Sample records for xcel bladeless trocar

  1. Trocar types in laparoscopy.

    PubMed

    la Chapelle, Claire F; Swank, Hilko A; Wessels, Monique E; Mol, Ben Willem J; Rubinstein, Sidney M; Jansen, Frank Willem

    2015-12-16

    Laparoscopic surgery has led to great clinical improvements in many fields of surgery; however, it requires the use of trocars, which may lead to complications as well as postoperative pain. The complications include intra-abdominal vascular and visceral injury, trocar site bleeding, herniation and infection. Many of these are extremely rare, such as vascular and visceral injury, but may be life-threatening; therefore, it is important to determine how these types of complications may be prevented. It is hypothesised that trocar-related complications and pain may be attributable to certain types of trocars. This systematic review was designed to improve patient safety by determining which, if any, specific trocar types are less likely to result in complications and postoperative pain. To analyse the rates of trocar-related complications and postoperative pain for different trocar types used in people undergoing laparoscopy, regardless of the condition. Two experienced librarians conducted a comprehensive search for randomised controlled trials (RCTs) in the Menstrual Disorders and Subfertility Group Specialised Register, Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, PsycINFO, CINAHL, CDSR and DARE (up to 26 May 2015). We checked trial registers and reference lists from trial and review articles, and approached content experts. RCTs that compared rates of trocar-related complications and postoperative pain for different trocar types used in people undergoing laparoscopy. The primary outcomes were major trocar-related complications, such as mortality, conversion due to any trocar-related adverse event, visceral injury, vascular injury and other injuries that required intensive care unit (ICU) management or a subsequent surgical, endoscopic or radiological intervention. Secondary outcomes were minor trocar-related complications and postoperative pain. We excluded trials that studied non-conventional laparoscopic incisions. Two review

  2. Numerical Study of Aeroacoustic Sound on Performance of Bladeless Fan

    NASA Astrophysics Data System (ADS)

    Jafari, Mohammad; Sojoudi, Atta; Hafezisefat, Parinaz

    2017-03-01

    Aeroacoustic performance of fans is essential due to their widespread application. Therefore, the original aim of this paper is to evaluate the generated noise owing to different geometric parameters. In current study, effect of five geometric parameters was investigated on well performance of a Bladeless fan. Airflow through this fan was analyzed simulating a Bladeless fan within a 2 m×2 m×4 m room. Analysis of the flow field inside the fan and evaluating its performance were obtained by solving conservations of mass and momentum equations for aerodynamic investigations and FW-H noise equations for aeroacoustic analysis. In order to design Bladeless fan Eppler 473 airfoil profile was used as the cross section of this fan. Five distinct parameters, namely height of cross section of the fan, outlet angle of the flow relative to the fan axis, thickness of airflow outlet slit, hydraulic diameter and aspect ratio for circular and quadratic cross sections were considered. Validating acoustic code results, we compared numerical solution of FW-H noise equations for NACA0012 with experimental results. FW-H model was selected to predict the noise generated by the Bladeless fan as the numerical results indicated a good agreement with experimental ones for NACA0012. To validate 3-D numerical results, the experimental results of a round jet showed good agreement with those simulation data. In order to indicate the effect of each mentioned parameter on the fan performance, SPL and OASPL diagrams were illustrated.

  3. Reverse Brayton Cycle with Bladeless Turbo Compressor for Automotive Environmental Cooling

    NASA Technical Reports Server (NTRS)

    Ganapathi, Gani B. (Inventor); Cepeda-Rizo, Juan (Inventor)

    2016-01-01

    An automotive cabin cooling system uses a bladeless turbocompressor driven by automobile engine exhaust to compress incoming ambient air. The compressed air is directed to an intercooler where it is cooled and then to another bladeless turbine used as an expander where the air cools as it expands and is directed to the cabin interior. Excess energy may be captured by an alternator couple to the expander turbine. The system employs no chemical refrigerant and may be further modified to include another intercooler on the output of the expander turbine to isolate the cooled cabin environment.

  4. 21 CFR 870.1390 - Trocar.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Trocar. 870.1390 Section 870.1390 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1390 Trocar. (a) Identification. A trocar is a...

  5. 21 CFR 870.1390 - Trocar.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Trocar. 870.1390 Section 870.1390 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1390 Trocar. (a) Identification. A trocar is a...

  6. Friction characteristics of trocars in laparoscopic surgery.

    PubMed

    Alazmani, Ali; Roshan, Rupesh; Jayne, David G; Neville, Anne; Culmer, Peter

    2015-04-01

    This article investigates the friction characteristics of the instrument-trocar interface in laparoscopic surgery for varying linear instrument velocities, trocar seal design and material, and trocar tilt. Furthermore, the effect of applying lubrication at the instrument-trocar seal interface on friction was studied. A friction testing apparatus was designed and built to characterise the resistance force at the instrument-trocar interface as a function of the instrument's linear movement in the 12-mm trocar (at constant velocity) for different design, seal material, and angle of tilt. The resistance force depended on the trocar seal design and material properties, specifically surface roughness, elasticity, hardness, the direction of movement, and the instrument linear velocity, and varied between 0.25 and 8 N. Lubricating the shaft with silicone oil reduced the peak resistance force by 75% for all trocars and eliminated the stick-slip phenomenon evident in non-lubricated cases. The magnitude of fluctuation in resistance force depends on the trocar design and is attributed to stick-slip of the sealing mechanism and is generally higher during retraction in comparison to insertion. Trocars that have an inlet seal made of rubber/polyurethane showed higher resistance forces during retraction. Use of a lubricant significantly reduced frictional effects. Comparisons of the investigated trocars indicate that a low friction port, providing the surgeon with improved haptic feedback, can be designed by improving the tribological properties of the trocar seal interface. © IMechE 2015.

  7. Influence of Coanda surface curvature on performance of bladeless fan

    NASA Astrophysics Data System (ADS)

    Li, Guoqi; Hu, Yongjun; Jin, Yingzi; Setoguchi, Toshiaki; Kim, Heuy Dong

    2014-10-01

    The unique Coanda surface has a great influence on the performance of bladeless fan. However, there is few studies to explain the relationship between the performance and Coanda surface curvature at present. In order to gain a qualitative understanding of effect of the curvature on the performance of bladeless fan, numerical studies are performed in this paper. Firstly, three-dimensional numerical simulation is done by Fluent software. For the purpose to obtain detailed information of the flow field around the Coanda surface, two-dimensional numerical simulation is also conducted. Five types of Coanda surfaces with different curvature are designed, and the flow behaviour and the performance of them are analyzed and compared with those of the prototype. The analysis indicates that the curvature of Coanda surface is strongly related to blowing performance, It is found that there is an optimal curvature of Coanda surfaces among the studied models. Simulation result shows that there is a special low pressure region. With increasing curvature in Y direction, several low pressure regions gradually enlarged, then begin to merge slowly, and finally form a large area of low pressure. From the analyses of streamlines and velocity angle, it is found that the magnitude of the curvature affects the flow direction and reasonable curvature can induce fluid flow close to the wall. Thus, it leads to that the curvature of the streamlines is consistent with that of Coanda surface. Meanwhile, it also causes the fluid movement towards the most suitable direction. This study will provide useful information to performance improvements of bladeless fans.

  8. Colorado Public Utility Commission's Xcel Wind Decision

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehr, R. L.; Nielsen, J.; Andrews, S.

    2001-09-20

    In early 2001 the Colorado Public Utility Commission ordered Xcel Energy to undertake good faith negotiations for a wind plant as part of the utility's integrated resource plan. This paper summarizes the key points of the PUC decision, which addressed the wind plant's projected impact on generation cost and ancillary services. The PUC concluded that the wind plant would cost less than new gas-fired generation under reasonable gas cost projections.

  9. Laparoscopic access with a visualizing trocar.

    PubMed

    Wolf, J S

    1997-01-01

    Although useful in most situations, there are several inherent disadvantages of the standard laparoscopic access techniques of Veress needle insertion and Hasson-type cannula placement. Veress needle placement may be hazardous in patients at high risk for intraabdominal adhesions and difficult in patients who are obese. The usual alternative, the Hasson-type cannula, often does not provide a good gas seal. As another option, the use of a visualizing trocar (OPTIVIEW) has proven to be effective in the initial experience at the University of Michigan. The inner trocar of the visualizing trocar is hollow except for a clear plastic conical tip with two external ridges. The trocar-cannula assembly is passed through tissue layers to enter the operative space under direct vision from a 10-mm zero-degree laparoscope placed into the trocar. Results suggest that this technique is an excellent alternative to Veress needle placement when laparoscopic access is likely to be hazardous or difficult.

  10. Trocar Port Hernias After Bariatric Surgery.

    PubMed

    Coblijn, Usha K; de Raaff, Christel A L; van Wagensveld, Bart A; van Tets, Willem F; de Castro, Steve M M

    2016-03-01

    Laparoscopic bariatric surgery is increasingly being performed worldwide. It is estimated that trocar port hernias occur more often in obese patients due to their obesity and because the ports are not closed routinely. The aim of the present study was to analyze the incidence, risk factors, and management of patients with trocar port hernias after laparoscopic bariatric surgery. All patients who were operated between 2006 and 2013 were included. During the study period, the trocar ports were not closed routinely. All patients who had any symptomatic abdominal wall hernia during follow-up were included. Overall, 1524 laparoscopic bariatric procedures were performed. There were 1249 female (82 %) and 275 male (18 %) patients. The mean age was 44 years, and median body mass index was 43 kg/m(2). Patients underwent laparoscopic Roux-en-Y gastric bypass (LRYGB) (n = 859), laparoscopic adjustable gastric banding (LAGB) (n = 364), laparoscopic sleeve gastrectomy (LSG) (n = 68), revisional surgery (n = 226), and other procedures (n = 7). Three hundred and one patients (20 %) had one or more postoperative complications and the overall mortality was 0.3 % (four patients). There were 14 patients (0.9 %) with an abdominal wall hernia, of which eight (0.5 %) had a trocar port hernia, three (0.2 %) an incisional hernia from other previous surgery, and three (0.2 %) an umbilical hernia. Gender, age, BMI, smoking, type II diabetes, procedure type, complications, and weight loss were not associated with the occurrence of abdominal wall hernias. Trocar port hernias after bariatric surgery occur seldom if the trocar port is not routinely closed.

  11. Trocar anterior chamber maintainer: Improvised infusion technique.

    PubMed

    Agarwal, Amar; Narang, Priya; Kumar, Dhivya A; Agarwal, Ashvin

    2016-02-01

    We present an improvised technique of infusion that uses a trocar cannula as an anterior chamber maintainer (ACM). Although routinely used in posterior segment surgery, the trocar cannula has been infrequently used in complex anterior segment procedures. The trocar ACM creates a transconjunctival biplanar wound of appropriate size that is self-sealing and overcomes the shortcomings of an ACM, such as spontaneous extrusion and forced introduction into the eye from variability in the size of the corneal paracentesis incision. Constant infusion inflow through the trocar ACM is used to maintain positive intraocular pressure through a self-sealing sclerotomy incision at the limbus. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Incidence of trocar site herniation following robotic gynecologic surgery.

    PubMed

    Clark, Leslie H; Soliman, Pamela T; Odetto, Diego; Munsell, Mark F; Schmeler, Kathleen M; Fleming, Nicole; Westin, Shannon N; Nick, Alpa M; Ramirez, Pedro T

    2013-11-01

    Trocar site herniation is a recognized complication of minimally invasive surgery, but published data on trocar site herniation after robotic surgery are scarce. We sought to determine the incidence of trocar site herniation in women undergoing robotic surgery for gynecologic disease. A retrospective review of robotic surgeries performed from January 1, 2006, through December 31, 2012, was conducted. Postoperative trocar site herniations were identified, along with time to presentation, location of herniation, and management. Patients were excluded if surgery was converted to laparotomy or traditional laparoscopy. The Wilcoxon rank-sum test was used to compare patients with and without herniation with respect to continuous variables, and Fisher's exact test was used to compare these 2 groups with respect to categorical variables. The study included 500 patients, 3 of whom experienced herniation at a single trocar site. The patients with and without herniation did not differ with respect to age, body mass index, smoking status, medical comorbidities, operating time, or estimated blood loss. All 3 herniations occurred at 12-mm trocar sites. Two herniations occurred at assistant port sites, and 1 occurred at the umbilical camera port site. The median time to herniation was 21 days (range, 8-38 days). One patient required immediate surgical intervention; the other 2 patients had conservative management. Trocar site herniation is a rare complication following robotic surgery. The most important risk factor for trocar site herniation appears to be larger trocar size, as all herniations occurred at 12-mm port sites. © 2013.

  13. A randomized, prospective study comparing the use of the missile trocar and the pyramidal trocar for laparoscopy access.

    PubMed

    Tansatit, Tanvaa; Wisawasukmongchol, Wirach; Bunyavejchevin, Suvit

    2006-07-01

    The missile trocar was developed for smooth abdominal penetration of the primary port. It contains a longitudinal tunnel connecting the abdominal cavity with the outside. To evaluate the efficacy of the missile trocar compared with the traditional method using the Veress needle. The times required to enter the abdominal cavity and the difficulty of the procedure were compared with the traditional Veress needle. A blind technique was used on 100 consecutive patients in a randomized fashion. The missile trocar technique took 2.7 +/- 1.6 minutes to perform compared with 3.9 +/- 1.3 min in the Veress needle group (p = 0.001), and the difficulty of the procedure was 2.1 +/- 1.9 cm (p = 0.433) rated from 10-cm scale. No carbon dioxide leakage or serious complications occurred in any patient. The results of the present study indicate that a long-tip missile trocar technique may be used safely when the technique is fully understood. This procedure is a relatively quick alternative approach for laparoscopy.

  14. Wind Energy Forecasting: A Collaboration of the National Center for Atmospheric Research (NCAR) and Xcel Energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parks, K.; Wan, Y. H.; Wiener, G.

    2011-10-01

    The focus of this report is the wind forecasting system developed during this contract period with results of performance through the end of 2010. The report is intentionally high-level, with technical details disseminated at various conferences and academic papers. At the end of 2010, Xcel Energy managed the output of 3372 megawatts of installed wind energy. The wind plants span three operating companies1, serving customers in eight states2, and three market structures3. The great majority of the wind energy is contracted through power purchase agreements (PPAs). The remainder is utility owned, Qualifying Facilities (QF), distributed resources (i.e., 'behind the meter'),more » or merchant entities within Xcel Energy's Balancing Authority footprints. Regardless of the contractual or ownership arrangements, the output of the wind energy is balanced by Xcel Energy's generation resources that include fossil, nuclear, and hydro based facilities that are owned or contracted via PPAs. These facilities are committed and dispatched or bid into day-ahead and real-time markets by Xcel Energy's Commercial Operations department. Wind energy complicates the short and long-term planning goals of least-cost, reliable operations. Due to the uncertainty of wind energy production, inherent suboptimal commitment and dispatch associated with imperfect wind forecasts drives up costs. For example, a gas combined cycle unit may be turned on, or committed, in anticipation of low winds. The reality is winds stayed high, forcing this unit and others to run, or be dispatched, to sub-optimal loading positions. In addition, commitment decisions are frequently irreversible due to minimum up and down time constraints. That is, a dispatcher lives with inefficient decisions made in prior periods. In general, uncertainty contributes to conservative operations - committing more units and keeping them on longer than may have been necessary for purposes of maintaining reliability. The downside is

  15. Internal air flow analysis of a bladeless micro aerial vehicle hemisphere body using computational fluid dynamic

    NASA Astrophysics Data System (ADS)

    Othman, M. N. K.; Zuradzman, M. Razlan; Hazry, D.; Khairunizam, Wan; Shahriman, A. B.; Yaacob, S.; Ahmed, S. Faiz; Hussain, Abadalsalam T.

    2014-12-01

    This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors and the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.

  16. Internal air flow analysis of a bladeless micro aerial vehicle hemisphere body using computational fluid dynamic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Othman, M. N. K., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Zuradzman, M. Razlan, E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Hazry, D., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my

    2014-12-04

    This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors andmore » the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.« less

  17. Trocars: Site Selection, Instrumentation, and Overcoming Complications.

    PubMed

    Gaunay, Geoffrey S; Elsamra, Sammy E; Richstone, Lee

    2016-08-01

    In recent years, laparoscopy and robot-assisted procedures have become more commonplace in urology. Incorporation of these techniques into clinical practice requires extensive knowledge of the surgical approaches and complex instrumentation unique to minimally invasive surgery. In this review, focus will be directed to laparoscopic trocars including differing subtypes, placement in select urologic procedures, and proper use with emphasis on the avoidance of complications. Differing methods for the development of pneumoperitoneum and the associated risks of each will be discussed. The aim of this article is to provide a complete review of laparoscopic trocar use for the practicing urologist.

  18. Randomized Prospective Trial on the Occurrence of Laparoscopic Trocar Site Hernias

    ClinicalTrials.gov

    2010-11-12

    The Aim of the Study is to Analyze the Incidence of Trocar Site Hernia (TSH); in Orifices Created by Trocars Measuring ≥10 mm in Diameter,; and to Determine Whether Closure of the External Fascial Layer Prevents; TSH and Potential Related Complications.

  19. 76 FR 21886 - Xcel Energy; Notice of Application of Recreational Resources Management Plan Update for the St...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-19

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 2056-049] Xcel Energy; Notice of Application of Recreational Resources Management Plan Update for the St. Anthony Falls Project and Soliciting Comments, Motions To Intervene, and Protests Take notice that the following hydroelectric application has been filed with the...

  20. Safer laparoscopic trocar entry: it's all about pressure.

    PubMed

    Tsaltas, Jim; Pearce, Scott; Lawrence, Anthony; Meads, Alan; Mezzatesta, Joseph; Nicolson, Scott

    2004-08-01

    This prospective observational study aimed to assess the feasibility of adapting peritoneal hyperdistention to 25 mmHg during laparoscopy in an Australian hospital environment. A total of 1150 consecutive diagnostic or operative laparoscopies were performed. All cases were monitored for early detection of untoward physiological changes. All patients had Veress needle insufflation with distension to 25 mmHg prior to insertion of the primary trocar. No patients experienced any surgical entry complications or adverse clinical effects noted during anaesthetic. The aim of the current study is to assess the feasibility and safety of increasing the peritoneal insufflation pressure to 25 mmHg for primary trocar insertion.

  1. Direct Trocar Insertion with Elevation of the Rectus Sheath in Bariatric Surgery: A Novel Technique.

    PubMed

    Habibi, Mani; Seyit, Hakan; Kones, Osman; Kartal, Bahadir; Alis, Halil

    2017-12-30

    Initial trocar entry, the first step in laparoscopic surgery, is associated with several complications. In morbidly obese patients, initial trocar placement is associated with a greater number of complications compared to non-obese patients. Materials and Surgical Technique. In this study, we describe our use of an initial trocar entry technique which is direct trocar insertion with elevation of the rectus sheath by a single Backhaus towel clamp and we would like to evaluate the sa fety and efficacy of its administration in bariatric surgery. Our results indicate that gaining initial trocar entry using our technique leads to successful laparoscopic bariatric surgery. Our technique is a safe, effective, and reliable first step in successful laparoscopic surgery for almost all patients, and is only contraindicated in patients with severe hepatomegaly.

  2. Intraoperative frozen pathology during robot-assisted laparoscopic radical prostatectomy: can ALEXIS™ trocar make it easy and fast?

    PubMed

    Almeida, Gilberto Laurino; Musi, Gennaro; Mazzoleni, Federica; Matei, Deliu Victor; Brescia, Antonio; Detti, Serena; de Cobelli, Ottavio

    2013-10-01

    To describe the first series of robot-assisted laparoscopic radical prostatectomy (RALP) using the ALEXIS™ trocar device when removal of the specimen is necessary for intraoperative frozen-section pathology. Consecutive RALP using the ALEXIS were prospectively catalogue. Perioperative data, including preoperative oncologic diagnosis, operative time, estimated blood loss (EBL), size of incision for umbilical trocar, complications related to trocar, and length of hospital stay, were analyzed. One hundred twenty-eight patients were analyzed. The mean operative time was 216 minutes, mean time to trocar placement was 4 minutes, and mean EBL was 172 mL. The incision size for a trocar was 2-3 cm in 117 patients and 1 incisional hernia was observed. The mean hospital stay was 3 days and mean follow-up was 4 months. The ALEXIS trocar provides an easy and fast intraoperative removal of the specimen for frozen pathology during RALP, even for large prostates. Safe and cosmetic results with a low intraoperative complication rate are acquired with the wound retractor.

  3. A rare case of acute presentation of trocar site hernia from robot-assisted laparoscopic partial nephrectomy.

    PubMed

    Ng, Zi Qin; Pemberton, Richard; Tan, Patrick

    2018-02-15

    Trocar site hernia is not a common acute complication encountered after robot-assisted surgery, especially in the urological cohort of patients. A few case reports of small bowel obstruction secondary to incarceration by trocar site hernia have been described in gynaecological surgery and prostatectomies. As the clinical presentation is non-specific, late diagnosis has significant implication on morbidity and mortality. Here, we present a rare case of a patient with recent robot-assisted laparoscopic partial nephrectomy for a renal cell carcinoma presented with features of impending bowel obstruction secondary to incarcerated small bowel in the trocar site. We also reviewed the literature focusing on clinical features of trocar site hernia and preventive measures.

  4. Ultrasound-guided Pleural Effusion Drainage With a Small Catheter Using the Single-step Trocar or Modified Seldinger Technique.

    PubMed

    Abusedera, Mohammad; Alkady, Ola

    2016-04-01

    Studies have shown that small-catheter pleural effusion drainage is safe and has a lower complication rate. Our objective was to evaluate the outcomes and the safety of the single-step trocar or the modified Seldinger technique. A total of 124 patients (83 men and 41 women), with mean age of 46±18 years and mean duration of drainage 5.3±2 days, were include in the study. The trocar technique was attempted in 201 (86.5%) cases, and the modified Seldinger technique was used in 38 (16.5%) cases. Technical success was obtained in 96% for the trocar technique and in 100% for the modified Seldinger technique. The procedure time for the trocar and the modified Seldinger techniques was approximately 7 and 12 minutes, respectively (P-value=0.02). The overall success rate was 72.9%. The success rate was highest for massive transudative effusions (98%) followed by malignant effusions (87%), and it was least for parapneumonic effusion/empyema (72 %). Pneumothorax occurred in 10.5% (n=4) for modified Seldinger versus 0.5% (n=1) (P=0.12) for trocar, whereas bleeding occurred in 0% for modified Seldinger and in 1% (n=2) for trocar (P=0.04). The single-step trocar technique was technically unsuccessful in 8 cases (7 had empyema with narrow intercostal spaces and one had kyphoscoliosis); technical success was achieved by using the modified Seldinger. Ultrasound-guided pleural effusion drainage by catheter insertion is a safe and effective procedure. The success rate is low when the effusion is loculated and septated. Both the trocar and the modified Seldinger techniques can be used. The trocar technique is faster and easier.

  5. Laparoscopic Removal of a Large Ovarian Mass Utilizing Planned Trocar Puncture

    PubMed Central

    2012-01-01

    Background: Large cystic ovarian masses pose technical challenges to the laparoscopic surgeon. Removing large, potentially malignant specimens must be done with care to avoid the leakage of cyst fluid into the abdominal cavity. Case: We present the case of a large ovarian cystic mass treated laparoscopically with intentional trocar puncture of the mass to drain and remove the mass. Discussion: Large cystic ovarian masses can be removed laparoscopically with intentional trocar puncture of the mass to facilitate removal without leakage of cyst fluid. PMID:22906344

  6. Percutaneous cystolithotripsy using self-retaining laparoscopic trocar for management of large bladder stones.

    PubMed

    Elbahnasy, Abdelhamid M; Farhat, Yasser A; Aboramadan, Ahmad R; Taha, Mohamed Rasheed

    2010-12-01

    Percutaneous endoscopic management of bladder stones is not new. The ideal technique to establish suprapubic access, however, is still not justified. In this study, we used the 12-mm self-retaining laparoscopic trocar for access during management of large bladder stones. With the patient in the lithotomy position, a 12-mm self-retaining laparoscopic trocar was inserted in a full bladder under cystoscopic visual control. A 28F nephroscope was used to fragment the stone using ultrasound and pneumoclast lithotriptors. After stone treatment, the trocar was left in place, and transurethral resection of the prostate (TURP) was completed when indicated. Both urethral and suprapubic catheters were left at the end of the procedure. Clinical examination, urinalysis, and ultrasonographic examination were routinely performed during follow-up visits. The mean stone size was 4.07 + 0.20 cm (2.8-6 cm). The average time for stone fragmentation was 32.78 + 2.16 minutes (range 8-53 min). A concomitant TURP was performed in 12 patients. The mean hospital stay was 2.56 + 0.15 days (range 1-4 days). All patients were stone free, and a total of six complications occurred, including extravasation, one patient; hematuria, two patients; and fever, three patients. All were treated conservatively. The mean follow-up time was 15.65 + 1.51 months (range 9-36 mos). Suprapubic percutaneous cystolithotripsy is a safe, minimally invasive alternative for management of large bladder stones. The use of a self-retaining trocar facilitates access and allows use of a large nephroscope for rapid fragmentation and extraction of the stone fragments. The presence of specific trocars for suprapubic access into the urinary bladder will encourage more transvesical end-laparoscopic procedures.

  7. A New CT-Guided Modified Trocar Technique for Drainage of Difficult Locations Abscesses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyng, Chiang J., E-mail: chiangjengtyng@gmail.com; Amoedo, Maurício K.; Bohrer, Yves

    PurposeComputed tomography (CT) is commonly used to guide drainage of deep-seated abdominal fluid collections. However, in some cases, these collections seem to be inaccessible due to surrounding organs or their being in difficult locations. The aim of this study is to describe a modified Trocar technique to drain collections in difficult locations, especially those in the subphrenic space, without passing through intervening organs.Materials and MethodsThis retrospective case series study describes seven inpatients who underwent CT-guided drainage using a modified Trocar technique for abscesses that are difficult to access percutaneously. All patients provided written informed consent prior to the procedure. Aftermore » placement of a 12–14F catheter inside the peritoneum, the Trocar stylet was removed so that the tip of the catheter became blunt and flexible to avoid injury to organs and structures in the catheter route, and the catheter was slowly advanced towards the collection using CT guidance and tactile sensation. After reaching the target, the stylet was reintroduced to enter the abscess wall.ResultsAll procedures were performed using an anterior abdominal wall access with adequate catheter positioning and resulted in clinical status improvement in the days after the drainage. No complications related to the procedure were identified in any of the patients.ConclusionsThe modified Trocar technique for percutaneous CT-guided drainage of abdominal abscesses may be feasible for lesions that are difficult to access with conventional methods.« less

  8. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.

    2012-04-15

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parametersmore » at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.« less

  9. Risks of Preterm Premature Rupture of Membranes and Preterm Birth Post Fetoscopy Based on Location of Trocar Insertion Site.

    PubMed

    Chmait, Ramen H; Chon, Andrew H; Korst, Lisa M; Llanes, Arlyn; Kontopoulos, Eftichia V; Quintero, Ruben A

    2018-07-01

     The objective of this study was to assess whether the location of the trocar insertion site for laser treatment of twin-twin transfusion syndrome was associated with preterm-premature rupture of membranes (PPROM) and preterm birth (PTB).  In this study trocar location was documented in the operating room. Lower uterine segment (LUS) location was defined as any insertion <10 cm vertically from the pubic symphysis. Lateral location was defined as ≥5 cm horizontally from the midline. Patient characteristics were tested against three outcomes: PPROM ≤ 21 days postoperative, PTB < 28 weeks, and PTB < 32 weeks. For each outcome, multiple logistic models were fitted to examine the effect of trocar location, controlling for potential risk factors.  A total of 743 patients were studied. Patients with LUS location were twice as likely as those with a more superior location to have PPROM ≤ 21 days (OR = 2.33, 1.12-4.83, p  = 0.0236). Patients with both a LUS and Lateral location were over six times more likely to have PPROM ≤ 21 days (OR = 6.66, 2.36-18.78, p  = 0.0003). Trocar insertion site was not associated with PTB.  We found that trocar insertion in the LUS, particularly the lateral LUS, was associated with an increased risk of PPROM. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. [Hernia surgery in urology. Part 2: parastomal, trocar and incisional hernias - fundamentals of clinical diagnostics and treatment].

    PubMed

    Franz, T; Schwalenberg, T; Dietrich, A; Müller, J; Stolzenburg, J-U

    2013-06-01

    Hernias are a common occurrence with a correspondingly huge clinical and economic impact on the healthcare system. Parastomal and trocar hernias are rare in routine urological work. The therapy of parastomal hernias remains problematic but basically the surgeon is able to use conventional techniques with suture repair or procedures with mesh implantation. The conventional parastomal hernia repair with mesh can be classified into sublay, onlay and intraperitoneal techniques. Furthermore, a relocation of the stoma is possible. Trocar hernias represent a rare but hazardous complication. Due to the increase in keyhole surgery there is also the danger of a rise in their occurrence. Incisional hernias occur frequently in patients who have undergone laparotomy and for repair different surgical techniques and types of meshes are available. This article presents an overview of the epidemiology, pathogenesis, clinical symptoms, diagnostic and therapy of parastomal, trocar and incisional hernias.

  11. Nonlinear model predictive control of a vortex-induced vibrations bladeless wind turbine

    NASA Astrophysics Data System (ADS)

    Azadi Yazdi, E.

    2018-07-01

    In this paper, a nonlinear model predictive controller (NMPC) is proposed for a vortex-induced vibrations bladeless wind turbine (BWT). The BWT consists of a long rigid cylinder mounted on a flexible beam. The nonlinear dynamic model of the transverse vibrations of the BWT is obtained under the fluctuating lift force due to periodically shedding vortices. The NMPC method is used to design a controller that achieves maximum energy production rate. It is observed that the power generation of the NMPC drops in high wind speeds due to a mismatch between the vortex shedding frequency and the structural natural frequency. Therefore, a secondary gain-scheduling (GS) controller is proposed to virtually increase the natural frequency of the structure to match the vortex shedding frequency for high winds. Although previous studies predicted the output power of the studied BWT to be less than 100 W, with the proposed GS-NMPC scheme the output power reaches the value of 1 kW. Therefore, the capability of the BWT as a renewable energy generation device was highly underestimated in the literature. The computed values of the aero-mechanical efficiency suggest the BWT as a major competitor to the conventional wind turbines.

  12. Safer trocar insertion for closed laparoscopic access: ex vivo assessment of an improved Veress needle.

    PubMed

    Nevler, Avinoam; Har-Zahav, Gil; Rosin, Danny; Gutman, Mordechai

    2016-02-01

    Laparoscopic surgery is widely practiced surgical technique in the modern surgical toolbox. The Veress needle insertion technique, while faster and easier, is associated with higher rates of iatrogenic complications (injury to internal organs, major blood vessels, etc.), morbidity and even mortality with a reported overall risk of 0.32% during surgical interventions. In order to increase the safety and ease of closed insertion technique, we designed and tested an improved prototype of the Veress needle. The new Veress needle includes a distal expandable portion that allows elevation of the abdominal wall and safe insertion of the first trocar over it. The needle was assessed by measurement of ease of insertion, ease of trocar advancement, associated tissue damage, device integrity and weight-bearing capacity on an ex vivo Gallus domesticus animal model: The prototype was tested over 20 times using different traction forces. The experiment was qualitatively repeated on an ex vivo porcine model. In the G. domesticus model, the improved needle supported forces of up to 5.75 kg F. No damage or mechanical malfunction was seen at any stage of the experiment. Needle penetration, ease of trocar insertion, system anchoring and weight-bearing capacity were rated (1-5) by four raters--mean 4.9 ± 0.31. Inter-rater agreement was high (free marginal κ 0.75). The porcine experiment revealed similar ease of use with neither complication nor damage to the abdominal wall. We believe that the new Veress system is easy to use, requires no additional training, non-inferior in its capabilities compared to the traditional Veress needle, with the advantage of improving the safety of the first trocar insertion phase of the operation.

  13. Rapid percutaneous nephrostomy catheter placement in neonates with the trocar technique.

    PubMed

    Ozbek, O; Kaya, H E; Nayman, A; Saritas, T B; Guler, I; Koc, O; Karakus, H

    2017-04-01

    The purpose of this study was to assess the efficacy of a modified percutaneous nephrostomy procedure for grade III-IV hydronephrosis in neonates. Eleven neonates (five girls, six boys) with a mean age of 13.7days±9.9 (SD) (range, 4-28days) with pronounced hydronephrosis had percutaneous nephrostomy using a modified procedure. In all patients, percutaneous nephrostomy was performed with a trocar catheter under ultrasound guidance and then the catheter was placed into the collecting system without prior dilatation. Technical success was achieved in all patients. There were no major procedure-related complications. There was no perirenal hematoma on control ultrasound examinations and no hematuria was observed after the procedure. The median drainage time was 75days (range: 42-120days). Two children had urinary tract infection, which was controlled by using antibiotics. The trocar nephrostomy is a practical and feasible method, which can be used for neonates with grade III-IV hydronephrosis. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  14. A technique for open trocar placement in laparoscopic surgery using the umbilical cicatrix tube.

    PubMed

    Lal, Pawanindra; Sharma, R; Chander, R; Ramteke, V K

    2002-09-01

    Increasingly the open method for placement of the initial or first trocar is replacing the conventional technique with the Veress needle. Indeed, it is preferred because it affords peritoneal access under direct vision. A number of methods have been described in the literature using a variety of approaches and different instruments. We describe a method of open trocar placement in the supra- or subumbilical region that follows a stepwise procedure and employs specific instruments sequentially, while utilizing the umbilical cicatrix pillar or tube. This technique has been done in 525 cases with no complications or port site hernias. This is a simple technique that is safe and easy to learn. It can be performed rapidly and is a reliable method for the insertion of the first port under vision.

  15. One-trocar-assisted pyeloplasty: An attractive alternative to open pyeloplasty.

    PubMed

    Marte, Antonio; Papparella, Alfonso

    2015-01-01

    To survey the effects of one-trocar-assisted pyeloplasty (OTAP) in the treatment of ureteropelvic junction obstruction (UPJO) in kids. Forty-four children (±3.5 years) were submitted to OTAP procedure. A flank incision under the XII rib was made, the Gerota's fascia was achieved and a balloon Hasson trocar with an operative telescope inserted for retroperitoneal access. The renal pelvis and ureter were isolated and exteriorised. Forty-two patients underwent Anderson-Hynes dismembered and one Fenger pyeloplasty . One patient was converted to an open procedure. Two patients presented an aberrant crossing vessel. In all patients, a double J stent was positioned. The operative time and length of stay (LOS) were evaluated. Renal scan and ultrasound (US) were utilised to evaluate the results from 6 to 12 months. OTAP was successful in all but 1 patient. Mean operative time and LOS were 128 min and 3,5 days. We had four operative complications (9.09%). The US and a nuclear scan confirmed the resolution of the UPJO in all patients except one with the Fenger pyeloplasty who had an open Anderson-Hynes. The combination of retroperitoneoscopic and open procedures for dismembered pyeloplasty offers a simple, time-saving method in a minimally invasive fashion with low morbidity for patients with UPJO.

  16. Comparison of Intraabdominal and Trocar Site Local Anaesthetic Infiltration on Postoperative Analgesia After Laparoscopic Cholecystectomy.

    PubMed

    Altuntaş, Gülsüm; Akkaya, Ömer Taylan; Özkan, Derya; Sayın, Mehmet Murat; Balas, Şener; Özlü, Elif

    2016-12-01

    This study aimed to compare the efficacy of local anaesthetic infiltration to trocar wounds and intraperitoneally on postoperative pain as a part of a multimodal analgesia method after laparoscopic cholecystectomies. The study was performed on 90 ASA I-III patients aged between 20 and 70 years who underwent elective laparoscopic cholecystectomy. All patients had the same general anaesthesia drug regimen. Patients were randomized into three groups by a closed envelope method: group I (n=30), trocar site local anaesthetic infiltration (20 mL of 0.5% bupivacaine); group II (n=30), intraperitoneal local anaesthetic instillation (20 mL of 0.5%) and group III (n=30), saline infiltration both trocar sites and intraperitoneally. Postoperative i.v. patient controlled analgesia was initiated for 24 h. In total, 4 mg of i.v. ondansetron was administered to all patients. Visual analogue scale (VAS), nausea and vomiting and shoulder pain were evaluated at 1., 2., 4., 8., 12., 24. hours. An i.v. nonsteroidal anti-inflammatory drug (NSAID) (50 mg of dexketoprofen) as a rescue analgesic was given if the VAS was ≥5. There were no statistical significant differences between the clinical and demographic properties among the three groups (p≥0.005). During all periods, VAS in group I was significantly lower than that in groups II and III (p<0.001). Among the groups, although there was no significant difference in nausea and vomiting (p=0.058), there was a significant difference in shoulder pain. Group III (p<0.05) had more frequent shoulder pain than groups I and II. The total morphine consumption was higher in groups II and III (p<0.001 vs p<0.001) than in group I. The requirement for a rescue analgesic was significantly higher in group III (p<0.05). Trocar site local anaesthetic infiltration is more effective for postoperative analgesia, easier to apply and safer than other analgesia methods. Morphine consumption is lesser and side effects are fewer; therefore, this method can be

  17. One-trocar-assisted pyeloplasty: An attractive alternative to open pyeloplasty

    PubMed Central

    Marte, Antonio; Papparella, Alfonso

    2015-01-01

    Background: To survey the effects of one-trocar-assisted pyeloplasty (OTAP) in the treatment of ureteropelvic junction obstruction (UPJO) in kids. Materials and Methods: Forty-four children (±3.5 years) were submitted to OTAP procedure. A flank incision under the XII rib was made, the Gerota's fascia was achieved and a balloon Hasson trocar with an operative telescope inserted for retroperitoneal access. The renal pelvis and ureter were isolated and exteriorised. Forty-two patients underwent Anderson-Hynes dismembered and one Fenger pyeloplasty. One patient was converted to an open procedure. Two patients presented an aberrant crossing vessel. In all patients, a double J stent was positioned. The operative time and length of stay (LOS) were evaluated. Renal scan and ultrasound (US) were utilised to evaluate the results from 6 to 12 months. Results: OTAP was successful in all but 1 patient. Mean operative time and LOS were 128 min and 3,5 days. We had four operative complications (9.09%). The US and a nuclear scan confirmed the resolution of the UPJO in all patients except one with the Fenger pyeloplasty who had an open Anderson-Hynes. Conclusions: The combination of retroperitoneoscopic and open procedures for dismembered pyeloplasty offers a simple, time-saving method in a minimally invasive fashion with low morbidity for patients with UPJO. PMID:26712293

  18. A novel procedure for introducing large sheet-type surgical material with a self-expanding origami structure using a slim trocar (chevron pleats procedure).

    PubMed

    Nakase, Yuen; Nakamura, Kei; Sougawa, Akira; Nagata, Tomoyuki; Mochizuki, Satoshi; Kitai, Shouzo; Inaba, Seishirou

    2017-09-01

    Large sheet-type surgical materials (e.g., absorbable hemostat, adhesion barrier membranes, and flat surgical mesh) are difficult to introduce into a corporeal cavity using a 5-mm trocar; however, laparoscopic surgeries that use mainly 5-mm trocars are increasing. Furthermore, it is necessary not only to introduce but also to secure the applied surgical material and expand it from the original surgical site. To address these challenges, we developed a novel procedure for introducing such surgical materials into a corporeal cavity using a 5-mm trocar and a self-expanding origami structure, called the "chevron pleats procedure (CPP)". We used CPP in 114 cases of laparoscopic surgery for gastrointestinal diseases. The chevron folding pattern is an excellent origami structure and compactly folds a large sheet of material for use with a slim trocar. Surgical materials were folded using a chevron pleats pattern and inserted into a novel, slim, long syringe-type device, which was made from a specially ordered precision polypropylene tube, for introduction into a corporeal cavity. When the surgical material was used, the end of the device was placed above the surgical site and the inner rod was pushed. The surgical material was securely injected and expanded over the surgical site. Surgical materials were introduced smoothly and securely using a 5-mm trocar to a site of intraoperative bleeding, the incisional surface of the liver, and defects of the abdominal wall or peritoneum. Efficient hemostasis was attained, the introduction and expansion of surgical mesh was made simpler, and the covering of defects of the peritoneum with adhesion barrier membranes, which is typically difficult during laparoscopic surgery, was easily performed. CPP is a basic utility procedure for introducing several sheet-type surgical materials into a corporeal cavity with a 5-mm trocar and might help ensure efficient and safe laparoscopic surgery.

  19. Trocar-site hernia at the 8-mm robotic port after robot-assisted laparoscopic prostatectomy: a case report and review of the literature.

    PubMed

    Tsu, James Hok-Leung; Ng, Ada Tsui-Lin; Wong, Jason Ka-Wing; Wong, Edmond Ming-Ho; Ho, Kwan-Lun; Yiu, Ming-Kwong

    2014-03-01

    Trocar-site hernia is an uncommon but serious complication after laparoscopic surgery as it frequently requires surgical intervention. We describe a 75-year-old man with Gleason score 4 + 3, clinical stage T1c prostate adenocarcinoma who underwent an uneventful robot-assisted transperitoneal laparoscopic radical prostatectomy. On post-operative day four, he developed symptoms of small bowel obstruction due to herniation and incarceration of the small bowels in a Spigelian-type hernia at the left lower quadrant 8-mm trocar site. Surgical exploration was performed via a mini-laparotomy to reduce the bowel and repair the fascial layers. A literature search was performed to review other cases of trocar-site hernia through the 8-mm robotic port after robot-assisted surgery and the suggested methods of prevention.

  20. Hybrid Single-Incision Laparoscopic Colon Cancer Surgery Using One Additional 5 mm Trocar.

    PubMed

    Kim, Hyung Ook; Choi, Dae Jin; Lee, Donghyoun; Lee, Sung Ryol; Jung, Kyung Uk; Kim, Hungdai; Chun, Ho-Kyung

    2018-02-01

    Single-incision laparoscopic surgery (SILS) is a feasible and safe procedure for colorectal cancer. However, SILS has some technical limitations such as collision between instruments and inadequate countertraction. We present a hybrid single-incision laparoscopic surgery (hybrid SILS) technique for colon cancer that involves use of one additional 5 mm trocar. Hybrid SILS for colon cancer was attempted in 70 consecutive patients by a single surgeon between August 2014 and July 2016 at Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine. Using prospectively collected data, an observational study was performed on an intention-to-treat basis. Hybrid SILS was technically completed in 66 patients, with a failure rate of 5.7% (4/70). One patient was converted to open surgery for para-aortic lymph node dissection. Another was converted to open surgery due to severe peritoneal adhesion. An additional trocar was inserted for adhesiolysis in the other two cases. Median lengths of proximal and distal margins were 12.8 cm (interquartile range [IQR], 10.0-18.6), and 8.2 cm (IQR, 5.5-18.3), respectively. Median total number of lymph nodes harvested was 24 (IQR, 18-33). Overall rate of postoperative morbidity was 12.9%, but there were no Clavien-Dindo grade III or IV complications. There was no postoperative mortality or reoperation. Median postoperative hospital stay was 6 days (IQR, 5-7). Hybrid SILS using one additional 5 mm trocar is a safe and effective minimally invasive surgical technique for colon cancer. Experienced laparoscopic surgeons can perform hybrid SILS without a learning curve based on the formulaic surgical techniques presented in this article.

  1. Three trocar laparoscopic Roux-en-y gastric bypass: a novel technique en route to the single-incision laparoscopic approach.

    PubMed

    Saber, Alan A; Elgamal, Mohamed H; El-Ghazaly, Tarek H; Elian, Alain R; Dewoolkar, Aditya V; Akl, Abir Hassan

    2010-01-01

    Laparoscopic Roux-en-Y gastric bypass is the gold standard bariatric procedure. Typically, the procedure necessitates five to seven small skin incisions for trocar placement. The senior author (AA Saber) has developed a three-trocar approach for laparoscopic Roux-en-Y gastric bypass. Sixteen patients underwent triple-incision laparoscopic Roux-en-Y gastric bypass between May 2009 and August 2009. The same surgeon performed all surgical interventions. The umbilicus was the main point of entry for all patients and the same operative technique and perioperative protocol were used in all patients. A total of sixteen triple-incision laparoscopic Roux-en-Y gastric bypasses were performed. The procedures were successfully performed in all patients. Mean operating time was 145.4 min. None of the patients required conversion to an open procedure. There were no mortalities or post-operative technical complications noted during the immediate post-operative period. Three trocar laparoscopic Roux-en-Y gastric bypass is safe, technically feasible and reproducible. This technique may be considered a "precursor" to single-incision laparoscopic Roux-en-Y gastric bypass. Copyright 2009 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  2. Two-Trocar Cholecystectomy by Strategic Laparoscopy for Improved Cosmesis (SLIC)

    PubMed Central

    Mirhaidari, Shayda; Pozsgay, Mark; Standerwick, Andrew; Bohon, Ashley; Zografakis, John G.

    2013-01-01

    Background and Objectives: Until the advent of single-incision laparoscopic surgery, few advances were aimed at improving cosmesis with laparoscopic cholecystectomy. Criticisms of the single-incision laparoscopic surgery technique include a larger incision and increased incidence of wound-related complications. We present our initial experience with a novel technique aimed at performing strategic laparoscopy for improved cosmesis (SLIC) for cholecystectomy. Methods: Twenty-five patients with biliary symptoms were selected for SLIC cholecystectomy. Access to the abdomen was obtained with a 5-mm optical trocar in the left upper quadrant and a 5-mm trocar in the umbilicus. Retraction was performed by a transabdominal suture in the dome of the gallbladder and a needlescopic grasper. Age, American Society of Anesthesiologists score, body mass index, operative time, length of stay, pathology results, and short-term complications at follow-up were prospectively recorded. Results: The 25 female patients had a mean age of 34.3 years and mean body mass index of 24 kg/m2. American Society of Anesthesiologists scores ranged from 1 to 3. The mean operative time was 51.3 minutes. Pathology revealed chronic cholecystitis in all patients. All procedures were performed on an outpatient basis. The only complication was one ultrasonography-documented deep vein thrombosis. All 25 planned SLIC cholecystectomies were successfully completed. Conclusions: SLIC cholecystectomy is feasible and safe. This technique decreases the cumulative incision length, as well as the number of incisions, leading to very desirable cosmetic results in patients with a favorable body habitus and surgical history. PMID:24398200

  3. Novel type of peritoneocentesis trocar-assisted distal ventriculoperitoneal shunt placement with supervision via a one-port laparoscope

    PubMed Central

    Wang, Guangming; Yu, Jinlu; Luan, Yongxin; Han, Yanwu; Fu, Shuanglin

    2017-01-01

    Ventriculoperitoneal shunts (VPS) are the primary treatment for hydrocephalus and are associated with a high risk of complications, specifically in patients who are obese or have abdominal adhesions or shunt revisions. The present study describes the use of a novel type of peritoneal catheter peritoneocentesis trocar insertion with the assistance of a one-port laparoscope. A total of 36 patients with hydrocephalus underwent this novel type of peritoneocentesis trocar-assisted VPS. The distal shunt catheter was placed into the right subdiaphragmatic space and the catheter was traversed through a single hole drilled through the liver falciform ligament. The duration of the laparoscopic surgery ranged from 6–18 min (mean 10.4±1.6 min). No shunt-related infections or catheter malfunctions or injuries to the intra-abdominal organs occurred. The total abdominal incision length was 1.0 cm (0.5+0.5 cm). No laparoscopy-related complications were observed during follow-up assessments. The novel approach used in the current study is very easy to perform, and this method may significantly reduce the risk of malfunction complications. The presented method also has the advantages of reduced trauma and a simpler surgery. The current study indicated that this simple, minimally invasive procedure was beneficial for patients with hydrocephalus, specifically in cases of patients with obesity, peritoneal adhesions or shunt revisions. PMID:29042927

  4. Novel type of peritoneocentesis trocar-assisted distal ventriculoperitoneal shunt placement with supervision via a one-port laparoscope.

    PubMed

    Wang, Guangming; Yu, Jinlu; Luan, Yongxin; Han, Yanwu; Fu, Shuanglin

    2017-10-01

    Ventriculoperitoneal shunts (VPS) are the primary treatment for hydrocephalus and are associated with a high risk of complications, specifically in patients who are obese or have abdominal adhesions or shunt revisions. The present study describes the use of a novel type of peritoneal catheter peritoneocentesis trocar insertion with the assistance of a one-port laparoscope. A total of 36 patients with hydrocephalus underwent this novel type of peritoneocentesis trocar-assisted VPS. The distal shunt catheter was placed into the right subdiaphragmatic space and the catheter was traversed through a single hole drilled through the liver falciform ligament. The duration of the laparoscopic surgery ranged from 6-18 min (mean 10.4±1.6 min). No shunt-related infections or catheter malfunctions or injuries to the intra-abdominal organs occurred. The total abdominal incision length was 1.0 cm (0.5+0.5 cm). No laparoscopy-related complications were observed during follow-up assessments. The novel approach used in the current study is very easy to perform, and this method may significantly reduce the risk of malfunction complications. The presented method also has the advantages of reduced trauma and a simpler surgery. The current study indicated that this simple, minimally invasive procedure was beneficial for patients with hydrocephalus, specifically in cases of patients with obesity, peritoneal adhesions or shunt revisions.

  5. Hemothorax caused by the trocar tip of the rod inserter after minimally invasive transforaminal lumbar interbody fusion: case report.

    PubMed

    Maruo, Keishi; Tachibana, Toshiya; Inoue, Shinichi; Arizumi, Fumihiro; Yoshiya, Shinichi

    2016-03-01

    Minimally invasive surgery (MIS) for transforaminal lumbar interbody fusion (MIS-TLIF) is widely used for lumbar degenerative diseases. In the paper the authors report a unique case of a hemothorax caused by the trocar tip of the rod inserter after MIS-TLIF. A 61-year-old woman presented with thigh pain and gait disturbance due to weakness in her lower right extremity. She was diagnosed with a lumbar disc herniation at L1-2 and the MIS-TLIF procedure was performed. Immediately after surgery, the patient's thigh pain resolved and she remained stable with normal vital signs. The next day after surgery, she developed severe anemia and her hemoglobin level decreased to 7.6 g/dl, which required blood transfusions. A chest radiograph revealed a hemothorax. A CT scan confirmed a hematoma of the left paravertebral muscle. A chest tube was placed to treat the hemothorax. After 3 days of drainage, there was no active bleeding. The patient was discharged 14 days after surgery without leg pain or any respiratory problems. This complication may have occurred due to injury of the intercostal artery by the trocar tip of the rod inserter. A hemothorax after spine surgery is a rare complication, especially in the posterior approach. The rod should be caudally inserted in the setting of the thoracolumbar spine.

  6. [Post-operative pain after ultrasound transversus abdominis plane block versus trocar site infiltration in laparoscopic nephrectomy: a prospective study].

    PubMed

    Araújo, Ana M; Guimarães, Joana; Nunes, Catarina S; Couto, Paula S; Amadeu, Eduarda

    Transversus abdominis plane (TAP) block is useful in reducing post-operative pain in laparoscopic nephrectomy compared to placebo. The purpose of this work is to compare post-operative pain and recovery after TAP block or trocar site infiltration (TSI) in this surgery. A prospective, single blinded study on patients scheduled for laparoscopic nephrectomy. Patients were assigned to two groups: TSI Group: trocar site infiltration at the end of surgery; TAP Group: unilateral ultrasound-guided TAP block after induction. Sevoflurane and remifentanil, in a target controlled infusion mode, were used for maintenance of general anesthesia. Before the end of surgery paracetamol, tramadol and morphine were administered. Visual analogue scale (VAS 0-100mm) at rest and with cough was applied in three moments: in recovery room (T1 at admission and T2 before discharge) and 24h after surgery (T3). Pain scores with incentive spirometer were also evaluated at T3. In recovery, morphine was administered as a rescue drug whenever VAS>30mm. Time to oral intake, chair sitting, ambulation and length of hospital stay were evaluated 24h after surgery. Student's t-test and Chi-square test, and linear regression models. A p-value<0.05 was considered significant. Data are presented as mean (SD). Forty patients were enrolled in the study. The primary outcome variable, VAS pain scores did not show a statistical significant difference between groups (p>0.05). VAS at rest (TAP vs. TSI groups) was: T1=33±29 vs. 39±32, T2=10±9 vs. 17±18 and T3=7±12 vs. 10±18. VAS with cough (TAP vs. TSI groups) was: T1=51±34 vs. 45±32, T2=24±24 vs. 33±23 and T3=20±23 vs. 23±23. VAS with incentive spirometer (TAP vs. TSI groups) was: T3=21±27 vs. 21±25. Intraoperative remifentanil consumption was similar between TAP (0.16±0.07mcg.kg -1 .min -1 ) and TSI (0.18±0.9mcg.kg -1 .min -1 ) groups. There were no differences in opioid consumption between TAP (4.4±3.49mg) and TSI (6.87±4.83mg) groups during

  7. About creation of machines for rock destruction with formation of apertures of various cross-sections

    NASA Astrophysics Data System (ADS)

    Zhukov, I. A.; Dvornikov, L. T.; Nikitenko, S. M.

    2016-04-01

    The article presents the results of the experimental research of the high strength rock destruction by a bladeless tool. Rational circuit designs of disposing of indenters in the impact part of the drill bits and a diamond tool are justified. New constructive solutions of reinforcing bladeless drill bits, which allow drilling blast-holes of the various cross-section, are shown.

  8. A novel method of personnel cooling in an operating theatre environment.

    PubMed

    Casha, Aaron R; Manché, Alexander; Camilleri, Liberato; Gauci, Marilyn; Grima, Joseph N; Borg, Michael A

    2014-10-01

    An optimized theatre environment, including personal temperature regulation, can help maintain concentration, extend work times and may improve surgical outcomes. However, devices, such as cooling vests, are bulky and may impair the surgeon's mobility. We describe the use of a low-cost, low-energy 'bladeless fan' as a personal cooling device. The safety profile of this device was investigated by testing air quality using 0.5- and 5-µm particle counts as well as airborne bacterial counts on an operating table simulating a wound in a thoracic operation in a busy theatre environment. Particle and bacterial counts were obtained with both an empty and full theatre, with and without the 'bladeless fan'. The use of the 'bladeless fan' within the operating theatre during the simulated operation led to a minor, not statistically significant, lowering of both the particle and bacterial counts. In conclusion, the 'bladeless fan' is a safe, effective, low-cost and low-energy consumption solution for personnel cooling in a theatre environment that maintains the clean room conditions of the operating theatre. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. 75 FR 19968 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-16

    ... Objection to State Operating Permit for Public Service Company of Colorado--Hayden Station AGENCY... of Colorado dba Xcel Energy (Xcel)--Hayden Power Station. Pursuant to section 505(b)(2) of the Clean.... Additionally, the final order for Public Service Company of Colorado--Hayden Power Station, is available...

  10. Globe stability during simulated vitrectomy with valved and non-valved trocar cannulas

    PubMed Central

    Abulon, Dina Joy; Charles, Martin; Charles, Daniel E

    2015-01-01

    Purpose To compare the effects of valved and non-valved cannulas on intraocular pressure (IOP), fluid leakage, and vitreous incarceration during simulated vitrectomy. Methods Three-port pars plana incisions were generated in six rubber eyes using 23-, 25-, and 27-gauge valved and non-valved trocar cannulas. The models were filled with air and IOP was measured. Similar procedures were followed for 36 acrylic eyes filled with saline solution. Vitreous incarceration was analyzed in eleven rabbit and twelve porcine cadaver eyes. Results In the air-filled model, IOP loss was 89%–94% when two non-valved cannulas were unoccupied versus 1%–5% when two valved cannulas were unoccupied. In the fluid-filled model, with non-valved cannulas, IOP dropped while fluid leaked from the open ports. With two open ports, the IOP dropped to 20%–30% of set infusion pressure, regardless of infusion pressure and IOP compensation. The IOP was maintained in valved cannulas when one or two ports were left open, regardless of IOP compensation settings. There was no or minimal fluid leakage through open ports at any infusion pressure. Direct microscopic analysis of rabbit eyes showed that vitreous incarceration was significantly greater with 23-gauge non-valved than valved cannulas (P<0.005), and endoscopy of porcine eyes showed that vitreous incarceration was significantly greater with 23-gauge (P<0.05) and 27-gauge (P<0.05) non-valved cannulas. External observation of rabbit eyes showed vitreous prolapse through non-valved, but not valved, cannulas. Conclusion Valved cannulas surpassed non-valved cannulas in maintaining IOP, preventing fluid leakage, and reducing vitreous incarceration during simulated vitrectomy. PMID:26445520

  11. Wear of Cutting Tool with Excel Geometry in Turning Process of Hardened Steel

    NASA Astrophysics Data System (ADS)

    Samardžiová, Michaela

    2016-09-01

    This paper deals with hard turning using a cutting tool with Xcel geometry. This is one of the new geometries, and there is not any information about Xcel wear in comparison to the conventional geometry. It is already known from cutting tools producers that using the Xcel geometry leads to higher quality of machined surface, perticularly surface roughness. It is possible to achieve more than 4 times lower Ra and Rz values after turning than after using conventional geometry with radius. The workpiece material was 100Cr6 hardened steel with hardness of 60 ± 1 HRC. The machine used for the experiment was a lathe with counter spindle DMG CTX alpha 500, which is located in the Centre of Excellence of 5-axis Machining at the Faculty of Materials Science and Technology in Trnava. The cutting tools made by CBN were obtained from Sandvik COROMANT Company. The aim of this paper is to investigate the cutting tool wear in hard turning process by the Xcel cutting tool geometry.

  12. Alternative Fuels Data Center

    Science.gov Websites

    Plug-In Electric Vehicle (PEV) Charging Rate Incentive - Xcel Energy Xcel Energy offers two rate options to qualified residential customers for charging PEVs. The Electric Vehicle (EV) Rate and the Time -of-Day Plan are optional and require a separate meter. For rate information, including how to qualify

  13. Potential risk of port-site adhesions in patients after laparoscopic myomectomy using radially expanding trocars.

    PubMed

    Kumakiri, Jun; Kikuchi, Iwaho; Kitade, Mari; Jinushi, Makoto; Shinjyo, Azusa; Takeda, Satoru

    2015-01-01

    To investigate the incidence of port-site adhesions following use of radially expanding trocars (RETs) at laparoscopic myomectomy by observation via second-look laparoscopy (SLL). In a retrospective study, data from patients who underwent SLL after laparoscopic myomectomy between January 2007 and June 2012 at Juntendo University Hospital, Tokyo, were assessed for the incidence of port-site adhesions forming below RET incisional scars when fascial and peritoneal defects had not been closed. During the study period, 554 patients underwent SLL, and 2176 incisional scars were examined. Adhesions were detected in 15 patients (2.8%); thus, the incidence of port-site adhesions under scars was 0.7% (15/2176). Among these 15 patients, the wounds with adhesions were located as follows: 6 (1.1%) under the umbilical scar, 5 (0.9%) under the right lower abdominal scar, 2 (0.4%) under the left upper abdominal scar, and 2 (0.4%) under the left lower abdominal scar. According to multiple regression analysis, the duration of laparoscopic myomectomy was positively associated with port-site adhesions (odds ratio, 1.79; 95% confidence interval, 1.09-2.94; P=0.02). The present data suggest that the incidence of port-site hernias and adhesions under RET incisional scars is low despite the non-closure of fascial and peritoneal defects. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  14. Single-Use Devices in Argentina: Cost Comparison Analysis of a "Re-Use" versus a "Single-Use" Policy for Trocars, Endocutters, Linear Cutters, and Harmonic Scalpels.

    PubMed

    Garay, Osvaldo Ulises; Elorrio, Ezequiel Garcia; Rodríguez, Viviana; Spira, Cintia; Augustovski, Federico; Pichon-Riviere, Andrés

    2017-12-01

    Re-use of medical devices labeled and marketed for single use only is a current practice around the world. To estimate the average difference per surgery in device-related costs (DRCs) when performed with single-use devices under a single-use policy (SUP) instead of a re-use policy (RP) from the perspective of the private health sector of Argentina. An analytical model was developed in Microsoft Excel and populated with data from a literature review, a Delphi-like panel, and local cost estimations. Four single-use devices were selected for analysis: plastic trocars, endocutters, linear cutters, and harmonic scalpels. DRCs were expressed in 2012 US dollars and divided into four cost categories: devices, adverse events, device failure, and surgical time extension. Outputs were expressed as DRCs per surgery under a SUP, under a RP, the difference between them expressed in US dollars (Diff_$), and the difference between them expressed as a percentage of surgery costs (Diff_%S). Deterministic and probabilistic sensitivity analyses were performed to analyze the impact of uncertainty on results. Expected DRCs per surgery were as follows: for trocars: SUP, US $424.6; RP, US $244.2; Diff_$, US $-180.4; and Diff_%S, -3.8%; for endocutters: SUP, US $1667.4; RP, US $1102.3; Diff_$, US $-565.1; and Diff_%S, -11.1%; for linear cutters: SUP, US $1228.1; RP, US $1045.9; Diff_$, US $-182.2; and Diff_%S, -3.4%; and for harmonic scalpels: SUP, US $1040.9; RP, US $292.4; Diff_$, US $-748.5; and Diff_%S, -14.8%. Sensitivity analyses showed results to be robust. RP was shown to be less costly in all devices and scenarios considered. Nevertheless, the real frequency of adverse events and their cost implications are still uncertain. More research is needed to assess the effectiveness and safety of these off-label policies. Copyright © 2017. Published by Elsevier Inc.

  15. Ultrasound-Guided Percutaneous Nephrostomy Performed on Neonates and Infants Using a "14-4" (Trocar and Cannula) Technique.

    PubMed

    Bas, Ahmet; Gülşen, Fatih; Emre, Senol; Samanci, Cesur; Uzunlu, Osman; Cantasdemir, Murat; Emir, Haluk; Numan, Furuzan

    2015-12-01

    Percutaneous nephrostomy (PCN) catheters are placed under combined ultrasound and fluoroscopic guidance in the interventional radiology suite and present unique challenges in neonates and infants. The purpose of this study was to demonstrate feasibility of PCN using a "14-4" (trocar and cannula) technique on neonates and infants. Between September 2009 and June 2014, data for 27 kidneys from consecutive 22 neonates or infants who underwent PCN catheter placement using the "14-4" technique were retrospectively analyzed. The median age at the time of placement of the PCN catheters was 11 days (range 5-300 days). There were 18 males and 4 females. All procedures were performed in the interventional radiology suite but without using fluoroscopy. Unilateral PCN was performed on 17 out of 22 patients, while bilateral drainage was performed on five patients. The technical success rate was 100%. The median duration of PCN catheter was 75 days (range 10-138 days). Minor macroscopic hematuria not requiring blood transfusion was present in two of the patients in which the hematuria lasted in 2 days. Placement of PCN catheters using a "14-4" technique with ultrasound as the sole imaging modality is a technically feasible and desirable option for neonates or infants. The technique obviates the need for ionizing radiation and potentially could be performed in the ultrasound room or even at the bedside.

  16. Port insertion for minimally invasive surgery: a report of practices in the Irish Republic.

    PubMed

    Harrington, Cuan M; Kavanagh, Dara O; Tierney, Sean; Deane, Richard; Hehir, Dermot

    2018-02-06

    With rapidly evolving surgical technologies, minimally invasive surgery (MIS) has become the mainstay approach for many surgeons worldwide. As laparoscopic surgery was introduced in Ireland over two decades ago, we may be encountering a higher prevalence of related complications. This study aimed to gather data pertaining to risk factors for port-site herniation in MIS. A 14-point anonymous questionnaire was distributed electronically between January and May 2017 to consultant and trainee laparoscopists in the Republic of Ireland. This survey related to laparoscopic volume and surgical approaches to laparoscopic port-sites. There were 172 eligible responses nationally. Approaches to peritoneal access included Hasson, veress (blind puncture) and SILS were 66.3, 32.6 and 1.2%, respectively. Senior surgeons and specialists in Obstetrics and Gynaecology (OBGYN) reported significantly higher utilisations of closed peritoneal access (p < 0.05). Of the participants, 119 (69.2%) reported using a bladeless trocar over a bladed type. Fascial closure was utilised in 94.2% of ≥ 10 mm and 2.3% of 5-mm ports using absorbable suture in 76.7%, non-absorbable suture in 14.5% and port closure devices in 8.7%. Perceptions of risk factors for PSH were not congruent with significant variations in responses between levels of expertise. This study demonstrates significant variations in laparoscopic port-site practices amongst surgeons nationally. The new era of practitioners may benefit from evidence-based technical workshops and guidelines to increase awareness and reduce potential complications.

  17. Energy Harvesting Systems and Methods of Assembling Same

    NASA Technical Reports Server (NTRS)

    Cepeda-Rizo, Juan (Inventor); Ganapathi, Gani B. (Inventor)

    2013-01-01

    A method of assembling an energy harvesting system is provided. The method includes coupling at least one energy storage device in flow communication with at least one apparatus that is configured to generate thermal energy and to transfer the thermal energy into at least one fluid stream. The energy storage device is configured to store the fluid stream. Moreover, the method includes coupling at least one fluid transfer device downstream from the energy storage device. The fluid transfer device receives the fluid stream from the energy storage device. A bladeless turbine is coupled in flow communication with the fluid transfer device, wherein the bladeless turbine receives the fluid stream to generate power.

  18. Development and Application of Advanced Weather Prediction Technologies for the Wind Energy Industry (Invited)

    NASA Astrophysics Data System (ADS)

    Mahoney, W. P.; Wiener, G.; Liu, Y.; Myers, W.; Johnson, D.

    2010-12-01

    Wind energy decision makers are required to make critical judgments on a daily basis with regard to energy generation, distribution, demand, storage, and integration. Accurate knowledge of the present and future state of the atmosphere is vital in making these decisions. As wind energy portfolios expand, this forecast problem is taking on new urgency because wind forecast inaccuracies frequently lead to substantial economic losses and constrain the national expansion of renewable energy. Improved weather prediction and precise spatial analysis of small-scale weather events are crucial for renewable energy management. In early 2009, the National Center for Atmospheric Research (NCAR) began a collaborative project with Xcel Energy Services, Inc. to perform research and develop technologies to improve Xcel Energy's ability to increase the amount of wind energy in their generation portfolio. The agreement and scope of work was designed to provide highly detailed, localized wind energy forecasts to enable Xcel Energy to more efficiently integrate electricity generated from wind into the power grid. The wind prediction technologies are designed to help Xcel Energy operators make critical decisions about powering down traditional coal and natural gas-powered plants when sufficient wind energy is predicted. The wind prediction technologies have been designed to cover Xcel Energy wind resources spanning a region from Wisconsin to New Mexico. The goal of the project is not only to improve Xcel Energy’s wind energy prediction capabilities, but also to make technological advancements in wind and wind energy prediction, expand our knowledge of boundary layer meteorology, and share the results across the renewable energy industry. To generate wind energy forecasts, NCAR is incorporating observations of current atmospheric conditions from a variety of sources including satellites, aircraft, weather radars, ground-based weather stations, wind profilers, and even wind sensors on

  19. Performance of a Dynamically Controlled Inverter in a Photovoltaic System Interconnected with a Secondary Network Distribution System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coddington, M. H.; Kroposki, B. D.; Basso, T.

    In 2008, a 300 kW{sub peak} photovoltaic (PV) system was installed on the rooftop of the Colorado Convention Center (CCC). The installation was unique for the electric utility, Xcel Energy, as it had not previously permitted a PV system to be interconnected on a building served by the local secondary network distribution system (network). The PV system was installed with several provisions; one to prevent reverse power flow, another called a dynamically controlled inverter (DCI), that curtails the output of the PV inverters to maintain an amount of load supplied by Xcel Energy at the CCC. The DCI system utilizesmore » current transformers (CTs) to sense power flow to insure that a minimum threshold is maintained from Xcel Energy through the network transformers. The inverters are set to track the load on each of the three phases and curtail power from the PV system when the generated PV system current reaches 95% of the current on any phase. This is achieved by the DCI, which gathers inputs from current transformers measuring the current from the PV array, Xcel, and the spot network load. Preventing reverse power flow is a critical technical requirement for the spot network which serve this part of the CCC. The PV system was designed with the expectation that the DCI system would not curtail the PV system, as the expected minimum load consumption was historically higher than the designed PV system size. However, the DCI system has operated many days during the course of a year, and the performance has been excellent. The DCI system at the CCC was installed as a secondary measure to insure that a minimum level of power flows to the CCC from the Xcel Energy network. While this DCI system was intended for localized control, the system could also reduce output percent if an external smart grid control signal was employed. This paper specifically focuses on the performance of the innovative design at this installation; however, the DCI system could also be used for

  20. Effectiveness of a reusable low-cost balloon trocar dissection device in the creation of preperitoneal space during endoscopic surgery. An experimental study in swine.

    PubMed

    Nácul, Miguel Prestes; Cavazzola, Leandro Totti; Loureiro, Marcelo de Paula; Bonin, Eduardo Aimoré; Ferreira, Paulo Roberto Walter

    2015-09-01

    To evaluate a new, low-cost, reusable balloon trocar device for dissection of the preperitoneal space during endoscopic surgery. Twenty swine (weight: 15-37 kg) were randomized to two groups, according to whether the preperitoneal space was created with a new balloon device manufactured by Bhio-Supply (group B) or with the commercially available OMSPDB 1000® balloon device manufactured by Covidien (group C). Quality and size of the created preperitoneal space, identification of anatomic structures, balloon dissection time, total procedure time, balloon resistance and internal pressure after insufflation with 300 mL of ambient air, balloon-related complications, and procedure cost were assessed. No significant differences in dissection time, total procedure time, or size of the created preperitoneal space were found between the groups. Balloons in group B had a significantly higher internal pressure compared to balloons in group C. None of the balloons ruptured during the experiment. Three animals in group C had balloon-related peritoneal lacerations. Despite a higher individual device cost, group B had a lower procedure cost over the entire experiment. The new balloon device is not inferior to the commercially available device in terms of the safety and effectiveness for creating a preperitoneal space in swine.

  1. 76 FR 28761 - Combined Notice of Filings #2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-18

    ... following PURPA 210(m)(3) filings: Docket Numbers: QM11-3-000. Applicants: Xcel Energy Services Inc...: Application to Terminate Mandatory PURPA Purchase Obligation of Northern States Power Company, a Minnesota...

  2. Energy Systems Integration Partnerships: NREL + Panasonic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berdahl, Sonja E

    In collaboration with Panasonic Enterprise Solutions Company, Xcel Energy, land developer L.C. Fulenwider, and the City and County of Denver, NREL is developing a zero-energy transit-oriented campus at the Denver International Airport's Pena Station.

  3. Pushing the envelope: laparoscopy and primary anastomosis are technically feasible in stable patients with Hinchey IV perforated acute diverticulitis and gross faeculent peritonitis.

    PubMed

    Di Saverio, Salomone; Vennix, Sandra; Birindelli, Arianna; Weber, Dieter; Lombardi, Raffaele; Mandrioli, Matteo; Tarasconi, Antonio; Bemelman, Willem A

    2016-12-01

    Modern management of severe acute complicated diverticulitis continues to evolve towards more conservative and minimally invasive strategies. Although open sigmoid colectomy with end colostomy remains the most commonly used procedure for the treatment of perforated diverticulitis with purulent/faeculent peritonitis, recent major advances challenged this traditional approach, including the increasing attitude towards primary anastomosis as an alternative to end colostomy and use of laparoscopic approach for urgent colectomy. Provided an accurate patients selection, having the necessary haemodynamic stability, pneumoperitoneum is established with open Hasson technique and diagnostic laparoscopy is performed. If faeculent peritonitis (Hinchey IV perforated diverticulitis) is found, laparoscopy can be continued and a further three working ports are placed using bladeless trocars, as in traditional laparoscopic sigmoidectomy, with the addition of fourth trocar in left flank. The feacal matter is aspirated either with large-size suction devices or, in case of free solid stools, these can be removed with novel application of tight sealing endobags, which can be used for scooping the feacal content out and for its protected retrieval. After decontamination, a sigmoid colectomy is performed in the traditional laparoscopic fashion. The sigmoid is fully mobilised from the retroperitoneum, and mesocolon is divided up to the origin of left colic vessels. Whenever mesentery has extremely inflamed and thickened oedematous tissues, an endostapler with vascular load can be used to avoid vascular selective ligatures. Splenic flexure should be appropriately mobilised. The specimen is extracted through mini-Pfannenstiel incision with muscle splitting technique. Transanal colo-rectal anastomosis is fashioned. Air-leak test must be performed and drains placed where appropriate. The video shows operative technique for a single-stage, entirely laparoscopic, washout and sigmoid colectomy

  4. Development and initial porcine and cadaver experience with three-dimensional printing of endoscopic and laparoscopic equipment.

    PubMed

    del Junco, Michael; Okhunov, Zhamshid; Yoon, Renai; Khanipour, Ramtin; Juncal, Samuel; Abedi, Garen; Lusch, Achim; Landman, Jaime

    2015-01-01

    Recent advances in three-dimensional (3D) printing technology have made it possible to print surgical devices. We report our initial experience with the printing and deployment of endoscopic and laparoscopic equipment. We created computer-aided designs for ureteral stents and laparoscopic trocars using SolidWorks. We developed three generations of stents, which were printed with an Objet500 Connex printer, and a fourth generation was printed with an EOSINT P395 printer. The trocars were printed with an Objet30 Pro printer. We deployed the printed stents and trocars in a female cadaver and in vivo porcine model. We compared the printed trocars to two standard trocars for defect area and length using a digital caliper. Paired T-tests and ANOVA were used to test for statistical difference. The first two generations of stents (7F and 9F) were functional failures as their diminutive inner lumen failed to allow the passage of a 0.035 guidewire. The third generation 12F stent allowed passage of a 0.035 guidewire. The 12F diameter limited its deployment, but it was introduced in a cadaver through a ureteral access sheath. The fourth-generation 9F stents were printed and deployed in a porcine model using the standard Seldinger technique. The printed trocars were functional for the maintenance of the pneumoperitoneum and instrument passage. The printed trocars had larger superficial defect areas (p<0.001) and lengths (p=0.001) compared to Karl Storz and Ethicon trocars (29.41, 18.06, and 17.22 mm(2), respectively, and 14.29, 11.39, and 12.15 mm, respectively). In this pilot study, 3D printing of ureteral stents and trocars is feasible, and these devices can be deployed in the porcine and cadaver models. Three-dimensional printing is rapidly advancing and may be clinically viable in the future.

  5. Development and Initial Porcine and Cadaver Experience with Three-Dimensional Printing of Endoscopic and Laparoscopic Equipment

    PubMed Central

    del Junco, Michael; Okhunov, Zhamshid; Yoon, Renai; Khanipour, Ramtin; Juncal, Samuel; Abedi, Garen; Lusch, Achim

    2015-01-01

    Abstract Introduction: Recent advances in three-dimensional (3D) printing technology have made it possible to print surgical devices. We report our initial experience with the printing and deployment of endoscopic and laparoscopic equipment. Materials and Methods: We created computer-aided designs for ureteral stents and laparoscopic trocars using SolidWorks. We developed three generations of stents, which were printed with an Objet500 Connex printer, and a fourth generation was printed with an EOSINT P395 printer. The trocars were printed with an Objet30 Pro printer. We deployed the printed stents and trocars in a female cadaver and in vivo porcine model. We compared the printed trocars to two standard trocars for defect area and length using a digital caliper. Paired T-tests and ANOVA were used to test for statistical difference. Results: The first two generations of stents (7F and 9F) were functional failures as their diminutive inner lumen failed to allow the passage of a 0.035 guidewire. The third generation 12F stent allowed passage of a 0.035 guidewire. The 12F diameter limited its deployment, but it was introduced in a cadaver through a ureteral access sheath. The fourth-generation 9F stents were printed and deployed in a porcine model using the standard Seldinger technique. The printed trocars were functional for the maintenance of the pneumoperitoneum and instrument passage. The printed trocars had larger superficial defect areas (p<0.001) and lengths (p=0.001) compared to Karl Storz and Ethicon trocars (29.41, 18.06, and 17.22 mm2, respectively, and 14.29, 11.39, and 12.15 mm, respectively). Conclusions: In this pilot study, 3D printing of ureteral stents and trocars is feasible, and these devices can be deployed in the porcine and cadaver models. Three-dimensional printing is rapidly advancing and may be clinically viable in the future. PMID:24983138

  6. 77 FR 21978 - Notice of Commission Staff Attendance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-12

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Commission Staff Attendance The Federal Energy Regulatory Commission (Commission) hereby gives notice that members of the... Transmission LLC. Docket No. EL12-28 Xcel Energy. Docket No. ER12-1357 Louisville Gas and Electric Company...

  7. 77 FR 10737 - Combined Notice of Filings #2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-23

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 2 Take notice that the Commission received the following electric rate filings: Docket Numbers: ER12-1075-000 Applicants: Xcel Energy Services Inc. Description: Notice of Termination of Service Schedule A to the...

  8. 75 FR 63212 - Northern States Power Company-Minnesota; Notice of Withdrawal of Application for Amendment to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-14

    ... NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-282 and 50-306; NRC-2010-0325] Northern States Power Company--Minnesota; Notice of Withdrawal of Application for Amendment to Facility Operating License The U... Company, a Minnesota corporation (the licensee), doing business as Xcel Energy, to withdraw its January 27...

  9. 75 FR 61726 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-06

    ... Colorado. Description: Xcel Energy submits a fully-executed Offer of Settlement and Settlement Agreement... Tuesday, October 12, 2010. Docket Numbers: ER10-2804-000. Applicants: Public Service Company of Colorado. Description: Public Service Company of Colorado submits tariff filing per 35.37: 2010--09--21 PSCo Triennial...

  10. 75 FR 8691 - Combined Notice of Filings # 3

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-25

    ..., 2010. Take notice that the Commission received the following electric rate filings: Docket Numbers.... Applicants: Xcel Energy Services Inc. Description: Northern States Power Company et al submits Original Sheet 1 et al to FERC Electric Tariff, Original Volume 3--FERC Electric Rate Schedule 280-NSP. Filed Date...

  11. 75 FR 53374 - Notice of Rail Energy Transportation Advisory Committee Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-31

    ... the offices of Xcel Energy, 1800 Larimer Street, 2nd Floor, Conference Center, Denver, Colorado 80202... impaired is available through the Federal Information Relay Service (FIRS) at: (800) 877-8339..., and rail service metrics. The meeting, which is open to the public, will be conducted pursuant to...

  12. 78 FR 12358 - Cardinal Health, Financial Shared Services West, Including On-Site Leased Workers From Aerotek...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-22

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,253] Cardinal Health, Financial Shared Services West, Including On- Site Leased Workers From Aerotek, eXcel Staffing, Experis Finance (Manpower), Ricoh, USA, Dawson Creative, Mergis Group and Tailored Management, Albuquerque, NM; Amended Certification Regarding Eligibility To...

  13. SPIDER ® sleeve gastrectomy--a new concept in single-trocar bariatric surgery: initial experience and technical details.

    PubMed

    Noel, P; Nedelcu, M; Gagner, M

    2014-04-01

    Single port instrument delivery extended reach (SPIDER(®)) surgical system is a revolutionary surgical platform that allows triangulation of the surgical instruments while eliminating the crossing of instruments, the problematic characteristic of single access laparoscopic surgery. The purpose of this study was to analyze our initial experience with SPIDER(®) sleeve gastrectomy and to present the technical details of this new minimally invasive approach, performed in ten patients at the La Casamance Private Hospital between November 2012 and April 2013. All patients were reviewed at scheduled post-operative consultations at 1, 3 and 6 months. In addition to clinical examination, the post-operative consultation at one month also included a satisfaction survey using the Moorehead-Ardelt questionnaire. An initial series of ten sleeve gastrectomies were performed in female patients with a mean age of 41.5 years (range: 2-52). The mean BMI was 40.11 (range: 37.25-44.3). The intervention was performed through a single trocar in all patients with no "conversion" to classic laparoscopy or open surgery. The mean operative time was 61 ± 15.22 minutes (SD=standard deviation) (range: 43-96 min). The mean BMI at one month was 35.5 (SD:± 3.58, SEM: ± 1.13) (SEM=standard error of mean) with an average percentage of excess weight loss (%EWL) of 32.9% (SD:± 8.56%, SEM:± 2.71%). The mean BMI at three months was 32.4 (SD: ± 2.78, SEM: ± 0.88) with an average %EWL of 52.7% (SD: ± 8.64%, SEM: ± 2.73%). The mean BMI at six months was 29.9 (SD:± 2.60, SEM: ± 0.98) with a mean %EWL of 68.8% (SD: ± 8.38%, SEM:± 3.17%). Complete remission of co-morbid conditions was observed in four patients, improvement in three others, and no change in a single patient. The mean duration of hospitalization was 3.1 days. The mean follow-up period was 161 days (SD:± 57.4 days, range: 90-243 days). There was no mortality and no intra-operative and post-operative complications were noted. The

  14. NREL: News - Students Recognized for Creativity during Energy Education

    Science.gov Websites

    Middle School, third place; Horizon Community Middle School's car, "Bueblur," fourth place; and technology, craftsmanship and innovation were given to teams from Moore Middle School, first place; Manning Army, Xcel Energy and the Kaiser-Hill Company. As part of the K'NEX Design Contest, nine middle-school

  15. Laparoscopic radical nephrectomy: incorporating advantages of hand assisted and standard laparoscopy.

    PubMed

    Ponsky, Lee E; Cherullo, Edward E; Banks, Kevin L W; Greenstein, Marc; Streem, Stevan B; Klein, Eric A; Zippe, Craig D

    2003-06-01

    We present an approach to laparoscopic radical nephrectomy and intact specimen extraction, which incorporates hand assisted and standard laparoscopic techniques. A refined approach to laparoscopic radical nephrectomy is described and our experience is reviewed. A low, muscle splitting Gibson incision is made just lateral to the rectus muscle and the hand port is inserted. A trocar is placed through the hand port and pneumoperitoneum is established. With the laparoscope in the hand port trocar 2 additional trocars are placed under direct vision. The laparoscope is then repositioned through the middle trocar and standard laparoscopic instruments are used through the other 2 trocars including the one in the hand port. If at any time during the procedure the surgeon believes the hand would be useful or needed, the trocar is removed from the hand port and the hand is inserted. This approach has been applied to 7 patients. Mean estimated blood loss was 200 cc (range 50 to 300) and mean operative time was 276.7 minutes (range 247 to 360). Mean specimen weight was 767 gm. (range 538 to 1,170). Pathologically 6 specimens were renal cell carcinoma (grades 2 to 4) and 1 was oncocytoma. Mean length of hospital stay was 3.71 days (range 2 to 7). There were no major complications. We believe that this approach enables the surgeon to incorporate the advantages of the hand assisted and standard laparoscopic approaches.

  16. Assessment of two methods of gastric decompression for the initial management of gastric dilatation-volvulus.

    PubMed

    Goodrich, Z J; Powell, L L; Hulting, K J

    2013-02-01

    To assess gastric trocarization and orogastric tubing as a means of gastric decompression for the initial management of gastric dilatation-volvulus. Retrospective review of 116 gastric dilatation-volvulus cases from June 2001 to October 2009. Decompression was performed via orogastric tubing in 31 dogs, gastric trocarization in 39 dogs and a combination of both in 46 dogs. Tubing was successful in 59 (75·5%) dogs and unsuccessful in 18 (23·4%) dogs. Trocarization was successful in 73 (86%) dogs and unsuccessful in 12 (14%) dogs. No evidence of gastric perforation was noted at surgery in dogs undergoing either technique. One dog that underwent trocarization had a splenic laceration identified at surgery that did not require treatment. Oesophageal rupture or aspiration pneumonia was not identified in any dog during hospitalization. No statistical difference was found between the method of gastric decompression and gastric compromise requiring surgical intervention or survival to discharge. Orogastric tubing and gastric trocarization are associated with low complication and high success rates. Either technique is an acceptable method for gastric decompression in dogs with gastric dilatation-volvulus. © 2013 British Small Animal Veterinary Association.

  17. NREL: News - Customer Choice Would Advance Renewable Energy

    Science.gov Websites

    Awarded Xcel Energy Contracts for Renewable Research Golden, Colo., Jan. 03, 2002 The U.S . Department of Energy's National Renewable Energy Laboratory (NREL) has been selected to perform three research projects, worth $2.8 million, as part of a program to advance renewable energy that is funded by

  18. Xcel Energy Comanche Station: Pueblo, Colorado (Data)

    DOE Data Explorer

    Stoffel, T.; Andreas, A.

    2007-06-20

    A partnership with industry and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  19. 77 FR 25162 - Golden Spread Electric Cooperative, Inc. v. Southwestern Public Service Company; Notice of Complaint

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-27

    ... April 20, 2012, pursuant to sections 201, 206, and 306 of the Federal Power Act, 16 U.S.C. 824, 824e and... rate of Replacement Power Sales Agreement (RPSA) by and between Golden Spread and SPS and that the formula rate of the Xcel Joint Energy Open Access Tariff applicable to pricing of transmission service...

