is the first attempt to create a teachable subischial socket, and while it appears promising, more definitive evaluation is needed. Clinical relevance We developed the Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket as a more comfortable alternative to current transfemoral sockets and demonstrated that it could be taught successfully to prosthetists. PMID:28094686

  7. Dry Socket: Frequency, Clinical Picture, and Risk Factors in a Palestinian Dental Teaching Center

    PubMed Central

    Abu Younis, Mohammed H; Abu Hantash, Ra'ed O

    2011-01-01

    Aims: The objectives of this study were to find out the frequency, clinical picture, and risk factors of dry socket at the Dental Teaching Center of Al-Quds University in Palestine. Methods and Materials: Two previously used questionnaires were accomplished in this study over a one year period. The first questionnaire was completed for every patient who had one or more permanent teeth extracted in the Dental Surgery Clinic. The other one was completed for every patient suffered a postoperative pain and was diagnosed with dry socket. Results: There were 1305 dental extractions performed in 805 patients. The overall frequency of dry socket was 3.2%. The incidence of dry socket following non-surgical extractions was 1.7% while it was 15% following surgical extractions (P< 0.005). The incidence of dry socket was significantly higher in smokers (12%) than in non-smokers (4%) (P < 0.005), however, there is a strong association between the amount of smoking and the incidence of dry socket (P < 0.002). The incidence of dry socket was significantly higher in the single extraction cases (13%) than in the multiple extraction cases (5%) (P = 0.005). Age, sex, medical history, extraction site, amount of local anesthesia and experience of operator play no role in the occurrence of dry socket. Conclusion: Smoking, surgical trauma and single extractions are considered predisposing factors in the occurrence of dry socket. On the other hand, factors like: age, sex, medical history, extraction site, amount of anesthesia, and operator experience have no effect on the observation of dry socket. PMID:21559187

  8. Conservative Socket Regeneration with Buccal Wall Defect Using Guided Tissue.

    PubMed

    Al-Juboori, Mohammed Jasim

    2016-01-01

    Progressive alveolar bone resorption after tooth extraction may lead to surgical and prosthetic-driven difficulties, especially when deciding to use a dental implant to replace the extracted tooth. This case report discusses an irreparable lower left second premolar tooth with a periodontal lesion on the buccal side. A preservative tooth extraction was performed. Then, the socket was grafted with bovine bone, a collagen membrane was placed between the buccal bone and the attached gingiva, covering the bone dehiscence buccally, and the socket without a flap was raised. After a 6-month healing period, there was minimal socket width resorption and a shallow buccal vestibule. The implant was placed with high primary stability and sufficient buccal plate thickness. In conclusion, this guided tissue regeneration technique can minimize alveolar bone resorption in a socket with buccal dehiscence, but technical difficulties and shallowing of the buccal vestibule still exist.

  9. Laboratory-size three-dimensional water-window x-ray microscope with Wolter type I mirror optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohsuka, Shinji; The Graduate School for the Creation of New Photonics Industries, 1955-1 Kurematsu-cho, Nishi-ku, Hamamatsu-City, 431-1202; Ohba, Akira

    2016-01-28

    We constructed a laboratory-size three-dimensional water-window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques. It consists of an electron-impact x-ray source emitting oxygen Kα x-rays, Wolter type I grazing incidence mirror optics, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit better than 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm-scale three-dimensional fine structures were resolved.

  10. Enhanced water window x-ray emission from in situ formed carbon clusters irradiated by intense ultra-short laser pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakravarty, U.; Rao, B. S.; Arora, V.

    Enhanced water window x-ray emission (23–44 Å) from carbon clusters, formed in situ using a pre-pulse, irradiated by intense (I > 10{sup 17} W/cm{sup 2}) ultra-short laser pulse, is demonstrated. An order of magnitude x-ray enhancement over planar graphite target is observed in carbon clusters, formed by a sub-ns pre-pulse, interacting with intense main pulse after a delay. The effect of the delay and the duration of the main pulse is studied for optimizing the x-ray emission in the water window region. This x-ray source has added advantages of being an efficient, high repetition rate, and low debris x-ray source.

  11. BinMag: Widget for comparing stellar observed with theoretical spectra

    NASA Astrophysics Data System (ADS)

    Kochukhov, O.

    2018-05-01

    BinMag examines theoretical stellar spectra computed with Synth/SynthMag/Synmast/Synth3/SME spectrum synthesis codes and compare them to observations. An IDL widget program, BinMag applies radial velocity shift and broadening to the theoretical spectra to account for the effects of stellar rotation, radial-tangential macroturbulence, instrumental smearing. The code can also simulate spectra of spectroscopic binary stars by appropriate coaddition of two synthetic spectra. Additionally, BinMag can be used to measure equivalent width, fit line profile shapes with analytical functions, and to automatically determine radial velocity and broadening parameters. BinMag interfaces with the Synth3 (ascl:1212.010) and SME (ascl:1202.013) codes, allowing the user to determine chemical abundances and stellar atmospheric parameters from the observed spectra.

  12. Progress Toward Optimizing Prosthetic Socket Fit and Suspension Using Elevated Vacuum to Promote Residual Limb Health

    PubMed Central

    Wernke, Matthew M.; Schroeder, Ryan M.; Haynes, Michael L.; Nolt, Lonnie L.; Albury, Alexander W.; Colvin, James M.

    2017-01-01

    Objective: Prosthetic sockets are custom made for each amputee, yet there are no quantitative tools to determine the appropriateness of socket fit. Ensuring a proper socket fit can have significant effects on the health of residual limb soft tissues and overall function and acceptance of the prosthetic limb. Previous work found that elevated vacuum pressure data can detect movement between the residual limb and the prosthetic socket; however, the correlation between the two was specific to each user. The overall objective of this work is to determine the relationship between elevated vacuum pressure deviations and prosthetic socket fit. Approach: A tension compression machine was used to apply repeated controlled forces onto a residual limb model with sockets of different internal volume. Results: The vacuum pressure–displacement relationship was dependent on socket fit. The vacuum pressure data were sensitive enough to detect differences of 1.5% global volume and can likely detect differences even smaller. Limb motion was reduced as surface area of contact between the limb model and socket was maximized. Innovation: The results suggest that elevated vacuum pressure data provide information to quantify socket fit. Conclusions: This study provides evidence that the use of elevated vacuum pressure data may provide a method for prosthetists to quantify and monitor socket fit. Future studies should investigate the relationship between socket fit, limb motion, and limb health to define optimal socket fit parameters. PMID:28736683

  13. Postoperative Complications of Dermis-Fat Autografts in the Anophthalmic Socket.

    PubMed

    Starks, Victoria; Freitag, Suzanne K

    2018-01-01

    Reconstruction of the anophthalmic socket allows the use of an ocular prosthesis and rehabilitation of facial appearance. Dermis-fat grafting is one option in volume augmentation of the anophthalmic socket and presents unique benefits, including increased surface area within the socket and the ability to grow with pediatric patients. Postoperative complications of this procedure are relatively common. Minor complications, such as graft hirsutism, keratinization, and conjunctival cysts or granulomas, are managed easily by observation or simple intervention. Major complications, such as graft atrophy, infection, or ulceration, may prevent good prosthesis fit and may require return to the operating room.

  14. Clinical and histologic outcomes of calcium sulfate in the treatment of postextraction sockets.

    PubMed

    Ruga, Emanuele; Gallesio, Cesare; Chiusa, Luigi; Boffano, Paolo

    2011-03-01

    The aim of this prospective study was to assess the clinical and histologic outcomes obtained with calcium sulfate (CS) used as a filler material in fresh premolar and molar postextraction sockets. Sixty premolar or molar postextraction sockets were filled with CS. Among the 60 grafted sockets, after 3 months, 50 underwent implant placement and clinical assessment. The removal of a sample core of newly generated intrasocket tissue was performed in 19 sockets. Collected samples were sent for histologic examination. The percentage of vital bone, nonvital bone, residual CS, amorphous material, and connective areas in every sample was calculated and recorded. Fifty postextraction regenerated sockets that underwent implant placement 3 months after tooth removal were included in this study.A partial postoperative exposition of the graft was observed in 12 of 50 sockets. At the surgical reentry, the augmented extraction sockets were completely filled by a hard material with an adequate alveolar crest in 41 cases. Histologic examination of the cores revealed that 63.16% of the intrasocket tissue was new vital bone, 2.1% was nonvital bone, 4.74% was fibrous tissue, and 30% was amorphous material. No residual CS was identified in bone cores. This study confirmed that CS is an ideal grafting material. The clinical adequacy aspect of filled sockets at surgical reentry seemed to be indicative of a qualitatively better bone regeneration. Postoperative exposition of graft material after a first intervention seemed to constitute an important risk factor for a worse bone regeneration.

  15. Digitization of medical documents: an X-Windows application for fast scanning.

    PubMed

    Muñoz, A; Salvador, C H; Gonzalez, M A; Dueñas, A

    1992-01-01

    This paper deals with digitization, using a commercial scanner, of medical documents as still images for introduction into a computer-based Information System. Document management involves storing, editing and transmission. This task has usually been approached from the perspective of the difficulties posed by radiologic images because of their indisputable qualitative and quantitative significance. However, healthcare activities require the management of many other types of documents and involve the requirements of numerous users. One key to document management will be the availability of a digitizer to deal with the greatest possible number of different types of documents. This paper describes the relevant aspects of documents and the technical specifications that digitizers must fulfill. The concept of document type is introduced as the ideal set of digitizing parameters for a given document. The use of document type parameters can drastically reduce the time the user spends in scanning sessions. Presentation is made of an application based on Unix, X-Windows and OSF/Motif, with a GPIB interface, implemented around the document type concept. Finally, the results of the evaluation of the application are presented, focusing on the user interface, as well as on the viewing of color images in an X-Windows environment and the use of lossy algorithms in the compression of medical images.

  16. Development of a residuum/socket interface simulator for lower limb prosthetics.

    PubMed

    McGrath, Michael Paul; Gao, Jianliang; Tang, Jinghua; Laszczak, Piotr; Jiang, Liudi; Bader, Dan; Moser, David; Zahedi, Saeed

    2017-03-01

    Mechanical coupling at the interface between lower limb residua and prosthetic sockets plays an important role in assessing socket fitting and tissue health. However, most research lab-based lower limb prosthetic simulators to-date have implemented a rigid socket coupling. This study describes the fabrication and implementation of a lower limb residuum/socket interface simulator, designed to reproduce the forces and moments present during the key loading phases of amputee walking. An artificial residuum made with model bones encased in silicone was used, mimicking the compliant mechanical loading of a real residuum/socket interface. A 6-degree-of-freedom load cell measured the overall kinetics, having previously been incorporated into an amputee's prosthesis to collect reference data. The developed simulator was compared to a setup where a rigid pylon replaced the artificial residuum. A maximum uniaxial load of 850 N was applied, comparable to the peak vertical ground reaction force component during amputee walking. Load cell outputs from both pylon and residuum setups were compared. During weight acceptance, when including the artificial residuum, compression decreased by 10%, while during push off, sagittal bending and anterior-posterior shear showed a 25% increase and 34% decrease, respectively. Such notable difference by including a compliant residuum further highlighted the need for such an interface simulator. Subsequently, the simulator was adjusted to produce key load cell outputs briefly aligning with those from amputee walking. Force sensing resistors were deployed at load bearing anatomic locations on the residuum/socket interface to measure pressures and were compared to those cited in the literature for similar locations. The development of such a novel simulator provides an objective adjunct, using commonly available mechanical test machines. It could potentially be used to provide further insight into socket design, fit and the complex load

  17. Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses.

    PubMed

    Boone, David A; Kobayashi, Toshiki; Chou, Teri G; Arabian, Adam K; Coleman, Kim L; Orendurff, Michael S; Zhang, Ming

    2013-04-01

    Alignment - the process and measured orientation of the prosthetic socket relative to the foot - is important for proper function of a transtibial prosthesis. Prosthetic alignment is performed by prosthetists using visual gait observation and amputees' feedback. The aim of this study was to investigate the effect of transtibial prosthesis malalignment on the moments measured at the base of the socket: the socket reaction moments. Eleven subjects with transtibial amputation were recruited from the community. An instrumented prosthesis alignment component was used to measure socket reaction moments during ambulation under 17 alignment conditions, including nominally aligned using conventional clinical methods, and angle perturbations of 3° and 6° (flexion, extension, abduction, and adduction) and translation perturbations of 5mm and 10mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. Coronal alignment perturbations caused systematic changes in the coronal socket reaction moments. All angle and translation perturbations revealed statistically significant differences on coronal socket reaction moments compared to the nominal alignment at 30% and 75% of stance phase (P<0.05). The effect of sagittal alignment perturbations on sagittal socket reaction moments was not as responsive as that of the coronal perturbations. The sagittal angle and translation perturbations of the socket led to statistically significant changes in minimum moment, maximum moment, and moments at 45% of stance phase in the sagittal plane. Therefore, malalignment affected the socket reaction moments in amputees with transtibial prostheses. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Three-Dimensional Wiring for Extensible Quantum Computing: The Quantum Socket

    NASA Astrophysics Data System (ADS)

    Béjanin, J. H.; McConkey, T. G.; Rinehart, J. R.; Earnest, C. T.; McRae, C. R. H.; Shiri, D.; Bateman, J. D.; Rohanizadegan, Y.; Penava, B.; Breul, P.; Royak, S.; Zapatka, M.; Fowler, A. G.; Mariantoni, M.

    2016-10-01

    Quantum computing architectures are on the verge of scalability, a key requirement for the implementation of a universal quantum computer. The next stage in this quest is the realization of quantum error-correction codes, which will mitigate the impact of faulty quantum information on a quantum computer. Architectures with ten or more quantum bits (qubits) have been realized using trapped ions and superconducting circuits. While these implementations are potentially scalable, true scalability will require systems engineering to combine quantum and classical hardware. One technology demanding imminent efforts is the realization of a suitable wiring method for the control and the measurement of a large number of qubits. In this work, we introduce an interconnect solution for solid-state qubits: the quantum socket. The quantum socket fully exploits the third dimension to connect classical electronics to qubits with higher density and better performance than two-dimensional methods based on wire bonding. The quantum socket is based on spring-mounted microwires—the three-dimensional wires—that push directly on a microfabricated chip, making electrical contact. A small wire cross section (approximately 1 mm), nearly nonmagnetic components, and functionality at low temperatures make the quantum socket ideal for operating solid-state qubits. The wires have a coaxial geometry and operate over a frequency range from dc to 8 GHz, with a contact resistance of approximately 150 m Ω , an impedance mismatch of approximately 10 Ω , and minimal cross talk. As a proof of principle, we fabricate and use a quantum socket to measure high-quality superconducting resonators at a temperature of approximately 10 mK. Quantum error-correction codes such as the surface code will largely benefit from the quantum socket, which will make it possible to address qubits located on a two-dimensional lattice. The present implementation of the socket could be readily extended to accommodate a

  19. CAD/CAM transtibial prosthetic sockets from central fabrication facilities: How accurate are they?

    PubMed Central

    Sanders, Joan E.; Rogers, Ellen L.; Sorenson, Elizabeth A.; Lee, Gregory S.; Abrahamson, Daniel C.

    2014-01-01

    This research compares transtibial prosthetic sockets made by central fabrication facilities with their corresponding American Academy of Orthotists and Prosthetists (AAOP) electronic shape files and assesses the central fabrication process. We ordered three different socket shapes from each of 10 manufacturers. Then we digitized the sockets using a very accurate custom mechanical digitizer. Results showed that quality varied considerably among the different manufacturers. Four of the companies consistently made sockets within +/−1.1% volume (approximately 1 sock ply) of the AAOP electronic shape file, while six other companies did not. Six of the companies showed consistent undersizing or oversizing in their sockets, which suggests a consistent calibration or manufacturing error. Other companies showed inconsistent sizing or shape distortion, a difficult problem that represents a most challenging limitation for central fabrication facilities. PMID:18247236

  20. Survival Rate of Delayed Implants Placed in Healed Extraction Sockets is Significantly Higher Than That of Immediate Implants Placed in Fresh Extraction Sockets.

    PubMed

    Antetomaso, Jordan; Kumar, Satish

    2018-03-01

    Immediate implant placement into fresh extraction sockets versus delayed implants into healed sockets: a systematic review and meta-analysis. Mello CC, Lemos CAA, Verri FR, Dos Santos DM, Goiato MC, Pellizzer EP. Int J Oral Maxillofac Surg 2017; 46(9):1162-77. None TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Thick-SOI Echelle grating for any-to-any wavelength routing interconnection in multi-socket computing environments

    NASA Astrophysics Data System (ADS)

    Dabos, G.; Pitris, S.; Mitsolidou, C.; Alexoudi, T.; Fitsios, D.; Cherchi, M.; Harjanne, M.; Aalto, T.; Kanellos, G. T.; Pleros, N.

    2017-02-01

    As data centers constantly expand, electronic switches are facing the challenge of enhanced scalability and the request for increased pin-count and bandwidth. Photonic technology and wavelength division multiplexing have always been a strong alternative for efficient routing and their potential was already proven in the telecoms. CWDM transceivers have emerged in the board-to-board level interconnection, revealing the potential for wavelength-routing to be applied in the datacom and an AWGR-based approach has recently been proposed towards building an optical multi-socket interconnection to offer any-to-any connectivity with high aggregated throughput and reduced power consumption. Echelle gratings have long been recognized as the multiplexing block exhibiting smallest footprint and robustness in a wide number of applications compared to other alternatives such as the Arrayed Waveguide Grating. Such filtering devices can also perform in a similar way to cyclical AWGR and serve as mid-board routing platforms in multi-socket environments. In this communication, we present such a 3x3 Echelle grating integrated on thick SOI platform with aluminum-coated facets that is shown to perform successful wavelength-routing functionality at 10 Gb/s. The device exhibits a footprint of 60x270 μm2, while the static characterization showed a 3 dB on-chip loss for the best channel. The 3 dB-bandwidth of the channels was 4.5 nm and the free spectral range was 90 nm. The echelle was evaluated in a 2x2 wavelength routing topology, exhibiting a power penalty of below 0.4 dB at 10-9 BER for the C-band. Further experimental evaluations of the platform involve commercially available CWDM datacenter transceivers, towards emulating an optically-interconnected multi-socket environment traffic scenario.

  2. Advanced water window x-ray microscope design and analysis

    NASA Technical Reports Server (NTRS)

    Shealy, D. L.; Wang, C.; Jiang, W.; Lin, J.

    1992-01-01

    The project was focused on the design and analysis of an advanced water window soft-x-ray microscope. The activities were accomplished by completing three tasks contained in the statement of work of this contract. The new results confirm that in order to achieve resolutions greater than three times the wavelength of the incident radiation, it will be necessary to use aspherical mirror surfaces and to use graded multilayer coatings on the secondary (to accommodate the large variations of the angle of incidence over the secondary when operating the microscope at numerical apertures of 0.35 or greater). The results are included in a manuscript which is enclosed in the Appendix.

  3. Management of Radiation-induced Severe Anophthalmic Socket Contracture in Patients with Uveal Melanoma

    PubMed Central

    Nasser, Qasiem J.; Gombos, Dan S.; Williams, Michelle D.; Guadagnolo, B. Ashleigh; Morrison, William H.; Garden, Adam S.; Beadle, Beth M.; Canseco, Elvia; Esmaeli, Bita

    2012-01-01

    Purpose High-dose radiotherapy can cause contracture of the anophthalmic socket, but the incidence of this complication in patients with enucleation for uveal melanoma has not previously been reported. We reviewed the surgical management and outcomes in terms of successful prosthesis wear in patients with severe contracture of the anophthalmic socket treated with high-dose radiotherapy for high-risk uveal melanoma and estimated the relative risk of this complication. Methods The medical records of all consecutive patients enrolled in a prospective uveal-melanoma tissue-banking protocol at our institution who underwent enucleation between January 2003 and December 2010 were reviewed. Patients who underwent adjuvant radiotherapy of the enucleated socket were further studied. Results Of the 68 patients enrolled in the prospective tissue banking protocol, 12 had high-risk histologic features (e.g., extrascleral spread or vortex vein invasion) and were treated with 60 Gy of external-beam radiotherapy after enucleation. Five of these patients (41.7%) experienced severe socket contracture precluding prosthesis wear. The median time to onset of contracture following completion of radiotherapy was 20 months. Three patients underwent surgery, which entailed scar tissue release, oral mucous membrane grafting, and socket reconstruction; 2 patients declined surgery. All 3 patients who had surgery experienced significant improvement of socket contracture that enabled patients to wear a prosthesis again. Conclusion High-dose radiotherapy after enucleation in patients with uveal melanoma caused severe socket contracture and inability to wear a prosthesis in approximately 40% of patients. Surgical repair of the contracted socket using oral mucous membrane grafting can allow resumption of prosthesis wear. PMID:22581085

  4. The Ozone Widget Framework: towards modularity of C2 human interfaces

    NASA Astrophysics Data System (ADS)

    Hellar, David Benjamin; Vega, Laurian C.

    2012-05-01

    The Ozone Widget Framework (OWF) is a common webtop environment for distribution across the enterprise. A key mission driver for OWF is to enable rapid capability delivery by lowering time-to-market with lightweight components. OWF has been released as Government Open Source Software and has been deployed in a variety of C2 net-centric contexts ranging from real-time analytics, cyber-situational awareness, to strategic and operational planning. This paper discusses the current and future evolution of OWF including the availability of the OZONE Marketplace (OMP), useractivity driven metrics, and architecture enhancements for accessibility. Together, OWF is moving towards the rapid delivery of modular human interfaces supporting modern and future command and control contexts.

  5. Searching for O-X-B mode-conversion window with monitoring of stray microwave radiation in LHD

    NASA Astrophysics Data System (ADS)

    Igami, H.; Kubo, S.; Laqua, H. P.; Nagasaki, K.; Inagaki, S.; Notake, T.; Shimozuma, T.; Yoshimura, Y.; Mutoh, T.; LHD Experimental Group

    2006-10-01

    In the Large Helical Device, the stray microwave radiation is monitored by using so-called sniffer probes during electron cyclotron heating. In monitoring the stray radiation, we changed the microwave beam injection angle and search the O-X-B mode-conversion window to excite electron Bernstein waves (EBWs). When the microwave beam is injected toward the vicinity of the predicted O-X-B mode-conversion window, the electron temperature rises in the central part of overdense plasmas. In that case, the stray radiation level near the injection antenna becomes low. These results indicate that monitoring the stray radiation near the injection antenna is helpful in confirming the effectiveness of excitation of EBWs simply without precise analysis.

  6. Extraction socket sealing using palatal gingival grafts and resorbable collagen membranes.

    PubMed

    Kim, Sang-Yun; Kim, Young-Kyun; Kim, Hyun-Suk; Yun, Pil-Young; Kim, Su-Gwan; Choi, Yong-Hun

    2017-12-01

    Socket sealing surgery is performed for the preservation of the form and volume of the soft tissue by covering the resulting socket with autogenous soft tissue graft or membrane barriers. This procedure is usually necessary to improve the esthetic results of the maxillary anterior or premolar areas. This study retrospectively investigated cases involving the open membrane technique or socket sealing surgery with a palatal gingival graft or collagen membrane where implant placement and bone grafting were performed immediately after tooth extraction. From January 2005 to December 2008, socket sealing surgery was performed in 24 patients, and 25 implants were placed. All implants were successful in the follow-up period. In the palatal gingival graft group, the mean marginal bone loss was 1.17 mm during the mean follow-up period of 81.0 months. In the collagen membrane group, the mean marginal bone loss was 1.23 mm during the mean follow-up period of 76.9 months. There was no significant difference between the two groups. Consequently, socket sealing surgery is effective at minimizing the loss of soft tissue and alveolar bone.

  7. Integration in PACS of DICOM with TCP/IP, SQL, and X Windows

    NASA Astrophysics Data System (ADS)

    Reijns, Gerard L.

    1994-05-01

    The DICOM standard (Digital Imaging and Communications in Medicine) has been developed in order to obtain compatibility at the higher OSI levels. This paper describes the implementation of DICOM into our developed low cost PACS, which uses as much as possible standard software and standard protocols such as SQL, X Windows and TCP/IP. We adopted the requirement that all messages on the communication network have to be DICOM compatible. The translation between DICOM messages and SQL commands, which drive the relational data base, has been accommodated in our PACS supervisor. The translation takes only between 10 and 20 milliseconds. Images, that will be used the current day are stored in a distributed, parallel operating image base for reasons of performance. Extensive use has been made of X Windows to visualize images. A maximum of 12 images can simultaneously be displayed, of which one selected image can be manipulated (e.g., magnified, rotated, etc.), without affecting the other displayed images. The emphasis of the future work will be on performance measurements and modeling of our PACS and bringing the results of both methods in agreement with each other.

  8. Fluctuating residual limb volume accommodated with an adjustable, modular socket design: A novel case report.

    PubMed

    Mitton, Kay; Kulkarni, Jai; Dunn, Kenneth William; Ung, Anthony Hoang

    2017-10-01

    This novel case report describes the problems of prescribing a prosthetic socket in a left transfemoral amputee secondary to chronic patellofemoral instability compounded by complex regional pain syndrome. Case Description and Methods: Following the amputation, complex regional pain syndrome symptoms recurred in the residual limb, presenting mainly with oedema. Due to extreme daily volume fluctuations of the residual limb, a conventional, laminated thermoplastic socket fitting was not feasible. Findings and Outcomes: An adjustable, modular socket design was trialled. The residual limb volume fluctuations were accommodated within the socket. Amputee rehabilitation could be continued, and the rehabilitation goals were achieved. The patient was able to wear the prosthesis for 8 h daily and to walk unaided indoors and outdoors. An adjustable, modular socket design accommodated the daily residual limb volume fluctuations and provided a successful outcome in this case. It demonstrates the complexities of socket fitting and design with volume fluctuations. Clinical relevance Ongoing complex regional pain syndrome symptoms within the residual limb can lead to fitting difficulties in a conventional, laminated thermoplastic socket due to volume fluctuations. An adjustable, modular socket design can accommodate this and provide a successful outcome.

  9. A case series of anophthalmic socket cysts excised utilising fibrin sealant.

    PubMed

    Wong, Yun; Clarke, Lucy; Lau, Gordon

    2017-10-23

    Anophthalmic socket cysts are challenging to remove and incomplete excision has been shown to increase the risk of recurrence. This case series describes a novel technique utilising the fibrin sealant Tisseel (Baxter AG, Vienna, Austria) to retain the socket cyst integrity during surgical removal to facilitate its complete excision. Five patients were included and followed up for a minimum of 1 year, and there were no signs of recurrence in any of the cases. The surgical technique is described and illustrated. This technique is a safe way of simplifying challenging socket cyst surgery.

  10. Evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin

    PubMed Central

    Tumer, Celal; Ugur, Omer; Vatankulu, Betul

    2015-01-01

    Objective: The aim of this study was to determine whether the use of platelet rich fibrin (PRF) improved the healing of extraction sockets. Study Design: A total of 20 patients with bilateral soft tissue impacted mandibular third molars were included in this study. The left and right third molars were extracted during the same session. Subsequently, the PRF membrane was randomly administered to one of the extraction sockets, whereas the contra lateral sockets were left without treatment. On postoperative 30. and 90. days, panoramic images and bone scintigrams were taken to evaluate the bone healing between PRF-treated and non-PRF-treated sockets. Also, periodontal evaluation was performed in the same control sessions. Dependent group t test for paired samples was used for statistical analysis. Results: The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 30 and 90 days post operatively. Radio opacity that can show the bone healing on panoramic images were measured by Image J programmer and they did not differ significantly. Also periodontal values did not differ significantly. Conclusions: PRF might not lead to enhanced bone healing in impacted mandibular third molar extraction sockets 30 and 90 days after surgery. It is thought that PRF has the potential characteristics of an autologous fibrin matrix and can accelerate the healing. To better understand the effects of PRF on healing, further research is warranted with larger sample sizes. Key words:PRF, scintigraphy, healing, extraction sockets. PMID:25475771

  11. Surface EMG and intra-socket force measurement to control a prosthetic device

    NASA Astrophysics Data System (ADS)

    Sanford, Joe; Patterson, Rita; Popa, Dan

    2015-06-01

    Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.

  12. Static and dynamic pressure prediction for prosthetic socket fitting assessment utilising an inverse problem approach.

    PubMed

    Sewell, Philip; Noroozi, Siamak; Vinney, John; Amali, Ramin; Andrews, Stephen

    2012-01-01

    It has been recognised in a review of the developments of lower-limb prosthetic socket fitting processes that the future demands new tools to aid in socket fitting. This paper presents the results of research to design and clinically test an artificial intelligence approach, specifically inverse problem analysis, for the determination of the pressures at the limb/prosthetic socket interface during stance and ambulation. Inverse problem analysis is based on accurately calculating the external loads or boundary conditions that can generate a known amount of strain, stresses or displacements at pre-determined locations on a structure. In this study a backpropagation artificial neural network (ANN) is designed and validated to predict the interfacial pressures at the residual limb/socket interface from strain data collected from the socket surface. The subject of this investigation was a 45-year-old male unilateral trans-tibial (below-knee) traumatic amputee who had been using a prosthesis for 22 years. When comparing the ANN predicted interfacial pressure on 16 patches within the socket with actual pressures applied to the socket there is shown to be 8.7% difference, validating the methodology. Investigation of varying axial load through the subject's prosthesis, alignment of the subject's prosthesis, and pressure at the limb/socket interface during walking demonstrates that the validated ANN is able to give an accurate full-field study of the static and dynamic interfacial pressure distribution. To conclude, a methodology has been developed that enables a prosthetist to quantitatively analyse the distribution of pressures within the prosthetic socket in a clinical environment. This will aid in facilitating the "right first time" approach to socket fitting which will benefit both the patient in terms of comfort and the prosthetist, by reducing the time and associated costs of providing a high level of socket fit. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. [Tissue engineered bone scaffold material in restoration of alveolar socket after extraction of lower impacted third molar].

    PubMed

    Chen, Zhi-fang

    2011-02-01

    To investigate the effects of tissue engineered bone scaffold material in the restoration of alveolar socket after extraction of lower impacted third molar. Thirteen patients were immediately implanted with Bio-oss or PerioGlas® in the alveolar cavity after impacted mandibular third molar extraction. Clinical observation and X-ray were taken 1 to 12 weeks after operation. Paired t test was used for statistical analysis by SPSS10.0 software package. Thirteen patients did not experience postoperative complications. The distal alveolar height of the second molar and the gingival attachment did decrease significantly 1 to 12 weeks after operation(P < 0.05). Tissue engineered bone scaffold material is helpful in the restoration of alveolar socket after impacted third molar extraction.

  14. Histomorphometric evaluation of a calcium-phosphosilicate putty bone substitute in extraction sockets.

    PubMed

    Kotsakis, Georgios A; Joachim, Frederic P C; Saroff, Stephen A; Mahesh, Lanka; Prasad, Hari; Rohrer, Michael D

    2014-01-01

    The objective of this study was to evaluate bone regeneration in 24 sockets grafted with a calcium phosphosilicate putty alloplastic bone substitute. A core was obtained from 17 sockets prior to implant placement for histomorphometry at 5 to 6 months postextraction. Radiographic analysis during the same postextraction healing period showed radiopaque tissue in all sockets. Histomorphometric analysis revealed a mean vital bone content of 31.76% (± 14.20%) and residual graft content of 11.47% (± 8.99%) after a mean healing period of 5.7 months. The high percentage of vital bone in the healed sites in combination with its timely absorption rate suggest that calcium phosphosilicate putty can be a reliable choice for osseous regeneration in extraction sockets.

  15. The X-windows interactive navigation data editor

    NASA Technical Reports Server (NTRS)

    Rinker, G. C.

    1992-01-01

    A new computer program called the X-Windows Interactive Data Editor (XIDE) was developed and demonstrated as a prototype application for editing radio metric data in the orbit-determination process. The program runs on a variety of workstations and employs pull-down menus and graphical displays, which allow users to easily inspect and edit radio metric data in the orbit data files received from the Deep Space Network (DSN). The XIDE program is based on the Open Software Foundation OSF/Motif Graphical User Interface (GUI) and has proven to be an efficient tool for editing radio metric data in the navigation operations environment. It was adopted by the Magellan Navigation Team as their primary data-editing tool. Because the software was designed from the beginning to be portable, the prototype was successfully moved to new workstation environments. It was also itegrated into the design of the next-generation software tool for DSN multimission navigation interactive launch support.

  16. Individual responses to alignment perturbations in socket reaction moments while walking in transtibial prostheses.

    PubMed

    Kobayashi, Toshiki; Orendurff, Michael S; Zhang, Ming; Boone, David A

    2014-05-01

    The alignment of transtibial prostheses has a systematic effect on the mean socket reaction moments in amputees. However, understanding their individual differences in response to alignment perturbations is also important for prosthetists to fully utilize the socket reaction moments for dynamic alignment in each unique patient. The aim of this study was to investigate individual responses to alignment perturbations in transtibial prostheses with solid-ankle-cushion-heel feet. A custom instrumented prosthesis alignment component was used to measure the socket reaction moments while walking in 11 amputees with transtibial prostheses under 17 alignment conditions, including 3° and 6° of flexion, extension, abduction, and adduction of the socket, 5mm and 10mm of anterior, posterior, lateral, and medial translation of the socket, and an initial baseline alignment. Coronal moments at 30% of stance and maximum sagittal moments were extracted for comparisons from each amputee. In the coronal plane, varus moment at 30% of stance was generally reduced by adduction or medial translation of the socket in all the amputees. In the sagittal plane, extension moment was generally increased by posterior translation or flexion of the socket; however, this was not necessarily the case for all the amputees. Individual responses to alignment perturbations are not always consistent, and prosthetists would need to be aware of this variance when addressing individual socket reaction moments during dynamic alignment in clinical setting. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Systematic review of effects of current transtibial prosthetic socket designs--Part 2: Quantitative outcomes.

    PubMed

    Safari, Mohammad Reza; Meier, Margrit Regula

    2015-01-01

    This review is an attempt to untangle the complexity of transtibial prosthetic socket fit and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. In addition, we identified knowledge gaps, thus providing direction for possible future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, using medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design and type of outcome measure used. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that included the Downs and Black risk of bias assessment checklist. This article presents the results from the systematic review of the quantitative outcomes (n = 27 articles). Trends indicate that vacuum-assisted suction sockets improve gait symmetry, volume control, and residual limb health more than other socket designs. Hydrostatic sockets seem to create less inconsistent socket fittings, reducing a problem that greatly influences outcome measures. Knowledge gaps exist in the understanding of clinically meaningful changes in socket fit and its effect on biomechanical outcomes. Further, safe and comfortable pressure thresholds under various conditions should be determined through a systematic approach.

  18. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.

    PubMed

    Zhang, Linlin; Zhu, Ming; Shen, Ling; Zheng, Feng

    2013-01-01

    Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.

  19. Prosthetic Rehabilitation Following Socket Reconstruction with Blair-Brown Graft and Conformer Therapy for Management of Severe Post-Enucleation Socket Syndrome--A Clinical Report.

    PubMed

    Aggarwal, Himanshi; Singh, Saumyendra V; Kumar, Pradeep; Kumar Singh, Arun

    2015-06-01

    One of the most common tumors of the eye diagnosed in childhood is retinoblastoma, which mandates enucleation with adjunctive chemotherapy and radiotherapy to save the patient's life. The most common late enucleation complication is post-enucleation socket syndrome (PESS), which poses a management dilemma for the prosthodontist and surgeon, along with being a major esthetic concern for the patient. The reconstruction of such sockets is complex. The purpose of this clinical report is to describe the rehabilitation of such a pediatric patient with severe PESS. The patient was successfully rehabilitated by presurgical conformer therapy, socket reconstruction surgery with non-meshed intermediate split thickness skin graft (STSG)/Blair-Brown graft, and postsurgical conformer stent. This was followed by fabrication of a custom ocular prosthesis, to achieve favorable functional, physical, and psychological effects. © 2014 by the American College of Prosthodontists.

  20. [Use of "gelatamp" colloidal silver gelatin sponge to prevent dry socket after extracting mandibular impacted teeth].

    PubMed

    Wang, Yao-zhong; Guan, Qun-li; Li, Ya-xin; Guo, Ji-lai; Jiang, Ling; Jia, Mu-yun; Deng, Yue

    2013-02-01

    To study the clinical effect of "gelatamp" colloidal silver gelatin sponge on preventing dry socket after extracting the mandibular impacted teeth. 1350 teeth extracted from 976 patients who needed to extract the mandibular impacted teeth were divided into group A, group B and group C randomly. "Gelatamp" colloidal silver gelatin sponge was implanted into alveolar socket after teeth extraction in group A, with absorbable gelatin sponge was implanted into alveolar socket in group B and nothing was implanted into alveolar socket in group C. The incidence of dry socket was observed, the data was analyzed using SPSS10.0 software package. The incidence of dry socket was 0.44% in group A, 2% in group B and 4.44% in group C. There was significant difference in the incidence of dry socket between group A and group C(P<0.01). There was also significant difference between group B and group C(P<0.05) and between group A and group B(P<0.05). The results demonstrate that "gelatamp" colloidal silver gelatin sponge can prevent the occurrence of dry socket after teeth extraction, which is of wide clinical use.

  1. Evaluation of Contact Separation Force Testing as a Screening Methodology for Electrical Socket Contacts

    NASA Technical Reports Server (NTRS)

    Green, Chris; Greenwell, Chris; Brusse, jay; Krus, Dennis; Leidecker, Henning

    2009-01-01

    During system level testing intermittent and permanent open circuit failures of mated, crimp removable, electrical contact pairs were experienced. The root cause of the failures was determined to be low (but not zero) contact forces applied by the socket contact tines against the engaging pin. The low contact force reduces the effectiveness of the wiping action of the socket tines against the pin. The observed failure mode may be produced when insufficient wiping during mate, demate and small relative movement in use allows for the accumulation of debris or insulating films that electrically separate the contact pair. The investigation identified at least three manufacturing process control problems associated with the socket contacts that enabled shipment of contacts susceptible to developing low contact forces: (1) Improper heat treatment of the socket tines resulting in plastic rather than elastic behavior; (2) Overly thinned socket tines at their base resulting in reduced pin retention forces; (3) insufficient screening tests to identify parts susceptible to the aforementioned failure mechanisms. The results from an extensive screening program of socket contacts utilizing the industry standard contact separation force test procedures are described herein. The investigation shows this method to be capable of identifying initially weak sockets. However, sockets whose contact retention forces may degrade during use may not be screened out by pin retention testing alone. Further investigations are required to correlate low contact retention forces with increased electrical contact resistance in the presence of insulating films that may accumulate in the use environment.

  2. Sequential healing of open extraction sockets. An experimental study in monkeys.

    PubMed

    Scala, Alessandro; Lang, Niklaus P; Schweikert, Michael T; de Oliveira, José Américo; Rangel-Garcia, Idelmo; Botticelli, Daniele

    2014-03-01

    To describe the sequential healing of open extraction sockets at which no attempts to obtain a primary closure of the coronal access to the alveolus have been made. The third mandibular premolar was extracted bilaterally in 12 monkeys, and no sutures were applied to close the wound. The healing after 4, 10, 20, 30, 90 and 180 days was morphometrically studied. After 4 days of healing, a blood clot mainly occupied the extraction sockets, with the presence of an inflammatory cells' infiltrate. A void was confined in the central zones of the coronal and middle regions, in continuity with the entrance of the alveoli. At 10 days, the alveolus was occupied by a provisional matrix, with new bone formation lining the socket bony walls. At 20 days, the amount of woven bone was sensibly increasing. At 30 days, the alveolar socket was mainly occupied by mineralized immature bone at different stages of healing. At 90 and 180 days, the amount of mineralized bone decreased and substituted by trabecular bone and bone marrow. Bundle bone decreased from 95.5% at 4 days to 7.6% at 180 days, of the whole length of the inner alveolar surface. Modeling processes start from the lateral and apical walls of the alveolus, leading to the closure of the socket with newly formed bone within a month from extraction. Remodeling processes will follow the previous stages, resulting in trabecular and bone marrow formation and in a corticalization of the socket access. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  3. Evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin.

    PubMed

    Baslarli, Ozgur; Tumer, Celal; Ugur, Omer; Vatankulu, Betul

    2015-01-01

    The aim of this study was to determine whether the use of platelet rich fibrin (PRF) improved the healing of extraction sockets. A total of 20 patients with bilateral soft tissue impacted mandibular third molars were included in this study. The left and right third molars were extracted during the same session. Subsequently, the PRF membrane was randomly administered to one of the extraction sockets, whereas the contralateral sockets were left without treatment. On postoperative 30. and 90. days, panoramic images and bone scintigrams were taken to evaluate the bone healing between PRF-treated and non-PRF-treated sockets. Also, periodontal evaluation was performed in the same control sessions. Dependent group t test for paired samples was used for statistical analysis. The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 30 and 90 days postoperatively. Radio-opacity that can show the bone healing on panoramic images were measured by Image J programme and they did not differ significantly. Also periodontal values did not differ significantly. PRF might not lead to enhanced bone healing in impacted mandibular third molar extraction sockets 30 and 90 days after surgery. It is thought that PRF has the potential characteristics of an autologous fibrin matrix and can accelerate the healing. To better understand the effects of PRF on healing, further research is warranted with larger sample sizes.

  4. Alveolar socket preservation with demineralised bovine bone mineral and a collagen matrix

    PubMed Central

    2017-01-01

    Purpose The aim of the present study was to evaluate the healing of post-extraction sockets following alveolar ridge preservation clinically, radiologically, and histologically. Methods Overall, 7 extraction sockets in 7 patients were grafted with demineralised bovine bone mineral and covered with a porcine-derived non-crosslinked collagen matrix (CM). Soft tissue healing was clinically evaluated on the basis of a specific healing index. Horizontal and vertical ridge dimensional changes were assessed clinically and radiographically at baseline and 6 months after implant placement. For histological and histomorphometric analysis, bone biopsies were harvested from the augmented sites during implant surgery 6 months after the socket preservation procedure. Results Clinically, healing proceeded uneventfully in all the sockets. A trend towards reduced horizontal and vertical socket dimensions was observed from baseline to the final examination. The mean width and height of resorption were 1.21 mm (P=0.005) and 0.46 mm (P=0.004), respectively. Histologically, residual xenograft particles (31.97%±3.52%) were surrounded by either newly formed bone (16.02%±7.06%) or connective tissue (50.67%±8.42%) without fibrous encapsulation. The CM underwent a physiological substitution process in favour of well-vascularised collagen-rich connective tissue. Conclusions Socket preservation using demineralised bovine bone mineral in combination with CM provided stable dimensional changes of the alveolar ridge associated with good re-epithelialisation of the soft tissues during a 6-month healing period. PMID:28861284

  5. Technical Note: Computer-Manufactured Inserts for Prosthetic Sockets

    PubMed Central

    Sanders, Joan E.; McLean, Jake B.; Cagle, John C.; Gardner, David W.; Allyn, Katheryn J.

    2016-01-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant’s test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11 mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03 mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. PMID:27212209

  6. Technical note: Computer-manufactured inserts for prosthetic sockets.

    PubMed

    Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J

    2016-08-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. HOW DOES ADDING AND REMOVING LIQUID FROM SOCKET BLADDERS AFFECT RESIDUAL LIMB FLUID VOLUME?

    PubMed Central

    Sanders, JE; Cagle, JC; Harrison, DS; Myers, TR; Allyn, KJ

    2015-01-01

    Adding and removing liquid from socket bladders is a means for people with limb loss to accommodate residual limb volume change. Nineteen people with trans-tibial amputation using their regular prosthetic socket fitted with fluid bladders on the inside socket surface underwent cycles of bladder liquid addition and removal. In each cycle, subjects sat, stood, and walked for 90s with bladder liquid added and then sat, stood, and walking for 90s again with the bladder liquid removed. The amount of bladder liquid added was increased in each cycle. Bioimpedance analysis was implemented to measure residual limb fluid volume. Results showed that the preferred bladder liquid volume was 16.8 mL (s.d.8.4), corresponding to 1.7% (s.d.0.8%) of the average socket volume between the bioimpedance voltage-sensing electrodes. Limb fluid volume driven out of the residual limb when bladder liquid was added was typically not recovered upon subsequent bladder liquid removal. Fifteen of nineteen subjects experienced a gradual limb fluid volume loss over the test session. Care should be taken when implementing adjustable socket technologies in people with limb amputation. Reducing socket volume may accentuate limb fluid volume loss. PMID:24203546

  8. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique.

    PubMed

    Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.

  9. Laboratory-size three-dimensional x-ray microscope with Wolter type I mirror optics and an electron-impact water window x-ray source

    NASA Astrophysics Data System (ADS)

    Ohsuka, Shinji; Ohba, Akira; Onoda, Shinobu; Nakamoto, Katsuhiro; Nakano, Tomoyasu; Miyoshi, Motosuke; Soda, Keita; Hamakubo, Takao

    2014-09-01

    We constructed a laboratory-size three-dimensional water window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques, and observed bio-medical samples to evaluate its applicability to life science research fields. It consists of a condenser and an objective grazing incidence Wolter type I mirror, an electron-impact type oxygen Kα x-ray source, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit of around 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm scale three-dimensional fine structures were resolved.

  10. Laboratory-size three-dimensional x-ray microscope with Wolter type I mirror optics and an electron-impact water window x-ray source.

    PubMed

    Ohsuka, Shinji; Ohba, Akira; Onoda, Shinobu; Nakamoto, Katsuhiro; Nakano, Tomoyasu; Miyoshi, Motosuke; Soda, Keita; Hamakubo, Takao

    2014-09-01

    We constructed a laboratory-size three-dimensional water window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques, and observed bio-medical samples to evaluate its applicability to life science research fields. It consists of a condenser and an objective grazing incidence Wolter type I mirror, an electron-impact type oxygen Kα x-ray source, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit of around 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm scale three-dimensional fine structures were resolved.

  11. Case study: survey of patient satisfaction with prosthesis quality and design among below-knee prosthetic leg socket users.

