  1. Contribution of the xenograft bone plate-screw system in lumbar transpedicular stabilization: An in vivo study in dogs

    PubMed Central

    Sarigul, Sani; Salci, Hakan; Lekesiz, Huseyin; Dogan, Seref; Ozcan, Resat; Gorgul, Osman Sacit; Aksoy, Kaya

    2017-01-01

    Objectives: Xenograft bone plate-screws (XBPSs) can be alternative tools in lumbar transpedicular stabilization (TS). The aim of this study was to show biomechanical and histopathological contribution of the XBPSs system in lumbar TS. Materials and Methods: Fifteen (n = 15) hybrid dog and ten (n = 10) L2-4 cadaveric specimens were included in the study. The dogs were separated according to surgical techniques: L3 laminectomy and bilateral facetectomy (LBF) in Group I (experimental group [EG I] (n = 5), L3 LBF plus TS with metal plate-screws (MPSs) in Group II (EG II) (n = 5), and L3 LBF plus TS with XBPSs in Group III (EG III) (n = 5). The cadaveric specimens were separated to L2-4 intact in Group I (CG I), (n = 5), and L3 LBF in Group II (CG II), (n = 5). The dogs were sacrificed at the end of 3rd month, and their L2-4 spinal segments were en bloc removed and prepared as in control groups. Flexion, extension, left-right bending, rotation, and compression tests were applied to all segments. Stiffness values were calculated and analyzed statistically. All dog segments were evaluated histopathologically. Results: XBPS system showed a higher average stiffness values for left bending, extension, flexion, and compression compared to MPS, but these differences were not statistically meaningful. XBPS system had superiority to the fusion formation, as well. Conclusions: XBPSs provide stability and help the fusion formation, but this system does not have a biomechanical advantage over MPS system in TS. PMID:28761530

  2. Degradation behaviour of LAE442-based plate-screw-systems in an in vitro bone model.

    PubMed

    Wolters, Leonie; Besdo, Silke; Angrisani, Nina; Wriggers, Peter; Hering, Britta; Seitz, Jan-Marten; Reifenrath, Janin

    2015-04-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate-screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15cNm or 7cNm, NaOH treated plates (15cNm), magnesium fluoride coated plates (15cNm) and steel plates as control (15cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. [Fusion of reconstructed titanic plate, vertebral pedical screws and autogenous granulated cancellous bone graft in posterior occipitocervical region].

    PubMed

    Zhong, Dejun; Song, Yueming

    2006-08-01

    To explore the technique of fusing the reconstructed titanic plate, the C2 pedical screws, and the autogenous granulated cancellous bone graft in the occipitocervical region. From April 2002 to January 2005, 19 patients aged 31-67 years with occipitocervical instability underwent the occipitocervical fusion using the reconstructed plate, C2 pedical screws, and autogenous granulated cancellous bone graft. Of the patients, 8 had complex occipitocervical deformity, 8 had old atlantoaxial fracture and dislocation, 2 had rheumatoid arthritis and anterior dislocation of the atlantoaxial joint, and 1 had cancer of the deltoid process of the axis. No complication occurred during and after operation. The follow-up for an average of 16 months in 19 patients showed that all the patients achieved solid bony fusion in the occipitocervical region. There was no broken plate, broken screw, looseness of the internal fixation or neurovascular injury. The fixation of the C2 pedical screws with the reconstructed titanic plate is reliable, the insertion is easy, and the autogenous granulated cancellous bone graft has a high fusion rate, thus resulting in a satisfactory effect in the occipitocervical fusion.

  4. Screw Versus Plate Fixation for Chevron Osteotomy: A Retrospective Study.

    PubMed

    Andrews, Boyd J; Fallat, Lawrence M; Kish, John P

    2016-01-01

    The chevron osteotomy is a popular procedure used for the correction of moderate hallux abducto valgus deformity. Fixation is typically accomplished with Kirschner wires or bone screws; however, in cystic or osteoporotic bone, these could be inadequate, resulting in displacement of the capital fragment. We propose using a locking plate and interfragmental screw for fixation of the chevron osteotomy that could reduce the healing time and decrease the incidence of displacement. We performed a retrospective cohort study for chevron osteotomies on 75 feet (73 patients). The control groups underwent fixation with 1 screw in 30 feet (40%) and 2 screws in 30 feet (40%). A total of 15 feet (20%) were included in the locking plate and interfragmental screw group. The patients were followed up until bone healing was achieved at a median of 7 (range 6 to 14) weeks. Our hypothesis was that those treated with the locking plate and interfragmental screw would have a faster healing time and fewer incidents of capital fragment displacement compared with the 1- or 2-screw groups. The corresponding mean intervals to healing for the 1-screw group was 7.71 ± 1.28 (range 6 to 10) weeks, for the 2-screw group was 7.27 ± 1.57 (range 6 to 14) weeks, and for the locking plate and interfragmental screw group was 7.01 ± 1.00 (range 6 to 9) weeks. One case of capital fragment displacement occurred in the single screw group and one in the 2-screw group. No displacement occurred in the locking plate and interfragmental screw group. Neither finding was statistically significant. However, we believe the locking plate and interfragmental screw could be a viable option in patients with osteoporotic and cystic bone changes for correction of hallux abducto valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Enhanced bone screw fixation with biodegradable bone cement in osteoporotic bone model.

    PubMed

    Juvonen, Tiina; Koistinen, Arto; Kröger, Heikki; Lappalainen, Reijo

    2012-09-27

    The purpose of this study was to study the potential of novel biodegradable PCL bone cement to improve bone screw fixation strength in osteoporotic bone. The biomechanical properties of bone cement (ε-polycaprolactone, PCL) and fixation strength were studied using biomechanical tests and bone screws fixed in an osteoporotic bone model. Removal torques and pullout strengths were assessed for cortical, self-tapping, and cancellous screws inserted in the osteoporotic bone model (polyurethane foam blocks with polycarbonate plate) with and without PCL bone cement. Open cell and cellular rigid foam blocks with a density of 0.12 g/cm3 were used in this model. Removal torques were significantly (more than six-fold) improved with bone cement for cancellous screws. Furthermore, the bone cement improved pullout strengths three to 12 times over depending on the screw and model material. Biodegradable bone cement turned out to be a very potential material to stabilize screw fixation in osteoporotic bone. The results warrant further research before safe clinical use, especially to clarify clinically relevant factors using real osteoporotic bone under human body conditions and dynamic fatigue testing for long-term performance.

  6. Anterior cervical plate fixation with the titanium hollow screw plate system. A preliminary report.

    PubMed

    Suh, P B; Kostuik, J P; Esses, S I

    1990-10-01

    Morscher, of Switzerland, has developed an anterior cervical spine plate system (THSP) that does not require screw purchase of the posterior cortex. This design eliminates potential neurologic complications usually associated with the anterior plate system, but maintains the mechanical advantages of internal fixation. The authors reviewed 13 consecutive patients in whom the THSP system was applied. Indications for the use of this device included acute trauma in three patients, trauma of more than 6 weeks' duration in five patients, and spondylosis in five patients. Fifteen plates and 58 screws were placed, with no screws purchasing the posterior cortex. Postoperative immobilization varied from no immobilization to four-poster brace. With a mean follow-up of 13 months, all 13 patients went on to fusion. One patient had screws placed in the disc rather than in bone and went on to malunion. In all other patients, radiographs did not demonstrate screw migration, screw-bone lucency, graft dislodgement, or malunion. No patient suffered neurologic injury as a result of this device. The THSP system facilitates reliable fusion with minimal complications. Its use should be considered in multilevel anterior spine defects, posttraumatic cervical kyphosis, and cervical fractures with posterior disruption requiring anterior fusion.

  7. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    PubMed

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  8. Osteosynthesis of partial rib osteotomy in a miniature pig model using human standard-sized magnesium plate/screw systems: Effect of cyclic deformation on implant integrity and bone healing.

    PubMed

    Schaller, Benoit; Saulacic, Nikola; Beck, Stefan; Imwinkelried, Thomas; Liu, Edwin Wei Yang; Nakahara, Ken; Hofstetter, Willy; Iizuka, Tateyuki

    2017-06-01

    Magnesium alloys are candidates for resorbable material in bone fixation. However, the degradation and performance of osteosynthesis plate/screw systems in vivo, under cyclic deformation, is unknown. We evaluated the outcomes of human standard-sized magnesium plate/screw systems with or without plasma-electrolytic surface modifications in a miniature pig rib model. Of a total of 14 minipigs, six were implanted with coated magnesium WE43 six-hole plates/screws, six received magnesium uncoated plates/screws, and two received titanium osteosynthesis systems. The performance of the plate/screw fixation system on partially osteotomized 7th ribs was compared with that on intact 9th ribs. Radiological examinations were performed in vivo at 1, 4 and 8 weeks and after euthanasia at 12 and 24 weeks. After euthanasia the bone blocks were analyzed by computed tomography (CT), microfocus computed tomography (micro-CT), histology and histomorphometry. Follow-up post-surgery showed no trouble with wound healing. In vivo radiological examinations showed higher amounts of gas formation above the uncoated magnesium plates fixed on the partially osteotomized and intact ribs. CT scans showed no broken plates or implant displacement. The micro-CT examination demonstrated better surrounding bone properties around the coated than the uncoated magnesium implants 12 weeks after surgery. No negative influence of magnesium degradation on bone healing was observed with histological examinations. Plastic deformation during surgery and cyclic deformation did not affect the integrity of the used magnesium plates. This study showed promising results for the further development of coated magnesium plate/screw systems for bone fixation. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Screw fixation versus arthroplasty versus plate fixation for 3-part radial head fractures.

    PubMed

    Wu, P H; Shen, L; Chee, Y H

    2016-04-01

    To compare the outcome following headless compression screw fixation versus radial head arthroplasty versus plate fixation for 3-part Mason types III or IV radial head fracture. Records of 25 men and 16 women aged 21 to 80 (mean, 43.3) years who underwent fixation using 2 to 3 2-mm cannulated headless compression screws (n=16), radial head arthroplasty (n=13), or fixation with a 2-mm Synthes plate (n=12) for 3-part Mason types III or IV radial head and neck fracture were reviewed. Treatment option was decided by the surgeon based on the presence of associated injury, neurovascular deficit, and the Mason classification. Bone union, callus formation, and complications (such as heterotopic ossification, malunion, and nonunion) were assessed by an independent registrar or consultant using radiographs. The Mayo Elbow Performance Score and range of motion were assessed by an independent physiotherapist. The median age of the 3 groups were comparable. Associated injuries were most common in patients with arthroplasty, followed by screw fixation and plate fixation (61.5% vs. 50% vs. 33%, p=0.54). The median time to bone union was shorter after screw fixation than plate fixation (55 vs. 86 days, p=0.05). No patient with screw fixation had nonunion, but 4 patients with plate fixation had nonunion. The 3 groups were comparable in terms of the mean Mayo Elbow Performance Score (p=0.56) and the mean range of motion (p=0.45). The complication rate was highest after plate fixation, followed by screw fixation and arthroplasty (50% vs. 18.8% vs. 15.4%, p=0.048). Excluding 20 patients with associated injuries (8 in screw fixation, 8 in arthroplasty, and 4 in plate fixation), the 3 groups were comparable in terms of the median time to bone union (p=0.109), mean Mayo Elbow Performance Score (p=0.260), mean range of motion (p=0.162), and complication rate (p=0.096). Headless compression screw fixation is a viable option for 3-part radial head fracture. It achieves earlier bone union

  10. Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

    PubMed

    Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark

    2015-04-01

    The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p < 0.01) and a significantly lower axial migration over cycles compared with LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p < 0.01) and a significantly higher relative movement (1.1 mm, SD 0.05, p < 0.01) compared with LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.

  11. The Effect of Polymethyl Methacrylate Augmentation on the Primary Stability of Cannulated Bone Screws in an Anterolateral Plate in Osteoporotic Vertebrae: A Human Cadaver Study.

    PubMed

    Rüger, Matthias; Sellei, Richard M; Stoffel, Marcus; von Rüden, Christian

    2016-02-01

    Study Design Cohort study. Objective Expandable anterolateral plates facilitate the reduction of posttraumatic deformities of thoracolumbar spine injuries and are commonly used in cases of unstable injuries or compromised bone quality. In this in vitro study, the craniocaudal yield load of the osseous fixation of an anterior angular stable plate fixation system and the effect of polymethyl methacrylate (PMMA) screw augmentation on the primary stability of the screw-bone interface during kyphosis reduction was evaluated in 12 osteoporotic human thoracolumbar vertebrae. Methods The anterolateral stabilization device used for this study is comprised of two swiveling flanges and an expandable midsection. It facilitates the controlled reduction of kyphotic deformities in situ with a geared distractor. Single flanges were attached to 12 thoracolumbar vertebrae. Six specimens were augmented with PMMA by means of cannulated bone screws. The constructs were subjected to static, displacement-controlled craniocaudal loading to failure in a servohydraulic testing machine. Results The uncemented screws cut out at a mean 393 ± 66 N, whereas the cemented screws showed significantly higher yield load of 966 ± 166 N (p < 0.02). We detected no significant correlation between bone mineral density and yield load in this setting. Conclusion Our results indicate that PMMA augmentation is an effective method to increase two- to threefold the primary stability of the screw-bone interface of an anterolateral spine stabilization system in osteoporotic bone. We recommend it in cases of severely compromised bone quality to reduce the risk of screw loosening during initial kyphosis correction and to increase long-term construct stability.

  12. Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration.

    PubMed

    Carrera, Ion; Gelber, Pablo Eduardo; Chary, Gaetan; González-Ballester, Miguel A; Monllau, Juan Carlos; Noailly, Jerome

    2016-10-01

    To assess, with finite element (FE) calculations, whether immediate weight bearing would be possible after surgical stabilization either with cannulated screws or with a locking plate in a split fracture of the lateral tibial plateau (LTP). A split fracture of the LTP was recreated in a FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. A split fracture of the lateral tibial plateau was reproduced by using geometrical data from patient radiographs. A locking screw plate (LP) and a cannulated screw (CS) systems were modelled to virtually reduce the fracture and 80 kg static body-weight was simulated. While the simulated body-weight led to clinically acceptable interfragmentary motion, possible traumatic bone shear stresses were predicted nearby the cannulated screws. With a maximum estimation of about 1.7 MPa maximum bone shear stresses, the Polyax system might ensure more reasonable safety margins. Split fractures of the LTP fixed either with locking screw plate or cannulated screws showed no clinically relevant IFM in a FE model. The locking screw plate showed higher mechanical stability than cannulated screw fixation. The locking screw plate might also allow full or at least partial weight bearing under static posture at time zero.

  13. Use of resorbable plates and screws in pediatric facial fractures.

    PubMed

    Eppley, Barry L

    2005-03-01

    The use of resorbable plates and screws for fixation of pediatric facial fractures is both well tolerated and effective. It enables realignment and stable positioning of rapidly healing fracture segments while obviating any future issues secondary to long-term metal retention. Forty-four pediatric facial fractures were treated over a 10-year period at our institution using differing techniques of polymeric bone fixation. Twenty-nine mandible fractures in patients under the age of 10 (age range, 6 months to 8 years) were treated. Displaced fractures of the symphysis, parasymphysis, body, and ramus underwent open reduction and either 1.5-mm or 2.0-mm plate and screw fixation in 14 patients. Subcondylar fractures were treated by a short period of maxillomandibular fixation (3 weeks) achieved with suture ligation between resorbable screws placed at the zygoma and symphysis or a circummandibular suture attached to a zygomatic screw. Fifteen patients (age range, 4 to 11 years) with isolated frontal, supraorbital, intraorbital, or orbitozygomatic fractures were treated by open reduction and internal fixation with 1.5-mm resorbable plates, mesh, and screws. No long-term implant-related complications were seen in any of the treated patients. Resorbable polylactic and polyglycolic acid plates and screws can be an effective fixation method for facial fractures in children in the primary and secondary dentition periods.

  14. Scanning electron microscopic observations of 'fractured' biodegradable plates and screws.

    PubMed

    Kosaka, Masaaki; Uemura, Fumiko; Tomemori, Shoko; Kamiishi, Hiroshi

    2003-02-01

    We encountered two out of 100 cases in which implanted biodegradable plates and screws had fractured within 1 month postoperatively. Failure of the material was confirmed through clinical symptoms, radiographs or CT findings. In addition, four specimens obtained from these two cases were examined with regard to their ultrastructure using scanning electron microscopy. Several principal patterns of the fractured surface were found: (1) gradual cracking, i.e. 'circular stair' and, (2) tortuous threads, i.e. a wavy line. It is conceivable that the material may not have been hit by major sudden forces but a disproportion between the thread configuration and the drilled hole may have led to screw loosening and torsion. Subsequently, the threads were deformed in a 'wavy' manner, finally leading to cracking and fracture of plates and screws. Fractures of plates and screws due to these instabilities are thought to be distinguishable from material resorption. In the application of biodegradable materials, more than two screws per single bone segment should be used as a principle of plate-fixation technique in order to avoid a stability-compromising situation, particularly in the stress-bearing areas of the maxillofacial region. Moreover, three-dimensional fixation using more than two plates is recommended in the facial skeleton e.g. zygomatic tripod. Intermaxillary fixation should also be considered to reinforce initial stability in stress-bearing areas.

  15. [Osteostimulating effect of bone xenograft on bone tissue regeneration].

    PubMed

    Balin, V N; Balin, D V; Iordanishvili, A K; Musikin, M I

    2015-01-01

    The aim of experimental case-control study performed in 28 dogs divided in 2 groups was to assess local tissue reactions on bone xenograft transplantation; dynamics of bone remodeling and formation at the site of bone defect wall contacting with bone xenograft; dynamics and mechanisms of xenograft remodeling. Transplantation of xenograft in conventional bone defects did not cause inflammatory of destructive reactions because of high biocompatibility of the material. At transplantation site active fibrous bone trabeculae formation filling the spaces between xenograft participles was observed. On the 90th day newly formed bone showed lammelar structure. Simultaneously from the 42d day the invasion of cell elements from recipient bed into the material was seen leading to xenograft resorption. The observed dynamics may be assessed as gradual substitution of xenograft with newly formed host bone structures.

  16. The Effect of Polymethyl Methacrylate Augmentation on the Primary Stability of Cannulated Bone Screws in an Anterolateral Plate in Osteoporotic Vertebrae: A Human Cadaver Study

    PubMed Central

    Rüger, Matthias; Sellei, Richard M.; Stoffel, Marcus; von Rüden, Christian

    2015-01-01

    Study Design Cohort study. Objective Expandable anterolateral plates facilitate the reduction of posttraumatic deformities of thoracolumbar spine injuries and are commonly used in cases of unstable injuries or compromised bone quality. In this in vitro study, the craniocaudal yield load of the osseous fixation of an anterior angular stable plate fixation system and the effect of polymethyl methacrylate (PMMA) screw augmentation on the primary stability of the screw–bone interface during kyphosis reduction was evaluated in 12 osteoporotic human thoracolumbar vertebrae. Methods The anterolateral stabilization device used for this study is comprised of two swiveling flanges and an expandable midsection. It facilitates the controlled reduction of kyphotic deformities in situ with a geared distractor. Single flanges were attached to 12 thoracolumbar vertebrae. Six specimens were augmented with PMMA by means of cannulated bone screws. The constructs were subjected to static, displacement-controlled craniocaudal loading to failure in a servohydraulic testing machine. Results The uncemented screws cut out at a mean 393 ± 66 N, whereas the cemented screws showed significantly higher yield load of 966 ± 166 N (p < 0.02). We detected no significant correlation between bone mineral density and yield load in this setting. Conclusion Our results indicate that PMMA augmentation is an effective method to increase two- to threefold the primary stability of the screw–bone interface of an anterolateral spine stabilization system in osteoporotic bone. We recommend it in cases of severely compromised bone quality to reduce the risk of screw loosening during initial kyphosis correction and to increase long-term construct stability. PMID:26835201

  17. Dorsal bridge plating or transarticular screws for Lisfranc fracture dislocations.

    PubMed

    Kirzner, N; Zotov, P; Goldbloom, D; Curry, H; Bedi, H

    2018-04-01

    Aims The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations. Patients and Methods A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction. Results Significantly better functional outcomes were seen in the bridge plate group. These patients had a mean AOFAS score of 82.5 points, compared with 71.0 for the screw group and 63.3 for the combination group (p < 0.001). Similarly, the mean Manchester Oxford Foot Questionnaire score was 25.6 points in the bridge plate group, 38.1 in the screw group, and 45.5 in the combination group (p < 0.001). Functional outcome was dependent on the quality of reduction (p < 0.001). A trend was noted which indicated that plate fixation is associated with a better anatomical reduction (p = 0.06). Myerson types A and C2 significantly predicted a poorer functional outcome, suggesting that total incongruity in either a homolateral or divergent pattern leads to worse outcomes. The greater the number of columns fixed the worse the outcome (p < 0.001). Conclusion Patients treated with dorsal bridge plating have better functional and radiological outcomes than those treated with transarticular screws or a combination technique. Cite this article: Bone Joint J 2018;100-B:468-74.

  18. Finite Element Analysis of Osteosynthesis Screw Fixation in the Bone Stock: An Appropriate Method for Automatic Screw Modelling

    PubMed Central

    Wieding, Jan; Souffrant, Robert; Fritsche, Andreas; Mittelmeier, Wolfram; Bader, Rainer

    2012-01-01

    The use of finite element analysis (FEA) has grown to a more and more important method in the field of biomedical engineering and biomechanics. Although increased computational performance allows new ways to generate more complex biomechanical models, in the area of orthopaedic surgery, solid modelling of screws and drill holes represent a limitation of their use for individual cases and an increase of computational costs. To cope with these requirements, different methods for numerical screw modelling have therefore been investigated to improve its application diversity. Exemplarily, fixation was performed for stabilization of a large segmental femoral bone defect by an osteosynthesis plate. Three different numerical modelling techniques for implant fixation were used in this study, i.e. without screw modelling, screws as solid elements as well as screws as structural elements. The latter one offers the possibility to implement automatically generated screws with variable geometry on arbitrary FE models. Structural screws were parametrically generated by a Python script for the automatic generation in the FE-software Abaqus/CAE on both a tetrahedral and a hexahedral meshed femur. Accuracy of the FE models was confirmed by experimental testing using a composite femur with a segmental defect and an identical osteosynthesis plate for primary stabilisation with titanium screws. Both deflection of the femoral head and the gap alteration were measured with an optical measuring system with an accuracy of approximately 3 µm. For both screw modelling techniques a sufficient correlation of approximately 95% between numerical and experimental analysis was found. Furthermore, using structural elements for screw modelling the computational time could be reduced by 85% using hexahedral elements instead of tetrahedral elements for femur meshing. The automatically generated screw modelling offers a realistic simulation of the osteosynthesis fixation with screws in the adjacent

  19. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.

    PubMed

    Kosmopoulos, Victor; Luedke, Colten; Nana, Arvind D

    2015-01-01

    A smaller humerus in some patients makes the use of a large fragment fixation plate difficult. Dual small fragment plate constructs have been suggested as an alternative. This study compares the biomechanical performance of three single and one dual plate construct for mid-diaphyseal humeral fracture fixation. Five humeral shaft finite element models (1 intact and 4 fixation) were loaded in torsion, compression, posterior-anterior (PA) bending, and lateral-medial (LM) bending. A comminuted fracture was simulated by a 1-cm gap. Fracture fixation was modelled by: (A) 4.5-mm 9-hole large fragment plate (wide), (B) 4.5-mm 9-hole large fragment plate (narrow), (C) 3.5-mm 9-hole small fragment plate, and (D) one 3.5-mm 9-hole small fragment plate and one 3.5-mm 7-hole small fragment plate. Model A showed the best outcomes in torsion and PA bending, whereas Model D outperformed the others in compression and LM bending. Stress concentrations were located near and around the unused screw holes for each of the single plate models and at the neck of the screws just below the plates for all the models studied. Other than in PA bending, Model D showed the best overall screw-to-screw load sharing characteristics. The results support using a dual small fragment locking plate construct as an alternative in cases where crutch weight-bearing (compression) tolerance may be important and where anatomy limits the size of the humerus bone segment available for large fragment plate fixation.

  20. Are allogenic or xenogenic screws and plates a reasonable alternative to alloplastic material for osteosynthesis--a histomorphological analysis in a dynamic system.

    PubMed

    Jacobsen, C; Obwegeser, J A

    2010-12-01

    Despite invention of titanium and resorbable screws and plates, still, one of the main challenges in bone fixation is the search for an ideal osteosynthetic material. Biomechanical properties, biocompatibility, and also cost effectiveness and clinical practicability are factors for the selection of a particular material. A promising alternative seems to be screws and plates made of bone. Recently, xenogenic bone pins and screws have been invented for use in joint surgery. In this study, screws made of allogenic sheep and xenogenic human bone were analyzed in a vital and dynamic sheep-model and compared to conventional titanium screws over a standard period of bone healing of 56 days with a constant applied extrusion force. Biomechanical analysis and histomorphological evaluation were performed. After 56 days of insertion xenogenic screws made of human bone showed significantly larger distance of extrusion of on average 173.8 μm compared to allogenic screws made of sheep bone of on average 27.8 and 29.95 μm of the titanium control group. Severe resorption processes with connective tissue interposition were found in the histomorphological analysis of the xenogenic screws in contrast to new bone formation and centripetal vascularization of the allogenic bone screw, as well as in processes of incorporation of the titanium control group. The study showed allogenic cortical bone screws as a substantial alternative to titanium screws with good biomechanical properties. In contrast to other reports a different result was shown for the xenogenic bone screws. They showed insufficient holding strength with confirmative histomorphological signs of degradation and insufficient osseointegration. Before common clinical use of xenogenic osteosynthetic material, further evaluation should be performed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. Resorbable poly(D,L)lactide plates and screws for osteosynthesis of condylar neck fractures in sheep.

    PubMed

    Rasse, Michael; Moser, Doris; Zahl, Christian; Gerlach, Klaus Louis; Eckelt, Uwe; Loukota, Richard

    2007-01-01

    We made osteotomies in the condylar neck in 12 adult sheep to simulate fractures, and joined the two ends with 2 poly(D,L)lactide (PDLLA) plates and 8 PDLLA screws 2mm in diameter. The animals were killed after 2, 6, and 12 months and bony healing was assessed macroscopically and histologically. The plates and screws remained intact and there was no displacement of the bony ends. The degrading plates, which were still visible in the specimens after 6 months, had been replaced by bone. At 12 months the PDLLA had been resorbed with no foreign body reaction and no resorption of underlying bone. The articular discs showed no signs of degeneration.

  2. Effect of Off-Axis Screw Insertion, Insertion Torque, and Plate Contouring on Locked Screw Strength

    PubMed Central

    Gallagher, Bethany; Silva, Matthew J.; Ricci, William M.

    2015-01-01

    Objectives This study quantifies the effects of insertion torque, off-axis screw angulation, and plate contouring on the strength of locking plate constructs. Methods Groups of locking screws (n = 6–11 screws) were inserted at 50%, 100%, 150%, and 200% of the manufacturer-recommended torque (3.2 Nm) into locking compression plates at various angles: orthogonal (control), 5-degree angle off-axis, and 10-degree angle off-axis. Screws were loaded to failure by a transverse force (parallel to the plate) either in the same (“+”) or opposite direction (“−”) of the initial screw angulation. Separately, locking plates were bent to 5 and 10-degree angles, with the bend apex at a screw hole. Locking screws inserted orthogonally into the apex hole at 100% torque were loaded to failure. Results Orthogonal insertion resulted in the highest average load to failure, 2577 ± 141 N (range, 2413–2778 N), whereas any off-axis insertion significantly weakened constructs (165–1285 N, at 100% torque) (P < 0.05). For “+” loading, torque beyond 100% did not increase strength, but 50% torque reduced screw strength (P < 0.05). Loading in the “−” direction consistently resulted in higher strengths than “+” loading (P < 0.05). Plate contouring of 5-degree angle did not significantly change screw strength compared with straight plates but contouring of 10-degree angle significantly reduced load to failure (P < 0.05). Conclusions To maximize the screw plate interface strength, locking screws should be inserted without cross-threading. The mechanical stability of locked screws is significantly compromised by loose insertion, off-axis insertion, or severe distortion of the locking mechanism. PMID:24343255

  3. Predicting cancellous bone failure during screw insertion.

    PubMed

    Reynolds, Karen J; Cleek, Tammy M; Mohtar, Aaron A; Hearn, Trevor C

    2013-04-05

    Internal fixation of fractures often requires the tightening of bone screws to stabilise fragments. Inadequate application of torque can leave the fracture unstable, while over-tightening results in the stripping of the thread and loss of fixation. The optimal amount of screw torque is specific to each application and in practice is difficult to attain due to the wide variability in bone properties including bone density. The aim of the research presented in this paper is to investigate the relationships between motor torque and screw compression during powered screw insertion, and to evaluate whether the torque during insertion can be used to predict the ultimate failure torque of the bone. A custom test rig was designed and built for bone screw experiments. By inserting cancellous bone screws into synthetic, ovine and human bone specimens, it was established that variations related to bone density could be automatically detected through the effects of the bone on the rotational characteristics of the screw. The torque measured during screw insertion was found to be directly related to bone density and can be used, on its own, as a good predictor of ultimate failure torque of the bone. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  4. Effect of screw position on single cycle to failure in bending and torsion of a locking plate-rod construct in a synthetic feline femoral gap model.

    PubMed

    Niederhäuser, Simone K; Tepic, Slobodan; Weber, Urs T

    2015-05-01

    To evaluate the effect of screw position on strength and stiffness of a combination locking plate-rod construct in a synthetic feline femoral gap model. 30 synthetic long-bone models derived from beechwood and balsa wood. 3 constructs (2 locking plate-rod constructs and 1 locking plate construct; 10 specimens/construct) were tested in a diaphyseal bridge plating configuration by use of 4-point bending and torsion. Variables included screw position (near the fracture gap and far from the fracture gap) and application of an intramedullary pin. Constructs were tested to failure in each loading mode to determine strength and stiffness. Failure was defined as plastic deformation of the plate or breakage of the bone model or plate. Strength, yield angle, and stiffness were compared by use of a Wilcoxon test. Placement of screws near the fracture gap did not increase bending or torsional stiffness in the locking plate-rod constructs, assuming the plate was placed on the tension side of the bone. Addition of an intramedullary pin resulted in a significant increase in bending strength of the construct. Screw positioning did not have a significant effect on any torsion variables. Results of this study suggested that, in the investigated plate-rod construct, screw insertion adjacent to the fracture lacked mechanical advantages over screw insertion at the plate ends. For surgeons attempting to minimize soft tissue dissection, the decision to make additional incisions for screw placement should be considered with even more caution.

  5. A comparison of screw insertion torque and pullout strength.

    PubMed

    Ricci, William M; Tornetta, Paul; Petteys, Timothy; Gerlach, Darin; Cartner, Jacob; Walker, Zakiyyah; Russell, Thomas A

    2010-06-01

    Pullout strength of screws is a parameter used to evaluate plate screw fixation strength. However, screw fixation strength may be more closely related to its ability to generate sufficient insertion because stable nonlocked plate-screw fracture fixation requires sufficient compression between plate and bone such that no motion occurs between the plate and bone under physiological loads. Compression is generated by tightening of screws. In osteoporotic cancellous bone, sufficient screw insertion torque may not be generated before screw stripping. The effect of screw thread pitch on generation of maximum insertion torque (MIT) and pullout strength (POS) was investigated in an osteoporotic cancellous bone model and the relationship between MIT and POS was analyzed. Stainless steel screws with constant major (5.0 mm) and minor (2.7 mm) diameters but with varying thread pitches (1, 1.2, 1.5, 1.6, and 1.75 mm) were tested for MIT and POS in a validated osteoporotic surrogate for cancellous bone (density of 160 kg/m(3) [10 lbs/ft(3)]). MIT was measured with a torque-measuring hex driver for screws inserted through a one-third tubular plate. POS was measured after insertion of screws to a depth of 20 mm based on the Standard Specification and Test Methods for Metallic Medical Bone Screws (ASTM F 543-07). Five screws were tested for each failure mode and screw design. The relationship between MIT and compressive force between the plate and bone surrogate was evaluated using pressure-sensitive film. There was a significant difference in mean MIT based on screw pitch (P < 0.0001), whereas POS did not show statistically significant differences among the different screw pitches (P = 0.052). Small screw pitches (1.0 mm and 1.2 mm) had lower MIT and were distinguished from large pitches (1.5 mm, 1.6 mm, and the 1.75 mm) with higher MIT. For POS, only the 1-mm and 1.6-mm pitch screws were found to be different from each other. Linear regression analysis of MIT revealed a moderate

  6. Biomechanical evaluation of bone screw fixation with a novel bone cement.

    PubMed

    Juvonen, Tiina; Nuutinen, Juha-Pekka; Koistinen, Arto P; Kröger, Heikki; Lappalainen, Reijo

    2015-07-30

    Bone cement augmentation is commonly used to improve the fixation stability of orthopaedic implants in osteoporotic bone. The aim of this study was to evaluate the effect of novel bone cements on the stability of bone screw fixation by biomechanical testing and to compare them with a conventional Simplex(®)P bone cement and requirements of the standards. Basic biomechanical properties were compared with standard tests. Adhesion of bone cements were tested with polished, glass blasted and corundum blasted stainless steel surfaces. Screw pullout testing with/without cement was carried out using a synthetic bone model and cancellous and cortical bone screws. All the tested bone cements fulfilled the requirements of the standard for biomechanical properties and improved the screw fixation stability. Even a threefold increase in shear and tensile strength was achieved with increasing surface roughness. The augmentation improved the screw pullout force compared to fixation without augmentation, 1.2-5.7 times depending on the cement and the screw type. The good biomechanical properties of novel bone cement for osteoporotic bone were confirmed by experimental testing. Medium viscosity of the bone cements allowed easy handling and well-controlled penetration of bone cement into osteoporotic bone. By proper parameters and procedures it is possible to achieve biomechanically stable fixation in osteoporotic bone. Based on this study, novel biostable bone cements are very potential biomaterials to enhance bone screw fixation in osteoporotic bone. Novel bone cement is easy to use without hand mixing using a dual syringe and thus makes it possibility to use it as required during the operation.

  7. Polyaxial Screws in Locked Plating of Tibial Pilon Fractures.

    PubMed

    Yenna, Zachary C; Bhadra, Arup K; Ojike, Nwakile I; Burden, Robert L; Voor, Michael J; Roberts, Craig S

    2015-08-01

    This study examined the axial and torsional stiffness of polyaxial locked plating techniques compared with fixed-angle locked plating techniques in a distal tibia pilon fracture model. The effect of using a polyaxial screw to cross the fracture site was examined to determine its ability to control relative fracture site motion. A laboratory experiment was performed to investigate the biomechanical stiffness of distal tibia fracture models repaired with 3.5-mm anterior polyaxial distal tibial plates and locking screws. Sawbones Fourth Generation Composite Tibia models (Pacific Research Laboratories, Inc, Vashon, Washington) were used to model an Orthopaedic Trauma Association 43-A1.3 distal tibia pilon fracture. The polyaxial plates were inserted with 2 central locking screws at a position perpendicular to the cortical surface of the tibia and tested for load as a function of axial displacement and torque as a function of angular displacement. The 2 screws were withdrawn and inserted at an angle 15° from perpendicular, allowing them to span the fracture and insert into the opposing fracture surface. Each tibia was tested again for axial and torsional stiffness. In medial and posterior loading, no statistically significant difference was found between tibiae plated with the polyaxial plate and the central screws placed in the neutral position compared with the central screws placed at a 15° position. In torsional loading, a statistically significant difference was noted, showing greater stiffness in tibiae plated with the polyaxial plate and the central screws placed at a 15° position compared with tibiae plated with the central screws placed at a 0° (or perpendicular) position. This study showed that variable angle constructs show similar stiffness properties between perpendicular and 15° angle insertions in axial loading. The 15° angle construct shows greater stiffness in torsional loading. Copyright 2015, SLACK Incorporated.

  8. In vivo study of magnesium plate and screw degradation and bone fracture healing.

    PubMed

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Myers, Nicole; Costello, Bernard J; Chou, Da-Tren; Pal, Siladitya; Maiti, Spandan; Kumta, Prashant N; Sfeir, Charles

    2015-05-01

    Each year, millions of Americans suffer bone fractures, often requiring internal fixation. Current devices, like plates and screws, are made with permanent metals or resorbable polymers. Permanent metals provide strength and biocompatibility, but cause long-term complications and may require removal. Resorbable polymers reduce long-term complications, but are unsuitable for many load-bearing applications. To mitigate complications, degradable magnesium (Mg) alloys are being developed for craniofacial and orthopedic applications. Their combination of strength and degradation make them ideal for bone fixation. Previously, we conducted a pilot study comparing Mg and titanium devices with a rabbit ulna fracture model. We observed Mg device degradation, with uninhibited healing. Interestingly, we observed bone formation around degrading Mg, but not titanium, devices. These results highlighted the potential for these fixation devices. To better assess their efficacy, we conducted a more thorough study assessing 99.9% Mg devices in a similar rabbit ulna fracture model. Device degradation, fracture healing, and bone formation were evaluated using microcomputed tomography, histology and biomechanical tests. We observed device degradation throughout, and calculated a corrosion rate of 0.40±0.04mm/year after 8 weeks. In addition, we observed fracture healing by 8 weeks, and maturation after 16 weeks. In accordance with our pilot study, we observed bone formation surrounding Mg devices, with complete overgrowth by 16 weeks. Bend tests revealed no difference in flexural load of healed ulnae with Mg devices compared to intact ulnae. These data suggest that Mg devices provide stabilization to facilitate healing, while degrading and stimulating new bone formation. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  9. Optimal screw placement for base plate fixation in reverse total shoulder arthroplasty.

    PubMed

    DiStefano, James Guido; Park, Andrew Y; Nguyen, Thuc-Quyen D; Diederichs, Gerd; Buckley, Jenni M; Montgomery, William H

    2011-04-01

    Scapular cortical thickness has not been fully characterized from the perspective of determining optimal screw placement for securing the glenoid base plate in reverse shoulder arthroplasty. Twelve fresh frozen cadaveric scapulae underwent high resolution CT scans with 3-dimensional reconstructions and wall thickness analysis. Digital base plates were positioned and virtual screws were placed according to 2 scenarios: A - intraosseous through the entire course and exits a "safe region" with no known neurovascular structures; B - may leave and re-enter the bone and penetrates the thickest cortical region accessible regardless of adjacent structures. For scenario A, the optimal screw configurations were: (superior screw) length = 35 mm, 9° superior, 2° posterior; (inferior screw-A) length = 34 mm, 16° inferior, 5° anterior; (inferior screw-B) length = 31 mm, 31 inferior, 4 posterior; (posterior screw) length 19 mm, 29° inferior, 3° anterior. For scenario B: (superior screw) length = 36 mm, 28° superior, 10° anterior; (inferior screw) length = 35 mm, 19° inferior, 4° anterior; (posterior screw) length 37 mm, 23° superior, 3° anterior. The anterior screw was consistent between scenarios A and B, averaged 29 mm in length and was directed 16° inferior and 14° posterior. Thicker cortical regions were present in the lateral aspect of the suprascapular notch, scapular spine base, anterior/superior aspect of inferior pillar and junction of glenoid neck and scapular spine. Regions with high cortical thickness were accessible for both scenarios except for the posterior screw in scenario A. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  10. A comparison of parallel and diverging screw angles in the stability of locked plate constructs.

    PubMed

    Wähnert, D; Windolf, M; Brianza, S; Rothstock, S; Radtke, R; Brighenti, V; Schwieger, K

    2011-09-01

    We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm(3)) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations. In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading.

  11. The use of biodegradable plates and screws to stabilize facial fractures.

    PubMed

    Bell, R Bryan; Kindsfater, Craig S

    2006-01-01

    The purpose of this preliminary retrospective study was to review the demographics and outcome of patients with a variety of facial fractures that were stabilized with PL bone plates and screws. The records of 295 consecutive patients with facial fractures treated by open reduction and internal fixation, performed by the author from 2001 through 2004, were retrospectively reviewed. Patients were selected to receive biodegradable fixation on the basis of mechanism of injury, the degree of bony displacement demonstrated on clinical and radiographic examination, patient age, and fracture pattern or location. Outcome measures such as infection, non-union, and mal-union were identified and subjectively assessed. Descriptive statistics were recorded and analyzed. Two hundred eighty-one patients met the criteria for inclusion in the study with follow-up of 3 weeks to 3 years. Fifty-nine (21%) patients were identified as having received biodegradable plates and screws. All patients eventually went on to satisfactory healing with favorable restoration of form and function. Complications occurred in 16 patients overall (6%). Of these, 2 patients were treated with resorbable plates and screws; 1 patient with a zygomatico-maxillary complex fracture developed a sterile abscess that presented 1 year postoperatively and responded to local measures. Another patient with a Le Fort I fracture developed an anterior open bite necessitating Le Fort I osteotomy for correction. Favorable healing can be observed through the use of biodegradable PL plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood.

  12. Effect of Real-Time Feedback on Screw Placement Into Synthetic Cancellous Bone.

    PubMed

    Gustafson, Peter A; Geeslin, Andrew G; Prior, David M; Chess, Joseph L

    2016-08-01

    The objective of this study is to evaluate whether real-time torque feedback may reduce the occurrence of stripping when inserting nonlocking screws through fracture plates into synthetic cancellous bone. Five attending orthopaedic surgeons and 5 senior level orthopaedic residents inserted 8 screws in each phase. In phase I, screws were inserted without feedback simulating conventional techniques. In phase II, screws were driven with visual torque feedback. In phase III, screws were again inserted with conventional techniques. Comparison of these 3 phases with respect to screw insertion torque, surgeon rank, and perception of stripping was used to establish the effects of feedback. Seventy-three of 239 screws resulted in stripping. During the first phase, no feedback was provided and the overall strip rate was 41.8%; this decreased to 15% with visual feedback (P < 0.001) and returned to 35% when repeated without feedback. With feedback, a lower average torque was applied over a narrower torque distribution. Residents stripped 40.8% of screws compared with 20.2% for attending surgeons. Surgeons were poor at perceiving whether they stripped. Prevention and identification of stripping is influenced by surgeon perception of tactile sensation. This is significantly improved with utilization of real-time visual feedback of a torque versus roll curve. This concept of real-time feedback seems beneficial toward performance in synthetic cancellous bone and may lead to improved fixation in cancellous bone in a surgical setting.

  13. Comparison of the Mechanical Characteristics of a Universal Small Biplane Plating Technique Without Compression Screw and Single Anatomic Plate With Compression Screw.

    PubMed

    Dayton, Paul; Ferguson, Joe; Hatch, Daniel; Santrock, Robert; Scanlan, Sean; Smith, Bret

    2016-01-01

    To better understand the mechanical characteristics of biplane locked plating in small bone fixation, the present study compared the stability under cyclic cantilever loading of a 2-plate locked biplane (BPP) construct without interfragmentary compression with that of a single-plate locked construct with an additional interfragmentary screw (SPS) using surrogate bone models simulating Lapidus arthrodesis. In static ultimate plantar bending, the BPP construct failed at significantly greater load than did the SPS construct (556.2 ± 37.1 N versus 241.6 ± 6.3 N, p = .007). For cyclic failure testing in plantar bending at a 180-N starting load, the BPP construct failed at a significantly greater number of cycles (158,322 ± 50,609 versus 13,718 ± 10,471 cycles) and failure load (242.5 ± 25.0 N versus 180.0 ± 0.0 N) than the SPS construct (p = .002). For cyclic failure testing in plantar bending at a 120-N starting load, the results were not significantly different between the BPP and SPS constructs for the number of cycles (207,646 ± 45,253 versus 159,334 ± 69,430) or failure load (205.0 ± 22.4 N versus 185.0 ± 33.5 N; p = .300). For cyclic testing with 90° offset loading (i.e., medial to lateral bending) at a 120-N starting load, all 5 BPP constructs (tension side) and 2 of the 5 SPS constructs reached 250,000 cycles without failure. Overall, the present study found the BPP construct to have superior or equivalent stability in multiplanar orientations of force application in both static and fatigue testing. Thus, the concept of biplane locked plating, using 2 low profile plates and unicortical screw insertion, shows promise in small bone fixation, because it provides consistent stability in multiplanar orientations, making it universally adaptable to many clinical situations. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates.

    PubMed

    Ioannou, Christopher; Knight, Matthew; Daniele, Luca; Flueckiger, Lee; Tan, Ezekiel S L

    2016-10-17

    The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. Torque for both hand and power screw insertion was measured through a load cell, registering 6.66 points per second. This was performed in a controlled environment using synthetic bone, a locking plate and locking screws to simulate plate fixation. Screws were inserted by hand and by drill with torque values measured. The surgical torque limiter (1.5 Nm) was effective as the highest recorded reading in the study was 1.409 Nm. Comparatively, there is a statistically significant difference between screw insertion methods. Torque produced for manually driven screw insertion into locking plates was 1.289 Nm (95 % CI 1.269-1.308) with drill-powered screw insertion at 0.740 Nm (95 % CI 0.723-0.757). The surgical torque limiter proved to be effective as per product specifications. Screws inserted under power produce significantly less torque when compared to manual insertion by hand. This is likely related to the mechanism of the torque limiter when being used at higher speeds for which it was designed. We conclude that screws may be inserted using power to the plate with the addition of a torque limiter. It is recommended that all screws inserted by drill be hand tightened to achieve adequate torque values.

  15. Modeling bicortical screws under a cantilever bending load.

    PubMed

    James, Thomas P; Andrade, Brendan A

    2013-12-01

    Cyclic loading of surgical plating constructs can precipitate bone screw failure. As the frictional contact between the plate and the bone is lost, cantilever bending loads are transferred from the plate to the head of the screw, which over time causes fatigue fracture from cyclic bending. In this research, analytical models using beam mechanics theory were developed to describe the elastic deflection of a bicortical screw under a statically applied load. Four analytical models were developed to simulate the various restraint conditions applicable to bicortical support of the screw. In three of the models, the cortical bone near the tip of the screw was simulated by classical beam constraints (1) simply supported, (2) cantilever, and (3) split distributed load. In the final analytical model, the cortices were treated as an elastic foundation, whereby the response of the constraint was proportional to screw deflection. To test the predictive ability of the new analytical models, 3.5 mm cortical bone screws were tested in a synthetic bone substitute. A novel instrument was developed to measure the bending deflection of screws under radial loads (225 N, 445 N, and 670 N) applied by a surrogate surgical plate at the head of the screw. Of the four cases considered, the analytical model utilizing an elastic foundation most accurately predicted deflection at the screw head, with an average difference of 19% between the measured and predicted results. Determination of the bending moments from the elastic foundation model revealed that a maximum moment of 2.3 N m occurred near the middle of the cortical wall closest to the plate. The location of the maximum bending moment along the screw axis was consistent with the fracture location commonly observed in clinical practice.

  16. Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate system.

    PubMed

    Voss, K; Kull, M; Hässig, M; Montavon, P

    2009-01-01

    To retrospectively evaluate stabilisation of long-bone fractures in cats and small dogs using the Unilock system. Medical histories and radiographs of consecutive patients with long-bone fractures stabilised with the Unilock system were reviewed. Cases with follow-up radiographs taken at least four weeks postoperatively were included. Signalment of the patient, fracture localisation and type, primary fracture repair or revision surgery, single or double plating, and complications for each patient were noted. Additionally, implant size, number of screws, number of cortices engaged with screws, and number of empty holes across the fracture were evaluated in fractures where a single plate had been applied. Eighteen humeral, 18 radial, 20 femoral, and 10 tibial fractures were treated. The Unilock system was used for primary repair in 44 fractures and for revision surgery in 22 fractures. Two plates were applied in 17 fractures, and a single plate was applied in 49 fractures. Follow-up radiographs were taken four to 109 weeks postoperatively. Complications were seen in 12 animals and 13 fractures (19.7%). Fixation failure occurred in seven fractures (10.6%). Cases with a single plate that suffered fixation failure had thinner screws in relation to bone diameter than cases with double plates, and more screws in a main fragment than those without fixation failure. The Unilock system is a suitable implant for fracture fixation of long bones in cats and small dogs.

  17. Easy and Inexpensive Technique for Removal of Round Headed, Jammed Locking Screws in Distal Tibial Interlocking Plate.

    PubMed

    Singh, Harpreet; Sharma, Rohit; Gupta, Sachin; Singh, Narinderjit; Singh, Simarpreet

    2015-01-01

    The advent of locking plates has brought new problems in implant removal. Difficulty in removing screws from a locking plate is well-known. These difficulties include cold welding between the screw head and locking screw hole, stripping of the recess of the screw head for the screwdriver, and cross-threading between threads in the screw head and screw hole. However, there are cases in which removal is difficult. We describe a new technique for removing a round headed, jammed locking screws from a locking plate. 55 years old male patient received a locking distal tibial plate along with distal fibular plate 3years back from UAE. Now patient came with complaint of non-healing ulcer over medial aspect of lower 1/3rd of right leg from past 1 year. Non operative management did not improve the symptoms. The patient consented to implant removal, with the express understanding that implant removal might be impossible because already one failed attempt had been performed at some other hospital six months back. We then decided to proceed with the new technique. The rest of the proximal screws were removed using a technique not previously described. We used stainless steel metal cutting blades that are used to cut door locks or pad locks to cut the remaining stripped headed screws. This technique is very quick, easy to perform and inexpensive because the metal cutting blades which are used to cut the screws are very cheap. Yet it is very effective technique to remove the stripped headed or jammed locking screws. It is also very less destructive because of very less heat production during the procedure there is no problem of thermal necrosis to the bone or the surrounding soft tissue.

  18. A Passive and Wireless Sensor for Bone Plate Strain Monitoring.

    PubMed

    Tan, Yisong; Hu, Jiale; Ren, Limin; Zhu, Jianhua; Yang, Jiaqi; Liu, Di

    2017-11-16

    This paper reports on a sensor for monitoring bone plate strain in real time. The detected bone plate strain could be used for judging the healing state of fractures in patients. The sensor consists of a magnetoelastic material, which can be wirelessly connected and passively embedded. In order to verify the effectiveness of the sensor, a tibia-bone plate-screw (TBS) model was established using the finite element analysis method. A variation of the bone plate strain was obtained via this model. A goat hindquarter tibia was selected as the bone fracture model in the experiment. The tibia was fixed on a high precision load platform and an external force was applied. Bone plate strain variation during the bone fracture healing process was acquired with sensing coils. Simulation results indicated that bone plate strain decreases as the bone gradually heals, which is consistent with the finite element analysis results. This validated the soundness of the sensor reported here. This sensor has wireless connections, no in vivo battery requirement, and long-term embedding. These results can be used not only for clinical practices of bone fracture healing, but also for bone fracture treatment and rehabilitation equipment design.

  19. An approximate model for cancellous bone screw fixation.

    PubMed

    Brown, C J; Sinclair, R A; Day, A; Hess, B; Procter, P

    2013-04-01

    This paper presents a finite element (FE) model to identify parameters that affect the performance of an improved cancellous bone screw fixation technique, and hence potentially improve fracture treatment. In cancellous bone of low apparent density, it can be difficult to achieve adequate screw fixation and hence provide stable fracture fixation that enables bone healing. Data from predictive FE models indicate that cements can have a significant potential to improve screw holding power in cancellous bone. These FE models are used to demonstrate the key parameters that determine pull-out strength in a variety of screw, bone and cement set-ups, and to compare the effectiveness of different configurations. The paper concludes that significant advantages, up to an order of magnitude, in screw pull-out strength in cancellous bone might be gained by the appropriate use of a currently approved calcium phosphate cement.

  20. Ultrasound melted polymer sleeve for improved screw anchorage in trabecular bone--A novel screw augmentation technique.

    PubMed

    Schmoelz, W; Mayr, R; Schlottig, F; Ivanovic, N; Hörmann, R; Goldhahn, J

    2016-03-01

    Screw anchorage in osteoporotic bone is still limited and makes treatment of osteoporotic fractures challenging for surgeons. Conventional screws fail in poor bone quality due to loosening at the screw-bone interface. A new technology should help to improve this interface. In a novel constant amelioration process technique, a polymer sleeve is melted by ultrasound in the predrilled screw hole prior to screw insertion. The purpose of this study was to investigate in vitro the effect of the constant amelioration process platform technology on primary screw anchorage. Fresh frozen femoral heads (n=6) and vertebrae (n=6) were used to measure the maximum screw insertion torque of reference and constant amelioration process augmented screws. Specimens were cut in cranio-caudal direction, and the screws (reference and constant amelioration process) were implanted in predrilled holes in the trabecular structure on both sides of the cross section. This allowed the pairwise comparison of insertion torque for constant amelioration process and reference screws (femoral heads n=18, vertebrae n=12). Prior to screw insertion, a micro-CT scan was made to ensure comparable bone quality at the screw placement location. The mean insertion torque for the constant amelioration process augmented screws in both, the femoral heads (44.2 Ncm, SD 14.7) and the vertebral bodies (13.5 Ncm, SD 6.3) was significantly higher than for the reference screws of the femoral heads (31.7 Ncm, SD 9.6, p<0.001) and the vertebral bodies (7.1 Ncm, SD 4.5, p<0.001). The interconnection of the melted polymer sleeve with the surrounding trabecular bone in the constant amelioration process technique resulted in a higher screw insertion torque and can improve screw anchorage in osteoporotic trabecular bone. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Hyoid expansion with titanium plate and screw: a human cadaveric study using computer-assisted airway measurement.

    PubMed

    Toh, Song-Tar; Hsu, Pon-Poh; Tan, Kah Leong Alvin; Lu, Kuo-Sun Peter; Han, Hong-Juan

    2013-08-01

    Hyoid expansion with suspension can potentially increase the upper airway at the hypopharyngeal level, benefitting patients with sleep-related breathing disorder. To document the effect of hyoid expansion using titanium plate and screw on retrolingual hypopharyngeal airway dimension and to compare the airway dimension after isolated hyoid expansion with hyoid expansion + hyomandibular suspension. Anatomical cadaveric dissection study. This study was performed in a laboratory setting using human cadavers. This is an anatomical feasibility study of hyoid expansion using titanium plate and screw on 10 cadaveric human heads and necks. The hyoid bone is trifractured with bony cuts made just medial to the lesser cornu. The freed hyoid body and lateral segments are expanded and stabilized to a titanium adaptation plate. Computer-assisted airway measurement (CAM) was used to measure the airway dimension at the hypopharynx at the level of the tongue base before and after the hyoid expansion. The expanded hyoid bone was then suspended to the mandible, and the airway dimension was measured again with CAM. Airway dimension after isolated hyoid expansion with hyoid expansion with hyomandibular suspension. RESULTS Hyoid expansion with titanium plate and screw resulted in statistical significant increase in the retrolingual hypopharyngeal airway space in all of the 10 human cadavers. The mean (SD) increase in retroglossal area was 33.4 (13.2) mm² (P < .005) (range, 6.0-58.7 mm²). Hyoid expansion with hyomandibular suspension resulted in a greater degree of airway enlargement. The mean (SD) increase in retroglossal area was 99.4 (15.0) mm² (P < .005) (range, 81.9-127.5 mm²). The retrolingual hypopharyngeal airway space increased with hyoid expansion using titanium plate and screw in our human cadaveric study, measured using CAM. The degree of increase is further augmented with hyomandibular suspension.

  2. Minimally invasive plate augmentation in the treatment of long-bone non-unions.

    PubMed

    Park, Ki-Chul; Oh, Chang-Wug; Kim, Joon-Woo; Park, Kyeong-Hyeon; Oh, Jong-Keon; Park, Il-Hyung; Kyung, Hee-Soo; Heo, Jeong

    2017-11-01

    Exchange nailing is most acceptable for treating hypertrophic non-union of the long bones, requiring the removal of previously fixed implant. However, its main effect of mechanical stabilization is controversial in non-isthmal area. We hypothesized that minimally invasive plate augmentation over the non-union site may have a better option, without the need of bone grafting or removing pre-existing implants. Seventeen patients with hypertrophic non-union of the long bones between 2010 and 2014 on radiography who previously underwent intramedullary (IM) nailing or plate osteosynthesis for long-bone fractures were included. A locking compression plate was inserted with at least three mono- or bicortical screws at each proximal and distal segment. Broken or loosened interlocking screws of IM nail were simultaneously re-fixed. Fracture site exposure, pre-fixed implant removal, and bone grafting were not performed. We investigated whether union occurred and analyzed functional outcomes and complications. Eleven femoral and six tibial non-unions were prospectively included. In the pre-existing implants, 13 nails and 4 plates were found. All cases achieved union at a mean 22.7 weeks. One case of superficial infection was managed with oral antibiotics. Deep infection or implant failure did not occur. Minimally invasive plate augmentation can achieve additional stability and promote healing of hypertrophic non-union of the long bones. When indicated, this technique is the least invasive alternative to exchange nailing and reduces surgical risks in the treatment of diaphyseal non-union.

  3. A simple method to ensure proper screw position and plate size selection using the Morscher cervical spine locking plate. Technical note.

    PubMed

    Ball, P A; Benzel, E C; Baldwin, N G

    1994-04-01

    The use of bone plate instrumentation with screw fixation has proved to be a useful adjunctive measure in anterior cervical spine fusion surgery. Proper fitting, positioning, and attachment of this instrumentation have been shown to be frequently suboptimal if done without radiographic guidance. The most commonly used method of radiographic assistance for placement of this instrumentation is fluoroscopy. While this gives satisfactory technical results, it is expensive and time-consuming, and exposes the patient and the operating room personnel to ionizing radiation. The authors present a simple technique to ensure screw placement and plate fitting using Kirschner wires and a single lateral radiograph. This technique saves time, reduces exposure to radiation, and has led to satisfactory results in over 20 operative cases.

  4. Release of metal in vivo from stressed and nonstressed maxillofacial fracture plates and screws.

    PubMed

    Matthew, I R; Frame, J W

    2000-07-01

    To analyze the release of metal into the adjacent tissues from stressed and nonstressed titanium and stainless steel miniplates and screws. Two miniplates were inserted into the cranial vaults of 12 beagle dogs while they were under general endotracheal anesthesia. One miniplate was shaped to fit the curvature of the skull (control). Another miniplate, made of the same material, was bent in a curve until the midpoint was raised 3 mm above the ends. Screws were inserted and tightened until the plate conformed to the skull curvature, creating stresses in the system. Four animals (2 each, having titanium or stainless steel plates and screws) were killed after 4, 12, and 24 weeks. Metallosis of adjacent soft tissues was assessed qualitatively. Miniplates and screws were removed, and adjacent soft tissue and bone was excised. Titanium, iron, chromium, nickel, and aluminum levels were assayed by ultraviolet/visible light and atomic absorption spectrophotometry. Nonparametric statistical methods were used for data analysis. There was no clear relationship between pigmentation of soft tissue adjacent to the miniplates and screws and the concentrations of metal present. The data did not demonstrate any consistent differences in the concentrations of metallic elements next to stressed and nonstressed (control) miniplates and screws of either material. Stresses arising through poor contouring of miniplates do not appear to influence the extent of release of metal into the adjacent tissues.

  5. Torsional Growth Modulation of Long Bones by Oblique Plating in a Rabbit Model.

    PubMed

    Lazarus, David E; Farnsworth, Christine L; Jeffords, Megan E; Marino, Nikolas; Hallare, Jericho; Edmonds, Eric W

    2018-02-01

    There is evidence that oblique tension band plating can affect torsional growth in long bones. This study sought to determine if the torsional growth could be modulated based on the angles of the tension band plating and whether or not oblique plating affected overall longitudinal growth. New Zealand White rabbits (10.5 wk old) had one screw placed on the metaphyseal side and one on the epiphyseal side of both medial and lateral sides of the right knee distal femoral physis. The sham group (n=5) included screw placement only. For the plate group (n=13), unlocked plates, angled from 0 to 76 degrees, connected the screws and spanned the physis. Radiographs were taken at biweekly intervals. After 6 weeks of growth, hindlimbs were harvested and microCT scans performed. Femoral length, distances between screw heads and angle between the plates were measured on radiographs. Femoral length differences were compared between groups. Femoral version was measured from 3D microCT. Plate angle changes were correlated to the difference in femoral version between limbs using Pearson correlation (significance was set to P<0.05 for all comparisons). Femur length difference between the contralateral and the operative side was significantly greater in the plate group compared with the sham group over time (P=0.049). Medial and lateral screw distances changed significantly more in the sham group than the plate group on both sides (P<0.001). A greater initial angle between plates resulted in a greater change in the angle between plates (P<0.001). Significant correlations were found between right-left side femoral version differences and initial plate angle (P=0.003) and plate angle change (P=0.014). The torsional effect of oblique plating seems to correlate with the amount of initial plate angle, with an additional, not negligible, longitudinal growth effect. Placing plates at given angles across open physes may result in predictable changes in bone torsion allowing for a safer and

  6. [Biphasic ceramic wedge and plate fixation with locked adjustable screws for open wedge tibial osteotomy].

    PubMed

    Lavallé, F; Pascal-Mousselard, H; Rouvillain, J L; Ribeyre, D; Delattre, O; Catonné, Y

    2004-10-01

    The aim of this radiological study was to evaluate the use of a biphasic ceramic wedge combined with plate fixation with locked adjustable screws for open wedge tibial osteotomy. Twenty-six consecutive patients (27 knees) underwent surgery between December 1999 and March 2002 to establish a normal lower-limb axis. The series included 6 women and 20 men, mean age 50 years (16 right knees and 11 left knees). Partial weight-bearing with crutches was allowed on day 1. A standard radiological assessment was performed on day 1, 90, and 360 (plain AP and lateral stance films of the knee). A pangonogram was performed before surgery and at day 360. Presence of a lateral metaphyseal space, development of peripheral cortical bridges, and osteointegration of the bone substitute-bone interface were evaluated used to assess bone healing. The medial tibial angle between the line tangent to the tibial plateau and the anatomic axis of the tibia (beta) was evaluated to assess preservation of postoperative correction. The HKA angle was determined. Three patients were lost to follow-up and 23 patients (24 knees) were retained for analysis. At last follow-up, presence of peripheral cortical bridges and complete filling of the lateral metaphyseal space demonstrated bone healing in all patients. Good quality osteointegration was achieved since 21 knees did not present an interface between the bone substitute and native bone (homogeneous transition zone). The beta angle was unchanged for 23 knees. A normal axis was observed in patients (16 knees) postoperatively. Use of a biphasic ceramic wedge in combination with plate fixation with locked adjustable screws is a reliable option for open wedge tibial osteotomy. The bone substitute fills the gap well. Tolerance and integration are optimal. Bone healing is achieved. Plate fixation with protected weight bearing appears to be a solid assembly, maintaining these corrections.

  7. Self-designed posterior atlas polyaxial lateral mass screw-plate fixation for unstable atlas fracture.

    PubMed

    He, Baorong; Yan, Liang; Zhao, Qinpeng; Chang, Zhen; Hao, Dingjun

    2014-12-01

    Most atlas fractures can be effectively treated nonoperatively with external immobilization unless there is an injury to the transverse atlantal ligament. Surgical stabilization is most commonly achieved using a posterior approach with fixation of C1-C2 or C0-C2, but these treatments usually result in loss of the normal motion of the C1-C2 and C0-C1 joints. To clinically validate feasibility, safety, and value of open reduction and fixation using an atlas polyaxial lateral mass screw-plate construct in unstable atlas fractures. Retrospective review of patients who sustained unstable atlas fractures treated with polyaxial lateral mass screw-plate construct. Twenty-two patients with unstable atlas fractures who underwent posterior atlas polyaxial lateral mass screw-plate fixation were analyzed. Visual analog scale, neurologic status, and radiographs for fusion. From January 2011 to September 2012, 22 patients with unstable atlas fractures were treated with this technique. Patients' charts and radiographs were reviewed. Bone fusion, internal fixation placement, and integrity of spinal cord and vertebral arteries were assessed via intraoperative and follow-up imaging. Neurologic function, range of motion, and pain levels were assessed clinically on follow-up. All patients were followed up from 12 to 32 months, with an average of 22.5±18.0 months. A total of 22 plates were placed, and all 44 screws were inserted into the atlas lateral masses. The mean duration of the procedure was 86 minutes, and the average estimated blood loss was 120 mL. Computed tomography scans 9 months after surgery confirmed that fusion was achieved in all cases. There was no screw or plate loosening or breakage in any patient. All patients had well-preserved range of motion. No vascular or neurologic complication was noted, and all patients had a good clinical outcome. An open reduction and posterior internal fixation with atlas polyaxial lateral mass screw-plate is a safe and effective

  8. Contact between the acetabulum and dome of a Kerboull-type plate influences the stress on the plate and screw.

    PubMed

    Hara, Katsutoshi; Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-07-01

    We used a three-dimensional finite element method to investigate the conditions behind the Kerboull-type (KT) dome. The KT plate dome was divided into five areas, and 14 models were created to examine different conditions of dome contact with the acetabulum. The maximum stress on the KT plate and screws was estimated for each model. Furthermore, to investigate the impact of the contact area with the acetabulum on the KT plate, a multiple regression analysis was conducted using the analysis results. The dome-acetabulum contact area affected the maximum equivalent stress on the KT plate; good contact with two specific areas of the vertical and horizontal beams (Areas 3 and 5) reduced the maximum equivalent stress. The maximum equivalent stress on the hook increased when the hardness of the bone representing the acetabulum varied. Thus, we confirmed the technical importance of providing a plate with a broad area of appropriate support from the bone and cement in the posterior portion of the dome and also proved the importance of supporting the area of the plate in the direction of the load at the center of the cross-plate and near the hook.

  9. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis.

    PubMed

    Zhang, Ya-Kui; Wei, Hung-Wen; Lin, Kang-Ping; Chen, Wen-Chuan; Tsai, Cheng-Lun; Lin, Kun-Jhih

    2016-06-01

    Locking plate fixation for proximal humeral fractures is a commonly used device. Recently, plate breakages were continuously reported that the implants all have a mixture of holes allowing placement of both locking and non-locking screws (so-called combi plates). In commercialized proximal humeral plates, there still are two screw hole styles included "locking and dynamic holes separated" and "locking hole only" configurations. It is important to understand the biomechanical effect of different screw hole style on the stress distribution in bone plate. Finite element method was employed to conduct a computational investigation. Three proximal humeral plate models with different screw hole configurations were reconstructed depended upon an identical commercialized implant. A three-dimensional model of a humerus was created using process of thresholding based on the grayscale values of the CT scanning of an intact humerus. A "virtual" subcapital osteotomy was performed. Simulations were performed under an increasing axial load. The von Mises stresses around the screw holes of the plate shaft, the construct stiffness and the directional displacement within the fracture gap were calculated for comparison. The mean value of the peak von Mises stresses around the screw holes in the plate shaft was the highest for combi hole design while it was smallest for the locking and dynamic holes separated design. The stiffness of the plate-bone construct was 15% higher in the locking screw only design (132.6N/mm) compared with the combi design (115.0N/mm), and it was 4% higher than the combi design for the locking and dynamic holes separated design (119.5N/mm). The displacement within the fracture gap was greatest in the combi hole design, whereas it was smallest for the locking hole only design. The computed results provide a possible explanation for the breakages of combi plates revealed in clinical reports. The locking and dynamic holes separated design may be a better

  10. Experimental analysis of internal rigid fixation osteosynthesis performed with titanium bone screw and plate systems.

    PubMed

    Righi, E; Carta, M; Bruzzone, A A; Lonardo, P M; Marinaro, E; Pastorino, A

    1996-02-01

    The authors report the results of an experimental analysis performed on titanium miniplates and screws in order to gain a better understanding of dynamic forces in internal rigid fixation. Ten segments of bovine scapula were prepared. Osteotomies were carried out along the minor axis, following which five were fixed with four hole straight miniplates and the other five with six hole double-Y miniplates. Each sample was fastened in a special clamp adapted to a tension test machine and shearing force was applied. Force versus time was recorded and the 50 bone fragments were examined by a pathologist. On the basis of the test results, two simple computer models were developed. No significant difference was evident between the mechanical and computed tests. The most critical sections were located near the hole proximal to the osteotomy and the microscopic findings confirmed this. On the basis of the experimental results, the authors propose a new plate design in which the area subject to most stress, proximal to the bone section, would be of miniplate thickness, the distal aspect being thinner as in a microplate. It is suggested that this design would provide sufficient stability and a high degree of anatomical adjustment of the system.