  20. 78 FR 46332 - Golden Spread Electric Cooperative, Inc. v. Southwestern Public Service Company; Notice of Complaint

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-31

    ... 309 of the Federal Power Act, 16 U.S.C. 824, 824e, and 825e (2013) and Rule 206 of the Federal Energy...), alleging that the formula rate Replacement Power Sales Agreement (RPSA) by and between Golden Spread and SPS and the formula rate of the Xcel Joint Energy Open Access Tariff applicable to pricing of...

  1. Prospective, randomized, controlled trial comparing a tissue adhesive (Dermabond™) with adhesive strips (Steri-Strips™) for the closure of laparoscopic trocar wounds in children.

    PubMed

    Romero, P; Frongia, G; Wingerter, S; Holland-Cunz, S

    2011-05-01

    4 methods are used in pediatric laparoscopic surgery to close trocar wounds. While tissue adhesives or adhesive strips have been shown to produce fewer wound complications and a better cosmetic result compared to trans- or only subcutaneous sutures, the choice of technique is still often based on the surgeon's personal experience. Thus, the objective of this trial was to assess the impact of tissue adhesives (Dermabond™) compared to adhesive strips (Steri-Strip™) on potential complications of wound healing, wound pain, cosmetic outcome, and patient satisfaction after laparoscopic appendectomy in children. 49 patients undergoing laparoscopic appendectomy were enrolled in this prospective randomized trial. In every patient, two 5-mm and one 10-mm port-site incision was closed either with Dermabond™ or Steri-Strip™ after placing subcuticular absorbable sutures (4-0 Vicryl™). Postoperative complications, pain, and patient satisfaction with scars were evaluated at follow-up on day 10 and day 90 after the operation using a questionnaire and a visual analogue scale (VAS). Photographs of scars taken on day 90 were evaluated on a VAS by 2 pediatric surgeons blinded to the closure method used. According to the surgeons' evaluation of the cosmetic outcome, a significant difference between the 2 groups with regard to the cosmetic score was found on day 90 of follow-up, favoring Steri-Strip™ wound closure (p < 0.05). On day 10 and 90 there were no statistical differences between the 2 methods as regards the result of patient evaluations (p > 0.05). Only one wound infection (4%) was observed in the Steri-Strip™ group (n = 25) on day 10. At follow-up on day 90 two patients (9.1%) in the Dermabond™ group and one (4.8%) in the Steri-strip™ group complained of wound pain (p = 0.52). Both tissue adhesives and adhesive strips are excellent "no needle" alternatives for the closure of laparoscopic port-site incisions in children. As regards cosmetic outcome, Steri

  2. The suprapubic approach for laparoscopic appendectomy.

    PubMed

    Kollmar, O; Z'graggen, K; Schilling, M K; Buchholz, B M; Büchler, M W

    2002-03-01

    Because it produces superior cosmetic results, patients prefer laparoscopic appendectomy over open appendectomy. We developed two alternative laparoscopic routes of access to the abdominal cavity for appendectomy that use suprapubic incisions placed below the line of pubic hair. We then compared the results for these three different modes of access. Operative characteristics, morbidity, outcome, and patient preference regarding three different approaches to laparoscopic appendectomy were compared in a retrospective study. In addition, a group of 24 healthy women were surveyed by questionnaire about their preferred technique and expected cosmetic results. Between January 1997 and August 2000, 149 patients underwent laparoscopic appendectomy and were assigned to undergo one of the three techniques. Operative results, morbidity, and hospital stay were similar. Twenty-five percent of patients submitted to technique 1 (no suprapubic trocars) were satisfied with their method, vs 54% of patients with technique 2 (one suprapubic port, angled working trocars) and 100% of patients with technique 3 (two suprapubic parallel trocars). Almost all patients (92% of those who had technique 1 and 100% of those who had techniques 2 and 3) chose the standard laparoscopic access as the cosmetically least attractive method. All of the healthy controls we interviewed preferred technique 3. The placement of suprapubic trocars improves the surgeon's working position during laparoscopic appendectomy. A laparoscopic approach using two suprapubic trocars yields the best cosmetic results in the opinion of the majority of patients and healthy interviewees.

  3. Needlescopic sleeve gastrectomy: pushing the boundaries of the standard technique.

    PubMed

    Loureiro, Marcelo; Sultan, Abdulah; Alhaddad, Mohannad; Mostafa, Hatem; Nocca, David; Nedelcu, Marius; Buhaimed, Walled

    2017-10-01

    Laparoscopic sleeve gastrectomy (LSG) is the most common bariatric surgery performed worldwide. Improvements in LSG have been suggested to achieve better weight loss or to lessen the complications rates. We propose a change in the standard technique to privilege the use of thinner instruments, the needlescopic sleeve gastrectomy (NSG). A 40-year-old female, BMI 40, with no previous abdominal surgery was selected for a NSG. She was placed in a semi-sitting position with the surgeon standing between the legs. Pneumoperitoneum was created through open laparoscopy; 5 trocars were inserted in standard position for laparoscopic gastric surgery. We have used one 12 mm trocar in the navel for a 5 mm scope and for stapling the stomach; one 5 mm trocar for impedance coagulator and also for the scope during the stapling process, and three 3 mm trocars for liver retraction, left hand manipulation, and greater curve exposition. Surgical techniques are basically the same as for a standard LSG until the moment of stapling the stomach, when the 5 mm scope is changed to the right hand trocar. Stapling can be done trough the umbilical port, parallel to the lesser curvature, in contact with the calibration tube. After stapling, hemostasis was achieved by bipolar coagulation, application of titanium clips, and absorbable suture. The 12 mm umbilical orifice is closed after extraction of the resected stomach. Operative time was 76 min. There was no per-operative complication. Recovery was uneventful and patient was discharged at post operative day 2. Pain was considered minor by the patient. One month after surgery, cosmetic results were very convincing. There are several proposed technical modifications in LSG. They can influence complication rates or weight loss like the length of antrum resection, the size of Fouchet tube, or the reinforcement of staple line [1-4]. Besides that other concepts regarding reduction of size or number of trocars have also been applied. LSG has been

  4. Complications and adequacy of transplant kidney biopsies: A comparison of techniques.

    PubMed

    Plattner, Brett W; Chen, Pauline; Cross, Richard; Leavitt, Matthew A; Killen, Paul D; Heung, Michael

    2018-05-01

    Kidney biopsies are an essential tool in the diagnosis and management of kidney diseases, particularly in kidney transplant recipients. Biopsies carry a risk for serious complications and not all biopsies achieve adequate tissue. We examined the impact of kidney biopsy technique on complications and biopsy adequacy. The cohort consisted of consecutive kidney transplant patients undergoing biopsy by one of three techniques: ultrasound localization, real-time ultrasound guidance, and ultrasound-guided trocar placement. Variables of interest included patient characteristics and procedural characteristics. The primary outcome was serious complication attributable to kidney biopsy, and the secondary outcome was biopsy adequacy as defined by Banff criteria. Among 263 patients undergoing biopsy, 27 (10.3%) had a complication (14 with gross hematuria, 10 requiring blood transfusion, 3 requiring an unplanned interventional radiology procedure, 1 kidney loss; no deaths). Complications were more common among patients biopsied using ultrasound-guided trocar compared to real-time ultrasound and ultrasound localization (21.4% vs 7.9% vs 7.1%, respectively, p = 0.008). After adjusting for patient and procedure characteristics, technique was no longer significantly associated with complication. Biopsy adequacy was significantly higher when using ultrasound localization and real-time ultrasound compared to ultrasound-guided trocar (84.6% vs 86.8% vs 69.6%, p = 0.029), and this finding persisted in adjusted analysis. Kidney biopsy complications appear to be similar when using any of the three techniques examined in our study. However, ultrasound-guided trocar technique may yield lower biopsy adequacy when compared to non-trocar techniques.

  5. Separating the Laparoscopic Camera Cord From the Monopolar "Bovie" Cord Reduces Unintended Thermal Injury From Antenna Coupling: A Randomized Controlled Trial.

    PubMed

    Robinson, Thomas N; Jones, Edward L; Dunn, Christina L; Dunne, Bruce; Johnson, Elizabeth; Townsend, Nicole T; Paniccia, Alessandro; Stiegmann, Greg V

    2015-06-01

    The monopolar "Bovie" is used in virtually every laparoscopic operation. The active electrode and its cord emit radiofrequency energy that couples (or transfers) to nearby conductive material without direct contact. This phenomenon is increased when the active electrode cord is oriented parallel to another wire/cord. The parallel orientation of the "Bovie" and laparoscopic camera cords cause transfer of energy to the camera cord resulting in cutaneous burns at the camera trocar incision. We hypothesized that separating the active electrode/camera cords would reduce thermal injury occurring at the camera trocar incision in comparison to parallel oriented active electrode/camera cords. In this prospective, blinded, randomized controlled trial, patients undergoing standardized laparoscopic cholecystectomy were randomized to separated active electrode/camera cords or parallel oriented active electrode/camera cords. The primary outcome variable was thermal injury determined by histology from skin biopsied at the camera trocar incision. Eighty-four patients participated. Baseline demographics were similar in the groups for age, sex, preoperative diagnosis, operative time, and blood loss. Thermal injury at the camera trocar incision was lower in the separated versus parallel group (31% vs 57%; P = 0.027). Separation of the laparoscopic camera cord from the active electrode cord decreases thermal injury from antenna coupling at the camera trocar incision in comparison to the parallel orientation of these cords. Therefore, parallel orientation of these cords (an arrangement promoted by integrated operating rooms) should be abandoned. The findings of this study should influence the operating room setup for all laparoscopic cases.

  6. Bladder perforation during sling procedures: diagnosis and management of injury.

    PubMed

    Israfil-Bayli, F; Bulchandani, S; Parsons, M; Jackson, S; Toozs-Hobson, P

    2014-05-01

    Midurethral slings are an effective and minimally invasive treatment for stress urinary incontinence. One of the most common intraoperative complications is bladder perforation, complicating between 2 and 10% of all operations, and on average 4.7%. It is usually corrected during surgery, with repositioning of the trocars. The purpose of this video is to demonstrate a method of replacing the trocars under direct vision. This video exhibits a bladder perforation during insertion of a retropubic midurethral sling (Advantage Fit; Boston Scientific) and gives a step-by step guide to the removal and repositioning of the sling under direct visualisation. Repositioning of the trocars under direct vision in cases of bladder perforation may have numerous advantages. It may prevent damage to the urethra, possibly reduce the risk of postoperative infection and may be beneficial for trainees.

  7. Trocar-guided trans-vaginal mesh surgery for pelvic organ prolapse: effects on urinary continence and anatomical and functional outcomes. A prospective observational study.

    PubMed

    Natale, F; Costantini, E; La Penna, C; Illiano, E; Balsamo, R; Carbone, A; Cervigni, M

    2017-03-01

    Primary objective of this study was to assess the effects of trocar-guided transvaginal mesh surgery (TVM) on cure and prevention rates for incontinence, without concomitant surgery for Stress Urinary Incontinence (SUI). Our secondary objectives were anatomical outcomes, relief of symptoms and effect on quality of life (QoL). This prospective observational study evaluated women who underwent TVM for symptomatic stage >2 Pelvic Organ Prolapse (POP). SUI was evaluated objectively using the cough stress test with prolapse reduced. SUI and urge urinary incontinence (UUI) were subjectively evaluated using ICIQ-SF. Anatomical cure was defined as stage <2 at POP-Q. McNemar chi-square test; paired t-test; Mann-Whitney test. Seventy-two patients reached final evaluation (mean follow-up 72 months). In the 40 pre-op continent patients, 34 (85%) remained continent postoperatively and 6 (15%) showed de novo SUI. Only 1 patient chose to undergo subsequent TVT. The number needed to treat was 6 to prevent 1 women developing de novo objective SUI and 39 to prevent 1 woman having to undergo SUI surgery. In the 32 pre-op incontinent patients, 18 (56.3%) became continent postoperatively. Only 1 patient chose to undergo subsequent TVT. UUI was present in 44 patients pre-operatively and 15 (20.8%) post-operatively (1 de novo). Forty-four patients (61.1%) were continent post-operatively for SUI and UUI. We observed a significant improvement in storage, voiding, post-micturition and prolapse-related symptoms. The anatomical cure rate was 87.5% for the anterior compartment and 90.3%.for the apical segment. The apical recurrence was 8.3% in the patients previously hysterectomised, 18.8% in the patients with uterus preservation and 0% in the patients with concomitant hysterectomy. QoL scores improved in all domains except sleep and personal relationships. We observed mesh exposure in 10 patients (13.9%), in 5 of whom it was associated with a concomitant hysterectomy CONCLUSIONS: TVM showed

  8. Miyake-Apple view of inner side of sclerotomy during microincision vitrectomy surgery.

    PubMed

    Inoue, Makoto; Ota, Ichiro; Taniuchi, Shutaro; Nagamoto, Toshiyuki; Miyake, Kensaku; Hirakata, Akito

    2011-08-01

    To examine the inner surface of the sclerotomy during microincision vitrectomy surgery by Miyake-Apple view. The anterior half of porcine eyes was attached to a transparent acrylic plate with cyanoacrylate glue. Then, either a 23-gauge or a 25-gauge trocar-cannula was inserted through the sclera obliquely. The inner surface of the entrance site was observed posteriorly by Miyake-Apple view. These images were compared with the endoscopic view of two patients who underwent vitreous surgery for an epiretinal membrane. When the trocar-cannula was inserted obliquely, the Miyake-Apple view showed that the ciliary epithelium at the sclerotomy site was stretched. When the trocar-cannula was inserted vertically, the ciliary epithelium was folded, and the folds remained even after the trocar was removed. Vitreous strands were seen incarcerated into the sclerotomy site. In human eyes, a folding of the ciliary epithelium was not clearly seen with the endoscopic view but the incarcerated vitreous was seen. The Miyake-Apple view provided a precise, in vivo, observation of the inner surface of the entry site. It disclosed the morphological stress on the ciliary epithelium by the sclerotomy. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  9. Port closure techniques.

    PubMed

    Shaher, Z

    2007-08-01

    Laparoscopic trocars do create wounds. This article aims to review and list different techniques used for closure of the fascia incision at trocar sites. A literature search was performed for articles dealing with closure techniques. The author searched this subject in English on Medline by combining the words "trocar" and "hernia," as well as "Deschamps" and "Reverdin." All articles reporting techniques with their references were reviewed. The articles described many techniques in addition to classical closure using curved needles, including Grice needle, Maciol needles, Endoclose device, Carter-Thomason device, Tahoe ligature device, Endo-Judge device, eXit puncture closure device, Lowsley retractor, spinal cord needles, dual hemostat, suture carrier, Riverdin and Deschamps needles, and Gore-Tex closure device. Three main groups of techniques were found with favor of extracorporeal manipulations under direct visualization. Old methods are sufficient and cost-effective.

  10. The "Hoover" (vacuum cleaner) technique for calcifying tendonitis deposits excision and removal of the calcific debris.

    PubMed

    Ehud, Atoun; Ehud, Rath; Alexander, Van Tongel; Ali, Narvani; Giusseppe, Sforza; Ofer, Levy

    2012-07-01

    A new technical tip for the improvement of the arthroscopic treatment of symptomatic calcifying tendinitis is described. Arthroscopic excision of calcifying tendonitis may result with multiple minute calcific debris in the subacromial bursa, causing severe post operative pain due to chemical irritation of the bursa. We suggest the use of a bladeless shaver barrel as a "Hoover" (vacuum cleaner) for arthroscopic clearance of these miniature calcific debris from the subacromial space after resection of the major deposits. The use of this technique resulted in good clinical outcome with improved post operative pain.

  11. The importance of instrumentation and documentation in gynecological laparoscopy.

    PubMed

    Berci, G; Adler, D N; Brooks, P G; Pasternak, A; Hasler, G

    1973-06-01

    It is estimated that approximately 10,000 gynecological laparoscopies have been performed each year for the last 2 years and the number is increasing. This is a report on the evaluation of 14 separate endoscopic instruments. To produce pneumoperitoneum, air has been replaced by carbon dioxide gas or nitrous oxygen. The Semm insufflator measures the intra-abdominal pressure and indicates when the inflow of gas meets resistance. This aids in determining the proper position of the needle. The clinical impression is that intra-abdominal pressure in the vicinity of 25 mm Hg rather than 16 mm is most important. The Veress pneumo-needle with the spring-loaded stylet helps avoid injury to viscera. The trocar is the most dangerous tool. The smallest (7 mm) diameter with the shortest sharp tip is recommended. The first optical system (invented in 1875) has been replaced by the "rod-lens" system, which increases light transmission, gives a brighter image, has a wider viewing angle, and has a smaller outside diameter of the telescope. Use of a second trocar is safer because introduction is observed under visual control. The punch-type of biopsy forceps provides a smooth sharp cut dividing the tubes after coagulation and transects a 3 mm sample for microscopic examination. Another smaller trocar may be needed to pass through a grasping forceps to hold the ovary in position if a biopsy of the ovary is needed. The coagulation-suction probe may be used if hemorrhage obscures the operating field. Burn accidents may occur unless half to 1 inch of the insulated part of the instrument protrudes beyond the metal trocar. Solid-state electro-surgical units are recommended over the old spark-gap-generation type. Proper inspection of all electrical equipment before use is needed to prevent burns. After appropriate cleaning and drying of instruments, gas sterilization is recommended. The single puncture approach is not recommended as two trocars are more efficient. Under investigation are

  12. Defining the learning curve of laparoendoscopic single-site Heller myotomy.

    PubMed

    Ross, Sharona B; Luberice, Kenneth; Kurian, Tony J; Paul, Harold; Rosemurgy, Alexander S

    2013-08-01

    Initial outcomes suggest laparoendoscopic single-site (LESS) Heller myotomy with anterior fundoplication provides safe, efficacious, and cosmetically superior outcomes relative to conventional laparoscopy. This study was undertaken to define the learning curve of LESS Heller myotomy with anterior fundoplication. One hundred patients underwent LESS Heller myotomy with anterior fundoplication. Symptom frequency and severity were scored using a Likert scale (0 = never/not bothersome to 10 = always/very bothersome). Symptom resolution, additional trocars, and complications were compared among patient quartiles. Median data are presented. Preoperative frequency/severity scores were: dysphagia = 10/8 and regurgitation = 8/7. Additional trocars were placed in 12 patients (10%), of whom all were in the first two quartiles. Esophagotomy/gastrotomy occurred in three patients. Postoperative complications occurred in 9 per cent. No conversions to "open" operations occurred. Length of stay was 1 day. Postoperative frequency/severity scores were: dysphagia = 2/0 and regurgitation = 0/0; scores were less than before myotomy (P < 0.001). There were no apparent scars, except where additional trocars were placed. LESS Heller myotomy with anterior fundoplication well palliates symptoms of achalasia with no apparent scar. Placement of additional trocars only occurred early in the experience. For surgeons proficient with the conventional laparoscopic approach, the learning curve of LESS Heller myotomy with anterior fundoplication is short and safe, because proficiency is quickly attained.

  13. Consensus statement of the consortium for LESS cholecystectomy.

    PubMed

    Ross, Sharona; Rosemurgy, Alexander; Albrink, Michael; Choung, Edward; Dapri, Giovanni; Gallagher, Scott; Hernandez, Jonathan; Horgan, Santiago; Kelley, William; Kia, Michael; Marks, Jeffrey; Martinez, Jose; Mintz, Yoav; Oleynikov, Dmitry; Pryor, Aurora; Rattner, David; Rivas, Homero; Roberts, Kurt; Rubach, Eugene; Schwaitzberg, Steven; Swanstrom, Lee; Sweeney, John; Wilson, Erik; Zemon, Harry; Zundel, Natan

    2012-10-01

    Many surgeons attempting Laparo-Endoscopic Single Site (LESS) cholecystectomy have found the operation difficult, which is inconsistent with our experience. This article is an attempt to promote a standardized approach that we feel surgeons with laparoscopic skills can perform safely and efficiently. This is a four-trocar approach consistent with the four incisions utilized in conventional laparoscopic cholecystectomy. After administration of general anesthesia, marcaine is injected at the umbilicus and a 12-mm vertical incision is made through the already existing anatomical scar of the umbilicus. A single four-trocar port is inserted. A 5-mm deflectable-tip laparoscope is placed through the trocar at the 8 o'clock position, a bariatric length rigid grasper is inserted through the trocar at the 4 o'clock position (to grasp the fundus), and a rigid bent grasper is placed through the 10-mm port (to grasp the infundibulum). This arrangement of the instruments promotes minimal internal and external instrument clashing with simultaneous optimization of the operative view. This orientation allows retraction of the gallbladder in a cephalad and lateral direction, development of a window between the gallbladder and the liver which promotes the "critical view" of the cystic duct and artery, and provides triangulation with excellent visualization of the operative field. The operation is concluded with diaphragmatic irrigation of marcaine solution to minimize postoperative pain. Standardization of LESS cholecystectomy will speed adoption, reduce intraoperative complications, and improve the efficiency and safety of the approach.

  14. Anopheles gambiae genome reannotation through synthesis of ab initio and comparative gene prediction algorithms

    PubMed Central

    Li, Jun; Riehle, Michelle M; Zhang, Yan; Xu, Jiannong; Oduol, Frederick; Gomez, Shawn M; Eiglmeier, Karin; Ueberheide, Beatrix M; Shabanowitz, Jeffrey; Hunt, Donald F; Ribeiro, José MC; Vernick, Kenneth D

    2006-01-01

    Background Complete genome annotation is a necessary tool as Anopheles gambiae researchers probe the biology of this potent malaria vector. Results We reannotate the A. gambiae genome by synthesizing comparative and ab initio sets of predicted coding sequences (CDSs) into a single set using an exon-gene-union algorithm followed by an open-reading-frame-selection algorithm. The reannotation predicts 20,970 CDSs supported by at least two lines of evidence, and it lowers the proportion of CDSs lacking start and/or stop codons to only approximately 4%. The reannotated CDS set includes a set of 4,681 novel CDSs not represented in the Ensembl annotation but with EST support, and another set of 4,031 Ensembl-supported genes that undergo major structural and, therefore, probably functional changes in the reannotated set. The quality and accuracy of the reannotation was assessed by comparison with end sequences from 20,249 full-length cDNA clones, and evaluation of mass spectrometry peptide hit rates from an A. gambiae shotgun proteomic dataset confirms that the reannotated CDSs offer a high quality protein database for proteomics. We provide a functional proteomics annotation, ReAnoXcel, obtained by analysis of the new CDSs through the AnoXcel pipeline, which allows functional comparisons of the CDS sets within the same bioinformatic platform. CDS data are available for download. Conclusion Comprehensive A. gambiae genome reannotation is achieved through a combination of comparative and ab initio gene prediction algorithms. PMID:16569258

  15. Pneumovesicoscopic treatment of congenital bladder diverticula in children: our experience.

    PubMed

    Marte, Antonio; Sabatino, Maria D; Borrelli, Micaela; Del Balzo, Biago; Nino, Fabiano; Prezioso, Maurizio; Parmeggiani, Pio

    2010-02-01

    In this article, we report our experience with diverticulectomies of symptomatic congenital bladder diverticula in children, which was performed by utilizing pneumovesicoscopy. Six boys, 4-8 years of age (mean, 5.6) underwent pneumovesicoscopic diverticulectomy at our institution from June 2007 to June 2008. There were 4 right-single diverticula and 2 double-left diverticula. Under cystoscopic control, after the cystopexy to the abdominal wall, a midline 5-mm trocar for a 0-degree telescope and two lateral 3-mm reusable trocars through the anterolateral wall of the bladder in the midclavicular line were introduced, insufflating the bladder with carbondioxide to 10-12 mm Hg pressure. The diverticulum/a were inverted into the bladder and the mucosa around the neck was circumcized by using scissors and a monopolar hook. The defect was sutured with interrupted sutures and the bladder was drained with a Foley catheter, which was introduced at the site of the 5-mm port, and a urethral catheter. Mean operative time was 110 minutes. No major peri- or postoperative complications were recorded, except that the displacement of one of the lateral trocars that resulted in gas leakage in 1 case. The trocar was replaced and the procedure was completed. An ultrasound and a voiding cystourethrogram, performed from 3 to 6 months after the operation, showed the disappearance of the diverticulum/a. In our experience, pneumovesicoscopic diverticulectomy is an easy, safe procedure and can be considered a valid alternative to the open or laparoscopic procedures. It also provides no postoperative discomfort and a good cosmetic result.

  16. Novel hybrid (magnet plus curve grasper) technique during transumbilical cholecystectomy: initial experience of a promising approach.

    PubMed

    Millan, Carolina; Bignon, Horacion; Bellia, Gaston; Buela, Enrique; Rabinovich, Fernando; Albertal, Mariano; Martinez Ferro, Marcelo

    2013-10-01

    The use of magnets in transumbilical cholecystectomy (TUC) improves triangulation and achieves an optimal critical view. Nonetheless, the tendency of the magnets to collide hinders the process. In order to simplify the surgical technique, we developed a hybrid model with a single magnet and a curved grasper. All TUCs performed with a hybrid strategy in our pediatric population between September 2009 and July 2012 were retrospectively reviewed. Of 260 surgical procedures in which at least one magnet was used, 87 were TUCs. Of those, 62 were hybrid: 33 in adults and 29 in pediatric patients. The technique combines a magnet and a curved grasper. Through a transumbilical incision, we placed a 12-mm trocar and another flexible 5-mm trocar. The laparoscope with the working channel used the 12-mm trocar. The magnetic grasper was introduced to the abdominal cavity using the working channel to provide cephalic retraction of the gallbladder fundus. Across the flexible trocar, the assistant manipulated the curved grasper to mobilize the infundibulum. The surgeon operated through the working channel of the laparoscope. In this pediatric population, the mean age was 14 years (range, 4-17 years), and mean weight was 50 kg (range, 18-90 kg); 65% were girls. Mean operative time was 62 minutes. All procedures achieved a critical view of safety with no instrumental collision. There were no intraoperative or postoperative complications. The hospital stay was 1.4±0.6 days, and the median follow-up was 201 days. A hybrid technique, combining magnets and a curved grasper, simplifies transumbilical surgery. It seems feasible and safe for TUC and potentially reproducible.

  17. Laparoscopic technique of modified extraperitoneal (retrotransversalis) end colostomy for abdomino-perineal resection.

    PubMed

    Tulina, I A; Kitsenko, Y E; Ubushiev, M N; Efetov, S K; Wexner, S; Tsarkov, P V

    2018-05-19

    To describe the technique of a modified extraperitoneal retrotransversalis end colostomy as part of a laparoscopic abdomino-perineal resection (APR). The colostomy site is preoperatively chosen and intraoperatively used for a trocar. After the rectum has been mobilized the descending colon is freed. The peritoneal margin is gently grasped and the parietal peritoneum, extraperitoneal together with the transversalis fascia are separated from the transverse abdominal muscle fibres upwards for 3-4 cm aiming at the trocar site to form the extraperitoneal retrotransversalis canal. The stoma site trocar is partially withdrawn and its head is turned laterally until its tip is positioned in the layer between abdominal wall muscles and underlying transversalis and extraperitoneal fascia together with parietal peritoneum. The CO 2 source can be attached so that the gas helps to separate the layers. After that the colostomy trephine is formed at the site of the trocar, the grasper is inserted to gently deliver the blunt end of the descending colon through the canal and the end colostomy is formed in a usual way. No procedure specific complications were noted in 39 patients who had laparoscopic APR with extraperitoneal retrotransversalis end colostomy from 2009 to 2016. In 23 patients who survived 3.7 ± 1.7 years after surgery there were no clinical or CT signs of parastomal hernia or prolapse. This single institution retrospective case series demonstrate that laparoscopic extraperitoneal retrotransversalis end colostomy is feasible, safe, and effective in preventing parastomal hernias and stomal prolapse This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  18. Safe percutaneous suprapubic catheterisation.

    PubMed

    Goyal, N K; Goel, A; Sankhwar, S N

    2012-11-01

    We describe our technique of percutaneous suprapubic catheter insertion with special reference to steps that help to avoid common complications of haematuria and catheter misplacement. The procedure is performed using a stainless steel reusable trocar under local infiltrative anaesthesia, usually at the bedside. After clinical confirmation of a full bladder, the trocar is advanced into the bladder through a skin incision. Once the bladder is entered, the obturator is removed and the assistant inserts a Foley catheter followed by rapid balloon inflation. Slight traction is applied to the catheter for about five minutes. Patients with previous lower abdominal surgery, an inadequately distended bladder or acute pelvic trauma do not undergo suprapubic catheterisation using this method. The procedure was performed in 72 men (mean age: 42.4 years, range: 18-78 years) with urinary retention with a palpable bladder. The average duration of the procedure was less than five minutes. No complications were noted in any of the patients. Trocar suprapubic catheter insertion is a safe and effective bedside procedure for emergency bladder drainage and can be performed by resident surgeons. The common complications associated with the procedure can be avoided with a few careful steps.

  19. Surgical robot setup simulation with consistent kinematics and haptics for abdominal surgery.

    PubMed

    Hayashibe, Mitsuhiro; Suzuki, Naoki; Hattori, Asaki; Suzuki, Shigeyuki; Konishi, Kozo; Kakeji, Yoshihiro; Hashizume, Makoto

    2005-01-01

    Preoperative simulation and planning of surgical robot setup should accompany advanced robotic surgery if their advantages are to be further pursued. Feedback from the planning system will plays an essential role in computer-aided robotic surgery in addition to preoperative detailed geometric information from patient CT/MRI images. Surgical robot setup simulation systems for appropriate trocar site placement have been developed especially for abdominal surgery. The motion of the surgical robot can be simulated and rehearsed with kinematic constraints at the trocar site, and the inverse-kinematics of the robot. Results from simulation using clinical patient data verify the effectiveness of the proposed system.

  20. The learning curve of laparoendoscopic single-Site (LESS) fundoplication: definable, short, and safe.

    PubMed

    Ross, Sharona B; Choung, Edward; Teta, Anthony F; Colibao, Lotiffa; Luberice, Kenneth; Paul, Harold; Rosemurgy, Alexander S

    2013-01-01

    This study of laparoendoscopic single-site (LESS) fundoplication for gastroesophageal reflux disease was undertaken to determine the "learning curve" for implementing LESS fundoplication. One hundred patients, 38% men, with a median age of 61 years and median body mass index of 26 kg/m(2) , underwent LESS fundoplications. The operative times, placement of additional trocars, conversions to "open" operations, and complications were compared among patient quartiles to establish a learning curve. Median data are reported. The median operative times and complications did not differ among 25-patient cohorts. Additional trocars were placed in 27% of patients, 67% of whom were in the first 25-patient cohort. Patients undergoing LESS fundoplication had a dramatic relief in the frequency and severity of all symptoms of reflux across all cohorts equally (P < .05), particularly for heartburn and regurgitation, without causing dysphagia. LESS fundoplication ameliorates symptoms of gastroesophageal reflux disease without apparent scarring. Notably, few operations required additional trocars after the first 25-patient cohort. Patient selection became more inclusive (eg, more "redo" fundoplications) with increasing experience, whereas operative times and complications remained relatively unchanged. The learning curve of LESS fundoplication is definable, short, and safe. We believe that patients will seek LESS fundoplication because of the efficacy and superior cosmetic outcomes; surgeons will need to meet this demand.

  1. Survival of shovelnose sturgeon after abdominally invasive endoscopic evaluation

    USGS Publications Warehouse

    Trested, D.G.; Goforth, Reuben R.; Kirk, J.P.; Isely, J.J.

    2010-01-01

    The development of effective and minimally invasive techniques to determine gender and gonad developmental stage is particularly important in performing accurate fisheries assessments for use in conservation and restoration. The initial and latent survival of shovelnose sturgeon Scaphirhynchus platorynchus was assessed after exposure to a modified endoscopic technique designed to collect that biological information. Rather than inserting the endoscope through the urogenital canal or directly into the body cavity, we inserted a threaded trocar through a ventral incision and used a low-pressure air supply attached to the trocar to gently insufflate the body cavity. The initial survival of both experimental and control shovelnose sturgeon was 100%. Latent survival was 100% and 90% for the experimental and control fish, respectively. Our study suggests that incision endoscopy coupled with insufflation of the body cavity through the use of a trocar and an air supply is a safe and effective way to determine gender and examine the gonad developmental stage of shovelnose sturgeon. The short duration of the procedure and the high postprocedure survival suggest that this technique is suitable for shovelnose sturgeon and perhaps for the evaluation of other endangered fish species (e.g., pallid sturgeon S. alba) as well.

  2. Full Robotic Colorectal Resections for Cancer Combined With Other Major Surgical Procedures: Early Experience With the da Vinci Xi.

    PubMed

    Morelli, Luca; Di Franco, Gregorio; Guadagni, Simone; Palmeri, Matteo; Gianardi, Desirée; Bianchini, Matteo; Moglia, Andrea; Ferrari, Vincenzo; Caprili, Giovanni; D'Isidoro, Cristiano; Melfi, Franca; Di Candio, Giulio; Mosca, Franco

    2017-08-01

    The da Vinci Xi has been developed to overcome some of the limitations of the previous platform, thereby increasing the acceptance of its use in robotic multiorgan surgery. Between January 2015 and October 2015, 10 patients with synchronous tumors of the colorectum and others abdominal organs underwent robotic combined resections with the da Vinci Xi. Trocar positions respected the Universal Port Placement Guidelines provided by Intuitive Surgical for "left lower quadrant," with trocars centered on the umbilical area, or shifted 2 to 3 cm to the right or to the left, depending on the type of combined surgical procedure. All procedures were completed with the full robotic technique. Simultaneous procedures in same quadrant or left quadrant and pelvis, or left/right and upper, were performed with a single docking/single targeting approach; in cases of left/right quadrant or right quadrant/pelvis, we performed a dual-targeting operation. No external collisions or problems related to trocar positions were noted. No patient experienced postoperative surgical complications and the mean hospital stay was 6 days. The high success rate of full robotic colorectal resection combined with other surgical interventions for synchronous tumors, suggest the efficacy of the da Vinci Xi in this setting.

  3. Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment

    PubMed Central

    López-Mir, F.; Naranjo, V.; Fuertes, J. J.; Alcañiz, M.; Bueno, J.; Pareja, E.

    2013-01-01

    Purpose. This work presents the protocol carried out in the development and validation of an augmented reality system which was installed in an operating theatre to help surgeons with trocar placement during laparoscopic surgery. The purpose of this validation is to demonstrate the improvements that this system can provide to the field of medicine, particularly surgery. Method. Two experiments that were noninvasive for both the patient and the surgeon were designed. In one of these experiments the augmented reality system was used, the other one was the control experiment, and the system was not used. The type of operation selected for all cases was a cholecystectomy due to the low degree of complexity and complications before, during, and after the surgery. The technique used in the placement of trocars was the French technique, but the results can be extrapolated to any other technique and operation. Results and Conclusion. Four clinicians and ninety-six measurements obtained of twenty-four patients (randomly assigned in each experiment) were involved in these experiments. The final results show an improvement in accuracy and variability of 33% and 63%, respectively, in comparison to traditional methods, demonstrating that the use of an augmented reality system offers advantages for trocar placement in laparoscopic surgery. PMID:24236293

  4. New methods of magnet-based instrumentation for NOTES.

    PubMed

    Magdeburg, Richard; Hauth, Daniel; Kaehler, Georg

    2013-12-01

    Laparoscopic surgery has displaced open surgery as the standard of care for many clinical conditions. NOTES has been described as the next surgical frontier with the objective of incision-free abdominal surgery. The principal challenge of NOTES procedures is the loss of triangulation and instrument rigidity, which is one of the fundamental concepts of laparoscopic surgery. To overcome these problems necessitates the development of new instrumentation. material and methods: We aimed to assess the use of a very simple combination of internal and external magnets that might allow the vigorous multiaxial traction/counter-traction required in NOTES procedures. The magnet retraction system consisted of an external magnetic assembly and either small internal magnets attached by endoscopic clips to the designated tissue (magnet-clip-approach) or an endoscopic grasping forceps in a magnetic deflector roll (magnet-trocar-approach). We compared both methods regarding precision, time and efficacy by performing transgastric partial uterus resections with better results for the magnet-trocar-approach. This proof-of-principle animal study showed that the combination of external and internal magnets generates sufficient coupling forces at clinically relevant abdominal wall thicknesses, making them suitable for use and evaluation in NOTES procedures, and provides the vigorous multiaxial traction/counter-traction required by the lack of additional abdominal trocars.

  5. Safe percutaneous suprapubic catheterisation

    PubMed Central

    Goyal, NK; Goel, A; Sankhwar, SN

    2012-01-01

    INTRODUCTION We describe our technique of percutaneous suprapubic catheter insertion with special reference to steps that help to avoid common complications of haematuria and catheter misplacement. METHODS The procedure is performed using a stainless steel reusable trocar under local infiltrative anaesthesia, usually at the bedside. After clinical confirmation of a full bladder, the trocar is advanced into the bladder through a skin incision. Once the bladder is entered, the obturator is removed and the assistant inserts a Foley catheter followed by rapid balloon inflation. Slight traction is applied to the catheter for about five minutes. Patients with previous lower abdominal surgery, an inadequately distended bladder or acute pelvic trauma do not undergo suprapubic catheterisation using this method. RESULTS The procedure was performed in 72 men (mean age: 42.4 years, range: 18–78 years) with urinary retention with a palpable bladder. The average duration of the procedure was less than five minutes. No complications were noted in any of the patients. CONCLUSIONS Trocar suprapubic catheter insertion is a safe and effective bedside procedure for emergency bladder drainage and can be performed by resident surgeons. The common complications associated with the procedure can be avoided with a few careful steps. PMID:23131233

  6. Microbiological evaluation of the steam sterilization of assembled laparoscopic instruments 1

    PubMed Central

    de Camargo, Tamara Carolina; Graziano, Kazuko Uchikawa; Almeida, Alda Graciele Claudio dos Santos; Suzuki, Karina; da Silva, Cely Barreto; Pinto, Flávia Morais Gomes

    2016-01-01

    ABSTRACT Objective: assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination. Method: a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator. Three of them were introduced into each instrument at the time of assembly, and sterilized at pressurized saturated steam, 134oC for 5 minutes. After sterilization, the instrument was disassembled and each filter paper substrate was inoculated in soybean casein culture and incubated at 56oC for 21 days. In case of absence of growth, they were subjected to heat shock of 80oC, for 20 minutes and re-incubated for 72 hours. Sample size: 185 graspers and 185 trocars, with 95% power. We paired the experiments with comparative negative control groups (5 graspers and 5 trocars with challenge contamination, sterilized disassembled) and positive control (30 filter paper supports, unsterilized), subject to the same incubation procedures. Results: there was no microbial growth in experimental and negative control. The results of the positive control were satisfactory. Conclusion: this study provided strong scientific evidence to support the safety of steam sterilizing of the assembled laparoscopic instrument. PMID:27878222

  7. 21 CFR 884.1640 - Culdoscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the female genital organs. This generic type of device may include trocar and cannula, instruments... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula...

  8. 21 CFR 884.1640 - Culdoscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the female genital organs. This generic type of device may include trocar and cannula, instruments... instruments include: lens cleaning brush, biopsy brush, clip applier (without clips), applicator, cannula...

  9. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... genital organs. This generic type of device may include: Trocar and cannula, instruments used through an... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...

  10. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... genital organs. This generic type of device may include: Trocar and cannula, instruments used through an... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...

  11. A newly developed oval-shaped port device (E•Z ACCESS Oval type) for use in reduced port surgery: initial clinical experiences with cholecystectomy.

    PubMed

    Shibao, Kazunori; Takagi, Tsuyoshi; Higure, Aiichiro; Yamaguchi, Koji

    2013-09-01

    We recently developed an oval-shaped E•Z Access device designed exclusively for use with the LAP PROTECTOR™ Oval type device (Hakko Co. Ltd., Tokyo, Japan). The transverse abdominal opening diameter made by round-shaped (Alexis® Wound Retractor, Applied Medical, Rancho Santa Margarita, CA; and LAP PROTECTOR™ Round type) and oval-shaped (LAP PROTECTOR™ Oval type) wound retractors was measured and compared in 5 patients with cholecystolithiasis. Each device was placed through a single 25-mm longitudinal umbilical incision, and the length of trocar separation was compared. LESS cholecystectomy was then performed using the oval-shaped E•Z ACCESS/LAP PROTECTOR™. The transverse abdominal opening diameter was maximized with the LAP PROTECTOR™ Oval type device. The average distance between the working-ports for the glove method, round-shaped, and oval-shaped E•Z ACCESS/LAP PROTECTOR™ devices in the 25-mm umbilical incisions were 20 ± 0.8 mm, 24 ± 1.5 mm, and 35 ± 0.8 mm, respectively. Wider trocar separation was achieved using the oval-shaped device, making the surgical procedures easier to perform. No perioperative port-related or surgical complications were observed. LESS cholecystectomy using the E•Z ACCESS Oval type device was found to be technically feasible. The Oval type device appears to allow for wider trocar separation, thereby reducing stress on the surgeon, ensuring patient safety, and providing cosmetic benefits.

  12. Laparoscopic entry: a review of Canadian general surgical practice

    PubMed Central

    Compeau, Christopher; McLeod, Natalie T.; Ternamian, Artin

    2011-01-01

    Background Laparoscopic surgery has gained popularity over open conventional surgery as it offers benefits to both patients and health care practitioners. Although the overall risk of complications during laparoscopic surgery is recognized to be lower than during laparotomy, inadvertent serious complications still occur. Creation of the pneumoperitoneum and placement of laparoscopic ports remain a critical first step during endoscopic surgery. It is estimated that up to 50% of laparoscopic complications are entry-related, and most injury-related litigations are trocar-related. We sought to evaluate the current practice of laparoscopic entry among Canadian general surgeons. Methods We conducted a national survey to identify general surgeon preferences for laparoscopic entry. Specifically, we sought to survey surgeons using the membership database from the Canadian Association of General Surgeons (CAGS) with regards to entry methods, access instruments, port insertion sites and patient safety profiles. Laparoscopic cholecystectomy was used as a representative general surgical procedure. Results The survey was completed by 248 of 1000 (24.8%) registered members of CAGS. Respondents included both community and academic surgeons, with and without formal laparoscopic fellowship training. The demographic profile of respondents was consistent nationally. A substantial proportion of general surgeons (> 80%) prefer the open primary entry technique, use the Hasson trocar and cannula and favour the periumbilical port site, irrespective of patient weight or history of peritoneal adhesions. One-third of surgeons surveyed use Veress needle insufflation in their surgical practices. More than 50% of respondents witnessed complications related to primary laparoscopic trocar insertion. Conclusion General surgeons in Canada use the open primary entry technique, with the Hasson trocar and cannula applied periumbilically to establish a pneumoperitoneum for laparoscopic surgery. This

  13. Access-related complications - an analysis of 6023 consecutive laparoscopic hernia repairs.

    PubMed

    2001-01-01

    In order to investigate incidence rates and types of access-related complications that may occur during laparoscopic hernioplasty, we carried out a systematic analysis of our collected results. The aim was to identify risk factors and to develop useful modifications of the surgical technique and the instrumentation used. Since we first introduced laparoscopic hernioplasty in our clinic, we have carried out standardised, prospective documentation of relevant data from all consecutive operations in an electronic database. We performed a systematic analysis of access-related complications and their possible influencing factors, taking into special account the type of instruments used, port-site and prior intra-abdominal operations. Between April 1993 and March 2000, 4857 consecutive patients received a total of 6023 laparoscopic hernia repairs. In 510 patients three-edged, sharp trocars were used and in 4347 patients conical obturators were used to insert the port. The incidence of access-related complications was 0.9% (44/4857) in the total collection (incision hernias 0.5%, bleeding from abdominal-wall vessels 0.2%, bowel injury 0.06%, wound infections 0.06%). Injuries to intra-abdominal or retroperitoneal vessels were not observed. A differentiated analysis of the various trocar types, taking into consideration the number of inserted ports, showed that for incisions outside the linea alba the incidence of bleeding from abdominal-wall vessels was 12 times higher (0.7%, 7/1020 versus 0.06%, 5/8694). The incidence of incision hernias increased significantly (1.2%, 12/1020 versus 0.02%, 2/8694; p = 0.03) when three-edged trocars were used, as opposed to conical obturators. Our results demonstrate that, outside the linea alba, three-edged trocars should no longer be used for portinsertion. The results of our differentiated analysis of laparoscopic hernia repairs, taking into account the type of obturator, the port-site and number of ports inserted, also can be applied

  14. Creation of electron-positron plasma with superstrong laser field

    NASA Astrophysics Data System (ADS)

    Narozhny, N. B.; Fedotov, A. M.

    2014-05-01

    We present a short review of recent progress in studying QED effects within the interaction of ultra-relativistic laser pulses with vacuum and e - e + plasma. Current development in laser technologies promises very rapid growth of laser intensities in the near future. Two exawatt class facilities (ELI and XCELS, Russia) in Europe are already in the planning stage. Realization of these projects will make available a laser intensity of ˜ 1026 W/cm2 or even higher. Therefore, discussion of nonlinear optical effects in vacuum are becoming compelling for experimentalists and are currently gaining much attention. We show that, in spite of the fact that the expected field strength is still essentially less than E S = m 2 c 3/ eℏ = 1.32 · 1016 V/cm, the nonlinear vacuum effects will be accessible for observation at the ELI and XCELS facilities. The most promissory effect for observation is pair creation by a laser pulse in vacuum. It is shown, that at intensities ˜ 5 · 1025 W/cm2, creation even of a single pair is accompanied by the development of an avalanche QED cascade. There exists a distinctive feature of the laser-induced cascades, as compared with the air showers arising due primarily to cosmic rays entering the atmosphere. In our case the laser field plays not only the role of a target (similar to a nucleus in the case of air showers) but is also responsible for the acceleration of slow particles. It is shown that the effect of pair creation imposes a natural limit for the attainable laser intensity and, apparently, the field strength E ˜ E S is not accessible for a pair-creating electromagnetic field at all.

  15. Transvaginal laparoscopically assisted endoscopic cholecystectomy: preliminary clinical results for a series of 43 cases in China.

    PubMed

    Niu, Jun; Song, Wei; Yan, Ming; Fan, Wei; Niu, Weibo; Liu, Enyu; Peng, Cheng; Lin, Pengfei; Li, Peng; Khan, Abdul Qadir

    2011-04-01

    Transvaginal cholecystectomy has been performed successfully at several research institutions worldwide using natural orifice transluminal endoscopic surgery (NOTES) techniques. However, it is a growing new surgical concept in China. Several technical challenges hinder the safe clinical application of NOTES. This study investigated transvaginal endoscopic cholecystectomy performed with the assistance of a single umbilical trocar and achieved helpful initial clinical experience. From May 2009 to April 2010, a total of 43 transvaginal human cholecystectomies were performed. A single umbilical trocar was used for safe access and laparoscopic assistance during the operation. After the gallbladder had been removed through the vagina, the colpotomy was closed with absorbable stitches under direct vision. In addition, Student's t-test was performed for two samples to estimate the superiority of NOTES over a conventional laparoscopic cholecystectomy (LC) operation. The procedure was successfully completed for all the patients. No intra- or post-operative complications occurred. The patients recovered promptly after surgery, and all were satisfied with ideal cosmetic outcomes. The postoperative pain, hospital stay, and cost of hospitalization with NOTES were much less than with conventional LC operations. Although endoscopic instruments specifically designed for NOTES are not available, the addition of an umbilical trocar is an optimal way to allow safe performance of NOTES procedures in an easily reproducible manner. The authors' initial experience demonstrates that this hybrid technique is potentially feasible and effective for reducing postoperative pain and recovery times while improving the cosmetic results of transvaginal cholecystectomy.

  16. Hybrid natural orifice transluminal endoscopic cholecystectomy: prospective human series.

    PubMed

    Cuadrado-Garcia, Angel; Noguera, Jose F; Olea-Martinez, Jose M; Morales, Rafael; Dolz, Carlos; Lozano, Luis; Vicens, Jose-Carlos; Pujol, Juan José

    2011-01-01

    Natural orifice transluminal endoscopic surgery (NOTES) makes it possible to perform intraperitoneal surgical procedures with a minimal number of access points in the abdominal wall. Currently, it is not possible to perform these interventions without the help of abdominal wall entryways, so these procedures are hybrids fusing minilaparoscopy and transluminal endoscopic surgery. This report presents a prospective clinical series of 25 patients who underwent transvaginal hybrid cholecystectomy for cholelithiasis. The study comprised a clinical series of 25 consecutive nonrandomized women who underwent a fusion transvaginal NOTES and minilaparoscopy procedure with two trocars for cholelithiasis: one 5-mm umbilical trocar and one 3-mm trocar in the upper left quadrant. The study had no control group. The scheduled surgical intervention was performed for all 25 women. No intraoperative complications occurred. One patient had mild hematuria that resolved in less than 12 h, but no other complications occurred during an average follow-up period of 140 days. Of the 25 women, 20 were discharged in 24 h, and 5 were discharged less than 12 h after the procedure. Hybrid transvaginal cholecystectomy, combining NOTES and minilaparoscopy, is a good surgical model for minimally invasive surgery. It can be performed in surgical settings where laparoscopy is practiced regularly using the instruments normally used for endoscopy and laparoscopic surgery. Due to the reproducibility of the intervention and the ease of vaginal closure, hybrid transvaginal cholecystectomy will permit further development of NOTES in the future.

  17. Effects of laparotomy vs pneumoperitoneum on the hepatic catabolic stress response in ambulatory and stationary settings in pigs.

    PubMed

    Lausten, S B; Grøfte, T; Andreasen, F; Vilstrup, H; Jensen, S L

    1999-04-01

    We recently demonstrated that laparoscopic cholecystectomy is followed by a much smaller hepatic catabolic stress response than conventional cholecystectomy. It is not known what is responsible for this difference. Thirty pigs were randomly allocated to the following five treatment groups: (1) laparotomy, (2) pneumoperitoneum, (3) pneumoperitoneum with insertion of four trocars, (4) laparotomy, (5) pneumoperitoneum. Groups 1-3 were operated on in an ambulatory setting, whereas groups 4 and 5 were operated on in a stationary setting. Urea synthesis, as quantified by functional hepatic nitrogen clearance, and the response of stress hormones and cytokines were assessed. Laparotomy increased the functional hepatic nitrogen clearance by 195% (p < 0.001); pneumoperitoneum and trocars increased it by 145% (p < 0.001); and pneumoperitoneum alone increased it by 113% (p < 0. 001). The difference between laparotomy and both pneumoperitoneum groups was significant. If the stress factor of ambulatory surgery was eliminated, the increase in functional hepatic nitrogen clearance was reduced to 87% (p < 0.01) after laparotomy and 38% (NS) for animals subject to pneumoperitoneum. There were significant differences in concentrations of stress hormones, tumor necrosis factor alpha, and interleukin 8 among groups intra- and postoperatively. The magnitude of the postoperative hepatic stress response after laparotomy compared to pneumoperitoneum with and without insertion of trocars seems to be caused by the greater trauma to the abdominal wall. Furthermore, an ambulatory setting seems to be an important postoperative stress factor in itself.

  18. 21 CFR 876.5090 - Suprapubic urological catheter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... accessories is a flexible tubular device that is inserted through the abdominal wall into the urinary bladder with the aid of a trocar and cannula. The device is used to pass fluids to and from the urinary tract...

  19. 21 CFR 874.4420 - Ear, nose, and throat manual surgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device includes the esophageal dilator; tracheal bistour (a long, narrow surgical knife); tracheal dilator; tracheal hook; laryngeal injection set; laryngeal knife; laryngeal saw; laryngeal trocar...; wire ear loop; microrule; mirror; mobilizer; ear, nose, and throat punch; ear, nose and throat knife...

  20. Laparoscopic access overview: Is there a safest entry method?

    PubMed

    Bianchi, G; Martorana, E; Ghaith, A; Pirola, G M; Rani, M; Bove, P; Porpiglia, F; Manferrari, F; Micali, S

    2016-01-01

    Laparoscopy is a minimally invasive technique to access the abdominal cavity, for diagnostic or therapeutic applications. Optimizing the access technique is an important step for laparoscopic procedures. The aim of this study is to assess the outcomes of different laparoscopic access techniques and to identify the safest one. Laparoscopic access questionnaire was forwarded via e-mail to the 60 centers who are partners in working group for laparoscopic and robotic surgery of the Italian Urological Society (SIU) and their American and European reference centers. The response rate was 68.33%. The total number of procedures considered was 65.636. 61.5% of surgeons use Veress needle to create pneumoperitoneum. Blind trocar technique is the most commonly used, but has the greatest number of complications. Optical trocar technique seems to be the safest, but it's the less commonly used. The 28,2% of surgeons adopt open Hasson's technique. Total intra-operative complications rate was 3.3%. Open conversion rate was 0.33%, transfusion rate was 1.13%, and total post-operative complication rate was 2.53%. Laparoscopic access is a safe technique with low complication rate. Most of complications can be managed conservatively or laparoscopically. The choice of access technique can affect the rate and type of complications and should be planned according to surgeon experience, safety of each technique and patient characteristics. All access types have perioperative complications. According with our study, optical trocar technique seems to be the safest. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Use of a multi-instrument access device in abdominoperineal resections

    PubMed Central

    van der Linden, Yoen TK; Boersma, Doeke; Bosscha, Koop; Lips, Daniel J; Prins, Hubert A

    2016-01-01

    BACKGROUND: Laparoscopic colorectal surgery results in less post-operative pain, faster recovery, shorter length of stay and reduced morbidity compared with open procedures. Less or minimally invasive techniques have been developed to further minimise surgical trauma and to decrease the size and number of incisions. This study describes the safety and feasibility of using an umbilical multi-instrument access (MIA) port (Olympus TriPort+) device with the placement of just one 12-mm suprapubic trocar in laparoscopic (double-port) abdominoperineal resections (APRs) in rectal cancer patients. PATIENTS AND METHODS: The study included 20 patients undergoing double-port APRs for rectal cancer between June 2011 and August 2013. Preoperative data were gathered in a prospective database, and post-operative data were collected retrospectively. RESULTS: The 20 patients (30% female) had a median age of 67 years (range 46-80 years), and their median body mass index (BMI) was 26 kg/m2 (range 20-31 kg/m2). An additional third trocar was placed in 2 patients. No laparoscopic procedures were converted to an open procedure. Median operating time was 195 min (range 115-306 min). A radical resection (R0 resection) was achieved in all patients, with a median of 14 lymph nodes harvested. Median length of stay was 8 days (range 5-43 days). CONCLUSION: Laparoscopic APR using a MIA trocar is a feasible and safe procedure. A MIA port might be of benefit as an extra option in the toolbox of the laparoscopic surgeon to further minimise surgical trauma. PMID:27279397

  2. Effects of a modified technique for TVT-O positioning on postoperative pain: single-blind randomized study.

    PubMed

    Tommaselli, Giovanni A; Formisano, Carmen; Di Carlo, Costantino; Fabozzi, Annamaria; Nappi, Carmine

    2012-09-01

    One of the most frequent and distressing complications of the tension-free vaginal tape obturator (TVT-O) procedure for stress urinary incontinence (SUI) is groin pain, which may be related to the surgical technique or to the tape. The aim of this study was to evaluate the impact of a more limited dissection and a more medial trocar trajectory in TVT-O positioning on postoperative pain. Seventy-two SUI patients were randomized to undergo TVT-O either with the traditional technique (group A) or a modified procedure (reduced paraurethral dissection and a more medial trocar trajectory) (group B). Visual analog scale pain scores 12 h, 24 h, and 1 month after the procedure, number of analgesic vials, objective cure rate, and patient functional and quality of life scores 6 months after the procedure were evaluated. Data were analyzed by the Student's t test for parametric variables, the Mann-Whitney U and Wilcoxon tests for nonparametric variables, and Fisher's exact test for categorical variables. Pain scores were significantly lower in group B compared with group A 24 h after surgery (P = 0.01). Pain scores significantly decreased from 12-24 h postoperatively to 1 month follow-up in both groups (P < 0.001). No significant differences were observed in the number of analgesic vials administered, cure rates, and questionnaire scores between the two groups. More limited dissection and a more medial trocar trajectory of TVT-O seem to reduce postoperative groin pain at 24 h after the procedure, but not the analgesic requirement.

  3. Concomitant treatment of ureteropelvic junction obstruction and renal calculi with robotic laparoscopic surgery and rigid nephroscopy.

    PubMed

    Zheng, Ji; Yan, Junan; Zhou, Zhansong; Chen, Zhiwen; Li, Xin; Pan, Jinhong; Li, Weibing

    2014-01-01

    The treatment of ureteropelvic junction obstruction (UPJO) and concomitant calculus poses a technically challenging situation. We present our experience with using rigid nephroscopy for renal calculi removal during robot-assisted pyeloplasy (RAP) for UPJO. From December 2010 to November 2012, 25 patients with UPJO had RAP at our institution; 9 of those had concurrent renal calculi, which were simultaneously treated with rigid nephroscopy. For stone extraction, a rigid ureteroscope was passed through an assistant trocar under laparoscopic vision directly into a previously created pyelotomy. The stones were extracted using a rigid grasper or stone basket through the rigid ureteroscope. For the removal of the stones within the upper and lower calyces, the rigid ureteroscope was introduced into the incised renal pelvis through robotic trocars if the "assistant trocar" route failed. Complete stone clearance was achieved in 8 of 9 patients. Residual calculi in 1 patient were removed with a single session of extracorporeal shock wave lithotripsy. At the mean follow-up of 10.2 months, no patients had obstruction or recurrent stones. The mean operative time was 187.1 minutes, which was 40.9 minutes longer than the mean operative time in patients without renal calculi. There was no significant difference in blood loss, hospital stay, complications, and success rates between patients with and without renal calculi. Our data suggest that the use of a concomitant rigid nephroscope and RAP is a safe and feasible option for the treatment of UPJO complicated with renal calculi. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. The optical "Veress-needle"--initial puncture with a minioptic.

    PubMed

    Schaller, G; Kuenkel, M; Manegold, B C

    1995-02-01

    Laparoscopic access is a necessary part of minimally invasive surgery. The double blind puncture with Veress-needle and trocar can cause lethal complications such as bowel injury, bleeding and gas-embolisation. Some authors have reported alternative techniques for laparoscopic abdominal access. Because no blind procedure can absolutely prevent injury, permanent visual control of perforated tissue layers as in open surgery should be achieved to prevent possible injury at an early stage. Previously described procedures could not fulfil all requirements to comply with this ideal, i.e. permanent visual control of abdominal wall penetration prior to establishment of pneumoperitoneum and trocar insertion without further possible damage. We designed a 2 mm fibreglass optic 250 mm in length that is inserted into a suitable cannula. Special construction allows rinsing through the cannula to clear the vision and to open spaces in the puncture track by water dissection. After incision of the skin, all layers of the abdominal wall can be visualised, including blood vessels and internal surfaces. Once the abdominal cavity is reached, the needle tip is retracted and a two-step dilation allows the trocar to be introduced via the puncture track. Only then does insufflation begin. The fibreglass optic-equipped safety needle was used for visually controlled access in 184 laparoscopic surgical procedures. After a period of training, all layers of the abdominal wall could be recognised exactly. In two patients with dense adhesions, perforation of the small bowel was diagnosed immediately by endoscopic viewing. The small injury needed no treatment, and the intended procedure was completed laparoscopically.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Necrotising fasciitis after hysterectomy and concomitant transvaginal mesh repair in a patient with pelvic organ prolapse.

    PubMed

    Pushkar, Dmitry Y; Vasilchenko, Mikhail I; Kasyan, George R

    2013-10-01

    Necrotising fasciitis is a severe form of soft tissue infection. Herein, we present an unreported complication of the transvaginal repair of a pelvic organ prolapse (POP) with trocar-guided polypropylene mesh and a concomitant hysterectomy. A 61-year-old Caucasian female who had been using an intrauterine device (IUD) for 30 years presented with a stage 3 pelvic organ prolapse. A genital ultrasound examination confirmed the presence of an IUD, but found no endometrial abnormalities. The surgical management was limited to a transvaginal hysterectomy and simultaneous anterior vaginal wall repair augmented with trocar-guided mesh. A morphological examination of the removed uterus confirmed the presence of the intrauterine device and additionally found endometrial cancer (T1N0M0), which was not revealed during the preoperative ultrasound. Within 6 days of the surgery, she developed anaerobic bilateral necrotising fasciitis on both thighs. Non-clostridial streptococci were identified in the wound. After 18 days of intensive care, the patient died of fatal coagulopathy.

  6. Evaluation of a Shape Memory Alloy Reinforced Annuloplasty Band for Minimally Invasive Mitral Valve Repair

    PubMed Central

    Purser, Molly F.; Richards, Andrew L.; Cook, Richard C.; Osborne, Jason A.; Cormier, Denis R.; Buckner, Gregory D.

    2013-01-01

    Purpose An in vitro study using explanted porcine hearts was conducted to evaluate a novel annuloplasty band, reinforced with a two-phase, shape memory alloy, designed specifically for minimally invasive mitral valve repair. Description In its rigid (austenitic) phase, this band provides the same mechanical properties as the commercial semi-rigid bands. In its compliant (martensitic) phase, this band is flexible enough to be introduced through an 8-mm trocar and is easily manipulated within the heart. Evaluation In its rigid phase, the prototype band displayed similar mechanical properties to commercially available semi-rigid rings. Dynamic flow testing demonstrated no statistical differences in the reduction of mitral valve regurgitation. In its flexible phase, the band was easily deployed through an 8-mm trocar, robotically manipulated and sutured into place. Conclusions Experimental results suggest that the shape memory alloy reinforced band could be a viable alternative to flexible and semi-rigid bands in minimally invasive mitral valve repair. PMID:19766827

  7. Needle lost in minimally invasive surgery: management proposal and literature review.

    PubMed

    Medina, Luis G; Martin, Oscar; Cacciamani, Giovannni E; Ahmadi, Nariman; Castro, Juan C; Sotelo, Rene

    2018-03-19

    The reported incidence of intraoperative retained instruments, such as needles, hangs around 0.06-0.11%. Leaving a needle inside the abdominal cavity can have significant medical and legal consequences. In addition, the retrieval can be hampered due to the limited visualization of the scope during minimally invasive surgery. Factors associated with an increased probability for NL have been described. Prevention for this situation includes: having one needle at a time inside the cavity, effective communication between all personnel in the operating room, evaluation of the strength of the suture-needle connection, avoid parking of needles intraoperatively, and a proper needle withdrawal. Notwithstanding, no agreement has been made regarding NL management. Herein, we present a literature review, and a management proposal in which through a series of systematic steps, the surgical team can efficiently locate and retrieve a lost needle such as: examination of the surgical field, trocar visualization, trocar disassembly, and revision of the suction device. Finally, intraoperative or postoperative imaging can be utilized.

  8. A simple method for the comparison of commercially available ATP hygiene-monitoring systems.

    PubMed

    Colquhoun, K O; Timms, S; Fricker, C R

    1998-04-01

    The purpose of this study was to evaluate a methodology which could easily be used in any test laboratory in a uniform and consistent way for determining the sensitivity and reproducibility of results obtained with three ATP hygiene-monitoring systems. The test protocol discussed here allows such comparison to be made, thereby establishing a method of benchmarking both new systems and developments of existing systems. The sensitivity of the LUMINOMETER K, PocketSwab (Charm Sciences) was found to be between 0.4 and 4.0 nmol of ATP with poor reproducibility at the 40.0 nmol level (CV, 35%). The sensitivity of the IDEXX LIGHTING system and the Biotrace UNILITE Xcel were both between 0.04 and 0.4 nmol with coefficients of variation (CVs) of between 9% at 0.04 nmol and 10% at 0.4 nmol for the IDEXX system and 17% at 0.04 nmol and 21% at 0.4 nmol for the Biotrace system. The three systems were tested with a range of dilutions of different food residues: orange juice, raw milk, and ground beef slurry. All three test systems allowed detection of orange juice and raw milk at dilutions of 1:1,000, although the CV of results from the Charm system (54 and 74% respectively) was poor at this dilution for both residues. The sensitivity of the test systems was poorer for ground beef slurry than it was for orange juice and raw milk. Both the Biotrace and IDEXX systems were able to detect a 1:100 dilution of beef slurry (with CVs of 17 and 10% respectively), whilst at this dilution results from the Charm system had a CV of 55%. It was possible by using the method described in this paper to rank in order of sensitivity and reproducibility the three single-shot ATP hygiene-monitoring systems investigated, with the IDEXX LIGHTNING being the best, followed by the Biotrace UNILITE Xcel, and then the charm LUMINOMETER K, PocketSwab.

  9. Diagnostic laparoscopy-assisted cholangiography in infants with prolonged jaundice.

    PubMed

    Okazaki, Tadaharu; Miyano, Go; Yamataka, Atsuyuki; Kobayashi, Hiroyuki; Koga, Hiroyuki; Lane, Geoffrey J; Miyano, Takeshi

    2006-02-01

    Cholangiography is often crucial for establishing the definitive cause of neonatal jaundice. We present our protocol for using laparoscopy-assisted cholangiography in infants with prolonged jaundice and discuss its benefits. Firstly, a 5 mm supra-umbilical trocar is introduced to create a port for a 0 degrees laparoscope. A 5 mm trocar is then inserted through a right subcostal incision to allow the liver and gallbladder to be visualized. If the gallbladder is of good size, the fundus is exteriorized through the right subcostal trocar site and a catheter is inserted into the gallbladder for cholangiography. If the gallbladder is atretic, the fundus is not exteriorized and a laparotomy is performed for open intraoperative cholangiography because the lumen of an atretic gallbladder is usually not fully patent and cholangiography through its exteriorized fundus often fails. We reviewed 18 jaundiced infants thought to have biliary atresia (BA) who had laparoscopy-assisted cholangiography. At laparoscopy, four patients had good sized gallbladders and minimal to mild liver fibrosis. They underwent cholangiography via the exteriorized fundus, and BA in two cases and biliary hypoplasia in two cases were identified. The remaining 14 had atretic gallbladders and varying degrees of liver fibrosis. Cholangiography via the exteriorized fundus was performed in one patient, but failed and converted to open cholangiography. Open intraoperative cholangiography identified BA in all 14 cases. All BA cases progressed to Kasai portoenterostomy directly after diagnosis. Laparoscopy is used to determine the type of cholangiography to be performed based on the appearance of the gallbladder and this simple, accurate, and safe protocol allows the anatomical structure of the biliary tree to be obtained accurately with minimal surgical intervention.

  10. Small-incision access retroperitoneoscopic technique (SMART) pyeloplasty in adult patients: comparison of cosmetic and post-operative pain outcomes in a matched-pair analysis with standard retroperitoneoscopy: preliminary report.

    PubMed

    Pini, Giovannalberto; Goezen, Ali Serdar; Schulze, Michael; Hruza, Marcel; Klein, Jan; Rassweiler, Jens Jochen

    2012-10-01

    To present small-incision access retroperitoneoscopic technique pyeloplasty (SMARTp), a novel mini-laparoscopic approach for management of uretero-pelvic junction obstruction (UPJO) in adults including comparison with the standard retroperitoneoscopic technique (SRTp). In a non-randomised study, we matched 12 adult patients treated from August to November 2010 by SMARTp with 12 patients treated with SRTp from January to November 2010. Mini-laparoscopic retroperitoneal space was created with a home-made 6-mm balloon trocar. One 6-mm (for 5-mm 30° telescope) and two 3.5-mm trocars (for 3-mm working instrument) were used. SRTp was performed with 11- and 6-mm trocar. Primary endpoints included evaluation of cosmetic appearance and post-operative pain evaluated respectively by the patient and observer scar assessment scale (POSAS) and analogue visual scale (VAS). Secondary endpoints were comparison between operative and functional parameters. Cosmetic cumulative results were statistically significant in favour of SMARTp (POSAS: 37.9 vs. 52.4; P = 0.002). A better trend has been shown by post-operative pain (first to fourth day VAS), although not statistically significant (4.2 vs. 4.9, P = 0.891). No differences were recorded in terms of operative time, pre- and post-operative Hb difference, DJ-stent removal and resistive index (RI) improvement. The SMARTp group showed a faster drain removal (2.4 vs. 3.4 day, P = 0.004) and discharge (4.5 vs. 5.4 day P = 0.017). Preliminary data support SMARTp as safe procedures in experienced hands, providing better cosmetic results compared to SRTp. Further studies and clinical randomised trial performed in a larger population sample are requested.

  11. Single-Incision Laparoscopic Anterior Resection Using a Curved Stapler.

    PubMed

    Watanabe, Jun; Ota, Mitsuyoshi; Suwa, Yusuke; Ishibe, Atsushi; Masui, Hidenobu; Nagahori, Kaoru

    2016-11-01

    Single-incision laparoscopic colectomy is technically limited because of such factors as instrument crowding, in-line viewing, and insufficient countertraction. In particular, it is technically difficult to cut the distal rectum from the umbilicus using an articulating linear stapler in single-incision laparoscopic anterior resection. After treating the mesorectum, the 5-mm trocar is replaced with a 12-mm trocar. The cartridge of the curved stapler is mounted while the shaft of the stapler is inserted into the 12-mm port extracorporeally. The curved stapler is inserted through the umbilical incision with the cartridge. A multichannel port is then mounted, and the abdominal cavity is reinsufflated. The curved stapler can then be operated intracorporeally. This procedure facilitates the vertical dissection of the rectum from the umbilicus. A total of 27 consecutive patients were analyzed in this study. All the procedures were safely performed without any complications. The median distance from the peritoneal reflection to the transection point of the distal bowel in single-incision laparoscopic anterior resection was 5.0 cm (range, -2.0 to 15.0). One stapler firing was required to achieve distal bowel division in 26 patients (96.3 %), whereas 2 firings were required in 1 patient (3.7 %). The median distal margin was 7.0 cm (range, 3.0-13.0). The time from the insertion of the stapler to transection was 180 seconds (range, 100-420). There were no cases of anastomotic leakage. In single-incision laparoscopic anterior resection, it is feasible to perform rectal transection from the umbilicus by using a curved stapler. This technique may allow for the omission of 1 trocar from the operation.

  12. Grid impacts of wind power: a summary of recent studies in the United States

    NASA Astrophysics Data System (ADS)

    Parsons, Brian; Milligan, Michael; Zavadil, Bob; Brooks, Daniel; Kirby, Brendan; Dragoon, Ken; Caldwell, Jim

    2004-04-01

    Several detailed technical investigations of grid ancillary service impacts of wind power plants in the United States have recently been performed. These studies were applied to Xcel Energy (in Minnesota) and PacifiCorp and the Bonneville Power Administration (both in the northwestern United States). Although the approaches vary, three utility time frames appear to be most at issue: regulation, load following and unit commitment. This article describes and compares the analytic frameworks from recent analysis and discusses the implications and cost estimates of wind integration. The findings of these studies indicate that relatively large-scale wind generation will have an impact on power system operation and costs, but these impacts and costs are relatively low at penetration rates that are expected over the next several years. Published in 2004 by John Wiley & Sons, Ltd.

  13. Wind-To-Hydrogen Project: Electrolyzer Capital Cost Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saur, G.

    This study is being performed as part of the U.S. Department of Energy and Xcel Energy's Wind-to-Hydrogen Project (Wind2H2) at the National Renewable Energy Laboratory. The general aim of the project is to identify areas for improving the production of hydrogen from renewable energy sources. These areas include both technical development and cost analysis of systems that convert renewable energy to hydrogen via water electrolysis. Increased efficiency and reduced cost will bring about greater market penetration for hydrogen production and application. There are different issues for isolated versus grid-connected systems, however, and these issues must be considered. The manner inmore » which hydrogen production is integrated in the larger energy system will determine its cost feasibility and energy efficiency.« less

  14. Clinical Record of Emergency Vascular Access Using Adult Intraosseous (IO) Devices

    DTIC Science & Technology

    2004-09-01

    which were disposable and similar in design to the reusable trocared needles of Paper and Bailey needles ( Papper , 1942; Bailey 1944; Glaeser, 1993...shock in a swine model. J Trauma 1993 Mar;34(3):422- 8. Papper , EM. The bone marrow route for injecting fluids and drugs into the general circulation

  15. Two-trocar needlescopic approach to incarcerated inguinal hernia in children.

    PubMed

    Shalaby, Rafik; Shams, Abdul Moniem; Mohamed, Soliman; el-Leathy, Mohamed; Ibrahem, Medhat; Alsaed, Gamal

    2007-07-01

    Many studies described the safety and effectiveness of laparoscopy in the treatment of inguinal hernia in children. Needlescopic techniques have been recently used in repairing inguinal hernias, which made this type of surgery more cosmetic and less invasive. However, few reports have described its role in the treatment of incarcerated inguinal hernia. The aim of this study was to assess the feasibility and outcome of needlescopy in the treatment of incarcerated inguinal hernia in children. A total of 250 children, comprising 190 boys and 60 girls, who presented with incarcerated inguinal hernia were analyzed. Their ages ranged from 6 months to 6 years (mean age, 2 years). In 170 (68%) cases, manual reduction was successful. One hundred of these patients were subjected to definitive surgery in the same day, whereas the remaining 70 patients were subjected to needlescopy 1 to 3 days later. In 80 (32%) cases, external manual reduction was unsuccessful. These children were subjected to urgent needlescopic reduction and herniorrhaphy. The incarcerated herniae were easily reduced and the contents thoroughly inspected under direct vision. Then the hernia was repaired in the same setting. In all patients, there was no need to convert the procedure to an open approach. Immediate needlescopic herniorrhaphy in the same session was added without significant increase in operative time. The mean operative time is 10 minutes. There were no intraoperative complications. The study showed that needlescopic approach to incarcerated inguinal hernia in children is feasible, safe, easy, and preferable to the open surgery. In addition to reduction of incarcerated hernial contents under direct vision, it allows definitive treatment of hernial defect at the same time without significant increase in operative time and hospital stay.

  16. Transjejunal Extraction of Gallbladder After Mini-Laparoscopic Cholecystectomy in Patients with Previous Roux-en-Y Gastric Bypass: A Small Case Series.

    PubMed

    Kayaalp, Cuneyt; Tardu, Ali; Yagci, Mehmet Ali; Sumer, Fatih

    2015-07-01

    The length of incisions on the abdominal wall directly correlates with wound-related morbidities and patient comfort. Both mini-laparoscopy (only ≤5-mm trocars) and natural orifice specimen extraction avoid larger abdominal incisions. This study described a new natural orifice translumenal endoscopic surgery (NOTES(®); American Society for Gastrointestinal Endoscopy [Oak Brook, IL] and Society of American Gastrointestinal and Endoscopic Surgeons [Los Angeles, CA]) cholecystectomy technique by combination of these two advanced laparoscopic techniques for cholelithiasis in patients who had prior laparoscopic Roux-en-Y gastric bypass (LRYGB) for obesity. Three patients (two males, one female; 39, 62, and 34 years old, respectively) were admitted with symptomatic cholelithiasis (multiple millimeter-sized gallstones), and all had previously had LRYGB. They were treated by mini-laparoscopic cholecystectomy using three 5-mm trocars. The gallbladder was removed through the dilated efferent limb of the jejunum, 5 cm distal from the gastrojejunostomy. Transjejunal extraction was performed under endoscopic guidance. The gallbladder in the jejenum was passed through the anastomosis and extracted with an endoscopic snare by the transoral way. The enterotomy was closed intracorporeally. There was no conversion or additional trocar requirement. All the procedures were completed successfully without problems. Respective operating times were 95, 75, and 120 minutes. Only 1 patient required postoperative analgesic; the others did not. The patients started to get a liquid diet on the night of surgery and were discharged on Days 1, 1, and 2, respectively, with normal diet recommendations. There were no morbidities. Mini-laparoscopic cholecystectomy is technically feasible in patients with previous LRYGB. Prior LRYGB was not an obstacle for transoral specimen extraction. The dilated efferent jejunal limb is a good alternative route for natural orifice specimen extraction. This

  17. Stereoscopic three-dimensional images of an anatomical dissection of the eyeball and orbit for educational purposes.

    PubMed

    Matsuo, Toshihiko; Takeda, Yoshimasa; Ohtsuka, Aiji

    2013-01-01

    The purpose of this study was to develop a series of stereoscopic anatomical images of the eye and orbit for use in the curricula of medical schools and residency programs in ophthalmology and other specialties. Layer-by-layer dissection of the eyelid, eyeball, and orbit of a cadaver was performed by an ophthalmologist. A stereoscopic camera system was used to capture a series of anatomical views that were scanned in a panoramic three-dimensional manner around the center of the lid fissure. The images could be rotated 360 degrees in the frontal plane and the angle of views could be tilted up to 90 degrees along the anteroposterior axis perpendicular to the frontal plane around the 360 degrees. The skin, orbicularis oculi muscle, and upper and lower tarsus were sequentially observed. The upper and lower eyelids were removed to expose the bulbar conjunctiva and to insert three 25-gauge trocars for vitrectomy at the location of the pars plana. The cornea was cut at the limbus, and the lens with mature cataract was dislocated. The sclera was cut to observe the trocars from inside the eyeball. The sclera was further cut to visualize the superior oblique muscle with the trochlea and the inferior oblique muscle. The eyeball was dissected completely to observe the optic nerve and the ophthalmic artery. The thin bones of the medial and inferior orbital wall were cracked with a forceps to expose the ethmoid and maxillary sinus, respectively. In conclusion, the serial dissection images visualized aspects of the local anatomy specific to various procedures, including the levator muscle and tarsus for blepharoptosis surgery, 25-gauge trocars as viewed from inside the eye globe for vitrectomy, the oblique muscles for strabismus surgery, and the thin medial and inferior orbital bony walls for orbital bone fractures.

  18. Ivor Lewis esophagectomy with manual esogastric anastomosis by thoracoscopy in prone position and laparoscopy.

    PubMed

    Cadière, G B; Dapri, G; Himpens, J; Fodderie, L; Rajan, A

    2010-06-01

    Only a few authors have reported the technique of Ivor Lewis esophagectomy by minimally invasive means, and anastomosis was usually performed by a circular stapler. We report an Ivor Lewis esophagogastrectomy with manual esogastric anastomosis performed by thoracoscopy in the prone position. An adenocarcinoma of the distal esophagus without lymph nodes invasion was diagnosed in a 51-year-old man. General anesthesia and double-lumen endotracheal tube intubation were used. First the patient was placed in the supine position, and five abdominal trocars were placed. Celiac lymphadenectomy was performed with section of the left gastric vessels. A wide Kocher maneuver and pyloroplasty were performed. A wide gastric tube was performed and advanced through the hiatus into the right chest. Subsequently the patient was placed in the prone position. Three trocars (two 5-mm and one 11-mm) were placed on the posterior axillary line in the fifth, seventh, and ninth right intercostal space. The intrathoracic esophagus was dissected. Mediastinal lymphadenectomy with en bloc resection of the left inferior mediastinal pleura was performed. The azygos vein was sectioned, and the esophagus was transected by scissors 1-cm cranial to the azygos vein. A completely thoracoscopic manual double-layer anastomosis was performed by using running sutures with PDS 2/0 externally and Maxon 4/0 internally. Finally the patient was replaced in the supine position to retrieve the specimen through a suprapubic incision, and the gastric tube was fixed to the hiatus. Thoracoscopy lasted 157' (anastomosis 40'), laparoscopy 160', and second laparoscopy 20'. Blood loss was estimated at 170 ml. The gastrograffin swallow on postoperative day 4 showed absence of stenosis and leak. The patient was discharged on postoperative day 6. Thoracoscopy in the prone position allows the surgeon to perform a thoracoscopic esogastric anastomosis completely handsewn without selective lung desufflation, and using only three

  19. Single-incision laparoscopic cholecystectomy for biliary dyskinesia in children: a simple, safe, and inexpensive technique.

    PubMed

    Leinwand, Michael J; Elgamal, Mohamed H

    2013-04-01

    To evaluate a low-cost technique for single-incision laparoscopic cholecystectomy (SILC) in children with biliary dyskinesia. Eighteen children with biliary dyskinesia underwent SILC between March and September 2010. Two 5-mm trocars and a directly introduced grasper were inserted through a 2-cm vertical transumbilical incision. Instrument collisions were minimized by using low-profile trocars and a bariatric laparoscope with a right-angle light adaptor. An internally anchored retracting device suspended the gallbladder, obviating the need for an additional trocar. No other special equipment was used. There were 15 girls and 3 boys with a mean age of 15.9 years (range, 9-18 years). Sixteen (88.9%) underwent true SILC. One patient was converted to a four-port laparoscopic procedure because of uncertainty of ductal anatomy. Another required a 5-mm subxiphoid port for liver retraction. Mean operative time was 82 minutes (range, 42-105 minutes): 94 minutes (range, 75-105 minutes) for the first 6 patients, 85 minutes (range, 60-102 minutes) for the second 6, and 68 minutes (range, 42-90 minutes) for the last 6. Operative times between the first and last groups were significantly different (P=.02). Sixteen patients were discharged home the following day and the remaining 2 on the second postoperative day. There were no complications. The hospital costs of the disposable equipment needed to perform SILC at our institution was $205.05 less than that needed for the four-port operation ($516.32 versus $721.37), a 28.4% savings. SILC is safe and feasible in children with biliary dyskinesia. The operative time decreased with experience. The disposable equipment needed was less expensive than that used for the standard laparoscopic technique.

  20. Surgical treatment of gastroesophageal reflux disease and upside-down stomach using the Da Vinci robotic system. A prospective study.

    PubMed

    Hartmann, Jens; Jacobi, Christoph A; Menenakos, Charalambos; Ismail, Mahmoud; Braumann, Chris

    2008-03-01

    So far, the impact of telematic surgical approach in Gastroesophageal Reflux Disease (GERD) is still obscure. In this prospective study, we analyzed the Da Vinci Intuitive Surgical robotic system for antireflux surgery. In April 2003, we set up a pilot study to evaluate the efficacy of laparoscopic telerobotic surgery using the three-arm Da Vinci system. Optimal trocar positions, operating and setup times, conversion rate, intraoperative complications, and perioperative morbidity, as well as mortality rate, were analyzed. The median age was 53 years (range 25-74) in 118 patients (52 female/66 male). In 17 patients, an upside-down stomach- and in 101 GERD was surgical indication. The median operating time has been reduced from 105 min to 91 min after 40 procedures and setup time from 24.5 min to 10.4 min after 10 procedures. The system is safe and it seems to be superior to traditional laparoscopy during dissection in the esophageal hiatus region. This compensates long setup- and operating times. Disadvantages are the high costs, the time to master the setup/system and the necessity of exact trocar positioning.

  1. Thoracoscopic pneumonectomy for severe bronchiectasis in a 9-year-old female.

    PubMed

    Anselmo, Dean M; Perez, Iris A; Shaul, Donald B

    2008-10-01

    Thoracoscopic total pneumonectomy has not been previously described in the pediatric surgical literature. In this paper, we describe a case of pneumonectomy performed through a minimally invasive approach in a 9-year-old female with Down's syndrome and gastroesophageal reflux disease. The patient suffered from multiple recurrent aspiration pneumonias, which progressed to bronchiectasis of the entire left lung. As a result, the patient was hypoxemic and required continuous supplemental oxygen. Preoperative perfusion scans showed diminished perfusion of the left lung. Thoracoscopy was performed by using 3-5 mm trocars and one 12-mm trocar. Insufflation pressure was maintained at 5 mm Hg. Dissection was performed at the hilum by using hook electrocautery and the LigaSure device (ValleyLab, Boulder, CO). The pulmonary artery, veins, and left mainstem bronchus were sequentially divided by using a 35-mm ENDO GIA vascular stapler (Ethicon Endo-Surgery, Cincinnati, OH). There were no intraoperative complications. Eight months following surgery, her health is improved and she no longer requires supplemental oxygen. Thoracoscopic pneumonectomy is a safe, technically feasible approach for severe bronchiectasis in children.

  2. Cooled High-temperature Radial Turbine Program 2

    NASA Technical Reports Server (NTRS)

    Snyder, Philip H.

    1991-01-01

    The objective of this program was the design and fabrication of a air-cooled high-temperature radial turbine (HTRT) intended for experimental evaluation in a warm turbine test facility at the LeRC. The rotor and vane were designed to be tested as a scaled version (rotor diameter of 14.4 inches diameter) of a 8.021 inch diameter rotor designed to be capable of operating with a rotor inlet temperature (RIT) of 2300 F, a nominal mass flow of 4.56 lbm/sec, a work level of equal or greater than 187 Btu/lbm, and efficiency of 86 percent or greater. The rotor was also evaluated to determine it's feasibility to operate at 2500 F RIT. The rotor design conformed to the rotor blade flow path specified by NASA for compatibility with their test equipment. Fabrication was accomplished on three rotors, a bladeless rotor, a solid rotor, and an air-cooled rotor.

  3. Single-incision laparoscopic cholecystectomy with needle graspers.

    PubMed

    Sumiyoshi, Kinjiro; Sato, Norihiro; Akagawa, Shin; Hirano, Tatsuya; Koikawa, Kazuhiro; Horioka, Kohei; Ozono, Keigo; Fujiwara, Kenji; Tanaka, Masao; Sada, Masayuki

    2012-01-01

    Single-incision laparoscopic cholecystectomy (SILC) is a promising alternative to standard multi-incision laparoscopic cholecystectomy (LC). However, generalization of SILC is still hampered by technical difficulties mainly associated with the lack of trocars used for retraction of the gallbladder. We therefore developed a modified method of SILC with the use of needle graspers (SILC-N) for optimal retraction and exposure. In addition to two trocars inserted through a single transumbilical incision, two needle ports were placed on the right subcostal and lateral abdominal wall, through which needle graspers were used for retraction of the gallbladder. Since December, 2009, 12 patients with symptomatic cholelithiasis were treated by SILC-N. SILC-N was successfully performed in all but one patient requiring a conversion to the 4-port LC with a mean operative time of 71.5 (48-107) minutes. None of the patients experienced intraoperative or postoperative complications. The transumbilical incision and pinholes for needle graspers were almost invisible on discharge. Our preliminary results suggest that SILC-N is a simple, safe and feasible technique of cholecystectomy offering similar postoperative recovery and better cosmetic outcome as compared to conventional LC.