    PubMed

    Mohd Hawari, Nurhanisah; Jawaid, Mohammad; Md Tahir, Paridah; Azmeer, Raja Ahmad

    2017-11-01

    The aim of this case study was to explore patient satisfaction with the quality of prosthetic leg sockets intended for persons with lower limb amputations. A qualitative study based on in-depth interviews, preceded by a questionnaire session, was carried out with patients from the Rehabilitation Center and Hospital in Malaysia. Twelve out-patient and in-patient amputees with lower limb amputations, specifically below-knee amputations, were chosen randomly. The analysis of patients' narratives aimed to identify the functional and esthetic characteristics of currently used prosthetic leg sockets and any problems related to them. The obtained results indicated that out of the 12 participants, 41.7% and 25% were satisfied and somewhat satisfied with their current prosthetic sockets. Durability and comfort were rated by the participants as the most important characteristics of prosthetic sockets, with 83.3%. As regards the esthetic appearance of the socket, 66.7% of the respondents considered that the most important feature was the material from which the socket was fabricated. Thus, we conclude that current satisfaction levels with the quality of prosthetic sockets among amputees in Malaysia are suitable, prosthesis being preferred by many amputees. The results can be used to direct future research on cosmesis and functionality of prosthetic socket design. Implications for Rehabilitation Case study will help participants to get cost effective prosthetic leg socket. Develop prosthetic leg socket comfortable as comparative to existing one. Help Malaysian government to make policy to develop local prosthetic leg socket at affordable price.

  12. Characterisation of dynamic couplings at lower limb residuum/socket interface using 3D motion capture.

    PubMed

    Tang, Jinghua; McGrath, Michael; Laszczak, Piotr; Jiang, Liudi; Bader, Dan L; Moser, David; Zahedi, Saeed

    2015-12-01

    Design and fitting of artificial limbs to lower limb amputees are largely based on the subjective judgement of the prosthetist. Understanding the science of three-dimensional (3D) dynamic coupling at the residuum/socket interface could potentially aid the design and fitting of the socket. A new method has been developed to characterise the 3D dynamic coupling at the residuum/socket interface using 3D motion capture based on a single case study of a trans-femoral amputee. The new model incorporated a Virtual Residuum Segment (VRS) and a Socket Segment (SS) which combined to form the residuum/socket interface. Angular and axial couplings between the two segments were subsequently determined. Results indicated a non-rigid angular coupling in excess of 10° in the quasi-sagittal plane and an axial coupling of between 21 and 35 mm. The corresponding angular couplings of less than 4° and 2° were estimated in the quasi-coronal and quasi-transverse plane, respectively. We propose that the combined experimental and analytical approach adopted in this case study could aid the iterative socket fitting process and could potentially lead to a new socket design. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Design of rock socketed drilled shafts

    DOT National Transportation Integrated Search

    1998-09-01

    Three field load tests of drilled shafts socketed in Burlington limestone were conducted using the Osterberg load cell. The objective of these tests was to compare the shaft capacities obtained from the field load tests with capacities predicted usin...

  14. A retrospective study on the use of a dental dressing to reduce dry socket incidence in smokers.

    PubMed

    Murph, James T; Jaques, Susan H; Knoell, Alexander N; Archibald, Geoffrey D; Yang, Stan

    2015-01-01

    This study assessed the effectiveness of using an oxidized cellulose dental dressing in order to reduce the rate of alveolar osteitis after posterior tooth extraction in smokers. Dry socket incidences of heavy smokers from 4 independent dental clinics, which routinely used oxidized cellulose dental dressings to mitigate dry socket formation between March 2011 and December 2012, were compiled and evaluated. All extraction sites healed uneventfully except for those cases that developed dry sockets. Overall, 1.7% of male patients and 2.2% of female patients developed dry sockets. No conclusive relationship was found between the number of cigarettes smoked and dry socket formation among patients in this study. The results of this study were consistent with the view that gender, age, postextraction regimen, and multiple extractions affect dry socket formation. The results indicate that an oxidized cellulose dental dressing postextraction is a safe and effective method for mitigating dry socket formation among smokers.

  15. Parathyroid hormone related to bone regeneration in grafted and nongrafted tooth extraction sockets in rats.

    PubMed

    Kuroshima, Shinichiro; Al-Salihi, Zeina; Yamashita, Junro

    2013-02-01

    The quality and quantity of bone formed in tooth extraction sockets impact implant therapy. Therefore, the establishment of a new approach to enhance bone formation and to minimize bone resorption is important for the success of implant therapy. In this study, we investigated whether intermittent parathyroid hormone (PTH) therapy enhanced bone formation in grafted sockets. Tooth extractions of the maxillary first molars were performed in rats, and the sockets were grafted with xenograft. Intermittent PTH was administered either for 7 days before extractions, for 14 days after extractions, or both. The effect of PTH therapy on bone formation in the grafted sockets was assessed using microcomputed tomography at 14 days after extractions. PTH therapy for 7 days before extractions was not effective to augment bone fill, whereas PTH therapy for 14 days after operation significantly augmented bone formation in the grafted sockets. Intermittent PTH therapy starting right after tooth extractions significantly enhanced bone fill in the grafted sockets, suggesting that PTH therapy can be a strong asset for the success of the ridge preservation procedure.

  16. Functional Performance Evaluation of the Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket for Persons with Transfemoral Amputation

    DTIC Science & Technology

    2016-10-01

    satisfaction with device’’ (i.e. prosthesis) than the IC Socket. During year 1, we received all required IRB approvals, registered the clinical... satisfaction with device” (i.e. prosthesis) than the IC Socket. 2. KEYWORDS: Prosthetic Socket, Artificial Limbs, Prosthesis, Transfemoral Amputee, Gait...FlexSIV Socket will result in better quality of life and “ satisfaction with device” (i.e. prosthesis) than the IC socket. Accomplishments under

  17. The possible nature of socket stars in H II regions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castelaz, M.W.

    1990-01-01

    Close inspection of faint stars (V of about 14 mag) in H II regions show that they appear to be surrounded by circumstellar envelopes of about 10 arcsecs in diameter (as reported by Feibelman in 1989). The present premise is that the sockets are envelopes of obscuring dust which should emit a measurable amount of infrared radiation based on a simple thermal equilibrium model. A search of literature shows that, of 36 socket stars listed by Feibelman, 17 have been measured in the infrared. Of the 17, 14 show excess IR emission. This is very strong evidence that the socketmore » stars are really stars with circumstellar envelopes. Socket stars may be a new type of astronomical object or well-known astronomical objects in environments or evolutionary states not previously seen. 22 refs.« less

  18. Strength evaluation of socket joints

    NASA Technical Reports Server (NTRS)

    Rash, Larry C.

    1994-01-01

    This report documents the development of a set of equations that can be used to provide a relatively simple solution for identifying the strength of socket joints and for most cases avoid the need of more lengthy analyses. The analytical approach was verified by comparison of the contact load distributions to results obtained from a finite element analysis. The contacting surfaces for the specific joint in this analysis are in the shape of frustrums of a cone and are representative of the tapered surfaces in the socket-type joints used to join segments of model support systems for wind tunnels. The results are in the form of equations that can be used to determine the contact loads and stresses in the joint from the given geometry and externally applied loads. Equations were determined to define the bending moments and stresses along the length of the joints based on strength and materials principles. The results have also been programmed for a personal computer and a copy of the program is included.

  19. Computerized tomography magnified bone windows are superior to standard soft tissue windows for accurate measurement of stone size: an in vitro and clinical study.

    PubMed

    Eisner, Brian H; Kambadakone, Avinash; Monga, Manoj; Anderson, James K; Thoreson, Andrew A; Lee, Hang; Dretler, Stephen P; Sahani, Dushyant V

    2009-04-01

    We determined the most accurate method of measuring urinary stones on computerized tomography. For the in vitro portion of the study 24 calculi, including 12 calcium oxalate monohydrate and 12 uric acid stones, that had been previously collected at our clinic were measured manually with hand calipers as the gold standard measurement. The calculi were then embedded into human kidney-sized potatoes and scanned using 64-slice multidetector computerized tomography. Computerized tomography measurements were performed at 4 window settings, including standard soft tissue windows (window width-320 and window length-50), standard bone windows (window width-1120 and window length-300), 5.13x magnified soft tissue windows and 5.13x magnified bone windows. Maximum stone dimensions were recorded. For the in vivo portion of the study 41 patients with distal ureteral stones who underwent noncontrast computerized tomography and subsequently spontaneously passed the stones were analyzed. All analyzed stones were 100% calcium oxalate monohydrate or mixed, calcium based stones. Stones were prospectively collected at the clinic and the largest diameter was measured with digital calipers as the gold standard. This was compared to computerized tomography measurements using 4.0x magnified soft tissue windows and 4.0x magnified bone windows. Statistical comparisons were performed using Pearson's correlation and paired t test. In the in vitro portion of the study the most accurate measurements were obtained using 5.13x magnified bone windows with a mean 0.13 mm difference from caliper measurement (p = 0.6). Measurements performed in the soft tissue window with and without magnification, and in the bone window without magnification were significantly different from hand caliper measurements (mean difference 1.2, 1.9 and 1.4 mm, p = 0.003, <0.001 and 0.0002, respectively). When comparing measurement errors between stones of different composition in vitro, the error for calcium oxalate

  20. Hard tissue alterations after socket preservation with additional buccal overbuilding: a study in the beagle dog.

    PubMed

    Fickl, Stefan; Zuhr, Otto; Wachtel, Hannes; Kebschull, Moritz; Hürzeler, Markus B

    2009-10-01

    The aim of this study was to histometrically assess alterations of the ridge following socket preservation alone and socket preservation with additional buccal overbuilding. In five beagle dogs four extraction sites were randomly subjected to one of the following treatments: Tx 1: The socket was filled with BioOss Collagen and covered with a free gingival graft from the palate. Tx 2: The buccal bone plate was augmented using the GBR-technique, the socket was filled with BioOss Collagen and covered with a free gingival graft. Tx 3: The buccal bone plate was forced into a buccal direction using a manual bone spreader. The socket was filled with BioOss Collagen and covered with a free gingival graft from the palate. Tx 4: The socket was filled with BioOss Collagen and a combined free gingival/connective tissue graft was used to cover the socket and for buccal tissue augmentation. For each experimental site, two histological sections were subjected to histometric analysis and evaluated for (i) vertical bone dimensions and (ii) horizontal bone dimensions. All treatment groups showed horizontal and vertical bone loss. The mean vertical bone loss of the buccal bone plate was significantly lower in Tx 4 than in the other groups, while no statistical significant differences could be detected among the groups in the horizontal dimension. Overbuilding the buccal aspect in combination with socket preservation does not seem to be a suitable technique to compensate for the alterations after tooth extraction.

  1. Effect of alignment changes on sagittal and coronal socket reaction moment interactions in transtibial prostheses.

    PubMed

    Kobayashi, Toshiki; Orendurff, Michael S; Zhang, Ming; Boone, David A

    2013-04-26

    Alignment is important for comfortable and stable gait of lower-limb prosthesis users. The magnitude of socket reaction moments in the multiple planes acting simultaneously upon the residual limb may be related to perception of comfort in individuals using prostheses through socket interface pressures. The aim of this study was to investigate the effect of prosthetic alignment changes on sagittal and coronal socket reaction moment interactions (moment-moment curves) and to characterize the curves in 11 individuals with transtibial amputation using novel moment-moment interaction parameters measured by plotting sagittal socket reaction moments versus coronal ones under various alignment conditions. A custom instrumented prosthesis alignment component was used to measure socket reaction moments during walking. Prosthetic alignment was tuned to a nominally aligned condition by a prosthetist, and from this position, angular (3° and 6° of flexion, extension, abduction or adduction of the socket) and translational (5mm and 10mm of anterior, posterior, medial or lateral translation of the socket) alignment changes were performed in either the sagittal or the coronal plane in a randomized manner. A total of 17 alignment conditions were tested. Coronal angulation and translation alignment changes demonstrated similar consistent changes in the moment-moment curves. Sagittal alignment changes demonstrated more complex changes compared to the coronal alignment changes. Effect of sagittal angulations and translations on the moment-moment curves was different during 2nd rocker (mid-stance) with extension malalignment appearing to cause medio-lateral instability. Presentation of coronal and sagittal socket reaction moment interactions may provide useful visual information for prosthetists to understand the biomechanical effects of malalignment of transtibial prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. The reconstruction of a contracted eye socket using a post-auricular full-thickness skin graft.

    PubMed

    Wei, Yi Hsuan; Liao, Shu Lang

    2014-05-01

    To report the efficacy of a full-thickness skin graft (FTSG) for the reconstruction of a contracted eye socket. A retrospective, non-comparative, interventional case series. This was a retrospective review of patients with a contracted eye socket who underwent socket reconstruction using a post-auricular FTSG from 2001 to 2011 at the National Taiwan University Hospital. The postoperative results including prosthetic fitting, the cosmetic result, and eyelid function were assessed. There were 11 male and 15 female patients, with a mean age of 52.3 ± 15.6 years (range 21 to 76). The duration of the socket contracture varied from three months to three years (average 7.4 ± 8.1 months). The severity of the socket contracture ranged from grade 2 to grade 4, based on Tawfik's classification. The mean follow-up time was 35.7 ± 9.6 months. After socket reconstruction, using a post-auricular FTSG, 96% of the cases (25 of 26) demonstrated a successful prosthetic fitting and a satisfactory cosmetic outcome. Both good eyelid function and a stable fornix depth were maintained during the follow-up time. One case received a second socket reconstruction three months after the first operation, using a FTSG, because of an inadequate lateral fornix. The final result was satisfactory. There were no serious complications, but a granuloma formed in one case, and there was prolonged discharge in one case. The reconstruction of a contracted eye socket using a post-auricular FTSG is an effective method with a high success rate, which causes less discomfort to donor sites and results in few complications.

  3. Subclassification and Clinical Management of Extraction Sockets with Labial Dentoalveolar Dehiscence Defects.

    PubMed

    Chu, Stephen J; Sarnachiaro, Guido O; Hochman, Mark N; Tarnow, Dennis P

    2015-01-01

    Immediate implant therapy involving implants placed into intact Type 1 extraction sockets has become a consistent clinical technique. The classification of Type 2 extraction sockets, where the mucosal tissues are present but there is a midfacial osseous dehiscence defect, has been described according to the extent of the buccal bone plate absence. The literature has offered different techniques in the treatment of Type 2 sockets; however, the extent of the defect has never been defined or delineated. In this article, the authors describe a subclassification of Type 2 sockets: Type 2A presents with a dehiscence defect roughly 5 mm to 6 mm from the free gingival margin (FGM) involving the coronal one-third of the labial bone plate; Type 2B presents with a dehiscence defect involving the middle one-third of the labial plate, approximately 7 mm to 9 mm from the FGM; and in Type 2C the dehiscence defect involves the apical one-third of the labial osseous plate roughly 10 mm or greater from the FGM. The authors also offer a protocol and technique employing immediate implant placement, guided bone regeneration, and bone graft containment with a custom two-piece healing abutment that can lead to consistent and satisfactory clinical outcomes in low-smile-line patients. The treatment protocol and sequence is outlined in a clinical case presentation involving a Type 2B socket.

  4. Scale up of large ALON® and spinel windows

    NASA Astrophysics Data System (ADS)

    Goldman, Lee M.; Kashalikar, Uday; Ramisetty, Mohan; Jha, Santosh; Sastri, Suri

    2017-05-01

    Aluminum Oxynitride (ALON® Transparent Ceramic) and Magnesia Aluminate Spinel (Spinel) combine broadband transparency with excellent mechanical properties. Their cubic structure means that they are transparent in their polycrystalline form, allowing them to be manufactured by conventional powder processing techniques. Surmet has scaled up its ALON® production capability to produce and deliver windows as large as 4.4 sq ft. We have also produced our first 6 sq ft window. We are in the process of producing 7 sq ft ALON® window blanks for armor applications; and scale up to even larger, high optical quality blanks for Recce window applications is underway. Surmet also produces spinel for customers that require superior transmission at the longer wavelengths in the mid wave infra-red (MWIR). Spinel windows have been limited to smaller sizes than have been achieved with ALON. To date the largest spinel window produced is 11x18-in, and windows 14x20-in size are currently in process. Surmet is now scaling up its spinel processing capability to produce high quality window blanks as large as 19x27-in for sensor applications.

  5. Langley Research Center Standard for the Evaluation of Socket Welds

    NASA Technical Reports Server (NTRS)

    Berry, R. F., Jr.

    1985-01-01

    A specification utilized for the nondestructive evaluation of socket type pipe joints at Langley Research Center (LaRC) is discussed. The scope of hardware shall include, but is not limited to, all common pipe fittings: tees, elbows, couplings, caps, and so forth, socket type flanges, unions, and valves. In addition, the exterior weld of slip on flanges shall be inspected using this specification. At the discretion of the design engineer, standard practice engineer, Fracture Mechanics Engineering Section, Pressure Systems Committee, or other authority, four nondestructive evaluation techniques may be utilized exclusively, or in combination, to inspect socket type welds. These techniques are visual, radiographic, magnetic particle, and dye penetrant. Under special circumstances, other techniques (such as eddy current or ultrasonics) may be required and their application shall be guided by the appropriate sections of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (B&PVC).

  6. The Quantum Socket: Wiring for Superconducting Qubits - Part 3

    NASA Astrophysics Data System (ADS)

    Mariantoni, M.; Bejianin, J. H.; McConkey, T. G.; Rinehart, J. R.; Bateman, J. D.; Earnest, C. T.; McRae, C. H.; Rohanizadegan, Y.; Shiri, D.; Penava, B.; Breul, P.; Royak, S.; Zapatka, M.; Fowler, A. G.

    The implementation of a quantum computer requires quantum error correction codes, which allow to correct errors occurring on physical quantum bits (qubits). Ensemble of physical qubits will be grouped to form a logical qubit with a lower error rate. Reaching low error rates will necessitate a large number of physical qubits. Thus, a scalable qubit architecture must be developed. Superconducting qubits have been used to realize error correction. However, a truly scalable qubit architecture has yet to be demonstrated. A critical step towards scalability is the realization of a wiring method that allows to address qubits densely and accurately. A quantum socket that serves this purpose has been designed and tested at microwave frequencies. In this talk, we show results where the socket is used at millikelvin temperatures to measure an on-chip superconducting resonator. The control electronics is another fundamental element for scalability. We will present a proposal based on the quantum socket to interconnect a classical control hardware to a superconducting qubit hardware, where both are operated at millikelvin temperatures.

  7. The Quantum Socket: Wiring for Superconducting Qubits - Part 2

    NASA Astrophysics Data System (ADS)

    Bejanin, J. H.; McConkey, T. G.; Rinehart, J. R.; Bateman, J. D.; Earnest, C. T.; McRae, C. H.; Rohanizadegan, Y.; Shiri, D.; Mariantoni, M.; Penava, B.; Breul, P.; Royak, S.; Zapatka, M.; Fowler, A. G.

    Quantum computing research has reached a level of maturity where quantum error correction (QEC) codes can be executed on linear arrays of superconducting quantum bits (qubits). A truly scalable quantum computing architecture, however, based on practical QEC algorithms, requires nearest neighbor interaction between qubits on a two-dimensional array. Such an arrangement is not possible with techniques that rely on wire bonding. To address this issue, we have developed the quantum socket, a device based on three-dimensional wires that enables the control of superconducting qubits on a two-dimensional grid. In this talk, we present experimental results characterizing this type of wiring. We will show that the quantum socket performs exceptionally well for the transmission and reflection of microwave signals up to 10 GHz, while minimizing crosstalk between adjacent wires. Under realistic conditions, we measured an S21 of -5 dB at 6 GHz and an average crosstalk of -60 dB. We also describe time domain reflectometry results and arbitrary pulse transmission tests, showing that the quantum socket can be used to control superconducting qubits.

  8. Systematic review of effects of current transtibial prosthetic socket designs-Part 1: Qualitative outcomes.

    PubMed

    Safari, Mohammad Reza; Meier, Margrit Regula

    2015-01-01

    This review is an attempt to untangle the complexity of transtibial prosthetic socket fit, determine the most important characteristic for a successful fitting, and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. Further, it is intended to provide directions for future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and used medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design or type of outcome measure. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that incorporated the Downs and Black risk of bias assessment checklist. Results for the qualitative outcomes (n = 19 articles) are synthesized. Total surface bearing sockets lead to greater activity levels and satisfaction in active persons with amputation, those with a traumatic cause of amputation, and younger persons with amputation than patellar tendon bearing sockets. Evidence on vacuum-assisted suction and hydrostatic sockets is inadequate, and further studies are much needed. To improve the scientific basis for prescription, comparison of and correlation between mechanical properties of interface material, socket designs, user characteristics, and outcome measures should be conducted and reported in future studies.

  9. Mucous Membrane Grafting Augmented with Topical Mitomycin C Application in Contracted Socket Repair Surgeries.

    PubMed

    Mandour, Sameh S; Elmazar, Hesham M; Marey, Hatem M; Rahman, Ahmed K Abdel; Sakr, Rokia A

    2016-12-01

    To evaluate the use of intraoperative topical application of mitomycin C (MMC) for managing cases of recurrent socket contraction. A prospective comparative randomized study was carried out on 40 patients suffering from contracted sockets. They were randomly enrolled into 2 groups. Group A included 20 patients who had a surgery to treat contracted socket without augmentation with MMC. Group B patients had an MMC-augmented repair for the contracted socket. Patients were followed up over a period of 12 months for changes in inferior fornix (IF) depth and ability to retain the ocular prosthesis. At the end of the follow-up period, postoperative IF depth was significantly deeper in group B (with MMC) than in group A (without MMC). As well, 75% of the patients in group B could maintain the prosthetic eye shell, whereas only 35% of group A could maintain the prosthesis. This study shows that using intraoperative MMC (0.2 mg/mL) in contracted socket reconstruction plays a significant role in maintaining prosthetic eye. To the best of our knowledge, this study is the first to use MMC on a relatively large scale of patients with contracted socket. However, the follow-up period was relatively short and further work is required to verify the effect of MMC on a longer follow-up period.

  10. 8-year survivorship analysis and subjective results of 687 primary Balgrist hip sockets.

    PubMed

    Echtler, B; Jacob, H A; Houweling, M; Hersche, O

    1999-09-01

    The Balgrist hip socket consists of an outer split ring in the form of a truncated cone, made of titanium, which is expanded by a tapered HDPE insert during implantation, thus ensuring firm primary press-fit and the possibility of retightening in the postoperative remodelling phase. Between November 1987 and October 1996, 687 primary Balgrist hip sockets were implanted in 555 patients. Five hundred and thirty-seven patients were investigated. Of these patients, 71.1% never had pain in the operated hip, 88.1% had no problems putting on their shoes, 76.2% were able to walk one or more hours. Furthermore, 91.7% are very or mostly content with the postoperative result. Nineteen hip sockets had to be revised until April 1997. With a 92.1% Kaplan-Meier survivorship rate after 8 years the Balgrist hip socket ranks among the most successful noncemented acetabular components.

  11. Secure UNIX socket-based controlling system for high-throughput protein crystallography experiments.

    PubMed

    Gaponov, Yurii; Igarashi, Noriyuki; Hiraki, Masahiko; Sasajima, Kumiko; Matsugaki, Naohiro; Suzuki, Mamoru; Kosuge, Takashi; Wakatsuki, Soichi

    2004-01-01

    A control system for high-throughput protein crystallography experiments has been developed based on a multilevel secure (SSL v2/v3) UNIX socket under the Linux operating system. Main features of protein crystallography experiments (purification, crystallization, loop preparation, data collecting, data processing) are dealt with by the software. All information necessary to perform protein crystallography experiments is stored (except raw X-ray data, that are stored in Network File Server) in a relational database (MySQL). The system consists of several servers and clients. TCP/IP secure UNIX sockets with four predefined behaviors [(a) listening to a request followed by a reply, (b) sending a request and waiting for a reply, (c) listening to a broadcast message, and (d) sending a broadcast message] support communications between all servers and clients allowing one to control experiments, view data, edit experimental conditions and perform data processing remotely. The usage of the interface software is well suited for developing well organized control software with a hierarchical structure of different software units (Gaponov et al., 1998), which will pass and receive different types of information. All communication is divided into two parts: low and top levels. Large and complicated control tasks are split into several smaller ones, which can be processed by control clients independently. For communicating with experimental equipment (beamline optical elements, robots, and specialized experimental equipment etc.), the STARS server, developed at the Photon Factory, is used (Kosuge et al., 2002). The STARS server allows any application with an open socket to be connected with any other clients that control experimental equipment. Majority of the source code is written in C/C++. GUI modules of the system were built mainly using Glade user interface builder for GTK+ and Gnome under Red Hat Linux 7.1 operating system.

  12. Bone tissue formation in extraction sockets from sites with advanced periodontal disease: a histomorphometric study in humans.

    PubMed

    Ahn, Jae-Jin; Shin, Hong-In

    2008-01-01

    To investigate postextraction bone formation over time in both diseased and healthy sockets. Core specimens of healing tissues following tooth extraction were obtained at the time of implant placement in patients treated between October 2005 and December 2007. A disease group and a control group were classified according to socket examination at the time of extraction. The biopsy specimens were analyzed histomorphometrically to measure the dimensional changes among 3 tissue types: epithelial layer, connective tissue area, and new bone tissue area. Fifty-five specimens from sites of previously advanced periodontal disease from 45 patients were included in the disease group. Another 12 specimens of previously healthy extraction sockets were collected from 12 different patients as a control. The postextraction period of the disease group varied from 2 to 42 weeks. In the disease group, connective tissue occupied most of the socket during the first 4 weeks. New bone area progressively replaced the connective tissue area after the first 4 weeks. The area proportion of new bone tissue exceeded that of connective tissue by 14 weeks. After 20 weeks, most extraction sockets in the disease group demonstrated continuous new bone formation. The control group exhibited almost complete socket healing after 10 weeks, with no more new bone formation after 20 weeks. Osseous regeneration in the diseased sockets developed more slowly than in the disease-free sockets. After 16 weeks, new bone area exceeded 50% of the total newly regenerated tissue in the sockets with severe periodontal destruction. In the control group, after 8 weeks, new bone area exceeded 50% of the total tissue.

  13. Scintigraphic evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin.

    PubMed

    Gürbüzer, Bahadir; Pikdöken, Levent; Tunali, Mustafa; Urhan, Muammer; Küçükodaci, Zafer; Ercan, Feriha

    2010-05-01

    To evaluate the effect of platelet-rich fibrin (PRF) on the early bone healing process with bone scintigraphy based on technetium-99m methylene diphosphonate uptake in third molar extraction sockets. Fourteen patients with bilaterally soft tissue impacted third mandibular molars were included in the study. The right and left impacted third molars were surgically extracted in the same session. PRF was randomly administered into one of the extraction sockets, whereas the contralateral sockets were left without treatment. Four weeks after surgery, scintigrams were obtained to evaluate scintigraphic differences between PRF-treated and non-PRF-treated sockets. After completion of the clinical study, PRF samples were evaluated by light and scanning electron microscopy. The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 4 weeks postoperatively (P > .05). Abundant fibrin and inflammatory cells were observed by light microscopic examination of PRF samples. Scanning electron microscopic analysis of PRF revealed the existence of platelet aggregates in a fibrin network and crystalline particles on the outer surface of PRF. PRF might not lead to enhanced bone healing in soft tissue impacted mandibular third molar extraction sockets 4 weeks after surgery. PRF exhibits the potential characteristics of an autologous fibrin matrix. However, whether the presence of crystal-like particles on the outer surface of PRF alters bone healing should be investigated further. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Efficacy of different methods used for dry socket management: A systematic review.

    PubMed

    Taberner-Vallverdú, Maria; Nazir, Mariam; Sánchez-Garcés, M Ángeles; Gay-Escoda, Cosme

    2015-09-01

    Dry socket is one of the most common complications occurring after the extraction of a permanent tooth, but in spite of its high incidence there is not an established treatment for this condition. Analyze the efficacy of different methods used in the management of dry socket regarding results of pain's relief and alveolar mucosa healing compared to conventional surgical treatment of curettage and saline irrigation. A Cochrane and PubMed-MEDLINE database search was conducted with the search terms "dry socket", "post-extraction complications", "alvogyl", "alveolar osteitis" and "fibrynolitic alveolitis", individually and next, using the Boolean operator "AND". The inclusion criteria were: clinical studies including at least 10 patients, articles published from 2004 to 2014 written in English. The exclusion criteria were case reports and nonhuman studies. 11 publications were selected from a total of 627. Three of the 11 were excluded after reading the full text. The final review included 8 articles: 3 prospective studies, 2 retrospective studies and 3 clinical trials. They were stratified according to their level of scientific evidence using the SORT criteria (Strenght of Recommendation Taxonomy). All treatments included in the review have the aim to relief patient's pain and promote alveolar mucosa healing in dry socket. Given the heterogeneity of interventions and the type of measurement scale, the results are difficult to compare. Curettage and irrigation should be carried out in dry socket, as well as another therapy such as LLLT, zinc oxide eugenol or plasma rich in growth factors, which are the ones that show better results in pain remission and alveolar mucosa healing. Assessment alveolar bone esposure must be a factor to consider in future research. Taking into account the scientific quality of the articles evaluated, a level B recommendation is given for therapeutic interventions proposed for the treatment of dry socket.

  15. Preliminary evaluation of hermetic JT/LJT/R P connector socket contact design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baca, J.R.F.

    1991-10-01

    This report presents a precursory examination of a number of issues pertaining to socket contacts in hermetic connectors. The principal issues addressed are high-contact resistance and contact chatter (circuit discontinuities). Efforts examining the characteristics of the existing socket contact design, the possibility of connector/contact rework, quick-fix solutions, and contact redesigns are summarized.

  16. Hyaluronic Acid Improves Bone Formation in Extraction Sockets With Chronic Pathology: A Pilot Study in Dogs.

    PubMed

    Kim, Jung-Ju; Song, Hyun Young; Ben Amara, Heithem; Kyung-Rim, Kang; Koo, Ki-Tae

    2016-07-01

    Previous studies on ridge preservation focusing on fresh extraction sockets using graft materials for ridge preservation procedures have reported a delay in the tissue modeling and remodeling phases. The objective of this study is to evaluate the effect of hyaluronic acid (HA) on healing of infected sockets. Six beagle dogs were used in this study. Both mandibular third premolars were hemisected, and the distal roots were extracted. Subsequently, periodontal and endodontic lesions were induced at the remaining mesial root. After communication of the periodontal lesion, an endodontic periapical lesion was observed at 4 months, and the mesial roots of both the right and left sides were extracted. HA was applied into the socket of the test group, and no treatment was administered to the other group (control group). Three months after extraction of the mesial roots, the dogs were sacrificed, and histologic evaluations were performed. The sockets were filled by mineralized bone (47.80% ± 6.60%) and bone marrow (50.47% ± 6.38%) in the control group, whereas corresponding values were 63.29% ± 9.78% and 34.73% ± 8.97% for the test group, respectively. There was a statistically significant difference between the groups. Reversal lines and a copious lineup of osteoblasts were observed in the middle and apical parts of the sockets in the test group. An infected socket shows delayed healing of the socket wound, and HA, because of its osteoinductive, bacteriostatic, and anti-inflammatory properties, may improve bone formation and accelerate wound healing in infected sockets.

  17. Carbon nanotubes functionalized with sodium hyaluronate restore bone repair in diabetic rat sockets.

    PubMed

    Sá, M A; Andrade, V B; Mendes, R M; Caliari, M V; Ladeira, L O; Silva, E E; Silva, G A B; Corrêa-Júnior, J D; Ferreira, A J

    2013-07-01

    We evaluated the effects of sodium hyaluronate (HY) and carbon nanotubes functionalized with HY (HY-CNT) on bone repair in the tooth sockets of diabetic rats. Diabetes was induced by streptozotocin (50 mg kg(-1) i.v.), and the sockets were divided into normal control, diabetic control, diabetic treated with HY (1%), and diabetic treated with HY-CNT (100 μg ml(-1)) groups. The sockets were analyzed according to the percentage of bone formation and the number of cell nuclei. The percentage of bone trabeculae was lower in diabetic control animals (11.16 ± 5.10% vs 41.92 ± 6.34% in normal animals) after 14 days. Treating diabetic animals with HY or HY-CNT significantly increased the percentage of neoformed trabeculae (HY: 29.43 ± 3.29%; HY-CNT: 36.90 ± 3.07%). Moreover, the sockets of diabetic animals had an increased number of cell nuclei and HY or HY-CNT reduced this parameter. Our results indicate that HY and HY-CNT restore bone repair in the tooth sockets of diabetic rats, suggesting that these biomaterials are potential adjuvant therapies for the management of diabetes. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Bone implant sockets made using three different procedures: a stability study in dogs

    PubMed Central

    Campo, Julián

    2012-01-01

    Objective: This study compared the effects of three different methods of preparing bone implant sockets (drilling, osteotomes, and piezoelectric device) on osseointegration using resonance frequency analysis (RFA). Study Design: An experimental prospective study was designed. Material and Methods: Ten adult beagle dogs were studied. After 5 weeks, 23 out of 28 initially placed implants in the iliac crest were evaluated, comparing these three different procedures of bone implant socket. Student’s t-test (paired, two-tailed) was used to reveal differences among the three groups at each time point (SPSS 16.0, IL, USA). Results: After a 5-week healing period, the implants placed in sockets that were made using an osteotome or piezoelectric device were slightly more stable than those made by drilling. Reduced mechanical and heat injury to the bone is beneficial for maintaining and improving stability during the critical early healing period. Conclusion: Using RFA, there was evidence of a slight increase in implant stability in the iliac crest after 5 weeks of healing when the implant socket was made using a piezoelectric device or expansion procedure as compare with the drilling method. Key words:Bone implant sockets, drilling, osteotomes, piezoelectric, resonance frequency analysis, stability. PMID:24558558

  19. Detection of Prosthetic Knee Movement Phases via In-Socket Sensors: A Feasibility Study

    PubMed Central

    El-Sayed, Amr M.; Tan, Kenneth Y. S.; Abu Osman, Noor Azuan

    2015-01-01

    This paper presents an approach of identifying prosthetic knee movements through pattern recognition of mechanical responses at the internal socket's wall. A quadrilateral double socket was custom made and instrumented with two force sensing resistors (FSR) attached to specific anterior and posterior sites of the socket's wall. A second setup was established by attaching three piezoelectric sensors at the anterior distal, anterior proximal, and posterior sites. Gait cycle and locomotion movements such as stair ascent and sit to stand were adopted to characterize the validity of the technique. FSR and piezoelectric outputs were measured with reference to the knee angle during each phase. Piezoelectric sensors could identify the movement of midswing and terminal swing, pre-full standing, pull-up at gait, sit to stand, and stair ascent. In contrast, FSR could estimate the gait cycle stance and swing phases and identify the pre-full standing at sit to stand. FSR showed less variation during sit to stand and stair ascent to sensitively represent the different movement states. The study highlighted the capacity of using in-socket sensors for knee movement identification. In addition, it validated the efficacy of the system and warrants further investigation with more amputee subjects and different sockets types. PMID:25945365

  20. Pressure Bearing Device Affects Extraction Socket Remodeling of Maxillary Anterior Tooth. A Prospective Clinical Trial.

    PubMed

    Jiang, Xi; Zhang, Yu; Chen, Bo; Lin, Ye

    2017-04-01

    Extraction socket remodeling and ridge preservation strategies have been extensively explored. To evaluate the efficacy of applying a micro-titanium stent as a pressure bearing device on extraction socket remodeling of maxillary anterior tooth. Twenty-four patients with a extraction socket of maxillary incisor were treated with spontaneous healing (control group) or by applying a micro-titanium stent as a facial pressure bearing device over the facial bone wall (test group). Two virtual models obtained from cone beam computed tomography data before extraction and 4 months after healing were 3-dimenionally superimposed. Facial bone wall resorption, extraction socket remodeling features and ridge width preservation rate were determined and compared between the groups. Thin facial bone wall resulted in marked resorption in both groups. The greatest palatal shifting distance of facial bone located at the coronal level in the control group, but middle level in the test group. Compared with the original extraction socket, 87.61 ± 5.88% ridge width was preserved in the test group and 55.09 ± 14.46% in the control group. Due to the facial pressure bearing property, the rigid micro-titanium stent might preserve the ridge width and alter the resorption features of extraction socket. © 2016 Wiley Periodicals, Inc.

  1. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2014-10-01

    Award Number: W81XWH-10-1-0744 TITLE: Development of Subischial Prosthetic Sockets with Vacuum...REPORT TYPE Annual 3. DATES COVERED 15 Sep 2013 – 14 Sep 2014 4. TITLE AND SUBTITLE Development of Subischial Prosthetic Sockets with Vacuum...to develop a highly flexible sub-ischial prosthetic socket with assisted-vacuum suspension for highly active persons with transfemoral amputation. The

  2. Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees

    PubMed Central

    Kobayashi, Toshiki; Orendurff, Michael S.; Arabian, Adam K.; Rosenbaum-Chou, Teri G.; Boone, David A.

    2014-01-01

    The alignment of a lower limb prosthesis affects the way load is transferred to the residual limb through the socket, and this load is critically important for the comfort and function of the prosthesis. Both magnitude and duration of the moment are important factors that may affect the residual limb health. Moment impulse is a well-accepted measurement that incorporates both factors via moment–time integrals. The aim of this study was to investigate the effect of alignment changes on the socket reaction moment impulse in transtibial prostheses. Ten amputees with transtibial prostheses participated in this study. The socket reaction moment impulse was measured at a self-selected walking speed using a Smart Pyramid™ in 25 alignment conditions, including a nominal alignment (clinically aligned by a prosthetist), as well as angle malalignments of 2°, 4° and 6° (abduction, adduction, extension and flexion) and translation malalignments of 5 mm, 10 mm and 15 mm (lateral, medial, anterior and posterior). The socket reaction moment impulse of the nominal alignment was compared for each condition. The relationship between the alignment and the socket reaction moment impulse was clearly observed in the coronal angle, coronal translation and sagittal translation alignment changes. However, this relationship was not evident in the sagittal angle alignment changes. The results of this study suggested that the socket reaction moment impulse could potentially serve as a valuable parameter to assist the alignment tuning process for transtibial prostheses. Further study is needed to investigate the influence of the socket reaction moment impulse on the residual limb health. PMID:24612718

  3. Gap junctions are selectively associated with interlocking ball-and-sockets but not protrusions in the lens.

    PubMed

    Biswas, Sondip K; Lee, Jai Eun; Brako, Lawrence; Jiang, Jean X; Lo, Woo-Kuen

    2010-11-09

    Ball-and-sockets and protrusions are specialized interlocking membrane domains between lens fibers of all species studied. Ball-and-sockets and protrusions are similar in their shape, size, and surface morphology, and are traditionally believed to play a key role in maintaining fiber-to-fiber stability. Here, we evaluate the hypothesis that ball-and-sockets and protrusions possess important structural and functional differences during fiber cell differentiation and maturation. Intact lenses of leghorn chickens (E7 days to P62 weeks old) and rhesus monkeys (1.5-20 years old) were studied with SEM, freeze-fracture TEM, freeze-fracture immunogold labeling (FRIL), and filipin cytochemistry for membrane cholesterol detection. SEM showed that ball-and-sockets were distributed along the long and short sides of hexagonal fiber cells, whereas protrusions were located along the cell corners, from superficial to deep cortical regions in both chicken and monkey lenses. Importantly, by freeze-fracture TEM, we discovered the selective association of gap junctions with all ball-and-sockets examined, but not with protrusions, in both species. In the embryonic chicken lens (E18), the abundant distribution of ball-and-socket gap junctions was regularly found in an approximate zone extending at least 300 μm deep from the equatorial surface of the superficial cortical fibers. Many ball-and-socket gap junctions often protruded deeply into neighboring cells. However, in the mature fibers of monkey lenses, several ball-and-sockets exhibited only partial occupancy of gap junctions with disorganized connexons, possibly due to degradation of gap junctions during fiber maturation and aging. FRIL analysis confirmed that both connexin46 (Cx46) and connexin50 (Cx50) antibodies specifically labeled ball-and-socket gap junctions, but not protrusions. Furthermore, filipin cytochemistry revealed that the ball-and-socket gap junctions contained different amounts of cholesterol (i.e., cholesterol

  4. Gap junctions are selectively associated with interlocking ball-and-sockets but not protrusions in the lens

    PubMed Central

    Biswas, Sondip K.; Lee, Jai Eun; Brako, Lawrence; Jiang, Jean X.

    2010-01-01

    Purpose Ball-and-sockets and protrusions are specialized interlocking membrane domains between lens fibers of all species studied. Ball-and-sockets and protrusions are similar in their shape, size, and surface morphology, and are traditionally believed to play a key role in maintaining fiber-to-fiber stability. Here, we evaluate the hypothesis that ball-and-sockets and protrusions possess important structural and functional differences during fiber cell differentiation and maturation. Methods Intact lenses of leghorn chickens (E7 days to P62 weeks old) and rhesus monkeys (1.5–20 years old) were studied with SEM, freeze-fracture TEM, freeze-fracture immunogold labeling (FRIL), and filipin cytochemistry for membrane cholesterol detection. Results SEM showed that ball-and-sockets were distributed along the long and short sides of hexagonal fiber cells, whereas protrusions were located along the cell corners, from superficial to deep cortical regions in both chicken and monkey lenses. Importantly, by freeze-fracture TEM, we discovered the selective association of gap junctions with all ball-and-sockets examined, but not with protrusions, in both species. In the embryonic chicken lens (E18), the abundant distribution of ball-and-socket gap junctions was regularly found in an approximate zone extending at least 300 μm deep from the equatorial surface of the superficial cortical fibers. Many ball-and-socket gap junctions often protruded deeply into neighboring cells. However, in the mature fibers of monkey lenses, several ball-and-sockets exhibited only partial occupancy of gap junctions with disorganized connexons, possibly due to degradation of gap junctions during fiber maturation and aging. FRIL analysis confirmed that both connexin46 (Cx46) and connexin50 (Cx50) antibodies specifically labeled ball-and-socket gap junctions, but not protrusions. Furthermore, filipin cytochemistry revealed that the ball-and-socket gap junctions contained different amounts of

  5. Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

    PubMed

    Al-Fakih, Ebrahim A; Abu Osman, Noor Azuan; Mahmad Adikan, Faisal Rafiq

    2016-07-20

    The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.

  6. Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research

    PubMed Central

    Al-Fakih, Ebrahim A.; Abu Osman, Noor Azuan; Mahmad Adikan, Faisal Rafiq

    2016-01-01

    The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket. PMID:27447646

  7. Modified Ball and Socket Coupling

    DOEpatents

    Conley, Jr, W. R.; Pitman, R. W.

    1961-05-23

    A ball and socket coupling arrangement is given in which the male and female members may be engaged or disengaged without visual aid. The female member has an internal spherical seat through which slots are provided to accommodate appropriately arranged and shaped ribs in the male ball member. After engagement of the members, one or both are rotated to lock them together to prevent accidental disengagement.

  8. MODIFIED BALL AND SOCKET COUPLING

    DOEpatents

    Kalen, D.D.

    1961-05-23

    A ball and socket coupling arrangement is described in which the male and female members may be engaged or disengaged without visual aid. The female member has an internal spherical seat through which slots are provided to accommodate appropriately arranged and shaped ribs in the ball member. After engagement of the members, one or both are rotated to lock them together to prevent accidental disengagement. (AEC)

  9. 2-Dimensional changes of the soft tissue profile of augmented and non-augmented human extraction sockets: a randomized pilot study.

    PubMed

    Flügge, Tabea; Nelson, Katja; Nack, Claudia; Stricker, Andres; Nahles, Susanne

    2015-04-01

    This study identified the soft tissue changes of the alveolar ridge at different time points within 12 weeks after tooth extraction with and without socket augmentation. In 38 patients with single tooth extractions, 40 sockets were augmented and 39 extraction sockets were not augmented. At 2, 4, 6, 8 and 12 weeks impressions were taken and casts digitized with a laser scanner. The horizontal and vertical changes were compared between augmented and non-augmented sites. A p-value <0.05 was considered statistically significant. The mean changes of augmented sockets were between 0.4 mm (2 weeks) and 0.8 mm (12 weeks). In non-augmented sockets changes of 0.7 mm (2 weeks) and of 1.0 mm (12 weeks) were demonstrated. The mean values differed significantly between the buccal and oral region (p < 0.01). Overall, there were significant differences of the mean dimensional changes regarding time (p < 0.01) and augmentation (p < 0.01). Augmented sockets showed less resorption within 4 weeks after extraction compared to non-augmented sockets. Non-augmented sockets showed a continuous dimensional loss with a great variation over 12 weeks whereas augmented sockets had the highest degree of resorption between 4 and 6 weeks. At 12 weeks a comparable resorption in augmented and non-augmented sockets was observed. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Compound windows of the Hénon-map

    NASA Astrophysics Data System (ADS)

    Lorenz, Edward N.

    2008-08-01

    For the two-parameter second-order Hénon map, the shapes and locations of the periodic windows-continua of parameter values for which solutions x0,x1,… can be stably periodic, embedded in larger regions where chaotic solutions or solutions of other periods prevail-are found by a random searching procedure and displayed graphically. Many windows have a typical shape, consisting of a central “body” from which four narrow “antennae” extend. Such windows, to be called compound windows, are often arranged in bands, to be called window streets, that are made up largely of small detected but poorly resolved compound windows. For each fundamental subwindow-the portion of a window where a fundamental period prevails-a stability measure U is introduced; where the solution is stable, |U|<1. Curves of constant U are found by numerical integration. Along one line in parameter space the Hénon-map reduces to the one-parameter first-order logistic map, and two antennae from each compound window intersect this line. The curves where U=1 and U=-1 that bound either antenna are close together within these intersections, but, as either curve with U=-1 leaves the line, it diverges from the curve where U=1, crosses the other curve where U=-1, and nears the other curve where U=1, forming another antenna. The region bounded by the numerically determined curves coincides with the subwindow as found by random searching. A fourth-degree equation for an idealized curve of constant U is established. Points in parameter space producing periodic solutions where x0=xm=0, for given values of m, are found to lie on Cantor sets of curves that closely fit the window streets. Points producing solutions where x0=xm=0 and satisfying a third condition, approximating the condition that xn be bounded as n→-∞, lie on curves, to be called street curves of order m, that approximate individual members of the Cantor set and individual window streets. Compound windows of period m+m‧ tend to

  11. Radiation-transparent windows, method for imaging fluid transfers

    DOEpatents

    Shu, Deming [Darien, IL; Wang, Jin [Burr Ridge, IL

    2011-07-26

    A thin, x-ray-transparent window system for environmental chambers involving pneumatic pressures above 40 bar is presented. The window allows for x-ray access to such phenomena as fuel sprays injected into a pressurized chamber that mimics realistic internal combustion engine cylinder operating conditions.