  11. Three point lead screw positioning apparatus for a cavity tuning plate

    NASA Technical Reports Server (NTRS)

    Calco, Frank S. (Inventor)

    1993-01-01

    Three lead screws are provided for adjusting the position of a traversing plate. Each of the three lead screws is threaded through a collar that is press fitted through the center of one of three pinion gears. A sun gear meshes with all three pinion gears and transversely moves the three lead screws upon actuation of a drive gear. The drive gear meshes with the sun gear and is driven by a handle or servomotor. When the handle or servomotor rotates the drive gear, the sun gear rotates causing the three pinion gears to rotate, thus, causing transverse movement of the three lead screws and, accordingly, transverse movement of the transversing plate. When the drive gear rotates, the traversing plate is driven in and out of a microwave cavity. Thus, the length or size of the cavity can be tuned while maintaining the traversing plate in an exact parallel relationship with an opposing plate on another end of the cavity.

  12. Three point lead screw positioning apparatus for a cavity tuning plate

    NASA Astrophysics Data System (ADS)

    Calco, Frank S.

    1993-09-01

    Three lead screws are provided for adjusting the position of a traversing plate. Each of the three lead screws is threaded through a collar that is press fitted through the center of one of three pinion gears. A sun gear meshes with all three pinion gears and transversely moves the three lead screws upon actuation of a drive gear. The drive gear meshes with the sun gear and is driven by a handle or servomotor. When the handle or servomotor rotates the drive gear, the sun gear rotates causing the three pinion gears to rotate, thus, causing transverse movement of the three lead screws and, accordingly, transverse movement of the transversing plate. When the drive gear rotates, the traversing plate is driven in and out of a microwave cavity. Thus, the length or size of the cavity can be tuned while maintaining the traversing plate in an exact parallel relationship with an opposing plate on another end of the cavity.

  13. Factors affecting the pullout strength of cancellous bone screws.

    PubMed

    Chapman, J R; Harrington, R M; Lee, K M; Anderson, P A; Tencer, A F; Kowalski, D

    1996-08-01

    Screws placed into cancellous bone in orthopedic surgical applications, such as fixation of fractures of the femoral neck or the lumbar spine, can be subjected to high loads. Screw pullout is a possibility, especially if low density osteoporotic bone is encountered. The overall goal of this study was to determine how screw thread geometry, tapping, and cannulation affect the holding power of screws in cancellous bone and determine whether current designs achieve maximum purchase strength. Twelve types of commercially available cannulated and noncannulated cancellous bone screws were tested for pullout strength in rigid unicellular polyurethane foams of apparent densities and shear strengths within the range reported for human cancellous bone. The experimentally derived pullout strength was compared to a predicted shear failure force of the internal threads formed in the polyurethane foam. Screws embedded in porous materials pullout by shearing the internal threads in the porous material. Experimental pullout force was highly correlated to the predicted shear failure force (slope = 1.05, R2 = 0.947) demonstrating that it is controlled by the major diameter of the screw, the length of engagement of the thread, the shear strength of the material into which the screw is embedded, and a thread shape factor (TSF) which accounts for screw thread depth and pitch. The average TSF for cannulated screws was 17 percent lower than that of noncannulated cancellous screws, and the pullout force was correspondingly less. Increasing the TSF, a result of decreasing thread pitch or increasing thread depth, increases screw purchase strength in porous materials. Tapping was found to reduce pullout force by an average of 8 percent compared with nontapped holes (p = 0.0001). Tapping in porous materials decreases screw pullout strength because the removal of material by the tap enlarges hole volume by an average of 27 percent, in effect decreasing the depth and shear area of the internal

  14. Effect of insertion torque on bone screw pullout strength.

    PubMed

    Lawson, K J; Brems, J

    2001-05-01

    The effect of insertion torque on the holding strength of 4.5-mm ASIF/AO cortical bone screws was studied in vitro. Screw holding strength was determined using an Instron materials testing machine (Bristol, United Kingdom) on 55 lamb femora and 30 human tibiocortical bone sections. Holding strength was defined as tensile stress at pullout with rapid loading to construct failure. Different insertion torques were tested, normalizing to the thickness of cortical bone specimen engaged. These represented low, intermediate, high, and thread-damaging insertion torque. All screws inserted with thread-damaging torque and single cortex engaging screws inserted to high torque tightening moments showed diminished holding strength. This loss of strength amounted to 40%-50% less than screws inserted with less torque.

  15. Locking design affects the jamming of screws in locking plates.

    PubMed

    Sandriesser, Sabrina; Rupp, Markus; Greinwald, Markus; Heiss, Christian; Augat, Peter; Alt, Volker

    2018-06-01

    The seizing of locking screws is a frequently encountered clinical problem during implant removal of locking compression plates (LCP) after completion of fracture healing. The aim of this study was to investigate the effect of two different locking mechanisms on the seizing of locking screws. Specifically, the removal torques before and after cyclic dynamic loading were assessed for screws inserted at the manufacturer-recommended torque or at an increased insertion torque. The seizing of 3.5-mm angular stable screws was assessed as a function of insertion torque for two different locking mechanisms (Thread & Conus and Thread Only). Locking screws (n=10 for each configuration) were inserted either according to the manufacturer-recommended torque or at an increased torque of 150% to simulate an over-insertion of the screw. Half of the screws were removed directly after insertion and the remaining half was removed after a dynamic load protocol of 100,000 cycles. The removal torques of locking screws exceeded the insertion torques for all tested conditions confirming the adequacy of the test setup in mimicking screw seizing in locked plating. Screw seizing was more pronounced for Thread Only design (+37%) compared to Thread & Conus design (+14%; P<0.0001). Cyclic loading of the locking construct consistently resulted in an increased seizing of the locking screws (P<0.0001). Clinical observations from patients treated with the Thread & Conus locking design confirm the biomechanical findings of reduction in seizing effect by using a Thread & Conus design. In conclusion, both over-tightening and cyclic loading are potential causes for screw seizing in locking plate implants. Both effects were found to be less pronounced in the Thread & Conus design as compared to the traditional Thread Only design. © 2018 Elsevier Ltd. All rights reserved.

  16. Locked plating of comminuted distal femur fractures: does unlocked screw placement affect stability and failure?

    PubMed

    Cui, Shari; Bledsoe, J G; Israel, Heidi; Watson, J T; Cannada, Lisa K

    2014-02-01

    Locked plates provide greater stiffness, possibly at the expense of fracture healing. The purpose of this study is to evaluate construct stiffness of distal femur plates as a function of unlocked screw position in cadaveric distal femur fractures. Osteoporotic cadaveric femurs were used. Four diaphyseal bridge plate constructs were created using 13-hole distal femur locking plates, all with identical condylar fixation. Constructs included all locked (AL), all unlocked (AUL), proximal unlocked (PUL), and distally unlocked (DUL) groups. Constructs underwent cyclic axial loading with increasing force per interval. Data were gathered on axial stiffness, torsional stiffness, maximum torque required for 5-degree external rotation, and axial force to failure. Twenty-one specimens were divided into AL, AUL, PUL, and DUL groups. Axial stiffness was not significantly different between the constructs. AL and PUL demonstrated greater torsional stiffness, maximum torque, and force to failure than AUL and AL showed greater final torsional stiffness and failure force than DUL (P < 0.05). AL and PUL had similar axial, torsion, and failure measures, as did AUL and DUL constructs. All but 2 specimens fractured before medial gap closure during failure tests. Drop-offs on load-displacement curves confirmed all failures. Only the screw nearest the gap had significant effect on torsional and failure stiffness but not axial stiffness. Construct mechanics depended on the type of screw placed in this position. This screw nearest the fracture dictates working length stiffness when the working length itself is constant and in turn determines overall construct stiffness in osteoporotic bone.

  17. Complicated sternal dehiscence: reconstruction with plates, cables, and cannulated screws.

    PubMed

    Voss, Bernhard; Bauernschmitt, Robert; Brockmann, Gernot; Krane, Markus; Will, Albrecht; Lange, Rüdiger

    2009-04-01

    Sternal dehiscence after median sternotomy can be a challenging problem in case of multiple fractures or infection. For sternal refixation, the principles of rigid plate and screw osteosynthesis gained from orthopedic surgery have been recommended by several authors. We present a new system for sternal reconstruction consisting of reconstruction plates, steel cables, and cannulated screws.

  18. Fracture healing using degradable magnesium fixation plates and screws.

    PubMed

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Noorani, Sabrina; Costello, Bernard J; Sfeir, Charles

    2015-02-01

    Internal bone fixation devices made with permanent metals are associated with numerous long-term complications and may require removal. We hypothesized that fixation devices made with degradable magnesium alloys could provide an ideal combination of strength and degradation, facilitating fracture fixation and healing while eliminating the need for implant removal surgery. Fixation plates and screws were machined from 99.9% pure magnesium and compared with titanium devices in a rabbit ulnar fracture model. Magnesium device degradation and the effect on fracture healing and bone formation were assessed after 4 weeks. Fracture healing with magnesium device fixation was compared with that of titanium devices using qualitative histologic analysis and quantitative histomorphometry. Micro-computed tomography showed device degradation after 4 weeks in vivo. In addition, 2-dimensional micro-computed tomography slices and histologic staining showed that magnesium degradation did not inhibit fracture healing or bone formation. Histomorphology showed no difference in bone-bridging fractures fixed with magnesium and titanium devices. Interestingly, abundant new bone was formed around magnesium devices, suggesting a connection between magnesium degradation and bone formation. Our results show potential for magnesium fixation devices in a loaded fracture environment. Furthermore, these results suggest that magnesium fixation devices may enhance fracture healing by encouraging localized new bone formation. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. The influence of distal screw length on the primary stability of volar plate osteosynthesis--a biomechanical study.

    PubMed

    Baumbach, Sebastian F; Synek, Alexander; Traxler, Hannes; Mutschler, Wolf; Pahr, Dieter; Chevalier, Yan

    2015-09-08

    Extensor tendon irritation is one of the most common complications following volar locking plate osteosynthesis (VLPO) for distal radius fractures. It is most likely caused by distal screws protruding the dorsal cortex. Shorter distal screws could avoid this, yet the influence of distal screw length on the primary stability in VLPO is unknown. The aim of this study was to compare 75 to 100% distal screw lengths in VLPO. A biomechanical study was conducted on 11 paired fresh-frozen radii. HRpQCT scans were performed to assess bone mineral density (BMD) and bone mineral content (BMC). The specimens were randomized pair-wise into two groups: 100% (group A) and 75% (group B) unicortical distal screw lengths. A validated fracture model for extra-articular distal radius fractures (AO-23 A3) was used. Polyaxial volar locking plates were mounted, and distal screws was inserted using a drill guide block. For group A, the distal screw tips were intended to be flush or just short of the dorsal cortex. In group B, a target screw length of 75% was calculated. The specimens were tested to failure using a displacement-controlled axial compression test. Primary biomechanical stability was assessed by stiffness, elastic limit, and maximum force as well as with residual tilt, which quantified plastic deformation. Nine specimens were tested successfully. BMD and BMC did not differ between the two groups. The mean distal screw length of group A was 21.7 ± 2.6 mm (range: 16 to 26 mm), for group B 16.9 ± 1.9 mm (range: 12 to 20 mm). Distal screws in group B were on average 5.6 ± 0.9 mm (range: 3 to 7 mm) shorter than measured. No significant differences were found for stiffness (706 ± 103 N/mm vs. 660 ± 124 N/mm), elastic limit (177 ± 25 N vs. 167 ± 36 N), maximum force (493 ± 139 N vs. 471 ± 149 N), or residual tilt (7.3° ± 0.7° vs. 7.1° ± 1.3°). The 75% distal screw length in VLPO provides similar primary stability to 100

  20. Volar fixed-angle plating of extra-articular distal radius fractures--a biomechanical analysis comparing threaded screws and smooth pegs.

    PubMed

    Weninger, Patrick; Dall'Ara, Enrico; Leixnering, Martin; Pezzei, Christoph; Hertz, Harald; Drobetz, Herwig; Redl, Heinz; Zysset, Philippe

    2010-11-01

    Distal radius fractures represent the most common fractures in adult individuals. Volar fixed-angle plating has become a popular modality for treating unstable distal radius fractures. Most of the plates allow insertion of either threaded locking screws or smooth locking pegs. To date, no biomechanical studies compare locking screws and pegs under axial and torsional loading. Ten Sawbones radii were used to simulate an AO/OTA A3 fracture. Volar fixed-angle plates (Aptus Radius 2.5, Medartis, Switzerland) with threaded locking screws (n = 5) or smooth locking pegs (n = 5) were used to fix the distal metaphyseal fragment. Each specimen was tested under axial compression and under torsional load with a servohydraulic testing machine. Qualitative parameters were recorded as well as axial and torsional stiffness, torsion strength, energy absorbed during monotonic loading and energy absorbed in one cycle. Axial stiffness was comparable between both groups (p = 0.818). If smooth pegs were used, a 17% reduction of torsional stiffness (p = 0.017) and a 12% reduction of minimum torque (p = 0.012) were recorded. A 12% reduction of energy absorbed (p = 0.013) during monotonic loading and unloading was recorded if smooth pegs were used. A 34% reduction of energy absorbed in one cycle (p < 0.007) was recorded if threaded screws were used. Sliding of the pegs out of the distal radius metaphyses of the synthetic bones was recorded at a mean torque of 3.80 Nm ± 0.19 Nm. No sliding was recorded if threaded screws were used. According to the results of this study using Sawbones, volar fixed-angle plates with threaded locking screws alone are mechanically superior to volar fixed-angle plates with smooth locking pegs alone under torsional loading.

  1. Automated Bone Screw Tightening to Adaptive Levels of Stripping Torque.

    PubMed

    Reynolds, Karen J; Mohtar, Aaron A; Cleek, Tammy M; Ryan, Melissa K; Hearn, Trevor C

    2017-06-01

    To use relationships between tightening parameters, related to bone quality, to develop an automated system that determines and controls the level of screw tightening. An algorithm relating current at head contact (IHC) to current at construct failure (Imax) was developed. The algorithm was used to trigger cessation of screw insertion at a predefined tightening level, in real time, between head contact and maximum current. The ability of the device to stop at the predefined level was assessed. The mean (±SD) current at which screw insertion ceased was calculated to be [51.47 ± 9.75% × (Imax - IHC)] + IHC, with no premature bone failures. A smart screwdriver was developed that uses the current from the motor driving the screw to predict the current at which the screw will strip the bone threads. The device was implemented and was able to achieve motor shut-off and cease tightening at a predefined threshold, with no premature bone failures.

  2. Proximal half angle of the screw thread is a critical design variable affecting the pull-out strength of cancellous bone screws.

    PubMed

    Wang, Yingxu; Mori, Ryuji; Ozoe, Nobuaki; Nakai, Takahisa; Uchio, Yuji

    2009-11-01

    Screws with strong pull-out strength have been sought for the treatment of cancellous bone. We hypothesized that an obliquely angled screw thread has advantages over conventional vertical thread with a minimal proximal half angle. Metal and bone screws were made of stainless steel and porcine cortical bone. Their proximal half angle was set at 0 degrees , 30 degrees , or 60 degrees . The screws were inserted into porcine cancellous bone. At 0 degrees , the thread faced the recipient bone vertically. Pullout tests at a rate of 30 mm/min (n=40, each screw type) and microcomputed tomography (n=6) were conducted. The pull-out strength of the screws was maximal at 30 degrees ; 348.8 (SD, 44.1)N with metal and 326.6 (39.4)N with bone. It was intermediate at 0 degrees ; 301.9 (35.9)N with metal and 278.2 (30.6)N with bone. It was minimal at 60 degrees; 126.5 (39.0)N with metal and 174.8 (29.7)N with bone. Cancellous bone was damaged between the threads at 30 degrees , while intact cancellous bone was preserved between the threads at 0 degrees. A proximal half angle of around 30 degrees is appropriate because the pullout force is applied to the recipient bone evenly. Commercial cancellous screws can be improved by changing the thread shape to minimize the damage to recipient bone.

  3. [Development of polyaxial locking plate screw system of sacroiliac joint].

    PubMed

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P < 0.05), but there was no significant difference between group B and group C (P > 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P < 0.05). The horizontal displacement on angle under the condition of 0-6 N·m torsional load in group B was bigger than that in group C, and the horizontal displacement on angle under the condition of 6-12 N·m torsional load in group B was less than

  4. Torsional stability of interference screws derived from bovine bone - a biomechanical study

    PubMed Central

    2010-01-01

    Background In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. Methods In the first part of the study we compared the torsional stability of self-made 8 mm Interference screws (BC) and a commercial 8 mm interference screw (Tutofix®). Furthermore, we compared the torsional strength of BC screws with different diameters. For screwing in, a hexagon head and an octagon head were tested. Maximum breaking torques in polymethyl methacrylate resin were recorded by means of an electronic torque screw driver. In the second part of the study the tibial part of a bone-patellar tendon-bone graft was fixed in porcine test specimens using an 8 mm BC screw and the maximum insertion torques were recorded. Each interference screw type was tested 5 times. Results There was no statistically significant difference between the different 8 mm interference screws (p = 0.121). Pairwise comparisons did not reveal statistically significant differences, either. It was demonstrated for the BC screws, that a larger screw diameter significantly leads to higher torsional stability (p = 9.779 × 10-5). Pairwise comparisons showed a significantly lower torsional stability for the 7 mm BC screw than for the 8 mm BC screw (p = 0.0079) and the 9 mm BC screw (p = 0.0079). Statistically significant differences between the 8 mm and the 9 mm BC screw could not be found (p = 0.15). During screwing into the tibial graft channel of the porcine specimens, insertion torques between 0.5 Nm and 3.2 Nm were recorded. In one case the hexagon head of a BC screw broke off during the last turn. Conclusions The BC screws show comparable torsional stability to Tutofix® interference screws. As expected the torsional strength of the screws increases significantly with the diameter. The safety

  5. Multidirectional volar fixed-angle plating using cancellous locking screws for distal radius fractures--evaluation of three screw configurations in an extra-articular fracture model.

    PubMed

    Weninger, Patrick; Dall'Ara, Enrico; Drobetz, Herwig; Nemec, Wolfgang; Figl, Markus; Redl, Heinz; Hertz, Harald; Zysset, Philippe

    2011-01-01

    Volar fixed-angle plating is a popular treatment for unstable distal radius fractures. Despite the availability of plating systems for treating distal radius fractures, little is known about the mechanical properties of multidirectional fixed-angle plates. The aim of this study was to compare the primary fixation stability of three possible screw configurations in a distal extra-articular fracture model using a multidirectional fixed-angle plate with metaphyseal cancellous screws distally. Eighteen Sawbones radii (Sawbones, Sweden, model# 1027) were used to simulate an extra-articular distal radius fracture according to AO/OTA 23 A3. Plates were fixed to the shaft with one non-locking screw in the oval hole and two locking screws as recommended by the manufacturer. Three groups (n = 6) were defined by screw configuration in the distal metaphyseal fragment: Group 1: distal row of screws only; Group 2: 2 rows of screws, parallel insertion; Group 3: 2 rows of screws, proximal screws inserted with 30° of inclination. Specimens underwent mechanical testing under axial compression within the elastic range and load controlled between 20 N and 200 N at a rate of 40 N/s. Axial stiffness and type of construct failure were recorded. There was no difference regarding axial stiffness between the three groups. In every specimen, failure of the Sawbone-implant-construct occurred as plastic bending of the volar titanium plate when the dorsal wedge was closed. Considering the limitations of the study, the recommendation to use two rows of screws or to place screws in the proximal metaphyseal row with inclination cannot be supported by our mechanical data.

  6. [Imaging analysis of jaw defects reparation with antigen-extracted porcine cancellous bone].

    PubMed

    Chen, Xufeng; Lu, Lihong; Feng, Zhiqiang; Yin, Zhongda; Lai, Renfa

    2017-12-01

    At present, most of the bone xenograft for clinical application comes from bovine. In recent years, many studies have been done on the clinical application of porcine xenograft bone. The goal of this study was to evaluate the effect of canine mandibular defects reparation with antigen-extracted porcine cancellous bone by imaging examination. Four dogs' bilateral mandibular defects were created, with one side repaired with autologous bone (set as control group) while the other side repaired with antigen-extracted porcine cancellous bone (set as experimental group). Titanium plates and titanium screws were used for fixation. Cone beam computed tomography (CBCT), computed tomography (CT), single-photon emission computed tomography (SPECT) were undertaken at week 12 and 24 postoperatively, and SPECT and CT images were fused. The results demonstrated that the remodeling of antigen-extracted porcine cancellous bone was slower than that of autologous bone, but it can still be used as scaffold for jaw defects. The results in this study provide a new choice for materials required for clinical reparation of jaw defects.

  7. Influence of abutment screw preload on stress distribution in marginal bone.

    PubMed

    Khraisat, Ameen

    2012-01-01

    Changes in an implant assembly after abutment connection might possibly cause deformation in the implant/abutment joint and even in the marginal bone. The aim of this study was to evaluate the influence of abutment screw preload through the implant collar on marginal bone stress without external load application. Models of three implant parts made of titanium (implant, abutment, and abutment screw) and cortical bone were built and positioned with computer-aided design software. Meshing and generation of boundary conditions, loads, and interactions were performed. Each part was meshed independently. The sole load applied to the model was a torque of 32 Ncm on the abutment screw about its axis of rotation. The implant collar was deformed axially after the screw was tightened (3 μm). This deformation resulted in 60 MPa of stress in the marginal bone. Moreover, pressure on the marginal bone in a radial direction was observed. It can be concluded that, without any external load application, abutment screw preload exerts stresses on the implant collar and the marginal bone. These findings should help guide the development of new implant/abutment joint designs that exert less stress on the marginal bone.

  8. Screw Loosening and Pelvic Canal Narrowing After Lateral Plating of Feline Ilial Fractures With Locking and Nonlocking Plates.

    PubMed

    Schmierer, Philipp A; Kircher, Patrick R; Hartnack, Sonja; Knell, Sebastian C

    2015-10-01

    To compare the frequency of complications, including screw loosening and pelvic canal narrowing, associated with dynamic compression plating, locking plating, and double locking plating of ilial fractures in cats. Historical cohort study. The radiographs and medical records of cats with pelvic fractures that were presented between 2004 and 2013 were reviewed. The cases were categorized based on the plate type and number as dynamic compression plate (DCP), single locking plate (LPS) and double locking plates (dLPS). The frequency of screw loosening was compared across categories using a Fisher's exact test. The change in pelvic alignment, described by the change in sacral index (postoperative sacral index-followup sacral index), was compared across plate categories using ANOVA. The frequency of screw loosening for DCP (5/10) was significantly higher than LPS (1/13) and dLPS (0/11) (P = .05, P = .012, respectively). There was no significant difference in the SI change across plate categories. The mean change in sacral index for DCP was -0.11 (95%CI -0.25 to 0.03), for LPS was 0.0007 (95%CI -0.07 to 0.08), and for dLPS was -0.01 (95%CI -0.04 to 0.02). None of the cats showed constipation postoperatively. Screw loosening occurred less often but the change in pelvic canal alignment was not significantly different in ilial fractures repaired with LPS or dLPS compared to ilial fractures repaired with DCP. Locking plating of ilial fractures in cats may offer advantages compared to nonlocking plating. © Copyright 2015 by The American College of Veterinary Surgeons.

  9. Mechanical evaluation of the SLM fabricated, stiffness-matched, mandibular bone fixation plates

    NASA Astrophysics Data System (ADS)

    Jahadakbar, Ahmadreza; Shayesteh Moghaddam, Narges; Amerinatanzi, Amirhesam; Dean, David; Elahinia, Mohammad

    2018-03-01

    The standard of the care for the treatment of mandibular segmental defects is the use of Ti-6Al-4V bone fixation plates and screws to immobilize the grafted bone and the host mandible. While Ti-6Al-4V bone fixation plates provide strong immobilization during the healing period, they may disturb the stress distribution in the repaired mandible. The highly stiff Ti-6Al-4V fixation carries a great portion of the load which was previously borne by the mandible, and stress shielding may occur on the surrounding cortical bone. Based on the bone remodeling theory, stress shielding causes bone resorption in the effected region and may eventually lead to the failure of the surgical reconstruction. To address this issue, we have developed a new generation of the patient-specific, porous NiTi bone fixation plates which benefit from stiffness-matching of the adjacent bone. Using the CT scan data of the patient's defective mandible, the geometry for the required bone fixation plates is designed and the stiffness of the surrounding regions is measured. By introducing specific level and type of porosity to the bone fixation plate, its stiffness can be tuned. Finite Element simulations has verified the reduced level of stress shielding on the reconstructed mandible, in case of using the proposed bone fixation plates. Selective Lase Sintering has been used for fabrication of the porous NiTi bone fixation plates with six different levels of stiffness. Finite element simulations, and mechanical tests have been done to verify the performance of the fabricated parts resulting from our design and fabrication method.

  10. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    PubMed

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P < 0.001) smaller than that of the screw fixation system. The maximal value of displacement (sum) in the plate-screw fixation system was 2.46 mm, which was lower than that in the screw fixation system (3.91 mm). The peak stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  11. Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws.

    PubMed

    Perren, S M; Linke, B; Schwieger, K; Wahl, D; Schneider, E

    2005-01-01

    Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.

  12. Role of Appositional Screw Fixation in Minimally Invasive Plate Osteosynthesis for Distal Tibial Fracture.

    PubMed

    Yang, Kyu-Hyun; Won, Yougun; Kang, Dong-Hyun; Oh, Jin-Cheol; Kim, Sung-Jun

    2015-09-01

    To determine the effect of interfragmentary appositional (gap-closing) screw fixation in minimally invasive plate osteosynthesis (MIPO) for distal tibial fractures on the clinical and radiologic results. Prospective nonrandomized study. Level I trauma center. Sixty patients who were diagnosed as distal metadiaphyseal oblique or spiral tibial fracture without displaced articular fragment. Thirty patients (group A) of the 60 patients were treated with MIPO without appositional screw fixation, and the other 30 (group B) were treated with the screw. Radiologic union, clinical union, clinical functional score [American Orthopaedic Foot and Ankle Society (AOFAS) score], and complications. The time for initial callus formation and radiologic union was significantly longer in group A than those in group B (76.8 vs. 58.0 days, P = 0.044; 409 vs. 258.7 days, P = 0.002, respectively). The rate of clinical union during 1 year was significantly higher in group B than in group A (P = 0.0063). Four nonunion patients in group A achieved bone union after placement of an additional bone graft. None of the patients in group B diagnosed with delayed union or nonunion (P < 0.001). None of the patients of both groups had malreduction, skin problems, or infection. Overall, the AOFAS score did not significantly differ between groups A and B (85.4 vs. 87.0, P = 0.43). The use of additional interfragmentary appositional screw fixation in distal tibia MIPO for the fixation of oblique or spiral fracture promoted callus formation and union rate compared with MIPO without appositional screw fixation. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. Bioactive ceramic coating of cancellous screws improves the osseointegration in the cancellous bone.

    PubMed

    Lee, Jae Hyup; Nam, Hwa; Ryu, Hyun-Seung; Seo, Jun-Hyuk; Chang, Bong-Soon; Lee, Choon-Ki

    2011-05-01

    A number of methods for coating implants with bioactive ceramics have been reported to improve osseointegration in bone, but the effects of bioactive ceramic coatings on the osseointegration of cancellous screws are not known. Accordingly, biomechanical and histomorphometric analyses of the bone-screw interface of uncoated cancellous screws and cancellous screws coated with four different bioactive ceramics were performed. After coating titanium alloy cancellous screws with calcium pyrophosphate (CPP), CaO-SiO(2)-B(2)O(3) glass-ceramics (CSG), apatite-wollastonite 1:3 glass-ceramics (W3G), and CaO-SiO(2)-P(2)O(5)-B(2)O(3) glass-ceramics (BGS-7) using an enameling method, the coated and the uncoated screws were inserted into the proximal tibia and distal femur metaphysis of seven male mongrel dogs. The torque values of the screws were measured at the time of insertion and at removal after 8 weeks. The bone-screw contact ratio was analyzed by histomorphometry. There was no significant difference in the insertion torque between the uncoated and coated screws. The torque values of the CPP and BGS-7 groups measured at removal after 8 weeks were significantly higher than those of the uncoated group. Moreover, the values of the CPP and BGS-7 groups were significantly higher than the insertion torques. The fraction of bone-screw interface measured from the undecalcified histological slide showed that the CPP, W3G, and BGS-7 groups had significantly higher torque values in the cortical bone area than the uncoated group, and the CPP and BGS-7 groups had significantly higher torque values in the cancellous bone area than the uncoated group. In conclusion, a cancellous screw coated with CPP and BGS-7 ceramic bonds directly to cancellous bone to improve the bone-implant osseointegration. This may broaden the indications for cancellous screws by clarifying their contribution to improving osseointegration, even in the cancellous bone area.

  14. Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?

    PubMed Central

    Zderic, I.; Grechenig, S.; Richards, R. G.; Schmitz, P.; Gueorguiev, B.

    2017-01-01

    Objectives Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. Materials and Methods A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm3 (standard deviation (sd) 52). The anterior pelvic ring fracture was fixed with either one 7.3 mm cannulated screw (Group 1) or two 3.5 mm pelvic cortex screws (Group 2). Progressively increasing cyclic axial loading was applied through the acetabulum. Relative movements in terms of interfragmentary displacement and gap angle at the fracture site were evaluated by means of optical movement tracking. The Wilcoxon signed-rank test was applied to identify significant differences between the groups Results Initial axial construct stiffness was not significantly different between the groups (p = 0.463). Interfragmentary displacement and gap angle at the fracture site were also not statistically significantly different between the groups throughout the evaluated cycles (p ⩾ 0.249). Similarly, cycles to failure were not statistically different between Group 1 (8438, sd 6968) and Group 2 (10 213, sd 10 334), p = 0.379. Failure mode in both groups was characterised by screw cutting through the cancellous bone. Conclusion From a biomechanical point of view, pubic ramus stabilisation with either one large or two small fragment screw osteosynthesis is comparable in osteoporotic bone. However, the two-screw fixation technique is less demanding as the smaller screws deflect at the cortical margins. Cite this article: Y. P. Acklin, I. Zderic, S. Grechenig, R. G. Richards, P

  15. Secure Screw Placement in Management of Acetabular Fractures Using the Suprapectineal Quadrilateral Buttress Plate.

    PubMed

    Egli, R J; Keel, M J B; Cullmann, J L; Bastian, J D

    2017-01-01

    Acetabular fractures involving predominantly the anterior column associated with a disruption of the quadrilateral surface can be treated with instrumentation implementing the stabilization of the quadrilateral surface. The recently introduced suprapectineal quadrilateral buttress plate is specifically designed to prevent secondary medial subluxation of the femoral head, especially in elderly patients with reduced ability for partial weight bearing. Whereas there are guidelines available for safe screw fixation for the anterior and posterior columns, there might be a concern for intra-articular placement of screws placed through the infrapectineal part of the quadrilateral buttress plate. Within this report we analyzed retrospectively screw placement in 30 plates in postoperative CT scans using algorithms for metal artifact reduction. None of the screws of the buttress plate penetrated the hip joint. We describe the placement, length, and spatial orientation of the screws used for fracture fixation and suggest that the use of intraoperative image intensifiers with a combined inlet-obturator view of 30-45° best projects the screws and the hip joint. Preoperative knowledge of approximate screw placement and information for accurate intraoperative imaging may contribute to safe acetabular fracture fixation and may reduce operating time and limit radiation exposure to the patient and the personnel. This trial is registered with KEK-BE: 266/2014.

  16. Mechanical stress in plates for bridging reconstruction mandibular defects and purposes of double plate reinforcement.

    PubMed

    Hoefert, Sebastian; Taier, Roberto

    2018-05-01

    To evaluate the biomechanical performance of a commercially available bridging plate (2.4) as well as screws and bone simulating the reconstruction of hemimandibular defects and to indicate alternatives of reinforcement to prevent plate fractures either by strength or fatigue. Two common hemimandibular defects are investigated using computed finite element analysis (FEA) approach. Simplified and refined computational models are developed for the geometry of the screw. Conditions of non-locking and locking plate-screw interfaces are considered. Static loads of 120 N are applied. Von Mises stresses and fatigue are calculated. As reinforcement, a second complete or partial plate is placed onto the original plate. Results demonstrate that reconstruction plates are often subjected to excessive stress that may lead to fracture either by strength or by fatigue. An attached complete or partial second plate is able to reduce stress in the plate, in screws and bone so that stress remains below the allowable limit of the materials. A simplified technique of attaching a whole or sectioned second plate onto the original plate can reduce the stress calculated and may reduce the frequency of plate fractures for the patient's comfort, security and financial savings. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Mechanical and histological analysis of bone-pedicle screw interface in vivo: titanium versus stainless steel.

    PubMed

    Sun, C; Huang, G; Christensen, F B; Dalstra, M; Overgaard, S; Bünger, C

    1999-05-01

    To investigate the differences in bone interface between titanium and stainless steel pedicle screws in the lumbar spine. Eighteen adult mini-pigs that underwent total laminectomy, posterolateral spinal fusion (L4-L5) were randomly selected to receive stainless steel (9) or titanium pedicle screw devices (9). In both groups, the devices were CCD (Sofamore Danek) type with the same size and shape. The postoperative observation time was 3 months. Screws from L4 were harvested along their long axis of pedicle for histomorphometric study. Bone-screw interface and bone volume from thread were examined using linear intercept techniques. Mechanical testing (torsional test and pull-out test) was performed on the screws from L5. The titanium screw group had a significantly higher maximum torque (P < 0.05) and angle related stiffness (P < 0.05) measured by torsional test. In the pull-out tests, no differences were found between the two groups in relation to the maximum load, stiffness and energy to failure. Direct bone contact with the screw in percentage was 29.4% for stainless steel and 43.8% for titanium (P < 0.05). No differences in the bone purchase between the vertebral body part and pedicle part were found. Pedicle screws made of titanium have a better bone-screw interface binding than screws made of stainless steel. Torsional tests are more informative for bone-screw interface study. Pull-out tests seem less valuable when comparing bone purchase of screws made from different materials.

  18. Dorsal Plating of Unstable Scaphoid Fractures and Nonunions.

    PubMed

    Bain, Gregory I; Turow, Arthur; Phadnis, Joideep

    2015-09-01

    Achieving stable fixation of displaced acute and chronic nonunited scaphoid fractures continues to be a challenge for the treating surgeon. The threaded compression screw has been the mainstay of treatment of these fractures for the last 3 decades; however, persistent nonunion after screw fixation has prompted development of new techniques. Recent results of volar buttress plating have been promising. We describe a novel technique of dorsal scaphoid plating. In contrast to volar plating, the dorsal plate is biomechanically more favorable as it utilizes the tension side of the scaphoid bone for dynamic compression. Dorsal scaphoid plating provides a more stable construct than the traditional Herbert screw and mitigates the need for vascular or corticocancellous bone grafting in most cases.

  19. Optimal area of lateral mass mini-screws implanted in plated cervical laminoplasty: a radiography anatomy study.

    PubMed

    Chen, Hua; Li, Huibo; Deng, Yuxiao; Rong, Xin; Gong, Quan; Li, Tao; Song, Yueming; Liu, Hao

    2017-04-01

    Lateral mass mini-screws used in plated cervical laminoplasty might penetrate into facet joints. The objective is to observe this complication incidence and to identify the optimal areas for 5- and 7-mm-long mini-screws to implant on lateral mass. 47 patients who underwent plated cervical laminoplasty were included. The optimal area for mini-screws implanting was set according to pre-operative 3D CT reconstruction data. Then, each posterior-lateral mass surface was divided into three regions: 7-mm region, 5-mm region, and dangerous area. The mini-screw implanted region was recorded. Post-operative CT images were used to identify whether the mini-screws penetrated into facet joints. 235 mini-plates and 470 lateral mass mini-screws were used in the study. 117 (24.9%) mini-screws penetrated 88 (37.4%) facet joints. The 5-mm-long mini-screw optimal area occupied the upper 72, 65, 65, 64, and 65 % area of the posterior-lateral mass surface for C3-7, while the 7-mm-long mini-screw optimal area encompassed the upper 54, 39, 40, 33, and 32 %. Only 7-mm-long mini-screws were used to fix the plate to the lateral mass. 4 of 240 mini-screws in 7-mm region, 67 of the 179 mini-screws in 5-mm region, and 46 of the 51 mini-screws in dangerous region penetrated into the facet joint. The differences in the rate of facet joint penetration related to region were statistically significant (P < 0.001). The facet joint destruction by mini-screws was not a rare complication in plated cervical laminoplasty. The optimal areas we proposed may help guide the mini-screw implantation positions.

  20. Numerical analysis of standard and modified osteosynthesis in long bone fractures treatment.

    PubMed

    Sisljagić, Vladimir; Jovanović, Savo; Mrcela, Tomislav; Radić, Radivoje; Selthofer, Robert; Mrcela, Milanka

    2010-03-01

    The fundamental problem in osteoporotic fracture treatment is significant decrease in bone mass and bone tissue density resulting in decreased firmness and elasticity of osteoporotic bone. Application of standard implants and standard surgical techniques in osteoporotic bone fracture treatment makes it almost impossible to achieve stable osteosynthesis sufficient for early mobility, verticalization and load. Taking into account the form and the size of the contact surface as well as distribution of forces between the osteosynthetic materials and the bone tissue numerical analysis showed advantages of modified osteosynthesis with bone cement filling in the screw bed. The applied numerical model consisted of three sub-models: 3D model from solid elements, 3D cross section of the contact between the plate and the bone and the part of 3D cross section of the screw head and body. We have reached the conclusion that modified osteosynthesis with bone cement resulted in weaker strain in the part of the plate above the fracture fissure, more even strain on the screws, plate and bone, more even strain distribution along all the screws' bodies, significantly greater strain in the part of the screw head opposite to the fracture fissure, firm connection of the screw head and neck and the plate hole with the whole plate and more even bone strain around the screw.

  1. Biomechanical analysis of a new carbon fiber/flax/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate.

    PubMed

    Bagheri, Zahra S; Tavakkoli Avval, Pouria; Bougherara, Habiba; Aziz, Mina S R; Schemitsch, Emil H; Zdero, Radovan

    2014-09-01

    MPa for metal-plated femurs at the vicinity of nearest screw just proximal to fracture (stage 3), 21 MPa for composite and 24 MPa for metal-plated femurs at the vicinity of screw farthest away distally from fracture (stage 4). These results confirm that the new CF/Flax/Epoxy material could be a potential candidate for bone fracture plate applications as it can simultaneously provide similar mechanical stiffness and lower stress shielding (i.e., higher bone stress) compared to a standard clinical metal bone plate.

  2. Biomechanical testing of locking and nonlocking plates in the canine scapula.

    PubMed

    Acquaviva, Anthony E; Miller, Emily I; Eisenmann, David J; Stone, Rick T; Kraus, Karl H

    2012-01-01

    Locking plates have been shown to offer improved fixation in fractures involving either osteoporotic bone or bone with lesser screw pullout strength, such as thin and flat bones. Fractures of the scapular body are one type of fracture where the screw pullout strength using conventional plate fixation may not be sufficient to overcome physiologic forces. The purpose of this study was to compare the pullout strengths of locking plates to conventional nonlocking plates in the canine scapula. A 2.7 mm string of pearls plate (SOP) and a 2.7 mm limited contact dynamic compression plate (LC-DCP) were applied with similar divergent screws to the supraspinatus fossa of the scapula. Forces perpendicular to the plates were applied and both the loads at failure and modes of failure were recorded. No differences were noted in loads at failure between the two plating systems. Although the modes of failure were not significantly different, the SOP constructs tended to fail more often by bone slicing and coring, whereas the LC-DCP constructs failed primarily by screw stripping. Neither of the plate systems used in this study demonstrated a distinct mechanical advantage. The application and limitations of locking plate systems in various clinical situations require further study.

  3. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur.

    PubMed

    Heyland, Mark; Duda, Georg N; Haas, Norbert P; Trepczynski, Adam; Döbele, Stefan; Höntzsch, Dankward; Schaser, Klaus-Dieter; Märdian, Sven

    2015-10-01

    Extent and orientation of interfragmentary movement (IFM) are crucially affecting course and quality of fracture healing. The effect of different configurations for implant fixation on successful fracture healing remain unclear. We hypothesize that screw type and configuration of locking plate fixation profoundly influences stiffness and IFM for a given load in a distal femur fracture model. Simple analytical models are presented to elucidate the influence of fixation configuration on construct stiffness. Models were refined with a consistent single-patient-data-set to create finite-element femur models. Locking plate fixation of a distal femoral 10mm-osteotomy (comminution model) was fitted with rigid locking screws (rLS) or semi-rigid locking screws (sLS). Systematic variations of screw placements in the proximal fragment were tested. IFM was quantitatively assessed and compared for different screw placements and screw types. Different screw allocations significantly affect IFM in a locking plate construct. LS placement of the first screw proximal to the fracture (plate working length, PWL) has a significant effect on axial IFM (p < 0.001). Replacing rLS with sLS caused an increase (p < 0.001) of IFM under the plate (cis-cortex) between +8.4% and +28.1% for the tested configurations but remained constant medially (<1.1%, trans-cortex). Resultant shear movements markedly increased at fracture level (p < 0.001) to the extent that plate working length increased. The ratio of shear/axial IFM was found to enhance for longer PWL. sLS versus rLS lead to significantly smaller ratios of shear/axial IFM at the cis-cortex for PWL of ≥ 62 mm (p ≤ 0.003). Mechanical frame conditions can be significantly influenced by type and placement of the screws in locking plate osteosynthesis of the distal femur. By varying plate working length stiffness and IFM are modulated. Moderate axial and concomitantly low shear IFM could not be achieved through changes in screw placement

  4. The self adapting washer for lag screw fixation of mandibular fractures: finite element analysis and preclinical evaluation.

    PubMed

    Terheyden, H; Mühlendyck, C; Feldmann, H; Ludwig, K; Härle, F

    1999-02-01

    Besides rigid fixation, lag screws have distinct advantages compared with plates in appropriate indications in mandibular fractures. However, in current lag screw systems, the relatively small area of the screw head has to transfer the tensile force which can exceed 1000 N in the symphysis, to the thin cortical bone plate. Countersinking, which is obligatory in most systems, will weaken the cortical plate. Finite element analysis (FEA) revealed that load in this situation can exceed the normal tensile strength of metal and bone. Consequently, a new washer was constructed which both increased the supporting surface and did not require countersinking. The washer is self adapting (SAW) to the cortical plate in a defined position, forming a ball and socket joint with the screw head. Using the FEA model, a ten-fold reduction in load on bone and metal was observed with the new washer. In a miniature pig mandibular symphysis fracture model, the clinical applicability and a favourable histological reaction were demonstrated, compared with conventional lag screw designs.

  5. Micro-CT evaluation and histological analysis of screw-bone interface of expansive pedicle screw in osteoporotic sheep.

    PubMed

    Wan, Shi-yong; Lei, Wei; Wu, Zi-xiang; Lv, Rong; Wang, Jun; Fu, Suo-chao; Li, Bo; Zhan, Ce

    2008-04-01

    To investigate the properties of screw-bone interface of expansive pedicle screw (EPS) in osteoporotic sheep by micro-CT and histological observation. Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment. After EPS insertion in each femoral condyle, the sheep were randomly divided into two groups: 3 sheep were bred for 3 months (Group A), while the other 3 were bred for 6 months (Group B). After the animals being killed, the femoral condyles with EPS were obtained, which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter. The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within the spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional (3-D) parameters, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp), were significantly better in expansive sections than non-expansive sections (P less than 0.05). Histologically, newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones, as well as the bones at the bone-screw interface, closely contacted with the EPS and constructed four compartments. The findings of the current study, based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.

  6. Fixation of mandibular fractures with biodegradable plates and screws.

    PubMed

    Yerit, Kaan C; Enislidis, Georg; Schopper, Christian; Turhani, Dritan; Wanschitz, Felix; Wagner, Arne; Watzinger, Franz; Ewers, Rolf

    2002-09-01

    Little data exist regarding the use of biodegradable plates and screws for the internal fixation of human mandibular fractures. The purpose of this study was to evaluate the stability of biodegradable, self-reinforced poly-L-lactide plates and screws for the internal fixation of fractures of the human mandible. Twenty-two individuals (14 male, 8 female; average age, 26.3 years) with a variety of fracture patterns of the mandible underwent management with a biodegradable fixation system. After surgery, maxillomandibular fixation was applied in 3 cases. Images (panoramic radiograph, computed tomographic scan) were taken immediately after surgery and at the 4-week, 8-week, 12-week, and 24-week intervals. The follow-up period averaged 49.1 weeks (range, 22 to 78 weeks). Mucosal dehiscences over the resorbable devices were present in 2 patients. In 1 of these 2 cases, the material had to be replaced with titanium plates. Mucosal healing and consolidation of the fracture were normal in all other patients. Self-reinforced biodegradable osteosynthesis materials provide a reliable and sufficient alternative to conventional titanium plate systems.

  7. Biomechanical competence of six different bone screws for reconstructive surgery in three different transplants: Fibular, iliac crest, scapular and artificial bone.

    PubMed

    Pietsch, Arnold P; Raith, Stefan; Ode, Jan-Eric; Teichmann, Jan; Lethaus, Bernd; Möhlhenrich, Stephan C; Hölzle, Frank; Duda, Georg N; Steiner, Timm

    2016-06-01

    The goal of this study was to determine a combination of screw and transplantation type that offers optimal primary stability for reconstructive surgery. Fibular, iliac crest, and scapular transplants were tested along with artificial bone substrate. Six different kinds of bone screws (Medartis(©)) were compared, each type utilized with one of six specimens from human transplants (n = 6). Controlled screw-in-tests were performed and the required torque was protocolled. Subsequently, pull-out-tests were executed to determine the retention forces. The artificial bone substitute material showed significantly higher retention forces than real bone samples. The self-drilling screws achieved the significantly highest retention values in the synthetic bone substitute material. Cancellous screws achieved the highest retention in the fibular transplants, while self-drilling and cancellous screws demonstrated better retention than cortical screws in the iliac crest. In the scapular graft, no significant differences were found between the screw types. In comparison to the human transplant types, the cortical screws showed the significantly highest values in the fibula and the lowest values in the iliac crest. The best retention was found in the combination of cancellous screws with fibular graft (514.8 N + -252.3 N). For the flat bones (i.e., scapular and illiac crest) we recommend the cancellous screws. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. ACL reconstruction using bone-patella tendon-bone autograft: press-fit technique vs. interference screw fixation.

    PubMed

    Sarzaeem, M M; Najafi, F; Razi, M; Najafi, M A

    2014-07-01

    The gold standard in ACL reconstructions has been the bone-patellar tendon-bone autograft fixed with interference screws. This prospective, randomized clinical trial aimed to compare two methods of fixation for BPTB grafts: press-fit fixation vs. interference screw, over a 12-month follow-up interval. 158 patients with an average age of 29.8 years, between 2011 and 2012, were treated for torn ACL. 82 patients underwent reconstruction with BPTB autograft with a press fit fixation technique, and in 76 cases an interference screw was used. At the time of final follow-up, 71 patients in press-fit group and 65 patients in interference screw group were evaluated in terms of return to pre-injury activity level, pain, knee stability, range of motion, IKDC score and complications. At 12-month follow-up, 59 (83 %) and 55 (85 %) in press-fit and screw group, respectively had good-to-excellent IKDC score (p > 0.05). The mean laxity assessed using a KT-1000 arthrometer improved to 2.7 and 2.5 mm in press-fit and screw group, respectively. Regarding Lachman and pivot shift test, there was a statistically significant improvement in the integrity of the ACL in both the groups, but no significant differences was noted between groups. There were no significant differences in terms of femur circumference difference, effusion, knee range of motion, pain and complications. The press-fit technique is an efficient procedure. Its outcome was comparable with the interference screw group. Furthermore it has unlimited bone-to-bone healing, no need for removal of hardware, ease for revision and cost effectiveness.

  9. An alternative method in mandibular fracture treatment: bone graft use instead of a plate.

    PubMed

    Alagöz, Murat Sahin; Uysal, Ahmet Cagri; Sensoz, Omer

    2008-03-01

    In the treatment of the mandibular fractures, one of the main principles is to use the least amount of foreign material. We present an alternative technique that the bone grafts harvested from the fracture borders or from the iliac crest were used instead of plates and the fixation was done with screws. In the study including 24 mandible fractures, the bone grafts harvested from the fracture borders were used in the 10 favorable fractures and the bone grafts harvested from the iliac crest were used in the 14 unfavorable fractures. In the combined mandible fractures, four fractures were fixated with titanium plates and the other side with the bone graft. The patients, who were followed up for 12 to 20 months, were evaluated with macroscopic occlusion, panoramic graphs, and three-dimensional computerized tomographs. The advantage of this technique of fixation with the autogenous tissue is reduced infection rates and reduced operation costs. In the pediatric patients, the second session operation of plate removal is not necessary.

  10. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?

    PubMed

    Shah, S; Kim, S Y R; Dubov, A; Schemitsch, E H; Bougherara, H; Zdero, R

    2011-09-01

    Femoral shaft fractures after total hip arthroplasty (THA) remain a serious problem, since there is no optimal surgical repair method. Virtually all studies that examined surgical repair methods have done so clinically or experimentally. The present study assessed injury patterns computationally by developing three-dimensional (3D) finite element (FE) models that were validated experimentally. The investigation evaluated three different constructs for the fixation of Vancouver B1 periprosthetic femoral shaft fractures following THA. Experimentally, three bone plate repair methods were applied to a synthetic femur with a 5 mm fracture gap near the tip of a total hip implant. Repair methods were identical distal to the fracture gap, but used cables only (construct A), screws only (construct B), or cables plus screws (construct C) proximal to the fracture gap. Specimens were oriented in 15 degrees adduction to simulate the single-legged stance phase of walking, subjected to 1000 N of axial force, and instrumented with strain gauges. Computationally, a linearly elastic and isotropic 3D FE model was developed to mimic experiments. Results showed excellent agreement between experimental and FE strains, yielding a Pearson linearity coefficient, R2, of 0.92 and a slope for the line of best data fit of 1.06. FE-computed axial stiffnesses were 768 N/mm (construct A), 1023 N/mm (construct B), and 1102 N/mm (construct C). FE surfaces stress maps for cortical bone showed Von Mises stresses, excluding peaks, of 0-8 MPa (construct A), 0-15 MPa (construct B), and 0-20 MPa (construct C). Cables absorbed the majority of load, followed by the plates and then the screws. Construct A yielded peak stress at one of the empty holes in the plate. Constructs B and C had similar bone stress patterns, and can achieve optimal fixation.

  11. The Improvement of Bone-Tendon Fixation by Porous Titanium Interference Screw: A Rabbit Animal Model.

    PubMed

    Tsai, Pei-I; Chen, Chih-Yu; Huang, Shu-Wei; Yang, Kuo-Yi; Lin, Tzu-Hung; Chen, San-Yuan; Sun, Jui-Sheng

    2018-05-04

    The interference screw is a widely used fixation device in the anterior cruciate ligament (ACL) reconstruction surgeries. Despite the generally satisfactory results, problems of using interference screws were reported. By using additive manufacturing (AM) technology, we developed an innovative titanium alloy (Ti 6 Al 4 V) interference screw with rough surface and inter-connected porous structure designs to improve the bone-tendon fixation. An innovative Ti 6 Al 4 V interference screws were manufactured by AM technology. In vitro mechanical tests were performed to validate its mechanical properties. Twenty-seven New Zealand white rabbits were randomly divided into control and AM screw groups for biomechanical analyses and histological analysis at 4, 8 and 12 weeks postoperatively; while micro-CT analysis was performed at 12 weeks postoperatively. The biomechanical tests showed that the ultimate failure load in the AM interference screw group was significantly higher than that in the control group at all tested periods. These results were also compatible with the findings of micro-CT and histological analyses. In micro-CT analysis, the bone-screw gap was larger in the control group; while for the additive manufactured screw, the screw and bone growth was in close contact. In histological study, the bone-screw gaps were wider in the control group and were almost invisible in the AM screw group. The innovative AM interference screws with surface roughness and inter-connected porous architectures demonstrated better bone-tendon-implant integration, and resulted in stronger biomechanical characteristics when compared to traditional screws. These advantages can be transferred to future interference screw designs to improve their clinical performance. The AM interference screw could improve graft fixation and eventually result in better biomechanical performance of the bone-tendon-screw construct. The innovative AM interference screws can be transferred to future

  12. Effect of screw torque level on cortical bone pullout strength.

    PubMed

    Cleek, Tammy M; Reynolds, Karen J; Hearn, Trevor C

    2007-02-01

    The objectives of this study were 2-fold: (1) to perform detailed analysis of cortical screw tightening stiffness during automated insertion, and (2) to determine the effect of 3 torque levels on the holding strength of the bone surrounding the screw threads as assessed by screw pullout. Ten pairs of ovine tibiae were used with 3 test sites spaced 20 mm apart centered along the shaft. One side of each pair was used for measuring ultimate failure torque (Tmax). These Tmax and bone-density values were used to predict Tmax at contralateral tibia sites. Screws were inserted and tightened to 50%, 70%, and 90% of predicted Tmax at the contralateral sites to encompass the average clinical level of torque (86% Tmax). Pullout tests were performed and maximum force values were normalized by cortical thickness. Torque to failure tests indicated tightening to 86% Tmax occurs after yield and leads to an average 51% loss in stiffness. Normalized pullout strength for screws tightened to 50% Tmax, 70% Tmax, and 90% Tmax were 2525 +/- 244, 2707 +/- 280, and 2344 +/- 346 N, respectively, with a significant difference between 70% Tmax and 90% Tmax groups (P < 0.05). Within the limitations of our study involving the testing of 1 type of screw purchase in ovine tibiae, results demonstrate that clinical levels of lag screw tightening (86% Tmax) are past the yield point of bone. Tightening to these high torque levels can cause damage leading to compromised holding strength. Further research is still required to establish the appropriate level of torque required for achieving optimal fracture fixation and healing.

  13. Variability of the pullout strength of cancellous bone screws with cement augmentation.

    PubMed

    Procter, P; Bennani, P; Brown, C J; Arnoldi, J; Pioletti, D P; Larsson, S

    2015-06-01

    Orthopaedic surgeons often face clinical situations where improved screw holding power in cancellous bone is needed. Injectable calcium phosphate cements are one option to enhance fixation. Paired screw pullout tests were undertaken in which human cadaver bone was augmented with calcium phosphate cement. A finite element model was used to investigate sensitivity to screw positional placement. Statistical analysis of the data concluded that the pullout strength was generally increased by cement augmentation in the in vitro human cadaver tests. However, when comparing the individual paired samples there were surprising results with lower strength than anticipated after augmentation, in apparent contradiction to the generally expected conclusion. Investigation using the finite element model showed that these strength reductions could be accounted for by small screw positional changes. A change of 0.5mm might result in predicted pullout force changes of up to 28%. Small changes in screw position might lead to significant changes in pullout strength sufficient to explain the lower than expected individual pullout values in augmented cancellous bone. Consequently whilst the addition of cement at a position of low strength would increase the pullout strength at that point, it might not reach the pullout strength of the un-augmented paired test site. However, the overall effect of cement augmentation produces a significant improvement at whatever point in the bone the screw is placed. The use of polymeric bone-substitute materials for tests may not reveal the natural variation encountered in tests using real bone structures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Pullout strength of cancellous screws in human femoral heads depends on applied insertion torque, trabecular bone microarchitecture and areal bone mineral density.

    PubMed

    Ab-Lazid, Rosidah; Perilli, Egon; Ryan, Melissa K; Costi, John J; Reynolds, Karen J

    2014-12-01

    For cancellous bone screws, the respective roles of the applied insertion torque (TInsert) and of the quality of the host bone (microarchitecture, areal bone mineral density (aBMD)), in contributing to the mechanical holding strength of the bone-screw construct (FPullout), are still unclear. During orthopaedic surgery screws are tightened, typically manually, until adequate compression is attained, depending on surgeons' manual feel. This corresponds to a subjective insertion torque control, and can lead to variable levels of tightening, including screw stripping. The aim of this study, performed on cancellous screws inserted in human femoral heads, was to investigate which, among the measurements of aBMD, bone microarchitecture, and the applied TInsert, has the strongest correlation with FPullout. Forty six femoral heads were obtained, over which microarchitecture and aBMD were evaluated using micro-computed tomography and dual X-ray absorptiometry. Using an automated micro-mechanical test device, a cancellous screw was inserted in the femoral heads at TInsert set to 55% to 99% of the predicted stripping torque beyond screw head contact, after which FPullout was measured. FPullout exhibited strongest correlations with TInsert (R=0.88, p<0.001), followed by structure model index (SMI, R=-0.81, p<0.001), bone volume fraction (BV/TV, R=0.73, p<0.001) and aBMD (R=0.66, p<0.01). Combinations of TInsert with microarchitectural parameters and/or aBMD did not improve the prediction of FPullout. These results indicate that, for cancellous screws, FPullout depends most strongly on the applied TInsert, followed by microarchitecture and aBMD of the host bone. In trabecular bone, screw tightening increases the holding strength of the screw-bone construct. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. [The biomechanics of screws, cerclage wire and cerclage cable].

    PubMed

    Schröder, C; Woiczinski, M; Utzschneider, S; Kraxenberger, M; Weber, P; Jansson, V

    2013-05-01

    In contrast to fracture fixation, when performing an osteotomy the surgeon is able to plan preoperatively. The resulting fixation and compression of the bone fragments are the most important points. A stable osteosynthesis should prevent dislocation of bone fragments and improve bone healing. Beside plates, cerclages can be used for tension band or diaphysis bone fixation. Moreover, cortical or cancellous screws can be used for osteotomy fixation. This work describes biomechanical principles for fixation after an osteotomy with cerclages and cortical or cancellous screws. It also summarizes the materials and geometries used, as well as their influence on the stability of the osteosynthesis.

  16. An in vitro biomechanical comparison of hydroxyapatite coated and uncoated ao cortical bone screws for a limited contact: dynamic compression plate fixation of osteotomized equine 3rd metacarpal bones.

    PubMed

    Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F

    2015-02-01

    To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA

  17. Pullout strength of monocortical and bicortical screws in metaphyseal and diaphyseal regions of the canine humerus.

    PubMed

    Vaughn, Denty Paul; Syrcle, Jason Alan; Ball, John E; Elder, Steven H; Gambino, Jennifer Michele; Griffin, Russell L; McLaughlin, Ronald M

    2016-11-23

    Monocortical screws are commonly employed in locking plate fixation, but specific recommendations for their placement are lacking and use of short monocortical screws in metaphyseal bone may be contraindicated. Objectives of this study were to evaluate axial pullout strength of two different lengths of monocortical screws placed in various regions of the canine humerus compared to bicortical screws, and to derive cortical thickness and bone density values for those regions using quantitative computed tomography analysis (QCT). The QCT analysis was performed on 36 cadaveric canine humeri for six regions of interest (ROI). A bicortical, short monocortical, or 50% transcortical 3.5 mm screw was implanted in each ROI and axial pullout testing was performed. Bicortical screws were stronger than monocortical screws in all ROI except the lateral epicondylar crest. Short monocortical metaphyseal screws were weaker than those placed in other regions. The 50% transcortical screws were stronger than the short monocortical screws in the condyle. A linear relationship between screw length and pullout strength was observed. Cortical thickness and bone density measurements were obtained from multiple regions of the canine humerus using QCT. Use of short monocortical screws may contribute to failure of locking plate fixation of humeral fractures, especially when placed in the condyle. When bicortical screw placement is not possible, maximizing monocortical screw length may optimize fixation stability for distal humeral fractures.

  18. Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures.

    PubMed

    Ni, Ming; Wong, Duo Wai-Chi; Mei, Jiong; Niu, Wenxin; Zhang, Ming

    2016-09-01

    The locking plate and percutaneous crossing metallic screws and crossing absorbable screws have been used clinically to treat intra-articular calcaneal fractures, but little is known about the biomechanical differences between them. This study compared the biomechanical stability of calcaneal fractures fixed using a locking plate and crossing screws. Three-dimensional finite-element models of intact and fractured calcanei were developed based on the CT images of a cadaveric sample. Surgeries were simulated on models of Sanders type III calcaneal fractures to produce accurate postoperative models fixed by the three implants. A vertical force was applied to the superior surface of the subtalar joint to simulate the stance phase of a walking gait. This model was validated by an in vitro experiment using the same calcaneal sample. The intact calcaneus showed greater stiffness than the fixation models. Of the three fixations, the locking plate produced the greatest stiffness and the highest von Mises stress peak. The micromotion of the fracture fixated with the locking plate was similar to that of the fracture fixated with the metallic screws but smaller than that fixated with the absorbable screws. Fixation with both plate and crossing screws can be used to treat intra-articular calcaneal fractures. In general, fixation with crossing metallic screws is preferable because it provides sufficient stability with less stress shielding.

  19. Optimising implant anchorage (augmentation) during fixation of osteoporotic fractures: is there a role for bone-graft substitutes?

    PubMed

    Larsson, Sune; Procter, Philip

    2011-09-01

    When stabilising a fracture the contact between the screw and the surrounding bone is crucial for mechanical strength. Through development of screws with new thread designs, as well as optimisation of other properties, improved screw purchase has been gained. Other alternatives to improve screw fixation in osteoporotic bone, as well as normal bone if needed, includes the use of various coatings on the screw that will induce a bonding between the implant surface and the bone implant, as well as application of drugs such as bisphosphonates locally in the screw hole to induce improved screw anchorage through their anticatabolic effect on the bone tissue. As failure of internal fixation of fractures in osteoporotic bone typically occurs through breakage of the bone that surrounds the implant, rather than the implant itself, an alternative strategy in osteoporotic bone can include augmentation of the bone around the screw. This is useful when screws alone are being used for fixation, as it will increase pull-out resistance, but also when conventional plates and screws are used. In angularly stable plate-screw systems, screw back-out is not a problem if the locking mechanism between the screws and the plate works. However, augmentation that will strengthen the bone around the screws can also be useful in conjunction with angle-stable plate-screw systems, as the augmentation will provide valuable support when subjected to loading that might cause cut-out. For many years conventional bone cement, polymethylmethacrylate (PMMA), has been used for augmentation, but due to side effects--including great difficulties if removal becomes necessary--the use of PMMA has never gained wide acceptance. With the introduction of bone substitutes, such as calcium phosphate cement, it has been shown that augmentation around screws can be achieved without the drawbacks seen with PMMA. When dealing with fixation of fractures in osteoporotic bone where screw stability might be inadequate, it

  20. Influence of Screw Length and Bone Thickness on the Stability of Temporary Implants

    PubMed Central

    Fernandes, Daniel Jogaib; Elias, Carlos Nelson; Ruellas, Antônio Carlos de Oliveira

    2015-01-01

    The purpose of this work was to study the influence of screw length and bone thickness on the stability of temporary implants. A total of 96 self-drilling temporary screws with two different lengths were inserted into polyurethane blocks (n = 66), bovine femurs (n = 18) and rabbit tibia (n = 12) with different cortical thicknesses (1 to 8 mm). Screws insertion in polyurethane blocks was assisted by a universal testing machine, torque peaks were collected by a digital torquemeter and bone thickness was monitored by micro-CT. The results showed that the insertion torque was significantly increased with the thickness of cortical bone from polyurethane (p < 0.0001), bovine (p = 0.0035) and rabbit (p < 0.05) sources. Cancellous bone improved significantly the mechanical implant stability. Insertion torque and insertion strength was successfully moduled by equations, based on the cortical/cancellous bone behavior. Based on the results, insertion torque and bone strength can be estimate in order to prevent failure of the cortical layer during temporary screw placement. The stability provided by a cortical thickness of 2 or 1 mm coupled to cancellous bone was deemed sufficient for temporary implants stability. PMID:28793582

  1. Influence of screw holes and gamma sterilization on properties of phosphate glass fiber-reinforced composite bone plates.

    PubMed

    Han, Na; Ahmed, Ifty; Parsons, Andrew J; Harper, Lee; Scotchford, Colin A; Scammell, Brigitte E; Rudd, Chris D

    2013-05-01

    Polymers prepared from polylactic acid (PLA) have found a multitude of uses as medical devices. For a material that degrades, the main advantage is that an implant would not necessitate a second surgical event for removal. In this study, fibers produced from a quaternary phosphate-based glass (PBG) in the system 50P2O5-40CaO-5Na2O-5Fe2O3 were used to reinforce PLA polymer. The purpose of this study was to assess the effect of screw holes in a range of PBG-reinforced PLA composites with varying fiber layup and volume fraction. The flexural properties obtained showed that the strength and modulus values increased with increasing fiber volume fraction; from 96 MPa to 320 MPa for strength and between 4 GPa and 24 GPa for modulus. Furthermore, utilizing a larger number of thinner unidirectional (UD) fiber prepreg layers provided a significant increase in mechanical properties, which was attributed to enhanced wet out and thus better fiber dispersion during production. The effect of gamma sterilization via flexural tests showed no statistically significant difference between the sterilized and nonsterilized samples, with the exception of the modulus values for samples with screw holes. Degradation profiles revealed that samples with screw holes degraded faster than those without screw holes due to an increased surface area for the plates with screw holes in PBS up to 30 days. Scanning electron microscope (SEM) analysis revealed fiber pullout before and after degradation. Compared with various fiber impregnation samples, with 25% volume fraction, 8 thinner unidirectional prepreg stacked samples had the shortest fiber pull-out lengths in comparison to the other samples investigated.

  2. Bone fracture repair - series (image)

    MedlinePlus

    ... by the following methods: a) one or more screws inserted across the break to hold it. b) a steel plate held by screws drilled into the bone. c) a long fluted metal pin with holes in it, is driven down the shaft of the bone ...

  3. Sinus grafting using recombinant human tissue factor, platelet-rich plasma gel, autologous bone, and anorganic bovine bone mineral xenograft: histologic analysis and case reports.

    PubMed

    Philippart, Pierre; Daubie, Valéry; Pochet, Roland

    2005-01-01

    The purpose of this study was to analyze healthy bone formation by means of histology and immunohistochemistry after grafting with a mixture of autologous ground calvarial bone, inorganic xenograft, platelet-rich plasma (PRP), and recombinant human tissue factor (rhTF). Maxillary sinus floor augmentation was performed on 3 patients by grafting with 5 to 10 mL of a paste consisting of autologous powder from calvarial bone (diameter < 1 mm), 50% v/v anorganic bovine bone mineral xenograft (PepGen P-15, a new tissue-engineered bone replacement graft material), PRP (1.8 x 10(6) platelets/mm3 plasma), and about 1 microg rhTF. Six and 10 months after grafting, bone cores were extracted for implant fixation and analyzed. Histology demonstrated a high degree of inorganic xenograft integration and natural bone regeneration. Both the xenograft and newly synthesized bone were colonized with osteocytes and surrounded by osteoblasts. Six-month-old bone cores demonstrated a ratio of synthesized bone to xenograft particles ratio of 0.5, whereas 10-month-old cores demonstrated a ratio of 2. A low degree of inflammation could also be observed using S100A8 immunohistochemistry. Autologous grafting in edentulous patients is a complex procedure; the successful substitution of synthetic analogs for ground bone is a major challenge. In this investigation, it was shown that inorganic xenograft in the harvested bone paste could be safe for patients and had high bone regeneration capacity over time. The sinus graft showed intense bone formation 6 months after grafting and a further increase in bone growth 10 months after grafting.