  4. Tube Thoracostomy: Complications and Its Management

    PubMed Central

    Kesieme, Emeka B.; Dongo, Andrew; Ezemba, Ndubueze; Irekpita, Eshiobo; Jebbin, Nze; Kesieme, Chinenye

    2012-01-01

    Background. Tube thoracostomy is widely used throughout the medical, surgical, and critical care specialities. It is generally used to drain pleural collections either as elective or emergency. Complications resulting from tube thoracostomy can occasionally be life threatening. Aim. To present an update on the complications and management of complications of tube thoracostomy. Methods. A review of the publications obtained from Medline search, medical libraries, and Google on tube thoracostomy and its complications was done. Results. Tube thoracostomy is a common surgical procedure which can be performed by either the blunt dissection technique or the trocar technique. Complication rates are increased by the trocar technique. These complications have been broadly classified as either technical or infective. Technical causes include tube malposition, blocked drain, chest drain dislodgement, reexpansion pulmonary edema, subcutaneous emphysema, nerve injuries, cardiac and vascular injuries, oesophageal injuries, residual/postextubation pneumothorax, fistulae, tumor recurrence at insertion site, herniation through the site of thoracostomy, chylothorax, and cardiac dysrhythmias. Infective complications include empyema and surgical site infection. Conclusion. Tube thoracostomy, though commonly performed is not without risk. Blunt dissection technique has lower risk of complications and is hence recommended. PMID:22028963

  5. Transillumination for needle localization in the larynx.

    PubMed

    Hoffman, Henry T; Dailey, Seth H; Bock, Jonathan M; Thibeault, Susan L; McCulloch, Timothy M

    2015-10-01

    Transillumination through laryngeal soft tissue may be used to direct percutaneous transcricothyroid membrane subepithelial needle placement in the larynx. Cadaver simulation (canine and human). Lighted devices, including sialendoscopes and fiberoptic cables, were tested as transilluminating obturators in trocars and needles through multiple studies to identify appropriate illumination, monitoring, and equipment for successful localization of needle/trocar tips placed within laryngeal tissue. Lighted 250-micron fiberoptic cables within 23-gauge needles were successfully placed percutaneously through the cricothyroid membrane and maneuvered submucosally into Reinke's space, the midlateral vocal fold, and through the thyroarytenoid gap with monitoring via flexible transnasal laryngoscopy. Technical adaptations in the course of study permitted successful simulation of clinical use in full cadaver study for accurate injection laryngoplasty, confirmed by laryngeal dissection following collagen injection. Small caliber fiberoptic cables are useful as transilluminating obturators to accurately direct needle position within laryngeal tissue. Clinical application of this new technique is anticipated to improve the accuracy of percutaneous needle localization in the larynx, as well as to assist in directed instrumentation of the larynx from an external approach. N/A. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Mobile in vivo camera robots provide sole visual feedback for abdominal exploration and cholecystectomy.

    PubMed

    Rentschler, M E; Dumpert, J; Platt, S R; Ahmed, S I; Farritor, S M; Oleynikov, D

    2006-01-01

    The use of small incisions in laparoscopy reduces patient trauma, but also limits the surgeon's ability to view and touch the surgical environment directly. These limitations generally restrict the application of laparoscopy to procedures less complex than those performed during open surgery. Although current robot-assisted laparoscopy improves the surgeon's ability to manipulate and visualize the target organs, the instruments and cameras remain fundamentally constrained by the entry incisions. This limits tool tip orientation and optimal camera placement. The current work focuses on developing a new miniature mobile in vivo adjustable-focus camera robot to provide sole visual feedback to surgeons during laparoscopic surgery. A miniature mobile camera robot was inserted through a trocar into the insufflated abdominal cavity of an anesthetized pig. The mobile robot allowed the surgeon to explore the abdominal cavity remotely and view trocar and tool insertion and placement without entry incision constraints. The surgeon then performed a cholecystectomy using the robot camera alone for visual feedback. This successful trial has demonstrated that miniature in vivo mobile robots can provide surgeons with sufficient visual feedback to perform common procedures while reducing patient trauma.

  7. Petition to Object to the Xcel Energy, Hayden Station, Hayden Colorado, Title V Operating Permit

    EPA Pesticide Factsheets

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  8. 77 FR 61592 - American Transmission Company LLC v. Midwest Independent Transmission System Operator, Inc., Xcel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-10

    ... facilities from the Twin Cities area in Minnesota to the Madison area in Wisconsin. ATCLLC certifies that...,. Northern States Power Company, a Wisconsin Corporation, Northern States Power Company, a Minnesota...., on behalf of its operating company affiliates Northern States Power Company Wisconsin (NSPW) and...

  9. New steps of robot-assisted radical prostatectomy using the extraperitoneal approach: a propensity-score matched comparison between extraperitoneal and transperitoneal approach in Japanese patients.

    PubMed

    Kurokawa, Satoshi; Umemoto, Yukihiro; Mizuno, Kentaro; Okada, Atsushi; Nakane, Akihiro; Nishio, Hidenori; Hamamoto, Shuzo; Ando, Ryosuke; Kawai, Noriyasu; Tozawa, Keiichi; Hayashi, Yutaro; Yasui, Takahiro

    2017-11-21

    Robot-assisted radical prostatectomy (RARP) is commonly performed using the transperitoneal (TP) approach with six trocars over an 8-cm distance in the steep Trendelenburg position. In this study, we investigated the feasibility and the benefit of using the extraperitoneal (EP) approach with six trocars over a 4-cm distance in a flat or 5° Trendelenburg position. We also introduced four new steps to the surgical procedure and compared the surgical results and complications between the EP and TP approach using propensity score matching. Between August 2012 and August 2016, 200 consecutive patients without any physical restrictions underwent RARP with the EP approach in a less than 5° Trendelenburg position, and 428 consecutive patients underwent RARP with the TP approach in a steep Trendelenburg position. Four new steps to RARP using the EP approach were developed: 1) arranging six trocars; 2) creating the EP space using laparoscopic forceps; 3) holding the separated prostate in the EP space outside the robotic view; and 4) preventing a postoperative inguinal hernia. Clinicopathological results and complications were compared between the EP and TP approaches using propensity score matching. Propensity scores were calculated for each patient using multivariate logistic regression based on the preoperative covariates. All 200 patients safely underwent RARP using the EP approach. The mean volume of estimated blood loss and duration of indwelling urethral catheter use were significantly lower with the EP approach than the TP approach (139.9 vs 184.9 mL, p = 0.03 and 5.6 vs 7.7 days, p < 0.01, respectively). No significant differences in the positive surgical margin were observed. None of the patients developed an inguinal hernia postoperatively after we introduced this technique. The EP approach to RARP was safely performed regardless of patient physique or contraindications to a steep Trendelenburg position. Our method, which involved using the EP approach

  10. An Isolator System for minimally invasive surgery: the new design

    PubMed Central

    Jansen, Frank-Willem; Dankelman, Jenny

    2010-01-01

    Background The risk of obtaining a postsurgical infection depends highly on the air quality surrounding the exposed tissue, surgical instruments, and materials. Many isolators for open surgery have been invented to create a contained sterile volume around the exposed tissue. With the use of an isolator, a surgical procedure can be performed outside sterile environments. The goal of this study was to design an Isolator System (IS) for standard laparoscopic instruments while instrument movements are not restricted. Methods The developed IS consists of a sleeve to protect the instrument shaft and tip and a special balloon to protect the incision and trocar tube. A coupling mechanism connected at the sleeve allows instrument changes without contamination of the isolated parts. Smoke tests were performed to show that outside air does not enter the new IS during a simulated laparoscopic procedure. Eight test runs and one baseline run inside a contained volume filled with thick smoke were performed to investigate whether smoke particles entered the Isolator System. Filters were used to identify smoke entering the Isolator System. Results Seven filters showed no trace of smoke particles. In one test run, a part of the IS loosened and a small brown spot was visible. The filter from the baseline run was completely covered with a thick layer of particles, proving the effectiveness of the test. During all test runs, the isolated instrument was successfully locked on and unlocked from the isolated trocar. Instrument movements gave no complications. After removal of the isolated instrument, it took three novices an average of 3.1 (standard deviation (SD), 0.7) seconds to replace it correctly on the isolated trocar. Conclusions The designed IS for laparoscopy can increase sterility in environments where sterility cannot be guaranteed. The current design is developed for laparoscopy, but it can easily be adapted for other fields in minimally invasive surgery. PMID:20108141

  11. Laparoendoscopic single site (LESS) cholecystectomy.

    PubMed

    Hodgett, Steven E; Hernandez, Jonathan M; Morton, Connor A; Ross, Sharona B; Albrink, Michael; Rosemurgy, Alexander S

    2009-02-01

    The journey from conventional "open" operations to truly "minimally invasive" operations naturally includes progression from operations involving multiple trocars and multiple incisions to operations involving access through the umbilicus alone. Laparoscopic operations through the umbilicus alone, laparoendoscopic single site surgery (LESS), offer improved cosmesis and hopes for less pain and improved recovery. This study was undertaken to evaluate our initial experience with LESS cholecystectomy and to compare our initial experience to concurrent outcomes with more conventional multiport, multi-incision laparoscopic cholecystectomy. All patients referred for cholecystectomy over a 6-month period were offered LESS. Outcomes, including blood loss, operative time, complications, and length of stay were recorded. Outcomes with our first LESS cholecystectomies were compared to an uncontrolled group of concurrent patients undergoing multiport, multi-incision laparoscopic cholecystectomy at the same hospital by the same surgeon. Twenty-nine patients of median age 50 years undergoing LESS cholecystectomy from November 2007 until May 2008 were compared to 29* patients, median age 48 years, undergoing standard multiport, multiple-incision laparoscopic cholecystectomy over the same time period. Median operative time for patients undergoing LESS cholecystectomy was 72 min and was not different from that of patients undergoing multiport, multi-incision laparoscopic cholecystectomy (p = 0.81). Median length of hospital stay was 1.0 day for patients undergoing LESS cholecystectomy and was not different from patients undergoing standard laparoscopic cholecystectomy (p = 0.46). Operative estimated blood loss was less than 100 cc for all patients. No patients undergoing attempted LESS cholecystectomy had conversions to "open" operations; two patients had an additional trocar(s) placed distant from the umbilicus to aid in exposure. Three patients undergoing LESS cholecystectomy had

  12. Effectiveness for pain after laparoscopic cholecystectomy of 0.5% bupivacaine-soaked Tabotamp placed in the gallbladder bed: a prospective, randomized, clinical trial.

    PubMed

    Feroci, Francesco; Kröning, Katrin Christel; Scatizzi, Marco

    2009-10-01

    Some scientific studies, with controversial results, have evaluated the efficacy in reducing pain of some different local anesthetic molecules, which were administered at different dosages and in different ways. The primary goal of this randomized, controlled, prospective study (Clinical Trials.gov ID NCT00599144) was to assess the effectiveness of 0.5% bupivacaine for pain control after video-laparoscopic cholecystectomy at its optimal dosage of 2 mg/kg infiltrated in the muscular fasciae of the trocars, or positioned in the gallbladder soaking a sheet of regenerated oxidized cellulose (Tabotamp). A total of 45 patients underwent elective video-laparoscopic cholecystectomy. They were randomized in three groups each made of 15 patients: group A (bupivacaine-soaked Tabotamp positioned in the gallbladder bed), group B (bupivacaine infiltrated in the muscular fasciae of the trocars' seat), group C (control group, not using local anesthetic). Six and twenty-four hours after the intervention, the nature of the pain and its intensity were recorded with the use of a Visual Analogue Scale (VAS). Six hours after the intervention, VAS average was 29.6 +/- 10.92 for group A, 25.86 +/- 16.06 for group B, and 36.13 +/- 16.62 for group C. At 24 h, we recorded 19.26 +/- 15.81, 18.53 +/- 12.3, and 20.46 +/- 20.08 for groups A, B, and C, respectively (p > 0.05). Comparing groups A and B between them and with the control group at 6 and 24 h, we deduced how only the first group showed a statistically significant advantage (p < 0.05) in reducing visceral and shoulder pain compared with the two other groups. Wound infiltration resulted in being statistically favorable in reducing parietal pain only when compared with Group A. For groups A and B, bupivacaine significantly reduced the use of postoperative pain killers. Bupivacaine, either infiltrated in trocars' wounds or kept soaked in a regenerated oxidized cellulose sheet positioned in the gallbladder bed, although safe and not

  13. Wake characteristics of wind turbines in utility-scale wind farms

    NASA Astrophysics Data System (ADS)

    Yang, Xiaolei; Foti, Daniel; Sotiropoulos, Fotis

    2017-11-01

    The dynamics of turbine wakes is affected by turbine operating conditions, ambient atmospheric turbulent flows, and wakes from upwind turbines. Investigations of the wake from a single turbine have been extensively carried out in the literature. Studies on the wake dynamics in utility-scale wind farms are relatively limited. In this work, we employ large-eddy simulation with an actuator surface or actuator line model for turbine blades to investigate the wake dynamics in utility-scale wind farms. Simulations of three wind farms, i.e., the Horns Rev wind farm in Denmark, Pleasant Valley wind farm in Minnesota, and the Vantage wind farm in Washington are carried out. The computed power shows a good agreement with measurements. Analysis of the wake dynamics in the three wind farms is underway and will be presented in the conference. This work was support by Xcel Energy (RD4-13). The computational resources were provided by National Renewable Energy Laboratory.

  14. Comparison of the effects of 23-gauge and 25-gauge microincision vitrectomy blade designs on incision architecture.

    PubMed

    Inoue, Makoto; Abulon, Dina Joy K; Hirakata, Akito

    2014-01-01

    To compare the effects of different 23- and 25-gauge microincision vitrectomy trocar cannula entry systems on incision architecture. We tested one ridged microvitreoretinal (MVR), one non-ridged MVR, one pointed beveled, and one round-tipped beveled blade (n=10 per blade design per incision type). Each blade's straight and oblique incision architecture was assessed in a silicone disc simulating the sclera. Wound leakage under pressure and endoscopic observations were conducted on sclerotomy sites of isolated porcine eyes (n=4 per blade design) after simulated vitrectomy. Differences in blade design created distinct incision architecture. Incisions were linear with the ridged MVR blade, flattened "M-shaped" with the non-ridged MVR blade, asymmetrical chevron-shaped with the pointed beveled blade, and curved with the round-tipped beveled blade. With the exception of oblique entry incision thickness, both MVR blade designs created thinner incisions than the beveled blades at entry and exit sites. Only the ridged MVR blade created incisions with no leakage. Vitreous incarceration was observed with all trocar cannula systems. Wound closure in porcine eyes was similar with all blades despite differences in incision architecture. Wound leakage occurred at low to moderate infusion pressures with most blades; no wound leakage was observed with ridged MVR blades.

  15. Comparison of the effects of 23-gauge and 25-gauge microincision vitrectomy blade designs on incision architecture

    PubMed Central

    Inoue, Makoto; Abulon, Dina Joy K; Hirakata, Akito

    2014-01-01

    Purpose To compare the effects of different 23- and 25-gauge microincision vitrectomy trocar cannula entry systems on incision architecture. Methods We tested one ridged microvitreoretinal (MVR), one non-ridged MVR, one pointed beveled, and one round-tipped beveled blade (n=10 per blade design per incision type). Each blade’s straight and oblique incision architecture was assessed in a silicone disc simulating the sclera. Wound leakage under pressure and endoscopic observations were conducted on sclerotomy sites of isolated porcine eyes (n=4 per blade design) after simulated vitrectomy. Results Differences in blade design created distinct incision architecture. Incisions were linear with the ridged MVR blade, flattened “M-shaped” with the non-ridged MVR blade, asymmetrical chevron-shaped with the pointed beveled blade, and curved with the round-tipped beveled blade. With the exception of oblique entry incision thickness, both MVR blade designs created thinner incisions than the beveled blades at entry and exit sites. Only the ridged MVR blade created incisions with no leakage. Vitreous incarceration was observed with all trocar cannula systems. Conclusion Wound closure in porcine eyes was similar with all blades despite differences in incision architecture. Wound leakage occurred at low to moderate infusion pressures with most blades; no wound leakage was observed with ridged MVR blades. PMID:25429201

  16. Refining the intraoperative measurement of the distal intrapancreatic part of a choledochal cyst during laparoscopic repair allows near total excision.

    PubMed

    Koga, Hiroyuki; Okawada, Manabu; Doi, Takashi; Miyano, Go; Lane, Geoffrey J; Yamataka, Atsuyuki

    2015-10-01

    During surgery for choledochal cyst (CC), any intrapancreatic CC (IPCC) must also be excised to prevent postoperative pancreatitis and stone formation. We report our technique for laparoscopic total IPCC excision (n = 16; mean age 6.0 years). We insert a fine ureteroscope with a light source into the opened CC through an extra 3.9-mm trocar placed in the epigastrium through a minute incision to identify the pancreatic duct orifice. By pulling the end of the ureteroscope emerging from the trocar gently to withdraw the tip from the pancreatic duct to where distal dissection was ceased under laparoscopic view, the IPCC can be measured. If longer than 5 mm, the distal CC is dissected further caudally until it is less than 5 mm. For accuracy, the distal CC is elevated with a suture that is exteriorized and clamped to provide constant traction. The IPCC was able to be measured in 11/16 (68 %). Initial lengths measured were 3-10 mm (5.2 ± 2.7 mm). Final IPCC were all 5 mm or less. Surgery was uncomplicated without any pancreatic duct injury and postoperative recovery was unremarkable. Follow-up MRI at 32 months showed no IPCC in any case. Measuring the IPCC enables total CC excision, thus reducing the potential for postoperative complications.

  17. Accidental ovarian autograft after a laparoscopic surgery: case report.

    PubMed

    Marconi, G; Quintana, R; Rueda-Leverone, N G; Vighi, S

    1997-08-01

    To report an autograft of ovarian tissue in the incision of the surgical trocar during laparoscopic surgery and to assess the potentiality of grafting of ovarian parenchyma in nonpelvic tissue in humans. A case report. Instituto de Fertilidad y Ginecología de Buenos Aires (IFER), Buenos Aires, Argentina. Infertile patient undergoing surgery due to an endometriotic cyst of the left ovary. Laparoscopic cystectomy. Accidental retention of a portion of the capsule and adjacent ovarian tissue of the endometrioma in SC cellular tissue. Months after surgery, a SC tumor was formed under the surgical incision. It was subsequently excised. Observation of tumor growth during menstrual cycles and ovulation induction; anatomopathologic study of the tissue after its extirpation. The tumor grew spontaneously in the periovulatory period and during treatments of ovulation induction. The anatomopathologic report of the tumor, removed 15 months after the first surgery, revealed functioning ovarian tissue with vessels of neoformation. This is the first description of autografted ovarian tissue in humans. We describe that the ovary can maintain its ovulatory function even in the absence of its pedicel. Also, we suggest that extirpation of surgical material through the incision of the trocar is not recommended, as the possibility of "sowing" or of autografts may occur.

  18. Single-incision laparoscopic appendectomy performed above the pubic symphysis - a new scarless approach.

    PubMed

    Yu, J; Wang, Y N; Hu, Y F; Cheng, X; Zhen, L; Li, G X

    2011-01-01

    The three-port method is commonly used for laparoscopic appendectomy. To obtain a better cosmetic result, we have selected the single-incision laparoscopic appendectomy to be performed above the pubic symphysis. We performed six single-incision laparoscopic appendectomies above the pubic symphysis. During each operation, a 2 cm transverse incision was made in the pubic hair area 3-4 cm above the pubic symphysis. A 5 mm trocar was then placed as an observation port with another two 5 mm trocars as main- and side-operating ports. The laparoscopic appendectomy was performed using this single-incision method. Six patients (five male and one female; body mass indexes of 18.07, 19.27, 21.67, 18.34, 26.83 and 22.46 kg/m(2), respectively) underwent successful single-incision laparoscopic appendectomy above the pubic symphysis. Operating times were recorded at 55, 58, 47, 51, 42 and 33 minutes, the corresponding post-operative anal ventilation times were 25, 24, 22, 18, 7 and 10 hours, while post-operative hospitalization periods stand at 3, 5, 2, 1, 3 and 2 days, respectively. No complications occurred during or post-operation. Our initial work shows that a single-incision laparoscopic appendectomy performed above the pubic symphysis is feasible and safe and yields excellent post-operative cosmetic results.

  19. 77 FR 10489 - Xcel Energy Services Inc., Northern States Power Company v. American Transmission Company, LLC...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-22

    ... 145 mile, 345 kV electric transmission line connecting NSPW's facilities near La Crosse, Wisconsin, with ATC's facilities near Madison, Wisconsin. XES and NSPW request that the Commission (1) find that... and conditions for the shared ownership and construction of the La Cross-Madison Line. XES and NSPW...

  20. An alternative gallbladder extraction technique in laparoscopic cholecystectomy.

    PubMed

    Tang, C N; Wong, D C T

    2006-05-01

    In this era of minimally invasive surgery, the challenge remains in finding techniques to reduce access trauma in terms of fewer and smaller size trocar ports. Our new described technique will allow a smaller subxiphoid port to be used to achieve extraction of the gallbladder without the need to change to a 5 mm laparoscope. We believe this method is easy to learn, safe and with no observable complications from our experience.

  1. One trocar needlescopic assisted inguinal hernia repair in children: a novel technique.

    PubMed

    Shalaby, Rafik; Elsayaad, Ibrahim; Alsamahy, Omar; Ibrahem, Refaat; El-Saied, Adham; Ismail, Maged; Shamseldin, Abdelmoniem; Shehata, Sameh; Magid, Mohamad

    2017-08-31

    Inguinal hernia repair using a percutaneous internal ring suturing technique is an effective alternative technique to conventional laparoscopic hernia repair. It is one of the most commonly used approaches for laparoscopic hernia repair in children. However, most percutaneous techniques have utilized extracorporeal knotting of the suture and burying the knot subcutaneously. This approach has several drawbacks. The aim of this study is to present a modified technique for single cannula needlescopic assisted hernia repair in children. Three-hundred and fifty-seven patients with 397 indirect inguinal hernias underwent a one port needlescopic assisted inguinal hernia repair. The open internal inguinal ring [IIR] was closed using an 18-gauge epidural needle [EN], a 14-gauge venous access cannula [VAC], and a homemade suture device. Saline was injected extraperitoneally around the IIR for hydrodissection. The main outcome measurements were: feasibility, safety of the technique, operative time, recurrence rate, and cosmetic results. This prospective study was conducted on 357 patients at Al-Azhar, Alexandria, and Mansoura University Hospitals during the period from June 2012 to October 2015. There were 286 males and 71 females. The mean age was 2.6±1.3years (range=4months to 6years). One-hundred and ninety-eight patients presented with a right-sided inguinal hernia, 119 patients with a left-sided hernia, and 40 patients with bilateral inguinal hernia. The mean operative time was 12.6±1.7min (range=8-15min) for unilateral cases and 18.6±1.7min (range=14-20min) for the bilateral repairs. No wound complications or umbilical hernias developed. The mean follow-up period was 18.6±1.2months (range=11-36months). During the follow-up period, no recurrence was detected, and the scars were nearly invisible. This preliminary study shows that a single port needlescopic assisted hernia repair in infants and children is a very promising technique to achieve nearly scarless surgery. The procedure is very safe, rapid, easy to learn, and reproducible. Published by Elsevier Inc.

  2. Automated real time peg and tool detection for the FLS trainer box.

    PubMed

    Nemani, Arun; Sankaranarayanan, Ganesh

    2012-01-01

    This study proposes a method that effectively tracks trocar tool and peg positions in real time to allow real time assessment of the peg transfer task of the Fundamentals of Laparoscopic Surgery (FLS). By utilizing custom code along with OpenCV libraries, tool and peg positions can be accurately tracked without altering the original setup conditions of the FLS trainer box. This is achieved via a series of image filtration sequences, thresholding functions, and Haar training methods.

  3. [Fortuitous discovery of gallbladder cancer].

    PubMed

    Chiche, L; Metairie, S

    2001-12-01

    The prognosis of gallbladder cancer is basically dependent on the histological stage at diagnosis. In practice, the discovery of a small cancer of the bladder, generally during cholecystectomy give the patient a better care for curative treatment. The advent of laparoscopy has increased the number of cholecstectomies and could increase the frequency of this situation but also raises the difficult problem of metastatic dissemination. In the literature the figures on parietal metastasis after laparoscopy have ranged from 125% to 19%. The median delay to diagnosis of recurrence is 6 months. The cause of this phenomenon (role of the pneumoperitoneum) remains poorly elucidated. Risk factors for the development of a metastasis on the trocar orifice are: rupture of the gallbladder perioperatively and extraction of the gallbladder without protection. It is important to keep in mind this exceptional but serious risk and apply rigorous operative technique. In case of suspected gallbladder we do not advocate laparoscopy. Surgery (hepatectomy, lymphodenectomy, possibly resection of the biliary tract) would be indicted for all stages except pTis and T1a, taking into consideration the localization of the tumor and the patient's general status. It is also classical to recommend resection of the trocar orifices after laparoscopic cholecystectomy. There is a dual challenge today for small-sized gallbladder cancer: improving treatment and avoiding poorer prognosis due to the specific problems raised by laparoscopy.

  4. LESS living donor nephrectomy: Surgical technique and results

    PubMed Central

    Alessimi, Abdullah; Adam, Emilie; Haber, Georges-Pascal; Badet, Lionel; Codas, Ricardo; Fehri, Hakim Fassi; Martin, Xavier; Crouzet, Sébastien

    2015-01-01

    Purpose: We present the findings of 50 patients undergoing pure trans-umbilical laparo-endoscopic single-site surgery (LESS) living donor nephrectomy (LDN), between February 2010 and May 2014. Materials and Methods: Laparo-endoscopic single-site surgery LDN was performed through an umbilical incision. Different trocars were used, namely Gelpoint (Applied Mιdical, Rancho Santa Margarita, CA) SILS port (Covidien, Hamilton, Bermuda), R-port (Olympus Surgical, Orangeburg, NY) and standard trocars, inserted through the same skin incision but using separate fascial punctures. The standard laparoscopic technique was employed. The kidney was pre-entrapped in a retrieval bag and extracted trans-umbilically. Data were collected prospectively including questionnaires containing patient reported oral pain medication duration and time to recovery. Results: LESS LDN was successful in all patients. Mean warm ischemia time was 6.2 min (3–15), mean procedure time was 233.2 min (172–300), and hospitalization stay was 3.94 days (3–7) with a visual analogue pain score at discharge of 1.32 (0–3). No intraoperative complications occurred. The mean time of oral pain medication was 8.72 days (1–20) and final scar length was 4.06 cm (3–5). Each allograft was functional. Conclusion: Although challenging, trans-umbilical LESS LDN seems to be feasible and safe. Hence, LESS has the potential to improve cosmetic results and decrease morbidity. PMID:26229326

  5. The learning curve of laparoendoscopic single-site (LESS) cholecystectomy: definable, short, and safe.

    PubMed

    Hernandez, Jonathan; Ross, Sharona; Morton, Connor; McFarlin, Kellie; Dahal, Sujat; Golkar, Farhaad; Albrink, Michael; Rosemurgy, Alexander

    2010-11-01

    The applications of laparoendoscopic single-site (LESS) surgery, including cholecystectomy, are occurring quickly, although little is generally known about issues associated with the learning curve of this new technique including operative time, conversion rates, and safety. We prospectively followed all patients undergoing LESS cholecystectomy, and compared operations undertaken at our institutions in cohorts of 25 patients with respect to operative times, conversion rates, and complications. One-hundred fifty patients of mean age 46 years underwent LESS cholecystectomy. No significant differences in operative times were demonstrable between any of the 25-patient cohorts operated on at our institution. A significant reduction in operative times (p < 0.001) after completion of 75 LESS procedures was, however, identified with the experience of a single surgeon. No significant reduction in the number of procedures requiring an additional trocar(s) or conversion to open operations was observed after completion of 25 LESS cholecystectomies. Complication rates were low, and not significantly different between any 25-patient cohorts. For surgeons proficient with multi-incision laparoscopic cholecystectomy, the learning curve for LESS cholecystectomy begins near proficiency. Operative complications and conversions were infrequent and unchanged across successive 25-patient cohorts, and were similar to those reported for multi-incision laparoscopic cholecystectomy after the learning curve. Copyright © 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Petition to Object to Xcel Energy Pawnee Coal Fired Power Station, Brush, Colorado Title V Operating Permit

    EPA Pesticide Factsheets

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  7. Laparoscopic management of a ruptured benign dermoid cyst during advanced pregnancy.

    PubMed

    Roman, Horace; Accoceberry, Marie; Bolandard, Franck; Bourdel, Nicolas; Lenglet, Yann; Canis, Michel

    2005-01-01

    Benign cystic teratomas in pregnant women may be responsible for complications such as torsion, rupture and obstruction of labor. A woman in her 31st week of pregnancy with torsion of a large dermoid cyst and lipogranulomatosis peritonitis due to spilled cyst contents was managed laparoscopically with a favorable outcome. Trocar sites were selected according to the uterine size. Open laparoscopy allowed protection of the gravid uterus from penetrative injuries. Laparoscopic management of a voluminous adnexal mass may be safely performed during advanced pregnancy.

  8. CT-guided percutaneous ethanol injection with disposable curved needle for treatment of malignant liver neoplasms and their metastases in retroperitoneal lymph nodes

    PubMed Central

    Zuo, Chang-Jing; Wang, Pei-Jun; Shao, Cheng-Wei; Wang, Min-Jie; Tian, Jian-Ming; Xiao, Yi; Ren, Fang-Yuan; Hao, Xi-Yan; Yuan, Min

    2004-01-01

    AIM: To explore the feasibility of computed tomography (CT)-guided percutaneous ethanol injection (PEI) using a disposable curved needle for treatment of malignant liver neoplasms and their metastases in retroperitoneal lymph nodes. METHODS: CT-guided PEI was conducted using a disposable curved needle in 26 malignant liver tumors smaller than 5 cm in diameter and 5 lymph node metastases of liver cancer in the retroperitoneal space. The disposable curved needle was composed of a straight trocar (21G) and stylet, a disposable curved tip (25 G) and a fine stylet. For the tumors found in deep sites and difficult to reach, or for hepatic masses inaccessible to the injection using a straight needle because of portal vein and bile ducts, the straight trocar was used at first to reach the side of the tumor. Then, the disposable curved needle was used via the trocar. When the needle reached the tumor center, appropriate amount of ethanol was injected. For relatively large malignant liver tumors, multi-point injection was carried out for a better distribution of the ethanol injected throughout the masses. The curved needle was also used for treatment of the metastasis in retroperitoneal lymph nodes blocked by blood vessels and inaccessible by the straight needle. RESULTS: All of the 26 liver tumors received 2 or more times of successful PEI, through which ethanol was distributed throughout the whole tumor mass. Effect of the treatment was monitored by contrast-enhanced multi-phase CT and magnetic resonance imaging (MRI) examinations three months later. Of the 18 lesions whose diameters were smaller than 3 cm, the necrotic change across the whole mass and that in most areas were observed in 15 and 3 tumors, respectively. Among the 8 tumors sizing up to 5 cm, 5 were completely necrotic and 3 largely necrotic. Levels of tumor seromarkers were significantly reduced in some of the cases. In 5 patients with metastases of liver cancer in retroperitoneal lymph nodes who received 1

  9. Minilaparoscopic technique for inguinal hernia repair combining transabdominal pre-peritoneal and totally extraperitoneal approaches.

    PubMed

    Carvalho, Gustavo L; Loureiro, Marcelo P; Bonin, Eduardo A; Claus, Christiano P; Silva, Frederico W; Cury, Antonio M; Fernandes, Flavio A M

    2012-01-01

    Endoscopic surgical repair of inguinal hernia is currently conducted using 2 techniques: the totally extraperitoneal (TEP) and the transabdominal (TAPP) hernia repair. The TEP procedure is technically advantageous, because of the use of no mesh fixation and the elimination of the peritoneal flap, leading to less postoperative pain and faster recovery. The drawback is that TEP is not performed as frequently, because of its complexity and longer learning curve. In this study, we propose a hybrid technique that could potentially become the gold standard of minimally invasive inguinal hernia surgery. This will be achieved by combining established advantages of TEP and TAPP associated with the precision and cosmetics of minilaparoscopy (MINI). Between January and July 2011, 22 patients were admitted for endoscopic inguinal hernia repair. The combined technique was initiated with TAPP inspection and direct visualization of a minilaparoscopic trocar dissection of the preperitoneum space. A10-mm trocar was then placed inside the previously dissected preperitoneal space, using the same umbilical TAPP skin incision. Minilaparoscopic retroperitoneal dissection was completed by TEP, and the surgical procedure was finalized with intraperitoneal review and correction of the preperitoneal work. The minilaparoscopic TEP-TAPP combined approach for inguinal hernia is feasible, safe, and allows a simple endoscopic repair. This is achieved by combining features and advantages of both TAPP and TEP techniques using precise and sophisticated MINI instruments. Minilaparoscopic preperitoneal dissection allows a faster and easier creation of the preperitoneal space for the TEP component of the procedure.

  10. Patient-specific port placement for laparoscopic surgery using atlas-based registration

    NASA Astrophysics Data System (ADS)

    Enquobahrie, Andinet; Shivaprabhu, Vikas; Aylward, Stephen; Finet, Julien; Cleary, Kevin; Alterovitz, Ron

    2013-03-01

    Laparoscopic surgery is a minimally invasive surgical approach, in which abdominal surgical procedures are performed through trocars via small incisions. Patients benefit by reduced postoperative pain, shortened hospital stays, improved cosmetic results, and faster recovery times. Optimal port placement can improve surgeon dexterity and avoid the need to move the trocars, which would cause unnecessary trauma to the patient. We are building an intuitive open source visualization system to help surgeons identify ports. Our methodology is based on an intuitive port placement visualization module and atlas-based registration algorithm to transfer port locations to individual patients. The methodology follows three steps:1) Use a port placement visualization module to manually place ports in an abdominal organ atlas. This step generates port-augmented abdominal atlas. This is done only once for a given patient population. 2) Register the atlas data with the patient CT data, to transfer the prescribed ports to the individual patient 3) Review and adjust the transferred port locations using the port placement visualization module. Tool maneuverability and target reachability can be tested using the visualization system. Our methodology would decrease the amount of physician input necessary to optimize port placement for each patient case. In a follow up work, we plan to use the transferred ports as starting point for further optimization of the port locations by formulating a cost function that will take into account factors such as tool dexterity and likelihood of collision between instruments.

  11. Initial experience with laparoscopic inferior epigastric vessel ligation for delayed transverse rectus abdominus musculocutaneous flap breast reconstruction.

    PubMed

    Trus, Thadeus L; Collins, E Dale; Demas, Christopher; Kerrigan, Carolyn

    2007-04-01

    Transverse rectus abdominus musculocutaneous (TRAM) flap breast reconstruction provides excellent cosmetic results. Pedicle flap viability is greatly enhanced by prereconstruction inferior epigastric vessel ligation, which encourages collateral arterial flow (delayed TRAM). We report our initial experience with laparoscopic inferior epigastric vessel ligation. Prospective case series. Tertiary academic center. Female patients with breast cancer who chose pedicle TRAM reconstruction. Vessel ligations were performed 7 to 14 days prior to reconstruction. Abdominal access was achieved with a 3-mm umbilical trocar. A 5-mm trocar was placed lateral to the rectus sheath in the right lower quadrant. Five-millimeter Teflon clips were used to ligate the vessels near their origin. Complications of surgery and subsequent flap viability. From January 2001 to July 2006, 130 patients had laparoscopic inferior epigastric vessel ligation, of whom 123 patients had bilateral ligation. Additional procedures in conjunction with vessel ligation were performed in 38 patients (sentinel node biopsy [27], bilateral oophorectomy [7], liver biopsy [2], breast biopsy [1], and Nissen fundoplication [1]). Median operative time for those patients undergoing ligation only was 32.6 minutes (range, 14-121 minutes). The inferior epigastric vessels were not identified in 2 patients. Metastatic breast cancer involving the liver was found in 1 patient. There were no conversions or complications. Subsequent TRAM flap viability was excellent in most cases, with 1 complete flap necrosis in a high-risk, morbidly obese patient. Laparoscopic inferior epigastric vessel ligation for delayed TRAM flap breast reconstruction is a safe, effective procedure.

  12. Long-Term Outcomes of Single-Port Laparoscopic Placement of Peritoneal Dialysis Catheter.

    PubMed

    Pan, Alan; Poi, Mun J; Matos, Jesus; Jiang, Jenny S; Kfoury, Elias; Echeverria, Angela; Bechara, Carlos F; Lin, Peter H

    2016-07-01

    Laparoscopic insertion of peritoneal dialysis (PD) catheter has become a preferred method compared to the traditional open technique for PD catheter insertion. We retrospectively report the outcome of 1-port laparoscopic placement PD catheters in our institution. A total of 263 patients with end-stage renal disease who underwent single-trocar laparoscopic PD catheter insertion during a recent 6-year period were reviewed. Laparoscopic technique involves introducing a PD catheter over a stiff guidewire into the abdominal cavity through a 10-mm laparoscopic port. Pertinent clinical variables, procedural complications, and follow-up outcome were analyzed. There were 182 men and 81 women. The mean age was 56 years. Technical success was 95.8%. Catheter occlusion was the most common early complications (<6 months) that occurred in 4 (1.5%) patients. Late complications (> 6 months) including catheter occlusion, cuff extrusion, catheter leakage, catheter migration, infection, and hernia occurred in 5 patients (1.9%), 2 patients (0.8%), 3 patients (1.1%), 3 patients (1.1%), 6 patients (2.3%), and 4 patients (1.5), respectively. Mean follow-up time was 39 ± 18 months. Catheter survival rate at 1, 2, 3, 4, and 5 years was 96%, 94%, 90%, 85%, and 82%, respectively. Laparoscopic PD catheter implantation via a single-trocar utilizing a stiff guidewire technique is feasible and safe. This method can result in low complication and high catheter survival rate. © The Author(s) 2016.

  13. Petition to Object to the Cherokee Coal Fired Power Plant, Xcel Energy, Adams County, Colorado, Title V Permit

    EPA Pesticide Factsheets

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  14. Peitition to Object to the Valmont Coal Fired Power Plant, Xcel Energy, Boulder County, Colorado, Title V Permit

    EPA Pesticide Factsheets

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  15. Laparoscopic Double Discoid Resection With a Circular Stapler for Bowel Endometriosis.

    PubMed

    Kondo, William; Ribeiro, Reitan; Zomer, Monica Tessmann; Hayashi, Renata

    2015-01-01

    To demonstrate the technique of laparoscopic double discoid resection with a circular stapler for bowel endometriosis. Case report (Canadian Task Force classification III). Private hospital in Curitiba, Paraná, Brazil. A 33-year-old woman was referred to our service complaining about cyclic dysmenorrhea, dyspareunia, chronic pelvic pain, and cyclic dyschezia. Transvaginal ultrasound with bowel preparation showed a 6-cm endometriotic nodule at the retrocervical area, uterosacral ligaments, posterior vaginal fornix, and anterior rectal wall, infiltrating up to the submucosa, 5 cm far from the anal verge. Under general anesthesia, the patient was placed in the dorsal decubitus position with her arms alongside her body and her lower limbs in abduction. Pneumoperitoneum was achieved using a Veres needle placed at the umbilicus. Four trocars were placed: a 10-mm trocar at the umbilicus for the zero-degree laparoscope; a 5-mm trocar at the right anterosuperior iliac spine; a 5-mm trocar in the midline between the umbilicus and the pubic symphysis, approximately 8 to 10 cm inferior to the umbilical trocar; and a 5-mm trocar at the left anterosuperior iliac spine. The entire pelvis was inspected for endometriotic lesions, and all implants in the anterior compartment of the pelvis were resected. The lesions located at the ovarian fossae were completely removed. The ureters were identified bilaterally, and both para-rectal fossae were dissected. The right hypogastric nerve was released from the disease laterally. The lesion was separated from the retrocervical area, and the posterior vaginal fornix was resected (reverse technique), leaving the disease attached to the anterior surface of the rectum. The lesion was shaved off the anterior rectal wall using a harmonic scalpel. A x-shaped stitch was placed at the anterior rectal wall using 2-0 mononylon suture. A 33-mm circular stapler was placed transanally under laparoscopic control, and once it reached the area to be resected

  16. Turbulence effects on a full-scale 2.5 MW horizontal axis wind turbine

    NASA Astrophysics Data System (ADS)

    Chamorro, Leonardo; Lee, Seung-Jae; Olsen, David; Milliren, Chris; Marr, Jeff; Arndt, Roger; Sotiropoulos, Fotis

    2012-11-01

    Power fluctuations and fatigue loads are among the most significant problems that wind turbines face throughout their lifetime. Turbulence is the common driving mechanism that triggers instabilities on these quantities. We investigate the complex response of a full-scale 2.5 MW wind turbine under nearly neutral thermal stratification. The study is performed in the EOLOS Wind Energy Research Field Station of the University of Minnesota. An instrumented 130 meter meteorological tower located upstream of a Clipper Liberty C96 wind turbine is used to characterize the turbulent flow and atmospheric conditions right upstream of the wind turbine. High resolution and synchronous measurements of the wind velocity, turbine power and strain at the tower foundation are used to determine the scale-to-scale interaction between flow and the wind turbine. The structure of the fluctuating turbine power and instantaneous stresses are studied in detail. Important insights about the role of turbulent and coherent motions as well as strong intermittent gusts will be discussed. Funding was provided by Department of Energy DOE (DE-EE0002980) and Xcel Energy through the Renewable Development Fund (grant RD3-42).

  17. LAM-1 and FAT Genes Control Development of the Leaf Blade in Nicotiana sylvestris.

    PubMed Central

    McHale, NA

    1993-01-01

    Leaf primordia of the lam-1 mutant of Nicotiana sylvestris grow normally in length but remain bladeless throughout development. The blade initiation site is established at the normal time and position in lam-1 primordia. Anticlinal divisions proceed normally in the outer L1 and L2 layers, but the inner L3 cells fail to establish the periclinal divisions that normally generate the middle mesophyll core. The lam-1 mutation also blocks formation of blade mesophyll from distal L2 cells. This suggests that LAM-1 controls a common step in initiation of blade tissue from the L2 and L3 lineage of the primordium. Another recessive mutation (fat) was isolated in N. sylvestris that induces abnormal periclinal divisions in the mesophyll during blade initiation and expansion. This generates a blade approximately twice its normal thickness by doubling the number of mesophyll cell layers from four to approximately eight. Presumably, the fat mutation defines a negative regulator involved in repression of periclinal divisions in the blade. The lam-1 fat double mutant shows radial proliferation of mesophyll cells at the blade initiation site. This produces a highly disorganized, club-shaped blade that appears to represent an additive effect of the lam-1 and fat mutations on blade founder cells. PMID:12271096

  18. Centrifugal air-assisted melt agglomeration for fast-release "granulet" design.

    PubMed

    Wong, Tin Wui; Musa, Nafisah

    2012-07-01

    Conventional melt pelletization and granulation processes produce round and dense, and irregularly shaped but porous agglomerates respectively. This study aimed to design centrifugal air-assisted melt agglomeration technology for manufacture of spherical and yet porous "granulets" for ease of downstream manufacturing and enhancing drug release. A bladeless agglomerator, which utilized shear-free air stream to mass the powder mixture of lactose filler, polyethylene glycol binder and poorly water-soluble tolbutamide drug into "granulets", was developed. The inclination angle and number of vane, air-impermeable surface area of air guide, processing temperature, binder content and molecular weight were investigated with reference to "granulet" size, shape, texture and drug release properties. Unlike fluid-bed melt agglomeration with vertical processing air flow, the air stream in the present technology moved centrifugally to roll the processing mass into spherical but porous "granulets" with a drug release propensity higher than physical powder mixture, unprocessed drug and dense pellets prepared using high shear mixer. The fast-release attribute of "granulets" was ascribed to porous matrix formed with a high level of polyethylene glycol as solubilizer. The agglomeration and drug release outcomes of centrifugal air-assisted technology are unmet by the existing high shear and fluid-bed melt agglomeration techniques. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. A novel robotic right colectomy for colon cancer via the suprapubic approach using the da Vinci Xi system: initial clinical experience

    PubMed Central

    Lee, Hee Jae; Park, Jun Seok; Park, Soo Yeun; Kim, Hye Jin; Woo, In Teak; Park, In Kyu

    2018-01-01

    Purpose We developed a technique of totally-robotic right colectomy with D3 lymphadenectomy and intracorporeal anastomosis via a suprapubic transverse linear port. This article aimed to introduce our novel robotic surgical technique and assess the short-term outcomes in a series of five patients. Methods All colectomies were performed using the da Vinci Xi system. Four robot trocars were placed transversely in the supra pubic area. Totally-robotic right colectomy was performed, including colonic mobilization, D3 lymphadenectomy, and intra corporeal stapled functional anastomosis. The 2 middle suprapubic trocar incisions were then extended to retrieve the specimen. Results Five robotic right colectomies via the suprapubic approach were performed between August 2015 and February 2016. The mean operation time was 183 ± 29.37 minutes, and the mean estimated blood loss was 27 ± 9.75 mL. The time to clear liquid intake was 3 days in all patients, and the mean length of stay after surgery was 6.2 ± 0.55 days. No patient required conversion to conventional laparoscopic surgery. There were no perioperative complications. According to the pathology report, the mean number of harvested lymph nodes was 36.6 ± 4.45. Four patients were stage III, and 1 patient was stage II according to the 7th edition of the American Joint Committee on Cancer system. Conclusion Totally-robotic right colectomy via the suprapubic approach can be performed successfully in selected patients. Further comparative studies are required to verify the clinical advantages of our technique over conventional robotic surgery. PMID:29441337

  20. Short-Term Intraocular Pressure Rise during Locally Induced Force by Ophthalmologic Surgery Applications.

    PubMed

    Koelbl, Philipp Simon; Werner, Jens Ulrich; Enders, Christian; Lingenfelder, Christian; Koch, Frank H J; Hessling, Martin

    2018-05-31

    Surgical or diagnostic procedures are often accompanied by a short-term increase in intraocular pressure (IOP). A short-term increase in IOP can occur during refractive procedures, vitreoretinal surgery, transillumination, photocoagulation, or cryocoagulation. A porcine eye model was chosen (n = 89) to compile comparable study data and to de termine correlations between the force induced and the resulting intraocular pressure while excluding the effect of surgeons. The IOP was measured in the anterior chamber. IOP changes were induced by applying an external force and measured when using a cannula, trocar, and cryocoagulation (n = 32), and correlations between force and resulting IOP were assessed (n = 57). A correlation was noted between the force induced and the IOP increase, which showed a linear dependency. The insertion of a 29-G cannula caused a mean ΔIOP value of 49.1 ± 2.9 mm Hg and an external force of 0.76 N, and that of a 23-G trocar 344.4 ± 5.9 mm Hg and 6.09 N, respectively. The rise in IOP during a simulated cryocoagulation reached values between 57.3 ± 14.8 mm Hg (cryoprobe tip diameter: 0.9 mm) and 130.3 ± 2.9 mm Hg (cryoprobe tip diameter: 7.0 mm). The values of the forces applied can be converted into the resulting IOP based on the specific action. Surgical or diagnostic procedures should, therefore, be evaluated with regard to preexisting pathologies, such as glaucoma. © 2018 S. Karger AG, Basel.

  1. Simultaneous bilateral robotic partial nephrectomy: Case report and critical evaluation of the technique.

    PubMed

    Giberti, Claudio; Gallo, Fabrizio; Schenone, Maurizio; Cortese, Pierluigi

    2014-06-16

    We report our first simultaneous bilateral robot assisted partial nephrectomy (RAPN) in order to show and critically discuss the feasibility of this procedure. Materials and methods A 69-year-old male patient visited our department due to incidental finding of bilateral mesorenal small masses (2.5 cm on the right and 3.5 cm on the left) suspicious for malignancy. We started from the right side with patient in flank position. Port placement: 12-mm periumbilical camera port, two 8-mm robotic ports in wide ''V''configuration, additional 12 mm assistant port on the midline between the umbilicus and symphysis pubis. A right unclamping RAPN with sliding clip renorrhaphy was performed. The trocars were removed and the robot undocked. Without interrupting the anesthesiological procedures, the patient was reported in supine position and, after 180 degrees rotation of the surgical bed, was newly placed in contralateral flank position. Using both the previous periumbilical and midline ports, two other 8-mm robotic trocars were placed. The robot was then redocked and RAPN was also performed on the left side using the same previously reported technique. Results Total time: 285 min. Estimated blood losses: 150 cc. Postoperative period: uneventful. Pathological examination: bilateral renal cell carcinoma, negative surgical margins. Conclusions Our experience was encouraging and confirmed the feasibility and safety of this procedure. The planning of our technique was time and cost effective with cosmetic benefit for the patient. However, we think that an appropriate selection of the patients and a skill in robotic renal surgery are advisable before approaching this type of surgery.

  2. Simulated life-threatening emergency during robot-assisted surgery.

    PubMed

    Huser, Anna-Sophia; Müller, Dirk; Brunkhorst, Violeta; Kannisto, Päivi; Musch, Michael; Kröpfl, Darko; Groeben, Harald

    2014-06-01

    With the increasing use of robot-assisted techniques for urologic and gynecologic surgery in patients with severe comorbidities, the risk of a critical incidence during surgery increases. Due to limited access to the patient the start of effective measures to treat a life-threatening emergency could be delayed. Therefore, we tested the management of an acute emergency in an operating room setting with a full-size simulator in six complete teams. A full-size simulator (ISTAN, Meti, CA), modified to hold five trocars, was placed in a regular operating room and connected to a robotic system. Six teams (each with three nurses, one anesthesiologist, two urologists or gynecologists) were introduced to the scenario. Subsequently, myocardial fibrillation occurred. Time to first chest compression, removal of the robot, first defibrillation, and stabilization of circulation were obtained. After 7 weeks the simulation was repeated. The time to the start of chest compressions, removal of the robotic system, and first defibrillation were significantly improved at the second simulation. Time for restoration of stable circulation was improved from 417 ± 125 seconds to 224 ± 37 seconds (P=0.0054). Unexpected delays occurred during the first simulation because trocars had been removed from the patient but not from the robot, thus preventing the robot to be moved. Following proper training, resuscitation can be started within seconds. A repetition of the simulation significantly improved time for all steps of resuscitation. An emergency simulation of a multidisciplinary team in a real operating room setting can be strongly recommended.

  3. Our experience with a new instrument for laparoscopic gallbladder extraction, the "Bergetrokar".

    PubMed

    Höferlin, A; Höhle, K D

    1993-01-01

    Laparoscopic cholecystectomy has become a standardized technique within the last years. However, the extraction of the stone-filled gallbladder often becomes a time-consuming and difficult part of the operation. We have developed a new instrument for quick and safe extraction of the stone-filled gallbladder. The instrument, called "Bergetrokar", is a trocar cannula with a trumpet valve and cone-shaped tip which can be spread. The application of this device is simple. After using the "Bergetrokar" in about 180 cases we have not observed any perforation of the gallbladder or loss of stones. Extraction times were reduced.

  4. CT-guided thermocouple placement for hyperthermia treatment.

    PubMed

    Banerian, K G; Roberts, J L; Borrego, J C; Martinez, A

    1990-05-01

    There is a well-documented synergistic cytotoxic effect when heat is combined with ionizing radiation. An integral component of hyperthermia treatments is the placement of thermocouple probes used for thermal dosimetry. With the surge in interest in the clinical use of hyperthermia, our department is performing an increasing number of thermocouple placements under computed tomographic (CT) guidance. We describe our technique for CT-guided thermocouple placement with two different systems: a trocar introduction system and a peel-away needle introduction system. We discuss the rationale for thermocouple placement, our early experience with this technique, and some potential complications.

  5. Laparoscopic-assisted extracorporeal ovarian cystectomy: a new technique.

    PubMed

    Ikuma, Kenichino; Amin, Magdy; Yukio, Yamada; Hisato, Okuo; Yoshihiro, Ito; Shintaro, Ueda; Masako, Tanaka; Yasuki, Koyasu

    2004-01-01

    An increasing number of adnexal masses are currently managed laparoscopically, which has hampered progress regarding the different techniques of laparoscopic surgery. In this chapter, a modified application of surgical instrument was described in laparoscopic ovarian cystectomy-we named this device, Lap-Disc Mini. This new instrument has three rings, an inner flexible ring fixed to a middle ring by a rubber corset, and an additional dynamic outer ring that has a rubbery-like iris opening, which allows the application of different-sized trocars and extracorporeal ovarian cystectomy. This technique has proved to be effective and safe, especially in removing large ovarian cyst.

  6. Order Denying the Petition to Object to the Xcel Energry Cherokee Station, Adams County, Colorado Title V Operating Permit

    EPA Pesticide Factsheets

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  7. Transumbilical laparoscopically assisted appendectomy in children: the results of a single-port, single-channel procedure.

    PubMed

    Ohno, Yasuharu; Morimura, Toshiya; Hayashi, Shin-ichi

    2012-02-01

    Even for pediatric patients, the use of laparoscopic appendectomy has been widely accepted, and three trocars usually are necessary to perform a laparoscopic appendectomy. However, single-port appendectomy for children represents an attractive alternative. To reduce the number of incisions and trocars, the authors have adopted a transumbilical laparoscopically assisted single-port appendectomy (TULAA) approach. This study aimed to evaluate the results of their single-channel, single-port appendectomy. A retrospective study of TULAA was performed during 12 years with 500 children ages 2-16 years (median, 10.2 years). The TULAA approach is a single-channel surgery using a 12 mm conventional single-port. The vertical incision through the umbilicus is used for laparoscopic access. Two laparoscopic instruments, a 5 mm telescope and a 5 mm grasper, are inserted simultaneously into the single-channel. The grasper holds the base of the appendix, and the appendix is exteriorized through the umbilical incision. Thereafter, a conventional appendectomy is performed extracorporeally. The TULAA procedure was successful for 416 patients (83.2%). These successful TULAA procedures required a mean surgery time of 44.5 min. The pathologic diagnosis of the appendix was acute for 59 patients, phlegmonous for 203 patients, gangrenous for 152 patients, and not detected for two patients. Complications occurred for 47 of these patients (11.3%). Most of the complications were associated with severe intraabdominal inflammation. Two patients needed reoperation under general anesthesia. Conversion to multitrocar surgery or open appendectomy was performed for 84 of the patients (16.8%). The TULAA procedure is a preferable operation for acute appendicitis in children because it is simple and provides good cosmetic results.

  8. Transumbilical endoscopic surgery for incarcerated inguinal hernias in infants and children.

    PubMed

    Zhou, Xuewu; Peng, Lei; Sha, Yongliang; Song, Daiqiang

    2014-01-01

    To describe transumbilical laparoscopic herniorrhaphy after unsuccessful attempted manual reduction of incarcerated inguinal hernias in infants and children. In our two hospitals, two-trocar transumbilical endoscopic surgery (TUES) is the standard technique used to repair incarcerated inguinal hernias in infants and children. Seventeen patients (aged 8months to 2.5years; median, 15months; 15 boys, 2 girls) with incarcerated inguinal hernias underwent urgent laparoscopy after unsuccessful attempted manual reduction. Two 3- or 5-mm trocars were inserted into the abdomen through two intraumbilical incisions, under laparoscopic guidance. The hernia was reduced by combined external manual pressure and internal pulling with bowel forceps. After inspection of the bowel, a round needle with a 2-0 nonabsorbable suture was introduced into the peritoneal cavity through the anterior abdominal wall near the internal inguinal ring. The hernial orifice was closed with an extraperitoneal purse-string suture around the internal inguinal ring, and tied with an intraperitoneal knot. A similar procedure was performed on the contralateral side if the processus vaginalis was patent. The TUES procedure was successful in all patients. No conversions to open surgery were required. The mean operating time was 30min (range, 25-40min). All patients were discharged on the second postoperative day. No complications such as postoperative bleeding, hydrocele, or scrotal edema were observed. The mean follow-up period was 15months. No cases of testicular atrophy, hypotrophy, or hernia recurrence were reported. Our preliminary experience with using TUES for the treatment of incarcerated inguinal hernias in infants and children had satisfactory outcomes. This technique appeared to be safe, effective, and reliable, and had excellent cosmetic results. Published by Elsevier Inc.

  9. Transconjunctival drainage of serous and hemorrhagic choroidal detachment.

    PubMed

    Rezende, Flávio A; Kickinger, Mônica C; Li, Gisèle; Prado, Renata F; Regis, Luiz Gustavo T

    2012-02-01

    To describe a novel surgical technique for drainage of bullous serous and hemorrhagic choroidal detachments. A prospective, consecutive case series of 6 eyes with serous and/or hemorrhagic choroidal detachments secondary to intraocular surgery was documented to evaluate the feasibility of using the 25-gauge and 20-gauge transconjunctival trocar/cannula systems to drain choroidal detachments. Two eyes had expulsive hemorrhagic choroidal detachments and 4 eyes had serous choroidal detachments after glaucoma surgeries. A 25-gauge infusion line was placed in the anterior chamber. A 20-gauge (in eyes with hemorrhagic choroidal detachments) or a 25-gauge (in eyes with serous detachments) trocar/cannula system was inserted into the suprachoroidal space 7.0 mm from limbus. After drainage, the cannulas were removed and no sutures were placed. Pars plana vitrectomy was performed only in eyes with concomitant pathology that demanded the additional procedure. The primary outcome measure was presence of choroidal detachment at 1 week, 2 weeks, and 1 month postoperatively. Secondary outcome measures were visual acuity at 6 months and intraocular pressure at 1 week and 1, 3, and 6 months postoperatively. Drainage of hemorrhagic choroidal detachments resulted in resolution of the detachments by 1 month postoperatively. In eyes with serous detachments, resolution was achieved by 1 week postdrainage. In both groups, intraocular pressure increased to at least 10 mmHg by postoperative Week 1. The visual acuity improved in all eyes. No complications related to the transconjunctival technique were noted. Transconjunctival drainage of serous and hemorrhagic choroidal detachments seems to be a feasible and simple surgical option with minimal scleral and conjunctival damage. Pars plana vitrectomy may not be necessary when draining choroidal detachments in this manner.

  10. A new technique for repeated biopsies of the mammary gland in dairy cows allotted to Latin-square design studies

    PubMed Central

    de Lima, Luciano S.; Martineau, Eric; De Marchi, Francilaine E.; Palin, Marie-France; dos Santos, Geraldo T.; Petit, Hélène V.

    2016-01-01

    The objective of this study was to develop a technique for carrying out repeated biopsies of the mammary gland of lactating dairy cows that provides enough material to monitor enzyme activities and gene expression in mammary secretory tissue. A total of 16 Holstein cows were subjected to 4 mammary biopsies each at 3-week intervals for a total of 64 biopsies. A 0.75-cm incision was made through the skin and subcutaneous tissue of the mammary gland and a trocar and cannula were inserted using a circular motion. The trocar was withdrawn and a syringe was plugged into the base of the cannula to create a vacuum for sampling mammary tissue. To reduce bleeding, hand pressure was put on the surgery site after biopsy and skin closure and ice was applied for at least 2 h after the biopsy using a cow bra. The entire procedure took an average of 25 min. Two attempts were usually enough to obtain 800 mg of tissue. Visual examination of milk samples 10 d after the biopsy indicated no trace of blood, except in samples from 2 cows. All wounds healed without infection and subcutaneous hematomas resorbed within 7 d. There was no incidence of mastitis throughout the lactation. This technique provides a new tool for biopsy of the mammary gland repeated at short intervals with the main effect being a decrease in milk production. Although secondary complications leading to illness or death are always a risk with any procedure, this biopsy technique was carried out without complications to the health of animals and with no incidence of mastitis during the lactation. PMID:27408336

  11. A new technique for repeated biopsies of the mammary gland in dairy cows allotted to Latin-square design studies.

    PubMed

    de Lima, Luciano S; Martineau, Eric; De Marchi, Francilaine E; Palin, Marie-France; Dos Santos, Geraldo T; Petit, Hélène V

    2016-07-01

    The objective of this study was to develop a technique for carrying out repeated biopsies of the mammary gland of lactating dairy cows that provides enough material to monitor enzyme activities and gene expression in mammary secretory tissue. A total of 16 Holstein cows were subjected to 4 mammary biopsies each at 3-week intervals for a total of 64 biopsies. A 0.75-cm incision was made through the skin and subcutaneous tissue of the mammary gland and a trocar and cannula were inserted using a circular motion. The trocar was withdrawn and a syringe was plugged into the base of the cannula to create a vacuum for sampling mammary tissue. To reduce bleeding, hand pressure was put on the surgery site after biopsy and skin closure and ice was applied for at least 2 h after the biopsy using a cow bra. The entire procedure took an average of 25 min. Two attempts were usually enough to obtain 800 mg of tissue. Visual examination of milk samples 10 d after the biopsy indicated no trace of blood, except in samples from 2 cows. All wounds healed without infection and subcutaneous hematomas resorbed within 7 d. There was no incidence of mastitis throughout the lactation. This technique provides a new tool for biopsy of the mammary gland repeated at short intervals with the main effect being a decrease in milk production. Although secondary complications leading to illness or death are always a risk with any procedure, this biopsy technique was carried out without complications to the health of animals and with no incidence of mastitis during the lactation.

  12. Magnetic Surgery

    PubMed Central

    Rivas, Homero; Robles, Ignacio; Riquelme, Francisco; Vivanco, Marcelo; Jiménez, Julio; Marinkovic, Boris; Uribe, Mario

    2018-01-01

    Objective: To evaluate a new magnetic surgical system during reduced-port laparoscopic cholecystectomy in a prospective, multicenter clinical trial. Background: Laparoscopic instrumentation coupled by magnetic fields may enhance surgeon performance by allowing for shaft-less retraction and mobilization. The movements can be performed under direct visualization, generating different angles of traction and reducing the number of trocars to perform the procedure. This may reduce well-known associated complications of trocars, including incisional pain, scarring, infection, bowel, and vascular injuries, among others. Methods: A prospective, multicenter, single-arm, open-label study was performed to assess the safety and performance of a magnetic surgical system (Levita Magnetics’ Surgical System). The investigational device was used during a 3-port laparoscopic technique. The primary endpoints evaluated were safety and feasibility of the device to adequately mobilize the gallbladder to achieve effective exposure of the targeted surgical site. Patients were followed for 30 days postprocedure. Results: Between January 2014 and March 2015, 50 patients presenting with benign gallbladder disease were recruited. Forty-five women and 5 men with an average age of 39 years (18–59), average body mass index of 27 kg/m2 (20.4–34.1) and an average abdominal wall thickness of 2.6 cm (1.8–4.6). The procedures were successfully performed in all 50 patients. No device-related serious adverse events were reported. Surgeons rated as “excellent” (90%) or “sufficient” (10%) the exposure of the surgical site. Conclusions: This clinical trial shows that this new magnetic surgical system is safe and effective in reduced-port laparoscopic cholecystectomy. PMID:27759614

  13. Pedicle screw cement augmentation. A mechanical pullout study on different cement augmentation techniques.

    PubMed

    Costa, Francesco; Ortolina, Alessandro; Galbusera, Fabio; Cardia, Andrea; Sala, Giuseppe; Ronchi, Franco; Uccelli, Carlo; Grosso, Rossella; Fornari, Maurizio

    2016-02-01

    Pedicle screws with polymethyl methacrylate (PMMA) cement augmentation have been shown to significantly improve the fixation strength in a severely osteoporotic spine. However, the efficacy of screw fixation for different cement augmentation techniques remains unknown. This study aimed to determine the difference in pullout strength between different cement augmentation techniques. Uniform synthetic bones simulating severe osteoporosis were used to provide a platform for each augmentation technique. In all cases a polyaxial screw and acrylic cement (PMMA) at medium viscosity were used. Five groups were analyzed: I) only screw without PMMA (control group); II) retrograde cement pre-filling of the tapped area; III) cannulated and fenestrate screw with cement injection through perforation; IV) injection using a standard trocar of PMMA (vertebroplasty) and retrograde pre-filling of the tapped area; V) injection through a fenestrated trocar and retrograde pre-filling of the tapped area. Standard X-rays were taken in order to visualize cement distribution in each group. Pedicle screws at full insertion were then tested for axial pullout failure using a mechanical testing machine. A total of 30 screws were tested. The results of pullout analysis revealed better results of all groups with respect to the control group. In particular the statistical analysis showed a difference of Group V (p = 0.001) with respect to all other groups. These results confirm that the cement augmentation grants better results in pullout axial forces. Moreover they suggest better load resistance to axial forces when the distribution of the PMMA is along all the screw combining fenestration and pre-filling augmentation technique. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Port-Site Metastases and Chimney Effect of B-Ultrasound-Guided and Laparoscopically-Assisted Hyperthermic Intraperitoneal Perfusion Chemotherapy

    PubMed Central

    Zhang, Xiang-Liang; Gong, Yuan-Feng; Yan, Zhao-Fei; Wang, Shuai; Tang, Yun-Qiang; Cui, Shu-Zhong

    2017-01-01

    Purpose CO2 leakage along the trocar (chimney effect) has been proposed to be an important factor underlying port-site metastasis after laparoscopic surgery. This study aimed to test this hypothesis by comparing the incidence of port-site metastasis between B-ultrasound-guided and laparoscopically-assisted hyperthermic intraperitoneal perfusion chemotherapy (HIPPC). Materials and Methods Sixty-two patients with malignant ascites induced by gastrointestinal or ovarian cancer were divided into two groups to receive either B-ultrasound-guided or laparoscopically-assisted HIPPC. Clinical efficacy was assessed from the objective remission rate (ORR), the Karnofsky Performance Status (KPS) score, and overall survival. The incidence of port-site metastasis was compared between the two groups. Results Patients in the B-ultrasound (n=32) and laparoscopy (n=30) groups were comparable in terms of age, sex, primary disease type, volume of ascites, and free cancer cell (FCC)-positive ascites. After HIPPC, there were no significant differences between the B-ultrasound and laparoscopy groups in the KPS score change, ORR, and median survival time. The incidence of port-site metastasis after HIPPC was not significantly different between the B-ultrasound (3 of 32, 9.36%) and laparoscopy (3 of 30, 10%) groups, but significantly different among pancreatic, gastric, ovarian, and colorectal cancer (33.33, 15.79, 10.00, and 0.00%, p<0.001). Conclusion The chimney effect may not be the key reason for port-site metastasis after laparoscopy. Other factors may play a role, including the local microenvironment at the trocar site and the delivery of viable FCCs (from the tumor or malignant ascites) to the trauma site during laparoscopic surgery. PMID:28332353

  15. Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com; Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com

    ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioningmore » a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.« less

  16. Modified Peritoneal Dialysis Catheter Insertion: Comparison with a Conventional Method.

    PubMed

    Lee, Yong Kyu; Yang, Pil-Sung; Park, Kyoung Sook; Choi, Kyu Hun; Kim, Beom Seok

    2015-07-01

    The conventional trocar and cannula method in peritoneal dialysis (PD) catheter insertion has its limitation in clinical setting. The aim of this study was to compare a modified method for percutaneous PD catheter insertion with the conventional method, and demonstrate advantages of the modified method. Patients at a single center who had percutaneous PD catheters inserted by nephrologists from January 2006 until September 2012, using either a modified method (group M) or the conventional trocar and cannula method (group C), were retrospectively analyzed, in terms of baseline characteristics, complications experienced up to 3 months after the procedure, and the suitability of the procedure for patients. Group M included 82 subjects, while group C included 66 cases. The overall early complication rate in group M (1.2%) was significantly lower than that in group C (19.7%) (p<0.001). The catheter revision rate during timeframe for early complications was significantly lower in group M (0%) than in group C (6.1%) (p=0.024). When comparing Procedure time (1 h 3 min±16 min vs. 1 h 36 min±19 min, p<0.01), immediate post-procedural pain (2.43±1.80 vs. 3.14±2.07, p<0.05), and post-procedure days until ambulation (3.95±1.13 days vs. 6.17±1.34 days, p<0.01), group M was significantly lower than group C. There was no significant difference in total hospitalization period (14.71±7.05 days vs. 13.86±3.7 days). Our modified PD catheter insertion method shows its advantages in early complication rate, early complications revision rate, and the patients' conveniences.

  17. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement ofmore » the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.« less

  18. Mini-Laparoscopy: Instruments and Economics.

    PubMed

    Shadduck, Phillip P; Paquentin, Eduardo Moreno; Carvalho, Gustavo L; Redan, Jay A

    2015-11-01

    Mini-laparoscopy (Mini) was pioneered more than 20 years ago, initially with instruments borrowed from other specialties and subsequently with tools designed specifically for Mini. Early adoption of Mini was inhibited though by the limitations of these first-generation instruments, especially functionality and durability. Newer generation Mini instruments have recently become available with improved effector tips, a choice of shaft diameters and lengths, better shaft insulation and electrosurgery capability, improved shaft strength and rotation, more ergonomic handles, low-friction trocar options, and improved instrument durability. Improvements are also occurring in imaging and advanced energy for Mini. The current status of mini-laparoscopy instruments and economics are presented.

  19. Design by Analogy: Achieving More Patentable Ideas from One Creative Design

    NASA Astrophysics Data System (ADS)

    Jia, Li-Zhen; Wu, Chun-Long; Zhu, Xue-Hong; Tan, Run-Hua

    2018-12-01

    A patent is a kind of technical document to protect intellectual property for individuals or enterprises. Patentable idea generation is a crucial step for patent application and analogy is confirmed to be an effective technique to inspire creative ideas. Analogy-based design usually starts from representation of an analogy source and is followed by the retrieval of appropriate analogs, mapping of design knowledge and adaptation of target solution. To diffuse one core idea into other new contexts and achieve more patentable ideas, this paper mainly centered on the first two stages of analogy-based design and proposed a patentable ideation framework. The analogical information of the source system, including source design problems and solution, was mined comprehensively through International Patent Classification analysis and represented in the form of function, behavior and structure. Three heuristics were suggested for searching the set of candidate target systems with a similar design problem, where the source design could be transferred. To systematize the process of source representation, analogs retrieval, idea transfer, and solution generation, an ideation model was put forward. Finally, the bladeless fan was selected as a source design to illustrate the application of this work. The design output shows that the representation and heuristics are beneficial, and this systematic ideation method can help the engineer or designer enhance creativity and discover more patentable opportunities.

  20. Analysis of Coupled Seals, Secondary and Powerstream Flow Fields in Aircraft and Aerospace Turbomachines

    NASA Technical Reports Server (NTRS)

    Athavale, M. M.; Ho, Y. H.; Prezekwas, A. J.

    2005-01-01

    Higher power, high efficiency gas turbine engines require optimization of the seals and secondary flow systems as well as their impact on the powerstream. This work focuses on two aspects: 1. To apply the present day CFD tools (SCISEAL) to different real-life secondary flow applications from different original equipment manufacturers (OEM s) to provide feedback data and 2. Develop a computational methodology for coupled time-accurate simulation of the powerstream and secondary flow with emphasis on the interaction between the disk-cavity and rim seals flows with the powerstream (SCISEAL-MS-TURBO). One OEM simulation was of the Allison Engine Company T-56 turbine drum cavities including conjugate heat transfer with good agreement with data and provided design feedback information. Another was the GE aspirating seal where the 3-D CFD simulations played a major role in analysis and modification of that seal configuration. The second major objective, development of a coupled flow simulation capability was achieved by using two codes MS-TURBO for the powerstream and SCISEAL for the secondary flows with an interface coupling algorithm. The coupled code was tested against data from three differed configurations: 1. bladeless-rotor-stator-cavity turbine test rig, 2. UTRC high pressure turbine test rig, and, 3. the NASA Low-Speed-Air Compressor rig (LSAC) with results and limitations discussed herein.

  1. Acquisition and diversification of tendrilled leaves in Bignonieae (Bignoniaceae) involved changes in expression patterns of SHOOTMERISTEMLESS (STM), LEAFY/FLORICAULA (LFY/FLO), and PHANTASTICA (PHAN).

    PubMed

    Sousa-Baena, Mariane Silveira; Lohmann, Lúcia G; Rossi, Magdalena; Sinha, Neelima R

    2014-02-01

    Leaves have undergone structural modifications over evolutionary time, and presently exist in many forms. For instance, in Fabaceae and Bignoniaceae, leaf parts can be modified into tendrils. Currently, no data are available on genic control of tendrilled leaf development outside Fabaceae. Here, we conducted a detailed study of three representatives of Bignonieae: Amphilophium buccinatorium, Dolichandra unguis-cati, and Bignonia callistegioides, bearing multifid, trifid, and simple-tendrilled leaves, respectively. We investigated the structure of their petioles, petiolules, leaflets, and tendrils through histological analyses. Additionally, the expression of SHOOTMERISTEMLESS (STM), PHANTASTICA (PHAN), and LEAFY/FLORICAULA (LFY/FLO) during leaf development was analyzed by in situ hybridizations. Tendrils share some anatomical similarities with leaflets, but not with other leaf parts. Transcripts of both STM and LFY/FLO were detected in leaf primordia, associated with regions from which leaflets and tendril branches originate. PHAN expression was found to be polarized in branched tendrils, but not in simple tendrils. In Bignonieae, tendrils are modified leaflets that, as a result of premature completion of development, become bladeless organs. Bignonieae leaves develop differently from those of peas, as both LFY/FLO and STM are expressed in developing leaves of Bignonieae. Moreover, PHAN is probably involved in tendril diversification in Bignonieae, as it has distinct expression patterns in different leaf types. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.

  2. Order Denying the Petition to Object to the Xcel Energy Valmont Power Station, Boulder County, Colorado Title V Operating Permit

    EPA Pesticide Factsheets

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  3. Order Granting and Denying in Part the Petition for Objection to the Xcel Energy, Hayden Station Operating Permit, Hayden Colorado

    EPA Pesticide Factsheets

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  4. Order Responding to Petition to Object to Xcel Energy Pawnee Coal Fired Power Station, Brush, Colorado Title V Operating Permit

    EPA Pesticide Factsheets

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  5. Endoscope-Assisted Transoral Fixation of Mandibular Condyle Fractures: Submandibular Versus Transoral Endoscopic Approach.

    PubMed

    Hwang, Na-Hyun; Lee, Yoon-Hwan; You, Hi-Jin; Yoon, Eul-Sik; Kim, Deok-Woo

    2016-07-01

    In recent years, endoscope-assisted transoral approach for condylar fracture treatment has attracted much attention. However, the surgical approach is technically challenging: the procedure requires specialized instruments and the surgeons experience a steep learning curve. During the transoral endoscopic (TE) approach several instruments are positioned through a narrow oral incision making endoscope maneuvering very difficult. For this reason, the authors changed the entry port of the endoscope from transoral to submandibular area through a small stab incision. The aim of this study is to assess the advantage of using the submandibular endoscopic intraoral approach (SEI).The SEI approach requires intraoral incision for fracture reduction and fixation, and 4 mm size submandibular stab incision for endoscope and traction wires. Fifteen patients with condyle neck and subcondyle fractures were operated under the submandibular approach and 15 patients with the same diagnosis were operated under the standard TE approach.The SEI approach allowed clear visualization of the posterior margin of the ramus and condyle, and the visual axis was parallel to the condyle ramus unit. The TE approach clearly shows the anterior margin of the condyle and the sigmoid notch. The surgical time of the SEI group was 128 minutes and the TE group was 120 minutes (P >0.05). All patients in the TE endoscope group were fixated with the trocar system, but only 2 lower neck fracture patients in the SEI group required a trocar. The other 13 subcondyle fractures were fixated with an angulated screw driver (P <0.05). There were no differences in complication and surgical outcomes.The submandibular endoscopic approach has an advantage of having more space with good visualization, and facilitated the use of an angulated screw driver.

  6. Vesicoscopic Treatment of Symptomatic Congenital Bladder Diverticula in Children: A 7-Year Experience.

    PubMed

    Marte, Antonio; Cavaiuolo, Silvia; Esposito, Maria; Pintozzi, Lucia

    2016-06-01

    Introduction The objective of this study was to report on the use of vesicoscopy in the treatment of symptomatic congenital bladder diverticula (CBD) in children. Material and Methods In this study, 16 males, aged 4 to 12 years (median age, 6.25 years), were treated for symptomatic CBD; 3 patients presented double diverticulum and 13 presented single diverticulum. The presenting symptoms were recurrent urinary tract infection, hematuria, lower abdominal pain, and voiding dysfunctions as urgency, frequency alone, or in association. A first midline 5-mm trocar was introduced for a 0-degree telescope at the dome of the bladder, and two left and right 3- or 5-mm trocars were inserted through the anterolateral wall. The bladder was then insufflated with carbon dioxide to 10 to 12 mm Hg pressure. The diverticula were inverted into the bladder and the mucosa around the neck was circumcised by using scissors and hook. The defect was sutured and the bladder was drained. Vesicoureteral reflux (VUR) of third grade or higher was treated endoscopically. Results Mean operative time was 90 minutes for procedures. At 6-month follow-up, ultrasound and voiding cystourethrogram (VCUG) showed the disappearance of the diverticulum in 15 out of the 16 patients. The patient, with huge double diverticulum and fourth grade right VUR, presented recurrence of a small left diverticulum. Patients with voiding disorders presented a gradual improvement of their urgency. VUR disappeared at VCUG in all patients. Conclusion Vesicoscopic diverticulectomy resulted a safe and effective procedure and can be considered a valid alternative to the open or laparoscopic procedures. In our opinion, routine use of vesicoscopy could become the gold standard for the treatment of CBD in children. Georg Thieme Verlag KG Stuttgart · New York.

  7. Comparison of two specimen retrieval techniques in laparoscopic sleeve gastrectomy: what is the role of endobag?

    PubMed

    Shoar, Saeed; Aboutaleb, Shereen; Karem, Mohsen; Bashah, Moataz M; AlKuwari, Mohamed; Sargsyan, Davit; Saber, Alan A

    2017-12-01

    Laparoscopic sleeve gastrectomy (LSG) has become a popular stand-alone treatment for morbid obesity. However, removal of the gastric specimen could be a challenging step due to its large size relative to the width of the trocar site. We aimed to compare a simplified retrieval technique for extraction of the gastric specimen without an endobag with conventionally performed specimen retrieval using an endobag. A case-control study was conducted recruiting patients undergoing LSG. Patient's demographics, preoperative characteristics, intra-operative, and postoperative variables were compared between the two groups according to the technique of gastric specimen removal. A total of 193 patients (60.6% female) were enrolled into case (n = 100) and control groups (n = 93). Mean ± SD age and BMI of patients were 35.64 ± 11.84 years and 47.28 ± 8.22 Kg/m 2 , respectively with no significant difference between groups. Median (25th, 75th inter-quartile), extraction time was significantly reduced in the non-endobag group compared to the endobag group (3.5 [2.5-4.5] min vs. 6.5 [3.4-8.2] min, p = 0.03).Patients of both groups had similar intra-operative and trocar site complications (hernia and wound infection) (3% for endobag group and 3.3 % for non-endobag group). The median (25-75% [IQR]) LOS was also comparable between endobag and non-endobag patients (3[2-3] vs. 3[2-4] days, p = 0.84). No difference was observed between the two groups for weight loss and comorbidity resolution. Non-endobag technique for gastric specimen retrieval is safe and feasible with substantial saving in operative time and comparable intra-operative and postoperative outcomes to the conventional retrieval technique.

  8. SUPRAPUBIC LAPAROSCOPIC CHOLECYSTECTOMY: TECHNIQUE AND PRELIMINARY RESULTS

    PubMed Central

    SALES, Leonardo Adolpho S.; PINTO, João Odilo G.; QUEIROZ, Carlos Eduardo F.; CASTRO, Marcelo; DOURADO, Paulo Henrique F.; PINHEIRO, Fernando Antonio S.

    2014-01-01

    Background The minimally invasive abdominal surgery has evolved to reduce portals, culminating with a single incision and natural orifice operation. However, these methods are still expensive, difficult to implement and with questionable aesthetic results. Aim To present the standardization and preliminary results of a technique for performing laparoscopic suprapubic access by the principle which was called the Supra Pubic Endoscopic Surgery for cholecystectomy. Method The average body mass index of patients, the mean operative time, clinical data of the postoperative complications and quality of life were prospectively studied. The operation incisions consisted of: A) umbilical for instrumental dissection and clipping; B) in the right groin for handling and gallbladder gripping; C) suprapubic for the camera. With the patient in reverse Trendelenburg and left lateral decubitus, the operation flew by the camera trocar in C, proceeding with dissection and isolation of the biliary pedicle, identification of cystic duct and artery, with usual instrumentation. Transcystic intraoperative cholangiography was performed in all cases in which there were indications. The procedure was completed with clipping and sectioning of the cystic duct and artery, retrograde resection of the gallbladder and extracting it by the umbilical trocar incision under direct vision. Results Thirty patients undergone this surgical procedure between March and June 2012 and were evaluated. The mean age was 40.7 years and the indications were typical biliary colic in 18 cases (60 %), cholecystitis in five cases (16.6 %), biliary pancreatitis in one case (3.3%); polyp in three cases (10%) and obstructive jaundice at three cases (10%). The average body mass index was 27.8 (23.1-35.1) and surgical time ranged between 24 and 70 minutes. Conclusion The technique proved to be feasible and safe , with no significant complications, and satisfactory cosmetic results. PMID:24676293

  9. New advantageous tool in single incision laparoscopic cholecystectomy: the needle grasper.

    PubMed

    Donmez, Turgut; Uzman, Sinan; Ferahman, Sina; Demiryas, Suleyman; Hatipoglu, Engin; Uludag, Server Sezgin; Yildirim, Dogan

    2016-01-01

    During single-incision laparoscopic cholecystectomy (SILC), the gallbladder is suspended with stitches, resulting in perforation risk and difficulty in exploration. We used the needle grasper in SILC to hang and manipulate the gallbladder. Sixty-five patients (43 female, 22 male) who underwent SILC between December 2013 and December 2014 were analyzed retrospectively for patient demographics, duration of operation, laparotomy or conventional laparoscopy necessity, drain use, complications, and hospital stay periods. To place the SILC port (Covidien, Inc.), the needle grasper was inserted at the right upper abdominal quadrant without an incision to hang and manipulate the gall-bladder. The mean age was 47.9 ±13.068 years; the mean body mass index (BMI) was 26.94 ±3.913 kg/m 2 . ASA scores were 1, 2, and 3. Two patients with high BMI with additional trocar use were excluded. The operations were completed without any additional trocar in 59 patients. The mean operation time was 89 ±22.41 min. Eighteen patients required a drain; all were discharged after drain removal. One patient needed re-hospitalization and percutaneous drainage and was discharged on the 9 th day. Fifty-three patients were discharged on the 1 st post-operative day. Eleven patients with drains were discharged on the 2 nd day, and 1 was discharged on the 7 th day. The mean hospital stay period was 1.26 ±0.815 days. The main difficulty of SILC is to manipulate hand tools because the triangulation principle of laparoscopy use is not possible in SILC. Inserting a needle grasper into the abdominal cavity at the right subcostal area to manipulate the gallbladder helps and does not leave a visible scar.