  12. Socket preservation by beta-tri-calcium phosphate with collagen compared to platelet-rich fibrin: A clinico-radiographic study

    PubMed Central

    Das, Swati; Jhingran, Rajesh; Bains, Vivek Kumar; Madan, Rohit; Srivastava, Ruchi; Rizvi, Iram

    2016-01-01

    Objectives: This study was primarily designed to determine the clinico-radiographic efficacy of platelet-rich fibrin (PRF) and beta-tri-calcium phosphate with collagen (β-TCP-Cl) in preserving extraction sockets. Materials and Methods: For Group I (PRF), residual sockets (n = 15) were filled with autologous PRF obtained from patients' blood; and for Group II (β-TCP-Cl), residual sockets (n = 15) were filled with β-TCP-Cl. For the sockets randomly selected for Group II (β-TCP-Cl), the reshaped Resorbable Tissue Replacement cone was inserted into the socket. Results: Clinically, there was a significantly greater decrease in relative socket depth, but apposition in midcrestal height in Group II (β-TCP-Cl) as compared to Group I (PRF), whereas more decrease in buccolingual width of Group I (PRF) than Group II (β-TCP-Cl) after 6 months. Radiographically, the mean difference in socket height, residual ridge, and width (coronal, middle, and apical third of socket) after 6 months was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). The mean density (in Hounsfield Units) at coronal, middle, and apical third of socket was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). There were statistically significant apposition and resorption for Group I (PRF) whereas nonsignificant resorption and significant apposition for Group II (β-TCP-Cl) in buccal and lingual/palatal cortical plate, respectively, at 6 months on computerized tomography scan. Conclusion: The use of either autologous PRF or β-TCP-Cl was effective in socket preservation. Results obtained from PRF were almost similar to β-TCP-Cl; therefore being autologous, nonimmune, cost-effective, easily procurable regenerative biomaterial, PRF proves to be an insight into the future biofuel for regeneration. PMID:27095909

  13. Socket preservation by beta-tri-calcium phosphate with collagen compared to platelet-rich fibrin: A clinico-radiographic study.

    PubMed

    Das, Swati; Jhingran, Rajesh; Bains, Vivek Kumar; Madan, Rohit; Srivastava, Ruchi; Rizvi, Iram

    2016-01-01

    This study was primarily designed to determine the clinico-radiographic efficacy of platelet-rich fibrin (PRF) and beta-tri-calcium phosphate with collagen (β-TCP-Cl) in preserving extraction sockets. For Group I (PRF), residual sockets (n = 15) were filled with autologous PRF obtained from patients' blood; and for Group II (β-TCP-Cl), residual sockets (n = 15) were filled with β-TCP-Cl. For the sockets randomly selected for Group II (β-TCP-Cl), the reshaped Resorbable Tissue Replacement cone was inserted into the socket. Clinically, there was a significantly greater decrease in relative socket depth, but apposition in midcrestal height in Group II (β-TCP-Cl) as compared to Group I (PRF), whereas more decrease in buccolingual width of Group I (PRF) than Group II (β-TCP-Cl) after 6 months. Radiographically, the mean difference in socket height, residual ridge, and width (coronal, middle, and apical third of socket) after 6 months was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). The mean density (in Hounsfield Units) at coronal, middle, and apical third of socket was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). There were statistically significant apposition and resorption for Group I (PRF) whereas nonsignificant resorption and significant apposition for Group II (β-TCP-Cl) in buccal and lingual/palatal cortical plate, respectively, at 6 months on computerized tomography scan. The use of either autologous PRF or β-TCP-Cl was effective in socket preservation. Results obtained from PRF were almost similar to β-TCP-Cl; therefore being autologous, nonimmune, cost-effective, easily procurable regenerative biomaterial, PRF proves to be an insight into the future biofuel for regeneration.

  14. Effect of alignment changes on socket reaction moments during gait in transfemoral and knee-disarticulation prostheses: case series.

    PubMed

    Kobayashi, Toshiki; Orendurff, Michael S; Boone, David A

    2013-09-27

    The alignment of a lower-limb prosthesis is critical to the successful prosthetic fitting and utilization by the wearer. Loads generated by the socket applied to the residual limb while walking are thought to be different in transfemoral and knee-disarticulation prostheses. The aim of this case series was to compare the socket reaction moments between transfemoral and knee-disarticulation prostheses and to investigate the effect of alignment changes on them. Two amputees, one with a transfemoral prosthesis and another with a knee-disarticulation prosthesis, participated in this study. A Smart Pyramid™ was used to measure socket reaction moments while walking under 9 selected alignment conditions; including nominally aligned, angle malalignments of 6° (flexion, extension, abduction and adduction) and translation malalignments of 15 mm (anterior, posterior, medial and lateral) of the socket relative to the foot. This study found that the pattern of the socket reaction moments was similar between transfemoral and knee-disarticulation prostheses. An extension moment in the sagittal plane and a varus moment in the coronal plane were dominant during stance under the nominally aligned condition. This study also demonstrated that alignment changes might have consistent effects on the socket reaction moments in transfemoral and knee-disarticulation prostheses. Extension and posterior translation of the socket resulted in increases in an extension moment, while abduction and lateral translation of the socket resulted in increases in a varus moment. The socket reaction moments may potentially serve as useful biomechanical parameters to evaluate alignment in transfemoral and knee-disarticulation prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. The efficacy of 1% Betadine mouthwash on the incidence of dry socket after mandibular third molar surgery.

    PubMed

    Hasheminia, Dariush; Moaddabi, Amirhossein; Moradi, Saeid; Soltani, Parisa; Moannaei, Mahsa; Issazadeh, Maryam

    2018-05-01

    Dry socket or alveolar osteitis is a delayed healing of alveolar bone after exodontia causing moderate to severe pain 2-4 days after extraction of teeth. Antibacterial agents such as antibiotics and chlorhexidine have been previously proved to prevent or reduce the incidence of dry socket. Betadine is a mixture of iodine and povidone which has bactericidal, antifungal and antiviral effects. The aim of the present study was to evaluate the effect of preoperative povidone iodine 1% mouthwash before surgical extraction of impacted mandibular third molar, however age, gender and oral hygiene were also considered. 189 patients who needed surgical extraction of Pell and Gregory class A and B mandibular third molars were included in this study. The patients who were not willing to participate in the study, took, women who took oral contraceptives or were in the first 22 days of menstrual cycle were excluded. Patients were randomly assigned to control or test group. 97 patients in the test group took preoperative povidone iodine 1% mouthwash and 92 patients in the control group didn't take any antibiotic or mouthwash. Patients were examined in days 3 and 7 postoperatively for incidence of alveolar osteitis. Chi-square test didn't show any significant relation between dry socket incidence and gender ( p value: 0.848) and Oral hygiene ( p value: 0.866). However, it revealed a significant relation between age and dry socket incidence ( p value: 0.003) and patients older than 30 were reported to have higher incidence of dry socket. Independent T-Test showed a significant difference between the test and control group in incidence of dry socket ( p value: 0.036). Based on the results of this study povidone iodine 1% mouthwash can decrease dry socket incidence also as the age increases, the incidence of dry socket becomes higher. Key words: Dry socket, impaction, betadine, povidone iodine.

  16. Postextraction Dental Implant in the Aesthetic Zone, Socket Shield Technique Versus Conventional Protocol.

    PubMed

    Bramanti, Ennio; Norcia, Antonio; Cicciù, Marco; Matacena, Giada; Cervino, Gabriele; Troiano, Giuseppe; Zhurakivska, Khrystyna; Laino, Luigi

    2018-06-01

    The aim of this randomized controlled trial was to evaluate the survival rate, the marginal bone level, and the aesthetic outcome; at 3 years' follow-up, of dental implants placed into a high-esthetic aesthetic zone by comparing 2 techniques of postextraction implant with immediate loading: the socket shied technique and the conventional insertion technique.Several clinical studies suggested that the avulsion of a dental element causes dimensional alterations of both soft and hard tissues at the postextractive site. To increase the aesthetic outcomes, the "socket-shield technique" has been proposed. This method involves maintaining the vestibular root portion and immediate insertion of the dental implant in close proximity to the root.Patients enrolled in this study were randomized to receive a postextraction implant in the aesthetic zone, either with the socket shied technique or with the conventional insertion technique. Implant survival, marginal bone level, and the pink aesthetic score were the outcomes evaluated.Implant survival rate was 100% in both the groups at 3 years. Implants inserted with the socket shield technique showed better values of both marginal bone level and pink aesthetic score (P < 0.05).Although such preliminary results need to be further confirmed, the socket shield technique seems to be a safe surgical technique that allows an implant rehabilitation characterized by better aesthetic outcomes.

  17. Approach for gait analysis in persons with limb loss including residuum and prosthesis socket dynamics.

    PubMed

    LaPrè, A K; Price, M A; Wedge, R D; Umberger, B R; Sup, Frank C

    2018-04-01

    Musculoskeletal modeling and marker-based motion capture techniques are commonly used to quantify the motions of body segments, and the forces acting on them during human gait. However, when these techniques are applied to analyze the gait of people with lower limb loss, the clinically relevant interaction between the residual limb and prosthesis socket is typically overlooked. It is known that there is considerable motion and loading at the residuum-socket interface, yet traditional gait analysis techniques do not account for these factors due to the inability to place tracking markers on the residual limb inside of the socket. In the present work, we used a global optimization technique and anatomical constraints to estimate the motion and loading at the residuum-socket interface as part of standard gait analysis procedures. We systematically evaluated a range of parameters related to the residuum-socket interface, such as the number of degrees of freedom, and determined the configuration that yields the best compromise between faithfully tracking experimental marker positions while yielding anatomically realistic residuum-socket kinematics and loads that agree with data from the literature. Application of the present model to gait analysis for people with lower limb loss will deepen our understanding of the biomechanics of walking with a prosthesis, which should facilitate the development of enhanced rehabilitation protocols and improved assistive devices. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Clinical and histologic outcomes of socket grafting after flapless tooth extraction: a systematic review of randomized controlled clinical trials.

    PubMed

    Jambhekar, Shantanu; Kernen, Florian; Bidra, Avinash S

    2015-05-01

    Several biomaterials and techniques have been reported for socket grafting and alveolar ridge preservation. However, the evidence for clinical and histologic outcomes for socket grafting with different types of materials in flapless extraction is not clear. The purpose of this systematic review was to analyze the outcomes of a socket grafting procedure performed with flapless extraction of teeth in order to determine which graft material results in the least loss of socket dimensions, the maximum amount of vital bone, the least remnant graft material, and the least amount of connective tissue after a minimum of 12 weeks of healing. Secondary outcomes, including the predictability of regenerating deficient buccal bone, necessity of barrier membranes, and coverage with autogenous soft tissue graft, were also evaluated. An electronic search for articles in the English-language literature was performed independently by multiple investigators using a systematic search process with the PubMed search engine. After applying predetermined inclusion and exclusion criteria, the final list of randomized controlled clinical trials (RCTs) for flapless extraction and socket grafting was analyzed to derive results for the various objectives of the study. The initial electronic search resulted in 2898 titles. The systematic application of inclusion and exclusion criteria resulted in 32 RCTs studying 1354 sockets, which addressed the clinical and histologic outcomes of flapless extraction with socket grafting and provided dimensional and histologic information at or beyond the 12-week reentry period. From these RCTs, the mean loss of buccolingual width at the ridge crest was lowest for xenografts (1.3 mm), followed by allografts (1.63 mm), alloplasts (2.13 mm), and sockets without any socket grafting (2.79 mm). Only 3 studies reported on loss of width at 3 mm below the ridge crest. The mean loss of buccal wall height from the ridge crest was lowest for xenografts (0.57 mm) and

  19. Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

    PubMed

    Sawkey, D L; Faddegon, B A

    2009-03-01

    Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were removed from the beam path, leaving only the exit window. With the x-ray target and flattener out of the beam, uncertainties in physical characteristics and relative position of the target and flattening filter, and in spot size, did not contribute to uncertainty in the energy. Beam current was lowered to reduce recombination effects. The measured dose distributions were compared with Monte Carlo simulation of the electron beam through the treatment head to extract the electron source characteristics. For the nominal 6 and 18 MV x-ray beams, the energies were 6.51 +/- 0.15 and 13.9 +/- 0.2 MeV, respectively, with the uncertainties resulting from uncertainties in the detector position in the measurement and in the stopping power in the simulations. Gaussian spectral distributions were used, with full widths at half maximum ranging from 20 +/- 4% at 6 MV to 13 +/- 4% at 18 MV required to match the fall-off portion of the percent-depth ionization curve. Profiles at the depth of maximum dose from simulations that used the manufacturer-specified exit window geometry and no beam divergence were 2-3 cm narrower than measured profiles. Two simulation configurations yielding the measured profile width were the manufacturer-specified exit window thickness with electron source divergences of 3.3 degrees at 6 MV and 1.8 degrees at 18 MV and an exit window 40% thicker than the manufacturer's specification with no beam divergence. With the x-ray target in place (and no flattener), comparison of measured to simulated profiles sets upper limits on the electron source divergences of 0.2 degrees at 6 MV and 0.1 degrees at 18 MV. A method of determining source

  20. Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees.

    PubMed

    Kobayashi, Toshiki; Orendurff, Michael S; Arabian, Adam K; Rosenbaum-Chou, Teri G; Boone, David A

    2014-04-11

    The alignment of a lower limb prosthesis affects the way load is transferred to the residual limb through the socket, and this load is critically important for the comfort and function of the prosthesis. Both magnitude and duration of the moment are important factors that may affect the residual limb health. Moment impulse is a well-accepted measurement that incorporates both factors via moment-time integrals. The aim of this study was to investigate the effect of alignment changes on the socket reaction moment impulse in transtibial prostheses. Ten amputees with transtibial prostheses participated in this study. The socket reaction moment impulse was measured at a self-selected walking speed using a Smart Pyramid in 25 alignment conditions, including a nominal alignment (clinically aligned by a prosthetist), as well as angle malalignments of 2°, 4° and 6° (abduction, adduction, extension and flexion) and translation malalignments of 5 mm, 10 mm and 15 mm (lateral, medial, anterior and posterior). The socket reaction moment impulse of the nominal alignment was compared for each condition. The relationship between the alignment and the socket reaction moment impulse was clearly observed in the coronal angle, coronal translation and sagittal translation alignment changes. However, this relationship was not evident in the sagittal angle alignment changes. The results of this study suggested that the socket reaction moment impulse could potentially serve as a valuable parameter to assist the alignment tuning process for transtibial prostheses. Further study is needed to investigate the influence of the socket reaction moment impulse on the residual limb health. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Development of a socket-type rib coaptation device made of poly-L-lactide fibers: feasibility study in a canine model

    PubMed Central

    Komatsu, Teruya; Sakaguchi, Yasuto; Muranishi, Yusuke; Yutaka, Yojiro; Date, Hiroshi; Nakamura, Tatsuo

    2018-01-01

    Background Costal coaptation pins made of poly-L-lactide (PLA) are clinically available for fixing surgically divided ribs. However, the clinical results of such rib fixation have not been completely satisfactory. We aimed to develop a new rib coaptation socket system and explore its clinical applicability. Methods We surgically divided three consecutive ribs of each beagle dog, and rib coaptation sockets were implanted to stabilize each rib. Fifteen 3-dimensional (3D)-printed and 30 PLA fiber knitted sockets were implanted in five and ten dogs, respectively, to stabilize the artificially divided ribs. Mechanical analysis of the sockets and radiographical examination of costal fixation were performed to evaluate the effectiveness of the newly developed socket system for rib stabilization. Results All 15 ribs with 3D-printed sockets had displaced 1 month after the operation. Three ribs in one dog with implanted PLA fiber knitted sockets were displaced radiographically after 1 month, and the grade of displacement remained unchanged after 6 months. The remaining 27 ribs fixed with PLA fiber knitted sockets did not show any displacement. Conclusions The PLA fiber knitted rib coaptation socket system was sufficiently durable for the stabilization of divided ribs with biocompatibility. This promising finding can be applied for clinical stabilization of divided ribs. PMID:29850125

  2. Development of a socket-type rib coaptation device made of poly-L-lactide fibers: feasibility study in a canine model.

    PubMed

    Komatsu, Teruya; Sato, Toshihiko; Sakaguchi, Yasuto; Muranishi, Yusuke; Yutaka, Yojiro; Date, Hiroshi; Nakamura, Tatsuo

    2018-04-01

    Costal coaptation pins made of poly-L-lactide (PLA) are clinically available for fixing surgically divided ribs. However, the clinical results of such rib fixation have not been completely satisfactory. We aimed to develop a new rib coaptation socket system and explore its clinical applicability. We surgically divided three consecutive ribs of each beagle dog, and rib coaptation sockets were implanted to stabilize each rib. Fifteen 3-dimensional (3D)-printed and 30 PLA fiber knitted sockets were implanted in five and ten dogs, respectively, to stabilize the artificially divided ribs. Mechanical analysis of the sockets and radiographical examination of costal fixation were performed to evaluate the effectiveness of the newly developed socket system for rib stabilization. All 15 ribs with 3D-printed sockets had displaced 1 month after the operation. Three ribs in one dog with implanted PLA fiber knitted sockets were displaced radiographically after 1 month, and the grade of displacement remained unchanged after 6 months. The remaining 27 ribs fixed with PLA fiber knitted sockets did not show any displacement. The PLA fiber knitted rib coaptation socket system was sufficiently durable for the stabilization of divided ribs with biocompatibility. This promising finding can be applied for clinical stabilization of divided ribs.

  3. Rigid thin windows for vacuum applications

    DOEpatents

    Meyer, Glenn Allyn; Ciarlo, Dino R.; Myers, Booth Richard; Chen, Hao-Lin; Wakalopulos, George

    1999-01-01

    A thin window that stands off atmospheric pressure is fabricated using photolithographic and wet chemical etching techniques and comprises at least two layers: an etch stop layer and a protective barrier layer. The window structure also comprises a series of support ribs running the width of the window. The windows are typically made of boron-doped silicon and silicon nitride and are useful in instruments such as electron beam guns and x-ray detectors. In an electron beam gun, the window does not impede the electrons and has demonstrated outstanding gun performance and survivability during the gun tube manufacturing process.

  4. Dynamic elasticity measurement for prosthetic socket design.

    PubMed

    Kim, Yujin; Kim, Junghoon; Son, Hyeryon; Choi, Youngjin

    2017-07-01

    The paper proposes a novel apparatus to measure the dynamic elasticity of human limb in order to help the design and fabrication of the personalized prosthetic socket. To take measurements of the dynamic elasticity, the desired force generated as an exponential chirp signal in which the frequency increases and amplitude is maintained according to time progress is applied to human limb and then the skin deformation is recorded, ultimately, to obtain the frequency response of its elasticity. It is referred to as a Dynamic Elasticity Measurement Apparatus (DEMA) in the paper. It has three core components such as linear motor to provide the desired force, loadcell to implement the force feedback control, and potentiometer to record the skin deformation. After measuring the force/deformation and calculating the dynamic elasticity of the limb, it is visualized as 3D color map model of the limb so that the entire dynamic elasticity can be shown at a glance according to the locations and frequencies. For the visualization, the dynamic elasticities measured at specific locations and frequencies are embodied using the color map into 3D limb model acquired by using 3D scanner. To demonstrate the effectiveness, the visualized dynamic elasticities are suggested as outcome of the proposed system, although we do not have any opportunity to apply the proposed system to the amputees. Ultimately, it is expected that the proposed system can be utilized to design and fabricate the personalized prosthetic socket in order for releasing the wearing pain caused by the conventional prosthetic socket.

  5. Evora® chromium-cobalt dual mobility socket: results at a minimum 10 years' follow-up.

    PubMed

    Leclercq, S; Benoit, J Y; de Rosa, J P; Tallier, E; Leteurtre, C; Girardin, P H

    2013-12-01

    The Evora chromium-cobalt alloy dual mobility socket claims to display a large articulation tribology different from that of stainless steel models, limiting the risk of intraprosthetic dislocation and wear. The present study reports a minimum of 10years' follow-up in a multicenter prospective series of 200 sockets previously reported on at 5years. The use of chromium-cobalt in dual mobility sockets provides a low rate of failure at 10years, especially as regards to osteolysis and intraprosthetic dislocation. Two hundred hydroxyapatite-coated molded chromium-cobalt sockets without titanium interface were implanted without cement in 194 patients with a mean age of 70 years (range, 32-91 years). Clinical results were assessed on Postel Merle d'Aubigné and Harris scores, plain radiographs and survival analysis. At a mean 11 years' follow-up (10-13 years), 56 patients had died and 31 were lost to follow-up. Four underwent surgical revision (3 femoral components, and 1 socket for migration at 9 years with complete disappearance of the hydroxyapatite). A total of 109 implants were analyzable in 107 patients with a mean age of 81 years (55-93 years). At follow-up, the mean Harris score was 90 (75-96) and the PMA score 16.3 (14-18). There were no cases of loosening (except for the case reoperated on at 9 years) and no acetabular radiolucency or cysts. There were 2 cases of non-evolutive femoral radiolucency and 10 of femoral granuloma, involving head size > 22 mm (P<0.0001) and a cemented titanium stem (P=0.004) as risk factors. There were no dislocations in the large or small articulation. Ten-year survival was 99% (95% CI: 97.3%-100%) with socket revision as censorship criterion. The absence of dislocation in both small and large articulations confirmed the efficacy of the dual mobility concept and suggested an advantage for chromium-cobalt sockets in reducing the rate of intraprosthetic dislocation and preventing blockage of the large articulation by a better

  6. Orbitocraniofacial gunshot wounds: craniofacial reconstruction and preparation of the anophthalmic socket.

    PubMed

    Lauer, S A; Rizzuto, P R; Goodrich, J; Adamo, A

    1995-01-01

    This article is a retrospective clinical and radiographic analysis of four patients who survived high caliber orbitocraniofacial gunshot injuries. Early multidisciplinary craniofacial reconstruction included repair of comminuted orbital fractures with multiple autogenous bone grafts and/or porous polyethylene implants, enucleation, and insertion of a hollow silicone sphere as an anophthalmic socket implant. Migration of the silicone implant occurred in one case, requiring replacement with an autogenous dermis fat graft. There were no cases of extrusion or infection. Socket motility remained limited in all cases, despite reapposition of the extraocular muscles. In two cases with autogenous bone grafts along the orbital roof, there was no radiographic evidence of graft resorption after three years. Soft tissue volume deficiency and superior sulcus deformity developed in the three cases which were followed for more than six months. Despite these limitations, all four patients are wearing comfortable ocular prostheses. The postoperative results support immediate preparation of the anophthalmic socket after craniofacial reconstruction of these injuries.

  7. Protective Socket For Integrated Circuits

    NASA Technical Reports Server (NTRS)

    Wilkinson, Chris; Henegar, Greg

    1988-01-01

    Socket for intergrated circuits (IC's) protects from excessive voltages and currents or from application of voltages and currents in wrong sequence during insertion or removal. Contains built-in switch that opens as IC removed, disconnecting leads from signals and power. Also protects other components on circuit board from transients produced by insertion and removal of IC. Makes unnecessary to turn off power to entire circuit board so other circuits on board continue to function.

  8. Ultra-high resolution water window x ray microscope optics design and analysis

    NASA Technical Reports Server (NTRS)

    Shealy, David L.; Wang, C.

    1993-01-01

    This project has been focused on the design and analysis of an ultra-high resolution water window soft-x-ray microscope. These activities have been accomplished by completing two tasks contained in the statement of work of this contract. The new results from this work confirm: (1) that in order to achieve resolutions greater than three times the wavelength of the incident radiation, it will be necessary to use spherical mirror surfaces and to use graded multilayer coatings on the secondary in order to accommodate the large variations of the angle of incidence over the secondary when operating the microscope at numerical apertures of 0.35 or greater; (2) that surface contour errors will have a significant effect on the optical performance of the microscope and must be controlled to a peak-to-valley variation of 50-100 A and a frequency of 8 periods over the surface of a mirror; and (3) that tolerance analysis of the spherical Schwarzschild microscope has been shown that the water window operations will require 2-3 times tighter tolerances to achieve a similar performance of operations with 130 A radiation. These results have been included in a manuscript included in the appendix.

  9. The efficacy of 1% Betadine mouthwash on the incidence of dry socket after mandibular third molar surgery

    PubMed Central

    Hasheminia, Dariush; Moaddabi, Amirhossein; Moradi, Saeid; Moannaei, Mahsa; Issazadeh, Maryam

    2018-01-01

    Background Dry socket or alveolar osteitis is a delayed healing of alveolar bone after exodontia causing moderate to severe pain 2-4 days after extraction of teeth. Antibacterial agents such as antibiotics and chlorhexidine have been previously proved to prevent or reduce the incidence of dry socket. Betadine is a mixture of iodine and povidone which has bactericidal, antifungal and antiviral effects. The aim of the present study was to evaluate the effect of preoperative povidone iodine 1% mouthwash before surgical extraction of impacted mandibular third molar, however age, gender and oral hygiene were also considered. Material and Methods 189 patients who needed surgical extraction of Pell and Gregory class A and B mandibular third molars were included in this study. The patients who were not willing to participate in the study, took, women who took oral contraceptives or were in the first 22 days of menstrual cycle were excluded. Patients were randomly assigned to control or test group. 97 patients in the test group took preoperative povidone iodine 1% mouthwash and 92 patients in the control group didn’t take any antibiotic or mouthwash. Patients were examined in days 3 and 7 postoperatively for incidence of alveolar osteitis. Results Chi-square test didn’t show any significant relation between dry socket incidence and gender (p value: 0.848) and Oral hygiene (p value: 0.866). However, it revealed a significant relation between age and dry socket incidence (p value: 0.003) and patients older than 30 were reported to have higher incidence of dry socket. Independent T-Test showed a significant difference between the test and control group in incidence of dry socket (p value: 0.036). Conclusions Based on the results of this study povidone iodine 1% mouthwash can decrease dry socket incidence also as the age increases, the incidence of dry socket becomes higher. Key words:Dry socket, impaction, betadine, povidone iodine. PMID:29849968

  10. Quality assessment of systematic reviews on alveolar socket preservation.

    PubMed

    Moraschini, V; Barboza, E Dos S P

    2016-09-01

    The aim of this overview was to evaluate and compare the quality of systematic reviews, with or without meta-analysis, that have evaluated studies on techniques or biomaterials used for the preservation of alveolar sockets post tooth extraction in humans. An electronic search was conducted without date restrictions using the Medline/PubMed, Cochrane Library, and Web of Science databases up to April 2015. Eligibility criteria included systematic reviews, with or without meta-analysis, focused on the preservation of post-extraction alveolar sockets in humans. Two independent authors assessed the quality of the included reviews using AMSTAR and the checklist proposed by Glenny et al. in 2003. After the selection process, 12 systematic reviews were included. None of these reviews obtained the maximum score using the quality assessment tools implemented, and the results of the analyses were highly variable. A significant statistical correlation was observed between the scores of the two checklists. A wide structural and methodological variability was observed between the systematic reviews published on the preservation of alveolar sockets post tooth extraction. None of the reviews evaluated obtained the maximum score using the two quality assessment tools implemented. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. 30 CFR 56.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Weatherproof lamp sockets. 56.12035 Section 56.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  12. 30 CFR 56.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Weatherproof lamp sockets. 56.12035 Section 56.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  13. 30 CFR 56.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Weatherproof lamp sockets. 56.12035 Section 56.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  14. 30 CFR 56.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Weatherproof lamp sockets. 56.12035 Section 56.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  15. 30 CFR 56.12035 - Weatherproof lamp sockets.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Weatherproof lamp sockets. 56.12035 Section 56.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  16. An Individualized 3-Dimensional Designed and Printed Conformer After Dermis Fat Grafting for Complex Sockets.

    PubMed

    Mourits, Daphne L; Remmers, Jelmer S; Tan, Stevie H; Moll, Annette C; Hartong, Dyonne T

    2018-04-03

    To introduce a novel technique to design individually customized conformers for postenucleation sockets with dermis fat implants. We use a 3-dimensional scan of the frontal face/orbit and eyelid contour to design an individualized conformer. This polymethylmetacrylate printed conformer is adapted to patients' socket, palpebral fissures, horizontal eyelid aperture, curvature of the eyelids, and mean diameter of patients' contralateral eye. Sutures through holes in the inferior part of the conformer and in the extension can be placed to fixate the conformer and anchor fornix deepening sutures. A correct fitting conformer can be printed and attached to the socket and eyelids. The shape of this conformer can be used subsequently postsurgically to design the ocular prosthesis. Presurgical planning is important to anticipate for a functional socket to adequately fit an artificial eye. The presented technique using 3-dimensional imaging, designing, and printing promises to prevent conformer extrusion and forniceal shortening.

  17. Novel 3D Approach to Flare Modeling via Interactive IDL Widget Tools

    NASA Astrophysics Data System (ADS)

    Nita, G. M.; Fleishman, G. D.; Gary, D. E.; Kuznetsov, A.; Kontar, E. P.

    2011-12-01

    Currently, and soon-to-be, available sophisticated 3D models of particle acceleration and transport in solar flares require a new level of user-friendly visualization and analysis tools allowing quick and easy adjustment of the model parameters and computation of realistic radiation patterns (images, spectra, polarization, etc). We report the current state of the art of these tools in development, already proved to be highly efficient for the direct flare modeling. We present an interactive IDL widget application intended to provide a flexible tool that allows the user to generate spatially resolved radio and X-ray spectra. The object-based architecture of this application provides full interaction with imported 3D magnetic field models (e.g., from an extrapolation) that may be embedded in a global coronal model. Various tools provided allow users to explore the magnetic connectivity of the model by generating magnetic field lines originating in user-specified volume positions. Such lines may serve as reference lines for creating magnetic flux tubes, which are further populated with user-defined analytical thermal/non thermal particle distribution models. By default, the application integrates IDL callable DLL and Shared libraries containing fast GS emission codes developed in FORTRAN and C++ and soft and hard X-ray codes developed in IDL. However, the interactive interface allows interchanging these default libraries with any user-defined IDL or external callable codes designed to solve the radiation transfer equation in the same or other wavelength ranges of interest. To illustrate the tool capacity and generality, we present a step-by-step real-time computation of microwave and X-ray images from realistic magnetic structures obtained from a magnetic field extrapolation preceding a real event, and compare them with the actual imaging data obtained by NORH and RHESSI instruments. We discuss further anticipated developments of the tools needed to accommodate

  18. A novel image processing technique for 3D volumetric analysis of severely resorbed alveolar sockets with CBCT.

    PubMed

    Manavella, Valeria; Romano, Federica; Garrone, Federica; Terzini, Mara; Bignardi, Cristina; Aimetti, Mario

    2017-06-01

    The aim of this study was to present and validate a novel procedure for the quantitative volumetric assessment of extraction sockets that combines cone-beam computed tomography (CBCT) and image processing techniques. The CBCT dataset of 9 severely resorbed extraction sockets was analyzed by means of two image processing software, Image J and Mimics, using manual and automated segmentation techniques. They were also applied on 5-mm spherical aluminum markers of known volume and on a polyvinyl chloride model of one alveolar socket scanned with Micro-CT to test the accuracy. Statistical differences in alveolar socket volume were found between the different methods of volumetric analysis (P<0.0001). The automated segmentation using Mimics was the most reliable and accurate method with a relative error of 1.5%, considerably smaller than the error of 7% and of 10% introduced by the manual method using Mimics and by the automated method using ImageJ. The currently proposed automated segmentation protocol for the three-dimensional rendering of alveolar sockets showed more accurate results, excellent inter-observer similarity and increased user friendliness. The clinical application of this method enables a three-dimensional evaluation of extraction socket healing after the reconstructive procedures and during the follow-up visits.

  19. Asymmetry in Femoral Tunnel Socket Length During Anterior Cruciate Ligament Reconstruction With Transportal, Outside-In, and Modified Transtibial Techniques.

    PubMed

    Osaki, Kanji; Okazaki, Ken; Matsubara, Hirokazu; Kuwashima, Umito; Murakami, Koji; Iwamoto, Yukihide

    2015-12-01

    To investigate the mismatch between the length at the center and the length on the shortest and longest peripheral sides of the femoral tunnel socket, reamed with the transportal (TP), outside-in (OI), and modified transtibial (TT) techniques, in anterior cruciate ligament (ACL) reconstruction. Femoral tunnel drilling was simulated on 3-dimensional bone models from 40 subjects. The tunnel directions used with the TP, OI, and modified TT techniques were previously described. By use of the resulting angle, a femoral tunnel socket of 9 mm in diameter was drilled from the center of the femoral ACL insertion. The virtual femoral tunnel was extracted, and the length mismatch was measured between the center and the shortest and longest peripheral sides of the tunnel socket. The mean socket length mismatch between the center and the shortest peripheral part of the femoral tunnel socket was 4.2 ± 0.9 mm with the TP technique, 5.2 ± 1.3 mm with the OI technique, and 3.2 ± 0.8 mm with the modified TT technique. The mean socket length mismatch between the center and the longest peripheral part of the femoral tunnel socket was 3.5 ± 0.9 mm with the TP technique, 4.8 ± 1.5 mm with the OI technique, and 3.3 ± 1.2 mm with the modified TT technique. The length mismatch was significantly higher when the tunnel socket was created by the OI technique (P < .01). A length mismatch with the tunnel socket exists after reaming with either the TP, OI, or modified TT technique. In particular, there was a significant increase in length mismatch when the tunnel socket was created by the OI technique, and the length mismatch would easily become greater than 5 mm. The surgeon should recognize this mismatch when it is created and measure the femoral tunnel socket. In anatomic ACL reconstruction, a mismatch between the length at the center and the length at periphery of the femoral tunnel socket occurs, and this is increased particularly when using the OI technique. The discrepancy

  20. Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function

    DTIC Science & Technology

    2017-10-01

    AWARD NUMBER: W81XWH-16-1-0785 TITLE: Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function...2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function 5a...discomfort. 2. KEYWORDS: Provide a brief list of keywords (limit to 20 words). Prosthesis, prosthesis fit, technology , skin problems, amputee

  1. Changes in PGE2 signaling after submandibulectomy alter post-tooth extraction socket healing.

    PubMed

    Mohn, Claudia Ester; Troncoso, Gastón Rodolfo; Bozzini, Clarisa; Conti, María Inés; Fernandez Solari, Javier; Elverdin, Juan Carlos

    2018-03-10

    Saliva is very important to oral health, and a salivary deficit has been shown to bring serious problems to oral health. There is scant information about the mechanisms through which salivary glands participate in post-tooth extraction socket healing. Therefore, the aim of the present study was to investigate the effect of submandibulectomy (SMx), consisting of the ablation of submandibular and sublingual glands (SMG and SLG, respectively), on PGE 2 signaling and other bone regulatory molecules, such as OPG and RANKL, involved in tooth extraction socket healing. Male Wistar rats, 70 g body weight, were assigned to an experimental (subjected to SMx) or a control group (sham operated). One week later, the animals in both groups underwent bilateral extraction of the first mandibular molars. The effect of SMx on different stages of socket healing after tooth extraction (7, 14, and 30 days) was studied by evaluating some parameters of inflammation, including PGE 2 and its receptors, and of bone metabolism, as well as by performing bone biomechanical studies. SMx increased TNFα and PGE 2 content as well as cyclooxygenase-II (COX-II) expression in tooth socket tissue at almost all the studied time points. SMx also had an effect on mRNA expression of PGE 2 receptors at the different time points, but did not significantly alter osteoprotegerin (OPG) and RANKL mRNA expression at any of the studied time points. In addition, an increase in bone mass density was observed in SMx rats compared with matched controls, and the structural and mechanical bone properties of the mandibular socket bone were also affected by SMx. Our results suggest that the SMG/SLG complex regulates cellular activation and differentiation by modulating the production of molecules intervening in tooth extraction socket repair, including the PGE 2 signaling system, which would therefore account for the higher density and resistance of the newly formed bone in SMx rat. © 2018 by the Wound Healing Society.

  2. Editorial Commentary: The All-Epiphyseal Anterior Cruciate Ligament Distal Femoral Approach: Sockets or Tunnels?

    PubMed

    Cordasco, Frank A

    2018-05-01

    I believe that the distal femoral approach for anterior cruciate ligament reconstruction in the skeletally immature athlete with 3 to 6 years of remaining growth is best performed with an all-inside, all-epiphyseal technique using sockets rather than an outside-in approach creating tunnels. A shorter socket rather than a longer tunnel exposes a smaller surface area of the lateral distal femoral physis to potential compromise and resultant valgus malalignment. In addition, exiting the lateral femoral aspect of the epiphysis with a full-diameter tunnel as compared with a smaller diameter drill hole used to prepare a socket places the posterior articular cartilage, the lateral collateral ligament and anterolateral ligament footprints, and the popliteus tendon insertion at risk. My preference for sockets is also related to my belief that they provide a superior biologic milieu for graft incorporation compared with a full-length tunnel with the attendant violation of the lateral femoral cortex of the epiphysis. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. The benefits of using a vacuum-assisted socket system to improve balance and gait in elderly transtibial amputees.

    PubMed

    Samitier, C Beatriz; Guirao, Lluis; Costea, Maria; Camós, Josep M; Pleguezuelos, Eulogio

    2016-02-01

    Lower limb amputation leads to impaired balance, ambulation, and transfers. Proper fit of the prosthesis is a determining factor for successful ambulation. Vacuum-assisted socket systems extract air from the socket, which decreases pistoning and probability of soft-tissue injuries and increases proprioception and socket comfort. To investigate the effect of vacuum-assisted socket system on transtibial amputees' performance-based and perceived balance, transfers, and gait. Quasi-experimental before-and-after study. Subjects were initially assessed using their prosthesis with the regular socket and re-evaluated 4 weeks after fitting including the vacuum-assisted socket system. We evaluated the mobility grade using Medicare Functional Classification Level, Berg Balance Scale, Four Square Step Test, Timed Up and Go Test, the 6-Min Walk Test, the Locomotor Capabilities Index, Satisfaction with Prosthesis (SAT-PRO questionnaire), and Houghton Scale. A total of 16 unilateral transtibial dysvascular amputees, mean age 65.12 (standard deviation = 10.15) years. Using the vacuum-assisted socket system, the patients significantly improved in balance, gait, and transfers: scores of the Berg Balance Scale increased from 45.75 (standard deviation = 6.91) to 49.06 (standard deviation = 5.62) (p < 0.01), Four Square Step Test decreased from 18.18 (standard deviation = 3.84) s to 14.97 (3.9) s (p < 0.01), Timed Up and Go Test decreased from 14.3 (standard deviation = 3.29) s to 11.56 (2.46) s (p < 0.01). The distance walked in the 6-Min Walk Test increased from 288.53 (standard deviation = 59.57) m to 321.38 (standard deviation = 72.81) m (p < 0.01). Vacuum-assisted socket systems are useful for improving balance, gait, and transfers in over-50-year-old dysvascular transtibial amputees. This study gives more insight into the use of vacuum-assisted socket systems to improve elderly transtibial dysvascular amputees

  4. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2012-10-01

    materials to facilitate dissemination of this technique. 15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted...an appropriate mechanical pump to create suitable vacuum for suspension of the prosthesis ...sockets of highly active prosthesis users

  5. Socket Preservation Using a Biomimetic Nanostructured Matrix and Atraumatic Surgical Extraction Technique.

    PubMed

    Mozzati, Marco; Gallesio, Giorgia; Staiti, Giorgio; Iezzi, Giovanna; Piattelli, Adriano; Mortellaro, Carmen

    2017-06-01

    The aim of the present study was to evaluate the efficacy of biomimetic composite bone substitute composed of equine collagen I and Mg-hydroxyapatite in improving socket preservation after tooth extraction in humans. Thirty-two patients were subjected to a single tooth extraction, performed without elevation of the full-thickness flap. In each patient, socket was grafted with the bone substitute and specimens were retrieved 2 months after surgery and processed for histological observations. The clinical outcome variables were healing index, visual analog score for pain, postsurgery complications, and patient satisfaction evaluated through a questionnaire. No adverse reaction or infection occurred, in which healing index averaged 5.8 (range 4-7). Pain scores were lower. The patients' questionnaire outcomes were unanimously in favor of the test treatment. At low-power magnification, it was possible to see a portion of native bone with small marrow spaces and many areas of bone remodeling. At high-power magnification, it could be observed that small newly formed trabeculae originated from the preexisting bone and bone spicules in the middle of the defect. Grafting the postextraction socket with composite bone substitute may improve the healing process by accelerating socket closure and tissue maturation. Such a product demonstrated excellent biocompatibility as no inflammatory reaction could be detected histologically and was well accepted by patients.

  6. The Capability of Fiber Bragg Grating Sensors to Measure Amputees' Trans-Tibial Stump/Socket Interface Pressures

    PubMed Central

    Al-Fakih, Ebrahim A.; Abu Osman, Noor Azuan; Eshraghi, Arezoo; Adikan, Faisal Rafiq Mahamd

    2013-01-01

    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ∼0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction. PMID:23941909

  7. The capability of fiber Bragg grating sensors to measure amputees' trans-tibial stump/socket interface pressures.

    PubMed

    Al-Fakih, Ebrahim A; Osman, Noor Azuan Abu; Eshraghi, Arezoo; Adikan, Faisal Rafiq Mahamd

    2013-08-12

    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.

  8. Weighted Parzen Windows for Pattern Classification

    DTIC Science & Technology

    1994-05-01

    Nearest-Neighbor Rule The k-Nearest-Neighbor ( kNN ) technique is nonparametric, assuming nothing about the distribution of the data. Stated succinctly...probabilities P(wj I x) from samples." Raudys and Jain [20:255] advance this interpretation by pointing out that the kNN technique can be viewed as the...34Parzen window classifier with a hyper- rectangular window function." As with the Parzen-window technique, the kNN classifier is more accurate as the

  9. Influence of platelet rich fibrin on post-extraction socket healing: A clinical and radiographic study.

    PubMed

    Alzahrani, Ahmed Abdullah; Murriky, Afraa; Shafik, Sami

    2017-10-01

    The aim of this study was to evaluate clinically and radiographically, extraction socket healing using autologous platelet rich fibrin (PRF). Twenty-four subjects needing single tooth simple extractions were selected. Twenty-four extraction sockets were divided into test group (PRF, n = 12) and control group (blood clot, n = 12). PRF was prepared with blood drawn from individuals after extraction using standard technique. PRF was placed in test group sockets followed by pressure application and figure 8 sutures. Sockets in control group were allowed to heal in the presence of blood clot and received a figure 8 suture. Ridge width was assessed using cast analysis with the help of acrylic stent and a pair of calipers. Radiographic analysis of socket surface area was performed using computer graphic software program. The clinical follow up assessments were performed at 1, 4 and 8 weeks. Collected data was assessed using ANOVA and multiple comparisons test. Subjects were aged between 25 and 50 (mean 37.8) years, including 15 females. The mean horizontal ridge width for sockets in the test group were 11.70 ± 2.37 mm, 11.33 ± 2.30 mm and 10.97 ± 2.33 mm at 1, 4 and 8 weeks respectively. Ridge width proportions were significantly higher among test group as compared to control group between baseline to 4 and 8 weeks respectively. The mean radiographic bone fill (RBF) percentage in the test group, was 74.05 ± 1.66%, 81.54 ± 3.33% and 88.81 ± 1.53% at 1, 4 and 8 weeks respectively. The mean RBF was significantly higher in the test group than control group at all time intervals. The study outcomes demonstrate that the use of PRF accelerate socket wound healing after tooth extraction as noticed by increased bone fill and reduced alveolar bone width resorption using clinical and radiographic methods.

  10. Study on torsional fretting wear behavior of a ball-on-socket contact configuration simulating an artificial cervical disk.

    PubMed

    Wang, Song; Wang, Fei; Liao, Zhenhua; Wang, Qingliang; Liu, Yuhong; Liu, Weiqiang

    2015-10-01

    A ball-on-socket contact configuration was designed to simulate an artificial cervical disk in structure. UHMWPE (ultra high molecular weight polyethylene) hot pressed by powders and Ti6Al4V alloy were selected as the material combination of ball and socket. The socket surface was coated by a ~500 nm C-DLC (carbon ion implantation-diamond like carbon) mixed layer to improve its surface nano hardness and wear resistance. The torsional fretting wear behavior of the ball-on-socket model was tested at different angular displacements under 25% bovine serum lubrication with an axial force of 100 N to obtain more realistic results with that in vivo. The fretting running regimes and wear damage characteristics as well as wear mechanisms for both ball and socket were studied based on 2D (two dimension) optical microscope, SEM (scanning electron microscope) and 3D (three dimension) profiles. With the increase of angular displacement amplitude from 1° to 7°, three types of T-θ (Torsional torque-angular displacement amplitude) curves (i.e., linear, elliptical and parallelogram loops) corresponding to running regimes of PSR (partial slip regime), MR (mixed regime) and SR (slip regime) were observed and analyzed. Both the central region and the edge zone of the ball and socket were damaged. The worn surfaces were characterized by wear scratches and wear debris. In addition, more severe wear damage and more wear debris appeared on the central region of the socket at higher angular displacement amplitude. The dominant damage mechanism was a mix of surface scratch, adhesive wear and abrasive wear for the UHMWPE ball while that for the coated socket was abrasive wear by PE particles and some polishing and rolling process on the raised overgrown DLC grains. The frictional kinetic behavior, wear type, damage region and damage mechanism for the ball-on-socket model revealed significant differences with those of a ball-on-flat contact while showing better consistency with that of in

  11. Dynamic eye socket reconstruction after extended total maxillectomy using temporalis transfer.

    PubMed

    Motomura, Hisashi; Hatano, Takaharu; Kobayashi, Rie; Sakahara, Daisuke; Fujii, Naho; Mineo, Mari

    2014-03-01

    The functional and cosmetic results of the reconstructive surgery after extended total maxillectomy greatly depend on the quality of the orbital reconstruction. In order to achieve good orbital reconstruction, we developed the dynamic eye socket reconstruction using temporalis transfer. In this report, I will present the details of the technique, including tips and innovations for dynamic eye socket reconstruction.Two patients (2 males, aged 70 and 72 years old) who underwent extensive resection of midfacial tumours were treated with dynamic eye socket reconstruction using temporalis transfer. The follow up period was 16 and 102 months. No acute complications were observed. The movements of the upper/lower eyelids including crow's feet were observed and a good shape in the reconstructed medial/lateral canthal area was maintained in all patients.This procedure provides both the eyelids with movement and also a good shape in the reconstructed medial/lateral canthal region. Furthermore, it contributes to achieving satisfactory functional and cosmetic results in the orbital reconstruction. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Axial bone-socket displacement for persons with a traumatic transtibial amputation: The effect of elevated vacuum suspension at progressive body-weight loads.