  4. The Biomechanical Properties of Pedicle Screw Fixation Combined With Trajectory Bone Cement Augmentation in Osteoporotic Vertebrae.

    PubMed

    Fan, Haitao T; Zhang, Renjie J; Shen, Cailiang L; Dong, Fulong L; Li, Yong; Song, Peiwen W; Gong, Chen; Wang, Yijin J

    2016-03-01

    The biomechanics of pedicle screw fixation combined with trajectory cement augmentation with various filling volumes were measured by pull-out, periodic antibending, and compression fatigue tests. To investigate the biomechanical properties of the pedicle screw fixation combined with trajectory bone cement (polymethylmethacrylate) augmentation in osteoporotic vertebrae and to explore the optimum filling volume of the bone cement. Pedicle screw fixation is considered to be the most effective posterior fixation method. The decrease of the bone mineral density apparently increases the fixation failure risk caused by screw loosening and displacement. Trajectory bone cement augmentation has been confirmed to be an effective method to increase the bone intensity and could markedly increase the stability of the fixation interface. Sixteen elderly cadaveric 1-5 lumbar vertebral specimens were diagnosed with osteoporosis. The left and right vertebral pedicles were alternatively randomized for treatment in all groups, with the contralateral pedicles as control. The study groups included: group A (pedicle screw fixation with full trajectory bone cement augmentation), group B (75% filling), group C (50% filling), and group D (25% filling). Finally, the bone cement leakage and dispersion were assessed and the mechanical testing was conducted. The bone cement was well dispersed around the pedicle screw. The augmented bone intensity, pull-out strength, periodic loading times, and compression fatigue performance were markedly higher than those of the control groups. With the increase in trajectory bone cement, the leakage was also increased (P<0.05). The pull-out strength of the pedicle screw was increased with an increase in bone mineral density and trajectory bone cement. It peaked at 75% filling, with the largest power consumption. The optimal filling volume of the bone cement was 75% of the trajectory volume (about 1.03 mL). The use of excessive bone cement did not increase

  5. In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique.

    PubMed

    Matsukawa, Keitaro; Yato, Yoshiyuki; Kato, Takashi; Imabayashi, Hideaki; Asazuma, Takashi; Nemoto, Koichi

    2014-02-15

    The insertional torque of pedicle screws using the cortical bone trajectory (CBT) was measured in vivo. To investigate the effectiveness of the CBT technique by measurement of the insertional torque. The CBT follows a mediolateral and caudocephalad directed path, engaging with cortical bone maximally from the pedicle to the vertebral body. Some biomechanical studies have demonstrated favorable characteristics of the CBT technique in cadaveric lumbar spine. However, no in vivo study has been reported on the mechanical behavior of this new trajectory. The insertional torque of pedicle screws using CBT and traditional techniques were measured intraoperatively in 48 consecutive patients. A total of 162 screws using the CBT technique and 36 screws using the traditional technique were compared. In 8 of 48 patients, the side-by-side comparison of 2 different insertional techniques for each vertebra were performed, which formed the H group. In addition, the insertional torque was correlated with bone mineral density. The mean maximum insertional torque of CBT screws and traditional screws were 2.49 ± 0.99 Nm and 1.24 ± 0.54 Nm, respectively. The CBT screws showed 2.01 times higher torque and the difference was significant between the 2 techniques (P < 0.01). In the H group, the insertional torque were 2.71 ± 1.36 Nm in the CBT screws and 1.58 ± 0.44 Nm in the traditional screws. The CBT screws demonstrated 1.71 times higher torque and statistical significance was achieved (P < 0.01). Positive linear correlations between maximum insertional torque and bone mineral density were found in both technique, the correlation coefficient of traditional screws (r = 0.63, P < 0.01) was higher than that of the CBT screws (r = 0.59, P < 0.01). The insertional torque using the CBT technique is about 1.7 times higher than the traditional technique. 2.

  6. Dynamic Stabilization of Simple Fractures With Active Plates Delivers Stronger Healing Than Conventional Compression Plating

    PubMed Central

    Tsai, Stanley; Bliven, Emily K.; von Rechenberg, Brigitte; Kindt, Philipp; Augat, Peter; Henschel, Julia; Fitzpatrick, Daniel C.; Madey, Steven M.

    2017-01-01

    Objectives: Active plates dynamize a fracture by elastic suspension of screw holes within the plate. We hypothesized that dynamic stabilization with active plates delivers stronger healing relative to standard compression plating. Methods: Twelve sheep were randomized to receive either a standard compression plate (CP) or an active plate (ACTIVE) for stabilization of an anatomically reduced tibial osteotomy. In the CP group, absolute stabilization was pursued by interfragmentary compression with 6 cortical screws. In the ACTIVE group, dynamic stabilization after bony apposition was achieved with 6 elastically suspended locking screws. Fracture healing was analyzed weekly on radiographs. After sacrifice 9 weeks postsurgery, the torsional strength of healed tibiae and contralateral tibiae was measured. Finally, computed tomography was used to assess fracture patterns and healing modes. Results: Healing in both groups included periosteal callus formation. ACTIVE specimens had almost 6 times more callus area by week 9 (P < 0.001) than CP specimens. ACTIVE specimens recovered on average 64% of their native strength by week 9, and were over twice as strong as CP specimens, which recovered 24% of their native strength (P = 0.008). Microcomputed tomography demonstrated that compression plating induced a combination of primary bone healing and gap healing. Active plating consistently stimulated biological bone healing by periosteal callus formation. Conclusions: Compared with compression plating, dynamic stabilization of simple fractures with active plates delivers significantly stronger healing. PMID:27861456

  7. Using Free Navigation Reference Points and Prefabricated Bone Plates for Zygoma Fracture Model Surgeries.

    PubMed

    Wang, Tien-Hsiang; Ma, Hsu; Tseng, Ching-Shiow; Chou, Yi-Hong; Cai, Kun-Lin

    Surgical navigation systems have been an important tool in maxillofacial surgery, helping surgeons create a presurgical plan, locate lesions, and provide guidance. For secondary facial bone reductions, a good presurgical plan and proper execution are the key to success. Previous studies used predetermined markers and screw holes as navigation references; however, unexpected situations may occur, making the predetermined surgical plan unreliable. Instead of determining positions preoperatively, this study proposes a method that surgeons can use intraoperatively to choose surface markers in a more flexible manner. Eight zygomatic fractures were created in four skull models, and preoperative computed tomography (CT) image data were imported into a self-developed navigation program for presurgical planning. This program also calculates the ideal positions of navigation references points for screw holes. During reduction surgery, markers on fractured bone are selected, registered, and calculated as free navigation reference points (FNRPs). The surface markers and FNRPs are used to monitor the position of the dislocated bone. Titanium bone plates were prefabricated on stereolithography models for osteosynthesis. Two reductions with only FNRPs, as well as six reductions with FNRPs and prefabricated bone plates, were successfully performed. Postoperative CT data were obtained, and surgical errors in the six-reduction group were evaluated. The average deviation from the screw hole drilling positions was 0.92 ± 0.38 mm. The average deviation included displacement and rotation of the zygomas. The mean displacement was 0.83 ± 0.38 mm, and the average rotations around the x, y, and z axes were 0.66 ± 0.59°, 0.77 ± 0.54°, and 0.79 ± 0.42°, respectively. The results show that combining presurgical planning and the developed navigation program to generate FNRPs for assisting in secondary zygoma reduction is an accurate and practical method. Further study is

  8. The biomechanical effect of artificial and human bone density on stopping and stripping torque during screw insertion.

    PubMed

    Tsuji, Matthew; Crookshank, Meghan; Olsen, Michael; Schemitsch, Emil H; Zdero, Rad

    2013-06-01

    Orthopedic surgeons apply torque to metal screws manually by "subjective feel" to obtain adequate fracture fixation, i.e. stopping torque, and attempt to avoid accidental over-tightening that leads to screw-bone interface failure, i.e. stripping torque. Few studies have quantified stripping torque in human bone, and only one older study from 1980 reported stopping/ stripping torque ratio. The present aim was to measure stopping and stripping torque of cortical and cancellous screws in artificial and human bone over a wide range of densities. Sawbone blocks were obtained having densities from 0.08 to 0.80g/cm(3). Sixteen fresh-frozen human femurs of known standardized bone mineral density (sBMD) were also used. Using a torque screwdriver, 3.5-mm diameter cortical screws and 6.5-mm diameter cancellous screws were inserted for adequate tightening as determined subjectively by an orthopedic surgeon, i.e. stopping torque, and then further tightened until failure of the screw-bone interface, i.e. stripping torque. There were weak (R=0.25) to strong (R=0.99) linear correlations of absolute and normalized torque vs. density or sBMD. Maximum stopping torques normalized by screw thread area engaged by the host material were 15.2N/mm (cortical screws) and 13.4N/mm (cancellous screws) in sawbone blocks and 20.9N/mm (cortical screws) and 6.1N/mm (cancellous screws) in human femurs. Maximum stripping torques normalized by screw thread area engaged by the host material were 23.4N/mm (cortical screws) and 16.8N/mm (cancellous screws) in sawbone blocks and 29.3N/mm (cortical screws) and 8.3N/mm (cancellous screws) in human femurs. Combined average stopping/ stripping torque ratios were 80.8% (cortical screws) and 76.8% (cancellous screws) in sawbone blocks, as well as 66.6% (cortical screws) and 84.5% (cancellous screws) in human femurs. Surgeons should be aware of stripping torque limits for human femurs and monitor stopping torque during surgery. This is the first study of the

  9. A histological study of stainless steel and titanium screws in bone.

    PubMed

    Millar, B G; Frame, J W; Browne, R M

    1990-04-01

    This study compared histologically the tissue response of stainless steel and titanium screws when inserted into the calvaria of eight beagle dogs for periods of 1, 4, 12, and 24 weeks. There was minimal fibrous reaction around both screw types with excellent long-term bone healing. After 24 weeks there was no discernable difference in the tissue reaction between the two types of screw.

  10. Biomechanical evaluation of a new MatrixMandible plating system on cadaver mandibles.

    PubMed

    Gateno, Jaime; Cookston, Christopher; Hsu, Sam Sheng-Pin; Stal, Drew N; Durrani, Salim K; Gold, Jonathan; Ismaily, Sabir; Alexander, Jerry W; Noble, Philip C; Xia, James J

    2013-11-01

    Current mandibular plating systems contain a wide range of plates and screws needed for the treatment of mandibular reconstruction and mandibular fractures. The authors' hypothesis was that a single diameter screw could be used in all applications in a plating system. Therefore, the purpose of this study was to test if the 2.0-mm locking screws could replace the 2.4-mm screws to stabilize a 2.5-mm-thick reconstruction plate in the treatment of mandibular discontinuity. Thirty-six fresh human cadaveric mandibles were used: 18 were plated using 2.0-mm locking screws (experimental) and the other 18 were plated using 2.4-mm locking screws (control). Each group was further divided into 3 subgroups based on the site of loading application: the ipsilateral (right) second premolar region, the central incisal region, and the contralateral (left) first molar region. The same ipsilateral (right) mandibular angular discontinuity was created by the same surgeon. The mandible was mounted on a material testing machine. The micromotions between the 2 segments, permanent and elastic displacements, were recorded after incremental ramping loads. The magnitude of screw back-out and the separation between plate and bone were recorded using a laser scanner (resolution, 0.12 mm) before and after the loading applications. The data were processed. Descriptive analyses and a general linear model for repeated measures analysis of variance were performed. There was no statistically significant difference in permanent displacement (mean, 1.16 and 0.82 mm, respectively) between the 2.0-mm and 2.4-mm screw groups. There also was no statistically significant difference in elastic displacement between the 2 groups (mean, 1.48 and 1.21 mm, respectively). Finally, there were no statistically significant differences in screw back-out or separation between plate and bone between the 2 groups. All means for screw back-out and separation between screw and bone for each group were judged within the

  11. Comminuted olecranon fracture fixation with pre-contoured plate: Comparison of composite and cadaver bones

    PubMed Central

    Hamilton Jr, David A; Reilly, Danielle; Wipf, Felix; Kamineni, Srinath

    2015-01-01

    AIM: To determine whether use of a precontoured olecranon plate provides adequate fixation to withstand supraphysiologic force in a comminuted olecranon fracture model. METHODS: Five samples of fourth generation composite bones and five samples of fresh frozen human cadaveric left ulnae were utilized for this study. The cadaveric specimens underwent dual-energy X-ray absorptiometry (DEXA) scanning to quantify the bone quality. The composite and cadaveric bones were prepared by creating a comminuted olecranon fracture and fixed with a pre-contoured olecranon plate with locking screws. Construct stiffness and failure load were measured by subjecting specimens to cantilever bending moments until failure. Fracture site motion was measured with differential variable resistance transducer spanning the fracture. Statistical analysis was performed with two-tailed Mann-Whitney-U test with Monte Carlo Exact test. RESULTS: There was a significant difference in fixation stiffness and strength between the composite bones and human cadaver bones. Failure modes differed in cadaveric and composite specimens. The load to failure for the composite bones (n = 5) and human cadaver bones (n = 5) specimens were 10.67 nm (range 9.40-11.91 nm) and 13.05 nm (range 12.59-15.38 nm) respectively. This difference was statistically significant (P ˂ 0.007, 97% power). Median stiffness for composite bones and human cadaver bones specimens were 5.69 nm/mm (range 4.69-6.80 nm/mm) and 7.55 nm/mm (range 6.31-7.72 nm/mm). There was a significant difference for stiffness (P ˂ 0.033, 79% power) between composite bones and cadaveric bones. No correlation was found between the DEXA results and stiffness. All cadaveric specimens withstood the physiologic load anticipated postoperatively. Catastrophic failure occurred in all composite specimens. All failures resulted from composite bone failure at the distal screw site and not hardware failure. There were no catastrophic fracture failures in the cadaveric

  12. Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength.

    PubMed

    Weiser, Lukas; Huber, Gerd; Sellenschloh, Kay; Viezens, Lennart; Püschel, Klaus; Morlock, Michael M; Lehmann, Wolfgang

    2017-11-01

    Loosening of pedicle screws is one major complication of posterior spinal stabilisation, especially in the patients with osteoporosis. Augmentation of pedicle screws with cement or lengthening of the instrumentation is widely used to improve implant stability in these patients. However, it is still unclear from which value of bone mineral density (BMD) the stability of pedicle screws is insufficient and an additional stabilisation should be performed. The aim of this study was to investigate the correlation of bone mineral density and pedicle screw fatigue strength as well as to define a threshold value for BMD below which an additional stabilisation is recommended. Twenty-one human T12 vertebral bodies were collected from donors between 19 and 96 years of age and the BMD was measured using quantitative computed tomography. Each vertebral body was instrumented with one pedicle screw and mounted in a servo-hydraulic testing machine. Fatigue testing was performed by implementing a cranio-caudal sinusoidal, cyclic (0.5 Hz) load with stepwise increasing peak force. A significant correlation between BMD and cycles to failure (r = 0.862, r 2  = 0.743, p < 0.001) as well as for the linearly related fatigue load was found. Specimens with BMD below 80 mg/cm 3 only reached 45% of the cycles to failure and only 60% of the fatigue load compared to the specimens with adequate bone quality (BMD > 120 mg/cm 3 ). There is a close correlation between BMD and pedicle screw stability. If the BMD of the thoracolumbar spine is less than 80 mg/cm 3 , stability of pedicle screws might be insufficient and an additional stabilisation should be considered.

  13. Immediate periodontal bone plate changes induced by rapid maxillary expansion in the early mixed dentition: CT findings

    PubMed Central

    Garib, Daniela Gamba; Menezes, Maria Helena Ocké; da Silva Filho, Omar Gabriel; dos Santos, Patricia Bittencourt Dutra

    2014-01-01

    Objective This study aimed at evaluating buccal and lingual bone plate changes caused by rapid maxillary expansion (RME) in the mixed dentition by means of computed tomography (CT). Methods The sample comprised spiral CT exams taken from 22 mixed dentition patients from 6 to 9 years of age (mean age of 8.1 years) presenting constricted maxillary arch treated with Haas-type expanders. Patients were submitted to spiral CT scan before expansion and after the screw activation period with a 30-day interval between T1 and T2. Multiplanar reconstruction was used to measure buccal and lingual bone plate thickness and buccal bone crest level of maxillary posterior deciduous and permanent teeth. Changes induced by expansion were evaluated using paired t test (p < 0.05). Results Thickness of buccal and lingual bone plates of posterior teeth remained unchanged during the expansion period, except for deciduous second molars which showed a slight reduction in bone thickness at the distal region of its buccal aspect. Buccal bone dehiscences were not observed in the supporting teeth after expansion. Conclusion RME performed in mixed dentition did not produce immediate undesirable effects on periodontal bone tissues. PMID:25162564

  14. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    PubMed

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  15. Study of new sheep bone and Zn/Ca ratio around TiAlV screw: PIXE RBS analysis

    NASA Astrophysics Data System (ADS)

    Guibert, G.; Munnik, F.; Langhoff, J. D.; Von Rechenberg, B.; Buffat, Ph. A.; Laub, D.; Faber, L.; Ducret, F.; Gerber, I.; Mikhailov, S.

    2008-03-01

    This study reports on in vivo particle induced X-ray emission (PIXE) measurements combined with Rutherford backscattering spectroscopy (RBS) analyses of new remodeled sheep bone formed around TiAlV screws. The implants (screws) were anodized by a modified TiMax™ process. The interface between the implant and the bone was carefully investigated. [Zn]/[Ca] in-depth composition profiles as well as Ca, Fe elemental maps were recorded. The thickness of new bone formed around the screw reached 300-400 μm. Osteon and Osteoid phases were identified in the new bone. A higher [Zn]/[Ca] ratio was observed in the new bone as compared to the mature bone. Blood vessels were observed in the bone in close contact with the screw. This study shows the potential of ion beam analysis for biological and biomedical characterization.

  16. Physicochemical characterization of porcine bone-derived grafting material and comparison with bovine xenografts for dental applications.

    PubMed

    Lee, Jung Heon; Yi, Gyu Sung; Lee, Jin Woong; Kim, Deug Joong

    2017-12-01

    The physicochemical properties of a xenograft are very important because they strongly influence the bone regeneration capabilities of the graft material. Even though porcine xenografts have many advantages, only a few porcine xenografts are commercially available, and most of their physicochemical characteristics have yet to be reported. Thus, in this work we aimed to investigate the physicochemical characteristics of a porcine bone grafting material and compare them with those of 2 commercially available bovine xenografts to assess the potential of xenogenic porcine bone graft materials for dental applications. We used various characterization techniques, such as scanning electron microscopy, the Brunauer-Emmett-Teller adsorption method, atomic force microscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, and others, to compare the physicochemical properties of xenografts of different origins. The porcine bone grafting material had relatively high porosity (78.4%) and a large average specific surface area (SSA; 69.9 m 2 /g), with high surface roughness (10-point average roughness, 4.47 µm) and sub-100-nm hydroxyapatite crystals on the surface. Moreover, this material presented a significant fraction of sub-100-nm pores, with negligible amounts of residual organic substances. Apart from some minor differences, the overall characteristics of the porcine bone grafting material were very similar to those of one of the bovine bone grafting material. However, many of these morphostructural properties were significantly different from the other bovine bone grafting material, which exhibited relatively smooth surface morphology with a porosity of 62.0% and an average SSA of 0.5 m 2 /g. Considering that both bovine bone grafting materials have been successfully used in oral surgery applications in the last few decades, this work shows that the porcine-derived grafting material possesses most of the key physiochemical characteristics required for its

  17. Use of the Er:YAG laser for improved plating in maxillofacial surgery: comparison of bone healing in laser and drill osteotomies.

    PubMed

    Lewandrowski, K U; Lorente, C; Schomacker, K T; Flotte, T J; Wilkes, J W; Deutsch, T F

    1996-01-01

    Surgical reconstruction of bony defects in the maxillofacial region involves fixation of bony fragments with mini and micro plates. Bone stabilization during hole drilling is often challenging due to the need to apply pressure when using a conventional mechanical Hall drill. In addition, fragmentation of the fragile bones may occur and complicate the reconstruction. The pulsed Er:YAG laser offers an attractive alternative drilling modality because it does not require physical contact with the bone in order to drill holes, cuts bone with minimal thermal damage, and allows precise control of bone cutting. The objective of this study was to investigate the pulsed Er:YAG laser as an alternative to the mechanical bur by comparing bone healing using both modalities. Bone healing in an inferior border defect of the rat mandible was examined using either an Er:YAG laser or a mechanical bur for drilling. The healing of osteotomies in facial bones and of screw holes for plate stabilization of free bone fragments was studied. All defects healed by 4 weeks postoperatively. Histologic evaluation demonstrated no difference in the amount of newly formed woven bone at the osteotomy site or screw holes made by either the laser or the drill. The extent of thermal damage at the osteotomy sites was comparable in laser and mechanically cut bone fragments. On the basis of this study we suggest that the Er: YAG laser can be used clinically in thin, fragile bones in the maxillofacial region.

  18. Bone anchors or interference screws? A biomechanical evaluation for autograft ankle stabilization.

    PubMed

    Jeys, Lee; Korrosis, Sotiris; Stewart, Todd; Harris, Nicholas J

    2004-01-01

    Autograft stabilization uses free semitendinosus tendon grafts to anatomically reconstruct the anterior talofibular ligament. Study aims were to evaluate the biomechanical properties of Mitek GII anchors compared with the Arthrex Bio-Tenodesis Screw for free tendon reconstruction of the anterior talofibular ligament. There are no differences in load to failure and percentage specimen elongation at failure between the 2 methods. Controlled laboratory study using porcine models. Sixty porcine tendon constructs were failure tested. Re-creating the pull of the anterior talofibular ligament, loads were applied at 70 degrees to the bones. Thirty-six tendons were fixed to porcine tali and tested using a single pull to failure; 10 were secured with anchors and No. 2 Ethibond, 10 with anchors and FiberWire, 10 with screws and Fiberwire, and 6 with partially gripped screws. Cyclic preloading was conducted on 6 tendons fixed by anchors and on 6 tendons fixed by screws before failure testing. Two groups of 6 components fixed to the fibula were also tested. The talus single-pull anchor group produced a mean load of 114 N and elongation of 37% at failure. The talus single-pull screw group produced a mean load of 227 N and elongation of 22% at failure (P <.05). Cyclic preloading at 65% failure load before failure testing produced increases in load and decreases in elongation at failure. Partially gripped screws produced a load of 133 N and elongation of 30% at failure. The fibula model produced significant increases in load to failure for both. The human anterior talofibular ligament has loads of 139 N at failure with instability occurring at 20% elongation. Interference screw fixation produced significantly greater failure strength and less elongation at failure than bone anchors. The improved biomechanics of interference screws suggests that these may be more suited to in vivo reconstruction of the anterior talofibular ligament than are bone anchors.

  19. Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model.

    PubMed

    Kiyak, Gorkem; Balikci, Tevfik; Heydar, Ahmed Majid; Bezer, Murat

    2018-02-01

    Mechanical study. To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-screw interface. Polyurethane blocks were used to mimic human osteoporotic cancellous bone, and six different screw designs were tested. Five standard and expandable screws without augmentation, eight expandable screws with polymethylmethacrylate (PMMA) or calcium phosphate augmentation, and distal cannulated screws with PMMA and calcium phosphate augmentation were tested. Mechanical tests were performed on 10 unused new screws of each group. Screws with or without augmentation were inserted in a block that was held in a fixture frame, and a longitudinal extraction force was applied to the screw head at a loading rate of 5 mm/min. Maximum load was recorded in a load displacement curve. The peak pullout force of all tested screws with or without augmentation was significantly greater than that of the standard pedicle screw. The greatest pullout force was observed with 40-mm expandable pedicle screws with four fins and PMMA augmentation. Augmented distal cannulated screws did not have a greater peak pullout force than nonaugmented expandable screws. PMMA augmentation provided a greater peak pullout force than calcium phosphate augmentation. Expandable pedicle screws had greater peak pullout forces than standard pedicle screws and had the advantage of augmentation with either PMMA or calcium phosphate cement. Although calcium phosphate cement is biodegradable, osteoconductive, and nonexothermic, PMMA provided a significantly greater peak pullout force. PMMA-augmented expandable 40-mm four-fin pedicle screws had the greatest peak pullout force.

  20. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  1. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  2. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  3. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  4. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  5. Analysis of plastic deformation in cortical bone after insertion of coated and non-coated self-tapping orthopaedic screws.

    PubMed

    Koistinen, A P; Korhonen, H; Kiviranta, I; Kröger, H; Lappalainen, R

    2011-07-01

    Insertion of internal fracture fixation devices, such as screws, mechanically weakens the bone. Diamond-like carbon has outstanding tribology properties which may decrease the amount of damage in tissue. The purpose of this study was to investigate methods for quantification of cortical bone damage after orthopaedic bone screw insertion and to evaluate the effect of surface modification on tissue damage. In total, 48 stainless steel screws were inserted into cadaver bones. Half of the screws were coated with a smooth amorphous diamond coating. Geometrical data of the bones was determined by peripheral quantitative computed tomography. Thin sections of the bone samples were prepared after screw insertion, and histomorphometric evaluation of damage was performed on images obtained using light microscopy. Micro-computed tomography and scanning electron microscopy were also used to examine tissue damage. A positive correlation was found between tissue damage and the geometric properties of the bone. The age of the cadaver significantly affected the bone mineral density, as well as the damage perimeter and diameter of the screw hole. However, the expected positive effect of surface modification was probably obscured by large variations in the results and, thus, statistically significant differences were not found in this study. This can be explained by natural variability in bone tissue, which also made automated image analysis difficult.

  6. Mini-Fragment Fixation Is Equivalent to Bicortical Screw Fixation for Horizontal Medial Malleolus Fractures.

    PubMed

    Wegner, Adam M; Wolinsky, Philip R; Robbins, Michael A; Garcia, Tanya C; Amanatullah, Derek F

    2018-05-01

    Horizontal fractures of the medial malleolus occur through application of valgus or abduction force through the ankle that creates a tension failure of the medial malleolus. The authors hypothesize that mini-fragment T-plates may offer improved fixation, but the optimal fixation construct for these fractures remains unclear. Forty synthetic distal tibiae with identical osteotomies were randomized into 4 fixation constructs: (1) two parallel unicortical cancellous screws; (2) two parallel bicortical cortical screws; (3) a contoured mini-fragment T-plate with 2 unicortical screws in the fragment and 2 bicortical screws in the shaft; and (4) a contoured mini-fragment T-plate with 2 bicortical screws in the fragment and 2 unicortical screws in the shaft. Specimens were subjected to offset axial tension loading on a servohydraulic testing system and tracked using high-resolution video. Failure was defined as 2 mm of articular displacement. Analysis of variance followed by a Tukey-Kramer post hoc test was used to assess for differences between groups, with significance defined as P<.05. The mean stiffness (±SD) values of both mini-fragment T-plate constructs (239±83 N/mm and 190±37 N/mm) and the bicortical screw construct (240±17 N/mm) were not statistically different. The mean stiffness values of both mini-fragment T-plate constructs and the bicortical screw construct were higher than that of a parallel unicortical screw construct (102±20 N/mm). Contoured T-plate constructs provide stiffer initial fixation than a unicortical cancellous screw construct. The T-plate is biomechanically equivalent to a bicortical screw construct, but may be superior in capturing small fragments of bone. [Orthopedics. 2018; 41(3):e395-e399.]. Copyright 2018, SLACK Incorporated.

  7. Condylar buttress plate versus fixed angle condylar blade plate versus dynamic condylar screw for supracondylar intra-articular distal femoral fractures.

    PubMed

    Petsatodis, George; Chatzisymeon, Apostolos; Antonarakos, Petros; Givissis, Panagiotis; Papadopoulos, Pericles; Christodoulou, Anastasios

    2010-04-01

    To compare outcomes of 3 fixation techniques for intra-articular distal femoral fractures. Records of 59 men and 49 women aged 16 to 80 (mean, 47) years who underwent internal fixation for 116 type-C (complete intra-articular) distal femoral fractures were retrospectively reviewed. According to the AO classification, 25 fractures were type C1 (23 closed and 2 open), 71 type C2 (69 closed and 2 open), and 20 type C3 (16 closed and 4 open). Based on implant availability at the time, all surgeries were performed by a single surgeon using a condylar buttress plate (n=38), a fixed angle (95 degrees) condylar blade plate (n=24), or a dynamic condylar screw (n=54). The mean follow-up period was 11 (range, 4-19) years. At the latest follow-up, functional outcome was classified according to Schatzker and Lambert criteria. Functional outcomes were excellent in 64 (55%) of the fractures, good in 37 (32%), moderate in 9 (8%), and poor in 6 (5%). Outcomes in patients treated by the dynamic condylar screw were significantly superior to those treated by the condylar buttress plate (p=0.016) or condylar blade plate (p=0.001). Good-to-excellent results were achieved in 96% vs 84% vs 71% of these patients, respectively. Complication rates were lower in the dynamic condylar screw group than the other 2 groups (pseudarthrosis, 5% vs 11% vs 25%; varus deformity, 4% vs 26% vs 25%; knee stiffness, 0% vs 5% vs 8%, respectively). No implant failure was encountered. Dynamic condylar screw fixation for distal femoral fractures achieves better functional outcomes and lower complication rates.

  8. Minimally invasive treatment of clavicular fractures with cannulated screw.

    PubMed

    Sun, Jun-zhan; Zheng, Guo-hai; Zhao, Ke-yi

    2014-05-01

    To evaluate minimally invasive treatment of clavicular fractures with cannulated screw. Data of 65 patients who had undergone minimally invasive treatment with cannulated screws for clavicular fractures from April 2009 to October 2010 were retrospectively analyzed and compared with those of 65 patients with clavicular fractures who had been treated by the same surgeons with plates. In the study group, there were 41 males and 24 females, aged from 19-67 years (mean, 35.8 years). According to Craig's classification, there were 29 group 1 and 36 of group 2-II. Neer scores were used to evaluate shoulder function and radiographs to assess fracture union. The incision length was 4-5 cm in the cannulated screw group (CSG) and 10-11 cm in the reconstructive plate group (RPG). Radiographs showed bone union was achieved in both groups, the bone healing time being 13.2 ± 6.9 weeks in the CSG and 16.3 ± 8.7 weeks in the RPG. All patients were followed up for 6 to 20 months (average, 10.6 months). The average Neer score was 96.6 ± 3.4 in the CSG and 94.2 ± 5.8 in the RPG. In the CSG, screw loosening occurred in five, and fracture displacement in three. There was a significant difference in fracture healing time between two groups but not in Neer score. Minimally invasive treatment of clavicular fractures with cannulated screws has the advantages of minimal invasion, short bone healing time, good clinical outcomes, and being relatively inexpensive. © 2014 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  9. In vivo degradation of a new concept of magnesium-based rivet-screws in the minipig mandibular bone.

    PubMed

    Schaller, Benoit; Saulacic, Nikola; Beck, Stefan; Imwinkelried, Thomas; Goh, Bee Tin; Nakahara, Ken; Hofstetter, Willy; Iizuka, Tateyuki

    2016-12-01

    Self-tapping of magnesium screws in hard bone may be a challenge due to the limited torsional strength of magnesium alloys in comparison with titanium. To avoid screw failure upon implantation, the new concept of a rivet-screw was applied to a WE43 magnesium alloy. Hollow cylinders with threads on the outside were expanded inside drill holes of minipig mandibles. During the expansion with a hexagonal mandrel, the threads engaged the surrounding bone and the inside of the screw transformed into a hexagonal screw drive to allow further screwing in or out of the implant. The in vivo degradation of the magnesium implants and the performance of the used coating were studied in a human standard-sized animal model. Four magnesium alloy rivet-screws were implanted in each mandible of 12 minipigs. Six animals received the plasmaelectrolytically coated magnesium alloy implants; another six received the uncoated magnesium alloy rivet-screws. Two further animals received one titanium rivet-screw each as control. In vivo radiologic examination was performed at one, four, and eight weeks. Euthanasia was performed for one group of seven animals (three animals with coated, three with uncoated magnesium alloy implants and one with titanium implant) at 12weeks and for the remaining seven animals at 24weeks. After euthanasia, micro-computed tomography and histological examination with histomorphometry were performed. Significantly less void formation as well as higher bone volume density (BV/TV) and bone-implant contact area (BIC) were measured around the coated implants compared to the uncoated ones. The surface coating was effective in delaying degradation despite plastic deformation. The results showed potential for further development of magnesium hollow coated screws for bone fixation. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Surgical strategies to improve fixation in the osteoporotic spine: the effects of tapping, cement augmentation, and screw trajectory.

    PubMed

    Kuhns, Craig A; Reiter, Michael; Pfeiffer, Ferris; Choma, Theodore J

    2014-02-01

    Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw insertion. Then we evaluated load to failure of screws placed in bone block models with a straight-ahead screw trajectory as well as with screws having a 23-degree cephalad trajectory (toward the end plate). These techniques were tested with nonaugmented (NA) screws as well as with bioactive cement (BioC) augmentation prior to screw insertion. Results In the NA group, pretapping decreased fixation strength in a dose-dependent fashion. In the BioC group, the tapped screws had significantly greater loads to failure (p < 0.01). Comparing only the screw orientation, the screws oriented at 23 degrees cephalad had a significantly higher failure force than their respective counterparts at 0 degrees (p < 0.01). Conclusions Standard pedicle screw fixation is often inadequate in the osteoporotic spine, but this study suggests tapping prior to cement augmentation will substantially improve fixation when compared with not tapping. Angulating screws more cephalad also seems to enhance aging spine fixation.

  11. Comparison of modern locked plating and antiglide plating for fixation of osteoporotic distal fibular fractures.

    PubMed

    Switaj, Paul J; Wetzel, Robert J; Jain, Neel P; Weatherford, Brian M; Ren, Yupeng; Zhang, Li-Qun; Merk, Bradley R

    2016-09-01

    Fractures in osteoporotic patients can be difficult to treat because of poor bone quality and inability to gain screw purchase. The purpose of this study is to compare modern lateral periarticular distal fibula locked plating to antiglide plating in the setting of an osteoporotic, unstable distal fibula fracture. AO/OTA 44-B2 distal fibula fractures were created in sixteen paired fresh frozen cadaveric ankles and fixed with a lateral locking plate and an independent lag screw or an antiglide plate with a lag screw through the plate. The specimens underwent stiffness, cyclic loading, and load to failure testing. The energy absorbed until failure, torque to failure, construct stiffness, angle at failure, and energy at failure was recorded. The lateral locking construct had a higher torque to failure (p=0.02) and construct stiffness (p=0.04). The locking construct showed a trend toward increased angle at failure, but did not reach statistical significance (p=0.07). Seven of the eight lateral locking plate specimens failed through the distal locking screws, while the antiglide plating construct failed with pullout of the distal screws and displacement of the fracture in six of the eight specimens. In our study, the newly designed distal fibula periarticular locking plate with increased distal fixation is biomechanically stronger than a non-locking one third tubular plate applied in antiglide fashion for the treatment of AO/OTA 44-B2 osteoporotic distal fibula fractures. V: This is an ex-vivo study performed on cadavers and is not a study performed on live patients. Therefore, this is considered Level V evidence. Copyright © 2015. Published by Elsevier Ltd.

  12. Percutaneous sacroiliac screw versus anterior plating for sacroiliac joint disruption: A retrospective cohort study.

    PubMed

    Zhang, Ruipeng; Yin, Yingchao; Li, Shilun; Hou, Zhiyong; Jin, Lin; Zhang, Yingze

    2018-02-01

    Sacroiliac joint disruption (SJD) is a common cause of pelvic ring instability. Clinically, percutaneous unilateral S1 sacroiliac screw and anterior plating are always applied to manage SJD. The objective of this study is to elaborate their respective therapeutic traits. Patients with SJD fixed with unilateral S1 sacroiliac screw or anterior plating from June 2011 to June 2015 were recruited into this study and were divided into two groups: group A (unilateral sacroiliac screw) and group B (anterior plating). Surgical time, blood loss, frequency of intraoperative fluoroscopy and complications were reviewed. Postoperative radiograph and CT were conducted to assess the reduction quality. Fracture healing was evaluated by radiograph performed at each follow-up. Majeed score was recorded at the final follow-up to assess the functional outcome. Thirty-eight patients were included in group A and thirty-two patients in group B in this study. There was no significant difference in the demographic data of the two groups. A significant difference existed in the results for average operation time (P = .022) and blood loss (P = .000) between group A and group B. The mean frequency of intraoperative fluoroscopy was 15.82 in group A and 3.94 in group B (P = .000). All the fractures healed in this study. The rates of satisfactory reduction quality and functional outcome showed no significant difference between the two groups (P > .05). The complication rate was 15.79% (6/38) in group A and 9.38% (3/32) in group B (P = .660). Compared with anterior plating, percutaneous unilateral S1 sacroiliac screw usage is less invasive; however, more intraoperative X-ray exposure and permanent neurologic damage may accompany this procedure. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality.

    PubMed

    Martín-Fernández, M; López-Herradón, A; Piñera, A R; Tomé-Bermejo, F; Duart, J M; Vlad, M D; Rodríguez-Arguisjuela, M G; Alvarez-Galovich, L

    2017-08-01

    Dramatic increases in the average life expectancy have led to increases in the variety of degenerative changes and deformities observed in the aging spine. The elderly population can present challenges for spine surgeons, not only because of increased comorbidities, but also because of the quality of their bones. Pedicle screws are the implants used most commonly in spinal surgery for fixation, but their efficacy depends directly on bone quality. Although polymethyl methacrylate (PMMA)-augmented screws represent an alternative for patients with osteoporotic vertebrae, their use has raised some concerns because of the possible association between cement leakages (CLs) and other morbidities. To analyze potential complications related to the use of cement-augmented screws for spinal fusion and to investigate the effectiveness of using these screws in the treatment of patients with low bone quality. A retrospective single-center study. This study included 313 consecutive patients who underwent spinal fusion using a total of 1,780 cement-augmented screws. We analyzed potential complications related to the use of cement-augmented screws, including CL, vascular injury, infection, screw extraction problems, revision surgery, and instrument failure. There are no financial conflicts of interest to report. A total of 1,043 vertebrae were instrumented. Cement leakage was observed in 650 vertebrae (62.3%). There were no major clinical complications related to CL, but two patients (0.6%) had radicular pain related to CL at the S1 foramina. Of the 13 patients (4.1%) who developed deep infections requiring surgical debridement, two with chronic infections had possible spondylitis that required instrument removal. All patients responded well to antibiotic therapy. Revision surgery was performed in 56 patients (17.9%), most of whom had long construction. A total of 180 screws were removed as a result of revision. There were no problems with screw extraction. These results

  14. LagLoc - a new surgical technique for locking plate systems.

    PubMed

    Triana, Miguel; Gueorguiev, Boyko; Sommer, Christoph; Stoffel, Karl; Agarwal, Yash; Zderic, Ivan; Helfen, Tobias; Krieg, James C; Krause, Fabian; Knobe, Matthias; Richards, R Geoff; Lenz, Mark

    2018-06-19

    Treatment of oblique and spiral fractures remains challenging. The aim of this study was to introduce and investigate the new LagLoc technique for locked plating with generation of interfragmentary compression, combining the advantages of lag-screw and locking-head-screw techniques. Oblique fracture was simulated in artificial diaphyseal bones, assigned to three groups for plating with a 7-hole locking compression plate. Group I was plated with three locking screws in holes 1, 4 and 7. The central screw crossed the fracture line. In group II the central hole was occupied with a lag screw perpendicular to fracture line. Group III was instrumented applying the LagLoc technique as follows. Hole 4 was predrilled perpendicularly to the plate, followed by overdrilling of the near cortex and insertion of a locking screw whose head was covered by a holding sleeve to prevent temporarily the locking in the plate hole and generate interfragmentary compression. Subsequently, the screw head was released and locked in the plate hole. Holes 1 and 7 were occupied with locking screws. Interfragmentary compression in the fracture gap was measured using pressure sensors. All screws in the three groups were tightened with 4Nm torque. Interfragmentary compression in group I (167 ± 25N) was significantly lower in comparison to groups II (431 ± 21N) and III (379 ± 59N), p≤0.005. The difference in compression between groups II and III remained not significant (p = 0.999). The new LagLoc technique offers an alternative tool to generate interfragmentary compression with the application of locking plates by combining the biomechanical advantages of lag screw and locking screw fixations. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Suitability of DCPs with screw locking elements to allow sufficient interfragmentary motion to promote secondary bone healing of osteoporotic fractures.

    PubMed

    Cuadrado, A; Yánez, A; Carta, J A; Garcés, G

    2013-06-01

    This paper analyses the suitability of a system comprising a Dynamic Compression Plate (DCP) and Screw Locking Elements (SLEs) to allow sufficient interfragmentary motion to promote secondary bone healing in osteoporotic fractures. Four fixation systems were mounted on bone-simulating reinforced epoxy bars filled with solid rigid polyurethane foam. Group 1, used for comparison purposes, represents a system comprised of a Locking Compression Plate (LCP) and eight locking screws. Groups 2 and 3 represent a system comprised of a DCP plate with eight cortical screws and two SLEs placed on the screws furthest from (group 2) and nearest to (group 3) the fracture. Group 4 represents the system comprised of a DCP plate with SLEs placed on all eight cortical screws. Cyclic compression tests of up to 10,000 load cycles were performed in order to determine the parameters of interest, namely the stiffnesses and the interfragmentary motion of the various configurations under consideration. Tukey's multiple comparison test was used to analyse the existence or otherwise of significant differences between the means of the groups. At 10,000 cycles, interfragmentary motion at the far cortex for group 2 was 0.60±0.04 mm and for group 3 0.59±0.03 mm (there being no significant differences: p=0.995). The mean interfragmentary motion at the far cortex of the LCP construct was 70% less than that of the two groups with 2SLEs (there being significant differences: p=1.1×10(-8)). In the case of group 4 this figure was 45% less than in groups 2 and 3 (there being significant differences: p=5.6×10(-6)). At 10,000 cycles, interfragmentary motion at the near cortex for group 2 was 0.24±0.06 mm and for group 3 0.24±0.03 mm (there being no significant differences: p=1.000). The mean interfragmentary motion at the near cortex of the LCP construct was 70.8% less than that of the two groups with 2SLEs (there being significant differences: p=0.011). In the case of group 4 this figure was 66

  16. Delayed Union of a Sacral Fracture: Percutaneous Navigated Autologous Cancellous Bone Grafting and Screw Fixation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huegli, R. W.; Messmer, P.; Jacob, A. L.

    2003-09-15

    Delayed or non-union of a sacral fracture is a serious clinical condition that may include chronic pain, sitting discomfort, gait disturbances, neurological problems, and inability to work. It is also a difficult reconstruction problem. Late correction of the deformity is technically more demanding than the primary treatment of acute pelvic injuries. Open reduction, internal fixation (ORIF), excision of scar tissue, and bone grafting often in a multi-step approach are considered to be the treatment of choice in delayed unions of the pelvic ring. This procedure implies the risk of neurological and vascular injuries, infection, repeated failure of union, incomplete correctionmore » of the deformity, and incomplete pain relief as the most important complications. We report a new approach for minimally invasive treatment of a delayed union of the sacrum without vertical displacement. A patient who suffered a Malgaigne fracture (Tile C1.3) was initially treated with closed reduction and percutaneous screw fixation (CRPF) of the posterior pelvic ring under CT navigation and plating of the anterior pelvic ring. Three months after surgery he presented with increasing hip pain caused by a delayed union of the sacral fracture. The lesion was successfully treated percutaneously in a single step procedure using CT navigation for drilling of the delayed union, autologous bone grafting, and screw fixation.« less

  17. Variable Bone Density of Scaphoid: Importance of Subchondral Screw Placement.

    PubMed

    Swanstrom, Morgan M; Morse, Kyle W; Lipman, Joseph D; Hearns, Krystle A; Carlson, Michelle G

    2018-02-01

    Background  Ideal internal fixation of the scaphoid relies on adequate bone stock for screw purchase; so, knowledge of regional bone density of the scaphoid is crucial. Questions/Purpose  The purpose of this study was to evaluate regional variations in scaphoid bone density. Materials and Methods  Three-dimensional CT models of fractured scaphoids were created and sectioned into proximal/distal segments and then into quadrants (volar/dorsal/radial/ulnar). Concentric shells in the proximal and distal pole were constructed in 2-mm increments moving from exterior to interior. Bone density was measured in Hounsfield units (HU). Results  Bone density of the distal scaphoid (453.2 ± 70.8 HU) was less than the proximal scaphoid (619.8 ± 124.2 HU). There was no difference in bone density between the four quadrants in either pole. In both the poles, the first subchondral shell was the densest. In both the proximal and distal poles, bone density decreased significantly in all three deeper shells. Conclusion  The proximal scaphoid had a greater density than the distal scaphoid. Within the poles, there was no difference in bone density between the quadrants. The subchondral 2-mm shell had the greatest density. Bone density dropped off significantly between the first and second shell in both the proximal and distal scaphoids. Clinical Relevance  In scaphoid fracture ORIF, optimal screw placement engages the subchondral 2-mm shell, especially in the distal pole, which has an overall lower bone density, and the second shell has only two-third the density of the first shell.

  18. [Cannulated lag screw combined with lateral supporting plate for treatment of Hoffa fracture of Letenneur type I and type III].

    PubMed

    Lin, Tao; Yang, Shuhua; Xiao, Baojun; Fu, Dehao

    2013-09-01

    To investigate the effectiveness of cannulated lag screws combined with lateral supporting plates in the treatment of Hoffa fracture of Letenneur type I and type III. Between May 2004 and April 2011, 11 patients with Hoffa fracture of Letenneur type I and type III were treated, including 6 males and 5 females with an average age of 36 years (range, 25-47 years). Factures were caused by traffic accident in 8 cases, by falling in 2 cases, and by the other in 1 case. Fracture involved the left knee in 7 patients and the right knee in 4 patients. According Letenneur's classification criteria, there were 7 type I fractures (6 lateral condyle fractures and 1 medial condyle fracture) and 4 type III fractures (3 lateral condyle fractures and 1 medial condyle fracture). Of 11 fractures, 9 were fresh fractures and 2 were old fractures. Two 6.5 mm cannulated lag screws combined with lateral supporting plates were used to fix fractures by anterolateral or anteromedial incision. All incisions achieved primary healing with no early complication. All patients were followed up 12-26 months (mean, 15 months). X-ray films showed bone healing with an average healing time of 15 weeks (range, 10-18 weeks). No loosening or breaking of internal fixator was observed; the removal time of internal fixation was 9-15 months (mean, 12 months). Accoding to Letenneur's functional assessment system, the results were excellent in 7 cases, good in 3 cases, and poor in 1 case at last follow-up. Cannulated lag screws combined with lateral supporting plates fixation is effective in treatment of Hoffa fracture of Letenneur type I and type III with a high union rate; anterolateral or anteromedial approach is the first choice for Hoffa fracture of type I and type III, especially for complicating by tibial plateau fracture or patella fracture.

  19. Comparison of Neck Screw and Conventional Fixation Techniques in Mandibular Condyle Fractures Using 3-Dimensional Finite Element Analysis.

    PubMed

    Conci, Ricardo Augusto; Tomazi, Flavio Henrique Silveira; Noritomi, Pedro Yoshito; da Silva, Jorge Vicente Lopes; Fritscher, Guilherme Genehr; Heitz, Claiton

    2015-07-01

    To compare the mechanical stress on the mandibular condyle after the reduction and fixation of mandibular condylar fractures using the neck screw and 2 other conventional techniques according to 3-dimensional finite element analysis. A 3-dimensional finite element model of a mandible was created and graphically simulated on a computer screen. The model was fixed with 3 different techniques: a 2.0-mm plate with 4 screws, 2 plates (1 1.5-mm plate and 1 2.0-mm plate) with 4 screws, and a neck screw. Loads were applied that simulated muscular action, with restrictions of the upper movements of the mandible, differentiation of the cortical and medullary bone, and the virtual "folds" of the plates and screws so that they could adjust to the condylar surface. Afterward, the data were exported for graphic visualization of the results and quantitative analysis was performed. The 2-plate technique exhibited better stability in regard to displacement of fractures, deformity of the synthesis materials, and minimum and maximum tension values. The results with the neck screw were satisfactory and were similar to those found when a miniplate was used. Although the study shows that 2 isolated plates yielded better results compared with the other groups using other fixation systems and methods, the neck screw could be an option for condylar fracture reduction. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.

    PubMed

    Malham, Gregory M; Parker, Rhiannon M

    2018-04-01

    OBJECTIVE Image guidance for spine surgery has been reported to improve the accuracy of pedicle screw placement and reduce revision rates and radiation exposure. Current navigation and robot-assisted techniques for percutaneous screws rely on bone-anchored trackers and Kirchner wires (K-wires). There is a paucity of published data regarding the placement of image-guided percutaneous screws without K-wires. A new skin-adhesive stereotactic patient tracker (SpineMask) eliminates both an invasive bone-anchored tracker and K-wires for pedicle screw placement. This study reports the authors' early experience with the use of SpineMask for "K-wireless" placement of minimally invasive pedicle screws and makes recommendations for its potential applications in lumbar fusion. METHODS Forty-five consecutive patients (involving 204 screws inserted) underwent K-wireless lumbar pedicle screw fixation with SpineMask and intraoperative neuromonitoring. Screws were inserted by percutaneous stab or Wiltse incisions. If required, decompression with or without interbody fusion was performed using mini-open midline incisions. Multimodality intraoperative neuromonitoring assessing motor and sensory responses with triggered electromyography (tEMG) was performed. Computed tomography scans were obtained 2 days postoperatively to assess screw placement and any cortical breaches. A breach was defined as any violation of a pedicle screw involving the cortical bone of the pedicle. RESULTS Fourteen screws (7%) required intraoperative revision. Screws were removed and repositioned due to a tEMG response < 13 mA, tactile feedback, and 3D fluoroscopic assessment. All screws were revised using the SpineMask with the same screw placement technique. The highest proportion of revisions occurred with Wiltse incisions (4/12, 33%) as this caused the greatest degree of SpineMask deformation, followed by a mini midline incision (3/26, 12%). Percutaneous screws via a single stab incision resulted in the

  1. [Biomaterials for bone filling: comparisons between autograft, hydroxyapatite and one highly purified bovine xenograft].

    PubMed

    Chappard, D; Zhioua, A; Grizon, F; Basle, M F; Rebel, A

    1993-12-01

    Bone grafts are becoming increasingly common in orthopaedics, neurosurgery and periodontology. Twenty one New Zealand rabbits were used in the present study comparing several materials usable as bone substitutes. A 4.5 mm hole was drilled in the inner femoral condyles. Holes were filled with either an autograft (from the opposite condyle), an hydroxylapatite (Bioapatite), or a highly purified bovine xenograft (T650 Lubboc). Animals were sacrificed at 1, 3 and 6 months post implantation and a quantitative analysis of newly-formed bone volume (BNF/IV) and remaining biomaterials (BMAT/IV) was done. In addition, some holes were left unfilled and served as controls. At 6 months, there was no tendency for spontaneous repair in the control animals. The autografted animals have repaired their trabecular mass and architecture within the first month. Hydroxylapatite appeared unresorbed at six months and only thin and scanty new trabeculae were observed. The xenograft induced woven bone trabeculae formation on the first month. This was associated with resorption of the material by two multinucleated cell populations. At six months, the epiphyseal architecture was restored and the biomaterial has disappeared in most cases. Xenografts appear a promising alternative to autografts and allografts, whose infectious risks and ethical problems should always be borne in mind.

  2. Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations.

    PubMed

    Estes, Chris; Rhee, Peter; Shrader, M Wade; Csavina, Kristine; Jacofsky, Marc C; Jacofsky, David J

    2008-01-01

    The purpose of this study was to compare the biomechanical properties of a contoured locking plate instrumented with either an all-locked or hybrid locked/nonlocked screw construct in a proximal metaphyseal fracture of the tibia (AO 41-A3.2). A standardized proximal metaphyseal wedge osteotomy (AO 41-A3.2) was created in five pairs of cadaveric tibia. Each pair was randomly instrumented with either an all-locked or combination locked/nonlocked screw construct using a locked contoured periarticular plate (Peri-Loc periarticular locked plating system, Smith & Nephew, Memphis, TN). Vertical subsidence (irreversible deformation) and deflection (reversible deformation) in each pair were analyzed and compared. Load to failure, defined by complete fracture gap closure, was also determined. There was no statistically significant difference in vertical subsidence (P = 0.19) or deflection (P = 0.19) of the proximal tibia between the all-locked and combination locked/nonlocked screw construct with increasing levels of cyclical axial load from 200 to 1200 N. Failure occurred at a mean value of 2160 N in the locked group and 1760 N in the hybrid group (P = 0.19); the failure mode was plate bending in all specimens. The results indicate that the use of compression screws with locked screws in this particular construct allows a similar amount of irreversible and reversible deformation in response to an axial load when compared to an all-locked screw construct. This suggests that there is no statistically significant difference in the stability in fixation between the two methods, allowing the surgeon the freedom to choose the appropriate screw combination unique to each fracture.

  3. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    PubMed

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  4. Internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones using bioabsorbable screws.

    PubMed

    Mageed, M; Steinberg, T; Drumm, N; Stubbs, N; Wegert, J; Koene, M

    2018-03-01

    Fractures involving the proximal one-third of the splint bone are relatively rare and are challenging to treat. A variety of management techniques have been reported in the literature. The aim of this retrospective case series was to describe the clinical presentation and evaluate the efficacy of bioabsorbable polylactic acid screws in internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones in horses. The medical records, diagnostic images and outcome of all horses diagnosed with a proximal fracture of the splint bones and treated with partial resection and internal fixation of the proximal stump using bioabsorbable polylactic acid screws between 2014 and 2015 were reviewed. Eight horses met the inclusion criteria. The results showed that there were no complications encountered during screw placement or postoperatively. Six horses returned to full work 3 months after the operation and two horses remained mildly lame. On follow-up radiographs 12 months postoperatively (n = 2) the screws were not completely absorbed. The screws resulted in a cone-shaped radiolucency, which was progressively replaced from the outer margins by bone sclerosis. The use of bioabsorbable screws for fixation of proximal fractures of the splint bone appears to be a safe and feasible technique and may offer several advantages over the use of traditional metallic implants. © 2018 Australian Veterinary Association.

  5. Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates

    PubMed Central

    Ganesh, VK; Ramakrishna, K; Ghista, Dhanjoo N

    2005-01-01

    Background In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress-shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress-shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress-shielding of the layer of the bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. Method In order to address this problem, we propose to use stiffness-graded plates. Accordingly, we have computed (by finite-element analysis) the stress distribution in the fractured bone fixed by composite plates, whose stiffness is graded both longitudinally and transversely. Results It can be seen that the stiffness-graded composite-plates cause less stress-shielding (as an example: at 50% of the healing stage, stress at the fracture interface is compressive in nature i.e. 0.002 GPa for stainless steel plate whereas stiffness graded plates provides tensile stress of 0.002 GPa. This means that stiffness graded plate is allowing the 50% healed bone to participate in loadings). Stiffness-graded plates are more flexible, and hence permit more bending of the fractured bone. This results in higher compressive stresses induced at the fractured faces accelerate bone-healing. On the other hand, away from the fracture interface the reduced stiffness and elastic modulus of the plate causes the neutral axis of the composite structure to be lowered into the bone resulting in the higher tensile stress in the bone-layer underneath the plate, wherein is conducive to the bone preserving its tensile strength. Conclusion Stiffness graded plates (with in-built variable stiffness) are deemed to offer less stress-shielding to the bone, providing higher compressive stress at the fractured interface (to induce accelerated healing) as well as higher tensile

  6. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

    PubMed

    Paulsson, Johnny; Stig, Josefine Corin; Olsson, Ola

    2017-08-24

    In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the respective treatment protocol, whereas one treatment protocol (Medoff sliding plate/dynamic hip screw) uses biaxial Medoff sliding plate for unstable pertrochanteric fractures and uniaxial Medoff sliding plate for subtrochanteric fractures, the second (intramedullary nail/dynamic hip screw) uses intramedullary nail for subtrochanteric fractures and for pertrochanteric fractures with intertrochanteric comminution or subtrochanteric extension. All orthopedic surgeries are registered in a regional database. All consecutive trochanteric fracture operations during 2011-2012 (n = 856) and subsequent technical reoperations (n = 40) were derived from the database. Reoperations were analysed and classified into the categories adjustment (percutaneous removal of the locking screw of the Medoff sliding plate or the intramedullary nail, followed by fracture healing) or minor, intermediate (reosteosynthesis) or major (hip joint replacement, Girdlestone or persistent nonunion) technical complications. The relative risk of intermediate or major technical complications was 4.2 (1.2-14) times higher in unstable pertrochanteric fractures and 4.6 (1.1-19) times higher in subtrochanteric fractures with treatment protocol: intramedullary nail/dynamic hip screw, compared to treatment protocol: Medoff sliding plate/dynamic hip screw. Overall rates of intermediate and major technical complications in unstable pertrochanteric and subtrochanteric fractures were with biaxial Medoff sliding plate 0.68%, with uniaxial Medoff sliding plate 1.4%, with dynamic hip screw 3.4% and with intramedullary nail 7.2%. The

  7. [The rotationally stable screw-anchor with trochanteric stabilizing plate (RoSA/TSP) : First results in unstable trochanteric femur fractures].

    PubMed

    Maier, K-J; Bücking, B; Horst, K; Andruszkow, H; Hildebrand, F; Knobe, M

    2017-12-01

    In unstable trochanteric fractures, the extramedullary rotationally stable screw-anchor (RoSA) combines the benefits of the load and rotational stability of the blade with the advantages of the screw (pull-out resistance, compression capability) in a single load carrier, and was designed to prevent femoral neck shortening by using an additional locked trochanteric stabilizing plate (TSP). The aim of the current prospective cohort study was the clinical evaluation of the RoSA/TSP system regarding the mechanical re-operation rate and the amount of postoperative femoral neck shortening. From September 2011 to January 2014 80 patients with unstable trochanteric fractures underwent internal extramedullary fixation with the RoSA/TSP (Königsee Implantate GmbH, Allendorf, Germany). Due to fracture stability and after induction of compression, additional long locked antitelescoping screws (AT, n = 1-4) were placed reaching the femoral head. Radiological (femoral neck shortening) and clinical re-examination of patients (n = 61) was performed 6-10 weeks and 6-10 months later. In the 61 re-examined patients (76 %) femoral neck shortening was very low with 2 mm 6-10 months after operation. Re-operations occurred in 8 % (n = 6) and in 4 % (n = 3) as prophylactic surgical intervention. Whereas one-third (4 %) of re-operations occurred due to iatrogenic surgical problems from the first operation two-thirds of patients (8 %) had a re-operation due to delay of bone union (3× nonunion, 3 planned removals of AT-screws to improve healing). The in-hospital mortality was 3 % (n = 2). The fixation of unstable trochanteric femur fractures using the RoSA/TSP in a first clinical setting led to a great primary stability, with significant advantages with regard to limited femoral neck shortening. However, the rigidity of the construct with its consequences regarding bone healing can be challenging for the surgeon. Nevertheless, in some cases of revision it could be beneficial

  8. Distal radius osteotomy with volar locking plates based on computer simulation.

    PubMed

    Miyake, Junichi; Murase, Tsuyoshi; Moritomo, Hisao; Sugamoto, Kazuomi; Yoshikawa, Hideki

    2011-06-01

    Corrective osteotomy using dorsal plates and structural bone graft usually has been used for treating symptomatic distal radius malunions. However, the procedure is technically demanding and requires an extensive dorsal approach. Residual deformity is a relatively frequent complication of this technique. We evaluated the clinical applicability of a three-dimensional osteotomy using computer-aided design and manufacturing techniques with volar locking plates for distal radius malunions. Ten patients with metaphyseal radius malunions were treated. Corrective osteotomy was simulated with the help of three-dimensional bone surface models created using CT data. We simulated the most appropriate screw holes in the deformed radius using computer-aided design data of a locking plate. During surgery, using a custom-made surgical template, we predrilled the screw holes as simulated. After osteotomy, plate fixation using predrilled screw holes enabled automatic reduction of the distal radial fragment. Autogenous iliac cancellous bone was grafted after plate fixation. The median volar tilt, radial inclination, and ulnar variance improved from -20°, 13°, and 6 mm, respectively, before surgery to 12°, 24°, and 1 mm, respectively, after surgery. The median wrist flexion improved from 33° before surgery to 60° after surgery. The median wrist extension was 70° before surgery and 65° after surgery. All patients experienced wrist pain before surgery, which disappeared or decreased after surgery. Surgeons can operate precisely and easily using this advanced technique. It is a new treatment option for malunion of distal radius fractures.

  9. Orthodontic skeletal anchorage using a palatal external plate.

    PubMed

    Kobayashi, Masaru; Fushima, Kenji

    2014-03-01

    We have developed the Anchor-Lock external plate system, which is fitted on the palate for the purpose of orthodontic skeletal anchorage. The aim of this study was to introduce the Anchor-Lock and assess its success rate. The Anchor-Lock is composed of titanium screws of 2·0-mm diameter and a titanium plate of 1·0-mm thickness. The external plate is rigidly interlocked with the heads of the screws, which are implanted trans-mucosally into palatal bone. Three types of Anchor-Lock are available. These were applied to 137 orthodontic patients (104 females and 33 males) aged 10-54 years. Two types of plate were used, a straight-shaped plate applied to the hard palate and to the anterior palate and a double-Y-shaped plate applied after tooth-borne rapid maxillary expansion. Success rate of the Anchor-Lock was 92·0% overall. No significant difference in success rate was found by age or sex of patients. Type or screw length of the Anchor-Lock did not affect success rate significantly. Success rate was significantly increased by the use of the surgical stent. The Anchor-Lock was effectively applied to distalize and/or intrude the upper molars. The Anchor-Lock system appears suitable for clinical use as an alternative to conventional screw- and plate-type orthodontic implants.

  10. Maintaining space in localized ridge augmentation using guided bone regeneration with tenting screw technology.

    PubMed

    Chasioti, Evdokia; Chiang, Tat Fai; Drew, Howard J

    2013-01-01

    Prosthetic guided implant surgery requires adequate ridge dimensions for proper implant placement. Various surgical procedures can be used to augment deficient alveolar ridges. Studies have examined new bone formation on deficient ridges, utilizing numerous surgical techniques and biomaterials. The goal is to develop time efficient techniques, which have low morbidity. A crucial factor for successful bone grafting procedures is space maintenance. The article discusses space maintenance tenting screws, used in conjunction with bone allografts and resorbable barrier membranes, to ensure uneventful guided bone regeneration (GBR) enabling optimal implant positioning. The technique utilized has been described in the literature to treat severely resorbed alveolar ridges and additionally can be considered in restoring the vertical and horizontal component of deficient extraction sites. Three cases are presented to illustrate the utilization and effectiveness of tenting screw technology in the treatment of atrophic extraction sockets and for deficient ridges.

  11. Effect of screw position on load transfer in lumbar pedicle screws: A non-idealized finite element analysis

    PubMed Central

    Newcomb, Anna G. U. S.; Baek, Seungwon; Kelly, Brian P.; Crawford, Neil R.

    2016-01-01

    Angled screw insertion has been advocated to enhance fixation strength during posterior spine fixation. Stresses on a pedicle screw and surrounding vertebral bone with different screw angles were studied by finite element analysis during simulated multidirectional loading. Correlations between screw-specific vertebral geometric parameters and stresses were studied. Angulations in both the sagittal and axial planes affected stresses on the cortical and cancellous bones and the screw. Pedicle screws pointing laterally (vs. straight or medially) in the axial plane during superior screw angulation may be advantageous in terms of reducing the risk of both screw loosening and screw breakage. PMID:27454197

  12. Biomechanical comparison of 3.0 mm headless compression screw and 3.5 mm cortical bone screw in a canine humeral condylar fracture model.

    PubMed

    Gonsalves, Mishka N; Jankovits, Daniel A; Huber, Michael L; Strom, Adam M; Garcia, Tanya C; Stover, Susan M

    2016-09-20

    To compare the biomechanical properties of simulated humeral condylar fractures reduced with one of two screw fixation methods: 3.0 mm headless compression screw (HCS) or 3.5 mm cortical bone screw (CBS) placed in lag fashion. Bilateral humeri were collected from nine canine cadavers. Standardized osteotomies were stabilized with 3.0 mm HCS in one limb and 3.5 mm CBS in the contralateral limb. Condylar fragments were loaded to walk, trot, and failure loads while measuring construct properties and condylar fragment motion. The 3.5 mm CBS-stabilized constructs were 36% stiffer than 3.0 mm HCS-stabilized constructs, but differences were not apparent in quality of fracture reduction nor in yield loads, which exceeded expected physiological loads during rehabilitation. Small residual fragment displacements were not different between CBS and HCS screws. Small fragment rotation was not significantly different between screws, but was weakly correlated with moment arm length (R² = 0.25). A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.

  13. Histological comparison of autograft, allograft-DBM, xenograft, and synthetic grafts in a trabecular bone defect: an experimental study in rabbits.

    PubMed

    Athanasiou, Vasilis T; Papachristou, Dionysios J; Panagopoulos, Andreas; Saridis, Alkis; Scopa, Chrisoula D; Megas, Panagiotis

    2010-01-01

    Different types of bone-graft substitutes have been developed and are on the market worldwide to eliminate the drawbacks of autogenous grafting. This experimental animal study was undertaken to evaluate the different histological properties of various bone graft substitutes utilized in this hospital. Ninety New Zealand white rabbits were divided into six groups of 15 animals. Under general anesthesia, a 4.5 mm-wide hole was drilled into both the lateral femoral condyles of each rabbit, for a total of 180 condyles for analysis. The bone defects were filled with various grafts, these being 1) autograft, 2) DBM crunch allograft (Grafton), 3) bovine cancellous bone xenograft (Lubboc), 4) calcium phosphate hydroxyapatite substitute (Ceraform), 5) calcium sulfate substitute (Osteoset), and 6) no filling (control). The animals were sacrificed at 1, 3, and 6 months after implantation and tissue samples from the implanted areas were processed for histological evaluation. A histological grading scale was designed to determine the different histological parameters of bone healing. The highest histological grades were achieved with the use of cancellous bone autograft. Bovine xenograft (Lubboc) was the second best in the histological scale grading. The other substitutes (Grafton, Ceraform, Osteoset) had similar scores but were inferior to both allograft and xenograft. Bovine xenograft showed better biological response than the other bone graft substitutes; however, more clinical studies are necessary to determine its overall effectiveness.

  14. In Vivo Evaluation of Immediately Loaded Stainless Steel and Titanium Orthodontic Screws in a Growing Bone

    PubMed Central

    Gritsch, Kerstin; Laroche, Norbert; Bonnet, Jeanne-Marie; Exbrayat, Patrick; Morgon, Laurent; Rabilloud, Muriel; Grosgogeat, Brigitte

    2013-01-01

    The present work intends to evaluate the use of immediate loaded orthodontic screws in a growing model, and to study the specific bone response. Thirty-two screws (half of stainless steel and half of titanium) were inserted in the alveolar bone of 8 growing pigs. The devices were immediately loaded with a 100 g orthodontic force. Two loading periods were assessed: 4 and 12 weeks. Both systems of screws were clinically assessed. Histological observations and histomorphometric analysis evaluated the percent of “bone-to-implant contact” and static and dynamic bone parameters in the vicinity of the devices (test zone) and in a bone area located 1.5 cm posterior to the devices (control zone). Both systems exhibit similar responses for the survival rate; 87.5% and 81.3% for stainless steel and titanium respectively (p = 0.64; 4-week period), and 62.5% and 50.0% for stainless steel and titanium respectively (p = 0.09; 12-week period). No significant differences between the devices were found regarding the percent of “bone-to-implant contact” (p = 0.1) or the static and dynamic bone parameters. However, the 5% threshold of “bone-to-implant contact” was obtained after 4 weeks with the stainless steel devices, leading to increased survival rate values. Bone in the vicinity of the miniscrew implants showed evidence of a significant increase in bone trabecular thickness when compared to bone in the control zone (p = 0.05). In our study, it is likely that increased trabecular thickness is a way for low density bone to respond to the stress induced by loading. PMID:24124540

  15. Simulation of mechanical behavior and optimization of simulated injection molding process for PLA based antibacterial composite and nanocomposite bone screws using central composite design.