  10. Retroperitoneal access for robotic renal surgery.

    PubMed

    Anderson, Barrett G; Wright, Alec J; Potretzke, Aaron M; Figenshau, R Sherburne

    2018-01-01

    Retroperitoneal access for robotic renal surgery is an effective alternative to the commonly used transperitoneal approach. We describe our contemporary experience and technique for attaining retroperitoneal access. We outline our institutional approach to retroperitoneal access for the instruction of urologists at the beginning of the learning curve. The patient is placed in the lateral decubitus position. The first incision is made just inferior to the tip of the twelfth rib as described by Hsu, et al. After the lumbodorsal fascia is traversed, the retroperitoneal space is dilated with a round 10 millimeter AutoSutureTM (Covidien, Mansfield, MA) balloon access device. The following trocars are used: A 130 millimeter KiiR balloon trocar (Applied Medical, Rancho Santa Margarita, CA), three robotic, and one assistant. Key landmarks for the access and dissection are detailed. 177 patients underwent a retroperitoneal robotic procedure from 2007 to 2015. Procedures performed include 158 partial nephrectomies, 16 pyeloplasties, and three radical nephrectomies. The robotic fourth arm was utilized in all cases. When compared with the transperitoneal approach, the retroperitoneal approach was associated with shorter operative times and decreased length of stay (1). Selection bias and surgeon preference accounted for the higher proportion of patients who underwent partial nephrectomy off-camp via the retroperitoneal approach. Retroperitoneal robotic surgery may confer several advantages. In patients with previous abdominal surgery or intra-abdominal conditions, the retroperitoneum can be safely accessed while avoiding intraperitoneal injuries. The retroperitoneum also provides a confined space that may minimize the sequelae of potential complications including urine leak. Moreover, at our institution, retroperitoneal robotic surgery is associated with shorter operative times and a decreased length of stay when compared with the transperitoneal approach (2). In selected

  11. Findings of universal cystoscopy at incontinence surgery and their sequelae

    PubMed Central

    Zyczynski, Halina M.; Sirls, Larry T.; Greer, W. Jerod; Rahn, David D.; Casiano, Elizabeth; Norton, Peggy; Kim, Hae-Young; Brubaker, Linda

    2014-01-01

    OBJECTIVE The purpose of this study was to report the frequency of abnormal cystoscopy at incontinence surgery and to identify risk factors and sequelae of injury. STUDY DESIGN Findings of cystoscopy were collected prospectively in 3 multicenter surgical trials. Clinical, demographic, and procedure characteristics and surgeon experience were analyzed for association with iatrogenic injury and noninjury abnormalities. Impact of abnormalities on continence outcomes and adverse events during 12 months after the procedure were assessed. RESULTS Abnormal findings in the bladder or urethra were identified in 95 of 1830 women (5.2%). Most injuries (75.8%) were iatrogenic. Lower urinary tract (LUT) injury was most common at retropubic urethropexy and retropubic midurethral sling procedures (MUS; 6.4% each), followed by autologous pubovaginal sling procedures (1.7%) and transobturator MUS (0.4%). Increasing age (56.9 vs 51.9 years; P = .04), vaginal deliveries (3.2 vs 2.6; P = .04), and blood loss (393 vs 218 mL; P=.01) were associated with LUT injury during retropubic urethropexy; however, only age (62.9 vs 51.4 years; P = .02) and smoking history (P = .04) were associated for pubovaginal sling procedures. No factors correlated with increased risk of injury at retropubic and transobturator MUS. Notably, previous incontinence surgery, concomitant procedures, anesthesia type, and trainee participation did not increase LUT injury frequency. Although discharge with an indwelling catheter was more common after trocar perforation compared with the noninjury group (55.6% vs 18.5%; P < .001), they did not differ in overall success, voiding dysfunction, recurrent urinary tract infections, or urge urinary incontinence. CONCLUSION Universal cystoscopy at incontinence surgery detects abnormalities in 1 in 20 women. Urinary trocar perforations that are addressed intraoperatively have no long-term adverse sequelae. PMID:24380742

  12. Securing the appendiceal stump with the Gea extracorporeal sliding knot during laparoscopic appendectomy is safe and economical.

    PubMed

    Arcovedo, R; Barrera, H; Reyes, H S

    2007-10-01

    Laparoscopic appendectomy (LA) has become very popular. One criticism of this approach is the high cost of the disposable equipment such as the linear stapler. An alternative would be suture ligation of the appendiceal base. To prove the safety of the Gea extracorporeal sliding knot (GESK) for closure of the stump after LA, a retrospective study was conducted. For this study, 63 LA procedures performed by one surgeon using the Gea knot (group A) were reviewed and compared with 63 LA procedures performed by two other surgeons (group B) using the linear stapler. The GESK is created with 0-prolene in the manner already described. The main variable was the presence or absence of blowout, leak, or fistula from the appendiceal stump. The secondary variables were abdominal abscess, wound infection, and need for readmission or reoperation. The results were analyzed using the appropriate statistical methods. Both groups were similar in terms of age, gender, and pathologic diagnosis. No patient in group A or B experienced a colonic fistula, stump blowout, or leak. In group A, one patient experienced interloop abscesses. There were two wound infections. In group B, one patient experienced a wound infection, and another patient had a wound dehiscence of the umbilical port, which required reoperation. No statistical differences were noted between the two groups. There are surgeons who routinely use sutures to secure the stump of the appendectomy. This study aimed to demonstrate that the GESK is as secure as the stapler for closure of the appendiceal stump. The GESK could be passed through a 5-mm trocar, potentially avoiding complications of a larger trocar site. The GESK seems to be an economic and safe alternative to the stapler.

  13. Modified Peritoneal Dialysis Catheter Insertion: Comparison with a Conventional Method

    PubMed Central

    Lee, Yong Kyu; Yang, Pil-Sung; Park, Kyoung Sook; Choi, Kyu Hun

    2015-01-01

    Purpose The conventional trocar and cannula method in peritoneal dialysis (PD) catheter insertion has its limitation in clinical setting. The aim of this study was to compare a modified method for percutaneous PD catheter insertion with the conventional method, and demonstrate advantages of the modified method. Materials and Methods Patients at a single center who had percutaneous PD catheters inserted by nephrologists from January 2006 until September 2012, using either a modified method (group M) or the conventional trocar and cannula method (group C), were retrospectively analyzed, in terms of baseline characteristics, complications experienced up to 3 months after the procedure, and the suitability of the procedure for patients. Results Group M included 82 subjects, while group C included 66 cases. The overall early complication rate in group M (1.2%) was significantly lower than that in group C (19.7%) (p<0.001). The catheter revision rate during timeframe for early complications was significantly lower in group M (0%) than in group C (6.1%) (p=0.024). When comparing Procedure time (1 h 3 min±16 min vs. 1 h 36 min±19 min, p<0.01), immediate post-procedural pain (2.43±1.80 vs. 3.14±2.07, p<0.05), and post-procedure days until ambulation (3.95±1.13 days vs. 6.17±1.34 days, p<0.01), group M was significantly lower than group C. There was no significant difference in total hospitalization period (14.71±7.05 days vs. 13.86±3.7 days). Conclusion Our modified PD catheter insertion method shows its advantages in early complication rate, early complications revision rate, and the patients' conveniences. PMID:26069120

  14. Active electrode monitoring. How to prevent unintentional thermal injury associated with monopolar electrosurgery at laparoscopy.

    PubMed

    Vancaillie, T G

    1998-08-01

    In recent years, the use of minimally invasive surgery (MIS) has expanded to a wide variety of surgical specialties. The increased popularity of the procedure, however, has been accompanied by its share of complications, including trocar lacerations and inadvertent thermal injuries to nontargeted tissues during monopolar electrosurgery. A survey on electrosurgical thermal injuries and three case studies are presented. The new technology of active electrode monitoring (AEM) is described. AEM eliminates stray currents generated by insulation failure and capacitive coupling. To reduce the incidence of injury by monopolar electrosurgery at laparoscopy, there is a need for advanced technology, such as AEM. In addition, laparoscopic surgeons should be encouraged to study the basic concepts of the biophysics of electrosurgery.

  15. Laparoscopic Single Site Adrenalectomy Using a Conventional Laparoscope and Instrumentation

    PubMed Central

    Colon, Modesto J; LeMasters, Patrick; Newell, Phillipa; Divino, Celia; Weber, Kaare J.

    2011-01-01

    Background and Objectives: We present a case of Laparoendoscopic Single Site Surgery (LESS) left adrenalectomy performed with a conventional laparoscope and instruments. Methods: A 45-year-old male was diagnosed with hyperaldosteronism. Computed tomography detected a left adrenal nodule. Bilateral adrenal vein sampling was consistent with a left-sided source for hyperaldosteronism. Results: Total operative time for LESS left adrenalectomy was 120 minutes. The surgery was performed with conventional instruments, a standard 5-mm laparoscope, and a SILS port, with no additional incisions or trocars needed. No complications occurred, and the patient reported an uneventful recovery. Conclusions: LESS adrenalectomy is a feasible procedure. Although articulating instruments and laparoscopes may offer advantages, LESS adrenalectomy can be done without these. PMID:21902983

  16. Vitrectomy-assisted phacoemulsification for lenticular coloboma.

    PubMed

    Agarwal, Ashvin; Narang, Priya; Agarwal, Amar

    2017-02-01

    We describe a technique to prevent continuous vitreous hydration during phacoemulsification in eyes with lenticular coloboma. The hydration results from communication between the anterior and posterior chambers from the edges of the colobomatous defect. To avoid this, a valved trocar is placed at the pars plana site around the area of the lenticular defect, which allows a limited dry vitrectomy during phacoemulsification. Intermittent vitrectomy with a moderate cutting rate and low vacuum parameters accompanied by temporary halting of the phacoemulsification procedure prevents vitreous herniation into the anterior chamber and limits the extension of zonular compromise, facilitating safe phacoemulsification with appropriate capsule expansion and fixation devices and implantation of an intraocular lens. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. TECHNICAL ASPECTS OF LAPAROSCOPIC SLEEVE GASTRECTOMY

    PubMed Central

    RAMOS, Almino Cardoso; BASTOS, Eduardo Lemos de Souza; RAMOS, Manoela Galvão; BERTIN, Nestor Tadashi Suguitani; GALVÃO, Thales Delmondes; de LUCENA, Raphael Torres Figueiredo; CAMPOS, Josemberg Marins

    2015-01-01

    Background : The vertical gastrectomy indications for surgical treatment of morbid obesity have increased worldwide. Despite this increase, many aspects of surgical technique still remains in controversy. Aim : To contribute presenting surgical details in order to better realize the vertical gastrectomy technique in bariatric surgery. Methods : Technical systematization, patient preparation, positioning of the trocars, operative technique and postoperative care are presented in details. Results : During 12 months were enrolled 120 patients undergoing GV according to the technique described herein. The results are published in another ABCD article (ABCD 2015;28(Supl.1):61-64) in this same volume and number. Conclusion : The surgical technique proposed here presented itself viable and facilitating the surgeon's work on difficult points of the vertical gastrectomy. PMID:26537278

  18. Totally laparoscopic caudate lobe resection: technical aspects and literature review.

    PubMed

    Gringeri, Enrico; Boetto, Riccardo; Bassi, Domenico; D'Amico, Francesco E; Polacco, Marina; Romano, Maurizio; Barbieri, Stefania; Feltracco, Paolo; Spampinato, Marcello; Zanus, Giacomo; Cillo, Umberto

    2014-12-01

    The particular anatomic location of the hepatic caudate lobe between the hilar plate and inferior vena cava means that it is still considered unsuitable for laparoscopic measures and a difficult site even for conventional surgery. Here we describe the first case to be reported in the literature of caudate lobe resection for a single metastasis from breast adenocarcinoma that was completed using an exclusively laparoscopic procedure and a simplified scheme involving the placement of 4 trocars, without any need for conversion or the Pringle maneuver. The patient was 31 years old with a history of radical right mastectomy and chemotherapy. The patient's postoperative course was uneventful and she was discharged 4 days after the surgery. Twelve months on, she is currently alive and disease free.

  19. Incisional hernia prevention and use of mesh. A narrative review.

    PubMed

    Hernández-Granados, Pilar; López-Cano, Manuel; Morales-Conde, Salvador; Muysoms, Filip; García-Alamino, Josep; Pereira-Rodríguez, José Antonio

    2018-02-01

    Incisional hernias are a very common problem, with an estimated incidence around 15-20% of all laparotomies. Evisceration is another important problem, with a lower rate (2.5-3%) but severe consequences for patients. Prevention of both complications is an essential objective of correct patient treatment due to the improved quality of life and cost savings. This narrative review intends to provide an update on incisional hernia and evisceration prevention. We analyze the current criteria for proper abdominal wall closure and the possibility to add prosthetic reinforcement in certain cases requiring it. Parastomal, trocar-site hernias and hernias developed after stoma closure are included in this review. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. The impact of surgeon choice on the cost of performing laparoscopic appendectomy.

    PubMed

    Chu, Thomas; Chandhoke, Ryan A; Smith, Paul C; Schwaitzberg, Steven D

    2011-04-01

    While laparoscopic appendectomy (LA) can be performed using a myriad of techniques, the cost of each method varies. The purpose of this study is to analyze the effects of surgeon choice of technique on the cost of key steps in LA. Surgeon operative notes, hospital invoice lists, and surgeon instrumentation preference sheets were obtained for all LA cases in 2008 at Cambridge Health Alliance (CHA). Only cases (N = 89) performed by fulltime staff general surgeons (N = 8) were analyzed. Disposable costs were calculated for the following components of LA: port access, mesoappendix division, and management of the appendiceal stump. The actual cost of each disposable was determined based on the hospital's materials management database. Actual hospital reimbursements for LA in 2008 were obtained for all payers and compared with the disposable cost per case. Disposable cost per case for the three portions analyzed for 126 theoretical models were calculated and found to range from US $81 to US $873. The surgeon with the most cost-effective preferred method (US $299) utilized one multi-use endoscopic clip applier for mesoappendix division, two commercially available pretied loops for management of the appendiceal stump, and three 5-mm trocars as their preferred technique. The surgeon with the least cost-effective preferred method (US $552) utilized two staple firings for mesoappendix division, one staple firing for management of the appendiceal stump, and 12/5/10-mm trocars for access. The two main payers for LA patients were Medicaid and Health Safety Net, whose total hospital reimbursements ranged from US $264 to US $504 and from US $0 to US $545 per case, respectively, for patients discharged on day 1. Disposable costs frequently exceeded hospital reimbursements. Currently, there is no scientific literature that clearly illustrates a superior surgical method for performing these portions of LA in routine cases. This study suggests that surgeons should review the cost

  1. Minilaparoscopy vs Standard Laparoscopy for Sentinel Node Dissection: A Pilot Study.

    PubMed

    Uccella, Stefano; Buda, Alessandro; Morosi, Chiara; Di Martino, Giampaolo; Delle Marchette, Martina; Reato, Claudio; Casarin, Jvan; Ghezzi, Fabio

    To compare 3-mm minilaparoscopy and standard 5-mm laparoscopy for sentinel lymph node (SLN) detection in apparent early-stage endometrial cancer (EC). Retrospective study (Canadian Task Force classification II-2). Two academic research centers. Consecutive women with apparent early-stage EC who underwent surgical staging with SLN detection between November 2015 and April 2016. The surgical approach was a total laparoscopic extrafascial hysterectomy plus bilateral salpingo-oophorectomy and SLN detection. Systematic lymphadenectomy was performed in selected cases. In all patients, SLN detection was performed with cervical injection of indocyanine green and the use of an optical camera with a near-infrared high-intensity light source for detection of fluorescence imaging. All patients who underwent a minilaparoscopic approach (using one 5-mm scope and three 3-mm ancillary trocars) have been enrolled at the University of Insubria, whereas at the San Gerardo Hospital, standard laparoscopy was performed with one 10-mm scope and three 5-mm ancillary trocars. A total of 38 patients were enrolled, including 15 (39.5%) in the 3-mm group and 23 (60.5%) in the 5-mm group. No between-group differences were found in terms of demographic and tumor characteristics. Bilateral SLNs were detected in 73.3% of the patients in the 3-mm group and in 73.9% in the 5-mm group. Operative time, blood loss, hemoglobin drop, hospital stay, and the incidence and severity of complications were similar in the 2 groups. One patient (4.3%) in the standard 5-mm group had a positive SLN result (a micrometastasis in the left external iliac SLN). No positive SLNs were detected in the 3-mm group. Minilaparoscopic SLN biopsy appears to be a promising and feasible technique for EC staging. Further research is warranted to investigate the possible benefits of 3-mm instruments in this specific setting. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights

  2. Hepatic and skin metastases after laparoscopic radical prostatectomy for prostate cancer.

    PubMed

    Coman, Ioan; Crişan, Nicolae; Petrut, Bogdan; Bungărdean, Cătălina; Cristea, Tudor; Crişan, Dana

    2007-09-01

    Between 2004 and 2006, 50 radical prostatectomies were performed in our department, 46 of them through a laparoscopic approach addressed to early stage cancer (T1a,b,c and T2a,b,c N0 M0). We present the case of a 63 year old patient, who was initially diagnosed with prostate cancer in T1bN0M0 stage, Gleason score 8 and later presented atypical hepatic and trocar site metastases. This particular evolution of the case can be explained by the high value of the Gleason score and by the extension into microvessels observed on the sample prelevated by prostatectomy. The rarity of this atypical metastases and its association, the diagnostic and therapy problems are the reasons for the detailed presentation of this case.

  3. Bleeding complication with the TVT-Exact procedure: a report of two cases.

    PubMed

    Masata, Jaromir; Svabik, Kamil; Martan, Alois

    2015-02-01

    Midurethral tension-free vaginal tapes (TVT), placed through the retropubic space or through the obturator foramina, are widely used for the surgical treatment of female stress urinary incontinence. Some complications are associated with retropubic tapes owing to the passage of the tape through the space of Retzius. One of the most frequent complications is bleeding, and if injury to major vessels is involved, this may be life-threatening. In 2010, the Gynecare TVT-Exact® Continence System was introduced onto the market, with a rigid trocar shaft measuring 3.0 mm in diameter. We have no clinical data regarding the complication rate, especially concerning bleeding, connected with this device; all data are related to the original size of the TVT inserter. The cases presented demonstrate that bleeding complications can occur with the TVT-Exact procedure.

  4. Unexpected metastatic lobular carcinoma of the breast with intraabdominal spread and subsequent port-site metastasis after diagnostic laparoscopy for exclusion of ovarian cancer.

    PubMed

    Mylonas, Ioannis; Janni, Wolfgang; Friese, Klaus; Gerber, Bernd

    2004-11-01

    Although lobular carcinomas metastasize primarily to lymph nodes, bone, lung and liver, they can also spread to the gastrointestinal tract, peritoneum and gynecologic organs. We report a case of intraperitoneal carcinomatosis of a lobular breast carcinoma that metastasized primarily to the peritoneum, with a subsequent abdominal wall invasion at the trocar site following laparoscopic surgery for the exclusion of an ovarian carcinoma. Port-site metastases (PSM) have occurred after laparoscopic surgery for endometrial, fallopian tube, ovarian, and cervical cancers. This is the first report of PSM of a lobular breast carcinoma primarily metastasized to the abdominal cavity. Every surgeon should be aware of the metastatic pattern of breast cancer, especially in relation to its histological subtypes. This case report emphasizes that PSM can occur in various kinds of gynecologic tumors, including breast cancer.

  5. Three-port laparoscopic cholecystectomy by harmonic dissection without cystic duct and artery clipping.

    PubMed

    Tebala, Giovanni D

    2006-05-01

    The technique of laparoscopic cholecystectomy (LC) still has areas of refinements. To decrease the number of ports, a cannula may be replaced by a percutaneous suture suspension of the gallbladder. The risk of tissue injury caused by repeat blind extraction and insertion of various instruments in and out of the abdomen may be decreased by the use of the multipurpose harmonic dissector. One hundred consecutive patients with symptomatic cholelithiasis underwent 3-port LC entirely performed by harmonic dissector without cystic duct and artery clipping. In 8 cases, a fourth trocar was necessary. In 2 cases, the cystic duct was clipped after an unsafe ultrasound sealing. In 1 case, continuous bleeding from the liver required the use of diathermy. No common bile duct injury was registered. The 3-port harmonic LC is a feasible, effective, and safe technique.

  6. Gallbladder carcinoma late metastases and incisional hernia at umbilical port site after laparoscopic cholecystectomy.

    PubMed

    Ciulla, A; Romeo, G; Genova, G; Tomasello, G; Agnello, G; Cstronovo, Gaetano

    2006-05-01

    A potentially serious complication of laparoscopic cholecystectomy is the inadvertent dissemination of unsuspected gallbladder carcinoma. There are increasing reports of seeding of tumor at the trocar sites following laparoscopic cholecystectomy in patients with unexpected or inapparent gallbladder carcinoma. Although the mechanism of the abdominal wall recurrence is still unclear, laparoscopic handling of the tumor, perforation of the gallbladder, and extraction of the specimen without an endobag may be risk factors for the spreading of malignant cells. The Authors report the case of late development of umbilical metastasis after laparoscopic cholecystectomy; the presence of an incisional hernia and the finding of a stone in subcutaneous tissue demonstrate the diffusion of tumor cells into subcutaneous tissue during the extraction of gallbladder. The patient underwent an excision of the metastases. She is disease free two years after surgical treatment.

  7. Laparoscopic subtotal colectomy with transrectal extraction of the colon and ileorectal anastomosis.

    PubMed

    Awad, Ziad T

    2012-03-01

    Despite the growing acceptance of laparoscopic colon surgery, an abdominal incision is needed to remove the specimen and perform an anastomosis. Five trocars (one 12 mm and four 5 mm) were used. The video describes the technique of performing laparoscopic subtotal colectomy, laparoscopic cholecystectomy, transrectal removal of the gallbladder and the entire colon, and intracorporeal stapled ileorectal anastomosis in a 27-year-old female with colonic inertia and biliary dyskinesia. There were no intraoperative complications. The operating time was 180 min. Blood loss was 10 cc. The patient was discharged home on postoperative day 4. Laparoscopic subtotal colectomy with transrectal removal of the colon is a safe and effective procedure that can be added to the armamentarium of surgeons performing laparoscopic colon surgery. This technique may provide both an attractive way to reduce abdominal wall morbidity and a bridge to NOTES colon surgery.

  8. [How to do - the chest tube drainage].

    PubMed

    Klopp, Michael; Hoffmann, Hans; Dienemann, Hendrik

    2015-03-01

    A chest tube is used to drain the contents of the pleural space to reconstitute the physiologic pressures within the pleural space and to allow the lungs to fully expand. Indications for chest tube placement include pneumothorax, hemothorax, pleural effusion, pleural empyema, and major thoracic surgery. The most appropriate site for chest tube placement is the 4th or 5th intercostal space in the mid- or anterior- axillary line. Attention to technique in placing the chest tube is vital to avoid complications from the procedure. Applying the step-by-step technique presented, placement of a chest tube is a quick and safe procedure. Complications - frequently occurring when the tube is inserted with a steel trocar - include hemothorax, dislocation, lung lacerations, and injury to organs in the thoracic or abdominal cavity." © Georg Thieme Verlag KG Stuttgart · New York.

  9. THREE PORT LAPAROSCOPIC APPENDECTOMY TECHNIQUE WITH LOW COST AND AESTHETIC ADVANTAGE

    PubMed Central

    DOMENE, Carlos Eduardo; VOLPE, Paula; HEITOR, Frederico Almeida

    2014-01-01

    Introduction Despite dating more than 30 years after the first laparoscopic appendectomy, ileocecal appendix resection is still performed by laparotomy in more than 90% of cases, in our country. Aim To describe a technique for laparoscopic removal of the ileocecal appendix with three portals, at low cost and very good aesthetic appearance. Technique Three incisions, one umbilical and two suprapubic are made; permanent material used comprises: grasping forceps, hook, scissors, needle holders, three metal trocars and four other usual instruments, and a single strand of cotton. There is no need to use of operative extractors bags, clips, endoloops, staples or bipolar or harmonic energy instruments. Allows triangulation and instrumentation in the conventional manner. Conclusion The proposed technique is safe and reproducible, easily teachable, at very low cost and can be applied in general hospitals with conventional laparoscopic equipment. PMID:25409972

  10. Laparoscopic repair of ureter damaged during laparoscopic hysterectomy: Presentation of two cases

    PubMed Central

    Api, Murat; Boza, Ayşen; Kayataş, Semra; Boza, Barış

    2017-01-01

    Ureter injuries are uncommon but dreaded complications in gynecologic surgery and a frequent cause of conversion to laparotomy. Recently, a few papers reported the repair of gynecologic ureteral injuries using laparoscopy with encouraging results. In these case reports, we aimed to present two laparoscopically repaired ureter injuries during total laparoscopic hysterectomies (TLH). In the first case, the ureter was transected during the dissection of the cardinal ligament, approximately 7 to 8 cm distal to the ureterovesical junction (UVJ), and in the second case, it was damaged approximately 10 cm distal to the UVJ. Both transections were identified during surgery. The injured ureter was repaired without converting to laparotomy or additional trocar insertion. Ureteroureterostomy was performed in both cases uneventfully. Although ureteric injury is a rare complication during TLH, it can be managed by the same surgeon laparoscopically during the same procedure. PMID:29085711

  11. Simultaneous laparoscopic adrenalectomy and laparoscopic nephron-sparing surgery – new experience with port placement

    PubMed Central

    Panek, Wojciech; Lewandowski, Jaroslaw; Tuchendler, Tomasz; Urbańczyk, Grzegorz; Litarski, Adam; Apoznański, Wojciech

    2013-01-01

    The aim of the study was to describe simultaneous laparoscopic adrenalectomy and laparoscopic nephron-sparing surgery, to discuss the details of a convenient laparoscopic approach and the way of port placement, as well as to present a review of the literature concerning combined laparoscopic procedures. A 72-year-old woman was admitted to our department because of a tumor of the right adrenal gland and a small tumor of the right kidney. The patient underwent simultaneous laparoscopic adrenalectomy and laparoscopic nephron-sparing surgery. The postoperative period was uncomplicated. The patient was discharged from the hospital on the 4th postoperative day. We believe that the proposed way of trocar placement would help to avoid a ‘rollover’ problem between the laparoscope and a Satinsky clamp or a ‘crossing swords’ problem between a Satinsky clamp and manipulators. PMID:24501608

  12. Laparoscopic transgastric gastroplasty: a novel technique for a large esophagogastric fistula.

    PubMed

    McKenna, Daniel T; Ziegler, Kathryn; Selzer, Don

    2014-08-01

    Esophagogastric fistula is a rare complication related to severe inflammation at the gastroesophageal junction. Most causes are related to severe gastroesophageal reflux disease, previous surgery, or malignancy. This is the case of a 72-year-old man who had a laparoscopic Nissen fundoplication. He developed an esophageal obstruction from an intraesophageal pledget. It was removed laparoscopically, and the esophagotomy was buttressed with a Nissen fundoplication. Two months later he developed severe dysphagia, and an esophagogastric fistula was diagnosed. This was a large fistula measuring 20 mm in diameter. A novel hybrid technique was used to divide the fundoplication. Under endoscopic guidance, a 12-mm balloon-tipped trocar was inserted transgastrically. A linear-cutting surgical stapler was used to divide the fundoplication and reopen the gastroesophageal junction. The patient had no further dysphagia or gastroesophageal reflux.

  13. Robotic trans-abdominal transplant nephrectomy for a failed renal allograft.

    PubMed

    Mulloy, M R; Tan, M; Wolf, J H; D'Annunzio, S H; Pollinger, H S

    2014-12-01

    Minimally invasive surgery for removal of a failed renal allograft has not previously been reported. Herein, we report the first robotic trans-abdominal transplant nephrectomy (TN). A 34-year-old male with Alport's syndrome lost function of his deceased donor allograft after 12 years and presented with fever, pain over his allograft and hematuria. The operation was performed intra-abdominally using the Da Vinci Robotic Surgical System with four trocars. The total operative time was 235 min and the estimated blood loss was less than 25 cm(3). There were no peri-operative complications observed and the patient was discharged to home less than 24 h postoperatively. The utilization of robotic technology facilitated the successful performance of a minimally invasive, trans-abdominal TN. © Copyright 2014 The American Society of Transplantation and the American Society of Transplant Surgeons.

  14. Enticed by the punschrulle: Preliminary investigation of the Seve Nappe Complex's incorporation into the Scandinavian Caledonides via 'vacuum-cleaner' exhumation.

    NASA Astrophysics Data System (ADS)

    Barnes, Chris; Majka, Jaroslaw; Schneider, David; Bukala, Michal; Walczak, Katarzyna

    2017-04-01

    micas, are characterized by very fine-grained recrystallized Qz, mica (Ms) fish bundles and rotated, pre-kinematic Grt and Tur, illustrating strain localization which accommodated the exhumation of eclogite boudins. Kinematic orientations determined from mica-rich shear zones are variable; rigid eclogite boudins are likely controlling local shear sense. Compositional mapping of white mica reveals a narrow range of composition (61-73% XMs/27-39% XCel) regardless of degree of deformation experienced by the crystal. However, individual grains show patchy Mg-depleted/Al-enriched zones (70-84% XMs/16-30% XCel), which are spatially correlated with Bt-after-Ms reactions. Graphical representation of total Mg + Fe-content vs. excess Si-content of white mica illustrates a strong Tschermak substitution towards Ms end-member composition, with moderate Prl and Ti substitutions also contributing to the overall excess Si-content. Growth of Bt-after-Ms and the associated Tschermak substitution towards Ms-composition suggests a decrease in temperature during retrogressive metamorphism, perhaps marking the transition from lower-amphibolite to upper-greenschist facies. Future work on resolving the timing of exhumation of the SNC will involve in-situ 40Ar/39Ar dating of white mica and U-Pb depth profiling of zircon. This preliminary study regarding the petrology, mineral chemistry, and microstructures of the SNC host-rock in Norrbotten will be crucial for interpreting the geo/thermochronological results and will be instrumental for evaluating the vacuum-cleaner model. This work is financially supported by NCN "CALSUB" research project no. 2014/14/E/ST10/00321.

  15. Robotic hip arthroscopy in human anatomy.

    PubMed

    Kather, Jens; Hagen, Monika E; Morel, Philippe; Fasel, Jean; Markar, Sheraz; Schueler, Michael

    2010-09-01

    Robotic technology offers technical advantages that might offer new solutions for hip arthroscopy. Two hip arthroscopies were performed in human cadavers using the da Vinci surgical system. During both surgeries, a robotic camera and 5 or 8 mm da Vinci trocars with instruments were inserted into the hip joint for manipulation. Introduction of cameras and working instruments, docking of the robotic system and instrument manipulation was successful in both cases. The long articulating area of 5 mm instruments limited movements inside the joint; an 8 mm instrument with a shorter area of articulation offered an improved range of motion. Hip arthroscopy using the da Vinci standard system appears a feasible alternative to standard arthroscopy. Instruments and method of application must be modified and improved before routine clinical application but further research in this area seems justified, considering the clinical value of such an approach. Copyright 2010 John Wiley & Sons, Ltd.

  16. Laparoscopic management of cholecystocolic fistula

    PubMed Central

    CONDE, Lauro Massaud; TAVARES, Pedro Monnerat; QUINTES, Jorge Luiz Delduque; CHERMONT, Ronny Queiroz; PEREZ, Mario Castro Alvarez

    2014-01-01

    Introduction Cholecystocolic fistula is a rare complication of gallbladder disease. Its clinical presentation is variable and nonspecific, and the diagnosis is made, mostly, incidentally during intraoperative maneuver. Cholecystectomy with closure of the fistula is considered the treatment of choice for the condition, with an increasingly reproducible tendency to the use of laparoscopy. Aim To describe the laparoscopic approach for cholecystocolic fistula and ratify its feasibility even with the unavailability of more specific instruments. Technique After dissection of the communication and section of the gallbladder fundus, the fistula is externalized by an appropriate trocar and sutured manually. Colonic segment is reintroduced into the cavity and cholecystectomy is performed avoiding the conversion procedure to open surgery. Conclusion Laparoscopy for resolution of cholecystocolic fistula isn't only feasible, but also offers a shorter stay at hospital and a milder postoperative period when compared to laparotomy. PMID:25626940

  17. A Novel Shape Memory Alloy Annuloplasty Ring for Minimally Invasive Surgery: Design, Fabrication, and Evaluation

    PubMed Central

    Purser, Molly F.; Richards, Andrew L.; Cook, Richard C.; Osborne, Jason A.; Cormier, Denis R.; Buckner, Gregory D.

    2013-01-01

    A novel annuloplasty ring with a shape memory alloy core has been developed to facilitate minimally invasive mitral valve repair. In its activated (austenitic) phase, this prototype ring has comparable mechanical properties to commercial semi-rigid rings. In its pre-activated (martensitic) phase, this ring is flexible enough to be introduced through an 8-mm trocar and easily manipulated with robotic instruments within the confines of a left atrial model. The core is constructed of 0.50 mm diameter NiTi, which is maintained below its martensitic transition temperature (24 °C) during deployment and suturing. After suturing, the ring is heated above its austenitic transition temperature (37 °C, normal human body temperature) enabling the NiTi core to attain its optimal geometry and stiffness characteristics indefinitely. This article summarizes the design, fabrication, and evaluation of this prototype ring. Experimental results suggest that the NiTi core ring could be a viable alternative to flexible bands in robot-assisted minimally invasive mitral valve repair. PMID:20652747

  18. Fetoscopic single-layer repair of open spina bifida using a cellulose patch: preliminary clinical experience.

    PubMed

    Pedreira, Denise A L; Zanon, Nelci; de Sá, Renato A M; Acacio, Gregório L; Ogeda, Edilson; Belem, Teresa M L O U; Chmait, Ramen H; Kontopoulos, Eftichia; Quintero, Ruben A

    2014-11-01

    To report our preliminary clinical experience in the antenatal correction of open spina bifida (OSB) using a fetoscopic approach and a simplified closure technique. Four fetuses with lumbar-sacral defects were operated in utero from 25 to 27 weeks. Surgeries were performed percutaneously under general anesthesia using three trocars and partial carbon dioxide insufflation. After dissection of the neural placode, the surrounding skin was closed over a cellulose patch using a single continuous stitch. Surgical closure was successful in three of the four cases. All successful cases showed improvement of the hindbrain herniation and no neonatal neurosurgical repair was required in two cases. Delivery occurred between 31 and 33 weeks, and no fetal or neonatal deaths occurred. Ventriculoperitoneal shunting was not needed in two out of the 3 successful cases. Our preliminary experience suggests that definitive fetoscopic repair of OSB is feasible using our innovative surgical technique. A phase I trial for the fetoscopic correction of OSB with this technique is currently being conducted.

  19. Bio-inspired Nanoparticulate Medical Glues for Minimally Invasive Tissue Repair

    PubMed Central

    Lee, Yuhan; Xu, Chenjie; Sebastin, Monisha; Lee, Albert; Holwell, Nathan; Xu, Calvin; Miranda-Nieves, David; Mu, Luye; Lin, Charles

    2015-01-01

    Delivery of tissue glues through small-bore needles or trocars is critical for sealing holes, affixing medical devices, or attaching tissues together during minimally invasive surgeries. Inspired by the granule-packaged glue delivery system of sandcastle worms, we have developed a nanoparticulate formulation of a viscous hydrophobic light-activated adhesive based on poly(glycerol sebacate)-acrylate. Negatively charged alginate was used to stabilize the nanoparticulate surface to significantly reduce its viscosity and to maximize injectability through small-bore needles. The nanoparticulate glues can be concentrated to ~30w/v% dispersions in water that remain localized following injection. With the trigger of a positively charged polymer (e.g., protamine), the nanoparticulate glues can quickly assemble into a viscous glue that exhibits rheological, mechanical and adhesive properties resembling the native poly(glycerol sebacate)-acrylate based glues. This platform should be useful to enable the delivery of viscous glues to augment or replace sutures and staples during minimally invasive procedures. PMID:26227833

  20. A rare cause of bleeding after laparoscopic sleeve gastrectomy : pseudo-aneurysm of the gastro-omental artery.

    PubMed

    Mege, D; Louis, G; Berthet, B

    2013-01-01

    A serious complication of laparoscopic sleeve gastrectomy (LSG) is bleeding that is primarily located along the staples lines. Bleeding may be due to several causes, including hematomas, trocar sites, or visceral pseudo-aneurysms. We reported here a case of bleeding related to a pseudo-aneurysm of the gastro-omental artery. An LSG was performed on a 43-year-old woman (BMI = 46 kg/m2) without apparent surgical complications. Fifteen days later, she was admitted to the emergency department for hematemesis and symptoms of hemorrhagic shock. Abdominal computed tomography angiography revealed blood in the stomach, without a digestive leak, and active bleeding from a pseudo-aneurysm of the gastro-omental artery. An arterial embolisation was performed with the sandwich technique and angiographic guide wires and the placement of several detachable coils. The patient was discharged two days later. We demonstrated for the first time that post-LSG bleeding may involve a pseudo-aneurysm of the gastro-omental artery.

  1. How to improve laparoscopic access safety: ENDOTIP.

    PubMed

    2001-01-01

    To improve laparoscopic port safety, an observational study was conducted where tissue dynamics at port-site, during use of conventional push-through trocars, were analysed. Specific performance shaping factors (PSF) were identified that individually and collectively infer added risk to port creation. Having determined weaknesses of closed and open laparoscopic port insertion, a new interactive visual cannula insertion and removal system is presented and ergonomic instrument designed. This second generation access system avoids the identified PSFs and can anticipate danger. Error is recognised and corrected before patient harm occurs. With renewed interest in the US Congress to curb incidence of inadvertent medical error, endoscopists should revisit the fundamental first steps of laparoscopy, when more than half of all serious complications occur. Our culture of 'blaming the human' must evolve into a culture of safety and transparency, as inadvertent laparoscopic error is now less tolerated. Evidently, most serious laparoscopic access injuries are generally a system problem, and less of a surgeon or instrument issue.

  2. Palanivelu hydatid system for safe and efficacious laparoscopic management of hepatic hydatid disease.

    PubMed

    Palanivelu, C; Senthilkumar, R; Jani, K; Rajan, P S; Sendhilkumar, K; Parthasarthi, R; Rajapandian, S

    2006-12-01

    Hydatid disease, being endemic in several areas of the world, is of interest even to surgeons in non-endemic areas because they may encounter the disease due to ease and rapidity of travel as well as immigration. We describe a new device for laparoscopic management of hepatic hydatid disease. The special trocar-cannula system--the Palanivelu hydatid system (PHS)--and the technique of operation are described. A total of 75 patients were operated on using this technique. In 83.3% of patients, only evacuation of the hydatid cyst by the PHS was done. In 13.7%, this was followed by left lobectomy because the cysts were large, occupying almost the entire left lobe of the liver. The remnant cavity was dealt with by omentoplasty. The average follow-up period was 5.9 years, during which there were no recurrences. PHS is successful in preventing spillage, evacuating the contents of hydatid cysts, performing transcystic fenestration, and for dealing with cyst-biliary communications.

  3. Beyond Widgets -- Systems Incentive Programs for Utilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Regnier, Cindy; Mathew, Paul; Robinson, Alastair

    Utility incentive programs remain one of the most significant means of deploying commercialized, but underutilized building technologies to scale. However, these programs have been largely limited to component-based products (e.g., lamps, RTUs). While some utilities do provide ‘custom’ incentive programs with whole building and system level technical assistance, these programs require deeper levels of analysis, resulting in higher program costs. This results in custom programs being restricted to utilities with greater resources, and are typically applied mainly to large or energy-intensive facilities, leaving much of the market without cost effective access and incentives for these solutions. In addition, with increasinglymore » stringent energy codes, cost effective component-based solutions that achieve significant savings are dwindling. Building systems (e.g., integrated façade, HVAC and/or lighting solutions) can deliver higher savings that translate into large sector-wide savings if deployed at the scale of these programs. However, systems application poses a number of challenges – baseline energy use must be defined and measured; the metrics for energy and performance must be defined and tested against; in addition, system savings must be validated under well understood conditions. This paper presents a sample of findings of a project to develop validated utility incentive program packages for three specific integrated building systems, in collaboration with Xcel Energy (CO, MN), ComEd, and a consortium of California Public Owned Utilities (CA POUs) (Northern California Power Agency(NCPA) and the Southern California Public Power Authority(SCPPA)). Furthermore, these program packages consist of system specifications, system performance, M&V protocols, streamlined assessment methods, market assessment and implementation guidance.« less

  4. Science in Service to Society - A Review of Applied Science & Decision Support Development Serving Multiple Economic Sectors

    NASA Astrophysics Data System (ADS)

    Mahoney, W. P., III

    2015-12-01

    For more than 30 years, the Research Applications Laboratory (RAL) of the National Center for Atmospheric Research (NCAR) has conducted fundamental and applied research focused on developing decision support tools spanning multiple end-user groups representing a variety of economic sectors. Technology transfer is a primary mission of the laboratory where innovation is a key attribute and multidisciplinary research and development are the norm. Application areas include, aviation, surface transportation, wind and solar energy prediction, climate, weather and health, numerical weather prediction, biological and chemical plume dispersion for homeland security, flood prediction and water resource management, soil condition and crop maturity prediction among other application areas. The majority of the developed capabilities have been operationalized by the public, private, and academic sectors. Several commercial companies have been successfully formed around the technologies (e.g., Weather Information Technologies, Inc., Peak Weather Resources, Inc., and Global Weather Corporation) and many existing companies have improved their products by utilizing the RAL-developed weather system advancements (The Weather Channel, WSI, Schneider Electric, Xcel Energy, United Airlines, Vaisala, Panasonic, Idaho Power, etc.). The economic benefit estimates of implementing these technologies have ranged from billions of dollars in avoided commercial aircraft accidents over the last 30 years to 10s of millions of dollars of annual savings by state departments of transportation via more efficient ice and snow maintenance operations. Research and development at RAL is connected to the Broader Impacts Criterion of NSF and its focus on research that results in significant economic or societal impact. This talk will describe our research-to-operations process and discuss several technology transfer examples that have led to commercial opportunities.

  5. Port-site incisional hernia - A case series of 54 patients.

    PubMed

    Lambertz, A; Stüben, B O; Bock, B; Eickhoff, R; Kroh, A; Klink, C D; Neumann, U P; Krones, C J

    2017-02-01

    The increased use of laparoscopy has resulted in certain complications specifically associated with the laparoscopic approach, such as port-site incisional hernia (PIH). Until today, it is not finally clarified if port-site closure should be performed by fascia suture or not. Furthermore, the optimal treatment strategy in PIH (suture vs. mesh) is still widely unclear. The aim of this study was to present our experience with PIH in two independent departments and to derive possible treatment strategies from these results. Between 2003 and 2013, 54 patients were operated due to port-site incisional hernia in two surgical centres. Their data were collected and retrospectively analyzed depending on surgical technique of port-site hernia repair (Mesh repair group, n = 13 vs. Suture only group, n = 41). Port site incisional hernia occurred in 96% (52 patients) after the use of trocars with 10 mm or larger diameter. Patients treated with mesh repair had significantly higher body mass index (BMI) (32 ± 9 vs. 27 ± 4; p = 0.023) and significantly higher rates of cardiac diseases (77% vs. 39%; p = 0.026) than patients in the suture only group. Mean fascial defect size was significantly larger in the Mesh repair group than in the Suture only group (31 ± 24 mm vs. 24 ± 32 mm; p = 0.007) and mean time of operation was significantly longer in patients operated with mesh repair (83 ± 47 min vs. 40 ± 28 min; p < 0.001). There were no significant differences in mean hospital stay (3 ± 4 days; p = 0.057) and hernia recurrence rates (9%; p = 0.653) between study groups. Mean time of follow up was 32 ± 35 months. In Port sites of 10 mm and larger diameter fascia should be closed by suture, whereas the risk of hernia development in 5 mm trocar placements seems to be a rare complication. Port-site incisional hernia should be treated by suture or mesh repair depending on fascial defect size and the patients' risk factors regarding preexisting

  6. Aortic perforation sustained at laparoscopy.

    PubMed

    Lynn, S C; Katz, A R; Ross, P J

    1982-04-01

    A major type of complication associated with laparoscopic sterilization has been overcome by changing from electrocautery to either the Hulka clip or silicone rubber band technique, but major puncture and laceration injuries continue at the rate of 0.5% to 2%. The only case of major vascular injury incurred in over 4000 laparoscopic sterilization procedures performed from 1974 through 1980 at the Hermann Hospital in Houston, Texas is reported. A 40-year-old white female, para 3-0-1-3, was admitted for a laparoscopic sterilization procedure. The physical examination was within normal limits. The procedure was carried out by insufflating the peritoneal cavity with 2 liters of CO2 through a 12-cm Verres needle placed subumbilically while testing the abdomen with towel clips. Insufflating pressure never rose above 15 mm of mercury, and an adequate pneumoperitoneum was obtained. With the patient in the Trendelenburg position the trocar was inserted and the laparoscope placed with no apparent difficulty. The Falope Ring applicator sleeve was inserted suprapublically under direct vision. After placing the rings bilaterally, the cul-de-sac was noted to contain approximately 300 cc of blood. This was aspirated, but blood slowly reaccumulated in the cul-de-sac. Laparoscopic examination provided inadequate visualization of the posterior surface of the mesosalpinges, and it was decided to perform laparotomy. Upon opening the abdomen, the pulse rose from 85 to 110 per minute and the blood pressure fell from 90/60 to 50/0 mm HG. Rapid infusion of isotonic crystalloid and 3 units of packed red blood cells restored the patient's vital signs to normal. Examination of the abdominal wall and pelvic organs was normal, but a retroperitoneal hematoma was discovered in the area of the sacral promontroy. The posterior peritoneum was opened, and a 13 x 15-cm hematoma was evacuated. A 3-mm puncture wound was noted in the anterior wall of the aorta 3 cm cephalad to the bifurcation. The

  7. Efficacy of periportal infiltration and intraperitoneal instillation of ropivacaine after laparoscopic surgery in children.

    PubMed

    Di Pace, Maria Rita; Cimador, Marcello; Catalano, Pieralba; Caruso, Anna; Sergio, Maria; Casuccio, Alessandra; De Grazia, Enrico

    2009-12-01

    Postoperative pain is less intense after laparoscopic than after open surgery. However, minimally invasive surgery is not a a pain-free procedure. Many trials have been done in adults using intraperitoneal and/or incisional local anesthetic, but similar studies have not yet been reported in the literature in children. The aim of this study was to evaluate the analgesic effect of periportal infiltration and intraperitoneal instillation of ropivacaine in children undergoing laparoscopic surgery. Thirty patients who underwent laparoscopic surgery were randomly allocated to one of three groups. Group A (n = 10) received local infiltration of port sites with 10 mL of ropivacaine. Group B (n = 10) received both an infiltration of port sites with 10 mL of ropivacaine and an intraperitoneal instillation of 10 mL of ropivacaine. Group C did not receive any analgesic treatment. The local anesthetic was always administered at the end of surgery. The degree of postoperative abdominal parietal pain, abdominal visceral pain, and shoulder pain was assessed by using a Wong-Baker pain scale and a Visual Analog Scale (VAS) at 3, 6 12, and 24 hours postoperatively. The following parameters were also evaluated: rescue analgesic treatment, length of hospital stay, and time of return to normal activities. Three hours after operation, patients had low pain scores. Six and 12 hours postoperatively, the abdominal parietal pain was significantly higher (P < 0.0005) in group C than in the other two groups, both treated with an infiltration at the trocar sites; mean intensity of abdominal visceral pain was significantly lower (P < 0.0005) in group B than in groups A and C; the overall incidence of shoulder pain was significantly lower (P < 0.0005) in group B patients than in patients of groups A and C. At 20 hours postoperatively, pain scores were significantly reduced of intensity in all groups. Rescue analgesic treatment was significantly higher in group C, if compared to groups A and B 12

  8. Physician Education on Controllable Costs Significantly Reduces Cost of Laparoscopic Hysterectomy.

    PubMed

    Croft, Katherine; Mattingly, Patricia J; Bosse, Patrick; Naumann, R Wendel

    2017-01-01

    To determine whether educating surgeons about their controllable instrumentation costs by providing cost data on total laparoscopic hysterectomy (LH) would reduce the cost of this procedure. Prospective cohort study (Canadian Task Force classification III). Academic-affiliated community hospital. Patients who underwent LH between April 2014 and March 2015 with surgeons who performed at least 10 LHs during that time period, along with a second group who underwent LH with the same cohort of surgeons between July 2015 and September 2015. The cost of LH was calculated for all surgeons who performed more than 10 LHs between April 2014 and March 2015. Itemized cost data were collected. The individual costs, as well as a summary of the data, were shared with all of the physicians to highlight areas of potential cost savings. The costs were then measured for 3 months after the educational intervention (July-September 2015) to gauge the impact of physician cost education. Thirteen surgeons met the criteria for inclusion in this analysis. Together, they performed 271 hysterectomies, with an average instrumentation cost of $1539.47 ± $294.16 and an average operating room time of 178 ± 26 minutes. Bipolar instrument choice represented 37% of the baseline costs, followed by 10% for trocar, 9% for cuff closure, and 8% for uterine manipulator. This same group of surgeons performed a total of 69 hysterectomies in the 3-month follow-up period of July-September 2015, with an average instrumentation cost of $1282.62 ± $235.03 and an average operating room time of 163 ± 50 minutes. There was statistically significant cost reduction of $256.85 ± $190.69 (p = .022), with no significant change in operating room time. Bipolar instrument cost decreased significantly, by $130.02 ± $125.02 (p = .021), representing 51% of the total cost savings. Trocar, cuff closure, and uterine manipulator costs were not significant sources of cost savings on average, but did represent

  9. [Laparoscopic cholecystectomy with transgastric gallbladder extraction: a new therapeutic approach].

    PubMed

    Jurczak, F; Pousset, J-P; Raffaitin, P

    2009-02-01

    To evaluate a newly developed cholecystectomy technique which combines classical dissection with currently available mini-instrumentation (3 and 5 mm) and removal of the gallbladder through a short gastrotomy. After a feasibility study, we set up a protocol for this procedure using instrumentation currently available on the market. The resected gallbladder was removed through a short gastrotomy on the anterior gastric wall, thereby minimizing abdominal wall trauma and permitting the patient to resume physical activity more quickly with no risk of trocar herniation. Cholecystectomy was performed by the described technique in 18 of 23 eligible patients between April 2008 and August 2008. There were seven males and 11 females with a mean age of 48 (range: 28-77); median BMI was 30 kg/m2 (range: 22-36). Eleven patients had a gallstone larger than 12 mm. There were no postoperative complications and recovery was rapid for all patients in our study. This procedure is technically feasible, safe and reproducible; results are good with minimal trauma to the abdominal wall. Normal physical activity can be rapidly resumed with no risk of incisional hernia.

  10. Conventional fascial technique versus mesh repair for advanced pelvic organ prolapse: Analysis of recurrences in treated and untreated compartments.

    PubMed

    Damiani, G R; Riva, D; Pellegrino, A; Gaetani, M; Tafuri, S; Turoli, D; Croce, P; Loverro, G

    2016-01-01

    117 women with severe pelvic organ prolapse (POP; stage > 2) were enrolled to elucidate a 24-month outcome of POP surgery, using conventional or mesh repair with 3 techniques. 59 patients underwent conventional repair and 58 underwent mesh repair. Two types of mesh were used: a trocar-guided transobturator polypropylene (Avaulta, Bard Inc.) and a porcine dermis mesh (Pelvisoft, Bard Inc.). Women with recurrences, who underwent previous unsuccessful conventional repair, were randomised. Primary outcome was the evaluation of anatomic failures (prolapse stage > 1) in treated and untreated compartments. Anatomic failure was observed in 11 of 58 patients (19%; CI 8.9-29) in the mesh group and in 16 of 59 patients (27.1%; p value = 0.3) in the conventional group. 9 of 11 failures in the mesh group (15.5%; CI 6.2-24.8) were observed in the untreated compartment (de novo recurrences), 14.3% in Pelvisoft and 16.7% in Avaulta arm, while only 1 recurrence in the untreated compartment (1.7%) was observed in the conventional group (odds ratio 10.6, p = 0.03).

  11. Advantages and disadvantages of pinless external fixation.

    PubMed

    Thomas, S R; Giele, H; Simpson, A H

    2000-12-01

    The AO pinless external fixator (PEF) uses trocar tipped clamps to grip the outer tibial cortex rather than pins to transfix it. Its main advantage is to avoid further contamination of the medullary canal in open tibial fractures where a nail may subsequently be used. We tested the anatomical safety of this device and its effect on plastic surgical procedures compared with a standard unilateral external fixator (UEF).The PEF and UEF were placed on two amputated limbs which were then dissected. Structures at risk were traced on ten cadaver limbs. We found that important anatomical structures were endangered by the PEF and that safe zones could not always be defined. The UEF avoided these structures. Plastic surgical approaches were made more difficult by the PEF which imposed limitations on local flap design and endangered the arterial perforators which supply them. We conclude that safety is compromised by the PEF because margins for error are small. It poses additional problems in soft tissue reconstruction and highlights the need for co-operation between plastic surgical and orthopaedic teams in choice of fixation device.

  12. Virtual modeling of robot-assisted manipulations in abdominal surgery.

    PubMed

    Berelavichus, Stanislav V; Karmazanovsky, Grigory G; Shirokov, Vadim S; Kubyshkin, Valeriy A; Kriger, Andrey G; Kondratyev, Evgeny V; Zakharova, Olga P

    2012-06-27

    To determine the effectiveness of using multidetector computed tomography (MDCT) data in preoperative planning of robot-assisted surgery. Fourteen patients indicated for surgery underwent MDCT using 64 and 256-slice MDCT. Before the examination, a specially constructed navigation net was placed on the patient's anterior abdominal wall. Processing of MDCT data was performed on a Brilliance Workspace 4 (Philips). Virtual vectors that imitate robotic and assistant ports were placed on the anterior abdominal wall of the 3D model of the patient, considering the individual anatomy of the patient and the technical capabilities of robotic arms. Sites for location of the ports were directed by projection on the roentgen-positive tags of the navigation net. There were no complications observed during surgery or in the post-operative period. We were able to reduce robotic arm interference during surgery. The surgical area was optimal for robotic and assistant manipulators without any need for reinstallation of the trocars. This method allows modeling of the main steps in robot-assisted intervention, optimizing operation of the manipulator and lowering the risk of injuries to internal organs.

  13. Confocal microlaparoscope for imaging the fallopian tube

    NASA Astrophysics Data System (ADS)

    Wu, Tzu-Yu; Rouse, Andrew R.; Chambers, Setsuko K.; Hatch, Kenneth D.; Gmitro, Arthur F.

    2014-11-01

    Recent evidence suggests that ovarian cancer can originate in the fallopian tube. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. A rigid confocal microlaparoscope system designed to image the epithelial surface of the ovary in vivo was previously reported. A new confocal microlaparoscope with an articulating distal tip has been developed to enable in vivo access to human fallopian tubes. The new microlaparoscope is compatible with 5-mm trocars and includes a 2.2-mm-diameter articulating distal tip consisting of a bare fiber bundle and an automated dye delivery system for fluorescence confocal imaging. This small articulating device should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Ex vivo images of animal tissue and human fallopian tube using the new articulating device are presented along with in vivo imaging results using the rigid confocal microlaparoscope system.

  14. Robotic right colectomy using the Da Vinci Single-Site® platform: case report.

    PubMed

    Morelli, Luca; Guadagni, Simone; Caprili, Giovanni; Di Candio, Giulio; Boggi, Ugo; Mosca, Franco

    2013-09-01

    While single-port laparoscopy for abdominal surgery is technically challenging, the Da Vinci Single-Site® robotic surgery platform may help to overcome some of the difficulties of this rapidly evolving technique. The authors of this article present a case of single-incision, robotic right colectomy using this device. A 74-year-old female with malignant polyp of caecum was operated on with a single-site approach using the Da Vinci Single-Site® robotic surgery device. Resection and anastomosis were performed extra-corporeally after undocking the robot. The procedure was successfully completed in 200 min. No surgical complications occurred during the intervention and the post-operative stay and no conversion to laparotomy or additional trocars were required. To the best of our knowledge, this is the first case of right colectomy using the Da Vinci Single-Site® robotic surgery platform to be reported. The procedure is feasible and safe and its main advantages are restoration of triangulation and reduced instrument clashes. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Talonavicular joint arthroscopic portals: A cadaveric study of feasibility and safety.

    PubMed

    Xavier, Gabriel; Oliva, Xavier Martin; Rotinen, Mauri; Monzo, Mariano

    2016-09-01

    The objectives of the study were to evaluate the safety of hypothetical arthroscopic portals from talonavicular joint and to evaluate their reproducibility and enforceability. 19 cadaveric feet were marked and four arthroscopic portals were made (medial, dorsomedial, dorsolateral and lateral). The specimens were dissected in layers and the distances between neurovascular structures and the trocars were measured. Medial and dorsomedial portals were in average 8.3 and 8.7, respectively, to the saphenous vein and nerve. Dorsolateral portal was in average 8.1mm to the deep peroneal nerve and dorsalis pedis artery, and 9.1mm to the medial dorsal cutaneous branch of the superficial peroneal nerve. Lateral portal was in average 12.3mm to the intermediate dorsal cutaneous branch of the superficial peroneal nerve. Tested portals shown to have a good safety margin for the foot neurovascular deep dorsal structures and an acceptable safety margin for the superficial neurovascular structures. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  16. Chandelier Illumination for Descemet Membrane Endothelial Keratoplasty

    PubMed Central

    Hayashi, Takahiko; Yuda, Kentaro; Tsuchiya, Ayako; Oyakawa, Itaru; Mizuki, Nobuhisa; Kato, Naoko

    2017-01-01

    Purpose: To describe a simple technique that uses posterior chandelier illumination during Descemet membrane endothelial keratoplasty in cases of severe bullous keratopathy (BK). Methods: Five eyes of 4 patients with advanced BK undergoing Descemet membrane endothelial keratoplasty were retrospectively analyzed. The pupil of the host eye was not treated with mydriatic or miotic agents. The chandelier illuminator was inserted transconjunctivally into the vitreous cavity from the pars plana. Results: In all eyes, BK was secondary to laser iridotomy, which was performed for prevention or treatment of angle closure glaucoma. The implanted graft was clearly confirmed in the anterior chamber using activated chandelier illumination. The graft was immediately attached to the host cornea, with eventual healing of BK in all eyes. No complication involving insertion or removal of the 25-gauge trocar and the chandelier illuminator was observed. No vision-threatening complication was observed in any of the 5 eyes. Conclusions: The chandelier illuminator provided good visibility of the anterior chamber and enhanced the safety of surgery by preventing formation of an inverted graft. PMID:28644235

  17. LAPAROSCOPY AFTER PREVIOUS LAPAROTOMY

    PubMed Central

    Godinjak, Zulfo; Idrizbegović, Edin; Begić, Kerim

    2006-01-01

    Following the abdominal surgery, extensive adhesions often occur and they can cause difficulties during laparoscopic operations. However, previous laparotomy is not considered to be a contraindication for lap-aroscopy. The aim of this study is to present that an insertion of Veres needle in the region of umbilicus is a safe method for creating a pneumoperitoneum for laparoscopic operations after previous laparotomy. In the last three years, we have performed 144 laparoscopic operations in patients that previously underwent one or two laparotomies. Pathology of digestive system, genital organs, Cesarean Section or abdominal war injuries were the most common causes of previous laparotomy. During those operations or during entering into abdominal cavity we have not experienced any complications, while in 7 patients we performed conversion to laparotomy following the diagnostic laparoscopy. In all patients an insertion of Veres needle and trocar insertion in the umbilical region was performed, namely a technique of closed laparoscopy. Not even in one patient adhesions in the region of umbilicus were found, and no abdominal organs were injured. PMID:17177649

  18. Bioinspired Nanoparticulate Medical Glues for Minimally Invasive Tissue Repair.

    PubMed

    Lee, Yuhan; Xu, Chenjie; Sebastin, Monisha; Lee, Albert; Holwell, Nathan; Xu, Calvin; Miranda Nieves, David; Mu, Luye; Langer, Robert S; Lin, Charles; Karp, Jeffrey M

    2015-11-18

    Delivery of tissue glues through small-bore needles or trocars is critical for sealing holes, affixing medical devices, or attaching tissues together during minimally invasive surgeries. Inspired by the granule-packaged glue delivery system of sandcastle worms, a nanoparticulate formulation of a viscous hydrophobic light-activated adhesive based on poly(glycerol sebacate)-acrylate is developed. Negatively charged alginate is used to stabilize the nanoparticulate surface to significantly reduce its viscosity and to maximize injectability through small-bore needles. The nanoparticulate glues can be concentrated to ≈30 w/v% dispersions in water that remain localized following injection. With the trigger of a positively charged polymer (e.g., protamine), the nanoparticulate glues can quickly assemble into a viscous glue that exhibits rheological, mechanical, and adhesive properties resembling the native poly(glycerol sebacate)-acrylate based glues. This platform should be useful to enable the delivery of viscous glues to augment or replace sutures and staples during minimally invasive procedures. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Transumbilical single port laparoscopic surgery for the treatment of concomitant disease.

    PubMed

    Lee, Jun Suh; Hong, Tae Ho; Park, Byung Joon; Kim, Jin Jo

    2013-06-01

    We report our experience of transumbilical single port laparoscopic surgery (TUSPLS) for multiple concomitant intraabdominal pathologies, and assess the feasibility of this technique with several technical tips. Various combined procedures using TUSPLS were performed since April, 2008. All records of concomitant laparoscopic procedures using TUSPLS were searched at three hospitals. Forty-one patients underwent 82 combined procedures using TUSPLS in a single session. The perioperative outcomes of simultaneously performed cholecystectomy and ovarian cystectomy using TUSPLS (n = 14) are compared with those of using CLS (n = 11). The operating time was significantly longer with the TUSPLS method than with the CLS method. However, postoperative convalescent outcomes such as postoperative hospital stay, VAS pain score, and required analgesics showed no differences between the two methods. Also, there were no significant operative complications associated with the two methods. Fewer trocars were used with the TUSPLS method. Combined laparoscopic procedures for various concomitant pathologies in the abdomen can be performed using transumbilical single port laparoscopic surgery without increasing morbidity or hospital stay in patients with acceptable risk.

  20. Injectible candidate sealants for fetal membrane repair: Bonding and toxicity in vitro

    PubMed Central

    Bilic, Grozdana; Brubaker, Carrie; Messersmith, Phillip B.; Mallik, Ajit S.; Quinn, Thomas M.; Haller, Claudia; Done, Elisa; Gucciardo, Leonardo; Zeisberger, Steffen M.; Zimmermann, Roland; Deprest, Jan; Zisch, Andreas H.

    2010-01-01

    Objective This study was undertaken to test injectible surgical sealants that are biocompatible with fetal membranes, eventually for closure of iatrogenic membrane defects. Study Design Dermabond, Histoacryl, Tissucol fibrin glue, and three types of in situ forming poly(ethylene glycol)-based polymer hydrogels were tested for acute toxicity upon direct contact with fetal membranes for 24h. For determination of elution toxicity, extracts of sealants were incubated on amnion cell cultures for 72h. Bonding and toxicity was assessed through morphological and/or biochemical analysis. Results Extracts of all adhesives were non-toxic for cultured cells. However, only Tissucol and one type of poly(ethylene glycol)-based hydrogel, mussel-mimetic tissue adhesive, showed efficient, non-disruptive, non-toxic bonding to fetal membranes. Mussel-mimetic tissue adhesive applied over membrane defects created with a 3.5 mm trocar accomplished leak-proof closure that withstood membrane stretch in an in vitro model. Conclusion A synthetic hydrogel-type tissue adhesive emerged as potential sealing modality for iatrogenic membrane defects that merits further evaluation in vivo. PMID:20096254

  1. Dual lumen transducer probes for real-time 3-D interventional cardiac ultrasound.

    PubMed

    Lee, Warren; Idriss, Salim F; Wolf, Patrick D; Smith, Stephen W

    2003-09-01

    We have developed dual lumen probes incorporating a forward-viewing matrix array transducer with an integrated working lumen for delivery of tools in real-time 3-D (RT3-D) interventional echocardiography. The probes are of 14 Fr and 22 Fr sizes, with 112 channel 2-D arrays operating at 5 MHz. We obtained images of cardiac anatomy and simultaneous interventional device delivery with an in vivo sheep model, including: manipulation of a 0.36-mm diameter guidewire into the coronary sinus, guidance of a transseptal puncture using a 1.2-mm diameter Brockenbrough needle, and guidance of a right ventricular biopsy using 3 Fr biopsy forceps. We have also incorporated the 22 Fr probe within a 6-mm surgical trocar to obtain apical four-chamber ultrasound (US) scans from a subcostal position. Combining the imaging catheter with a working lumen in a single device may simplify cardiac interventional procedures by allowing clinicians to easily visualize cardiac structures and simultaneously direct interventional tools in a RT3-D image.

  2. Solo surgery--early results of robot-assisted three-dimensional laparoscopic hysterectomy.

    PubMed

    Tuschy, Benjamin; Berlit, Sebastian; Brade, Joachim; Sütterlin, Marc; Hornemann, Amadeus

    2014-08-01

    Report of our initial experience in laparoscopic hysterectomy by a solo surgeon using a robotic camera system with three-dimensional visualisation. This novel device (Einstein Vision®, B. Braun, Aesculap AG, Tuttlingen, Germany) (EV) was used for laparoscopic supracervical hysterectomy (LASH) performed by one surgeon. Demographic data, clinical and surgical parameters were evaluated. Our first 22 cases, performed between June and November 2012, were compared with a cohort of 22 age-matched controls who underwent two-dimensional LASH performed by the same surgeon with a second surgeon assisting. Compared to standard two-dimensional laparoscopic hysterectomy, there were no significant differences regarding duration of surgery, hospital stay, blood loss or incidence of complications. The number of trocars used was significantly higher in the control group (p <.0001). All hysterectomies in the treatment group were performed without assistance of a second physician. Robot-assisted solo surgery laparoscopic hysterectomy is a feasible and safe procedure. Duration of surgery, hospital stay, blood loss, and complication rates are comparable to a conventional laparoscopic hysterectomy.

  3. One-year clinical outcomes after prolapse surgery with nonanchored mesh and vaginal support device.

    PubMed

    Zyczynski, Halina M; Carey, Marcus P; Smith, Anthony R B; Gauld, Judi M; Robinson, David; Sikirica, Vanja; Reisenauer, Christl; Slack, Mark

    2010-12-01

    The purpose of this study was to evaluate outcomes after standardized transvaginal prolapse repair with nonanchored mesh and a vaginal support device. Postoperative vaginal support was assessed by pelvic organ prolapse quantitative examination after repair of symptomatic stage II/III prolapse. Validated questionnaires assessed pelvic symptoms and sexual function. Visual analog scales quantified experience with the vaginal support device. One hundred thirty-six women received the planned surgery; 95.6% of the women returned for the 1-year assessment: 76.9% of the cases were stage 0/I; however, in 86.9% of the cases, the leading vaginal edge was above the hymen. Pelvic symptoms, quality of life, and sexual function improved significantly from baseline (P < .05). Median visual analog scale scores for vaginal support device awareness and discomfort were 2.6 and 1.2, respectively (0 = none; 10 = worst possible). Vaginal support, pelvic symptoms, and sexual function improved at 1 year, compared with baseline, after trocar-free prolapse repair with nonanchored mesh and a vaginal support device. Copyright © 2010 Mosby, Inc. All rights reserved.

  4. Laparoendoscopic single-site repair of bladder rupture using a home-made single-port device: initial experience of treatment for a traumatic intraperitoneal bladder rupture.

    PubMed

    Lee, Joo Yong; Kang, Dong Hyuk; Lee, Seung Wook

    2012-06-01

    We report our initial experience with a laparoendoscopic single-site (LESS) repair of a bladder rupture using a home-made single-port device. A 37-year-old man presented to the emergency department with complaints of voiding difficulty and gross hematuria after blunt trauma. Cystography and computed tomography revealed an intraperitoneal bladder rupture. The patient underwent LESS repair of a bladder rupture using the Alexis wound retractor, which was inserted through the umbilical incision. A home-made single-port device was made by fixing 6½ surgical gloves to the outer rim of the retractor and securing the glove finger to the end of 3 trocars with a tie. Using the flexible laparoscopic instruments and rigid instruments, LESS surgery was performed using a procedure similar to conventional laparoscopic surgery. The patient did not have any voiding problem after removal of the urethral Foley catheter on the 10th postoperative day. To our knowledge, this is the first published report of LESS repair of a traumatic bladder rupture using a home-made single-port device in the literature.

  5. Original single-incision laparoscopic cholecystectomy for acute inflammation of the gallbladder

    PubMed Central

    Sasaki, Kazunari; Watanabe, Goro; Matsuda, Masamichi; Hashimoto, Masaji

    2012-01-01

    AIM: To investigate the safety and feasibility of our original single-incision laparoscopic cholecystectomy (SILC) for acute inflamed gallbladder (AIG). METHODS: One hundred and ten consecutive patients underwent original SILC for gallbladder disease without any selection criteria and 15 and 11 of these were diagnosed with acute cholecystitis and acute gallstone cholangitis, respectively. A retrospective review was performed not only between SILC for AIG and non-AIG, but also between SILC for AIG and traditional laparoscopic cholecystectomy (TLC) for AIG in the same period. RESULTS: Comparison between SILC for AIG and non-AIG revealed that the operative time was longer in SILC for AIG (97.5 min vs 85.0 min, P = 0.03). The open conversion rate (2/26 vs 2/84, P = 0.24) and complication rate (1/26 vs 3/84, P = 1.00) showed no differences, but a need for additional trocars was more frequent in SILC for AIG (5/24 vs 3/82, P = 0.01). Comparison between SILC for AIG and TLC for AIG revealed no differences based on statistical analysis. CONCLUSION: Our original SILC technique was adequately safe and feasible for the treatment of acute cholecystitis and acute gallstone cholangitis. PMID:22408354

  6. LAPAROSCOPIC UNCINATECTOMY: A MORE CONSERVATIVE APPROACH TO THE UNCINATE PROCESS OF THE PANCREAS.

    PubMed

    Surjan, Rodrigo Cañada; Basseres, Tiago; Makdissi, Fabio Ferrari; Machado, Marcel Autran Cesar; Ardengh, José Celso

    2017-01-01

    The isolate resection of the uncinate process of the pancreas is a rarely described procedure but is an adequate surgery to treat benign and low grade malignancies of the uncinate process of the pancreas. To detail laparoscopic uncinatectomy technique and present the initial results. Patient is placed in supine position with the surgeon between legs. Three 5-mm, one 10-mm and one 12-mm trocars were used to perform the isolated resection of the uncinate process of the pancreas. Parenchymal transection is performed with harmonic scalpel. A hemostatic absorbable tissue is deployed over the area previously occupied by the uncinate process. A Waterman drain is placed. This procedure was applied to an asymptomatic 62-year-old male with biopsy proven low grade neuroendocrine tumor of the pancreatic uncinate process. A laparoscopic pancreaticoduodenectomy was proposed. During the initial surgical evaluation, intraoperative sonography was performed and disclosed that the lesion was a few millimeters away from the Wirsung. The option was to perform a laparoscopic uncinatectomy. Postoperative period until full recovery was swift and uneventful. Laparoscopic uncinatectomy is a safe and efficient procedure when performed by surgical teams with large experience in minimally invasive biliopancreatic procedures.

  7. The PASTA Bridge: A Technique for the Arthroscopic Repair of PASTA Lesions.

    PubMed

    Hirahara, Alan M; Andersen, Wyatt J

    2017-10-01

    PASTA (partial articular supraspinatus tendon avulsion) lesions of greater than 50% thickness are usually repaired, whereas those of less than 50% thickness receive subacromial decompression and debridement. However, tears of greater than 25% thickness of the tendon result in increased strain of the adjacent, intact tendon fibers. Re-creating the tendon footprint at the greater tuberosity is the goal of a repair. Transtendon repairs have been considered the gold standard in repair but have shown varying outcomes and are technically difficult procedures. This report details the PASTA bridge-a technique for the arthroscopic, percutaneous repair of PASTA lesions. The PASTA bridge uses a spinal needle to ensure the repair includes the leading edge of the good tissue and is at the appropriate angle and area. Most procedures use a knife or trocar blindly to access the joint to place anchors, which has the potential to damage surrounding tissues and result in poor anchor and suture placement. The PASTA bridge is a safe, reliable procedure that is easily reproducible and appropriate for surgeons of all experience levels and should be strongly considered when repairing PASTA lesions.

  8. An ultrasonically powered implantable micro-oxygen generator (IMOG).

    PubMed

    Maleki, Teimour; Cao, Ning; Song, Seung Hyun; Kao, Chinghai; Ko, Song-Chu Arthur; Ziaie, Babak

    2011-11-01

    In this paper, we present an ultrasonically powered implantable micro-oxygen generator (IMOG) that is capable of in situ tumor oxygenation through water electrolysis. Such active mode of oxygen generation is not affected by increased interstitial pressure or abnormal blood vessels that typically limit the systemic delivery of oxygen to hypoxic regions of solid tumors. Wireless ultrasonic powering (2.15 MHz) was employed to increase the penetration depth and eliminate the directional sensitivity associated with magnetic methods. In addition, ultrasonic powering allowed for further reduction in the total size of the implant by eliminating the need for a large area inductor. IMOG has an overall dimension of 1.2 mm × 1.3 mm × 8 mm, small enough to be implanted using a hypodermic needle or a trocar. In vitro and ex vivo experiments showed that IMOG is capable of generating more than 150 μA which, in turn, can create 0.525 μL/min of oxygen through electrolytic disassociation. In vivo experiments in a well-known hypoxic pancreatic tumor models (1 cm (3) in size) also verified adequate in situ tumor oxygenation in less than 10 min.

  9. Single-Port Surgery: Laboratory Experience with the daVinci Single-Site Platform

    PubMed Central

    Haber, Georges-Pascal; Kaouk, Jihad; Kroh, Matthew; Chalikonda, Sricharan; Falcone, Tommaso

    2011-01-01

    Background and Objectives: The purpose of this study was to evaluate the feasibility and validity of a dedicated da Vinci single-port platform in the porcine model in the performance of gynecologic surgery. Methods: This pilot study was conducted in 4 female pigs. All pigs had a general anesthetic and were placed in the supine and flank position. A 2-cm umbilical incision was made, through which a robotic single-port device was placed and pneumoperitoneum obtained. A data set was collected for each procedure and included port placement time, docking time, operative time, blood loss, and complications. Operative times were compared between cases and procedures by use of the Student t test. Results: A total of 28 surgical procedures (8 oophorectomies, 4 hysterectomies, 8 pelvic lymph node dissections, 4 aorto-caval nodal dissections, 2 bladder repairs, 1 uterine horn anastomosis, and 1 radical cystectomy) were performed. There was no statistically significant difference in operating times for symmetrical procedures among animals (P=0.3215). Conclusions: This animal study demonstrates that single-port robotic surgery using a dedicated single-site platform allows performing technically challenging procedures within acceptable operative times and without complications or insertion of additional trocars. PMID:21902962

  10. Comparison of titanium and biodegradable miniplates for fixation of mandibular fractures.

    PubMed

    Lee, Hyo-Bin; Oh, Ji-Su; Kim, Su-Gwan; Kim, Hak-Kyun; Moon, Seong-Yong; Kim, Young-Kyun; Yun, Pil-Young; Son, Jun-Sik

    2010-09-01

    The purpose of the present study was to compare the use of biodegradable miniplates and titanium miniplates for the fixation of mandibular fractures. BioSorb FX biodegradable plates and screws and titanium miniplates were used in 91 patients (65 males and 26 females; age range 11 to 69 years) for the treatment of mandibular fractures. The clinical and radiographic findings were recorded at 1, 3, 6, and 12 months after surgery. The overall complication rate was 4.41%. In the biodegradable plate group, infection occurred in 2 cases (4.26%) and was resolved by incision and drainage and antibiotics. In the titanium plate group, infection occurred in 1 case and plate fracture in 1 case (4.56%). The fractured plate was removed, and a new titanium miniplate was applied using a trocar. The infection was resolved with antibiotics. No adverse tissue reactions, malocclusions, or malunions occurred during the observation period. Our results have shown that the rate of morbidity is very low with the use of biodegradable plates and titanium plates, suggesting that biodegradable and titanium plates have the potential for successful use in the fixation of mandibular fractures. Crown Copyright 2010. Published by Elsevier Inc. All rights reserved.

  11. Single Incision Laparoscopic Assisted Appendectomy: Experience of 82 Cases

    PubMed Central

    Sinha, Anant Narayan; Deepak, Desh; Pandey, NK; Nandani

    2016-01-01

    Introduction Single Incision Laparoscopic Surgery (SILS) is one of the most recent developments which have been made in the field of minimal assesses surgery. It has potential advantages of less postoperative pain and better cosmesis, but at the same time, this procedure is time consuming and it increases the cost of surgery. Aim In this study, we evaluated the feasibility, safety and potential advantages of single incision laparoscopic assisted appendectomy. Materials and Methods Single incision laparoscopic assisted appendectomy was done in 82 patients who were diagnosed with acute or chronic appendicitis. A single 10mm incision made over right lower quadrant was used for placing two 5mm trocars and appendisectomy was done as in open surgery, after delivering out the appendix from the incision. Results Mean operative time was 32.56 ± 15.5 minutes. Mean post-operative pain scores as per visual analogue scalewere 6.5, 4.2 and 1.2 on 12 hours day 1 and day 2 after surgery respectively. Mean length of hospital stay was 1.4 ± 1.2 days. Conclusion Single incision laparoscopic appendectomy is safe and feasible. PMID:27437295

  12. Single-Site Nissen Fundoplication Versus Laparoscopic Nissen Fundoplication

    PubMed Central

    Sharp, Nicole E.; Vassaur, John

    2014-01-01

    Background: Advances in minimally invasive surgery have led to the emergence of single-incision laparoscopic surgery (SILS). The purpose of this study is to assess the feasibility of SILS Nissen fundoplication and compare its outcomes with traditional laparoscopic Nissen fundoplication. Methods: This is a retrospective study of 33 patients who underwent Nissen fundoplication between January 2009 and September 2010. Results: There were 15 SILS and 18 traditional laparoscopic Nissen fundoplication procedures performed. The mean operative time was 129 and 182 minutes in the traditional laparoscopic and single-incision groups, respectively (P = .019). There were no conversions in the traditional laparoscopic group, whereas 6 of the 15 patients in the SILS group required conversion by insertion of 2 to 4 additional ports (P = .0004). At short-term follow-up, recurrence rates were similar between both groups. To date, there have been no reoperations. Conclusions: SILS Nissen fundoplication is both safe and feasible. Short-term outcomes are comparable with standard laparoscopic Nissen fundoplication. Challenges related to the single-incision Nissen fundoplication include overcoming the lengthy learning curve and decreasing the need for additional trocars. PMID:25392613

  13. Comparison of economic and environmental impacts between disposable and reusable instruments used for laparoscopic cholecystectomy.

    PubMed

    Adler, S; Scherrer, M; Rückauer, K D; Daschner, F D

    2005-02-01

    The economic and environmental effects were compared between disposable and reusable instruments used for laparoscopic cholecystectomy. Special consideration was given to the processing of reusable instruments in the Miele G 7736 CD MCU washer disinfector and the resultant cost of sterilization. The instruments frequently used in their disposable form were identified with the help of surgeons. Thus, of all the instruments used for laparoscopic cholecystectomy, the disposable and reusable versions of trocars, scissors, and Veress cannula were compared. For the case examined in this study, the performance of laparoscopic cholecystectomy with disposable instruments was 19 times more expensive that for reusable instruments. The higher cost of using disposable instruments is primarily attributable to the purchase price of the instruments. The processing of reusable instruments has little significance in terms of cost, whereas the cost for disposing of disposable instruments is the least significant factor. The number of laparoscopic cholecystectomies performed per year does not substantially influence cost. In the authors' opinion, assessment of the environmental consequences shows that reusable instruments are environmentally advantageous. Considering the upward pressure of costs in hospitals, disposable instruments should be used for laparoscopic cholecystectomy only if they offer clear advantages over reusable instruments.

  14. Single-port access laparoscopic hysterectomy: a new dimension of minimally invasive surgery.

    PubMed

    Liliana, Mereu; Alessandro, Pontis; Giada, Carri; Luca, Mencaglia

    2011-01-01

    The fundamental idea is to have all of the laparoscopic working ports entering the abdominal wall through the same incision. Single-incision laparoscopic surgery is an alternative to conventional multiport laparoscopy. Single-access laparoscopy using a transumbilical port affords maximum cosmetic benefits because the surgical incision is hidden in the umbilicus and reduces morbidity of minimally invasive surgery. The advantages of single-access laparoscopic surgery may include less bleeding, infection, and hernia formation and better cosmetic outcome and less pain. The disadvantages and limitations include longer surgery time, difficulty in learning the technique, and the need for specialized instruments. This review summarizes the history of SPAL hysterectomy (single-port access laparoscopy), and emphasizes nomenclature, surgical technique, instrumentation, and perioperative outcomes. Specific gynecological applications of single-port hysterectomy to date are summarized. Using the PubMed database, the English-language literature was reviewed for the past 40 years. Keyword searches included scarless, scar free, single-port/trocar/incision, single-port access laparoscopic hysterectomy. Within the bibliography of selected references, additional sources were retrieved. The purpose of the present article was to review the development and current status of SPAL hysterectomy and highlight important advances associated with this innovative approach.

  15. Laparoscopic hernia repair and bladder injury.

    PubMed

    Dalessandri, K M; Bhoyrul, S; Mulvihill, S J

    2001-01-01

    Bladder injury is a complication of laparoscopic surgery with a reported incidence in the general surgery literature of 0.5% and in the gynecology literature of 2%. We describe how to recognize and treat the injury and how to avoid the problem. We report two cases of bladder injury repaired with a General Surgical Interventions (GSI) trocar and a balloon device used for laparoscopic extraperitoneal inguinal hernia repair. One patient had a prior appendectomy; the other had a prior midline incision from a suprapubic prostatectomy. We repaired the bladder injury, and the patients made a good recovery. When using the obturator and balloon device, it is important to stay anterior to the preperitoneal space and bladder. Prior lower abdominal surgery can be considered a relative contraindication to extraperitoneal laparoscopic hernia repair. Signs of gas in the Foley bag or hematuria should alert the surgeon to a bladder injury. A one- or two-layer repair of the bladder injury can be performed either laparoscopically or openly and is recommended for a visible injury. Mesh repair of the hernia can be completed provided no evidence exists of urinary tract infection. A Foley catheter is placed until healing occurs.

  16. Arthroscopic ankle arthrodesis with intra-articular distraction.

    PubMed

    Kim, Hyong Nyun; Jeon, June Young; Noh, Kyu Cheol; Kim, Hong Kyun; Dong, Quanyu; Park, Yong Wook

    2014-01-01

    Arthroscopic ankle arthrodesis has shown high rates of union comparable to those with open arthrodesis but with substantially less postoperative morbidity, shorter operative times, less blood loss, and shorter hospital stays. To easily perform arthroscopic resection of the articular cartilage, sufficient distraction of the joint is necessary to insert the arthroscope and instruments. However, sometimes, standard noninvasive ankle distraction will not be sufficient in post-traumatic ankle arthritis, with the development of arthrofibrosis and joint contracture after severe ankle trauma. In the present report, we describe a technique to distract the ankle joint by inserting a 4.6-mm stainless steel cannula with a blunt trocar inside the joint. The cannula allowed sufficient intra-articular distraction, and, at the same time, a 4.0-mm arthroscope can be inserted through the cannula to view the joint. Screws can be inserted to fix the joint under fluoroscopic guidance without changing the patient's position or removing the noninvasive distraction device and leg holder, which are often necessary during standard arthroscopic arthrodesis with noninvasive distraction. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. [Discussion on standardized implementation of laparoscopic radical lymphadenectomy for distal gastric cancer].

    PubMed

    Lyu, Zejian; Wang, Junjiang; Li, Yong

    2017-08-25

    Laparoscopic radical gastrectomy for gastric cancer has been widely applied in clinical practice, and its indications have been extended from early gastric cancer to advanced gastric cancer. It is acknowledged that laparoscopic radical gastrectomy is technically challenging because of the complexity of anatomy, rich blood supply, and extensive lymph node dissection. This paper primarily intends to share the experience of laparoscopic radical D2 gastrectomy for distal gastric cancer with details of choosing the location of Trocar, surgical approaches and the sequence of lymph node dissection. All the surgeries were performed at Department of General Surgery and Gastrointestinal Surgery, Guangdong General Hospital. The finding suggests that a correct laparoscopic Trocar placement is the foundation of adequate surgical field visualization. Under most circumstances, the observation hole should be around 2 cm below the umbilicus and the operating hole should be close to the bilateral clavicle midline. Furthermore, proper surgical approach and sequence of lymph node dissection are the prerequisites for successful laparoscopic radical D2 gastrectomy, as well as the reassurance of dissecting lymph node safely and comprehensively. The position of surgical team adopted in our center is that the surgeon stands to the left of the patient, with laparoscope operator stands in between patient's legs while the first assistant positions himself opposite the surgeon on the right side of the patient. This position correlates to the rules of sequential lymph node dissection, which is "from left to right", "from proximal to distal" and "from inferior to superior". Therefore, it is conductive to inferior and superior pylorus region dissection and it can effectively prevent subsidiary-injury. In our center, the procedure of lymph node dissection has been standardized: the initial step is to undergo station 4sb dissection and greater gastric curvature clearance; then change the patient

  18. New insights on the interaction between atmospheric flow and a full-scale 2.5 MW wind turbine

    NASA Astrophysics Data System (ADS)

    Chamorro, L. P.; Lee, S.; Olsen, D.; Milliren, C.; Marr, J.; Arndt, R.; Sotiropoulos, F.