    PubMed

    Darter, Benjamin J; Sinitski, Kirill; Wilken, Jason M

    2016-10-01

    Elevated vacuum suspension systems use a pump to draw air from the socket with the intent of reducing bone-socket motion as compared to passive suction systems. However, it remains unknown if elevated vacuum suspension systems decrease limb displacement uniformly during transitions from unloaded to full-body-weight support. To compare limb-socket motion between elevated vacuum and passive suction suspension sockets using a controlled loading paradigm. Comparative analysis. Persons with transtibial amputation were assessed while wearing either an elevated vacuum or passive suction suspension socket. Digital video fluoroscopy was used to measure axial bone-socket motion while the limb was loaded in 20% body-weight increments. An analysis of variance model was used to compare between suspension types. Total axial displacement (0%-100% body weight) was significantly lower using the elevated vacuum (vacuum: 1.3 cm, passive suction: 1.8 cm; p < 0.0001). Total displacement decreased primarily due to decreased motion during initial loading (0%-20%; p < 0.0001). Other body-weight intervals were not significantly different between systems. Elevated vacuum suspension reduced axial limb-socket motion by maintaining position of the limb within the socket during unloaded conditions. Elevated vacuum provided no meaningful improvement in limb-socket motion past initial loading. Excessive bone-socket motion contributes to poor residual limb health. Our results suggest elevated vacuum suspensions can reduce this axial displacement. Visual assessment of the images suggests that this occurs through the reduction or elimination of the air pocket between the liner and socket wall while the limb is unloaded. © The International Society for Prosthetics and Orthotics 2015.

  13. Marker-based method to measure movement between the residual limb and a transtibial prosthetic socket.

    PubMed

    Childers, Walter Lee; Siebert, Steven

    2016-12-01

    Limb movement between the residuum and socket continues to be an underlying factor in limb health, prosthetic comfort, and gait performance yet techniques to measure this have been underdeveloped. Develop a method to measure motion between the residual limb and a transtibial prosthetic socket. Single subject, repeated measures with mathematical modeling. The gait of a participant with transtibial amputation was recorded using a motion capture system using a marker set that included arrays on the anterior distal tibia and the lateral epicondyle of the femur. The proximal or distal translation, anterior or posterior translation, and angular movements were quantified. A random Monte Carlo simulation based on the precision of the motion capture system and a model of the bone moving under the skin explored the technique's accuracy. Residual limb tissue stiffness was modeled as a linear spring based on data from Papaioannou et al. Residuum movement relative to the socket went through ~30 mm, 18 mm, and 15° range of motion. Root mean squared errors were 5.47 mm, 1.86 mm, and 0.75° when considering the modeled bone-skin movement in the proximal or distal, anterior or posterior, and angular directions, respectively. The measured movement was greater than the root mean squared error, indicating that this method can measure motion between the residuum and socket. The ability to quantify movement between the residual limb and the prosthetic socket will improve prosthetic treatment through the evaluation of different prosthetic suspensions, socket designs, and motor control of the prosthetic interface. © The International Society for Prosthetics and Orthotics 2015.

  14. 19. CUSHMAN DAM SPILLWAY FLASHBOARD SOCKETS. March 1927 Reference ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. CUSHMAN DAM SPILLWAY - FLASHBOARD SOCKETS. March 1927 Reference No. BA-056 - Cushman No. 1 Hydroelectric Power Plant, Spillway, North Fork of Skokomish River, 5 miles West of Hood Canal, Hoodsport, Mason County, WA

  15. Demineralised human dentine matrix stimulates the expression of VEGF and accelerates the bone repair in tooth sockets of rats.

    PubMed

    Reis-Filho, Cláudio R; Silva, Elisângela R; Martins, Adalberto B; Pessoa, Fernanda F; Gomes, Paula V N; de Araújo, Mariana S C; Miziara, Melissa N; Alves, José B

    2012-05-01

    In this study we investigated the possible use of human demineralised dentine matrix (DHDM), obtained from the extracted teeth, as bone graft material and evaluated the expression of vascular endothelial growth factor (VEGF) induced by this material in the healing process of tooth sockets of rats. To evaluate bone regeneration and expression of VEGF induced by DHDM, thirty-two male Wistar rats weighing approximately 200 g were used. After maxillary second molar extraction, the left sockets were filled with DHDM and the right sockets were naturally filled by blood clot (control). The animals were sacrificed at 3, 7, 14 and 21 days after surgery and upper maxillaries were processed for histological, morphometric and immunohistochemical analyses. DHDM was used to evaluate the mechanical effect of bone graft material into sockets. Expression of VEGF was determined by immunohistochemistry in all groups. Our results demonstrated a significant increase in the newly formed bone tissue in sockets of 7, 14 and 21 days and a significant increase in VEGF expression at days 7 and 14 on treated sockets. Our results showed that DHDM increases the expression of VEGF and accelerates the healing process in rats tooth sockets, by stimulating bone deposition and also vessels formation. These results suggest that DHDM has osteoinductive/osteoconductive potential and may represent an efficient grafting material on guided bone regeneration. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. A pressure and shear sensor system for stress measurement at lower limb residuum/socket interface.

    PubMed

    Laszczak, P; McGrath, M; Tang, J; Gao, J; Jiang, L; Bader, D L; Moser, D; Zahedi, S

    2016-07-01

    A sensor system for measurement of pressure and shear at the lower limb residuum/socket interface is described. The system comprises of a flexible sensor unit and a data acquisition unit with wireless data transmission capability. Static and dynamic performance of the sensor system was characterised using a mechanical test machine. The static calibration results suggest that the developed sensor system presents high linearity (linearity error ≤ 3.8%) and resolution (0.9 kPa for pressure and 0.2 kPa for shear). Dynamic characterisation of the sensor system shows hysteresis error of approximately 15% for pressure and 8% for shear. Subsequently, a pilot amputee walking test was conducted. Three sensors were placed at the residuum/socket interface of a knee disarticulation amputee and simultaneous measurements were obtained during pilot amputee walking test. The pressure and shear peak values as well as their temporal profiles are presented and discussed. In particular, peak pressure and shear of approximately 58 kPa and 27 kPa, respectively, were recorded. Their temporal profiles also provide dynamic coupling information at this critical residuum/socket interface. These preliminary amputee test results suggest strong potential of the developed sensor system for exploitation as an assistive technology to facilitate socket design, socket fit and effective monitoring of lower limb residuum health. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Dimensional changes of the ridge contour after socket preservation and buccal overbuilding: an animal study.

    PubMed

    Fickl, Stefan; Schneider, David; Zuhr, Otto; Hinze, Marc; Ender, Andreas; Jung, Ronald E; Hürzeler, Markus B

    2009-05-01

    The aim of the study was to volumetrically assess alterations of the ridge contour after socket preservation and buccal overbuilding. In five beagle dogs, four extraction sites were subjected to one of the following treatments: Tx 1: The socket was filled with BioOss Collagen and covered with a free gingival autograft from the palate (SP). Tx 2: The buccal bone plate was forced into a buccal direction using a manual bone spreader and SP was performed. Tx 3: The buccal bone plate was forced into a buccal direction using a manual bone spreader; SP was performed. Tx 4: The socket was filled with BioOss Collagen and a combined free gingival/connective tissue graft was used to cover the socket and for buccal tissue augmentation. Impressions were obtained at baseline, 2 weeks and 4 months post-operatively. Casts were optically scanned and superimposed in one common coordinate system. Using digital image analysis, the volumetric differences per area among the different treatment time points and among the treatment groups were calculated. Four months after tooth extraction, no statistically significant differences with regard to the buccal volume per area could be assessed among the treatment groups. Overbuilding the buccal aspect in combination with socket preservation is not a suitable technique to compensate for the alterations after tooth extraction.

  18. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2015-10-01

    Tuesday August 18, 2015 sagar Shetty Hello Everyone! Good Morning. I just started working with a patient last week for the NU-FiexSIV socket! I would like...RyanCaldwell Hello Ryan Thank you for the help on my patient with the long residual limb I have another liner question_ I have a 40yo female that...JodiHale Hello Jodi, The liner that I use for the "larger patients" would be the seal-in x from Ossur. This liner can go up to a size 55, and I have

  19. Transtibial Prosthetic Socket Shape in a Developing Country: A study to compare initial outcomes in Pressure Cast hydrostatic and Patella Tendon Bearing designs.

    PubMed

    Laing, Sheridan; Lythgo, Noel; Lavranos, Jim; Lee, Peter Vee Sin

    2017-10-01

    This study compared the physical function and comfort level of patients with unilateral transtibial amputation after being fitted with a hand-cast Patella Tendon Bearing (PTB) socket and a pressure-cast (PCAST) hydrocast socket. The latter technique aims to reduce the skill dependency currently required for socket manufacture and fit. The study was conducted at the Vietnamese Training Centre for Orthopaedic Technologies and involved seventeen Vietnamese participants with unilateral transtibial amputation, all of whom were long term users of prosthetics. All participants were fitted with two sockets manufactured using both hand-cast and PCAST techniques with International Committee of the Red Cross components. Walking tests (timed up and go test and six-minute-walk-test), spatio-temporal gait analyses and subjective comfort assessments were completed after a short acclimatisation period with each socket. The participant-preferred socket was also noted. No significant differences were found for the measures of mobility, functional capacity, spatio-temporal gait parameters, gait symmetry, perceived comfort or participant socket preference. The results show the initial patient outcomes are similar when participants are fitted with a hand-cast PTB socket and a PCAST hydrocast sockets. Future work should confirm these findings in a longer trial. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A pilot trial comparing the tear-out behavior in screw-sockets and cemented polyethylene acetabular components - a cadaveric study.

    PubMed

    Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N

    2016-10-01

    The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes

  1. Clinical and impression cytology findings of amniotic membrane and oral mucosal membrane transplantation for the management of socket contracture.

    PubMed

    Kurtul, Bengi Ece; Erdener, Ugur; Mocan, Mehmet Cem; Irkec, Murat; Orhan, Mehmet

    2014-01-01

    To investigate and compare the cytopathological and clinical effects of amniotic membrane transplantation (AMT) and oral mucosal membrane transplantation (OMMT) in socket contraction. Twelve patients who could not be fitted with ocular prosthesis due to socket contracture were included in this study. Seven patients underwent AMT and 5 patients underwent OMMT. Thirteen patients who had healthy sockets were included as control group. Depth of inferior fornix, degree of inflammation, extent of the socket contracture and socket volume were measured in the preoperative period and at sixth and twelfth weeks postoperatively. Impression cytology of conjunctival fornices and tear transforming growth factor beta-1 (TGFβ1) levels were determined. In the AMT group, socket volume and lower fornix depth values were significantly higher (P=0.030 and P=0.004 respectively) and inflammation levels and impression cytology stages (P=0.037 and P=0.022 respectively) were significantly lower in postoperative period compared to preoperative period. In the OMMT group, no statistical differences were found in terms of clinical parameters, inflammation levels and impression cytology stages of preoperative versus postoperative values. Preoperative tear TGFβ1 levels were higher in AMT and OMMT groups compared to the control group (25.5 ng/mL, 26.3 ng/mL and 21.7 ng/mL respectively). Decreased tear TGFβ1 levels were observed in both the AMT and OMMT groups postoperatively (median decrease value=2.1 ng/mL and 2.7 ng/mL respectively). AMT is associated with postoperative improvement in inferior fornix depth, socket volume, inflammation and impression cytology levels and may be a more proper alternative method than OMMT in the management of socket contracture.

  2. Integration of surface electromyographic sensors with the transfemoral amputee socket: a comparison of four differing configurations.

    PubMed

    Hefferman, Gerald M; Zhang, Fan; Nunnery, Michael J; Huang, He

    2015-04-01

    In recent years, there has been an increased interest in recording high-quality electromyographic signals from within the sockets of lower-limb amputees. However, successful recording presents major challenges to both researchers and clinicians. This article details and compares four prototypical integrated socket-sensor designs used to record electromyographic signals from within the sockets of transfemoral amputees. Four prototypical socket-sensor configurations were constructed and tested on a single transfemoral amputee asked to perform sitting/standing, stair ascent/descent, and level ground walking. The number of large-amplitude motion artifacts generated using each prototype was quantified, the amount of skin irritation documented, and the comfort level of each assembly subjectively assessed by the amputee subject. Of the four configurations tested, the combination of a suction socket with integrated wireless surface electrodes generated the lowest number of large-amplitude motion artifacts, the least visible skin irritation, and was judged to be most comfortable by the amputee subject. The collection of high-quality electromyographic signals from an amputee's residual limb while maximizing patient comfort holds substantial potential to enhance neuromuscular clinical assessment and as a method of intuitive control of powered lower-limb prostheses. © The International Society for Prosthetics and Orthotics 2014.

  3. Ultrasound-guided identification of cardiac imaging windows.

    PubMed

    Liu, Garry; Qi, Xiu-Ling; Robert, Normand; Dick, Alexander J; Wright, Graham A

    2012-06-01

    Currently, the use of cine magnetic resonance imaging (MRI) to identify cardiac quiescent periods relative to the electrocardiogram (ECG) signal is insufficient for producing submillimeter-resolution coronary MR angiography (MRA) images. In this work, the authors perform a time series comparison between tissue Doppler echocardiograms of the interventricular septum (IVS) and concurrent biplane x-ray angiograms. Our results indicate very close agreement between the diastasis gating windows identified by both the IVS and x-ray techniques. Seven cath lab patients undergoing diagnostic angiograms were simultaneously scanned during a breath hold by ultrasound and biplane x-ray for six to eight heartbeats. The heart rate of each patient was stable. Dye was injected into either the left or right-coronary vasculature. The IVS was imaged using color tissue Doppler in an apical four-chamber view. Diastasis was estimated on the IVS velocity curve. On the biplane angiograms, proximal, mid, and distal regions were identified on the coronary artery (CA). Frame by frame correlation was used to derive displacement, and then velocity, for each region. The quiescent periods for a CA and its subsegments were estimated based on velocity. Using Pearson's correlation coefficient and Bland-Altman analysis, the authors compared the start and end times of the diastasis windows as estimated from the IVS and CA velocities. The authors also estimated the vessel blur across the diastasis windows of multiple sequential heartbeats of each patient. In total, 17 heartbeats were analyzed. The range of heart rate observed across patients was 47-79 beats per minute (bpm) with a mean of 57 bpm. Significant correlations (R > 0.99; p < 0.01) were observed between the IVS and x-ray techniques for the identification of the start and end times of diastasis windows. The mean difference in the starting times between IVS and CA quiescent windows was -12.0 ms. The mean difference in end times between IVS and CA

  4. The efficacy of hyaluronic acid in postextraction sockets of impacted third molars: A pilot study.

    PubMed

    Yilmaz, N; Demirtas, N; Kazancioglu, H O; Bayer, S; Acar, A H; Mihmanli, A

    2017-12-01

    This study aims to evaluate the effectiveness of local hyaluronic acid (HA) administration to surgically remove impacted third molar sockets and measure pain, swelling, and trismus. The study included a total of 25 healthy patients aged 18-29 years with asymptomatic bilaterally impacted lower third molars. All cases have been performed under local anesthesia. In the study group, 0.8% HA (Gengigel®) was applied in the postextraction sockets of the right third molars and in the control group nothing was applied to the extraction sockets of the left third molars. Postoperative pain, trismus, and swelling were evaluated on the 1st, 3rd, and 7th postoperative days. No difference was determined between groups in facial swelling and maximum mouth opening. However, the amount of pain significantly reduced in HA groups according to visual analog scale (P = 0.001). The results of this study showed that HA can produce an analgesic action in postextraction sockets after surgical removal of impacted teeth and therefore it has a clinical benefit to reduce usage of nonsteroidal anti-inflammatory drugs after dentoalveolar surgery.

  5. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis.

    PubMed

    Hamada, Yusuke; Prabhu, Srividya; John, Vanchit

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as "erratic healing," may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.

  6. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis

    PubMed Central

    Prabhu, Srividya

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as “erratic healing,” may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications. PMID:27807485

  7. Analysis of socket preservation using polylactide and polyglycolide (PLA-PGA) sponge: a clinical, radiographic, and histologic study.

    PubMed

    Madan, Rohit; Mohan, Ranjana; Bains, Vivek K; Gupta, Vivek; Singh, G P; Madan, Mani

    2014-01-01

    The aim of this study was to evaluate the extraction socket healing and dimensional changes following alveolar ridge preservation using polylactide and polyglycolide (PLA-PGA) sponge. Fifteen patients were selected for alveolar socket preservation immediately following tooth extraction. Monoradicular maxillary and mandibular teeth were evaluated. The selected sockets had intact sockets walls with a minimum of 7 mm of residual alveolar bone height. The test sites were thoroughly debrided and grafted with PLA-PGA sponge, while the control sites underwent natural healing. Computed tomography (CT) measurements were taken at baseline and 6 months. After 6 months of healing, final CT measurements were performed, and trephine core biopsy specimens were obtained for histologic analysis. Implants were placed immediately after biopsy harvesting. All subjects completed the study, and all sites healed without adverse events and allowed for implant placement. The mean difference in socket height, width, and density after 6 months was statistically significantly higher in the test sites compared with control sites. Clinical measurement at the midbuccal site of the alveolar socket showed a mean loss of 2.45 ± 0.67 mm in the control group, compared with a mean gain of 1.28 ± 0.58 mm in the test group. All test sites showed minimal ridge alterations, and statistically significant differences were observed between the test and control sites with respect to bone composition and horizontal and vertical bone loss, indicating that PLA-PGA sponge is suitable for alveolar ridge preservation.

  8. Performance prediction using geostatistics and window reservoir simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fontanilla, J.P.; Al-Khalawi, A.A.; Johnson, S.G.

    1995-11-01

    This paper is the first window model study in the northern area of a large carbonate reservoir in Saudi Arabia. It describes window reservoir simulation with geostatistics to model uneven water encroachment in the southwest producing area of the northern portion of the reservoir. In addition, this paper describes performance predictions that investigate the sweep efficiency of the current peripheral waterflood. A 50 x 50 x 549 (240 m. x 260 m. x 0.15 m. average grid block size) geological model was constructed with geostatistics software. Conditional simulation was used to obtain spatial distributions of porosity and volume of dolomite.more » Core data transforms were used to obtain horizontal and vertical permeability distributions. Simple averaging techniques were used to convert the 549-layer geological model to a 50 x 50 x 10 (240 m. x 260 m. x 8 m. average grid block size) window reservoir simulation model. Flux injectors and flux producers were assigned to the outermost grid blocks. Historical boundary flux rates were obtained from a coarsely-ridded full-field model. Pressure distribution, water cuts, GORs, and recent flowmeter data were history matched. Permeability correction factors and numerous parameter adjustments were required to obtain the final history match. The permeability correction factors were based on pressure transient permeability-thickness analyses. The prediction phase of the study evaluated the effects of infill drilling, the use of artificial lifts, workovers, horizontal wells, producing rate constraints, and tight zone development to formulate depletion strategies for the development of this area. The window model will also be used to investigate day-to-day reservoir management problems in this area.« less

  9. Nanofibers of fullerene C60 through interplay of ball-and-socket supermolecules.

    PubMed

    Hubble, Lee J; Raston, Colin L

    2007-01-01

    Mixing solutions of p-tBu-calix[5]arene and C(60) in toluene results in a 1:1 complex (C(60)) intersection(p-tBu-calix[5]arene), which precipitates as nanofibers. The principle structural unit is based on a host-guest ball-and-socket nanostructure of the two components, with an extended structure comprising zigzag/helical arrays of fullerenes (powder X-ray diffraction data coupled with molecular modeling). Under argon at temperatures above 309 degrees C, the fibers undergo selective volatilization of the calixarenes to afford C(60)-core nanostructures encapsulated in a graphitic material sheath, which exhibits a dramatic increase in surface area. Above 650 degrees C the material exhibits an ohmic conductance response, due to the encapsulation process.

  10. Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results

    PubMed Central

    Sabir, Mohammad

    2015-01-01

    Background The aims and objectives of this study were placement of implants in freshly extracted sockets of anterior teeth and to evaluate the implant stability, peri-implant radiolucency and gingival inflammation around implant over a short period of 30 months. Materials and Methods A total of 12 patients (8 male and 4 female), ranging in the age from 20 to 50 years, from March 2007 to June 2007, were evaluated for immediate implant placement into 22 fresh extraction sockets. Only maxillary and mandibular anterior teeth/roots (central incisors, lateral incisors and canines) were considered for replacement with implants. One piece implant with integrated abutment and integrated surface, non-submerged, threaded and tapered at apical 5 mm, sand-blasted and acid etched surfaced implants (HI-TEC TRX-OP Implants of Life Care Company) were used. Results The mobility was not present in any of the implants at all the follow up visits. There were 2 implants at 6 month, 1 implant at 12 month, 1 implant at 18 month visits, showing peri-implant radiolucency at some sites at bone to implant contact site. Severe gingival inflammation was not observed in any of the implant site. At every follow-up visit, every implant met the criteria of success and none was found to be failed over a 30 months duration i.e. 100% success rate was achieved by implants in immediate extraction socket. Conclusion The success rate of implant survival in this study was found 100%. These implants have fulfilled all the criteria of implant success and based on the defined criteria, the success rate of implants placed in immediate extraction sockets of anterior teeth compared favorably with the conventional implants. The early results of the present study showed that high survival rates with the implants in immediate extraction sockets can be achieved. PMID:26266220

  11. Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results.

    PubMed

    Sabir, Mohammad; Alam, Mohammad Nazish

    2015-06-01

    The aims and objectives of this study were placement of implants in freshly extracted sockets of anterior teeth and to evaluate the implant stability, peri-implant radiolucency and gingival inflammation around implant over a short period of 30 months. A total of 12 patients (8 male and 4 female), ranging in the age from 20 to 50 years, from March 2007 to June 2007, were evaluated for immediate implant placement into 22 fresh extraction sockets. Only maxillary and mandibular anterior teeth/roots (central incisors, lateral incisors and canines) were considered for replacement with implants. One piece implant with integrated abutment and integrated surface, non-submerged, threaded and tapered at apical 5 mm, sand-blasted and acid etched surfaced implants (HI-TEC TRX-OP Implants of Life Care Company) were used. The mobility was not present in any of the implants at all the follow up visits. There were 2 implants at 6 month, 1 implant at 12 month, 1 implant at 18 month visits, showing peri-implant radiolucency at some sites at bone to implant contact site. Severe gingival inflammation was not observed in any of the implant site. At every follow-up visit, every implant met the criteria of success and none was found to be failed over a 30 months duration i.e. 100% success rate was achieved by implants in immediate extraction socket. The success rate of implant survival in this study was found 100%. These implants have fulfilled all the criteria of implant success and based on the defined criteria, the success rate of implants placed in immediate extraction sockets of anterior teeth compared favorably with the conventional implants. The early results of the present study showed that high survival rates with the implants in immediate extraction sockets can be achieved.

  12. High-Reliability Waveguide Vacuum/Pressure Window

    NASA Technical Reports Server (NTRS)

    Britcliffe, Michael J.; Hanson, Theodore R.; Long, Ezra M.; Montanez, Steven

    2013-01-01

    The NASA Deep Space Network (DSN) uses commercial waveguide windows on the output waveguide of Ka-band (32 GHz) low-noise amplifiers. Mechanical failure of these windows resulted in an unacceptable loss in tracking time. To address this issue, a new Ka-band WR-28 waveguide window has been designed, fabricated, and tested. The window uses a slab of low-loss, low-dielectric constant foam that is bonded into a 1/2-wave-thick waveguide/flange. The foam is a commercially available, rigid, closed-cell polymethacrylimide. It has excellent electrical properties with a dielectric constant of 1.04, and a loss tangent of 0.01. It is relatively strong with a tensile strength of 1 MPa. The material is virtually impermeable to helium. The finished window exhibits a leak rate of less than 3x10(exp -3)cu cm/s with helium. The material is also chemically resistant and can be cleaned with acetone. The window is constructed by fabricating a window body by brazing a short length of WR-28 copper waveguide into a standard rectangular flange, and machining the resulting part to a thickness of 4.6 mm. The foam is machined to a rectangular shape with a dimension of 7.06x3.53 mm. The foam is bonded into the body with a two-part epoxy. After curing, the excess glue and foam are knife-trimmed by hand. The finished window has a loss of less than 0.08 dB (2%) and a return loss of greater than 25 dB at 32 GHz. This meets the requirements for the DSN application. The window is usable for most applications over the entire 26-to-40-GHz waveguide band. The window return loss can be tuned to a required frequency by var y in g the thickness of the window slightly. Most standard waveguide windows use a thin membrane of material bonded into a recess in a waveguide flange, or sandwiched between two flanges with a polymer seal. Designs using the recessed window are prone to mechanical failure over time due to constraints on the dimensions of the recess that allow the bond to fail. Designs using the

  13. Understanding Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  14. Interacting with Petabytes of Earth Science Data using Jupyter Notebooks, IPython Widgets and Google Earth Engine

    NASA Astrophysics Data System (ADS)

    Erickson, T. A.; Granger, B.; Grout, J.; Corlay, S.

    2017-12-01

    The volume of Earth science data gathered from satellites, aircraft, drones, and field instruments continues to increase. For many scientific questions in the Earth sciences, managing this large volume of data is a barrier to progress, as it is difficult to explore and analyze large volumes of data using the traditional paradigm of downloading datasets to a local computer for analysis. Furthermore, methods for communicating Earth science algorithms that operate on large datasets in an easily understandable and reproducible way are needed. Here we describe a system for developing, interacting, and sharing well-documented Earth Science algorithms that combines existing software components: Jupyter Notebook: An open-source, web-based environment that supports documents that combine code and computational results with text narrative, mathematics, images, and other media. These notebooks provide an environment for interactive exploration of data and development of well documented algorithms. Jupyter Widgets / ipyleaflet: An architecture for creating interactive user interface controls (such as sliders, text boxes, etc.) in Jupyter Notebooks that communicate with Python code. This architecture includes a default set of UI controls (sliders, dropboxes, etc.) as well as APIs for building custom UI controls. The ipyleaflet project is one example that offers a custom interactive map control that allows a user to display and manipulate geographic data within the Jupyter Notebook. Google Earth Engine: A cloud-based geospatial analysis platform that provides access to petabytes of Earth science data via a Python API. The combination of Jupyter Notebooks, Jupyter Widgets, ipyleaflet, and Google Earth Engine makes it possible to explore and analyze massive Earth science datasets via a web browser, in an environment suitable for interactive exploration, teaching, and sharing. Using these environments can make Earth science analyses easier to understand and reproducible, which may

  15. Development of Sub-Ischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2013-10-01

    15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted suspension 16. SECURITY CLASSIFICATION OF: 17...vacuum for suspension of the prosthesis ...14 Task 6 Determine range of volumes to be evacuated from transfemoral sockets of highly active prosthesis users

  16. Efficacy of different methods used for dry socket prevention and risk factor analysis: A systematic review.

    PubMed

    Taberner-Vallverdú, M; Sánchez-Garcés, M-Á; Gay-Escoda, C

    2017-11-01

    Dry socket is one of the most common complications that develops after the extraction of a permanent tooth, and its prevention is more effective than its treatment. Analyze the efficacy of different methods used in preventing dry socket in order to decrease its incidence after tooth extraction. A Cochrane and PubMed-MEDLINE database search was conducted with the search terms "dry socket", "prevention", "risk factors", "alveolar osteitis" and "fibrynolitic alveolitis", both individually and using the Boolean operator "AND". The inclusion criteria were: clinical studies including at least 30 patients, articles published from 2005 to 2015 and written in English. The exclusion criteria were case reports and nonhuman studies. 30 publications were selected from a total of 250. Six of the 30 were excluded after reading the full text. The final review included 24 articles: 9 prospective studies, 2 retrospective studies and 13 clinical trials. They were stratified according to their level of scientific evidence using SIGN criteria (Scottish Intercollegiate Guidelines Network). All treatments included in the review were aimed at decreasing the incidence of dry socket. Locally administering chlorhexidine or applying platelet-rich plasma reduces the likelihood of developing this complication. Antibiotic prescription does not avoid postoperative complications after lower third molar surgery. With regard to risk factors, all of the articles selected suggest that patient age, history of previous infection and the difficulty of the extraction are the most common predisposing factors for developing dry socket. There is no consensus that smoking, gender or menstrual cycles are risk factors. Taking the scientific quality of the articles evaluated into account, a level B recommendation has been given for the proposed-procedures in the prevention of dry socket.

  17. Sockets Manufactured by CAD/CAM Method Have Positive Effects on the Quality of Life of Patients With Transtibial Amputation.

    PubMed

    Karakoç, Mehmet; Batmaz, İbrahim; Sariyildiz, Mustafa Akif; Yazmalar, Levent; Aydin, Abdülkadir; Em, Serda

    2017-08-01

    Patients with amputation need prosthesis to comfortably move around. One of the most important parts of a good prosthesis is the socket. Currently, the most commonly used method is the traditional socket manufacturing method, which involves manual work; however, computer-aided design/computer-aided manufacturing (CAD/CAM) is also being used in the recent years. The present study aimed to investigate the effects of sockets manufactured by traditional and CAD/CAM method on clinical characteristics and quality of life of patients with transtibial amputation. The study included 72 patients with transtibial amputation using prosthesis, 36 of whom had CAD/CAM prosthetic sockets (group 1) and 36 had traditional prosthetic sockets (group 2). Amputation reason, prosthesis lifetime, walking time and distance with prosthesis, pain-free walking time with prosthesis, production time of the prosthesis, and adaptation time to the prosthesis were questioned. Quality of life was assessed using the 36-item Short Form Health Survey questionnaire and the Trinity Amputation and Prosthesis Experience Scales. Walking time and distance and pain-free walking time with prosthesis were significantly better in group 1 than those in group 2. Furthermore, the prosthesis was applied in a significantly shorter time, and socket adaptation time was significantly shorter in group 1. Except emotional role limitation, all 36-item Short Form Healthy Survey questionnaire parameters were significantly better in group 1 than in group 2. Trinity Amputation and Prosthesis Experience Scales activity limitation scores of group 1 were lower, and Trinity Amputation and Prosthesis Experience Scales satisfaction with the prosthesis scores were higher than those in group 2. Our study demonstrated that the sockets manufactured by CAD/CAM methods yield better outcomes in quality of life of patients with transtibial amputation than the sockets manufactured by the traditional method.

  18. Efficiency enhancement using a Zn1- x Ge x -O thin film as an n-type window layer in Cu2O-based heterojunction solar cells

    NASA Astrophysics Data System (ADS)

    Minami, Tadatsugu; Nishi, Yuki; Miyata, Toshihiro

    2016-05-01

    Efficiency enhancement was achieved in Cu2O-based heterojunction solar cells fabricated with a zinc-germanium-oxide (Zn1- x Ge x -O) thin film as the n-type window layer and a p-type Na-doped Cu2O (Cu2O:Na) sheet prepared by thermally oxidizing Cu sheets. The Ge content (x) dependence of the obtained photovoltaic properties of the heterojunction solar cells is mainly explained by the conduction band discontinuity that results from the electron affinity difference between Zn1- x Ge x -O and Cu2O:Na. The optimal value of x in Zn1- x Ge x -O thin films prepared by pulsed laser deposition was observed to be 0.62. An efficiency of 8.1% was obtained in a MgF2/Al-doped ZnO/Zn0.38Ge0.62-O/Cu2O:Na heterojunction solar cell.

  19. Plug-in connector socket accepts coaxial cable end

    NASA Technical Reports Server (NTRS)

    Mitchell, D.; Van Loon, J.

    1966-01-01

    Connector which includes a spring-loaded contact to receive a protruding center conductor and an internal collet to clamp against a collar attached to a woven outer conductor, is used as a receptacle for the end of a coaxial cable. This plug-in connector socket is used successfully with remote manipulators.

  20. Bone modelling at fresh extraction sockets: immediate implant placement versus spontaneous healing: an experimental study in the beagle dog.

    PubMed

    Vignoletti, Fabio; Discepoli, Nicola; Müller, Anna; de Sanctis, Massimo; Muñoz, Fernando; Sanz, Mariano

    2012-01-01

    The purpose of this investigation is to describe histologically the undisturbed healing of fresh extraction sockets when compared to immediate implant placement. In eight beagle dogs, after extraction of the 3P3 and 4P4, implants were inserted into the distal sockets of the premolars, while the mesial sockets were left to heal spontaneously. Each animal provided four socket sites (control) and four implant sites (test). After 6 weeks, animals were sacrificed and tissue blocks were dissected, prepared for ground sectioning. The relative vertical buccal bone resorption in relation to the lingual bone was similar in both test and control groups. At immediate implant sites, however, the absolute buccal bone loss observed was 2.32 (SD 0.36) mm, what may indicate that while an apical shift of both the buccal and lingual bone crest occurred at the implant sites, this may not happen in naturally healing sockets. The results from this investigation showed that after tooth extraction the buccal socket wall underwent bone resorption at both test and control sites. This resorption appeared to be more pronounced at the implant sites, although the limitations of the histological evaluation method utilized preclude a definite conclusion. © 2011 John Wiley & Sons A/S.

  1. High performance sapphire windows

    NASA Technical Reports Server (NTRS)

    Bates, Stephen C.; Liou, Larry

    1993-01-01

    High-quality, wide-aperture optical access is usually required for the advanced laser diagnostics that can now make a wide variety of non-intrusive measurements of combustion processes. Specially processed and mounted sapphire windows are proposed to provide this optical access to extreme environment. Through surface treatments and proper thermal stress design, single crystal sapphire can be a mechanically equivalent replacement for high strength steel. A prototype sapphire window and mounting system have been developed in a successful NASA SBIR Phase 1 project. A large and reliable increase in sapphire design strength (as much as 10x) has been achieved, and the initial specifications necessary for these gains have been defined. Failure testing of small windows has conclusively demonstrated the increased sapphire strength, indicating that a nearly flawless surface polish is the primary cause of strengthening, while an unusual mounting arrangement also significantly contributes to a larger effective strength. Phase 2 work will complete specification and demonstration of these windows, and will fabricate a set for use at NASA. The enhanced capabilities of these high performance sapphire windows will lead to many diagnostic capabilities not previously possible, as well as new applications for sapphire.

  2. High performance sapphire windows

    NASA Astrophysics Data System (ADS)

    Bates, Stephen C.; Liou, Larry

    1993-02-01

    High-quality, wide-aperture optical access is usually required for the advanced laser diagnostics that can now make a wide variety of non-intrusive measurements of combustion processes. Specially processed and mounted sapphire windows are proposed to provide this optical access to extreme environment. Through surface treatments and proper thermal stress design, single crystal sapphire can be a mechanically equivalent replacement for high strength steel. A prototype sapphire window and mounting system have been developed in a successful NASA SBIR Phase 1 project. A large and reliable increase in sapphire design strength (as much as 10x) has been achieved, and the initial specifications necessary for these gains have been defined. Failure testing of small windows has conclusively demonstrated the increased sapphire strength, indicating that a nearly flawless surface polish is the primary cause of strengthening, while an unusual mounting arrangement also significantly contributes to a larger effective strength. Phase 2 work will complete specification and demonstration of these windows, and will fabricate a set for use at NASA. The enhanced capabilities of these high performance sapphire windows will lead to many diagnostic capabilities not previously possible, as well as new applications for sapphire.

  3. Mouse Driven Window Graphics for Network Teaching.

    ERIC Educational Resources Information Center

    Makinson, G. J.; And Others

    Computer enhanced teaching of computational mathematics on a network system driving graphics terminals is being redeveloped for a mouse-driven, high resolution, windowed environment of a UNIX work station. Preservation of the features of networked access by heterogeneous terminals is provided by the use of the X Window environment. A dmonstrator…

  4. Early inhibitory effects of zoledronic acid in tooth extraction sockets in dogs are negated by recombinant human bone morphogenetic protein.

    PubMed

    Gerard, David A; Carlson, Eric R; Gotcher, Jack E; Pickett, David O

    2014-01-01

    This study was conducted with 2 purposes. The first was to determine the effect of a single dose of zoledronic acid (ZA) on the healing of a tooth extraction socket in dogs. The second was to determine if placement of recombinant human bone morphogenetic protein-2 (rhBMP-2)/absorbable collagen sponge (ACS) - INFUSE, (Medtronic, Memphis, TN) into these extraction sockets would inhibit the inhibition on bone healing and remodeling by ZA. Nine adult female beagle dogs (2 to 3 yr old) were placed into 3 groups of 3 dogs each. Group I received 15 mL of sterile saline intravenously; group II received 2.5 mg of ZA intravenously; and group III received 5 mg of ZA intravenously. Forty-five days after treatment, all dogs underwent extraction of noncontiguous right and left mandibular first molars and second premolars. In group I, the right mandibular extraction sockets had nothing placed in them, whereas the left mandibular sockets had only ACS placed in them. In groups II and III, the right mandibular sockets had rhBMP-2/ACS placed in them, whereas the left mandibular sockets had only ACS placed. All extraction sockets were surgically closed. Tetracycline was given intravenously 5 and 12 days later, and all animals were euthanized 15 days after tooth extraction. The extraction sockets and rib and femur samples were harvested immediately after euthanasia, processed, and studied microscopically. A single dose of ZA significantly inhibited healing and bone remodeling in the area of the tooth extractions. The combination of rhBMP-2/ACS appeared to over-ride some of the bone remodeling inhibition of the ZA and increased bone fill in the extraction sites, and remodeling activity in the area was noted. The effects of rhBMP-2/ACS were confined to the area of the extraction sockets because bone activity at distant sites was not influenced. A single dose of ZA administered intravenously inhibits early healing of tooth extraction sockets and bone remodeling in this animal model. The

  5. Attosecond light sources in the water window

    NASA Astrophysics Data System (ADS)

    Ren, Xiaoming; Li, Jie; Yin, Yanchun; Zhao, Kun; Chew, Andrew; Wang, Yang; Hu, Shuyuan; Cheng, Yan; Cunningham, Eric; Wu, Yi; Chini, Michael; Chang, Zenghu

    2018-02-01

    As a compact and burgeoning alternative to synchrotron radiation and free-electron lasers, high harmonic generation (HHG) has proven its superiority in static and time-resolved extreme ultraviolet spectroscopy for the past two decades and has recently gained many interests and successes in generating soft x-ray emissions covering the biologically important water window spectral region. Unlike synchrotron and free-electron sources, which suffer from relatively long pulse width or large time jitter, soft x-ray sources from HHG could offer attosecond time resolution and be synchronized with their driving field to investigate time-resolved near edge absorption spectroscopy, which could reveal rich structural and dynamical information of the interrogated samples. In this paper, we review recent progresses on generating and characterizing attosecond light sources in the water window region. We show our development of an energetic, two-cycle, carrier-envelope phase stable laser source at 1.7 μm and our achievement in producing a 53 as soft x-ray pulse covering the carbon K-edge in the water window. Such source paves the ways for the next generation x-ray spectroscopy with unprecedented temporal resolution.

  6. Disadvantages and advantages of transtibial technique for creating the anterior cruciate ligament femoral socket.

    PubMed

    Robin, Brett N; Lubowitz, James H

    2014-10-01

    Anterior cruciate ligament (ACL) femoral socket techniques have distinct advantages and disadvantages when considering the following techniques: transtibial, anteromedial portal, outside-in, and outside-in retroconstruction. There is no one perfect technique and we have an incomplete understanding of anatomical, biomechanical, isometry, stability, and clinical outcomes. Our primary focus is transtibial technique for creating the ACL femoral socket. Advantages include less invasive, isometric graft placement, stable Lachman exam, and minimal graft impingement with the tunnel and notch. Disadvantages include nonanatomic vertical graft placement that can cause rotational instability and positive pivot shift, interference screw divergence, graft-tunnel length mismatch, femoral socket constraint, posterior cruciate ligament impingement, and a short, oblique tibial tunnel that may undermine the medial plateau in an attempt to achieve anatomic ACL reconstruction. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet

    PubMed Central

    Kobayashi, Toshiki; Arabian, Adam K.; Orendurff, Michael S.; Rosenbaum-Chou, Teri G.; Boone, David A.

    2014-01-01

    Background Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. Methods A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Findings Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. Interpretation The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. PMID:24315709

  8. Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet.

    PubMed

    Kobayashi, Toshiki; Arabian, Adam K; Orendurff, Michael S; Rosenbaum-Chou, Teri G; Boone, David A

    2014-01-01

    Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Radiographic and Histological Evaluation of the Healing of Extraction Sockets Filled With Bovine-Derived Xenograft: An Experimental Study in Rats.

    PubMed

    Zhou, Fengjuan; Zheng, Xiaofei; Xie, Meng; Mo, Anchun; Wu, Hongkun

    2017-06-01

    To evaluate the microenvironment changes in the sockets substituted with bovine-derived xenografts during the early healing period. After extraction of the right maxillary incisor of Sprague Dawley rats, 48 rats were randomly divided into 2 groups. The extraction sockets of the test group were filled with Bio-Oss, whereas the control group was allowed to heal without intervention. The bone quality of the extraction sockets was observed through micro-CT and immunohistochemistry. Micro-CT scanning showed that the bone mineral density in the test group was significantly higher than that in the control group during the early healing period, whereas immunohistochemistry showed that the bone formation-related factors were significantly different between the test and control groups. The bovine-derived xenografts may interfere with the healing process of the extraction socket in the early healing stage. Bone formation of the extraction socket was delayed after grafting with bone substitute.

  10. 40. DETAIL OF BRIDGE NO. 9 ROCKER BEARING AND SOCKET, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    40. DETAIL OF BRIDGE NO. 9 ROCKER BEARING AND SOCKET, SEPARATED. LOOKING NORTH. - Greenville Yard, Transfer Bridge System, Port of New York/New Jersey, Upper New York Bay, Jersey City, Hudson County, NJ

  11. Application of self-balanced loading test to socketed pile in weak rock

    NASA Astrophysics Data System (ADS)

    Cheng, Ye; Gong, Weiming; Dai, Guoliang; Wu, JingKun

    2008-11-01

    Method of self-balanced loading test differs from the traditional methods of pile test. The key equipment of the test is a cell. The cell specially designed is used to exert load which is placed in pile body. During the test, displacement values of the top plate and the bottom plate of the cell are recorded according to every level of load. So Q-S curves can be obtained. In terms of test results, the bearing capacity of pile can be judged. Equipments of the test are simply and cost of it is low. Under some special conditions, the method will take a great advantage. In Guangxi Province, tertiary mudstone distributes widely which is typical weak rock. It is usually chosen as the bearing stratum of pile foundation. In order to make full use of its high bearing capacity, pile is generally designed as belled pile. Foundations of two high-rise buildings which are close to each other are made up of belled socketed piles in weak rock. To obtain the bearing capacity of the belled socketed pile in weak rock, loading test in situ should be taken since it is not reasonable that experimental compression strength of the mudstone is used for design. The self-balanced loading test was applied to eight piles of two buildings. To get the best test effect, the assembly of cell should be taken different modes in terms of the depth that pile socketed in rock and the dimension of the enlarged toe. The assembly of cells had been taken three modes, and tests were carried on successfully. By the self-balanced loading test, the large bearing capacities of belled socketed piles were obtained. Several key parameters required in design were achieved from the tests. For the data of tests had been analyzed, the bearing performance of pile tip, pile side and whole pile was revealed. It is further realized that the bearing capacity of belled socketed pile in the mudstone will decrease after the mudstone it socketed in has been immerged. Among kinds of mineral ingredient in the mudstone

  12. Persistent socket pain postenucleation and post evisceration: a systematic review.

    PubMed

    Hogeboom, Charlotte S E; Mourits, Daphne L; Ket, Johannes C F; Tan, H Stevie; Hartong, Dyonne T; Moll, Annette C

    2018-04-06

    To investigate causes, diagnostics and treatment modalities for persistent socket pain (PSP) after enucleation and evisceration. A systematic search was undertaken in accordance with the PRISMA Statement, in PubMed, Embase.com and Thomson Reuters/Web of Science. We searched for relevant papers until the 28th of July 2016. Inclusion criteria were (1) patients with a history of enucleation or evisceration, (2) PSP, (3) report of the cause and/or used diagnostics and/or treatment modality, (4) full text in English, Dutch or Spanish language. Excluded were (1) review articles, (2) comments, and publications concerning, (3) nonhumans, (4) exenterated patients, (5) acute postoperative pain, or (6) periorbital pain without pain in the socket. Given the lack of high quality evidence from randomized controlled trials, we examined all available evidence from primary observational studies and assessed quality within this lower level of evidence. A total of 32 studies were included. Causes of PSP found were prosthesis-related (n = 5), dry socket (n = 2), trochleitis (n = 3), compression of the trigeminal nerve (n = 2), implant-related (n = unknown), inflammation (n = 5), surgery-related (n = 4), neuromas (n = 8), malignant tumours (n = 3), psychiatric/psychosocial (n = 2), phantom pain (n = 149), rarer entities (n = 3) or unknown (n = 14). Nonsurgical treatments suffice for conditions as trochleitis, prosthesis-related pain, dry socket and for phantom pain. Other causes of pain may require more invasive treatments such as implant removal. Careful history and examination can give some direction in the diagnostic procedure; however, PSP is probably multifactorial and the specific origin(s) may remain uncertain. Implant replacement can be an effective treatment. Studies to identifiy less invasive procedures are required. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Efficacy of different methods used for dry socket prevention and risk factor analysis: A systematic review

    PubMed Central

    Taberner-Vallverdú, Maria; Sánchez-Garcés, Mª Ángeles

    2017-01-01

    Background Dry socket is one of the most common complications that develops after the extraction of a permanent tooth, and its prevention is more effective than its treatment. Objectives Analyze the efficacy of different methods used in preventing dry socket in order to decrease its incidence after tooth extraction. Material and Methods A Cochrane and PubMed-MEDLINE database search was conducted with the search terms “dry socket”, “prevention”, “risk factors”, “alveolar osteitis” and “fibrynolitic alveolitis”, both individually and using the Boolean operator “AND”. The inclusion criteria were: clinical studies including at least 30 patients, articles published from 2005 to 2015 and written in English. The exclusion criteria were case reports and nonhuman studies. Results 30 publications were selected from a total of 250. Six of the 30 were excluded after reading the full text. The final review included 24 articles: 9 prospective studies, 2 retrospective studies and 13 clinical trials. They were stratified according to their level of scientific evidence using SIGN criteria (Scottish Intercollegiate Guidelines Network). Conclusions All treatments included in the review were aimed at decreasing the incidence of dry socket. Locally administering chlorhexidine or applying platelet-rich plasma reduces the likelihood of developing this complication. Antibiotic prescription does not avoid postoperative complications after lower third molar surgery. With regard to risk factors, all of the articles selected suggest that patient age, history of previous infection and the difficulty of the extraction are the most common predisposing factors for developing dry socket. There is no consensus that smoking, gender or menstrual cycles are risk factors. Taking the scientific quality of the articles evaluated into account, a level B recommendation has been given for the proposed-procedures in the prevention of dry socket. Key words:Dry socket, prevention

  14. Immediate provisionalization of dental implants placed in healed alveolar ridges and extraction sockets: a 5-year prospective evaluation.