    PubMed

    Heidari, Behzad Shiroud; Oliaei, Erfan; Shayesteh, Hadi; Davachi, Seyed Mohammad; Hejazi, Iman; Seyfi, Javad; Bahrami, Mozhgan; Rashedi, Hamid

    2017-01-01

    In this study, injection molding of three poly lactic acid (PLA) based bone screws was simulated and optimized through minimizing the shrinkage and warpage of the bone screws. The optimization was carried out by investigating the process factors such as coolant temperature, mold temperature, melt temperature, packing time, injection time, and packing pressure. A response surface methodology (RSM), based on the central composite design (CCD), was used to determine the effects of the process factors on the PLA based bone screws. Upon applying the method of maximizing the desirability function, optimization of the factors gave the lowest warpage and shrinkage for nanocomposite PLA bone screw (PLA9). Moreover, PLA9 has the greatest desirability among the selected materials for bone screw injection molding. Meanwhile, a finite element analysis (FE analysis) was also performed to determine the force values and concentration points which cause yielding of the screws under certain conditions. The Von-Mises stress distribution showed that PLA9 screw is more resistant against the highest loads as compared to the other ones. Finally, according to the results of injection molding simulations, the design of experiments (DOE) and structural analysis, PLA9 screw is recommended as the best candidate for the production of biomedical materials among all the three types of screws. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Finite element analysis of functionally graded bone plate at femur bone fracture site

    NASA Astrophysics Data System (ADS)

    Satapathy, Pravat Kumar; Sahoo, Bamadev; Panda, L. N.; Das, S.

    2018-03-01

    This paper focuses on the analysis of fractured Femur bone with functionally graded bone plate. The Femur bone is modeled by using the data from the CT (Computerized Tomography) scan and the material properties are assigned using Mimics software. The fracture fixation plate used here is composed of Functionally Graded Material (FGM). The functionally graded bone plate is considered to be composed of different layers of homogeneous materials. Finite element method approach is adopted for analysis. The volume fraction of the material is calculated by considering its variation along the thickness direction (z) according to a power law and the effective properties of the homogeneous layers are estimated. The model developed is validated by comparing numerical results available in the literature. Static analysis has been performed for the bone plate system by considering both axial compressive load and torsional load. The investigation shows that by introducing FG bone plate instead of titanium, the stress at the fracture site increases by 63 percentage and the deformation decreases by 15 percentage, especially when torsional load is taken into consideration. The present model yields better results in comparison with the commercially available bone plates.

  17. Pedicle screw-rod fixation: a feasible treatment for dogs with severe degenerative lumbosacral stenosis.

    PubMed

    Tellegen, Anna R; Willems, Nicole; Tryfonidou, Marianna A; Meij, Björn P

    2015-12-07

    Degenerative lumbosacral stenosis is a common problem in large breed dogs. For severe degenerative lumbosacral stenosis, conservative treatment is often not effective and surgical intervention remains as the last treatment option. The objective of this retrospective study was to assess the middle to long term outcome of treatment of severe degenerative lumbosacral stenosis with pedicle screw-rod fixation with or without evidence of radiological discospondylitis. Twelve client-owned dogs with severe degenerative lumbosacral stenosis underwent pedicle screw-rod fixation of the lumbosacral junction. During long term follow-up, dogs were monitored by clinical evaluation, diagnostic imaging, force plate analysis, and by using questionnaires to owners. Clinical evaluation, force plate data, and responses to questionnaires completed by the owners showed resolution (n = 8) or improvement (n = 4) of clinical signs after pedicle screw-rod fixation in 12 dogs. There were no implant failures, however, no interbody vertebral bone fusion of the lumbosacral junction was observed in the follow-up period. Four dogs developed mild recurrent low back pain that could easily be controlled by pain medication and an altered exercise regime. Pedicle screw-rod fixation offers a surgical treatment option for large breed dogs with severe degenerative lumbosacral stenosis with or without evidence of radiological discospondylitis in which no other treatment is available. Pedicle screw-rod fixation alone does not result in interbody vertebral bone fusion between L7 and S1.

  18. Influence of cement compressive strength and porosity on augmentation performance in a model of orthopedic screw pull-out.

    PubMed

    Pujari-Palmer, Michael; Robo, Celine; Persson, Cecilia; Procter, Philip; Engqvist, Håkan

    2018-01-01

    Disease and injuries that affect the skeletal system may require surgical intervention and internal fixation, i.e. orthopedic plate and screw insertion, to stabilize the injury and facilitate tissue repair. If the surrounding bone quality is poor the screws may migrate, or the bone may fail, resulting in fixation failure. While numerous studies have shown that cement augmentation of the interface between bone and implant can increase screw pull-out force, the physical properties of cement that influence pull-out force have not been investigated. The present study sought to determine how the physical properties of high strength calcium phosphate cements (hsCPCs, specifically dicalcium phosphate) affected the corresponding orthopedic screw pull-out force in urethane foam models of "healthy" and "osteoporotic" synthetic bone (Sawbones). In the simplest model, where only the bond strength between screw thread and cement (without Sawbone) was tested, the correlation between pull-out force and cement compressive strength (R 2 = 0.79) was weaker than correlation with total cement porosity (R 2 = 0.89). In open pore Sawbone that mimics "healthy" cancellous bone density the stronger cements produced higher pull-out force (50-60% increase). High strength, low porosity cements also produced higher pull-out forces (50-190% increase) in "healthy" Sawbones with cortical fixation if the failure strength of the cortical material was similar to, or greater than (a metal shell), actual cortical bone. This result is of particular clinical relevance where fixation with a metal plate implant is indicated, as the nearby metal can simulate a thicker cortical shell, thereby increasing the pull-out force of screws augmented with stronger cements. The improvement in pull-out force was apparent even at low augmentation volumes of 0.5mL (50% increase), which suggest that in clinical situations where augmentation volume is limited the stronger, lower porosity calcium phosphate cement (CPC) may

  19. Insertion torque in different bone models with different screw pitch: an in vitro study.

    PubMed

    Orlando, Bruno; Barone, Antonio; Giorno, Thierry M; Giacomelli, Luca; Tonelli, Paolo; Covani, Ugo

    2010-01-01

    Orthopedic surgeons use different types of screws for bone fixation. Whereas hard cortical bone requires a screw with a fine pitch, in softer cancellous bone a wider pitch might help prevent micromotion and eventually lead to greater implant stability. The aim of this study was to validate the assumption that fine-pitch implants are appropriate for cortical bone and wide-pitch implants are appropriate for cancellous bone. Wide-pitch and fine-pitch implants were inserted in both hard (D1 and D2) bone and soft (D3 and D4) bone, which was simulated by separate experimental blocks of cellular rigid polyurethane foam. A series of insertion sites in D1-D2 and D3-D4 experimental blocks were prepared using 1.5-mm and 2.5-mm drills. The final torque required to insert each implant was recorded. Wide-pitch implants displayed greater insertion torque (20% more than the fine-pitch implants) in cancellous bone and were therefore more suitable than fine-pitch implants. It is more appropriate to use a fine pitch design for implants, in conjunction with a 2.5-mm osteotomy site, in dense cortical bone (D1 or D2), whereas it is recommended to choose a wide-pitch design for implants, in conjunction with a 1.5-mm osteotomy site, in softer bone (D3 or D4).

  20. Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures

    PubMed Central

    Meffert, Rainer H.; Raschke, Michael J.; Blunk, Torsten; Ochman, Sabine

    2014-01-01

    Purpose. To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. Methods. Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduction and stabilization with a nonlocking and a comparable locking plate in mono- or bicortical screw fixation followed. Under cyclic loading, the displacement, and in subsequent load-to-failure tests, the maximum load and stiffness were measured. Results. For the monocortical screw fixation of the locking plate, a similar displacement, maximum load, and stiffness could be demonstrated compared to the bicortical screw fixation of the nonlocking plate. Conclusions. Locking plates in monocortical configuration may function as a useful alternative to the currently common treatment with bicortical fixations. Thereby, irritation of the flexor tendons would be avoided without compromising the stability, thus enabling the necessary early functional rehabilitation. PMID:24757429

  1. Operculum bone carp (cyprinus carprio sp.) scaffold is a new potential xenograft material: a preliminary study

    NASA Astrophysics Data System (ADS)

    Kartiwa, A.; Abbas, B.; Pandansari, P.; Prahasta, A.; Nandini, M.; Fadhlillah, M.; Subroto, T.; Panigoro, R.

    2017-02-01

    Orbital floor fracture with extensive bone loss, would cause herniation of the orbital tissue into the maxillary sinus. Graft implantation should be done on the orbital fracture with extensive bone loss. Different types of grafts have their own characteristics and advantages. Xenograft has been widely studied for use in bone defects. This study was to investigate cyprinus carprio sp. opercula bone as a potential xenograft. The aim of this study was to investigate based on EDS chemical analysis using a ZAF Standardless Method of Quantitative Analysis (Oxide) and SEM examination conducted in the laboratory of Mathematics, Institute of Technology Bandung. Particularly the mass ratio of Ca and P (5.8/3:47), the result is 1.67. This is equivalent to the stoichiometric Hydroxyapatite (HA) (Aoki H, 1991, Science and medical applications of hydroxyapatite, Tokyo: Institute for Medical and Engineering, Tokyo Medical and Dental University). C N O that there is an element of protein/amino acid collagen compound, serves as a matrix together with HA. As shown in the SEM analysis that the matrix is a porous sheet-shaped (oval) that interconnect with each other, which is good scaffold. The pore is composed of large pores >200 microns and smaller pores between the large pores with a size smaller or equal to 10 microns that can serve for the attachment of osteoblast cell. In conclusion, Opercula bone carp (cyprinus carprio sp.) scaffold could be a new potential xenograft material.

  2. Reoperative surgical stabilization of a painful nonunited rib fracture using bone grafting and a metal plate.

    PubMed

    Cho, Yang Hyun; Kim, Hyun Koo; Kang, Du-Young; Choi, Young Ho

    2009-09-01

    We report a case of a nonunited sixth rib in a patient with multiple rib fractures who underwent internal fixation using a wire and Judet strut 3 times. During the following 3 years, the patient continued to complain of pain and instability. At surgery, a pseudarthrosis between the ends of the sixth rib was excised. A longitudinal gutter crossing the fracture site was fashioned and splinted with an inlay block of cancellous bone grafted from the iliac crest; stabilization was accomplished with a reconstruction plate and screws. The following 2 years of follow-up demonstrated no instability or pain.

  3. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    PubMed

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  4. Continuous decompression of unicameral bone cyst with cannulated screws: a comparative study.

    PubMed

    Brecelj, Janez; Suhodolcan, Lovro

    2007-09-01

    We determined the role of mechanical decompression in the resolution of unicameral bone cyst. A total of 69 children with unicameral bone cysts were treated either by (i) open curettage and bone grafting, (ii) steroid injection or (iii) cannulated screw insertion. During a mean follow-up of 69 months (range, 12-58), the cysts were evaluated by radiological criteria. The healing rates in the three groups were 25, 12 and 29% after the first treatment, and a further 50, 19 and 65% after the second. The study has demonstrated the advantages of the decompression technique for unicameral bone cysts over other treatment modalities studied.

  5. Biomechanical evaluation of a new composite bioresorbable screw.

    PubMed

    Bailey, C A; Kuiper, J H; Kelly, C P

    2006-04-01

    A new bioresorbable composite cannulated screw has been developed for small bone fracture fixation. The LG ("Little Grafter") screw is manufactured from Biosteon, which is a composite of poly L-lactic acid and hydroxyapatite. This study aimed to compare interfragmentary compression generated by this new screw with conventional metal screws commonly used in scaphoid fracture fixation. Four small metallic screws were compared with the LG screw, using a bone model produced from rigid polyurethane foam. The screws included the Acutrak, Asnis III, Herbert and Herbert-Whipple screws. The mean maximum compression forces for the LG screw, the Asnis and the Acutrak were comparable (LG 32.3 N, Asnis 32.8 N, Acutrak 38.3 N), whereas those using the Herbert and the Herbert-Whipple screw were significantly lower (Herbert 21.8 N, Herbert-Whipple 19.9 N). The bioresorbable LG screw has been shown to have good compressive properties compared to commonly used small bone fragment compression screws.

  6. Role of autologous non-vascularised intramedullary fibular strut graft in humeral shaft nonunions following failed plating.

    PubMed

    Kashayi-Chowdojirao, Sreekanth; Vallurupalli, Aashish; Chilakamarri, Vijay Krishna; Patnala, Chandrasekhar; Chodavarapu, Lalith Mohan; Kancherla, Nageswara Rao; Khazi Syed, Asif Hussain

    2017-11-01

    Non-union humeral shaft fractures are seen frequently in clinical practice at about 2-10% in conservative management and 30% in surgically operated patients. Osteosynthesis using dynamic compression plate (DCP), intramedullary nailing, locking compression plate (LCP), Ilizarov technique along with bone grafting have been reported previously. In cases of prior failed plate-screw osteosynthesis the resultant osteopenia, cortical defect, bone loss, scalloping around screws and metallosis, make the management of non-union more complicated. Fibular graft as an intramedullary strut is useful in these conditions by increasing screw purchase, union and mechanical stability. This study is a retrospective and prospective follow up of revision plating along with autologous non-vascularised intramedullary fibular strut graft (ANVFG) for humeral non-unions following failed plate osteosynthesis. Seventy eight cases of nonunion humeral shaft fractures were managed in our institute between 2008 and 2015. Of these, 57 cases were failed plate osteosynthesis, in which 15 cases were infected and 42 cases were noninfected. Out of the 78 cases, bone grafting was done in 55 cases. Fibular strut graft was used in 22 patients, of which 4 cases were of primary nonunion with osteoporotic bone. Applying the exclusion criteria of infection and inclusion criteria of failed plate osteosynthesis managed with revision plating using either LCP or DCP and ANVFG, 17 cases were studied. The mean age of the patients was 40.11 yrs (range: 26-57 yrs). The mean duration of non-union was 4.43 yrs (range: 0.5-14 yrs). The mean follow-up period was 33.41 months (range: 12-94 months). The average length of fibula was 10.7 cm (range: 6-15 cm). Main outcome measurements included bony union by radiographic assessment and pre- and postoperative functional evaluation using the DASH (Disabilities of the Arm, Shoulder and Hand) score. Results: Sixteen out of 17 fractures united following revision plating and

  7. Optimisation of composite bone plates for ulnar transverse fractures.

    PubMed

    Chakladar, N D; Harper, L T; Parsons, A J

    2016-04-01

    Metallic bone plates are commonly used for arm bone fractures where conservative treatment (casts) cannot provide adequate support and compression at the fracture site. These plates, made of stainless steel or titanium alloys, tend to shield stress transfer at the fracture site and delay the bone healing rate. This study investigates the feasibility of adopting advanced composite materials to overcome stress shielding effects by optimising the geometry and mechanical properties of the plate to match more closely to the bone. An ulnar transverse fracture is characterised and finite element techniques are employed to investigate the feasibility of a composite-plated fractured bone construct over a stainless steel equivalent. Numerical models of intact and fractured bones are analysed and the mechanical behaviour is found to agree with experimental data. The mechanical properties are tailored to produce an optimised composite plate, offering a 25% reduction in length and a 70% reduction in mass. The optimised design may help to reduce stress shielding and increase bone healing rates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation.

    PubMed

    Lee, J H; Lee, J-H; Park, J W; Shin, Y H

    2012-01-01

    In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis.

  9. Failure analysis of broken pedicle screws on spinal instrumentation.

    PubMed

    Chen, Chen-Sheng; Chen, Wen-Jer; Cheng, Cheng-Kung; Jao, Shyh-Hua Eric; Chueh, Shan-Chang; Wang, Chang-Chih

    2005-07-01

    Revised spinal surgery is needed when there is a broken pedicle screw in the patient. This study investigated the pedicle screw breakage by conducting retrieval analyses of broken pedicle screws from 16 patients clinically and by performing stress analyses in the posterolateral fusion computationally using finite element (FE) models. Fracture surface of screws was studied by scanning electron microscope (SEM). The FE model of the posterolateral fusion with the screw showed that screws on the caudal side had larger axial stress than those on the cephalic side, supporting the clinical findings that 75% of the patients had the screw breakage on the caudal side. SEM fractography showed that all broken screws exhibited beach marks or striations on the fractured surface, indicating fatigue failure. Screws of patients with spinal fracture showed fatigue striations and final ductile fracture around the edge. Among the 16 patients who had broken pedicle screws 69% of them achieved bone union in the bone graft, showing that bone union in the bone graft did not warrant the prevention of screw breakage.

  10. Resorbable versus titanium plates for orthognathic surgery.

    PubMed

    Fedorowicz, Z; Nasser, M; Newton, J T; Oliver, R J

    2007-04-18

    Recognition of some of the limitations of titanium plates and screws used for the fixation of bones has led to the development of plates manufactured from bioresorbable materials. Whilst resorbable plates appear to offer clinical advantages over metal plates in orthognathic surgery, concerns remain about the stability of fixation and the length of time required for their degradation and the possibility of foreign body reactions. To compare the effectiveness of bioresorbable fixation systems with titanium systems used during orthognathic surgery. We searched the following databases: Cochrane Oral Health Group Trials Register (to 26th January 2006); the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2005, Issue 4); MEDLINE (without filter) (from 1966 to 26th January 2006); and EMBASE (without filter) (from 1980 to 26th January 2006). Randomised controlled trials comparing resorbable versus titanium fixation systems used for orthognathic surgery. Clinical heterogeneity between the included trials precluded pooling of data, and only a descriptive summary is presented. This review included two trials, involving 103 participants, one compared titanium with resorbable plates and screws and the other titanium with resorbable screws, both provided very limited data for the primary outcomes of this review. All patients in one trial suffered mild to moderate postoperative discomfort with no statistically significant difference between the two plating groups at different follow-up times. Mean scores of patient satisfaction were 7.43 to 8.63 (range 0 to 10) with no statistically significant difference between the two groups throughout follow up. Adverse effects reported in one study were two plate exposures in each group occurring between the third and ninth months. Plate exposures occurred mainly in the posterior maxillary region, except for one titanium plate exposure in the mandibular premolar region. Known causes of infection were associated

  11. SU-E-T-609: Perturbation Effects of Pedicle Screws On Radiotherapy Dose Distributions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bar-Deroma, R; Borzov, E; Nevelsky, A

    2015-06-15

    Purpose: Radiation therapy in conjunction with surgical implant fixation is a common combined treatment in case of bone metastases. However, metal implants generally used in orthopedic implants perturb radiation dose distributions. Carbon-Fiber Reinforced (CFR) PEEK material has been recently introduced for production of intramedullary screws and plates. Gold powder can be added to the CFR-PEEK material in order to enhance visibility of the screws during intraoperative imaging procedures. In this work, we investigated the perturbation effects of the pedicle screws made of CFR-PEEK, CFR-PEEK with added gold powder (CFR-PEEK-AU) and Titanium (Ti) on radiotherapy dose distributions. Methods: Monte Carlo (MC)more » simulations were performed using the EGSnrc code package for 6MV beams with 10×10 fields at SSD=100cm. By means of MC simulations, dose distributions around titanium, CFR- PEEK and CFR-PEEK-AU screws (manufactured by Carbo-Fix Orthopedics LTD, Israel) placed in a water phantom were calculated. The screw axis was either parallel or perpendicular to the beam axis. Dose perturbation (relative to dose in homogeneous water phantom) was assessed. Results: Maximum overdose due to backscatter was 10% for the Ti screws, 5% for the CFR-PEEK-AU screws and effectively zero for the CFR-PEEK screws. Maximum underdose due to attenuation was 25% for the Ti screws, 15% for the CFR-PEEK-AU screws and 5% for the CFR-PEEK screws. Conclusion: Titanium screws introduce the largest distortion on the radiation dose distribution. The gold powder added to the CFR-PEEK material improves visibility at the cost of increased dose perturbation. CFR-PEEK screws caused minimal alteration on the dose distribution. This can decrease possible over and underdose of adjacent tissue and thus favorably influence treatment efficiency. The use of such implants has potential clinical advantage in the treatment of neoplastic bone disease.« less

  12. Resorbable versus titanium plates for orthognathic surgery.

    PubMed

    Agnihotry, Anirudha; Fedorowicz, Zbys; Nasser, Mona; Gill, Karanjot S

    2017-10-04

    Recognition of some of the limitations of titanium plates and screws used for the fixation of bones has led to the development of plates manufactured from bioresorbable materials. Whilst resorbable plates appear to offer clinical advantages over metal plates in orthognathic surgery, concerns remain about the stability of fixation and the length of time required for their degradation and the possibility of foreign body reactions. This review compares the use of titanium versus bioresorbable plates in orthognathic surgery and is an update of the Cochrane Review first published in 2007. To compare the effects of bioresorbable fixation systems with titanium systems used during orthognathic surgery. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 20 January 2017); the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 11) in the Cochrane Library (searched 20 January 2017); MEDLINE Ovid (1946 to 20 January 2017); and Embase Ovid (1980 to 20 January 2017). We searched the US National Institutes of Health Ongoing Trials Register ClinicalTrials.gov (clinicaltrials.gov; searched 20 January 2017), and the World Health Organization International Clinical Trials Registry Platform (searched 20 January 2017) for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Randomised controlled trials comparing bioresorbable versus titanium fixation systems used for orthognathic surgery in adults. Two review authors independently screened the results of the electronic searches, extracted data and assessed the risk of bias of the included studies. We resolved disagreement by discussion. Clinical heterogeneity between the included trials precluded pooling of data, and only a descriptive summary is presented. This review included two trials, involving 103 participants, one comparing titanium with resorbable plates and screws and

  13. Better Axial Stiffness of a Bicortical Screw Construct Compared to a Cable Construct for Comminuted Vancouver B1 Proximal Femoral Fractures.

    PubMed

    Griffiths, Jamie T; Taheri, Arash; Day, Robert E; Yates, Piers J

    2015-12-01

    The aim of this study was to biomechanically evaluate the Locking attachment plate (LAP) construct in comparison to a Cable plate construct, for the fixation of periprosthetic femoral fractures after cemented total hip arthroplasty. Each construct incorporated a locking compression plate with bi-cortical locking screws for distal fixation. In the Cable construct, 2 cables and 2 uni-cortical locking screws were used for proximal fixation. In the LAP construct, the cables were replaced by a LAP with 4 bi-cortical locking screws. The LAP construct was significantly stiffer than the cable construct under axial load with a bone gap (P=0.01). The LAP construct offers better axial stiffness compared to the cable construct in the fixation of comminuted Vancouver B1 proximal femoral fractures. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  14. Plantar Plating for the Treatment of Proximal Fifth Metatarsal Fractures in Elite Athletes.

    PubMed

    Mitchell, Ronald J; Duplantier, Neil L; Delgado, Domenica A; Lambert, Bradley S; McCulloch, Patrick C; Harris, Joshua D; Varner, Kevin E

    2017-05-01

    Proximal fifth metatarsal fractures, zones II and III, are commonly treated surgically, especially in elite athletes. Intramedullary screw fixation remains the most used construct despite nonunion and refracture. High tensile forces on the plantar-lateral aspect of the fifth metatarsal are difficult to control, and intramedullary screw fixation depends on ideal screw position, length, and width. The authors present a plantar plating technique with cancellous bone autograft for zones II and III proximal fifth metatarsal fractures. Rotational instability and plantar-lateral gapping are resisted by applying a compression plate to the tension side of the fracture, eliminating causes for failure. [Orthopedics. 2017; 40(3):e563-e566.]. Copyright 2017, SLACK Incorporated.

  15. Reconstruction of Canine Mandibular Bone Defects Using a Bone Transport Reconstruction Plate

    PubMed Central

    Elsalanty, Mohammed E.; Zakhary, Ibrahim; Akeel, Sara; Benson, Byron; Mulone, Timothy; Triplett, Gilbert R.; Opperman, Lynne A.

    2010-01-01

    Objectives Reconstruction of mandibular segmental bone defects is a challenging task. This study tests a new device used for reconstructing mandibular defects based on the principle of bone transport distraction osteogenesis. Methods Thirteen beagle dogs were divided into control and experimental groups. In all animals, a 3 cm defect was created on one side of the mandible. In eight control animals, the defect was stabilized with a reconstruction plate without further reconstruction and the animals were sacrificed two to three months after surgery. The remaining five animals were reconstructed with a bone transport reconstruction plate (BTRP), comprising a reconstruction plate with attached intraoral transport unit, and were sacrificed after one month of consolidation. Results Clinical evaluation, cone-beam CT densitometry, three-dimensional histomorphometry, and docking site histology revealed significant new bone formation within the defect in the distracted group. Conclusion The physical dimensions and architectural parameters of the new bone were comparable to the contralateral normal bone. Bone union at the docking site remains a problem. PMID:19770704

  16. State Recognition of Bone Drilling Based on Acoustic Emission in Pedicle Screw Operation.

    PubMed

    Guan, Fengqing; Sun, Yu; Qi, Xiaozhi; Hu, Ying; Yu, Gang; Zhang, Jianwei

    2018-05-09

    Pedicle drilling is an important step in pedicle screw fixation and the most significant challenge in this operation is how to determine a key point in the transition region between cancellous and inner cortical bone. The purpose of this paper is to find a method to achieve the recognition for the key point. After acquiring acoustic emission (AE) signals during the drilling process, this paper proposed a novel frequency distribution-based algorithm (FDB) to analyze the AE signals in the frequency domain after certain processes. Then we select a specific frequency domain of the signal for standard operations and choose a fitting function to fit the obtained sequence. Characters of the fitting function are extracted as outputs for identification of different bone layers. The results, which are obtained by detecting force signal and direct measurement, are given in the paper. Compared with the results above, the results obtained by AE signals are distinguishable for different bone layers and are more accurate and precise. The results of the algorithm are trained and identified by a neural network and the recognition rate reaches 84.2%. The proposed method is proved to be efficient and can be used for bone layer identification in pedicle screw fixation.

  17. [Biodegradable screw versus a press-fit bone plug fixation for ACL reconstruction: a prospective randomized study].

    PubMed

    Geiges, B; von Falck, C; Knobloch, K; Haasper, C; Meller, R; Krettek, C; Hankemeier, S; Brand, J; Jagodzinski, M

    2013-02-01

    Press-fit fixation of a tendon graft has been advocated in order to achieve tendon to bone healing. Fixation of a tendon graft with a porous bone scaffold limits bone tunnel enlargement compared with a biodegradable interference screw fixation. Between 2005 and 2006, 20 patients (17 men, 3 women) were enrolled in this study for primary reconstruction of the ACL. Patients were randomized to either obtain graft fixation in the tibial tunnel by means of an interference screw (I) or a press-fit fixation with a porous bone cylinder (P). Three months after surgery, a CT scan of the knee was performed and tunnel enlargement was analysed in the coronal and sagittal planes for the proximal, middle and distal thirds of the tunnel. After 6 months, 1 and 2 years, International Knee Documentation Committee (IKDC), Tegner and Lysholm scores of both groups were compared. The bone tunnel enlargement was 106.9±10.9% for group P and 121.9±9.0% for group I (P<0.02) in the AP plane and 102.8±15.2% vs 121.5±10.1% in the coronal plane (P<0.01). IKDC, Tegner, and Lysholm scores improved in both groups from pre- to postoperative assessment without significant differences between the two groups. There was a trend to higher knee stability in group P after 3 months (0.6±1.4 mm vs 1.81±.5 mm, P=0.08). Both interference screw and a press-fit fixation lead to a high number of good or very good outcomes after ACL reconstruction. Tibial press-fit fixation decreases the amount of proximal bone tunnel enlargement. Press-fit fixation decreases the amount of proximal bone tunnel enlargement and improves bone to tendon contact.

  18. Biomechanical in vitro - stability testing on human specimens of a locking plate system against conventional screw fixation of a proximal first metatarsal lateral displacement osteotomy.

    PubMed

    Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah

    2012-01-01

    The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability.

  19. Pelvic modelling and the comparison between plate position for double pelvic osteotomy using artificial cancellous bone and finite element analysis.

    PubMed

    McCartney, William; MacDonald, Bryan; Ober, Ciprian Andrei; Lostado-Lorza, Rubén; Gómez, Fátima Somovilla

    2018-03-20

    Finite element analysis was used to compare fixation methods for double pelvic osteotomy (DPO). Using 3D scanning a stereolithography (stl) image was produced of a canine pelvis and this was subsequently refined in computer aided design (CAD). Using the CAD files, the images were imported in MSC Marc software to produce a working finite element (FE) model with 3 dimensional tetrahedral elements with linear shaped functions. The dimensions of a precontoured pelvic osteotomy plate with eight screws and a twisted seven screw straight plate were used to build the 2 fixations implants for the FE models. An equivalent load of 300 N was applied progressively on all FE models in order to facilitate its convergence. The load was applied in a distributed manner on the femur-hip joint contact area in order to simulate the actual behavior of the joint. The aim of the present study was to analyze the difference in stiffness and behavior under loading between a lateral vs ventral plate fixation, with unlocked screws and different gap scenarios, for stabilization of a pelvic osteotomy using finite element analysis. From both configurations the maximum displacement of the ventral plate with 7 screws without gap had a value of 1.988 mm, while in the DPO plate had a maximum displacement of 2.191 mm. The load applied for each of the different configurations studied when a gap of 1° was considered and also when a condition of no gap was considered. The ventral plate was stiffer than the lateral plate when a gap was not present. When the gap was closed in the ventral plate, the stiffness increased until a point that remained constant. Ventral plate fixation can be as or more stiff as lateral plate fixation and provides flexible fixation. This behavior should reduce screw loosening. Using ventral plate fixation is recommended to reduce screw loosening or failure.

  20. A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures.

    PubMed

    Patil, Sunit; Mahon, Andrew; Green, Sarah; McMurtry, Ian; Port, Andrew

    2006-06-01

    There has been a recent trend towards using a raft of small diameter 3.5mm cortical screws for supporting depressed tibial plateau fractures (Schatzker type III). Our aim was to compare the biomechanical properties of a raft of 3.5 mm cortical screws with that of 6.5 mm cancellous screws in a synthetic bone model. Ten rigid polyurethane foam (sawbone) blocks, with a density simulating osteoporotic bone and ten blocks with a density simulating normal density bone were obtained. A Schatzker type III fracture was created in each block. The fracture fragments were then elevated and supported using two 6.5 mm cancellous screws in ten blocks and four 3.5 mm cortical screws in the remaining. The fractures were loaded using a Lloyd testing machine. The mean force needed to produce a depression of 5 mm was 700.8 N with the four-screw construct and 512.4 N with the two-screw construct in the osteoporotic model. This difference was highly statistically significant (p = 0.009). The mean force required to produce the same depression was 1878.2 N with the two-screw construct and 1938.2 N with the four-screw construct in the non-osteoporotic model. Though the difference was not statistically significant (p = 0.42), an increased fragmentation of the synthetic bone fragments was noticed with the two-screw construct but not with the four-screw construct. A raft of four 3.5 mm cortical screws is biomechanically stronger than two 6.5 mm cancellous screws in resisting axial compression in osteoporotic bone.

  1. Influence of the osteosynthesis plate on ultrasound propagation in the bone

    PubMed Central

    Bezuti, Márcio Takey; Mandarano-Filho, Luiz Garcia; Barbieri, Giuliano; Mazzer, Nilton; Barbieri, Cláudio Henrique

    2014-01-01

    Objective: To analyze the influence of steel plates for osteosynthesis on the velocity of ultrasound propagation (VU) through the bone. Methods: The transverse coronal and sagittal velocity of ultrasound propagation underwater were measured on the intact bone and then on assemblies of the same bone with two types of osteosynthesis plates (DCP and semi tubular), fixed onto the dorsal side of the bones. The first arriving signal (FAS) was the ultrasound parameter used, taking the coronal and sagittal diameters as the distances to calculate velocity. Intergroup statistical comparisons were made at significance level of 1% (p<0.01). Results: Velocity was higher on the intact bones than on the bone-plate assemblies and higher for the semitubular than for the compression plates, although differences were not statistically significant for most comparisons (p=0.0132 to 0.9884), indicating that the steel plates do not interfere significantly with ultrasound wave propagation through the bone-plate assemblies. Conclusion: The velocity reduction effect was attributed to the greater reflection coefficient of the steel as compared to that of bone and water. Ultrasonometry can, thus, be used in the evaluation of healing of fractures fixed with steel plates. Experimental Study. PMID:25328436

  2. In Vitro and In Vivo Evaluations of Nano-Hydroxyapatite/Polyamide 66/Glass Fibre (n-HA/PA66/GF) as a Novel Bioactive Bone Screw

    PubMed Central

    Su, Bao; Peng, Xiaohua; Jiang, Dianming; Wu, Jun; Qiao, Bo; Li, Weichao; Qi, Xiaotong

    2013-01-01

    In this study, we prepared nano-hydroxyapatite/polyamide 66/glass fibre (n-HA/PA66/GF) bioactive bone screws. The microstructure, morphology and coating of the screws were characterised, and the adhesion, proliferation and viability of MC3T3-E1 cells on n-HA/PA66/GF scaffolds were determined using scanning electron microscope, CCK-8 assays and cellular immunofluorescence analysis. The results confirmed that n-HA/PA66/GF scaffolds were biocompatible and had no negative effect on MC3T3-E1 cells in vitro. To investigate the in vivo biocompatibility, internal fixation properties and osteogenesis of the bioactive screws, both n-HA/PA66/GF screws and metallic screws were used to repair intercondylar femur fractures in dogs. General photography, CT examination, micro-CT examination, histological staining and biomechanical assays were performed at 4, 8, 12 and 24 weeks after operation. The n-HA/PA66/GF screws exhibited good biocompatibility, high mechanical strength and extensive osteogenesis in the host bone. Moreover, 24 weeks after implantation, the maximum push-out load of the bioactive screws was greater than that of the metallic screws. As shown by their good cytocompatibility, excellent biomechanical strength and fast formation and ingrowth of new bone, n-HA/PA66/GF screws are thus suitable for orthopaedic clinical applications. PMID:23861888

  3. Magnesium Alloys as a Biomaterial for Degradable Craniofacial Screws

    PubMed Central

    Henderson, Sarah E.; Verdelis, Konstantinos; Maiti, Spandan; Pal, Siladitya; Chung, William L.; Chou, Da-Tren; Kumta, Prashant N.; Almarza, Alejandro J.

    2014-01-01

    Recently, magnesium (Mg) alloys have received significant attention as a potential biomaterial for degradable implants, and this study was directed at evaluating the suitability of Mg for craniofacial bone screws. The objective was to implant screws fabricated from commercially available Mg-alloys (pure Mg and AZ31) in-vivo in a rabbit mandible. First, Mg-alloy screws were compared to stainless steel screws in an in-vitro pull-out test and determined to have a similar holding strength (~40N). A finite element model of the screw was created using the pull-out test data, and the model can be used for future Mg-alloy screw design. Then, Mg-alloy screws were implanted for 4, 8, and 12 weeks, with two controls of an osteotomy site (hole) with no implant and a stainless steel screw implanted for 12 weeks. MicroCT (computed tomography) was used to assess bone remodeling and Mg-alloy degradation, both visually and qualitatively through volume fraction measurements for all time points. Histologic analysis was also completed for the Mg-alloys at 12 weeks. The results showed that craniofacial bone remodeling occurred around both Mg-alloy screw types. Pure Mg had a different degradation profile than AZ31, however bone growth occurred around both screw types. The degradation rate of both Mg-alloy screw types in the bone marrow space and the muscle were faster than in the cortical bone space at 12 weeks. Furthermore, it was shown that by alloying Mg, the degradation profile could be changed. These results indicate the promise of using Mg-alloys for craniofacial applications. PMID:24384125

  4. Biomechanical In Vitro - Stability Testing on Human Specimens of a Locking Plate System Against Conventional Screw Fixation of a Proximal First Metatarsal Lateral Displacement Osteotomy

    PubMed Central

    Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah

    2012-01-01

    Introduction: The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Materials and Methodology: Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. Results: We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. Conclusion: The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability. PMID:22675409

  5. Effect of various factors on pull out strength of pedicle screw in normal and osteoporotic cancellous bone models.

    PubMed

    Varghese, Vicky; Saravana Kumar, Gurunathan; Krishnan, Venkatesh

    2017-02-01

    Pedicle screws are widely used for the treatment of spinal instability by spine fusion. Screw loosening is a major problem of spine fusion, contributing to delayed patient recovery. The present study aimed to understand the factor and interaction effects of density, insertion depth and insertion angle on pedicle screw pull out strength and insertion torque. A pull out study was carried out on rigid polyurethane foam blocks representing osteoporotic to normal bone densities according to the ASTM-1839 standard. It was found that density contributes most to pullout strength and insertion torque. The interaction effect is significant (p < 0.05) and contributes 8% to pull out strength. Axial pullout strength was 34% lower than angled pull out strength in the osteoporotic bone model. Insertion angle had no significant effect (p > 0.05) on insertion torque. Pullout strength and insertion torque had no significant correlation (p > 0.05) in the case of the extremely osteoporotic bone model. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Condylar Joint Fusion and Stabilization (by Screws and Plates) in Nontraumatic Atlanto-Occipital Dislocation: Technical Report of 2 Cases.

    PubMed

    Chowdhury, Forhad H; Haque, Mohammod Raziul; Alam, Sarwar Murshed; Khaled Chowdhury, S M Noman; Khan, Shamsul Islam; Goel, Atul

    2017-11-01

    Nontraumatic spontaneous atlanto-occipital dislocation (AOD) is rare. In this report, we discuss the technical steps of condylar joint fusion and stabilization (by screws and plates) in nontraumatic AOD. To the best of our knowledge, it is the first report of such techniques. A young girl and a young man with progressive quadriparesis due to nontraumatic spontaneous atlanto-occipital dislocation were managed by microsurgical reduction, fusion, and stabilization of the joint by occipital condylar and C1 lateral mass screw and plate fixation after mobilization of vertebral artery. In both cases, condylar joints fixation and fusion were done successfully. Condylar joint stabilization and fusion may be a good or alternative option for AOD. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Testing Pullout Strength of Pedicle Screw Using Synthetic Bone Models: Is a Bilayer Foam Model a Better Representation of Vertebra?

    PubMed

    Varghese, Vicky; Krishnan, Venkatesh; Saravana Kumar, Gurunathan

    2018-06-01

    A biomechanical study. A new biomechanical model of the vertebra has been developed that accounts for the inhomogeneity of bone and the contribution of the pedicle toward the holding strength of a pedicle screw. Pullout strength studies are typically carried out on rigid polyurethane foams that represent the homogeneous vertebral framework of the spine. However, the contribution of the pedicle region, which contributes to the inhomogeneity in this framework, has not been considered in previous investigations. Therefore, we propose a new biomechanical model that can account for the vertebral inhomogeneity, especially the contribution of the pedicles toward the pullout strength of the pedicle screw. A bilayer foam model was developed by joining two foams representing the pedicle and the vertebra. The results of the pullout strength tests performed on the foam models were compared with those from the tests performed on the cadaver lumbar vertebra. Significant differences ( p <0.05) were observed between the pullout strength of the pedicle screw in extremely osteoporotic (0.18±0.11 kN), osteoporotic (0.37±0.14 kN), and normal (0.97±0.4 kN) cadaver vertebra. In the monolayer model, significant differences ( p <0.05) were observed in pullout strength between extremely osteoporotic (0.3±0.02 kN), osteoporotic (0.65±0.12 kN), and normal (0.99±0.04 kN) bone model. However, the bilayer foam model exhibited no significant differences ( p >0.05) in the pullout strength of pedicle screws between osteoporotic (0.85±0.08 kN) and extremely osteoporotic bone models (0.94±0.08 kN), but there was a significant difference ( p <0.05) between osteoporotic (0.94±0.08 kN) and normal bone models (1.19±0.05 kN). There were no significant differences ( p >0.05) in pullout strength between cadaver and bilayer foam model in normal bones. The new synthetic bone model that reflects the contribution of the pedicles to the pullout strength of the pedicle screws could provide a more

  8. Systematic review of cortical bone trajectory versus pedicle screw techniques for lumbosacral spine fusion.

    PubMed

    Phan, Kevin; Ramachandran, Vignesh; Tran, Tommy M; Shah, Kevin P; Fadhil, Matthew; Lackey, Alan; Chang, Nicholas; Wu, Ai-Min; Mobbs, Ralph J

    2017-12-01

    Fusion of the lumbosacral spine is a common surgical procedure to address a range of spinal pathologies. Fixation in lumbar fusion has traditionally been performed using pedicle screw (PS) augmentation. However, an alternative method of screw insertion via cortical bone trajectory (CBT) has been advocated as a less invasive approach which improves initial fixation and reduces neurovascular injury. There is a paucity of robust clinical evidence to support these claims, particularly in comparison to traditional pedicle screws. This study aims to review the available evidence to assess the merits of the CBT approach. Six electronic databases were searched for original published studies which compared CBT with traditional PS and their findings reviewed. Nine comparative studies were identified through a comprehensive literature search. Studies were classified as retrospective cohort, prospective cohort or case control studies with medium quality as assessed by the GRADE criteria. The available literature is not cohesive regarding outcomes and complications of CBT versus PT procedures. Most studies found no difference in operative time, but reported less blood loss during CBT. Radiological outcomes show no difference in slippage at one year although CBT is associated with greater bone-density compared to PT. Results for post-operative pain are inconclusive.

  9. [Tensile strength of bone fixation of hydroxyapatite coated Schanz screws of the Heidelberg External Fixation System (HEFS)--comparative torque measurements in clinical use and in cadaver tibia].

    PubMed

    Placzek, R; Deuretzbacher, G; Meiss, A L

    2002-12-01

    It is claimed in the literature that hydroxyapatite(HA)-coated screws of external fixators have superior fixation strength in bone, which is postulated to lead to a substantial decrease in loosening and infection rates. We report on a study of the maximum torque values developed while inserting and removing 30 HA-coated Schanz screws of 8 Heidelberg external fixation systems applied to the tibia to correct leg length differences and axial deformities. The infection rate was determined in accordance with defined criteria, and was found to be about 20% for the HA-coated screws. Screws without infection showed an extraction torque above insertion torque, screws with infection an extraction torque below. A significant correlation (p = 0.05) was seen between infection and decrease in fixation strength (quotient: loosening torque/tightening torque). To exclude the impact of such biological processes as osteointegration and bone remodelling, the clinical results were compared with the torques measured for coated and uncoated Schanz screws in a human cadaveric tibia. A significantly higher fixation strength in bone was found for HA-coated screws in comparison with uncoated screws (p = 0.002). These data warrant a clinical study directly comparing HA-coated and uncoated Schanz screws.

  10. Bone response to collagenized xenografts of porcine origin (mp3(®) ) and a bovine bone mineral grafting (4BONE(™) XBM) grafts in tibia defects: experimental study in rabbits.

    PubMed

    Calvo-Guirado, José Luis; Aguilar-Salvatierra, Antonio; Ramírez-Fernández, Maria P; Maté Sánchez de Val, José E; Delgado-Ruiz, Rafael Arcesio; Gómez-Moreno, Gerardo

    2016-08-01

    This study aimed to carry out the evaluation of bone response of new bone formation to two different xenografts (bovine and porcine) biomaterials inserted in rabbit tibiae. The study used a total of 20 male New Zealand albino rabbits. They received a total of 40 grafts in the proximal metaphyseal areas of both tibiae. Two biomaterials were evaluated: 20 porcine xenografts, as a bone granulate (OsteoBiol(®) MP3(®) ; Tecnoss srl, Giaveno, Italy), were placed in the proximal metaphyseal area of the right tibia, 20 anorganic bovine bone mineral grafting (4BONE(™) XBM, MIS Implants Inc., BARLEV, Israel) were placed in the left tibia. Following graft insertion, the animals were sacrificed in two groups of 10 animals, after 1 and 4 months, respectively. For each group, biomaterials were analyzed: newly formed bone, residual graft materials and the connective tissue. Histomorphometric, EDX analysis and element mapping were performed at 1 and 4 months after graft insertion. At 4 months after treatment, the bone defects displayed radiological images that showed complete repair of osseous defects. Histomorphometric evaluation showed that for the porcine xenograft, the study averages for newly formed bone represented 84.23 ± 2.9%, while bovine matrix was 79.34 ± 2.1%. For residual graft material, the porcine biomaterial had 11.23 ± 1.7% and the bovine graft 31.56 ± 2.3%. Finally, the connective tissue for MP3 was 10.33 ± 1.8%, while for the 4BONE(™) XBM we obtained 14.34 ± 2.9%. Element analysis revealed higher percentages of Ca (54 ± 9%) and P (35 ± 6%) in the group B than group A and control group (P < 0.05). Defects of a critical size in a rabbit tibia model can be sealed using a bovine porous biphasic calcium phosphate and MP3 material; this supports new bone formation, creates a bridge between borders, and facilitates bone ingrowth in both biomaterials. Furthermore, this study observed partial dissolution of the mineral phase of four

  11. Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.

    PubMed

    Yang, Jesse Chieh-Szu; Chen, Hsin-Chang; Lai, Yu-Shu; Cheng, Cheng-Kung

    2017-01-01

    Fixation with a dynamic hip screw (DHS) is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw') to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (≥10 mm) before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p ≤ 0.03). Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12). However, the patient's implanted with a DHS did display significantly greater migration (P<0.001) than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.

  12. Clinical comparative analysis on unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation.

    PubMed

    Li, C-L

    2014-01-01

    To investigate clinical efficacy of unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation. 64 patients with unstable pelvic fractures were selected in the hospital from January 2008 to June 2011, and were randomly divided into two groups.(32 patients with sacroiliac anterior plate fixation as the control group, and another 32 patients with percutaneous sacroiliac screw internal fixation as the observation group). The perioperative period clinical indicators, postoperative Matta score, postoperative Majeed function score of all patients were compared and analyzed. The operation time, intraoperative blood loss, wound total length, postoperative fever time, duration of hospitalization in the observation group were significantly less than those in the control group. The complication rate (3.1%) in the observation group was lower than that in the control group (21.9%). The rate of Matta score excellent (96.9%) in the observation group was higher than that in the control group (81.2%) after the treatment. The rate of Majeed function score excellent (93.8%) in the observation group was significantly higher than that in the control group (75%) after the treatment. Percutaneous sacroiliac screw internal fixation in the treatment of unstable pelvic fractures has less injury, less bleeding, less pain and rapid recovery which is a safe and effective minimally invasive operation method. The clinical curative effect of percutaneous sacroiliac screw internal fixation is better than anterior plate fixation for the treatment of sacroiliac joint. The full preparation before the surgery and patients with positive can substantially reduce the occurrence of complications rate.

  13. [APPLICATION OF COMPRESSION MINI-SCREWS IN TREATMENT OF PATIENTS WITH INJURY OF ELBOW JOINT BONES].

    PubMed

    Neverov, V A; Egorov, K S

    2015-01-01

    A case report presents the experience of application of compression pileateless mini-screws (Gerbert's screws) in treatment of intra-articular fractures, which formed the elbow joint (44 cases). There were performed 32 operations concerning fracture of head of radius, 10 operations on the occasion of fractures of distal section of the humerus and 2 operations on the coronoid process. Long-term treatment results were followed-up in 31 patients during more than 6 months. On basis of analysis of treatment results the authors made a conclusion that the application of mini-screws in case of bone fractures, which formed the elbow joint, allowed realization of stable osteosynthesis after anatomic reposition of articular surfaces, obtaining good anatomical and functional result and shortened the terms of patient's treatment.

  14. Anterior cervical pedicle screw and plate fixation using fluoroscope-assisted pedicle axis view imaging: a preliminary report of a new cervical reconstruction technique

    PubMed Central

    Kato, Fumihiko; Ito, Keigo; Nakashima, Hiroaki; Machino, Masaaki

    2009-01-01

    Anterior procedures in the cervical spine are feasible in cases having anterior aetiologies such as anterior neural compression and/or severe kyphosis. Halo vests or anterior plates are used concurrently for cases with long segmental fixation. Halo vests are bothersome and anterior plate fixation is not adequately durable. We developed a new anterior pedicle screw (APS) and plate fixation procedure that can be used with fluoroscope-assisted pedicle axis view imaging. Six patients (3 men and 3 women; mean age, 54 years) with anterior multisegmental aetiology were included in this study. Their original diagnoses comprised cervical myelopathy and/or radiculopathy (n = 4), posterior longitudinal ligament ossification (n = 1) and post-traumatic kyphosis (n = 1). All patients underwent anterior decompression and strut grafting with APS and plate fixation. Mean operative time was 192 min and average blood loss was 73 ml. Patients were permitted to ambulate the next day with a cervical collar. Local sagittal alignment was characterised by 3.5° of kyphosis preoperatively, which improved to 6.8° of lordosis postoperatively and 5.2° of lordosis at final follow-up. Postoperative improvement and early bony union were observed in all cases. There was no serious complication except for two cases of dysphagia. Postoperative imaging demonstrated screw exposure in one screw, but no pedicle perforation. APS and plate fixation is useful in selected cases of multisegmental anterior reconstruction of cervical spine. However, the adequate familiarity and experience with both cervical pedicle screw fixation and the imaging technique used for visualising the pedicle during surgery are crucial for this procedure. PMID:19343377

  15. Comparison of Expansive Pedicle Screw and Polymethylmethacrylate-Augmented Pedicle Screw in Osteoporotic Sheep Lumbar Vertebrae: Biomechanical and Interfacial Evaluations

    PubMed Central

    Zhang, Bo; Xie, Qing-yun; Wang, Cai-ru; Liu, Jin-biao; Liao, Dong-fa; Jiang, Kai; Lei, Wei; Pan, Xian-ming

    2013-01-01

    Background It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. Methodology/Principal Findings After successful induction of osteoporotic sheep, lumbar vertebrae in each sheep were randomly divided into three groups. The conventional pedicle screw (CPS) was inserted directly into vertebrae in CPS group; PMMA was injected prior to insertion of CPS in PMMA-PS group; and the EPS was inserted in EPS group. Sheep were killed and biomechanical tests, micro-CT analysis and histological observation were performed at both 6 and 12 weeks post-operation. At 6-week and 12-week, screw stabilities in EPS and PMMA-PS groups were significantly higher than that in CPS group, but there were no significant differences between EPS and PMMA-PS groups at two study periods. The screw stability in EPS group at 12-week was significantly higher than that at 6-week. The bone trabeculae around the expanding anterior part of EPS were more and denser than that in CPS group at 6-week and 12-week. PMMA was found without any degradation and absorption forming non-biological “screw-PMMA-bone” interface in PMMA-PS group, however, more and more bone trabeculae surrounded anterior part of EPS improving local bone quality and formed biological “screw-bone” interface. Conclusions/Significance EPS can markedly enhance screw stability with a similar effect to the traditional method of screw augmentation with PMMA in initial surgery in osteoporosis. EPS can form better biological interface between screw and bone than PMMA-PS. In addition, EPS have no risk of thermal injury, leakage and compression caused by PMMA. We propose EPS has a great application potential in augmentation of screw stability

  16. Bone Plating in Patients with Type III Osteogenesis Imperfecta: Results and Complications

    PubMed Central

    Enright, William J; Noonan, Kenneth J

    2006-01-01

    The results of bone plating in four children (6 femurs, 2 tibias) with osteogenesis imperfecta type III were analyzed. Average age at time of operation was 44 months. In three of the femurs, multiple platings were performed for a total of 13 bone platings in the eight bones studied. Average time to revision following plating was 27 months. Indications for revision included fracture (6), deformity (3), hardware failure (3), and nonunion (1). Other complications included one case of compartment syndrome. All eight bones were ultimately revised to elongating intramedullary Bailey-Dubow rods. Bone plating in skeletally immature patients with osteogenesis imperfecta does not provide better outcome than elongating rods. Complications from bone plating leading to revision, such as refracture or hardware failure, are higher than in those children managed with elongating rods, as previously reported in the literature. PMID:16789446

  17. Stress analysis of implant-bone fixation at different fracture angle

    NASA Astrophysics Data System (ADS)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, MS Abdul; Zain, N. A. M.; Bajuri, Y.

    2017-10-01

    Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.

  18. Absorbable screws through the greater trochanter do not disturb physeal growth: rabbit experiments.

    PubMed

    Gil-Albarova, J; Fini, M; Gil-Albarova, R; Melgosa, M; Aldini-Nicolo, N; Giardino, R; Seral, F

    1998-06-01

    We studied the effect of implantation of self-reinforced polyglycolic acid (SR-PGA) screws through the greater trochanter in rabbits. 15 rabbits aged 10 weeks had an SR-PGA screw inserted through the left trochanter physis. A similar drilling was made through the right greater trochanter without screw implantation. The animals were assigned to 3 groups of 5, and were killed after 1, 2 or 3 months. Radiographs of both femurs were obtained monthly and the articulo-trochanteric distance and the neck-shaft angle were measured. After killing the animals, a histological study was performed. The drilling on the right trochanter generated a bony bridge in all the animals. The SR-PGA screws did not give rise to an epiphysiodesis. The progressive peripheral degradation of the implants gave rise to the formation of only modest bridges, which were smaller in size than those observed in the control trochanter. Our findings suggest that absorbable PGA screws implanted through a growth plate cause only minor bone formation and no epiphyseodesis.

  19. [Use of pedicle percutaneous cemented screws in the management of patients with poor bone stock].

    PubMed

    Pesenti, S; Graillon, T; Mansouri, N; Adetchessi, T; Tropiano, P; Blondel, B; Fuentes, S

    2016-12-01

    Management of patients with poor bone stock remains difficult due to the risks of mechanical complications such as screws pullouts. At the same time, development of minimal invasive spinal techniques using a percutaneous approach is greatly adapted to these fragile patients with a reduction in operative time and complications. The aim of this study was to report our experience with cemented percutaneous screws in the management of patients with a poor bone stock. Thirty-five patients were included in this retrospective study. In each case, a percutaneous osteosynthesis using cemented screws was performed. Indications were osteoporotic fractures, metastasis or fractures on ankylosing spine. Depending on radiologic findings, short or long constructs (2 levels above and below) were performed and an anterior column support (kyphoplasty or anterior approach) was added. Evaluation of patients was based on pre and postoperative CT-scans associated with clinical follow-up with a minimum of 6 months. Eleven men and 24 women with a mean age of 73 years [60-87] were included in the study. Surgical indication was related to an osteoporotic fracture in 20 cases, a metastasis in 13 cases and a fracture on ankylosing spine in the last 2 cases. Most of the fractures were located between T10 and L2 and a long construct was performed in 22 cases. Percutaneous kyphoplasty was added in 24 cases and a complementary anterior approach in 3 cases. Average operative time was 86minutes [61-110] and blood loss was estimated as minor in all the cases. In the entire series, average volume of cement injected was 1.8 cc/screw. One patient underwent a major complication with a vascular leakage responsible for a cement pulmonary embolism. With a 9 months average follow-up [6-20], no cases of infection or mechanical complication was reported. Minimal invasive spinal techniques are greatly adapted to the management of fragile patients. The use of percutaneous cemented screws is, in our experience

  20. Displaced Neer Type IIB distal-third clavicle fractures-Long-term clinical outcome after plate fixation and additional screw augmentation for coracoclavicular instability.

    PubMed

    Tiefenboeck, Thomas M; Boesmueller, Sandra; Binder, Harald; Bukaty, Adam; Tiefenboeck, Michael M; Joestl, Julian; Hofbauer, Marcus; Ostermann, Roman C

    2017-01-23

    Unstable Neer Type IIB fractures require meticulous surgical treatment. Thus, the aim of this study was to present long-term outcomes after plate fixation and minimally invasive coracoclavicular (CC) stabilization using screw fixation. A consecutive series of patients with unstable Neer Type IIB displaced clavicle fractures, treated by open reduction and internal fixation (ORIF) with a plate and additional screw fixation for coracoclavicular ligament instability, was reviewed in order to determine long-term clinical and radiological outcome. Seven patients, six males and one female, with a mean age of 37 ± 8 years (median: 36 years; range, 28-51 years), were evaluated. At latest follow-up, after a mean of 67 months (range, 11-117 months), patients presented with the following mean scores: DASH: 0.57, ASES: 98.81, UCLA: 34.29, VAS: 0.43, Simple Shoulder Test: 11.57. However, two complications were observed: one case of implant loosening and one non-union. There were no differences observed between the CC distances comparing postoperative X-rays to those in final follow-up. In 25% of our patients early postoperative complications occurred. In all patients reoperation was necessary to remove the implanted screw. The results of the present study indicate that the treatment of Neer Type IIB lateral clavicle fractures with ORIF using a plate and additional CC screw fixation, leads to satisfying clinical and radiological outcomes in the long-term. However, considering an early postoperative complication rate of 25% and a 100% rate of secondary surgery due to removal of the CC screw does not seem to justify this technique anymore.

  1. Mineralisation and mechanical strength of the glenoid cavity subchondral bone plate.

    PubMed

    Kraljević, Marko; Zumstein, Valentin; Wirz, Dieter; Hügli, Rolf; Müller-Gerbl, Magdalena

    2011-12-01

    Failures in total shoulder replacements are often due to aseptic loosening of the glenoid component; the subchondral bone plate is an important factor governing primary fixation of implant materials. Therefore, we investigated characteristic mineralisation patterns of the subchondral bone plate, which demonstrate long-term stress on articular surfaces, age-related changes, postsurgical biomechanical situations and regions of fixation. Using computed tomography osteo-absorptiometry (CT-OAM), these distribution patterns can be demonstrated in vivo. The aim of this study was to investigate the relationship between subchondral bone-plate mineralisation measured with CT-OAM and the mechanical strength measured by indentation. A total of 32 cadaverous glenoid cavities were evaluated by CT-OAM and indentation testing. Linear regression was used to compare mineralisation and strength of the subchondral bone plate. Results showed two patterns of mineralisation distribution. Twenty-eight cavities were related to bicentric distribution pattern and four showed a single maximum. The correlation coefficient between CT-OAM density and subchondral bone-plate strength was determined to be between 0.62 and 0.96 (P < 0.02). Long-term stress affects not only the subchondral but also the underlying cancellous bone. It therefore can be assumed that mineralisation patterns of the subchondral bone plate continue in cancellous bone. Areas of high density could serve as anchoring locations for orthopaedic implants in resurfacing the glenoid cavity.

  2. Long-term absorption of poly-L-lactic Acid interference screws.

    PubMed

    Barber, F Alan; Dockery, W Dee

    2006-08-01

    To evaluate the long term in vivo degradation of poly-L-lactic acid (PLLA) interference screws with computed tomography (CT) and radiography as used in patellar tendon autograft anterior cruciate ligament (ACL) reconstruction. A total of 20 patients who had undergone patellar tendon autograft ACL reconstruction fixed with PLLA screws at least 7 years earlier were evaluated by physical examination, radiography, and CT to determine whether PLLA screw reabsorption and bone ingrowth had occurred. This study was granted Institutional Review Board approval. Lysholm, Tegner, Cincinnati, and International Knee Documentation Committee (IKDC) scores were obtained. CT data were measured in Hounsfield units. In all, 15 men and 5 women were evaluated 104 months after surgery (range, 89 to 124 months). CT and radiography demonstrated that the bone plug had fused to the tunnel wall, and that no intact interference screw was left. A parallel, threaded, and corticated screw tract was visible adjacent to the bone plug. No bone ingrowth had occurred at the screw site, although, occasionally, minimal calcification was seen. This was never as dense as cancellous bone, and no trabeculae were ever present. No positive pivot-shift test results were obtained. Lysholm, Tegner, and Cincinnati scores were 83, 5.6, and 75, respectively, at follow-up. Average KT difference was 0.7 mm. PLLA interference screws completely degraded, and the resulting area demonstrated a low Hounsfield count, consistent with soft tissue 7 years after insertion. No significant bone ingrowth occurred at the screw site. Femoral and tibial ACL tunnels were absent of anything but fibrous tissue and usually had a sclerotic cortical lining. PLLA biodegradable ACL screws eventually disappear completely. PLLA material is not replaced by bone. ACL graft tunnels are filled with nonossified material. This study provides a baseline for comparison with other biodegradable interference screws that may encourage bone ingrowth as

  3. Plate-only open door laminoplasty maintains stable spinal canal expansion with high rates of hinge union and no plate failures.

    PubMed

    Rhee, John M; Register, Bradley; Hamasaki, Takahiko; Franklin, Betty

    2011-01-01

    Prospective clinical series. To evaluate the ability of plate-only laminoplasty to achieve stable laminar arch reconstruction and to determine the rate and time course with which bony healing occurs in such constructs. Reconstruction of a stable laminar arch with sufficient room for the decompressed spinal cord is a desired goal when performing cervical laminoplasty for myelopathy. Traditional forms of laminoplasty fixation, such as sutures, bone struts, and ceramic spacers, may be associated with complications including loss of fixation, dislodgement with neurologic compromise, and premature laminoplasty closure. Plates, in contrast, provide more rigid fixation. Plate-only laminoplasty is gaining popularity as a method of laminoplasty fixation, but there is little data on its effectiveness. Fifty-four patients who underwent open door laminoplasty for cervical myelopathy and had available postoperative computed tomography (CT) scans formed the basis of this study. In all cases, a 4-mm round burr was used to create the hinge at the junction of the lateral mass and lamina by completely removing the dorsal cortex and thinning the ventral cortex until a greenstick deformation of the hinge could be produced. Laminoplasty plates were used as the sole method of fixation. No supplemental bone graft struts were used on the plated side, and the hinge side was not bone grafted. Axial CT scans obtained at 3, 6, and 12 months postoperatively were assessed for plate complications and bony healing of the hinge. No plate failures, dislodgements, or premature closures occurred in any of the levels at any time postoperatively. Computed tomography scan review demonstrated that 55% of levels were healed at 3 months, 77% at 6 months, and 93% at 12 months. At each timepoint, C6 and C7 had the highest hinge healing rates. Laminar screw backout was seen in 5/217 (2.3%) of levels, but was not associated with plate dislodgement, laminoplasty closure, or neurologic consequences, and did not

  4. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    PubMed

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  5. [Comparison of clinical effect on locking plate for proximal humeral fracture with or without application of inferomedial screws].

    PubMed

    Guo, Xiu-wu; Fan, Jian; Yuan, Feng

    2016-06-01

    To compare clinical outcomes of locking plate for proximal humeral fracture whether application of inferomedial screws. From January 2012 to July 2013, 46 patients with proximal humeral fracture underwent locking plates were retrospectively analyzed. There were 25 males and 21 females aged from 29 to 80 years old with an average of 55.1 years old. Among them, 25 patients were treated with inferomedial screws (support group), including 13 males and 12 females aged from 38 to 80 years old with an average of (55.8 ± 11.8) years old; 8 cases were part two fracture,10 cases were part three fracture and 7 cases were part four fracture according to Neer classification. Twenty-one patients were treated without inferomedial screws (non-support group), including 12 males and 9 females aged from 29 to 79 years old with an average of (54.2 ± 14.8)years old; 6 cases were part two fracture, 9 cases were part three fracture and 6 cases were part four fracture according to Neer classification. Operative time, fracture healing time and complications were observed and compared, Neer scoring of shoulder joint were used to evaluate clinical effect. All patients were followed up from 12 to 41 months with an average of 15.6 months. Operative time and fracture healing time in support group was (1.6 ± 0.4) h and (3.0 ± 0.6) months, and (1.5 ± 0.4) h and (3.1 ± 0.6) months in non-support group, while there was no statistical difference in operative time and fracture healing time between two groups. There was significant differences in Neer score between support group (89.7± 4.9) and non-support group (83.1 ± 7.1). No complication occurred in support group,while 4 cases occurred complications in non-support group. Locking plate with inferomedial screws for proximal humeral fracture has advantages of stable fixation, less complications, quick recovery of function and satisfied clinical effect.

  6. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    PubMed

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  7. Evaluation of MR issues for the latest standard brands of orthopedic metal implants: plates and screws.

    PubMed

    Zou, Yue-Fen; Chu, Bin; Wang, Chuan-Bing; Hu, Zhi-Yi

    2015-03-01

    The study was performed to evaluate magnetic resonance (MR) issues for the latest standard brands of plates and screws used in orthopedic surgery at a 1.5-T MR system, including the safety and metallic artifacts. The plates and screws (made of titanium alloy and stainless steel materials, according to the latest standard brands) were assessed for displacement in degrees, MRI-related heating and artifacts at a 1.5-T MR system. The displacement in degrees of the plates and screws was evaluated on an angel-measurement instrument at the entrance of the MR scanner. The MRI-related heating was assessed on a swine leg fixed with a plate by using a "worst-case" pulse sequence. A rectangular water phantom was designed to evaluate metallic artifacts of a screw on different sequences (T1/T2-weighted FSE, STIR, T2-FSE fat saturation, GRE, DWI) and then artifacts were evaluated on T2-weighted FSE sequence by modifying the scanning parameters including field of view (FOV), echo train length (ETL) and bandwidth to identify the influence of parameters on metallic artifacts. 15 volunteers with internal vertebral fixation (titanium alloy materials) were scanned with MR using axial and sagittal T2-FSE, sagittal T2-FSE fat suppression and STIR with conventional and optimized parameters, respectively. Then all images were graded by two experienced radiologists having the experience of more than 7 years under double-blind studies that is neither of them knew which was conventional parameter group and optimized parameter group. The average deflection angle of titanium alloy and stainless steel implants were 4.3° and 7.7°, respectively, (less than 45°) which indicated that the magnetically induced force was less than the weight of the object. The deflection angle of the titanium alloy implants was less than the stainless steel one (t=9.69, P<0.001). The average temperature changes of titanium alloy before and after the scan was 0.48°C and stainless steel implants was 0.74

  8. Nerve Damage From Bone Allografts and Xenografts-A Case Series.

    PubMed

    Pogrel, M Anthony

    2017-07-01

    The concept of socket preservation by placing a particulate bone allograft or xenograft into a tooth socket or on the alveolar ridge after tooth removal remains a somewhat controversial topic. The concept is that it will preserve the ridge from resorption and such that subsequent implant insertion will be easier, with fewer complications. However, one particular issue is that these materials, although not directly neurotoxic, appear to be an irritant to the nerves if they come in contact with them. We present a case series demonstrating this complication. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Does maximum torque mean optimal pullout strength of screws?

    PubMed

    Tankard, Sara E; Mears, Simon C; Marsland, Daniel; Langdale, Evan R; Belkoff, Stephen M

    2013-04-01

    To determine the relationship between insertion torque and pullout strength of 3.5-mm-diameter cortical screws in cadaveric humeri with different bone mineral densities (BMDs). Five pairs of human humeri from each of 3 BMD groups (normal, osteopenic, and osteoporotic) were used. Holes were drilled in each humerus, and maximum insertion torque (T(max)) was measured by tightening a screw until stripping occurred. In the remaining holes, screws were tightened to 50%, 70%, or 90% of the T(max). A servohydraulic testing machine pulled each screw out at 1 mm/s while resulting force and axial displacement were recorded at 10 Hz. The authors checked for an effect of insertion torque (percent T(max)) on pullout strength using a general linearized and latent mixed model (Stata10), controlling for cortical thickness and BMD (T-score). Pullout strength for normal and osteoporotic bone was greatest for screws inserted to 50% T(max) and was significantly greater than that at T(max) but not significantly different from that at 70% or 90% T(max). For osteopenic bone, pullout strength was greatest at 70% peak torque, but it was not significantly different from the pullout strength at the 50% or 90% T(max) levels. Tightening screws beyond 50% T(max) does not increase pullout strength of the screw and may place bone at risk for damage that might result in loss of fixation. Even after adjusting for bone thickness and density, there is no clear relationship between pullout strength and screw torque.