    2012-12-01

    Power fluctuations and fatigue loads are among the most significant problems that wind turbines face throughout their lifetime. Atmospheric turbulence is the common driving mechanism that triggers instabilities on these quantities. Reducing the effects of the fluctuating flow on wind turbines is quite challenging due to the wide variety of length scales present in the boundary layer flow. Each group of these scales, which range from the order of a millimeter to kilometer and larger, plays a characteristic and distinctive role on the performance and structural reliability of wind turbines. This study seeks to contribute toward the understanding on the complex scale-to-scale interaction between wind turbine and flow turbulence. Novel insights into the physical mechanisms that govern the flow/turbine interaction will be discussed. To tackle the problem, we investigate the unsteady behavior of a full-scale 2.5 MW wind turbine under nearly neutral thermal stratification. The study is performed in the Eolos Wind Energy Research Field Station of the University of Minnesota. An instrumented 130 meter meteorological tower located upstream of a Clipper Liberty C96 wind turbine is used to characterize the turbulent flow and atmospheric conditions right upstream of the wind turbine. High resolution and synchronous measurements of the approach wind velocity at several heights, turbine power and strain at the tower foundation are used to determine the scale-to-scale interaction between flow and the wind turbine performance and its physical structure. The spectral distribution of the fluctuating turbine power and instantaneous stresses will be discussed in detail. Characteristic length scales playing a key role on the dynamics of the wind turbine as well as the distinctive effects of flow coherent motions and strong intermittent gusts will also be addressed. Funding was provided by the U.S. Department of Energy (DE-EE0002980) and Xcel Energy through the Renewable Development Fund

  19. Notched K-wire for low thermal damage bone drilling.

    PubMed

    Liu, Yao; Belmont, Barry; Wang, Yiwen; Tai, Bruce; Holmes, James; Shih, Albert

    2017-07-01

    The Kirschner wire (K-wire) is a common bone drilling tool in orthopedic surgery to affix fractured bone. Significant heat is produced due to both the cutting and the friction between the K-wire and the bone debris during drilling. Such heat can result in high temperatures, leading to osteonecrosis and other secondary injuries. To reduce thermal injury and other high-temperature associated complications, a new K-wire design with three notches along the three-plane trocar tip fabricated using a thin micro-saw tool is studied. These notches evacuate bone debris and reduce the clogging and heat generation during bone drilling. A set of four K-wires, one without notches and three notched, with depths of 0.5, 0.75, and 1mm, are evaluated. Bone drilling experiments conducted on bovine cortical bone show that notched K-wires could effectively decrease the temperature, thrust force, and torque during bone drilling. K-wires with notches 1mm deep reduced the thrust force and torque by approximately 30%, reduced peak temperatures by 43%, and eliminated blackened burn marks in bone. This study demonstrates that a simple modification of the tip of K-wires can effectively reduce bone temperatures during drilling. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Effect of oxiplex* films (PEO/CMC) on adhesion formation and reformation in rabbit models and on peritoneal infection in a rat model.

    PubMed

    Rodgers, K E; Schwartz, H E; Roda, N; Thornton, M; Kobak, W; diZerega, G S

    2000-04-01

    To assess the efficacy of Oxiplex (FzioMed, Inc., San Luis Obispo, CA) barriers. Film of polyethylene oxide and carboxymethylcellulose (Oxiplex) were tested for strength and tissue adherence. Films were selected for evaluation in models for biocompatability and adherence. Three films were selected for evaluation in efficacy studies, and one was evaluated for effects on bacterial peritonitis. Handling characteristics of Oxiplex film were evaluated via laparoscopy. University laboratory. Rabbits, rats, pigs. Placement of Oxiplex prototypes at the site of injury. Mechanical properties, biocompatibility, tissue adherence, adhesion development, infection potentiation, and device handling. Mechanical tests indicated that tensile strength and elongation were inversely correlated. All films tested had excellent tissue adherence properties. Selected films, based on residence time and biocompatibility, prevented adhesion formation in all animals and were highly efficacious in preventing adhesion reformation. The optimal Oxiplex prototype prevented adhesion reformation in 91% of the animals. This Oxiplex film, dyed to allow visualization, prevented adhesion reformation and did not affect bacterial peritonitis. In a laparoscopic model, the Oxiplex film, delivered in FilmSert forceps, via a 5.0-mm trocar, rapidly unfurled and could be easily applied to tissue with strong adherence. These data show development of an adhesion prevention material that is tissue adherent, can be placed via laparoscopy, and does not affect host resistance.

  1. Sources of pain in laparoendoscopic gynecological surgeons: An analysis of ergonomic factors and proposal of an aid to improve comfort.

    PubMed

    Lee, Sa Ra; Shim, Sunah; Yu, Taeri; Jeong, Kyungah; Chung, Hye Won

    2017-01-01

    Minimally invasive surgery (MIS) offers cosmetic benefits to patients; however, surgeons often experience pain during MIS. We administered an ergonomic questionnaire to 176 Korean laparoscopic gynecological surgeons to determine potential sources of pain during surgery. Logistic regression analysis was used to identify factors that had a significant impact on gynecological surgeons' pain. Operating table height at the beginning of surgery and during the operation were significantly associated with neck and shoulder discomfort (P <0.001). The ability to control the operating table height was the single factor most significantly associated with neck (P <0.001) and shoulder discomfort (P <0.001). Discomfort of the hand/digits was significantly associated with the trocar site (P = 0.035). The type of electrocautery activation switch and foot pedal were significantly related to surgeons' foot and leg discomfort (P <0.001). In evaluating the co-occurrence of pain in 4 different sites (neck, shoulder, back, hand/digits), the neck and shoulder were determined to have the highest co-occurrence of pain (Spearman's ρ = 0.64, P <0.001). These results provide guidance for identifying ergonomic solutions to reduce gynecological laparoscopic surgeons' pain. Based on our results, we propose the use of an ergonomic surgical step stool to reduce physical pain related to performing laparoscopic operations.

  2. Sources of pain in laparoendoscopic gynecological surgeons: An analysis of ergonomic factors and proposal of an aid to improve comfort

    PubMed Central

    Shim, Sunah; Yu, Taeri; Jeong, Kyungah; Chung, Hye Won

    2017-01-01

    Minimally invasive surgery (MIS) offers cosmetic benefits to patients; however, surgeons often experience pain during MIS. We administered an ergonomic questionnaire to 176 Korean laparoscopic gynecological surgeons to determine potential sources of pain during surgery. Logistic regression analysis was used to identify factors that had a significant impact on gynecological surgeons’ pain. Operating table height at the beginning of surgery and during the operation were significantly associated with neck and shoulder discomfort (P <0.001). The ability to control the operating table height was the single factor most significantly associated with neck (P <0.001) and shoulder discomfort (P <0.001). Discomfort of the hand/digits was significantly associated with the trocar site (P = 0.035). The type of electrocautery activation switch and foot pedal were significantly related to surgeons’ foot and leg discomfort (P <0.001). In evaluating the co-occurrence of pain in 4 different sites (neck, shoulder, back, hand/digits), the neck and shoulder were determined to have the highest co-occurrence of pain (Spearman’s ρ = 0.64, P <0.001). These results provide guidance for identifying ergonomic solutions to reduce gynecological laparoscopic surgeons’ pain. Based on our results, we propose the use of an ergonomic surgical step stool to reduce physical pain related to performing laparoscopic operations. PMID:28910316

  3. Cost variation in a laparoscopic cholecystectomy and the association with outcomes across a single health system: implications for standardization and improved resource utilization.

    PubMed

    Brauer, David G; Hawkins, William G; Strasberg, Steven M; Brunt, L Michael; Jaques, David P; Mercurio, Nicholas R; Hall, Bruce L; Fields, Ryan C

    2015-12-01

    Payers and regulatory bodies are increasingly placing emphasis on cost containment, quality/outcome measurement and transparent reporting. Significant cost variation occurs in many operative procedures without a clear relationship with outcomes. Clear cost-benefit associations will be necessary to justify expenditures in the era of bundled payment structures. All laparoscopic cholecystectomies (LCCKs) performed within a single health system over a 1-year period were analysed for operating room (OR) supply cost. The cost was correlated with American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) outcomes. From July 2013 to June 2014, 2178 LCCKs were performed by 55 surgeons at seven hospitals. The median case OR supply cost was $513 ± 156. There was variation in cost between individual surgeons and within an individual surgeon's practice. There was no correlation between cost and ACS NSQIP outcomes. The majority of cost variation was explained by selection of trocar and clip applier constructs. Significant case OR cost variation is present in LCCK across a single health system, and there is no clear association between increased cost and NSQIP outcomes. Placed within the larger context of overall cost, the opportunity exists for improved resource utilization with no obvious risk for a reduction in the quality of care. © 2015 International Hepato-Pancreato-Biliary Association.

  4. Extraocular surgery for implantation of an active subretinal visual prosthesis with external connections: feasibility and outcome in seven patients.

    PubMed

    Besch, D; Sachs, H; Szurman, P; Gülicher, D; Wilke, R; Reinert, S; Zrenner, E; Bartz-Schmidt, K U; Gekeler, F

    2008-10-01

    Due to low energy levels in microphotodiode-based subretinal visual prostheses, an external power supply is mandatory. We report on the surgical feasibility and the functional outcome of the extraocular part of an approach to connect a subretinal prosthesis to an extracorporeal connector in the retro-auricular space via a trans-scleral, transchoroidal cable. Seven volunteers with retinitis pigmentosa received an active subretinal implant; energy was supplied by gold wires on a trans-sclerally, transchoroidally implanted polyimide foil leading to the lateral orbital rim where it was fixated and connected to a silicone cable. The cable was implanted subperiostally beneath the temporal muscle using a trocar to the retro-auricular space where it penetrated the skin for connection to a stimulator. To avoid subretinal movement of the implant, three tension relief points have been introduced. All implantations were performed as planned without complications, and no serious adverse events occurred in the postoperative period. Fixation of the implants was stable throughout the entire study duration of 4 weeks; permanent skin penetration proved to be uncomplicated. Motility was minimally restricted in downgaze and ab-/adduction. Explantation was uneventful. The above-described procedure provides a method for stable fixation of a subretinal device with a trans-scleral, transchoroidal cable connection to an extracorporeal connector.

  5. Laparoscopic transumbilical gastrojejunostomy: an advanced anastomotic procedure performed through a single site.

    PubMed

    Nguyen, Ninh T; Slone, Johnathan; Reavis, Kevin M; Woolridge, James; Smith, Brian R; Chang, Ken

    2009-04-01

    Single-site laparoscopic surgery and natural orifice transumbilical surgery (NOTUS) have become exciting areas of surgical development. However, most reported case series consist of basic laparoscopic procedures, such as cholecystectomy and appendectomy. In this paper, we present the case of an advanced laparoscopic operation-construction of a gastrointestinal anastomosis-that was performed through ports placed entirely within the umbilicus. In this paper, we describe a 61-year-old male with a history of advanced pancreatic carcinoma who was referred with a gastric outlet obstruction. A laparoscopic gastrojejunostomy bypass, using a linear stapler with suture closure of the enterotomy, was performed through three abdominal trocars placed entirely within the umbilicus. Some potential advantages of NOTUS palliative gastrojejunostomy include reduced postoperative pain and the lack of visible abdominal scars. The operation was completed uneventfully in 40 minutes. The patient recovered without complications and was discharged on postoperative day 2. At 1-month follow-up, the patient had improved oral intake without any further vomiting symptoms. This case report documents the feasibility of an advanced anastomotic gastrojejunostomy procedure which can be performed through a single site. However, benefits of this approach, compared to conventional laparoscopic procedures, will require a prospective randomized clinical trial.

  6. Laparoscopy in patients following transverse rectus abdominis myocutaneous flap reconstruction.

    PubMed

    Muller, C Y; Coleman, R L; Adams, W P

    2000-07-01

    We report our technique and experience performing laparoscopic pelvic surgery on four women after transverse abdominus rectus myocutaneous flap (TRAM). Examination under anesthesia is performed on all patients in the low lithotomy position parallel with the floor. The abdominal aorta is palpated and outlined. A pneumoperitoneum is created either by umbilical or left upper quadrant Veress placement. Patients with an acceptable umbilical location undergo port placement through the incision of the umbilical relocation. Other options include left upper quadrant or paramedian placement avoiding the ligamentum teres vessels. Lateral operative ports (5 mm) are placed with reference to the transverse incision present, the pelvic pathology, and the location of the umbilicus. Techniques of electrocautery, intra- and extracorporeal suturing and knot tying, and clips are preferred to minimize port size. Following unilateral or bilateral TRAM reconstruction, four consecutive breast cancer survivors underwent successful laparoscopic-assisted vaginal hysterectomy with oophorectomy using the periumbilical incision for trocar placement. The only complication was a superficial skin breakdown from an adhesive allergy that required 6 weeks for complete resolution. Laparoscopic pelvic surgery is feasible in women after TRAM reconstruction. Knowledge of anatomic and physiologic variations related to the TRAM procedure is necessary in planning a safe operation.

  7. Initial laboratory experience with a novel ultrasound probe for standard and single-port robotic kidney surgery: increasing console surgeon autonomy and minimizing instrument clashing.

    PubMed

    Yakoubi, Rachid; Autorino, Riccardo; Laydner, Humberto; Guillotreau, Julien; White, Michael A; Hillyer, Shahab; Spana, Gregory; Khanna, Rakesh; Isaac, Wahib; Haber, Georges-Pascal; Stein, Robert J; Kaouk, Jihad H

    2012-06-01

    The aim of this study was to evaluate a novel ultrasound probe specifically developed for robotic surgery by determining its efficiency in identifying renal tumors. The study was carried out using the Da Vinci™ surgical system in one female pig. Renal tumor targets were created by percutaneous injection of a tumor mimic mixture. Single-port and standard robotic partial nephrectomy were performed. Intraoperative ultrasound was performed using both standard laparoscopic probe and the new ProART™ Robotic probe. Probe maneuverability and ease of handling for tumor localization were recorded. The standard laparoscopic probe was guided by the assistant. Significant clashing with robotic arms was noted during the single-port procedure. The novel robotic probe was easily introduced through the assistant trocar, and held by the console surgeon using the robotic Prograsp™ with no registered clashing in the external operative field. The average time for grasping the new robotic probe was less than 10 s. Once inserted and grasped, no limitation was found in terms of instrument clashing during the single-port procedure. This novel ultrasound probe developed for robotic surgery was noted to be user-friendly when performing porcine standard and especially single-port robotic partial nephrectomy. Copyright © 2011 John Wiley & Sons, Ltd.

  8. Cost variation in a laparoscopic cholecystectomy and the association with outcomes across a single health system: implications for standardization and improved resource utilization

    PubMed Central

    Brauer, David G; Hawkins, William G; Strasberg, Steven M; Brunt, L Michael; Jaques, David P; Mercurio, Nicholas R; Hall, Bruce L; Fields, Ryan C

    2015-01-01

    Background Payers and regulatory bodies are increasingly placing emphasis on cost containment, quality/outcome measurement and transparent reporting. Significant cost variation occurs in many operative procedures without a clear relationship with outcomes. Clear cost-benefit associations will be necessary to justify expenditures in the era of bundled payment structures. Methods All laparoscopic cholecystectomies (LCCKs) performed within a single health system over a 1-year period were analysed for operating room (OR) supply cost. The cost was correlated with American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) outcomes. Results From July 2013 to June 2014, 2178 LCCKs were performed by 55 surgeons at seven hospitals. The median case OR supply cost was $513 ± 156. There was variation in cost between individual surgeons and within an individual surgeon's practice. There was no correlation between cost and ACS NSQIP outcomes. The majority of cost variation was explained by selection of trocar and clip applier constructs. Conclusions Significant case OR cost variation is present in LCCK across a single health system, and there is no clear association between increased cost and NSQIP outcomes. Placed within the larger context of overall cost, the opportunity exists for improved resource utilization with no obvious risk for a reduction in the quality of care. PMID:26345351

  9. Novel technique for laparoscopic harvesting of latissimus dorsi flap with prosthesis implantation for breast reconstruction

    PubMed Central

    Xu, Shuman; Tang, Peng; Chen, Xianchun; Yang, Xi; Pan, Qinwen; Gui, Yu; Chen, Li

    2016-01-01

    Abstract Backgroud: An important drawback of the traditional technique for harvesting latissimus dorsi (LD) myocutaneous flap is a long, posterior donor-site incision. Current techniques involve endoscopic or robotic harvesting via a combined approach of open and closed surgery, which necessitates an open axillary incision and the use of special retractors. In this paper, we introduce a fully enclosed laparoscopic technique for harvesting LD flap (LDF) using only 3 small trocar ports. This technique eliminates the need for axillary and donor-site incisions and specialized retractors and considerably reduces the incision size. Methods: We performed laparoscopic harvesting of LDF with prosthesis implantation for immediate breast reconstruction (IBR) after nipple-sparing mastectomy in 2 patients with malignant breast neoplasm who wished to avoid a long scar on the back. Results: IBR using this technique was uneventful in both cases, without any donor-site complications or flap failure. Both patients were satisfied with the esthetic results of the procedure, especially the absence of a visible scar on the back. Conclusion: Enclosed laparoscopic harvesting of LDF is simpler and less invasive than the traditional methods. These preliminary results warrant further evaluation in a larger population to validate the benefits of this technique. PMID:27861385

  10. Innovative surgical endoscopes in video-assisted thoracic surgery

    PubMed Central

    Cheng, Truman; Ng, Calvin S. H.

    2018-01-01

    In the past three decades, rod lens endoscopes had facilitated the development and wide spread applications of video-assisted thoracic surgery (VATS). With the rise of uniportal VATS in recent years, innovations in surgical instruments should once again complement the advancement in surgical technique. While articulated flexible endoscopes have expand the field of view, and can alter viewing direction with minimal maneuvers, they still suffer from problems like trocar crowding and interference with other instruments. Magnetic anchored endoscopes, on the other hand, may provide unique benefits to VATS by replacing the endoscope rigid rod body with magnetic linkage, thus overcoming the challenge of port crowding in single incision surgery. Most magnetic anchored endoscopes reported in literature are not designed for thoracic surgeries. Many of these designs do not allow tilting of endoscopic view, rely on micromotors for actuation, or are ergonomically unfit to be operated within the spatial constraints seen in VATS application. Considering these limitations, we have designed two novel magnetic anchored and steered endoscopes targeted for uniportal VATS. Both designs could be wirelessly actuated by magnetic interaction. One has a silicone rubber formed soft body for compactness, lightweight and safety, while another is a 40 mm long capsule optimized for VATS spatial constraints. PMID:29732196

  11. Innovative surgical endoscopes in video-assisted thoracic surgery.

    PubMed

    Cheng, Truman; Ng, Calvin S H; Li, Zheng

    2018-04-01

    In the past three decades, rod lens endoscopes had facilitated the development and wide spread applications of video-assisted thoracic surgery (VATS). With the rise of uniportal VATS in recent years, innovations in surgical instruments should once again complement the advancement in surgical technique. While articulated flexible endoscopes have expand the field of view, and can alter viewing direction with minimal maneuvers, they still suffer from problems like trocar crowding and interference with other instruments. Magnetic anchored endoscopes, on the other hand, may provide unique benefits to VATS by replacing the endoscope rigid rod body with magnetic linkage, thus overcoming the challenge of port crowding in single incision surgery. Most magnetic anchored endoscopes reported in literature are not designed for thoracic surgeries. Many of these designs do not allow tilting of endoscopic view, rely on micromotors for actuation, or are ergonomically unfit to be operated within the spatial constraints seen in VATS application. Considering these limitations, we have designed two novel magnetic anchored and steered endoscopes targeted for uniportal VATS. Both designs could be wirelessly actuated by magnetic interaction. One has a silicone rubber formed soft body for compactness, lightweight and safety, while another is a 40 mm long capsule optimized for VATS spatial constraints.

  12. [Laparoscopic promontofixation technique].

    PubMed

    Mugnier, C; Gaston, R; Hoepffner, J L; Piéchaud, T

    2005-11-01

    Laparoscopic promontofixation often remains possible whatever the previous history of pelvic surgery, including the placing of prosthetic material. Preoperative care is standardized and is accompanied by antibiotic prophylaxis, preventive antithrombotic treatment and in the event of a history of pelvic surgery, a digestive preparation. Positioning of the patient must plan a 30 degrees Trendelenbourg position. After the introduction of trocars, initial surgery comprises interrectovaginal dissection to free the whole posterior surface of the vagina. This is followed by the installation of a posterior mesh pre-cut in an arch. The anterior face of the promontory is then freed after incision of the posterior peritoneum with the patient placed beforehand in a Trendelenbourg position. After intervesical vaginal dissection, the anterior prosthesis comprising a precut polyester mesh is fixed avoiding excess traction. The end of the surgery involves careful reperitonization of all the prosthetic parts. Possible specific surgical complications are vascular and visceral wounds. Postoperative secondary haemorrhage and gastrointestinal occlusion may occur. Occurrence of an inflammatory syndrome and low back pain suggests spondylodicitis and MRI should be performed. Vaginal erosion on the prosthesis (1.6 to 10% depending on the series) may occur after several months and seems relatively independent of the prosthetic material used.

  13. Microbiological evaluation of the steam sterilization of assembled laparoscopic instruments.

    PubMed

    Camargo, Tamara Carolina de; Graziano, Kazuko Uchikawa; Almeida, Alda Graciele Claudio Dos Santos; Suzuki, Karina; Silva, Cely Barreto da; Pinto, Flávia Morais Gomes

    2016-11-21

    assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination. a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator. Three of them were introduced into each instrument at the time of assembly, and sterilized at pressurized saturated steam, 134oC for 5 minutes. After sterilization, the instrument was disassembled and each filter paper substrate was inoculated in soybean casein culture and incubated at 56oC for 21 days. In case of absence of growth, they were subjected to heat shock of 80oC, for 20 minutes and re-incubated for 72 hours. Sample size: 185 graspers and 185 trocars, with 95% power. We paired the experiments with comparative negative control groups (5 graspers and 5 trocars with challenge contamination, sterilized disassembled) and positive control (30 filter paper supports, unsterilized), subject to the same incubation procedures. there was no microbial growth in experimental and negative control. The results of the positive control were satisfactory. this study provided strong scientific evidence to support the safety of steam sterilizing of the assembled laparoscopic instrument. avaliar a segurança da esterilização a vapor, do instrumental laparoscópico montado com desafio da contaminação. estudo experimental laboratorial, cujo corpo de prova foram trocarte e pinça laparoscópica. Utilizou-se esporos Geobacillus stearothermophillus ATCC-7953, com população microbiana de 106UFC/suporte de papel filtro, removidos do indicador biológico. Três deles foram introduzidos no interior de cada instrumento, no momento da montagem, sendo esterilizados a vapor saturado sob pressão, 134oC por 5 minutos. Depois da esterilização, o instrumental foi desmontado, e cada suporte de papel filtro foi inoculado em meio de cultura

  14. High-Speed Transport of Fluid Drops and Solid Particles via Surface Acoustic Waves

    NASA Technical Reports Server (NTRS)

    Bar-Cohen, Yoseph; Bao, Xiaoqi; Sherrit, Stewart; Badescu, Mircea; Lih, Shyh-shiuh

    2012-01-01

    A compact sampling tool mechanism that can operate at various temperatures, and transport and sieve particle sizes of powdered cuttings and soil grains with no moving parts, has been created using traveling surface acoustic waves (SAWs) that are emitted by an inter-digital transducer (IDT). The generated waves are driven at about 10 MHz, and it causes powder to move towards the IDT at high speed with different speeds for different sizes of particles, which enables these particles to be sieved. This design is based on the use of SAWs and their propelling effect on powder particles and fluids along the path of the waves. Generally, SAWs are elastic waves propagating in a shallow layer of about one wavelength beneath the surface of a solid substrate. To generate SAWs, a piezoelectric plate is used that is made of LiNbO3 crystal cut along the x-axis with rotation of 127.8 along the y-axis. On this plate are printed pairs of fingerlike electrodes in the form of a grating that are activated by subjecting the gap between the electrodes to electric field. This configuration of a surface wave transmitter is called IDT. The IDT that was used consists of 20 pairs of fingers with 0.4-mm spacing, a total length of 12.5 mm. The surface wave is produced by the nature of piezoelectric material to contract or expand when subjected to an electric field. Driving the IDT to generate wave at high amplitudes provides an actuation mechanism where the surface particles move elliptically, pulling powder particles on the surface toward the wavesource and pushing liquids in the opposite direction. This behavior allows the innovation to separate large particles and fluids that are mixed. Fluids are removed at speed (7.5 to 15 cm/s), enabling this innovation of acting as a bladeless wiper for raindrops. For the windshield design, the electrodes could be made transparent so that they do not disturb the driver or pilot. Multiple IDTs can be synchronized to transport water or powder over larger

  15. An Adhesive Patch-Based Skin Biopsy Device for Molecular Diagnostics and Skin Microbiome Studies.

    PubMed

    Yao, Zuxu; Moy, Ronald; Allen, Talisha; Jansen, Burkhard

    2017-10-01

    A number of diagnoses in clinical dermatology are currently histopathologically confirmed and this image recognition-based confirmation generally requires surgical biopsies. The increasing ability of molecular pathology to corroborate or correct a clinical diagnosis based on objective gene expression, mutation analysis, or molecular microbiome data is on the horizon and would be further supported by a tool or procedure to collect samples non-invasively. This study characterizes such a tool in form of a 'bladeless' adhesive patch-based skin biopsy device. The performance of this device was evaluated through a variety of complementary technologies including assessment of sample biomass, electron microscopy demonstrating the harvesting of layers of epidermal tissue, and isolation of RNA and DNA from epidermal skin samples. Samples were obtained by application of adhesive patches to the anatomical area of interest. Biomass assessment demonstrated collection of approximately 0.3mg of skin tissue per adhesive patch and electron microscopy confirmed the nature of the harvested epidermal skin tissue. The obtained tissue samples are stored in a stable fashion on adhesive patches over a wide range of temperatures (-80oC to +60oC) and for extended periods of time (7 days or more). Total human RNA, human genomic DNA and microbiome DNA yields were 23.35 + 15.75ng, 27.72 + 20.71ng and 576.2 + 376.8pg, respectively, in skin samples obtained from combining 4 full patches collected non-invasively from the forehead of healthy volunteers. The adhesive patch skin sampling procedure is well tolerated and provides robust means to obtain skin tissue, RNA, DNA, and microbiome samples without involving surgical biopsies. The non-invasively obtained skin samples can be shipped cost effectively at ambient temperature by mail or standard courier service, and are suitable for a variety of molecular analyses of the skin microbiome as well as of keratinocytes, T cells, dendritic cells

  16. Hanging Maneuver for Stomach Traction in Laparoscopic Distal Pancreatic Resections: An Original Technique Applied in 218 Patients.

    PubMed

    Dokmak, Safi; Aussilhou, Béatrice; Ftériche, Fadhel Samir; Belghiti, Jacques; Sauvanet, Alain

    2017-01-01

    Stomach traction done to expose the pancreas is still a problem in laparoscopic left pancreatic resections. We developed a simple hanging maneuver to retract the stomach rapidly and effectively. After dividing the gastrocolic ligament, the stomach was encircled with a tape, turned along its horizontal axis and pulled with an epigastric trocar, which was later removed. This technique was used in all patients who underwent laparoscopic left pancreatic resections including 165 distal pancreatectomies (DP), 35 central pancreatectomies (CP) and 18 enucleations (En). Demographics, surgical and postoperative outcome data were recorded. There were no mortalities. The mean operative time for DP, CP and En were 174, 191 and 104 min, respectively. The transfusion (0-4%) and conversion (0-3%) rates were low for all procedures. Morbidity was mainly represented by pancreatic fistula and grades (B + C) for DP, CP and En were observed in 26, 22 and 17%, respectively. No complication related to hanging of the stomach, like gastric perforation, was observed. Re-intervention and the mean hospital stay for DP, CP and En were observed in 5, 11 and 0% and were 16, 22 and 12, respectively. The readmission rate was low (0-9%). Hanging maneuver of the stomach is a simple procedure to rapidly, safely and effectively retract the stomach during left laparoscopic pancreatic resections. © 2016 S. Karger AG, Basel.

  17. History of power sources in endoscopic surgery.

    PubMed

    Sutton, Christopher; Abbott, Jason

    2013-01-01

    The history of energy sources used in surgery is inextricably linked to the history of electricity. Milestones include identification of safe electrical waveforms that can be used in the human body, patient isolation to prevent alternate-site burns, bipolar energy sources to negate capacitance injuries, laser energy, and the combination vessel sealing devices commonly used today. Engineering efforts to eliminate many of the hazards of electrosurgery are critical to how we practice modern gynecologic surgery. The introduction of bipolar instruments, increasing the safety of monopolar electrosurgery by not using hybrid trocars, and introduction of active shielding of the instruments from stray radiofrequency energy using intelligent secondary conductors have led to the re-emergence of electrosurgery as the universal surgical energy source. The low ongoing costs and the presence of electrosurgical generators in all hospitals readily enables electrosurgery to be the mainstay. Expensive lasers are confined to specialized centers, where they continue to be used, but for a long while filled a gap created by complications of electrosurgery. Sophisticated power sources continue to be introduced and include the ultrasonic scalpel, plasma surgery, and various devices for sealing vessels, all of which have advantages and disadvantages that are recognized as they begin to be subjected to scientific validation in randomized trials. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  18. Laparoscopy in the morbidly obese: physiologic considerations and surgical techniques to optimize success.

    PubMed

    Scheib, Stacey A; Tanner, Edward; Green, Isabel C; Fader, Amanda N

    2014-01-01

    The objectives of this review were to analyze the literature describing the benefits of minimally invasive gynecologic surgery in obese women, to examine the physiologic considerations associated with obesity, and to describe surgical techniques that will enable surgeons to perform laparoscopy and robotic surgery successfully in obese patients. The Medline database was reviewed for all articles published in the English language between 1993 and 2013 containing the search terms "gynecologic laparoscopy" "laparoscopy," "minimally invasive surgery and obesity," "obesity," and "robotic surgery." The incidence of obesity is increasing in the United States, and in particular morbid obesity in women. Obesity is associated with a wide range of comorbid conditions that may affect perioperative outcomes including hypertension, atherosclerosis, angina, obstructive sleep apnea, and diabetes mellitus. In obese patients, laparoscopy or robotic surgery, compared with laparotomy, is associated with a shorter hospital stay, less postoperative pain, and fewer wound complications. Specific intra-abdominal access and trocar positioning techniques, as well as anesthetic maneuvers, improve the likelihood of success of laparoscopy in women with central adiposity. Performing gynecologic laparoscopy in the morbidly obese is no longer rare. Increases in the heaviest weight categories involve changes in clinical practice patterns. With comprehensive and thoughtful preoperative and surgical planning, minimally invasive gynecologic surgery may be performed safely and is of particular benefit in obese patients. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  19. Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Qing-Hua, E-mail: ddqinghua-tian@163.com; He, Cheng-Jian, E-mail: tianhechengjian@163.com; Wu, Chun-Gen, E-mail: 649514608@qq.com

    PurposeTo compare the efficacy of percutaneous cementoplasty (PCP) with and without interventional internal fixation (IIF) on malignant impending pathological fracture of proximal femur.MethodsA total of 40 patients with malignant impending pathological fracture of proximal femur were selected for PCP and IIF (n = 19, group A) or PCP alone (n = 21, group B) in this non-randomized prospective study. Bone puncture needles were inserted into the proximal femur, followed by sequential installation of the modified trocar inner needles through the puncture needle sheath. Then, 15–45 ml cement was injected into the femur lesion.ResultsThe overall excellent and good pain relief rate during follow-ups were significantly highermore » in group A than that in group B (89 vs. 57 %, P = 0.034). The average change of VAS, ODI, KPS, and EFES in group A were significantly higher than those in group B at 1-, 3-, 6-month, 1-year (P < 0.05). Meanwhile, The stability of the treated femur was significantly higher in group A than that in group B (P < 0.05).ConclusionPCP and IIF were not only a safe and effective procedure, but resulted in greater pain relief, bone consolidation, and also reduced the risk of fracture than the currently recommended approach of PCP done on malignant proximal femoral tumor.« less

  20. Single port radical prostatectomy: current status.

    PubMed

    Martín, Oscar Darío; Azhar, Raed A; Clavijo, Rafael; Gidelman, Camilo; Medina, Luis; Troche, Nelson Ramirez; Brunacci, Leonardo; Sotelo, René

    2016-06-01

    The aim of this study is to analyze the current literature on single port radical prostatectomy (LESS-RP). Single port radical prostatectomy laparoendoscopic (LESS-RP) has established itself as a challenge for urological community, starting with the proposal of different approaches: extraperitoneal, transperitoneal and transvesical, initially described for laparoscopy and then laparoscopy robot-assisted. In order to improve the LESS-RP, new instruments, optical devices, trocars and retraction mechanisms have been developed. Advantages and disadvantages of LESS-RP are controversial, while some claim that it is a non-trustable approach, regarding the low cases number and technical difficulties, others acclaim that despite this facts some advantages have been shown and that previous described difficulties are being overcome, proving this is novel proposal of robotics platform, the Da Vinci SP, integrating the system into "Y". The LESS-RP approach gives us a new horizon and opens the door for rapid standardization of this technique. The few studies and short series available can be result of a low interest in the application of LESS-RP in prostate, probably because of the technical complexity that it requires. The new robotic platform, the da Vinci SP, shows that it is clear that the long awaited evolution of robotic technologies for laparoscopy has begun, and we must not lose this momentum.

  1. Safety and Efficacy of Single Incision Laparoscopic Surgery for Total Extraperitoneal Inguinal Hernia Repair

    PubMed Central

    2011-01-01

    Almost 20 years after the first laparoscopic inguinal hernia repair was performed, single incision laparoscopic surgery (SILS™) is set to revolutionize minimally invasive surgery. However, the loss of triangulation must be overcome before the technique can be popularized. This study reports the first 100 laparoscopic total extraperitoneal hernia repairs using a single incision. The study cohort comprised 68 patients with a mean age of 44 (range, 18 to 83): 36 unilateral and 32 bilateral hernias. Twelve patients also underwent umbilical hernia repair with the Ventralex patch requiring no additional incisions. A 2.5-cm to 3-cm crescentic incision within the confines of the umbilicus was performed. Standard dissecting instruments and 52-cm/5.5-mm/300 laparoscope were used. Operation times were 50 minutes for unilateral and 80 minutes for bilateral. There was one conversion to conventional 3-port laparoscopic repair and none to open surgery. Outpatient surgery was achieved in all (except one). Analgesic requirements were minimal: 8 Dextropropoxyphene tablets (range, 0 to 20). There were no intraoperative or postoperative complications with a high patient satisfaction score. Single-incision laparoscopic hernia repair is safe and efficient simply by modifying dissection techniques (so-called “inline” and “vertical”). Comparable success can be obtained while negating the risks of bowel and vascular injuries from sharp trocars and achieving improved cosmetic results. PMID:21902942

  2. Incidence of Port-Site Incisional Hernia After Single-Incision Laparoscopic Surgery

    PubMed Central

    Rainville, Harvey; Ikedilo, Ojinika; Vemulapali, Pratibha

    2014-01-01

    Background and Objectives: Single-incision laparoscopic surgery is gaining popularity among minimally invasive surgeons and is now being applied to a broad number of surgical procedures. Although this technique uses only 1 port, the diameter of the incision is larger than in standard laparoscopic surgery. The long-term incidence of port-site hernias after single-incision laparoscopic surgery has yet to be determined. Methods: All patients who underwent a single-incision laparoscopic surgical procedure from May 2008 through May 2009 were included in the study. Single-incision laparoscopic surgical operations were performed either by a multiport technique or with a 3-trocar single-incision laparoscopic surgery port. The patients were seen at 30 to 36 months' follow-up, at which time they were examined for any evidence of port-site incisional hernia. Patients found to have hernias on clinical examination underwent repairs with mesh. Results: A total of 211 patients met the criteria for inclusion in the study. The types of operations included were cholecystectomy, appendectomy, sleeve gastrectomy, gastric banding, Nissen fundoplication, colectomy, and gastrojejunostomy. We found a port-site hernia rate of 2.9% at 30 to 36 months' follow-up. Conclusion: Port-site incisional hernia after single-incision laparoscopic surgical procedures remains a major setback for patients. The true incidence remains largely unknown because most patients are asymptomatic and therefore do not seek surgical aid. PMID:24960483

  3. A new minimally invasive heart surgery instrument for atrial fibrillation treatment: first in vitro and animal tests.

    PubMed

    Abadie, J; Faure, A; Chaillet, N; Rougeot, P; Beaufort, D; Goldstein, J P; Finlay, P A; Bogaerts, G

    2006-06-01

    The paper presents a new robotic system for beating heart surgery. The final goal of this project is to develop a tele-operated system for the thoracoscopic treatment of patients with atrial fibrillation. The system consists of a robot that moves an innovative end-effector used to perform lines as in the Cox-Maze technique. The device is an electrode mesh that is introduced in the thorax through a trocar and is deployed inside the left atrium, where it can create selective ablation lines at any atrial region, using radio frequency. The current version of the umbrella has 22 electrodes. Using visual feedback from an ultrasound based navigation system, the surgeon can choose which electrodes on the mesh to activate. Once the umbrella is in contact with the endocardium of the left atrium, at the expected position, the surgeon activates the chosen electrodes sequentially. The umbrella can then be moved to another position. In vitro and in vivo animal tests have been carried out in order to test and improve the instrument, the robotic system and the operative procedure. The performed trials proved the ability of the system to treat atrial fibrillation. More in vivo tests are currently being performed to make the robot and its device ready for clinical use. Copyright 2006 John Wiley & Sons, Ltd.

  4. Laparoendoscopic single site surgery in pediatric urology: does it require specialized tools?

    PubMed Central

    Patel, Nishant; Santomauro, Michael; Marietti, Sarah; Chiang, George

    2016-01-01

    ABSTRACT Purpose: To describe our experience utilizing Laparoendoscopic single site (LESS) surgery in pediatric urology. Materials and Methods: Retrospective chart review was performed on LESS urologic procedures from November 2009 through March 2013. A total of 44 patients underwent 54 procedures including: nephrectomy (23), orchiopexy (14), varicocelectomy (9), orchiectomy (2), urachal cyst excision (3), and antegrade continence enema (3) (ACE). Results: Median patient age was 6.9 years old. Estimated blood loss (EBL), ranged from less than 5cc to 47cc for a bilateral nephrectomy. Operative time varied from 56 mins for varicocelectomy to a median of 360 minutes for a bilateral nephroureterectomy. Incision length ranged between 2 and 2.5cm. In our initial experience we used a commercial port. However, as we progressed, we were able to perform the majority of our procedures via adjacent fascial punctures for instrumentation at the single incision site. One patient did require conversion to an open procedure as a result of bleeding. Three complications were noted (6.8%), with two Clavien Grade 3b complications. Two patients required additional procedures at 1-year follow-up. Conclusions: The use of LESS applies to many pediatric urologic procedures, ideally for ablative procedures or simple reconstructive efforts. The use of adjacent fascial puncture sites for instrumentation can obviate the need for a commercial port or multiple trocars. PMID:27256182

  5. Combination of external beam irradiation and multiple-site perineal applicator (MUPIT) for treatment of locally advanced or recurrent prostatic, anorectal, and gynecologic malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez, A.; Edmundson, G.K.; Cox, R.S.

    1985-02-01

    The authors have devised a single after-loading applicator, the Martinez Universal Perineal Interstitital Template (MUPIT), which has been used in combination with external beam irradiation to treat 104 patients with either locally advanced or recurrent malignancies of the cervix, vagina, female uretha, prostate, or anorectal region. Twenty-six patients treated for prostate cancer are excluded because of their short follow-up. Local failure developed in 13 of the 78 remaining patients (16.6%) - major complications developed in 4 patients (5.1%). All local recurrences and complications occurred before 18 months. The device consists of two acrylic cyclinders, an acrylic template with an arraymore » of holes that serve as guides for trocars, and a cover plate. In use, the cylinders are placed in the vagina and/or rectum or both and then fastened to the template so that a fixed geometric relationship among the tumor volume, normal structures, and source placement is preserved throughout the course of the implantation. Appropriate computer programs have been developed to calculate the dose from these implants. They conclude that the local control rate (83.4%) with low morbidity (5.1%) achieved with the combination of external beam irradiation and MUPIT applicator in these patients with locally advanced malignancies represents an improvement over previous published results with other applicators.« less

  6. Novel Surgical Treatments for Gastroesophageal Reflux Disease: Systematic Review of Magnetic Sphincter Augmentation and Electric Stimulation Therapy

    PubMed Central

    Stanak, Michal; Erdos, Judit; Hawlik, Katharina; Birsan, Tudor

    2018-01-01

    Electric stimulation therapy (EST) and magnetic sphincter augmentation (MSA) represent novel methods for the surgical treatment of gastroesophageal reflux disease (GERD). The aim of this review was to assess the effectiveness and safety of EST and magnetic sphincter augmentation device (MSAD) comapred to laparoscopic fundoplication (LF) and proton pump inhibitor therapy (in case of EST). We performed a systematic literature search without restrictions on publication dates in five electronic databases (MEDLINE, EMBASE, the Cochrane library, PubMed, and Centre for Reviews and Dissemination), complemented by hand search, search in trial registries, and documentation provided by the manufacturers. No study passed inclusion criteria for analyzing EST effectiveness. Concerning safety, lead erosion through the esophagus and trocar perforation of the small bowel occurred in 2.4% of patients (in one study). Only the registry study fulfilled inclusion criteria for effectiveness analysis of MSAD. The crucial outcome of GERD-health-related quality of life (HRQL) score improved from 20 to 3 points in MSAD patients, and from 23 to 3.5 points in LF patients. However, the LF patients were in a more severe stage of the disease. The results yield indefinite conclusions about the use of both MSAD and EST. Clinical effectiveness and safety of both MSAD and EST are not sufficiently proven and are yet to be supported by high quality evidence from randomized controlled trials.

  7. Laparoscopic Management of Hepatic Hydatid Disease

    PubMed Central

    Palanivelu, C; Malladi, Vijaykumar; Senthilkumar, R.; Rajan, P. S.; Sendhilkumar, K.; Parthasarthi, R.; Kavalakat, Alfie

    2006-01-01

    Background: Hydatid disease is an endemic condition in several parts of the world. Owing to ease of travel, even surgeons in nonendemic areas encounter the disease and should be aware of its optimum treatment. A safe, new method of laparoscopic management of hepatic hydatid disease is described along with a review of the relevant literature. Methods: Sixty-six cases of hepatic hydatid disease were operated on laparoscopically using the Palanivelu Hydatid System. The special trocar-cannula system used and the technique of operation are described. Results: The majority of the patients presented with pain. Most of the patients had only a single cyst. The right lobe of the liver was most commonly involved. Cysts were bilateral in 4 patients. In 83.3%, simply evacuation of the hydatid cyst by the Palanivelu Hydatid System was done. In 13.7%, this was followed by a left lobectomy, as the cysts were large occupying almost the entire left lobe of the liver. The remnant cavity was dealt with by omentoplasty. The average follow-up period is 5.8 years. There have been no recurrences to date. Conclusion: We recommend Palanivelu Hydatid System for management of hepatic hydatid disease. We have found its efficacy to be optimum for preventing spillage, evacuating hydatid cyst contents, performing transcystic fenestration, and for dealing with cyst-biliary communications. PMID:16709359

  8. Laparoscopic management of hepatic hydatid disease.

    PubMed

    Palanivelu, C; Jani, Kalpesh; Malladi, Vijaykumar; Senthilkumar, R; Rajan, P S; Sendhilkumar, K; Parthasarthi, R; Kavalakat, Alfie

    2006-01-01

    Hydatid disease is an endemic condition in several parts of the world. Owing to ease of travel, even surgeons in nonendemic areas encounter the disease and should be aware of its optimum treatment. A safe, new method of laparoscopic management of hepatic hydatid disease is described along with a review of the relevant literature. Sixty-six cases of hepatic hydatid disease were operated on laparoscopically using the Palanivelu Hydatid System. The special trocar-cannula system used and the technique of operation are described. The majority of the patients presented with pain. Most of the patients had only a single cyst. The right lobe of the liver was most commonly involved. Cysts were bilateral in 4 patients. In 83.3%, simply evacuation of the hydatid cyst by the Palanivelu Hydatid System was done. In 13.7%, this was followed by a left lobectomy, as the cysts were large occupying almost the entire left lobe of the liver. The remnant cavity was dealt with by omentoplasty. The average follow-up period is 5.8 years. There have been no recurrences to date. We recommend Palanivelu Hydatid System for management of hepatic hydatid disease. We have found its efficacy to be optimum for preventing spillage, evacuating hydatid cyst contents, performing transcystic fenestration, and for dealing with cyst-biliary communications.

  9. Preliminary application of a single-port access technique for laparoscopic ovariohysterectomy in dogs

    PubMed Central

    Sánchez-Margallo, F. M.; Tapia-Araya, A.; Díaz-Güemes, I.

    2015-01-01

    Laparoscopic ovariohysterectomy using single-portal access was performed in nine selected owned dogs admitted for elective ovariohysterectomy and the surgical technique and outcomes were detailed. A multiport device (SILS Port, Covidien, USA) was placed at the umbilical area through a single 3 cm incision. Three cannulae were introduced in the multiport device through the access channels and laparoscopic ovariohysterectomy was performed using a 5-mm sealing device, a 5-mm articulating grasper and a 5-mm 30° laparoscope. The mean total operative time was 52.66±15.20 minutes and the mean skin incision during surgery was 3.09±0.20 cm. Of the nine cases examined, in the one with an ovarian tumour, the technique was converted to multiport laparoscopy introducing an additional 5-mm trocar. No surgical complications were encountered and intraoperative blood loss was minimum in all animals. Clashing of the instruments and reduced triangulation were the main limitations of this technique. The combination of articulated and straight instruments facilitated triangulation towards the surgical field and dissection capability. One month after surgery a complete wound healing was observed in all animals. The present data showed that ovariohysterectomy performed with a single-port access is technically feasible in dogs. The unique abdominal incision minimises the abdominal trauma with good cosmetic results. PMID:26568831

  10. AdVance male sling

    PubMed Central

    Chung, Amanda S. J.; Suarez, Oscar A.

    2017-01-01

    The AdVance sling (American Medical Systems, Minnetonka, MN, United States of America) is a synthetic transobturator sling, which is a safe and effective minimally invasive treatment for mild to moderate stress urinary incontinence (SUI) in male patients. This article provides a step-by-step description of our technique for placement of the AdVance male sling, including details and nuances gained from surgical experience, advice for avoidance of complications and discussion on management of complications and sling failures. Patient selection is very important, including exclusion and preoperative treatment of urethral stenosis and bladder dysfunction. Previous pelvic radiation is a poor prognostic factor. In brief, the steps of sling placement are: (I) mobilization of the corpus spongiosum (CS); (II) marking and mobilization of the central tendon; (III) passage of the helical trocar needles exiting at the apex of the angle between the CS and inferior pubic ramus; (IV) fixation of the broad part of the sling body to the CS at the previous mark; (V) cystoscopy during sling tensioning; (VI) placement of a Foley urethral catheter; (VII) Subcutaneous tunnelling of the sling arms back toward the midline; (VIII) wound closure. The most common early postoperative complication is urinary retention but long-term retention is extremely rare. Management of sling failures include placement of an artificial urinary sphincter, repeat AdVance sling, urethral bulking agent or ProACT device. PMID:28904900

  11. Tool Helps Utilities Assess Readiness for Electric Vehicle Charging (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    NREL research helps answer a fundamental question regarding electric vehicles: Is the grid ready to handle them? Environmental, economic and security concerns regarding oil consumption make electrifying the transportation sector a high national priority. NREL's Center for Transportation Technologies & Systems (CTTS) has developed a framework for utilities to evaluate the plug-in vehicle (PEV) readiness of distribution transformers. Combining a wealth of vehicle performance statistics with load data from partner utilities including the Hawaiian Electric Company and Xcel Energy, NREL analyzed the thermal loading characteristics of distribution transformers due to vehicle charging. After running millions of simulations replicating varying climatesmore » and conditions, NREL is now able to predict aging rates for transformers when PEVs are added to existing building loads. With the NREL tool, users define simulation parameters by inputting vehicle trip and weather data; transformer load profiles and ratings; PEV penetration, charging rates and battery sizes; utility rates; the number of houses on each transformer; and public charging availability. Transformer load profiles, drive cycles, and ambient temperature data are then run through the thermal model to produce a one-year timeseries of the hotspot temperature. Annual temperature durations are calculated to help determine the annual aging rate. Annual aging rate results are grouped by independent variables. The most useful measure is transformer mileage, a measure of how many electrically-driven miles must be supplied by the transformer. Once the spectrum analysis has been conducted for an area or utility, the outputs can be used to help determine if more detailed evaluation is necessary, or if transformer replacement is required. In the majority of scenarios, transformers have enough excess capacity to charge PEVs. Only in extreme cases does vehicle charging have negative long-term impact on transformers. In

  12. Does the surgical approach for treating mandibular condylar fractures affect the rate of seventh cranial nerve injuries? A systematic review and meta-analysis based on a new classification for surgical approaches.

    PubMed

    Al-Moraissi, Essam Ahmed; Louvrier, Aurélien; Colletti, Giacomo; Wolford, Larry M; Biglioli, Federico; Ragaey, Marwa; Meyer, Christophe; Ellis, Edward

    2018-03-01

    The purpose of this study was to determine the rate of facial nerve injury (FNI) when performing (ORIF) of mandibular condylar fractures by different surgical approaches. A systematic review and meta-analysis were performed that included several databases with specific keywords, a reference search, and a manual search for suitable articles. The inclusion criteria were all clinical trials, with the aim of assessing the rate of facial nerve injuries when (ORIF) of mandibular condylar fractures was performed using different surgical approaches. The main outcome variable was transient facial nerve injury (TFNI) and permanent facial nerve injury (PFNI) according to the fracture levels, namely: condylar head fractures (CHFs), condylar neck fractures (CNFs), and condylar base fractures (CBFs). For studies where there was no delineation between CNFs and CBFs, the fractures were defined as CNFs/CBFs. The dependent variables were the surgical approaches. A total of 3873 patients enrolled in 96 studies were included in this analysis. TFNI rates reported in the literature were as follows: A) For the transoral approach: a) for strictly intraoral 0.72% (1.3 in CNFs and 0% for CBFs); b) for the transbuccal trocar instrumentation 2.7% (4.2% in CNFs and 0% for CBFs); and c) for endoscopically assisted ORIF 4.2% (5% in CNFs, and 4% in CBFs). B) For low submandibular approach 15.3% (26.1% for CNFs, 11.8% for CBFs, and 13.7% for CNFs/CBFs). C) For the high submandibular/angular subparotid approach with masseter transection 0% in CBFs. D) For the high submandibular/angular transmassetric anteroparotid approach 0% (CNFs and CBFs). E) For the transparotid retromandibular approach a) with nerve facial preparation 14.4% (23.9% in CNFs, 11.8% in CBFs and 13.7% for CNFs/CBFs); b) without facial nerve preparation 19% (24.3% for CNFs and 10.5% for CBFs). F) For retromandibular transmassetric anteroparotid approach 3.4% in CNFs/CBFs. G) For retromandibular transmassetric anteroparotid

  13. Vitreous humor thermodynamics during phacoemulsification.

    PubMed

    Salcedo-Villanueva, Guillermo; Kon-Jara, Veronica; Harasawa, Mariana; Cervantes-Coste, Guadalupe; Ochoa-Contreras, Daniel; Morales-Cantón, Virgilio; Guerrero-Naranjo, José Luis; Quiroz-Mercado, Hugo; Landers, Maurice B

    2015-08-01

    The purpose of this study is to determine baseline vitreous humor temperature during a combined phacoemulsification and pars plana vitrectomy (PPV) procedure; to determine what is the temperature variation during phacoemulsification; and to compare vitreous temperature to sublingual temperature. The methods used are prospective, interventional and comparative study. Patients with a diagnosis of cataract and vitreous hemorrhage, programed for a combined procedure of phacoemulsification and PPV, were included. Patients were excluded if posterior capsular rupture existed during the anterior segment procedure. A thermoprobe was inserted through a PPV trocar. Measurement of the vitreous temperature was obtained at baseline and throughout phacoemulsification, at the end of every surgical step, and every 5 min. Sublingual temperature was measured with the same probe at the end of the surgery. Room temperature was registered. Seventeen eyes of 17 patients were included. Mean sublingual temperature was 36.5 °C (standard deviation [σ] 0.26 °C). Mean total vitreous temperature was 31.47 °C (σ 2.1 °C). Mean baseline vitreous temperature was 33.04 °C (σ 0.99 °C). Comparison of sublingual temperature with baseline vitreous temperature resulted in a significant difference (t test P < 0.000. 95 % confidence interval 2.93-3.98). Temperature measured by surgical step and surgical time presented a significant decrease in temperature from baseline (Kruskal-Wallis P < 0.000, P = 0.003, respectively). Vitreous humor is significantly hypothermic when compared to sublingual temperature. Vitreous temperature decreases significantly during phacoemulsification.

  14. [Prosthetic bilateral laparoscopic hernioplasty. Extra-peritoneal approach].

    PubMed

    Rossi, M; Castoro, C; Zaninotto, G; Comandella, M G; Polo, R; Nolli, M L; Ancona, E

    1997-03-01

    The use of prosthetic mesh in inguinal hernia repairs is becoming increasingly popular. In recent years different laparoscopic procedures for prosthetic repair of inguinal hernias have been developed. The authors describe their initial experience with a totally extra-peritoneal prosthetic approach in laparoscopic repair of bilateral inguinal hernias. From November 1993 to May 1994, ten consecutive patients with bilateral primary inguinal hernias underwent laparoscopic repair under general anesthesia. A totally extra-peritoneal approach has been performed beginning through a 2 centimeter vertical midline sub-umbilical incision. Two additional trocars have been inserted on the midline: a 10/12 mm one halfway between the umbilicus and the pubis and 5 mm one 2 cm above the pubis. Average operative time was 141 minutes. Two cases were converted to traditional open Stoppa procedure because of holes made in the peritoneum during blunt dissection of the hernia sac. In the remaining 8 cases a polypropylene mesh of about 8 cm in height and 13 cm in length have been placed on each hernia site. No major complications have been observed and recovery was quick in all cases. In conclusion we think that laparoscopic hernia repair through a totally extra-peritoneal approach is technically feasible for general surgeons trained in laparoscopic surgery. Nevertheless the operation in costly and the patient's benefit in terms of rapid recovery, complications and recurrences has not yet been demonstrated in controlled prospective trials.

  15. Initial experience with purely laparoscopic living-donor right hepatectomy.

    PubMed

    Hong, S K; Lee, K W; Choi, Y; Kim, H S; Ahn, S W; Yoon, K C; Kim, H; Yi, N J; Suh, K S

    2018-05-01

    There may be concerns about purely laparoscopic donor right hepatectomy (PLDRH) compared with open donor right hepatectomy, especially when performed by surgeons accustomed to open surgery. This study aimed to describe technical tips and pitfalls in PLDRH. Data from donors who underwent PLDRH at Seoul National University Hospital between December 2015 and July 2017 were analysed retrospectively. Endpoints analysed included intraoperative events and postoperative complications. All operations were performed by a single surgeon with considerable experience in open living donor hepatectomy. A total of 26 donors underwent purely laparoscopic right hepatectomy in the study interval. No donor required transfusion during surgery, whereas two underwent reoperation. In two donors, the dissection plane at the right upper deep portion of the midplane was not correct. One donor experienced portal vein injury during caudate lobe transection, and one developed remnant left hepatic duct stenosis. One donor experienced remnant portal vein angulation owing to a different approach angle, and one experienced arterial damage associated with the use of a laparoscopic energy device. One donor had postoperative bleeding due to masking of potential bleeding foci owing to intra-abdominal pressure during laparoscopy. Two donors experienced right liver surface damage caused by a xiphoid trocar. Purely laparoscopic donor hepatectomy differs from open donor hepatectomy in terms of angle and caudal view. Therefore, surgeons experienced in open donor hepatectomy must gain adequate experience in laparoscopic liver surgery and make adjustments when performing PLDRH. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  16. Health risk to medical personnel of surgical smoke produced during laparoscopic surgery.

    PubMed

    Dobrogowski, Miłosz; Wesolowski, Wiktor; Kucharska, Małgorzata; Paduszyńska, Katarzyna; Dworzyńska, Agnieszka; Szymczak, Wiesław; Sapota, Andrzej; Pomorski, Lech

    2015-01-01

    During laparoscopic cholecystectomy, the removal of the gall bladder, pyrolysis occurs in the peritoneal cavity. Chemical substances which are formed during this process escape into the operating room through trocars in the form of surgical smoke. The aim of this study was to identify and quantitatively measure a number of selected chemical substances found in surgical smoke and to assess the risk they carry to medical personnel. The study was performed at the Maria Skłodowska-Curie Memorial Provincial Specialist Hospital in Zgierz between 2011 and 2013. Air samples were collected in the operating room during laparoscopic cholecystectomy. A complete qualitative and quantitative analysis of the air samples showed a number of chemical substances present, such as aldehydes, benzene, toluene, ethylbenzene, xylene, ozone, dioxins and others. The concentrations of these substances were much lower than the hygienic standards allowed by the European Union Maximum Acceptable Concentration (MAC). The calculated risk of developing cancer as a result of exposure to surgical smoke during laparoscopic cholecystectomy is negligible. Yet it should be kept in mind that repeated exposure to a cocktail of these substances increases the possibility of developing adverse effects. Many of these compounds are toxic, and may possibly be carcinogenic, mutagenic or genotoxic. Therefore, it is necessary to remove surgical smoke from the operating room in order to protect medical personnel. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  17. Mechanical simulators for training for laparoscopic surgery in urology.

    PubMed

    Rassweiler, Jens; Klein, Jan; Teber, Dogu; Schulze, Michael; Frede, Thomas

    2007-03-01

    The introduction of laparoscopic surgery into urology has led to new training concepts differing significantly from previous concepts of training for open surgery. This paper focuses on the type and importance of mechanical simulators in laparoscopic training. On the basis of our own studies and experience with the development of various concepts of laparoscopic training, including different modules (i.e., Pelvi-trainer, animal models, clinical mentoring) since 1991, we reviewed the current literature concerning all types of simulators. We focused on training for laparoscopic ablative and reconstructive surgery using mechanical simulators. The principle of a mechanical simulator (i.e., a box with the possibility of trocar insertion) has not changed during the last decade. However, the types of Pelvi-trainers and the models used inside have been improved significantly. According to the task of the simulator, various sophisticated models have been developed, including standardized phantoms, animal organs, and even perfused segments of porcine organs. For laparoscopic suturing, various step-by-step training concepts have been presented. These can be used for determination of the ability of a physician with an interest in laparoscopic surgery, but also to classify the training status of a laparosopic surgeon. Training in laparoscopic surgery has become an important topic, not only in learning a procedure, but also in maintaining skills and preparing for the management of complications. For these purposes, mechanical simulators will definitely play an important role in the future.

  18. Forty-five-degree or higher insertion angles are required to penetrate the opposite cortex in bicortical applications of Kirschner wires: an in vitro study on sheep bones.

    PubMed

    Colak, Mehmet; Gurer, Burak; Sungur, Mehmet Ali; Eskandari, Metin Manouchehr

    2012-04-01

    Slippage of the wires over the opposite cortex from the endosteal side is frequent and can lead to insufficient stability. This in vitro biomechanical study was planned to investigate the angle of wire insertion that leads to trans cortex perforation. Long bones of sheep were cut longitudinally into two pieces and half bones were stabilised on a frame. Three orthopaedic surgeons performed the experiment using ten wires of four different diameters at two different drilling speeds. Each wire was introduced from the endosteal side at angles starting at 30° in 5° increments until perforation. When perforation was achieved, the angle was recorded. To determinate the critical angle of perforation, receiver operating characteristic (ROC) curve analyses was performed. Two-way factorial analysis of variance (ANOVA) and Kruskal-Wallis tests were used for statistical comparisons. Kirschner-wire insertion angles of ≥ 45° provided perforation with a percentage of 83.9 %. Wire diameter, drilling speed and surgeon variables had no effect on perforation angles (p > 0.05). If preoperative evaluation of fractures to be fixed by K wires reveals the need for oblique wire insertion angle < 45°, a standard trocar-tip K wire application would lead to slippage of the wire tip on the endosteal surface of the opposite cortex. According to this study, the operative plan should be changed if such obliquity of the K wire is mandatory during bicortical applications.

  19. Visually guided tube thoracostomy insertion comparison to standard of care in a large animal model.

    PubMed

    Hernandez, Matthew C; Vogelsang, David; Anderson, Jeff R; Thiels, Cornelius A; Beilman, Gregory; Zielinski, Martin D; Aho, Johnathon M

    2017-04-01

    Tube thoracostomy (TT) is a lifesaving procedure for a variety of thoracic pathologies. The most commonly utilized method for placement involves open dissection and blind insertion. Image guided placement is commonly utilized but is limited by an inability to see distal placement location. Unfortunately, TT is not without complications. We aim to demonstrate the feasibility of a disposable device to allow for visually directed TT placement compared to the standard of care in a large animal model. Three swine were sequentially orotracheally intubated and anesthetized. TT was conducted utilizing a novel visualization device, tube thoracostomy visual trocar (TTVT) and standard of care (open technique). Position of the TT in the chest cavity were recorded using direct thoracoscopic inspection and radiographic imaging with the operator blinded to results. Complications were evaluated using a validated complication grading system. Standard descriptive statistical analyses were performed. Thirty TT were placed, 15 using TTVT technique, 15 using standard of care open technique. All of the TT placed using TTVT were without complication and in optimal position. Conversely, 27% of TT placed using standard of care open technique resulted in complications. Necropsy revealed no injury to intrathoracic organs. Visual directed TT placement using TTVT is feasible and non-inferior to the standard of care in a large animal model. This improvement in instrumentation has the potential to greatly improve the safety of TT. Further study in humans is required. Therapeutic Level II. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Does Preincisional Infiltration with Bupivacaine Reduce Postoperative Pain in Laparoscopic Bariatric Surgery?

    PubMed

    Moncada, Rafael; Martinaitis, Linas; Landecho, Manuel; Rotellar, Fernando; Sanchez-Justicia, Carlos; Bellver, Manuel; de la Higuera, Magdalena; Silva, Camilo; Osés, Beatriz; Martín, Elena; Pérez, Susana; Hernandez-Lizoain, Jose Luis; Frühbeck, Gema; Valentí, Victor

    2016-02-01

    Current evidence suggests that local anesthetic wound infiltration should be employed as part of multimodal postoperative pain management. There is scarce data concerning the benefits of this anesthetic modality in laparoscopic weight loss surgery. Therefore, we analyzed the influence of trocar site infiltration with bupivacaine on the management of postoperative pain in laparoscopic bariatric surgery. This retrospective randomized study included 47 patients undergoing primary obesity surgery between January and September 2014. Laparoscopic gastric bypass was performed in 39 cases and sleeve gastrectomy in 8 cases. Patients were stratified into two groups depending on whether preincisional infiltration with bupivacaine and epinephrine was performed (study group, 27 patients) or not (control group, 20 patients). Visual analogue scale (VAS), International Pain Outcomes questionnaire, and rescue medication records were reviewed to assess postoperative pain. VAS scores in the study group and sleeve gastrectomy group were lower than those in the control and gastric bypass groups in the first 4 h postoperatively without reaching statistical significance (p > 0.05). VAS scores did not differ in any other period of time. No statistically significant differences in pain perception were registered according to the patient's pain outcomes questionnaire or the need for rescue medication. The present study did not conclusively prove the efficacy of bupivacaine infiltration by any of the three evaluation methods analyzed. Nevertheless, preincisional infiltration provides good level of comfort in the immediate postoperative period when analgesia is most urgent.

  1. Designing safety into the minimally invasive surgical revolution: a commentary based on the Jacques Perissat Lecture of the International Congress of the European Association for Endoscopic Surgery.

    PubMed

    Clarke, John R

    2009-01-01

    Surgical errors with minimally invasive surgery differ from those in open surgery. Perforations are typically the result of trocar introduction or electrosurgery. Infections include bioburdens, notably enteric viruses, on complex instruments. Retained foreign objects are primarily unretrieved device fragments and lost gallstones or other specimens. Fires and burns come from illuminated ends of fiber-optic cables and from electrosurgery. Pressure ischemia is more likely with longer endoscopic surgical procedures. Gas emboli can occur. Minimally invasive surgery is more dependent on complex equipment, with high likelihood of failures. Standardization, checklists, and problem reporting are solutions for minimizing failures. The necessity of electrosurgery makes education about best electrosurgical practices important. The recording of minimally invasive surgical procedures is an opportunity to debrief in a way that improves the reliability of future procedures. Safety depends on reliability, designing systems to withstand inevitable human errors. Safe systems are characterized by a commitment to safety, formal protocols for communications, teamwork, standardization around best practice, and reporting of problems for improvement of the system. Teamwork requires shared goals, mental models, and situational awareness in order to facilitate mutual monitoring and backup. An effective team has a flat hierarchy; team members are empowered to speak up if they are concerned about problems. Effective teams plan, rehearse, distribute the workload, and debrief. Surgeons doing minimally invasive surgery have a unique opportunity to incorporate the principles of safety into the development of their discipline.

  2. An intraocular micro light-emitting diode device for endo-illumination during pars plana vitrectomy.

    PubMed

    Koelbl, Philipp S; Lingenfelder, Christian; Spraul, Christoph W; Kampmeier, Juergen; Koch, Frank Hj; Kim, Yong Keun; Hessling, Martin

    2018-03-01

    Development of a new, fiber-free, single-use endo-illuminator for pars plana vitrectomy as a replacement for fiber-based systems with external light sources. The hand-guided intraocularly placed white micro light-emitting diode is evaluated for its illumination properties and potential photochemical and thermal hazards. A micro light-emitting diode was used to develop a single-use intraocular illumination system. The light-source-on-tip device was implemented in a prototype with 23G trocar compatible outer diameter of 0.6 mm. The experimental testing was performed on porcine eyes. All calculations of possible photochemical and thermal hazards during the application of the intraocular micro light-emitting diode were calculated according to DIN EN ISO 15007-2: 2014. The endo-illuminator generated a homogeneous and bright illumination of the intraocular space. The color impression was physiologic and natural. Contrary to initial apprehension, the possible risk caused by inserting a light-emitting diode into the intraocular vitreous was much smaller when compared to conventional fiber-based illumination systems. The photochemical and thermal hazards allowed a continuous exposure time to the retina of at least 4.7 h. This first intraocular light source showed that a light-emitting diode can be introduced into the eye. The system can be built as single-use illumination system. This light-source-on-tip light-emitting diode-endo-illumination combines a chandelier wide-angle illumination with an adjustable endo-illuminator.

  3. New illuminations approaches with single-use micro LEDs endoilluminators for the pars plana vitrectomy

    NASA Astrophysics Data System (ADS)

    Koelbl, Philipp Simon; Koch, Frank H. J.; Lingenfelder, Christian; Hessling, Martin

    2018-02-01

    The illumination of the intraocular space during pars plana vitrectomy always bears the risk of retina damage by irradiation. Conventional illumination systems consist of an external light source and an optical fiber to transfer the visible light (radiation) into the eye. Often xenon arc and halogen lamps are employed for this application with some disadvantageous properties like high phototoxicity and low efficiency. Therefore, we propose to generate the light directly within the eye by inserting a white micro LED with a diameter of 0.6 mm. The LED offers a luminous flux of 0.6 lm of white light with a blue peak @ 450 nm and a yellow peak @ 555 nm. The presented prototypes fit through a standard 23 G trocar and are the first intraocular light sources worldwide. Two different single-use approaches have already been developed: a handguided and a chandelier device. The hand-guided applicator enables a directly navigation and illumination up to a working distance of 6 mm. The chandelier device is much smaller and does not need an active navigation of the light cone. The brightness and homogeneity of the illumination of these LED devices have been successfully tested on porcine eyes. Presented measurements and calculations prove that even for high LED currents and small distances to the retina these intraocular micro LED devices expose the retina to less hazard than conventional illumination sources like fiber based xenon systems. Even under the worst circumstances application durations of 180 hours would be justifiable.

  4. New generation intraoperative three-dimensional imaging (O-arm) in 100 spine surgeries: does it change the surgical procedure?

    PubMed

    Sembrano, Jonathan N; Santos, Edward Rainier G; Polly, David W

    2014-02-01

    The O-arm (Medtronic Sofamor Danek, Inc., Memphis, TN, USA), an intraoperative CT scan imaging system, may provide high-quality imaging information to the surgeon. To our knowledge, its impact on spine surgery has not been studied. We reviewed 100 consecutive spine surgical procedures which utilized the new generation mobile intraoperative CT imaging system (O-arm). The most common diagnoses were degenerative conditions (disk disease, spondylolisthesis, stenosis and acquired kyphosis), seen in 49 patients. The most common indication for imaging was spinal instrumentation in 81 patients (74 utilized pedicle screws). In 52 (70%) of these, the O-arm was used to assess screw position after placement; in 22 (30%), it was coupled with Stealth navigation (Medtronic Sofamor Danek, Inc.) to guide screw placement. Another indication was to assess adequacy of spinal decompression in 38 patients; in 19 (50%) of these, intrathecal contrast material was used to obtain an intraoperative CT myelogram. In 20 patients O-arm findings led to direct surgeon intervention in the form of screw removal/repositioning (n=13), further decompression (n=6), interbody spacer repositioning (n=1), and removal of kyphoplasty trocar (n=1). In 20% of spine surgeries, the procedure was changed based on O-arm imaging findings. We found the O-arm to be useful for assessment of instrumentation position, adequacy of spinal decompression, and confirmation of balloon containment and cement filling in kyphoplasty. When used with navigation for image-guided surgery, it obviated the need for registration. Published by Elsevier Ltd.

  5. Laparoscopic surgery of esophageal hiatus hernia – single center experience

    PubMed Central

    Piątkowski, Jacek; Jackowski, Marek

    2014-01-01

    Introduction Esophageal hiatal hernias are the most frequent types of internal hernias. This condition involves disturbance of normal functioning of the stomach cardiac mechanism and reflux of the gastric contents to the esophagus. Aim: To evaluate postoperative results in our Clinic and the comparison of these results to data from the literature. Material and methods One hundred and seventy-eight patients underwent surgery due to esophageal hiatal hernia at the Clinic of General, Gastroenterological and Oncological Surgery, Collegium Medicum, Bydgoszcz, Nicolaus Copernicus University, Torun, Poland, from 2006 to 2011. All operations were performed using laparoscopy. Fundoplication by means of the Nissen-Rossetti method was carried out in 172 patients while Toupet's and Dor's methods were applied in 4 and 2 patients, respectively. Results Average time of the surgery was 82 min (55–140 min). Conversion was performed in 4 cases. No serious intraoperative complications were noted. In the postoperative period, dysphagia was reported in 20 patients (11.2%). Postoperative wound infection was observed in 1 patient (0.56%). Hernias in the trocar insertion area were reported in 3 patients (1.68%). Ailments recurred in 6 patients. The recurrence of esophageal hiatal hernia was confirmed in 2 patients. Patients with recurrent hernia were re-operated using a laparoscopic approach. Conclusions Laparoscopic surgery is a simple and effective approach for patients with gastroesophageal reflux symptoms due to diaphragmatic esophageal hiatus hernia. The number of complications is lower after laparoscopic procedures than after “open” operations. PMID:24729804

  6. Learning Kinematic Constraints in Laparoscopic Surgery

    PubMed Central

    Huang, Felix C.; Mussa-Ivaldi, Ferdinando A.; Pugh, Carla M.; Patton, James L.

    2012-01-01

    To better understand how kinematic variables impact learning in surgical training, we devised an interactive environment for simulated laparoscopic maneuvers, using either 1) mechanical constraints typical of a surgical “box-trainer” or 2) virtual constraints in which free hand movements control virtual tool motion. During training, the virtual tool responded to the absolute position in space (Position-Based) or the orientation (Orientation-Based) of a hand-held sensor. Volunteers were further assigned to different sequences of target distances (Near-Far-Near or Far-Near-Far). Training with the Orientation-Based constraint enabled much lower path error and shorter movement times during training, which suggests that tool motion that simply mirrors joint motion is easier to learn. When evaluated in physically constrained (physical box-trainer) conditions, each group exhibited improved performance from training. However, Position-Based training enabled greater reductions in movement error relative to Orientation-Based (mean difference: 14.0 percent; CI: 0.7, 28.6). Furthermore, the Near-Far-Near schedule allowed a greater decrease in task time relative to the Far-Near-Far sequence (mean −13:5 percent, CI: −19:5, −7:5). Training that focused on shallow tool insertion (near targets) might promote more efficient movement strategies by emphasizing the curvature of tool motion. In addition, our findings suggest that an understanding of absolute tool position is critical to coping with mechanical interactions between the tool and trocar. PMID:23293709

  7. Laparoendoscopic single-site nephroureterectomy for morbid obese patients.

    PubMed

    Juliano, Cesar Augusto Braz; Carlos, Alexandre Stievano; Costa, Renato Meirelles Mariano; Tobias-Machado, Marcos; Pompeo, Antonio Carlos Lima

    2013-01-01

    Since the first laparoendoscopic single-site (LESS) surgery report in urology in 2007 (1) (Rane A e Cadeddu JA), the few reports of LESS extraperitoneal access in the literature were mainly described for less complex cases. The aim of this video is to demonstrate the feasibility of LESS extraperitoneal access in a morbid obese patient presenting a malignant tumor in the renal pelvis. The patient is positioned in 90-degree lateral decubitus. An incision is made below the abdominal skin crease on the left side of the patient and the anterior rectus fascia is vertically incised with manual dissection of the extra/retroperitoneal space. We use an Alexis® retractor to retract the skin maximizing the incision orifice. Three trocars (12, 10 and 5 mm) are inserted through a sigle-port. The pedicle was controlled "en bloc" with a vascular stapler and the bladder cuff treated by the conventional open approach through the same incision. Operative time was 126 minutes with minimal blood loss. The pathology reported high grade papillary urothelial carcinoma in the pelvis (pT3N0M0) and in the ureter (pTa). LESS extraperitoneal nephroureterectomy is feasible and safe, even in more complex cases. It is a good alternative for morbid obese patients and for patients with synchronous distal ureteral tumors for whom an open approach to the bladder cuff is proposed to avoid incisions in two compartments of the abdominal wall.

  8. Visceral and gastrointestinal complications in robotic urologic surgery.

    PubMed

    Velilla, G; Redondo, C; Sánchez-Salas, R; Rozet, F; Cathelineau, X

    2018-03-01

    with the widespread use of minimally invasive techniques, robot-assisted urologic surgery has become widely adopted. Despite their infrequency, visceral and gastrointestinal complications could be life-threatening. To identify the main gastrointestinal injuries that occur in a robot-assisted urologic surgery. To know the overall incidence and how is their management. Search in PubMed of articles related to visceral and gastrointestinal complications in robot-assisted urology surgery, written in English or Spanish. Relevant publications as well literature reviews and chapters from books were reviewed. Along with vascular injuries, visceral and gastrointestinal lesions are among most dangerous complications. A complete preoperative study to individualize each patient characteristics and the correct use of imaging could help us to avoid complications in the first place. To know all the risky steps in the different robotic urologic procedures will let us anticipate the damage. Knowledge of main and most dangerous injuries in the different abdominal and pelvic organs is fully recommended. Early diagnosis and evaluation of lesions will let us an acute management during surgery. Recognition delay could change a repairable injury into a life-threatening situation. Despite the undeniable benefits of robotic approach, there are minor and major gastrointestinal injuries that all urologic surgeons must know. Those related with trocar placement are especially important. Immediate diagnosis and management is mandatory. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Robotic assisted surgery in pediatric gynecology: promising innovation in mini invasive surgical procedures.

    PubMed

    Nakib, Ghassan; Calcaterra, Valeria; Scorletti, Federico; Romano, Piero; Goruppi, Ilaria; Mencherini, Simonetta; Avolio, Luigi; Pelizzo, Gloria

    2013-02-01

    Robotic assisted surgery is not yet widely applied in the pediatric field. We report our initial experience regarding the feasibility, safety, benefits, and limitations of robot-assisted surgery in pediatric gynecological patients. Descriptive, retrospective report of experience with pediatric gynecological patients over a period of 12 months. Department of Pediatric Surgery, IRCCS Policlinico San Matteo Foundation. Children and adolescents, with a surgical diagnosis of ovarian and/or tubal lesions. Robot assembly time and operative time, days of hospitalization, time to cessation of pain medication, complication rate, conversion rate to laparoscopic procedure and trocar insertion strategy. Six children and adolescents (2.4-15 yrs), weighing 12-55 kg, underwent robotic assisted surgery for adnexal pathologies: 2 for ovarian cystectomy, 2 for oophorectomy, 1 for right oophorectomy and left salpingo-oophorectomy for gonadal disgenesis, 1 for exploration for suspected pelvic malformation. Mean operative time was 117.5 ± 34.9 minutes. Conversion to laparatomy was not necessary in any of the cases. No intra- or postoperative complications occurred. Initial results indicate that robotic assisted surgery is safely applicable in the pediatric gynecological population, although it is still premature to conclude that it provides better clinical outcomes than traditional laparoscopic surgery. Randomized, prospective, comparative studies will help characterize the advantages and disadvantages of this new technology in pediatric patients. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  10. The decisive role of the patient-side surgeon in robotic surgery.

    PubMed

    Sgarbura, Olivia; Vasilescu, Catalin

    2010-12-01

    Minimally invasive technology literature is mainly concerned about the feasibility of the robotic procedures and the performance of the console surgeon. However, few of these technologies could be applied without a well-trained team. Our goal was to demonstrate that robotic surgery depends more on the patient-side assistant surgeon's abilities than has been previously reported. In our department, 280 interventions in digestive, thoracic, and gynecological surgery were performed since the acquisition of the robotic equipment. There are three teams trained in robotic surgery with three console surgeons and four certified patient-side surgeons. Four more patient-side assistants were trained at our center. Trocar placement, docking and undocking of the robot, insertion of the laparoscopic instruments, and hemostatic maneuvers with various devices were quantified and compared. Assistants trained by using animal or cadaver surgery are more comfortable with the robotic instruments handling and with docking and undocking of the robot. Assistants who finalized their residency or attend their final year are more accurate with the insertion of the laparoscopic instrument to the targeted organ and more skillful with LigaSure or clip applier devices. Interventions that require vivid participation of the assistants have shorter assistant-depending time intervals at the end of the learning curve than at the beginning. Robotic surgery is a team effort and is greatly dependant on the performance of assistant surgeons. Interventions that have the benefit of a trained team are more rapid and secure.

  11. Single-port access laparoscopic reversal of Hartmann operation.

    PubMed

    Borowski, D W; Kanakala, V; Agarwal, A K; Tabaqchali, M A; Garg, D K; Gill, T S

    2011-08-01

    Single-port access offers cosmetic advantages in addition to the well-recognized benefits of standard multiport laparoscopic surgery, and can be performed with the use of standard straight instruments. We describe a technique of single-port access reversal of Hartmann colostomy by use of the colostomy site for access. After routine skin preparation and laparoscopic setup, the colostomy is mobilized from its mucocutaneous border, and the anvil of a circular stapler is secured to the distal lumen. By the use of a GelPoint system with 3 or 4 trocars, the intra-abdominal adhesions are divided and the splenic flexure is mobilized to achieve sufficient access to the abdominal and pelvic cavities and proximal colonic mobility. The rectal stump is mobilized to the mid rectum, starting from the posterior mesorectal fascia around to the anterior rectal wall. A tension-free colorectal anastomosis is secured with a standard circular stapling device inserted transanally, and leak tested. The colostomy wound is closed in standard fashion. Five patients underwent single-port access reversal of Hartmann resection (4 diverticular perforations and 1 pT3N0 colon cancer), with a mean operating time of 155 (range, 137-187) minutes and a median length of stay of 3 (range, 2-11) days. There were no conversions, major surgical morbidity, or deaths. Single-port access reversal of Hartmann colostomy through the stoma site is safe, and it offers additional cosmetic advantages with no apparent additional morbidity in comparison with standard multiport surgery.

  12. Microincision, aspiration cutter-assisted multifocal iris biopsy for melanoma.

    PubMed

    Finger, Paul T; Milman, Tatyana

    2017-01-19

    To describe a minimally invasive method to create multifocal full-thickness surgical iridectomy biopsies. Seven patients suspected to have diffuse iris melanoma underwent multifocal surgical iridectomy biopsy through a single 1.0-mm clear corneal incision. A 25-G inked trocar was used to create one visible corneal portal, through which the anterior chamber was filled with sodium hyaluronate 1%. Then, a 25-G aspiration cutter probe was introduced through the corneal incision such that the aspiration portal was occluded by the iris biopsy sites. Then aspiration (600 mm Hg) cutting (300 cuts per minute) was used to create full- and partial-thickness surgical iridectomy biopsies at multiple locations. After each biopsy the probe was removed, and its contents aspirated into a separate 3-mL syringe (marked by clock hour location). The sodium hyaluronate 1% was removed and wound checked for leakage. Diagnostic specimens were obtained in all cases. Five were found to be diffuse iris melanomas and 2 were indeterminate iris melanocytic proliferations. No patients developed a secondary increase in intraocular pressure, hyphema, infection, cataract, or vision loss. No cases of intraocular tumor dissemination were observed. No patient complained of glare or monocular diplopia. Three of 7 corneal wounds were self-sealing. Multifocal surgical iridectomy biopsy can be minimally invasive and effective allowing for partial- and full-thickness iris biopsy. Use of a 25-G aspiration cutting probe allowed for small incision surgery, rapid rehabilitation, and no significant complications.

  13. Laparoscopic mesh fixation using laser-assisted tissue soldering in a porcine model.

    PubMed

    Lanzafame, Raymond J; Soltz, Barbara A; Stadler, Istvan; Soltz, Robert

    2009-01-01

    Animal studies using open surgical models indicate that collagen solder is capable of fixation of surgical meshes without interfering with tissue integration, increasing adhesions, or increasing inflammation intraperitoneally. This study describes development of instrumentation and techniques for laparoscopic herniorrhaphy using laser-assisted soldering technology. Anesthetized 20 kg to 25 kg female Yorkshire pigs underwent laparoscopy with a 3-trocar technique. Parietex TET, Parietex TEC, and Prolene mesh segments (5 x 5 cm) were embedded in 55% collagen solder. Segments were inserted by using a specially designed introducer and affixed to the peritoneum by using prototype laser devices (1.45 micro, 4.5 W continuous wave, 5-mm spot, 55 degrees C set temperature) and a custom laparoscopic handpiece (IPOM). Parietex PCO mesh was inserted and affixed using the Endo-hernia stapler (Control). Animals were recovered and underwent second-look laparoscopy at 6 weeks. Mesh sites were harvested after animals were euthanized. The mesh-solder constructs were easily inserted and affixed in an IPOM approach. Prolene mesh tended to curl at its edges as the solder was melted. Postoperative healing was similar to that in Control segments in all cases. Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce the use of staples or other foreign bodies for laparoscopic mesh fixation, prevent tissue ischemia and possibly nerve entrapment, which result in severe postoperative pain and morbidity. Laser-assisted mesh fixation is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted.

  14. A Simple Technique for Jejunojejunal Revision in Laparoscopic Roux-en-Y Gastric Bypass.

    PubMed

    Spivak, Hadar

    2015-12-01

    The lengths of the bypassed segments in the initial laparoscopic roux-en-Y gastric bypass (LRYGB) are usually a matter of the individual surgeon's routine. The literature is inconclusive about the association between the Roux limbs' length and weight-loss or malabsorption (Stefanidis et al. Obes Surg. 21(1):119-24, 2011); (Rawlins et al. Surg Obes Relat Dis. 7(1):45-9, 2011). However, jejunojejunal anastomosis (JJ) "redo" and Roux limb length revision could be considered for patients with a very short Roux limb and weight loss failure or for short common channel and malabsorption. Complications of JJ may also require revision. In over 1000 LRYGBs since 2001, eight patients required JJ revision for failure to lose enough weight (n = 6), malabsorption (n = 1), and stricture (n = 1). Instead of completely taking down the JJ, a simple technique was evolved to keep the enteric limb continuity. In a following step, the biliopancreatic limbs have been transected from the JJ and reconnected proximal (for malabsorption) or distal (for weight loss failure). In this video, a step-by-step the laparoscopic technique for JJ revision and relocating the biliopancreatic limb is presented. Procedure takes 40-60 min to perform using four trocars and the hospital stay was 1-2 nights. No complications occurred during the procedures or postoperative period. Laparoscopic revision of JJ is feasible and safe and should be part of surgeons' options on the long-term management of patients post LRYGB.

  15. Laparoscopic stomach-partitioning gastrojejunostomy with reduced-port techniques for unresectable distal gastric cancer.

    PubMed

    Hirahara, Noriyuki; Matsubara, Takeshi; Hyakudomi, Ryoji; Hari, Yoko; Fujii, Yusuke; Tajima, Yoshitsugu

    2014-03-01

    The improvement of quality of life is of great importance in managing patients with far-advanced gastric cancer. We report a new cure and less invasive method of creating a stomach-partitioning gastrojejunostomy in reduced-port laparoscopic surgery for unresectable gastric cancers with gastric outlet obstruction. A 2.5-cm vertical intraumbilical incision was made, and EZ Access (Hakko Co., Ltd., Tokyo, Japan) was placed. After pneumoperitoneum was created, an additional 5-mm trocar was inserted in the right upper abdomen. A gastrojejunostomy was performed in the form of an antiperistaltic side-to-side anastomosis, in which the jejunal loop was elevated in the antecolic route and anastomosed to the greater curvature of the stomach using an endoscopic linear stapler. The jejunal loop together with the stomach was dissected with additional linear staplers just proximal to the common entry hole so that a functional end-to-end gastrojejunostomy was completed. At the same time, the stomach was partitioned using a linear stapler to leave a 2-cm-wide lumen in the lesser curvature. Subsequently, jejunojejunostomy was performed 30 cm distal to the gastrojejunostomy, and the stomach-partitioning gastrojejunostomy resembling Roux-en Y anastomosis was completed. All patients resumed oral intake on the day of operation. Neither anastomotic leakage nor anastomotic stricture was observed. Our less invasive palliative operation offers the utmost priority to improve quality of life for patients with unresectable gastric cancer.