    PubMed

    Cooper, Lyndon F; Reside, Glenn J; Raes, Filiep; Garriga, Joan Soliva; Tarrida, Luis Giner; Wiltfang, Jörg; Kern, Matthias; De Bruyn, Hugo

    2014-01-01

    This 5-year prospective multicenter study compared implant survival and success, peri-implant health and soft tissue responses, crestal bone level stability, and complication rates following immediate loading of single OsseoSpeed implants placed in anterior maxillary healed ridges or extraction sockets. Individuals requiring anterior tooth replacement with single implants were treated and immediately provisionalized. Definitive all-ceramic crowns were placed at 12 weeks. Implant survival, bone levels, soft tissue levels, and peri-implant health were monitored for 5 years. One hundred thirteen patients received implants in fresh sockets (55) and healed ridges (58). After 5 years, 45 and 49 patients remained for evaluation, respectively. During the first year, three implants failed in the extraction socket group (94.6% survival) and one implant failed in the healed ridge group (98.3% survival); this difference was not significant. No further implant failures were recorded. After 5 years, the interproximal crestal bone levels were located a mean of 0.43 ± 0.63 mm and 0.38 ± 0.62 mm from the reference points of implants in sockets and healed ridges (not a significant difference). In both groups, papillae increased over time and peri-implant mucosal zenith positions were stable from the time of definitive crown placement in sockets and healed ridges. Compared to flap surgery for implants in healed ridges, flapless surgery resulted in increased peri-implant mucosal tissue dimension (average, 0.78 ± 1.34 mm vs 0.19 ± 0.79 mm). After 5 years, the bone and soft tissue parameters that characterize implant success and contribute to dental implant esthetics were similar following the immediate provisionalization of implants in sockets and healed ridges. The overall tissue responses and reported implant survival support the immediate provisionalization of dental implants in situations involving healed ridges and, under ideal circumstances, extraction sockets.

  15. Windowing technique in FM radar realized by FPGA for better target resolution

    NASA Astrophysics Data System (ADS)

    Ponomaryov, Volodymyr I.; Escamilla-Hernandez, Enrique; Kravchenko, Victor F.

    2006-09-01

    Remote sensing systems, such as SAR usually apply FM signals to resolve nearly placed targets (objects) and improve SNR. Main drawbacks in the pulse compression of FM radar signal that it can add the range side-lobes in reflectivity measurements. Using weighting window processing in time domain it is possible to decrease significantly the side-lobe level (SLL) of output radar signal that permits to resolve small or low power targets those are masked by powerful ones. There are usually used classical windows such as Hamming, Hanning, Blackman-Harris, Kaiser-Bessel, Dolph-Chebyshev, Gauss, etc. in window processing. Additionally to classical ones in here we also use a novel class of windows based on atomic functions (AF) theory. For comparison of simulation and experimental results we applied the standard parameters, such as coefficient of amplification, maximum level of side-lobe, width of main lobe, etc. In this paper we also proposed to implement the compression-windowing model on a hardware level employing Field Programmable Gate Array (FPGA) that offers some benefits like instantaneous implementation, dynamic reconfiguration, design, and field programmability. It has been investigated the pulse compression design on FPGA applying classical and novel window technique to reduce the SLL in absence and presence of noise. The paper presents simulated and experimental examples of detection of small or nearly placed targets in the imaging radar. Paper also presents the experimental hardware results of windowing in FM radar demonstrating resolution of the several targets for classical rectangular, Hamming, Kaiser-Bessel, and some novel ones: Up(x), fup 4(x)•D 3(x), fup 6(x)•G 3(x), etc. It is possible to conclude that windows created on base of the AFs offer better decreasing of the SLL in cases of presence or absence of noise and when we move away of the main lobe in comparison with classical windows.

  16. Design method of large-diameter rock-socketed pile with steel casing

    NASA Astrophysics Data System (ADS)

    Liu, Ming-wei; Fang, Fang; Liang, Yue

    2018-02-01

    There is a lack of the design and calculation method of large-diameter rock-socketed pile with steel casing. Combined with the “twelfth five-year plan” of the National Science & Technology Pillar Program of China about “Key technologies on the ports and wharfs constructions of the mountain canalization channels”, this paper put forward the structured design requirements of concrete, steel bar distribution and steel casing, and a checking calculation method of the bearing capacity of the normal section of the pile and the maximum crack width at the bottom of the steel casing. The design method will have some degree of guiding significance for the design of large-diameter rock-socketed pile with steel casing.

  17. Effects of weld defects at root on rotating bending fatigue strength of small diameter socket welded pipe joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higuchi, Makoto; Nakagawa, Akira; Chujo, Noriyuki

    1996-12-01

    Rotating bending fatigue tests were conducted on socket welded joints of a nominal diameter 20 mm, and effects of root defect and other various factors, including post-weld heat treatment (PWHT), pipe wall thickness, and socket wall thickness, were investigated. The socket joints exhibited, in the rotating bending fatigue mode, fatigue strengths that were markedly lower than the same 20 mm diameter joints in four-point bending fatigue. Also, where the latter specimens failed always at the toe, root-failures occurred in rotating bending fatigue. When PWHT`d, however, the fatigue strength showed a remarkable improvement, while the failure site reverted to toe. Thickermore » pipe walls and socket walls gave rise to higher fatigue strength. A formula relating the size of root defects to the fatigue strength reduction has been proposed.« less

  18. Biological effects of compressive forces exerted on particulate bone grafts during socket preservation: animal study.

    PubMed

    Delgado-Ruiz, Rafael; Romanos, Georgios E; Alexandre Gerhke, Sergio; Gomez-Moreno, Gerardo; Maté-Sánchez de Val, José Eduardo; Calvo-Guirado, José Luis

    2016-08-02

    To compare different compressive forces exerted on a particulate graft material during socket preservation and their effects on bone regeneration. Six male dogs were used. The second, third, and fourth premolars, and the first molar were extracted bilaterally at the lower jaws. A particulate synthetic biphasic grafting material (60% HA and 40% β-tricalcium phosphate) was used. Three different standardized compressive forces were applied randomly during the socket preservation. The sample was divided into four experimental groups Test A (10 g), Test B (50 g), Test C (200 g), and Control (empty sockets). Collagen membranes were placed, and primary closure was obtained. Two months after the surgery the animals were sacrificed, and histomorphometric analysis of non-decalcified samples was performed at the coronal, middle, and apical thirds. Grafted sockets resulted in higher bony contour (3 ± 0.43 mm 2 ; P < 0.05). The particles penetrated up to the apical third in the group C but not in the other test groups and controls (P < 0.05). The percentage of new bone were higher at the coronal and apical thirds for Controls and group C compared to A and B groups (P < 0.05). The residual graft was higher for group C (53 ± 1.4%), followed by group B (45 ± 3.1%) and group A (35 ± 1.9%; P < 0.05). The percentages of connective tissue were higher at the middle third without differences between groups (P > 0.05). Within the limitations of this experimental animal study, it might be concluded that grafted sockets compressed with 200 g force will have higher bony contours; higher compressive forces facilitate the penetration of the particulate graft material into the apical area of the socket and results in more bone formation at the coronal, middle, and apical thirds. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. The Effect of Prosthetic Socket Interface Design on Socket Comfort, Residual Limb Health, and Function for the Transfemoral Amputee

    DTIC Science & Technology

    2017-10-01

    significantly lower trim lines, without ischial containment compared with a traditional interface. However, these alternative designs could compromise...overall function compared to the standard of care interface design . Therefore the focus of this clinical trial is to determine if the DS and Sub-I...alternative interface designs will improve socket comfort, residual limb health and function compared to the standard of care IRC interface design . 15

  20. An investigation on effects of amputee's physiological parameters on maximum pressure developed at the prosthetic socket interface using artificial neural network.

    PubMed

    Nayak, Chitresh; Singh, Amit; Chaudhary, Himanshu; Unune, Deepak Rajendra

    2017-10-23

    Technological advances in prosthetics have attracted the curiosity of researchers in monitoring design and developments of the sockets to sustain maximum pressure without any soft tissue damage, skin breakdown, and painful sores. Numerous studies have been reported in the area of pressure measurement at the limb/socket interface, though, the relation between amputee's physiological parameters and the pressure developed at the limb/socket interface is still not studied. Therefore, the purpose of this work is to investigate the effects of patient-specific physiological parameters viz. height, weight, and stump length on the pressure development at the transtibial prosthetic limb/socket interface. Initially, the pressure values at the limb/socket interface were clinically measured during stance and walking conditions for different patients using strain gauges placed at critical locations of the stump. The measured maximum pressure data related to patient's physiological parameters was used to develop an artificial neural network (ANN) model. The effects of physiological parameters on the pressure development at the limb/socket interface were examined using the ANN model. The analyzed results indicated that the weight and stump length significantly affects the maximum pressure values. The outcomes of this work could be an important platform for the design and development of patient-specific prosthetic socket which can endure the maximum pressure conditions at stance and ambulation conditions.

  1. Study of conjunctival flora in anophthalmic patients: influence on the comfort of the socket.

    PubMed

    Toribio, Alvaro; Marrodán, Teresa; Fernández-Natal, Isabel; Martínez-Blanco, Honorina; Rodríguez-Aparicio, Leandro; Ferrero, Miguel Á

    2017-08-01

    To investigate the relationship between conjunctival flora and comfort of the socket in anophthalmic patients. A cross-sectional clinical study including 60 patients with unilateral anophthalmia who wear a prosthetic eye. From each patient three microbiological samples were taken from the lower conjunctival sac (healthy eye, pre-prosthesis, and retro-prosthesis space of socket). The 180 samples obtained were cultured. Samples from a randomized subgroup of 29 patients were measured by spectrophotometry at 540 nm after 48 h of growth, to determine their microbial density (MD). The grade of comfort of the socket (GCS) of each patient was established by a questionnaire. Epidemiological and clinical data of the anophthalmic socket and artificial eye care of each patient were also collected. MD decreased in healthy eyes (0.213 ± 0.201, P = 0.004) compared with the pre-prosthesis (0.402 ± 0.323) and retro-prosthesis (0.438 ± 0.268) samples. Pre-prosthesis MD correlated with retro-prosthesis MD (R = 0.401, P = 0.031) and healthy eye MD (R = 0.482, P = 0.008), and it was also related to poor GCS (P = 0.017). Aerobic Gram-negative bacteria in retro-prosthesis samples of patients with poor GCS was higher than in patients with good or fair GCS (P = 0.008). In the same samples, coagulase-negative staphylococci proportion (excluding S. epidermidis) increased in patients with good GCS (P = 0.030). Socket microflora is related to GCS. Increased pathogenic flora, especially Gram-negative bacteria, and high MD are related to discomfort, while coagulase-negative staphylococci (other than S. epidermidis) are associated with comfort.

  2. Comparison of the effectiveness of two different bone substitute materials for socket preservation after tooth extraction: a controlled clinical study.

    PubMed

    Shakibaie-M, Behnam

    2013-01-01

    The aim of this study was to compare the effectiveness of two bone substitute materials for socket preservation after tooth extraction. Extraction sockets in 10 patients were filled with either inorganic bovine bone material (Bio-Oss) or with synthetic material consisting of hydroxyapatite and silicon dioxide (NanoBone). Extraction sockets without filling served as the control. The results demonstrate the effectiveness of the presented protocol for socket preservation and that the choice of a suitable bone substitute material is crucial. The dimensions of the alveolar ridge were significantly better preserved with Bio-Oss than with NanoBone or without treatment. Bio-Oss treatment resulted in better bone quality and quantity for successful implant placement.

  3. The effects of modeling simplifications on craniofacial finite element models: the alveoli (tooth sockets) and periodontal ligaments.

    PubMed

    Wood, Sarah A; Strait, David S; Dumont, Elizabeth R; Ross, Callum F; Grosse, Ian R

    2011-07-07

    Several finite element models of a primate cranium were used to investigate the biomechanical effects of the tooth sockets and the material behavior of the periodontal ligament (PDL) on stress and strain patterns associated with feeding. For examining the effect of tooth sockets, the unloaded sockets were modeled as devoid of teeth and PDL, filled with teeth and PDLs, or simply filled with cortical bone. The third premolar on the left side of the cranium was loaded and the PDL was treated as an isotropic, linear elastic material using published values for Young's modulus and Poisson's ratio. The remaining models, along with one of the socket models, were used to determine the effect of the PDL's material behavior on stress and strain distributions under static premolar biting and dynamic tooth loading conditions. Two models (one static and the other dynamic) treated the PDL as cortical bone. The other two models treated it as a ligament with isotropic, linear elastic material properties. Two models treated the PDL as a ligament with hyperelastic properties, and the other two as a ligament with viscoelastic properties. Both behaviors were defined using published stress-strain data obtained from in vitro experiments on porcine ligament specimens. Von Mises stress and strain contour plots indicate that the effects of the sockets and PDL material behavior are local. Results from this study suggest that modeling the sockets and the PDL in finite element analyses of skulls is project dependent and can be ignored if values of stress and strain within the alveolar region are not required. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Window Selection Tool | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  5. Efficacy of plasma-rich growth factor in the healing of postextraction sockets in patients affected by insulin-dependent diabetes mellitus.

    PubMed

    Mozzati, Marco; Gallesio, Giorgia; di Romana, Sara; Bergamasco, Laura; Pol, Renato

    2014-03-01

    To evaluate the efficacy of plasma-rich growth factor (PRGF) in improving socket healing after tooth extraction in diabetic patients. This was a split-mouth study in which each patient also served as the control: the study socket was treated with PRGF, whereas the control socket underwent natural healing. The outcome variables were the Healing Index, residual socket volume, visual analog scale score, postsurgical complications, and outcome of a patient questionnaire. The investigation considered the impact of hyperglycemia, glycated hemoglobin, End Organ Disease Score, and smoking habits. Follow-up included 4 postextraction checkups over a 21-day period. Pairs of correlated continuous variables were analyzed with the Wilcoxon test, independent continuous variables with the Mann-Whitney test, and categorical variables with the χ(2) test or Fisher test. From January 2012 to December 2012, 34 patients affected by insulin-dependent diabetes mellitus underwent contemporary bilateral extractions of homologous teeth. The treatment-versus-control postoperative comparison showed that PRGF resulted in significantly smaller residual socket volumes and better Healing Indices from days 3 to 14. The patients' questionnaire outcomes were unanimously in favor of PRGF treatment. The small sample of patients with glycemia values of at least 240 mg/dL showed worse Healing Index and minor socket decreases. PRGF application after extraction improved the healing process in diabetic patients by accelerating socket closure (epithelialization) and tissue maturation, proving the association between PRGF use and improved wound healing in diabetic patients. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. The Quantum Socket: Wiring for Superconducting Qubits - Part 1

    NASA Astrophysics Data System (ADS)

    McConkey, T. G.; Bejanin, J. H.; Rinehart, J. R.; Bateman, J. D.; Earnest, C. T.; McRae, C. H.; Rohanizadegan, Y.; Shiri, D.; Mariantoni, M.; Penava, B.; Breul, P.; Royak, S.; Zapatka, M.; Fowler, A. G.

    Quantum systems with ten superconducting quantum bits (qubits) have been realized, making it possible to show basic quantum error correction (QEC) algorithms. However, a truly scalable architecture has not been developed yet. QEC requires a two-dimensional array of qubits, restricting any interconnection to external classical systems to the third axis. In this talk, we introduce an interconnect solution for solid-state qubits: The quantum socket. The quantum socket employs three-dimensional wires and makes it possible to connect classical electronics with quantum circuits more densely and accurately than methods based on wire bonding. The three-dimensional wires are based on spring-loaded pins engineered to insure compatibility with quantum computing applications. Extensive design work and machining was required, with focus on material quality to prevent magnetic impurities. Microwave simulations were undertaken to optimize the design, focusing on the interface between the micro-connector and an on-chip coplanar waveguide pad. Simulations revealed good performance from DC to 10 GHz and were later confirmed against experimental measurements.

  7. Socket preservation using freeze-dried bone allograft with and without plasma rich in growth factors in dogs

    PubMed Central

    Samandari, Mohammad Hasan; Haghighat, Abbas; Torabinia, Nakisa; Taghian, Mehdi; Sadri, Leyli; Naemy, Vahid

    2016-01-01

    Background: Plasma rich in growth factors (PRGF) and freeze-dried bone allograft (FDBA) are shown to promote bone healing. This study was aimed to histologically and histomorphometrically investigate the effect of combined use of PRGF and FDBA on bone formation, and compare it to FDBA alone and control group. Materials and Methods: The distal roots of the lower premolars were extracted bilaterally in four female dogs. Sockets were randomly divided into FDBA + PRGF, FDBA, and control groups. Two dogs were sacrificed after 2 weeks and two dogs were sacrificed after 4 weeks. Sockets were assessed histologically and histomorphometrically. Data were analyzed by Kruskal–Wallis test followed by Mann–Whitney U-tests utilizing the SPSS software version 20. P < 0.05 was considered statistically significant. Results: While the difference in density of fibrous tissue in three groups was not statistically significant (P = 0.343), the bone density in grafted groups was significantly higher than the control group (P = 0.021). The least decrease in all socket dimensions was observed in the FDBA group. However, these differences were only significant in coronal portion at week 4. Regarding socket dimensions and bone density, the difference between FDBA and FDBA+PRGF groups was not significant in middle and apical portions. Conclusion: The superiority of PRGF+FDBA overFDBA in socket preservation cannot be concluded from this experiment. PMID:27857769

  8. Effect of socket grafting with deproteinized bone mineral: An RCT on dimensional alterations after 6 months.

    PubMed

    Tomasi, Cristiano; Donati, Mauro; Cecchinato, Denis; Szathvary, Isacco; Corrà, Enrico; Lindhe, Jan

    2018-05-01

    To examine if (i) characteristics of the fresh extraction socket site influenced subsequent dimensional alterations and (ii) placement of deproteinized bovine mineral in the socket affected volumetric change during healing. Twenty seven subjects and 28 extraction sites were included. Immediately after the removal of the tooth and after 6 months of healing, stone and virtual models of the jaw were produced. A cone beam computerized tomography scan was obtained immediately after extraction and the thickness of the buccal bone wall at the extraction site was measured. Extraction sites were randomly assigned to test or control group. In the test group, extraction sockets were filled with deproteinized bone mineral and covered with a collagen membrane. In the control group, only a collagen membrane was placed. The thickness of the buccal bone wall at the extraction site influenced the amount of volume reduction that occurred. Socket grafting influenced the degree of ridge diminution only at sites where the buccal bone wall was thin (≤ 1 mm). A graft comprised of collagen-enriched deproteinized bovine bone mineral, placed to fill extraction sockets failed to influence the overall diminution of the ridge that occurred during healing. The thickness of the buccal bone wall apparently had a significant influence on volumetric alterations of the edentulous ridge following tooth extraction. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. 34. DETAIL OF APRONTOFLOAT LOCKING PIN SOCKETS AND SUSPENSION CABLES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. DETAIL OF APRON-TO-FLOAT LOCKING PIN SOCKETS AND SUSPENSION CABLES ON BRIDGE NO. 9. LOOKING NORTH. - Greenville Yard, Transfer Bridge System, Port of New York/New Jersey, Upper New York Bay, Jersey City, Hudson County, NJ

  10. Vibrational fatigue failures in short cantilevered piping with socket-welding fittings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, J.K.

    1996-12-01

    Approximately 80% of the vibrational fatigue failures in nuclear power plants have been caused by high cycle vibrational fatigue. Many of these failures have occurred in short, small bore (2 in. nominal diameter and smaller), unbraced, cantilevered piping with socket-welding fittings. The fatigue failures initiated in the socket welds. These failures have been unexpected, and have caused costly, unscheduled outages in some cases. In order to reduce the number of vibrational fatigue failures in these short cantilevered pipes, an acceleration based vibrational fatigue screening criteria was developed under Electric Power Research Institute (EPRI) sponsorship. In this paper, the acceleration basedmore » criteria will be compared to the results obtained from detailed dynamic modeling of a short, cantilevered pipe.« less

  11. Topical combined application of dexamethasone, vitamin C, and β-sodium glycerophosphate for healing the extraction socket in rabbits.

    PubMed

    Chen, J; He, Y; Shan, C; Pan, Q; Li, M; Xia, D

    2015-10-01

    An osteogenic inducer (OI) consisting of dexamethasone, vitamin C, and β-sodium glycerophosphate has the capacity to induce bone formation in vitro. The aim of this study was to assess the efficacy of the application of this OI on extraction socket healing. The bilateral first mandibular premolars were extracted from 75 New Zealand rabbits. Gelatin sponges carrying OI were implanted into the sockets. Sockets undergoing implantation of gelatin sponges alone were also evaluated, as well as non-implantation sockets. Specimens from each group were evaluated radiographically, histologically, and histomorphometrically using haematoxylin-eosin staining. Results showed earlier new bone formation and higher bone quality and quantity in the OI group compared to the other groups, and the differences were significant at 2, 4, 8, and 12 weeks postoperative. The OI significantly reduced the absorption of alveolar bone in terms of height; however, changes in the width were not significantly different between the three groups (P>0.05). The OI was shown to have a positive effect on healing of the tooth extraction sockets, was inexpensive, and was convenient to use during the operational procedure; therefore this could represent a promising implant material for human clinical application. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Common risk factors of dry socket (alveolitis osteitis) following dental extraction: A brief narrative review.

    PubMed

    Rakhshan, V

    2018-04-30

    Dry socket is a common complication of dental extraction, especially extraction of third molars. Knowledge of the frequent risk factors of alveolitis osteitis is useful in determining high-risk patients, treatment planning, and preparing the patients mentally. The aim of this narrative review was to summarize the common risk factors of dry socket. Unlike surgery difficulty, surgeon's experience, oral contraception use, and oral hygiene which showed stronger evidence, the influences of age, gender, and smoking were rather inconclusive. The case of female or oral contraceptive effect might relate mainly to estrogen levels (when it comes to dry socket) which can differ considerably from case to case. Many risk factors might be actually a combination of various independent variables, which should be targeted instead, in more comprehensive designs. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  13. Early healing in alveolar sockets grafted with titanium granules. An experimental study in a dog model.

    PubMed

    Arruda, Thiago; Sukekava, Flávia; de Souza, André B; Rasmusson, Lars; Araújo, Maurício G

    2013-07-01

    The aim of the present study was to evaluate the effect of the placement of titanium granules in fresh extraction sockets on early bone formation. The mesial roots of the third maxillary premolars of five adult beagle dogs were removed. On one side of the maxilla (Test group) the fresh extraction socket was grafted with titanium granules, while the contra-lateral socket was left non-grafted (Control group). After 1 month of healing, the dogs were euthanized and biopsies were obtained. The healing tissues were described, and histometric measurements were performed to obtain the percentage area occupied by connective tissue, new mineralized bone, bone marrow, and biomaterial particles. After 1 month of healing the findings from the histological examination revealed the titanium graft to be well incorporated into the provisional connective tissue or newly formed woven bone. The histometric measurements showed, however, that less mineralized bone was formed in the Test group than in the Control group. The present study suggests that the use of titanium granules in fresh extraction sockets was conducive to new bone formation. The graft of titanium granules seems, however, to delay the early phase of the healing process. Copyright © 2012 Wiley Periodicals, Inc.

  14. Socket preservation using bovine bone mineral and collagen membrane: a randomized controlled clinical trial with histologic analysis.

    PubMed

    Cardaropoli, Daniele; Tamagnone, Lorenzo; Roffredo, Alessandro; Gaveglio, Lorena; Cardaropoli, Giuseppe

    2012-08-01

    After tooth extraction, varying amounts of bone resorption occur because of qualitative and quantitative changes at the edentulous site of the alveolar process. The aims of this randomized controlled clinical trial were (1) to compare the postextraction changes in residual ridge dimensions during spontaneous healing with those during socket preservation, (2) to analyze the histologic and histomorphometric aspects of the grafted sockets, and (3) to compare probing procket depth (PPD) and clinical attachment level (CAL) changes at teeth adjacent to extraction sites. Forty-eight teeth were extracted from 41 patients referred for extraction of 1 or more maxillary or mandibular premolars or molars. The edentulous sites were randomly assigned to the control (EXT, extraction alone) or experimental groups (SP, extraction and socket preservation). In the SP group, the sockets were filled with bovine bone mineral and covered with porcine collagen membrane. At baseline and after 4 months, PPD, gingival recession (REC), and CAL were measured at teeth adjacent to the edentulous sites. The changes in ridge dimensions from baseline to 4 months were assessed on dental casts. At 4 months, bone was harvested from the grafted areas in the SP group and the edentulous areas in the EXT group. PPD, REC, and CAL were comparable between groups. However, from baseline to 4 months, the SP group showed significantly less reduction in ridge width (1.04 ± 1.08 mm vs 4.48 ± 0.65 mm, P < .001) and height (0.46 ± 0.46 mm vs 1.54 ± 0.33 mm, P < .001). Histologically, the grafted sockets exhibited various stages of bone maturation and formation without inflammatory responses. No significant difference in the mineralized and nonmineralized fractions was noted between the groups. Socket preservation using bovine bone mineral and porcine collagen membrane considerably limits the amount of horizontal and vertical bone resorption when compared with extraction alone.

  15. Influence of sampling window size and orientation on parafoveal cone packing density

    PubMed Central

    Lombardo, Marco; Serrao, Sebastiano; Ducoli, Pietro; Lombardo, Giuseppe

    2013-01-01

    We assessed the agreement between sampling windows of different size and orientation on packing density estimates in images of the parafoveal cone mosaic acquired using a flood-illumination adaptive optics retinal camera. Horizontal and vertical oriented sampling windows of different size (320x160 µm, 160x80 µm and 80x40 µm) were selected in two retinal locations along the horizontal meridian in one eye of ten subjects. At each location, cone density tended to decline with decreasing sampling area. Although the differences in cone density estimates were not statistically significant, Bland-Altman plots showed that the agreement between cone density estimated within the different sampling window conditions was moderate. The percentage of the preferred packing arrangements of cones by Voronoi tiles was slightly affected by window size and orientation. The results illustrated the high importance of specifying the size and orientation of the sampling window used to derive cone metric estimates to facilitate comparison of different studies. PMID:24009995

  16. Soft Tissue Closure of Grafted Extraction Sockets in the Anterior Maxilla: A Modified Palatal Pedicle Connective Tissue Flap Technique.

    PubMed

    El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole

    Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.

  17. A Novel Chitosan-γPGA Polyelectrolyte Complex Hydrogel Promotes Early New Bone Formation in the Alveolar Socket Following Tooth Extraction

    PubMed Central

    Chang, Hao-Hueng; Wang, Yin-Lin; Chiang, Yu-Chih; Chen, Yen-Liang; Chuang, Yu-Horng; Tsai, Shang-Jye; Heish, Kuo-Huang; Lin, Feng-Huei; Lin, Chun-Pin

    2014-01-01

    A novel chitosan-γPGA polyelectrolyte complex hydrogel (C-PGA) has been developed and proven to be an effective dressing for wound healing. The purpose of this study was to evaluate if C-PGA could promote new bone formation in the alveolar socket following tooth extraction. An animal model was proposed using radiography and histomorphology simultaneously to analyze the symmetrical sections of Wistar rats. The upper incisors of Wistar rats were extracted and the extraction sockets were randomly treated with gelatin sponge, neat chitosan, C-PGA, or received no treatment. The extraction sockets of selected rats from each group were evaluated at 1, 2, 4, or 6 wk post-extraction. The results of radiography and histopathology indicated that the extraction sockets treated with C-PGA exhibited lamellar bone formation (6.5%) as early as 2 wk after the extraction was performed. Moreover, the degree of new bone formation was significantly higher (P < 0.05) in the extraction sockets treated with C-PGA at 6 wk post-extraction than that in the other study groups. In this study, we demonstrated that the proposed animal model involving symmetrical sections and simultaneous radiography and histomorphology evaluation is feasible. We also conclude that the novel C-PGA has great potential for new bone formation in the alveolar socket following tooth extraction. PMID:24658174

  18. A shot through the window.

    PubMed

    Burnett, B R

    2001-03-01

    At issue in this case was whether an unusual window defect seen in two of the crime scene photographs was due to a bullet and if so, if that same bullet fatally wounded the victim. The window appeared to have been cracked prior to the apparent shot through it. A .22 bullet recovered from autopsy, when examined only by light microscopy, failed to show associated glass fragments. A previously cracked test window was shot a number of times with .22 caliber bullets near the cracks in an effort to simulate the window defect seen in the crime scene photographs. Several of the defects produced by the test window shots appeared similar to the crime scene window defect. The .22 bullet taken from the victim and several of the test bullets (collected by a cotton box) were examined by scanning electron microscopy/energy dispersive X-ray spectroscopy. The test bullets showed glass particles on and embedded in their surfaces. Particles of similar size and composition were found embedded in the surface of the bullet from the victim. The bullet likely struck the window prior to hitting the victim. It was apparent by the morphology of some of the mushroomed test .22 bullets that they hit the window crack. These bullets showed that the glass on one side of a crack often fails before the other side during the strike. Aggregations of powdered glass on many of the mushroomed surfaces of the .22 bullets suggest that as the bullet mushrooms during impact on the window surface, the glass in contact with the bullet powderizes and coats the mushroomed surface of the bullet with a layer of fine glass particles.

  19. Biomechanical Effects of the Geometry of Ball-and-Socket Artificial Disc on Lumbar Spine: A Finite Element Study.

    PubMed

    Choi, Jisoo; Shin, Dong-Ah; Kim, Sohee

    2017-03-15

    A three-dimensional finite element model of intact lumbar spine was constructed and four surgical finite element models implanted with ball-and-socket artificial discs with four different radii of curvature were compared. To investigate biomechanical effects of the curvature of ball-and-socket artificial disc using finite element analysis. Total disc replacement (TDR) has been accepted as an alternative treatment because of its advantages over spinal fusion methods in degenerative disc disease. However, the influence of the curvature of artificial ball-and-socket discs has not been fully understood. Four surgical finite element models with different radii of curvature of ball-and-socket artificial discs were constructed. The range of motion (ROM) increased with decreasing radius of curvature in extension, flexion, and lateral bending, whereas it increased with increasing radius of curvature in axial torsion. The facet contact force was minimum with the largest radius of curvature in extension, flexion, and lateral bending, whereas it was maximum with the largest radius in axial torsion. It was also affected by the disc placement, more with posterior placement than anterior placement. The stress in L4 cancellous bone increased when the radius of curvature was too large or small. The geometry of ball-and-socket artificial disc significantly affects the ROM, facet contact force, and stress in the cancellous bone at the surgical level. The implication is that in performing TDR, the ball-and-socket design may not be ideal, as ROM and facet contact force are sensitive to the disc design, which may be exaggerated by the individual difference of anatomical geometry. N/A.

  20. Effectiveness of platelet-rich fibrin in the management of pain and delayed wound healing associated with established alveolar osteitis (dry socket).

    PubMed

    Sharma, Ashish; Aggarwal, Nimish; Rastogi, Sanjay; Choudhury, Rupshikha; Tripathi, Siddhi

    2017-01-01

    To assess the efficacy of platelet-rich fibrin (PRF) on the pain and healing of the extraction socket related with established alveolar osteitis (dry socket, AO) after the removal of maxillary and mandibular molars. One hundred consecutive adult patients with age group ranging from 18 to 40 years along with established dry socket after maxillary and mandibular molar extractions who have not received any treatment for the same were included in this single-arm clinical trial. PRF was placed in the maxillary and mandibular molar extraction sockets after adequate irrigation of the socket. All the patients evaluated for the various study variables which include pain, degree of inflammation, and healthy granulation tissue formation (wound healing) at the 1 st , 3 rd , 7 th , and 14 th post-PRF placement day in the alveolar socket. Data were analyzed using Shapiro-Wilk's test, Chi-square test and/or Student's t -test, Friedman's test, Wilcoxon signed-rank test, and Bonferroni test, with the significance level set at P < 0.05. There was significant reduction in pain associated with AO at the 3 rd and 7 th post-PRF placement day in the extraction socket along with mark decrease in the degree of inflammation at the 3 rd post-PRF placement day, and there was better wound healing by the end of the 2 nd week. The use of PRF in this clinical trial illustrates the promising results in terms of reduced pain and better healing in the patients with sustained AO.

  1. Deepening Fornix Technique Using Central Split-Medium Thickness Skin Graft to Treat Contracted Anophthalmic Sockets.

    PubMed

    AlHassan, Sultan; Galindo-Ferreiro, Alicia; Khandekar, Rajiv; AlShaikh, Osama; Schellini, Silvana Artioli

    2018-05-08

    The aim of thhis study was to present the outcomes of postauricular split-medium thickness skin graft (SMTSG) to treat anophthalmic sockets with contracted fornices. This case series enrolled patients with grade 2 or 3 anophthalmic sockets between 2015 and 2016. Data were collected on patient demographics, objective and subjective parameters preoperatively and 180 days postoperatively. Success of the surgery was graded on the height of the graft, the depth of the superior and inferior fornices, and presence/abscence of lagophthalmos, entropion, and ability to retain an external prosthesis. Eighteen patients were enrolled with a mean age of 35.9 ± 18 years. The median height of the graft was 22 mm (25% quartile = 18.75) when removed and 20 mm (25% quartile = 16) postoperatively. The median depth of the superior fornix was 6.5 mm (25% quartile = 4.5 mm) preoperatively and 10 mm (25% quartile = 8 mm) postoperatively (P = 0.5). The median inferior fornix depth was 7 mm (25% quartile = 3.5 mm) preoperatively and 8 mm (25% quartile = 5 mm) (P = 0.27) postoperatively. Preoperatively, there were 13 (72.2%) patients with lagophthalmos, 10 (44.4%) with entropion, 3 (37.5%) with poor prosthesis retention, and 5 (62.5%) who were unable to retain the prosthesis. Postoperatively, 7 (38.9%) patients had lagophthamos, 1 (5.6%) had entropion, and all the patients could retain the prosthesis. None of the sockets had a foul odor postoperatively. Postauricular SMTSG achieves successful outcomes for the treatment of contracted anophthalmic sockets, reshaping the anterior socket surface and deepening the fornices.

  2. Remote monitoring of lower-limb prosthetic socket fit using wireless technologies.

    PubMed

    Sahandi, R; Sewell, P; Noroozi, S; Hewitt, M

    2012-01-01

    Accurate fitting of a lower-limb prosthetic socket is the most important factor affecting amputee satisfaction and rehabilitation. The technology is now available to allow real-time monitoring of in-service pressure distribution of prosthetic limbs. This paper proposes a remote interfacial pressure monitoring system necessary for the assessment of fit. The suitability of a wireless ZigBee network due to its relevant technical specification is investigated. The system enables remote monitoring of a prosthetic socket and its fit under different operating conditions thereby improving design, efficiency and effectiveness. The data can be used by prosthetists and may also be recorded for future training or for patient progress monitoring. This can minimize the number of iterations by getting it right first time, thereby minimizing the number of replacement prostheses. Copyright © 2012 Informa UK, Ltd.

  3. A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

    PubMed

    Cagle, John C; Reinhall, Per G; Allyn, Kate J; McLean, Jake; Hinrichs, Paul; Hafner, Brian J; Sanders, Joan E

    2017-12-13

    People with transtibial amputation often experience skin breakdown due to the pressures and shear stresses that occur at the limb-socket interface. The purpose of this research was to create a transtibial finite element model (FEM) of a contemporary prosthesis that included complete socket geometry, two frictional interactions (limb-liner and liner-socket), and an elastomeric liner. Magnetic resonance imaging scans from three people with characteristic transtibial limb shapes (i.e., short-conical, long-conical, and cylindrical) were acquired and used to develop the models. Each model was evaluated with two loading profiles to identify locations of focused stresses during stance phase. The models identified five locations on the participants' residual limbs where peak stresses matched locations of mechanically induced skin issues they experienced in the 9 months prior to being scanned. The peak contact pressure across all simulations was 98 kPa and the maximum resultant shear stress was 50 kPa, showing reasonable agreement with interface stress measurements reported in the literature. Future research could take advantage of the developed FEM to assess the influence of changes in limb volume or liner material properties on interface stress distributions. Graphical abstract Residual limb finite element model. Left: model components. Right: interface pressures during stance phase.

  4. Comparison of immediate implant placement in infected and non-infected extraction sockets: a systematic review and meta-analysis.

    PubMed

    Lee, Jungwon; Park, Dueun; Koo, Ki-Tae; Seol, Yang-Jo; Lee, Yong-Moo

    2018-04-03

    This review aimed to investigate the feasibility of immediate implant placement in infected extraction sockets. We performed electronic and manual searches up to March 2017 to obtain data from randomized controlled trials (RCTs) and nonrandomized controlled clinical trials (CCTs). Using a fixed-effects model to assess the difference in survival rate (primary outcome), we evaluated the risk difference for immediate implant placement in infected and non-infected sites. We estimated the weighted mean differences (WMDs) of the change in marginal bone loss (MBL), probing depth (PD), modified bleeding index (mBI), marginal gingival level (MGL) and width of keratinized gingiva (WKG) at baseline and latest follow-up. In total, five studies (0 RCT, five CCTs) were included in the systematic review and three studies were included in the meta-analysis. The risk difference for immediate implant placement in an infected extraction socket compared with that in a non-infected socket was -0.02. WMDs for MBL, PD, mBI, MGL and WKG between the two groups were 0.32, 0.12, 0.07, -0.06, 0.20 and 0.51, respectively. No statistical differences were observed between the two groups, except for the change in WKG. Implants can be placed in infected extraction sockets after thorough socket debridement. For aesthetics, WKG should be considered when performing immediate implant placement in infected sites.

  5. Benefits of Efficient Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  6. Windows for New Construction | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  7. Performance Standards for Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  8. Assessing Window Replacement Options | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  9. Performance enhancement of epoxy based sandwich composites using multiwalled carbon nanotubes for the application of sockets in trans-femoral amputees.

    PubMed

    Arun, S; Kanagaraj, S

    2016-06-01

    A socket plays a vital role in giving the comfort to the amputees. However, the accumulation of heat inside the socket and its weight led to increase their metabolic cost. Hence, an attempt was made to increase the performance of the epoxy based sandwich composites to be used for the socket by reinforcing multiwalled carbon nanotubes (MWCNT), which was varied from 0.1 to 0.5wt%. It was homogeneously dispersed in epoxy to obtain the desired properties, where the enhancement of thermal conductivity, compressive strength and modulus of epoxy was observed to be 76.7%, 62.6% and 20.2%, respectively at 0.3wt% of MWCNT concentration beyond which the mechanical properties were found to be decreased. Hence, the epoxy, E-glass plain fabric, 2-10 layers of stockinet and 0.3wt% of MWCNT were used to prepare the sandwich composites. The flexural strength and thermal conductivity of 0.3wt% of MWCNT reinforced sandwich composites were found to be improved by 11.38±1.5% and 29.8±1.3% for the 4-10 layers and up to 10 layers of stockinet, respectively compared to unreinforced sandwich composites, which helped to reduce the weight of the socket and decrease the heat accumulation inside the socket. Thus, it is suggested to be explored for the application of socket in trans-femoral amputees to increase their comfort level by decreasing the metabolic cost. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Healing of extraction sockets filled with BoneCeramic® prior to implant placement: preliminary histological findings.

    PubMed

    De Coster, Peter; Browaeys, Hilde; De Bruyn, Hugo

    2011-03-01

    Various grafting materials have been designed to minimize edentulous ridge volume loss following tooth extraction by encouraging new bone formation in healing sockets. BoneCeramic® is a composite of hydroxyapatite and bèta-tricalcium phosphate with pores of 100-500 microns. The aim of this study was to evaluate bone regeneration in healing sockets substituted with BoneCeramic® prior to implant procedures. Fifteen extraction sockets were substituted with BoneCeramic® and 14 sockets were left to heal naturally in 10 patients (mean age 59.6 years). Biopsies were collected only from the implant recipient sites during surgery after healing periods ranging from 6-74 weeks (mean 22). In total, 24 biopsies were available; 10 from substituted and 14 from naturally healed sites. In one site, the implant was not placed intentionally and, in four substituted sites, implant placement had to be postponed due to inappropriate healing, hence from five sites biopsies were not available. Histological sections were examined by transmitted light microscope. At the time of implant surgery, bone at substituted sites was softer than in controls, compromising initial implant stability. New bone formation at substituted sites was consistently poorer than in controls, presenting predominantly loose connective tissue and less woven bone. The use of BoneCeramic® as a grafting material in fresh extraction sockets appears to interfere with normal healing processes of the alveolar bone. On the basis of the present preliminary findings, its indication as a material for bone augmentation, when implant placement is considered within 6-38 weeks after extraction, should be revised. © 2009, Copyright the Authors. Journal Compilation © 2011, Wiley Periodicals, Inc.

  11. Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects.

    PubMed

    Jia, Xiaohong; Zhang, Ming; Lee, Winson C C

    2004-09-01

    The effects of inertial loads on the interface stresses between trans-tibial residual limb and prosthetic socket were investigated. The motion of the limb and prosthesis was monitored using a Vicon motion analysis system and the ground reaction force was measured by a force platform. Equivalent loads at the knee joint during walking were calculated in two cases with and without consideration of the material inertia. A 3D nonlinear finite element (FE) model based on the actual geometry of residual limb, internal bones and socket liner was developed to study the mechanical interaction between socket and residual limb during walking. To simulate the friction/slip boundary conditions between the skin and liner, automated surface-to-surface contact was used. The prediction results indicated that interface pressure and shear stress had the similar double-peaked waveform shape in stance phase. The average difference in interface stresses between the two cases with and without consideration of inertial forces was 8.4% in stance phase and 20.1% in swing phase. The maximum difference during stance phase is up to 19%. This suggests that it is preferable to consider the material inertia effect in a fully dynamic FE model.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ronald W.

    With the addition of the 3D volume slicer widget, VERAView now relies on Mayavi and its dependents. Enthought's Canopy Python environment provides everything VERAView needs, and pre-built Canopy versions for Windows, Mac OSX, and Linux can be downloaded.

  13. Laboratory Investigation of a Leaking Type 316 Socket Weld in a Boron Injection Tank Sampling Line

    NASA Astrophysics Data System (ADS)

    Xu, Hongqing; Fyfitch, Steve; Hosier, Ryan; Hyres, James

    A leak was discovered in a Type 316 stainless steel socket weld in the sampling line for the boron injection tank. A section of the pipeline containing the leaking weld was removed for laboratory investigation that included visual and Stereovisual inspections, liquid penetrant (PT) testing, metallography, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and ferrite content determinations. The leak path was a through-wall transgranular crack in the socket weld. Cracking initiated along the weld-metal-to-base-metal interface at the tip of the crevice between the socket and pipe. The crevice was exposed to oxygenated boron solution at <180°F. Shallow intergranular attack (IGA) was found in the exposed base metal inside the crevice. Based on the investigation results, it was concluded that transgranular stress corrosion cracking (TGSCC) is the primary cracking mechanism.

  14. Spatial coherence measurements and x-ray holographic imaging using a laser-generated plasma x-ray source in the water window spectral region

    NASA Astrophysics Data System (ADS)

    Turcu, I. C. E.; Ross, I. N.; Schulz, M. S.; Daido, H.; Tallents, G. J.; Krishnan, J.; Dwivedi, L.; Hening, A.

    1993-06-01

    The properties of a coherent x-ray point source in the water window spectral region generated using a small commercially available KrF laser system focused onto a Mylar (essentially carbon) target have been measured. By operating the source in a low-pressure (approximately 20 Torr) nitrogen environment, the degree of monochromaticity was improved due to the nitrogen acting as an x-ray filter and relatively enhancing the radiation at a wavelength of 3.37 nm (C vi 1s-2p). X-ray pinhole camera images show a minimum source size of 12 μm. A Young's double slit coherence measurement gave fringe visibilities of approximately 62% for a slit separation of 10.5 μm at a distance of 31.7 cm from the source. To demonstrate the viability of the laser plasma as a source for coherent imaging applications a Gabor (in-line) hologram of two carbon fibers, of different sizes, was produced. The exposure time and the repetition rate was 2 min and 10 Hz, respectively.

  15. Comparison of bone-anchored prostheses and socket prostheses for patients with a lower extremity amputation: a systematic review.