  10. Bovine xenograft application for treatment of a metatarsal nonunion fracture in an alpaca (Vicugna pacos).

    PubMed

    Longo, F; Finotti, L; Bellini, L; Zavan, B; Busetto, R; Isola, M

    2016-05-01

    A 15-year-old female huacaya alpaca (Vicugna pacos) was referred because of a non-weight-bearing lameness (4/4) in the left pelvic limb caused by a grade three open metatarsal fracture. The referring veterinarian treated the fracture with conservative management using bandages, but it progressively evolved to a non-union. Clinical examination revealed external wounds on the medial and lateral surfaces of the metatarsus. Radiographs confirmed an open, nonarticular, displaced, diaphyseal fracture of the left metatarsus. Cancellous bone was sourced from bovine proximal and distal femur epiphyses, followed by a thermal shock procedure to achieve decellularisation, to produce a xenograft. Open reduction and internal fixation of the fracture using locking plates was performed. Alignment of the fracture fragments was corrected and the xenograft was placed at the debrided fracture site to stimulate and harness osteogenesis in situ. Clinical and radiographic follow-up was performed up to 40 weeks postoperatively. Clinical evaluations revealed that the alpaca gradually increased weight bearing following bandage removal 10 days after surgery. Serial radiographs showed correct alignment of the left metatarsus, progressive bone modelling and, complete bone union at 12 weeks. Ten months postoperatively the alpaca showed no signs of lameness and resumed normal activity. For management of a metatarsal non-union, a combination of bovine xenograft application and angular stable internal fixation progressed toward an excellent long-term recovery.

  11. Experimental model of bone response to collagenized xenografts of porcine origin (OsteoBiol® mp3): a radiological and histomorphometric study.

    PubMed

    Calvo Guirado, Jose Luis; Ramírez Fernández, Maria Piedad; Negri, Bruno; Delgado Ruiz, Rafael Arcesio; Maté Sánchez de-Val, José Eduardo; Gómez-Moreno, Gerardo

    2013-02-01

    Adequate alveolar ridges are fundamental to successful rehabilitation with implants. There are diverse techniques for reconstructing atrophied ridges, of which bone substitute grafts is one possibility. The aim of this study was to carry out radiological and histomorphometric evaluations of bone response to collagenized porcine bone xenografts over a 4-month period following their insertion in rabbits' tibiae. Twenty New Zealand rabbits were used. Twenty collagenized porcine bone xenografts (Osteobiol® mp3, Tecnoss Dental s.r.l., Torino, Italy), in granulated form of 600 to 1,000 µm, were inserted in the proximal metaphyseal area of the animals' tibiae and 20 control areas were created. Following implantation, the animals were sacrificed in four groups of five, after 1, 2, 3, and 4 months, respectively. Radiological and histomorphometric studies were made. After 4 months, radiological images revealed bone defects with a decrease in graft volume and the complete repair of the osseous defect. No healed or residual bone alterations attributable to the presence of the implants were observed. Histomorphometric analysis at 4 months found mean values for newly formed bone, residual graft material, and non-mineralized connective tissue of 25.4 ± 1.8%, 36.37 ± 3.0%, and 38.22 ± 2.5%, respectively. There were no statistical differences in the length of cortical formation with collagenized porcine xenograft (98.9 ± 1.1%) compared with the control samples (99.1 ± 0.7%) at the end of the study period. The biomaterial used proved to be biocompatible, bioabsorbable, and osteoconductive and as such, a possible bone substitute that did not interfere with the bone's normal reparative processes. © 2011 Wiley Periodicals, Inc.

  12. Time-elapsed screw insertion with microCT imaging.

    PubMed

    Ryan, M K; Mohtar, A A; Cleek, T M; Reynolds, K J

    2016-01-25

    Time-elapsed analysis of bone is an innovative technique that uses sequential image data to analyze bone mechanics under a given loading regime. This paper presents the development of a novel device capable of performing step-wise screw insertion into excised bone specimens, within the microCT environment, whilst simultaneously recording insertion torque, compression under the screw head and rotation angle. The system is computer controlled and screw insertion is performed in incremental steps of insertion torque. A series of screw insertion tests to failure were performed (n=21) to establish a relationship between the torque at head contact and stripping torque (R(2)=0.89). The test-device was then used to perform step-wise screw insertion, stopping at intervals of 20%, 40%, 60% and 80% between screw head contact and screw stripping. Image data-sets were acquired at each of these time-points as well as at head contact and post-failure. Examination of the image data revealed the trabecular deformation as a result of increased insertion torque was restricted to within 1mm of the outer diameter of the screw thread. Minimal deformation occurred prior to the step between the 80% time-point and post-failure. The device presented has allowed, for the first time, visualization of the micro-mechanical response in the peri-implant bone with increased tightening torque. Further testing on more samples is expected to increase our understanding of the effects of increased tightening torque at the micro-structural level, and the failure mechanisms of trabeculae. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Feasibility of detecting orthopaedic screw overtightening using acoustic emission.

    PubMed

    Pullin, Rhys; Wright, Bryan J; Kapur, Richard; McCrory, John P; Pearson, Matthew; Evans, Sam L; Crivelli, Davide

    2017-03-01

    A preliminary study of acoustic emission during orthopaedic screw fixation was performed using polyurethane foam as the bone-simulating material. Three sets of screws, a dynamic hip screw, a small fragment screw and a large fragment screw, were investigated, monitoring acoustic-emission activity during the screw tightening. In some specimens, screws were deliberately overtightened in order to investigate the feasibility of detecting the stripping torque in advance. One set of data was supported by load cell measurements to directly measure the axial load through the screw. Data showed that acoustic emission can give good indications of impending screw stripping; such indications are not available to the surgeon at the current state of the art using traditional torque measuring devices, and current practice relies on the surgeon's experience alone. The results suggest that acoustic emission may have the potential to prevent screw overtightening and bone tissue damage, eliminating one of the commonest sources of human error in such scenarios.

  14. The effect of screw tunnels on the biomechanical stability of vertebral body after pedicle screws removal: a finite element analysis.

    PubMed

    Liu, Jia-Ming; Zhang, Yu; Zhou, Yang; Chen, Xuan-Yin; Huang, Shan-Hu; Hua, Zi-Kai; Liu, Zhi-Li

    2017-06-01

    Posterior reduction and pedicle screw fixation is a widely used procedure for thoracic and lumbar vertebrae fractures. Usually, the pedicle screws would be removed after the fracture healing and screw tunnels would be left. The aim of this study is to evaluate the effect of screw tunnels on the biomechanical stability of the lumbar vertebral body after pedicle screws removal by finite element analysis (FEA). First, the CT values of the screw tunnels wall in the fractured vertebral bodies were measured in patients whose pedicle screws were removed, and they were then compared with the values of vertebral cortical bone. Second, an adult patient was included and the CT images of the lumbar spine were harvested. Three dimensional finite element models of the L1 vertebra with unilateral or bilateral screw tunnels were created based on the CT images. Different compressive loads were vertically acted on the models. The maximum loads which the models sustained and the distribution of the force in the different parts of the models were recorded and compared with each other. The CT values of the tunnels wall and vertebral cortical bone were 387.126±62.342 and 399.204±53.612, which were not statistically different (P=0.149). The models of three dimensional tetrahedral mesh finite element of normal lumbar 1 vertebra were established with good geometric similarity and realistic appearance. After given the compressive loads, the cortical bone was the first one to reach its ultimate stress. The maximum loads which the bilateral screw tunnels model, unilateral screw tunnel model, and normal vertebral model can sustain were 3.97 Mpa, 3.83 Mpa, and 3.78 Mpa, respectively. For the diameter of the screw tunnels, the model with a diameter of 6.5 mm could sustain the largest load. In addition, the stress distributing on the outside of the cortical bone gradually decreased as the thickness of the tunnel wall increased. Based on the FEA, pedicle screw tunnels would not decrease the

  15. Technique for fixing a temporalis muscle using a titanium plate to the implanted hydroxyapatite ceramics for bone defects.

    PubMed

    Ono, I; Tateshita, T; Sasaki, T; Matsumoto, M; Kodama, N

    2001-05-01

    We devised a technique to fix the temporalis muscle to the transplanted hydroxyapatite implant by using a titanium plate, which is fixed to the hydroxyapatite ceramic implant by screws and achieves good clinical results. The size, shape, and curvature of the hydroxyapatite ceramic implants were determined according to full-scale models fabricated using the laser lithographic modeling method from computed tomography data. A titanium plate was then fixed with screws on the implant before implantation, and then the temporalis muscle was refixed to the holes at both ends of the plate. The application of this technique reduced the hospitalization time and achieved good results esthetically.

  16. Tympanic plate fractures in temporal bone trauma: prevalence and associated injuries.

    PubMed

    Wood, C P; Hunt, C H; Bergen, D C; Carlson, M L; Diehn, F E; Schwartz, K M; McKenzie, G A; Morreale, R F; Lane, J I

    2014-01-01

    The prevalence of tympanic plate fractures, which are associated with an increased risk of external auditory canal stenosis following temporal bone trauma, is unknown. A review of posttraumatic high-resolution CT temporal bone examinations was performed to determine the prevalence of tympanic plate fractures and to identify any associated temporal bone injuries. A retrospective review was performed to evaluate patients with head trauma who underwent emergent high-resolution CT examinations of the temporal bone from July 2006 to March 2012. Fractures were identified and assessed for orientation; involvement of the tympanic plate, scutum, bony labyrinth, facial nerve canal, and temporomandibular joint; and ossicular chain disruption. Thirty-nine patients (41.3 ± 17.2 years of age) had a total of 46 temporal bone fractures (7 bilateral). Tympanic plate fractures were identified in 27 (58.7%) of these 46 fractures. Ossicular disruption occurred in 17 (37.0%). Fractures involving the scutum occurred in 25 (54.4%). None of the 46 fractured temporal bones had a mandibular condyle dislocation or fracture. Of the 27 cases of tympanic plate fractures, 14 (51.8%) had ossicular disruption (P = .016) and 18 (66.6%) had a fracture of the scutum (P = .044). Temporomandibular joint gas was seen in 15 (33%) but was not statistically associated with tympanic plate fracture (P = .21). Tympanic plate fractures are commonly seen on high-resolution CT performed for evaluation of temporal bone trauma. It is important to recognize these fractures to avoid the preventable complication of external auditory canal stenosis and the potential for conductive hearing loss due to a fracture involving the scutum or ossicular chain.

  17. Ability of modern distal tibia plates to stabilize comminuted pilon fracture fragments: Is dual plate fixation necessary?

    PubMed

    Penny, Phillip; Swords, Michael; Heisler, Jason; Cien, Adam; Sands, Andrew; Cole, Peter

    2016-08-01

    The purpose of this study was to examine the screw trajectory of ten commercially available distal tibia plates and compare them to common fracture patterns seen in OTA C type pilon fractures to determine their ability to stabilize the three most common fracture fragments while buttressing anterolateral zones of comminution. We hypothesized that a single plate for the distal tibia would fail to adequately stabilize all three main fracture fragments and zones of comminution in complex pilon fractures. Ten synthetic distal tibia sawbones models were used in conjunction with ten different locking distal tibia plate designs from three manufacturers (Depuy Synthes, J&J Co, Paoli, PA; Smith & Nephew, Memphis, TN; and Stryker, Mawa, NJ). Both medial and anterolateral plates from each company were utilized and separately applied to an individual sawbone model. Three implants allowing variable angle screw placement were used. The location of the locking screws and buttress effect 1cm above the articular surface was noted for each implant using axial computed tomography (CT). The images were then compared to a recently published "pilon fracture map" using an overlay technique to establish the relationship between screw location and known common fracture lines and areas of comminution. Each of the three main fragments was considered "captured" by a screw if it was purchased by at least two screws thereby controlling rotational forces on each fragment. Three of four anterolateral plates lacked stable fixation in the medial fragment. Of the 4 anterolateral plates used, only the variable angle anterolateral plate by Depuy Synthes captured the medial fragment with two screws. All four anterolateral plates buttressed the area of highest comminution and had an average of 1.25 screws in the medial fragment and an average of 3 screws in the posterolateral fragment. All five direct medial plates had variable fixation within anterolateral and posterolateral fragments with an average of

  18. Fractographic analysis of 2.0-mm plates with a screw locking system in simulated fractures of the mandibular body.

    PubMed

    de Medeiros, Raquel Correia; Lauria de Moura, Andrezza; Rodrigues, Danillo Costa; Menezes Mendes, Marcelo Breno; Sawazaki, Renato; Fernandes Moreira, Roger William

    2014-06-01

    The purpose of the present study was to analyze the fractured plates from 2 brands of 2.0-mm locking fixation systems submitted to axial linear load testing. Four aluminum hemimandibles with linear sectioning to simulate a mandibular body fracture were used as a substrate and fixed with 2 fixation techniques from 2 national brands: Tóride and Traumec. The techniques were as follows: one 4-hole plate, with four 6-mm screws in the tension zone, and one 4-hole plate, with four 10-mm screws in the compression zone; and one 4-hole plate, with four 6-mm holes in the neutral zone. The hemimandibles were submitted to vertical linear load tests using an Instron 4411 mechanical test machine. The system was submitted to the test until complete failure had occurred. Next, a topographic analysis of the surface of the plates was performed using a stereomicroscope and an electronic scanning microscope. The samples were evaluated using different magnifications, and images were obtained. The surface of the fracture analyzed in scanning electron microscopy demonstrated a ductile-type fracture, usually found in the traction test bodies of ductile materials, such as titanium. No evidence of failure was observed in any fracture surface from a change in the structure or composition of the material. The plates were fractured by a ductile rupture mechanism, as expected, suggesting that the manufacturing of the national brand name plates used in the present study has been under adequate quality control, with no structural changes produced by the manufacturing process that could compromise their function. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Design of a surgical instrument for removing bone to provide screw access to a spinal fusion cage.

    PubMed

    Jabbary Aslani, F; Hukins, D W L; Shepherd, D E T; Parry, J J; Fennell, A J; Lambell, S

    2012-01-01

    A surgical instrument to aid implantation of a range of lumbar spinal fusion cages has been developed. Once the cage is in position, the entrance to screw holes is partially blocked by the edge of the vertebral body. In order to insert fixation screws to secure the cage between the vertebrae, some part of the blocking edge has to be removed. Rongeurs are currently being used, but they can be time consuming and have the disadvantage that they may remove more bone than is necessary and may cause damage to the fusion cage if not used with care. In addition, access around some of the screw holes may be difficult. The aim of this instrument was to overcome these shortcomings. This paper describes the design of a surgical instrument for cutting edges from vertebral bodies. The development and evaluation of concept designs are presented and discussed. Potential risks were considered and modifications were performed on the selected concept. Functional prototypes were manufactured and tested on sheep lumbar vertebrae. The results showed that the newly designed cutting instrument functions as required and removes the required amount of bone from the vertebral body edge.

  20. The mechanical and morphological properties of bone beneath internal fixation plates of differing rigidity.

    PubMed

    Claes, L

    1989-01-01

    The internal fixation of diaphyseal fractures by bone plates is a well recognized treatment. The normal physiological stress of bone is reduced by plates that cause a negative balance of bone-remodeling processes. Many investigators have shown that the degree of stress protection is dependent on the rigidity of the plates. It was the aim of this study to quantify mechanical and morphological changes at different locations in a plated diaphyseal bone as a function of differing plate rigidity. Two types of plates with the same size but different materials were used. The stainless steel plates had a modulus of elasticity and bending stiffness 3.2 times higher than the carbon fiber reinforced carbon plates. Both types of plates were applied to the intact right and left femora of six foxhounds for 6 months. The stiffer stainless steel plates led to a significantly higher bone loss and correspondingly greater loss of mechanical properties. These effects were greatest directly beneath the plate and less with increasing distance from the plate.

  1. Comparison of circummandibular wiring with resorbable bone plates in pediatric mandibular fractures.

    PubMed

    Saikrishna, D; Gupta, Nimish

    2010-06-01

    Pediatric patients present a unique challenge to maxillofacial surgeons in terms of their treatment planning as well as in their functional and nutritional needs which are different from that of adult patients. Early literature has advocated conservative closed management of pediatric fractures to prevent complications. However recent advances in maxillofacial surgery has enabled us to use biodegradable plates and screws, which overcomes the limitations of metallic plates. We present a comparison of two cases of parasymphysis fracture treated with circum-mandibular wiring and biodegradable plate fixation their outcome in terms of fracture healing and functional stability.

  2. Fixation of osteoporotic fractures in the upper limb with a locking compression plate.

    PubMed

    Neuhaus, V; King, J D; Jupiter, J B

    2012-01-01

    Locking Compression Plate (LCP) has the advantageous feature that screws can be locked in the plate leaving an angular stable construct. There is no need to have contact between the plate and the bone to achieve stability resulting from friction of the plate-bone-construct. Therefore the plate does not need to be contoured exactly to the bone and the healing bone's periosteal blood supply is not affected. The LCP is used as a bridging plate to gain relative stability in multi-fragmentary, diaphyseal or metaphyseal fractures. Depending on the fracture, the combination hole can also allow the LCP to achieve absolute stability similar to conventional fixation techniques. Osteoporotic fractures have significant impact on morbidity and mortality. Proximal humeral and distal radius fractures are typical examples. These osteoporotic and often comminuted fractures are ideal settings/indications for LCP utilization in the upper extremity. However, the data quality is due to mostly small study populations not so powerful. Unquestionably there has been a clear and fashionable trend to choose operative treatment for these fractures, because the angular stability allows stable fixation and early functional mobilization.

  3. [Biomaterials in bone repair].

    PubMed

    Puska, Mervi; Aho, Allan J; Vallittu, Pekka K

    2013-01-01

    In orthopedics, traumatology, and craniofacial surgery, biomaterials should meet the clinical demands of bone that include shape, size and anatomical location of the defect, as well as the physiological load-bearing stresses. Biomaterials are metals, ceramics, plastics or materials of biological origin. In the treatment of large defects, metallic endoprostheses or bone grafts are employed, whereas ceramics in the case of small defects. Plastics are employed on the artificial joint surfaces, in the treatment of vertebral compression fractures, and as biodegradable screws and plates. Porosity, bioactivity, and identical biomechanics to bone are fundamental for achieving a durable, well-bonded, interface between biomaterial and bone. In the case of severe bone treatments, biomaterials should also imply an option to add biologically active substances.

  4. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates.

    PubMed

    Matsuura, Yusuke; Rokkaku, Tomoyuki; Suzuki, Takane; Thoreson, Andrew Ryan; An, Kai-Nan; Kuniyoshi, Kazuki

    2017-08-01

    Forearm diaphysis fractures are usually managed by open reduction internal fixation. Recently, locking plates have been used for treatment. In the long-term period after surgery, some patients present with bone atrophy adjacent to the plate. However, a comparison of locking and conventional plates as a cause of atrophy has not been reported. The aim of this study was to investigate long-term bone atrophy associated with use of locking and conventional plates for forearm fracture treatment. In this study we included 15 patients with forearm fracture managed by either locking or conventional plates and with more than 5 years of follow-up. Computed tomographic imaging of both forearms was performed to assess bone thickness and local bone mineral density and to predict bone strength without plate reinforcement based on finite element analysis. Mean patient age at surgery was 48.0 years. Eight patients underwent reduction with fixed locking plates and were followed up for a mean of 79.5 months; the remaining 7 patients were treated with conventional plates and were followed up for a mean of 105.0 months. Compared with the conventional plate group, the locking plate group had the same fractured limb-contralateral limb ratio of cortex bone thickness, but had significantly lower ratios of mineral density adjacent to the plate and adjusted bone strength. This study demonstrated bone atrophy after locking plate fixation for forearm fractures. Treatment plans for forearm fracture should take into consideration the impact of bone atrophy long after plate fixation. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. On optimization of a composite bone plate using the selective stress shielding approach.

    PubMed

    Samiezadeh, Saeid; Tavakkoli Avval, Pouria; Fawaz, Zouheir; Bougherara, Habiba

    2015-02-01

    Bone fracture plates are used to stabilize fractures while allowing for adequate compressive force on the fracture ends. Yet the high stiffness of conventional bone plates significantly reduces compression at the fracture site, and can lead to subsequent bone loss upon healing. Fibre-reinforced composite bone plates have been introduced to address this drawback. However, no studies have optimized their configurations to fulfill the requirements of proper healing. In the present study, classical laminate theory and the finite element method were employed for optimization of a composite bone plate. A hybrid composite made of carbon fibre/epoxy with a flax/epoxy core, which was introduced previously, was optimized by varying the laminate stacking sequence and the contribution of each material, in order to minimize the axial stiffness and maximize the torsional stiffness for a given range of bending stiffness. The initial 14×4(14) possible configurations were reduced to 13 after applying various design criteria. A comprehensive finite element model, validated against a previous experimental study, was used to evaluate the mechanical performance of each composite configuration in terms of its fracture stability, load sharing, and strength in transverse and oblique Vancouver B1 fracture configurations at immediately post-operative, post-operative, and healed bone stages. It was found that a carbon fibre/epoxy plate with an axial stiffness of 4.6 MN, and bending and torsional stiffness of 13 and 14 N·m(2), respectively, showed an overall superiority compared with other laminate configurations. It increased the compressive force at the fracture site up to 14% when compared to a conventional metallic plate, and maintained fracture stability by ensuring the fracture fragments' relative motions were comparable to those found during metallic plate fixation. The healed stage results revealed that implantation of the titanium plate caused a 40.3% reduction in bone stiffness

  6. Three-Point Gear/Lead Screw Positioning

    NASA Technical Reports Server (NTRS)

    Calco, Frank S.

    1993-01-01

    Triple-ganged-lead-screw positioning mechanism drives movable plate toward or away from fixed plate and keeps plates parallel to each other. Designed for use in tuning microwave resonant cavity. Other potential applications include adjustable bed plates and cantilever tail stocks in machine tools, adjustable platforms for optical equipment, and lifting platforms.

  7. Comparison of the Lag Screw Placements for the Treatment of Stable and Unstable Intertrochanteric Femoral Fractures regarding Trabecular Bone Failure.

    PubMed

    Celik, Talip; Mutlu, Ibrahim; Ozkan, Arif; Kisioglu, Yasin

    2016-01-01

    Background. In this study, the cut-out risk of Dynamic Hip Screw (DHS) was investigated in nine different positions of the lag screw for two fracture types by using Finite Element Analysis (FEA). Methods. Two types of fractures (31-A1.1 and A2.1 in AO classification) were generated in the femur model obtained from Computerized Tomography images. The DHS model was placed into the fractured femur model in nine different positions. Tip-Apex Distances were measured using SolidWorks. In FEA, the force applied to the femoral head was determined according to the maximum value being observed during walking. Results. The highest volume percentage exceeding the yield strength of trabecular bone was obtained in posterior-inferior region in both fracture types. The best placement region for the lag screw was found in the middle of both fracture types. There are compatible results between Tip-Apex Distances and the cut-out risk except for posterior-superior and superior region of 31-A2.1 fracture type. Conclusion. The position of the lag screw affects the risk of cut-out significantly. Also, Tip-Apex Distance is a good predictor of the cut-out risk. All in all, we can supposedly say that the density distribution of the trabecular bone is a more efficient factor compared to the positions of lag screw in the cut-out risk.

  8. Comparison of the Lag Screw Placements for the Treatment of Stable and Unstable Intertrochanteric Femoral Fractures regarding Trabecular Bone Failure

    PubMed Central

    Mutlu, Ibrahim; Ozkan, Arif; Kisioglu, Yasin

    2016-01-01

    Background. In this study, the cut-out risk of Dynamic Hip Screw (DHS) was investigated in nine different positions of the lag screw for two fracture types by using Finite Element Analysis (FEA). Methods. Two types of fractures (31-A1.1 and A2.1 in AO classification) were generated in the femur model obtained from Computerized Tomography images. The DHS model was placed into the fractured femur model in nine different positions. Tip-Apex Distances were measured using SolidWorks. In FEA, the force applied to the femoral head was determined according to the maximum value being observed during walking. Results. The highest volume percentage exceeding the yield strength of trabecular bone was obtained in posterior-inferior region in both fracture types. The best placement region for the lag screw was found in the middle of both fracture types. There are compatible results between Tip-Apex Distances and the cut-out risk except for posterior-superior and superior region of 31-A2.1 fracture type. Conclusion. The position of the lag screw affects the risk of cut-out significantly. Also, Tip-Apex Distance is a good predictor of the cut-out risk. All in all, we can supposedly say that the density distribution of the trabecular bone is a more efficient factor compared to the positions of lag screw in the cut-out risk. PMID:27995133

  9. Carbon nanotubes with high bone-tissue compatibility and bone-formation acceleration effects.

    PubMed

    Usui, Yuki; Aoki, Kaoru; Narita, Nobuyo; Murakami, Narumichi; Nakamura, Isao; Nakamura, Koichi; Ishigaki, Norio; Yamazaki, Hiroshi; Horiuchi, Hiroshi; Kato, Hiroyuki; Taruta, Seiichi; Kim, Yoong Ahm; Endo, Morinobu; Saito, Naoto

    2008-02-01

    Carbon nanotubes (CNTs) have been used in various fields as composites with other substances or alone to develop highly functional materials. CNTs hold great interest with respect to biomaterials, particularly those to be positioned in contact with bone such as prostheses for arthroplasty, plates or screws for fracture fixation, drug delivery systems, and scaffolding for bone regeneration. Accordingly, bone-tissue compatibility of CNTs and CNT influence on bone formation are important issues, but the effects of CNTs on bone have not been delineated. Here, it is found that multi-walled CNTs adjoining bone induce little local inflammatory reaction, show high bone-tissue compatibility, permit bone repair, become integrated into new bone, and accelerate bone formation stimulated by recombinant human bone morphogenetic protein-2 (rhBMP-2). This study provides an initial investigational basis for CNTs in biomaterials that are used adjacent to bone, including uses to promote bone regeneration. These findings should encourage development of clinical treatment modalities involving CNTs.

  10. Unstable metacarpal and phalangeal fractures: treatment by internal fixation using AO mini-fragment plates and screws.

    PubMed

    Mumtaz, Mohammad Umar; Farooq, Muneer Ahmad; Rasool, Altaf Ahmad; Kawoosa, Altaf Ahmad; Badoo, Abdul Rashid; Dhar, Shabir Ahmad

    2010-07-01

    Accurate open reduction and internal fixation for metacarpal and phalangeal fractures of the hand is required in less than 5% of the patients; otherwise, closed treatment techniques offer satisfactory results in most of these cases as these fractures are stable either before or after closed reduction. AO mini-fragment screws and plates, when used in properly selected cases, can provide rigid fixation, allowing early mobilization of joints and hence good functional results while avoiding problems associated with protruding K-wires and immobilization. The advantages of such internal fixation urged us to undertake such a study in our state where such hand injuries are commonly seen. Forty patients with 42 unstable metacarpal and phalangeal fractures were treated with open reduction and internal fixation using AO mini-fragment screws and plates over a period of three years in a prospective manner. The overall results were good in 78.5% of cases, fair in 19% of cases and poor in 2.5% of cases, as judged according to the criteria of the American Society for Surgery of the Hand. This technique is a reasonable option for treating unstable metacarpal and phalangeal fractures as it provides a highly rigid fixation, which is sufficient to allow early mobilization of the adjacent joints, thus helping to achieve good functional results.

  11. Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting On Disorders of the Spine and Peripheral Nerves, March 2005.

    PubMed

    Wang, Jeremy C; Haid, Regis W; Miller, Jay S; Robinson, James C

    2006-02-01

    The authors present the early clinical results obtained in patients who underwent SPIRE spinous process plate fixation following anterior lumbar interbody fusion (ALIF). Between May 2003 and January 2005, 32 patients underwent titanium cage and bone morphogenetic protein-augmented ALIF and subsequent SPIRE (21 cases) or bilateral pedicle screw (BPS; 11 cases) fixation. Pedicle screws were implanted using either the open approach (three cases) or using a tubular retractor (eight cases). Patients' charts were reviewed for operative time, estimated blood loss (EBL), hospital length of stay (LOS), and evidence of pseudarthrosis or hardware failure. In SPIRE plate-treated patients, the median EBL (75 ml) was lower than in BPS-treated patients (open BPS [150 ml]; tubular BPS [125 ml]). The median operative time in SPIRE plate-treated patients was also shorter (164 minutes compared with 239 and 250 minutes in the open and tubular BPS, respectively). The median LOS was 3 days for both the SPIRE and tubular BPS groups, but 4 days in the open BPS group. There were no instances of major surgery-induced complication, pseudarthrosis, or hardware failure during mean follow-up periods of 5.5, 7.2, and 4.9 months in the SPIRE, open PS, and tubular BPS groups, respectively. The SPIRE plate is easy to implant and is associated with minimal operative risk. Compared with BPS/rod constructs, SPIRE plate fixation leads to less EBL and shorter operative time, without an increase in the rate of pseudarthrosis. Hospital LOS was also shorter in SPIRE plate-treated patients, which is consistent with the goals of minimal access spinal technologies.

  12. Temperature evaluation during PMMA screw augmentation in osteoporotic bone--an in vitro study about the risk of thermal necrosis in human femoral heads.

    PubMed

    Boner, Vanessa; Kuhn, Philipp; Mendel, Thomas; Gisep, Armando

    2009-08-01

    The use of polymethylmethacrylate (PMMA) bone cement to augment hip screws reduces cut-out risk but is associated with an exothermic reaction. This in vitro investigation evaluated the risk of thermal necrosis when augmenting the implant purchase with PMMA. A pilot study analyzed the effects of different PMMA layer thicknesses on temperatures around an implant. The main study used either 3.0 or 6.0 cc PMMA for hip screw augmentation in human femoral heads. The risk of thermal necrosis was estimated according to critical values reported in literature. Highest temperatures were measured inside the PMMA with a significant drop of average maximum temperatures from the center of the PMMA to the PMMA/bone interface. Risk of thermal necrosis exists with PMMA layer thicknesses greater than 5.0 mm. In the main study, we found no risk of thermal necrosis at the PMMA/bone interface or in the surrounding bone, neither with 3.0 nor 6.0 cc PMMA. The results of the two studies were consistent regarding average peak temperatures related to associated cement layer thicknesses. The results of this in vitro study reduce objections concerning the risk of thermal necrosis when augmenting cancellous bone around hip screws with up to 6.0 cc PMMA.

  13. [Conventional plate osteosynthesis].

    PubMed

    Klaue, K

    2010-02-01

    Consolidation of bone is an essential clinical problem when treating fractures, fixing osteotomies and fusing joints. In most cases, the means of fixation are plates and screws. The goal is functional postoperative therapy by moving the adjacent joints and thus avoiding the deleterious disadvantages of long-lasting articular immobilization. Pre-operative planning, surgical approach, a good understanding of the precise mechanics of the structure and the biological answer for the various tissues are prerequisites of successful osteosynthesis. The choice of implants and the application of their versatility, as well as their adaptation to individual cases are the key to good results.

  14. Fixation of zygomatic and mandibular fractures with biodegradable plates.

    PubMed

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    In this prospective study, 13 randomly selected patients underwent treatment for zygomatic-complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Descriptives, Frequencies, and Chi-square test were used. In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome.

  15. Fixation of zygomatic and mandibular fractures with biodegradable plates

    PubMed Central

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    Context: In this prospective study, 13 randomly selected patients underwent treatment for zygomatic–complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. Aims: To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. Materials and Methods: In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Statistical Analysis Used: Descriptives, Frequencies, and Chi-square test were used. Results: In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Conclusions: Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome. PMID:23662255

  16. Perfusion pressure of a new cannulating fenestrated pedicle screw during cement augmentation.

    PubMed

    Wang, Zhirong; Zhang, Wen; Xu, Hao; Lu, Aiqing; Yang, Huilin; Luo, Zong-Ping

    2018-06-18

    Cannulating fenestrated pedicle screws are effective for fixating osteoporotic vertebrae. However, a major limitation is the excessive pressure required to inject a sufficient amount of cement into the vertebral body through the narrow hole of a pedicle screw. We have recently proposed a new cannulating fenestrated pedicle screw with a large hole diameter and a matched inner pin for screw-strength maintenance. Our purpose was to determine whether the new screw can significantly reduce bone-cement perfusion pressure during cement augmentation, METHODS: Two different methods were used to examine perfusion pressure. Hagen-Poisseuille's flow model in a tube was used to calculate pressure drop in the bone-cement channel. Experimentally, both Newtonian silicone oil and bone-cement (polymethyl methacrylate) were tested using a cement pusher through the cannulating screw at a constant rate of 2 ml/min. The internal hollow portion of the screw was the bottleneck of the perfusion, and the new design significantly reduced the perfusion pressure. Specifically, perfusion pressure dropped by 59% (P < 0.05) when diameter size was doubled. The new design effectively improved the application of bone-cement augmentation with the ease of bone-cement perfusion, thereby enhancing operational safety. Copyright © 2018. Published by Elsevier Ltd.

  17. A tissue-engineered humanized xenograft model of human breast cancer metastasis to bone

    PubMed Central

    Thibaudeau, Laure; Taubenberger, Anna V.; Holzapfel, Boris M.; Quent, Verena M.; Fuehrmann, Tobias; Hesami, Parisa; Brown, Toby D.; Dalton, Paul D.; Power, Carl A.; Hollier, Brett G.; Hutmacher, Dietmar W.

    2014-01-01

    ABSTRACT The skeleton is a preferred homing site for breast cancer metastasis. To date, treatment options for patients with bone metastases are mostly palliative and the disease is still incurable. Indeed, key mechanisms involved in breast cancer osteotropism are still only partially understood due to the lack of suitable animal models to mimic metastasis of human tumor cells to a human bone microenvironment. In the presented study, we investigate the use of a human tissue-engineered bone construct to develop a humanized xenograft model of breast cancer-induced bone metastasis in a murine host. Primary human osteoblastic cell-seeded melt electrospun scaffolds in combination with recombinant human bone morphogenetic protein 7 were implanted subcutaneously in non-obese diabetic/severe combined immunodeficient mice. The tissue-engineered constructs led to the formation of a morphologically intact ‘organ’ bone incorporating a high amount of mineralized tissue, live osteocytes and bone marrow spaces. The newly formed bone was largely humanized, as indicated by the incorporation of human bone cells and human-derived matrix proteins. After intracardiac injection, the dissemination of luciferase-expressing human breast cancer cell lines to the humanized bone ossicles was detected by bioluminescent imaging. Histological analysis revealed the presence of metastases with clear osteolysis in the newly formed bone. Thus, human tissue-engineered bone constructs can be applied efficiently as a target tissue for human breast cancer cells injected into the blood circulation and replicate the osteolytic phenotype associated with breast cancer-induced bone lesions. In conclusion, we have developed an appropriate model for investigation of species-specific mechanisms of human breast cancer-related bone metastasis in vivo. PMID:24713276

  18. Internal bone transport using a cannulated screw as a mounting device in the treatment of a post-infective ulnar defect.

    PubMed

    Tsitskaris, Konstantinos; Havard, Heledd; Bijlsma, Paulien; Hill, Robert A

    2016-04-01

    Bone transport techniques can be used to address the segmental bone loss occurring after debridement for infection. Secure fixation of the bone transport construct to the bone transport segment can be challenging, particularly if the bone is small and osteopenic. We report a case of a segmental ulnar bone defect in a young child treated with internal bone transport using a cannulated screw as the mounting device. We found this technique particularly useful in the treatment of bone loss secondary to infection, where previous treatment and prolonged immobilisation had led to osteopenia. This technique has not been previously reported.

  19. Growth plate closure: Apex view on bone scan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giles, P.H.; Trochei, M.; Yeates, K.

    1984-01-01

    Angular deformities of the extremities in children following premature closure of the growth plate are well known. The deformities depend on the position of an osseus bridge which forms between the epiphysis and metaphysis. Several surgical procedures including resection of the osseus bridge have been described, however, delineation of the site of fusion is difficult to define. The commonest site of growth plate arrest is the distal femoral or proximal tibial growth plate. A new technique using the bone scan has been developed which accurately defines the area and position of these osseus bridges. Two hours after injection of technetiummore » 99m methylene diphosphonate apex views of the affected distal femoral growth plate were performed. The knee was flexed into its smallest angle. Using a pinhole collimator the gamma camera was angled to face the affected growth plate end on. The image was collected onto computer and analysed by: (I) regions of interest over segments of the growth plate to calculate the relative area of total growth plate affected: (II) generating histograms: (III) thresholding or performing isocontours to accentuate abnormal areas. The growth plate is normally uniformly increased when compared to the normal shaft of the bone. Fusion across the plate appears as an area of diminished uptake. The apex view gives a unique functional map of the growth plate such that abnormal areas are displayed, and the site, size and position of osseus fusion obtained. The technique has the potential for determining the metabolic activity of the growth plate before and after surgery. Serial studies will allow assessment of regneration of the plate and reformation of new osseus bridges.« less

  20. Biodegradable screw versus a press-fit bone plug fixation for hamstring anterior cruciate ligament reconstruction: a prospective randomized study.

    PubMed

    Jagodzinski, Michael; Geiges, Bjoern; von Falck, Christian; Knobloch, Karsten; Haasper, Carl; Brand, Juergen; Hankemeier, Stefan; Krettek, Christian; Meller, Rupert

    2010-03-01

    Press-fit fixation of a tendon graft has been advocated to achieve tendon-to-bone healing. Fixation of hamstring tendon grafts with a porous bone scaffold limits bone tunnel enlargement compared with a biodegradable interference screw fixation. Randomized controlled trial; Level of evidence, 1. Methods Between 2005 and 2006, 20 patients (17 men, 3 women) with a primary reconstruction of the anterior cruciate ligament (ACL) were enrolled in this study. Patients were randomized to obtain graft fixation in the tibial tunnel either by means of an interference screw (I) or a press-fit fixation with a porous bone cylinder (P). At 3 months after surgery, a computed tomography (CT) scan of the knee was performed, and tunnel enlargement was analyzed in the coronal and sagittal planes for the proximal, middle, and distal thirds of the tunnel. After 6 months and 1 and 2 years, radiographs of the knee in the sagittal and coronal plane were analyzed for bone tunnel widening. The International Knee Documentation Committee (IKDC), Tegner, and Lysholm scores of both groups were compared after 1 and 2 years. The bone tunnel enlargement determined by CT was 106.9% + or - 10.9% for group P and 121.9% + or - 9.0% for group I (P < .02) in the anteroposterior (AP) plane and 102.8% + or - 15.2% versus 121.5% + or - 10.1% in the coronal plane (P <.01). The IKDC, Tegner, and Lysholm scores improved in both groups from preoperatively to postoperatively without significant differences between the 2 groups. There was a trend to higher knee stability in group P after 3 months (0.6 + or - 1.4 mm vs 1.8 + or - 1.5 mm; P = .08). Both interference screw and a press-fit fixation lead to a high number of good or very good outcomes after ACL reconstruction. Tibial press-fit fixation decreases the amount of proximal bone tunnel enlargement.

  1. 8-Nitro-cGMP promotes bone growth through expansion of growth plate cartilage.

    PubMed

    Hoshino, Marie; Kaneko, Kotaro; Miyamoto, Yoichi; Yoshimura, Kentaro; Suzuki, Dai; Akaike, Takaaki; Sawa, Tomohiro; Ida, Tomoaki; Fujii, Shigemoto; Ihara, Hideshi; Tanaka, Junichi; Tsukuura, Risa; Chikazu, Daichi; Mishima, Kenji; Baba, Kazuyoshi; Kamijo, Ryutaro

    2017-09-01

    In endochondral ossification, growth of bones occurs at their growth plate cartilage. While it is known that nitric oxide (NO) synthases are required for proliferation of chondrocytes in growth plate cartilage and growth of bones, the precise mechanism by which NO facilitates these process has not been clarified yet. C-type natriuretic peptide (CNP) also positively regulate elongation of bones through expansion of the growth plate cartilage. Both NO and CNP are known to use cGMP as the second messenger. Recently, 8-nitro-cGMP was identified as a signaling molecule produced in the presence of NO in various types of cells. Here, we found that 8-nitro-cGMP is produced in proliferating chondrocytes in the growth plates, which was enhanced by CNP, in bones cultured ex vivo. In addition, 8-nitro-cGMP promoted bone growth with expansion of the proliferating zone as well as increase in the number of proliferating cells in the growth plates. 8-Nitro-cGMP also promoted the proliferation of chondrocytes in vitro. On the other hand, 8-bromo-cGMP enhanced the growth of bones with expansion of hypertrophic zone of the growth plates without affecting either the width of proliferating zone or proliferation of chondrocytes. These results indicate that 8-nitro-cGMP formed in growth plate cartilage accelerates chondrocyte proliferation and bone growth as a downstream molecule of NO. Copyright © 2017. Published by Elsevier Inc.

  2. Reinforcement of osteosynthesis screws with brushite cement.

    PubMed

    Van Landuyt, P; Peter, B; Beluze, L; Lemaître, J

    1999-08-01

    The fixation of osteosynthesis screws remains a severe problem for fracture repair among osteoporotic patients. Polymethyl-methacrylate (PMMA) is routinely used to improve screw fixation, but this material has well-known drawbacks such as monomer toxicity, exothermic polymerization, and nonresorbability. Calcium phosphate cements have been developed for several years. Among these new bone substitution materials, brushite cements have the advantage of being injectable and resorbable. The aim of this study is to assess the reinforcement of osteosynthesis screws with brushite cement. Polyurethane foams, whose density is close to that of cancellous bone, were used as bone model. A hole was tapped in a foam sample, then brushite cement was injected. Trabecular osteosynthesis screws were inserted. After 24 h of aging in water, the stripping force was measured by a pull-out test. Screws (4.0 and 6.5 mm diameter) and two foam densities (0.14 and 0.28 g/cm3) were compared. Cements with varying solid/liquid ratios and xanthan contents were used in order to obtain the best screw reinforcement. During the pull-out test, the stripping force first increases to a maximum, then drops to a steady-state value until complete screw extraction. Both maximum force and plateau value increase drastically in the presence of cement. The highest stripping force is observed for 6.5-mm screws reinforced with cement in low-density foams. In this case, the stripping force is multiplied by 3.3 in the presence of cement. In a second experiment, cements with solid/liquid ratio ranging from 2.0 to 3.5 g/mL were used with 6.5-mm diameter screws. In some compositions, xanthan was added to improve injectability. The best results were obtained with 2.5 g/mL cement containing xanthan and with 3.0 g/mL cements without xanthan. A 0.9-kN maximal stripping force was observed with nonreinforced screws, while 1.9 kN was reached with reinforced screws. These first results are very promising regarding screw

  3. Assessing bone volume for orthodontic miniplate fixation below the maxillary frontal process.

    PubMed

    Präger, T M; Brochhagen, H G; Mischkowski, R; Jost-Brinkmann, P-G; Müller-Hartwich, R

    2014-09-01

    The maxillary bone below the frontal process is used for orthodontic anchorage; indications have included skeletally anchored protraction of the maxilla for treating Class III malocclusions or the intrusion of teeth in patients with a deep bite. This study was conducted to assess the condition of bone before cortically implanting miniplates in that area of the maxilla. A total of 51 thin-sliced computed tomography scans of 51 fully-dentate adult patients (mean age 24.0 ± 8.1 years; 27 men and 24 women) obtained prior to third-molar osteotomy were evaluated. Study parameters included total bone thickness, thickness of the facial cortical plate, and width of the nasal maxillary buttress. All these parameters were measured at different vertical levels. The bone volume adjacent to the piriform aperture was most pronounced at the basal level and decreased progressively toward more cranial levels. The basal bone structure had a mean total thickness of 7.8 mm, facial cortical plate thickness of 1.9 mm, and nasal maxillary buttress width of 9.2 mm. At 16 mm cranial to the aperture base, these values fell to 5.6 mm, 1.3 mm, and 5.8 mm, respectively. These bone measurements suggest that screws 7 mm in length can be inserted at the base level of the piriform aperture and screws 5 mm long at the cranial end of the bone.

  4. Achievable accuracy of hip screw holding power estimation by insertion torque measurement.

    PubMed

    Erani, Paolo; Baleani, Massimiliano

    2018-02-01

    To ensure stability of proximal femoral fractures, the hip screw must firmly engage into the femoral head. Some studies suggested that screw holding power into trabecular bone could be evaluated, intraoperatively, through measurement of screw insertion torque. However, those studies used synthetic bone, instead of trabecular bone, as host material or they did not evaluate accuracy of predictions. We determined prediction accuracy, also assessing the impact of screw design and host material. We measured, under highly-repeatable experimental conditions, disregarding clinical procedure complexities, insertion torque and pullout strength of four screw designs, both in 120 synthetic and 80 trabecular bone specimens of variable density. For both host materials, we calculated the root-mean-square error and the mean-absolute-percentage error of predictions based on the best fitting model of torque-pullout data, in both single-screw and merged dataset. Predictions based on screw-specific regression models were the most accurate. Host material impacts on prediction accuracy: the replacement of synthetic with trabecular bone decreased both root-mean-square errors, from 0.54 ÷ 0.76 kN to 0.21 ÷ 0.40 kN, and mean-absolute-percentage errors, from 14 ÷ 21% to 10 ÷ 12%. However, holding power predicted on low insertion torque remained inaccurate, with errors up to 40% for torques below 1 Nm. In poor-quality trabecular bone, tissue inhomogeneities likely affect pullout strength and insertion torque to different extents, limiting the predictive power of the latter. This bias decreases when the screw engages good-quality bone. Under this condition, predictions become more accurate although this result must be confirmed by close in-vitro simulation of the clinical procedure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Customized a Ti6Al4V Bone Plate for Complex Pelvic Fracture by Selective Laser Melting.

    PubMed

    Wang, Di; Wang, Yimeng; Wu, Shibiao; Lin, Hui; Yang, Yongqiang; Fan, Shicai; Gu, Cheng; Wang, Jianhua; Song, Changhui

    2017-01-04

    In pelvic fracture operations, bone plate shaping is challenging and the operation time is long. To address this issue, a customized bone plate was designed and produced using selective laser melting (SLM) technology. The key steps of this study included designing the customized bone plate, metal 3D printing, vacuum heat treatment, surface post-processing, operation rehearsal, and clinical application and evaluation. The joint surface of the bone plate was placed upwards with respect to the build platform to keep it away from the support and to improve the quality of the joint surface. Heat conduction was enhanced by adding a cone-type support beneath the bone plate to prevent low-quality fabrication due to poor heat conductivity of the Ti-6Al-4V powder. The residual stress was eliminated by exposing the SLM-fabricated titanium-alloy bone plate to a vacuum heat treatment. Results indicated that the bone plate has a hardness of HV1 360-HV1 390, an ultimate tensile strength of 1000-1100 MPa, yield strength of 900-950 MPa, and an elongation of 8%-10%. Pre-operative experiments and operation rehearsal were performed using the customized bone plate and the ABC-made pelvic model. Finally, the customized bone plate was clinically applied. The intraoperative C-arm and postoperative X-ray imaging results indicated that the customized bone plate matched well to the damaged pelvis. The customized bone plate fixed the broken bone and guides pelvis restoration while reducing operation time to about two hours. The customized bone plate eliminated the need for preoperative titanium plate pre-bending, thereby greatly reducing surgical wounds and operation time.

  6. Customized a Ti6Al4V Bone Plate for Complex Pelvic Fracture by Selective Laser Melting

    PubMed Central

    Wang, Di; Wang, Yimeng; Wu, Shibiao; Lin, Hui; Yang, Yongqiang; Fan, Shicai; Gu, Cheng; Wang, Jianhua; Song, Changhui

    2017-01-01

    In pelvic fracture operations, bone plate shaping is challenging and the operation time is long. To address this issue, a customized bone plate was designed and produced using selective laser melting (SLM) technology. The key steps of this study included designing the customized bone plate, metal 3D printing, vacuum heat treatment, surface post-processing, operation rehearsal, and clinical application and evaluation. The joint surface of the bone plate was placed upwards with respect to the build platform to keep it away from the support and to improve the quality of the joint surface. Heat conduction was enhanced by adding a cone-type support beneath the bone plate to prevent low-quality fabrication due to poor heat conductivity of the Ti-6Al-4V powder. The residual stress was eliminated by exposing the SLM-fabricated titanium-alloy bone plate to a vacuum heat treatment. Results indicated that the bone plate has a hardness of HV1 360–HV1 390, an ultimate tensile strength of 1000–1100 MPa, yield strength of 900–950 MPa, and an elongation of 8%–10%. Pre-operative experiments and operation rehearsal were performed using the customized bone plate and the ABC-made pelvic model. Finally, the customized bone plate was clinically applied. The intraoperative C-arm and postoperative X-ray imaging results indicated that the customized bone plate matched well to the damaged pelvis. The customized bone plate fixed the broken bone and guides pelvis restoration while reducing operation time to about two hours. The customized bone plate eliminated the need for preoperative titanium plate pre-bending, thereby greatly reducing surgical wounds and operation time. PMID:28772395

  7. Evaluation of Titanium-Coated Pedicle Screws: In Vivo Porcine Lumbar Spine Model.

    PubMed

    Kim, Do-Yeon; Kim, Jung-Ryul; Jang, Kyu Yun; Kim, Min Gu; Lee, Kwang-Bok

    2016-07-01

    Many studies have addressed the problem of loosening pedicle screws in spinal surgery, which is a serious concern. Titanium coating of medical implants (arthroplasty) is common, but few studies involving in vivo spine models have been reported. We evaluated the radiological, mechanical, and histological characteristics of titanium-coated pedicle screws compared with uncoated or hydroxyapatite-coated pedicle screws. Three different types of pedicle screws, i.e., uncoated, hydroxyapatite-coated, and titanium-coated, were implanted into the lumbar 3-4-5 levels of 9 mature miniature pigs. Radiological evaluation of loosening of pedicle screws was performed. Peak torsional extraction torque was tested in the 42 screws from 7 miniature pigs at 12 weeks postoperatively. The implant-bone interface of the remaining 12 pedicle screws from 2 miniature pigs in each group was assessed by micro-computed tomography and histologic studies. The incidence of loosening at 12 weeks postoperatively was not significantly different between the titanium-coated pedicle screw group and the other groups. The titanium-coated pedicle screw group exhibited the greatest mean extraction torsional peak torque at 12 weeks postoperatively (P < 0.05). Quantitative micro-computed tomography data were greatest in the titanium-coated pedicle screw group (P < 0.05). Histologic findings showed osteointegration with densely packed new bone formation at the screw coating-bone interface in the titanium-coated pedicle screw group. Fixation strength was greatest in the titanium-coated pedicle screw group. Osteointegration at the interface between the titanium-coated implant and bone produced prominent and firm bonding. The titanium-coated pedicle screw is a promising device for application in spinal surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    PubMed

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Notch sensitivity jeopardizes titanium locking plate fatigue strength.

    PubMed

    Tseng, Wo-Jan; Chao, Ching-Kong; Wang, Chun-Chin; Lin, Jinn

    2016-12-01

    Notch sensitivity may compromise titanium-alloy plate fatigue strength. However, no studies providing head-to-head comparisons of stainless-steel or titanium-alloy locking plates exist. Custom-designed identically structured locking plates were made from stainless steel (F138 and F1314) or titanium alloy. Three screw-hole designs were compared: threaded screw-holes with angle edges (type I); threaded screw-holes with chamfered edges (type II); and non-threaded screw-holes with chamfered edges (type III). The plates' bending stiffness, bending strength, and fatigue life, were investigated. The stress concentration at the screw threads was assessed using finite element analyses (FEA). The titanium plates had higher bending strength than the F1314 and F138 plates (2.95:1.56:1) in static loading tests. For all metals, the type-III plate fatigue life was highest, followed by type-II and type-I. The type-III titanium plates had longer fatigue lives than their F138 counterparts, but the type-I and type-II titanium plates had significantly shorter fatigue lives. All F1314 plate types had longer fatigue lives than the type-III titanium plates. The FEA showed minimal stress difference (0.4%) between types II and III, but the stress for types II and III was lower (11.9% and 12.4%) than that for type I. The screw threads did not cause stress concentration in the locking plates in FEA, but may have jeopardized the fatigue strength, especially in the notch-sensitive titanium plates. Improvement to the locking plate design is necessary. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Evaluation on Bending Properties of Biomaterial GUM Metal Meshed Plates for Bone Graft Applications

    NASA Astrophysics Data System (ADS)

    Suzuki, Hiromichi; He, Jianmei

    2017-11-01

    There are three bone graft methods for bone defects caused by diseases such as cancer and accident injuries: Autogenous bone grafts, Allografts and Artificial bone grafts. In this study, meshed GUM Metal plates with lower elasticity, high strength and high biocompatibility are introduced to solve the over stiffness & weight problems of ready-used metal implants. Basic mesh shapes are designed and applied to GUM Metal plates using 3D CAD modeling tools. Bending properties of prototype meshed GUM Metal plates are evaluated experimentally and analytically. Meshed plate specimens with 180°, 120° and 60° axis-symmetrical types were fabricated for 3-point bending tests. The pseudo bending elastic moduli of meshed plate specimens obtained from 3-point bending test are ranged from 4.22 GPa to 16.07 GPa, within the elasticity range of natural cortical bones from 2.0 GPa to 30.0 GPa. Analytical approach method is validated by comparison with experimental and analytical results for evaluation on bending property of meshed plates.

  11. Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep

    PubMed Central

    Wan, Shiyong; Wu, Zixiang; Liu, Da; Gao, Mingxuan; Fu, Suochao

    2010-01-01

    Transpedicular fixation can be challenging in the osteoporotic spine as reduced bone mineral density compromises the mechanical stability of the pedicle screw. Here, we sought to investigate the biomechanical and histological properties of stabilization of expandable pedicle screw (EPS) in the osteoporotic spine in sheep. EPSs and standard pedicle screws, SINO screws, were inserted on the vertebral bodies in four female ovariectomized sheep. Pull-out and cyclic bending resistance test were performed to compare the holding strength of these pedicle screws. High-resolution micro-computed tomography (CT) was performed for three-dimensional image reconstruction. We found that the EPSs provided a 59.6% increase in the pull-out strength over the SINO screws. Moreover, the EPSs withstood a greater number of cycles or load with less displacement before loosening. Micro-CT image reconstruction showed that the tissue mineral density, bone volume fraction, bone surface/bone volume ratio, trabecular thickness, and trabecular separation were significantly better in the expandable portion of the EPSs than those in the anterior portion of the SINO screws (P < 0.05). Furthermore, the trabecular architecture in the screw–bone interface was denser in the expandable portion of the EPS than that in the anterior portion of the SINO screw. Histologically, newly formed bone tissues grew into the center of EPS and were in close contact with the EPS. Our results show that the EPS demonstrates improved biomechanical and histological properties over the standard screw in the osteoporotic spine. The EPS may be of value in treating patients with osteoporosis and warrants further clinical studies. PMID:20577766

  12. Clinical, Morphological, and Molecular Evaluations of Bone Regeneration With an Additive Manufactured Osteosynthesis Plate.

    PubMed

    Thor, Andreas; Palmquist, Anders; Hirsch, Jan-Michaél; Rännar, Lars-Erik; Dérand, Per; Omar, Omar

    2016-10-01

    There is limited information on the biological status of bone regenerated with microvascular fibula flap combined with biomaterials. This paper describes the clinical, histological, ultrastructural, and molecular picture of bone regenerated with patient-customized plate, used for mandibular reconstruction in combination with microvascular osteomyocutaneous fibula flap. The plate was virtually planned and additively manufactured using electron beam melting. This plate was retrieved from the patient after 33 months. Microcomputed tomography, backscattered-scanning electron microscopy, histology, and quantitative-polymerase chain reaction were employed to evaluate the regenerated bone and the flap bone associated with the retrieved plate. At retrieval, the posterior two-thirds of the plate were in close adaptation with the underlying flap, whereas soft tissue was observed between the native mandible and the anterior one-third. The histological and structural analyses showed new bone regeneration, ingrowth, and osseointegration of the posterior two-thirds. The histological observations were supported by the gene expression analysis showing higher expression of bone formation and remodeling genes under the posterior two-thirds compared with the anterior one-third of the plate. The observation of osteocytes in the flap indicated its viability. The present data endorse the suitability of the customized, additively manufactured plate for the vascularized fibula mandibular reconstruction. Furthermore, the combination of the analytical techniques provides possibilities to deduce the structural and molecular characteristics of bone regenerated using this procedure.

  13. Defect nonunion of a metatarsal bone fracture in a cow: successful management with bone plating and autogenous cancellous bone graft.

    PubMed

    Raghunath, M; Singh, N; Singh, T; Gopinathan, A; Mohindroo, J; Atri, K

    2013-01-01

    A two-and-half-year-old cow was presented with a defect nonunion of the right metatarsal III/IV bone following a severely comminuted open fracture two months previously. The animal underwent open fixation using a 4.5 mm, broad, 10-hole, dynamic compression plate and autogenous cancellous bone graft collected from the contralateral iliac shaft. The animal started partial weight bearing after the third postoperative day and resumed complete weight bearing after the 10th day. Fracture healing was complete and the implants were removed after the 120th postoperative day. Stable fixation by means of a bone plate in conjunction with a cancellous bone graft facilitated complete healing and restoration of the bone column of the defect and the metatarsal fracture. The animal made a complete recovery.

  14. Virtual estimates of fastening strength for pedicle screw implantation procedures

    NASA Astrophysics Data System (ADS)

    Linte, Cristian A.; Camp, Jon J.; Augustine, Kurt E.; Huddleston, Paul M.; Robb, Richard A.; Holmes, David R.

    2014-03-01

    Traditional 2D images provide limited use for accurate planning of spine interventions, mainly due to the complex 3D anatomy of the spine and close proximity of nerve bundles and vascular structures that must be avoided during the procedure. Our previously developed clinician-friendly platform for spine surgery planning takes advantage of 3D pre-operative images, to enable oblique reformatting and 3D rendering of individual or multiple vertebrae, interactive templating, and placement of virtual pedicle implants. Here we extend the capabilities of the planning platform and demonstrate how the virtual templating approach not only assists with the selection of the optimal implant size and trajectory, but can also be augmented to provide surrogate estimates of the fastening strength of the implanted pedicle screws based on implant dimension and bone mineral density of the displaced bone substrate. According to the failure theories, each screw withstands a maximum holding power that is directly proportional to the screw diameter (D), the length of the in-bone segm,ent of the screw (L), and the density (i.e., bone mineral density) of the pedicle body. In this application, voxel intensity is used as a surrogate measure of the bone mineral density (BMD) of the pedicle body segment displaced by the screw. We conducted an initial assessment of the developed platform using retrospective pre- and post-operative clinical 3D CT data from four patients who underwent spine surgery, consisting of a total of 26 pedicle screws implanted in the lumbar spine. The Fastening Strength of the planned implants was directly assessed by estimating the intensity - area product across the pedicle volume displaced by the virtually implanted screw. For post-operative assessment, each vertebra was registered to its homologous counterpart in the pre-operative image using an intensity-based rigid registration followed by manual adjustment. Following registration, the Fastening Strength was computed

  15. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135º single-angled barrel plate for un-united and neglected femoral neck fractures.

    PubMed

    Gupta, Sameer; Kukreja, Sunil; Singh, Vivek

    2014-04-01

    To review the outcome of 60 patients who underwent valgus subtrochanteric osteotomy and its repositioning for un-united and neglected femoral neck fractures. 60 patients (mean age, 35 years) underwent valgus subtrochanteric osteotomy and repositioning of the osteotomy and fixation with a dynamic hip screw and a 135° single-angled barrel plate for closed un-united femoral neck fractures after failed internal fixation (n=27) or neglected (>3 weeks) fractures (n=33). The most common fracture type was transcervical (n=48), followed by subcapital (n=6) and basal (n=6). All patients had displaced femoral neck fractures (Garden types 3 and 4). According to the Pauwel angle, 45 fractures were type 2 (30º-70º) and 15 were type 3 (>70º). Patients were followed up for a mean of 3.5 (range, 2-7.5) years. The mean Pauwel angle of the fracture was corrected from 65° (range, 50°-89°) to 26° (range, 25°-28°). Bone union was achieved in 56 patients after a mean of 3.9 (range, 3-5.5) months. The mean Harris hip score improved from 65 to 87.5. Outcome was excellent in 30 patients, good in 24, and poor in 6. Four of the patients developed avascular necrosis; 2 of whom nonetheless achieved a good outcome. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135° single-angled barrel plate was effective treatment for un-united and neglected femoral neck fractures.

  16. A comparison of bicortical and intramedullary screw fixations of Jones' fractures.

    PubMed

    Husain, Zeeshan S; DeFronzo, Donna J

    2002-01-01

    Two different fixations for treatment of Jones' fracture were tested in bone models and cadaveric specimens to determine the differences in the stability of the constructs. A bicortical 3.5-mm cannulated cortical screw and an intramedullary 4.0-mm partially threaded cancellous screw were tested using physiologic loads with an Instron 8500 servohydraulic tensiometer (Instron Corporation, Canton, MA). In bone models, the bicortical construct (n = 5, 87+/-23 N) showed superior fixation strength (p = .0009) when compared to the intramedullary screw fixation (n = 5, 25+/-13 N). Cadaveric testing showed similar statistical significance (p = .0124) with the bicortical construct (n = 5, 152+/-71 N) having greater load resistance than the intramedullary screw fixation (n = 4, 29+/-20 N). In bone models, the bicortical constructs (23+/-9 N/mm) showed over twice the elastic modulus than the intramedullary screw fixations (9+/-4 N/mm) with statistical significance (p = .0115). The elastic modulus in the cadaveric group showed a similar pattern between the bicortical (19+/-17 N/mm) and intramedullary (9+/-6 N/mm) screw constructs. Analysis of the bicortical screw failure patterns revealed that screw orientation had a critical impact on fixation stability. The more distal the exit site of the bicortical screw was from the fracture site, the greater the load needed to displace the fixation.

  17. Single-stage reduction and fixation for atlantoaxial dislocation with atlas assimilation applying occipital plate, C2 screws and rigid cantilever beam system through intraoperative distraction: A retrospective study of 25 cases

    NASA Astrophysics Data System (ADS)

    Li, Zhonghua; Han, Xuesong; Li, Xiaolei; Qin, Xiaofei

    2018-04-01

    To report the surgical technique and clinical outcomes for the treatment of AAD with atlas assimilation by single-stage posterior reduction and fixation applying intraoperative distraction between occipital and C2 screws. From April 2008 to January 2014, 25 patients underwent single-stage posterior reduction and fixation applying occipital plate, C2 screws and rigid cantilever beam system through intraoperative distraction between occipital and C2 screws. The pre- and postoperative radiologic parameters and JOA score were examined. Follow-up ranged from 6 to 17months in 25 patients. Clinical symptoms improved in 24 patients (96%) and were stable in 1 patient (4%). Radiologic assessment illustrated that complete reduction was achieved in 24 patients and partial reduction (>60%) in 1 patient. Overall, satisfactory decompression and reduction were showed on postoperative MRT and 3D-CT scans of all 25 patients. The single-stage posterior reduction and fixation applying occipital plate, C2 screws and rigid cantilever beam system through intraoperative distraction between occipital and C2 screws for AAD with atlas assimilation is simple, fast, safe and effective. C1 screws insertion for the treatment of AAD with atlas assimilation should be considered.

  18. Application of a novel bone osteotomy plate leads to reduction in heat-induced bone tissue necrosis in sheep.

    PubMed

    Bekić, Marijo; Davila, Slavko; Hrskanović, Mato; Bekić, Marijana; Seiwerth, Sven; Erdeljić, Viktorija; Capak, Darko; Butković, Vladimir

    2008-12-01

    Previous studies have shown substantial effect thermal damage can have on new bone formation following osteotomy. In this study we evaluated the extent of thermal damage which occurs in four different methods of osteotomy and the effects it can have on bone healing. We further wanted to test whether a special osteotomy plate we constructed can lead to diminished heat generation during osteotomy and enhanced bone healing. The four methods evaluated included osteotomy performed by chisel, a newly constructed osteotomy plate, Gigly and oscillating saw. Twelve adult sheep underwent osteotomy performed on both tibiae. Bone fragments were stabilized using a fixation plate. Callus size was assessed using standard radiographs. Densitometry and histological evaluation were performed at 8 weeks following osteotomy. Temperature measurements were performed both in vivo during the operation, and ex vivo on explanted tibiae. The defects healed without complications and showed typical course of secondary fracture healing with callus ingrowth into the osteotomy gap. Radiographic examination of bone healing showed a tendency towards more callus formation in bones osteotomized using Gigly and oscillating saw, but this difference lacked significance. Use of Gigly and oscillating saw elicited much higher temperatures at the bone cortex surface, which subsequently lead to slightly impaired bone healing according to histological analysis. BMD was equal among all bones. In conclusion, the time required for complete healing of the defect differed depended greatly on the instruments used. The newly constructed osteotomy plate showed best results based on histological findings of capillary and osteoblast density.

  19. Experimental and numerical investigation into the influence of loading conditions in biomechanical testing of locking plate fracture fixation devices

    PubMed Central

    MacLeod, A.; Simpson, A. H. R. W.

    2018-01-01

    Objectives Secondary fracture healing is strongly influenced by the stiffness of the bone-fixator system. Biomechanical tests are extensively used to investigate stiffness and strength of fixation devices. The stiffness values reported in the literature for locked plating, however, vary by three orders of magnitude. The aim of this study was to examine the influence that the method of restraint and load application has on the stiffness produced, the strain distribution within the bone, and the stresses in the implant for locking plate constructs. Methods Synthetic composite bones were used to evaluate experimentally the influence of four different methods of loading and restraining specimens, all used in recent previous studies. Two plate types and three screw arrangements were also evaluated for each loading scenario. Computational models were also developed and validated using the experimental tests. Results The method of loading was found to affect the gap stiffness strongly (by up to six times) but also the magnitude of the plate stress and the location and magnitude of strains at the bone-screw interface. Conclusions This study demonstrates that the method of loading is responsible for much of the difference in reported stiffness values in the literature. It also shows that previous contradictory findings, such as the influence of working length and very large differences in failure loads, can be readily explained by the choice of loading condition. Cite this article: A. MacLeod, A. H. R. W. Simpson, P. Pankaj. Experimental and numerical investigation into the influence of loading conditions in biomechanical testing of locking plate fracture fixation devices. Bone Joint Res 2018;7:111–120. DOI: 10.1302/2046-3758.71.BJR-2017-0074.R2. PMID:29363522

  20. The Influence of Local Bone Density on the Outcome of One Hundred and Fifty Proximal Humeral Fractures Treated with a Locking Plate.