  16. Return of the cadaver

    PubMed Central

    Krähenbühl, Swenn Maxence; Čvančara, Paul; Stieglitz, Thomas; Bonvin, Raphaël; Michetti, Murielle; Flahaut, Marjorie; Durand, Sébastien; Deghayli, Lina; Applegate, Lee Ann; Raffoul, Wassim

    2017-01-01

    Abstract Successful Plastic Surgery Residency training is subjected to evolving society pressure of lower hourly work weeks imposed by external committees, labor laws, and increased public awareness of patient care quality. Although innovative measures for simulation training of surgery are appearing, there is also the realization that basic anatomy training should be re-enforced and cadaver dissection is of utmost importance for surgical techniques. In the development of new technology for implantable neurostimulatory electrodes for the management of phantom limb pain in amputee patients, a design of a cadaveric model has been developed with detailed steps for innovative transfascicular insertion of electrodes. Overall design for electrode and cable implantation transcutaneous was established and an operating protocol devised. Microsurgery of the nerves of the upper extremities for interfascicular electrode implantation is described for the first time. Design of electrode implantation in cadaver specimens was adapted with a trocar delivery of cables and electrodes transcutaneous and stabilization of the electrode by suturing along the nerve. In addition, the overall operating arena environment with specific positions of the multidisciplinary team necessary for implantable electrodes was elaborated to assure optimal operating conditions and procedures during the organization of a first-in-man implantation study. Overall importance of plastic surgery training for new and highly technical procedures is of importance and particularly there is a real need to continue actual cadaveric training due to patient variability for nerve anatomic structures. PMID:28723767

  17. Return of the cadaver: Key role of anatomic dissection for plastic surgery resident training.

    PubMed

    Krähenbühl, Swenn Maxence; Čvančara, Paul; Stieglitz, Thomas; Bonvin, Raphaël; Michetti, Murielle; Flahaut, Marjorie; Durand, Sébastien; Deghayli, Lina; Applegate, Lee Ann; Raffoul, Wassim

    2017-07-01

    Successful Plastic Surgery Residency training is subjected to evolving society pressure of lower hourly work weeks imposed by external committees, labor laws, and increased public awareness of patient care quality. Although innovative measures for simulation training of surgery are appearing, there is also the realization that basic anatomy training should be re-enforced and cadaver dissection is of utmost importance for surgical techniques.In the development of new technology for implantable neurostimulatory electrodes for the management of phantom limb pain in amputee patients, a design of a cadaveric model has been developed with detailed steps for innovative transfascicular insertion of electrodes. Overall design for electrode and cable implantation transcutaneous was established and an operating protocol devised.Microsurgery of the nerves of the upper extremities for interfascicular electrode implantation is described for the first time. Design of electrode implantation in cadaver specimens was adapted with a trocar delivery of cables and electrodes transcutaneous and stabilization of the electrode by suturing along the nerve. In addition, the overall operating arena environment with specific positions of the multidisciplinary team necessary for implantable electrodes was elaborated to assure optimal operating conditions and procedures during the organization of a first-in-man implantation study.Overall importance of plastic surgery training for new and highly technical procedures is of importance and particularly there is a real need to continue actual cadaveric training due to patient variability for nerve anatomic structures.

  18. [Feasibility and preliminary technical experience of single incision plus one port laparoscopic total gastrectomy combined with π-shaped esophagojejunal anastomosis in surgical treatment of gastric cancer].

    PubMed

    Du, Guangsheng; Jiang, Enlai; Qiu, Yuan; Wang, Wensheng; Wang, Shuai; Li, Yunbo; Peng, Ke; Li, Xiang; Yang, Hua; Xiao, Weidong

    2018-05-25

    To explore the feasibility, safety, and preliminary technical experience of single incision plus one port laparoscopic total gastrectomy combined with π-shaped esophagojejunal anastomosis (SILT-π) in the surgical treatment of gastric cancer. Clinical data of 5 gastric cancer patients undergoing SILT-π operation at the Department of General Surgery, The Second Affiliated Hospital of the Army Medical University from August to October 2017 were retrospectively analyzed. A 2.5-3.0 cm incision around the umbilicus was made for placing the gloveport as the passage for the lens, and the instruments of the surgeon and the assistant. Another operative port was placed in the left upper quadrant with a 12-mm Trocar for the passage of the energy device, the endoscopic cutting closure, as well as the postoperative drainage tube. A D2 lymph node (LNs) dissection was regularly conducted. After the abdominal esophagus was routinely mobilized, a side-to-side esophagus-jejunum anastomosis was made through a gastric pre-pulling esophagojejunal π-shaped anastomosis. The transection was then performed with a ligation on the cardia (or esophagus above the upper margin of the tumor) using a sterilized hemp rope in order to better expose the abdominal esophagus. Throughout the course of reconstruction, the ligature rope was held by the assistant to hold down the esophagus to allow easier esophagojejunal anastomosis. A hole was then made on the posterior wall of the esophagus, between 2 cm and 3 cm above the ligature rope, and another hole was made at the anti-mesenteric border of the jejunum 40 cm distal to the Treitz ligament. A side-to-side esophagojejunal π-shaped anastomosis was performed through two holes. An entry hole was formed after the anastomosis. After checking the anastomosis, this entry hole was closed through an intestinal mesenteric hole pre-made on its opposite side. The resected esophagus and stomach, together with the afferent loop jejunum, were simultaneously

  19. Feasibility of therapeutic pneumoperitoneum in a large animal model using a microvaporisator.

    PubMed

    Reymond, M A; Hu, B; Garcia, A; Reck, T; Köckerling, F; Hess, J; Morel, P

    2000-01-01

    Multimodal therapy is used increasingly in advanced gastrointestinal tumors. Potential benefits of using an intraoperative adjuvant therapy during laparoscopy for cancer have been documented in animal studies. The aim of this study was to develop a device that could deliver such an intraoperative drug therapy. We developed a micropump suitable for minimally invasive surgery procedures that allowed microdroplets of therapeutic substance to be distributed into the pneumoperitoneum (CO2), creating a "therapeutic pneumoperitoneum." A closed-loop control system regulates drug delivery according to the gas flow. In vitro, the micropump is able to aerosolize various aqueous and ethanol solutions, including cytostatic and bacteriostatic drugs and adhesion-modulating agents. The size of the microdroplets has been optimized to prevent visual artifacts. The micropump was tested in an animal model (pig). The system was inserted into a 5-mm trocar. After insufflation of a 12-mm CO2 pneumoperitoneum, laparoscopic sigmoid colon resections could be performed with no special difficulties. No fog developed, and no system-related complication was observed. At autopsy, the active principle was distributed to all exposed peritoneal surfaces. As opposed to conventional peritoneal washing, therapeutic pneumoperitoneum reaches the entire peritoneal surface, allowing an optimal drug distribution. Drug diffusion into the tissues is enhanced by the intraperitoneal pressure. Precise determination of the instantaneous and total drug quantity is possible. Therefore, this drug delivery system has several advantages over conventional irrigation. Its potential domains of application are locoregional cancer therapy, prevention of port-site recurrences, immunomodulation, analgesia, peritonitis, and prevention of postoperative adhesions.

  20. Effect of bag extraction to prevent wound infection on umbilical port site wound on elective laparoscopic cholecystectomy: a prospective randomised clinical trial.

    PubMed

    Comajuncosas, Jordi; Hermoso, Judit; Jimeno, Jaime; Gris, Pere; Orbeal, Rolando; Cruz, Antonio; Parés, David

    2017-01-01

    Laparoscopic cholecystectomy is the gold standard treatment for gallbladder stones. Complications due to laparoscopic procedure are rare, but rate of wound infection in some studies is about 8 %. From January 2007 to December 2008, 320 laparoscopic cholecystectomies were performed at our hospital, and in 4.7 % of them, wound infection of the umbilical trocar was identified. We believe that this infection rate could be lower and that it is necessary to implement a new technique to reduce the wound infection. The aim of the study was to evaluate the benefits of bag extraction of gallbladder to prevent the wound infection. Two-arm, parallel, 1:1, randomised controlled trial (ISRCTN38095251). All patients suffering from symptomatic gallbladder stones of low risk were enrolled for this study and were divided into two groups in basics gallbladder extraction: with (80 patients) or, as usually, without bag (76 patients). All patients with cholecystitis or accidental gallbladder perforation were excluded. We compared all the results to establish whether meaningful differences were found. The final sample analysed (156 patients) consisted of 121 women and 35 men; there were 80 in the control group and 76 in the study group. There were 15 (9.6 %) diagnosed wound infections, eight cases in the study group and seven in the control group. There were no statistically significant differences. The determinant of wound infection in elective laparoscopic cholecystectomy is not the direct contact of the gallbladder with the wound; therefore, bag extraction is not necessary.

  1. Biotelemeters for Space Flights and Fetal Monitoring

    NASA Technical Reports Server (NTRS)

    Mundt, Carsten W.; Ricks, Robert D.; Hines, John W.

    1999-01-01

    Pill-shaped biotelemeters originally designed for space flight applications will soon be used for monitoring the health of a fetus during and after in-utero fetal surgery. The authors developed a family of biotelemeters that are not only small enough for rodent studies on board the space shuttle or international space station, but also fit through a 10 mm trocar, a plastic tube that is used in endoscopic fetal surgery to obtain minimally invasive access to the fetus. The first 'pill' measures pressure and temperature, and is currently undergoing long-term leakage and biocompatibility tests. A second pill under development measures pH and temperature. A prototype of the 'pH-pill' has been built and successfully tested and is presently being miniaturized into the same dimensions as the 'pressure pill'. Additional pills measuring heart rate, ECG, other ions such as calcium and potassium, and eventually glucose and blood gases, will follow. All pills are designed for ultra-low power consumption yielding lifetimes of up to 10 months in order to meet the requirements of fetal monitoring, but also to provide the capability of long-term space station experiments. Each pill transmits its pulse-interval-modulated signal on a unique carrier frequency in the frequency range of 174-216MHz. A custom-designed multi-channel receiver demodulates and decodes each pill signal and sends the data to a LabVIEW program that performs real-time data analysis and display. A patent for the pill family and its data analysis system is pending.

  2. Using cognitive task analysis to identify critical decisions in the laparoscopic environment.

    PubMed

    Craig, Curtis; Klein, Martina I; Griswold, John; Gaitonde, Krishnanath; McGill, Thomas; Halldorsson, Ari

    2012-12-01

    The aim of this study was to identify the critical decisions surgeons need to make regarding laparoscopic surgery, the information these decisions are based on, the strategies employed by surgeons to reach their objectives, and the difficulties experienced by novices. Laparoscopic training focuses on the development of technical skills. However, successful surgical outcomes are also dependent on appropriate decisions made during surgery, which are influenced by critical cues and the use of appropriate strategies. Novices might not be as adept at cue detection and strategy use. Participants were eight attending surgeons. The authors employed task-analytic techniques to identify critical decisions inherent in laparoscopy and the cues, strategies, and novice traps associated with these decisions. The authors used decision requirements tables to organize the data into the key decisions made during the preoperative, operative, and postoperative phases as well as the cues, strategies, and novice traps associated with these decisions. Key decisions identified for the preoperative phase included but were not limited to the decision of performing a laparoscopic versus open surgery, necessity to review the literature, practicing the procedure, and trocar placement. Some key decisions identified for the operative phase included converting to open surgery, performing angiograms, cutting tissue or organs, and reevaluation of the approach. Only one key decision was identified for the postoperative phrase: whether the surgeon's technique needs to be evaluated and revised. The laparoscopic environment requires complex decision making, and novices are prone to errors in their decisions. The information elicited in this study is applicable to laparoscopic training.

  3. Outcome of laparoscopic ovariohysterectomy or ovariectomy in dogs with von Willebrand disease or factor VII deficiency: 20 cases (2012-2014).

    PubMed

    Keeshen, Thomas P; Case, J Brad; Runge, Jeffrey J; Singh, Ameet; Mayhew, Philipp D; Steffey, Michele A; Culp, William T N

    2017-11-01

    OBJECTIVE To describe surgical techniques and perioperative management of dogs with von Willebrand disease (VWD) or factor VII (FVII) deficiency undergoing laparoscopic ovariohysterectomy or ovariectomy and evaluate outcomes. DESIGN Retrospective case series. ANIMALS 20 client-owned dogs with VWD (n = 16) or FVII deficiency (4). PROCEDURES Dogs with VWD or FVII deficiency that underwent laparoscopic ovariohysterectomy or ovariectomy between 2012 and 2014 were retrospectively identified via a multi-institutional review of medical records. RESULTS Median expression of von Willebrand factor was 19% (interquartile range, 18% to 30%). All 16 dogs with VWD were Doberman Pinschers, and all were pretreated with desmopressin; 4 also received cryoprecipitate. One of 4 dogs with FVII deficiency received plasma preoperatively, and 1 was treated with desmopressin; 2 dogs received no preoperative treatment. Laparoscopic ovariectomy was performed in 9 dogs with VWD and 2 dogs with FVII deficiency, laparoscopic ovariectomy with gastropexy was performed in 6 dogs with VWD and 1 dog with FVII deficiency, and laparoscopic-assisted ovariohysterectomy was performed in 1 dog with VWD and 1 dog with FVII deficiency. Iatrogenic splenic laceration requiring conversion to laparotomy occurred during trocar insertion in 1 dog with VWD. No postoperative complications, including signs of hemorrhage, were reported for any dogs. CONCLUSIONS AND CLINICAL RELEVANCE Laparoscopic ovariohysterectomy or ovariectomy in dogs with VWD or FVII deficiency pretreated with desmopressin, cryoprecipitate, or plasma transfusions were not associated with clinical signs of hemorrhage, suggesting that minimally invasive ovariohysterectomy or ovariectomy may be considered in female dogs affected with these coagulopathies.

  4. Laparoscopic training model using fresh human cadavers without the establishment of penumoperitoneum

    PubMed Central

    Imakuma, Ernesto Sasaki; Ussami, Edson Yassushi; Meyer, Alberto

    2016-01-01

    BACKGROUND: Laparoscopy is a well-established alternative to open surgery for treating many diseases. Although laparoscopy has many advantages, it is also associated with disadvantages, such as slow learning curves and prolonged operation time. Fresh frozen cadavers may be an interesting resource for laparoscopic training, and many institutions have access to cadavers. One of the main obstacles for the use of cadavers as a training model is the difficulty in introducing a sufficient pneumoperitoneum to distend the abdominal wall and provide a proper working space. The purpose of this study was to describe a fresh human cadaver model for laparoscopic training without requiring a pneumoperitoneum. MATERIALS AND METHODS AND RESULTS: A fake abdominal wall device was developed to allow for laparoscopic training without requiring a pneumoperitoneum in cadavers. The device consists of a table-mounted retractor, two rail clamps, two independent frame arms, two adjustable handle and rotating features, and two frames of the abdominal wall. A handycam is fixed over a frame arm, positioned and connected through a USB connection to a television and dissector; scissors and other laparoscopic materials are positioned inside trocars. The laparoscopic procedure is thus simulated. CONCLUSION: Cadavers offer a very promising and useful model for laparoscopic training. We developed a fake abdominal wall device that solves the limitation of space when performing surgery on cadavers and removes the need to acquire more costly laparoscopic equipment. This model is easily accessible at institutions in developing countries, making it one of the most promising tools for teaching laparoscopy. PMID:27073318

  5. Reverse alignment "mirror image" visualization as a laparoscopic training tool improves task performance.

    PubMed

    Dunnican, Ward J; Singh, T Paul; Ata, Ashar; Bendana, Emma E; Conlee, Thomas D; Dolce, Charles J; Ramakrishnan, Rakesh

    2010-06-01

    Reverse alignment (mirror image) visualization is a disconcerting situation occasionally faced during laparoscopic operations. This occurs when the camera faces back at the surgeon in the opposite direction from which the surgeon's body and instruments are facing. Most surgeons will attempt to optimize trocar and camera placement to avoid this situation. The authors' objective was to determine whether the intentional use of reverse alignment visualization during laparoscopic training would improve performance. A standard box trainer was configured for reverse alignment, and 34 medical students and junior surgical residents were randomized to train with either forward alignment (DIRECT) or reverse alignment (MIRROR) visualization. Enrollees were tested on both modalities before and after a 4-week structured training program specific to their modality. Student's t test was used to determine differences in task performance between the 2 groups. Twenty-one participants completed the study (10 DIRECT, 11 MIRROR). There were no significant differences in performance time between DIRECT or MIRROR participants during forward or reverse alignment initial testing. At final testing, DIRECT participants had improved times only in forward alignment performance; they demonstrated no significant improvement in reverse alignment performance. MIRROR participants had significant time improvement in both forward and reverse alignment performance at final testing. Reverse alignment imaging for laparoscopic training improves task performance for both reverse alignment and forward alignment tasks. This may be translated into improved performance in the operating room when faced with reverse alignment situations. Minimal lab training can account for drastic adaptation to this environment.

  6. Influence of body weight and body conformation on the pressure-volume curve during capnoperitoneum in dogs.

    PubMed

    Dorn, Melissa J; Bockstahler, Barbara A; Dupré, Gilles P

    2017-05-01

    OBJECTIVE To evaluate the pressure-volume relationship during capnoperitoneum in dogs and effects of body weight and body conformation. ANIMALS 86 dogs scheduled for routine laparoscopy. PROCEDURES Dogs were allocated into 3 groups on the basis of body weight. Body measurements, body condition score, and body conformation indices were calculated. Carbon dioxide was insufflated into the abdomen with a syringe, and pressure was measured at the laparoscopic cannula. Volume and pressure data were processed, and the yield point, defined by use of a cutoff volume (COV) and cutoff pressure (COP), was calculated. RESULTS 20 dogs were excluded because of recording errors, air leakage attributable to surgical flaws, or trocar defects. For the remaining 66 dogs, the pressure-volume curve was linear-like until the yield point was reached, and then it became visibly exponential. Mean ± SD COP was 5.99 ± 0.805 mm Hg. No correlation was detected between yield point, body variables, or body weight. Mean COV was 1,196.2 ± 697.9 mL (65.15 ± 20.83 mL of CO 2 /kg), and COV was correlated significantly with body weight and one of the body condition indices but not with other variables. CONCLUSION AND CLINICAL RELEVANCE In this study, there was a similar COP for all dogs of all sizes. In addition, results suggested that increasing the abdominal pressure after the yield point was reached did not contribute to a substantial increase in working space in the abdomen. No correlation was found between yield point, body variables, and body weight.

  7. Confocal microlaparoscope for imaging the fallopian tube

    NASA Astrophysics Data System (ADS)

    Wu, Tzu-Yu; Schafer, Rachel; Rouse, Andrew R.; Gmitro, Arthur F.

    2012-02-01

    Recent evidence suggests that epithelial ovarian cancer may originate in the fimbriated end of the fallopian tube1. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. We have previously reported on a rigid confocal microlaparoscope system that is currently undergoing a clinical trial to image the epithelial surface of the ovary2. In order to gain in vivo access to the fallopian tubes we have developed a new confocal microlaparoscope with an articulating distal tip. The new instrument builds upon the technology developed for the existing confocal microlaparoscope. It has an ergonomic handle fabricated by a rapid prototyping printer. While maintaining compatibility with a 5 mm trocar, the articulating distal tip of the instrument consists of a 2.2 mm diameter bare fiber bundle catheter with automated dye delivery for fluorescence imaging. This small and flexible catheter design should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Early ex vivo mages of human fallopian tube and in vivo imaging results from recent open surgeries using the rigid confocal microlaparoscope system are presented. Ex vivo images from animal models using the new articulating bare fiber system are also presented. These high quality images collected by the new flexible system are similar in quality to those obtained from the epithelial surface of ovaries with the rigid clinical confocal microlaparoscope.

  8. Operative technique and early experience for robotic-assisted laparoscopic nephroureterectomy (RALNU) using da Vinci Xi.

    PubMed

    Darwiche, Fadi; Swain, Sanjaya; Kallingal, George; Punnen, Sanoj; Manoharan, Murugesan; Parekh, Dipen J; Gonzalgo, Mark L

    2015-01-01

    Robotic-assisted laparoscopic nephroureterectomy (RALNU) has been previously utilized for management of upper tract urothelial carcinoma. The da Vinci Xi surgical system was released in April of 2014. We describe our operative technique and early experience for RALNU using the da Vinci Xi system highlighting unique features of this surgical platform. A total of 10 patients with a diagnosis of upper tract urothelial carcinoma underwent RALNU using the da Vinci Xi system between April and November of 2014. A novel, oblique "in line" robotic trocar configuration was utilized to access the upper abdomen (nephrectomy portion) and pelvis (bladder cuff excision) without undocking. The port hopping feature of da Vinci Xi was utilized to facilitate optimal, multi-quadrant visualization during RALNU. Robotic-assisted laparoscopic nephroureterectomy was successfully completed without open conversion in all 10 patients. Mean operative time was 184 min (range 140-300 min), mean estimated blood loss was 121 cc (range 60-300 cc), and mean hospital stay was 2.4 days. Final pathology demonstrated high grade urothelial carcinoma in all patients. Surgical margins were negative in all patients. No intra-operative complications were encountered. One patient developed a pulmonary embolus after being discharged. No patients required a blood transfusion. Mean patient follow-up was 130 days (range 15-210 days). The use of da Vinci Xi with a novel, oblique "in line" port configuration and camera port hopping technique allows for an efficient and reproducible method for RALNU without the need for repositioning the patient or the robot during surgery.

  9. Morphological changes in the sciatic nerve, skeletal muscle, heart and brain of rabbits receiving continuous sciatic nerve block with 0.2% ropivacaine.

    PubMed

    Zhou, Yangning; He, Miao; Zou, Tianxiao; Yu, Bin

    2015-01-01

    To investigate the morphological changes in various tissues of rabbits receiving sciatic nerve block with 0.2% ropivacaine for 48 h. Twenty healthy were randomly assigned to normal saline group (N group) and ropivacaine group (R group). The right sciatic nerve was exposed, and a nerve-blocking trocar cannula embedded. Animals received an injection of 0.5% ropivacaine hydrochloride at a dose of 0.75 ml/kg. Rabbit was then connected to an infusion pump containing 50 ml of normal saline in N group, or to a infusion pump containing 0.2% ropivacaine hydrochloride in R group at 0.25 ml/kg•h-1. In both R group and N group, a small number of nerve cells exhibited pyknotic degeneration. More nerve cells with pyknotic degeneration were found in R group than in N group (P<0.001). At 48 h after surgery, there was a significant correlation between the abnormality of right hind limb and the degree of edema in sciatic nerve (P<0.01). Pyknotic degeneration of sciatic nerve increased after an infusion of 0.2% ropivacaine hydrochloride for 48 h, suggesting the neurotoxicity of ropivacaine. An infusion of 0.2% ropivacaine hydrochloride for 48 h may cause necrosis of skeletal muscle cells. The sciatic nerve edema would greatly affect the hindlimb motor while both pyknotic degeneration of sciatic nerve and skeletal muscle have little influence on the hindlimb movement. After an infusion of 0.2% ropivacaine hydrochloride for 48 h, the morphology of right atrium and brain tissues around the ventriculus tertius and medulla oblongata remained unchanged.

  10. Laparoscopic optical coherence tomographic imaging of human ovarian cancer

    NASA Astrophysics Data System (ADS)

    Hariri, Lida P.; Bonnema, Garret T.; Schmidt, Kathy; Hatch, Kenneth; Brewer, Molly; Barton, Jennifer K.

    2008-02-01

    Ovarian cancer is the fourth leading cause of cancer-related death among women in the United States. If diagnosed at an early stage, the 5-year survival rate is 94%, but drops to 68% for regional disease and 29% for distant metastasis; only 19% of all cases are diagnosed at the early, localized stage. Optical coherence tomography is a recently emerging non-destructive imaging technology, achieving high axial resolutions (10-20 microns) at imaging depths up to 2 mm. Previously, we studied OCT imaging in normal and diseased human ovary ex vivo to determine the features OCT is capable of resolving. Changes in collagen were suggested with several of the images that correlated with changes in collagen seen in malignancy. Areas of necrosis and blood vessels were also visualized using OCT, indicative of an underlying tissue abnormality. We recently developed a custom side-firing laparoscopic OCT (LOCT) probe fabricated specifically for in vivo laparoscopic imaging. The LOCT probe consists of a 38 mm diameter handpiece terminated in an 280 mm long, 4.6 mm diameter tip for insertion into the laparoscopic trocar and is capable of obtaining up to 9.5 mm image lengths at 10 micron axial resolution. In this study, we utilize the LOCT probe to image one or both ovaries of 20 patients undergoing laparotomy or transabdominal endoscopy and oophorectomy to determine if OCT is capable of identifying and/or differentiating normal and neoplastic ovary. To date, we have laparoscopically imaged the ovaries of ten patients successfully with no known complications.

  11. Laparoscopic optical coherence tomographic imaging of human ovarian cancer

    NASA Astrophysics Data System (ADS)

    Hariri, Lida P.; Bonnema, Garret T.; Schmidt, Kathy; Korde, Vrushali; Winkler, Amy M.; Hatch, Kenneth; Brewer, Molly; Barton, Jennifer K.

    2009-02-01

    Ovarian cancer is the fourth leading cause of cancer-related death among women. If diagnosed at early stages, 5-year survival rate is 94%, but drops to 68% for regional disease and 29% for distant metastasis; only 19% of cases are diagnosed at early, localized stages. Optical coherence tomography is a recently emerging non-destructive imaging technology, achieving high axial resolutions (10-20 µm) at imaging depths up to 2 mm. Previously, we studied OCT in normal and diseased human ovary ex vivo. Changes in collagen were suggested with several images that correlated with changes in collagen seen in malignancy. Areas of necrosis and blood vessels were also visualized using OCT, indicative of an underlying tissue abnormality. We recently developed a custom side-firing laparoscopic OCT (LOCT) probe fabricated for in vivo imaging. The LOCT probe, consisting of a 38 mm diameter handpiece terminated in a 280 mm long, 4.6 mm diameter tip for insertion into the laparoscopic trocar, is capable of obtaining up to 9.5 mm image lengths at 10 µm axial resolution. In this pilot study, we utilize the LOCT probe to image one or both ovaries of 17 patients undergoing laparotomy or transabdominal endoscopy and oophorectomy to determine if OCT is capable of differentiating normal and neoplastic ovary. We have laparoscopically imaged the ovaries of seventeen patients with no known complications. Initial data evaluation reveals qualitative distinguishability between the features of undiseased post-menopausal ovary and the cystic, non-homogenous appearance of neoplastic ovary such as serous cystadenoma and endometroid adenocarcinoma.

  12. LAVH for large uteri by various strategies.

    PubMed

    Chang, Wen-Chun; Huang, Su-Cheng; Sheu, Bor-Ching; Torng, Pao-Ling; Hsu, Wen-Chiung; Chen, Szu-Yu; Chang, Daw-Yuan

    2008-01-01

    To study if there are specific problems in laparoscopically assisted vaginal hysterectomy (LAVH) for a certain weight of bulky uteri and the strategies to overcome such problems. One hundred and eighty-one women with myoma or adenomyosis, weighing 350-1,590 g, underwent LAVH between August 2002 and December 2005. Key surgical strategies were special sites for trocar insertion, uterine artery or adnexal collateral pre-ligation, laparoscopic and transvaginal volume reduction technique. The basic clinical and operative parameters were recorded for analysis. Based on significant differences in the operative time and estimated blood loss, the patients were divided into medium uteri weighing 350-749 g, n=138 (76%), and large uteri weighing > or =750 g, n=43 (24%). There was no significant difference in terms of age, body mass index, preoperative diagnoses, complications and duration of hospital stay among groups. The operative time and estimated blood loss increased with larger uterine size (p<0.001). The operative time (196+/-53, 115-395 min), estimated blood loss (234+/-200, 50-1,000 ml) and frequency of excessive bleeding (14%) or transfusion (5%) were significantly greater, but in acceptable ranges, for those with large uteri. Conversion to laparotomy was required in a patient (2%) with a large uterus, and the overall conversion rate was 0.6%. There was no re-operation or surgical mortality. Using various combinations of special strategies, most experienced gynecologic surgeons can conduct LAVH for most large uteri with minimal rates of complications and conversion to laparotomy.

  13. Percutaneous nephroscopic management of an isolated giant renal hydatid cyst guided by single-incision laparoscopy using conventional instruments: the Santosh-PGI technique.

    PubMed

    Kumar, Santosh; Choudhary, Gautam R; Pushkarna, Arawat; Najjapa, Bhuvnesh; Ht, Vatasla

    2013-11-01

    Isolated renal hydatid rarely presents, but when it does occur, it requires surgical treatment. We report our experience with a novel technique involving percutaneous management of a giant renal hydatid cyst with single-incision laparoscopic assistance. First we performed retrograde ureteropyelogram, which did not show any communication between the cyst and the calyceal. A Veress needle was used for pneumoperitoneum. Three conventional laparoscopic trocars used. Under laparoscopic guidance, we punctured the cyst. The scolicidal solution used was 10% povidone-iodine. The endocyst was removed under vision with grasping forceps through the nephroscope. A Portex drain was placed into the cyst cavity. Percutaneous aspiration and instillation of scolicidal agents followed by re-aspiration have been previously reported. This is an attractive procedure because of its acceptable success rates and reduced morbidity. In our case, simple aspiration of the cyst would not have been successful because the cyst was full of daughter cysts. Also, a blind percutaneous puncture of the cyst and dilatation could have perforated the colon or the mesocolon, which is often wrapped over the surface of such giant cysts thereby making laparoscopic guidance and mobilization of the colon imperative. We devised this unique treatment method for this patient involving three conventional ports at a single umbilical site. We believe this is the first reported case of its kind in the world. Not only this technique is minimally invasive, it is also cost-effective, as only conventional laparoscopic ports and instruments are used during the procedure. © 2013 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  14. Standardized technique for single-incision laparoscopic-assisted stoma creation.

    PubMed

    Miyoshi, Norikatsu; Fujino, Shiki; Ohue, Masayuki; Yasui, Masayoshi; Noura, Shingo; Wada, Yuma; Kimura, Ryuichiro; Sugimura, Keijiro; Tomokuni, Akira; Akita, Hirofumi; Kobayashi, Shogo; Takahashi, Hidenori; Omori, Takeshi; Fujiwara, Yoshiyuki; Yano, Masahiko

    2016-08-10

    To describe the procedure, efficacy, and utility of single-incision laparoscopic-assisted stoma creation (SILStoma) for transverse colostomy. Using single-incision laparoscopic surgery, we developed a standardized technique for SILStoma. Twelve consecutive patients underwent SILStoma for transverse colostomy at Osaka Medical Center for Cancer and Cardiovascular Diseases from April 2013 to March 2016. A single, intended stoma site was created with a 2.5-3.5 cm skin incision for primary access to the intra-abdominal space, and it functioned as the main port through which multi-trocars were placed. Clinical and operative factors and postoperative outcomes were evaluated. Patient demographics, including age, gender, body mass index, and surgical indications for intestinal diversion were evaluated. SILStoma was performed in nine cases without the requirement of additional ports. In the remaining three cases, 1-2 additional 5-mm ports were required for mobilization of the transverse colon and safe dissection of abdominal adhesions. No cases required conversion to open surgery. In all cases, SILStoma was completed at the initial stoma site marked preoperatively. No intraoperative or postoperative complications greater than Grade II (the Clavien-Dindo classification) were reported in the complication survey. Surgical site infection at stoma sites was observed in four cases; however, surgical interventions were not required and all infections were cured completely. In all cases, the resumption of bowel movements was observed between postoperative days 1 and 2. SILStoma for transverse loop colostomy represents a feasible surgical procedure that allows the creation of a stoma at the preoperatively marked site without any additional large skin incisions.

  15. Surgical resident evaluations of portable laparoscopic box trainers incorporated into a simulation-based minimally invasive surgery curriculum.

    PubMed

    Zapf, Matthew A C; Ujiki, Michael B

    2015-02-01

    Box trainers have been shown to be an effective tool for teaching laparoscopic skills; however, residents are challenged to find practice time. Portable trainers theoretically allow for extended hands on practice out of the hospital. We aimed to report resident experience with laparoscopic home box trainers. Over 2 years, all residents rotating through a minimally invasive service were given a portable trainer and access to a surgical simulation lab for practice. Each trainer contained a collapsible frame, a webcam with USB port, trocars, and laparoscopic instruments (needle driver, shears, Maryland and straight dissecting graspers) as well as Fundamentals of Laparoscopic Surgery skills testing materials. Residents were asked to log hours, usages, and their experience anonymously. Twenty-three residents received a portable trainer. Fifty percent of the participants found the trainer useful or very useful, 25% said it was not useful, and 25% did not access the trainer. Those that used the trainer during their rotation did so 3.1 ± 3.0 times for 2.9 ± 3.0 hours/week. After completing their rotation, 5 of 12 residents used their trainer for an average of 10.2 ± 9.4 hours. Forty-two percent of the responders liked the accessibility of the home box trainers, while 25% criticized the camera-computer interface. Portable box trainers are useful and can effectively supplement a laboratory-based surgical simulation curriculum; however, personal possession of a portable simulator does not result in voluntarily long-term practice. © The Author(s) 2014.

  16. Truly hybrid interventional MR/X-ray system: investigation of in vivo applications.

    PubMed

    Fahrig, R; Butts, K; Wen, Z; Saunders, R; Kee, S T; Sze, D Y; Daniel, B L; Laerum, F; Pelc, N J

    2001-12-01

    The purpose of this study was to provide in vivo demonstrations of the functionality of a truly hybrid interventional x-ray/magnetic resonance (MR) system. A digital flat-panel x-ray system (1,024(2) array of 200 microm pixels, 30 frames per second) was integrated into an interventional 0.5-T magnet. The hybrid system is capable of MR and x-ray imaging of the same field of view without patient movement. Two intravascular procedures were performed in a 22-kg porcine model: placement of a transjugular intrahepatic portosystemic shunt (TIPS) (x-ray-guided catheterization of the hepatic vein, MR fluoroscopy-guided portal puncture, and x-ray-guided stent placement) and mock chemoembolization (x-ray-guided subselective catheterization of a renal artery branch and MR evaluation of perfused volume). The resolution and frame rate of the x-ray fluoroscopy images were sufficient to visualize and place devices, including nitinol guidewires (0.016-0.035-inch diameter) and stents and a 2.3-F catheter. Fifth-order branches of the renal artery could be seen. The quality of both real-time (3.5 frames per second) and standard MR images was not affected by the x-ray system. During MR-guided TIPS placement, the trocar and the portal vein could be easily visualized, allowing successful puncture from hepatic to portal vein. Switching back and forth between x-ray and MR imaging modalities without requiring movement of the patient was demonstrated. The integrated nature of the system could be especially beneficial when x-ray and MR image guidance are used iteratively.

  17. Evaluation of Protocol Uniformity Concerning Laparoscopic Cholecystectomy in The Netherlands

    PubMed Central

    Goossens, Richard H. M.; van Eijk, Daan J.; Lange, Johan F.

    2008-01-01

    Background Iatrogenic bile duct injury remains a current complication of laparoscopic cholecystectomy. One uniform and standardized protocol, based on the “critical view of safety” concept of Strasberg, should reduce the incidence of this complication. Furthermore, owing to the rapid development of minimally invasive surgery, technicians are becoming more frequently involved. To improve communication between the operating team and technicians, standardized actions should also be defined. The aim of this study was to compare existing protocols for laparoscopic cholecystectomy from various Dutch hospitals. Methods Fifteen Dutch hospitals were contacted for evaluation of their protocols for laparoscopic cholecystectomy. All evaluated protocols were divided into six steps and were compared accordingly. Results In total, 13 hospitals responded—5 academic hospitals, 5 teaching hospitals, 3 community hospitals—of which 10 protocols were usable for comparison. Concerning the trocar positions, only minor differences were found. The concept of “critical view of safety” was represented in just one protocol. Furthermore, the order of clipping and cutting the cystic artery and duct differed. Descriptions of instruments and apparatus were also inconsistent. Conclusions Present protocols differ too much to define a universal procedure among surgeons in The Netherlands. The authors propose one (inter)national standardized protocol, including standardized actions. This uniform standardized protocol has to be officially released and recommended by national scientific associations (e.g., the Dutch Society of Surgery) or international societies (e.g., European Association for Endoscopic Surgery and Society of American Gastrointestinal and Endoscopic Surgeons). The aim is to improve patient safety and professional communication, which are necessary for new developments. PMID:18224485

  18. Bilateral medial iliac lymph node excision by a ventral laparoscopic approach: technique description

    PubMed Central

    LIM, Hyunjoo; KIM, Jina; LI, Li; LEE, Aeri; JEONG, Junemoe; KO, Jonghyeok; LEE, Sungin; KWEON, Oh-Kyeong; KIM, Wan Hee

    2017-01-01

    The aim of this study was to describe a ventral laparoscopic technique for bilateral medial iliac lymphadenectomy in dogs. Twelve intact male purpose-bred research dogs, weighing less than 15 kg, were positioned in dorsal recumbency, and a 3-portal technique was used. Bilateral dissection was performed with vessel-sealing devices while tilting the surgical table by up to 30° towards the contralateral side of the target medial iliac lymph node (MILN) without changing the surgeon’s position. Using a ventral laparoscopic approach, bilateral MILNs were identified and excised in all dogs. The mean times for unilateral and bilateral MILN dissections were 9.7 ± 3.8 and 21.0 ± 6.0 min, respectively. The mean times for the right and left MILN dissections were 10.8 ± 4.3 and 9.8 ± 2.5 min, respectively. The mean total surgery time was 43.7 ± 7.7 min. In total, 26 MILNs were dissected. Several complications, including mild to moderate capillary hemorrhage from perinodal fat and vessels (controlled laparoscopically), mild spleen trauma caused by the first trocar insertion and capsular damage of MILNs, were observed. However, there were no other major complications. All MILN samples were evaluated and deemed suitable for histopathologic diagnosis. Laparoscopic excision of MILNs is a useful method of excisional biopsy for histopathologic diagnosis. Using this ventral laparoscopic approach with the 3-portal technique, bilateral MILN dissection suitable for obtaining histopathologic samples could be achieved in a short time in dogs weighing less than 15 kg. PMID:28781294

  19. Rectal transection using a curved cutter stapler with an endo-Satinsky clamp during a laparoscopic low anterior resection.

    PubMed

    Hotta, Tsukasa; Takifuji, Katsunari; Yokoyama, Shozo; Matsuda, Kenji; Yamaue, Hiroki

    2012-10-01

    A new rectal transaction method was developed using a combination of the curved cutter stapler and endo-Satinsky clamp because of the difficulty in performing rectal transection in the narrow pelvic cavity. The endo-Satinsky clamp is inserted without a flexible trocar cannula by connecting the handle extra-abdominally with a shaft of the endo-Satinsky clamp through the left higher quadrant port via a retrograde course from a midline incision above the pubis symphysis. The endo-Satinsky clamp is used to clamp the rectal wall horizontally at the distal end of the tumor. The wrist of an elastic surgical glove fixed with the shaft of the curved cutter stapler is covered with a midline incision, and consequently, the stapler is inserted into the pelvic cavity. The curved head of the stapler is rotated to the left at the anal side of the endo-Satinsky clamp to insert the rectum between the jaws of the stapler. The stapler is closed and fired, and a rectal transection is thus performed with one firing using a single cartridge. This method was performed in 12 patients with rectal cancer. The median value and range of the tumor distance from the anal verge were 7.0 and 4.5-11.0 cm, respectively. The median duration of the operation was 252 min, and the median blood loss was 15 mL. Only one stapling cartridge was used for rectal transection in all cases, and no major complications were observed. We herein demonstrated a new transection method for rectal cancer.

  20. Transumbilical laparoscopic Roux-en-Y gastric bypass with hand-sewn gastrojejunal anastomosis.

    PubMed

    Fernández, José Ignacio; Ovalle, Cristian; Farias, Carlos; de la Maza, Jaime; Cabrera, Carolina

    2013-01-01

    Single-port laparoscopic surgery has undergone significant development over the past 5 years. Single port is used in various procedures, including bariatric surgery. The aim of this paper is to describe a surgical technique for gastric bypass with a transumbilical approach (transumbilical gastric bypass-TUGB) with hand-sewn gastrojejunostomy, in selected patients who may be benefited by a better cosmetic result. The procedure begins with a transumbilical vertical incision. We use the GelPOINT single-port device and a 5-mm assistant trocar in the left flank (in the first two cases, a 2-mm subxiphoid liver retractor was used). A gastric pouch is made and calibrated with a 36-Fr bougie. The gastrojejunal anastomosis is performed by hand-sewing in two layers. A Roux-en-Y with a biliary limb of 50 cm and an alimentary limb of 120 cm is performed with a stapler. Three women were subjected to TUGB. The women were aged 28, 31, and 42 years; they had body mass indexes of 40.3, 33, and 38.2; and the operating times were 150, 200, and 150 min, respectively. The first two women underwent a Roux-en-Y gastric bypass (RYGB), and the last woman underwent a RYGB with a resection of the stomach remnant. There were no conversions to open or multitrocar techniques. No complications or deaths occurred. The three patients were satisfied with the cosmetic result. The technique described for TUGB is a feasible procedure for surgeons who have previous experience with the transumbilical approach.

  1. ROBOTIC ASSISTED SINGLE SITE FOR BILATERAL INGUINAL HERNIA REPAIR.

    PubMed

    Bosi, Henrique Rasia; Guimarães, José Ricardo; Cavazzola, Leandro Totti

    2016-01-01

    The inguinal hernia is one of the most frequent surgical diseases, being frequent procedure and surgeon´s everyday practice. To present technical details in making hernioplasty using robotic equipment on bilateral inguinal hernia repair with single port and preliminary results with the method. The bilateral inguinal hernia repair was performed by using the Single-Site(c) Da Vinci Surgical Access Platform to the abdominal cavity and the placement of clamps. This technique proved to be effective for inguinal hernia and have more aesthetic result when compared to other techniques. Inguinal hernia repair robot-assisted with single-trocar is feasible and effective. However, still has higher costs needing surgical team special training. A hérnia inguinal é uma das doenças cirúrgicas mais frequentes, tornando-a procedimento frequente e do cotidiano do cirurgião. Apresentar detalhes da técnica da hernioplastia inguinal bilateral robótica por single-site e resultados preliminares com o método. Foi realizada hernioplastia inguinal bilateral assistida por robô, utilizando-se da Vinci Single-Site(c) Surgical Platform para acesso a cavidade abdominal e colocação das pinças. Esta técnica demonstrou-se efetiva para correção da hérnia inguinal, além de apresentar melhor resultado estético quando comparado às outras técnicas. A hernioplastia inguinal assistida por robô com trocarte único é viável e eficaz. Contudo, ainda apresenta custos mais elevados e necessidade de treinamento especial por parte da equipe cirúrgica.

  2. Single-site multiport combined splenectomy and cholecystectomy with conventional laparoscopic instruments: Case series and review of literature

    PubMed Central

    Ozemir, Ibrahim Ali; Bayraktar, Baris; Bayraktar, Onur; Tosun, Salih; Bilgic, Cagri; Demiral, Gokhan; Ozturk, Erman; Yigitbasi, Rafet; Alimoglu, Orhan

    2015-01-01

    Introduction Conventional laparoscopic procedures have been used for splenic diseases and concomitant gallbladder stones, frequently in patients with hereditary spherocytosis since 1990’s. The aim of this study is to evaluate the feasibility of single-site surgery with conventional instruments in combined procedures. Presentation of case series Six consecutive patients who scheduled for combined cholecystectomy and splenectomy because of hereditary spherocytosis or autoimmune hemolytic anemia were included this study. Both procedures were performed via trans-umbilical single-site multiport approach using conventional instruments. All procedures completed successfully without conversion to open surgery or conventional laparoscopic surgery. An additional trocar was required for only one patient. The mean operation time was 190 min (150–275 min). The mean blood loss was 185 ml (70–300 ml). Median postoperative hospital stay was two days. No perioperative mortality or major complications occurred in our series. Recurrent anemia, hernia formation or wound infection was not observed during the follow-up period. Discussion Nowadays, publications are arising about laparoscopic or single site surgery for combined diseases. Surgery for combined diseases has some difficulties owing to the placement of organs and position of the patient during laparoscopic surgery. Single site laparoscopic surgery has been proposed to have better cosmetic outcome, less postoperative pain, greater patient satisfaction and faster recovery compared to standard laparoscopy. Conclusion We consider that single-site multiport laparoscopic approach for combined splenectomy and cholecystectomy is a safe and feasible technique, after gaining enough experience on single site surgery. PMID:26708949

  3. Contact forces during hybrid atrial fibrillation ablation: an in vitro evaluation.

    PubMed

    Lozekoot, Pieter W J; de Jong, Monique M J; Gelsomino, Sandro; Parise, Orlando; Matteucci, Francesco; Lucà, Fabiana; Kumar, N; Nijs, Jan; Czapla, Jens; Kwant, Paul; Bani, Daniele; Gensini, Gian Franco; Pison, Laurent; Crijns, Harry J G M; Maessen, Jos G; La Meir, Mark

    2016-03-01

    Data on epicardial contact force efficacy in dual epicardial-endocardial atrial fibrillation ablation procedures are lacking. We present an in vitro study on the importance of epicardial and endocardial contact forces during this procedure. The in vitro setup consists of two separate chambers, mimicking the endocardial and epicardial sides of the heart. A circuit, including a pump and a heat exchanger, circulates porcine blood through the endocardial chamber. A septum, with a cut out, allows the placement of a magnetically fixed tissue holder, securing porcine atrial tissue, in the middle of both chambers. Two trocars provide access to the epicardium and endocardium. Force transducers mounted on both catheter holders allow real-time contact force monitoring, while a railing system allows controlled contact force adjustment. We histologically assessed different combinations of epi-endocardial radiofrequency ablation contact forces using porcine atria, evaluating the ablation's diameters, area, and volume. An epicardial ablation with forces of 100 or 300 g, followed by an endocardial ablation with a force of 20 g did not achieve transmurality. Increasing endocardial forces to 30 and 40 g combined with an epicardial force ranging from 100 to 300 and 500 g led to transmurality with significant increases in lesion's diameters, area, and volumes. Increased endocardial contact forces led to larger ablation lesions regardless of standard epicardial pressure forces. In order to gain transmurality in a model of a combined epicardial-endocardial procedure, a minimal endocardial force of 30 g combined with an epicardial force of 100 g is necessary.

  4. Analysis of laparoscopic port site complications: A descriptive study

    PubMed Central

    Karthik, Somu; Augustine, Alfred Joseph; Shibumon, Mundunadackal Madhavan; Pai, Manohar Varadaraya

    2013-01-01

    CONTEXT: The rate of port site complications following conventional laparoscopic surgery is about 21 per 100,000 cases. It has shown a proportional rise with increase in the size of the port site incision and trocar. Although rare, complications that occur at the port site include infection, bleeding, and port site hernia. AIMS: To determine the morbidity associated with ports at the site of their insertion in laparoscopic surgery and to identify risk factors for complications. SETTINGS AND DESIGN: Prospective descriptive study. MATERIALS AND METHODS: In the present descriptive study, a total of 570 patients who underwent laparoscopic surgeries for various ailments between August 2009 and July 2011 at our institute were observed for port site complications prospectively and the complications were reviewed. STATISTICAL ANALYSIS USED: Descriptive statistical analysis was carried out in the present study. The statistical software, namely, SPSS 15.0 was used for the analysis of the data. RESULTS: Of the 570 patients undergoing laparoscopic surgery, 17 (3%) had developed complications specifically related to the port site during a minimum follow-up of three months; port site infection (PSI) was the most frequent (n = 10, 1.8%), followed by port site bleeding (n = 4, 0.7%), omentum-related complications (n = 2; 0.35%), and port site metastasis (n = 1, 0.175%). CONCLUSIONS: Laparoscopic surgeries are associated with minimal port site complications. Complications are related to the increased number of ports. Umbilical port involvement is the commonest. Most complications are manageable with minimal morbidity, and can be further minimized with meticulous surgical technique during entry and exit. PMID:23741110

  5. Laparoscopic Mesh Fixation Using Laser-Assisted Tissue Soldering in a Porcine Model

    PubMed Central

    Soltz, Barbara A.; Stadler, Istvan; Soltz, Robert

    2009-01-01

    Background and Objective: Animal studies using open surgical models indicate that collagen solder is capable of fixation of surgical meshes without interfering with tissue integration, increasing adhesions, or increasing inflammation intraperitoneally. This study describes development of instrumentation and techniques for laparoscopic herniorrhaphy using laser-assisted soldering technology. Study Design and Methods: Anesthetized 20 kg to 25 kg female Yorkshire pigs underwent laparoscopy with a 3-trocar technique. Parietex TET, Parietex TEC, and Prolene mesh segments (5 × 5 cm) were embedded in 55% collagen solder. Segments were inserted by using a specially designed introducer and affixed to the peritoneum by using prototype laser devices (1.45 µ, 4.5 W continuous wave, 5-mm spot, 55° C set temperature) and a custom laparoscopic handpiece (IPOM). Parietex PCO mesh was inserted and affixed using the Endo-hernia stapler (Control). Animals were recovered and underwent second-look laparoscopy at 6 weeks. Mesh sites were harvested after animals were euthanized. Results: The mesh-solder constructs were easily inserted and affixed in an IPOM approach. Prolene mesh tended to curl at its edges as the solder was melted. Postoperative healing was similar to that in Control segments in all cases. Discussion and Conclusion: Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce the use of staples or other foreign bodies for laparoscopic mesh fixation, prevent tissue ischemia and possibly nerve entrapment, which result in severe postoperative pain and morbidity. Laser-assisted mesh fixation is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted. PMID:19793465

  6. Transabdominal preperitoneal herniorrhaphy using laser-assisted tissue soldering in a porcine model.

    PubMed

    Lanzafame, Raymond J; Soltz, Barbara A; Stadler, Istvan; Soltz, Robert

    2009-01-01

    Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. Anesthetized 20-kg to 25-kg female Yorkshire pigs underwent laparoscopy performed using a 3-trocar technique. Peritoneal incisions were made and pockets created in the preperitoneal space for mesh placement. Parietex TEC mesh segments embedded in 60% collagen-solder were soldered to the muscle surface by using a prototype laser (1.45micro, 4.5W CW, 5mm spot, and 55 degrees C set temperature) and custom laparoscopic handpiece. Parietex TEC mesh segments (Control) were affixed to the muscle with fibrin sealant (Tisseel). Peritoneal closure was with staples (Control) or by soldering collagen embedded Vicryl mesh segments over the peritoneal incision (Mesh/TAPP). Segments were inserted using a specially designed introducer. Animals were recovered and underwent second-look laparoscopy at 6 weeks postimplantation. Mesh sites were harvested after animals were euthanized. The mesh-solder constructs were easily inserted and affixed in the TAPP approach. Tisseel tended to drip during application, particularly in vertical and ventral locations. Postoperative healing was similar to Control segments in all cases. Mesh/TAPP closures healed without scarring or adhesion formation. Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce use of staples for laparoscopic mesh fixation and peritoneal closure. Laser-assisted mesh fixation and peritoneal closure is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted.

  7. Risk Factors for Mycobacterium abscessus subsp. bolletii infection after laparoscopic surgery during an outbreak in Brazil.

    PubMed

    Baruque Villar, Gabriela; de Mello Freitas, Felipe Teixeira; Pais Ramos, Jesus; Dias Campos, Carlos Eduardo; de Souza Caldas, Paulo Cesar; Santos Bordalo, Fernanda; Amorim Ramos, Tatyana Costa; do Nascimento Pereira, Vívian; Cordeiro-Santos, Marcelo; Abdalla Santos, Joao Hugo; Coelho Motta, Glauco; Gomes, Suzie Marie; Mendes de Souza, Verena Maria; de Araujo, Wildo Navegantes

    2015-01-01

    OBJECTIVE To identify risk factors related to Mycobacterium abscessus subsp. bolletii infection during an outbreak, associated with laparoscopic surgery and to propose recommendations for preventing new cases. DESIGN A retrospective cohort study. SETTING A private hospital in Manaus, Brazil. PATIENTS A cohort of 222 patients who underwent laparoscopic surgery between July 2009 and August 2010 by a single surgical team. METHODS We collected information about the patients and the surgical procedure using a standard form. We included sex, age, and variables with P≤0.2 in the bivariate analysis in a logistic regression model. Additionally, we reviewed the procedures for reprocessing the laparoscopic surgery equipment, and the strains obtained with culture were identified by molecular methods. RESULTS We recorded 60 (27%) cases of infection. After multivariate analysis, the duration of surgery beyond 1 hour (odds ratio [OR] 2.4; 95% confidence interval [CI] 1.2-4.5), not to have been the first operated patient on a given day (OR, 2.7; 95% CI, 1.4-5.2), and the use of permanent trocar (OR, 2.2; 95% CI, 1.1-4.2) were associated with infection. We observed that the surgical team attempted to sterilize the equipment in glutaraldehyde solution when sanitary authorities had already prohibited it. Eleven strains presented 100% DNA identity with a single strain, known as BRA100 clone. CONCLUSIONS Because contaminated material can act as vehicle for infection, ensuring adequate sterilization processing of video-assisted surgery equipment was crucial to stopping this single clonal outbreak of nonturbeculous mycobacteria in Brazil.

  8. Developing a coaching mechanism for practicing surgeons.

    PubMed

    Stefanidis, Dimitrios; Anderson-Montoya, Brittany; Higgins, Robert V; Pimentel, Manuel E; Rowland, Patrick; Scarborough, Madison O; Higgins, Danelle

    2016-09-01

    While performance feedback and assessment are hallmarks of surgical training, they abruptly cease after training is completed. In their absence, performance may stagnate and poor habits persist. Our aim was to develop a coaching mechanism for practicing surgeons with feedback provision based on objective performance assessment. Technical and nontechnical intraoperative video recordings from laparoscopic or robotic cholecystectomies, colectomies, and hysterectomies were assessed by a blinded surgeon and a human factors expert, respectively. Aspects of performance in need of improvement were noted, and a coaching session was developed for feedback provision to participating surgeons. This 4-hour coaching session consisted of a didactic lecture with video review and hands-on practice using procedural and mannequin-based simulation. Thirty-two practicing surgeons (18 general; 14 gynecologists) from 6 different hospitals were assessed, and 9 of them participated in coaching. Technical aspects identified for performance improvement included suboptimal trocar placement, inadequate critical view achievement during laparoscopic cholecystectomies, poor visualization of the operating field, bimanual dexterity, and dissection techniques, while nontechnical aspects included inappropriate handling of distractions and interruptions, poor ergonomic positioning and situational awareness, and inadequate mitigation of delays. Most surgeons appropriately accomplished some of the objectives of the distraction scenario, but none was able to achieve expert levels on Fundamentals of Laparoscopy tasks. Participants perceived the coaching sessions as highly valuable. Our study identified several technical and nontechnical skill sets of practicing surgeons in need of improvement and provided support for the implementation of coaching programs for surgeons on an ongoing basis. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Redo-urethroplasty in pelvic fracture urethral distraction defect: an audit.

    PubMed

    Bhagat, Suresh K; Gopalakrishnan, Ganesh; Kumar, Santosh; Devasia, Antony; Kekre, Nitin S

    2011-02-01

    To predict the outcome of redo-urethroplasty after failed single or multiple open urethral procedures for pelvic fracture urethral distraction defects. From January 1997 to December 2006, 43 patients underwent redo-urethroplasty for pelvic fracture urethral distraction defect. Forty-one were referred from other centers. All had undergone open surgery along with an endoscopic procedure (one or more procedures in each patient) which included endoscopic internal urethrotomy, urethral stenting or urethral dilations. There were 43 men with mean age of 29 (range 11-52). Eleven had associated injuries: intraperitoneal bladder rupture (3), bladder neck (2), rectum (3), anal sphincter (2), combined bladder, rectum and anal sphincter (1). Trocar suprapubic cystostomy was performed in 22, rail-road procedures in 10 and open suprapubic cystostomy in 11 along with the management of associated injuries as immediate treatment. Of 43 patients, 28 had progressive perineal, and 12 had transpubic repair. Three patients had total bulbar necrosis, and they underwent prepuceal tube reconstruction (1) and staged substitution with BMG and standard scrotal inlay (2). Analysis of various factors like number of attempts at previous surgery and stricture length did not affect the outcome. A successful result was achieved in 36 (83.72%), improved and stable in five and failure in two. The overall result of redo-urethroplasty for pelvic fracture urethral distraction defect continues to be gratifying. Failures happen usually within the first 3 months. Substitution urethroplasty can be reserved for those who have long distraction defect. Long-term follow-up is essential using stringent criteria to measure success.

  10. Intra-operative disruptions, surgeon's mental workload, and technical performance in a full-scale simulated procedure.

    PubMed

    Weigl, Matthias; Stefan, Philipp; Abhari, Kamyar; Wucherer, Patrick; Fallavollita, Pascal; Lazarovici, Marc; Weidert, Simon; Euler, Ekkehard; Catchpole, Ken

    2016-02-01

    Surgical flow disruptions occur frequently and jeopardize perioperative care and surgical performance. So far, insights into subjective and cognitive implications of intra-operative disruptions for surgeons and inherent consequences for performance are inconsistent. This study aimed to investigate the effect of surgical flow disruption on surgeon's intra-operative workload and technical performance. In a full-scale OR simulation, 19 surgeons were randomly allocated to either of the two disruption scenarios (telephone call vs. patient discomfort). Using a mixed virtual reality simulator with a computerized, high-fidelity mannequin, all surgeons were trained in performing a vertebroplasty procedure and subsequently performed such a procedure under experimental conditions. Standardized measures on subjective workload and technical performance (trocar positioning deviation from expert-defined standard, number, and duration of X-ray acquisitions) were collected. Intra-operative workload during simulated disruption scenarios was significantly higher compared to training sessions (p < .01). Surgeons in the telephone call scenario experienced significantly more distraction compared to their colleagues in the patient discomfort scenario (p < .05). However, workload tended to be increased in surgeons who coped with distractions due to patient discomfort. Technical performance was not significantly different between both disruption scenarios. We found a significant association between surgeons' intra-operative workload and technical performance such that surgeons with increased mental workload tended to perform worse (β = .55, p = .04). Surgical flow disruptions affect surgeons' intra-operative workload. Increased mental workload was associated with inferior technical performance. Our simulation-based findings emphasize the need to establish smooth surgical flow which is characterized by a low level of process deviations and disruptions.

  11. Laparoscopic repair of Morgagni hernia and cholecystectomy in a 40-year-old male with Down's sindrome. Report of a case.

    PubMed

    De Paolis, P; Mazza, L; Maglione, V; Fronda, G R

    2007-06-01

    Morgagni-Larrey hernia (MH) is an unusual diaphragmatic hernia of the retrosternal region. Few cases of MH, treated laparoscopically, associated with Down's syndrome (DS) have been reported in literature. On October 2004, a DS 40-year-old male was admitted to our Department with mild abdominal pain and nausea. Hematochemical tests were within the normal range. Ultrasonography showed biliary sludge and multiple gallstones. Chest X-ray revealed a right-sided paracardiac mass that appeared as MH after a thoraco-abdominal computed tomography (CT). Four trocars were placed as a routinary cholecystectomy. Abdominal exploration confirmed the presence of a voluminous hernia through a wide diaphragmatic defect (12 cm) on the left side of the falciform ligament, containing the last 20 cm ileal loops and right colon with the third lateral of transverse. After retrograde cholecystectomy and reduction of the herniated ileo-colonic tract from multiple adherences, the defect was repaired with an interrupted 2/0 silk suture and then a running 2/0 polypropylene suture. Postoperative course was complicated by pulmonary edema but subsequently the patient was discharged without further complications and has no recurrence after 2 years. In conclusion, surgery is necessary for symptomatic MH and to prevent possible severe complications. We preferred laparoscopy for the reduced morbidity compared to laparotomy, even if in our case the postoperative course was not uneventful. There are still few comparative data about the modality of closure of the defect between primary repair with nonabsorbable suture material, in case of small defects, or continuous monofilament suture or prosthesis in case of large defects.

  12. Surgical navigation in urology: European perspective.

    PubMed

    Rassweiler, Jens; Rassweiler, Marie-Claire; Müller, Michael; Kenngott, Hannes; Meinzer, Hans-Peter; Teber, Dogu

    2014-01-01

    Use of virtual reality to navigate open and endoscopic surgery has significantly evolved during the last decade. Current status of seven most interesting projects inside the European Association of Urology section of uro-technology is summarized with review of literature. Marker-based endoscopic tracking during laparoscopic radical prostatectomy using high-definition technology reduces positive margins. Marker-based endoscopic tracking during laparoscopic partial nephrectomy by mechanical overlay of three-dimensional-segmented virtual anatomy is helpful during planning of trocar placement and dissection of renal hilum. Marker-based, iPAD-assisted puncture of renal collecting system shows more benefit for trainees with reduction of radiation exposure. Three-dimensional laser-assisted puncture of renal collecting system using Uro-Dyna-CT realized in an ex-vivo model enables minimal radiation time. Electromagnetic tracking for puncture of renal collecting system using a sensor at the tip of ureteral catheter worked in an in-vivo model of porcine ureter and kidney. Attitude tracking for ultrasound-guided puncture of renal tumours by accelerometer reduces the puncture error from 4.7 to 1.8 mm. Feasibility of electromagnetic and optical tracking with the da Vinci telemanipulator was shown in vitro as well as using in-vivo model of oesophagectomy. Target registration error was 11.2 mm because of soft-tissue deformation. Intraoperative navigation is helpful during percutaneous puncture collecting system and biopsy of renal tumour using various tracking techniques. Early clinical studies demonstrate advantages of marker-based navigation during laparoscopic radical prostatectomy and partial nephrectomy. Combination of different tracking techniques may further improve this interesting addition to video-assisted surgery.

  13. To evaluate the safety and efficacy of the TVT-Secur procedure in the treatment of stress urinary incontinence in women.

    PubMed

    Sandhu, J S; Karan, S C; Maiti, G D; Dudeja, Puja

    2017-01-01

    The prevalence of stress urinary incontinence (SUI) in the middle-aged Indian women is around 16%. The use of transvaginal tapes (TVTs) has revolutionised the surgical management of SUI. Patients who undergo placement of the tape via the transobturator route often complain of persistent thigh pain at the site of trocar insertion. The use of minimally invasive tapes with a single suburethral incision reduces surgical trauma by eliminating thigh incisions, while maintaining the cure achieved by conventional TVTs. The study was conducted to test the efficacy and safety of minimally invasive TVT-Secur tape placement for treatment of SUI in women. 20 women with stress incontinence were implanted with TVT-Secur tapes and followed up for a year. The objective cure rate of SUI was 85% at the end of a year. The improvement in the patient satisfaction and Incontinence-specific QOL scores, of both Urogenital Distress Inventory (UDI-6) and Incontinence Impact Questionnaire-7 (IIQ-7), was statistically significant at 95% and 99% confidence levels. There were no complaints of thigh pain; however, there were intraoperative complications in the form of bladder perforation in 5% ( n  = 1), urethral injury in 5% ( n  = 1) and urethral tape exposure in 10% ( n  = 2), at 3 months requiring tape sectioning. These cure rates and complications are comparable to the standard TVT implantations at the end of a year, without thigh pain; however, a greater number of patients and a longer follow-up is required to see whether the long-term cure is maintained or not, before recommending the same as a standard of treatment.

  14. Laparoscopic Reversal of Roux-en-Y Gastric Bypass: Technique and Utility for Treatment of Endocrine Complications

    PubMed Central

    Campos, Guilherme M.; Ziemelis, Martynas; Paparodis, Rodis; Ahmed, Muhammed; Davis, Dawn Belt

    2018-01-01

    Background The anatomical and physiological changes with Roux-en-Y gastric bypass (RYGB) may lead to uncommon but occasionally difficult to treat complications such as hyperinsulinemic hypoglycemia with neuroglycopenia and recalcitrant hypocalcemia associated to hypoparathyroidism. Medical management of these complications is challenging. Laparoscopic reversal of RYGB anatomy with restoration of pyloric function and duodenal continuity is a potential treatment. Objective To present the indications, surgical technique and clinical outcomes of laparoscopic reversal of RYGB. Setting Tertiary Academic Medical Center, United States. Methods Prospective study of consecutive patients offered laparoscopic reversal of RYGB. Results Five patients with remote laparoscopic RYGB underwent laparoscopic reversal of RYGB to normal anatomy (n=2) or modified sleeve gastrectomy (n=3). Indications were medically refractory hyperinsulinemic hypoglycemia with neuroglycopenia (n=3), recalcitrant hypocalcemia with hypoparathyroidism (n=1) and both conditions simultaneously (n=1). Prior to reversal all patients had a gastrostomy tube placed in the excluded stomach to document improvement of symptoms. Laparoscopic reversal was accomplished successfully in all patients. Three post-operative complications occurred; bleeding that required transfusion, gallstone pancreatitis and a superficial trocar site infection. Average length of stay was 3 days. At a mean follow-up of 12 months (range 3 to 22), no additional episodes of neuroglycopenia occurred, average number of hypoglycemic episodes per week decreased from 18.5±12.4 to 1.5±1.9 (p=0.05) and hypocalcemia became responsive to oral replacement therapy in both patients. Conclusions Laparoscopic reversal of RYGB to normal anatomy or modified sleeve gastrectomy is feasible and may be a therapeutic option for selected patients with medically refractory hyperinsulinemic hypoglycemia and/or recalcitrant hypocalcemia associated to

  15. Diagnostic evaluation and management of patients with rectus sheath hematoma. A retrospective study.

    PubMed

    Salemis, Nikolaos S; Gourgiotis, Stavros; Karalis, Georgios

    2010-01-01

    Rectus sheath hematoma (RSH) is an uncommon cause of acute abdominal pain. It may mimic a wide variety of intraabdominal disorders thus frequently leading to delay in treatment, increased morbidity or even in an unnecessary surgery. This is a retrospective study of 10 patients with RSH who were treated in our department over a five-year period. There were 6 (60%) men and 4 (40%) women ranging in age from 38 to 86 years, with a mean age of 57.1 years. The most common clinical presentation was a palpable abdominal mass associated with abdominal pain. Computed tomography (CT) established the diagnosis in 100% of the cases. 4 patients had type I hematoma, 3 had type II hematoma and 3 had type III hematoma. Anticoagulation therapy was the most common predisposing factor. Conservative treatment was effective in 90% of the cases and in all cases of spontaneous RSHs in patients under anticoagulation therapy. One patient, who developed a very severe RSH following an abdominal injection of low-molecular-weight heparin (LMWH), underwent surgery. All patients with type III hematoma required blood transfusion. RSH should be considered in the differential diagnosis of the elderly patients under anticoagulation therapy presenting with acute abdominal pain and a palpable mass. CT is the diagnostic modality of choice. Conservative treatment is feasible in most cases. Early diagnosis is mandatory in order to avoid morbidity or unnecessary surgery. In order to prevent a traumatic RSH, trocar insertion under direct vision during laparoscopic surgery and careful attention in the abdominal administration of LMWH are essential. Copyright (c) 2010 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  16. Evaluation of a novel continuous glucose measurement device in patients with diabetes mellitus across the glycemic range.

    PubMed

    Morrow, Linda; Hompesch, Marcus; Tideman, Ann M; Matson, Jennifer; Dunne, Nancy; Pardo, Scott; Parkes, Joan L; Schachner, Holly C; Simmons, David A

    2011-07-01

    This glucose clamp study assessed the performance of an electrochemical continuous glucose monitoring (CGM) system for monitoring levels of interstitial glucose. This novel system does not require use of a trocar or needle for sensor insertion. Continuous glucose monitoring sensors were inserted subcutaneously into the abdominal tissue of 14 adults with type 1 or type 2 diabetes. Subjects underwent an automated glucose clamp procedure with four consecutive post-steady-state glucose plateau periods (40 min each): (a) hypoglycemic (50 mg/dl), (b) hyperglycemic (250 mg/dl), (c) second hypoglycemic (50 mg/dl), and (d) euglycemic (90 mg/dl). Plasma glucose results obtained with YSI glucose analyzers were used for sensor calibration. Accuracy was assessed retrospectively for plateau periods and transition states, when glucose levels were changing rapidly (approximately 2 mg/dl/min). Mean absolute percent difference (APD) was lowest during hypoglycemic plateaus (11.68%, 14.15%) and the euglycemic-to-hypoglycemic transition (14.21%). Mean APD during the hyperglycemic plateau was 17.11%; mean APDs were 18.12% and 19.25% during the hypoglycemic-to-hyperglycemic and hyperglycemic-to-hypoglycemic transitions, respectively. Parkes (consensus) error grid analysis (EGA) and rate EGA of the plateaus and transition periods, respectively, yielded 86.8% and 68.6% accurate results (zone A) and 12.1% and 20.0% benign errors (zone B). Continuous EGA yielded 88.5%, 75.4%, and 79.3% accurate results and 8.3%, 14.3%, and 2.4% benign errors for the euglycemic, hyperglycemic, and hypoglycemic transition periods, respectively. Adverse events were mild and unlikely to be device related. This novel CGM system was safe and accurate across the clinically relevant glucose range. © 2011 Diabetes Technology Society.

  17. Evaluation of a Novel Continuous Glucose Measurement Device in Patients with Diabetes Mellitus across the Glycemic Range

    PubMed Central

    Morrow, Linda; Hompesch, Marcus; Tideman, Ann M; Matson, Jennifer; Dunne, Nancy; Pardo, Scott; Parkes, Joan L; Schachner, Holly C; Simmons, David A

    2011-01-01

    Background This glucose clamp study assessed the performance of an electrochemical continuous glucose monitoring (CGM) system for monitoring levels of interstitial glucose. This novel system does not require use of a trocar or needle for sensor insertion. Method Continuous glucose monitoring sensors were inserted subcutaneously into the abdominal tissue of 14 adults with type 1 or type 2 diabetes. Subjects underwent an automated glucose clamp procedure with four consecutive post-steady-state glucose plateau periods (40 min each): (a) hypoglycemic (50 mg/dl), (b) hyperglycemic (250 mg/dl), (c) second hypoglycemic (50 mg/dl), and (d) euglycemic (90 mg/dl). Plasma glucose results obtained with YSI glucose analyzers were used for sensor calibration. Accuracy was assessed retrospectively for plateau periods and transition states, when glucose levels were changing rapidly (approximately 2 mg/dl/min). Results Mean absolute percent difference (APD) was lowest during hypoglycemic plateaus (11.68%, 14.15%) and the euglycemic-to-hypoglycemic transition (14.21%). Mean APD during the hyperglycemic plateau was 17.11%; mean APDs were 18.12% and 19.25% during the hypoglycemic-to-hyperglycemic and hyperglycemic-to-hypoglycemic transitions, respectively. Parkes (consensus) error grid analysis (EGA) and rate EGA of the plateaus and transition periods, respectively, yielded 86.8% and 68.6% accurate results (zone A) and 12.1% and 20.0% benign errors (zone B). Continuous EGA yielded 88.5%, 75.4%, and 79.3% accurate results and 8.3%, 14.3%, and 2.4% benign errors for the euglycemic, hyperglycemic, and hypoglycemic transition periods, respectively. Adverse events were mild and unlikely to be device related. Conclusion This novel CGM system was safe and accurate across the clinically relevant glucose range. PMID:21880226

  18. Robot-assisted laparoscopic pyeloplasty: minimum 1-year follow-up

    NASA Astrophysics Data System (ADS)

    Patel, Vipul; Thaly, Rahul; Shah, Ketul

    2007-02-01

    Objectives: To evaluate the feasibility and efficacy of robotic-assisted laparoscopic pyeloplasty. Laparoscopic pyeloplasty has been shown to have a success rate comparable to that of the open surgical approach. However, the steep learning curve has hindered its acceptance into mainstream urologic practice. The introduction of robotic assistance provides advantages that have the potential to facilitate precise dissection and intracorporeal suturing. Methods: A total of 50 patients underwent robotic-assisted laparoscopic dismembered pyeloplasty. A four-trocar technique was used. Most patients were discharged home on day 1, with stent removal at 3 weeks. Patency of the ureteropelvic junction was assessed in all patients with mercaptotriglycylglycine Lasix renograms at 1, 3, 6, 9, and 12 months, then every 6 months for 1 year, and then yearly. Results: Each patient underwent a successful procedure without open conversion or transfusion. The average estimated blood loss was 40 ml. The operative time averaged 122 minutes (range 60 to 330) overall. Crossing vessels were present in 30% of the patients and were preserved in all cases. The time for the anastomosis averaged 20 minutes (range 10 to 100). Intraoperatively, no complications occurred. Postoperatively, the average hospital stay was 1.1 days. The stents were removed at an average of 20 days (range 14 to 28) postoperatively. The average follow-up was 11.7 months; at the last follow-up visit, each patient was doing well. Of the 50 patients, 48 underwent one or more renograms, demonstrating stable renal function, improved drainage, and no evidence of recurrent obstruction. Conclusions: Robotic-assisted laparoscopic pyeloplasty is a feasible technique for ureteropelvic junction reconstruction. The procedure provides a minimally invasive alternative with good short-term results.

  19. Robotics and general surgery.

    PubMed

    Jacob, Brian P; Gagner, Michel

    2003-12-01

    Robotics are now being used in all surgical fields, including general surgery. By increasing intra-abdominal articulations while operating through small incisions, robotics are increasingly being used for a large number of visceral and solid organ operations, including those for the gallbladder, esophagus, stomach, intestines, colon, and rectum, as well as for the endocrine organs. Robotics and general surgery are blending for the first time in history and as a specialty field should continue to grow for many years to come. We continuously demand solutions to questions and limitations that are experienced in our daily work. Laparoscopy is laden with limitations such as fixed axis points at the trocar insertion sites, two-dimensional video monitors, limited dexterity at the instrument tips, lack of haptic sensation, and in some cases poor ergonomics. The creation of a surgical robot system with 3D visual capacity seems to deal with most of these limitations. Although some in the surgical community continue to test the feasibility of these surgical robots and to question the necessity of such an expensive venture, others are already postulating how to improve the next generation of telemanipulators, and in so doing are looking beyond today's horizon to find simpler solutions. As the robotic era enters the world of the general surgeon, more and more complex procedures will be able to be approached through small incisions. As technology catches up with our imaginations, robotic instruments (as opposed to robots) and 3D monitoring will become routine and continue to improve patient care by providing surgeons with the most precise, least traumatic ways of treating surgical disease.

  20. Effects of preoperative ultrasound-guided transversus abdominis plane block on pain after laparoscopic surgery for colorectal cancer: a double-blind randomized controlled trial.

    PubMed

    Oh, Tak Kyu; Yim, Jiyeon; Kim, Jaehyun; Eom, Woosik; Lee, Soon Ae; Park, Sung Chan; Oh, Jae Hwan; Park, Ji Won; Park, Boram; Kim, Dae Hyun

    2017-01-01

    Although laparoscopic colorectal surgery decreases postoperative pain and facilitates a speedier recovery compared with laparotomy, postoperative pain at trocar insertion sites remains a clinical concern. The objective of this study was to assess the effects of a preoperative ultrasound-guided transversus abdominis plane (TAP) block on pain after laparoscopic surgery for colorectal cancer. In total, 58 patients scheduled to undergo laparoscopic surgery following a diagnosis of colorectal cancer were included in this study. The patients were randomized into TAP and control groups; the TAP group patients received a preoperative ultrasound-guided bilateral TAP block with 0.5 mL/kg of 0.25 % bupivacaine, while the control patients received the block with an equal amount of saline. Pain on coughing and at rest was assessed during postanesthetic recovery (PAR; 1 h after surgery) and on postoperative days (PODs) 1 (24 h), 2 (48 h), and 3 (72 h) by an investigator blinded to group allocations using the numeric rating scale (NRS). The primary outcome was pain on coughing on postoperative day (POD) 1. Fifty-five patients were included in the final analysis, including 28 in the TAP and 27 in the control groups. The pain intensity on coughing and at rest during PAR and on PODs 1, 2, and 3 showed no significant differences between groups. Furthermore, there was no significant difference in postoperative opioid consumption, sedation scores, nausea scores at the four time points, complication rates, and length of hospital stay between groups. In colorectal cancer patients undergoing laparoscopic colorectal surgery, a TAP block did not offer enough benefit for clinical efficacy in terms of postoperative pain or analgesic consumption.

  1. Single surgeon experience with robot-assisted ureteroureterostomy for pathologies at the proximal, middle, and distal ureter in adults.

    PubMed

    Lee, Ziho; Llukani, Elton; Reilly, Christopher E; Mydlo, Jack H; Lee, David I; Eun, Daniel D

    2013-08-01

    To describe our initial experience with robot-assisted ureteroureterostomy (RUU) at the proximal, middle, and distal ureter. Twelve consecutive patients underwent RUU by a single surgeon (D.D.E.) between July 2009 and November 2012. Indications included three iatrogenic injuries, two impacted stones, two ureterovaginal fistulas, two idiopathic ureteral strictures refractory to conservative treatment, one primary transitional cell carcinoma of the ureter, one colon cancer metastasis to the ureter, and one invasive endometriosis. There were two proximal, three middle, and seven distal ureteral pathologies. Tension-free anastomosis was achieved in all 12 patients. All patients with proximal and middle ureteral pathology received concomitant downward nephropexy (DN) as a standard part of RUU. Mean age of patients at the time of surgery was 52 years (range 30-69), mean body mass index was 30.0 kg/m(2) (range 21-38), mean operative room time was 190 minutes (range 104-354), mean estimated blood loss was 181 mL (range 50-400), and mean length of excised ureter on pathologic analysis was 2.0 cm (range 1.0-4.5). There was one intraoperative complication in which liver and gallbladder laceration occurred during trocar placement. Mean length of hospital stay was 1.4 days (range 1-5), and there were no postoperative complications. Mean follow up was 10 months (range 3-36). One patient had a ureteral stricture recurrence at 7 months postoperatively that led to renal unit loss and eventual nephrectomy. RUU is feasible, safe, and demonstrates good outcomes for pathologies at the proximal, middle, and distal ureter. Concomitant DN during RUU may assist in achieving a tension-free anastomosis for proximal and middle ureteral repairs.

  2. Mixed reality for robotic treatment of a splenic artery aneurysm.

    PubMed

    Pietrabissa, Andrea; Morelli, Luca; Ferrari, Mauro; Peri, Andrea; Ferrari, Vincenzo; Moglia, Andrea; Pugliese, Luigi; Guarracino, Fabio; Mosca, Franco

    2010-05-01

    Techniques of mixed reality can successfully be used in preoperative planning of laparoscopic and robotic procedures and to guide surgical dissection and enhance its accuracy. A computer-generated three-dimensional (3D) model of the vascular anatomy of the spleen was obtained from the computed tomography (CT) dataset of a patient with a 3-cm splenic artery aneurysm. Using an environmental infrared localizer and a stereoscopic helmet, the surgeon can see the patient's anatomy in transparency (augmented or mixed reality). This arrangement simplifies correct positioning of trocars and locates surgical dissection directly on top of the aneurysm. In this way the surgeon limits unnecessary dissection, leaving intact the blood supply from the short gastric vessels and other collaterals. Based on preoperative planning, we were able to anticipate that the vascular exclusion of the aneurysm would result in partial splenic ischemia. To re-establish the flow to the spleen, end-to-end robotic anastomosis of the splenic artery with the Da Vinci surgical system was then performed. Finally, the aneurysm was fenestrated to exclude arterial refilling. The postoperative course was uneventful. A control CT scan 4 weeks after surgery showed a well-perfused and homogeneous splenic parenchyma. The final 3D model showed the fenestrated calcified aneurysm and patency of the re-anastomosed splenic artery. The described technique of robotic vascular exclusion of a splenic artery aneurysm, followed by re-anastomosis of the vessel, clearly demonstrates how this technology can reduce the invasiveness of the procedure, obviating an otherwise necessary splenectomy. Also, the use of intraoperative mixed-reality technology proved very useful in this case and is expected to play an increasing role in the operating room of the future.

  3. Pure retroperitoneal natural orifice translumenal endoscopic surgery (NOTES) transvaginal nephrectomy using standard laparoscopic instruments: a safety and feasibility study in a porcine model.

    PubMed

    Wei, Dechao; Han, Yili; Li, Mingchuan; Wang, Yongxing; Chen, Yatong; Luo, Yong; Jiang, Yongguang

    2016-06-11

    Among the different organs used for NOTES (natural orifice translumenal endoscopic surgery) technique, the transvaginal approach may be the optimal choice because of a simple and secure closure of colpotomy site. Pure and hybrid NOTES transvaginal operations were routinely performed via transperitoneal access. In this study, we investigate the safety and feasibility of pure retroperitoneal natural orifice translumenal endoscopic surgery (NOTES) transvaginal nephrectomy using conventional laparoscopic techniques in a porcine model. Six female pigs, weighing an average of 30 kg, were used in this study. Under general anesthesia, pure retroperitoneal NOTES transvaginal nephrectomy was conducted using standard laparoscopic instruments. Posterolateral colpotomy was performed, and the incision was enlarged laterally using blunt dissection and pneumatic dilation. A single-port device was inserted to construct the operative channel. The retroperitoneal space was created using sharp and blunt dissection under endoscopic guidance up to the level of the kidney. Dissection and removal of the kidney were performed according to standard surgical procedure, and the colpotomy site was closed using interrupted sutures. The survival and complications were observed 1 week postoperatively. Our results showed that two cases failed because of peritoneal rupture. One case was successful, but required the assistance of an extra 5 mm laparoscopic trocar inserted in the flank. Three cases of pure retroperitoneal NOTES transvaginal nephrectomy were completed, and survived 1 week after the operation. In these three cases, no intra- or postoperative complications were observed. All findings confirmed the safety and feasibility of the retroperitoneal pure retroperitoneal NOTES transvaginal nephrectomy using standard laparoscopic instruments, which suggested the possibility of clinical application in human beings in the future.

  4. Port-site metastasis after laparoscopic surgery for colorectal cancer--still a real concern? Case report and review of the literature.

    PubMed

    Bărbulescu, M; Alecu, L; Boeţi, P; Popescu, I

    2012-01-01

    The recently published long-term oncological results of the large multicentric randomized prospective trials, such as COST, COLOR, and UK MRC CLASICC, have diminished once more the initial skepticism from the mid '90s, regarding the safety of laparoscopic approach for colorectal cancer surgery. The actual incidence of port-site metastases (PMSs) in the laparoscopic surgery for colorectal cancer is just arround 1%, being statistically simmilar to the wound metastases after open colorectal surgery. We followed up a series of 122 laparoscopic-assisted resections for colorectal adenocarcinoma, 49 for rectal cancer and 73 for colon cancer. The operations were performed at the Center of Digestive Diseases and Liver Transplantation, Fundeni Clinical Institute, Bucharest, Romania, between 1st January 2002 and 31st december 2008. There was only one case of PMS (0.81%). A 83-year old man developed a recurrent parietal tumor on the site of extraction minilaparotomy, 4 months after laparoscopic-assisted right hemicolectomy for a Dukes C, poorly differentiated (G3) adenocarcinoma of the cecum. We have reviewed the scientific relevant literature regarding the incidence and multi-factor etiology of PMSs in the laparoscopic surgery for colorectal cancer as well as the methods suggested for prevention of parietal tumour dissemination to the trocar or wound sites. PMSs consecutive to laparoscopic surgery for colorectal cancer are no longer a big concern enough to contraindicate this beneficial surgery for oncological reasons. However, PMSs continue to represent a reality which must be taken into consideration by any laparoscopic surgeon. There are different prevention measures that should be applied for reducing the occurence of this possible complication.

  5. Minilaparoscopy-assisted transumbilical laparoscopic cholecystectomy.

    PubMed

    Lima, Geraldo José DE Souza; Leite, Rodrigo Fabiano Guedes; Abras, Gustavo Munayer; Pires, Livio José Suretti; Castro, Eduardo Godoy

    2016-01-01

    The role of laparoscopy in the modern surgery era is well established. With the prospect of being able to improve the already privileged current situation, new alternatives have been proposed, such as natural orifice endoscopic surgery (NOTES), the method for single transumbilical access (LESS - Laparo-endoscopic single-site surgery) and minilaparoscopy (MINI). The technique proposed by the authors uses a laparoscope with an operative channel like the flexible endoscope used in NOTES. All operative times are carried out through the umbilical trocar as in LESS, and assisted by a minilaparoscopy grasper. This new technic combines, and results from, the rationalization of technical particularities and synergy of these three approaches, seeking to join their advantages and minimize their disadvantages. RESUMO O papel da videolaparoscopia na era moderna da cirurgia encontra-se bem estabelecido. Com a perspectiva de ser possível melhorar a já privilegiada situação atual, novas alternativas têm sido propostas, como a cirurgia por orifícios naturais (NOTES), o método por acesso único transumbilical (LESS - Laparo-endoscopic single-site surgery) e a minilaparoscopia (MINI). A técnica proposta pelos autores utiliza-se de óptica com canal de trabalho como o endoscópio flexível do NOTES, executa-se todos os tempos operatórios pelo trocarte umbilical, como no LESS, e é assistido por pinça de minilaparoscopia. Esta nova técnica combina e resulta da racionalização de particularidades técnicas e do sinergismo destas três abordagens, buscando agregar suas vantagens e minimizar as suas desvantagens.