    PubMed

    Leijendekkers, Ruud A; van Hinte, Gerben; Frölke, Jan Paul; van de Meent, Hendrik; Nijhuis-van der Sanden, Maria W G; Staal, J Bart

    2017-06-01

    This study aimed to provide an overview of a) the used measurement instruments in studies evaluating effects on quality of life (QoL), function, activity and participation level in patients with a lower extremity amputation using bone-anchored prostheses compared to socket prostheses and b) the effects themselves. A systematic literature search was conducted in MEDLINE, Cochrane, EMBASE, CINAHL and Web of Science. Included studies compared QoL, function, activity and/or participation level in patients with bone-anchored or socket prostheses. A best-evidence synthesis was performed. Out of 226 studies, five cohort and two cross-sectional studies were eligible for inclusion, all had methodological shortcomings. These studies used 10 different measurement instruments and two separate questions to assess outcome. Bone-anchored prostheses were associated with better condition-specific QoL and better outcomes on several of the physical QoL subscales, outcomes on the physical bodily pain subscale were inconclusive. Outcomes on function and activity level increased, no change was found at participation level. The level of evidence was limited. There is a need for a standard set of instruments. There was limited evidence that bone-anchored prostheses resulted in higher QoL, function and activity levels than socket prostheses, in patients with socket-related problems. Implications for Rehabilitation Use of bone-anchored prostheses in combination with intensive outpatient rehabilitation may improve QoL, function and activity level compared with socket prosthesis use in patients with a transfemoral amputation and socket-related problems. All clinicians and researchers involved with bone-anchored prostheses should use and publish data on QoL, function, activity and participation level. There needs to be an agreement on a standard set of instruments so that interventions for patients with a lower extremity amputation are assessed consistently.

  16. VIS-IR transmitting BGG glass windows

    NASA Astrophysics Data System (ADS)

    Bayya, Shyam S.; Chin, Geoff D.; Sanghera, Jasbinder S.; Aggarwal, Ishwar D.

    2003-09-01

    BaO-Ga2O3-GeO2 (BGG) glasses have the desired properties for various window applications in the 0.5-5 μm wavelength region. These glasses are low cost alternatives to the currently used window materials. Fabrication of a high optical quality 18" diameter BGG glass window has been demonstrated with a transmitted wave front error of λ/10 at 632 nm. BGG substrates have also been successfully tested for environmental weatherability (MIL-F-48616) and rain erosion durability up to 300 mph. Preliminary EMI grids have been successfully applied on BGG glasses demonstrating attenuation of 20dB in X and Ku bands. Although the mechanical properties of BGG glasses are acceptable for various window applications, it is demonstrated here that the properties can be further improved significantly by the glassceramization process. The ceramization process does not add any significant cost to the final window material. The crystallite size in the present glass-ceramic limits its transmission to the 2-5 μm region.

  17. VLBI-resolution radio-map algorithms: Performance analysis of different levels of data-sharing on multi-socket, multi-core architectures

    NASA Astrophysics Data System (ADS)

    Tabik, S.; Romero, L. F.; Mimica, P.; Plata, O.; Zapata, E. L.

    2012-09-01

    A broad area in astronomy focuses on simulating extragalactic objects based on Very Long Baseline Interferometry (VLBI) radio-maps. Several algorithms in this scope simulate what would be the observed radio-maps if emitted from a predefined extragalactic object. This work analyzes the performance and scaling of this kind of algorithms on multi-socket, multi-core architectures. In particular, we evaluate a sharing approach, a privatizing approach and a hybrid approach on systems with complex memory hierarchy that includes shared Last Level Cache (LLC). In addition, we investigate which manual processes can be systematized and then automated in future works. The experiments show that the data-privatizing model scales efficiently on medium scale multi-socket, multi-core systems (up to 48 cores) while regardless of algorithmic and scheduling optimizations, the sharing approach is unable to reach acceptable scalability on more than one socket. However, the hybrid model with a specific level of data-sharing provides the best scalability over all used multi-socket, multi-core systems.

  18. Dimensional Changes of Fresh Sockets With Reactive Soft Tissue Preservation: A Cone Beam CT Study.

    PubMed

    Crespi, Roberto; Capparé, Paolo; Crespi, Giovanni; Gastaldi, Giorgio; Gherlone, Enrico Felice

    2017-06-01

    The aim of this study was to assess dimensional changes of the fresh sockets grafted with collagen sheets and maintenance of reactive soft tissue, using cone beam computed tomography (CBCT). Tooth extractions were performed with maximum preservation of the alveolar housing, reactive soft tissue was left into the sockets and collagen sheets filled bone defects. Cone beam computed tomography were performed before and 3 months after extractions. One hundred forty-five teeth, 60 monoradiculars and 85 molars, were extracted. In total, 269 alveoli were evaluated. In Group A, not statistically significant differences were found between monoradiculars, whereas statistically significant differences (P < 0.05) were found between molars, both for mesial and distal alveoli. In Group B, not statistically significant differences were found between maxillary and mandibular bone changes values (P > 0.05) for all types of teeth. This study reported an atraumatic tooth extraction, reactive soft tissue left in situ, and grafted collagen sponge may be helpful to reduce fresh socket collapse after extraction procedures.

  19. Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees

    NASA Astrophysics Data System (ADS)

    Al-Fakih, Ebrahim; Arifin, Nooranida; Pirouzi, Gholamhossein; Mahamd Adikan, Faisal Rafiq; Shasmin, Hanie Nadia; Abu Osman, Noor Azuan

    2017-08-01

    This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction.

  20. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2016-12-01

    of the frame from the combined image files and ensure total contact between the frame geometry, ultimately modeled independently as a solid, and...fitting with a rigid PETG check socket to ensure correct volumes and total contact at the distal end has been achieved, a second check socket can be...from dynamically conforming to changes in residual limb shape and volume during gait (Sanders, 2009). The ensuing separation (i.e. loss of contact

  1. Influence of immediate post-extraction socket irrigation on development of alveolar osteitis after mandibular third molar removal: a prospective split-mouth study, preliminary report.

    PubMed

    Tolstunov, L

    2012-12-01

    The aim of this prospective comparative split-mouth study was to evaluate the role of socket irrigation with a normal saline solution routinely used at the end of extraction on the development of alveolar osteitis (AO) after removal of impacted mandibular third molars (MTMs). Thirty-five patients who satisfied the inclusion criteria were involved in the study and underwent extraction of four third-molars. To be included in the study, the mandibular third molars had to be impacted (partial or full bone) and require an osteotomy for extraction with use of a motorised drill. All surgeries were done under local anaesthesia or IV sedation. This was a prospective split-mouth study. The patient's left (assistant) side was a control side; it had a standard extraction technique of an impacted mandibular third molar that required a buccal full-thickness flap, buccal trough (osteotomy) and extraction of the tooth (with or without splitting the tooth into segments), followed by a traditional end-of-surgery debridement protocol consisting of a gentle curettage, bone filing of the socket walls, socket irrigation with approximately 5 ml of sterile normal saline solution and socket suctioning. The patient's right (operator) side was an experimental side; it also had a standard extraction technique of an impacted mandibular third molar at the beginning with a flap and osteotomy, but it was followed by a modified end-of-surgery protocol. It consisted of gentle curettage but the socket was not irrigated and not suctioned. It was simply left to bleed. The gauze was placed on top of the socket for haemostasis on both sides and the patient was asked to bite. On both sides, the buccal flap was positioned back without the suture. All patients were seen for a follow-up appointment four to seven days after the surgery to assess healing and check for symptoms and signs of alveolar osteitis, if present, on both irrigated and non-irrigated sides. This study followed the ethical guidelines of

  2. Continuation of down-hole geophysical testing for rock sockets : [technical summary].

    DOT National Transportation Integrated Search

    2013-11-01

    The rock socket is critical to a drilled shaft : foundation because it lies within a rock stratum : and accounts for much of the capacity of the : foundational unit. Consistency of the rocks : structure and composition must be identifed : because ...

  3. [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

    PubMed

    Lecuire, F; Benareau, I; Rubini, J; Basso, M

    2004-05-01

    The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk

  4. Development of a socketed foundation for cable barrier posts : phase I.

    DOT National Transportation Integrated Search

    2012-02-01

    Four socketed foundation designs were evaluated for use as a new reusable base for high-tension, cable barrier : systems. Each foundation was a reinforced concrete cylindrical shape. The top of the foundation had an open steel tube to : accept the po...

  5. Buccal bone deficiency in fresh extraction sockets: a prospective single cohort study.

    PubMed

    Barone, Antonio; Ricci, Massimiliano; Romanos, Georgios E; Tonelli, Paolo; Alfonsi, Fortunato; Covani, Ugo

    2015-07-01

    The purpose of this prospective single cohort study was to evaluate the use of xenograft and collagen membranes in treating full or partial buccal bone defects of fresh extraction sockets in the esthetic zone. Thirty-three patients requiring tooth extraction in the anterior maxillary area and showing a complete or partial buccal bone plate deficiency (more than 2 mm) were consecutively enrolled and treated. Corticocancellous porcine bone and platelet-rich fibrin (PRF) with a collagen membrane were used to graft the extraction sockets, and the membranes were left exposed to the oral cavity with a secondary soft tissue healing. The outcome variables were as follows: width of keratinized mucosa, facial soft tissue levels, clinical bone changes (measured with a clinical splint), implant and prosthesis failures, and peri-implant marginal bone changes. All treated sites allowed the placement of implants; the width of keratinized mucosa at the mid-facial aspect showed an increase of 2.3 mm 5 months after the grafting procedure, and its value was 3.2 ± 0.6 mm at 1-year follow-up. The mean values of the facial soft tissue level indicated an increase over time. The bone level showed an improvement of 0.8 ± 0.1 mm and 0.7 ± 0.1 mm at mesial and distal sites, respectively, when compared to the baseline measurements. Finally, in the palatal area, no bone changes were observed. No implant failed during the entire observation period. Findings from this study showed that xenograft and PRF, used for ridge preservation of the extraction sockets with buccal bone plate dehiscence in the esthetic zone, can be considered effective in repairing bone defects before implant placement. The secondary soft tissue healing over the grafted sockets did not compromise bone formation; moreover, the soft tissue level and the width of keratinized gingiva showed a significant improvement over time. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Immediate implant placement into posterior sockets with or without buccal bone dehiscence defects: A retrospective cohort study.

    PubMed

    Hu, Chen; Gong, Ting; Lin, Weimin; Yuan, Quan; Man, Yi

    2017-10-01

    To evaluate bone reconstruction and soft tissue reactions at immediate implants placed into intact sockets and those with buccal bone dehiscence defects. Fifty-nine internal connection implants from four different manufacturers were immediately placed in intact sockets(non-dehiscence group, n=40), and in alveoli with buccal bone dehiscence defects: 1) Group 1(n= N10), the defect depth measured 3-5 mm from the gingival margin. 2) Group 2(n=9), the depth ranged from 5mm to 7mm. The surrounding bony voids were grafted with deproteinized bovine bone mineral (DBBM) particles. Cone beam computed tomography(CBCT) was performed immediately after surgery (T1), and at 6 months later(T2). Radiographs were taken at prosthesis placement and one year postloading(T3). Soft tissue parameters were measured at baseline (T0), prosthesis placement and T3. No implants were lost during the observation period. For the dehiscence groups, the buccal bone plates were radiographically reconstructed to comparable horizontal and vertical bone volumes compared with the non-dehiscence group. Marginal bone loss occurred between the time of final restoration and 1-year postloading was not statistically different(P=0.732) between groups. Soft tissue parameters did not reveal inferior results for the dehiscence groups. Within the limitations of this study, flapless implant placement into compromised sockets in combination with DBBM grafting may be a viable technique to reconstitute the defected buccal bone plates due to space maintenance and primary socket closure provided by healing abutments and bone grafts. Immediate implants and DBBM grafting without using membranes may be indicated for sockets with buccal bone defects. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Porous and nonporous orbital implants for treating the anophthalmic socket: A meta-analysis of case series studies.

    PubMed

    Schellini, Silvana; Jorge, Eliane; Sousa, Roberta; Burroughs, John; El-Dib, Regina

    2016-01-01

    To assess the efficacy and safety of porous and nonporous implants for management of the anophthalmic socket. Case series meta-analysis was conducted with no language restriction, including studies from: PUBMED, EMBASE and LILACS. Study eligibility criteria were case series design with more than 20 cases reported, use of porous and/or nonporous orbital implants, anophthalmic socket and, treatment success defined as no implant exposure or extrusion. Complications rates from each included study were quantified. Proportional meta-analysis was performed on both outcomes with a random-effects model and the 95% confidential intervals were calculated. A total of 35 case series studies with a total of 3,805 patients were included in the meta-analysis. There are no studies comparing porous and nonporous implants in the anophthalmic socket treatment. There was no statistically significant difference between porous polyethylene (PP) and hydroxyapatite (HA) on implant exposure: 0.026 (0.012-0.045) vs 0.054 (0.041-0.070), respectively and, neither on implant extrusion: 0.0042 (0.0008-0.010) vs. 0.018 (0.004-0.042), respectively. However, there was a significant difference supporting the use of PP when compared to bioceramic implant: 0.026 (0.012 -0.045) vs. 0.12 (0.06-0.20), respectively, on implant exposure. PP implants showed lower chance of exposure than bioceramic implant for anophthalmic socket reconstruction, although we cannot rule out the possibility of heterogeneity bias due to the nature and level of evidence of the included studies. Clinical trials are necessary to expand the knowledge of porous and nonporous orbital implants in the anophthalmic socket management.

  8. Selection Process for New Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  9. Design Guidance for New Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  10. Selection Process for Replacement Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  11. Design Guidance for Replacement Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  12. Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    PubMed

    Al-Fakih, Ebrahim; Arifin, Nooranida; Pirouzi, Gholamhossein; Mahamd Adikan, Faisal Rafiq; Shasmin, Hanie Nadia; Abu Osman, Noor Azuan

    2017-08-01

    This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  13. Modeling the interactions between a prosthetic socket, polyurethane liners and the residual limb in transtibial amputees using non-linear finite element analysis.

    PubMed

    Simpson, G; Fisher, C; Wright, D K

    2001-01-01

    Continuing earlier studies into the relationship between the residual limb, liner and socket in transtibial amputees, we describe a geometrically accurate non-linear model simulating the donning of a liner and then a socket. The socket is rigid and rectified and the liner is a polyurethane geltype which is accurately described using non-linear (Mooney-Rivlin) material properties. The soft tissue of the residual limb is modelled as homogeneous, non-linear and hyperelastic and the bone structure within the residual limb is taken as rigid. The work gives an indication of how the stress induced by the process of donning the rigid socket is redistributed by the liner. Ultimately we hope to understand how the liner design might be modified to reduce discomfort. The ANSYS finite element code, version 5.6 is used.

  14. Load-bearing Characters Analysis of Large Diameter Rock-Socketed Filling Piles Based on Self-Balanced Method

    NASA Astrophysics Data System (ADS)

    tongqing, Wu; liang, Li; xinjian, Liu; Xu, nianchun; Tian, Mao

    2018-03-01

    Self-balanced method is carried out on the large diameter rock-socketed filling piles of high-pile wharf at Inland River, to explore the distribution laws of load-displacement curve, pile internal force, pile tip friction resistance and pile side friction resistance under load force. The results showed that: the tip resistance of S1 and S2 test piles accounted for 53.4% and 53.6% of the pile bearing capacity, respectively, while the total side friction resistance accounted for 46.6% and 46.4% of the pile bearing capacity, respectively; both the pile tip friction resistance and pile side friction resistance can be fully played, and reach to the design requirements. The reasonability of large diameter rock-socketed filling design is verified through test analysis, which can provide basis for the optimization of high-pile wharf structural type, thus reducing the wharf project cost, and also providing reference for the similar large diameter rock-socketed filling piles of high-pile wharf at Inland River.

  15. Clinical and biometrical evaluation of socket preservation using demineralized freeze-dried bone allograft with and without the palatal connective tissue as a biologic membrane.

    PubMed

    Moghaddas, Hamid; Amjadi, Mohammad Reza; Naghsh, Narges

    2012-11-01

    Alveolar ridge preservation following tooth extraction has the ability to maintain the ridge dimensions and allow the implant placement in an ideal position fulfilling both functional and aesthetic results. The aim of this study was to evaluate the efficacy of the palatal connective tissue as a biological membrane for socket preservation with demineralized freeze-dried bone allograft (DFDBA). Twelve extraction sites were treated with DFDBA with (case group) and without (control group) using autogenous palatal connective tissue membrane before placement of implants. Alveolar width and height, amount of keratinized tissue, and gingival level were measured at pre-determined points using a surgical stent at two times, the time of socket preservation surgery. In both groups a decrease in all socket dimensions was found. The average decrease in socket width, height, keratinized tissue, and gingival level in case group was 1.16, 0.72, 3.58, and 1.27 mm, and in control group was 2.08, 0.86, 4.52, and 1.58 mm respectively. Statistical analysis showed that decrease in socket width (P = 0.012), keratinized tissue (P ≤ 0.001), and gingival level (P = 0.031) in case group was significantly lower than that of the control group. Results showed no meaningful difference in socket height changes when compared with case and control groups (P = 0.148). Under the limits of this study, connective tissue membrane could preserve socket width, amount of keratinized tissue, and the gingival level more effectively than DFDBA alone.

  16. Effects of intra-alveolar placement of 0.2% chlorhexidine bioadhesive gel on dry socket incidence and postsurgical pain: a double-blind split-mouth randomized controlled clinical trial.

    PubMed

    Haraji, Afshin; Rakhshan, Vahid; Khamverdi, Naiemeh; Alishahi, Hadiseh Khanzadeh

    2013-01-01

    To assess the effects of intra-alveolar application of chlorhexidine gel on the incidence of alveolar osteitis (dry socket) and the severity of postsurgical pain. A total of 160 impacted mandibular third molars were extracted in 80 patients enrolled in this trial. In each subject, a socket was randomly selected and packed to the crest of the alveolar ridge with a gelatin sponge dressing saturated in 0.2% chlorhexidine gel. The contralateral socket was packed with a dry dressing as the placebo. None of the included patients took antibiotics or analgesics. The occurrence of dry socket and patients' pain levels were assessed at the first and third postoperative days. The data were analyzed using Spearman correlation coefficient, McNemar, Wilcoxon, and chi-square tests. Chlorhexidine gel significantly reduced dry socket incidence from 32.6% to 11.3% (P ≤ .001 [McNemar and chi-square], absolute risk reduction = 21.2%, relative risk reduction = 65.4%, odds ratio = 0.263, relative risk = 0.345). It also significantly relieved postoperative pain on both sides in all the patients (P ≤ .001 [Wilcoxon]) and also in the 54 subjects who did not develop dry socket (P ≤ .001 [Wilcoxon]). Besides decreasing the incidence of dry socket, chlorhexidine gel can reduce postsurgical pain in patients with and without dry socket.

  17. Lobster eye as a collector for water window microscopy

    NASA Astrophysics Data System (ADS)

    Pina, L.; Maršíková, V.; Inneman, A.; Nawaz, M. F.; Jančárek, A.; Havlíková, R.

    2017-08-01

    Imaging in EUV, SXR and XR spectral bands of radiation is of increasing interest. Material science, biology and hot plasma are examples of relevant fast developing areas. Applications include spectroscopy, astrophysics, Soft X-ray Ray metrology, Water Window microscopy, radiography and tomography. Especially Water Window imaging has still not fully recognized potential in biology and medicine microscopy applications. Theoretical study and design of Lobster Eye (LE) optics as a collector for water window (WW) microscopy and comparison with a similar size ellipsoidal mirror condensor are presented.

  18. X-ray beamsplitter

    DOEpatents

    Ceglio, Natale M.; Stearns, Daniel S.; Hawryluk, Andrew M.; Barbee, Jr., Troy W.

    1989-01-01

    An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5-50 pairs of alternate Mo/Si layers with a period of 20-250 A. The support membrane is 10-200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window.

  19. 53 W average power few-cycle fiber laser system generating soft x rays up to the water window.

    PubMed

    Rothhardt, Jan; Hädrich, Steffen; Klenke, Arno; Demmler, Stefan; Hoffmann, Armin; Gotschall, Thomas; Eidam, Tino; Krebs, Manuel; Limpert, Jens; Tünnermann, Andreas

    2014-09-01

    We report on a few-cycle laser system delivering sub-8-fs pulses with 353 μJ pulse energy and 25 GW of peak power at up to 150 kHz repetition rate. The corresponding average output power is as high as 53 W, which represents the highest average power obtained from any few-cycle laser architecture so far. The combination of both high average and high peak power provides unique opportunities for applications. We demonstrate high harmonic generation up to the water window and record-high photon flux in the soft x-ray spectral region. This tabletop source of high-photon flux soft x rays will, for example, enable coherent diffractive imaging with sub-10-nm resolution in the near future.

  20. Rheoceptive mediators of graviperception in a water flea: Morphological implications of antennal-socket setae in daphnia magna

    NASA Technical Reports Server (NTRS)

    Meyers, D. G.

    1984-01-01

    Aquatic microcrustaceans of the genus Daphnia are known to orient to light during the day. At night, in the absence of visual cues, daphnids were suspected of maintaining equilibrium by monitoring the direction of gravity through their swimming antennae. Recent investigations using simulated, weightlessness conditions coupled with absence of illumination revealed hair like structures or setae on the basal, articulating socket of the antennae that, when surgically removed, resulted in disorientation. Given the simulated weightlessness or neutrally buoyant condition that eliminated sinking of the normally negatively buoyant Daphnia, it was proposed that the antennal socket setae function as rheoceptors stimulated by the upward rush of water currents during gravity induced, sinking phase of daphnid swimming movements. This rheoceptively mediated, gravity perception hypothesis is further supported by morphological investigations. Scanning electron micrographs indicate that antennal socket setae are anatomically similar to proprioceptors used by higher crustaceans to monitor gravitational direction.

  1. Circuit reliability boosted by soldering pins of disconnect plugs to sockets

    NASA Technical Reports Server (NTRS)

    Pierce, W. B.

    1964-01-01

    Where disconnect pins must be used for wiring and testing a circuit, improved system reliability is obtained by making a permanent joint between pins and sockets of the disconnect plug. After the circuit has been tested, contact points may be fused through soldering, brazing, or welding.

  2. Implementing TCP/IP and a socket interface as a server in a message-passing operating system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hipp, E.; Wiltzius, D.

    1990-03-01

    The UNICOS 4.3BSD network code and socket transport interface are the basis of an explicit network server for NLTSS, a message passing operating system on the Cray YMP. A BSD socket user library provides access to the network server using an RPC mechanism. The advantages of this server methodology are its modularity and extensibility to migrate to future protocol suites (e.g. OSI) and transport interfaces. In addition, the network server is implemented in an explicit multi-tasking environment to take advantage of the Cray YMP multi-processor platform. 19 refs., 5 figs.

  3. X-ray beamsplitter

    DOEpatents

    Ceglio, N.M.; Stearns, D.G.; Hawryluk, A.M.; Barbee, T.W. Jr.

    1987-08-07

    An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5--50 pairs of alternate Mo/Si layers with a period of 20--250 A. The support membrane is 10--200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window. 6 figs.

  4. Is ridge preservation/augmentation at periodontally compromised extraction sockets safe? A retrospective study.

    PubMed

    Kim, Jung-Ju; Ben Amara, Heithem; Schwarz, Frank; Kim, Hae-Young; Lee, Jung-Won; Wikesjö, Ulf M E; Koo, Ki-Tae

    2017-10-01

    This study aimed to evaluate the safety of ridge preservation/augmentation procedures when performed at compromised extraction sockets. Patients subject to ridge preservation/augmentation at periodontally compromised sockets at Seoul National University Dental Hospital (SNUDH) were evaluated in a chart review. Tooth extractions due to acute infection were not included in our study as chronically formed lesions are the only lesions that can be detected from radiographic images. If inflammatory symptoms persisted following ridge preservation/augmentation and antimicrobial and anti-inflammatory therapy, the patient was categorized as a re-infection case and implanted biomaterial removed. Of 10,060 patients subject to tooth extractions at SNUDH, 2011 through 2015, 297 cases meeting inclusion criteria were reviewed. The severity and type of lesions were not specific because extracting data was only done by radiographic images and chart records. The review identified eight patients exhibiting inflammatory symptoms that required additional antimicrobial and anti-inflammatory therapy. Within this group, re-infection occurred in two patients requiring biomaterials removal. The final safety rate for the ridge preservation/augmentation was 99.3%. None of the demographic factors, systemic conditions or choice of biomaterial affected the safety of ridge preservation/augmentation. Alveolar ridge preservation/augmentation at periodontally compromised sockets appears safe following thorough removal of infectious source. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. A combined kinematic and kinetic analysis at the residuum/socket interface of a knee-disarticulation amputee.

    PubMed

    Tang, Jinghua; McGrath, Michael; Hale, Nick; Jiang, Liudi; Bader, Dan; Laszczak, Piotr; Moser, David; Zahedi, Saeed

    2017-11-01

    The bespoke interface between a lower limb residuum and a prosthetic socket is critical for an amputee's comfort and overall rehabilitation outcomes. Analysis of interface kinematics and kinetics is important to gain full understanding of the interface biomechanics, which could aid clinical socket fit, rehabilitation and amputee care. This pilot study aims to investigate the dynamic correlation between kinematic movement and kinetic stresses at the interface during walking tests on different terrains. One male, knee disarticulation amputee participated in the study. He was asked to walk on both a level surface and a 5° ramped surface. The movement between the residuum and the socket was evaluated by the angular and axial couplings, based on the outputs from a 3D motion capture system. The corresponding kinetic stresses at anterior-proximal (AP), posterior-proximal (PP) and anterior-distal (AD) locations of the residuum were measured, using individual stress sensors. Approximately 8° of angular coupling and up to 32 mm of axial coupling were measured when walking on different terrains. The direction of the angular coupling shows strong correlation with the pressure difference between the PP and AP sensors. Higher pressure was obtained at the PP location than the AP location during stance phase, associated with the direction of the angular coupling. A strong correlation between axial coupling length, L, and longitudinal shear was also evident at the PP and AD locations i.e. the shortening of L corresponds to the increase of shear in the proximal direction. Although different terrains did not affect these correlations in principle, interface kinematic and kinetic values suggested that gait changes can induce modifications to the interface biomechanics. It is envisaged that the reported techniques could be potentially used to provide combined kinematics and kinetics for the understanding of biomechanics at the residuum/socket interface, which may play an important

  6. Lateral capacity of rock sockets in limestone under cyclic and repeated loading.

    DOT National Transportation Integrated Search

    2010-08-01

    This report contains the results from full scale lateral load testing of two short rock socketed shafts in : limestone, and the development of recommendations for p-y analysis using those results. Two short shafts 42 : inches in diameter were constru...

  7. [Development of cloud chamber having thin-film entrance windows and proposal of practical training for beginners using X-ray equipment and unsealed radioactive material].

    PubMed

    Konishi, Yuki; Hayashi, Hiroaki; Takegami, Kazuki; Fukuda, Ikuma; Ueno, Junji

    2014-01-01

    A cloud chamber is a detector that can visualize the tracks of charged particles. Hayashi, et al. suggested a visualization experiment in which X-rays generated by diagnostic X-ray equipment were directed into a cloud chamber; however, there was a problem in that the wall of the cloud chamber scattered the incoming X-rays. In this study, we developed a new cloud chamber with entrance windows. Because these windows are made of thin film, we were able to direct the X-rays through them without contamination by scattered X-rays from the cloud chamber wall. We have newly proposed an experiment in which beta-particles emitted from radioisotopes are directed into a cloud chamber. We place shielding material in the cloud chamber and visualize the various shielding effects seen with the material positioned in different ways. During the experiment, electrons scattered in the air were measured quantitatively using GM counters. We explained the physical phenomena in the cloud chamber using Monte Carlo simulation code EGS5. Because electrons follow a tortuous path in air, the shielding material must be placed appropriately to be able to effectively block their emissions. Visualization of the tracks of charged particles in this experiment proved effective for instructing not only trainee radiological technologists but also different types of healthcare professionals.

  8. Window Operator Types | Efficient Windows Collaborative

    Science.gov Websites

    Types Casement Casement Casement windows are hinged at the sides. Hinged windows such as casements operating types to consider. Traditional operable window types include the projected or hinged types such as casement, awning, and hopper, and the sliding types such as double- and single-hung and horizontal sliding

  9. Ankle Fusion Combined With Calcaneal Sliding Osteotomy for Severe Arthritic Ball and Socket Ankle Deformity.

    PubMed

    Cho, Byung-Ki; Park, Kyoung-Jin; Choi, Seung-Myung; Kang, Sang-Woo; Lee, Hyung-Ki

    2016-12-01

    Although a ball and socket ankle deformity is usually congenital and asymptomatic, abnormal inversion and eversion mobility can result in recurrent ankle sprain and osteoarthritis. This retrospective study was performed to evaluate the clinical and radiologic outcomes of ankle fusion combined with calcaneal sliding osteotomy for severe arthritic ball and socket ankle deformity. Fourteen patients with severe arthritic ball and socket ankle deformity were followed for more than 3 years after operation. The clinical evaluation consisted of American Orthopaedic Foot & Ankle Society (AOFAS) score, Foot and Ankle Ability Measure (FAAM), visual analog scale (VAS) for pain, and subjective satisfaction score. The period to fusion and union of osteotomy, the change of hindfoot alignment angle, and complications were evaluated radiologically. AOFAS and FAAM scores were significantly improved from an average of 37.4 and 34.5 points to 74.6 and 78.5 points, respectively. VAS for pain with walking over 20 minutes was significantly improved from an average of 8.4 points to 1.9 points. The average satisfaction score of patients was 88.9 points. The difference in heel alignment angle (compared to contralateral side) was significantly improved from an average of 34.8 to 5.4 degrees. There were 2 cases of progressive arthritis in an adjacent joint and 1 case of failed fusion. Ankle fusion combined with calcaneal sliding osteotomy can be an effective operative option for ball and socket ankle deformity with advanced arthritis. In spite of increased complication rate, reliable pain relief, and restoration of gait ability through correcting hindfoot malalignment could improve the quality of life. Level IV, retrospective case series. © The Author(s) 2016.

  10. Bone physiology in human grafted and non-grafted extraction sockets--an immunohistochemical study.

    PubMed

    Nahles, Susanne; Nack, Claudia; Gratecap, Kerrin; Lage, Hermann; Nelson, John J; Nelson, Katja

    2013-07-01

    The aim of the present immunohistological investigation was to define and compare the osteogenic potential with the vascularization of the provisional matrix in grafted and ungrafted extraction sockets after 4 and 12 weeks of healing. A total of 33 Patients (15 women, 18 men) with 65 extraction sites with a mean age of 54.4 years (30-73 years) participated in this study. After tooth extraction, the sockets were augmented with Bio-Oss collagen or non-augmented. At implant placement after 4 or 12 weeks bone biopsies were obtained. Within the specimens the osteogenic and endothelial potential of mesenchymal cells was analyzed in the provisional matrix using immunohistochemical analysis with three monoclonal antibodies Cbfa1/Runx2, Osteocalcin (OC), and CD31. Statistical analysis was performed using Mann-Whitney U-test, Spearman's rank-order correlation coefficient, and the two-factorial analysis for repeated measurements. Of the 65 extraction sockets, 25 (13 non-augmented, 12 augmented) sites after 4 weeks healing time and 40 (19 non-augmented, 21 augmented) sites after 12 weeks healing time were involved in the study. No signs of acute or chronic inflammation were noted in any specimens. After 4 weeks, a median amount of 56% (10-85%) of Cbfa1 positive cells and a median amount of cells expressing OC of 21% (5-42%) were measured. A median CD31 score of 5 was observed. After 12 weeks, a median amount of 61% (19-90%) positive cells expressed by Cbfa1/Runx2 staining a median amount of OC positive cells of 9% (2-17%) was measured. The results at 12 weeks revealed a median score of CD31 positive cells of 3. Osteoblastic activity in the provisional matrix was highest after 4 weeks of healing period. The active zone of bone formation is found in the apical region of the extraction socket during the early healing phase, shifting to the coronal region after 12 weeks. A peak of osteoblast activity within the first weeks is followed by a reduction in mature

  11. Immediate Loading of Tapered Implants Placed in Postextraction Sockets and Healed Sites.

    PubMed

    Han, Chang-Hun; Mangano, Francesco; Mortellaro, Carmen; Park, Kwang-Bum

    2016-07-01

    The aim of the present study was to compare the survival, stability, and complications of immediately loaded implants placed in postextraction sockets and healed sites. Over a 2-year period, all patients presenting with partial or complete edentulism of the maxilla and/or mandible (healed site group, at least 4 months of healing after tooth extraction) or in need of replacement of nonrecoverable failing teeth (postextraction group) were considered for inclusion in this study. Tapered implants featuring a nanostructured calcium-incorporated surface were placed and loaded immediately. The prosthetic restorations comprised single crowns, fixed partial dentures, and fixed full arches. Primary outcomes were implant survival, stability, and complications. Implant stability was assessed at placement and at each follow-up evaluation (1 week, 3 months, and 1 year after placement): implants with an insertion torque (IT) <45 N·cm and/or with an implant stability quotient (ISQ) <70 were considered failed for immediate loading. A statistical analysis was performed. Thirty implants were placed in postextraction sockets of 17 patients, and 32 implants were placed in healed sites of 22 patients. There were no statistically significant differences in ISQ values between the 2 groups, at each assessment. In total, 60 implants (96.8%) had an IT ≥45 and an ISQ ≥70 at placement and at each follow-up control: all these implants were successfully loaded. Only 2 implants (1 in a postextraction socket and 1 in a healed site, 3.2%) could not achieve an IT ≥45 N·cm and/or an ISQ ≥70 at placement or over time: accordingly, these were considered failed for stability, as they could not be subjected to immediate loading. One of these 2 implants, in a healed site of a posterior maxilla, had to be removed, yielding an overall 1-year implant survival rate of 98.4%. No complications were reported. No significant differences were reported between the 2 groups with respect to implant

  12. Reconstruction of severe anophthalmic orbits and atresic eye sockets after enucleation and irradiation of retinoblastoma by vascular anastomosed free dorsalis pedis flaps' transplantation.

    PubMed

    Bi, Xiaoping; Fan, Xianqun; Zhou, Huifang; Shi, Wodong; Xiao, Caiwen; Lin, Min; Li, Zhenkang

    2011-05-01

    Retinoblastoma is a common malignant intraocular tumor in childhood, and most patients require enucleation or exenteration even with irradiation. Severe anophthalmic orbits and atresic eye sockets are not rare. We conducted a retrospective study to evaluate the results of surgical management of reconstruction of severe anophthalmic orbits and atresic eye sockets with vascular anastomosed free dorsalis pedis flap transplantation. There were 5 patients (5 eyes) who underwent reconstructive surgery of severe anophthalmic orbits and atresic eye sockets after enucleation and irradiation of retinoblastoma in our hospital during the 3 years. All patients had enucleation and irradiation immediately after the retinoblastoma was diagnosed and had never worn artificial eyes because of the atresic eye sockets. Vascular anastomosed free dorsalis pedis flaps, whose dimensions were typically 6.5 × 5.5 cm(2), were transplanted to reconstruct the severe anophthalmic orbits and atresic eye sockets. The donor sites were covered by free abdominal skin flaps. All the vascular anastomosed free dorsalis pedis flaps were valid after more than 6 months of follow-up. And then all the 5 patients underwent secondary autogenous dermal fat implantation to augment the supraorbital area depression. After the 2-stage reconstruction surgery, the dimensions of the eye sockets were adequate, and all patients were able to wear their prosthesis and had a satisfactory cosmetic result. Implantation of alloplastic materials is not recommended because of insufficient blood supply of the irradiated orbital area.

  13. Update of GRASP/Ada reverse engineering tools for Ada

    NASA Technical Reports Server (NTRS)

    Cross, James H., II

    1992-01-01

    The GRASP/Ada project (Graphical Representations of Algorithms, Structures, and Processes for Ada) has successfully created and prototyped a new algorithmic level graphical representation of Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and, as a result, improve reliability and reduce costs. The emphasis was on the automatic generation of the CSD from Ada PDL or source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional prettyprinted Ada source code. In Phase 1 of the GRASP/Ada project, the CSD graphical constructs were created and applied manually to several small Ada programs. A prototype (Version 1) was designed and implemented using FLEX and BISON running under VMS on a VAS 11-780. In Phase 2, the prototype was improved and ported to the Sun 4 platform under UNIX. A user interface was designed and partially implemented using the HP widget toolkit and the X Windows System. In Phase 3, the user interface was extensively reworked using the Athena widget toolkit and X Windows. The prototype was applied successfully to numerous Ada programs ranging in size from several hundred to several thousand lines of source code. Following Phase 3, the prototype was evaluated by software engineering students at Auburn University and then updated with significant enhancements to the user interface including editing capabilities. Version 3.2 of the prototype was prepared for limited distribution to facilitate further evaluation. The current prototype provides the capability for the user to generate CSD's from Ada PDL or source code in a reverse engineering as well as forward engineering mode with a level of flexibility suitable for practical application.

  14. Development of a socketed foundation for the Midwest Weak Post (MWP) v1.

    DOT National Transportation Integrated Search

    2014-07-01

    A socketed foundation was designed and evaluated for use with the Midwest Weak Post (MWP), Version 1. : Dynamic component testing was conducted on five different design configurations with varying embedment : depths, steel reinforcement, and soil con...

  15. Control and Measurement of an Xmon with the Quantum Socket

    NASA Astrophysics Data System (ADS)

    McConkey, T. G.; Bejanin, J. H.; Earnest, C. T.; McRae, C. R. H.; Rinehart, J. R.; Weides, M.; Mariantoni, M.

    The implementation of superconducting quantum processors is rapidly reaching scalability limitations. Extensible electronics and wiring solutions for superconducting quantum bits (qubits) are among the most imminent issues to be tackled. The necessity to substitute planar electrical interconnects (e.g., wire bonds) with three-dimensional wires is emerging as a fundamental pillar towards scalability. In a previous work, we have shown that three-dimensional wires housed in a suitable package, named the quantum socket, can be utilized to measure high-quality superconducting resonators. In this work, we set out to test the quantum socket with actual superconducting qubits to verify its suitability as a wiring solution in the development of an extensible quantum computing architecture. To this end, we have designed and fabricated a series of Xmon qubits. The qubits range in frequency from about 6 to 7 GHz with anharmonicity of 200 MHz and can be tuned by means of Z pulses. Controlling tunable Xmons will allow us to verify whether the three-dimensional wires contact resistance is low enough for qubit operation. Qubit T1 and T2 times and single qubit gate fidelities are compared against current standards in the field.

  16. To assess the efficacy of socket plug technique using platelet rich fibrin with or without the use of bone substitute in alveolar ridge preservation: a prospective randomised controlled study.

    PubMed

    Girish Kumar, N; Chaudhary, Rupanzal; Kumar, Ish; Arora, Srimathy S; Kumar, Nilesh; Singh, Hem

    2018-06-01

    The purpose of this study is to evaluate the efficacy of Platelet Rich Fibrin (PRF) as a socket plug with or without use of Plaster of Paris (POP) as bone substitute to preserve the alveolar ridge post-extraction. A prospective randomised single blind controlled study, was conducted for 18 months from November 2014 to May 2016 on 48 patients requiring extraction. All teeth were extracted atraumatically using periotomes and luxators without raising mucoperiosteal flap. Sockets were randomly allotted to groups A, B and C. Group A sockets were chosen as control, where figure of eight suture was placed. In group B sockets, PRF obtained by centrifugation was used as a socket plug and stabilised with figure of eight suture. Group C sockets were filled with POP and then covered with PRF. The socket was then closed with a figure of eight suture. Patients were informed of need for 6 months follow-up. Ninety sockets in 48 patients were subjected to our study. We found that results in the sockets where we have grafted POP showed better ridge preservation and post-operative comfort even though the difference in ridge resorption between the three groups was not statistically significant. Powered by Editorial Manager® and ProduXion Manager® from the Aries Systems Corporation. Atraumatic extraction may minimise the post-operative pain and discomfort to patient as well as the post-extraction alveolar height and width changes. The use of PRF and/or bone substitute even though clinically contributes to better post-operative healing and minimal loss of alveolar width and height, the values were not statistically significant.

  17. Integral window/photon beam position monitor and beam flux detectors for x-ray beams

    DOEpatents

    Shu, Deming; Kuzay, Tuncer M.

    1995-01-01

    A monitor/detector assembly in a synchrotron for either monitoring the position of a photon beam or detecting beam flux may additionally function as a vacuum barrier between the front end and downstream segment of the beamline in the synchrotron. A base flange of the monitor/detector assembly is formed of oxygen free copper with a central opening covered by a window foil that is fused thereon. The window foil is made of man-made materials, such as chemical vapor deposition diamond or cubic boron nitrate and in certain configurations includes a central opening through which the beams are transmitted. Sensors of low atomic number materials, such as aluminum or beryllium, are laid on the window foil. The configuration of the sensors on the window foil may be varied depending on the function to be performed. A contact plate of insulating material, such as aluminum oxide, is secured to the base flange and is thereby clamped against the sensor on the window foil. The sensor is coupled to external electronic signal processing devices via a gold or silver lead printed onto the contact plate and a copper post screw or alternatively via a copper screw and a copper spring that can be inserted through the contact plate and coupled to the sensors. In an alternate embodiment of the monitor/detector assembly, the sensors are sandwiched between the window foil of chemical vapor deposition diamond or cubic boron nitrate and a front foil made of similar material.

  18. Socket preservation using demineralized freezed dried bone allograft with and without plasma rich in growth factor: A canine study

    PubMed Central

    Mogharehabed, Ahmad; Birang, Reza; Torabinia, Nakisa; Nasiri, Saman; Behfarnia, Parichehr

    2014-01-01

    Background: The accelerating effect of plasma rich in growth factors (PRGFs) in the healing of extraction sockets has been demonstrated by some studies. The aim of the present study was to histologically and histomorphometrically evaluate whether bone formation would increase by the combined use of PRGF and demineralized freeze-dried bone allograft (DFDBA). Materials and Methods: In four female dogs, the distal root of the second, third and fourth lower premolars were extracted bilaterally and the mesial roots were preserved. The extraction sockets were randomly divided into DFDBA + PRGF, DFDBA + saline or control groups. Two dogs were sacrificed after 2 weeks and two dogs were sacrificed after 6 weeks. The extraction sockets were evaluated from both histological and histomorphometrical aspects. The data were analyzed by Mann-Whitney followed by Kruskal-Wallis tests using the Statistical Package for the Social Sciences version 20 (SPSS Inc., Chicago, IL, USA). Significant levels were set at 0.05. Results: The least decrease in socket height was observed in the DFDBA + PRGF group (0.73 ± 0.42 mm). The least decrease in the coronal portion was observed in the DFDBA + PRGF group (1.38 ± 1.35 mm²). The least decrease in the middle surface was observed in the DFDBA group (0.61 ± 0.80 mm²). The least decrease in the apical portion was observed in the DFDBA group (0.34 ± 0.39 mm²). Conclusion: The present study showed better socket preservation subsequent to the application of DFDBA and PRGF combination in comparison with the two other groups. However, the difference was not statistically significant. PMID:25225559

  19. Provision of an X-environment using the HEPiX-X11 scripts

    NASA Astrophysics Data System (ADS)

    Jones, R. W. L.; Cons, L.; Taddei, A.

    1997-02-01

    At CERN, we have created a user X11 environment within the HEPiX framework. Customisation is possible at the HEPiX, site, cluster, machine, group and user level, in order of increasing priority. The management of the X11 session is divorced from the window management. FVWM is the default window manager, being light on system resources while providing most of the desired functionality. The assembly of a correctly ordered. fvwmrc is done automatically by the scripts, with customisation allowed at all of the above levels. Two tools are provided to query aspects of that environment. These may be used both at the start of the X-session or when commencing any application. The first is guesskbd, a tool to identify the user's keyboard. A second, provides useful information about a given display.

  20. Effects of green tea and bisphosphonate association on dental socket repair of rats.

    PubMed

    Mada, Edson Yoshihiro; Santos, Alana Claro Cunha; Fonseca, Angelica Cristina; Biguetti, Claudia Cristina; Neves, Fernando Tozze Alves; Saraiva, Patrícia Pinto; Matsumoto, Mariza Akemi

    2017-03-01

    To evaluate the effects of green tea intake and zoledronic acid intravenous therapy on teeth socket repair. Sixty male albinus Wistar rats were divided into 4 groups: C-Control, intravenous (IV) 0.9% saline solution (SS), GT-1% green tea in drinking water and IV SS, BP-IV zoledronic acid (BP), and BP+GT-IV BP and 1% green tea. 0.035mg/kg of BP was administered every two weeks. After ten weeks, right upper molars were extracted and the green tea started to be offered for GT and BP+GT. After 7, 14, and 28days the animals were euthanized. Histopathology analysis revealed lack of socket repair in BP and BP+GT groups, which presented significant increased number of polimorphonuclear leukocytes at day 28, in comparison with C (p<0.05). No significant differences were detected between C and the experimental groups at the same period (p<0.05) when considering mononuclear leukocytes. Immunolabeling revealed that the association of BP and GT caused a slight disturbance in OPG/RANKL system and retarded Runx-2 labeling. Although strong TRAP labeling was observed, most of the positive cells in BP and BP+GT groups were not located on bone surface. Socket healing of rats treated with BP and regular drinking green tea presented no relevant differences in comparison to those treated with BP alone. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Normalization of load and clearance effects in ball-in-socket-like replacements.

    PubMed

    Ciavarella, M; Strozzi, A; Baldini, A; Giacopini, M

    2007-08-01

    A normalizing loading parameter useful in summarising the mechanical response of plane pin-in-plate-like contacts is extended to axisymmetric ball-in-socket-like contacts. An example addressing a compliant layered artificial hip joint is presented, and the usefulness of the normalizing loading parameter is evidenced.

  2. Ball and socket nanostructures: New supramolecular chemistry based on cyclotriveratrylene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steed, J.W.; Junk, P.C.; Atwood, J.L.

    1994-11-02

    This paper outlines new vistas for the inclusion chemistry of hosts based upon the cyclotriveratrylene motif. A simple method of retrieving pure fullerenes from fullerite without the use of chromatographic techniques has been outlined, and a new class of ball and socket-type inclusion species has been realized by simple modification of either host or guest electronic and steric properties. 14 refs., 2 figs.

  3. A sealable ultrathin window sample cell for the study of liquids by means of soft X-ray spectroscopy

    NASA Astrophysics Data System (ADS)

    Grötzsch, D.; Streeck, C.; Nietzold, C.; Malzer, W.; Mantouvalou, I.; Nutsch, A.; Dietrich, P.; Unger, W.; Beckhoff, B.; Kanngießer, B.