    PubMed

    Kralinger, Franz; Blauth, Michael; Goldhahn, Jörg; Käch, Kurt; Voigt, Christine; Platz, Andreas; Hanson, Beate

    2014-06-18

    There is biomechanical evidence that bone density predicts the mechanical failure of implants. The aim of this prospective study was to evaluate the influence of local bone mineral density on the rate of mechanical failure after locking plate fixation of proximal humeral fractures. We enrolled 150 patients who were from fifty to ninety years old with a closed, displaced proximal humeral fracture fixed with use of a locking plate from July 2007 to April 2010. There were 118 women and thirty-two men who had a mean age of sixty-nine years. Preoperative computed tomography (CT) scans were done to assess bone mineral density of the contralateral humerus, and dual x-ray absorptiometry of the distal end of the radius of the unaffected arm was conducted within the first six weeks postoperatively. At follow-up evaluations at six weeks, three months, and one year postoperatively, pain, shoulder mobility, strength, and multiple functional and quality-of-life outcome measures (Disabilities of the Arm, Shoulder and Hand [DASH] questionnaire; Shoulder Pain and Disability Index [SPADI]; Constant score; and EuroQuol-5D [EQ-5D]) were done and standard radiographs were made. We defined mechanical failure as all complications related to bone quality experienced within one year. After locking plate fixation, fifty-three (35%) of 150 patients had mechanical failure; loss of reduction and secondary screw loosening with perforation were common. CT assessments of local bone mineral density showed no difference between patients with and without mechanical failure (89.82 versus 91.51 mg/cm 3 , respectively; p = 0.670). One-year DASH, SPADI, and Constant scores were significantly better for patients without mechanical failure (p ≤ 0.05). We did not find evidence of an association between bone mineral density and the rate of mechanical failures, which may suggest that patients with normal bone mineral density are less prone to sustain a proximal humeral fracture. Future studies should

  1. Fracture Gap Reduction With Variable-Pitch Headless Screws.

    PubMed

    Roebke, Austin J; Roebke, Logan J; Goyal, Kanu S

    2018-04-01

    Fully threaded, variable-pitch, headless screws are used in many settings in surgery and have been extensively studied in this context, especially in regard to scaphoid fractures. However, it is not well understood how screw parameters such as diameter, length, and pitch variation, as well as technique parameters such as depth of drilling, affect gap closure. Acutrak 2 fully threaded variable-pitch headless screws of various diameters (Standard, Mini, and Micro) and lengths (16-28 mm) were inserted into polyurethane blocks of "normal" and "osteoporotic" bone model densities using a custom jig. Three drilling techniques (drill only through first block, 4 mm into second block, or completely through both blocks) were used. During screw insertion, fluoroscopic images were taken and later analyzed to measure gap reduction. The effect of backing the screw out after compression was evaluated. Drilling at least 4 mm past the fracture site reduces distal fragment push-off compared with drilling only through the proximal fragment. There were no significant differences in gap closure in the normal versus the osteoporotic model. The Micro screw had a smaller gap closure than both the Standard and the Mini screws. After block contact and compression with 2 subsequent full forward turns, backing the screw out by only 1 full turn resulted in gapping between the blocks. Intuitively, fully threaded headless variable-pitch screws can obtain compression between bone fragments only if the initial gap is less than the gap closed. Gap closure may be affected by drilling technique, screw size, and screw length. Fragment compression may be immediately lost if the screw is reversed. We describe characteristics of variable-pitch headless screws that may assist the surgeon in screw choice and method of use. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. Tensile behaviors of three-dimensionally free-formable titanium mesh plates for bone graft applications

    NASA Astrophysics Data System (ADS)

    He, Jianmei

    2017-11-01

    Present metal artificial bones for bone grafts have the problems like too heavy and excessive elastic modulus compared with natural bones. In this study, three-dimensionally (3D) free-formable titanium mesh plates for bone graft applications was introduced to improve these problems. Fundamental mesh shapes and patterns were designed under different base shapes and design parameters through three dimensional CAD tools from higher flexibility and strength points of view. Based on the designed mesh shape and patterns, sample specimens of titanium mesh plates with different base shapes and design variables were manufactured through laser processing. Tensile properties of the sample titanium mesh plates like volume density, tensile elastic modulus were experimentally and analytically evaluated. Experimental results showed that such titanium mesh plates had much higher flexibility and their mechanical properties could be controlled to close to the natural bones. More details on the mechanical properties of titanium mesh plates including compression, bending, torsion and durability will be carried out in future study.

  3. Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants.

    PubMed

    Berger-Gorbet, M; Broxup, B; Rivard, C; Yahia, L H

    1996-10-01

    NiTi is one of the most innovative concepts to have appeared in the field of metallic biomaterials in recent years but its biocompatibility remains controversial. We evaluated the biocompatibility of Nitinol screws using immunohistochemistry to observe the distribution of bone proteins during bone remodeling process around NiTi implant. Results were compared with screws made of Vitallium, c.p. titanium, Duplex austenitic-ferritic stainless steel (SAF), and Stainless Steel 316L. Screws were implanted in rabbit tibia for 3, 6, and 12 weeks. Embedding was performed in the hard resin Technovit, and for the immunohistochemical procedure undecalcified sections with bone-anchored implants could thus be used. The immunostaining method developed seemed to be a reliable technique to stain proteins in undecalcified sections. Biocompatibility results of the NiTi screws compared with the other screws showed a slower osteogenesis process characterized by no close contact between implant and bone, disorganized migration of osteoblasts around the implant, and a lower activity of osteonectin synthesis.

  4. A double-plating approach to distal femur fracture: A clinical study.

    PubMed

    Steinberg, Ely L; Elis, Jacov; Steinberg, Yohai; Salai, Moshe; Ben-Tov, Tomer

    2017-10-01

    Locked plating is one of the latest innovative options for treating supracondylar femur fractures with relatively low failure rates. Single lateral plating was often found to have a relative higher failure rate. No clinical studies of double-plating distal femur fixation have thus far been reported. The aim of this study is to present our clinical experience with this surgical approach. Thirty-two patients (26 females and 6 males, mean age 76 years, range 44-101) were included in the study. Eight of them patients had a periprosthetic stable implant fracture and two patients were treated for a nonunion. All fractures, excluding one that needed bone grafting and one refracture, healed within 12 weeks. One patient needed bone grafting for delayed union and one patient needed fixation exchange due to femur re-fracture at the site of the most proximal screw. Two patients developed superficial wound infection and one patient required medial plate removal after union due to deep infection. Based on these promising results, we propose that the double-plating technique should be considered in the surgeon's armamentarium for the treatment of supracondylar femur fractures, particularly in patients with poor bone quality, comminuted fractures and very low periprosthetic fractures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The use of blocking screws with internal lengthening nail and reverse rule of thumb for blocking screws in limb lengthening and deformity correction surgery.

    PubMed

    Muthusamy, Saravanaraja; Rozbruch, S Robert; Fragomen, Austin T

    2016-11-01

    Internal lengthening nail (ILN) is a recent development in limb lengthening and deformity correction specialty. The ILN has the distinct advantage of combining acute deformity correction with gradual lengthening of bone. While using ILN, the short metaphyseal bone fragment may develop a deformity at the time of osteotomy and nail insertion or during bone lengthening because of the wide medullary canal. These deformities are typically predictable, and blocking screws (Poller screws) are helpful in these situations. This manuscript describes the common deformities that occur in femur and tibia with osteotomies at different locations while using ILN in antegrade and retrograde nailing technique. Also, a systematic approach to the appropriate use of blocking screws in these deformities is described. In addition, the "reverse rule of thumb" is introduced as a quick reference to determine the ideal location(s) and number of blocking screws. These principles are applicable to limb lengthening and deformity correction as well as fracture fixation using intramedullary nails.

  6. Assessment of function-graded materials as fracture fixation bone-plates under combined loading conditions using finite element modelling.

    PubMed

    Fouad, H

    2011-05-01

    In previous work by Fouad (Medical Engineering and Physics 2010 [23]), 3D finite element (FE) models for fractured bones with function-graded (FG) bone-plates and traditional bone-plates made of stainless steel (SS) and titanium (Ti) alloy were examined under compressive loading conditions using the ABAQUS Code. In this study, the effects of the presence of the torsional load in addition to the compressive load on the predicted stresses of the fracture fixation bone-plate system are examined at different healing stages. The effects on the stress on the fracture site when using contacted and non-contacted bone-plate systems are also studied. The FE modelling results indicate that the torsional load has significant effects on the resultant stress on the fracture fixation bone-plate system, which should be taken into consideration during the design and the analysis. The results also show that the stress shielding at the fracture site decreases significantly when using FG bone-plates compared to Ti alloy or SS bone-plates. The presence of a gap between the bone and the plate results in a remarkable reduction in bone stress shielding at the fracture site. Therefore, the significant effects of using an FG bone-plate with a gap and the presence of torsional load on the resultant stress on the fracture fixation bone-plate system should be taken into consideration. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. [Efficacy of Sacroiliac Joint Anterior Approach with Double Reconstruction Plate and Computer Assisted Navigation Percutaneous Sacroiliac Screw for Treating Tile C1 Pelvic Fractures].

    PubMed

    Tan, Zhen; Fang, Yue; Zhang, Hui; Liu, Lei; Xiang, Zhou; Zhong, Gang; Huang, Fu-Guo; Wang, Guang-Lin

    2017-09-01

    To compare the efficacy of sacroiliac joint anterior approach with double reconstruction plate and computer assisted navigation percutaneous sacroiliac screw for treating Tile C1 pelvic fractures. Fifty patients with pelvic Tile C1 fractures were randomly divided into two groups ( n =25 for each) in the orthopedic department of West China Hospital of Sichuan University from December 2012 to November 2014. Patients in group A were treated by sacroiliac joint dislocation with anterior plate fixation. Patients in group B were treated with computerized navigation for percutaneous sacroiliac screw. The operation duration,intraoperative blood loss,incision length,and postoperative complications (nausea,vomiting,pulmonary infection,wound complications,etc.) were compared between the two groups. The postoperative fracture healing time,postoperative patient satisfaction,and postoperative fractures MATTA scores (to evaluate fracture reduction),postoperative MAJEED function scores,and SF36 scores of the patients were also recorded and compared. No significant differences in baseline characteristics were found between the two groups of patients. All of the patients in both groups had their operations successfully completed. Patients in group B had significantly shorter operations and lower intraoperative blood loss,incision length and postoperative complications than those in group A ( P <0.05). Patients in group B also had higher levels of satisfaction than those in group A ( P <0.05). No significant differences were found between the two groups in postoperative followup time,fracture healing time,postoperative MATTA scores,postoperative MAJEED function scores and SF36 scores ( P >0.05). Sacroiliac joint anterior approach with double reconstruction plate and computer assisted navigation percutaneous sacroiliac screws are both effective for treating Tile C1type pelvic fractures,with similar longterm efficacies. However,computer assisted navigation percutaneous sacroiliac screw

  8. Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system.

    PubMed

    Kaneyama, Shuichi; Sugawara, Taku; Sumi, Masatoshi

    2015-03-15

    Clinical trial for midcervical pedicle screw insertion using a novel patient-specific intraoperative screw guiding device. To evaluate the availability of the "Screw Guide Template" (SGT) system for insertion of midcervical pedicle screws. Despite many efforts for accurate midcervical pedicle screw insertion, there still remain unacceptable rate of screw malpositioning that might cause neurovascular injuries. We developed patient-specific SGT system for safe and accurate intraoperative screw navigation tool and have reported its availability for the screw insertion to C2 vertebra and thoracic spine. Preoperatively, the bone image on computed tomography was analyzed and the trajectories of the screws were designed in 3-dimensional format. Three types of templates were created for each lamina: location template, drill guide template, and screw guide template. During the operations, after engaging the templates directly with the laminae, drilling, tapping, and screwing were performed with each template. We placed 80 midcervical pedicle screws for 20 patients. The accuracy and safety of the screw insertion by SGT system were evaluated using postoperative computed tomographic scan by calculation of screw deviation from the preplanned trajectory and evaluation of screw breach of pedicle wall. All templates fitted the laminae and screw navigation procedures proceeded uneventfully. All screws were inserted accurately with the mean screw deviation from planned trajectory of 0.29 ± 0.31 mm and no neurovascular complication was experienced. We demonstrated that our SGT system could support the precise screw insertion in midcervical pedicle. SGT prescribes the safe screw trajectory in a 3-dimensional manner and the templates fit and lock directly to the target laminae, which prevents screwing error along with the change of spinal alignment during the surgery. These advantages of the SGT system guarantee the high accuracy in screw insertion, which allowed surgeons to insert

  9. Growth plate stress distribution implications during bone development: a simple framework computational approach.

    PubMed

    Guevara, J M; Moncayo, M A; Vaca-González, J J; Gutiérrez, M L; Barrera, L A; Garzón-Alvarado, D A

    2015-01-01

    Mechanical stimuli play a significant role in the process of long bone development as evidenced by clinical observations and in vivo studies. Up to now approaches to understand stimuli characteristics have been limited to the first stages of epiphyseal development. Furthermore, growth plate mechanical behavior has not been widely studied. In order to better understand mechanical influences on bone growth, we used Carter and Wong biomechanical approximation to analyze growth plate mechanical behavior, and explore stress patterns for different morphological stages of the growth plate. To the best of our knowledge this work is the first attempt to study stress distribution on growth plate during different possible stages of bone development, from gestation to adolescence. Stress distribution analysis on the epiphysis and growth plate was performed using axisymmetric (3D) finite element analysis in a simplified generic epiphyseal geometry using a linear elastic model as the first approximation. We took into account different growth plate locations, morphologies and widths, as well as different epiphyseal developmental stages. We found stress distribution during bone development established osteogenic index patterns that seem to influence locally epiphyseal structures growth and coincide with growth plate histological arrangement. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture.

    PubMed

    Knežević, Josip; Kodvanj, Janoš; Čukelj, Fabijan; Pamuković, Frane; Pavić, Arsen

    2017-11-01

    To compare the finite element models of two different composite radius fracture patterns, reduced and stabilised with four different fixed-angle dorsal plates during axial, dorsal and volar loading conditions. Eight different plastic models representing four AO/ASIF type 23-A3 distal radius fractures and four AO/ASIF 23-C2 distal radius fractures were obtained and fixed each with 1 of 4 methods: a standard dorsal non-anatomical fixed angle T-plate (3.5mm Dorsal T-plate, Synthes), anatomical fixed-angle double plates (2.4mm LCP Dorsal Distal Radius, Synthes), anatomical fixed angle T-plate (2.4mm Acu-Loc Dorsal Plate, Acumed) or anatomical variable-angle dorsal T-plate (3.5mm, Dorsal Plate, Zrinski). Composite radius with plate and screws were scanned with a 3D optical scanner and later processed in Abaqus Software to generate the finite element model. All models were axially loaded at 3 points (centrally, volarly and dorsally) with 50 N forces to avoid the appearance of plastic deformations of the models. Total displacements at the end of the bone and the stresses in the bones and plates were determined and compared. Maximal von Mises stress in bone for 3-part fracture models was very similar to that in 2-part fracture models. The biggest difference between models and the largest displacements were seen during volar loading. The stresses in all models were the highest above the fracture gap. The best performance in all parameters tested was with the Zrinski plate and the most modest results were with the Synthes T-plate. There was no significant difference between 2-part (AO/ASIF type 23-A3) and 3-part (AO/ASIF 23-C2) fracture models. Maximal stresses in the plates appeared above the fracture gap; therefore, it is worth considering the development of plates without screw holes above the gap. © 2017 Elsevier Ltd. All rights reserved.

  11. Intramedullary nails with two lag screws.

    PubMed

    Brown, C J; Wang, C J; Yettram, A L; Procter, P

    2004-06-01

    To investigate the structural integrity of intramedullary nails with two lag screws, and to give guidance to orthopaedic surgeons in the choice of appropriate devices. Alternative designs of the construct are considered, and the use of a slotted upper lag screw insertion hole is analysed. Intramedullary fixation devices with a single lag screw have been known to fail at the lag screw insertion hole. Using two lag screws is considered. It has also been proposed to use a slot in the nail for the upper lag screw to prevent the upper lag screw from sticking. Bending and torsion load cases are analysed using finite element method. Consideration of both load conditions is essential. The results present the overall stiffness of the assembly, the load sharing between lag screws, and the possibility for cut-out to occur. While the slot for the upper lag screw might be advantageous with regard to the stresses in the lag screws, it could be detrimental for cut-out occurring adjacent to the lag screws. Comparative analyses demonstrate that two lag screws may be advantageous in patients whose cancellous bone quality is good and who impose large loads on the lag screw/nail interface. However, the use of two screws might pre-dispose to failure by cut-out of the lag screws. The addition of a slotted hole for the upper lag screw appears to do nothing significant to reduce the risk of such a failure. Copyright 2004 Elsevier Ltd.

  12. The Biocompatibility of Degradable Magnesium Interference Screws: An Experimental Study with Sheep

    PubMed Central

    Thormann, Ulrich; Alt, Volker; Heimann, Lydia; Gasquere, Cyrille; Heiss, Christian; Szalay, Gabor; Franke, Jörg; Schnettler, Reinhard; Lips, Katrin Susanne

    2015-01-01

    Screws for ligament reconstruction are nowadays mostly made of poly-L-lactide (PLLA). However, magnesium-based biomaterials are gathering increased interest in this research field because of their good mechanical property and osteoanabolic influence on bone metabolism. The aim of this pilot study was to evaluate the biocompatibility of an interference screw for ligament reconstruction made of magnesium alloy W4 by diecasting and milling and using different PEO-coatings with calcium phosphates. PLLA and titanium screws were used as control samples. The screws were implanted in the femur condyle of the hind leg of a merino sheep. The observation period was six and twelve weeks and one year. Histomorphometric, immunohistochemical, immunofluorescence, and molecular biological evaluation were conducted. Further TEM analysis was done. In all magnesium screws a clinically relevant gas formation in the vicinity of the biomaterial was observed. Except for the PLLA and titanium control samples, no screw was fully integrated in the surrounding bone tissue. Regarding the fabrication process, milling seems to produce less gas liberation and has a better influence on bone metabolism than diecasting. Coating by PEO with calcium phosphates could not reduce the initial gas liberation but rather reduced the bone metabolism in the vicinity of the biomaterial. PMID:25717474

  13. Partial growth plate closure: apex view on bone scan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howman-Giles, R.; Trochei, M.; Yeates, K.

    1985-01-01

    A new technique of using /sup 99m/Tc bone scan to assess partial closure of the growth plate is described. The site and degree of osseous fusion can be obtained by using the apex view. The technique has the potential of assessing serially the growth of a plate before and after surgery.

  14. Comparative study of subtalar arthrodesis after calcaneal frature malunion with autologous bone graft or freeze-dried xenograft.

    PubMed

    Henning, Carlo; Poglia, Gabriel; Leie, Murilo Anderson; Galia, Carlos Roberto

    2015-12-01

    Calcaneal fracture malunion may evolve into arthrosis and severe foot deformities. The aim of this study was to identify differences in bony union following corrective subtalar arthrodesis with interposition of autologous tricortical bone graft or freeze-dried bovine xenograft. We prospectively evaluated 12 patients who underwent subtalar arthrodesis, six patients received autografts and 6 received freeze-dried bovine xenografts. After a mean followup of 58 weeks, the patients were clinical assessed using AOFAS scale and the visual analog scale (VAS) for pain and for final radiographic parameters measurement. Two blind raters evaluated the length of time required for solid union of the arthrodesis and graft integration by retrospective radiographic examination. In the autograft group, AOFAS score improved from a preoperative average of 37 to 64 points postoperatively (p = 0.02) and mean VAS score improved from 4.7 to 1.9 (p = 0.028). In the xenograft group, AOFAS score improved from 38 to 74 points (p = 0.02) and VAS from 5.5 to 2.7 (p = 0.046). Solid union was achieved in all cases in the autograft group at an average of 5.3 weeks and in five cases in the xenograft group at 8.8 weeks (p = 0.077). Graft integration occurred after an average of 10.7 weeks in the autograft group and 28.8 weeks in the xenograft group (p = 0.016). With the numbers available, no significant difference could be detected in the length of time required for solid union of subtalar arthrodesis between groups, although time to integration of freeze-dried bovine xenografts was statistically higher. Clinical and functional improvement was observed in both groups.

  15. Long-term degradation of a poly-lactide co-glycolide/β-tricalcium phosphate biocomposite interference screw.

    PubMed

    Barber, F Alan; Dockery, W D; Hrnack, Scott A

    2011-05-01

    To evaluate the long-term in vivo degradation of biodegradable interference screws made of poly-L-lactide co-glycolide (poly-L-lactic acid [PLLA]/polyglycolic acid [PGA]) and β-tricalcium phosphate (β-TCP). To study in vivo the biological behavior of a PLLA/PGA/β-TCP biocomposite screw (Milagro; DePuy Mitek, Raynham, MA), an institutional review board-approved program using anterior cruciate ligament (ACL) interference fixation screws was initiated in 2005. Thirteen patients who had bone-patellar tendon-bone ACL reconstruction fixed at both the femur and tibia with PLLA/PGA/β-TCP screws at least 24 months earlier were evaluated by physical, radiographic, and computed tomography (CT) evaluations. Lysholm, Tegner, Cincinnati, and International Knee Documentation Committee scores were also obtained. Radiographs and CT scans of the operated knee were obtained. CT scan data measured in Hounsfield units (HU) evaluated the material density at the screw and bone plug sites. Soft-tissue and cancellous and cortical bone site readings were also taken. Osteoconductivity scores were determined at the screw sites by use of an ossification quality score (range, 1 to 4). Eleven men and two women were evaluated at a mean of 38 months after surgery (range, 24 to 49 months). CT scans and radiographs showed the bone plug fused to the tunnel wall with no PLLA/PGA/β-TCP screw remaining. The screws were replaced with material that was calcified and non-trabecular. Osteoconductivity was present in 21 of 26 tunnels (81%) and complete (type 4 ossification) in 5 of 26 (19%). Mean screw site densities (femoral, 159 HU; tibial, 157 HU) were not different from the mean cancellous bone density (femoral, 146 HU; tibial, 140 HU). No positive pivot-shift tests were found. Lysholm, Tegner, and Cincinnati scores improved from 44, 3.7, and 37 preoperatively to 93, 6, and 87 at follow-up, respectively. The mean KT arthrometer (MEDmetric, San Diego, CA) difference was 0.8 mm. The PLLA

  16. [Arthrodesis of the shoulder. A new and soft-tissue-sparing technique with a deep locking plate in the supraspinatus fossa].

    PubMed

    Klonz, A; Habermeyer, P

    2007-10-01

    Arthrodesis of the glenohumeral joint is a difficult intervention that involves a relatively high probability of complications. A stable internal fixation and secure consolidation is required. The operation needs to achieve several conditions: thorough denudation of the cartilage and partial decortication of the subchondral bone; good congruence of the corresponding surfaces; compression of the gap by tension screws and lasting stability. For increased primary stability a neutralizing plate is generally used as well as a compression screw. Up to now, the plate has usually been applied starting from the scapular spine and extending across the acromial corner to the humeral shaft. A wide exposure is needed for this procedure; the plate is difficult to shape during the operation and often causes some discomfort because it protrudes at the acromial corner. We present an alternative position of the plate in the supraspinatus fossa, where we have sited a 4.5 mm LCP locking plate (Synthes). The implant is inserted under the acromion, does not cause any discomfort at the acromial corner, and is far easier to shape. When it is used in association with a transarticular compressive screw, the technique results in a very stable situation, which allows physiotherapy from the first day after surgery onward.

  17. Radiological analysis of minimal safe distance and optimal screw angle to avoid facet violation in open-door laminoplasty using precontoured plate.

    PubMed

    Min, Woo-Kie; Seo, Il; Na, Sang-Bong; Choi, Young-Seo; Choi, Ji-Yeon

    2017-01-01

    This study aimed to present radiologic analysis of minimal safe distance (MSD) and optimal screw angle (OSA) that enables to fix screws in a lateral mass safely without facet joint violation in open-door laminoplasty using a plate. A retrospective analysis was made of 22 patients (male: 17; female: 5), average age 62 years. Seventy-nine lateral mass screws were fixed among a total of 158 screws. MSD that doesn't allow 5-mm screws to violate a facet joint was measured for C3-C7 and a comparative analysis was performed. If the MSD is not secured, the OSA to be given to the cephalad direction is calculated to avoid violation of the facet joint. The screws violating inferior facet joints accounted for 34.1% of the screws fixed in inferior lateral mass. Joint surface to distal mini-screw distances were 3.18 ± 1.46 mm and 4.75 ± 1.71 mm in groups of facet joint violation and non-facet violation (FV), respectively ( p = 0.001). When 5-mm screws were inserted into a lateral mass, MSD was 4.39 ± 0.83 mm. The average MSD of C3, C4, and C5 was 4.05 ± 0.78 mm, 4.10 ± 0.70 mm, and 4.26 ± 0.74 mm, respectively. There was no significant differences among levels ( p > 0.05). The average MSD of C6 and C7 was 4.92 ± 0.81 mm and 4.80 ± 0.96 mm, respectively, showing significant differences from those of C3, C4, and C5 ( p < 0.05). If 6 mm of the MSD isn't secured, OSA showed in the cephalad direction of 11.5° for 5 mm and 22° for 4 mm approximately. We suggest that mini-screw on lateral mass can be fixed safely without FV, if they are fixed at MSD of 6 mm from a joint surface. Facet joint violation doesn't occur if an OSA is given in the cephalad direction in case of not enough MSD for mini-screws.

  18. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.

    PubMed

    Kawaguchi, Yoshiharu; Nakano, Masato; Yasuda, Taketoshi; Seki, Shoji; Hori, Takeshi; Kimura, Tomoatsu

    2012-11-01

    We developed a new technique for cervical pedicle screw and Magerl screw insertion using a 3-dimensional image guide. In posterior cervical spinal fusion surgery, instrumentation with screws is virtually routine. However, malpositioning of screws is not rare. To avoid complications during cervical pedicle screw and Magerl screw insertion, the authors developed a new technique which is a mold shaped to fit the lamina. Cervical pedicle screw fixation and Magerl screw fixation provide good correction of cervical alignment, rigid fixation, and a high fusion rate. However, malpositioning of screws is not a rare occurrence, and thus the insertion of screws has a potential risk of neurovascular injury. It is necessary to determine a safe insertion procedure for these screws. Preoperative computed tomographic (CT) scans of 1-mm slice thickness were obtained of the whole surgical area. The CT data were imported into a computer navigation system. We developed a 3-dimensional full-scale model of the patient's spine using a rapid prototyping technique from the CT data. Molds of the left and right sides at each vertebra were also constructed. One hole (2.0 mm in diameter and 2.0 cm in length) was made in each mold for the insertion of a screw guide. We performed a simulated surgery using the bone model and the mold before operation in all patients. The mold was firmly attached to the surface of the lamina and the guide wire was inserted using the intraoperative image of lateral vertebra. The proper insertion point, direction, and length of the guide were also confirmed both with the model bone and the image intensifier in the operative field. Then, drilling using a cannulated drill and tapping using a cannulated tapping device were carried out. Eleven consecutive patients who underwent posterior spinal fusion surgery using this technique since 2009 are included. The screw positions in the sagittal and axial planes were evaluated by postoperative CT scan to check for

  19. The effect of load obliquity on the strength of locking and nonlocking constructs in synthetic osteoporotic bone.

    PubMed

    Tensmeyer, Daniel F; Gustafson, Peter A; Jastifer, James R; Patel, Bipin; Chess, Joseph L

    2015-11-01

    The biomechanical performance of internal fracture fixation depends on several factors. One measure of performance is the strength of the construct. The objective of this biomechanical study was to identify the effect of load obliquity on the strength of locking and nonlocking plate and screw constructs. For this study, plates and screws were fixed to synthetic osteoporotic bone that had a 1 mm thick synthetic cortical shell. An 8-hole, 3.5 mm thick hybrid plate was fixed with either two 3.5 mm major diameter locking screws or two 4.0 mm major diameter cancellous screws. Forces were applied at 0, 45, and 90 degrees to the plate normal. Eight specimens were loaded to failure for each group. When loads were applied normal to the plate, the nonlocking construct failed initially at higher loads (123.2 ± 13.2 N) than the locking construct (108.7 ± 7.6 N, P = 0.020). For oblique loads, the locking construct failed at higher mean loads but the difference of means was not statistically significant (167.7 ± 14.9 N compared to 154.2 ± 9.4 N, P = 0.052). For loads parallel to the plate, the locking construct was much stronger than the nonlocking construct (1591 ± 227 N compared to 913 ± 237 N, P < 0.001). Stiffness and Energy outcomes are also compared. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. [Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

    PubMed

    Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel

    2013-01-01

    This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.

  1. The use of power tools in the insertion of cortical bone screws.

    PubMed

    Elliott, D

    1992-01-01

    Cortical bone screws are commonly used in fracture surgery, most patterns are non-self-tapping and require a thread to be pre-cut. This is traditionally performed using hand tools rather than their powered counterparts. Reasons given usually imply that power tools are more dangerous and cut a less precise thread, but there is no evidence to support this supposition. A series of experiments has been performed which show that the thread pattern cut with either method is identical and that over-penetration with the powered tap is easy to control. The conclusion reached is that both methods produce consistently reliable results but use of power tools is much faster.

  2. Virtual plate pre-bending for the long bone fracture based on axis pre-alignment.

    PubMed

    Liu, Bin; Luo, Xinjian; Huang, Rui; Wan, Chao; Zhang, Bingbing; Hu, Weihua; Yue, Zongge

    2014-06-01

    In this paper, a modeling and visualizing system for assisting surgeons in correctly registering for the closed fracture reduction surgery is presented. By using this system, the geometric parameters of the target fixation plate before the long bone fracture operation can be obtained. The main processing scheme consists of following steps: firstly (image data process), utilize the Curvelet transform to denoise the CT images of fracture part and then reconstruct the 3D models of the broken bones. Secondly (pre-alignment), extract the axial lines of the broken bones and spatially align them. Then drive the broken bone models to be pre-aligned. Thirdly (mesh segmentation), a method based on vertex normal feature is utilized to obtain the broken bone cross-sections mesh models. Fourthly (fine registration), the ICP (Iterative Closest Point) algorithm is used to register the cross-sections and the broken bone models are driven to achieve the fine registration posture. Lastly (plate fitting), an accurate NURBS surface fitting method is used to construct the virtual plate. The experiment proved that the obtained models of the pre-bended plates were closely bonded to the surface of the registered long bone models. Finally, the lengths, angles and other interested geometric parameters can be measured on the plate models. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Arthroscopy-assisted reduction of posteromedial tibial plateau fractures with buttress plate and cannulated screw construct.

    PubMed

    Chiu, Chih-Hao; Cheng, Chun-Ying; Tsai, Min-Chain; Chang, Shih-Sheng; Chen, Alvin Chao-Yu; Chen, Yeung-Jen; Chan, Yi-Sheng

    2013-08-01

    To present the radiologic and clinical results of posteromedial fractures treated with arthroscopy-assisted reduction and buttress plate and cannulated screw fixation. Twenty-five patients with posteromedial tibial plateau fractures treated by the described technique were included in this study. According to the Schatzker classification, there were 5 type IV fractures (20%), 2 type V fractures (8%), and 18 type VI fractures (72%). The mean age at operation was 46 years (range, 21 to 79 years). The mean follow-up period was 86 months (range, 60 to 108 months). Clinical and radiologic outcomes were scored by the Rasmussen system. Subjective data were collected to assess swelling, difficulty climbing stairs, joint stability, ability to work and participate in sports, and overall patient satisfaction with recovery. Secondary osteoarthritis was diagnosed when radiographs showed a narrowed joint space in the injured knee at follow-up in comparison with the films taken at the time of injury. The mean postoperative Rasmussen clinical score was 25.9 (range, 18 to 29), and the mean radiologic score was 15.8 (range, 10 to 18). All 25 fractures achieved successful union, and 92% had good or excellent clinical and radiologic results. The 3 fracture types did not significantly differ in Rasmussen scores or rates of satisfactory results (P > .05). Secondary osteoarthritis was noted in 6 injured knees (24%). Arthroscopy-assisted reduction with buttress plate and cannulated screw fixation can restore posteromedial tibial plateau fractures of the knee with well-documented radiographic healing, good clinical outcomes, and low complication rates. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. Importance of a moderate plate-to-bone distance for the functioning of the far cortical locking system.

    PubMed

    Yang, Jesse Chieh-Szu; Lin, Kang-Ping; Wei, Hung-Wen; Chen, Wen-Chuan; Chiang, Chao-Ching; Chang, Ming-Chau; Tsai, Cheng-Lun; Lin, Kun-Jhih

    2018-06-01

    The far cortical locking (FCL) system, a novel bridge-plating technique, aims to deliver controlled and symmetric interfragmentary motion for a potential uniform callus distribution. However, clinical data for the practical use of this system are limited. The current study investigated the biomechanical effect of a locking plate/far cortical locking construct on a simulated comminuted diaphyseal fracture of the synthetic bones at different distance between the plate and the bone. Biomechanical in vitro experiments were performed using composite sawbones as bone models. A 10-mm osteotomy gap was created and bridged with FCL constructs to determine the construct stiffness, strength, and interfragmentary movement under axial compression, which comprised one of three methods: locking plates applied flush to bone, at 2 mm, or at 4 mm from the bone. The plate applied flush to the bone exhibited higher stiffness than those at 2 mm and 4 mm plate elevation. A homogeneous interfragmentary motion at the near and far cortices was observed for the plate at 2 mm, whereas a relatively large movement was observed at the far cortex for the plate applied at 4 mm. A plate-to-bone distance of 2 mm had the advantages of reducing axial stiffness and providing nearly parallel interfragmentary motion. The plate flush to the bone prohibits the dynamic function of the far cortical locking mechanism, and the 4-mm offset was too unstable for fracture healing. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Growth plate-derived hedgehog-signal-responsive cells provide skeletal tissue components in growing bone.

    PubMed

    Haraguchi, Ryuma; Kitazawa, Riko; Imai, Yuuki; Kitazawa, Sohei

    2018-04-01

    Longitudinal bone growth progresses by continuous bone replacement of epiphyseal cartilaginous tissue, known as "growth plate", produced by columnar proliferated- and differentiated-epiphyseal chondrocytes. The endochondral ossification process at the growth plate is governed by paracrine signals secreted from terminally differentiated chondrocytes (hypertrophic chondrocytes), and hedgehog signaling is one of the best known regulatory signaling pathways in this process. Here, to investigate the developmental relationship between longitudinal endochondral bone formation and osteogenic progenitors under the influence of hedgehog signaling at the growth plate, genetic lineage tracing was carried out with the use of Gli1 CreERT2 mice line to follow the fate of hedgehog-signal-responsive cells during endochondral bone formation. Gli1 CreERT2 genetically labeled cells are detected in hypertrophic chondrocytes and osteo-progenitors at the chondro-osseous junction (COJ); these progeny then commit to the osteogenic lineage in periosteum, trabecular and cortical bone along the developing longitudinal axis. Furthermore, in ageing bone, where longitudinal bone growth ceases, hedgehog-signal responsiveness and its implication in osteogenic lineage commitment is significantly weakened. These results show, for the first time, evidence of the developmental contribution of endochondral progenitors under the influence of epiphyseal chondrocyte-derived secretory signals in longitudinally growing bone. This study provides a precise outline for assessing the skeletal lineage commitment of osteo-progenitors in response to growth-plate-derived regulatory signals during endochondral bone formation.

  6. Treatment of segmental tibial fractures with supercutaneous plating.

    PubMed

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  7. Metallic fragments on the surface of miniplates and screws before insertion.

    PubMed

    Ray, M S; Matthew, I R; Frame, J W

    1999-02-01

    Particulate metal fragments have been identified histologically within the tissues adjacent to miniplates and screws after they have been removed. These were thought to have been caused by corrosion and degradation of the metal. However, the particles may have originated from rough edges or from protuberances left on the metal surface after cutting and machining during manufacture, and subsequently become detached. This study was undertaken to analyse the incidence and distribution of metal fragments on the surface of miniplates and screws before use. Fifteen miniplates and 60 screws were examined by stereomicroscopy and scanning electron microscopy. Rough metal edges or protuberances were identified on over half the samples, mostly in the countersink area of screw holes on the mini-plates. Fragments were detected within some of the cruciform screw heads and on some screw threads. We conclude that metal protuberances are present on the surface of mini-plate components when they are received from the manufacturer. There is a risk that the fragments might be detached and deposited into the tissues during insertion.

  8. End-threaded intramedullary positive profile screw ended self-tapping pin (Admit pin) - A cost-effective novel implant for fixing canine long bone fractures.

    PubMed

    Chanana, Mitin; Kumar, Adarsh; Tyagi, Som Prakash; Singla, Amit Kumar; Sharma, Arvind; Farooq, Uiase Bin

    2018-02-01

    The current study was undertaken to evaluate the clinical efficacy of end-threaded intramedullary pinning for management of various long bone fractures in canines. This study was conducted in two phases, managing 25 client-owned dogs presented with different fractures. The technique of application of end-threaded intramedullary pinning in long bone fractures was initially standardized in 6 clinical patients presented with long bone fractures. In this phase, end-threaded pins of different profiles, i.e., positive and negative, were used as the internal fixation technique. On the basis of results obtained from standardization phase, 19 client-owned dogs clinically presented with different fractures were implanted with end-threaded intramedullary positive profile screw ended self-tapping pin in the clinical application phase. The patients, allocated randomly in two groups, when evaluated postoperatively revealed slight pin migration in Group-I (negative profile), which resulted in disruption of callus site causing delayed union in one case and large callus formation in other two cases whereas no pin migration was observed in Group-II (positive profile). Other observations in Group-I was reduced muscle girth and delayed healing time as compared to Group-II. In clinical application, phase 21 st and 42 nd day post-operative radiographic follow-up revealed no pin migration in any of the cases, and there was no bone shortening or fragment collapse in end-threaded intramedullary positive profile screw ended self-tapping pin. The end-threaded intramedullary positive profile screw ended self-tapping pin used for fixation of long bone fractures in canines can resist pin migration, pin breakage, and all loads acting on the bone, i.e., compression, tension, bending, rotation, and shearing to an extent with no post-operative complications.

  9. Biomechanical evaluation of a second generation headless compression screw for ankle arthrodesis in a cadaver model.

    PubMed

    Somberg, Andrew Max; Whiteside, William K; Nilssen, Erik; Murawski, Daniel; Liu, Wei

    2016-03-01

    Many types of screws, plates, and strut grafts have been utilized for ankle arthrodesis. Biomechanical testing has shown that these constructs can have variable stiffness. More recently, headless compression screws have emerged as an evolving method of achieving compression in various applications but there is limited literature regarding ankle arthrodesis. The aim of this study was to determine the biomechanical stability provided by a second generation fully threaded headless compression screw compared to a standard headed, partially threaded cancellous screw in a cadaveric ankle arthrodesis model. Twenty fresh frozen human cadaver specimens were subjected to simulated ankle arthrodesis with either three standard cancellous-bone screws (InFix 7.3mm) or with three headless compression screws (Acumed Acutrak 2 7.5mm). The specimens were subjected to cyclic loading and unloading at a rate of 1Hz, compression of 525 Newtons (N) and distraction of 20N for a total of 500 cycles using an electromechanical load frame (Instron). The amount of maximum distraction was recorded as well as the amount of motion that occurred through 1, 10, 50, 100, and 500 cycles. No significant difference (p=0.412) was seen in the amount of distraction that occurred across the fusion site for either screw. The average maximum distraction after 500 cycles was 201.9μm for the Acutrak 2 screw and 235.4μm for the InFix screw. No difference was seen throughout each cycle over time for the Acutrak 2 screw (p-value=0.988) or the InFix screw (p-value=0.991). Both the traditional InFix type screw and the second generation Acumed Acutrak headless compression screws provide adequate fixation during ankle arthrodesis under submaximal loads. There is no demonstrable difference between traditional cannulated partially threaded screws and headless compression screws studied in this model. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  10. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    PubMed

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p < .05). Locking and non-locking double-row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  11. Experimental investigation of the fracture torque of orthodontic anchorage screws.

    PubMed

    Reimann, Susanne; Ayubi, Mustafa; McDonald, Fraser; Bourauel, Christoph

    2016-07-01

    In contrast to dental implants that remain in the bone, orthodontic anchorage screws serve as temporary anchorage for orthodontic tooth movement and are removed after completion of treatment. The aim of the present study was to evaluate the stability of various commercially available orthodontic anchorage screws against torsion. The torsional deflection of ten different orthodontic anchorage screws from different manufacturers [Ortho Easy Pin (Forestadent), Benefit, quattro (both PSM Medical Solutions), Vector TAS (Ormco), AbsoAnchor(®) (DENTOS Inc.), OrthoLox, Dual-Top JA (both Promedia Medizintechnik), TAD (3M Unitek), INFINITAS (ODS) and tomas(®) (Dentaurum)] was tested in vitro in relation to the rotation angle using a self-developed set-up. The screws were positioned in a resin model with bone-like material properties. Shear tests were performed using the manufacturers' own screwdrivers. Ten screws each were turned manually until a sudden drop in the measured torque occurred. At this point, the screw head was twisted off. Fracture torque and the torque at which the screws deformed plastically were evaluated. Mean values and standard deviations were calculated. According to the German industrial standard, the torque of orthodontic anchorage screws should reach at least 20 Ncm. The majority of the screws reached this nominal torque; however, a few screws fractured before reaching this value. Five screw types displayed plastic deformation below the threshold, at approximately 16 Ncm. The results suggest that orthodontic anchorage screws generally meet the requirements of the standard and ensure safe clinical use. However, according to the present data, it may be assumed that a portion of the screws will be plastically deformed upon removal.

  12. Metachronous bilateral subtrochanteric fracture of femur in an osteopetrotic bone: A case report with technical note.

    PubMed

    Kumar, Dharmendra; Jain, Vijay Kumar; Lal, Hitesh; Arya, Rajinder Kumar; Sinha, Skand

    2012-12-01

    Osteopetrosis is a rare inherited skeletal disorder characterized by increased density. The increased fragility of such dense bone results in a greater incidence of fractures, especially around hip and proximal femur. The surgical treatment of such fractures is difficult due to hard but brittle structure of bone. Herein we report a case of bilateral subtrochanteric fracture in an osteopetrotic patient. It was fixed using a dynamic hip screw with plate.

  13. Development of an optically-based tension-indicating implanted orthopedic screw with a luminescent spectral ruler

    NASA Astrophysics Data System (ADS)

    Ravikumar, Nakul; Rogalski, Melissa M.; Benza, Donny; Lake, Joshua; Urban, Matthew; Pelham, Hunter; Anker, Jeffrey N.; DesJardins, John D.

    2017-03-01

    An orthopaedic screw was designed with an optical tension-indicator to non-invasively quantify screw tension and monitor the load sharing between the bone and the implant. The screw both applies load to the bone, and measures this load by reporting the strain on the screw. The screw contains a colorimetric optical encoder that converts axial strain into colorimetric changes visible through the head of the screw, or luminescent spectral changes that are detected through tissue. Screws were tested under cyclic mechanical loading to mimic in-vivo conditions to verify the sensitivity, repeatability, and reproducibility of the sensor. In the absence to tissue, color was measured using a digital camera as a function of axial load on a stainless steel cannulated (hollow) orthopedic screw, modified by adding a passive colorimetric strain gauge through the central hole. The sensor was able to quantify clinically-relevant bone healing strains. The sensor exhibited good repeatability and reproducibility but also displayed hysteresis due to the internal mechanics of the screw. The strain indicator was also modified for measurement through tissue by replacing the reflective colorimetric sensor with a low-background X-ray excited optical luminescence signal. Luminescent spectra were acquired through 6 mm of chicken breast tissue. Overall, this research shows feasibility for a unique device which quantifies the strain on an orthopedic screw. Future research will involve reducing hysteresis by changing the mechanism of strain transduction in the screw, miniaturizing the luminescent strain gauge, monitoring bending as well as tension, using alternative luminescent spectral rulers based upon near infrared fluorescence or upconversion luminescence, and application to monitoring changes in pretension and load sharing during bone healing.

  14. Prostaglandin E2 Adds Bone to a Cancellous Bone Site with a Closed Growth Plate and Low Bone Turnover in Ovariectomized Rats

    NASA Technical Reports Server (NTRS)

    Ma, Y. F.; Ke, H. Z.; Jee, W. S. S.

    1994-01-01

    The objects of this study were to determine the responses of a cancellous bone site with a closed growth plate, (the distal tibial metaphysis (DTM), to ovariectomy (OVX) and OVX plus a prostaglandin E(2) treatment, and compare the site's response to previous findings reported for another site, the proximal tibial metaphysis (PTM). Thirty five 3-month old female Sprague-Dawley rats were divided into five groups; basal, sham OVX, and OVX+0, +1, or +6 mg PGE(2)/kg/d injected subcutaneously for 3 months and given double fluorescent labels before sacrifice. Cancellous bone histomorphometric analyses were performed on 20 micrometer thick undecalcified DTM sections. Similar to the PTM, the DTM showed age-related decreases in bone formation and increases in bone resorption, but it differed in that at 3 months POST OVX there was neither bone loss nor changes in formation endpoints. Giving 1 mg PGE(2)/kg/d to OVX rats prevented most age-related changes and maintained the bone formation histomorphometry near basal levels. Treating OVX rats with 6 mg PGE(2)/kd/d prevented age-related bone changes, added extra bone, and improved microanatomical structure by stimulating bone formation, without altering bone resportion. Futhermore, After PGE(2) admimnistration, the DTM, a cancellous bone site with a closed growth plate, increased bone formation more than did the cancellous bone in the PTM.

  15. Prostaglandin E2 Adds Bone to a Cancellous Bone Site with a Closed Growth Plate and Low Bone Turnover in Ovariectomized Rats

    NASA Technical Reports Server (NTRS)

    Ma, Y. F.; Ke, H. Z.; Jee, W. S. S.

    1994-01-01

    The objects of this study were to determine the responses of a cancellous bone site with a closed growth plate (the distal tibial metaphysis, DTM) to ovariectomy (OVX) and OVX plus a prostaglandin E2 (PGE2) treatment, and compare the site's response to previous findings reported for another site (the proximal tibial metaphysis, PTM). Thirty-five 3-month old female Sprague-Dawley rats were divided into five groups: basal, sham-OVX, and OVX+0, +1, or +6 mg PGE2/kg/d injected subcutaneously for 3 months and given double fluorescent labels before sacrifice. Cancellous bone histomorphometric analyses were performed on 20-micron-thick undecalcified DTM sections. Similar to the PTM, the DTM showed age-related decreases in bone formation and increases in bone resorption, but it differed in that at 3 months post-OVX; there was neither bone loss nor changes in formation endpoints. Giving 1 mg PGE2/kg/d to OVX rats prevented most age-related changes and maintained the bone formation histomorphometry near basal levels. Treating OVX rats with 6 mg PGE2/kg/d prevented age-related bone changes, added extra bone, and improved microanatomical structure by stimulating bone formation without altering bone resorption. Furthermore, after PGE2 administration, the DTM, a cancellous bone site with a closed growth plate, inereased bone formation more than did the cancellous bone in the PTM.

  16. Tightening force and torque of nonlocking screws in a reverse shoulder prosthesis.

    PubMed

    Terrier, A; Kochbeck, S H; Merlini, F; Gortchacow, M; Pioletti, D P; Farron, A

    2010-07-01

    Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  17. Surgical repair of propagating condylar fractures of the third metacarpal/metatarsal bones with cortical screws placed in lag fashion in 26 racehorses (2007-2015).

    PubMed

    Moulin, N; François, I; Coté, N; Alford, C; Cleary, O; Desjardins, M R

    2018-01-19

    Despite the recommendation of plate fixation for propagating condylar fractures of the third metacarpal (McIII) or third metatarsal bone (MtIII), lag screw fixation can be a viable surgical option. To evaluate short-term outcome and long-term racing performance of horses that underwent lag screw fixation of long condylar fractures of the McIII/MtIII. Retrospective case series. Medical records, post-surgical racing performance and outcome of 26 horses with propagating fractures of the medial and/or lateral condyle of McIII/MtIII were reviewed. Medical information included were age, breed, sex, physical examination at admission, circumstances of fracture, radiographic evaluation, anaesthesia and recovery records, surgical and post-operative management, as well as complications. Outcome included racing data and information from telephone interviews. Twenty-six horses (9 Standardbreds and 17 Thoroughbreds) were admitted with a long condylar fracture of the McIII/MtIII. Fore- and hindlimbs were equally represented with the left hindlimb being more frequently involved. Most of the fractures had a spiralling component (76%) and four (15%) were comminuted. Fifteen (58%) horses raced post-surgery including nine Standardbreds (100%) and six Thoroughbreds (35%). Twelve of them were placed in at least one race and 11 won at least once. One horse sustained a severe complication in recovery. No significant difference was observed in the racing performances before and after surgery. Follow-up method and duration were not standardised and there is a low number of cases with six surgeons. Long condylar fractures can be repaired using lag fashion technique combined with a half-limb or full-limb tight cast for recovery as a good surgical alternative. Similar results to plate fixation can be expected, with a return to racing of more than 50%, and the prognosis being even better for pacers. © 2018 EVJ Ltd.

  18. Which is the preferred revision technique for loosened iliac screw? A novel technique of boring cement injection from the outer cortical shell.

    PubMed

    Yu, Bin-Sheng; Yang, Zhan-Kun; Li, Ze-Min; Zeng, Li-Wen; Wang, Li-Bing; Lu, William Weijia

    2011-08-01

    An in vitro biomechanical cadaver study. To evaluate the pull-out strength after 5000 cyclic loading among 4 revision techniques for the loosened iliac screw using corticocancellous bone, longer screw, traditional cement augmentation, and boring cement augmentation. Iliac screw loosening is still a clinical problem for lumbo-iliac fusion. Although many revision techniques using corticocancellous bone, larger screw, and polymethylmethacrylate (PMMA) augmentation were applied in repairing pedicle screw loosening, their biomechanical effects on the loosened iliac screw remain undetermined. Eight fresh human cadaver pelvises with the bone mineral density values ranging from 0.83 to 0.97 g/cm were adopted in this study. After testing the primary screw of 7.5 mm diameter and 70 mm length, 4 revision techniques were sequentially established and tested on the same pelvis as follows: corticocancellous bone, longer screw with 100 mm length, traditional PMMA augmentation, and boring PMMA augmentation. The difference of the boring technique from traditional PMMA augmentation is that PMMA was injected into the screw tract through 3 boring holes of outer cortical shell without removing the screw. On an MTS machine, after 5000 cyclic compressive loading of -200∼-500 N to the screw head, axial maximum pull-out strengths of the 5 screws were measured and analyzed. The pull-out strengths of the primary screw and 4 revised screws with corticocancellous bone, longer screw and traditional and boring PMMA augmentation were 1167 N, 361 N, 854 N, 1954 N, and 1820 N, respectively. Although longer screw method obtained significantly higher pull-out strength than corticocancellous bone (P<0.05), the revised screws using these 2 techniques exhibited notably lower pull-out strength than the primary screw and 2 PMMA-augmented screws (P<0.05). Either traditional or boring PMMA screw showed obviously higher pull-out strength than the primary screw (P<0.05); however, no significant difference of

  19. The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.

    PubMed

    Deng, Ting; Jiang, Minghui; Lei, Qing; Cai, Lihong; Chen, Li

    2016-12-01

    Clinical trial for cervical screw insertion by using individualized 3-dimensional (3D) printing screw insertion templates device. The objective of this study is to evaluate the safety and accuracy of the individualized 3D printing screw insertion template in the cervical spine. Ten patients who underwent posterior cervical fusion surgery with cervical pedicle screws, laminar screws or lateral mass screws between December 2014 and December 2015 were involved in this study. The patients were examined by CT scan before operation. The individualized 3D printing templates were made with photosensitive resin by a 3D printing system to ensure the screw shafts entered the vertebral body without breaking the pedicle or lamina cortex. The templates were sterilized by a plasma sterilizer and used during the operation. The accuracy and the safety of the templates were evaluated by CT scans at the screw insertion levels after operation. The accuracy of this patient-specific template technique was demonstrated. Only one screw axis greatly deviated from the planned track and breached the cortex of the pedicle because the template was split by rough handling and then we inserted the screws under the fluoroscopy. The remaining screws were inserted in the track as preoperative design and the screw axis deviated by less than 2 mm. Vascular or neurologic complications or injuries did not happen. And no infection, broken nails, fracture of bone structure, or screw pullout occurred. This study verified the safety and the accuracy of the individualized 3D printing screw insertion templates in the cervical spine as a kind of intraoperative screw navigation. This individualized 3D printing screw insertion template was user-friendly, moderate cost, and enabled a radiation-free cervical screw insertion.

  20. Plate on plate osteosynthesis for the treatment of nonhealed periplate fractures.

    PubMed

    Arealis, Georgios; Nikolaou, Vassilios S; Lacon, Andrew; Ashwood, Neil; Hamlet, Mark

    2014-01-01

    Purpose. The purpose of this paper is to present our technique for the treatment of periplate fractures. Methods. From 2009 to 2012 we treated three patients. In all cases the existing plate was left and the new one placed over the existing. Locking screws were placed through both plates. The other screws in the new plate were used as best suited the fracture. Results. In all cases less than 6 months had passed between fractures. None of the original fractures had healed. Mean followup was 2 years. All fractures proceeded to union within 7 months. No complications were recorded. All the patients returned to their normal activities and were satisfied with the results of their treatment. Conclusion. Our plate on plate technique is effective for the treatment of periplate fractures. A solid fusion can be achieved at the new fracture site without disturbing the previous fixation.

  1. CT-guided percutaneous screw fixation plus cementoplasty in the treatment of painful bone metastases with fractures or a high risk of pathological fracture.

    PubMed

    Pusceddu, Claudio; Fancellu, Alessandro; Ballicu, Nicola; Fele, Rosa Maria; Sotgia, Barbara; Melis, Luca

    2017-04-01

    To evaluate the feasibility and effectiveness of computed tomography (CT)-guided percutaneous screw fixation plus cementoplasty (PSFPC), for either treatment of painful metastatic fractures or prevention of pathological fractures, in patients who are not candidates for surgical stabilization. Twenty-seven patients with 34 metastatic bone lesions underwent CT-guided PSFPC. Bone metastases were located in the vertebral column, femur, and pelvis. The primary end point was the evaluation of feasibility and complications of the procedure, in addition to the length of hospital stay. Pain severity was estimated before treatment and 1 and 6 months after the procedure using the visual analog scale (VAS). Functional outcome was assessed by improved patient walking ability. All sessions were completed and well tolerated. There were no complications related to either incorrect positioning of the screws during bone fixation or leakage of cement. All patients were able to walk within 6 h after the procedure and the average length of hospital stay was 2 days. The mean VAS score decreased from 7.1 (range, 4-9) before treatment to 1.6 (range, 0-6), 1 month after treatment, and to 1.4 (range 0-6) 6 months after treatment. Neither loosening of the screws nor additional bone fractures occurred during a median follow-up of 6 months. Our results suggest that PSFPC might be a safe and effective procedure that allows the stabilization of the fracture and the prevention of pathological fractures with significant pain relief and good recovery of walking ability, although further studies are required to confirm this preliminary experience.

  2. A novel combined method of osteosynthesis in treatment of tibial fractures: a comparative study on sheep with application of rod-through-plate fixator and bone plating.

    PubMed

    Tralman, G; Andrianov, V; Arend, A; Männik, P; Kibur, R T; Nõupuu, K; Uksov, D; Aunapuu, M

    2013-04-01

    The study compares the efficiency of a new bone fixator combining periostal and intramedullary osteosynthesis to bone plating in treatment of tibial fractures in sheep. Experimental osteotomies were performed in the middle third of the left tibia. Animals were divided into two groups: in one group (four animals) combined osteosynthesis (rod-through-plate fixator, RTP fixator) was applied, and in the other group (three animals) bone plating was used. The experiments lasted for 10 weeks during which fracture union was followed by radiography, and the healing process was studied by blood serum markers reflecting bone turnover and by histological and immunohistochemical investigations. In the RTP fixator group, animals started to load body weight on the operated limbs the next day after the surgery, while in the bone plating group, this happened only on the seventh day. In the RTP fixator group, consolidation of fractures was also faster, as demonstrated by radiographical, histological, and immunohistochemical investigations and in part by blood serum markers for bone formation. It can be concluded that application of RTP fixation is more efficient than plate fixation in the treatment of experimental osteotomies of long bones in sheep. © 2012 Blackwell Verlag GmbH.

  3. Increased wound complication with intramedullary screw fixation of clavicle fractures: Is it thermal necrosis?

    PubMed

    Domos, Peter; Tytherleigh-Strong, Graham; Van Rensburg, Lee

    2017-01-01

    Adult mid-shaft clavicle fractures are common injuries. For displaced fractures, open reduction with plate or intramedullary (IM) fixation is the widely used techniques. All methods have their own potential drawbacks, especially related to local soft tissue complications. There is little information about outcome and management of local wound complications after clavicle fracture fixations. Ninety-seven patients underwent open reduction and internal fixation, 17 were treated with IM screw fixation and 80 with plate fixation. Wound complication occurred in eight patients (8.2%) and rates differed significantly between IM and plate fixations (29.4% vs. 3.8%). Patients were assessed on average 58.3 months with visual analogue pain scores (VASs), Oxford Shoulder Score (OSS), and QuickDash (QD) score. Five patients had wound breakdown and three patients had wound erythema. In seven patients with stable fixation, it was possible to "dress and suppress" with average 3 weeks of oral antibiotics. One patient had unstable fixation and required longer antibiotic treatment with early screw removal. One patient developed a chronic discharging wound, requiring debridement and later plate removal. At final follow-up, all wounds remained healed, bony union was achieved in all. The average scores were: VAS 1, OSS 46, and QD 4.5. Good function with dry healed wound and united clavicle can be achieved. Further studies are required to investigate the difference in soft tissue complication rates, which may be due to the IM technique of retrograde drilling with a guide wire and due to aseptic thermal bone necrosis, rather than true infection.

  4. Theoretical prediction of pullout strengths for dental and orthopaedic screws with conical profile and buttress threads.

    PubMed

    Shih, Kao-Shang; Hou, Sheng-Mou; Lin, Shang-Chih

    2017-12-01

    The pullout strength of a screw is an indicator of how secure bone fragments are being held in place. Such bone-purchasing ability is sensitive to bone quality, thread design, and the pilot hole, and is often evaluated by experimental and numerical methods. Historically, there are some mathematical formulae to simulate the screw withdrawal from the synthetic bone. There are great variations in screw specifications. However, extensive investigation of the correlation between experimental and analytical results has not been reported in literature. Referring to the literature formulae, this study aims to evaluate the differences in the calculated pullout strengths. The pullout tests of the surgical screws are measured and the sawbone is used as the testing block. The absolute errors and correlation coefficients of the experimental and analytical results are calculated as the comparison baselines of the formulae. The absolute error of the dental, traumatic, and spinal groups are 21.7%, 95.5%, and 37.0%, respectively. For the screws with a conical profile and/or tiny threads, the calculated and measured results are not well correlated. The formulae are not accurate indicators of the pullout strengths of the screws where the design parameters are slightly varied. However, the experimental and numerical results are highly correlated for the cylindrical screws. The pullout strength of a conical screw is higher than that of its counterpart, but all formulae consistently predict the opposite results. In general, the bony purchase of the buttress threads is securer than that of the symmetric thread. An absolute error of up to 51.4% indicates the theoretical results cannot predict the actual value of the pullout strength. Only thread diameter, pitch, and depth are considered in the investigated formulae. The thread profile and shape should be formulated to modify the slippage mechanism at the bone-screw interfaces and simulate the strength change in the squeezed bones

  5. Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgery.

    PubMed

    Bredow, Jan; Boese, C K; Werner, C M L; Siewe, J; Löhrer, L; Zarghooni, K; Eysel, P; Scheyerer, M J

    2016-08-01

    Pedicle screw fixation is the standard technique for the stabilization of the spine, a clinically relevant complication of which is screw loosening. This retrospective study investigates whether preoperative CT scanning can offer a predictor of screw loosening. CT-scan attenuation in 365 patients was evaluated to determine the mean bone density of each vertebral body. Screw loosening or dislocation was determined in CT scans postoperatively using the standard radiological criteria. Forty-five of 365 patients (12.3 %; 24 male, 21 female) suffered postoperative screw loosening (62 of 2038 screws) over a mean follow-up time of 50.8 months. Revision surgeries were necessary in 23 patients (6.3 %). The correlation between decreasing mean CT attenuation in Hounsfield Units (HU) and increasing patient age was significant (p < 0.001). Mean bone density was 116.3 (SD 53.5) HU in cases with screw loosening and 132.7 (SD 41.3) HU in cases in which screws remained fixed. The difference was statistically significant (p = 0.003). The determination of bone density with preoperative CT scanning can predict the risk of screw loosening and inform the decision to use cement augmentation to reduce the incidence of screw loosening.

  6. Intraoral technique for locking reconstruction plate fixation using an implant handpiece with adapted drills.

    PubMed

    Haas, Orion Luiz; Scolari, Neimar; Meirelles, Lucas da Silva; Becker, Otávio Emmel; Melo, Marcelo Fernandes Santos; Viegas, Vinícius Nery; de Oliveira, Rogério Belle

    2016-09-01

    Locking reconstruction plates are used in the treatment of jaw trauma and diseases if there is a need for surgical resection and to prevent pathologic fracture after tumor excision. Fixation is typically performed using an extraoral approach. This article describes a technique for the intraoral fixation of locking reconstruction plates that uses prototyping to model the plate before the procedure as well as an implant handpiece with adapted drills for bone drilling and the insertion of screws into relatively inaccessible areas. Intraoral fixation not only prevents nerve damage and facial scarring but also minimizes the plate's risk of extraoral exposure and reduces surgical morbidity. © 2016 Wiley Periodicals, Inc. Head Neck 38: 1436-1439, 2016. © 2016 Wiley Periodicals, Inc.

  7. Automated Cell Detection and Morphometry on Growth Plate Images of Mouse Bone

    PubMed Central

    Ascenzi, Maria-Grazia; Du, Xia; Harding, James I; Beylerian, Emily N; de Silva, Brian M; Gross, Ben J; Kastein, Hannah K; Wang, Weiguang; Lyons, Karen M; Schaeffer, Hayden

    2014-01-01

    Microscopy imaging of mouse growth plates is extensively used in biology to understand the effect of specific molecules on various stages of normal bone development and on bone disease. Until now, such image analysis has been conducted by manual detection. In fact, when existing automated detection techniques were applied, morphological variations across the growth plate and heterogeneity of image background color, including the faint presence of cells (chondrocytes) located deeper in tissue away from the image’s plane of focus, and lack of cell-specific features, interfered with identification of cell. We propose the first method of automated detection and morphometry applicable to images of cells in the growth plate of long bone. Through ad hoc sequential application of the Retinex method, anisotropic diffusion and thresholding, our new cell detection algorithm (CDA) addresses these challenges on bright-field microscopy images of mouse growth plates. Five parameters, chosen by the user in respect of image characteristics, regulate our CDA. Our results demonstrate effectiveness of the proposed numerical method relative to manual methods. Our CDA confirms previously established results regarding chondrocytes’ number, area, orientation, height and shape of normal growth plates. Our CDA also confirms differences previously found between the genetic mutated mouse Smad1/5CKO and its control mouse on fluorescence images. The CDA aims to aid biomedical research by increasing efficiency and consistency of data collection regarding arrangement and characteristics of chondrocytes. Our results suggest that automated extraction of data from microscopy imaging of growth plates can assist in unlocking information on normal and pathological development, key to the underlying biological mechanisms of bone growth. PMID:25525552

  8. Percutaneous insertion of a proximal humeral locking plate: an anatomic study.

    PubMed

    Smith, Jason; Berry, Greg; Laflamme, Yves; Blain-Pare, Etienne; Reindl, Rudy; Harvey, Edward

    2007-02-01

    This cadaveric study sought to evaluate the feasibility of applying a locking proximal humerus plate with a novel minimally invasive technique. A unique pre-contoured locking plate was placed on cadaveric proximal humeri through a described minimally invasive approach. Proximity of the plate and screws to the axillary nerve and their respective surgical tracks were quantified. Safe screw hole placement with respect to the axillary nerve was determined. Risk of entrapment of the nerve beneath the plate was evaluated. Three of the holes near the middle of the locking plate consistently intersected the course of the axillary nerve and were unsafe for percutaneous placement of the screws. The axillary nerve could be palpated during the course of surgery and easily protected from injury. No entrapment of the axillary nerve occurred using this minimally invasive technique. The screw-in locking guide cannot be used with this technique as it caused tenting of the axillary nerve. Placement of a locking proximal humerus plate via a minimally invasive lateral trans-deltoid approach is safe if the locking screws are limited to superior and inferior holes. This can be done safely without entrapment of the axillary beneath the plate. Plate fixation of proximal humerus fractures may now be more desirable with the use of this approach.

  9. [Internal screwed plate for recent fractures of the humeral diaphysis in adults].

    PubMed

    Dayez, J

    1999-06-01

    Can medial plating of the humerus, through an antero lateral approach, diminish incidence of iatrogenic radial palsies? We carried out a prospective study of medial plating of humeral shaft fractures through an antero lateral approach between 1988 and 1997. 41 fractures were fixed, 36 were followed up for a mean period of 5.8 years. The indications were multiple injuries (10), displaced fractures (23), and failure of conservative treatment (3). Road traffic accidents and sports injuries were the cause in 68 per cent of cases. Two fractures were open and in 9 cases there was a radial palsy. Bone graft was never used. The approach to the medial aspect of the humerus an antero lateral incision was the essential feature of the technique. After a slightly curved incision on the antero lateral aspect of the arm, the space between biceps and brachialis anterior was bluntly dissected. The assistant holded the elbow flexed in order to relax the biceps and rotated il laterally to expose the medial aspect of the bone. Splitting brachialis fibres longitudinally exposed the fracture site. It was easy to check if the radial nerve was trapped and, if not, the nerve seen during the operation. Postoperatively patients were given a simple sling and mobilised freely, including rotation. We had no intra-operative complications, no infections, no fixation failure, no post operative radial palsies and no non-unions. Results were excellent in 89 per cent of cases (full recovery of pain free range of movement). Four patient had a restriction of elbow movements of 10 degrees but without any discomfort. The mean time to union was 80 days. All radial nerve palsies recovered between 24 hours and 1 year. The plate was removed in 11 cases. Iatrogenic complications of humeral plating have led to the increased popularity of intramedullary nailing. Even if secondary radial palsies and non-unions have decreased, union of the humeral shafts is often difficult. Placing the plate into the medial

  10. A biomechanical evaluation of a cannulated compressive screw for use in fractures of the scaphoid.

    PubMed

    Rankin, G; Kuschner, S H; Orlando, C; McKellop, H; Brien, W W; Sherman, R

    1991-11-01

    The compressive force generated by a 3.5 mm ASIF cannulated cancellous screw with a 5 mm head was compared with that generated by a standard 3.5 mm ASIF screw (6 mm head), a 2.7 mm ASIF screw (5 mm head), and a Herbert screw. The screws were evaluated in the laboratory with the use of a custom-designed load washer (transducer) to the maximum compressive force generated by each screw until failure, either by thread stripping or by head migration into the specimen. Testing was done on paired cadaver scaphoids. To minimize the variability that occurs with human bone, and because of the cost and difficulty of obtaining human tissue specimens, a study was also done on polyurethane foam simulated bones. The 3.5 cannulated screw generated greater compressive forces than the Herbert screw but less compression than the 2.7 mm and 3.5 mm ASIF cortical screws. The 3.5 mm cannulated screw offers more rigid internal fixation for scaphoid fractures than the Herbert screw and gives the added advantage of placement over a guide wire.

  11. The Impact of Nitinol Staples on the Compressive Forces, Contact Area, and Mechanical Properties in Comparison to a Claw Plate and Crossed Screws for the First Tarsometatarsal Arthrodesis.

    PubMed

    Aiyer, Amiethab; Russell, Nicholas A; Pelletier, Matthew H; Myerson, Mark; Walsh, William R

    2016-06-01

    Background The optimal fixation method for the first tarsometatarsal arthrodesis remains controversial. This study aimed to develop a reproducible first tarsometatarsal testing model to evaluate the biomechanical performance of different reconstruction techniques. Methods Crossed screws or a claw plate were compared with a single or double shape memory alloy staple configuration in 20 Sawbones models. Constructs were mechanically tested in 4-point bending to 1, 2, and 3 mm of plantar displacement. The joint contact force and area were measured at time zero, and following 1 and 2 mm of bending. Peak load, stiffness, and plantar gapping were determined. Results Both staple configurations induced a significantly greater contact force and area across the arthrodesis than the crossed screw and claw plate constructs at all measurements. The staple constructs completely recovered their plantar gapping following each test. The claw plate generated the least contact force and area at the joint interface and had significantly greater plantar gapping than all other constructs. The crossed screw constructs were significantly stiffer and had significantly less plantar gapping than the other constructs, but this gapping was not recoverable. Conclusions Crossed screw fixation provides a rigid arthrodesis with limited compression and contact footprint across the joint. Shape memory alloy staples afford dynamic fixation with sustained compression across the arthrodesis. A rigid polyurethane foam model provides an anatomically relevant comparison for evaluating the interface between different fixation techniques. Clinical Relevance The dynamic nature of shape memory alloy staples offers the potential to permit early weight bearing and could be a useful adjunctive device to impart compression across an arthrodesis of the first tarsometatarsal joint. Therapeutic, Level V: Bench testing. © 2015 The Author(s).