  6. Intelligent viewpoint selection for efficient CT to video registration in laparoscopic liver surgery.

    PubMed

    Robu, Maria R; Edwards, Philip; Ramalhinho, João; Thompson, Stephen; Davidson, Brian; Hawkes, David; Stoyanov, Danail; Clarkson, Matthew J

    2017-07-01

    Minimally invasive surgery offers advantages over open surgery due to a shorter recovery time, less pain and trauma for the patient. However, inherent challenges such as lack of tactile feedback and difficulty in controlling bleeding lower the percentage of suitable cases. Augmented reality can show a better visualisation of sub-surface structures and tumour locations by fusing pre-operative CT data with real-time laparoscopic video. Such augmented reality visualisation requires a fast and robust video to CT registration that minimises interruption to the surgical procedure. We propose to use view planning for efficient rigid registration. Given the trocar position, a set of camera positions are sampled and scored based on the corresponding liver surface properties. We implement a simulation framework to validate the proof of concept using a segmented CT model from a human patient. Furthermore, we apply the proposed method on clinical data acquired during a human liver resection. The first experiment motivates the viewpoint scoring strategy and investigates reliable liver regions for accurate registrations in an intuitive visualisation. The second experiment shows wider basins of convergence for higher scoring viewpoints. The third experiment shows that a comparable registration performance can be achieved by at least two merged high scoring views and four low scoring views. Hence, the focus could change from the acquisition of a large liver surface to a small number of distinctive patches, thereby giving a more explicit protocol for surface reconstruction. We discuss the application of the proposed method on clinical data and show initial results. The proposed simulation framework shows promising results to motivate more research into a comprehensive view planning method for efficient registration in laparoscopic liver surgery.

  7. The 3DBiopsy Prostate Biopsy System: Preclinical Investigation of a Needle, Actuator, and Specimen Collection Device Allowing Sampling of Individualized Prostate Lengths Between 20 and 60 mm.

    PubMed

    Stone, Nelson N; Mouraviev, Vladimir; Schechter, David; Lucia, M Scott; Smith, Elizabeth E; Arangua, Paul; Hoenemeyer, John; Rosa, Jim; Bawa, Rajan; Crawford, E David

    2017-09-01

    To increase the likelihood of detecting anterior cancers within the prostate and provide a specimen that spans the length of the gland. Newly designed 17- and 15-gauge (G) biopsy needles, a variable actuator, and an integrated pathology system intended for the longer cores were developed and tested for this purpose. Testing was performed comparing 2 common cannula tip grinds, a Vet-point (sharp tip) and a Menghini-point (atraumatic tip), and were tested against 18-G Bard Monopty in porcine kidney. A variable actuator was developed to fire the needle 20-60 mm and tested in cadaver prostates. The aggregate firings for 3 different shot lengths comparing the Vet- with the Menghini-tip cannulas demonstrated 91% vs 85.2% fill (length of specimen/length of core bed, P = .007). A 15-G trocar needle with the Vet-tip cannula also had the best performance, with an aggregate standard deviation of 6.4% across 3 firing ranges and a minimum to maximum specimen length of 81%-105% of potential fill. Cadaver testing with the Vet-tip needles in the actuator for the transrectal (17-G) and transperineal (15-G) biopsies demonstrated mean fills of 93.3% and 76.5%, respectively. The new transrectal ultrasound needle obtained a 2-fold increase in specimen length over the standard Bard device (P <.001). Longer and consistent cores were obtained using the new biopsy needles. Combined with an adjustable actuator, the physician can obtain specimens that include peripheral and anterior zone tissue in 1 core. Determination of cancer location on the longer specimens could enhance focal therapy planning. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects

    PubMed Central

    Mota, Francisco Hidelbrando Alves; Sávio, Luis Felipe; Sakata, Rafael Eiji; Ivanovic, Renato Fidelis; da Silva, Marco Antonio Nunes; Maia, Ronaldo Soares; Passerotti, Carlo Camargo

    2018-01-01

    ABSTRACT Introduction Robot-Assisted Single Site Radical Nephrectomy (RASS-RN) has been reported by surgeons in Europe and United States (1–3). To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. Case A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Results Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3 cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using an 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Discussion Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2). Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. Conclusion RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology. PMID:29039889

  9. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects.

    PubMed

    Mota Filho, Francisco Hidelbrando Alves; Sávio, Luis Felipe; Sakata, Rafael Eiji; Ivanovic, Renato Fidelis; da Silva, Marco Antonio Nunes; Maia, Ronaldo; Passerotti, Carlo

    2018-01-01

    Robot-Assisted Single Site Radical Nephrectomy (RASS-RN) has been reported by surgeons in Europe and United States (1-3). To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using na 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2). Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology. Copyright® by the International Brazilian Journal of Urology.

  10. Single site multiport umbilical laparoscopic appendicectomy versus conventional multiport laparoscopic appendicectomy in acute settings

    PubMed Central

    Yadav, SP

    2014-01-01

    Introduction Although conventional multiport laparoscopic appendicectomy (CMLA) is preferred for managing acute appendicitis, the recently developed transumbilical laparoscopic approach is rapidly gaining popularity. However, its wide dissemination seems restricted by technical/technological issues. In this regard, a newly developed method of single site multiport umbilical laparoscopic appendicectomy (SMULA) was compared prospectively with CMLA to assess the former’s efficacy and the technical advantages in acute scenarios. Methods Overall, 430 patients were studied: 212 in the SMULA group and 218 in the CMLA group. The same surgeon performed all the procedures using routine laparoscopic instruments. The SMULA technique entailed three ports inserted directly at the umbilical mound through three distinct strategically placed mini-incisions without raising the umbilical flap. The CMLA involved the traditional three-port technique. Results Both groups were comparable in terms of demographic criteria, indications for surgery, intraoperative blood loss, time to ambulation, length of hospital stay and umbilical morbidity. Although the mean operative time was marginally longer in the SMULA group (43.35 minutes, standard deviation [SD]: 21.16 minutes) than in the CMLA group (42.28 minutes, SD: 21.41 minutes), this did not reach statistical significance. Conversely, the mean pain scores on day 0 and the cosmetic outcomes differed significantly and favoured the SMULA technique. None of the patients developed port site hernias over the follow-up period (mean 2.9 years). Conclusions The favourable outcomes for the SMULA technique are likely to be due to the three small segregated incisions at one place and better trocar ergonomics. The SMULA technique is safe in an acute setting and may be considered of value among the options for transumbilical appendicectomy. PMID:25198978

  11. Staple Line Reinforcement with Stitch in Laparoscopic Sleeve Gastrectomies. Is It Useful or Harmful?

    PubMed

    Albanopoulos, Konstantinos; Tsamis, Dimitrios; Arapaki, Aggeliki; Kleidi, Eleftheria; Zografos, Georgios; Leandros, Emmanouil

    2015-07-01

    Reinforcement of the staple line in laparoscopic sleeve gastrectomy (LSG) is a practice that leads to less morbidity, but equivocal results have been reported in the literature. This is a prospective randomized study comparing two groups of patients who underwent LSG. In one group LSG was performed with a running absorbable suture placement at the staple line. In the other group the running suture was not placed. General data of the patients, as well as intraoperative and postoperative data, were gathered and statistically analyzed. Overall, 146 patients were subjected to LSG. In 84 patients a running suture was placed, and in 62 patients no suture was placed. No significant differences were found between the two groups in demographic data. No significant differences were found also in the intraoperative data, such as number of trocars, number and type of cartridges, drain placement, and operative time (45±21 versus 40±20 minutes, respectively; P<.05). Intraoperative complications were significantly more in the group with the suture placement (33.3% versus 16.1%, respectively; P<.05). Hematomas developed intraoperatively in more patients after the placement of the running suture (9.5% versus 0.0%, respectively; P<.05). Postoperatively, there was no significant difference in morbidity between the two groups (8.3% versus 9.7%, respectively; P>.05). After this randomized study, final conclusions about the efficacy of this running suture to the staple line cannot be made. To the contrary, problems seem to exist after such reinforcement of the staple line, such as hematomas. Dealing with possible leaks and hemorrhage of the staple line is also problematic after placement of the running suture.

  12. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

    PubMed Central

    2018-01-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity (“water seal”) drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. PMID:29372629

  13. Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators

    PubMed Central

    Kulshrestha, Vikas

    2008-01-01

    Background: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail. Materials and Methods: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature. Results: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10), 14 Gustilo type 2 (n=14), and type3 (n=6) cases. 6 cases (20%) had clamp site infection, 2 cases (6.7%) had deep infection, and in 28 cases (93%) the fracture healed and consolidated well. Conclusion: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection. PMID:19753227

  14. Transcontinental telementoring with pediatric surgeons: proof of concept and technical considerations.

    PubMed

    Ponsky, Todd A; Bobanga, Iuliana D; Schwachter, Marc; Stathos, Theodore H; Rosen, Michael; Parry, Robert; Nalugo, Margaret; Rothenberg, Steven S

    2014-12-01

    To evaluate different technologies that can facilitate telementoring in a variety of pediatric surgical procedures. Two different telementoring technologies were used to provide two-way audio and visual communication between experienced pediatric surgeon mentors located in another city and less experienced trainees performing a surgical procedure. The first technology consisted of store-bought equipment that connected the operating room laparoscope to a Skype™ (Microsoft, Redmond, WA) connection (used in 1 case), whereas the second was a proprietary telementoring robot, Karl Storz Endoscopy-America, Inc. VisitOR1(®) (Karl Storz GmbH & Co. KG, Tuttlingen, Germany) (used in 5 cases). The procedures included a video-assisted thoracic surgery lower lobectomy, a temporary and two permanent gastric stimulator placements, and two laparoscopic inguinal hernia repairs and were performed by pediatric surgeons (3 cases), a pediatric gastroenterologist (1 case), and a general surgeon (2 cases) under the guidance of pediatric surgeon mentors. All procedures were completed successfully in a time-efficient manner, without loss of transmission and without complications. Although the Skype technology was less costly, it lacked telestrator capacity and was not adequately secure. The VisitOR1 telementoring robot enabled high-resolution video communication, had telestrator capacity, and allowed pointing during the procedure. The mentors assisted with trocar placement, modifying the surgical technique, identifying planes of dissection, and indicating locations of device and suture placement. Telementoring is a useful adjunct in the field of pediatric surgery that can aid in the transfer of surgical skills remotely and shorten the time to implementation of new surgical techniques into practice. Optimal telementoring technology should have a secure wireless connection, high video resolution, and minimal bandwidth latency.

  15. Ocular perfusion pressure control during pars plana vitrectomy: testing a novel device.

    PubMed

    Rossi, Tommaso; Querzoli, Giorgio; Gelso, Aldo; Angelini, Giampiero; Rossi, Alessandro; Corazza, Paolo; Landi, Laura; Telani, Serena; Ripandelli, Guido

    2017-12-01

    To study the efficacy of a novel device intended to control infusion pressure based on mean ocular perfusion pressure (MOPP) during pars plana vitrectomy (PPV). An arm blood pressure cuff connected to a vitrectomy machine calculated mean arterial pressure (MAP), while a pressure sensor close to the infusion trocar measured intraocular pressure (IOP). MOPP was calculated in real time in 36 consecutive patients undergoing PPV, who were divided into two groups. The device lowered IOP every time that calculated MOPP fell below 30 mmHg in the Control ON group (18 patients), while no action was taken in the Control OFF group (18 patients). Baseline IOP and blood pressure were similar between groups. The Control ON group had significantly lower average intraoperative IOP (30.5 ± 2.1 vs. 35.9 ± 6.9 mmHg; p = 0.002) and higher MOPP (56.4 ± 5.9 vs. 49.7 ± 6.1 mmHg) than the Control OFF group. The Control ON group also spent less time at MOPP < 10 mmHg and < 30 mmHg: 0 vs. 3.40 ± 2.38 min (p < 0.001) and 9.91 ± 7.15 vs. 16.13 ± 8.12 min (p = 0.02), respectively. The MOPP control device effectively maintained lower IOP and higher MOPP throughout surgery. It also helped avoid dangerous IOP peaks and MOPP dips, allowing patients to spend less time at MOPP of < 10 and < 30 mmHg.

  16. Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model

    PubMed Central

    Soltz, Barbara A.; Stadler, Istvan; Soltz, Robert

    2009-01-01

    Background and Objectives: Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. Methods: Anesthetized 20-kg to 25-kg female Yorkshire pigs underwent laparoscopy performed using a 3-trocar technique. Peritoneal incisions were made and pockets created in the preperitoneal space for mesh placement. Parietex TEC mesh segments embedded in 60% collagen-solder were soldered to the muscle surface by using a prototype laser (1.45µ, 4.5W CW, 5mm spot, and 55°C set temperature) and custom laparoscopic handpiece. Parietex TEC mesh segments (Control) were affixed to the muscle with fibrin sealant (Tisseel). Peritoneal closure was with staples (Control) or by soldering collagen embedded Vicryl mesh segments over the peritoneal incision (Mesh/TAPP). Segments were inserted using a specially designed introducer. Animals were recovered and underwent second-look laparoscopy at 6 weeks postimplantation. Mesh sites were harvested after animals were euthanized. Results: The mesh-solder constructs were easily inserted and affixed in the TAPP approach. Tisseel tended to drip during application, particularly in vertical and ventral locations. Postoperative healing was similar to Control segments in all cases. Mesh/TAPP closures healed without scarring or adhesion formation. Discussion and Conclusion: Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce use of staples for laparoscopic mesh fixation and peritoneal closure. Laser-assisted mesh fixation and peritoneal closure is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted. PMID:19660214

  17. Robot-assisted real-time magnetic resonance image-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    Real-time magnetic resonance imaging (rtMRI)-guided transcatheter aortic valve replacement (TAVR) offers improved visualization, real-time imaging, and pinpoint accuracy with device delivery. Unfortunately, performing a TAVR in a MRI scanner can be a difficult task owing to limited space and an awkward working environment. Our solution was to design a MRI-compatible robot-assisted device to insert and deploy a self-expanding valve from a remote computer console. We present our preliminary results in a swine model. We used an MRI-compatible robotic arm and developed a valve delivery module. A 12-mm trocar was inserted in the apex of the heart via a subxiphoid incision. The delivery device and nitinol stented prosthesis were mounted on the robot. Two continuous real-time imaging planes provided a virtual real-time 3-dimensional reconstruction. The valve was deployed remotely by the surgeon via a graphic user interface. In this acute nonsurvival study, 8 swine underwent robot-assisted rtMRI TAVR for evaluation of feasibility. Device deployment took a mean of 61 ± 5 seconds. Postdeployment necropsy was performed to confirm correlations between imaging and actual valve positions. These results demonstrate the feasibility of robotic-assisted TAVR using rtMRI guidance. This approach may eliminate some of the challenges of performing a procedure while working inside of an MRI scanner, and may improve the success of TAVR. It provides superior visualization during the insertion process, pinpoint accuracy of deployment, and, potentially, communication between the imaging device and the robotic module to prevent incorrect or misaligned deployment. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  18. Robotic single-site pelvic lymphadenectomy.

    PubMed

    Tateo, Saverio; Nozza, Arrigo; Del Pezzo, Chiara; Mereu, Liliana

    2014-09-01

    To examine the feasibility of performing pelvic lymphadenectomy with robotic single site approach. Recent papers described the feasibility of robotic-single site hysterectomy [1-3] for benign and malign pathologies but only with the development of new single site 5mm instruments as the bipolar forceps, robotic single site platform can be safely utilized also for lymphadenectomy. A 65 year-old, multiparous patient with a body mass index of 22.5 and diagnosed with well differentiated adenocarcinoma of the endometrium underwent a robotic single-site peritoneal washing, total hysterectomy, bilateral adnexectomy and pelvic lymphadenectomy. The procedure was performed using the da Vinci Si Surgical System (Intuitive Surgical, Sunnyvale, CA) through a single 2,5 cm umbilical incision, with a multi-channel system and two single site robotic 5mm instruments. A 3-dimensional, HD 8.5mm endoscope and a 5mm accessory instrument were also utilized. Type I lymphonodes dissection for external iliac and obturator regions was performed [4]. Total operative time was 210 min; incision, trocar placement and docking time occurring in 12 min. Total console time was 183 min, estimated blood loss was 50 ml, no intra-operative or post-operative complications occurred. Hospital discharge occurred on post operative day 2 and total number of lymphnodes removed was 33. Difficulties in term of instrument's clashing and awkward motions have been encountered. Robotic single-site pelvic lymphadenectomy using bipolar forceps and monopolar hook is feasible. New developments are needed to improve surgical ergonomics and additional studies should be performed to explore possible benefits of this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Intimal re-layering technique for type A acute aortic dissection-reconstructing the intimal layer continuity to induce remodeling of the false channel.

    PubMed

    Neri, Eugenio; Tucci, Enrico; Tommasino, Giulio; Guaccio, Giulia; Ricci, Carmelo; Lucatelli, Pierleone; Cini, Marco; Ceresa, Roberto; Benvenuti, Antonio; Muzzi, Luigi

    2018-01-01

    Residual false channel is common after repair of type A acute aortic dissection (TAAAD). Starting from our recent series of TAAAD patients we carried out a retrospective analysis, regarding the failure of primary exclusion at the time of the initial operation. We classified the location of the principal entry tears perfusing the residual false channel. The proposed technique represents our attempt to correct the mechanism of false channel perfusion during primary repair. We describe a new technique designed to address some limitations of standard hemiarch aortic replacement. Its goal are: (I) to reinforce the intimal layer at the arch level; (II) to eliminate inter-luminal communications at the arch level using suture lines around the arch vessels; (III) to provide an elephant trunk configuration for further interventions. Between August 2016 and January 2018, 11 patients underwent emergency surgery using this technique; 7 were men; the median age was 74 years. All patients were treated using systemic circulatory arrest under moderate hypothermia (26 °C) and selective cerebral perfusion. All patients had supra-coronary repair; 1 patient had aortic valve replacement + CABG. In the first two patients a manual suture around supra-aortic trunks was used; the subsequent seven patients were treated with a mechanical suture bladeless device. CT scan follow up was performed in all survivors with controls before discharge 3 months and 1 year after operation. No patient died in the operating room and no neurologic deficit was observed in this initial experience. One patient died in POD 5th for low cardiac output syndrome. Median ICU stay was 3 days (IQR, 2-6 days). Hospital mean length of stay was 15.2±8 days. Median cardiopulmonary bypass time was 130 min (IQR, 110-141 min); median arrest time for re-layering was 17 min (IQR, 16-20 min); median total arrest was 36 min (IQR, 29-39 min). Distal aortic anastomosis was performed in zone 0 in 4 patients, zone 1, with

  20. Intimal re-layering technique for type A acute aortic dissection—reconstructing the intimal layer continuity to induce remodeling of the false channel

    PubMed Central

    Tucci, Enrico; Tommasino, Giulio; Guaccio, Giulia; Ricci, Carmelo; Lucatelli, Pierleone; Cini, Marco; Ceresa, Roberto; Benvenuti, Antonio; Muzzi, Luigi

    2018-01-01

    Background Residual false channel is common after repair of type A acute aortic dissection (TAAAD). Starting from our recent series of TAAAD patients we carried out a retrospective analysis, regarding the failure of primary exclusion at the time of the initial operation. We classified the location of the principal entry tears perfusing the residual false channel. The proposed technique represents our attempt to correct the mechanism of false channel perfusion during primary repair. We describe a new technique designed to address some limitations of standard hemiarch aortic replacement. Its goal are: (I) to reinforce the intimal layer at the arch level; (II) to eliminate inter-luminal communications at the arch level using suture lines around the arch vessels; (III) to provide an elephant trunk configuration for further interventions. Methods Between August 2016 and January 2018, 11 patients underwent emergency surgery using this technique; 7 were men; the median age was 74 years. All patients were treated using systemic circulatory arrest under moderate hypothermia (26 °C) and selective cerebral perfusion. All patients had supra-coronary repair; 1 patient had aortic valve replacement + CABG. In the first two patients a manual suture around supra-aortic trunks was used; the subsequent seven patients were treated with a mechanical suture bladeless device. CT scan follow up was performed in all survivors with controls before discharge 3 months and 1 year after operation. Results No patient died in the operating room and no neurologic deficit was observed in this initial experience. One patient died in POD 5th for low cardiac output syndrome. Median ICU stay was 3 days (IQR, 2–6 days). Hospital mean length of stay was 15.2±8 days. Median cardiopulmonary bypass time was 130 min (IQR, 110–141 min); median arrest time for re-layering was 17 min (IQR, 16–20 min); median total arrest was 36 min (IQR, 29–39 min). Distal aortic anastomosis was performed in zone 0 in

  1. Laparoscopic upper pole heminephroureterectomy in children: Seven-year experience.

    PubMed

    Marte, Antonio; Papparella, Alfonso; Pintozzi, Lucia

    2015-01-01

    Minimally invasive surgery is the current approach to perform heminephroureterectomy (HN) in children. This can be obtained through a transperitoneal (TP) or a retroperitoneal approach. Here, we report our experience using a TP approach. From 2005 to 2014, 22 TP laparoscopic upper poles HN were performed at our institution. There were nine girls and 13 boys aged between 20 months and 6 years (mean age 3.9). Eight patients were diagnosed prenatally, 17 patients presented with urinary tract infection (UTI) and three with vomiting and failure to thrive. The indication for HN was reflux nephropathy and UTI in non-functioning upper pole in 19 patients and cystic dysplasia in 1 patient. The surgical technique involved the following steps: Cystoscopic recognition; positioning of 3-4 trocar (right HN); identification of the kidney (detachment of the colon); isolation and low ligation of the dilated ureter; decrossing from renal vessels; section of the parenchyma by LigaSure; haemostasis with clips and LigaSure; drain. The mean operative time was 154 min (range: 81-220 min). All patients were discharged from the 2 nd to 4 th day. Neither major complication nor conversion was recorded. 1 patient presented leakage of urine for 7 days from the drainage which resolved spontaneously. At ultrasound follow-up, 5 patients showed a secondary perirenal cyst, 2-5 cm diameter that resolved spontaneously. The results indicate that laparoscopic upper pole heminephrectomy is the treatment of choice in cases of non-functioning dilated lower segments of duplicated kidneys. The use of laparoscopic approach offers a good working space, a good visual control of the vessels and allows a very low isolation of the ureteral stump which counterbalance the peritoneal violation.

  2. Laparoscopic upper pole heminephroureterectomy in children: Seven-year experience

    PubMed Central

    Marte, Antonio; Papparella, Alfonso; Pintozzi, Lucia

    2015-01-01

    Background: Minimally invasive surgery is the current approach to perform heminephroureterectomy (HN) in children. This can be obtained through a transperitoneal (TP) or a retroperitoneal approach. Here, we report our experience using a TP approach. Materials and Methods: From 2005 to 2014, 22 TP laparoscopic upper poles HN were performed at our institution. There were nine girls and 13 boys aged between 20 months and 6 years (mean age 3.9). Eight patients were diagnosed prenatally, 17 patients presented with urinary tract infection (UTI) and three with vomiting and failure to thrive. The indication for HN was reflux nephropathy and UTI in non-functioning upper pole in 19 patients and cystic dysplasia in 1 patient. The surgical technique involved the following steps: Cystoscopic recognition; positioning of 3-4 trocar (right HN); identification of the kidney (detachment of the colon); isolation and low ligation of the dilated ureter; decrossing from renal vessels; section of the parenchyma by LigaSure; haemostasis with clips and LigaSure; drain. Results: The mean operative time was 154 min (range: 81-220 min). All patients were discharged from the 2nd to 4th day. Neither major complication nor conversion was recorded. 1 patient presented leakage of urine for 7 days from the drainage which resolved spontaneously. At ultrasound follow-up, 5 patients showed a secondary perirenal cyst, 2-5 cm diameter that resolved spontaneously. Conclusion: The results indicate that laparoscopic upper pole heminephrectomy is the treatment of choice in cases of non-functioning dilated lower segments of duplicated kidneys. The use of laparoscopic approach offers a good working space, a good visual control of the vessels and allows a very low isolation of the ureteral stump which counterbalance the peritoneal violation. PMID:26712285

  3. Decreased recurrence rate in the laparoscopic herniorraphy in children: comparison between two techniques.

    PubMed

    Marte, Antonio; Sabatino, Maria D; Borrelli, Micaela; Parmeggiani, Pio

    2009-04-01

    The laparoscopic herniorraphy in children is still associated to a high recurrence rate. The aim of this study was to assess whether the addition of the lateral incision of the sac to the sole suture of the inner inguinal ring could reduce the recurrence rate. A retrospective review was performed of the collected data of 248 laparoscopic inguinal hernia repairs in 224 children (175 males, 49 females) between 8 months and 11 years of age (mean age, 5 years; median, 4) in our institution from January 2004 to December 2007. The hernia was unilateral in 204 patients (133 on the right side, 71 on the left) and bilateral in 20 patients. A 5-mm umbilical camera port for a 0-degree laparoscopic optics and two operative 2- or 3-mm reusable trocars inserted in the lower right and left quadrants of the abdominal wall were utilized. In a group of 123 patients, the inner inguinal ring was closed, adopting a W-shaped suture (inguinal ring suture; IRS). In the other group of 101 patients, a lateral incision of the sac of 1-2 cm was carried out before the W-shaped suture of the inner inguinal ring (inguinal ring incision suture; IRIS). At a mean follow-up of 24 months (range, 6-36), 5 of 133 (3.76%) hernias recurred between 6 and 12 months after surgery in the IRS group. In the IRIS group, none of the patients presented with recurrence. The rate of recurrences in the two groups was compared and analyzed with the x2 test. The resulting difference was statistically significant (P < 0.05). In our experience, the incision of the peritoneum lateral to the internal inguinal ring and the W-shaped suture, compared to the sole W-shaped suture, is safe and effective in preventing hernia recurrence.

  4. Closure of ascites leaks with fibrin glue injection in patients with end-stage liver disease.

    PubMed

    Sadik, Karim W; Laibstain, Sarah; Northup, Patrick G; Kashmer, David; Schmitt, Timothy M; Bonatti, Hugo J R

    2011-09-01

    Ascites leaks (AL) in patients with end-stage liver disease (ESLD) are associated with significant morbidity and mortality regardless if they are medically or surgically managed. In a pilot study, 14 ESLD patients with AL underwent treatment with fibrin glue injection around the leak after failing conservative therapy. The end point of this study was the cessation of AL in the short term and the maintenance of a leak-free abdomen in the long term, allowing for medical optimization of the patients. Median age of the 10 men and 4 women was 50 (range 26-67) years. Underlying ESLDs were chronic hepatitis C (n=5), alcoholic LD (n=2), cryptogenic cirrhosis (n=2), and miscellaneous (n=5). There were six leaking incisions posthernia repair (three umbilical and three inguinal), two leaking/ruptured umbilical hernias, four leaking paracentesis sites, one leaking Jackson-Pratt (JP) drain canal, and one leaking laparoscopic trocar site. Average AL volume per day was 1000 (range 400-2000) mL. All leaks were immediately resolved with a 3-5 mL fibrin glue injection. Five recurred and required a second injection (four within 24 hours). Mental status improved in 7 patients (West Haven Criteria: grade II to I [n=6], grade III to I [n=1]). Median model of end-stage liver disease scores improved from 23 (range 8-33) to 20 (range 14-26). There were no infections, bleeds, or other injection-related complications. Average follow-up for these patients was 441.6 days (range 2-852). Five patients underwent liver transplant (LT) median 15 (range 4-270) days postinjection; 2 of them died. Another 3 patients died (2 from sepsis and 1 from metastatic cancer). Fibrin glue injection for the control of AL is a simple and safe bedside procedure that quickly controls AL, allowing for patient recovery in anticipation of further care.

  5. Pediatric femoral hernia in the laparoscopic era.

    PubMed

    Aneiros Castro, Belén; Cano Novillo, Indalecio; García Vázquez, Araceli; López Díaz, María; Benavent Gordo, María Isabel; Gómez Fraile, Andrés

    2017-12-20

    Femoral hernia is a rare and often misdiagnosed condition in childhood. The aim of our study was to demonstrate that the laparoscopic approach improves diagnostic accuracy and offers a safe and effective treatment. A retrospective study of 687 pediatric patients who underwent laparoscopic inguinal hernia repair from January 2000 to December 2015 was performed. Femoral hernias were identified in 16 patients (2.3%). The right side was affected in 10 cases (62.5%), the left side in 5 (31.2%), and 1 case was bilateral (6.2%). The mean age of patients was 8.00 ± 3.81 years, and there was a male predominance. Preoperative diagnosis was femoral hernia in eight cases (50%) and indirect inguinal hernia in the remaining eight (50%). Seven children (43.8%) presented with hernia recurrence after having undergone an open ipsilateral indirect hernia repair. A modified laparoscopic McVay technique was performed in 12 cases (70.6%). An epigastric artery injury by trocar occurred in one patient. All operations were completed laparoscopically. The mean surgical time was 45.6 ± 22.9 min for unilateral cases and 110 ± 10.0 min for bilateral cases. No immediate postoperative complications were noted. The mean postoperative hospital stay was 0.6 ± 0.4 days. No recurrence was observed after a median follow-up of 11 years (range, 4-16 years). Femoral hernia is a rare pathology in pediatric patients that is often difficult to diagnose. The laparoscopic approach is effective in the diagnosing and treating these hernias, and it allows for the simultaneous repair of multiple groin defects. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  6. Combined open and laparoscopic approach to chronic pain following open inguinal hernia repair.

    PubMed

    Rosen, M J; Novitsky, Y W; Cobb, W S; Kercher, K W; Heniford, B Todd

    2006-03-01

    Chronic groin pain is the most common long-term complication after open inguinal hernia repair. Traditional surgical management of the associated neuralgia consists of injection therapy followed by groin exploration, mesh removal, and nerve transection. The resultant hernia defect may be difficult to repair from an anterior approach. We evaluate the outcomes of a combined laparoscopic and open approach for the treatment of chronic groin pain following open inguinal herniorrhaphy. All patients who underwent groin exploration for chronic neuralgia after a prior open inguinal hernia repair were prospectively analyzed. Patient demographics, type of prior hernia repair, and prior nonoperative therapies were recorded. The operation consisted of a standard three trocar laparoscopic transabdominal preperitoneal hernia repair, followed by groin exploration, mesh removal, and nerve transection. Outcome measures included recurrent groin pain, numbness, hernia recurrence, and complications. Twelve patients (11 male and 1 female) with a mean age of 41 years (range 29-51) underwent combined laparoscopic and open treatment for chronic groin pain. Ten patients complained of unilateral neuralgia, one patient had bilateral complaints, and one patient complained of orchalgia. All patients failed at least two attempted percutaneous nerve blocks. Prior repairs included Lichtenstein (n=9), McVay (n=1), plug and patch (n=1), and Shouldice (n=1). There were no intraoperative complications or wound infections. With a minimum of 6 weeks follow up, all patients were significantly improved. One patient complained of intermittent minor discomfort that required no further therapy. Two patients had persistent numbness in the ilioinguinal nerve distribution but remained satisfied with the procedure. A combined laparoscopic and open approach for postherniorrhaphy groin pain results in good to excellent patient satisfaction with no perioperative morbidity. It may be the preferred technique for the

  7. Single site and conventional totally extraperitoneal techniques for uncomplicated inguinal hernia repair: A comparative study.

    PubMed

    de Araújo, Felipe Brandão Corrêa; Starling, Eduardo Simão; Maricevich, Marco; Tobias-Machado, Marcos

    2014-10-01

    To demonstrate the feasibility of endoscopic extraperitoneal single site (EESS) inguinal hernia repair and compare it outcomes with the conventional totally extraperitoneal (TEP) technique. TEP inguinal hernia repair is a widely accepted alternative to conventional open technique with several perioperative advantages. Transumbilical laparoendoscopic singlesite surgery (LESS) is an emerging approach and has been reported for a number of surgical procedures with superior aesthetic results but other advantages need to be proven. Thirty-eight uncomplicated inguinal hernias were repaired by EESS approach between January 2010 and January 2011. All procedures were performed through a 25 cm infraumbilical incision using the Alexis wound retractor attached to a surgical glove and three trocars. Body mass index, age, operative time, blood loss, complications, conversion rate, analgesia requirement, hospital stay, return to normal activities and patient satisfaction with aesthetic results were analysed and compared with the last 38 matched-pair group of patients who underwent a conventional TEP inguinal hernia repair by the same surgeon. All procedures were performed successfully with no conversion. In both unilateral and bilateral EESS inguinal repairs, the mean operative time was longer than conventional TEP (55± 20 vs. 40± 15 min, P = 0.049 and 70± 15 vs. 55± 10 min, P = 0.014). Aesthetic result was superior in the EESS group (2.88± 0.43 vs. 2.79± 0.51, P = 0.042). There was no difference between the two approaches regarding blood loss, complications, hospital stay, time until returns to normal activities and analgesic requirement. EESS inguinal hernia repair is safe and effective, with superior cosmetic results in the treatment of uncomplicated inguinal hernias. Other advantages of this new technique still need to be proven.

  8. A new minimally invasive technique for the repair of femoral hernia in children: about 13 laparoscopic repairs in 10 patients.

    PubMed

    Matthyssens, Lucas E M; Philippe, Paul

    2009-05-01

    Femoral hernias in children are rare and often misdiagnosed. The classic treatment is through an open anterior approach. Since the advent of laparoscopic treatment of inguinal hernia in children, laparoscopy has been proposed to offer an accurate diagnosis and treatment, especially in case of recurrent hernia or bilateral disease. This review was undertaken to report our experience with the primary laparoscopic diagnosis and treatment of pediatric femoral hernias and to investigate its safety and feasibility. All cases of pediatric femoral hernia in a consecutive series of children treated laparoscopically for groin hernias in a single institution over a 7-year period (2001-2007) were identified and studied for patient characteristics, presentation, pre- and perioperative findings, details of the operative repair, and postoperative outcome. Out of a prospectively studied series of 462 laparoscopic pediatric inguinal hernia repairs in 389 patients, 13 femoral hernias were treated in 10 patients (6 boys), with a mean age of 71/2 years (range, 1.7-12). The preoperative diagnosis of femoral hernia was accurate in 7 patients. Seven femoral hernias were exclusively right sided; 3 were bilateral. All 13 femoral hernias were successfully treated by a standardized transabdominal laparoscopic approach with the use of three 3.5-mm trocars. All patients were treated in a day care setting. No postoperative complications occurred. No recurrences were seen until the present time, with a mean follow-up of 31/2 years. Laparoscopy provides a straightforward, accurate diagnosis for the rare and often missed pediatric femoral hernias. The new technique described offers a safe and efficient minimally invasive anatomical repair of the crural orifice in children, even when not suspected preoperatively. The laparoscopic diagnosis of 13 femoral hernias from a cohort of 462 laparoscopic groin hernia repairs (2.8%) may suggest a higher prevalence rate of this unusual type of hernia in

  9. Outcome of percutaneous continuous drainage of psoas abscess: A clinically guided technique.

    PubMed

    Dave, Bharat R; Kurupati, Ranganatha Babu; Shah, Dipak; Degulamadi, Devanand; Borgohain, Nitu; Krishnan, Ajay

    2014-01-01

    Percutaneous aspiration of abscesses under ultrasonography (USG) and computer tomography (CT) scan has been well described. With recurrence rate reported as high as 66%. The open drainage and percutaneous continuous drainage (PCD) has reduced the recurrence rate. The disadvantage of PCD under CT is radiation hazard and problems of asepsis. Hence a technique of clinically guided percutaneous continuous drainage of the psoas abscess without real-time imaging overcomes these problems. We describe clinically guided PCD of psoas abscess and its outcome. Twenty-nine patients with dorsolumbar spondylodiscitis without gross neural deficit with psoas abscess of size >5 cm were selected for PCD. It was done as a day care procedure under local anesthesia. Sequentially, aspiration followed by guide pin-guided trocar and catheter insertion was done without image guidance. Culture sensitivity was done and chemotherapy initiated and catheter kept till the drainage was <10 ml for 48 hours. Outcome assessment was done with relief of pain, successful abscess drainage and ODI (Oswestry Disability Index) score at 2 years. PCD was successful in all cases. Back and radicular pain improved in all cases. Average procedure time was 24.30 minutes, drain output was 234.40 ml, and the drainage duration was 7.90 days. One patient required surgical stabilisation due to progression of the spondylodiscitis resulting in instability inspite of successful drainage of abscess. Problems with the procedure were noticed in six patients. Multiple attempts (n = 2), persistent discharge (n = 1) for 2 weeks, blocked catheter (n = 2) and catheter pull out (n = 1) occurred with no effect on the outcome. The average ODI score improved from 62.47 to 5.51 at 2 years. Clinically guided PCD is an efficient, safe and easy procedure in drainage of psoas abscess.

  10. Laparoscopic transabdominal preperitoneal inguinal hernia repair using needlescopic instruments: a 15-year, single-center experience in 317 patients.

    PubMed

    Wada, Hidetoshi; Kimura, Taizo; Kawabe, Akihiro; Sato, Masanori; Miyaki, Yuichirou; Tochikubo, Junpei; Inamori, Kouji; Shiiya, Norihiko

    2012-07-01

    Laparoscopic inguinal hernia repair is associated with a decrease in postoperative pain, shortened hospital stay, earlier return to normal activity, and decrease in chronic pain. Moreover, laparoscopic surgery performed with needlescopic instruments has more advantages than conventional laparoscopic surgery. However, there are few reports of large-scale laparoscopic transabdominal preperitoneal inguinal hernia repair using needlescopic instruments (nTAPP). This report reviews our experiences with 352 nTAPP in 317 patients during the 15-year period from April 1996 to April 2011. We performed nTAPP as the method of choice in 88.5% of all patients presenting with inguinal hernia. To perform the nTAPP, 3-mm instruments were used. A 5-mm laparoscope was inserted from the umbilicus, and surgical instruments were inserted through 5- and 3-mm trocars. After reduction of the hernia sac and dissection of the preperitoneal space, we placed polyester mesh or polypropylene soft mesh with staple fixation. The peritoneum was closed with 3-0 silk interrupted sutures. The mean operative time was 102.9 min for unilateral hernias and 155.8 min for bilateral hernias. There was no conversion to open repair. Forty-three patients (13.6%) used postoperative analgesics, and the mean frequency of use was 0.5 times. Regarding intraoperative complications, we observed one bladder injury, but no bowel injuries or major vessel injuries. Postoperative complications occurred in 32 patients (10.1%). One patient with a retained lipoma required reoperation. There was no incidence of chronic pain or mesh infection. The operative time for experienced surgeons (≥ 20 repairs) was significantly shorter than that of inexperienced surgeons (< 20 repairs; P < 0.05). The nTAPP was a safe and useful technique for inguinal hernia repair. Large prospective, randomized controlled trials will be required to establish the benefit of nTAPP.

  11. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.

    PubMed

    Porcel, José M

    2018-04-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  12. Robotic transanal endoscopic microsurgery: technical details for the lateral approach.

    PubMed

    Buchs, Nicolas C; Pugin, François; Volonte, Francesco; Hagen, Monika E; Morel, Philippe; Ris, Frederic

    2013-10-01

    Transanal endoscopic microsurgery is a minimally invasive approach reserved for the resection of selected rectal tumors. However, this approach is technically demanding. Although robotic technology may overcome the limitations of this approach, the system can be difficult to dock, especially in the lithotomy position. The study aim is thus to report the technical details of robotic transanal endoscopic microsurgery with the use of a lateral approach. This study is a prospective evaluation of robotic transanal endoscopic microsurgery in a single tertiary institution, under a protocol approved by our local ethics committee. Patients underwent a routine mechanical bowel preparation and were placed in the left or right lateral position according to the tumor location. A circular anal dilatator was used together with the glove port technique. The robotic system was then docked over the hip. A 30° optic and 2 articulated instruments were used with an additional assistant trocar. The tumor excision was realized with an atraumatic grasper and an articulated cautery hook, and the defect was closed with barbed continuous stiches in each case. The primary outcome was the safety and feasibility of the procedure. Three patients underwent a robotic transanal endoscopic microsurgery with the use of the lateral approach. Mean operative time was 110 minutes, including 20 minutes for the docking of the robot. There was 1 intraoperative complication (a pneumoperitoneum without intraabdominal lesion) and no postoperative complications. Mean hospital stay was 3 days. Margins were negative in all the cases. The study was limited by the small number of patients. Robotic transanal endoscopic microsurgery with use of the lateral approach is feasible and may facilitate the local resection of small lesions of the mid and lower rectum. It might assume an important place in sphincter-preserving surgery, especially for selected and early rectal cancer (see Video, Supplemental Digital Content 1

  13. Incisional hernia prevention using a cyanoacrilate-fixed retrofascial mesh.

    PubMed

    Hoyuela, Carlos; Juvany, Montserrat; Trias, Miquel; Ardid, Jordi; Martrat, Antoni

    2018-01-01

    The rate of incisional hernia in high-risk patients (obesity, cancer, etc.) is high, even in laparoscopic surgery. The aim of this study is to evaluate the safety of the use of cyanoacrylate fixed prophylactic meshes in the assistance incision in overweight or obese patients undergoing laparoscopic colorectal surgery. A prospective, non-randomized cohort study of patients undergoing elective laparoscopic resection for colorectal cancer between January 2013 and March 2016 was performed. Those with a body mass index greater than 25kg / m 2 were evaluated to implant a prophylactic meshes fixed with cyanoacrylate (Histoacryl®) as reinforcement of the assistance incision. 52 patients were analyzed (mean body mass index: 28.4±2kg / m 2 ). Prophylactic meshes was implanted in 15 patients. The time to put the mesh in place was always less than 5minutes. There was no significant difference in wound infection rate (12% vs. 10%). No mesh had to be explanted. Although the mean follow-up was shorter (14.1±4 vs. 22.3±9 months), there were no incisional hernia in the mesh group. On the other hand, in the non-mesh group, 1 acute evisceration (2.7%) and 4 incisional hernia of the assistance incision were observed (10.8%). There were no significant differences between groups regarding trocar incisional hernia (6.6 vs. 5.4%). The implantation of a reinforcement prophylactic mesh in overweight or obese patients undergoing laparoscopic colorectal surgery is safe and seems to reduce the short-term rate of incisional hernia. Fixation with cyanoacrylate is a rapid method that facilitates the procedure without additional complications. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Effects of elevated artificial pneumoperitoneum pressure on invasive blood pressure and levels of blood gases.

    PubMed

    Hypolito, Octavio; Azevedo, João Luiz; Gama, Fernanda; Azevedo, Otavio; Miyahira, Susana Abe; Pires, Oscar César; Caldeira, Fabiana Alvarenga; Silva, Thamiris

    2014-01-01

    to evaluate the clinical, hemodynamic, gas analysis and metabolic repercussions of high transient pressures of pneumoperitoneum for a short period of time to ensure greater security for introduction of the first trocar. sixty-seven patients undergoing laparoscopic procedures were studied and randomly distributed in P12 group: n=30 (intraperitoneal pressure [IPP] 12mmHg) and P20 group: n=37 (IPP of 20mmHg). Mean arterial pressure (MAP) was evaluated by catheterization of the radial artery; and through gas analysis, pH, partial pressure of oxygen (PaO2), partial pressure of CO2 (PaCO2), bicarbonate (HCO3) and alkalinity (BE) were evaluated. These parameters were measured in both groups at time zero before pneumoperitoneum (TP0); at time 1 (TP1) when IPP reaches 12mmHg in both groups; at time 2 (TP2) after five min with IPP=12mmHg in P12 and after 5min with IPP=20mmHg at P20; and at time 3 (TP3) after 10min with IPP=12mmHg in P12 and with return of IPP from 20 to 12mmHg, starting 10min after TP1 in P20. Different values from those considered normal for all parameters assessed, or the appearance of atypical organic phenomena, were considered as clinical changes. there were statistically significant differences in P20 group in MAP, pH, HCO3 and BE, but within normal limits. No clinical and pathological changes were observed. high and transient intra-abdominal pressure causes changes in MAP, pH, HCO3 and BE, but without any clinical impact on the patient. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  15. A financial analysis of operating room charges for robot-assisted gynaecologic surgery: Efficiency strategies in the operating room for reducing the costs

    PubMed Central

    Zeybek, Burak; Öge, Tufan; Kılıç, Cemil Hakan; Borahay, Mostafa A.; Kılıç, Gökhan Sami

    2014-01-01

    Objective To analyse the steps taking place in the operating room (OR) before the console time starts in robot-assisted gynaecologic surgery and to identify potential ways to decrease non-operative time in the OR. Material and Methods Thirteen consecutive robotic cases for benign gynaecologic disease at the Department of Obstetrics and Gynecology at University of Texas Medical Branch (UTMB) were retrospectively reviewed. The collected data included the specific terms ‘Anaesthesia Done’ (step 1), ‘Drape Done’ (step 2), and ‘Trocar In’ (step 3), all of which refer to the time before the actual surgery began and OR charges were evaluated as level 3, 4, and 5 for open abdominal/vaginal hysterectomy, laparoscopic hysterectomy, and robot-assisted hysterectomy, respectively. Results The cost of the OR for 0–30 minutes and each additional 30 minutes were $3,693 and $1,488, $4,961 and $2,426, $5,513 and $2,756 in level 3, 4, and 5 surgeries, respectively. The median time for step 1 was 12.1 min (5.25–23.3), for step 2 was 19 (4.59–44) min, and for step 3 was 25.3 (16.45–45) min. The total median time until the actual operation began was 54.58 min (40–100). The total cost was $6948.7 when the charge was calculated according to level 4 and $7771.1 when the charge was calculated according to level 5. Conclusion Robot-assisted surgery is already ‘cost-expensive’ in the preparation stage of a surgical procedure during anaesthesia induction and draping of the patient because of charging levels. Every effort should be made to shorten the time and reduce the number of instruments used without compromising care. (J Turk Ger Gynecol Assoc 2014; 15: 25–9) PMID:24790513

  16. Liquid-injection for preperitoneal dissection of transabdominal preperitoneal (TAPP) inguinal [corrected] hernia repair.

    PubMed

    Mizota, Tomoko; Watanabe, Yusuke; Madani, Amin; Takemoto, Norihiro; Yamada, Hidehisa; Poudel, Saseem; Miyasaka, Yuji; Kurashima, Yo

    2015-03-01

    The creation of an adequate peritoneal flap during laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair, while avoiding injuring surrounding structures can be technically challenging. Liquid infiltration of the preperitoneal space can help facilitate dissection and avoid inadvertent injuries. We describe a novel technique for TAPP inguinal hernia repair using liquid-injection for preperitoneal [corrected] dissection and report our initial experience. TAPP inguinal hernia repair using a liquid-injection technique during preperitoneal dissection was performed by a single surgical resident without prior TAPP repair experience from July 2013 to January 2014. After trocar placement, 60 mL of 0.3 % lidocaine with 1:300,000 dilution of epinephrine was injected percutaneously using a blunt needle under laparoscopic visualization into the preperitoneal space to assist with the dissection and parietalization of the vas deferens, spermatic vessels, and epigastric vessels. The initial peritoneal incision is performed at the lateral side of the inguinal canal, followed by blunt dissection of the preperitoneal space. Eleven patients (median age: 69; 8 male) with a total of 12 inguinal hernias underwent a TAPP repair using a liquid-injection preperitoneal dissection technique. Ten patients had unilateral hernias (4 indirect, 6 direct), and one patient had bilateral direct hernias. The median operative time, median injection time, and median dissection time were 116, 3.5, and 42 min, respectively. Estimated blood loss was less than 10 mL for all cases. No intraoperative injuries, conversions to open repair, or 30-day postoperative complications occurred. There were no hernia recurrences after a median follow-up of 143 days. Our preliminary experience suggests that liquid-injection to assist preperitoneal dissection during TAPP inguinal hernia repair appears to be safe and feasible. This novel method facilitates the dissection of spermatic cord structures, and

  17. A new suturing instrument that allows the use of microsuture at laparoscopy.

    PubMed

    McComb, P F

    1992-04-01

    A surgeon at University Hospital-Shaughnessy Site in Vancouver, British Columbia in Canada has used a new suturing instrument that enters the peritoneal cavity to permit microsutures of size 6-0 or less and 75 cm in length during laparoscopy. Surgeons can use this instrument to perform female sterilizations as well as removal of the gall gladder and appendix and repair of the bowel, bladder, and ureteric injuries. As of April 1992, the suturing instrument was not yet commercially available. It consists of a partial hollow 30 cm x 2 mm (inside diameter) tube with the end that does not enter the peritoneal cavity being occluded. The suturing instrument enters the peritoneal cavity via a standard 5 mm deflection valved trocar sleeve with a 3 mm reduction sleeve or with a 3 mm inside diameter occlusive rubber washer instead of the standard 5 mm washer. The suture must have sufficient tensile strength and have low coefficients for static and for sliding surface frictions. Once the suture and needle are inside the body, forceps which have entered via another cannula detach them from the suturing instrument. A 3 mm laproscopic needle driver replaces the suturing instrument at this point. The surgeon guides the needle through the intended tissues and then withdrawn with the needle driver through the 5 mm sleeve. The surgeon ties the knot outside the body and slides it down the length of the suture to apply it to the tissue. He/she repeats this 1 more time. Scissors inserted through the other opening then cut the suture. Once mastered, this process takes only a few minutes to complete. In all 11 cases or restoration of uterine tube patency done by the surgeon in Vancouver using the new technique, tubal patency has not been hindered. 2 assessed sterilization reversals have been successful.

  18. Laparoendoscopic transgastric histoacryl injection of gastric varices: a new surgical approach.

    PubMed

    Kassem, Mohamed I; El-Haddad, Hani M; El-Bahrawi, Hassan A

    2013-02-01

    Gastric varices (GVs) are a common finding in Egyptian patients with portal hypertension due to cirrhosis or schistosomal hepatic fibrosis. These patients present with an acute attack or history of hematemesis. Endoscopic histoacryl injection is the standard treatment in Egypt; however, because of technical difficulties it is possible to inject only a little amount of this material, as it may endanger the channels of the flexible endoscope. We thought of a new surgical laparoendoscopic technique to obviate the need for repeated endoscopies and complete obliteration of GVs. This study was conducted on 20 patients with portal hypertension and GVs. After the patient was placed under general anesthesia, a small gastrostomy was done in the anterior gastric wall through which a 10-mm trocar was inserted for the laparoscopic camera. Injection of GVs was done via a spinal needle or a central venous line needle inserted directly. Injection of an adequate amount of histoacryl was done under direct vision. This study was conducted from July 2009 to August 2011 on 20 patients with GVs. The age range was from 22 to 56 years, with a mean age of 39.8±7.85 years. There were 14 men (70%) and 6 women (30%). Fourteen patients (70%) showed complete obliteration of GVs after one session of treatment, whereas 6 patients (30%) had unsatisfactory results and were subjected to another session. GVs were completely obliterated after the second session in 4 patients. Two cases of recurrence of GVs were operated on. This new technique enabled us to inject GVs with a suitable amount of glue material under direct vision without harming the endoscope. Use of this procedure is recommended in patients fit for surgery and those who had failed endoscopic injection sclerotherapy.

  19. The Effect of Product Safety Courses on the Adoption and Outcomes of LESS Surgery.

    PubMed

    Toomey, Paul G; Ross, Sharona B; Choung, Edward; Donn, Natalie; Vice, Michelle; Luberice, Kenneth; Albrink, Michael; Rosemurgy, Alexander S

    2015-01-01

    As technology in surgery evolves, the medical instrument industry is inevitability involved in promoting the use and appropriate (ie, effective and safe) application of its products. This study was undertaken to evaluate industry-supported product safety courses in laparoendoscopic single-site (LESS) surgery, by using the metrics of surgeons' adoption of the technique, safety of the procedure, and surgeons' perception of the surgery. LESS surgery courses that involved didactic lectures, operative videos, operation observation, collaborative learning, and simulation, were attended by 226 surgeons. With Florida Hospital Tampa Institutional Review Board approval, the surgeons were queried before and immediately after the course, to assess their attitudes toward LESS surgery. Then, well after the course, the surgeons were contacted, repeatedly if necessary, to complete questionnaires. Before the course, 82% of the surgeons undertook more than 10 laparoscopic operations per month. Immediately after the course, 86% were confident that they were prepared to perform LESS surgery. Months after the course, 77% of the respondents had adopted LESS surgery, primarily cholecystectomy; 59% had added 1 or more trocars in 0-20% of their procedures; and 73% held the opinion that operating room observation was the most helpful learning experience. Complications with LESS surgery were noted 12% of the time. Advantages of the technique were better cosmesis (58%) and patient satisfaction (38%). Disadvantages included risk of complications (37%) and higher technical demand (25%). Seventy-eight percent viewed LESS surgery as an advancement in surgical technique. In multifaceted product safety courses, operating room observation is thought to provide the most helpful instruction for those wanting to undertake LESS surgery. The procedure has been safely adopted by surgeons who frequently perform laparoscopies. The tradeoff is in performing a more difficult technique to obtain better

  20. Occult Radiographically Evident Port-Site Hernia After Robot-Assisted Urologic Surgery: Incidence and Risk Factors.

    PubMed

    Christie, Matthew C; Manger, Jules P; Khiyami, Abdulaziz M; Ornan, Afshan A; Wheeler, Karen M; Schenkman, Noah S

    2016-01-01

    Laparoscopic trocar-site hernias (TSH) are rare, with a reported incidence of 1% or less. The incidence of occult radiographically evident hernias has not been described after robot-assisted urologic surgery. We evaluated the incidence and risk factors of this problem. A single-institution retrospective review of robot-assisted urologic surgery was performed from April 2009 to December 2012. Patients with preoperative and postoperative CT were included for analysis. Imaging was reviewed by two radiologists and one urologist. One hundred four cases were identified, including 60 partial nephrectomy, 38 prostatectomy, and 6 cystectomy. Mean age was 58 years and mean body mass index (BMI) was 29 kg/m(2). The cohort was 77% male. Ten total hernias were identified by CT in 8 patients, 2 of which were clinically evident hernias. Excluding these two hernias, occult port-site hernias were identified radiographically in seven patients. Per-patient incidence of occult TSH was 6.7% (7/104), and per-port incidence was 1.4% (8/564). All hernias were midline and 30% contained bowel. Eight of the 10 occurred at 12 mm sites (p = 0.0065) and 3 of the 10 occurred at extended incisions. Age, gender, BMI, smoking status, diabetes mellitus, immunosuppressive drug therapy, ASA score, procedure, blood loss, prior abdominal surgery, and history of hernia were not significant risk factors. Specimen size >40 g (p = 0.024) and wound infection (p = 0.0052) were significant risk factors. While the incidence of clinically evident port-site hernia remains low in robot-assisted urologic surgery, the incidence of CT-detected occult hernia was 6.7% in this series. These occurred most often in sites extended for specimen extraction and at larger port sites. This suggests more attention should be paid to fascial closure at these sites.

  1. Laparoscopic subtotal colectomy with antiperistaltic cecorectal anastomosis: a new step in the treatment of slow-transit constipation.

    PubMed

    Marchesi, Federico; Percalli, Luigi; Pinna, Ferdinando; Cecchini, Stefano; Ricco', Matteo; Roncoroni, Luigi

    2012-06-01

    Subtotal colectomy with antiperistaltic cecorectal anastomosis (SCCRA) has proved to be an effective alternative to total colectomy for the treatment of severe slow-transit constipation. The laparoscopic approach has made this procedure even more attractive. This is the first controlled trial on laparoscopic SCCRA. The study compares the laparoscopic and the open approach. Since 2001, all SCCRAs have been performed laparoscopically at our institution. Only severely symptomatic patients are offered surgery, after stringent patient selection. Laparoscopic SCCRA was performed following the same steps that we first described for the open approach, by utilizing a five-trocar technique. Outcome parameters were prospectively collected every 3 and 6 months. Wexner constipation and incontinence scales (WCS, WI) and gastrointestinal quality of life index (GIQLI) were adopted for functional results. We conducted a case-control study of 15 consecutive patients who underwent laparoscopic SCCRA (VL) and 15 patients previously operated on by the open approach (Op) to compare postoperative and functional outcomes. The VL group had better postoperative outcomes (pain, ileus) while complication rates were similar. Resolution of constipation was impressive in both groups, with no significant difference at follow-up. The VL group presented with a higher number of bowel movements at 3 months (3.8 vs. 2.8, p = 0.039), resulting in a significantly higher incontinence rate at 3 months (WI 6.4 vs. 2.73, p = 0.004), although the difference was no longer significant at 1-year follow-up. The quality of life was good for both groups; the VL group showed a significant improvement at 1-year follow-up (64.18 vs. 114.79, p < 0.01). Laparoscopic SCCRA confirmed the good functional results of the open approach, with no increase in morbidity rate and a faster postoperative recovery. An early higher incontinence rate did not affect quality of life.

  2. An Endovascular Cannulation Needle with an Internal Wire for the Fragmentation of Thrombi in Retinal Vein Occlusion

    PubMed Central

    Asami, Tetsu; Kaneko, Hiroki; Miyake, Kensaku; Ota, Ichiro; Miyake, Goichiro; Kato, Seiichi; Yasuda, Shunsuke; Iwase, Takeshi; Ito, Yasuki; Terasaki, Hiroko

    2016-01-01

    Purpose We report a newly developed device to fragment thrombi in retinal vein occlusion. Methods The new instrument consists of a 23-gauge (G) pipe and a 37-G needle with an internal wire. A total of 40 porcine eyes were used; 20 eyes for experiments in the branch retinal vein (BRV group) and 20 eyes for experiments in the central retinal vein (CRV group). We placed 25-G 3-port trocars, and core vitrectomy was performed. Another 23-G scleral incision was performed for insertion of the needle. The needle pierced the retinal vein at a distance of three- to four- or one-disc diameters from the optic disc (BRV or CRV group, respectively), and the internal wire was advanced toward the disc. The success rates of needle piercing and cannulation of the internal wire were recorded in each group. In the CRV group, the cannulation was deemed successful when the tip reached inside the optic disc. Real-time optical coherence tomography imaging also was performed using the Zeiss Rescan 700 device in porcine eyes. Histologic examination of the retinal vessel inserted with the internal wire was performed. Results The success rates of needle piercing into the BRV and CRV were 85% and 95%, respectively. The success rates of cannulation of the internal wire into the BRV and CRV were 85% and 0%, respectively. The process of cannulation was recorded successfully with the Rescan 700. Histologic examination showed no damages to the endothelial cell layer. Conclusions The needle and internal wire intended to be used for recanalization of BRV occlusion were successfully pierced and cannulated into the BRV. Translational Relevance This newly developed device could become a treatment modality for retinal vein occlusion to fragment thrombi that present treatment methods cannot reach and remove directly. PMID:27730009

  3. No benefit of ultrasound-guided transversus abdominis plane blocks over wound infiltration with local anaesthetic in elective laparoscopic colonic surgery: results of a double-blind randomized controlled trial.

    PubMed

    Rashid, A; Gorissen, K J; Ris, F; Gosselink, M P; Shorthouse, J R; Smith, A D; Pandit, J J; Lindsey, I; Crabtree, N A

    2017-07-01

    Advances in laparoscopic techniques combined with enhanced recovery pathways have led to faster recuperation and discharge after colorectal surgery. Peripheral nerve blockade using transversus abdominis plane (TAP) blocks reduce opioid requirements and provide better analgesia for laparoscopic colectomies than do inactive controls. This double-blind randomized study was performed to compare TAP blocks using bupivacaine with standardized wound infiltration with local anaesthetic (LA). Seventy-one patients were randomized to receive either TAP block or wound infiltration. The TAP blocks were performed by experienced anaesthetists who used ultrasound guidance to deliver 40 ml of 0.25% bupivacaine post-induction into the transverse abdominis plane. In the control group, 40 ml of 0.25% bupivacaine was injected around the trocar and the extraction site by the surgeon. Both groups received patient-controlled analgesia (PCA) with intravenous morphine. Patients and nursing staff assessed pain scores 6, 12, 24 and 48 h after surgery. The primary outcome was overall morphine use in the first 48 h. Of the 71 patients, 20 underwent a right hemicolectomy and 51 a high anterior resection. The modified intention-to-treat analysis showed no significant differences in overall morphine use [47.3 (36.2-58.5) mg vs 46.7 (36.2-57.3) mg; mean (95% CI), P = 0.8663] in the first 48 h. Pain scores were similar at 6, 12, 24 and 48 h. No differences were found regarding time to mobilization, resumption of diet and length of hospital stay. In elective laparoscopic colectomies, standardized wound infiltration with LA has the same analgesic effect as TAP blocks post-induction using bupivacaine at 48 h. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  4. Preliminary Face and Construct Validation Study of a Virtual Basic Laparoscopic Skill Trainer

    PubMed Central

    Sankaranarayanan, Ganesh; Lin, Henry; Arikatla, Venkata S.; Mulcare, Maureen; Zhang, Likun; Derevianko, Alexandre; Lim, Robert; Fobert, David; Cao, Caroline; Schwaitzberg, Steven D.; Jones, Daniel B.

    2010-01-01

    Abstract Background The Virtual Basic Laparoscopic Skill Trainer (VBLaST™) is a developing virtual-reality–based surgical skill training system that incorporates several of the tasks of the Fundamentals of Laparoscopic Surgery (FLS) training system. This study aimed to evaluate the face and construct validity of the VBLaST™ system. Materials and Methods Thirty-nine subjects were voluntarily recruited at the Beth Israel Deaconess Medical Center (Boston, MA) and classified into two groups: experts (PGY 5, fellow and practicing surgeons) and novice (PGY 1–4). They were then asked to perform three FLS tasks, consisting of peg transfer, pattern cutting, and endoloop, on both the VBLaST and FLS systems. The VBLaST performance scores were automatically computed, while the FLS scores were rated by a trained evaluator. Face validity was assessed using a 5-point Likert scale, varying from not realistic/useful (1) to very realistic/useful (5). Results Face-validity scores showed that the VBLaST system was significantly realistic in portraying the three FLS tasks (3.95 ± 0.909), as well as the reality in trocar placement and tool movements (3.67 ± 0.874). Construct-validity results show that VBLaST was able to differentiate between the expert and novice group (P = 0.015). However, of the two tasks used for evaluating VBLaST, only the peg-transfer task showed a significant difference between the expert and novice groups (P = 0.003). Spearman correlation coefficient analysis between the two scores showed significant correlation for the peg-transfer task (Spearman coefficient 0.364; P = 0.023). Conclusions VBLaST demonstrated significant face and construct validity. A further set of studies, involving improvement to the current VBLaST system, is needed to thoroughly demonstrate face and construct validity for all the tasks. PMID:20201683

  5. Laparoscopic repair of inguinal hernias using an intraperitoneal onlay mesh technique and a Parietex composite mesh fixed with fibrin glue (Tissucol). Personal technique and preliminary results.

    PubMed

    Olmi, Stefano; Scaini, Alberto; Erba, Luigi; Bertolini, Aimone; Croce, Enrico

    2007-11-01

    Laparoscopic repair of inguinal hernias is usually achieved by totally extraperitoneal (TEP) or transabdominal preperitoneal (TAPP) techniques. The intraperitoneal onlay mesh (IPOM) could be an interesting alternative as it is much easier to perform and faster to execute. This technique is subject to correct selection of indications and to demonstration of its safety. From January 2003 to January 2006 we performed 61 laparoscopic hernia procedures on 60 selected patients (60 males with a mean age of 60 and mean weight of 76 kg) with an IPOM technique combining the Parietex composite mesh (12 cm circular model) and a fibrin glue (Tissucol) for its fixation. The glue was diluted to increase fixation time and applied to the mesh prior to positioning on the hernia defect. Mean operative time was 10 minutes. Mean hernia diameter was 2.5 cm (+/- 0.8 cm). 10 hernias were direct, 51 were indirect and 10 out of 61 were recurrent. We did not convert any of the laparoscopic procedures. Mean hospital stay was one day; mean recovery time for working and general physical activities was five days. Patients were checked after one week, 1-3-6 months and 1-2 years. Average follow up time was 23.7 months. 1.6 % of patients showed short-term complications: one trocar site haematoma. No additional complications were reported; particularly, we had no recurrence, no seroma, no mesh migration, and no bowel obstruction or fistula. Results of this study show intraperitoneal (IP) tolerance to this kind of mesh and the safety of its fixation with Tissucol. The absence of recurrence and complications could be a good reason to extend the indication of IPOM hernia repair. However, these preliminary results should be confirmed by longer follow-up.

  6. [Laparoscopic promontofixation].

    PubMed

    Romero Selas, E; Mugnier, C; Piechaud, P T; Gaston, R; Hoepffner, J-L; Hanna, S; Cusomano, S

    2010-11-01

    The pathology of the pelvic floor, including the urinary incontinence, the anal incontinence and the genital prolapse, is very dominant, concerning approximately a third of the adult women. It is fundamental that this musculature supports a good function, because of the weakness of the pelvic floor produces urinary incontinence, cysto and rectocele, genital prolapses and sexual dysfunctions. The above mentioned pathology can be corrected by laparoscopic promontofixation, whatever the previous history of pelvic surgery, including the placing of prosthetic material. In this article we describe the above mentioned intervention. Preoperative care is standardized and is accompanied by antibiotic prophylaxis, preventive antithrombotic treatment and in the event of a history of pelvic surgery, a digestive preparation. Positioning of the patient must plan a 30° Trendelenbourg position. After the introduction the trocars, initial surgery comprises anterior dissection of promontory after incision of the posterior peritoneum with the patient placed beforehand in a Trendelembourg position. After that, we make interrectovaginal dissection to free the whole posterior surface of the vagina. This is followed by the installation of a posterior mesh pre-cut in an arc. After intervesical vaginal dissection, the anterior prosthesis comprising a precut polyester mesh is fixed avoiding excess traction. The end of the surgery involves careful reperitonization of all the prosthetic parts. Possible specific surgical complications are vascular and visceral wounds. RESULTS Y CONCLUSIONS: The technique allows the correction of the dysfunction of the pelvic floor and incontinence with good anatomical and functional results. Postoperative secondary haemorrhage and gastrointestinal occlusion may occur. Occurrence of an inflammatory syndrome and low back pain suggests spondylodicitis and MRI should be performed. Vaginal erosion on the prosthesis may occur after several months and seems

  7. Laparoscopic Toupet Fundoplication using an Air Seal Intelligent Flow System and Anchor Port in a 1.8-kg infant: A Technical Report.

    PubMed

    Miyano, Go; Morita, Keiichi; Kaneshiro, Masakatsu; Miyake, Hiromu; Nouso, Hiroshi; Yamoto, Masaya; Koyama, Mariko; Nakano, Reiji; Tanaka, Yasuhiko; Fukumoto, Koji; Urushihara, Naoto

    2015-08-01

    We report a case of a 1.8-kg infant who had laparoscopic Toupet fundoplication (LTF) using the AirSeal Intelligent Flow System and Anchor Port (AP). Our case had severe gastroesophageal reflux in association with genetic and cardiac anomalies. Despite the patient being continuously fed, persistent vomiting caused failure to thrive, and LTF was performed at 4 months of age when he weighed 1.8 kg. The AirSeal Intelligent Flow System is a novel laparoscopic CO2 insufflation system that improves the visual field by constantly evacuating smoke and providing a more stable pneumoperitoneum. The AP is a recently developed, stretchable, elastomeric, low-profile cannula. Three 5-mm AP were inserted: one subumbilically for the scope and one in both the right and left upper abdomen for the surgeon. A 5-mm AirSeal trocar was inserted in the left lower abdomen for the assistant. The gastrosplenic ligament was dissected free, and the intra-abdominal esophagus was prepared. A posterior hiatoplasty was performed, followed by the 270° fundoplication. During the fundoplication, the esophagus was fixed to the crus and then the right and left wraps were fixed to the esophagus. Pneumoperitoneum was maintained stably throughout the LTF procedure, with optimal operative field. Total operating time for LTF was 90 min. Body temperature dropped from 37.4°C to 35.7°C during pneumoperitoneum but resolved once pneumoperitoneum was ceased. Postoperative progress was uneventful, and an upper gastrointestinal study on postoperative day 2 showed no residual gastroesophageal reflux. We believe the AirSeal Intelligent Flow System and AP contributed to the successful completion of LTF in a 1.8-kg infant. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  8. Cadaver study of anatomic landmark identification for placing ankle arthroscopy portals.

    PubMed

    Scheibling, B; Koch, G; Clavert, P

    2017-05-01

    Arthroscopy-assisted surgery is now widely used at the ankle for osteochondral lesions of the talus, anterior and posterior impingement syndromes, talocrural or subtalar fusion, foreign body removal, and ankle instability. Injuries to the vessels and nerves may occur during these procedures. To determine whether ultrasound topographic identification of vulnerable structures decreased the risk of iatrogenic injuries to vessels, nerves, and tendons and influenced the distance separating vulnerable structures from the arthroscope introduced through four different portals. Ultrasonography to identify vulnerable structures before or during arthroscopic surgery on the ankle may be useful. Twenty fresh cadaver ankles from body donations to the anatomy institute in Strasbourg, France, were divided into two equal groups. Preoperative ultrasonography to mark the trajectories of vessels, nerves, and tendons was performed in one group but not in the other. The portals were created using a 4-mm trocar. Each portal was then dissected. The primary evaluation criterion was the presence or absence of injuries to vessels, nerves, and tendons. The secondary evaluation criterion was the distance between these structures and the arthroscope. No tendon injuries occurred with ultrasonography. Without ultrasonography, there were two full-thickness tendon lesions, one to the extensor hallucis longus and the other to the Achilles tendon. Furthermore, with the anterolateral, anteromedial, and posteromedial portals, the distance separating the vessels and nerves from the arthroscope was greater with than without ultrasonography (P=0.041, P=0.005, and P=0.002), respectively; no significant difference was found with the anterior portal. Preoperative ultrasound topographic identification decreases the risk of iatrogenic injury to the vessels, nerves, and tendons during ankle arthroscopy and places these structures at a safer distance from the arthroscope. Our hypothesis was confirmed. IV

  9. Robot-assisted laparoscopic transperitoneal infrarenal lymphadenectomy in patients with locally advanced cervical cancer by single docking: Do we need a backup procedure?

    PubMed

    Gucer, Fatih; Misirlioglu, Selim; Ceydeli, Nuri; Taskiran, Cagatay

    2018-03-01

    nine patients with LACC, the median docking time was 6.5 min (range 4-15 min), and the median operating time for para-aortic lymphadenectomy was 120 min (range 60-165 min). The median trocar time was 14.5 min (range 5-45 min). In two out of ten patients, the surgical removal of whole lymphatic tissue between inferior mesenteric artery and left renal vein was not completely possible by a single docking of robotic column. Therefore, a new optic trocar was placed in the umbilicus and the robotic column was relocated over the left shoulder of the patient and residual lymphatic tissue measuring approximately 2 cm in the long axis immediately below the left renal vein was removed and the surgery was completed up to the left renal vein. All para-aortic lymphadenectomies have been completed by robotic route. There were no intra-operative complications. No patient received a blood transfusion. Early post-operative grade 2 and 3a complications according to Dindo classification occurred in two patients: one symptomatic lymphocyst and one local infection on assistant port site in one patient. The patient with suspected para-aortic lymph node metastasis in PET/CT showed no metastatic disease on histopathologic exam of para-aortic lymph nodes. The patient with recurrent disease and negative para-aortic lymph nodes on frozen section examination underwent robot-assisted total pelvic exenteration. Five of the residual eight patients had histologically proven metastasis in the para-aortic lymph node(s). Treatment modification occurred in six patients related to pre-treatment staging surgery. According to pathological results, extended field radiation therapy has been added in five patients and it was omitted in one patient. The median time interval between surgery and initiation of radiotherapy was 12 days (range 6-23 days). Robotic transperitoneal infrarenal para-aortic lymphadenectomy up to left renal vein by high port insertion technique is a safe and feasible option for

  10. Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hakime, Antoine, E-mail: thakime@yahoo.com; Deschamps, Frederic; Marques De Carvalho, Enio Garcia

    2012-08-15

    Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid onmore » the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to

  11. First experience with single incision laparoscopic surgery in Slovakia: concomitant cholecystectomy and splenectomy in an 11-year-old girl with hereditary spherocytosis.

    PubMed

    Cingel, Vladimir; Zabojnikova, Lenka; Kurucova, Patricia; Varga, Ivan

    2014-09-01

    Hereditary spherocytosis is an autosomal dominant inheritance disorder of the red blood cell membrane characterized by the presence of spherical-shaped erythrocytes (spherocytes) in the peripheral blood. The main clinical features include haemolytic anemia, variable jaundice, splenomegaly and cholelithiasis caused by hyperbilirubinemia from erythrocyte hemolysis. Splenectomy does not solve the congenital genetic defect but it stops pathological hemolysis in the enlarged spleen. If gallstones are present, it is appropriate to perform cholecystectomy at the time of splenectomy, although the patient has symptoms of gall bladder disease. We present the case of single incision laparoscopic surgical (SILS) concomitant splenectomy and cholecystectomy performed with conventional laparoscopic instruments in an 11-year-old girl with the diagnosis of hereditary spherocytosis. A 2-3 cm umbilical incision was used for the placement of two 5 mm trocars and one 10 mm flexible videoscope. Conventional laparoscopic dissector, grasper, Ligasure, Harmonic Ace and hemoclips were the main tools during surgical procedure. We prefer Single Incision Laparoscopic Surgery Foam Port (Covidien) as the single umbilical device for introduction into the abdominal cavity. First, we performed cholecystectomy, then the gallbladder was put aside over the liver and after that we peformed splenectomy. To remove the detached spleen and gallbladder, a nylon extraction bag is introduced through one of the port sites. The spleen is than morcellated in the bag with forceps and removed in fragments. After that we removed them and the umbilical fascial incision was closed. Splenectomy is the only effective therapy for this disorder and often it is performed in combination with cholecystectomy. Conventional surgery requires a wide upper abdominal incision for correct exposure of the gallbladder and spleen. Our experience shows that SILS splenectomy and cholecystectomy is feasible even in young children and

  12. Cholecystectomy using a novel Single-Site(®) robotic platform: early experience from 45 consecutive cases.

    PubMed

    Konstantinidis, Konstantinos M; Hirides, Petros; Hirides, Savas; Chrysocheris, Pericles; Georgiou, Michael

    2012-09-01

    The aim of this work was to study the feasibility, safety, and efficacy of single-incision robotic cholecystectomy using a novel platform from Intuitive Surgical. All operations were performed by the same surgeon. Parameters assessed included patient history, indication for surgery, operation time, complication rate, conversion rate, robot-related issues, length of hospital stay, postoperative pain, and time to return to work. All patients were followed for a 2-month period postoperatively. Forty-five patients (22 women, 23 men) underwent single-incision robotic cholecystectomy from March 1 to July 15, 2011. There were no conversions to either conventional laparoscopy or laparotomy, although in three cases a second trocar was used. There were no major complications apart from a single case of postoperative hemorrhage. Average patient age was 47 ± 12 years (range = 27-80 years) and average BMI was 30 kg/m(2) (mean = 28.8 ± 4 kg/m(2), range = 18.4-46.7 kg/m(2)). The primary indication for surgery was gallstones. The mean operation time (skin-to-skin) was 84.5 ± 25.5 min (range = 51-175 min), docking time was 5.8 ± 1.5 min (range = 4-11 min), and console time (net surgical time) was 43 ± 21.9 min (range = 21-121 min). Intraoperative blood loss was negligible. There were no collisions between the robotic arms and no other robot-related problems. Average postoperative length of stay was less than 24 h. The mean Visual Analog Pain Scale Score 6 h after the operation was 2.2 ± 1.51 (range = 0-6) and patients returned to normal activities in 4.48 ± 2.3 days (range = 1-9 days). Single-Site(®) is a new platform offering a potentially more stable and reliable environment to perform single-port cholecystectomy. Both simple and complicated cholecystectomies can be performed with safety. The technique is possible in patients with a high BMI. The induction of pneumoperitoneum using the new port and the docking process require additional training.

  13. Feasibility of robotic inguinal hernia repair, a single-institution experience.

    PubMed

    Escobar Dominguez, Jose E; Ramos, Michael Gonzalez; Seetharamaiah, Rupa; Donkor, Charan; Rabaza, Jorge; Gonzalez, Anthony

    2016-09-01

    With the growth of the discipline of laparoscopic surgery, technology has been further developed to facilitate the performance of minimally invasive hernia repair. Most of the published literature regarding robotic inguinal hernia repair has been performed by urologists who have dealt with this entity in a concomitant way during radical prostatectomies. General surgeons, who perform the vast majority of inguinal herniorrhaphies worldwide, have yet to describe the role of robotic inguinal hernia repair. Here, we describe our initial experience and create the foundation for future research questions regarding robotic inguinal hernia repair. A retrospective chart review was performed in 78 patients who underwent robotic transabdominal preperitoneal TAPP inguinal hernia repair with a prosthetic mesh using the da Vinci platform (Intuitive Surgical Inc). Data collected included patient demographics, past medical history, previous surgeries, details related to the surgical procedure, perioperative outcomes and complications. A total of 123 hernias were repaired. Forty-five patients had bilateral robotic inguinal herniorrhaphies, and the mean age was 55.1 years (SD 15.1), with a mean BMI of 27.6 (SD 6.1). There were 71 male and 7 female patients. Surgical complications included hematoma in three patients (3.9 %), two seromas (2.6 %) and one superficial surgical site infection at a trocar site (1.3 %), which resolved with oral antibiotics. Chronic postoperative complications (>30 days post-surgery) included the persistence of hematomas in two patients (2.6 %). Same day discharge was achieved in 60 patients (76.9 %) with a mean length of stay of 8 h (SD 2.65). Neither mortality nor conversion to open surgery occurred. Our early experience has demonstrated that the robotic transabdominal preperitoneal (TAPP) inguinal hernia repair is a safe and versatile approach that allows the general surgeon to perform this procedure in more complex cases such as those involving

  14. Twenty-year experience with laparoscopic inguinal hernia repair in infants and children: considerations and results on 1833 hernia repairs.

    PubMed

    Esposito, Ciro; Escolino, Maria; Cortese, Giuseppe; Aprea, Gianfranco; Turrà, Francesco; Farina, Alessandra; Roberti, Agnese; Cerulo, Mariapina; Settimi, Alessandro

    2017-03-01

    The role of laparoscopy in pediatric inguinal hernia (IH) is still controversial. The authors reported their twenty-year experience in laparoscopic IH repair in children. In a twenty-year period (1995-2015), we operated 1300 infants and children (935 boys-365 girls) with IH using laparoscopy. The average age at surgery was 18 months (range 7 days-14 years). Body weight ranged between 1.9 and 50 kg (average 9.3). Preoperatively all patients presented a monolateral IH, right-sided in 781 cases (60.1 %) and left-sided in 519 (39.9 %). We excluded patients with bilateral IH and unstable patients in which laparoscopy was contraindicated. If the inguinal orifice diameter was ≥10 mm, we performed a modified purse string suture on peri-orificial peritoneum, in orifices ≤5 mm, we performed a N-shaped suture. No conversion to open surgery was reported. In 533 cases (41 %), we found a contralateral patency of internal inguinal ring that was always closed in laparoscopy. In 1273 cases (97.9 %), we found an oblique external hernia; in 21 cases (1.6 %), a direct hernia; and in 6 cases (0.5 %), a double hernia on the same side (hernia en pantaloon). We found an incarcerated hernia in 27 patients (2 %). Average operative time was 18 min (range 7-65). We recorded 5/1300 recurrences (0.3 %), but in the last 950 patients, we had no recurrence (0 %). We recorded 20 complications (1.5 %): 18 umbilical granulomas and two trocars scar infections, treated in outpatient setting. On the basis of our twenty-year experience, we prefer to perform IH repair in children using laparoscopy rather than inguinal approach. Laparoscopy is as fast as inguinal approach, and it has the advantage to treat during the same anesthesia a contralateral patency occured in about 40 % of our cases and to treat also rare hernias in about 3 % of cases.

  15. The Laparosound{trade mark, serif}-an ultrasonic morcellator for use in laparoscopic surgery

    NASA Astrophysics Data System (ADS)

    Malinowski, Igor; Łobodzinski, Suave S.; Paśniczek, Roman

    2012-05-01

    The laparoscopic surgery has gained presence in the operating room in cases where it is feasible to spare patient trauma and minimize the hospital stay. One unique challenge in laparoscopic/endoscopic surgery is operating and removing tissue volume through keyhole - trocar. The removal of tissues by fragmentation is generally termed morcellation. We proposed a new method for soft tissue morcellation using laparoscopy. A unique ultrasonic laparoscopic surgical device, termed Laparosound{trade mark, serif}, utilizing laparoscopic high amplitude ultrasonic waveguides, operating in edge mode, has been developed that uses the principle of ultrasonic cavitation phenomenon for excision and morcellation of a variety of tissue types. The local ultrasonic acoustic intensity at the distal waveguide tip is sufficiently high that the liquefaction of moist tissue occurs. The mechanism of tissue morcellation is deemed to be cavitation based, therefore is dependant on water content in tissue, and thus its effectiveness depends on tissue type. This results in ultrasound being efficient in moist tissue and sparing dry, collagen rich blood vessels and thus minimizes bleeding. The applications of such device in particular, commonly encountered, could lay in general and ob/gyn laparoscopic surgery, whereas other applications could emerge. The design of power ultrasonic instruments for mass clinical applications poses however unique challenges, such as ability to design and build ultrasonic resonators that last in conditions of ultrasonic fatigue. These highly non-linear devices, whose behavior is hard to predict, have become the challenge of the author of the present paper. The object of work is to design and build an operating device capable of ultrasonic soft tissue morcellation in laparoscopic surgery. This includes heavy computational ultrasonics verified by testing and manufacturing feasibility using titanium biomedical alloys. The prototype Laparosound{trade mark, serif} device

  16. [Malpractice in laparoscopic cholecystectomy. Results of cases recently considered by the Expert Commission].

    PubMed

    Kienzle, H F

    1999-01-01

    The Expert Commission for medical malpractice which is part of the Medical Chamber of Nordrhein received about 60 applications in connection with laparoscopic cholecystectomy; as of August 1998 5 complaints were let off and 11 of them are still being considered. So far 44 complaints have been considered and in 25 of them medical malpractice has been established. The medical malpractice detected laparoscopic cholecystectomy cases were mainly bile duct injuries of which 13 required a biliodigestive anastomosis for reconstruction, four cases required and end-to-end anastomosis and in one case a T-tube drainage was needed. The youngest one of these patients was 21 years old, the oldest one was 61 years old. Four times the bile duct injury was not considered as malpractice, because it could be intraoperatively made out and immediately treated. Trocar injuries were twice a cause for malpractice and once it was not. Each of the following cases was also recognized as a malpractice. One lost gallstone one dislocated Roedersnare, one electric injury, one delayed reintervention and one insufficient information. The following cases were decided as non-malpractice: in two cases a slipped clip, in five cases subhepatical hematoma/abscess, in three cases a secondary bleeding, once a lesion of the splenic capsule and finally a running sore with subsequent incisional hernia. Three courses of treatment with consequence of death also contained mistakes: one electric injury of the bowel, one bile duct lesion and one information rebuke. The bile duct injury is the most considerable risk for laparoscopic cholecystectomy and implies also a high risk for the future health. The experienced surgeon distinguishes himself by the fact that he is right about the situation and converts sooner that later to conventional cholecystectomy if there's any doubt. In open surgery the principle is applied that structures may be only divided when they are clearly identified. The same goes even on a wider

  17. Laparoscopic sleeve gastrectomy achieves substantial weight loss in an adolescent girl with morbid obesity.

    PubMed

    Till, H K-H; Muensterer, O; Keller, A; Körner, A; Blueher, S; Merkle, R; Kiess, W

    2008-02-01

    The European guidelines for bariatric surgery clearly define criteria for operating children with morbid obesity. However the appropriate technique for this age-group has not been identified yet. So far gastric banding and Roux-Y bypass represent the standards, but they demand life-long tolerance of either an artificial device or significant malabsorption. Although laparoscopic sleeve gastrectomy (LSG) demands neither, it has not been advocated for this age-group as a stand-alone technique. We report the outcome and the rationale for this approach in a 16-year-old girl with morbid obesity. The patient had been in an intensive weight loss programme for several years, but within the last 12 months her body weight had increased again dramatically. At referral she presented with a body mass index (BMI) of 43.1 kg/m(2) (height 169 cm, preoperative weight 121 kg) and suffered from co-morbidities as features of a developing metabolic-vascular syndrome such as dyslipidemia and arterial hypertension. Our obesity team and her parents opted for surgery at that time. The patient underwent LSG with a 5-trocar technique. With a gastroscope protecting the lesser curvature, the stomach was resected from the antrum to the fundus using an EndoGIA stapler. The operative time was 95 minutes, there were no perioperative complications and the patient was extubated immediately. An upper GI contrast study on postoperative day 4 showed a tubular gastric remnant with a volume of about 200 ml. The patient's diet was advanced as tolerated to full oral intake, and she was followed-up regularly in our special obesity outpatient clinic. After 12 months she had lost 36 kg (BMI 29 kg/m(2)) and enjoyed sports and activities with friends again. Laboratory studies ruled out malnutrition or vitamin deficiency. LSG is a safe and effective option for bariatric surgery in obese adolescents. It can be offered as a stand-alone restrictive operation and could be extended to a malabsorptive procedure at any

  18. Single-incision retroperitoneoscopic adrenalectomy: a North American experience.

    PubMed

    Sho, Shonan; Yeh, Michael W; Li, Ning; Livhits, Masha J

    2017-07-01

    Endoscopic adrenalectomy is currently performed using multiple ports placed either transabdominally or retroperitoneally. We report our initial experience with single-incision retroperitoneoscopic adrenalectomy (SIRA). A prospective database of patients undergoing adrenalectomy from December 2013 through March 2016 was analyzed. We adopted conventional retroperitoneoscopic adrenalectomy (CORA) in December 2013 and transitioned to SIRA in March 2015. SIRA was performed using three trocars placed through a single 2-cm incision below the 12th rib. Clinical characteristics and outcomes were compared between patients undergoing SIRA and CORA. One hundred and five adrenalectomies were performed in 102 patients: 34 laparoscopic transperitoneal, 24 CORA, 37 SIRA and 7 open. The SIRA and CORA groups were similar with respect to clinical characteristics (SIRA vs. CORA: mean BMI 27.0 vs. 28.8 kg/m 2 , maximum BMI 38.9 vs. 44.3 kg/m 2 ; mean nodule size 3.2 vs. 3.2 cm, maximum nodule size 8.0 vs. 6.0 cm). One patient undergoing SIRA required placement of an additional 5-mm port because of extensive adhesions. No patients who underwent SIRA or CORA required conversion to open adrenalectomy. There were no deaths, and blood loss remained <10 mL for all cases. Operative length was similar between SIRA and CORA (105 vs. 92 min, P = 0.26). In multivariable linear regression analysis, nodule size > 5 cm (effect = 1.75, P < 0.001) and pheochromocytoma (effect = 1.30, P = 0.05) were significant predictors of increased operative length for SIRA. BMI and laterality (right vs. left) did not affect operative length. Rates of postoperative temporary abdominal wall relaxation, length of stay and postoperative pain medication use were similar between the two groups. SIRA is safe and feasible to implement as a refinement of CORA and may be applied to technically challenging cases involving obese patients or large nodules. The use of three ports allows for two

  19. Robotic-assisted laparoscopic radical nephrectomy using the Da Vinci Si system: how to improve surgeon autonomy. Our step-by-step technique.