    2017-12-01

    A new sample cell concept for the analysis of liquids or solid-liquid interfaces using soft X-ray spectroscopy is presented, which enables the complete sealing of the cell as well as the transport into vacuum via, for example, a load-lock system. The cell uses pressure monitoring and active as well as passive pressure regulation systems, thereby facilitating the full control over the pressure during filling, sealing, evacuation, and measurement. The cell design and sample preparation as well as the crucial sealing procedure are explained in detail. As a first proof-of-principle experiment, successful nitrogen K-edge fluorescence yield near-edge X-ray absorption fine structure experiments of a biomolecular solution are presented. For this purpose, it is shown that the careful evaluation of all involved parameters, such as window type or photon flux, is desirable for optimizing the experimental result.

  4. IDG - INTERACTIVE DIF GENERATOR

    NASA Technical Reports Server (NTRS)

    Preheim, L. E.

    1994-01-01

    The Interactive DIF Generator (IDG) utility is a tool used to generate and manipulate Directory Interchange Format files (DIF). Its purpose as a specialized text editor is to create and update DIF files which can be sent to NASA's Master Directory, also referred to as the International Global Change Directory at Goddard. Many government and university data systems use the Master Directory to advertise the availability of research data. The IDG interface consists of a set of four windows: (1) the IDG main window; (2) a text editing window; (3) a text formatting and validation window; and (4) a file viewing window. The IDG main window starts up the other windows and contains a list of valid keywords. The keywords are loaded from a user-designated file and selected keywords can be copied into any active editing window. Once activated, the editing window designates the file to be edited. Upon switching from the editing window to the formatting and validation window, the user has options for making simple changes to one or more files such as inserting tabs, aligning fields, and indenting groups. The viewing window is a scrollable read-only window that allows fast viewing of any text file. IDG is an interactive tool and requires a mouse or a trackball to operate. IDG uses the X Window System to build and manage its interactive forms, and also uses the Motif widget set and runs under Sun UNIX. IDG is written in C-language for Sun computers running SunOS. This package requires the X Window System, Version 11 Revision 4, with OSF/Motif 1.1. IDG requires 1.8Mb of hard disk space. The standard distribution medium for IDG is a .25 inch streaming magnetic tape cartridge in UNIX tar format. It is also available on a 3.5 inch diskette in UNIX tar format. The program was developed in 1991 and is a copyrighted work with all copyright vested in NASA. SunOS is a trademark of Sun Microsystems, Inc. X Window System is a trademark of Massachusetts Institute of Technology. OSF/Motif is a

  5. Sojourner Rover View of Sockets and Pebbles

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Well-rounded objects, like the ones in this image, were not seen at the Viking sites. These are thought to be pebbles liberated from sedimentary rocks composed of cemented silts, sands and rounded fragments; such rocks are called conglomerates. The 'sockets' could be the former sites of such pebbles.

    NOTE: original caption as published in Science Magazine

    Mars Pathfinder is the second in NASA's Discovery program of low-cost spacecraft with highly focused science goals. The Jet Propulsion Laboratory, Pasadena, CA, developed and manages the Mars Pathfinder mission for NASA's Office of Space Science, Washington, D.C. JPL is a division of the California Institute of Technology (Caltech).

  6. A Novel Procedure for the Immediate Reconstruction of Severely Resorbed Alveolar Sockets for Advanced Periodontal Disease.

    PubMed

    Aimetti, Mario; Manavella, Valeria; Cricenti, Luca; Romano, Federica

    2017-01-01

    Background. Several clinical techniques and a variety of biomaterials have been introduced over the years in an effort to overcome bone remodeling and resorption after tooth extraction. However, the predictability of these procedures in sockets with severely resorbed buccal/lingual plate due to periodontal disease is still unknown. Case Description. A patient with advanced periodontitis underwent extraction of upper right lateral and central incisors. The central incisor exhibited complete buccal bone plate loss and a 9 mm vertical bone deficiency on its palatal side. The alveolar sockets were filled with collagen sponge and covered with a nonresorbable high-density PTFE membrane. Primary closure was not attained and any rigid scaffold material was not used. Histologic analysis provided evidence of new bone formation. At 12 months a cone-beam computed tomographic scan revealed enough bone volume to insert two conventional dental implants in conjunction with minor horizontal bone augmentation procedures. Clinical Implications. This case report would seem to support the potential of the proposed reconstructive approach in changing the morphology of severely resorbed alveolar sockets, minimizing the need for advanced bone regeneration procedures during implant placement.

  7. A Novel Procedure for the Immediate Reconstruction of Severely Resorbed Alveolar Sockets for Advanced Periodontal Disease

    PubMed Central

    2017-01-01

    Background. Several clinical techniques and a variety of biomaterials have been introduced over the years in an effort to overcome bone remodeling and resorption after tooth extraction. However, the predictability of these procedures in sockets with severely resorbed buccal/lingual plate due to periodontal disease is still unknown. Case Description. A patient with advanced periodontitis underwent extraction of upper right lateral and central incisors. The central incisor exhibited complete buccal bone plate loss and a 9 mm vertical bone deficiency on its palatal side. The alveolar sockets were filled with collagen sponge and covered with a nonresorbable high-density PTFE membrane. Primary closure was not attained and any rigid scaffold material was not used. Histologic analysis provided evidence of new bone formation. At 12 months a cone-beam computed tomographic scan revealed enough bone volume to insert two conventional dental implants in conjunction with minor horizontal bone augmentation procedures. Clinical Implications. This case report would seem to support the potential of the proposed reconstructive approach in changing the morphology of severely resorbed alveolar sockets, minimizing the need for advanced bone regeneration procedures during implant placement. PMID:28250998

  8. Cancellous and cortical bone mineral density around an elastic press-fit socket in total hip arthroplasty.

    PubMed

    Pakvis, Dean F M; Heesterbeek, Petra J C; Severens, Marianne; Spruit, Maarten

    2016-12-01

    Background and purpose - The acetabular component has remained the weakest link in hip arthroplasty for achievement of long-term survival. One of the possible explanatory factors for acetabular failure has been acetabular stress shielding. For this, we investigated the effects of a cementless elastic socket on acetabular bone mineral density (BMD). Patients and methods - During 2008-2009, we performed a single-center prospective cohort trial on 25 patients (mean age 64 (SD 4), 18 females) in whom we implanted a cementless elastic press-fit socket. Using quantitative BMD measurements on CT, we determined the change in BMD surrounding the acetabular component over a 2-year follow-up period. Results - We found a statistically significant decrease in cancellous BMD (-14% to -35%) and a stable level of cortical BMD (5% to -5%) surrounding the elastic press-fit cup during the follow-up period. The main decrease was seen during the first 6 months after implantation. During the second year, cancellous BMD showed a further decrease in the medial and lower acetabular regions. Interpretation - We found no evidence that an elastic press-fit socket would prevent acetabular stress shielding during a 2-year follow-up.

  9. Graphene oxide windows for in situ environmental cell photoelectron spectroscopy.

    PubMed

    Kolmakov, Andrei; Dikin, Dmitriy A; Cote, Laura J; Huang, Jiaxing; Abyaneh, Majid Kazemian; Amati, Matteo; Gregoratti, Luca; Günther, Sebastian; Kiskinova, Maya

    2011-08-28

    The performance of new materials and devices often depends on processes taking place at the interface between an active solid element and the environment (such as air, water or other fluids). Understanding and controlling such interfacial processes require surface-specific spectroscopic information acquired under real-world operating conditions, which can be challenging because standard approaches such as X-ray photoelectron spectroscopy generally require high-vacuum conditions. The state-of-the-art approach to this problem relies on unique and expensive apparatus including electron analysers coupled with sophisticated differentially pumped lenses. Here, we develop a simple environmental cell with graphene oxide windows that are transparent to low-energy electrons (down to 400 eV), and demonstrate the feasibility of X-ray photoelectron spectroscopy measurements on model samples such as gold nanoparticles and aqueous salt solution placed on the back side of a window. These proof-of-principle results show the potential of using graphene oxide, graphene and other emerging ultrathin membrane windows for the fabrication of low-cost, single-use environmental cells compatible with commercial X-ray and Auger microprobes as well as scanning or transmission electron microscopes.

  10. X-38 on B-52 Wing Pylon - View from Observation Window

    NASA Technical Reports Server (NTRS)

    1997-01-01

    A unique, close-up view of the X-38 under the wing of NASA's B-52 mothership prior to launch of the lifting-body research vehicle. The photo was taken from the observation window of the B-52 bomber as it banked in flight. NASA B-52, Tail Number 008, is an air launch carrier aircraft, 'mothership,' as well as a research aircraft platform that has been used on a variety of research projects. The aircraft, a 'B' model built in 1952 and first flown on June 11, 1955, is the oldest B-52 in flying status and has been used on some of the most significant research projects in aerospace history. Some of the significant projects supported by B-52 008 include the X-15, the lifting bodies, HiMAT (highly maneuverable aircraft technology), Pegasus, validation of parachute systems developed for the space shuttle program (solid-rocket-booster recovery system and the orbiter drag chute system), and the X-38. The B-52 served as the launch vehicle on 106 X-15 flights and flew a total of 159 captive-carry and launch missions in support of that program from June 1959 to October 1968. Information gained from the highly successful X-15 program contributed to the Mercury, Gemini, and Apollo human spaceflight programs as well as space shuttle development. Between 1966 and 1975, the B-52 served as the launch aircraft for 127 of the 144 wingless lifting body flights. In the 1970s and 1980s, the B-52 was the launch aircraft for several aircraft at what is now the Dryden Flight Research Center, Edwards, California, to study spin-stall, high-angle-of attack, and maneuvering characteristics. These included the 3/8-scale F-15/spin research vehicle (SRV), the HiMAT (Highly Maneuverable Aircraft Technology) research vehicle, and the DAST (drones for aerodynamic and structural testing). The aircraft supported the development of parachute recovery systems used to recover the space shuttle solid rocket booster casings. It also supported eight orbiter (space shuttle) drag chute tests in 1990. In

  11. Determination of layer ordering using sliding-window Fourier transform of x-ray reflectivity data

    NASA Astrophysics Data System (ADS)

    Smigiel, E.; Knoll, A.; Broll, N.; Cornet, A.

    1998-01-01

    X-ray reflectometry allows the determination of the thickness, density and roughness of thin layers on a substrate from several Angstroms to some hundred nanometres. The thickness is determined by simulation with trial-and-error methods after extracting initial values of the layer thicknesses from the result of a classical Fast Fourier Transform (FFT) of the reflectivity data. However, the order information of the layers is lost during classical FFT. The order of the layers has then to be known a priori. In this paper, it will be shown that the order of the layers can be obtained by a sliding-window Fourier transform, the so-called Gabor representation. This joint time-frequency analysis allows the direct determination of the order of the layers and, therefore, the use of a more appropriate starting model for refining simulations. A simulated and a measured example show the interest of this method.

  12. Window for radiation detectors and the like

    DOEpatents

    Sparks, C.J. Jr.; Ogle, J.C.

    1975-10-28

    An improved x- and gamma-radiation and particle transparent window for the environment-controlling enclosure of various types of radiation and particle detectors is provided by a special graphite foil of a thickness of from about 0.1 to 1 mil. The graphite must have very parallel hexagonal planes with a mosaic spread no greater than 5$sup 0$ to have the necessary strength in thin sections to support one atmosphere or more of pressure. Such graphite is formed by hot- pressing and annealing pyrolytically deposited graphite and thereafter stripping off layers of sufficient thickness to form the window.

  13. Clinical assessment of bone quality of human extraction sockets after conversion with growth factors.

    PubMed

    Ntounis, Athanasios; Geurs, Nico; Vassilopoulos, Philip; Reddy, Michael

    2015-01-01

    The study was conducted to evaluate the effect of mineralized freeze-dried bone allograft (FDBA), alone or in combination with growth factors in extraction sockets, on subjective assessment of bone quality during implant placement. Forty-one patients whose treatment plan involved extraction of anterior or premolar teeth were randomized into four groups: Group 1, collagen plug (control); Group 2, FDBA/β-tricalcium phosphate (β-TCP)/collagen plug; Group 3, FDBA/β-TCP/platelet-rich plasma (PRP)/collagen plug; Group 4, FDBA/β-TCP/recombinant human platelet-derived growth factor BB (rhPDGF-BB)/collagen plug. After 8 weeks of healing, implants were placed. The clinicians assessed bone quality according to the Misch classification. A benchtop calibration exercise test was conducted to evaluate agreement and accuracy of operators in recognizing different bone qualities. Differences were analyzed using one-way analysis of variance (ANOVA) or chi-square tests for continuous and categorical data. Pairwise comparisons were tested using least squares means (LS means). Spearman correlation coefficients were used to evaluate the relationship of bone growth with potential confounders. P < .05 was considered statistically significant. A simple (not weighted) kappa statistic was used to assess the agreement between raters. To assess accuracy in identifying bone quality, a chi-square test was used to compare the percent correct for each rater. The benchtop calibration exercise test demonstrated agreement among clinicians (0.75 and 0.92 between raters 1 and 2 and raters 1 and 3, respectively). Raters were more likely to identify the correct bone quality (P > .05). Inclusion of bone grafting is associated with a shift from D4 quality to D3 quality bone. Inclusion of PRP in bone grafting eliminates the incidence of D4 bone, establishing D3 and D2 quality bone as prevalent (56% vs. 42%, respectively). Inclusion of rhPDGF-BB and β-TCP in combination with the bone grafting has the

  14. Regenerative Needs Following Alveolar Ridge Preservation Procedures in Compromised and Noncompromised Extraction Sockets: A Cone Beam Computed Tomography Study.

    PubMed

    Koutouzis, Theofilos; Lipton, David

    2016-01-01

    The aim of this study was to evaluate the necessity for additional regenerative procedures following healing of compromised and noncompromised extraction sockets with alveolar ridge preservation procedures through the use of virtual implant imaging software. The cohort was comprised of 87 consecutive patients subjected to a single maxillary tooth extraction with an alveolar ridge preservation procedure for subsequent implant placement. Patients were divided into two main groups based on the integrity of the buccal bone plate following teeth extraction. Patients in the compromised socket (CS) group (n = 52) had partial or complete buccal bone plate loss, and patients in the noncompromised socket (NCS) group (n = 35) exhibited no bone loss of their socket walls following tooth extraction. Following 4 to 6 months of healing, all patients had a cone beam computed tomography (CBCT) study. Root-formed implants were placed virtually in an ideal prosthetic position. The number of implants per group and location (anterior, premolar, molar) exhibiting exposed buccal implant surface was calculated. In the CS group, 5 out of 19 anterior implants (26.3%), 4 out of 14 premolar implants (28.5%), and 7 out of 19 molar implants (36.8%) had exposed buccal surfaces. In the NCS group, 4 out of 9 anterior implants (44.4%), 2 out of 9 premolar implants (22.2%), and 4 out of 17 molar implants (23.5%) had exposed buccal surfaces. There were no statistically significant differences for intragroup and intergroup comparisons (χ² test, P > .05). This study failed to find statistically significant differences in the frequency of implants with exposed buccal surfaces placed virtually, following treatment of compromised and noncompromised sockets. A high proportion (22% to 44%) of sites had implants that potentially needed additional regenerative procedures.

  15. High-frequency pulsed low-level diode laser therapy accelerates wound healing of tooth extraction socket: An in vivo study.

    PubMed

    Noda, Masahiro; Aoki, Akira; Mizutani, Koji; Lin, Taichen; Komaki, Motohiro; Shibata, Shunichi; Izumi, Yuichi

    2016-12-01

    This study aimed to evaluate the effects of high-frequency pulsed (HiFP) low-level laser therapy (LLLT) on early wound healing of tooth extraction sockets in rats. Bilateral maxillary first molars were extracted from 6-week-old Sprague-Dawley rats. Sockets on the right were treated by HiFP low-level diode laser irradiation (904-910 nm); the left sides served as unirradiated controls. LLLT (0.28 W, 30 kHz, 200-ns pulse, 0.6% duty cycle, 61.2 J/cm 2 total power density) was employed immediately after extraction and every 24 hours thereafter. The maxillae including the sockets were resected 3 or 7 days after extraction. Soft-tissue healing was evaluated on days 0, 3, and 7. The bone mineral content (BMC), bone volume (BV), and bone mineral density (BMD) of the extraction sockets were evaluated by microcomputed tomography, and histomorphometric analysis was carried out on day 7. Real-time PCR analysis of osteogenic marker expression and immunohistochemical detection of proliferating cell nuclear antigen (PCNA)-positive cells were performed on day 3. Compared with control sites, the un-epithelialized areas of the extracted sites were significantly reduced by irradiation (P = 0.04), and the BMC, BV, and BMD of laser-treated sites were significantly increased (P = 0.004, 0.006, and 0.009, respectively). On day 7, the mean height of newly formed immature woven bone was higher in laser-treated sites (P = 0.24). On day 3, laser-treated sites showed significantly higher osteocalcin mRNA expression (P = 0.04) and PCNA-positive cell numbers (P = 0.01). HiFP low-level diode laser irradiation enhanced soft- and hard-tissue healing of tooth extraction sockets. Lasers Surg. Med. 48:955-964, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. Ridge preservation of extraction sockets with chronic pathology using Bio-Oss® Collagen with or without collagen membrane: an experimental study in dogs.

    PubMed

    Kim, Jung-Ju; Schwarz, Frank; Song, Hyun Young; Choi, YoonMi; Kang, Kyung-Rim; Koo, Ki-Tae

    2017-06-01

    This study aimed to evaluate the dynamics of newly bone formation and dimensional change in diseased extraction sockets using Bio-Oss ® Collagen with or without a collagen membrane. In six beagle dogs, right and left 3rd and 4th mandibular premolars were hemisected and the distal roots were removed. Combined endodontic-periodontic lesions were induced in all sites using black silk, collagen sponge, endodontic files, and application of Porphyromonas gingivalis. After 4 months, among 4 premolars, three teeth were randomly selected per dog and allocated to the following experimental groups: Control group (no treatment but debridement), Test 1 group (only Bio-Oss ® Collagen graft), and Test 2 group (Bio-Oss ® Collagen graft with a collagen membrane). After 7 months from the baseline, the beagle dogs were sacrificed for histomorphometric and Micro-CT analysis. The vertical distance between buccal and lingual crests in the Control group (2.22 ± 0.26 mm) and Test 2 group (1.80 ± 0.16 mm) was significantly different. The socket of the Test 2 group (27.04 ± 5.25%) was occupied by a greater quantity of bone graft compared to the Test 1 group (18.49 ± 2.11%). Ridge preservation in diseased extraction sockets could compensate for buccal bone resorption by contact osteogenesis surrounding the bone graft particles at the bucco-coronal area during socket healing, and the application of a collagen membrane at the entrance of the socket is useful for preserving graft material at the coronal part of the socket. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Sol-gel antireflective spin-coating process for large-size shielding windows

    NASA Astrophysics Data System (ADS)

    Belleville, Philippe F.; Prene, Philippe; Mennechez, Francoise; Bouigeon, Christian

    2002-10-01

    The interest of the antireflective coatings applied onto large-area glass components increases everyday for the potential application such as building or shop windows. Today, because of the use of large size components, sol-gel process is a competitive way for antireflective coating mass production. The dip-coating technique commonly used for liquid-deposition, implies a safety hazard due to coating solution handling and storage in the case of large amounts of highly flammable solvent use. On the other hand, spin-coating is a liquid low-consumption technique. Mainly devoted to coat circular small-size substrate, we have developed a spin-coating machine able to coat large-size rectangular windows (up to 1 x 1.7 m2). Both solutions and coating conditions have been optimized to deposit optical layers with accurate and uniform thickness and to highly limit the edge effects. Experimental single layer antireflective coating deposition process onto large-area shielding windows (1000 x 1700 x 20 mm3) is described. Results show that the as-developed process could produce low specular reflection value (down to 1% one side) onto white-glass windows over the visible range (460-750 nm). Low-temperature curing process (120°C) used after sol-gel deposition enables antireflective-coating to withstand abrasion-resistance properties in compliance to US-MIL-C-0675C moderate test.

  18. Alveolar ridge preservation of an extraction socket using autogenous tooth bone graft material for implant site development: prospective case series

    PubMed Central

    Yun, Pil-Young; Um, In-Woong; Lee, Hyo-Jung; Yi, Yang-Jin; Bae, Ji-Hyun; Lee, Junho

    2014-01-01

    This case series evaluated the clinical efficacy of autogenous tooth bone graft material (AutoBT) in alveolar ridge preservation of an extraction socket. Thirteen patients who received extraction socket graft using AutoBT followed by delayed implant placements from Nov. 2008 to Aug. 2010 were evaluated. A total of fifteen implants were placed. The primary and secondary stability of the placed implants were an average of 58 ISQ and 77.9 ISQ, respectively. The average amount of crestal bone loss around the implant was 0.05 mm during an average of 22.5 months (from 12 to 34 months) of functional loading. Newly formed tissues were evident from the 3-month specimen. Within the limitations of this case, autogenous tooth bone graft material can be a favorable bone substitute for extraction socket graft due to its good bone remodeling and osteoconductivity. PMID:25551013

  19. The Keck keyword layer

    NASA Technical Reports Server (NTRS)

    Conrad, A. R.; Lupton, W. F.

    1992-01-01

    Each Keck instrument presents a consistent software view to the user interface programmer. The view consists of a small library of functions, which are identical for all instruments, and a large set of keywords, that vary from instrument to instrument. All knowledge of the underlying task structure is hidden from the application programmer by the keyword layer. Image capture software uses the same function library to collect data for the image header. Because the image capture software and the instrument control software are built on top of the same keyword layer, a given observation can be 'replayed' by extracting keyword-value pairs from the image header and passing them back to the control system. The keyword layer features non-blocking as well as blocking I/O. A non-blocking keyword write operation (such as setting a filter position) specifies a callback to be invoked when the operation is complete. A non-blocking keyword read operation specifies a callback to be invoked whenever the keyword changes state. The keyword-callback style meshes well with the widget-callback style commonly used in X window programs. The first keyword library was built for the two Keck optical instruments. More recently, keyword libraries have been developed for the infrared instruments and for telescope control. Although the underlying mechanisms used for inter-process communication by each of these systems vary widely (Lick MUSIC, Sun RPC, and direct socket I/O, respectively), a basic user interface has been written that can be used with any of these systems. Since the keyword libraries are bound to user interface programs dynamically at run time, only a single set of user interface executables is needed. For example, the same program, 'xshow', can be used to display continuously the telescope's position, the time left in an instrument's exposure, or both values simultaneously. Less generic tools that operate on specific keywords, for example an X display that controls optical

  20. Water window imaging x ray microscope

    NASA Technical Reports Server (NTRS)

    Hoover, Richard B. (Inventor)

    1992-01-01

    A high resolution x ray microscope for imaging microscopic structures within biological specimens has an optical system including a highly polished primary and secondary mirror coated with identical multilayer coatings, the mirrors acting at normal incidence. The coatings have a high reflectivity in the narrow wave bandpass between 23.3 and 43.7 angstroms and have low reflectivity outside of this range. The primary mirror has a spherical concave surface and the secondary mirror has a spherical convex surface. The radii of the mirrors are concentric about a common center of curvature on the optical axis of the microscope extending from the object focal plane to the image focal plane. The primary mirror has an annular configuration with a central aperture and the secondary mirror is positioned between the primary mirror and the center of curvature for reflecting radiation through the aperture to a detector. An x ray filter is mounted at the stage end of the microscope, and film sensitive to x rays in the desired band width is mounted in a camera at the image plane of the optical system. The microscope is mounted within a vacuum chamber for minimizing the absorption of x rays in air from a source through the microscope.

  1. Magnesium-enriched hydroxyapatite compared to calcium sulfate in the healing of human extraction sockets: radiographic and histomorphometric evaluation at 3 months.

    PubMed

    Crespi, Roberto; Capparè, Paolo; Gherlone, Enrico

    2009-02-01

    Reduction of alveolar height and width after tooth extraction may present problems for implant placement, especially in the anterior maxilla where bone volume is important for biologic and esthetic reasons. Different graft materials have been proposed to minimize the reduction in ridge volume. The aim of this study was to compare radiographic and histomorphometric results of magnesium-enriched hydroxyapatite (MHA) and calcium sulfate (CS) grafts in fresh sockets after tooth extractions. Forty-five fresh extraction sockets with three bone walls were selected in 15 patients. A split-mouth design was used: 15 sockets on the right side of the jaw received MHA, 15 sockets on the left side received CS, and 15 random unfilled sockets were considered the control (C) group. Intraoral digital radiographs were taken at baseline and at 3 months after graft material placement. At 3 months, cylinder bone samples were obtained for histology and histomorphometry analysis. The difference in mean radiographic vertical bone level from baseline to 3 months was -2.48 +/- 0.65 mm in the CS group, -0.48 +/- 0.21 mm in the MHA group, and -3.75 +/- 0.63 mm in the unfilled C group. Statistically significant differences (P <0.05) were found between CS and MHA groups and between MHA and C groups. Histologic examination revealed bone formation in all treated sites; trabecular bone assessment did not differ among apical, mesial, and coronal portions of the specimens. Mean vital bone measurements for CS, MHA, and C groups were 45.0% +/- 6.5%, 40.0% +/- 2.7%, and 32.8% +/- 5.8%, respectively. Statistically significant differences (P <0.05) were found among all groups. Connective tissue percentages averaged 41.5% +/- 6.7% for the CS group, 41.3% +/- 1.3% for the MHA group, and 64.6% +/- 6.8% for the C group. Statistically significant differences (P <0.05) were found between CS and C groups and between MHA and C groups. The CS-grafted sockets showed 13.9% +/- 3.4% residual implant material, whereas

  2. Replacement Windows for Existing Homes Homes | Efficient Windows

    Science.gov Websites

    Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Selection Tool will take you through a series of design conditions pertaining to your design and location

  3. Purposeful exposure of a polylactic acid barrier to achieve socket preservation for placement of dental implants: case series report.

    PubMed

    Rosen, Paul S; Rosen, Adam D

    2013-01-01

    This retrospective case series reports on the use of a polylactic acid barrier that was left exposed in the process of socket preparation for the placement of dental implants. A retrospective chart review found 43 patients with 48 extraction sockets that were treated in this manner. Teeth were removed and the sockets were thoroughly debrided, with 40 of them receiving a bone replacement graft covered by the polylactic acid barrier and the additional 8 receiving the membrane alone. Suturing left the barrier exposed, and the sites were re-entered on average at 23 weeks for the placement of a dental implant. All sites were able to receive a dental implant, demonstrating the ability to leave a polylactic acid barrier exposed and achieve successful guided bone regeneration (GBR) results. This ultimately helped avoid some of the negative sequelae of trying to achieve primary closure of the flaps at the time of tooth extraction.

  4. A study on fatigue strength reduction factor for small diameter socket welded pipe joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higuchi, Makoto; Nakagawa, Akira; Hayashi, Makoto

    1996-12-01

    Factors that may exert influence on the fatigue strength of small diameter socket welded joints of nominal diameter in the 20--50 mm range have been investigated by the fully reversed four-point bending fatigue test with the material, diameter, pipe schedule, throat depth, bead shape, slip-on gap, and root defect as the testing parameters. The fatigue strength of socket joints depended acutely on the diameter. When the diameter is large, the fatigue strength tended to be low and the fracture is of the root-failure mode; when it is small, on the other hand, the fatigue strength is high and the fracturemore » is of the toe-failure mode. Stainless steel proved to be superior to carbon steel; it gave rise to 1.37 times the fatigue strength of the latter for socket joints of nominal diameter 50 mm; the fatigue strength reduction factor determined at 10{sup 7} cycles with respect to the fatigue strength of smooth base metal in the fully reversed fatigue was about 4 for stainless steel and about 5 for carbon steel. The fatigue strength was higher, the larger the Sche number (i.e., the thicker the pipe wall); it was improved markedly by placing one final refinement pass on the toe or by eliminating the slip-on gap. An empirical formula relating the size of the root defect to the fatigue strength reduction has been proposed.« less

  5. Sensitivity distribution of a vibration sensor based on Mach-Zehnder interferometer designed inside the window system

    NASA Astrophysics Data System (ADS)

    Zboril, Ondrej; Nedoma, Jan; Cubik, Jakub; Novak, Martin; Bednarek, Lukas; Fajkus, Marcel; Vasinek, Vladimir

    2016-04-01

    Interferometric sensors are very accurate and sensitive sensors that due to the extreme sensitivity allow sensing vibration and acoustic signals. This paper describes a new method of implementation of Mach-Zehnder interferometer for sensing of vibrations caused by touching on the window panes. Window panes are part of plastic windows, in which the reference arm of the interferometer is mounted and isolated inside the frame, a measuring arm of the interferometer is fixed to the window pane and it is mounted under the cover of the window frame. It prevents visibility of the optical fiber and this arrangement is the basis for the safety system. For the construction of the vibration sensor standard elements of communication networks are used - optical fiber according to G.652D and 1x2 splitters with dividing ratio 1:1. Interferometer operated at a wavelength of 1550 nm. The paper analyses the sensitivity of the window in a 12x12 measuring points matrix, there is specified sensitivity distribution of the window pane.

  6. A Multidisciplinary Approach for Rehabilitation of Enucleated Sockets: Ocular Implants with Custom Ocular Prosthesis.

    PubMed

    Choudhury, Minati; Banu, Fathima; Natarajan, Shanmuganathan; Kumar, Anand; Tv, Padmanabhan

    2018-02-16

    Interdisciplinary prosthodontics goes beyond our imagination into fields that have a direct effect on our total body health and quality of life. Removal of an eye has a detrimental effect on the psychology of the patient. Enucleation involves removal of the eyeball proper and leads to an enophthalmic socket with a shrunken eye, which has a crippling effect on patient's emotional and social life. Custom-made eye prosthesis simulates the characteristics of the companion eye and helps in restoring the normal facial appearance. Restoration of saccadic eye movements occurring during speech is desirable because this greatly contributes to a normal facial expression. This can be achieved by an orbital implant, which helps in orbital volume replacement and restoration of prosthesis movement and comfort. This article describes prosthodontic rehabilitation of enucleated eye sockets with orbital implants for two patients.

  7. Gravity Perception in a Cladoceran-zooplankter: Anatomy of Antennal Socket Setae of Daphnia Magna

    NASA Technical Reports Server (NTRS)

    Meyers, D. G.

    1985-01-01

    Night orientation in Daphnia magna was recently associated with setae on the basal socket of the swimming antennae. Daphnids are suspected of maintaining nocturnal equilibrium by monitoring the gravity vector through upward setal deflections caused by sinking between antennal swimming strokes. Setae appear to be hydrodynamic rheoceptors that sense the gravity vector indirectly by mechanoreceptivity to the direction and velocity of water currents. Neuroanatomical stains have revealed cell bodies at the base of the setal shafts, dendritic connections through to the distal ends of the shafts, and axonal tracts around the antennal socket connecting with an additional cell body and continuing toward the brain. These anatomical observations combined with previous scanning electron microscopy studies suggest that the setae are similar to mechanoreceptors and propreceptors used by higher crustaceans to sense water currents and gravity, and maintained balance.

  8. Systematic search for wide periodic windows and bounds for the set of regular parameters for the quadratic map.

    PubMed

    Galias, Zbigniew

    2017-05-01

    An efficient method to find positions of periodic windows for the quadratic map f(x)=ax(1-x) and a heuristic algorithm to locate the majority of wide periodic windows are proposed. Accurate rigorous bounds of positions of all periodic windows with periods below 37 and the majority of wide periodic windows with longer periods are found. Based on these results, we prove that the measure of the set of regular parameters in the interval [3,4] is above 0.613960137. The properties of periodic windows are studied numerically. The results of the analysis are used to estimate that the true value of the measure of the set of regular parameters is close to 0.6139603.

  9. Nuclear reactor fuel assembly duct-tube-to-handling-socket attachment system

    DOEpatents

    Christiansen, David W.; Smith, Bob G.

    1982-01-01

    A reusable system for removably attaching the upper end 10of a nuclear reactor duct tube to the lower end 30 of a nuclear reactor fuel assembly handling socket. A transition ring 20, fixed to the duct tube's upper end 10, has an interior-threaded section 22 with a first locking hole segment 24. An adaptor ring 40, fixed to the handling socket's lower end 30 has an outside-threaded section 42 with a second locking hole segment 44. The inside 22 and outside 42 threaded sections match and can be joined so that the first 24 and second 44 locking hole segments can be aligned to form a locking hole. A locking ring 50, with a locking pin 52, slides over the adaptor ring 40 so that the locking pin 52 fits in the locking hole. A swage lock 60 or a cantilever finger lock 70 is formed from the locking cup collar 26 to fit in a matching groove 54 or 56 in the locking ring 50 to prevent the locking ring's locking pin 52 from backing out of the locking hole.

  10. The influence of platelet-rich plasma on the healing of extraction sockets: an explorative randomised clinical trial.

    PubMed

    Alissa, Rami; Esposito, Marco; Horner, Keith; Oliver, Richard

    2010-01-01

    To investigate the effect of platelet-rich plasma (PRP) on the healing of hard and soft tissues of extraction sockets with a pilot study. Patients undergoing tooth extraction under intravenous sedation were asked to participate in the trial. Autologous platelet concentrates were prepared from the patients' blood and autologous thrombin was produced. Outcome measures were: pain level, analgesic consumption, oral function (ability to eat food, swallowing, mouth opening and speech), general activity, swelling, bruising, bleeding, bad taste or halitosis, food stagnation, patient satisfaction, healing complications, soft tissue healing, trabecular pattern of newly formed bone in extraction sockets, trabecular bone volume, trabecular separation, trabecular length, trabecular width, and trabecular number. Patients were followed up to 3 months post-extraction. Twelve patients (15 sockets) were randomly allocated to the PRP group and 11 patients (14 sockets) to the control group. Two patients from the control group did not attend any of the scheduled appointments following tooth extraction, and were considered dropouts. Additionally, one more patient from the control group and four patients from the PRP group did not attend their 3-month radiographic assessment appointments. Statistically significantly more pain was recorded in the control group for the first (P=0.02), second (P=0.02) and third (P=0.04) post-operative days for Visual Analogue Scale scores, whereas no differences were observed for the fourth (P=0.17), fifth (P=0.38), sixth (P=0.75) and seventh (P=0.75) post-operative days. There was a statistically significantly higher analgesic consumption for the first (P=0.03) and second (P=0.02) post-operative days in the control group and no differences thereafter. Differences in patients' responses in the health-related quality of life questionnaire were statistically significant in favour of PRP treatment only for the presence of bad taste or bad smell in the mouth (P

  11. Do systemic antibiotics prevent dry socket and infection after third molar extraction? A systematic review and meta-analysis.

    PubMed

    Ramos, Eva; Santamaría, Joseba; Santamaría, Gorka; Barbier, Luis; Arteagoitia, Icíar

    2016-10-01

    The use of antibiotics to prevent dry socket and infection is a controversial but widespread practice. The aim of the study is to assess the efficacy of systemic antibiotics in reducing the frequencies of these complications after extraction. A systematic review and meta-analysis, according to the PRISMA statement, based on randomized double-blind placebo-controlled trials evaluating systemic antibiotics to prevent dry socket and infection after third molar surgery. Databases were searched up to June 2015. Relative risks (RRs) were calculated with inverse variance-weighted, fixed-effect, or random-effect models. We included 22 papers in the qualitative and 21 in the quantitative review (3304 extractions). Overall-RR was 0.43 (95% confidence interval [CI] 0.33-0.56; P < .0001); number needed to treat, 14 (95% CI 11-19). Penicillins-RR: 0.40 (95% CI 0.27-0.59). Nitroimidazoles-RR: 0.56 (95% CI 0.38-0.82). No serious adverse events were reported. Systemic antibiotics significantly reduce the risk of dry socket and infection in third molar extraction. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. The use of a direct manufacturing prosthetic socket system in a rural community in South Africa: A pilot study and lessons for future research.

    PubMed

    Ennion, Liezel; Johannesson, Anton; Rhoda, Anthea

    2017-10-01

    Challenges exist with the provision of appropriate mobility assistive devices in rural areas. The use of the direct manufacturing prosthetic socket system is a possible solution to these challenges. The objective of this study was to test and explore the clients' perspectives with the application of this device. Within a mixed-methods approach, a longitudinal sequential explanatory design was applied. The Orthotic and Prosthetic User's Survey was administered to explore the use of the direct manufacturing prosthetic socket system in terms of function, health-related quality of life and client satisfaction. A conveniently selected sample of 21 individuals who suffered a unilateral trans-tibial amputation was included. Data were collected at 1, 3 and 6 months post fitting, and two focus group discussions were also administered. Of the 21 participants recruited, 11 returned for follow up. Although participants reported favourably about the prosthesis, their scores were generally worse than the norms with regard to function and quality of life. Participants highlighted the need for improvement in the cosmetic appearance of the prosthesis. The direct manufacturing prosthetic socket system could be considered as an alternative technique of socket manufacturing for individuals living in rural areas due to the shorter manufacture time and promising initial results, but further research on this topic with a bigger sample is recommended. Clinical relevance The direct manufacturing prosthetic socket system may be considered as an alternative to the traditional prosthetic socket manufacturing technique used in South Africa. As this device requires only one visit and therefore decreased travel by the patients to the hospitals, it could be applicable to more amputees who cannot return to hospital post discharge.

  13. Osseointegration of dental implants in extraction sockets preserved with porous titanium granules - an experimental study.

    PubMed

    Verket, Anders; Lyngstadaas, Ståle P; Rønold, Hans J; Wohlfahrt, Johan C

    2014-02-01

    This study investigated osseointegration of dental implants inserted in healed extraction sockets preserved with porous titanium granules (PTG). Three adult female minipigs (Gøttingen minipig; Ellegaard A/S, Dalmose, Denmark) had the mandibular teeth P2, P3 and P4 extracted. The extraction sockets were preserved with metallic PTG (Tigran PTG; Tigran Technologies AB, Malmö, Sweden) n = 12, heat oxidized white porous titanium granules (WPTG) (Tigran PTG White) n = 12 or left empty (sham) n = 6. All sites were covered with collagen membranes (Bio-Gide; Geistlich Pharma, Wolhausen, Switzerland) and allowed 11 weeks of healing before implants (Straumann Bone Level; Straumann, Basel, Switzerland) were inserted. The temperature was measured during preparation of the osteotomies. Resonance frequency analysis (RFA, Osstell; Osstell AB, Gothenburg, Sweden) was performed at implant insertion and at termination. After 6 weeks of submerged implant healing, the pigs were euthanized and jaw segments were excised for microCT and histological analyses. In the temperature and RFA analyses no significant differences were recorded between the test groups. The microCT analysis demonstrated an average bone volume of 61.7% for the PTG group compared to 50.3% for the WPTG group (P = 0.03) and 57.1% for the sham group. Histomorphometry demonstrated an average bone-to-implant contact of 68.2% for the PTG group compared to 36.6% for the WPTG group and 60.9% for the sham group (n.s). Eight out of ten implants demonstrated apical osseous defects in the WPTG group, but similar defects were observed in all groups. PTG preserved extraction sockets demonstrate a similar outcome as the sham control group for all analyses suggesting that this material potentially can be used for extraction socket preservation prior to implant installment. Apical osseous defects were however observed in all groups including the sham group, and a single cause could not be determined. © 2012 John Wiley & Sons A/S.

  14. Walking ability and quality of life in subjects with transfemoral amputation: a comparison of osseointegration with socket prostheses.

    PubMed

    Van de Meent, Hendrik; Hopman, Maria T; Frölke, Jan Paul

    2013-11-01

    To investigate walking ability and quality of life of osseointegrated leg prostheses compared with socket prostheses. Prospective case-control study. University medical center. Subjects (N=22) with transfemoral amputation (1 bilateral) referred to our center because of socket-related skin and residual limb problems resulting in limited prosthesis use. Their mean age was 46.5 years (range, 23-67y) and mean time since amputation was 16.4 years (range, 2-45y). Causes of amputation were trauma (n=20) and tumor (n=2). Implantation of an osseointegration prosthesis (OIP). Global score of the Questionnaire for Persons With a Transfemoral Amputation (Q-TFA), prosthesis use, 6-minute walk test (6MWT), Timed Up & Go (TUG) test, and oxygen consumption during treadmill walking. With the socket prosthesis, the mean ± SD Q-TFA global score, prosthesis use, 6MWT, TUG, and oxygen consumption were 39±4.7 points, 56±7.9h/wk, 321±28m, 15.1±2.1 seconds, and 1330±310mL/min, respectively, and significantly improved with OIP to 63±5.3 points, 101±2.4h/wk, 423±21m, 8.1±0.7 seconds, and 1093±361mL/min, respectively. Osseointegration is a suitable intervention for persons whose prosthesis use is reduced because of socket-related problems. Subjects with OIP significantly increased their walking ability and prosthesis-related quality of life. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. Muon catalyzed fusion beam window mechanical strength testing and analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ware, A.G.; Zabriskie, J.M.

    A thin aluminum window (0.127 mm (0.005-inch) thick x 146 mm (5 3/4-inch) diameter) of 2024-T6 alloy was modeled and analyzed using the ABAQUS non-linear finite element analysis code. A group of windows was fabricated, heat-treated and subsequently tested. Testing included both ultimate burst pressure and fatigue. Fatigue testing cycles involved ''oil-canning'' behavior representing vacuum purge and reversal to pressure. Test results are compared to predictions and the mode of failure is discussed. Operational requirements, based on the above analysis and correlational testing, for the actual beam windows are discussed. 1 ref., 3 figs.

  16. The design of an intelligent human-computer interface for the test, control and monitor system

    NASA Technical Reports Server (NTRS)

    Shoaff, William D.

    1988-01-01

    The graphical intelligence and assistance capabilities of a human-computer interface for the Test, Control, and Monitor System at Kennedy Space Center are explored. The report focuses on how a particular commercial off-the-shelf graphical software package, Data Views, can be used to produce tools that build widgets such as menus, text panels, graphs, icons, windows, and ultimately complete interfaces for monitoring data from an application; controlling an application by providing input data to it; and testing an application by both monitoring and controlling it. A complete set of tools for building interfaces is described in a manual for the TCMS toolkit. Simple tools create primitive widgets such as lines, rectangles and text strings. Intermediate level tools create pictographs from primitive widgets, and connect processes to either text strings or pictographs. Other tools create input objects; Data Views supports output objects directly, thus output objects are not considered. Finally, a set of utilities for executing, monitoring use, editing, and displaying the content of interfaces is included in the toolkit.

  17. Osteogenic potential of mesenchymal cells embedded in the provisional matrix after a 6-week healing period in augmented and non-augmented extraction sockets: an immunohistochemical prospective pilot study in humans.

    PubMed

    Heberer, Susanne; Wustlich, Alexander; Lage, Hermann; Nelson, John J; Nelson, Katja

    2012-01-01

    The aim of the present clinical study was the evaluation of the osteogenic potential of mesenchymal cells embedded in the provisional matrix of non-augmented and with Bio-Oss collagen-augmented human extraction sockets after 6 weeks of healing time. Twenty-five patients with 47 extraction sites participated in the present study. After tooth removal, the extraction sockets were augmented with Bio-Oss collagen or not augmented. At implant placement, bone biopsies of the extraction sockets were obtained. The immunohistochemical analysis of the osteogenic potential of the mesenchymal cells in the provisional matrix was performed using three monoclonal antibodies: core-binding factor α1 (Cbfa1)/runt-related protein (Runx)2, osteonectin (OSN/secreted protein acidic and rich in cyst [SPARC]) and osteocalcin (OC). The statistical analysis was performed using two-factorial analysis for repeated measures, Mann-Whitney U-test and Spearman's rank-order correlation coefficient. Of 47 extraction sockets examined, 17 sockets demonstrated an almost complete ossification. Hence, the provisional matrix of the 30 remaining extraction sockets (21 non-augmented, 9 augmented) was immunohistochemically investigated. No evidence of acute or chronic inflammation was noted in any of the specimens. In the provisional matrix of the non-grafted socket, the median amount of Cbfa1/Runx2-positive cells was 72.3%, of OSN (SPARC) 66.9% and of OC 23.4%, whereas in the grafted sockets the median rate of immunopositive cells staining with Cbfa1/Runx2 was 73.3%, of OSN (SPARC) 61.4% and of OC 20.1%. There was no significant difference in the proportion of positive cells expressed by Cbfa1/Runx2, OSN/SPARC and OC between the grafted and non-grafted socket. Furthermore, the cell density did not correlate to the quantity of stained cells independent of the used proteins. After a 6-week healing period, the provisional matrix was demonstrated to have a high proportion of cells displaying a maturation of

  18. High Reflectance Nanoscale V/Sc Multilayer for Soft X-ray Water Window Region.

    PubMed

    Huang, Qiushi; Yi, Qiang; Cao, Zhaodong; Qi, Runze; Loch, Rolf A; Jonnard, Philippe; Wu, Meiyi; Giglia, Angelo; Li, Wenbin; Louis, Eric; Bijkerk, Fred; Zhang, Zhong; Wang, Zhanshan

    2017-10-10

    V/Sc multilayer is experimentally demonstrated for the first time as a high reflectance mirror for the soft X-ray water window region. It primarily works at above the Sc-L edge (λ = 3.11 nm) under near normal incidence while a second peak appears at above the V-L edge (λ = 2.42 nm) under grazing incidence. The V/Sc multilayer fabricated with a d-spacing of 1.59 nm and 30 bilayers has a smaller interface width (σ = 0.27 and 0.32 nm) than the conventional used Cr/Sc (σ = 0.28 and 0.47 nm). For V/Sc multilayer with 30 bilayers, the introduction of B 4 C barrier layers has little improvement on the interface structure. As the number of bilayers increasing to 400, the growth morphology and microstructure of the V/Sc layers evolves with slightly increased crystallization. Nevertheless, the surface roughness remains to be 0.25 nm. A maximum soft X-ray reflectance of 18.4% is measured at λ = 3.129 nm at 9° off-normal incidence using the 400-bilayers V/Sc multilayer. According to the fitted model, an s-polarization reflectance of 5.2% can also be expected at λ = 2.425 nm under 40° incidence. Based on the promising experimental results, further improvement of the reflectance can be achieved by using a more stable deposition system, exploring different interface engineering methods and so on.