  12. Open Screw Placement in a 1.5 mm LCP Over a Fracture Gap Decreases Fatigue Life

    PubMed Central

    Alwen, Sarah G. J.; Kapatkin, Amy S.; Garcia, Tanya C.; Milgram, Joshua; Stover, Susan M.

    2018-01-01

    Objective To investigate the influence of plate and screw hole position on the stability of simulated radial fractures stabilized with a 1.5 mm condylar locking compression plate (LCP). Study Design In vitro mechanical testing of paired cadaveric limbs. Sample Population Paired radii (n = 7) stabilized with a 1.5 mm condylar LCP with an open screw hole positioned either proximal to (PG), or over (OG), a simulated small fracture gap. Methods Constructs were cycled in axial compression at a simulated trot load until failure or a maximum of 200,000 cycles. Specimens that sustained 200,000 cycles without failure were then loaded in axial compression in a single cycle to failure. Construct cyclic axial stiffness and gap strain, fatigue life, and residual strength were evaluated and compared between constructs using analysis of variance. Results Of pairs that had a failure during cyclic loading, OG constructs survived fewer cycles (54,700 ± 60,600) than PG (116,800 ± 49,300). OG constructs had significantly lower initial stiffness throughout cyclic loading and higher gap strain range within the first 1,000 cycles than PG constructs. Residual strength variables were not significantly different between constructs, however yield loads occurred at loads only marginally higher than approximated trot loads. Fatigue life decreased with increasing body weight. Conclusion Fracture fixation stability is compromised by an open screw hole directly over a fracture gap compared to the open screw hole being buttressed by bone in the model studied. The 1.5 mm condylar LCP may be insufficient stabilization in dogs with appropriate radial geometry but high body weights. PMID:29876361

  13. Probing and Tapping: Are We Inserting Pedicle Screws Correctly?

    PubMed

    Prasad, Vishal; Mesfin, Addisu; Lee, Robert; Reigrut, Julie; Schmidt, John

    2016-11-01

    Although there are a significant number of research publications on the topic of bone morphology and the strength of bone, the clinical significance of a failed pedicle screw is often revision surgery and the potential for further postoperative complications; especially in elderly patients with osteoporotic bone. The purpose of this report is to quantify the mechanical strength of the foam-screw interface by assessing probe/pilot hole diameter and tap sizes using statistically relevant sample sizes under highly controlled test conditions. The study consisted of two experiments and used up to three different densities of reference-grade polyurethane foam (ASTM 1839), including 0.16, 0.24, and 0.32 g/cm 3 . All screws and rods were provided by K2M Inc. and screws were inserted to a depth of 25 mm. A series of pilot holes, 1.5, 2.2, 2.7, 3.2, 3.7, 4.2, 5.0, and 6.0 mm in diameter were drilled through the entire depth of the material. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 720). A 3.0-mm pilot hole was drilled and tapped with: no tap, 3.5-, 4.5-, 5.5-, and 6.5-mm taps. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 300). The size of the probe/pilot hole had a nonlinear, parabolic effect on pullout strength. This shape suggests an optimum-sized probe hole for a given size pedicle screw. Too large or too small of a probe hole causes a rapid falloff in pullout strength. The tap data demonstrated that not tapping and undertapping by two or three sizes did not significantly alter the pullout strength of the screws. The data showed an exponential falloff of pullout strength when as tap size increased to the diameter of the screw. In the current study, the data show that an ideal pilot hole size half the diameter of the screw is a starting point. Also, that if tapping was necessary, to use a tap two sizes smaller than the screw being implanted. A similar optimum pilot hole or tap size may be

  14. [Clinical application of atlantoaxial pedicle screw internal fixation for treatment of atlantoaxial dislocation].

    PubMed

    Yang, Yong-Jun; Zhang, En-Zhong; Tan, Yuan-Chao; Zhou, Ji-Ping; Yao, Shu-Qiang; Jiang, Chuan-Jie; Cong, Pei-Yan

    2009-11-01

    To investigate the clinical effect of atlantoaxial pedicle screw internal fixation for treatment of atlantoaxial dislocation. Sixteen patients with atlantoaxial dislocation were treated from Dec. 2005 to June 2007, included 10 males and 6 females, aged from 38 to 45 years old (means 40.5 years). Among them 12 patients combined with nerve injury, according to ASIA grade: there were 3 cases in grade B, 5 cases in grade C, 4 cases in grade D. All patients received preoperative CT, radiograph and skull traction. Intraoperative posterior approach general spine pedicle screw-rod orthopaedics fixation system used and iliac bone block were implanted in space of posterior atlantal arch and axial vertebral plate. The outcome and complications were observed in the near future. There was no vascular or neural injury found. The patients were followed up for 12 to 24 months (means 18 months). All head pain, acid storm symptoms were improved after operation. According to the Odom's clinical efficacy evaluation standard, 12 cases were excellent, 4 were good. Eleven cases of 12 with nerve injury recovered significantly. By ASIA classification: 1 cases was in grade B, 2 cases were in grade C, 5 cases were in grade D, 4 cases were in grade E. No looseness or breakage of screw occurred. Bony fusion was achieved in all cases. Posterior approach atlantoaxial pedicle screw internal fixation have the advantages of direct screw placement, short-segment fusion, intraoperative reduction, fixation reliable, high fusion rate, and it can restablish the upper cervical vertebrae stability and help to recover the spinal cord and nerve function.

  15. Biomechanical and biological aspects of defect treatment in fractures using helical plates.

    PubMed

    Perren, S M; Regazzoni, P; Fernandez, A A D

    2014-01-01

    conventional plate is the extent of surgical trauma at the critical site of healing. - Shingling and/or applying an autologous cancellous bone graft: This procedure provides initially no relevant load sharing but will do so after a couple of weeks. The mechanical coupling of the comparably soft graft and the main fracture fragments presents little problems. Applying a cortical bone graft: Such a graft does provide initial only small load sharing and does a less good job inducing callus than a cancellous graft. Furthermore, the coupling by callus between a somewhat rigid bone graft and the mobile main fracture fragments requires a solid maintained contact. If the cortical graft is fixed using implants with small contact area to the graft such as screws or cerclage loops, the local stress may be critical and the graft may break. When the cortical graft is fixed with cerclage wires the procedure must take into account the limited strength of the individual cerclage. Therefore multiple and well-spaced cerclages are required and may lead to success especially if an intramedullary component of the implant contributes to protection (6). The degree of unloading depends apparently on the stiffness of the material of the protecting splint. Though, more important is the effect of the dimensions of the splint. While titanium as a material is about 50% less stiff than steel, the thickness of the implant changes the stiffness with the third power. That is doubling the thickness results in eightfold increased stiffness. When considering the unloading by application of a second plate the leverage of the second plate plays an important role. The larger the distance between the axis of bending and the second implant the larger the protecting effect. The helical plate (2, 3, 7) as introduced by A.A.D. Fernandez offers biological and mechanical advantages. It can be applied without touching the fracture site maintaining the critical biology intact and provides mechanically efficient unloading

  16. Structure Model Index Does Not Measure Rods and Plates in Trabecular Bone

    PubMed Central

    Salmon, Phil L.; Ohlsson, Claes; Shefelbine, Sandra J.; Doube, Michael

    2015-01-01

    Structure model index (SMI) is widely used to measure rods and plates in trabecular bone. It exploits the change in surface curvature that occurs as a structure varies from spherical (SMI = 4), to cylindrical (SMI = 3) to planar (SMI = 0). The most important assumption underlying SMI is that the entire bone surface is convex and that the curvature differential is positive at all points on the surface. The intricate connections within the trabecular continuum suggest that a high proportion of the surface could be concave, violating the assumption of convexity and producing regions of negative differential. We implemented SMI in the BoneJ plugin and included the ability to measure the amounts of surface that increased or decreased in area after surface mesh dilation, and the ability to visualize concave and convex regions. We measured SMI and its positive (SMI+) and negative (SMI−) components, bone volume fraction (BV/TV), the fraction of the surface that is concave (CF), and mean ellipsoid factor (EF) in trabecular bone using 38 X-ray microtomography (XMT) images from a rat ovariectomy model of sex steroid rescue of bone loss, and 169 XMT images from a broad selection of 87 species’ femora (mammals, birds, and a crocodile). We simulated bone resorption by eroding an image of elephant trabeculae and recording SMI and BV/TV at each erosion step. Up to 70%, and rarely <20%, of the trabecular surface is concave (CF 0.155–0.700). SMI is unavoidably influenced by aberrations induced by SMI−, which is strongly correlated with BV/TV and CF. The plate-to-rod transition in bone loss is an erroneous observation resulting from the close and artifactual relationship between SMI and BV/TV. SMI cannot discern between the distinctive trabecular geometries typical of mammalian and avian bone, whereas EF clearly detects birds’ more plate-like trabeculae. EF is free from confounding relationships with BV/TV and CF. SMI results reported in the literature should be

  17. A Biomechanical Comparison of Three 1.5-mm Plate and Screw Configurations and a Single 2.0-mm Plate for Internal Fixation of a Mandibular Condylar Fracture

    PubMed Central

    Aquilina, Peter; Parr, William C.H.; Chamoli, Uphar; Wroe, Stephen; Clausen, Philip

    2014-01-01

    The most stable pattern of internal fixation for mandibular condyle fractures is an area of ongoing discussion. This study investigates the stability of three patterns of plate fixation using readily available, commercially pure titanium implants. Finite element models of a simulated mandibular condyle fracture were constructed. The completed models were heterogeneous in bone material properties, contained approximately 1.2 million elements and incorporated simulated jaw adducting musculature. Models were run assuming linear elasticity and isotropic material properties for bone. No human subjects were involved in this investigation. The stability of the simulated condylar fracture reduced with the different implant configurations, and the von Mises stresses of a 1.5-mm X-shaped plate, a 1.5-mm rectangular plate, and a 1.5-mm square plate (all Synthes (Synthes GmbH, Zuchwil, Switzerland) were compared. The 1.5-mm X plate was the most stable of the three 1.5-mm profile plate configurations examined and had comparable mechanical performance to a single 2.0-mm straight four-hole plate. This study does not support the use of rectangular or square plate patterns in the open reduction and internal fixation of mandibular condyle fractures. It does provide some support for the use of a 1.5-mm X plate to reduce condylar fractures in selected clinical cases. PMID:25136411

  18. Anterior debridement and fusion followed by posterior pedicle screw fixation in pyogenic spondylodiscitis: autologous iliac bone strut versus cage.

    PubMed

    Pee, Yong Hun; Park, Jong Dae; Choi, Young-Geun; Lee, Sang-Ho

    2008-05-01

    An anterior approach for debridement and fusion with autologous bone graft has been recommended as the gold standard for surgical treatment of pyogenic spondylodiscitis. The use of anterior foreign body implants at the site of active infection is still a challenging procedure for spine surgeons. Several authors have recently introduced anterior grafting with titanium mesh cages instead of autologous bone strut in the treatment of spondylodiscitis. The authors present their experience of anterior fusion with 3 types of cages followed by posterior pedicle screw fixation. They also compare their results with the use of autologous iliac bone strut. The authors retrospectively reviewed the cases of 60 patients with pyogenic spondylodiscitis treated by anterior debridement between January 2003 and April 2005. Fusion using either cages or iliac bone struts was performed during the same course of anesthesia followed by posterior fixation. Twenty-three patients underwent fusion with autologous iliac bone strut, and 37 patients underwent fusion with 1 of the 3 types of cages. The infections resolved in all patients, as noted by normalization of their erythrocyte sedimentation rates and C-reactive protein levels. Patients in both groups were evaluated in terms of their preoperative and postoperative clinical and imaging findings. Single-stage anterior debridement and cage fusion followed by posterior pedicle screw fixation can be effective in the treatment of pyogenic spondylodiscitis. There was no difference in clinical and imaging outcomes between the strut group and cage group except for the subsidence rate. The subsidence rate was higher in the strut group than in the cage group. The duration until subsidence was also shorter in the strut group than in the cage group.

  19. Adapter plate assembly for adjustable mounting of objects

    DOEpatents

    Blackburn, R.S.

    1986-05-02

    An adapter plate and two locking discs are together affixed to an optic table with machine screws or bolts threaded into a fixed array of internally threaded holes provided in the table surface. The adapter plate preferably has two, and preferably parallel, elongated locating slots each freely receiving a portion of one of the locking discs for secure affixation of the adapter plate to the optic table. A plurality of threaded apertures provided in the adapter plate are available to attach optical mounts or other devices onto the adapter plate in an orientation not limited by the disposition of the array of threaded holes in the table surface. An axially aligned but radially offset hole through each locking disc receives a screw that tightens onto the table, such that prior to tightening of the screw the locking disc may rotate and translate within each locating slot of the adapter plate for maximum flexibility of the orientation thereof.

  20. Adapter plate assembly for adjustable mounting of objects

    DOEpatents

    Blackburn, Robert S.

    1987-01-01

    An adapter plate and two locking discs are together affixed to an optic table with machine screws or bolts threaded into a fixed array of internally threaded holes provided in the table surface. The adapter plate preferably has two, and preferably parallel, elongated locating slots each freely receiving a portion of one of the locking discs for secure affixation of the adapter plate to the optic table. A plurality of threaded apertures provided in the adapter plate are available to attach optical mounts or other devices onto the adapter plate in an orientation not limited by the disposition of the array of threaded holes in the table surface. An axially aligned but radially offset hole through each locking disc receives a screw that tightens onto the table, such that prior to tightening of the screw the locking disc may rotate and translate within each locating slot of the adapter plate for maximum flexibility of the orientation thereof.

  1. Treatment of unicameral calcaneal bone cysts in children: review of literature and results using a cannulated screw for continuous decompression of the cyst.

    PubMed

    Saraph, Vinay; Zwick, Ernst-Bernhard; Maizen, Claudia; Schneider, Frank; Linhart, Wolfgang E

    2004-01-01

    Nine unicameral bone cysts of the calcaneus in children were managed surgically using the technique of continuous decompression with titanium cannulated cancellous screws. The average age of the patients at surgery was 12.8 years. At follow-up a minimum of 2 years after surgery, eight cysts showed complete healing; one patient showed healing with residuals. Irritation at the screw insertion site necessitated early removal of the screw in one patient; implant-related problems were not observed in the other patients. Patients were allowed to bear weight after surgery. Implant extraction was performed after full consolidation of the cyst and was uneventful in all patients. A review of the literature and the different treatment modalities used for managing calcaneal cysts is also presented.

  2. Implant Augmentation: Adding Bone Cement to Improve the Treatment of Osteoporotic Distal Femur Fractures

    PubMed Central

    Wähnert, Dirk; Hofmann-Fliri, Ladina; Richards, R. Geoff; Gueorguiev, Boyko; Raschke, Michael J.; Windolf, Markus

    2014-01-01

    Abstract The increasing problems in the field of osteoporotic fracture fixation results in specialized implants as well as new operation methods, for example, implant augmentation with bone cement. The aim of this study was to determine the biomechanical impact of augmentation in the treatment of osteoporotic distal femur fractures. Seven pairs of osteoporotic fresh frozen distal femora were randomly assigned to either an augmented or nonaugmented group. In both groups, an Orthopaedic Trauma Association 33 A3 fractures was fixed using the locking compression plate distal femur and cannulated and perforated screws. In the augmented group, additionally, 1 mL of polymethylmethacrylate cement was injected through the screw. Prior to mechanical testing, bone mineral density (BMD) and local bone strength were determined. Mechanical testing was performed by cyclic axial loading (100 N to 750 N + 0.05N/cycle) using a servo-hydraulic testing machine. As a result, the BMD as well as the axial stiffness did not significantly differ between the groups. The number of cycles to failure was significantly higher in the augmented group with the BMD as a significant covariate. In conclusion, cement augmentation can significantly improve implant anchorage in plating of osteoporotic distal femur fractures. PMID:25415673

  3. Use of 3D Printed Bone Plate in Novel Technique to Surgically Correct Hallux Valgus Deformities

    PubMed Central

    Smith, Kathryn E.; Dupont, Kenneth M.; Safranski, David L.; Blair, Jeremy; Buratti, Dawn; Zeetser, Vladimir; Callahan, Ryan; Lin, Jason; Gall, Ken

    2016-01-01

    Three-dimensional (3-D) printing offers many potential advantages in designing and manufacturing plating systems for foot and ankle procedures that involve small, geometrically complex bony anatomy. Here, we describe the design and clinical use of a Ti-6Al-4V ELI bone plate (FastForward™ Bone Tether Plate, MedShape, Inc., Atlanta, GA) manufactured through 3-D printing processes. The plate protects the second metatarsal when tethering suture tape between the first and second metatarsals and is a part of a new procedure that corrects hallux valgus (bunion) deformities without relying on doing an osteotomy or fusion procedure. The surgical technique and two clinical cases describing the use of this procedure with the 3-D printed bone plate are presented within. PMID:28337049

  4. Influence of screw length and diameter on tibial strain energy density distribution after anterior cruciate ligament reconstruction

    NASA Astrophysics Data System (ADS)

    Yao, Jie; Kuang, Guan-Ming; Wong, Duo Wai-Chi; Niu, Wen-Xin; Zhang, Ming; Fan, Yu-Bo

    2014-04-01

    Postoperative tunnel enlargement has been frequently reported after anterior cruciate ligament (ACL) reconstruction. Interference screw, as a surgical implant in ACL reconstruction, may influence natural loading transmission and contribute to tunnel enlargement. The aims of this study are (1) to quantify the alteration of strain energy den sity (SED) distribution after the anatomic single-bundle ACL reconstruction; and (2) to characterize the influence of screw length and diameter on the degree of the SED alteration. A validated finite element model of human knee joint was used. The screw length ranging from 20 to 30mm with screw diameter ranging from 7 to 9 mm were investigated. In the post-operative knee, the SED increased steeply at the extra-articular tunnel aperture under compressive and complex loadings, whereas the SED decreased beneath the screw shaft and nearby the intra-articular tunnel aperture. Increasing the screw length could lower the SED deprivation in the proximal part of the bone tunnel; whereas increasing either screw length or diameter could aggravate the SED deprivation in the distal part of the bone tunnel. Decreasing the elastic modulus of the screw could lower the bone SED deprivation around the screw. In consideration of both graft stability and SED alteration, a biodegradable interference screw with a long length is recommended, which could provide a beneficial mechanical environment at the distal part of the tunnel, and meanwhile decrease the bone-graft motion and synovial fluid propagation at the proximal part of the tunnel. These findings together with the clinical and histological factors could help to improve surgical outcome, and serve as a preliminary knowledge for the following study of biodegradable interference screw. [Figure not available: see fulltext.

  5. Comparison of Two Xenograft Materials Used in Sinus Lift Procedures: Material Characterization and In Vivo Behavior

    PubMed Central

    Ramírez Fernández, María Piedad; Mazón, Patricia; Gehrke, Sergio A.; Calvo-Guirado, Jose Luis; De Aza, Piedad N.

    2017-01-01

    Detailed information about graft material characteristic is crucial to evaluate their clinical outcomes. The present study evaluates the physico-chemical characteristics of two xenografts manufactured on an industrial scale deproteinized at different temperatures (non-sintered and sintered) in accordance with a protocol previously used in sinus lift procedures. It compares how the physico-chemical properties influence the material’s performance in vivo by a histomorphometric study in retrieved bone biopsies following maxillary sinus augmentation in 10 clinical cases. An X-ray diffraction analysis revealed the typical structure of hydroxyapatite (HA) for both materials. Both xenografts were porous and exhibited intraparticle pores. Strong differences were observed in terms of porosity, crystallinity, and calcium/phosphate. Histomorphometric measurements on the bone biopsies showed statistically significant differences. The physic-chemical assessment of both xenografts, made in accordance with the protocol developed on an industrial scale, confirmed that these products present excellent biocompatibilitity, with similar characteristics to natural bone. The sintered HA xenografts exhibited greater osteoconductivity, but were not completely resorbable (30.80 ± 0.88% residual material). The non-sintered HA xenografts induced about 25.92 ± 1.61% of new bone and a high level of degradation after six months of implantation. Differences in the physico-chemical characteristics found between the two HA xenografts determined a different behavior for this material. PMID:28772984

  6. Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience.

    PubMed

    Yu, Ke-He; Hong, Jian-Jun; Guo, Xiao-Shan; Zhou, Dong-Sheng

    2015-09-22

    The objective of this study is to compare the biomechanical properties and clinical outcomes of Tile B1 type pubic symphysis diastasis (PSD) treated by percutaneous cannulated screw fixation (PCSF) and reconstruction plate screw fixation (RPSF). Finite element analysis (FEA) was used to compare the biomechanical properties between PCSF and RPSF. CT scan data of one PSD patient were used for three-dimensional reconstructions. After a validated pelvic finite element model was established, both PCSF and RPSF were simulated, and a vertical downward load of 600 N was loaded. The distance of pubic symphysis and stress were tested. Then, 51 Tile type B1 PSD patients (24 in the PCSF group; 27 in the RPSF group) were reviewed. Intra-operative blood loss, operative time, and the length of the skin scar were recorded. The distance of pubic symphysis was measured, and complications of infection, implant failure, and revision surgery were recorded. The Majeed scoring system was also evaluated. The maximum displacement of the pubic symphysis was 0.408 and 0.643 mm in the RPSF and PCSF models, respectively. The maximum stress of the plate in RPSF was 1846 MPa and that of the cannulated screw in PCSF was 30.92 MPa. All 51 patients received follow-up at least 18 months post-surgery (range 18-54 months). Intra-operative blood loss, operative time, and the length of the skin scar in the PCSF group were significantly different than those in the RPSF group. No significant differences were found in wound infection, implant failure, rate of revision surgery, distance of pubic symphysis, and Majeed score. PCSF can provide comparable biomechanical properties to RPSF in the treatment of Tile B1 type PSD. Meanwhile, PCSF and RPSF have similar clinical and radiographic outcomes. Furthermore, PCSF also has the advantages of being minimally invasive, has less blood loss, and has shorter operative time and skin scar.

  7. Pedicle screws with a thin hydroxyapatite coating for improving fixation at the bone-implant interface in the osteoporotic spine: experimental study in a porcine model.

    PubMed

    Ohe, Makoto; Moridaira, Hiroshi; Inami, Satoshi; Takeuchi, Daisaku; Nohara, Yutaka; Taneichi, Hiroshi

    2018-03-30

    OBJECTIVE Instrumentation failure caused by the loosening of pedicle screws (PSs) in patients with osteoporosis is a serious problem after spinal surgery. The addition of a thin hydroxyapatite (HA) surface coating applied by using a sputtering process was reported recently to be a promising method for providing bone conduction around an implant without a significant risk of coating-layer breakage. In this study, the authors evaluated the biomechanical and histological features of the bone-implant interface (BII) of PSs with a thin HA coating in an in vivo porcine osteoporotic spine model. METHODS Three types of PSs (untreated/standard [STPS], sandblasted [BLPS], and HA-coated [HAPS] PSs) were implanted into the thoracic and lumbar spine (T9-L6) of 8 mature Clawn miniature pigs (6 ovariectomized [osteoporosis group] and 2 sham-operated [control group] pigs). The spines were harvested from the osteoporosis group at 0, 2, 4, 8, 12, or 24 weeks after PS placement and from the control group at 0 or 24 weeks. Their bone mineral density (BMD) was measured by peripheral quantitative CT. Histological evaluation of the BIIs was conducted by performing bone volume/tissue volume and bone surface/implant surface measurements. The strength of the BII was evaluated with extraction torque testing. RESULTS The BMD decreased significantly in the osteoporosis group (p < 0.01). HAPSs exhibited the greatest mean extraction peak torque at 8 weeks, and HAPSs and BLPSs exhibited significantly greater mean torque than the STPSs at 12 weeks (p < 0.05). The bone surface/implant surface ratio was significantly higher for HAPSs than for STPSs after 2 weeks (p < 0.05), and bonding between bone and the implant surface was maintained until 24 weeks with no detachment of the coating layer. In contrast, the bone volume/tissue volume ratio was significantly higher for HAPSs than for BLPSs or STPSs only at 4 weeks. CONCLUSIONS Using PSs with a thin HA coating applied using a sputtering process

  8. Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

    PubMed

    Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M

    2007-12-01

    Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.

  9. Clinical application of locked plating system in children. An orthopaedic view

    PubMed Central

    Zafra-Jimenez, Jose Alberto; Rodriguez Martin, Juan

    2010-01-01

    In recent years, the locked plating system has gained favour in the treatment of certain fractures in adults; however, there is not much information regarding its use in children. We think there could be some advantages and applications such as: an alternative to external fixation, the bridge plating technique, unicortical screws, removal of hardware, metadiaphyseal fractures, periarticular fractures, poor quality bone, and allograft fixation. However, there are some disadvantages to keep in mind and the final decision for using it should be based on the osteosynthesis method principle the surgeon would like to apply. In this review article we discuss the up-to-date possible clinical applications and issues of this system. PMID:20162415

  10. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.

    PubMed

    Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo

    2018-01-01

    OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p < 0.05 and p > 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT

  11. Comparison of 2 kinds of pedicle screws in primary spinal instrumentation: biomechanical and interfacial evaluations in sheep vertebrae in vitro.

    PubMed

    Liu, Da; Zhang, Yi; Lei, Wei; Wang, Cai-ru; Xie, Qing-yun; Liao, Dong-fa; Jiang, Kai; Zhou, Jin-song; Zhang, Bo; Pan, Xian-ming

    2014-04-01

    Expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) were inserted in sheep vertebrae in vitro and were evaluated by performing biomechanical tests, radiographic examinations and histological observations. The objective of the study was to compare the biomechanical and interfacial performances of EPS and PMMA-PS in sheep lumbar vertebrae in vitro. It is a great challenge for orthopedic surgeons performing transpedicular fixation in the osteoporotic spine. It was reported that either the EPS or PMMA-PS could increase the screw stability. However, there are no studies comparing the 2 kinds of screws especially in primary spinal instrumentation. A total of 60 sheep lumbar vertebrae were randomly divided into 3 groups. A pilot hole was made in advance in all samples using the same method. Thereafter, the conventional pedicle screw (CPS) was inserted directly into the pilot hole in the CPS group; the hole in PMMA-PS group was first filled with polymethylmethacrylate (PMMA; 1.0 mL) and then inserted with CPS; and the EPS was inserted directly into the vertebrae in EPS group. After a period of 24 hours, biomechanical tests were performed to evaluate screw stability, and x-ray examination, micro-computerized tomography analysis, and histologic observation were performed to evaluate the interface between screw and bone. Compared with the stability of CPS, those of EPS and PMMA-PS were significantly enhanced. However, no significant differences were detected between the stabilities of EPS and PMMA-PS. The PMMA surrounding the screw blocked direct contact between bone and screw and formed a "screw-PMMA-bone" interface in the PMMA-PS group. There was a "screw-bone" interface in both CPS and EPS groups. Nevertheless, the expanded anterior part of EPS formed a claw-like structure pressing the surrounding bone trabeculae, which made the local bone tissue more compacted and denser than that in the CPS group. EPS can enhance the screw stability

  12. [Surgical strategy for upper cervical vertebrae instability through the anterior approach].

    PubMed

    Huang, Wei-bing; Cai, Xian-hua; Chen, Zhuang-hong; Huang, Ji-feng; Liu, Xi-ming; Wei, Shi-jun

    2013-07-01

    To explore the choice and effect of internal fixation in treating upper cervical vertebrae instability through anterior approach. From March 2000 to September 2010,83 patients with upper cervical vertebrae instability were treated with internal fixation through anterior approach. There were 59 males and 24 females with a mean age of 42 years old (ranged, 20 to 68). Among these patients, 36 patients were treated with odontoid screw fixation, 16 patients with C1,2 transarticular screw fixation, 23 patients with C2,3 steel plate fixation, 5 patients with odontoid screw and transarticular screw fixation,2 patients with odontoid screw and C2.3 steel plate fixation, 1 patient with C1,2 transarticular screw and C2,3 steel plate fixation. One patient with completely cervical vertebrae cord injury died of pulmonary infection after C1,2 transarticular screw fixation. Other patients were followed up from 8 to 36 months with an average of 15 months. Upper cervical vertebrae stability were restored without vertebral artery and spinal cord injury. Thirty-six patients were treated with odontoid screw fixation and 5 patients were treated with screw combined with transarticular screw fixation obtained bone union in the dentations without bone graft. Among the 16 patients treated with C1,2 transarticular screw fixation, 13 patients obtained bone union after bone graft; 1 patient died of pulmonary infection after surgery; 1 patient with comminuted odontoid fracture of type II C and atlantoaxial anterior dislocation did not obtain bone union after bone graft,but the fibrous healing was strong enough to maintain the atlantoaixal joint stability; 1 patient with obsolete atlantoaxial anterior dislocation were re-treated with Brooks stainless steel wire fixation and bone graft through posterior approach, and finally obtained bone union. It could obtain satisfactory effects depending on the difference of cervical vertebrae instability to choose the correctly surgical method.

  13. Mechanical stability of a novel screw design after repeated insertion: can the double-thread screw serve as a back up?

    PubMed

    Wiendieck, Kurt; Müller, Helge; Buchfelder, Michael; Sommer, Björn

    2018-06-01

    We investigated mechanical pull-out behavior and tightening torque of a novel dual-core pedicle "6T screw" (6T). The aim of this study was to test if these changes in screw geometry are increasing the strength of the pedicle screw fixation after repeated insertion. Three different types of pedicle screws were inserted in rigid foam blocks. Tightening torque and pull-out strength were measured during two repetitive insertions of a standard 6.5×45-mm conical screw. The third insertion into the pilot hole was performed using either standard 6.5×45-mm or 7.2×45-mm conical screws or the novel 6.5×45-mm (6T) screw. Additionally, we performed a surface analysis to investigate the bone/screw interface. The maximal tightening torque at the third insertion of the novel 6T screw was 194% higher compared to the standard 6.5×45-mm conical screw and 135% higher compared to the standard 7.2×45-mm conical screw. The pull-out strength of the 6T screw showed no significant changes, and surface analysis revealed a compression of the screw-foam interface due to the different internal diameters. The modified geometrical design of the 6T screw seems to have no statistically significant effect on the pull-out strength, although it achieved a higher tightening torque. This might be due to the different pitch angle cutting a new thread into the material and also to the enlarged inner diameter.

  14. Screw fixation of the syndesmosis: a cadaver model comparing stainless steel and titanium screws and three and four cortical fixation.

    PubMed

    Beumer, Annechien; Campo, Martin M; Niesing, Ruud; Day, Judd; Kleinrensink, Gert-Jan; Swierstra, Bart A

    2005-01-01

    We assessed syndesmotic set screw strength and fixation capacity during cyclical testing in a cadaver model simulating protected weight bearing. Sixteen fresh frozen legs with artificial syndesmotic injuries and a syndesmotic set screw made of stainless steel or titanium, inserted through three or four cortices, were axially loaded with 800 N for 225,000 cycles in a materials testing machine. The 225,000 cycles equals the number of paces taken by a person walking in a below knee plaster during 9 weeks. Syndesmotic fixation failure was defined as: bone fracture, screw fatigue failure, screw pullout, and/or excessive syndesmotic widening. None of the 14 out of 16 successfully tested legs or screws failed. No difference was found in fixation of the syndesmosis when stainless steel screws were compared to titanium screws through three or four cortices. Mean lateral displacement found after testing was 1.05 mm (S.D. = 0.42). This increase in tibiofibular width exceeds values described in literature for the intact syndesmosis loaded with body weight. Based on this laboratory study it is concluded that the syndesmotic set screw cannot prevent excessive syndesmotic widening when loaded with a load comparable with body weight. Therefore, we advise that patients with a syndesmotic set screw in situ should not bear weight.

  15. Influence of Hydroxyapatite Stick on Pedicle Screw Fixation in Degenerative Lumbar Spine: Biomechanical and Radiologic Study.

    PubMed

    Shin, Sung Joon; Lee, Ji-Ho; Lee, Jae Hyup

    2017-07-01

    A prospective, within-patient, left-right comparative study. To evaluate the efficacy of hydroxyapatite (HA) stick augmentation method by comparing the insertional torque of the pedicle screw in osteoporotic and nonosteoporotic patients. Unsatisfactory clinical outcomes after spine surgery in osteoporotic patients are related to pedicle screw loosening or pull-outs. HA, as a bone graft extender, has a possibility to enhance the fixation strength at the bone-screw interface. From November 2009 to December 2010, among patients who required bilateral pedicle screw fixation for lumbar spine surgery, 22 patients were enrolled, who recieved unilateral HA stick augmentation and completed intraoperative insertional torque measurement of each pedicle screws. On the basis of preoperative evaluation of bone mineral density, patients with osteoporosis had 2 HA sticks inserted unilaterally, and 1 stick for patients without osteoporosis. Pedicle screw loosening and pull-outs were assessed using 12-month postoperative CT scans and follow-up radiographs. Clinical evaluation was done preoperatively and at 1 year postoperatively, based on Visual Analog Scale score, Oswestry Disability Index, and Short Form-36 Health Survey. Regardless of bone mineral density, the average torque value of all pedicle screws with HA stick insertion (HA stick inserted group) was significantly higher than that of all pedicle screws without HA insertion (control group) (P<0.0001). Same results were seen in the HA stick inserted subgroups and the control subgroups within both of the osteoporosis group (P=0.009) and the nonosteoporosis group (P=0.0004). There was no statistically significant difference of the rate of pedicle screw loosening in between the HA stick inserted group and the control group. Clinical evaluation also showed no statistically significant difference in between patients with loosening and those without. The enhancement of initial pedicle screw fixation strength in osteoporotic patients

  16. The electron microscope appearance of the subchondral bone plate in the human femoral head in osteoarthritis and osteoporosis

    PubMed Central

    LI, BAOHUA; MARSHALL, DEBORAH; ROE, MARTIN; ASPDEN, RICHARD M.

    1999-01-01

    The subchondral bone plate supports the articular cartilage in diarthrodial joints. It has a significant mechanical function in transmitting loads from the cartilage into the underlying cancellous bone and has been implicated in the destruction of cartilage in osteoarthritis (OA) and its sparing in osteoporosis (OP), but little is known of its composition, structure or material properties. This study investigated the microscopic appearance and mineral composition of the subchondral bone plate in femoral heads from patients with OA or OP to determine how these correspond to changes in composition and stiffness found in other studies. Freeze-fractured full-depth samples of the subchondral bone plate from the femoral heads of patients with osteoarthritis, osteoporosis or a matched control group were examined using back scattered and secondary emission scanning electron microscopy. Other samples were embedded and polished and examined using back-scattered electron microscopy and electron probe microanalysis. The appearances of the samples from the normal and osteoporotic patients were very similar, with the subchondral bone plate overlayed by a layer of calcified cartilage. Osteoporotic samples presented a more uniform fracture surface and the relative thicknesses of the layers appeared to be different. In contrast, the OA bone plate appeared to be porous and have a much more textured surface. There were occasional sites of microtrabecular bone formation between the trabeculae of the underlying cancellous bone, which were not seen in the other groups, and more numerous osteoclast resorption pits. The calcified cartilage layer was almost absent and the bone plate was apparently thickened. The appearance of the osteoarthritic subchondral bone plate was, therefore, considerably different from both the normal and the osteoporotic, strongly indicative of abnormal cellular activity. PMID:10473297

  17. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    PubMed

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Slab fractures of the third tarsal bone: Minimally invasive repair using a single 3.5 mm cortex screw placed in lag fashion in 17 Thoroughbred racehorses.

    PubMed

    Barker, W H J; Wright, I M

    2017-03-01

    A technique for minimally invasive repair of slab fractures of the third tarsal bone has not previously been reported. Results of third tarsal bone slab fracture repair in Thoroughbred racehorses are lacking. To report the outcomes of repair of uniplanar frontal slab factures of the third tarsal bone using a single 3.5 mm cortex screw in lag fashion. Retrospective case series. Case records of horses that had undergone this procedure were reviewed. Seventeen horses underwent surgery. Eighteen percent of cases had wedge shaped third tarsal bones. A point midway between the long and lateral digital extensor tendons and centrodistal and tarsometatarsal joints created a suitable entry site for implants. The fracture location, configuration and curvature of the third tarsal bone and associated joints requires a dorsolateral proximal-plantaromedial distal trajectory for the screw, which was determined by preplaced needles. There were no complications and fractures healed in all cases at 4-6 months post surgery. Seventy-nine percent of horses returned to racing and, at the time of reporting, 3 are in post operative rehabilitation programmes. The technique reported provides a safe, appropriate and repeatable means of repairing slab fractures of the third tarsal bone. Surgical repair is a viable alternative to conservative management. © 2016 EVJ Ltd.

  19. Primary stability of different plate positions and the role of bone substitute in open wedge high tibial osteotomy.

    PubMed

    Takeuchi, Ryohei; Woon-Hwa, Jung; Ishikawa, Hiroyuki; Yamaguchi, Yuichiro; Osawa, Katsunari; Akamatsu, Yasushi; Kuroda, Koichi

    2017-12-01

    The purpose of this study was to compare the mechanical fixation strengths of anteromedial and medial plate positions in osteotomy, and clarify the effects of bone substitute placement into the osteotomy site. Twenty-eight sawbone tibia models were used. Four different models were prepared: Group A, the osteotomy site was open and the plate position was anteromedial; Group B, bone substitutes were inserted into the osteotomy site and the plate position was anteromedial; Group C, the osteotomy site was open and the plate position was medial; and Group D, bone substitutes were inserted into the osteotomy site and the plate position was medial. The loading condition ranged from 0 to 800N and one hertz cycles were applied. Changes of the tibial posterior slope angle (TPS), stress on the plate and lateral hinge were measured. The changes in the TPS and the stress on the plate were significantly larger in Group A than in Group C. These were significantly larger in Group A than in Group B, and in Group C than in Group D. There was no significant difference between Group B and Group D, and no significant difference between knee flexion angles of 0° and 10°. Stress on the lateral hinge was significantly smaller when bone substitute was used. A medial plate position was biomechanically superior to an anteromedial position if bone substitute was not used. Bone substitute distributed the stress concentration around the osteotomy gap and prevented an increase in TPS angle regardless of the plate position. Copyright © 2017. Published by Elsevier B.V.

  20. Comparison of open reduction versus minimally invasive surgical approaches on screw position in canine sacroiliac lag-screw fixation.

    PubMed

    Déjardin, Loïc M; Marturello, Danielle M; Guiot, Laurent P; Guillou, Reunan P; DeCamp, Charles E

    2016-07-19

    To compare accuracy and consistency of sacral screw placement in canine pelves treated for sacroiliac luxation with open reduction and internal fixation (ORIF) or minimally invasive osteosynthesis (MIO) techniques. Unilateral sacroiliac luxations created experimentally in canine cadavers were stabilized with an iliosacral lag screw applied via ORIF or MIO techniques (n = 10/group). Dorsoventral and craniocaudal screw angles were measured using computed tomography multiplanar reconstructions in transverse and dorsal planes, respectively. Ratios between pilot hole length and sacral width (PL/SW-R) were obtained. Data between groups were compared statistically (p <0.05). Mean screw angles (±SD) were greater in ORIF specimens in both transverse (p <0.001) and dorsal planes (p <0.004). Mean PL/SW-R was smaller (p <0.001) in the ORIF group, yet was greater than 60%. While pilot holes exited the first sacral end-plate in three of 10 ORIF specimens, the spinal canal was not violated in either group. This study demonstrates that MIO fixation of canine sacroiliac luxations provides more accurate and consistent sacral screw placement than ORIF. With proper techniques, iatrogenic neurological damage can be avoided with both techniques. The PL /SW-R, which relates to safe screw fixation, also demonstrates that screw penetration of at least 60% of the sacral width is achievable regardless of surgical approach. These findings, along with the limited dissection needed for accurate sacral screw placement, suggest that MIO of sacroiliac luxations is a valid alternative to ORIF.

  1. A comparitive clinical study between self tapping and drill free screws as a source of rigid orthodontic anchorage.

    PubMed

    Gupta, Nishant; Kotrashetti, S M; Naik, Vijay

    2012-03-01

    Self-tapping miniscrews are commonly being used as a temporary anchorage device for orthodontic purpose. A prerequisite for the insertion of these screws is the preparation of a pilot hole, which is time consuming and may result in damage to nerves, tooth root, drill bit breakage and thermal necrosis of bone. On the other hand the design of drill-free screws enables them to be inserted without drilling. The aim of this prospective study was to compare the stability and clinical response of the soft tissue around the self tapping and drill free screws when used for orthodontic anchorage for en mass retraction of maxillary anterior teeth. The study sample consisted of 20 patients requiring retraction of maxillary anterior teeth. The screws were placed in the alveolar bone between maxillary 2nd premolar and 1st molar bilaterally at the junction of attached gingiva and moveable mucosa. Pilot hole was drilled on the side which was selected for insertion of the self tapping screw under copious irrigation, after which it was inserted. Drill free screw was inserted on the contralateral side without predrilling. All screws were immediately loaded with 150-200 gm of retraction force. Patients were recalled for regular follow up for a period of 6 months. If the screws became mobile or showed any signs of inflammation during the course of the study, they were considered to be a failure. After a period of 6 months an overall success rate of 77.5% was noted. Four self tapping and five drill-free screws failed during the study. There was no statistically significant difference between the two types of screws with respect to success/failure. Mobility was found to be the major cause for the failure. Both self-tapping and the drill-free screws are effective anchorage units. But the latter have an edge over the conventional self-tapping screws because of decrease in operative time, little bone debris, less thermal damage, lower morbidity, and minimal patient discomfort as

  2. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.

    PubMed

    Grau, Luis; Collon, Kevin; Alhandi, Ali; Kaimrajh, David; Varon, Maria; Latta, Loren; Vilella, Fernando

    2018-06-01

    The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). Seven Sawbones® femur models had a Synthes VA-LCP placed as indicated by the manufacturers technique. A 4cm osteotomy was then created to simulate an AO/OTA 33-A3 femoral fracture pattern with metaphyseal comminution. The control group consisted of four constructs in which the open screw holes at the area of comminution were left unfilled; the experimental group consisted of three constructs in which the VA screw holes were filled with locking screws. One of the control constructs was statically loaded to failure at a rate of 5mm/min. A value equal to 75% of the ultimate load to failure was used as the loading force for fatigue testing of 250,000 cycles at 3Hz. Cycles to failure was recorded for each construct and averages were compared between groups. The average number of cycles to failure in the control and experimental groups were 37524±8187 and 43304±23835, respectively (p=0.72). No significant difference was observed with respect to cycles to failure or mechanism of failure between groups. In all constructs in both the control and experimental groups, plate failure reproducibly occurred with cracks through the variable angle holes in the area of bridged comminution. The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging

  3. Xenografts Supplemented with Pamindronate placed in postextraction sockets to avoid crestal bone resorption. Experimental study in Fox hound dogs.

    PubMed

    Lozano-Carrascal, Naroa; Delgado-Ruiz, Rafael Arcesio; Gargallo-Albiol, Jordi; Maté-Sánchez, José Eduardo; Hernandez Alfaro, Federico; Calvo-Guirado, José Luis

    2016-02-01

    The aim of the study was to compare the effects of porcine xenografts (MP3(®)) with or without pamindronate for the healing of small and large defects of postextraction sockets. Six beagle dogs were used in the study; second premolars and first molars of the mandible were extracted, small defects (SD) and large defects (LD) were identified. Each defect was measured and randomly filled as follows: SC (small control defects filled with MP3(®) alone), ST (small test defects filled with MP3(®) modified with pamindronate), LC (large control defects filled with MP3(®) alone), LT (large test defects filled with MP3(®) modified with pamindronate). After 4 and 8 weeks, the animals were euthanized and the percentages of new bone formation (NB), residual graft (RG) and connective tissue (CT) were analysed by histology and histomorphometry of undecalcified samples. After 4 weeks, NB formation was higher for ST compared to all groups and for LT compared to LC (P < 0.05); RG was significantly higher in both control groups compared to tests (P < 0.05); and CT was higher in large defects (LC and LT) compared to small defects. After 8 weeks, NB formation was higher for test groups (ST and LT) compared to controls (P < 0.05); RG was significantly higher in both control groups compared to tests (P < 0.05); and CT was higher in large defects (LC and LT) compared to small defects (P < 0.05). Within the limitations of this experimental study, the findings suggest that porcine xenografts modified with pamindronate favours the new bone formation and increased the porcine xenograft substitution/replacement after 4 and 8 weeks of healing. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Preoperative CT planning of screw length in arthroscopic Latarjet.

    PubMed

    Hardy, Alexandre; Gerometta, Antoine; Granger, Benjamin; Massein, Audrey; Casabianca, Laurent; Pascal-Moussellard, Hugues; Loriaut, Philippe

    2018-01-01

    The Latarjet procedure has shown its efficiency for the treatment of anterior shoulder dislocation. The success of this technique depends on the correct positioning and fusion of the bone block. The length of the screws that fix the bone block can be a problem. They can increase the risk of non-union if too short or be the cause of nerve lesion or soft tissue discomfort if too long. Suprascapular nerve injuries have been reported during shoulder stabilisation surgery up to 6 % of the case. Bone block non-union depending on the series is found around 20 % of the cases. The purpose of this study was to evaluate the efficiency of this CT preoperative planning to predict optimal screws length. The clinical importance of this study lies in the observation that it is the first study to evaluate the efficiency of CT planning to predict screw length. Inclusion criteria were patients with chronic anterior instability of the shoulder with an ISIS superior to 4. Exclusion criteria were patients with multidirectional instability or any previous surgery on this shoulder. Thirty patients were included prospectively, 11 of them went threw a CT planning, before their arthroscopic Latarjet. Optimal length of both screws was calculated, adding the size of the coracoid at 5 and 15 mm from the tip to the glenoid. Thirty-two-mm screws were used for patients without planning. On a post-operative CT scan with 3D reconstruction, the distance between the screw tip and the posterior cortex was measured. A one-sample Wilcoxon test was used to compare the distance from the tip of the screw to an acceptable positioning of ±2 mm from the posterior cortex. In the group without planning, screw 1 tended to differ from the acceptable positioning: mean 3.44 mm ± 3.13, med 2.9 mm, q1; q3 [0.6; 4.75] p = 0.1118, and screw 2 differed significantly from the acceptable position: mean 4.83 mm ± 4.11, med 3.7 mm, q1; q3 [1.7; 5.45] p = 0.0045. In the group with planning, position of

  5. Using three-dimensional rapid prototyping in the design and development of orthopaedic screws in standardised pull-out tests.

    PubMed

    Leslie, Laura Jane; Connolly, Ashley; Swadener, John G; Junaid, Sarah; Theivendran, Kanthan; Deshmukh, Subodh C

    2018-06-01

    The majority of orthopaedic screws are designed, tested and manufactured by existing orthopaedics companies and are predominantly developed with healthy bone in mind. The timescales and costs involved in the development of a new screw design, for example, for osteoporotic bone, are high. In this study, standard wood screws were used to analyse the concept of using three-dimensional printing, or rapid prototyping, as a viable stage of development in the design of a new bone screw. Six wood screws were reverse engineered and printed in polymeric material using stereolithography. Three of the designs were also printed in Ti6Al4V using direct metal laser sintering; however, these were not of sufficient quality to test further. Both the original metal screws (metal) and polymeric rapid prototyping screws were then tested using standard pull-out tests from low-density polyurethane blocks (Sawbones). Results showed the highest pull-out strengths for screws with the longest thread length and the smallest inner diameter. Of the six screw designs tested, five showed no more than a 17% variance between the metal and rapid prototyping results. A similar pattern of results was shown between the screw designs for both the metal and rapid prototyping screws in five of the six cases. While not producing fully comparable pull-out results to orthopaedic screws, the results from this study do provide evidence of the potential usefulness and cost-effectiveness of rapid prototyping in the early stages of design and testing of orthopaedic screws.

  6. Comparison between two pedicle screw augmentation instrumentations in adult degenerative scoliosis with osteoporosis.

    PubMed

    Xie, Yang; Fu, Qiang; Chen, Zi-qiang; Shi, Zhi-cai; Zhu, Xiao-dong; Wang, Chuan-feng; Li, Ming

    2011-12-21

    The operative treatment of adult degenerative scoliosis combined with osteoporosis increase following the epidemiological development. Studies have confirmed that screws in osteoporotic spines have significant lower-screw strength with more frequent screw movements within the vertebra than normal spines. Screws augmented with polymethylmethacrylate (PMMA) or with autogenous bone can offer more powerful corrective force and significant advantages. A retrospective analysis was conducted on 31 consecutive patients with degenerative lumbar scoliosis combined with osteoporosis who had surgery from December 2000. All had a minimum of 2-year follow-up. All patients had posterior approach surgery. 14 of them were fixed with pedicle screw by augmentation with polymethylmethacrylate (PMMA) and the other 17 patients with autogenous bone. Age, sex and whether smoking were similar between the two groups. Surgical time, blood loss, blood transfusion, medical cost, post surgery ICU time, hospital day, length of oral pain medicines taken, Pre-and postoperative Oswestry disability index questionnaire and surgical revision were documented and compared. Preoperative, postoperative and final follow up Cobb angle, sagittal lumbar curve, correction rate, and Follow up Cobb loss were also compared. No significant differences were found between the autogenous bone group and polymethylmethacrylate group with regards to all the targets above except for length of oral pain medicines taken and surgery cost. 2 patients were seen leakage during operation, but there is neither damage of nerve nor symptom after operation. No revision was needed. Both augmentation pedicle screw with polymethylmethacrylate (PMMA) and autogenous bone treating degenerative lumbar scoliosis combined with osteoporosis can achieve a good surgical result. Less oral pain medicines taken are the potential benefits of polymethylmethacrylate augmentation, but that is at the cost of more medical spending.

  7. Lateral mass screw-rod fixation of the cervical spine: a prospective clinical series with 1-year follow-up.

    PubMed

    Deen, H Gordon; Birch, Barry D; Wharen, Robert E; Reimer, Ronald

    2003-01-01

    Lateral mass plating has become the technique of choice for posterior cervical fixation. Although these systems are safe and reliable, they can be difficult to use in patients with abnormal cervical anatomy; screw placement can be compromised by the fixed hole spacing of the plate; screw back-out and other forms of implant failure can occur; and extension across the cervicothoracic junction can be problematic. To report a series of patients undergoing posterior cervical stabilization with a polyaxial screw-rod construct and to investigate whether this new system offers any advantages over existing methods of fixation. A prospective study evaluating clinical and radiographic parameters in a consecutive series of patients treated with this technique. There were 21 patients in the study group. The surgical indication was cervical spondylosis in 14, trauma in 2, postsurgical kyphosis in 2 and 1 case each of congenital cervicothoracic stenosis, C7-T1 pseudarthrosis and basilar invagination with brainstem compression. Clinical indicators included age, gender, neurologic status, surgical indication and number of levels stabilized. Note was made of whether laminectomy and concomitant anterior reconstructive surgery were performed. Radiographic indicators included early postoperative computed tomography (CT) scan to check for screw placement and plain radiographs at subsequent visits. The participants in this study underwent posterior cervical stabilization using lateral mass screw-rod fixation. Clinical and radiographic assessment was carried out immediately after surgery, and 3, 6 and 12 months after surgery. One-year follow-up was obtained in all cases. A total of 212 screws were implanted in 21 patients. Fixation was carried out over an average of 5.5 spinal segments (range, 2 to 11). The system was successfully implanted in all patients despite the presence of coronal and sagittal plane deformities and/or lateral mass abnormalities in the majority of cases. This system

  8. Biomechanical Comparisons of Pull Out Strengths After Pedicle Screw Augmentation with Hydroxyapatite, Calcium Phosphate, or Polymethylmethacrylate in the Cadaveric Spine.

    PubMed

    Yi, Seong; Rim, Dae-Cheol; Park, Seoung Woo; Murovic, Judith A; Lim, Jesse; Park, Jon

    2015-06-01

    In vertebrae with low bone mineral densities pull out strength is often poor, thus various substances have been used to fill screw holes before screw placement for corrective spine surgery. We performed biomechanical cadaveric studies to compare nonaugmented pedicle screws versus hydroxyapatite, calcium phosphate, or polymethylmethacrylate augmented pedicle screws for screw tightening torques and pull out strengths in spine procedures requiring bone screw insertion. Seven human cadaveric T10-L1 spines with 28 vertebral bodies were examined by x-ray to exclude bony abnormalities. Dual-energy x-ray absorptiometry scans evaluated bone mineral densities. Twenty of 28 vertebrae underwent ipsilateral fluoroscopic placement of 6-mm holes augmented with hydroxyapatite, calcium phosphate, or polymethylmethacrylate, followed by transpedicular screw placements. Controls were pedicle screw placements in the contralateral hemivertebrae without augmentation. All groups were evaluated for axial pull out strength using a biomechanical loading frame. Mean pedicle screw axial pull out strength compared with controls increased by 12.5% in hydroxyapatite augmented hemivertebrae (P = 0.600) and by 14.9% in calcium phosphate augmented hemivertebrae (P = 0.234), but the increase was not significant for either method. Pull out strength of polymethylmethacrylate versus hydroxyapatite augmented pedicle screws was 60.8% higher (P = 0.028). Hydroxyapatite and calcium phosphate augmentation in osteoporotic vertebrae showed a trend toward increased pedicle screw pull out strength versus controls. Pedicle screw pull out force of polymethylmethacrylate in the insertion stage was higher than that of hydroxyapatite. However, hydroxyapatite is likely a better clinical alternative to polymethylmethacrylate, as hydroxyapatite augmentation, unlike polymethylmethacrylate augmentation, stimulates bone growth and can be revised. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. [Advanced bone graft combined with locking compression plate for the treatment of middle and distal tibia nonunion].

    PubMed

    Zhao, Xue; Wang, Pan-feng; Zhang, Yun-tong; Zhang, Chun-cai; Xu, Shuo-gui; Zhang, Xin

    2014-12-01

    To explore methods of treating middle and distal tibia nonunion with the treatment of advanced bone graft combined with locking compression plate. From January 2011 to December 2012, 12 patients with middle and distal tibia nonunion were treated with advanced bone graft combined with locking compression plate. Among patients, there were 8 males and 4 females aged from 20 to 69 with an average of 47 years old. The time from first injuries to bone nonunion was from 9 months to 5 years, avergaed 19 months. Four cases were treated with external fixation, 6 cases were treated with plate fixation, 2 cases of 12 patients occurred broken of plate and nail. Eleven patients were non-infective bone nonunion and 1 patient was infective bone nonunion. Preoperative X-ray and CT showed all patients had sequestration and formation of ossified bone with different degrees. Operative time, blood loss, wound healing were observed, fracture healing time was evaluated by postoperative X-ray. Johner-Wruhs scoring standards was used to evaluate ankle joint function after operation at 10 months. Operative time ranged from 90 to 185 min with an average of (125.00±20.15) min; blood loss ranged from 225 to 750 ml with an average of (415.00±120.00) ml. All patients were followed up from 10 months to 2.5 years with an average of 1.5 years. Postoperative X-ray showed bone union was formed around fracture after operation at 4 months in all patients, 3 cases obtained bone healing within 6 months after operation, 9 cases obtained from 8 to 12 months. No infection, injury of nerve and vessles, and broken of plate and nail were ocurred. According to Johner-Wruhs scoring at 10 months after operation, 10 cases obtained excellent results, 1 good and 1 moderate. Advanced bone graft combined with locking compression plate, which can build fracture multi-point supporting based on full compression of bone nonunion to get effective fixation, is an effective method in treating middle and distal tibia

  10. Buccal bone deficiency in fresh extraction sockets: a prospective single cohort study.

    PubMed

    Barone, Antonio; Ricci, Massimiliano; Romanos, Georgios E; Tonelli, Paolo; Alfonsi, Fortunato; Covani, Ugo

    2015-07-01

    The purpose of this prospective single cohort study was to evaluate the use of xenograft and collagen membranes in treating full or partial buccal bone defects of fresh extraction sockets in the esthetic zone. Thirty-three patients requiring tooth extraction in the anterior maxillary area and showing a complete or partial buccal bone plate deficiency (more than 2 mm) were consecutively enrolled and treated. Corticocancellous porcine bone and platelet-rich fibrin (PRF) with a collagen membrane were used to graft the extraction sockets, and the membranes were left exposed to the oral cavity with a secondary soft tissue healing. The outcome variables were as follows: width of keratinized mucosa, facial soft tissue levels, clinical bone changes (measured with a clinical splint), implant and prosthesis failures, and peri-implant marginal bone changes. All treated sites allowed the placement of implants; the width of keratinized mucosa at the mid-facial aspect showed an increase of 2.3 mm 5 months after the grafting procedure, and its value was 3.2 ± 0.6 mm at 1-year follow-up. The mean values of the facial soft tissue level indicated an increase over time. The bone level showed an improvement of 0.8 ± 0.1 mm and 0.7 ± 0.1 mm at mesial and distal sites, respectively, when compared to the baseline measurements. Finally, in the palatal area, no bone changes were observed. No implant failed during the entire observation period. Findings from this study showed that xenograft and PRF, used for ridge preservation of the extraction sockets with buccal bone plate dehiscence in the esthetic zone, can be considered effective in repairing bone defects before implant placement. The secondary soft tissue healing over the grafted sockets did not compromise bone formation; moreover, the soft tissue level and the width of keratinized gingiva showed a significant improvement over time. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. A modified transcondylar screw to accommodate anatomical skull base variations.

    PubMed

    Ghaly, R F; Lissounov, A

    2017-01-01

    Occipitocervical instability may be attributed to congenital, bony/ligamentous abnormalities, trauma, neoplasm, degenerative bone disease, and failed atlantoaxial fixation. Indications for occipitocervical fixation include the prevention of disabling pain, cranial nerve dysfunction, paralysis, or even sudden death. The screw trajectory for the modified transcondylar screw (mTCS) is optimally planned utilizing a three-dimensional skull reconstructed image. The modified mTCS technique is helpful where there is a loss of bone, such as after prior suboccipital craniotomy and/or an inadequate occipital condyle. The new proposed technique is similar to the classical transcondylar screw placement but follows a deeper course along the bony lip of foramen magnum toward clivus from a dorsolateral approach. The modified mTCS technique allows for direct visualization and, therefore, helps to avoid damage to the hypoglossal nerve and lateral aspect of brain stem.

  12. Bone plate composed of a ternary nano-hydroxyapatite/polyamide 66/glass fiber composite: biomechanical properties and biocompatibility

    PubMed Central

    Qiao, Bo; Li, Jidong; Zhu, Qingmao; Guo, Shuquan; Qi, Xiaotong; Li, Weichao; Wu, Jun; Liu, Yang; Jiang, Dianming

    2014-01-01

    An ideal bone plate for internal fixation of bone fractures should have good biomechanical properties and biocompatibility. In this study, we prepared a new nondegradable bone plate composed of a ternary nano-hydroxyapatite/polyamide 66/glass fiber (n-HA/PA66/GF) composite. A breakage area on the n-HA/PA66/GF plate surface was characterized by scanning electron microscopy. Its mechanical properties were investigated using bone-plate constructs and biocompatibility was evaluated in vitro using bone marrow-derived mesenchymal stem cells. The results confirmed that adhesion between the n-HA/PA66 matrix and the glass fibers was strong, with only a few fibers pulled out at the site of breakage. Fractures fixed by the n-HA/PA66/GF plate showed lower stiffness and had satisfactory strength compared with rigid fixation using a titanium plate. Moreover, the results with regard to mesenchymal stem cell morphology, MTT assay, Alizarin Red S staining, enzyme-linked immunosorbent assay, and reverse transcription polymerase chain reaction for alkaline phosphatase and osteocalcin showed that the n-HA/PA66/GF composite was suitable for attachment and proliferation of mesenchymal stem cells, and did not have a negative influence on matrix mineralization or osteogenic differentiation of mesenchymal stem cells. These observations indicate that the n-HA/PA66/GF plate has good biomechanical properties and biocompatibility, and may be considered a new option for internal fixation in orthopedic surgery. PMID:24669191

  13. Bone plate composed of a ternary nano-hydroxyapatite/polyamide 66/glass fiber composite: biomechanical properties and biocompatibility.

    PubMed

    Qiao, Bo; Li, Jidong; Zhu, Qingmao; Guo, Shuquan; Qi, Xiaotong; Li, Weichao; Wu, Jun; Liu, Yang; Jiang, Dianming

    2014-01-01

    An ideal bone plate for internal fixation of bone fractures should have good biomechanical properties and biocompatibility. In this study, we prepared a new nondegradable bone plate composed of a ternary nano-hydroxyapatite/polyamide 66/glass fiber (n-HA/PA66/GF) composite. A breakage area on the n-HA/PA66/GF plate surface was characterized by scanning electron microscopy. Its mechanical properties were investigated using bone-plate constructs and biocompatibility was evaluated in vitro using bone marrow-derived mesenchymal stem cells. The results confirmed that adhesion between the n-HA/PA66 matrix and the glass fibers was strong, with only a few fibers pulled out at the site of breakage. Fractures fixed by the n-HA/PA66/GF plate showed lower stiffness and had satisfactory strength compared with rigid fixation using a titanium plate. Moreover, the results with regard to mesenchymal stem cell morphology, MTT assay, Alizarin Red S staining, enzyme-linked immunosorbent assay, and reverse transcription polymerase chain reaction for alkaline phosphatase and osteocalcin showed that the n-HA/PA66/GF composite was suitable for attachment and proliferation of mesenchymal stem cells, and did not have a negative influence on matrix mineralization or osteogenic differentiation of mesenchymal stem cells. These observations indicate that the n-HA/PA66/GF plate has good biomechanical properties and biocompatibility, and may be considered a new option for internal fixation in orthopedic surgery.

  14. Biomechanical Comparison of External Fixation and Compression Screws for Transverse Tarsal Joint Arthrodesis.

    PubMed

    Latt, L Daniel; Glisson, Richard R; Adams, Samuel B; Schuh, Reinhard; Narron, John A; Easley, Mark E

    2015-10-01

    Transverse tarsal joint arthrodesis is commonly performed in the operative treatment of hindfoot arthritis and acquired flatfoot deformity. While fixation is typically achieved using screws, failure to obtain and maintain joint compression sometimes occurs, potentially leading to nonunion. External fixation is an alternate method of achieving arthrodesis site compression and has the advantage of allowing postoperative compression adjustment when necessary. However, its performance relative to standard screw fixation has not been quantified in this application. We hypothesized that external fixation could provide transverse tarsal joint compression exceeding that possible with screw fixation. Transverse tarsal joint fixation was performed sequentially, first with a circular external fixator and then with compression screws, on 9 fresh-frozen cadaveric legs. The external fixator was attached in abutting rings fixed to the tibia and the hindfoot and a third anterior ring parallel to the hindfoot ring using transverse wires and half-pins in the tibial diaphysis, calcaneus, and metatarsals. Screw fixation comprised two 4.3 mm headless compression screws traversing the talonavicular joint and 1 across the calcaneocuboid joint. Compressive forces generated during incremental fixator foot ring displacement to 20 mm and incremental screw tightening were measured using a custom-fabricated instrumented miniature external fixator spanning the transverse tarsal joint. The maximum compressive force generated by the external fixator averaged 186% of that produced by the screws (range, 104%-391%). Fixator compression surpassed that obtainable with screws at 12 mm of ring displacement and decreased when the tibial ring was detached. No correlation was found between bone density and the compressive force achievable by either fusion method. The compression across the transverse tarsal joint that can be obtained with a circular external fixator including a tibial ring exceeds that

  15. A new palatal distractor device for bodily movement of maxillary bones by rigid self-locking miniplates and screws system.

    PubMed

    Cortese, Antonio; Savastano, Mauro; Cantone, Antonio; Claudio, Pier Paolo

    2013-07-01

    A new palatal distractor device for bodily movement of the maxillary bones after complete segmented Le Fort I osteotomy for 1-stage transversal distraction and tridimensional repositioning on 1 patient is presented. The new distractor has an intrinsic tridimensional rigidity also in the fixation system by self-locking miniplates and screws for better control of the 2 maxillary fragments during distraction. Le Fort I distraction and repositioning procedure in association with a bilateral sagittal split osteotomy were performed on 1 patient with complete solution of the cross-bite and class III malocclusion. Results of dental and cephalometric analysis performed before surgery (T1), after surgery and distraction time (T2), and 18 months after surgery and orthodontic appliance removal (T3) are reported. No complications were encountered using the new distractor device. Advantages of this device and technique are presented including improved rigidity of both distraction (jackscrew) and fixation (4 self-locking miniplates and screws) systems resulting in complete control of the position of the 2 maxillary fragments during distraction and surgery. In addition, this new device allows resuming palatal distraction in the event of cross-bite relapse without causing dental-related problems or the risks of screw slackening.

  16. Hounsfield unit of screw trajectory as a predictor of pedicle screw loosening after single level lumber interbody fusion.

    PubMed

    Sakai, Yusuke; Takenaka, Shota; Matsuo, Yohei; Fujiwara, Hiroyasu; Honda, Hirotsugu; Makino, Takahiro; Kaito, Takashi

    2018-06-01

    This study aims to clarify the clinical potential of Hounsfield unit (HU), measured on computed tomography (CT) images, as a predictor of pedicle screw (PS) loosening, compared to bone mineral density (BMD). A total of 206 screws in 52 patients (21 men and 31 women; mean age 68.2 years) were analyzed retrospectively. The screws were classified into two groups depending on their screw loosening status on 3-month follow-up CT (loosening screw group vs. non-loosening screw group). Preoperative HU of the trajectory was evaluated by superimposing preoperative and postoperative CT images using three-dimensional image analysis software. Age, sex, body mass index, screw size, BMD of lumbar, and HU of screw trajectory were analyzed in association with screw loosening. Multivariate logistic regression analysis was performed, and the thresholds for PS loosening risk factors were evaluated using a continuous numerical variable and receiver operating characteristic (ROC) curve analyses. The area under the curve (AUC) was used to determine the diagnostic performance, and values > 0.75 were considered to represent good performance. The loosening screw group contained 24 screws (12%). Multivariate analysis revealed that the significant independent risk factors were not BMD but male sex [P = 0.028; odds ratio (OR) 2.852, 95% confidence interval (CI) 1.120-7.258] and HU of screw trajectory (P = 0.006; OR 0.989, 95% CI 0.980-0.997). ROC curve analysis demonstrated that the AUC for HU of screw trajectory for women was 0.880 (95% CI 0.798-0.961). The cutoff value was 153.5. AUC for men was 0.635 (95% CI 0.449-0.821), which was not considered to be a good performance. Low HU of screw trajectories was identified as a risk factor of PS loosening for women. For female patients with low HU, additional augmentation is recommended to prevent PS loosening. Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  17. Arthroscopic anterior cruciate ligament reconstruction using the double press- fit technique: an alternative to interference screw fixation.

    PubMed

    Halder, Andreas M; Ludwig, Silke; Neumann, Wolfram

    2002-01-01

    Patellar tendon autograft fixation in arthroscopic anterior cruciate ligament reconstruction is commonly accomplished using interference screws. However, improper insertion of the screws may reduce primary stability, injure the posterior femoral cortex, or displace hardware into the joint. Even if placed properly, metallic screws interfere with postoperative magnetic resonance imaging. In case of revision surgery, removing screws may be difficult and leaves bone defects. Retrospective study. An arthroscopic technique was developed that achieves patellar tendon autograft fixation by press-fit without any supplemental internal fixation. Forty patients were examined clinically and by KT-1000 arthrometer 28.7 months (range, 22 to 40 months) postoperatively. The mean difference in side-to-side laxity was 1.3 mm (SD 2.2) and the results according to the IKDC score were as follows: 7 A, 28 B, 5 C, and 0 D. The double press-fit technique we present avoids all complications related to the use of interference screws and creates an ideal environment for osseous integration of the bone-patellar tendon-bone autograft. Concurrently, it achieves a stable fixation of the autograft and allows early functional rehabilitation. However, fixation strength depends on bone quality and the arthroscopic procedure is demanding.