    PubMed

    Davila, Hugo H; Storey, Raul E; Rose, Marc C

    2016-09-01

    Herein, we describe several steps to improve surgeon autonomy during a Left Robotic-Assisted Laparoscopic Radical Nephrectomy (RALRN), using the Da Vinci Si system. Our kidney cancer program is based on 2 community hospitals. We use the Da Vinci Si system. Access is obtained with the following trocars: Two 8 mm robotic, one 8 mm robotic, bariatric length (arm 3), 15 mm for the assistant and 12 mm for the camera. We use curved monopolar scissors in robotic arm 1, Bipolar Maryland in arm 2, Prograsp Forceps in arm 3, and we alternate throughout the surgery with EndoWrist clip appliers and the vessel sealer. Here, we described three steps and the use of 3 robotic instruments to improve surgeon autonomy. Step 1: the lower pole of the kidney was dissected and this was retracted upwards and laterally. This maneuver was performed using the 3rd robotic arm with the Prograsp Forceps. Step 2: the monopolar scissors was replaced (robotic arm 1) with the robotic EndoWrist clip applier, 10 mm Hem-o-Lok. The renal artery and vein were controlled and transected by the main surgeon. Step 3: the superior, posterolateral dissection and all bleeders were carefully coagulated by the surgeon with the EndoWrist one vessel sealer. We have now performed 15 RALRN following these steps. Our results were: blood loss 300 cc, console time 140 min, operating room time 200 min, anesthesia time 180 min, hospital stay 2.5 days, 1 incisional hernia, pathology: (13) RCC clear cell, (1) chromophobe and (1) papillary type 1. Tumor Stage: (5) T1b, (8) T2a, (2) T2b. We provide a concise, step-by-step technique for radical nephrectomy (RN) using the Da Vinci Si robotic system that may provide more autonomy to the surgeon, while maintaining surgical outcome equivalent to standard laparoscopic RN.

  20. Laparoscopic ovariectomy using sequential electrocoagulation and sharp transection of the equine mesovarium.

    PubMed

    Rodgerson, D H; Belknap, J K; Wilson, D A

    2001-01-01

    To describe in horses and ponies a laparoscopic ovariectomy technique facilitated by electrosurgical instrumentation. Elective ovariectomy was performed in 23 mares using laparoscopic electrosurgical instrumentation. Twenty-three mares (13 horses, 10 ponies), aged from 2 to 21 years and weighing 90 to 545 kg. Food was withheld for a minimum of 12 hours. Mares were sedated with detomidine hydrochloride (0.02 to 0.03 mg/kg) or xylazine hydrochloride (0.5 to 1.0 mg/kg). Excluding the pony mares, all other mares were restrained in stocks. Portal sites in the paralumbar fossa region were desensitized with 2% mepivacaine. Abdominal insufflation was achieved through a teat cannula positioned in the ventral abdomen or a Verres-type needle placed through the paralumbar fossa. After trocar and laparoscope insertion, the ipsilateral ovary and mesovarium were identified, and the mesovarium, tubal membrane, and proper ligament were infiltrated with 2% mepivacaine. The mesovarium was coagulated using bipolar or monopolar electrosurgical forceps and transected sequentially from cranial to caudal until the ovary was completely freed and then removed. The contralateral ovary was removed in a similar fashion through the opposite paralumbar fossa. Bipolar and monopolar electrosurgical forceps were easy to use and provided adequate coagulation of vessels within the mesovarium. Two mares were euthanatized after the procedure for unrelated reasons. One mare had mild signs of colic 24 hours after ovariectomy. In 1 pony mare, the incision used to remove one ovary dehisced on the 5th postoperative day and was allowed to heal by second-intention. No long-term complications had occurred in 11 horses and 10 ponies, 6 to 24 months after surgery. Laparoscopic ovariectomy and hemostasis of the mesovarium can be easily accomplished using electrosurgical instrumentation. Standing laparoscopic ovariectomy, using electrosurgical instrumentation, is an effective and safe technique to provide

  1. Robot-assisted single-site compared with laparoscopic single-incision cholecystectomy for benign gallbladder disease: protocol for a randomized controlled trial.

    PubMed

    Grochola, Lukasz Filip; Soll, Christopher; Zehnder, Adrian; Wyss, Roland; Herzog, Pascal; Breitenstein, Stefan

    2017-02-09

    Recent advances in robotic technology suggest that the utilization of the da Vinci Single-Site™ platform for cholecystectomy is safe, feasible and results in a shorter learning curve compared to conventional single-incision laparoscopic cholecystectomy. Moreover, the robot-assisted technology has been shown to reduce the surgeon's stress load compared to standard single-incision laparoscopy in an experimental setup, suggesting an important advantage of the da Vinci platform. However, the above-mentioned observations are based solely on case series, case reports and experimental data, as high-quality clinical trials to demonstrate the benefits of the da Vinci Single-Site™ cholecystectomy have not been performed to date. This study addresses the question whether robot-assisted Single-Site™ cholecystectomy provides significant benefits over single-incision laparoscopic cholecystectomy in terms of surgeon's stress load, while matching the standards of the conventional single-incision approach with regard to peri- and postoperative outcomes. It is designed as a single centre, single-blinded randomized controlled trial, which compares both surgical approaches with the primary endpoint surgeon's physical and mental stress load at the time of surgery. In addition, the study aims to assess secondary endpoints such as operating time, conversion rates, additional trocar placement, intra-operative blood loss, length of hospital stay, costs of procedure, health-related quality of life, cosmesis and complications. Patients as well as ward staff are blinded until the 1 st postoperative year. Sample size calculation based on the results of a previously published experimental setup utilizing an estimated effect size of surgeon's comfort of 0.8 (power of 0.8, alpha-error level of 0.05, error margin of 10-15%) resulted in a number of 30 randomized patients per arm. The study is the first randomized controlled trial that compares the da Vinci Single Site™ platform to

  2. The Effect of Product Safety Courses on the Adoption and Outcomes of LESS Surgery

    PubMed Central

    Toomey, Paul G.; Ross, Sharona B.; Choung, Edward; Donn, Natalie; Vice, Michelle; Luberice, Kenneth; Albrink, Michael

    2015-01-01

    Background and Objectives: As technology in surgery evolves, the medical instrument industry is inevitability involved in promoting the use and appropriate (ie, effective and safe) application of its products. This study was undertaken to evaluate industry-supported product safety courses in laparoendoscopic single-site (LESS) surgery, by using the metrics of surgeons' adoption of the technique, safety of the procedure, and surgeons' perception of the surgery. Methods: LESS surgery courses that involved didactic lectures, operative videos, operation observation, collaborative learning, and simulation, were attended by 226 surgeons. With Florida Hospital Tampa Institutional Review Board approval, the surgeons were queried before and immediately after the course, to assess their attitudes toward LESS surgery. Then, well after the course, the surgeons were contacted, repeatedly if necessary, to complete questionnaires. Results: Before the course, 82% of the surgeons undertook more than 10 laparoscopic operations per month. Immediately after the course, 86% were confident that they were prepared to perform LESS surgery. Months after the course, 77% of the respondents had adopted LESS surgery, primarily cholecystectomy; 59% had added 1 or more trocars in 0–20% of their procedures; and 73% held the opinion that operating room observation was the most helpful learning experience. Complications with LESS surgery were noted 12% of the time. Advantages of the technique were better cosmesis (58%) and patient satisfaction (38%). Disadvantages included risk of complications (37%) and higher technical demand (25%). Seventy-eight percent viewed LESS surgery as an advancement in surgical technique. Conclusion: In multifaceted product safety courses, operating room observation is thought to provide the most helpful instruction for those wanting to undertake LESS surgery. The procedure has been safely adopted by surgeons who frequently perform laparoscopies. The tradeoff is in

  3. The best option: Umbilical LESS radical nephrectomy with vaginal extraction.

    PubMed

    Andrés, G; García-Mediero, J M; García-Tello, A; Arance, I; Cabrera, P M; Angulo, J C

    2015-04-01

    Umbilical laparoendoscopic single-site (LESS) surgery represents an excellent alternative to laparoscopic or robotic multiport surgery. LESS surgery offers faster recovery, less postoperative pain and optimal cosmetic results. The reusable nature of its instruments also has significant economic advantages. We present a 34-year-old patient with a solid mesorenal lesion measuring 8 cm in the left kidney treated with pure LESS radical nephrectomy assisted by vaginal extraction of the specimen. The umbilical approach using a single-site multichannel KeyPort (Richard Wolf GmbH, Knittlingen, Germany) with DuoRotate curved instruments allows for minimum crushing and fewer spatial conflicts. Its perfect umbilical adaptation provides a hermetic system. The instrument's double rotation provides considerable movement precision. Vaginal extraction avoids damage to the abdominal wall and the need for widening the umbilical incision. After the placement of the device and triangulation of the clips, we proceeded to operate on posterior parietal peritoneum. The descending colon was mobilized to access the retroperitoneum and dissect the renal hilum. Hem-o-lok clips were placed on the artery and vein, which were subsequently sectioned. The specimen was inserted into a laparoscopic bag. Under direct vision, we placed a 15-mm trocar through the bottom of the vaginal posterior fornix to facilitate the extraction of the bag's thread. The incision was widened with the fingers, and the specimen was extracted, closing the vagina from the perineum with visualization from the navel. Abdominal drainage was not employed. The surgical time was 180 min. The patient was discharged the following day without needing analgesia. A year later, the patient was disease-free and had no complications. Umbilical LESS radical nephrectomy with vaginal extraction is feasible in selected cases. The procedure is oncologically safe, avoids scars and facilitates early recovery. From a practical point of view

  4. Retroperitoneal and transperitoneal robot-assisted pyeloplasty in adults: techniques and results.

    PubMed

    Cestari, Andrea; Buffi, Nicolò Maria; Lista, Giuliana; Sangalli, Mattia; Scapaticci, Emanuele; Fabbri, Fabio; Lazzeri, Massimo; Rigatti, Patrizio; Guazzoni, Giorgio

    2010-11-01

    The surgical management of ureteropelvic junction obstruction (UPJO) has dramatically evolved over the past 20 yr due to the development of new technology. Our aim was to report the feasibility and efficacy of robot-assisted pyeloplasty (RAP) performed by either the retroperitoneal or the transperitoneal approach. A stage 2 investigative study was conducted including development (stage 2a) and exploration (stage 2b) of transperitoneal and retroperitoneal RAP performed in 55 patients at an urban tertiary university department of urology. Retroperitoneal RAP was performed with the patient in full flank position using a 12-mm Hasson-style optical port at the tip of the 12th rib, plus two operative 8-mm robotic trocars and an assistant 5-mm port. The stenotic ureteropelvic junction was excised, the ureter was spatulated, and a dismembered pyeloplasty was performed in all cases. Transperitoneal RAP was performed with the patients in the 60° flank position. The optical port is in the umbilical area, plus two 8-mm operative robotic ports and one 5-mm assistant port. The pyeloplasty technique is similar to the retroperitoneoscopic approach. In both groups, the stent can be positioned in an anterograde or retrograde fashion. Success consisted of no evidence of obstruction on computed tomography urography or mercaptoacetyltriglycine-3 diuretic renal scan, no postoperative symptoms, and no further treatment. Thirty-six patients underwent retroperitoneoscopic RAP and 19 transperitoneal RAP for UPJO. All the procedures were completed with robotic assistance. The overall objective success (measured by diuretic renal scan and/or imaging techniques) was 96% with two cases of recurrence (both in the retroperitoneal group). The main limitation was the short follow-up, although all patients reached at least a 6-mo follow-up. RAP performed either retroperitoneally or transperitoneally was revealed as a feasible and reproducible surgical option for the treatment of UPJO, offering a

  5. Injectable self inflating hydrogel pellet expanders for the treatment of orbital volume deficiency in congenital microphthalmos: preliminary results with a new therapeutic approach

    PubMed Central

    Schittkowski, M P; Guthoff, R F

    2006-01-01

    Background/aim Children with congenital microphthalmos are usually able to wear an eye prosthesis but the cosmetic aspect is determined by the size of the orbital volume deficiency. Instead of using a ball shaped standard hydrogel expander or a regular orbital implant, which would necessitate enucleation of the microphthalmic eye, this study investigates the feasibility of volume augmentation with injectable pellet expanders, as formerly suggested for acquired anophthalmos in adults only. Method The pellet expander is made from a self inflating hydrogel that takes up water by osmosis (dry state: length 8 mm, diameter 2 mm, volume 0.025 ml; in vitro hydrated state after around 1 day: length 15 mm, diameter 4 mm, volume 0.24 ml; swelling capacity: 9.6‐fold). This report concerns six patients (two girls and four boys) aged between 4 months and 42 months with unilateral microphthalmos who were treated by injection of 4–14 pellet expanders into the retrobulbar orbital tissue. Volume augmentation was 1–3.5 ml. The pellets were injected using a customised trocar and placed behind the microphthalmos directed into the intraconal space. Results The increasing orbital volume was noticeable within 2 days and was confirmed by ultrasonography and magnetic resonance imaging. The final result can be anticipated by the volume augmentation effect produced by the amount of saline solution injected in the orbital apex region. All patients were fitted with an artificial eye, which was subsequently enlarged every 3–5 months. Anophthalmic enophthalmos was fully compensated with this technique. No complications have been encountered to date. Conclusions Orbital volume augmentation with injectable self inflating hydrogel expander pellets is apparently a safe, quick, and minimally invasive technique for various indications in orbital reconstructive surgery—for example, to treat an enophthalmic appearance in microphthalmos and congenital or acquired

  6. [Laser-induced thermotherapy (LITT) of lung metastases: description of a miniaturized applicator, optimization, and initial treatment of patients].

    PubMed

    Hosten, N; Stier, A; Weigel, C; Kirsch, M; Puls, R; Nerger, U; Jahn, D; Stroszczynski, C; Heidecke, C-D; Speck, U

    2003-03-01

    A thin-caliber applicator system was developed for introducing a laser fiber under CT guidance into lung metastases with only minimal complications. A space-saving 5.5 French Teflon cannula with a titanium trocar and connectors for a laser light guide (2 or 3 cm Dornier Diffusor-Tip H-6111-T2 or H-6111-T3 coupled to a Dornier Medilas Fibertom 5100 laser, wavelength of 1064 nm) and a perfusion line for physiologic saline solution were developed. After puncture the laser Diffusor-Tip remains in the cannula and is cooled during its tissue passage by slowly flowing saline solution. The miniaturized applicator system (Monocath) was calibrated in nonperfused bovine liver for maximum energy supply and necessary flow of the cooling saline solution in reference to a commercially available 9 French laser catheter with an 11.5 French inducer sheath (Power-Applicator). The new applicator system was used for treating lung metastases in 10 patients over a period of 21 months. The size of heat coagulation in bovine liver was 24 +/- 2 ml using the miniaturized system with application of 15 W for 20 min and a saline flow of 0.75 ml/min, in comparison to a size of 29 +/- 7 ml for the commercial applicator (30 W, 20 min, 60 ml/min). All metastases could be safely approached with the miniaturized applicator, except for two metastatic lesions at the lung base in two patients. A minor pneumothorax developed in three patients and intrapulmonary bleeding in two. Contrast-enhanced CT demonstrated necrosis of the treated metastatic areas in 6 patients. Follow-up of three patients after 5, 6, and 8 months showed complete tumor regression with minimal scarring in one patient. The miniaturized applicator system enables the introduction of a laser fiber into pulmonary metastases with only minor complications. Complete ablation seems to be achievable in suitable patients with the applied laser energy and a slow cooling fluid flow rate.

  7. Single-site Laparoscopic Colorectal Surgery Provides Similar Clinical Outcomes Compared to Standard Laparoscopic Surgery: An Analysis of 626 Patients

    PubMed Central

    Sangster, William; Messaris, Evangelos; Berg, Arthur S.; Stewart, David B.

    2015-01-01

    BACKGROUND Compared to standard laparoscopy, single-site laparoscopic colorectal surgerymay potentially offer advantages by creating fewer surgical incisions and providing a multi-functional trocar. Previous comparisons, however, have been limited by small sample sizes and selection bias. OBJECTIVE To compare 60-day outcomes between standard laparoscopic and single-site laparoscopic colorectal surgery patients undergoing elective and urgent surgeries. DESIGN This was an unselected retrospective cohort study comparing patients who underwent elective and unplanned standard laparoscopic or single-site laparoscopic colorectal resections for benign and malignant disease between 2008 and 2014. Outcomes were compared using univariate analyses. SETTING This study was conducted at a single institution. PATIENTS A total of 626 consecutive patients undergoing laparoscopic colorectal surgery were included. MAIN OUTCOME MEASURES Morbidity and mortality within 60 postoperative days. RESULTS 318 (51%) and 308 (49%) patients underwent standard laparoscopic and single-site laparoscopic procedures, respectively. No significant difference was noted in mean operative time (Standard laparoscopy 182.1 ± 81.3 vs. Single-site laparoscopy 177±86.5, p=0.30) and postoperative length of stay (Standard laparoscopy 4.8±3.4 vs. Single-site laparoscopy 5.5 ± 6.9, p=0.14). Conversions to laparotomy and 60-day readmissions were also similar for both cohorts across all procedures performed. A significant difference was identified in the number of patients who developed postoperative complications (Standard laparoscopy 19.2% vs. Single-site laparoscopy 10.7%, p=0.004), especially with respect to surgical-site infections (Standard laparoscopy 11.3% vs. Single-site laparoscopy 5.8%, p=0.02). LIMITATIONS This was a retrospective, single institution study. CONCLUSIONS Single-site laparoscopic colorectal surgery demonstrates similar results to standard laparoscopic colorectal surgery in regards to

  8. Outcomes of laparoscopic adrenalectomy. Clinical experience with 68 patients.

    PubMed

    Pugliese, Raffaele; Boniardi, Marco; Sansonna, Fabio; Maggioni, Dario; De Carli, Stefano; Costanzi, Andrea; Scandroglio, Ildo; Ferrari, Giovanni Carlo; Di Lernia, Stefano; Magistro, Carmelo; Loli, Paola; Grossrubatscher, Erika

    2008-07-01

    The aim of this study was to analyze feasibility and outcomes of laparoscopic adrenalectomy (LA). Pathology, size and bilateral site of lesions were considered. Between December 1998 and May 2007 in our institution a total of 68 patients of mean age of 53 years underwent unilateral (n=57) or bilateral (n=11) LA. Adrenal masses averaged 5.4cm in size (range 1.2-13cm) and 56.7g in weight (range 10-265) including 71 benign and 8 malignant lesions. A total of 79 adrenal glands were resected, 44 right sided and 35 left sided. Removal was complete in 77 cases and partial (sparing adrenalectomy) in 1 patient affected by bilateral pheochomocytoma. Three left adrenalectomies for pheochromocytoma were robot-assisted. The transperitoneal lateral approach was preferred and the posterior retroperitoneal approach was adopted in 5 patients. The mean duration of surgery for each LA was 138+/-90min and 3.8 trocar were used on average (range 3-6). Conversion was needed in 3 cases owing to difficult dissection of large masses. Estimated mean blood loss for each LA was 95+/-30ml and it was greater for bilateral LA. Mortality was nil and morbidity was 5.8%. The average length of hospital stay (LOS) in surgical unit was 4+/-2.4 days (range 2-8). Patients affected by hormone secreting or bilateral lesions, by unilateral or bilateral pheochromocytoma and by bilateral Cushing's disease were transferred to the endocrinological ward so that their overall hospital stay was prolonged to 9+/-2.8 days on average (range 7-17). Mean duration of follow-up of patients was 38 months (range 2-100) and demonstrated acceptable endocrine results. Three primary cortical carcinomas were discovered as chance findings on histologic examination. While long-term results after LA for cortical carcinomas were poor and LA is not recommended in such cases, long-term results after LA for adrenal metastases were encouraging.

  9. Role of Robotics in Children: A brave New World!

    PubMed

    Spinoit, Anne-Françoise; Nguyen, Hiep; Subramaniam, Ramnath

    2017-04-01

    The key in the evolution towards minimally invasive surgery is the availability of appropriate equipment, especially when procedures involve children. While robotic procedures in adults continue to struggle to prove measurable advantages compared with open or classical laparoscopic ones, the use of the robotic platform (RP) in pediatric urology is steadily increasing. To review the contemporary literature regarding the use of robotic-assisted (RA) urologic interventions in children. A nonsystematic review of the literature was conducted through PubMed database between 2002 and 2017, with an emphasis on large series. A few major challenges must be considered before using the RP in children: anesthesia, placement of trocars, and technical difficulties related to small space. To date, only the robot-assisted pyeloplasty is recognized as safe and efficient with an equivalent outcome compared to the open or classical laparoscopy; this was supported by large multicentric studies, which are not available for most of the other procedures. RA procedure in children has been proven safe and effective. Still in its infancy, further data over time is likely to prove different RA procedures to be equivalent to open or laparoscopy in terms of outcome. The advent of the robotic platform means an evolution towards minimizing surgical trauma for the child. Currently, the available platforms designed for adults are adapted to work in children. However, it might be expected in the future that new technologies will improve the technical possibilities to improve the robotic platform for minimally invasive surgery in children. To date, a few applications are considered safe and efficient (in experienced hands), considering that the team has to be aware of some challenges to overcome regarding anesthesia, material, and technique adaptation to the patient. The most accepted robotic applications in children comprises of the robot-assisted pyeloplasty, hemi-nephrectomy, and ureteric

  10. Intraoperative magnetic tracker calibration using a magneto-optic hybrid tracker for 3-D ultrasound-based navigation in laparoscopic surgery.

    PubMed

    Nakamoto, Masahiko; Nakada, Kazuhisa; Sato, Yoshinobu; Konishi, Kozo; Hashizume, Makoto; Tamura, Shinichi

    2008-02-01

    This paper describes a ultrasound (3-D US) system that aims to achieve augmented reality (AR) visualization during laparoscopic surgery, especially for the liver. To acquire 3-D US data of the liver, the tip of a laparoscopic ultrasound probe is tracked inside the abdominal cavity using a magnetic tracker. The accuracy of magnetic trackers, however, is greatly affected by magnetic field distortion that results from the close proximity of metal objects and electronic equipment, which is usually unavoidable in the operating room. In this paper, we describe a calibration method for intraoperative magnetic distortion that can be applied to laparoscopic 3-D US data acquisition; we evaluate the accuracy and feasibility of the method by in vitro and in vivo experiments. Although calibration data can be acquired freehand using a magneto-optic hybrid tracker, there are two problems associated with this method--error caused by the time delay between measurements of the optical and magnetic trackers, and instability of the calibration accuracy that results from the uniformity and density of calibration data. A temporal calibration procedure is developed to estimate the time delay, which is then integrated into the calibration, and a distortion model is formulated by zeroth-degree to fourth-degree polynomial fitting to the calibration data. In the in vivo experiment using a pig, the positional error caused by magnetic distortion was reduced from 44.1 to 2.9 mm. The standard deviation of corrected target positions was less than 1.0 mm. Freehand acquisition of calibration data was performed smoothly using a magneto-optic hybrid sampling tool through a trocar under guidance by realtime 3-D monitoring of the tool trajectory; data acquisition time was less than 2 min. The present study suggests that our proposed method could correct for magnetic field distortion inside the patient's abdomen during a laparoscopic procedure within a clinically permissible period of time, as well as

  11. Application of a narrow-surface cage in full endoscopic minimally invasive transforaminal lumbar interbody fusion.

    PubMed

    He, Er-Xing; Guo, Jing; Ling, Qin-Jie; Yin, Zhi-Xun; Wang, Ying; Li, Ming

    2017-06-01

    Spinal endoscopy has been widely applied in lumbar discectomy and decompression. However, endoscopic lumbar interbody fusion still remains a technical challenge due to the limited space within the working trocar for cage implantation. The purpose of this study was to investigate the feasibility and effectiveness of using a narrow-surface fusion cage in full endoscopic minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for the treatment of lumbar degenerative disease. From Jun 2013 to Dec 2014, a total of 42 patients (23 males, 19 females) underwent full endoscopic MIS-TLIF at our hospital was recruited. An 8-mm-wide narrow-surface fusion cage was selected for all cases. Perioperative parameters and complications were recorded. Comparisons on visual analog scale (VAS) and oswestry disability index (ODI) scores before and after surgery were performed. At the last follow-up, Nakai grading system was applied to assess patients' satisfaction; meanwhile, interbody fusion was evaluated by computed tomography. Mean operation time was 233.1 ± 69.5 min, and mean blood loss during surgery was 221.8 ± 98.5 ml. Two patients (4.8%) developed neurological complications. Postoperative follow-up ranged from 24 to 36 months (mean 27.6 ± 3.8 months). VAS and ODI scores were significantly improved 3 months after surgery and at the final follow-up, respectively (P < 0.05). Outcome of surgery was graded as excellent for 32 patients, good for 8 patients, and acceptable for 2 patients, corresponding to a success rate ("good" and "excellent") of 95.2%. Thirty-nine of the 42 patients demonstrated solid interbody fusion at the last follow-up, indicating a fusion rate of 92.9%. Application of a narrow-surface fusion cage in full endoscopic MIS-TLIF for the treatment of lumbar degenerative disease is feasible and effective. The clinical outcome and fusion success of this procedure were acceptable and promising. Copyright © 2017 IJS Publishing Group Ltd

  12. Relative device stability of anterior versus axillary needle decompression for tension pneumothorax during casualty movement: Preliminary analysis of a human cadaver model.

    PubMed

    Leatherman, Matthew L; Held, Jenny M; Fluke, Laura M; McEvoy, Christian S; Inaba, Kenji; Grabo, Daniel; Martin, Matthew J; Earley, Angela S; Ricca, Robert L; Polk, Travis M

    2017-07-01

    Tension pneumothorax (tPTX) remains a significant cause of potentially preventable death in military and civilian settings. The current prehospital standard of care for tPTX is immediate decompression with a 14-gauge 8-cm angiocatheter; however, failure rates may be as high as 17% to 60%. Alternative devices, such as 10-gauge angiocatheter, modified Veress needle, and laparoscopic trocar, have shown to be potentially more effective in animal models; however, little is known about the relative insertional safety or mechanical stability during casualty movement. Seven soft-embalmed cadavers were intubated and mechanically ventilated. Chest wall thickness was measured at the second intercostal space at the midclavicular line (2MCL) and the fifth intercostal space along the anterior axillary line (5AAL). CO2 insufflation created a PTX, and needle decompression was then performed with a randomized device. Insertional depth was measured between hub and skin before and after simulated casualty transport. Thoracoscopy was used to evaluate for intrapleural placement and/or injury during insertion and after movement. Cadaver demographics, device displacement, device dislodgment, and injuries were recorded. Three decompressions were performed at each site (2MCL/5AAL), totaling 12 events per cadaver. Eighty-four decompressions were performed. Average cadaver age was 59 years, and body mass index was 24 kg/m. The CWT varied between cadavers because of subcutaneous emphysema, but the average was 39 mm at the 2MCL and 31 mm at the 5AAL. Following movement, the 2MCL site was more likely to become dislodged than the 5AAL (67% vs. 17%, p = 0.001). Median displacement also differed between 2MCL and 5AAL (23 vs. 2 mm, p = 0.001). No significant differences were noted in dislodgement or displacement between devices. Five minor lung injuries were noted at the 5AAL position. Preliminary results from this human cadaver study suggest the 5AAL position is a more stable and reliable location

  13. 2015 Summary Report on Industrial and Regulatory Engagement Activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, Kenneth David

    2015-09-01

    activities and future plans were made to Arizona Public Service, Exelon, Duke Energy, Pacific Gas & Electric, SCANA, Southern Nuclear, South Texas Project, STARS Alliance, Tennessee Valley Authority, and Xcel. Discussions were also held on the pathway goals and activities with major industry support organizations during FY 2102, including the Institute of Nuclear Power Operations (INPO), the Nuclear Information Technology Strategic Leadership (NITSL), the Nuclear Energy Institute (NEI), and the Electric Power Research Institute. The Advanced II&C Pathway work was presented at five major industry conferences and Informal discussions were held with key NRC managers at industry conferences. In addition, discussions were held with NRC senior managers on digital regulatory issues through participation on the NEI Digital I&C Working Group. Meetings were held with major industry suppliers and consultants, to explore opportunities for collaboration and to provide a means of pilot project technology transfer. In the international area, discussions were held with Electricite’ de France (EdF) concerning possible collaboration in the area NPP configuration control using intelligent wireless devices.« less

  14. Laparoscopic inguinal herniorrhaphy in children: a three-center experience with 933 repairs.

    PubMed

    Schier, Felix; Montupet, Philippe; Esposito, Ciro

    2002-03-01

    Laparoscopic inguinal herniorrhaphy has been introduced recently as an alternative to conventional open repair in children. This study was undertaken to evaluate the safety, efficacy, and reproducibility of this minimally invasive approach. A total of 933 laparoscopic inguinal herniorrhaphies were performed on 666 children (597 boys and 69 girls), ranging in age from 3 weeks to 14 years (median, 3.2 years). A 5-mm laparoscope was placed through an umbilical incision, and two 2-mm or 3-mm needle drivers were inserted through the lateral abdominal wall. The neck of the sac was closed with a 4-0 monofilament suture. The needle was inserted directly through the abdominal wall, and removed together with the trocar. Only the umbilical fascia was closed with an absorbable suture. No skin sutures were applied. A total of 911 indirect inguinal hernia sacs were closed (337 right, 172 left, 402 bilateral) and 22 direct inguinal hernias were repaired (14 boys, 3 girls; 11 right, 3 left, 4 bilateral). The median operating time was 22 minutes (range, unilateral, 7 to 45 min; bilateral, 9 to 51 min). With experience, this time gradually decreased. There were no intraoperative complications. The contralateral asymptomatic processus was unexpectedly open on the left side in 137 of the boys (23%) and 10 of the girls (15%), and on the right side in 131 of the boys (22%) and 21 of the girls (32%). In 16% of the children, the final procedure was modified on the basis of the anatomic findings. No hernia was found in 13 children (1.9%). The recurrence rate was 3.4% (follow-up time ranged from 2 months to 7 years). Hydroceles were observed in 4 children, and a subtle change in testicular position and size was noted in one boy. Laparoscopic inguinal repair in children proved safe and reproducible, although the recurrence rate was slightly higher than with the open approach. However, laparoscopy allows easy and precise identification of the type of defect and its correction. In this series

  15. A clinical evaluation of four non-Luer spinal needle and syringe systems.

    PubMed

    Kinsella, S M; Goswami, A; Laxton, C; Kirkham, L; Wharton, N; Bowen, M

    2012-11-01

    We performed an evaluation of non-Luer spinal devices supplied by four manufacturers or suppliers: Polymedic; Pajunk; Sarstedt; and Smiths. For each supplier, 100 evaluations were performed using a 25-G 90-mm spinal needle, 3-ml syringe, 5-ml syringe and filter needle; for comparison, 100 evaluations were performed with our standard Luer equipment. The non-Luer devices were associated with more qualitative problems compared with the Luer devices, for example, poor feel of dural puncture (9-32% vs 10%, respectively), poor observation of cerebrospinal fluid in the hub (3-27% vs 0%), and connection problem of the syringe to the spinal needle (7-33% vs 0%). There was also more frequent failure to achieve the spinal injection due to equipment-related causes (4-7% vs 0%, respectively). Median (IQR [range]) numeric satisfaction scores for the spinal needles were: Luer 10 (9-10 [7-10]); Polymedic 7 (4-8 [0-10]; Pajunk 7 (5-8 [0-10]); Sarstedt 7 (6-8 [0-10]); and Smiths 9 (7-10 [0-10]) (p<0.0001). Satisfaction scores for all spinal equipment were: Luer 10 (9-10 [5-10]); Polymedic 8 (6-8 [0-10]); Pajunk 7 (5-7 [1-9]); Sarstedt 8 (6-8 [0-10]); and Smiths 8 (8-9 [2-10]) (p<0.0001). Between 21% and 75% of non-Luer evaluations were rated with satisfaction worse than the usual Luer needle compared with 0-10% rated better, depending on the needle type. Between 22% and 76% of non-Luer evaluations were rated with satisfaction worse than the usual Luer equipment compared with 0-14% rated better. Specific concerns included poor feel of tissue planes and observation of cerebrospinal fluid (Polymedic), difficulty with connection of the syringe to the spinal needle and trocar removal (Pajunk), poor feel of tissue planes and needle flexibility (Sarstedt) and difficulty with connection of the syringe to the spinal needle (Smiths). We could not demonstrate a short-term learning curve for the new devices. Decisions on purchasing and implementation of the new non-Luer equipment will have to

  16. Full robot-assisted gastrectomy with intracorporeal robot-sewn anastomosis produces satisfying outcomes

    PubMed Central

    Liu, Xin-Xin; Jiang, Zhi-Wei; Chen, Ping; Zhao, Yan; Pan, Hua-Feng; Li, Jie-Shou

    2013-01-01

    AIM: To evaluate the feasibility and safety of full robot-assisted gastrectomy with intracorporeal robot hand-sewn anastomosis in the treatment of gastric cancer. METHODS: From September 2011 to March 2013, 110 consecutive patients with gastric cancer at the authors’ institution were enrolled for robotic gastrectomies. According to tumor location, total gastrectomy, distal or proximal subtotal gastrectomy with D2 lymphadenectomy was fully performed by the da Vinci Robotic Surgical System. All construction, including Roux-en-Y jejunal limb, esophagojejunal, gastroduodenal and gastrojejunal anastomoses were fully carried out by the intracorporeal robot-sewn method. At the end of surgery, the specimen was removed through a 3-4 cm incision at the umbilicus trocar point. The details of the surgical technique are well illustrated. The benefits in terms of surgical and oncologic outcomes are well documented, as well as the failure rate and postoperative complications. RESULTS: From a total of 110 enrolled patients, radical gastrectomy could not be performed in 2 patients due to late stage disease; 1 patient was converted to laparotomy because of uncontrollable hemorrhage, and 1 obese patient was converted due to difficult exposure; 2 patients underwent extra-corporeal anastomosis by minilaparotomy to ensure adequate tumor margin. Robot-sewn anastomoses were successfully performed for 12 proximal, 38 distal and 54 total gastrectomies. The average surgical time was 272.52 ± 53.91 min and the average amount of bleeding was 80.78 ± 32.37 mL. The average number of harvested lymph nodes was 23.1 ± 5.3. All specimens showed adequate surgical margin. With regard to tumor staging, 26, 32 and 46 patients were staged as I, II and III, respectively. The average hospitalization time after surgery was 6.2 d. One patient experienced a duodenal stump anastomotic leak, which was mild and treated conservatively. One patient was readmitted for intra-abdominal infection and was

  17. Robot-assisted, single-site, dismembered pyeloplasty for ureteropelvic junction obstruction with the new da Vinci platform: a stage 2a study.

    PubMed

    Buffi, Nicolò Maria; Lughezzani, Giovanni; Fossati, Nicola; Lazzeri, Massimo; Guazzoni, Giorgio; Lista, Giuliana; Larcher, Alessandro; Abrate, Alberto; Fiori, Cristian; Cestari, Andrea; Porpiglia, Francesco

    2015-01-01

    Laparoendoscopic single-site surgery (LESS) has gained popularity in urology over the last few years. To report a stage 2a study of robot-assisted single-site (R-LESS) pyeloplasty for ureteropelvic junction obstruction (UPJO). This study is an investigative pilot study of 30 consecutive cases of R-LESS pyeloplasty performed at two participating institutions between July 2011 and September 2013. Dismembered R-LESS pyeloplasty was performed at two surgical centers. Feasibility (conversion rate), safety (complication rate and Clavien-Dindo classification), efficacy (clinical outcome) of the procedure were assessed. The median patient age was 37 yr (range: 19-65 yr) and median body mass index was 23 kg/m(2) (range: 19-29 kg/m(2)). The median operative time was 160 min (range: 101-300 min), the median postoperative stay was 5 d (range: 3-13 d), and the median time to catheter removal was 3 d (range: 2-10). Two cases required conversion, the first one to standard laparoscopic technique and the second one to standard robotic technique. No intraoperative complications were reported. In three cases, an additional 5-mm trocar was needed. The postoperative complications rate was 26% (n=8). Most of them were grade 1 complications (n=4; 13%), followed by grade 2 (n=3; 10%) and grade 3 (n=1; 3.3%) complications, according to the Clavien-Dindo classification. One patient needed a surgical reintervention with standard robotic technique 3 d after surgery for urinary leakage. The overall success rate, considered as the resolution of symptoms and the absence of functional impairment at postoperative imaging, was 93.3% (n=28) at a median follow-up of 13 mo (range: 3-21 mo). The main limitations of this study are the limited number of patients included and the short-term follow-up. Single-site robotic pyeloplasty is a feasible technique in selected patients, with good cosmetic results and excellent short-term clinical outcomes. Prospective studies are needed to further assess its role

  18. Revolutionizing (robot-assisted) laparoscopic gamma tracing using a drop-in gamma probe technology

    PubMed Central

    van Oosterom, Matthias N; Simon, Hervé; Mengus, Laurent; Welling, Mick M; van der Poel, Henk G; van den Berg, Nynke S; van Leeuwen, Fijs WB

    2016-01-01

    In complex (robot-assisted) laparoscopic radioguided surgery procedures, or when low activity lesions are located nearby a high activity background, the limited maneuverability of a laparoscopic gamma probe (LGP; 4 degrees of freedom (DOF)) may hinder lesion identification. We investigated a drop-in gamma probe (DIGP) technology to be inserted via a trocar, after which the laparoscopic surgical tool at hand can pick it up and maneuver it. Phantom experiments showed that distinguishing a low objective from a high background source (1:100 ratio) was only possible with the detector faced >90° from the high background source. Signal-low-objective-to-background ratios of 3.77, 2.01 and 1.84 were found for detector angles of 90°, 135° and 180°, respectively, whereas detector angles of 0° and 45° were unable to distinguish the sources. This underlines the critical role probe positioning plays. We then focused on engineering of the gripping part for optimal DIGP pick-up with a conventional laparoscopic forceps (4 DOF) or a robotic forceps (6 DOF). DIGPs with 0°, 45°, 90°, and 135° -grip orientations were designed, and their maneuverability- and scanning direction were evaluated and compared to a conventional LGP. The maneuverability- and scanning direction of the DIGP was found highest when using the robotic forceps, with the largest effective scanning direction range obtained with the 90° -grip design (0-180° versus 0-111°, 0-140°, and 37-180° for 0°, 45° and 135° -grip designs, respectively). For the laparoscopic forceps, the scan direction directly translated from the angle of the grip design with the advantage that the 135° -gripped DIGP could be faced backwards (not possible with the conventional LGP). In the ex vivo clinical setup, the surgeon rated DIGP pick-up most convenient for the 45°-grip design. Concluding, the DIGP technology was successfully introduced. Optimization of the grip design and grasping angle of the DIGP increased its utility

  19. General surgery residents' perception of robot-assisted procedures during surgical training.

    PubMed

    Farivar, Behzad S; Flannagan, Molly; Leitman, I Michael

    2015-01-01

    With the continued expansion of robotically assisted procedures, general surgery residents continue to receive more exposure to this new technology as part of their training. There are currently no guidelines or standardized training requirements for robot-assisted procedures during general surgical residency. The aim of this study was to assess the effect of this new technology on general surgery training from the residents' perspective. An anonymous, national, web-based survey was conducted on residents enrolled in general surgery training in 2013. The survey was sent to 240 Accreditation Council for Graduate Medical Education-approved general surgery training programs. Overall, 64% of the responding residents were men and had an average age of 29 years. Half of the responses were from postgraduate year 1 (PGY1) and PGY2 residents, and the remainder was from the PGY3 level and above. Overall, 50% of the responses were from university training programs, 32% from university-affiliated programs, and 18% from community-based programs. More than 96% of residents noted the availability of the surgical robot system at their training institution. Overall, 63% of residents indicated that they had participated in robotic surgical cases. Most responded that they had assisted in 10 or fewer robotic cases with the most frequent activities being assisting with robotic trocar placement and docking and undocking the robot. Only 18% reported experience with operating the robotic console. More senior residents (PGY3 and above) were involved in robotic cases compared with junior residents (78% vs 48%, p < 0.001). Overall, 60% of residents indicated that they received no prior education or training before their first robotic case. Approximately 64% of residents reported that formal training in robotic surgery was important in residency training and 46% of residents indicated that robotic-assisted cases interfered with resident learning. Only 11% felt that robotic-assisted cases

  20. Robotic right colectomy for hemorrhagic right colon cancer: a case report and review of the literature of minimally invasive urgent colectomy.

    PubMed

    Felli, Emanuele; Brunetti, Francesco; Disabato, Mara; Salloum, Chady; Azoulay, Daniel; De'angelis, Nicola

    2014-01-01

    Right colon cancer rarely presents as an emergency, in which bowel occlusion and massive bleeding are the most common clinical presentations. Although there are no definite guidelines, the first line treatment for massive right colon cancer bleeding should ideally stop the bleeding using endoscopy or interventional radiology, subsequently allowing proper tumor staging and planning of a definite treatment strategy. Minimally invasive approaches for right and left colectomy have progressively increased and are widely performed in elective settings, with laparoscopy chosen in the majority of cases. Conversely, in emergent and urgent surgeries, minimally invasive techniques are rarely performed. We report a case of an 86-year-old woman who was successfully treated for massive rectal bleeding in an urgent setting by robotic surgery (da Vinci Intuitive Surgical System®). At admission, the patient had severe anemia (Hb 6 g/dL) and hemodynamic stability. A computer tomography scanner with contrast enhancement showed a right colon cancer with active bleeding; no distant metastases were found. A colonoscopy did not show any other bowel lesion, while a constant bleeding from the right pre-stenotic colon mass was temporarily arrested by endoscopic argon coagulation. A robotic right colectomy in urgent setting (within 24 hours from admission) was indicated. A three-armed robot was used with docking in the right side of the patient and a fourth trocar for the assistant surgeon. Because of the patient's poor nutritional status, a double-barreled ileocolostomy was performed. The post-operative period was uneventful. As the neoplasia was a pT3N0 adenocarcinoma, surveillance was decided after a multidisciplinary meeting, and restoration of the intestinal continuity was performed 3 months later, once good nutritional status was achieved. In addition, we reviewed the current literature on minimally invasive colectomy performed for colon carcinoma in emergent or urgent setting. No

  1. New laparoscopic procedure for left-sided pancreatic cancer-artery-first approach laparoscopic RAMPS using 3D technique.

    PubMed

    Yamamoto, Michihiro; Zaima, Masazumi; Yamamoto, Hidekazu; Harada, Hideki; Kawamura, Junichiro; Yamada, Masahiro; Yazawa, Tekefumi; Kawasoe, Junya

    2017-12-02

    For left-sided pancreatic ductal adenocarcinoma (PDAC), radical antegrade modular pancreatosplenectomy (RAMPS) is a reasonable surgical approach for tumor-free margin resection and systemic lymph node clearance. In pancreaticoduodenectomy for PDAC, the superior mesenteric artery (SMA)-first approach (or the "artery-first approach") has become the standard procedure. With improvements in laparoscopic instruments and techniques, some surgeons attempted to apply laparoscopic RAMPS (L-RAMPS) for carefully selected patients with left-sided PDAC. However, owing to several technical difficulties in this procedure, its application remains uncommon. Moreover, the artery-first approach in L-RAMPS has not been reported. Here, we developed the artery-first approach L-RAMPS for left-sided PDAC and have presented the same in this report. Between June 2014 and July 2015, 16 patients with left-sided PDAC were referred to our division for pancreatic resection. The following technique was used for performing L-RAMPS on 3 of the 16 patients (19%). Six trocars were placed. After opening the omental bursa, only the middle segment of the pancreas was initially separated from both the left renal vein and the SMA. We termed this procedure as the "artery-first approach using a dome-shaped dorsomedial dissection (3D) technique." This 3D technique enabled the interruption of the entire arterial supply to the specimen while preserving the venous drainage through the splenic vein for preventing venous congestion. The technique also contributed to the early detection of no tumor infiltration into the SMA and the early determination of posterior dissection plane. After pancreatic neck transection, the splenic artery and vein were divided. Finally, the pancreatic tail and spleen were dissected in a right-to-left direction. All operations were completed without any intraoperative complications. The median blood loss and retrieved lymph node count were 75 mL and 37, respectively, which were

  2. Opportunity to Plug Your Car Into the Electric Grid is Arriving

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Griego, G.

    2010-06-01

    Plug-in hybrid electric vehicles are hitting the U.S. market for the first time this year. Similar to hybrid electric vehicles, they feature a larger battery and plug-in charger that allows consumers to replace a portion of their fossil fuel by simply plugging their cars into standard 110-volt outlets at home or wherever outlets are available. If these vehicles become widely accepted, consumers and the environment will benefit, according to a computer modeling study by Xcel Energy and the Department of Energy's National Renewable Energy Laboratory. Researchers found that each PHEV would cut carbon dioxide emissions in half and save ownersmore » up to $450 in annual fuel costs and up to 240 gallons of gasoline. The study also looked at the impact of PHEVs on the electric grid in Colorado if used on a large scale. Integrating large numbers of these vehicles will depend on the adoption of smart-grid technology - adding digital elements to the electric power system to improve efficiency and enable more dynamic communication between consumers and producers of electricity. Using an intelligent monitoring system that keeps track of all electricity flowing in the system, a smart grid could enable optimal PHEV battery-charging much the same way it would enable users to manage their energy use in household appliances and factory processes to reduce energy costs. When a smart grid is implemented, consumers will have many low-cost opportunities to charge PHEVs at different times of the day. Plug-in vehicles could contribute electricity at peak times, such as summer evenings, while taking electricity from the grid at low-use times such as the middle of the night. Electricity rates could offer incentives for drivers to 'give back' electricity when it is most needed and to 'take' it when it is plentiful. The integration of PHEVs, solar arrays and wind turbines into the grid at larger scales will require a more modern electricity system. Technology already exists to allow

  3. Immersive training and mentoring for laparoscopic surgery

    NASA Astrophysics Data System (ADS)

    Nistor, Vasile; Allen, Brian; Dutson, E.; Faloutsos, P.; Carman, G. P.

    2007-04-01

    We describe in this paper a training system for minimally invasive surgery (MIS) that creates an immersive training simulation by recording the pathways of the instruments from an expert surgeon while performing an actual training task. Instrument spatial pathway data is stored and later accessed at the training station in order to visualize the ergonomic experience of the expert surgeon and trainees. Our system is based on tracking the spatial position and orientation of the instruments on the console for both the expert surgeon and the trainee. The technology is the result of recent developments in miniaturized position sensors that can be integrated seamlessly into the MIS instruments without compromising functionality. In order to continuously monitor the positions of laparoscopic tool tips, DC magnetic tracking sensors are used. A hardware-software interface transforms the coordinate data points into instrument pathways, while an intuitive graphic user interface displays the instruments spatial position and orientation for the mentor/trainee, and endoscopic video information. These data are recorded and saved in a database for subsequent immersive training and training performance analysis. We use two 6 DOF DC magnetic trackers with a sensor diameter of just 1.3 mm - small enough for insertion into 4 French catheters, embedded in the shaft of a endoscopic grasper and a needle driver. One sensor is located at the distal end of the shaft while the second sensor is located at the proximal end of the shaft. The placement of these sensors does not impede the functionally of the instrument. Since the sensors are located inside the shaft there are no sealing issues between the valve of the trocar and the instrument. We devised a peg transfer training task in accordance to validated training procedures, and tested our system on its ability to differentiate between the expert surgeon and the novices, based on a set of performance metrics. These performance metrics

  4. Robotic laparoscopic surgery: cost and training.

    PubMed

    Amodeo, A; Linares Quevedo, A; Joseph, J V; Belgrano, E; Patel, H R H

    2009-06-01

    The advantages of minimally invasive surgery are well accepted. Shorter hospital stays, decreased postoperative pain, rapid return to preoperative activity, decreased postoperative ileus, and preserved immune function are among the benefits of the laparoscopic approach. However, the instruments of laparoscopy afford surgeons limited precision and poor ergonomics, and their use is associated with a significant learning curve and the amount of time and energy necessary to develop and maintain such advanced laparoscopic skills is not insignificant. The robotic surgery allows all laparoscopists to perform advanced laparoscopic procedures with greater ease. The potential advantages of surgical robotic systems include making advanced laparoscopic surgical procedures accessible to surgeons who do not have advanced video endoscopic training and broadening the scope of surgical procedures that can be performed using the laparoscopic method. The wristed instruments, x10 magnifications, tremor filtering, scaling of movements and three-dimensional view allow the urologist to perform the intricate dissection and anastomosis with high precision. The robot is not, however, without significant disadvantages as compared with traditional laparoscopy. These include greater expense and consumption of operating room resources such as space and the availability of skilled technical staff, complete elimination of tactile feedback, and more limited options for trocar placement. The current cost of the da Vinci system is $ 1.2 million and annual maintenance is $ 138000. Many studies suggest that depreciation and maintenance costs can be minimised if the number of robotic cases is increased. The high cost of purchasing and maintaining the instruments of the robotic system is one of its many disadvantages. The availability of the robotic systems to only a limited number of centres reduces surgical training opportunities. Hospital administrators and surgeons must define the reasons for

  5. Assessment of adhesion formation to intra-abdominal polypropylene mesh and polytetrafluoroethylene mesh.

    PubMed

    Matthews, Brent D; Pratt, Broc L; Pollinger, Harrison S; Backus, Charles L; Kercher, Kent W; Sing, R F; Heniford, B Todd

    2003-10-01

    The development of intra-abdominal adhesions, bowel obstruction, and enterocutaneous fistulas are potentially severe complications related to the intraperitoneal placement of prosthetic biomaterials. The purpose of this study was to determine the natural history of adhesion formation to polypropylene mesh and two types of polytetrafluoroethylene (ePTFE) mesh when placed intraperitoneally in a rabbit model that simulates laparoscopic ventral hernia repair. Thirty New Zealand white rabbits were used for this study. A 10-cm midline incision was performed for intra-abdominal access and a 2 cm x 2 cm piece of mesh (n = 60) was sewn to an intact peritoneum on each side of the midline. Two types of ePTFE mesh (Dual Mesh and modified Dual Mesh, W.L. Gore & Assoc., Flagstaff, AZ) and polypropylene mesh were compared. The rate of adhesion formation was evaluated by direct visualization using microlaparoscopy (2-mm endoscope/trocar) at 7 days, 3 weeks, 9 weeks, and 16 weeks after mesh implantation. Adhesions to the prosthetic mesh were scored for extent (%) using the Modified Diamond Scale (0 = 0%, 1 50%). At necropsy the mesh was excised en bloc with the anterior abdominal wall for histological evaluation of mesothelial layer growth. The mean adhesion score for the polypropylene mesh was significantly greater (P < 0.05) than Dual Mesh at 9 weeks and 16 weeks and modified Dual Mesh at 7 days, 9 weeks, and 16 weeks. Fifty-five percent (n = 11) of the polypropylene mesh had adhesions to small intestine or omentum at necropsy compared to 30% (n = 6) of the Dual Mesh and 20% (n = 4) of the modified Dual Mesh. There was a significantly greater percentage (P < 0.003) of ePTFE mesh mesothelialized at explant (modified Dual Mesh 44.2%; Dual Mesh 55.8%) compared to the polypropylene mesh (12.9%). Serial microlaparoscopic evaluation of intraperitoneally implanted polypropylene mesh and ePTFE mesh in a rabbit model revealed a progression of adhesions to

  6. Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis.

    PubMed

    Targarona, Eduardo Ma; Balague, Carmen; Marin, Juan; Neto, Rene Berindoague; Martinez, Carmen; Garriga, Jordi; Trias, Manuel

    2005-12-01

    The development of operative laparoscopic surgery is linked to advances in ancillary surgical instrumentation. Ultrasonic energy devices avoid the use of electricity and provide effective control of small- to medium-sized vessels. Bipolar computer-controlled electrosurgical technology eliminates the disadvantages of electrical energy, and a mechanical blade adds a cutting action. This instrument can provide effective hemostasis of large vessels up to 7 mm. Such devices significantly increase the cost of laparoscopic procedures, however, and the amount of evidence-based information on this topic is surprisingly scarce. This study compared the effectiveness of three different energy sources on the laparoscopic performance of a left colectomy. The trial included 38 nonselected patients with a disease of the colon requiring an elective segmental left-sided colon resection. Patients were preoperatively randomized into three groups. Group I had electrosurgery; vascular dissection was performed entirely with an electrosurgery generator, and vessels were controlled with clips. Group II underwent computer-controlled bipolar electrosurgery; vascular and mesocolon section was completed by using the 10-mm Ligasure device alone. In group III, 5-mm ultrasonic shears (Harmonic Scalpel) were used for bowel dissection, vascular pedicle dissection, and mesocolon transection. The mesenteric vessel pedicle was controlled with an endostapler. Demographics (age, sex, body mass index, comorbidity, previous surgery and diagnoses requiring surgery) were recorded, as were surgical details (operative time, conversion, blood loss), additional disposable instruments (number of trocars, EndoGIA charges, and clip appliers), and clinical outcome. Intraoperative economic costs were also evaluated. End points of the trial were operative time and intraoperative blood loss, and an intention-to-treat principle was followed. The three groups were well matched for demographic and pathologic features

  7. Input and output for surgical simulation: devices to measure tissue properties in vivo and a haptic interface for laparoscopy simulators.

    PubMed

    Ottensmeyer, M P; Ben-Ur, E; Salisbury, J K

    2000-01-01

    deformations. Both devices are designed to pass through standard 12 mm laparoscopy trocars, and will be suitable for use during open or minimally invasive procedures. We plan to acquire data from pigs used by surgeons for training purposes, but conceivably, the tools could be refined for use on humans undergoing surgery. Our work will provide the necessary data input for surgical simulations to accurately model the force interactions that a surgeon would have with tissue, and will provide the force output to create a truly realistic simulation of minimally invasive surgery.

  8. Reconstruction of the esophagojejunostomy by double stapling method using EEA™ OrVil™ in laparoscopic total gastrectomy and proximal gastrectomy

    PubMed Central

    2011-01-01

    Here we report the method of anastomosis based on double stapling technique (hereinafter, DST) using a trans-oral anvil delivery system (EEATM OrVilTM) for reconstructing the esophagus and lifted jejunum following laparoscopic total gastrectomy or proximal gastric resection. As a basic technique, laparoscopic total gastrectomy employed Roux-en-Y reconstruction, laparoscopic proximal gastrectomy employed double tract reconstruction, and end-to-side anastomosis was used for the cut-off stump of the esophagus and lifted jejunum. We used EEATM OrVilTM as a device that permitted mechanical purse-string suture similarly to conventional EEA, and endo-Surgitie. After the gastric lymph node dissection, the esophagus was cut off using an automated stapler. EEATM OrVilTM was orally and slowly inserted from the valve tip, and a small hole was created at the tip of the obliquely cut-off stump with scissors to let the valve tip pass through. Yarn was cut to disconnect the anvil from a tube and the anvil head was retained in the esophagus. The end-Surgitie was inserted at the right subcostal margin, and after the looped-shaped thread was wrapped around the esophageal stump opening, assisting Maryland forceps inserted at the left subcostal and left abdomen were used to grasp the left and right esophageal stump. The surgeon inserted anvil grasping forceps into the right abdomen, and after grasping the esophagus with the forceps, tightened the end Surgitie, thereby completing the purse-string suture on the esophageal stump. The main unit of the automated stapler was inserted from the cut-off stump of the lifted jejunum, and a trocar was made to pass through. To prevent dropout of the small intestines from the automated stapler, the automated stapler and the lifted jejunum were fastened with silk thread, the abdomen was again inflated, and the lifted jejunum was led into the abdominal cavity. When it was confirmed that the automated stapler and center rod were made completely linear

  9. Effects of dietary addition of capsicum extract on intake, water consumption, and rumen fermentation of fattening heifers fed a high-concentrate diet.

    PubMed

    Rodríguez-Prado, M; Ferret, A; Zwieten, J; Gonzalez, L; Bravo, D; Calsamiglia, S

    2012-06-01

    Four beef Holstein heifers (BW = 438 ± 71 kg) fitted with a 1-cm i.d. plastic ruminal trocars were used in a 4 × 4 Latin square design to evaluate the effect of 3 doses of capsicum extract (CAP) on intake, water consumption, and ruminal fermentation in heifers fed a high-concentrate diet. Animals were fed (DM basis) 10% barley straw and 90% concentrate (32.2% barley grain, 27.9% ground corn, 7.5% wheat bran, 10.7% soybean meal, 10.7% soybean hulls, 7.2% corn gluten feed, 3.1% mineral-vitamin mix; 16.6% CP, 18.3% NDF). Treatments were no additive (CTR), 125 (CAP125), 250 (CAP250), and 500 (CAP500) mg/d of capsicum oleoresin standardized with 6% of capsaicin and dihydrocapsaicin (XTract 6933, Pancosma, Geneva, Switzerland). Each experimental period consisted of 25 d (15 d for adaptation, 5 d of continuous measurement of DMI, and 3 d for rumen sample collection). Animals had ad libitum access to water and feed offered once daily at 0800 h. Data were analyzed by the MIXED procedure of SAS. The model included the fixed effects of period and treatment, the random effect of heifer, and the residual error. The effects were tested for linear and quadratic effects. A linear response was observed (CTR, CAP125, CAP250, and CAP500, respectively) for DMI (8.56, 9.84, 8.68, and 9.40 kg/d; P < 0.04), ruminal pH (6.03, 5.84, 5.96, and 5.86; P < 0.08) and total VFA (134.3, 144.8, 140.1, and 142.8 mM; P < 0.08). There was a strong correlation between water consumption and DMI (R(2) = 0.98). Dry matter intake in the first 2 h after feeding was reduced (P < 0.05) in all CAP treatments compared with control. The molar proportion of acetate tended to decrease linearly (from 59.6 to 55.5 mol/100 mol; P < 0.06), and ammonia N concentration tended to increase linearly (from 14.4 to 16.0 mg N/dL; P < 0.08). In contrast, the molar proportion of propionate (23.8 mol/100 mol), butyrate (14.2 mol/100 mol), and lactate (0.28 mol/100 mol) were not affected by treatments. Results indicate that

  10. A 5-year experience with a minimally invasive technique for pectus carinatum repair.

    PubMed

    Abramson, Horacio; D'Agostino, José; Wuscovi, Sebastián

    2009-01-01

    This report describes a 5-year experience with a novel, minimally invasive surgical technique for treatment of pectus carinatum. From June 2002 to August 2007, 40 patients underwent operation to correct pectus carinatum by pressure applied through a curved steel bar that was placed subcutaneously anterior to the sternum, via lateral thoracic incisions. The bar is inserted through a polyvinyl chloride tube with the convexity facing posteriorly. The polyvinyl chloride tube is positioned presternally by trocar. Subperiosteal wires attach small fixation plates to the ribs laterally, and the convex bar is secured to the small fixation plates with screws applying manual pressure to the anterior chest wall until the desired configuration is achieved. The compressive elongated bar is attached to the fixation plate with screws. The average age was 14.3 years (range, 10-21 years), and 90% were male. Both symmetric and asymmetric protrusions were treated. Patients whose chest was not malleable, and whose sternum could not be brought to a desirable position with pressure from the operator's hand, were treated by the open or "Ravitch" technique. After 2 or more years, the bar, wires stitches, screws, and fixation plates were removed. Of 40 patients treated with this procedure, 20 have undergone bar removal with the following results: 10 excellent, 4 good, 4 fair, and 2 poor. Average blood loss was 15 mL. Average length of hospital stay was as follows: implant, 3.8 days; removal, 1.4 days. Patients returned to routine activity 14 days after repair. Average follow-up since primary repair is 2.49 years. In those who have had bar removal, it is 1.53 years. Complications were pneumothorax in 1 patient, treated with chest tub e suction; skin adherence in 8 cases; seroma in 6; wire breakage in 3; persistence of pain in 1; and infection in 1. Technical modifications (selecting younger patients, excluding patients with a stiff thoracic wall, submuscular insertion of the bar, stronger

  11. An Optimal Approach for Laparoscopic D3 Lymphadenectomy Plus Complete Mesocolic Excision (D3+CME) for Right-Sided Colon Cancer.

    PubMed

    Xie, Daxing; Yu, Chaoran; Gao, Chun; Osaiweran, Hasan; Hu, Junbo; Gong, Jianping

    2017-05-01

    It is common knowledge that high ligation of blood vessels at the D3 level and complete mesocolic excision (CME) are two critical points of right hemicolectomy for right colon cancer (RCC). 1-5 To date, a safe strategy for completing these two procedures under laparoscopic surgery has not been extensively described. The authors provide a video to demonstrate laparoscopic right hemicolectomy (D3 + CME) with an optimal mesentery-defined approach. By identifying three "tri-junctions," this approach facilitates dissection of the entire mesocolon along the embryologic planes as far centrally as possible and enables the high tie of feeding vessels at bifurcation. The authors propose that this approach is safe, decreases blood loss, and is a secure method for right colon cancer intervention. Between June 2014 and June 2015, the study recruited 36 patients with informed consent, and these patients underwent laparoscopic D3+CME for right colon cancer by a single surgeon. All the participants provided informed written consent to participate in the study. This study was approved by the Tongji Hospital Ethics Committee. The patients' demographics, oncologic charac- teristics, postoperative outcomes within 30 days, and follow-up data were collected. The perioperative outcomes included blood lost, number of retrieved lymph nodes, postoperative hospital length of stay, and morbidity. The postoperative 30-day morbidity included cardiovascular, pulmonary, and urinary complications, as well as wound infection, anastomotic leakage, and postoperative ileus. The complications were diagnosed and categorized based on relevant clinical manifestations. For this procedure, all patients are placed in the Trendelenburg position, with five trocars inserted. Carbon dioxide (CO 2 ) is inflated through the intraumbilical trocar, maintaining steady intraabdominal pressure. The operating surgeon stands between the patient's legs, with the camera holder on the left and the assistant on the right

  12. Unicameral bone cyst: radiographic assessment of venous outflow by cystography as a prognostic index.

    PubMed

    Ramirez, Ana; Abril, Juan Carlos; Touza, Alberto

    2012-11-01

    of the first injection were not significant factors of healing (P=0.4). The average follow-up time was 59 months (24-60 months). Cystography provides morphological and functional information of simple bone cyst. It is a useful test before the administration of percutaneous injections of sclerosing substances. It facilitates the differentiation of cysts that may achieve complete healing (negative venogram) from those that tend to show recurrence (rapid venous outflow). Therapeutic material should be introduced slowly and a second trocar should always be placed to decrease the risk of migration in cysts with communication with the venous system. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

  13. Adhesive complex coacervate inspired by the sandcastle worm as a sealant for fetoscopic defects

    NASA Astrophysics Data System (ADS)

    Kaur, Sarbjit

    Inspired by the Sandcastle Worm, biomimetic of the water-borne adhesive was developed by complex coacervation of the synthetic copolyelectrolytes, mimicking the chemistries of the worm glue. The developed underwater adhesive was designed for sealing fetal membranes after fetoscopic surgery in twin-to-twin transfusion syndrome (TTTS) and sealing neural tissue of a fetus in aminiotic sac for spina bifida condition. Complex coacervate with increased bond strength was created by entrapping polyethylene glycol diacrylate (PEG-dA) monomer within the cross-linked coacervate network. Maximum shear bond strength of ~ 1.2 MPa on aluminum substrates was reached. The monomer-filled coacervate had complex flow behavior, thickening at low shear rates and then thinning suddenly with a 16-fold drop in viscosity at shear rates near 6 s-1. The microscale structure of the complex coacervates resembled a three-dimensional porous network of interconnected tubules. This complex coacervate adhesive was used in vitro studies to mimic the uterine wall-fetal membrane interface using a water column with one end and sealed with human fetal membranes and poultry breast, and a defect was created with an 11 French trocar. The coacervate adhesive in conjunction with the multiphase adhesive was used to seal the defect. The sealant withstood an additional traction of 12 g for 30-60 minutes and turbulence of the water column without leakage of fluid or slippage. The adhesive is nontoxic when in direct contact with human fetal membranes in an organ culture setting. A stable complex coacervate adhesive for long-term use in TTTS and spina bifida application was developed by methacrylating the copolyelectrolytes. The methacrylated coacervate was crosslinked chemically for TTTS and by photopolymerization for spina bifida. Tunable mechanical properties of the adhesive were achieved by varying the methacrylation of the polymers. Varying the amine to phosphate (A/P) ratio in the coacervate formation

  14. [Comparison of hysterectomy techniques in a group of patient operated for the diagnosis female to male transsexualism].

    PubMed

    Filová, P; Halaška, M; Sehnal, B; Otčenášek, M

    2014-01-01

    healing. Postoperative complication after TLH included 4 times bleeding from vaginal suture, once haematoma in Douglas pouch, once seroma in the place of trocar insertion, once subileus. Once ureter was injured and treated by the ureteral stent insertion. Complication after AHL and LAVH were not recognised. Total laparoscopic hysterectomy is the method of choice in the group of FtM transsexuals. This technique could be used also in nuliparous women with long and narrow vagina. Compared with laparotomic approach lower blood loss and shorter hospital stay was proved. Earlier restitution of full activity is another advantage. Musculus rectus abdominis flap can be used for phallus construction. The only significant disadvantage is a longer duration of surgery.

  15. Robot-assisted renal transplantation using the retroperitoneal approach (RART) with more than one year follow up: Description of the technique and results.

    PubMed

    Bruyère, F; Pradère, B; Faivre d'Arcier, B; Boutin, J-M; Buchler, M; Brichart, N

    2018-01-01

    To describe the technique and report our first experience of robotic-assisted renal transplantation (RART) with more than one year follow up. In our center the first case of RART was realized in October 2013 with a cadaveric graft. We used the combined extra- and intraperitoneal robot assisted laparoscopic route with extraperitoneal positioning of the graft and intraperitoneal transplantation. The patient was placed in the supine position with arms along the body; the robot came from the right inferior part of the patient. Access to the retroperitoneal space was obtained using an Alexis trocar that permitted the insertion of the kidney with ice without losing the pneumoperitoneum. Ports included a 12-mm camera port (placed under the ombilicus), two 8-mm robotic ports (placed 6cms laterally from the previous port) and a 12-mm assistant port (placed between the upper port and the ombilic). All the pre-, per- and postoperative data were prospectively included in a database. We report the results of the initial experience of RART, performed with more than one year follow-up. This technique is the first described using the retroperitoneal approach that is the routine approach for conventional open renal transplantation. This approach permitted to perform excellent arterial, veinous and ureteral anastomosis. Eight cases of RART were conducted between October 2013 and November 2015 (five men and three women). The average age was 58 years (range 39-75years). The average body mass index was 28 (range 22-38). Five patients had history of abdominal surgery and were dialyzed for 30 months on average (range 3-63months). Three left and five right cadavers kidneys were transplanted in the right iliac fossa. The mean graft size was 109mm (range 90-130). The mean length of the incision for insertion of the graft was 60 mms (40-100mms). Mean warm ischemia time was 63minutes (range 46-84). The total operative time was 200minutes (149-245). No patient was transfused during surgery and

  16. Imaging of implant needles for real-time HDR-brachytherapy prostate treatment using biplane ultrasound transducers.

    PubMed

    Siebert, Frank-André; Hirt, Markus; Niehoff, Peter; Kovács, György

    2009-08-01

    Ultrasound imaging is becoming increasingly important in prostate brachytherapy. In high-dose-rate (HDR) real-time planning procedures the definition of the implant needles is often performed by transrectal ultrasound. This article describes absolute measurements of the visibility and accuracy of manual detection of implant needle tips and compares measurement results of different biplane ultrasound systems in transversal and longitudinal (i.e., sagittal) ultrasound modes. To obtain a fixed coordinate system and stable conditions the measurements were carried out in a water tank using a dedicated marker system. Needles were manually placed in the phantom until the observer decided by the real-time ultrasound image that the zero position was reached. A comparison of three different ultrasound systems yielded an offset between 0.8 and 3.1 mm for manual detection of the needle tip in ultrasound images by one observer. The direction of the offset was discovered to be in the proximal direction, i.e., the actual needle position was located more distally compared to the ultrasound-based definition. In the second part of the study, the ultrasound anisotropy of trocar implant needles is reported. It was shown that the integrated optical density in a region of interest around the needle tip changes with needle rotation. Three peaks were observed with a phase angle of 120 degrees. Peaks appear not only in transversal but also in longitudinal ultrasound images, with a phase shift of 60 degrees. The third section of this study shows results of observer dependent influences on needle tip detection in sagittal ultrasound images considering needle rotation. These experiments were carried out using the marker system in a water tank. The needle tip was placed exactly at the position z=0 mm. It was found that different users tend to differently interpret the same ultrasound images. The needle tip was manually detected five times in the ultrasound images by three experienced observers

  17. Liposomal bupivacaine decreases pain following retropubic sling placement: a randomized placebo-controlled trial.

    PubMed

    Mazloomdoost, Donna; Pauls, Rachel N; Hennen, Erin N; Yeung, Jennifer Y; Smith, Benjamin C; Kleeman, Steven D; Crisp, Catrina C

    2017-11-01

    Midurethral slings are commonly used to treat stress urinary incontinence. Pain control, however, may be a concern. Liposomal bupivacaine is a local anesthetic with slow release over 72 hours, demonstrated to lower pain scores and decrease narcotic use postoperatively. The purpose of this study was to examine the impact of liposomal bupivacaine on pain scores and narcotic consumption following retropubic midurethral sling placement. This randomized, placebo-controlled trial enrolled women undergoing retropubic midurethral sling procedures with or without concomitant anterior or urethrocele repair. Subjects were allocated to receive liposomal bupivacaine (intervention) or normal saline placebo injected into the trocar paths and vaginal incision at the conclusion of the procedure. At the time of drug administration, surgeons became unblinded, but did not collect outcome data. Participants remained blinded to treatment. Surgical procedures and perioperative care were standardized. The primary outcome was the visual analog scale pain score 4 hours after discharge home. Secondary outcomes included narcotic consumption, time to first bowel movement, and pain scores collected in the mornings and evenings until postoperative day 6. The morning pain item assessed "current level of pain"; the evening items queried "current level of pain," "most intense pain today," "average pain today with activity," and "average pain today with rest." Likert scales were used to measure satisfaction with pain control at 1- and 2-week postoperative intervals. Sample size calculation deemed 52 subjects per arm necessary to detect a mean difference of 10 mm on a 100-mm visual analog scale. To account for 10% drop out, 114 participants were needed. One hundred fourteen women were enrolled. After 5 exclusions, 109 cases were analyzed: 54 women received intervention, and 55 women received placebo. Mean participant age was 52 years, and mean body mass index was 30.4 kg/m 2 . Surgical and

  18. EVALUATION OF SOLID SORBENTS AS A RETROFIT TECHNOLOGY FOR CO2 CAPTURE FROM COAL-FIRED POWER PLANTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holly Krutka; Sharon Sjostrom

    2011-07-31

    different field sites. ADA designed and fabricated a slipstream pilot to allow an evaluation of the kinetic behavior of sorbents and provide some flexibility for the physical characteristics of the materials. The design incorporated a transport reactor for the adsorber (co-current reactor) and a fluidized-bed in the regenerator. This combination achieved the sorbent characterization goals and provided an opportunity to evaluate whether the potential cost savings associated with a relatively simple process design could overcome the sacrifices inherent in a co-current separation process. The system was installed at two field sites during the project, Luminant's Martin Lake Steam Electric Station and Xcel Energy's Sherburne County Generating Station (Sherco). Although the system could not maintain continuous 90% CO{sub 2} removal with the sorbents evaluated under this program, it was useful to compare the CO{sub 2} removal properties of several different sorbents on actual flue gas. One of the supported amine materials, sorbent R, was evaluated at both Martin Lake and Sherco. The 1 kWe pilot was operated in continuous mode as well as batch mode. In continuous mode, the sorbent performance could not overcome the limitations of the cocurrent adsorbent design. In batch mode, sorbent R was able to remove up to 90% CO{sub 2} for several cycles. Approximately 50% of the total removal occurred in the first three feet of the adsorption reactor, which was a transport reactor. During continuous testing at Sherco, CO{sub 2} removal decreased to approximately 20% at steady state. The lack of continuous removal was due primarily to the combination of a co-current adsorption system with a fluidized bed for regeneration, a combination which did not provide an adequate driving force to maintain an acceptable working CO{sub 2} capacity. In addition, because sorbent R consisted of a polymeric amine coated on a silica substrate, it was believed that the 50% amine loaded resulted in mass

  19. Cell therapy of hip osteonecrosis with autologous bone marrow grafting.

    PubMed

    Hernigou, Philippe; Poignard, Alexandre; Zilber, Sebastien; Rouard, Hélène

    2009-01-01

    One of the reasons for bone remodeling leading to an insufficient creeping substitution after osteonecrosis in the femoral head may be the small number of progenitor cells in the proximal femur and the trochanteric region. Because of this lack of progenitor cells, treatment modalities should stimulate and guide bone remodeling to sufficient creeping substitution to preserve the integrity of the femoral head. Core decompression with bone graft is used frequently in the treatment of osteonecrosis of the femoral head. In the current series, grafting was done with autologous bone marrow obtained from the iliac crest of patients operated on for early stages of osteonecrosis of the hip before collapse with the hypothesis that before stage of subchondral collapse, increasing the number of progenitor cells in the proximal femur will stimulate bone remodeling and creeping substitution and thereby improve functional outcome. Between 1990 and 2000, 342 patients (534 hips) with avascular osteonecrosis at early stages (Stages I and II) were treated with core decompression and autologous bone marrow grafting obtained from the iliac crest of patients operated on for osteonecrosis of the hip. The percentage of hips affected by osteonecrosis in this series of 534 hips was 19% in patients taking corticosteroids, 28% in patients with excessive alcohol intake, and 31% in patients with sickle cell disease. The mean age of the patients at the time of decompression and autologous bone marrow grafting was 39 years (range: 16-61 years). The aspirated marrow was reduced in volume by concentration and injected into the femoral head after core decompression with a small trocar. To measure the number of progenitor cells transplanted, the fibroblast colony forming unit was used as an indicator of the stroma cell activity. Patients were followed up from 8 to 18 years. The outcome was determined by the changes in the Harris hip score, progression in radiographic stages, change in volume

  20. LAPAROSCOPICALLY ASSISTED ANORECTOPLASTY AND THE USE OF THE BIPOLAR DEVICE TO SEAL THE RECTAL URINARY FISTULA.

    PubMed

    Dutra, Robson Azevedo; Boscollo, Adriana Cartafina Perez

    2016-01-01

    The anorectal anomalies consist in a complex group of birth defects. Laparoscopic-assisted anorectoplasty improved visualization of the rectal fistula and the ability to place the pull-through segment within the elevator muscle complex with minimal dissection. There is no consensus on how the fistula should be managed. To evaluate the laparoscopic-assisted anorectoplasty and the treatment of the rectal urinary fistula by a bipolar sealing device. It was performed according to the original description by Georgeson1. Was used 10 mm infraumbilical access portal for 30º optics. The pneumoperitoneum was established with pressure 8-10 cm H2O. Two additional trocars of 5 mm were placed on the right and left of the umbilicus. The dissection started on peritoneal reflection using Ligasure(r). With the reduction in the diameter of the distal rectum was identified the fistula to the urinary tract. The location of the new anus was defined by the location of the external anal sphincter muscle complex, using electro muscle stimulator externally. Finally, it was made an anastomosis between the rectum and the new location of the anus. A Foley urethral probe was left for seven days. Seven males were operated, six with rectoprostatic and one with rectovesical fistula. The follow-up period ranged from one to four years. The last two patients operated underwent bipolar sealing of the fistula between the rectum and urethra without sutures or surgical ligation. No evidence of urethral leaks was identified. There are benefits of the laparoscopic-assisted anorectoplasty for the treatment of anorectal anomaly. The use of a bipolar energy source that seals the rectal urinary fistula has provided a significant decrease in the operating time and made the procedure be more elegant. As anomalias anorretais consistem de um grupo complexo de defeitos congênitos. A anorretoplastia laparoscópica permite melhor visualização da fístula retourinária e propicia o posicionamento do reto abaixado

  1. SIMPLIFIED LAPAROSCOPIC GASTRIC BYPASS WITH GASTROJEJUNAL LINEAR MECHANICAL ANASTOMOSIS: TECHNICAL ASPECTS.

    PubMed

    Palermo, Mariano; Serra, Edgardo

    Gastric bypass is a restrictive and malabsorptive surgery. The restrictive part consists in the creation of a small gastric pouch. The gastrointestinal bypass serves as the malabsorptive element. To describe a simplified gastric bypass approach for morbid obese patients, showing our results, and also remarking the importance of this technique for reducing the learning curve. The patient is positioned in a split legs position and carefully strapped to the operating room table, with the surgeon between the patient's legs. Five trocars are inserted after pneumoperitoneum at the umbilicus. Dissection of the esophagogastric angle and lesser curvature is mandatory before the gastric pouch manufacturing. This pouch is done with two blue load staplers. Using a blue load linear stapler inserted only half way into the hole in the pouch is used to perform the gastrojejunal anastomosis and in order to create an anastomosis that is about 2 cm in length. A side-to-side jejunojejunostomy is done with a white load linear stapler. The last step of the gastric bypass consists in the cut of the jejunum between the two anastomosis with a white load linear stapler. Blue test is performed in order to detect leaks. From January 2012 to December 2015, 415 simplified RYGB were performed. Gender: 67% female and 33 % males. Average of BMI 44.7. Mean age was 42 years old. Mean operative time 79 min. 39 % of this sample had T2 diabetes. Regarding complications were observed, one fistula, one gastrojejunal stenosis and one obstruction due to a bezoar. The described technique is a simplified approach in which all the anastomosis are performed in the upper part of the abdomen, allowing the surgeons to be more systematized and avoiding them to make mistakes in the confection of the Roux-en-Y anastomosis. This simplified gastric bypass is a safe and reproducible technique. Bypass gástrico é cirurgia restritiva e malabsortiva. A parte restritiva consiste na criação de uma pequena bolsa g

  2. Midurethral Slings for Women with Stress Urinary Incontinence

    PubMed Central

    2006-01-01

    women with stress urinary incontinence may not tell their health practitioner about their symptoms due to embarrassment associated with stress urinary incontinence. A cross-sectional postal survey of 15,904 adults aged 40 and over who were registered with a local GP in Leicestershire, United Kingdom, revealed that 18% to 34% of respondents had symptoms of SUI. (5) Just over 9% reported symptoms “sometimes,” while almost 3% reported symptoms “most of the time.” Stress urinary incontinence was most common for women in their 50s. A more recent study suggests that 24% of women aged 18 to 44 years and 37% of women aged 45 and over have symptoms of stress urinary incontinence. (6) Stress urinary incontinence has been associated with a broad range of psychosocial stress and disablement, such as difficulties with activities of daily living, avoidance of social activities, fear of unpleasant odour, and embarrassment. (7) Economic burden may include the cost of pads, drugs, and devices, and the inability to participate in the work force in severe cases. Midurethral Slings Suburethral slings differ according to several criteria including placement, approach, method of fixation, and sling material. This review will evaluate slings which fulfill all of the following criteria: Midurethral placement (as opposed to bladder neck placement) Self-fixing (no sutures, bone anchors, etc.) Minimally invasive (using local, epidural, or general anesthesia) “Tension-free” placement The different types of midurethral slings available vary according to 3 main parameters: Implant material, i.e., monofilament, multifilament, elastic, non-elastic, smooth, serrated, etc., Delivery instruments, i.e., needles, curved trocars, disposable, reusable, etc., Surgical approach As any one, or any combination of these parameters may vary across the different sling brands, it is difficult to ascribe observed differences in efficacy and safety across slings to any one factor. Review Strategy The

  3. Evaluation of Solid Sorbents As A Retrofit Technology for CO{sub 2} Capture from Coal-Fired Power Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krutka, Holly; Sjostrom, Sharon

    2011-07-31

    different field sites. ADA designed and fabricated a slipstream pilot to allow an evaluation of the kinetic behavior of sorbents and provide some flexibility for the physical characteristics of the materials. The design incorporated a transport reactor for the adsorber (co-current reactor) and a fluidized-bed in the regenerator. This combination achieved the sorbent characterization goals and provided an opportunity to evaluate whether the potential cost savings associated with a relatively simple process design could overcome the sacrifices inherent in a co-current separation process. The system was installed at two field sites during the project, Luminant’s Martin Lake Steam Electric Station and Xcel Energy’s Sherburne County Generating Station (Sherco). Although the system could not maintain continuous 90% CO{sub 2} removal with the sorbents evaluated under this program, it was useful to compare the CO{sub 2} removal properties of several different sorbents on actual flue gas. One of the supported amine materials, sorbent R, was evaluated at both Martin Lake and Sherco. The 1 kWe pilot was operated in continuous mode as well as batch mode. In continuous mode, the sorbent performance could not overcome the limitations of the co-current adsorbent design. In batch mode, sorbent R was able to remove up to 90% CO{sub 2} for several cycles. Approximately 50% of the total removal occurred in the first three feet of the adsorption reactor, which was a transport reactor. During continuous testing at Sherco, CO{sub 2} removal decreased to approximately 20% at steady state. The lack of continuous removal was due primarily to the combination of a co-current adsorption system with a fluidized bed for regeneration, a combination which did not provide an adequate driving force to maintain an acceptable working CO{sub 2} capacity. In addition, because sorbent R consisted of a polymeric amine coated on a silica substrate, it was believed that the 50% amine loaded resulted in mass

  4. A Public-Private-Academic Partnership to Advance Solar Power Forecasting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marquis, Melinda; Benjamin, Stan; James, Eric

    . Ground Observations In the ground-based measurement effort, NOAA's main objectives are to provide high quality radiation products for validation and verification of short-term to day-ahead solar forecasts. More specifically for the three year project, our goals include (1) Maintaining and providing data from our 7 SURFRAD and 7 ISIS; (2) Update ISIS radiation measurements from 3 min to 1 min data: (3) Purchase and install new pyrheliometers for direct solar irradiance measurements at the 7 SURFRAD sites; (4) Building, testing, and deploying two mobile SURFRAD stations at two utility plants in collaboration with DOE sponsored partners, and includes ongoing maintenance and processing of the data at the mobile sites; (5) Upgrading the data acquisition and communications at 7 SURFRAD sites and 7 ISIS sites; (6) Providing radiation data at the 7 SURFRAD sites in near real-time; (7) Develop and provide aerosol optical depth and cloud images and cloud fraction at our two mobile sites; (8) Provide data recovery rates each year; (9) Provide temporally and spatially averaged radiation products for comparison to HRRR and RAP solar forecasts and advanced satellite products; (10) Provide a data-set for analysis of conversion of direct and diffuse to sloped surfaces; (11) and as time permits develop and provide spectral solar irradiance, cloud optical depth and spectral albedo from the mobile sites. Milestones this year include working with the DOE sponsored teams to find locations to deploy two mobile SURFRAD stations. One existing unit was deployed at a 30MW PV facility in the San Luis Valley in collaboration with Xcel and the NCAR team in August, 2014. The second unit was built and tested at our facilities in Boulder, CO and deployed near Green Mountain Power's Education Center in Rutland, VT in collaboration with Green Mountain Power and the IBM Team in October, 2014. Data processing was implemented and the radiation data from these two mobile sites have been made available on our