  19. Temporal behavior of unresolved transition array emission in water window soft x-ray spectral region from multiply charged ions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dinh, Thanh-Hung, E-mail: dinh@cc.utsunomiya-u.ac.jp; Suzuki, Yuhei; Arai, Goki

    2015-09-21

    We have characterized the spectral structure and the temporal history of the laser-produced high-Z multi-charged ion plasmas for the efficient water window soft x-ray sources. Strong unresolved transition array emission was observed due to 4d–4f and 4f–5g transitions from Au, Pb, and Bi plasmas in the 280–700 eV photon energy region. The temporal behavior of the emission was essentially similar of that of the laser pulse with a slight delay between different transitions. These results provide feedback for accurate modeling of the atomic processes with the radiative hydrodynamic simulations.

  20. Retrospective Analysis of the Outcome of Ridge Preservation with Anorganic Bovine Bone Minerals: Microcomputed Tomographic Assessment of Wound Healing in Grafted Extraction Sockets.

    PubMed

    Bakhshalian, Neema; Freire, Marcelo; Min, Seiko; Wu, Ivy; Zadeh, Homayoun H

    A total of 68 extraction sockets were grafted with anorganic bovine bone mineral and covered by dense polytetrafluoroethylene membrane. Quantitative analysis of three-dimensional microcomputed tomography imaging of core samples retrieved after a mean of 21.0 ± 14.2 weeks revealed 40.1% bone volume fraction (bone volume [BV]/total volume [TV]) and 12% residual graft. Evidence of de novo bone formation was observed in the form of discrete islands of newly formed bone in direct apposition to graft particles, separated from parent bone. Anterior sockets exhibited a significantly higher percentage of residual graft compared to premolar sockets (P = .05). The BV/TV and percentage of residual graft correlated well with histomorphometric analysis of the same sites, but not with implant outcomes.

  1. PCDAQ, A Windows Based DAQ System

    NASA Astrophysics Data System (ADS)

    Hogan, Gary

    1998-10-01

    PCDAQ is a Windows NT based general DAQ/Analysis/Monte Carlo shell developed as part of the Proton Radiography project at LANL (Los Alamos National Laboratory). It has been adopted by experiments outside of the Proton Radiography project at Brookhaven National Laboratory (BNL) and at LANL. The program provides DAQ, Monte Carlo, and replay (disk file input) modes. Data can be read from hardware (CAMAC) or other programs (ActiveX servers). Future versions will read VME. User supplied data analysis routines can be written in Fortran, C++, or Visual Basic. Histogramming, testing, and plotting packages are provided. Histogram data can be exported to spreadsheets or analyzed in user supplied programs. Plots can be copied and pasted as bitmap objects into other Windows programs or printed. A text database keyed by the run number is provided. Extensive software control flags are provided so that the user can control the flow of data through the program. Control flags can be set either in script command files or interactively. The program can be remotely controlled and data accessed over the Internet through its ActiveX DCOM interface.

  2. X-ray transmissive debris shield

    DOEpatents

    Spielman, R.B.

    1996-05-21

    An X-ray debris shield for use in X-ray lithography that is comprised of an X-ray window having a layer of low density foam exhibits increased longevity without a substantial increase in exposure time. The low density foam layer serves to absorb the debris emitted from the X-ray source and attenuate the shock to the window so as to reduce the chance of breakage. Because the foam is low density, the X-rays are hardly attenuated by the foam and thus the exposure time is not substantially increased.

  3. X-ray transmissive debris shield

    DOEpatents

    Spielman, Rick B.

    1996-01-01

    An X-ray debris shield for use in X-ray lithography that is comprised of an X-ray window having a layer of low density foam exhibits increased longevity without a substantial increase in exposure time. The low density foam layer serves to absorb the debris emitted from the X-ray source and attenuate the shock to the window so as to reduce the chance of breakage. Because the foam is low density, the X-rays are hardly attenuated by the foam and thus the exposure time is not substantially increased.

  4. Indium Phosphide Window Layers for Indium Gallium Arsenide Solar Cells

    NASA Technical Reports Server (NTRS)

    Jain, Raj K.

    2005-01-01

    Window layers help in reducing the surface recombination at the emitter surface of the solar cells resulting in significant improvement in energy conversion efficiency. Indium gallium arsenide (In(x)Ga(1-x)As) and related materials based solar cells are quite promising for photovoltaic and thermophotovoltaic applications. The flexibility of the change in the bandgap energy and the growth of InGaAs on different substrates make this material very attractive for multi-bandgap energy, multi-junction solar cell approaches. The high efficiency and better radiation performance of the solar cell structures based on InGaAs make them suitable for space power applications. This work investigates the suitability of indium phosphide (InP) window layers for lattice-matched In(0.53)Ga(0.47)As (bandgap energy 0.74 eV) solar cells. We present the first data on the effects of the p-type InP window layer on p-on-n lattice-matched InGaAs solar cells. The modeled quantum efficiency results show a significant improvement in the blue region with the InP window. The bare InGaAs solar cell performance suffers due to high surface recombination velocity (10(exp 7) cm/s). The large band discontinuity at the InP/InGaAs heterojunction offers a great potential barrier to minority carriers. The calculated results demonstrate that the InP window layer effectively passivates the solar cell front surface, hence resulting in reduced surface recombination and therefore, significantly improving the performance of the InGaAs solar cell.

  5. Systematic plan of building Web geographic information system based on ActiveX control

    NASA Astrophysics Data System (ADS)

    Zhang, Xia; Li, Deren; Zhu, Xinyan; Chen, Nengcheng

    2003-03-01

    A systematic plan of building Web Geographic Information System (WebGIS) using ActiveX technology is proposed in this paper. In the proposed plan, ActiveX control technology is adopted in building client-side application, and two different schemas are introduced to implement communication between controls in users¡ browser and middle application server. One is based on Distribute Component Object Model (DCOM), the other is based on socket. In the former schema, middle service application is developed as a DCOM object that communicates with ActiveX control through Object Remote Procedure Call (ORPC) and accesses data in GIS Data Server through Open Database Connectivity (ODBC). In the latter, middle service application is developed using Java language. It communicates with ActiveX control through socket based on TCP/IP and accesses data in GIS Data Server through Java Database Connectivity (JDBC). The first one is usually developed using C/C++, and it is difficult to develop and deploy. The second one is relatively easy to develop, but its performance of data transfer relies on Web bandwidth. A sample application is developed using the latter schema. It is proved that the performance of the sample application is better than that of some other WebGIS applications in some degree.

  6. Immediate Implant Placement into Extraction Sockets with Labial Plate Dehiscence Defects: A Clinical Case Series.

    PubMed

    Sarnachiaro, Guido O; Chu, Stephen J; Sarnachiaro, Evangelina; Gotta, Sergio Luis; Tarnow, Dennis P

    2016-08-01

    To measure the buccal plate reconstruction of extraction sockets with labial plate dehiscence defects using a bone allograft in combination with an absorbable collagen membrane and a custom-healing abutment at the time of tooth removal. Ten patients underwent immediate implant placement and reconstruction of the buccal plate. Cone beam computed tomography (CBCT) was performed preextraction, immediately after bone grafting and implant placement (day 0), and between 6 and 9 months following implant surgery. Measurements were taken at three levels: coronal (L1), middle (L2), and apical (L3) level. Implants placed into sockets with labial plate dehiscence defects demonstrated radiographic reformation of the labial plate dehiscence defect at 6 to 9 months posttreatment. The net gain in labial plate on cone beam computerized tomography (CBCT) in L1 and L2 was 3.0 mm, where 0 mm existed at pretreatment. The minimum amount of labial plate thickness of 2.0 mm was achieved in all treated sites, evaluated radiographically at 6 to 9 months postoperatively, in a single procedure, without flap elevation and maintaining the gingival architecture and satisfactory esthetics. Placing an absorbable membrane, bone graft, and custom-healing abutment at the time of flapless anterior tooth extraction and immediate implant placement into a socket with a labial osseous dehiscence is a viable clinical technique to reconstitute the absence of the labial bone plate. © 2015 Wiley Periodicals, Inc.

  7. Sinus floor elevation from a maxillary molar tooth extraction socket in a patient with chronic inflammation.

    PubMed

    Tözüm, Tolga F; Dursun, Erhan; Tulunoglu, Ibrahim

    2009-03-01

    The compromised nature of the residual interradicular bone after extraction of periodontally hopeless maxillary molars often requires a sinus elevation procedure to ideally place the implants to accept future prosthesis. Maxillary sinus elevation surgery is a procedure used to increase the volume of bone mass so that dental implants can be placed. This article documents a sinus floor elevation technique through an extraction socket in a 65-year-old white male with chronic inflammation to increase the bone mass after the extraction of a periodontally involved maxillary molar tooth. Computerized tomography revealed an increased thickness of the sinus membrane, which was attributed to possible chronic sinus inflammation and periodontal inflammation. After consultation with the Department of Otolaryngology, it was diagnosed as chronic inflammation without any contraindication for sinus elevation surgery or implant placement. One month after the extraction, the sinus floor elevation surgery was performed through the extraction socket, and implants were placed 4 months later. An uneventful healing was noted after 6 months of osseointegration; two porcelain-fused-to-metal crowns were fabricated. Clinical follow-up took place every 3 months for 3 years, and successful healing was achieved. The patient was satisfied with the esthetic and functional results of the oral rehabilitation. Sinus floor elevation through an extraction socket without any residual bone, followed by dental implant placement, provided successful functional results and acceptable stability.

  8. Lunar laser ranging data processing in a Unix/X windows environment

    NASA Technical Reports Server (NTRS)

    Ricklefs, Randall L.; Ries, Judit G.

    1993-01-01

    In cooperation with the NASA Crustal Dynamics Project initiative placing workstation computers at each of its laser ranging stations to handle data filtering and normalpointing, MLRS personnel have developed a new generation of software to provide the same services for the lunar laser ranging data type. The Unix operating system and X windows/Motif provides an environment for both batch and interactive filtering and normalpointing as well as prediction calculations. The goal is to provide a transportable and maintainable data reduction environment. This software and some sample displays are presented. that the lunar (or satellite) datacould be processed on one computer while data was taken on the other. The reduction of the data was totally interactive and in no way automated. In addition, lunar predictions were produced on-site, another first in the effort to down-size historically mainframe-based applications. Extraction of earth rotation parameters was at one time attempted on site in near-realtime. In 1988, the Crustal Dynamics Project SLR Computer Panel mandated the installation of Hewlett-Packard 9000/360 Unix workstations at each NASA-operated laser ranging station to relieve the aging controller computers of much of their data and communications handling responsibility and to provide on-site data filtering and normal pointing for a growing list of artificial satellite targets. This was seen by MLRS staff as an opportunity to provide a better lunar data processing environment as well.

  9. Lunar laser ranging data processing in a Unix/X windows environment

    NASA Astrophysics Data System (ADS)

    Ricklefs, Randall L.; Ries, Judit G.

    1993-06-01

    In cooperation with the NASA Crustal Dynamics Project initiative placing workstation computers at each of its laser ranging stations to handle data filtering and normalpointing, MLRS personnel have developed a new generation of software to provide the same services for the lunar laser ranging data type. The Unix operating system and X windows/Motif provides an environment for both batch and interactive filtering and normalpointing as well as prediction calculations. The goal is to provide a transportable and maintainable data reduction environment. This software and some sample displays are presented. that the lunar (or satellite) datacould be processed on one computer while data was taken on the other. The reduction of the data was totally interactive and in no way automated. In addition, lunar predictions were produced on-site, another first in the effort to down-size historically mainframe-based applications. Extraction of earth rotation parameters was at one time attempted on site in near-realtime. In 1988, the Crustal Dynamics Project SLR Computer Panel mandated the installation of Hewlett-Packard 9000/360 Unix workstations at each NASA-operated laser ranging station to relieve the aging controller computers of much of their data and communications handling responsibility and to provide on-site data filtering and normal pointing for a growing list of artificial satellite targets. This was seen by MLRS staff as an opportunity to provide a better lunar data processing environment as well.

  10. Technical reference on socket heat fusion joining of polyethylene gas pipes. Volume 2. Topical Report, September 1989-September 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pimputkar, S.M.; McCoy, J.K.; Stets, J.A.

    1991-03-01

    The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipemore » dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion joint samples in shear. The developed shear impact energy test data were found to be reliable measures of strength if the setup conditions were meticulously identical. A parameter, termed the socket joining parameter, was found to characterize the joining conditions. It is a strong function of melt volume at the end of the heating phase, and, physically, it is polyethylene transported parallel to the axis during insertion. The results for three resins are presented in the form of three nomographs. The nomographs may be used to select the required heater temperature or the heating time, for a given ambient temperature and a PE resin, to ensure a structurally sound socket heat fusion joint.« less

  11. 3D reconstruction of the structure of a residual limb for customising the design of a prosthetic socket.

    PubMed

    Shuxian, Zheng; Wanhua, Zhao; Bingheng, Lu

    2005-01-01

    Aiming at overcoming the limitations of the plaster-casting method in traditional prosthetic socket fabrication, the idea of reconstructing the 3D models for bones and skin of the residual limb is proposed. Given the two-dimensional obtained image through CT scanning, using image processing and reverse engineering techniques, the 3D solid model of the residual limb can be successfully reconstructed. The new approach can reproduce both the internal and the external structure of the residual limb. It can moreover avoid making a positive mould by the way of manual modifications. In addition to this, it can provide a scientific basis for the individualization of prosthetic socket design.

  12. Potential for Osseous Regeneration of Platelet-Rich Fibrin-A Comparative Study in Mandibular Third Molar Impaction Sockets.

    PubMed

    Varghese, Mathew P; Manuel, Suvy; Kumar L K, Surej

    2017-07-01

    This study investigated the potential of platelet-rich fibrin (PRF) for osseous regeneration and soft tissue healing in mandibular third molar impaction sockets. A prospective in vivo study was performed. Randomization was performed after extraction. On one side, the socket was sutured primarily (control site); on the other side, autologous PRF gel was placed and then the socket was sutured (test site). Postoperatively, grid periapical radiographs were obtained at periodic intervals (weeks 1, 4, and 16) and digitalized. Gray-level values were measured at 3 different regions of the socket (for regions of newly formed bone) compared with the natural bone area using HL Image++ software, and the percentage bone fill was measured. Clinical evaluation of soft tissue healing was performed using the healing index of Landry et al (J Periodontol 60:212, 1994) at the specific intervals. Thirty healthy men and women (age range, 18 to 35 yr) with bilaterally impacted mandibular third molars were enrolled in this study. In general, there was markedly greater bone formation in sockets treated with PRF (P < .05). In the PRF group, the average gray-level values at the cervical, middle, and apical regions were 61.85 (standard deviation [SD], ±25.186), 64.54 (SD, ±24.831), and 67.80 (SD, ±23.946), respectively, with a mean value of 64.73 (SD, ±24.411). In the control group, these values were 51.58 (SD, ±15.286), 54.30 (SD, ±16.274), and 57.53 (SD, ±16.187), respectively, with a mean of 53.67 (SD, ±16.528). The average percentage of bone fill in the PRF group was 57.90 (SD, ±26.789) and that of the non-PRF group was 46.74 (SD, ±17.713; P < .05). Soft tissue healing as evaluated by the healing index of Landry et al also was found to be better at the PRF test site and it was statistically significant (P < .05). There was evidence for better osseous regeneration and soft tissue healing in response to PRF. Further investigations to evaluate the application of PRF in other

  13. Dental implants inserted in fresh extraction sockets versus healed sites: a systematic review and meta-analysis.

    PubMed

    Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2015-01-01

    To test the null hypothesis of no difference in the implant failure rates, postoperative infection and marginal bone loss for the insertion of dental implants in fresh extraction sockets compared to the insertion in healed sites, against the alternative hypothesis of a difference. Main search terms used in combination: dental implant, oral implant, resh extraction socket, immediate placement, immediate insertion, immediate implant. An electronic search was undertaken in July/2014, in PubMed, Web of Science, Cochrane Oral Health Group Trials Register plus hand-searching. Eligibility criteria included clinical human studies, either randomized or not. The search strategy resulted in 73 publications, with 8,241 implants inserted in sockets (330 failures, 4.00%), and 19,410 in healed sites (599 failures, 3.09%). It is suggested that the insertion of implants in fresh extraction sockets affects the failure rates (RR 1.58, 95% CI 1.27-1.95, P<0.0001). The difference was not statistically significant when studies evaluating implants inserted in maxillae or in mandibles were pooled, or when the studies using implants to rehabilitate patients with full-arch prostheses were pooled; however, it was significant for the studies that rehabilitated patients with implant-supported single crowns and for the controlled studies. There was no apparent significant effect on the occurrence of postoperative infection or on the magnitude of marginal bone loss. The results should be interpreted with caution due to the potential for biases and to the presence of uncontrolled confounding factors in the included studies, most of them not randomized. The question whether immediate implants are more at risk for failure than implants placed in mature bone has received increasing attention in the last years. As the philosophies of treatment alter over time, a periodic review of the different concepts is necessary to refine techniques and eliminate unnecessary procedures. This would form a basis

  14. Bone Regeneration of Hydroxyapatite with Granular Form or Porous Scaffold in Canine Alveolar Sockets

    PubMed Central

    JANG, SEOK JIN; KIM, SE EUN; HAN, TAE SUNG; SON, JUN SIK; KANG, SEONG SOO; CHOI, SEOK HWA

    2017-01-01

    This study was undertaken to assess bone regeneration using hydroxyapatite (HA). The primary focus was comparison of bone regeneration between granular HA (gHA) forms and porous HA (pHA) scaffold. The extracted canine alveolar sockets were divided with three groups: control, gHA and pHA. Osteogenic effect in the gHA and pHA groups showed bone-specific surface and bone mineral density to be significantly higher than that of the control group (p<0.01). Bone volume fraction, bone mineral density, and amount of connective tissue related to disturbing osseointegration of the gHA group was higher than in the pHA group. Quantity of new bone formation of the pHA group was higher than that of the gHA group. This study demonstrated that gHA and pHA are potentially good bone substitutes for alveolar socket healing. For new bone formation during 8 weeks' post-implantation, HA with porous scaffold was superior to the granular form of HA. PMID:28438860

  15. A study of internet of things real-time data updating based on WebSocket

    NASA Astrophysics Data System (ADS)

    Wei, Shoulin; Yu, Konglin; Dai, Wei; Liang, Bo; Zhang, Xiaoli

    2015-12-01

    The Internet of Things (IoT) is gradually entering the industrial stage. Web applications in IoT such as monitoring, instant messaging, real-time quote system changes need to be transmitted in real-time mode to client without client constantly refreshing and sending the request. These applications often need to be as fast as possible and provide nearly real-time components. Real-time data updating is becoming the core part of application layer visualization technology in IoT. With support of data push in server-side, running state of "Things" in IoT could be displayed in real-time mode. This paper discusses several current real-time data updating method and explores the advantages and disadvantages of each method. We explore the use of WebSocket in a new approach for real-time data updating in IoT, since WebSocket provides low delay, low network throughput solutions for full-duplex communication.

  16. Stability of implants placed in fresh sockets versus healed alveolar sites: Early findings.

    PubMed

    Gehrke, Sergio Alexandre; da Silva Neto, Ulisses Tavares; Rossetti, Paulo Henrique Orlato; Watinaga, Sidney Eiji; Giro, Gabriela; Shibli, Jamil Awad

    2016-05-01

    The present study measured implant stability quotient (ISQ) values at three different time points after surgical procedures to compare whether the stability values differed between implants placed in fresh extraction sockets versus healed alveolar sites. To measure implant stability, resonance frequency analysis (RFA) was performed in 77 patients (53 women, 24 men) with a total of 120 dental implants. These implants were divided into two groups: Group 1 included 60 implants in healed alveolar sites (22 in the maxilla, 38 in the mandible), and Group 2 included 60 implants in fresh sockets (41 in the maxilla, 19 in the mandible). Implant stability was measured immediately at implant placement (baseline), 90, and 150 days later. Statistical analysis was made using a multivariate regression linear model at implant level (α = 0.05). Overall, the means and standard deviations of the ISQ values were 62.7 ± 7.14 (95% confidence interval [CI], 39-88) at baseline, 70.0 ± 6.22 (95% CI, 46-88) at 90 days, and 73.4 ± 5.84 (95% CI, 58-88) at 150 days. In Group 1, the ISQs ranged between 64.3 ± 6.20 and 75.0 ± 5.69, while in Group 2, presented lower values that ranged between 61.2 ± 8.09 and 71.9 ± 5.99 (P = 0.002). Anatomic location and times periods were the only identified variables with an influence on ISQ values at implant level (P < 0.0001). The stabilities of the implants placed in the fresh sockets and in healed sites exhibited similar evolutions in ISQ values and thus osseointegration; however, the implants in the healed alveolar sites exhibited superior values at all time points. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Secondary reconstruction of a mobile eye socket 30 years after enucleation of the eyeball for retinoblastoma: a case report.

    PubMed

    Okumoto, T; Koike, G; Yoshimura, Y

    2014-03-01

    A mobile eye socket is generally reconstructed by inserting an implant into the scleral pocket immediately after bulbar exenteration, or by attaching the extra-ocular muscles to the implanted artificial eyeball immediately after enucleation. However, exposure of the implanted material and other problems can occur. We achieved satisfactory reconstruction of a mobile eye socket by using an autogenous cartilage graft and a pericranial flap in a patient with long-standing anophthalmia due to enucleation. This case is presented with a review of the relevant literature. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Immediate Implant Placement in Sockets with Asymptomatic Apical Periodontitis.

    PubMed

    Crespi, Roberto; Capparé, Paolo; Crespi, Giovanni; Lo Giudice, Giuseppe; Gastaldi, Giorgio; Gherlone, Enrico

    2017-02-01

    The purpose of the present study was to evaluate if the presence of granulation tissue in asymptomatic apical periodontitis compromised immediate implant placement. Patients requiring extraction of one tooth (maxillary and mandibular incisive, canine or premolar) with asymptomatic apical periodontitis, were recruited for this prospective study. They were randomly scheduled into two groups: in first group (A) including 30 teeth, reactive soft tissue was debrided before implant placement, and in second group (B) including 30 teeth, reactive soft tissue was left in the apical lesion. Implants were positioned immediately after tooth extraction, and were loaded after 3 months in both groups. Cone beam computed tomography was performed before tooth extraction and at 1-year follow-up to evaluate the radiolucency around the root apex and the implant, bucco-lingual bone levels were also checked. Sixty patients were included in this study. Sixty implants were placed immediately after tooth extraction and, at 1-year follow-up, a survival rate of 100% was reported. After one year both groups showed absence of radiolucent zone at the apical region of implants. All fresh sockets presented a buccal-palatal bone reduction in both groups after one year, even if not statistically significant differences were found between baseline bone levels and within groups. Within the limitations of the present study, the immediate placement of implants into the extraction sockets with asymptomatic apical periodontitis, in presence of primary stability, did not lead to an increased rate of complications and rendered an equally favorable type of tissue integration. © 2016 Wiley Periodicals, Inc.

  19. Integrated versus non-integrated orbital implants for treating anophthalmic sockets.

    PubMed

    Schellini, Silvana; El Dib, Regina; Silva, Leandro Re; Farat, Joyce G; Zhang, Yuqing; Jorge, Eliane C

    2016-11-07

    Anophthalmia is the absence of one or both eyes, and it can be congenital (i.e. a birth defect) or acquired later in life. There are two main types of orbital implant: integrated, whereby the implant receives a blood supply from the body that allows for the integration of the prosthesis within the tissue; and non-integrated, where the implant remains separate. Despite the remarkable progress in anophthalmic socket reconstruction and in the development of various types of implants, there are still uncertainties about the real roles of integrated (hydroxyapatite (HA), porous polyethylene (PP), composites) and non-integrated (polymethylmethacrylate (PMMA)/acrylic and silicone) orbital implants in anophthalmic socket treatment. To assess the effects of integrated versus non-integrated orbital implants for treating anophthalmic sockets. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2016), Embase (January 1980 to August 2016), Latin American and Caribbean Health Sciences Literature Database (LILACS) (1982 to August 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 8 August 2016. Randomised controlled trials (RCTs) and quasi-RCTs of integrated and non-integrated orbital implants for treating anophthalmic sockets. Two authors independently selected relevant trials, assessed methodological quality and extracted data. We included three studies with a total of 284 participants (250 included in analysis). The studies were conducted in India, Iran and the Netherlands. The three

  20. Efficient Windows Collaborative | Home

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  1. Resources | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  2. Links | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  3. Smart Adaptive Socket to Improve Fit and Relieve Pain in Wounded Warriors

    DTIC Science & Technology

    2016-10-01

    applications were developed for wireless interaction with the socket system firmware. A control algorithm was designed and tested. Clinical trial...interface, Dynamic segmental volume control, Wireless connection, Pressure control system. 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18...charging jack, and power button are included in the design. A Bluetooth 4 radio is also included to allow for advanced user control via smartphone. The

  4. Modeling and experimental investigation of x-ray spectra from a liquid metal anode x-ray tube

    NASA Astrophysics Data System (ADS)

    David, Bernd R.; Thran, Axel; Eckart, Rainer

    2004-11-01

    This paper presents simulated and measured spectra of a novel type of x-ray tube. The bremsstrahlung generating principle of this tube is based on the interaction of high energetic electrons with a turbulently flowing liquid metal separated from the vacuum by a thin window. We simulated the interaction of 50-150 keV electrons with liquid metal targets composed of the elements Ga, In, Sn, as well as the solid elements C, W and Re used for the electron windows. We obtained x-ray spectra and energy loss curves for various liquid metal/window combinations and thicknesses of the window material. In terms of optimum heat transport a thin diamond window in combination with the liquid metal GaInSn is the best suited system. If photon flux is the optimization criteria, thin tungsten/rhenium windows cooled by GaInSn should be preferred.

  5. Immediate Implant Placement in Single-Tooth Molar Extraction Sockets: A 1- to 6-Year Retrospective Clinical Study.

    PubMed

    Amato, Francesco; Polara, Giorgio

    The aim of this study was to investigate the survival rate of implants immediately placed in fresh extraction sockets of molars in the maxilla and mandible with a single-stage procedure. A total of 102 patients were treated, and 107 implants (53 in the maxilla and 54 in the mandible) were placed in a fresh molar extraction socket and connected to a healing abutment. After a mean follow-up of 3 years (range: 1 to 6 years) 1 implant failed, for a cumulative success rate of 99.06% (98.11% for the mandible and 100% for the maxilla). The results of this study support placement of an implant immediately after the extraction of a molar, applying a single-stage procedure.

  6. Experience with the use of a partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft.

    PubMed

    Birk, Stephanie; Brase, Christoph; Hornung, Joachim

    2014-08-01

    In the further development of alloplastic prostheses for use in middle ear surgery, the Dresden and Cologne University Hospitals, working together with a company, introduced a new partial ossicular replacement prosthesis in 2011. The ball-and-socket joint between the prosthesis and the shaft mimics the natural articulations between the malleus and incus and between the incus and stapes, allowing reaction to movements of the tympanic membrane graft, particularly during the healing process. Retrospective evaluation To reconstruct sound conduction as part of a type III tympanoplasty, partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft was implanted in 60 patients, with other standard partial ossicular replacement prosthesis implanted in 40 patients and 64 patients. Pure-tone audiometry was carried out, on average, 19 and 213 days after surgery. Results of the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft were compared with those of the standard prostheses. Early measurements showed a mean improvement of 3.3 dB in the air-bone gap (ABG) with the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft, giving similar results than the standard implants (6.6 and 6.0 dB, respectively), but the differences were not statistically significant. Later measurements showed a statistically significant improvement in the mean ABG, 11.5 dB, compared with 4.4 dB for one of the standard partial ossicular replacement prosthesis and a tendency of better results to 6.9 dB of the other standard prosthesis. In our patients, we achieved similarly good audiometric results to those already published for the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft. Intraoperative fixation posed no problems, and the postoperative complication rate was low.

  7. Window treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nielson, K.J.

    1990-01-01

    This book includes basic material as well as information the professional needs for designing appropriate window treatments for residential and nonresidential buildings: site, orientation, climate, energy efficiency, sound-proofing, privacy, protection, view, ventilation and interior and exterior aesthetics. Also includes a guide to the window treatment industry, a list of manufacturers, distributors, and retailers, information on window treatment fibers and fabrics, three glossaries, an extensive bibliography, and over 800 illustrations.

  8. Radiation attenuation by single-crystal diamond windows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guthrie, M.; Pruteanu, C. G.; Donnelly, M. -E.

    As artificial diamond becomes more cost effective it is likely to see increasing use as a window for sample environment equipment used in diffraction experiments. Such windows are particularly useful as they exhibit exceptional mechanical properties in addition to being highly transparent to both X-ray and neutron radiation. A key application is in high-pressure studies, where diamond anvil cells (DACs) are used to access extreme sample conditions. However, despite their utility, an important consideration when using single-crystal diamond windows is their interaction with the incident beam. In particular, the Bragg condition will be satisfied for specific angles and wavelengths, leadingmore » to the appearance of diamond Bragg spots on the diffraction detectors but also, unavoidably, to loss of transmitted intensity of the beam that interacts with the sample. This effect can be particularly significant for energy-dispersive measurements, for example, in time-of-flight neutron diffraction work using DACs. This article presents a semi-empirical approach that can be used to correct for this effect, which is a prerequisite for the accurate determination of diffraction intensities.« less

  9. Differences in Femoral Head Penetration Between Highly Cross-Linked Polyethylene Cemented Sockets and Uncemented Liners.

    PubMed

    Morita, Daigo; Seki, Taisuke; Higuchi, Yoshitoshi; Takegami, Yasuhiko; Ishiguro, Naoki

    2017-12-01

    This study aimed at investigating differences in femoral head penetration between highly cross-linked polyethylene (HXLPE) cemented sockets and uncemented liners during 5 years postoperatively. Ninety-six patients (106 hips) with a mean age of 64.4 (range, 35-83) years underwent total hip arthroplasty using a HXLPE cemented socket or liner and were respectively divided into cemented (35 patients [37 hips]) and uncemented (61 patients [69 hips]) groups. Femoral head penetrations were evaluated on both anteroposterior (AP)-view and Lauenstein-view radiographs, and mean polyethylene (PE) wear rates were calculated based on femoral head penetration from 2 to 5 years. Multivariate analyses were performed to assess risk factors for PE wear. At 5 years postoperatively, the cemented and uncemented groups exhibited proximal direction femoral head penetrations of 0.103 mm and 0.124 mm (P = .226) and anterior direction penetrations of 0.090 mm and 0.151 mm (P = .002), respectively. The corresponding mean PE wear rates were 0.004 mm/y and 0.009 mm/y in the AP-view (P = .286) and 0.005 mm/y and 0.012 mm/y in the Lauenstein-view (P = .168), respectively. Left-side operation and high activity were independent risk factors for PE wear on AP-view. When HXLPE was used, all mean PE wear rates were very low and those of cemented sockets and uncemented liners were very similar. PE particle theory suggests that the occurrence of osteolysis and related aseptic loosening might consequently decrease. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. A new method to quantify liner deformation within a prosthetic socket for below knee amputees.

    PubMed

    Lenz, Amy L; Johnson, Katie A; Bush, Tamara Reid

    2018-06-06

    Many amputees who wear a leg prosthesis develop significant skin wounds on their residual limb. The exact cause of these wounds is unclear as little work has studied the interface between the prosthetic device and user. Our research objective was to develop a quantitative method for assessing displacement patterns of the gel liner during walking for patients with transtibial amputation. Using a reflective marker system and a custom clear socket, evaluations were conducted with a clear transparent test socket mounted over a plaster limb model and a deformable limb model. Distances between markers placed on the limb were measured with a digital caliper and then compared with data from the motion capture system. Additionally, the rigid plaster set-up was moved in the capture volume to simulate walking and evaluate if inter-marker distances changed in comparison to static data. Dynamic displacement trials were then collected to measure changes in inter-marker distance due to vertical elongation of the gel liner. Static and dynamic inter-marker distances within day and across days confirmed the ability to accurately capture displacements using this new approach. These results encourage this novel method to be applied to a sample of amputee patients during walking to assess displacements and the distribution of the liner deformation within the socket. The ability to capture changes in deformation of the gel liner will provide new data that will enable clinicians and researchers to improve design and fit of the prosthesis so the incidence of pressure ulcers can be reduced. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Single-dose intra-alveolar chlorhexidine gel application, easier surgeries, and younger ages are associated with reduced dry socket risk.

    PubMed

    Haraji, Afshin; Rakhshan, Vahid

    2014-02-01

    Although dry socket (DS) is commonly investigated, many of its risk factors remain highly controversial. In addition, few studies are available to show the preventive effect of chlorhexidine gel on DS. Moreover, multivariable analyses of DS risk factors are scarce, and their interactions have not been assessed previously. Therefore, the simultaneous effect of chlorhexidine gel and 4 DS risk factors and their interactions were analyzed within a multivariable framework. Using a split-mouth randomized clinical trial design, the investigators enrolled a cohort of patients requiring extraction of 2 mandibular third molars. The primary predictor variable was extraction socket treatment status, classified as experimental or standard. Experimental treatment was the insertion of chlorhexidine gel (0.2%) into the extraction socket. Each patient had 1 third molar randomly selected as the treatment site. The contralateral third molar served as the control socket and was treated in the usual manner. The primary outcome variable was DS status, present or absent, assessed on postoperative day 3. Other study variables were categorized as demographic, smoking, and surgical difficulty according to the Pederson scale. Appropriate bivariate and multiple logistic regression statistics were used to measure the association between risk for DS and chlorhexidine gel use, age, gender, smoking, and surgical difficulty and their interactions (α = 0.05). The sample consisted of 90 bilateral extraction sockets in 45 patients (24 men; 21 smokers; mean age, 21.1 ± 2.7 yr). Regression analysis showed that when other factors and their interactions were controlled for, chlorhexidine gel application lowered the risk of DS (odds ratio [OR] = 0.05; P = .004). Increasing age (OR = 2.9; P = .030) was associated with an increased risk for DS. A similar association existed between increased difficulty level of extraction and DS risk (OR = 3.8; P = .051). The effect of gender was marginally significant (P

  12. Users' guide on socket heat fusion joining of polyethylene gas pipes. Volume 1. Topical report, September 1989-September 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pimputkar, S.M.; McCoy, J.K.; Stets, J.A.

    1991-03-01

    The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipemore » dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion joint samples in shear. The developed shear impact energy test data were found to be reliable measures of strength if the setups for conditions were meticulously identical. A parameter, termed the socket joining parameter, was found to characterize the joining conditions. It is a strong function of melt volume at the end of the heating phase, and physically, it is polyethylene transported parallel to the axis during insertion. The results for three resins are presented in the form of three nomographs. The nomographs may be used to select the required heater temperature or the heating time, for a given ambient temperature and a PE resin, to ensure a structurally sound socket heat fusion joint.« less

  13. Immediate Implants Placed in Fresh Sockets Associated with Periapical Pathology: A Split-Mouth Design and Survival Evaluation after 1-Year Follow-Up.

    PubMed

    Hita-Iglesias, Cristina; Sánchez-Sánchez, Francisco J; Montero, Javier; Galindo-Moreno, Pablo; Mesa, Francisco; Martínez-Lara, Ildefonso; Sánchez-Fernández, Elena

    2016-12-01

    To compare the immediate implant success rates between sites with chronic apical lesions and healthy sites in the same patients 1 year postdelayed loading. One hundred sixty-eight immediate implants were placed in sixty patients at upper incisor, canine, and premolar sites. A split-mouth design was used, placing a minimum of two implants, one in a fresh socket associated with chronic periapical disease, the average lesion size was larger than 4 mm and less than 8 mm (test group), and the other(s) in a healthy fresh socket (control group). Implant survival rate at 1 year postloading delayed was compared between the groups. The implant survival rate was 98.2% for the total sample (n = 168); out of the three implants lost, two were from the test group, and one was from the control group (in the same patient as one of the former). Among the surviving implants, five were also considered failures due to excessive bone loss (n = 3) and also because of the recurrence of the periapical lesions (n = 2). Survival rates were significantly lower in the test than control sites at 12 months postloading. Implant survival rates were significantly lower after the immediate implantation in postextraction sockets associated with chronic periapical disease (90.8%) than in healthy postextraction sockets (98.1%). © 2015 Wiley Periodicals, Inc.

  14. Development and acceptability testing of decision trees for self-management of prosthetic socket fit in adults with lower limb amputation.

    PubMed

    Lee, Daniel Joseph; Veneri, Diana A

    2018-05-01

    The most common complaint lower limb prosthesis users report is inadequacy of a proper socket fit. Adjustments to the residual limb-socket interface can be made by the prosthesis user without consultation of a clinician in many scenarios through skilled self-management. Decision trees guide prosthesis wearers through the self-management process, empowering them to rectify fit issues, or referring them to a clinician when necessary. This study examines the development and acceptability testing of patient-centered decision trees for lower limb prosthesis users. Decision trees underwent a four-stage process: literature review and expert consultation, designing, two-rounds of expert panel review and revisions, and target audience testing. Fifteen lower limb prosthesis users (average age 61 years) reviewed the decision trees and completed an acceptability questionnaire. Participants reported agreement of 80% or above in five of the eight questions related to acceptability of the decision trees. Disagreement was related to the level of experience of the respondent. Decision trees were found to be easy to use, illustrate correct solutions to common issues, and have terminology consistent with that of a new prosthesis user. Some users with greater than 1.5 years of experience would not use the decision trees based on their own self-management skills. Implications for Rehabilitation Discomfort of the residual limb-prosthetic socket interface is the most common reason for clinician visits. Prosthesis users can use decision trees to guide them through the process of obtaining a proper socket fit independently. Newer users may benefit from using the decision trees more than experienced users.

  15. Update of GRASP/Ada reverse engineering tools for Ada

    NASA Technical Reports Server (NTRS)

    Cross, James H., II

    1993-01-01

    The GRASP/Ada project (Graphical Representations of Algorithms, Structures, and Processes for Ada) successfully created and prototyped a new algorithmic level graphical representation for Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and, as a result, improve reliability and reduce costs. The emphasis was on the automatic generation of the CSD from Ada PDL or source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional pretty printed Ada source code. In Phase 1 of the GRASP/Ada project, the CSD graphical constructs were created and applied manually to several small Ada programs. A prototype CSD generator (Version 1) was designed and implemented using FLEX and BISON running under VMS on a VAX 11-780. In Phase 2, the prototype was improved and ported to the Sun 4 platform under UNIX. A user interface was designed and partially implemented using the HP widget toolkit and the X Windows System. In Phase 3, the user interface was extensively reworked using the Athena widget toolkit and X Windows. The prototype was applied successfully to numerous Ada programs ranging in size from several hundred to several thousand lines of source code. Following Phase 3,e two update phases were completed. Update'92 focused on the initial analysis of evaluation data collected from software engineering students at Auburn University and the addition of significant enhancements to the user interface. Update'93 (the current update) focused on the statistical analysis of the data collected in the previous update and preparation of Version 3.4 of the prototype for limited distribution to facilitate further evaluation. The current prototype provides the capability for the user to generate CSD's from Ada PDL or source code in a reverse engineering as well as forward engineering mode with a level of flexibility suitable for practical

  16. A frequency-based window width optimized two-dimensional S-Transform profilometry

    NASA Astrophysics Data System (ADS)

    Zhong, Min; Chen, Feng; Xiao, Chao

    2017-11-01

    A new scheme is proposed to as a frequency-based window width optimized two-dimensional S-Transform profilometry, in which parameters pu and pv are introduced to control the width of a two-dimensional Gaussian window. Unlike the standard two-dimensional S-transform using the Gaussian window with window width proportional to the reciprocal local frequency of the tested signal, the size of window width for the optimized two-dimensional S-Transform varies with the pu th (pv th) power of the reciprocal local frequency fx (fy) in x (y) direction. The paper gives a detailed theoretical analysis of optimized two-dimensional S-Transform in fringe analysis as well as the characteristics of the modified Gauss window. Simulations are applied to evaluate the proposed scheme, the results show that the new scheme has better noise reduction ability and can extract phase distribution more precise in comparison with the standard two-dimensional S-transform even though the surface of the measured object varies sharply. Finally, the proposed scheme is demonstrated on three-dimensional surface reconstruction for a complex plastic cat mask to show its effectiveness.

  17. "Virtual Cockpit Window" for a Windowless Aerospacecraft

    NASA Technical Reports Server (NTRS)

    Abernathy, Michael F.

    2003-01-01

    A software system processes navigational and sensory information in real time to generate a three-dimensional-appearing image of the external environment for viewing by crewmembers of a windowless aerospacecraft. The design of the particular aerospacecraft (the X-38) is such that the addition of a real transparent cockpit window to the airframe would have resulted in unacceptably large increases in weight and cost. When exerting manual control, an aircrew needs to see terrain, obstructions, and other features around the aircraft in order to land safely. The X-38 is capable of automated landing, but even when this capability is utilized, the crew still needs to view the external environment: From the very beginning of the United States space program, crews have expressed profound dislike for windowless vehicles. The wellbeing of an aircrew is considerably promoted by a three-dimensional view of terrain and obstructions. The present software system was developed to satisfy the need for such a view. In conjunction with a computer and display equipment that weigh less than would a real transparent window, this software system thus provides a virtual cockpit window. The key problem in the development of this software system was to create a realistic three-dimensional perspective view that is updated in real time. The problem was solved by building upon a pre-existing commercial program LandForm C3 that combines the speed of flight-simulator software with the power of geographic-information-system software to generate real-time, three-dimensional-appearing displays of terrain and other features of flight environments. In the development of the present software, the pre-existing program was modified to enable it to utilize real-time information on the position and attitude of the aerospacecraft to generate a view of the external world as it would appear to a person looking out through a window in the aerospacecraft. The development included innovations in realistic

  18. Scattering Response of Sucrose Clusters with Intense XFEL Pulses in Water Window

    NASA Astrophysics Data System (ADS)

    Ho, Phay; Benedikt Daurer, Benedikt; Bielecki, Johan; Hantke, Max; Maia, Filipe; Knight, Chris; Hajdu, Janos; Young, Linda; Bostedt, Christoph

    2017-04-01

    We present a combined experimental and theoretical study about the effects of non-linear x-ray ionization dynamics on the scattering response of molecular clusters in the soft x-ray regime that includes and goes beyond the water window. Nanosized sucrose clusters were irradiated with intense XFEL pulses (photon energy from 500 to 1500 eV and pulse duration of 180 fs). Surprisingly, the measured scattering signals near the oxygen K-edge in the water window are found to be substantially smaller than those at higher photon energies. We employ Monte-Carlo/Molecular Dynamics calculations to investigate the x-ray processes as a function of pulse parameters (photon energy, bandwidth and pulse duration) and cluster size. We demonstrate the important role of resonant excitation (RE) in the molecular scattering response in the water window. In particular, 1s ->2p RE cycling enabled in the oxygen atom/ion provide additional ionization pathways which, combined with the long pulse duration, lead to substantial reduction in scattering power of sugar clusters for photon energies just below the oxygen K-edge. Supported by the Chemical Sciences, Geosciences, and Biosciences Division, Office of Basic Energy Sciences, Office of Science, US Dept of Energy, Contract DE-AC02-06CH11357.

  19. Three-Dimensional Volumetric Changes in Severely Resorbed Alveolar Sockets After Ridge Augmentation with Bovine-Derived Xenograft and Resorbable Barrier: A Preliminary Study on CBCT Imaging.

    PubMed

    Manavella, Valeria; Romano, Federica; Corano, Lisa; Bignardi, Cristina; Aimetti, Mario

    The primary aim of the study was to describe a novel technique to evaluate volumetric hard tissue dimensional changes after ridge augmentation procedures. The secondary aim was to apply this newly developed measuring method to compromised alveolar sockets grafted with a slowly resorbing biomaterial covered with a collagen membrane. Eleven patients (6 men and 5 women, mean age 52.7 ± 8.3 years) requiring extraction of one hopeless tooth for severe periodontitis in the maxillary anterior area were consecutively treated with a ridge augmentation procedure. All experimental sockets showed advanced buccal bone plate deficiency and were grafted with deproteinized bovine bone mineral with 10% collagen covered with a collagen membrane. Sockets healed by secondary intention. Three-dimensional volumetric alveolar bone changes were calculated by superimposing cone beam computed tomography scans obtained before and 12 months after the augmentation procedure. After 12 months, the alveolar mineralized tissue filled 91.20% ± 7.96% of the maximum volume for regeneration. The augmentation procedure appeared not only to compensate for bone remodeling in most alveolar regions but also to repair a significant portion of the buccal wall. The most significant ridge width changes occurred 1 mm apical to the bone crest (2.33 ± 1.46 mm, P < .001). Within present limitations, this radiographic measuring methodology can be a useful tool to evaluate changes in socket volume. A ridge preservation technique performed with collagenated bovine bone and a collagen membrane was able to improve ridge shape and dimensions in compromised alveolar sockets.

  20. Acoustic window planning for ultrasound acquisition.

    PubMed

    Göbl, Rüdiger; Virga, Salvatore; Rackerseder, Julia; Frisch, Benjamin; Navab, Nassir; Hennersperger, Christoph

    2017-06-01

    Autonomous robotic ultrasound has recently gained considerable interest, especially for collaborative applications. Existing methods for acquisition trajectory planning are solely based on geometrical considerations, such as the pose of the transducer with respect to the patient surface. This work aims at establishing acoustic window planning to enable autonomous ultrasound acquisitions of anatomies with restricted acoustic windows, such as the liver or the heart. We propose a fully automatic approach for the planning of acquisition trajectories, which only requires information about the target region as well as existing tomographic imaging data, such as X-ray computed tomography. The framework integrates both geometrical and physics-based constraints to estimate the best ultrasound acquisition trajectories with respect to the available acoustic windows. We evaluate the developed method using virtual planning scenarios based on real patient data as well as for real robotic ultrasound acquisitions on a tissue-mimicking phantom. The proposed method yields superior image quality in comparison with a naive planning approach, while maintaining the necessary coverage of the target. We demonstrate that by taking image formation properties into account acquisition planning methods can outperform naive plannings. Furthermore, we show the need for such planning techniques, since naive approaches are not sufficient as they do not take the expected image quality into account.