  18. Correction Capability in the 3 Anatomic Planes of Different Pedicle Screw Designs in Scoliosis Instrumentation.

    PubMed

    Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy

    2017-05-01

    Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of

  19. CT scan based determination of optimal bone corridor for atlantoaxial ventral screw fixation in miniature breed dogs.

    PubMed

    Vizcaíno Revés, Núria; Stahl, Cristina; Stoffel, Michael; Bali, Monty; Forterre, Franck

    2013-10-01

    To describe the most reliable insertion angle, corridor length and width to place a ventral transarticular atlantoaxial screw in miniature breed dogs. Retrospective CT imaging study. Cervical CT scans of toy breed dogs (n = 21). Dogs were divided into 2 groups--group 1: no atlantoaxial abnormalities; group 2: atlantoaxial instability. Insertion angle in medial to lateral and ventral to dorsal direction was measured in group 1. Corridor length and width were measured in groups 1 and 2. Corridor width was measured at 3 points of the corridor. Each variable was measured 3 times and the mean used for statistical analysis. Mean ± SD optimal transarticular atlantoaxial insertion angle was determined to be 40 ± 1° in medial to lateral direction from the midline and 20 ± 1° in ventral to dorsal direction from the floor of the neural canal of C2. Mean corridor length was 7 mm (range, 4.5-8.0 mm). Significant correlation was found between corridor length, body weight, and age. Mean bone corridor width ranged from 3 to 5 mm. Statistically significant differences were found between individuals, gender and measured side. Optimal placement of a transarticular screw for atlantoaxial joint stabilization is very demanding because the screw path corridor is very narrow. © Copyright 2013 by The American College of Veterinary Surgeons.

  20. [Biomechanical study on effects of bone mineral density on fixation strength of expansive pedicle screw].

    PubMed

    Gao, Mingxuan; Li, Xusheng; Zhen, Ping; Wu, Zhigang; Zhou, Shenghu; Tian, Qi; Lei, Wei

    2013-08-01

    To evaluate the fixation strength of expansive pedicle screw (EPS) at different bone mineral density (BMD) levels, further to provide theoretical evidence for the clinical application of the EPS in patients with osteoporosis. Fresh human cadaver spines (T12-L5 spines) were divided into 4 levels: normal BMD, osteopenia, osteoporosis, and severe osteoporosis according to the value of BMD, 12 vertebra in each level. Conventional pedicle screw (CPS) or EPS was implanted into the bilateral vertebra in CPS group and EPS group, respectively, 12 screws in each group per BMD level. Screw pullout tests were conducted. The maximum pullout strength, stiffness, and energy absorption were determined by an AG-IS material testing machine with constant rate of loading in a speed of 5 mm/min. With the decline of BMD from normal to severe osteoporosis level, the maximum pullout strength and the stiffness correspondingly declined (P < 0.05). In CPS group, the energy absorption gradually decreased (P < 0.05); in EPS group, significant difference was found between other different BMD levels (P < 0.05) except between normal BMD and osteopenia and between osteoporosis and severe osteoporosis (P > 0.05). At the same BMD level, the maximum pullout strength of EPS group was significantly larger than that of CPS group (P < 0.05); the stiffness of EPS group was significantly higher than that of CPS group (P < 0.05) except one at normal BMD level; and no significant difference was found in the energy absorption between 2 groups (P > 0.05) except one at osteopenia level. No significant difference was found in maximum pullout strength, stiffness, and energy absorption between EPS group at osteoporosis level and CPS group at osteopenia level (P > 0.05); however, the maximum pullout strength, stiffness, and energy absorption of EPS group at severe osteoporosis level were significantly lower than those of CPS group at osteopenia level (P < 0.05). Compared with CPS, the EPS can significantly improve

  1. Bone condition of the maxillary zygomatic process prior to orthodontic anchorage plate fixation.

    PubMed

    Präger, T M; Brochhagen, H G; Mischkowski, R; Jost-Brinkmann, P G; Müller-Hartwich, R

    2015-01-01

    The clinical success of orthodontic miniplates depends on the stability of the miniscrews used for fixation. For good stability, it is essential that the application site provides enough bone of good quality. This study was performed to analyze the amount of bone available for orthodontic miniplates in the zygomatic process of the maxilla. We examined 51 dental CT scans (Somatom Plus 4; Siemens, Erlangen, Germany) obtained from 51 fully dentate adult patients (mean age 24.0 ± 8.1 years; 27 male and 24 female) prior to third molar surgery. The amount of bone in the zygomatic process region at the level of the first molar root tips and at several other cranial levels as far as 15 mm from the root tips was measured Bone thickness at the root tip level averaged 4.1 ± 1.0 mm; the lowest value measured at this level in any of the patients was 2.7 mm. Bone thickness averaged 8.3 ± 1.0 mm at 15 mm cranial to the root tips; 6.9 mm was the lowest value. The zygomatic process appears to provide sufficient bone to accommodate screws for miniplate fixation. While some patients may possess a borderline amount of bone at more caudal levels, lack of volume is not a problem near the zygomatic bone.

  2. PLIF with a titanium cage and excised facet joint bone for degenerative spondylolisthesis--in augmentation with a pedicle screw.

    PubMed

    Okuyama, Koichiro; Kido, Tadato; Unoki, Eiki; Chiba, Mitsuho

    2007-02-01

    To determine the validity of posterior lumbar interbody fusion (PLIF) using a titanium cage filled with excised facet joint bone and a pedicle screw for degenerative spondylolisthesis. PLIF using a titanium cage filled with excised facet joint bone and a pedicle screw was performed in 28 consecutive patients (men 10, women 18). The mean age of the patients was 60 years (range, 52 to 75 y) at the time of surgery. The mean follow-up period was 2.3 years (range, 2.0 to 4.5 y). The operation was done at L3/4 in 5, L4/5 in 20, and L3/4/5 in 3 patients. The mean operative bleeding was 318+/-151 g (mean+/-standard deviation), and the mean operative time was 3.34+/-0.57 hours per fixed segment. Clinical outcome was assessed by Denis' Pain and Work scale. Radiologic assessment was done using Boxell's method. Fusion outcome was assessed using an established criteria. On Pain scale, 20 and 8 patients were rated P4 and P5 before surgery, and 11, 12, 2, 2, and 1 patients were rated P1, P2, P3, P4, and P5 at final follow-up, respectively. On Work scale (for only physical labors), 12 and 9 patients were rated W4 and W5, before surgery, and 12, 5, 1, and 3 patients were rated W1, W2, W3 and W5 at final follow-up, respectively. There was significant difference in clinical outcome (P<0.01, Wilcoxon singled-rank test) The mean %Slip and Slip Angle was 17.9+/-8.1% and 3.9+/-5.8 degrees before surgery. The mean % Slip and Slip Angle was 5.4+/-4.4% and -2.0+/-4.8 degrees at final follow-up. There was a significant difference between the values (P<0.01, paired t test). "Union" and "probable union" was determined in 29 (93.5%) and 2 (6.5%) of 31 operated segments at 2.3 years (range, 2.0 to 4.5 y), postoperatively. PLIF using a titanium cage filled with excised facet joint bone and a pedicle screw provided a satisfactory clinical outcome and an excellent union rate without harvesting and grafting the autologous iliac bone.

  3. Biomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures.

    PubMed

    Aksakal, Bunyamin; Gurger, Murat; Say, Yakup; Yilmaz, Erhan

    2014-01-01

    Biomechanical comparison of straight DCP and helical plates for fixation of transversal and oblique tibial bone fractures were analyzed and compared to each other by axial compression, bending and torsion tests. An in vitro osteosynthesis of transverse (TF) and oblique bone fracture (OF) fixations have been analysed on fresh sheep tibias by using the DCP and helical compression plates (HP). Statistically significant differences were found for both DCP and helical plate fixations under axial compression, bending and torsional loads. The strength of fixation systems was in favor of DC plating with exception of the TF-HP fixation group under compression loads and torsional moments. The transvers fracture (TF) stability was found to be higher than that found in oblique fracture (OF) fixed by helical plates (HP). However, under torsional testing, compared to conventional plating, the helical plate fixations provided a higher torsional resistance and strength. The maximum stiffness at axial compression loading and maximum torsional strength was achieved in torsional testing for the TF-HP fixations. From in vitro biomechanical analysis, fracture type and plate fixation system groups showed different responses under different loadings. Consequently, current biomechanical analyses may encourage the usage of helical HP fixations in near future during clinical practice for transverse bone fractures.

  4. Accurate and Simple Screw Insertion Procedure With Patient-Specific Screw Guide Templates for Posterior C1-C2 Fixation.

    PubMed

    Sugawara, Taku; Higashiyama, Naoki; Kaneyama, Shuichi; Sumi, Masatoshi

    2017-03-15

    Prospective clinical trial of the screw insertion method for posterior C1-C2 fixation utilizing the patient-specific screw guide template technique. To evaluate the efficacy of this method for insertion of C1 lateral mass screws (LMS), C2 pedicle screws (PS), and C2 laminar screws (LS). Posterior C1LMS and C2PS fixation, also known as the Goel-Harms method, can achieve immediate rigid fixation and high fusion rate, but the screw insertion carries the risk of injury to neuronal and vascular structures. Dissection of venous plexus and C2 nerve root to confirm the insertion point of the C1LMS may also cause problems. We have developed an intraoperative screw guiding method using patient-specific laminar templates. Preoperative bone images of computed tomography (CT) were analyzed using three-dimensional (3D)/multiplanar imaging software to plan the trajectories of the screws. Plastic templates with screw guiding structures were created for each lamina using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all templates were specially designed to fit and lock on the lamina during the procedure. Surgery was performed using this patient-specific screw guide template system, and placement of the screws was postoperatively evaluated using CT. Twelve patients with C1-C2 instability were treated with a total of 48 screws (24 C1LMS, 20 C2PS, 4 C2LS). Intraoperatively, each template was found to exactly fit and lock on the lamina and screw insertion was completed successfully without dissection of the venous plexus and C2 nerve root. Postoperative CT showed no cortical violation by the screws, and mean deviation of the screws from the planned trajectories was 0.70 ± 0.42 mm. The multistep, patient-specific screw guide template system is useful for intraoperative screw navigation in posterior C1-C2 fixation. This simple and economical method can improve the accuracy of screw insertion, and reduce operation time and

  5. Comparison between two pedicle screw augmentation instrumentations in adult degenerative scoliosis with osteoporosis

    PubMed Central

    2011-01-01

    Background The operative treatment of adult degenerative scoliosis combined with osteoporosis increase following the epidemiological development. Studies have confirmed that screws in osteoporotic spines have significant lower-screw strength with more frequent screw movements within the vertebra than normal spines. Screws augmented with Polymethylmethacrylate (PMMA) or with autogenous bone can offer more powerful corrective force and significant advantages. Methods A retrospective analysis was conducted on 31 consecutive patients with degenerative lumbar scoliosis combined with osteoporosis who had surgery from December 2000. All had a minimum of 2-year follow-up. All patients had posterior approach surgery. 14 of them were fixed with pedicle screw by augmentation with Polymethylmethacrylate (PMMA) and the other 17 patients with autogenous bone. Age, sex and whether smoking were similar between the two groups. Surgical time, blood loss, blood transfusion, medical cost, post surgery ICU time, hospital day, length of oral pain medicines taken, Pre-and postoperative Oswestry disability index questionnaire and surgical revision were documented and compared. Preoperative, postoperative and final follow up Cobb angle, sagittal lumbar curve, correction rate, and Follow up Cobb loss were also compared. Results No significant differences were found between the autogenous bone group and Polymethylmethacrylate group with regards to all the targets above except for length of oral pain medicines taken and surgery cost. 2 patients were seen leakage during operation, but there is neither damage of nerve nor symptom after operation. No revision was needed. Conclusion Both augmentation pedicle screw with Polymethylmethacrylate (PMMA) and autogenous bone treating degenerative lumbar scoliosis combined with osteoporosis can achieve a good surgical result. Less oral pain medicines taken are the potential benefits of Polymethylmethacrylate augmentation, but that is at the cost of more

  6. A pilot trial comparing the tear-out behavior in screw-sockets and cemented polyethylene acetabular components - a cadaveric study.

    PubMed

    Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N

    2016-10-01

    The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes

  7. Effects of orthopedic implants with a polycaprolactone polymer coating containing bone morphogenetic protein-2 on osseointegration in bones of sheep.

    PubMed

    Niehaus, Andrew J; Anderson, David E; Samii, Valerie F; Weisbrode, Steven E; Johnson, Jed K; Noon, Mike S; Tomasko, David L; Lannutti, John J

    2009-11-01

    To determine elution characteristics of bone morphogenetic protein (BMP)-2 from a polycaprolactone coating applied to orthopedic implants and determine effects of this coating on osseointegration. 6 sheep. An in vitro study was conducted to determine BMP-2 elution from polycaprolactone-coated implants. An in vivo study was conducted to determine the effects on osseointegration when the polycaprolactone with BMP-2 coating was applied to bone screws. Osseointegration was assessed via radiography, measurement of peak removal torque and bone mineral density, and histomorphometric analysis. Physiologic response was assessed by measuring serum bone-specific alkaline phosphatase activity and uptake of bone markers. Mean +/- SD elution on day 1 of the in vitro study was 263 +/- 152 pg/d, which then maintained a plateau at 59.8 +/- 29.1 pg/d. Mean peak removal torque for screws coated with polycalprolactone and BMP-2 (0.91 +/- 0.65 dN x m) and screws coated with polycaprolactone alone (0.97 +/- 1.30 dN.m) did not differ significantly from that for the control screws (2.34 +/- 1.62 dN x m). Mean bone mineral densities were 0.535 +/- 0.060 g/cm(2), 0.596 +/- 0.093 g/cm(2), and 0.524 +/- 0.142 g/cm(2) for the polycaprolactone-BMP-2-coated, polycaprolactone-coated, and control screws, respectively, and did not differ significantly among groups. Histologically, bone was in closer apposition to the implant with the control screws than with either of the coated screws. BMP-2 within the polycaprolactone coating did not stimulate osteogenesis. The polycaprolactone coating appeared to cause a barrier effect that prevented formation of new bone. A longer period or use of another carrier polymer may result in increased osseointegration.

  8. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Riggs, Laura M; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S

    2010-01-01

    To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=15 pairs). For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.

  9. Local plate/rod descriptors of 3D trabecular bone micro-CT images from medial axis topologic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peyrin, Francoise; Attali, Dominique; Chappard, Christine

    Purpose: Trabecular bone microarchitecture is made of a complex network of plate and rod structures evolving with age and disease. The purpose of this article is to propose a new 3D local analysis method for the quantitative assessment of parameters related to the geometry of trabecular bone microarchitecture. Methods: The method is based on the topologic classification of the medial axis of the 3D image into branches, rods, and plates. Thanks to the reversibility of the medial axis, the classification is next extended to the whole 3D image. Finally, the percentages of rods and plates as well as their meanmore » thicknesses are calculated. The method was applied both to simulated test images and 3D micro-CT images of human trabecular bone. Results: The classification of simulated phantoms made of plates and rods shows that the maximum error in the quantitative percentages of plate and rods is less than 6% and smaller than with the structure model index (SMI). Micro-CT images of human femoral bone taken in osteoporosis and early or advanced osteoarthritis were analyzed. Despite the large physiological variability, the present method avoids the underestimation of rods observed with other local methods. The relative percentages of rods and plates were not significantly different between osteoarthritis and osteoporotic groups, whereas their absolute percentages were in relation to an increase of rod and plate thicknesses in advanced osteoarthritis with also higher relative and absolute number of nodes. Conclusions: The proposed method is model-independent, robust to surface irregularities, and enables geometrical characterization of not only skeletal structures but entire 3D images. Its application provided more accurate results than the standard SMI on simple simulated phantoms, but the discrepancy observed on the advanced osteoarthritis group raises questions that will require further investigations. The systematic use of such a local method in the characterization

  10. Randomised controlled trial of the sliding hip screw versus X-Bolt Dynamic Hip Plating System for the fixation of trochanteric fractures of the hip in adults: a protocol study for WHiTE 4 (WHiTE4).

    PubMed

    Griffin, Xavier L; Achten, Juul; Sones, William; Cook, Jonathan; Costa, Matthew L

    2018-01-26

    Sliding hip screw fixation is well established in the treatment of trochanteric fractures of the hip. The X-Bolt Dynamic Hip Plating System builds on the successful design features of the sliding hip screw but differs in the nature of the fixation in the femoral head. A randomised pilot study suggested that the X-bolt Dynamic Hip Plating System might provide similar health-related quality of life while reducing the risk of revision surgery when compared with the sliding hip screw. This is the protocol for a multicentre randomised trial of sliding hip screw versus X-Bolt Dynamic Hip Plating System for patients 60 years and over treated for a trochanteric fracture of the hip. Multicentre, multisurgeon, parallel, two-arm, randomised controlled trial. Patients aged 60 years and older with a trochanteric hip fracture are potentially eligible. Participants will be randomly allocated on a 1:1 basis to either sliding hip screw or X-Bolt Dynamic Hip Plating System. Otherwise, all care will be in accordance with National Institute for Health and Care Excellence guidance. A minimum of 1128 patients will be recruited to obtain 90% power to detect a 0.075-point difference in EuroQol-5D health-related quality of life at 4 months postrandomisation. Secondary outcomes include mortality, residential status, revision surgery and radiographic measures. The treatment effect will be estimated using a two-sided t-test adjusted for age, gender and cognitive impairment based on an intention-to-treat analysis. National Research Ethics Committee approved this study on 5 February 2016 (16/WM/0001). The study is sponsored by the University of Oxford and funded through an investigator initiated grant by X-Bolt Orthopaedics. A manuscript for a high-impact peer-reviewed journal will be prepared, and the results will be disseminated to patients through local mechanisms at participating centres. ISRCTN92825709. © Article author(s) (or their employer(s) unless otherwise stated in the text of the

  11. Embalmed and fresh frozen human bones in orthopedic cadaveric studies: which bone is authentic and feasible?

    PubMed Central

    2012-01-01

    Background and purpose The most frequently used bones for mechanical testing of orthopedic and trauma devices are fresh frozen cadaveric bones, embalmed cadaveric bones, and artificial composite bones. Even today, the comparability of these different bone types has not been established. Methods We tested fresh frozen and embalmed cadaveric femora that were similar concerning age, sex, bone mineral density, and stiffness. Artificial composite femora were used as a reference group. Testing parameters were pullout forces of cortex and cancellous screws, maximum load until failure, and type of fracture generated. Results Stiffness and type of fracture generated (Pauwels III) were similar for all 3 bone types (fresh frozen: 969 N/mm, 95% confidence interval (CI): 897–1,039; embalmed: 999 N/mm, CI: 875–1,121; composite: 946 N/mm, CI: 852–1,040). Furthermore, no significant differences were found between fresh frozen and embalmed femora concerning pullout forces of cancellous screws (fresh frozen: 654 N, CI: 471–836; embalmed: 595 N, CI: 365–823) and cortex screws (fresh frozen: 1,152 N, CI: 894–1,408; embalmed: 1,461 N, CI: 880–2,042), and axial load until failure (fresh frozen: 3,427 N, CI: 2,564–4290; embalmed: 3,603 N, CI: 2,898–4,306). The reference group showed statistically significantly different results for pullout forces of cancellous screws (2,344 N, CI: 2,068–2,620) and cortex screws (5,536 N, CI: 5,203–5,867) and for the axial load until failure (> 7,952 N). Interpretation Embalmed femur bones and fresh frozen bones had similar characteristics by mechanical testing. Thus, we suggest that embalmed human cadaveric bone is a good and safe option for mechanical testing of orthopedic and trauma devices. PMID:22978564

  12. Single-screw Fixation of Adolescent Salter-II Proximal Humeral Fractures: Biomechanical Analysis of the "One Pass Door Lock" Technique.

    PubMed

    Miller, Mark Carl; Redman, Christopher N; Mistovich, R Justin; Muriuki, Muturi; Sangimino, Mark J

    2017-09-01

    Pin fixation of Salter-II proximal humeral fractures in adolescents approaching skeletal maturity has potential complications that can be avoided with single-screw fixation. However, the strength of screw fixation relative to parallel and diverging pin fixation is unknown. To compare the biomechanical fixation strength between these fixation modalities, we used synthetic composite humeri, and then compared these results in composite bone with cadaveric humeri specimens. Parallel pinning, divergent pinning, and single-screw fixation repairs were performed on synthetic composite humeri with simulated fractures. Six specimens of each type were tested in axial loading and other 6 were tested in torsion. Five pair of cadaveric humeri were tested with diverging pins and single screws for comparison. Single-screw fixation was statistically stronger than pin fixation in axial and torsional loading in both composite and actual bone. There was no statistical difference between composite and cadaveric bone specimens. Single-screw fixation can offer greater stability to adolescent Salter-II fractures than traditional pinning. Single-screw fixation should be considered as a viable alternative to percutaneous pin fixation in transitional patients with little expected remaining growth.

  13. Quantification of osteoblastic activity in epiphyseal growth plates by quantitative bone SPECT/CT.

    PubMed

    Yamane, Tomohiko; Kuji, Ichiei; Seto, Akira; Matsunari, Ichiro

    2018-06-01

    Quantifying the function of the epiphyseal plate is worthwhile for the management of children with growth disorders. The aim of this retrospective study was to quantify the osteoblastic activity at the epiphyseal plate using the quantitative bone SPECT/CT. We enrolled patients under the age of 20 years who received Tc-99m hydroxymethylene diphosphonate bone scintigraphy acquired by a quantitative SPECT/CT scanner. The images were reconstructed by ordered subset conjugate-gradient minimizer, and the uptake on the distal margin of the femur was quantified by peak standardized uptake value (SUVpeak). A public database of standard body height was used to calculate growth velocities (cm/year). Fifteen patients (6.9-19.7 years, 9 female, 6 male) were enrolled and a total of 25 legs were analyzed. SUVpeak in the epiphyseal plate was 18.9 ± 2.4 (average ± standard deviation) in the subjects under 15 years and decreased gradually by aging. The SUVpeak correlated significantly with the age- and sex-matched growth velocity obtained from the database (R 2  = 0.83, p < 0.0001). The SUV measured by quantitative bone SPECT/CT was increased at the epiphyseal plates of children under the age of 15 years in comparison with the older group, corresponding to higher osteoblastic activity. Moreover, this study suggested a correlation between growth velocity and the SUV. Although this is a small retrospective pilot study, the objective and quantitative values measured by the quantitative bone SPECT/CT has the potential to improve the management of children with growth disorder.

  14. Development of a novel method for surgical implant design optimization through noninvasive assessment of local bone properties.

    PubMed

    Schiuma, D; Brianza, S; Tami, A E

    2011-03-01

    A method was developed to improve the design of locking implants by finding the optimal paths for the anchoring elements, based on a high resolution pQCT assessment of local bone mineral density (BMD) distribution and bone micro-architecture (BMA). The method consists of three steps: (1) partial fixation of the implant to the bone and creation of a reference system, (2) implant removal and pQCT scan of the bone, and (3) determination of BMD and BMA of all implant-anchoring locations along the actual and alternative directions. Using a PHILOS plate, the method uncertainty was tested on an artificial humerus bone model. A cadaveric humerus was used to quantify how the uncertainty of the method affects the assessment of bone parameters. BMD and BMA were determined along four possible alternative screw paths as possible criteria for implant optimization. The method is biased by a 0.87 ± 0.12 mm systematic uncertainty and by a 0.44 ± 0.09 mm random uncertainty in locating the virtual screw position. This study shows that this method can be used to find alternative directions for the anchoring elements, which may possess better bone properties. This modification will thus produce an optimized implant design. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Can we safely deform a plate to fit every bone? Population-based fit assessment and finite element deformation of a distal tibial plate.

    PubMed

    Harith, Hazreen; Schmutz, Beat; Malekani, Javad; Schuetz, Michael A; Yarlagadda, Prasad K

    2016-03-01

    Anatomically precontoured plates are commonly used to treat periarticular fractures. A well-fitting plate can be used as a tool for anatomical reduction of the fractured bone. Recent studies highlighted that some plates fit poorly for many patients due to considerable shape variations between bones of the same anatomical site. While it is impossible to design one shape that fits all, it is also burdensome for the manufacturers and hospitals to produce, store and manage multiple plate shapes without the certainty of utilization by a patient population. In this study, we investigated the number of shapes required for maximum fit within a given dataset, and if they could be obtained by manually deforming the original plate. A distal medial tibial plate was automatically positioned on 45 individual tibiae, and the optimal deformation was determined iteratively using finite element analysis simulation. Within the studied dataset, we found that: (i) 89% fit could be achieved with four shapes, (ii) 100% fit was impossible through mechanical deformation, and (iii) the deformations required to obtain the four plate shapes were safe for the stainless steel plate for further clinical use. The proposed framework is easily transferable to other orthopaedic plates. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Long-Term Degradation of Self-Reinforced Poly-Levo (96%)/Dextro (4%)-Lactide/β-Tricalcium Phosphate Biocomposite Interference Screws.

    PubMed

    Barber, F Alan; Dockery, W D

    2016-04-01

    To evaluate the long-term in vivo degradation of biocomposite interference screws made with self-reinforced poly-levo (96%)/dextro (4%)-lactide/β-tricalcium phosphate [SR-PL(96)/D(4)LA/β-TCP]. A study of the in vivo biologic behavior of an SR-PL(96)/D(4)LA/β-TCP biocomposite interference screw was initiated in 2011 using an anterior cruciate ligament (ACL) reconstruction model. Eight patients undergoing a bone-patellar tendon-bone ACL reconstruction fixed at both the femur and tibia with an SR-PL(96)/D(4)LA/β-TCP screw at least 36 months earlier were evaluated by physical, radiographic, and computed tomography (CT) evaluations. Lysholm, Tegner, Cincinnati, and International Knee Documentation Committee scores were obtained. After incomplete degradation was observed in these 8 patients, a subsequent series of 17 patients were evaluated at a minimum of 48 months after surgery. By use of CT scans, Hounsfield unit (HU) data were obtained at the femoral and tibial screw and other bone sites. An ossification quality score (range, 1 to 4) was used to determine osteoconductivity at the screw sites. Eleven male and 6 female patients evaluated by CT scan and radiographs at a mean of 50 months (range, 48 to 61 months) after surgery showed bone plug healing to the tunnel wall and the SR-PL(96)/D(4)LA/β-TCP screws were replaced with material that was calcified and non-trabecular. Osteoconductivity was present in 24 of 34 tunnels (70.58%) and nearly complete or complete (type 3 or 4 ossification) in 11 of 34 (32.35%). Mean screw site densities (femoral, 242 HU; tibial, 240 HU) were consistent with cancellous bone density. One positive pivot-shift test was found. Lysholm, Cincinnati, Tegner, and International Knee Documentation Committee activity scores improved from 44.5, 40.7, 2.3, and 1.4, respectively, preoperatively to 92, 92.4, 5.7, and 3.3, respectively, at follow-up (P < .0001). The average postoperative Single Assessment Numeric Evaluation score was 92. The mean KT

  17. Long-term outcome of cemented versus screw-retained implant-supported partial restorations.

    PubMed

    Nissan, Joseph; Narobai, Demitri; Gross, Ora; Ghelfan, Oded; Chaushu, Gavriel

    2011-01-01

    The present study was designed to compare the long-term outcome and complications of cemented versus screw-retained implant restorations in partially edentulous patients. Consecutive patients with bilateral partial posterior edentulism comprised the study group. Implants were placed, and cemented or screw-retained restorations were randomly assigned to the patients in a split-mouth design. Follow-up (up to 15 years) examinations were performed every 6 months in the first year and every 12 months in subsequent years. The following parameters were evaluated and recorded at each recall appointment: ceramic fracture, abutment screw loosening, metal frame fracture, Gingival Index, and marginal bone loss. Thirty-eight patients were treated with 221 implants to support partial prostheses. No implants during the follow-up period (mean follow-up, 66 ± 47 months for screw-retained restorations [range, 18 to 180 months] and 61 ± 40 months for cemented restorations [range, 18 to 159 months]). Ceramic fracture occurred significantly more frequently (P < .001) in screw-retained (38% ± 0.3%) than in cemented (4% ± 0.1%) restorations. Abutment screw loosening occurred statistically significantly more often (P = .001) in screw-retained (32% ± 0.3%) than in cement-retained (9% ± 0.2%) restorations. There were no metal frame fractures in either type of restoration. The mean Gingival Index scores were statistically significantly higher (P < .001) for screw-retained (0.48 ± 0.5) than for cemented (0.09 ± 0.3) restorations. The mean marginal bone loss was statistically significantly higher (P < .001) for screw-retained (1.4 ± 0.6 mm) than for cemented (0.69 ± 0.5 mm) restorations. The long-term outcome of cemented implant-supported restorations was superior to that of screw-retained restorations, both clinically and biologically.

  18. Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model.

    PubMed

    Beer, Andreas; Gahleitner, André; Holm, Anders; Birkfellner, Wolfgang; Homolka, Peter

    2007-02-01

    The aim of this study was to quantify the effect of adapted preparation on the insertion torque of self-tapping implants in cancellous bone. In adapted preparation, bone condensation - and thus, insertion torque - is controlled by changing the diameter of the drilling. After preparation of cancellous porcine vertebral bone with drills of 2.85, 3, 3.15 or 3.35 mm final diameters, Brånemark sytem Mk III implants (3.75 x 11.5 mm) were inserted in 141 sites. During implantation, the insertion torque was recorded. Prior to implant insertion, bone mineralization (bone mineral density (BMD)) was measured with dental quantative computed tomography. The BMD values measured at the implant position were correlated with insertion torque for varying bone condensation. Based on the average torque recorded during implant insertion into the pre-drilled canals with a diameter of 3 mm, torque increased by approximately 17% on reducing the diameter of the drill by 5% (to 2.85 mm). On increasing the diameter of the osteotomy to 3.15 mm (5%) or 3.35 mm (12%), torque values decreased by approximately 21% and 50%, respectively. The results demonstrate a correlation between primary stability (average insertion torque) and the diameter of the implant bed on using a screw-shaped implant. Thus, using an individualized bone mineralization-dependent drilling technique, optimized torque values could be achieved in all tested bone qualities with BMDs ranging from 330 to 500 mg/cm(3). The results indicate that using a bone-dependent drilling technique, higher torque values can also be achieved in poor bone using an individualized drilling resulting in higher bone condensation. As immediate function is dependent on primary stability (high insertion torque), this indicates that primary stability can be increased using a modified drilling technique in lesser mineralized bone.

  19. Biomechanics of lateral lumbar interbody fusion constructs with lateral and posterior plate fixation: laboratory investigation.

    PubMed

    Fogel, Guy R; Parikh, Rachit D; Ryu, Stephen I; Turner, Alexander W L

    2014-03-01

    Lumbar interbody fusion is indicated in the treatment of degenerative conditions. Laterally inserted interbody cages significantly decrease range of motion (ROM) compared with other cages. Supplemental fixation options such as lateral plates or spinous process plates have been shown to provide stability and to reduce morbidity. The authors of the current study investigate the in vitro stability of the interbody cage with a combination of lateral and spinous process plate fixation and compare this method to the established bilateral pedicle screw fixation technique. Ten L1-5 specimens were evaluated using multidirectional nondestructive moments (± 7.5 N · m), with a custom 6 degrees-of-freedom spine simulator. Intervertebral motions (ROM) were measured optoelectronically. Each spine was evaluated under the following conditions at the L3-4 level: intact; interbody cage alone (stand-alone); cage supplemented with lateral plate; cage supplemented with ipsilateral pedicle screws; cage supplemented with bilateral pedicle screws; cage supplemented with spinous process plate; and cage supplemented with a combination of lateral plate and spinous process plate. Intervertebral rotations were calculated, and ROM data were normalized to the intact ROM data. The stand-alone laterally inserted interbody cage significantly reduced ROM with respect to the intact state in flexion-extension (31.6% intact ROM, p < 0.001), lateral bending (32.5%, p < 0.001), and axial rotation (69.4%, p = 0.002). Compared with the stand-alone condition, addition of a lateral plate to the interbody cage did not significantly alter the ROM in flexion-extension (p = 0.904); however, it was significantly decreased in lateral bending and axial rotation (p < 0.001). The cage supplemented with a lateral plate was not statistically different from bilateral pedicle screws in lateral bending (p = 0.579). Supplemental fixation using a spinous process plate was not significantly different from bilateral pedicle

  20. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.

    PubMed

    Tabata, Tomonori; Kaku, Nobuhiro; Hara, Katsutoshi; Tsumura, Hiroshi

    2015-04-01

    Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on initial cup stability. Foam bone was subjected to exact hemispherical-shape machining to diameters of 48, 48.5 and 49 mm. A compressive force was applied to ensure seating of a 48-mm-diameter acetabular cup in the foam bone prior to testing. Screws were inserted in six different conditions and tightened in a radial direction at the same torque strength. Then, the socket was rotated with a twist-testing machine, and the torque value at the start of axial rotation between the socket and the foam bone was measured under each screw condition. The torque values for the 48-mm-diameter reaming were >20 N m higher than those for the 48.5- and 49-mm-diameter reaming in each screw condition, indicating that press-fit fixation is stronger than screw fixation. Meanwhile, torque values for the 48.5- and 49-mm-diameter reaming tended to increase with increasing the number of screws. According to our experiment, press-fit fixation of a cementless acetabular cup achieved rigid stability. Although the supplemental screws increased stability of the implant under good press-fit conditions, they showed little impact on whole-cup stability. In the case of insufficient press-fit fixation, cup stability depends on screw stability and increasing the number of additional screws increases cup stability.

  1. Volumetric topological analysis: a novel approach for trabecular bone classification on the continuum between plates and rods.

    PubMed

    Saha, Punam K; Xu, Yan; Duan, Hong; Heiner, Anneliese; Liang, Guoyuan

    2010-11-01

    Trabecular bone (TB) is a complex quasi-random network of interconnected plates and rods. TB constantly remodels to adapt to the stresses to which it is subjected (Wolff's Law). In osteoporosis, this dynamic equilibrium between bone formation and resorption is perturbed, leading to bone loss and structural deterioration. Both bone loss and structural deterioration increase fracture risk. Bone's mechanical behavior can only be partially explained by variations in bone mineral density, which led to the notion of bone structural quality. Previously, we developed digital topological analysis (DTA) which classifies plates, rods, profiles, edges, and junctions in a TB skeletal representation. Although the method has become quite popular, a major limitation of DTA is that it provides only hard classifications of different topological entities, failing to distinguish between narrow and wide plates. Here, we present a new method called volumetric topological analysis (VTA) for regional quantification of TB topology. At each TB location, the method uniquely classifies its topology on the continuum between perfect plates and perfect rods, facilitating early detections of TB alterations from plates to rods according to the known etiology of osteoporotic bone loss. Several new ideas, including manifold distance transform, manifold scale, and feature propagation have been introduced here and combined with existing DTA and distance transform methods, leading to the new VTA technology. This method has been applied to multidetector computed tomography (CT) and micro-computed tomography ( μCT) images of four cadaveric distal tibia and five distal radius specimens. Both intra- and inter-modality reproducibility of the method has been examined using repeat CT and μCT scans of distal tibia specimens. Also, the method's ability to predict experimental biomechanical properties of TB via CT imaging under in vivo conditions has been quantitatively examined and the results found are very

  2. Conventional bone plate fixation of distal radius and ulna fractures in toy breed dogs.

    PubMed

    Ramírez, J M; Macías, C

    2016-03-01

    To describe the outcome of bone plate fixation of distal radius and ulna fractures in toy breed dogs treated with conventional bone plates. Records of 15 toy breed dogs with distal radius and ulna fractures were retrospectively reviewed for signalment, method of fixation, complications and clinical and radiographic assessments. A telephone-based owner questionnaire was conducted to determine long-term function and client satisfaction. Age ranged from 4 months to 6 years. Body weight ranged from 1 to 4 kg. Dynamic compression plates were used in 13 dogs and veterinary cuttable plates were used in 2 dogs as the means of fixation. Full radiographic and clinical follow-up data were available for 10 dogs and follow-up was performed between 6 and 8 weeks postoperatively. At that time, all fractures had healed and return to function was considered excellent in all 10 dogs. Five dogs did not return for hospital evaluation because they were judged by their owners to be free of lameness. In two cases, owners could not be contacted by telephone, but the referring veterinarians reported the dogs to be asymptomatic. No major complications occurred. Conventional bone plates are suitable choices for stabilisation of distal radius and ulna fractures in toy breed dogs and are not necessarily correlated with high rates of complication. © 2016 Australian Veterinary Association.

  3. In vitro and in vivo studies on the degradation of high-purity Mg (99.99wt.%) screw with femoral intracondylar fractured rabbit model.

    PubMed

    Han, Pei; Cheng, Pengfei; Zhang, Shaoxiang; Zhao, Changli; Ni, Jiahua; Zhang, Yuanzhuang; Zhong, Wanrun; Hou, Peng; Zhang, Xiaonong; Zheng, Yufeng; Chai, Yimin

    2015-09-01

    High-purity magnesium (HP Mg) takes advantage in no alloying toxic elements and slower degradation rate in lack of second phases and micro-galvanic corrosion. In this study, as rolled HP Mg was fabricated into screws and went through in vitro immersion tests, cytotoxicity test and bioactive analysis. The HP Mg screws performed uniform corrosion behavior in vitro, and its extraction promoted cell viability, bone alkaline phosphatase (ALP) activity, and mRNA expression of osteogenic differentiation related gene, i.e. ALP, osteopontin (OPN) and RUNX2 of human bone marrow mesenchymal stem cells (hBMSCs). Then HP Mg screws were implanted in vivo as load-bearing implant to fix bone fracture and subsequently gross observation, range of motion (ROM), X-ray scanning, qualitative micro-computed tomography (μCT) analysis, histological analysis, bending-force test and SEM morphology of retrieved screws were performed respectively at 4, 8, 16 and 24 weeks. As a result, the retrieved HP Mg screws in fixation of rabbit femoral intracondylar fracture showed uniform degradation morphology and enough bending force. However, part of PLLA screws was broken in bolt, although its screw thread was still intact. Good osseointegration was revealed surrounding HP Mg screws and increased bone volume and bone mineral density were detected at fracture gap, indicating the rigid fixation and enhanced fracture healing process provided by HP Mg screws. Consequently, the HP Mg showed great potential as internal fixation devices in intra-articular fracture operation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Finite element analysis of stress distribution on the mandible and condylar fracture osteosynthesis during various clenching tasks.

    PubMed

    Hijazi, Loai; Hejazi, Wael; Darwich, Mhd Ayham; Darwich, Khaldoun

    2016-12-01

    The purpose of the study was to evaluate the effect of clenching tasks on the stress and strain of condylar osteosynthesis screws and plates, as well as on the stress, strain distribution and displacement on the whole mandible and bone surrounding screws. Three-dimensional finite element models of the mandible, two straight four-hole plates and eight screws were established. Six static clenching tasks were simulated in this study: incisal clench (INC), intercuspal position (ICP), right unilateral molar clench (RMOL), left unilateral molar clench (LMOL), right group function (RGF) and left group function (LGF). Based on the simulation of the six clenching tasks, none of the inserted screws and plates were broken or bended. For the whole mandibular bone, the maximum von Mises stress and von Mises strain observed were yielded by the ICP. For the bone surrounding the inserted screws, the maximum von Mises stress and von Mises strain were yielded by the LMOL (49.2 MPa and 3795.1 μ). Clenching tasks had significant effects on the stress distribution on the condylar osteosynthesis and the bone surrounding screws. Contralateral occlusion task (LMOL) had the maximal results of von Mises stress and strain and healing problems could be occur, this result confirms the importance of soft diet after surgery.

  5. Biomechanical analysis of two fixation methods for proximal chevron osteotomy of the first metatarsal.

    PubMed

    Schuh, Reinhard; Hofstaetter, Jochen Gerhard; Benca, Emir; Willegger, Madeleine; von Skrbensky, Gobert; Zandieh, Shahin; Wanivenhaus, Axel; Holinka, Johannes; Windhager, Reinhard

    2014-05-01

    The proximal chevron osteotomy provides high correctional power. However, relatively high rates of dorsiflexion malunion of up to 17 % are reported for this procedure. This leads to insufficient weight bearing of the first ray and therefore to metatarsalgia. Recent biomechanical and clinical studies pointed out the importance of rigid fixation of proximal metatarsal osteotomies. Therefore, the aim of the present study was to compare biomechanical properties of fixation of proximal chevron osteotomies with variable locking plate and cancellous screw respectively. Ten matched pairs of human fresh frozen cadaveric first metatarsals underwent proximal chevron osteotomy with either variable locking plate or cancellous screw fixation after obtaining bone mineral density. Biomechanical testing included repetitive plantar to dorsal loading from 0 to 31 N with the 858 Mini Bionix(®) (MTS(®) Systems Corporation, Eden Prairie, MN, USA). Dorsal angulation of the distal fragment was recorded. The variable locking plate construct reveals statistically superior results in terms of bending stiffness and dorsal angulation compared to the cancellous screw construct. There was a statistically significant correlation between bone mineral density and maximum tolerated load until construct failure occurred for the screw construct (r = 0.640, p = 0.406). The results of the present study indicate that variable locking plate fixation shows superior biomechanical results to cancellous screw fixation for proximal chevron osteotomy. Additionally, screw construct failure was related to levels of low bone mineral density. Based on the results of the present study we recommend variable locking plate fixation for proximal chevron osteotomy, especially in osteoporotic bone.

  6. Cyp26b1 within the growth plate regulates bone growth in juvenile mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minegishi, Yoshiki; Department of Plastic and Reconstructive Surgery, University of Fukui Hospital, 23-3 Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui 910-1193; Department of Plastic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871

    Highlights: • Retinoic acid and Cyp26b1 were oppositely localized in growth plate cartilage. • Cyp26b1 deletion in chondrocytes decreased bone growth in juvenile mice. • Cyp26b1 deletion reduced chondrocyte proliferation and growth plate height. • Vitamin A-depletion partially reversed growth plate abnormalities caused by Cyp26b1 deficiency. • Cyp26b1 regulates bone growth by controlling chondrocyte proliferation. - Abstract: Retinoic acid (RA) is an active metabolite of vitamin A and plays important roles in embryonic development. CYP26 enzymes degrade RA and have specific expression patterns that produce a RA gradient, which regulates the patterning of various structures in the embryo. However, itmore » has not been addressed whether a RA gradient also exists and functions in organs after birth. We found localized RA activities in the diaphyseal portion of the growth plate cartilage were associated with the specific expression of Cyp26b1 in the epiphyseal portion in juvenile mice. To disturb the distribution of RA, we generated mice lacking Cyp26b1 specifically in chondrocytes (Cyp26b1{sup Δchon} cKO). These mice showed reduced skeletal growth in the juvenile stage. Additionally, their growth plate cartilage showed decreased proliferation rates of proliferative chondrocytes, which was associated with a reduced height in the zone of proliferative chondrocytes, and closed focally by four weeks of age, while wild-type mouse growth plates never closed. Feeding the Cyp26b1 cKO mice a vitamin A-deficient diet partially reversed these abnormalities of the growth plate cartilage. These results collectively suggest that Cyp26b1 in the growth plate regulates the proliferation rates of chondrocytes and is responsible for the normal function of the growth plate and growing bones in juvenile mice, probably by limiting the RA distribution in the growth plate proliferating zone.« less

  7. Persistent non-union of the humeral shaft treated by plating and autologous bone grafting.

    PubMed

    Pollon, Tristan; Reina, Nicolas; Delclaux, Stéphanie; Bonnevialle, Paul; Mansat, Pierre; Bonnevialle, Nicolas

    2017-02-01

    Surgical treatment of persistent non-union of the humeral shaft is a complex situation because of the risk of failure and surgery-related complications. The primary objective of this study was to evaluate clinical and radiological results of a continuous series of persistent non-union treated with plating and bone grafting. The secondary objective was to expose factors contributing to the failure of prior bone union attempts. Sixteen patients (average age of 52 years) were treated for persistent non-union of the humeral shaft in our department; six of these patients had predisposing comorbidities or addictions. The persistent non-union was treated by plating with autologous bone graft from the iliac crest in a single-stage procedure in 12 cases and a two-stage procedure in three cases; one case was treated with plating and vascularized fibula graft. At a minimum follow-up of 12 months (average 78 months), four (25 %) failed to heal. The 12 other patients had bone union after an average of eight months. The average QuickDASH score was 48 points (18-72). A retrospective analysis of the prior attempts to treat the non-union revealed three cases of unstable fixation, four cases with no osteogenic supply and seven cases of positive microbiological cultures at the non-union site. Plating and autologous bone grafting resulted in union in only 75 % of persistent non-union of the humeral shaft. The persistent nature of the humeral shaft non-union could be attributed to deviating from validated rules for surgical treatment and/or the presence of a surgical site infection.

  8. A new adhesive technique for internal fixation in midfacial surgery

    PubMed Central

    Endres, Kira; Marx, Rudolf; Tinschert, Joachim; Wirtz, Dieter Christian; Stoll, Christian; Riediger, Dieter; Smeets, Ralf

    2008-01-01

    Background The current surgical therapy of midfacial fractures involves internal fixation in which bone fragments are fixed in their anatomical positions with osteosynthesis plates and corresponding screws until bone healing is complete. This often causes new fractures to fragile bones while drilling pilot holes or trying to insert screws. The adhesive fixation of osteosynthesis plates using PMMA bone cement could offer a viable alternative for fixing the plates without screws. In order to achieve the adhesive bonding of bone cement to cortical bone in the viscerocranium, an amphiphilic bone bonding agent was created, analogous to the dentin bonding agents currently on the market. Methods The adhesive bonding strengths were measured using tension tests. For this, metal plates with 2.0 mm diameter screw holes were cemented with PMMA bone cement to cortical bovine bone samples from the femur diaphysis. The bone was conditioned with an amphiphilic bone bonding agent prior to cementing. The samples were stored for 1 to 42 days at 37 degrees C, either moist or completely submerged in an isotonic NaCl-solution, and then subjected to the tension tests. Results Without the bone bonding agent, the bonding strength was close to zero (0.2 MPa). Primary stability with bone bonding agent is considered to be at ca. 8 MPa. Moist storage over 42 days resulted in decreased adhesion forces of ca. 6 MPa. Wet storage resulted in relatively constant bonding strengths of ca. 8 MPa. Conclusion A new amphiphilic bone bonding agent was developed, which builds an optimizied interlayer between the hydrophilic bone surface and the hydrophobic PMMA bone cement and thus leads to adhesive bonding between them. Our in vitro investigations demonstrated the adhesive bonding of PMMA bone cement to cortical bone, which was also stable against hydrolysis. The newly developed adhesive fixing technique could be applied clinically when the fixation of osteosynthesis plates with screws is impossible. With

  9. The strength of polyaxial locking interfaces of distal radius plates.

    PubMed

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  10. Construct stability of an instrumented 2-level cervical corpectomy model following fatigue testing: biomechanical comparison of circumferential antero-posterior instrumentation versus a novel anterior-only transpedicular screw-plate fixation technique.

    PubMed

    Koller, Heiko; Schmoelz, Werner; Zenner, Juliane; Auffarth, Alexander; Resch, Herbert; Hitzl, Wolfgang; Malekzadeh, Davud; Ernstbrunner, Lukas; Blocher, Martina; Mayer, Michael

    2015-12-01

    A high rate of complications in multilevel cervical surgery with corpectomies and anterior-only screw-and-plate stabilization is reported. A 360°-instrumentation improves construct stiffness and fusion rates, but adds the morbidity of a second approach. A novel ATS-technique (technique that used anterior transpedicular screw placement) was recently described, yet no study to date has analyzed its performance after fatigue loading. Accordingly, the authors performed an analysis of construct stiffness after fatigue testing of a cervical 2-level corpectomy model reconstructed using a novel anterior transpedicular screw-and-plate technique (ATS-group) in comparison to standard antero-posterior instrumentation (360°-group). Twelve fresh-frozen human cervical spines were mounted on a spine motion tester to analyze restriction of ROM under loading (1.5 Nm) in flexion-extension (FE), axial rotation (AR), and lateral bending (LB). Testing was performed in the intact state, and after instrumentation of a 2-level corpectomy C4 + C5 using a cage and the constructs of ATS- and 360°-group, after 1,000 cycles, and after 2,000 cycles of fatigue testing. In the ATS-group (n = 6), instrumentation was achieved using a customized C3-C6 ATS-plate system. In the 360°-group (n = 6), instrumentation consisted of a standard anterior screw-and-plate system with a posterior instrumentation using C3-C6 lateral mass screws. Motion data were assessed as degrees and further processed as normalized values after standardization to the intact ROM state. Specimen age and BMD were not significantly different between the ATS- and 360°-groups. After instrumentation and 2,000 cycles of testing, no specimen exhibited a ROM greater than in the intact state. No specimen exhibited catastrophic construct failure after 2,000 cycles. Construct stiffness in the 360°-group was significantly increased compared to the ATS-group for all loading conditions, except for FE-testing after instrumentation. After 2

  11. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S; Gill, Marjorie S

    2007-12-01

    To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP-TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=18 pairs). For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0-7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP-TLS fixation. Mean (+/- SD) values for the ESP and DCP-TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 +/- 8.96 and 28.5 +/- 3.32 kN; stiffness, 13.11 +/- 0.242 and 2.60 +/- 0.17 kN/cm; and failure load, 144.4 +/- 13.6 and 31.4 +/- 3.8 kN. In single cycle to failure under torsion, mean (+/- SD) values for ESP and DCP-TLS, respectively, were: stiffness 2,022 +/- 26.2 and 107.9 +/- 11.1 N m

  12. Surgical treatment of sagittal fracture of mandibular condyle using long-screw osteosynthesis.

    PubMed

    Luo, Shufang; Li, Bo; Long, Xing; Deng, Mohong; Cai, Hengxing; Cheng, Yong

    2011-07-01

    The retrospective study evaluated long-screw (bicortical screw) osteosynthesis used in the surgical treatment of sagittal fracture of the mandibular condyle and compared it with titanium plates and removal of the condylar fragment. Ninety-five patients with sagittal fracture of the mandibular condyle received open surgical treatment from 1997 to 2008. Among these patients, the condylar fragments were fixed with long screws in 56 cases (group A), were fixed with titanium plates in 12 cases (group B), and were completely removed in 24 cases (group C). Follow-up was carried out clinically and radiologically. The clinical features included limitation of mandibular mobility, occlusion disturbance, lateral deviation on mouth opening, joint pain, clicking, facial asymmetry, and patient's subjective evaluation. The radiologic parameters consisted of degree of bony resorption, bony change, change of osteosynthesis material, and shortening of mandibular ramus height. Anatomic reduction and functional restoration were obtained and no severe complication was detected in group A. However, 3 of 14 patients had severe osteoarthrosis and 2 of 14 patients had ankylosis in group B. In group C 3 of 24 patients had mandibular retrusion, 4 of 24 patients had front teeth open bite, 4 of 24 patients had severe osteoarthrosis, and 1 of 24 patients had ankylosis. The long-screw fixation group had a more favorable prognosis than the titanium plate group and the group in which removal of the condylar fragment was performed. The long-screw fixation technique might be suitable for use in the surgical treatment of sagittal fractures of the mandibular condyle. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Investigation on Tensile Fatigue Characteristics of Meshed GUM Metal Plates for Bone Graft Applications

    NASA Astrophysics Data System (ADS)

    Sekiguchi, Koki; He, Jianmei

    2017-11-01

    GUM Metal has characteristics of lower elasticity rigidity, large elastic deformation, higher strength and biocompatibility etc. When it is used for implant applications, there is still problem like overloading on the natural-bone because of its high rigidity compared with the human bones. Therefore, the purpose of this study is to create more flexible meshed plates for implant applications from the viewpoints of elastic rigidity and volume density. Basic mesh shapes are designed, devised and applied for meshed GUM Metal plates using three dimensional (3D) CAD tools. Experimental evaluation on tensile fatigue characteristics of meshed GUM Metal plate specimens are carried out. Analytical approaches on stress evaluation are also executed through finite element method to obtain the S-N curve for fatigue characteristic evaluation.

  14. Evaluation of different screw fixation techniques and screw diameters in sagittal split ramus osteotomy: finite element analysis method.

    PubMed

    Sindel, A; Demiralp, S; Colok, G

    2014-09-01

    Sagittal split ramus osteotomy (SSRO) is used for correction of numerous congenital or acquired deformities in facial region. Several techniques have been developed and used to maintain fixation and stabilisation following SSRO application. In this study, the effects of the insertion formations of the bicortical different sized screws to the stresses generated by forces were studied. Three-dimensional finite elements analysis (FEA) and static linear analysis methods were used to investigate difference which would occur in terms of forces effecting onto the screws and transmitted to bone between different application areas. No significant difference was found between 1·5- and 2-mm screws used in SSRO fixation. Besides, it was found that 'inverted L' application was more successful compared to the others and that was followed by 'L' and 'linear' formations which showed close rates to each other. Few studies have investigated the effect of thickness and application areas of bicortical screws. This study was performed on both advanced and regressed jaws positions. © 2014 John Wiley & Sons Ltd.

  15. 21 CFR 882.5360 - Cranioplasty plate fastener.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... fastener. (a) Identification. A cranioplasty plate fastener is a screw, wire, or other article made of tantalum, vitallium, or stainless steel used to secure a plate to the patient's skull to repair a skull...

  16. 21 CFR 882.5360 - Cranioplasty plate fastener.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... fastener. (a) Identification. A cranioplasty plate fastener is a screw, wire, or other article made of tantalum, vitallium, or stainless steel used to secure a plate to the patient's skull to repair a skull...

  17. Complete Volumetric Decomposition of Individual Trabecular Plates and Rods and Its Morphological Correlations With Anisotropic Elastic Moduli in Human Trabecular Bone

    PubMed Central

    Liu, X Sherry; Sajda, Paul; Saha, Punam K; Wehrli, Felix W; Bevill, Grant; Keaveny, Tony M; Guo, X Edward

    2008-01-01

    Trabecular plates and rods are important microarchitectural features in determining mechanical properties of trabecular bone. A complete volumetric decomposition of individual trabecular plates and rods was used to assess the orientation and morphology of 71 human trabecular bone samples. The ITS-based morphological analyses better characterize microarchitecture and help predict anisotropic mechanical properties of trabecular bone. Introduction Standard morphological analyses of trabecular architecture lack explicit segmentations of individual trabecular plates and rods. In this study, a complete volumetric decomposition technique was developed to segment trabecular bone microstructure into individual plates and rods. Contributions of trabecular type–associated morphological parameters to the anisotropic elastic moduli of trabecular bone were studied. Materials and Methods Seventy-one human trabecular bone samples from the femoral neck (FN), tibia, and vertebral body (VB) were imaged using μCT or serial milling. Complete volumetric decomposition was applied to segment trabecular bone microstructure into individual plates and rods. The orientation of each individual trabecula was determined, and the axial bone volume fractions (aBV/TV), axially aligned bone volume fraction along each orthotropic axis, were correlated with the elastic moduli. The microstructural type–associated morphological parameters were derived and compared with standard morphological parameters. Their contributions to the anisotropic elastic moduli, calculated by finite element analysis (FEA), were evaluated and compared. Results The distribution of trabecular orientation suggested that longitudinal plates and transverse rods dominate at all three anatomic sites. aBV/TV along each axis, in general, showed a better correlation with the axial elastic modulus (r 2 = 0.95∼0.99) compared with BV/TV (r 2 = 0.93∼0.94). The plate-associated morphological parameters generally showed higher

  18. Complete volumetric decomposition of individual trabecular plates and rods and its morphological correlations with anisotropic elastic moduli in human trabecular bone.

    PubMed

    Liu, X Sherry; Sajda, Paul; Saha, Punam K; Wehrli, Felix W; Bevill, Grant; Keaveny, Tony M; Guo, X Edward

    2008-02-01

    Trabecular plates and rods are important microarchitectural features in determining mechanical properties of trabecular bone. A complete volumetric decomposition of individual trabecular plates and rods was used to assess the orientation and morphology of 71 human trabecular bone samples. The ITS-based morphological analyses better characterize microarchitecture and help predict anisotropic mechanical properties of trabecular bone. Standard morphological analyses of trabecular architecture lack explicit segmentations of individual trabecular plates and rods. In this study, a complete volumetric decomposition technique was developed to segment trabecular bone microstructure into individual plates and rods. Contributions of trabecular type-associated morphological parameters to the anisotropic elastic moduli of trabecular bone were studied. Seventy-one human trabecular bone samples from the femoral neck (FN), tibia, and vertebral body (VB) were imaged using muCT or serial milling. Complete volumetric decomposition was applied to segment trabecular bone microstructure into individual plates and rods. The orientation of each individual trabecula was determined, and the axial bone volume fractions (aBV/TV), axially aligned bone volume fraction along each orthotropic axis, were correlated with the elastic moduli. The microstructural type-associated morphological parameters were derived and compared with standard morphological parameters. Their contributions to the anisotropic elastic moduli, calculated by finite element analysis (FEA), were evaluated and compared. The distribution of trabecular orientation suggested that longitudinal plates and transverse rods dominate at all three anatomic sites. aBV/TV along each axis, in general, showed a better correlation with the axial elastic modulus (r(2) = 0.95 approximately 0.99) compared with BV/TV (r(2) = 0.93 approximately 0.94). The plate-associated morphological parameters generally showed higher correlations with the

  19. Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection.

    PubMed

    Helgeson, Melvin D; Kang, Daniel G; Lehman, Ronald A; Dmitriev, Anton E; Luhmann, Scott J

    2013-08-01

    There is currently no reliable technique for intraoperative assessment of pedicle screw fixation strength and optimal screw size. Several studies have evaluated pedicle screw insertional torque (IT) and its direct correlation with pullout strength. However, there is limited clinical application with pedicle screw IT as it must be measured during screw placement and rarely causes the spine surgeon to change screw size. To date, no study has evaluated tapping IT, which precedes screw insertion, and its ability to predict pedicle screw pullout strength. The objective of this study was to investigate tapping IT and its ability to predict pedicle screw pullout strength and optimal screw size. In vitro human cadaveric biomechanical analysis. Twenty fresh-frozen human cadaveric thoracic vertebral levels were prepared and dual-energy radiographic absorptiometry scanned for bone mineral density (BMD). All specimens were osteoporotic with a mean BMD of 0.60 ± 0.07 g/cm(2). Five specimens (n=10) were used to perform a pilot study, as there were no previously established values for optimal tapping IT. Each pedicle during the pilot study was measured using a digital caliper as well as computed tomography measurements, and the optimal screw size was determined to be equal to or the first size smaller than the pedicle diameter. The optimal tap size was then selected as the tap diameter 1 mm smaller than the optimal screw size. During optimal tap size insertion, all peak tapping IT values were found to be between 2 in-lbs and 3 in-lbs. Therefore, the threshold tapping IT value for optimal pedicle screw and tap size was determined to be 2.5 in-lbs, and a comparison tapping IT value of 1.5 in-lbs was selected. Next, 15 test specimens (n=30) were measured with digital calipers, probed, tapped, and instrumented using a paired comparison between the two threshold tapping IT values (Group 1: 1.5 in-lbs; Group 2: 2.5 in-lbs), randomly assigned to the left or right pedicle on each

  20. Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values.

    PubMed

    Smith, Nicole A; Turkyilmaz, Ilser

    2014-09-01

    When evaluating long-term implant success, clinicians have always been concerned with the gap at the implant-abutment junction, where bacteria can accumulate and cause marginal bone loss. However, little information regarding bacterial leakage at the implant-abutment junction, or microgap, is available. The purpose of this study was to evaluate sealing at 2 different implant-abutment interfaces under different screw torque values. Twenty sterile zirconia abutments and 20 sterile titanium abutments were screwed into 40 sterile implants and placed in test tubes. The ability of a bacterial mixture of Prevotella intermedia, Porphyromonas gingivalis, and Fusobacterium nucleatum to leak through an implant-titanium abutment seal under 20 and 35 Ncm torque values and an implant-zirconia abutment seal under 20 and 35 Ncm torque values was evaluated daily until leakage was noted. Once a unit demonstrated leakage, a specimen was plated. After 4 days, the number of colonies on each plate was counted with an electronic colony counter. Plating was used to verify whether or not bacterial leakage occurred and when leakage first occurred. The implant-abutment units were removed and rinsed with phosphate buffered saline solution and evaluated with a stereomicroscope. The marginal gap between the implant and the abutment was measured and correlated with the amount of bacterial leakage. The data were analyzed with ANOVA. Bacterial leakage was noted in all specimens, regardless of material or screw torque value. With titanium abutments, changing the screw torque value from 20 to 35 Ncm did not significantly affect the amount of bacterial leakage. However, with zirconia abutments, changing the screw torque value from 20 to 35 Ncm was statistically significant (P<.017). Overall, the marginal gap noted was larger at the zirconia-abutment interface (5.25 ±1.99 μm) than the titanium-abutment interface (12.38 ±3.73 μm), irrespective of the screw torque value. Stereomicroscopy revealed a

  1. Autotransplantation of Mandibular Third Molar with Buccal Cortical Plate to Replace Vertically Fractured Mandibular Second Molar: A Novel Technique.

    PubMed

    Zufía, Juan; Abella, Francesc; Trebol, Ivan; Gómez-Meda, Ramón

    2017-09-01

    Tooth replacement often leads to inadequate vertical volume in the recipient site bone when a tooth has been extracted because of a vertical root fracture (VRF). This case report presents the autotransplantation of a mandibular third molar (tooth #32) with the attached buccal cortical plate to replace a mandibular second molar (tooth #31) diagnosed with a VRF. After extraction of tooth #31, the recipient socket was prepared based on the size measured in advance with cone-beam computed tomographic imaging. The precise and calculated osteotomy of the cortical bone of tooth #32 allowed for the exact placement of the donor tooth in the position of tooth #31. The total extraoral time was only 25 minutes. The block was fixed to the recipient socket with an osteosynthesis screw and splinted with a double resin wire for 8 weeks. At the 6-month follow-up, the screw was removed, and the stability of the tooth and the regeneration obtained throughout the vestibular area were confirmed. At the 2-year follow-up, the transplanted tooth was asymptomatic and maintained a normal bone level. Advantages of autotransplantation over dental implants include maintenance of proprioception, possible orthodontic movements, and a relatively low cost. This case report demonstrates that an autotransplantation of a third molar attached to its buccal cortical plate is a viable option to replace teeth with a VRF. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Biomechanical properties of an advanced new carbon/flax/epoxy composite material for bone plate applications.

    PubMed

    Bagheri, Zahra S; El Sawi, Ihab; Schemitsch, Emil H; Zdero, Rad; Bougherara, Habiba

    2013-04-01

    This work is part of an ongoing program to develop a new carbon fiber/flax/epoxy (CF/flax/epoxy) hybrid composite material for use as an orthopaedic long bone fracture plate, instead of a metal plate. The purpose of this study was to evaluate the mechanical properties of this new novel composite material. The composite material had a "sandwich structure", in which two thin sheets of CF/epoxy were attached to each outer surface of the flax/epoxy core, which resulted in a unique structure compared to other composite plates for bone plate applications. Mechanical properties were determined using tension, three-point bending, and Rockwell hardness tests. Also, scanning electron microscopy (SEM) was used to characterize the failure mechanism of specimens in tension and three-point bending tests. The results of mechanical tests revealed a considerably high ultimate strength in both tension (399.8MPa) and flexural loading (510.6MPa), with a higher elastic modulus in bending tests (57.4GPa) compared to tension tests (41.7GPa). The composite material experienced brittle catastrophic failure in both tension and bending tests. The SEM images, consistent with brittle failure, showed mostly fiber breakage and fiber pull-out at the fractured surfaces with perfect bonding at carbon fibers and flax plies. Compared to clinically-used orthopaedic metal plates, current CF/flax/epoxy results were closer to human cortical bone, making the material a potential candidate for use in long bone fracture fixation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. [Unstable thorax fixation with bioabsorbable plates and screws. Presentation of some cases].

    PubMed

    Nolasco-de la Rosa, Ana Lilia; Mosiñoz-Montes, Roberto; Matehuala-García, Jesús; Román-Guzmán, Edgardo; Quero-Sandoval, Fidel; Reyes-Miranda, Alma Lorena

    2015-01-01

    Flail chest is managed with mechanical ventilation or inhalation therapy, and analgesia. Mechanical ventilations carry risks by themselves and disengage with the external fixators so they must be operated to improve lung ventilatory mechanics and cleaning. Little has been published on the use of bioabsorbable material and its evolution in the setting of flail chest. A material that did had to be retired, that presented the malleability of titanium and its inflammatory reaction was minimal and could be handled in both adults and children was investigated. Here is shown a descriptive study of patients with flail chest under rib fixation with plates and bioabsorbable screws. 18 cases are presented, aged 33-74 years, three with bilateral flail chest; fixation was performed between days 1-21 of the accident. In cases that showed no fractures pelvic limbs, gait next day restarted fi ng in all cases improved mechanical ventilation, pain decreased, none has so far presented reaction material. Flail chest has a high (16.3%) mortality when no management provides the pathophysiology of the condition (pain, poor mechanical ventilation, alveolar edema-pulmonary contusion). The use of bioabsorbable material has no side effects attributable to material which is another option for rib fixation. Copyright © 2015. Published by Masson Doyma México S.A.

  4. Histomorphometric Evaluation of the Effects of Various Diode Lasers and Force Levels on Orthodontic Mini Screw Stability

    PubMed Central

    Isman, Eren; Taner, Lale; Kurkcu, Mehmet

    2015-01-01

    Abstract Objective The purpose of this study was to evaluate the effects of different laser dose and force levels on the stability of orthodontic mini screws used for anchorage, by histomorphometric analyses. Background data Low-level laser therapy speeds up blood flow, improves the mechanism of the revitalization processes, reduces the risk of infection, boosts metabolic activities, and accelerates the healing of the damaged tissue. Although there are many research studies about low-level laser therapy applications in a variety of areas, no investigations were found concerning mini screw stability using various laser dose levels with different force level applications. Methods Seventeen New Zealand white rabbits were used. A total of 68 cylindrical, self-drilling orthodontic mini screws were threaded at the fibula. Experimental subjects were divided into six groups; force application was not performed in the first three groups, whereas 150g of force was applied via nickel-titanium closed-coil springs placed between two mini screws in the other three groups. Measurements of the initial torque values (10 Ncm) were manipulated by a digital portable torque gauge. Various low-level laser doses were applied to the groups during the postoperative 10 days. After 4 weeks, bone-to-implant contact and cortical bone thickness were histomorphometrically analyzed. Results In the 150g force plus 20 J/cm2 dosage group, the highest bone-to-implant contact values were observed. (p<0.05) There were no statistically significant correlations between cortical bone thickness and bone-to-implant contact values; on the other hand, no significant difference was found among the same groups in terms of cortical bone thickness values (p>0.05). Conclusions Low-level laser therapy was noticed to induce the mini screw–bone contact area. Low-level laser therapy may be a supplementary treatment method to increase the stability of the orthodontic mini screw. PMID:25594769

  5. Subchondral chitosan/blood implant-guided bone plate resorption and woven bone repair is coupled to hyaline cartilage regeneration from microdrill holes in aged rabbit knees.

    PubMed

    Guzmán-Morales, J; Lafantaisie-Favreau, C-H; Chen, G; Hoemann, C D

    2014-02-01

    Little is known of how to routinely elicit hyaline cartilage repair tissue in middle-aged patients. We tested the hypothesis that in skeletally aged rabbit knees, microdrill holes can be stimulated to remodel the bone plate and induce a more integrated, voluminous and hyaline cartilage repair tissue when treated by subchondral chitosan/blood implants. New Zealand White rabbits (13 or 32 months old, N = 7) received two 1.5 mm diameter, 2 mm depth drill holes in each knee, either left to bleed as surgical controls or press-fit with a 10 kDa (distal hole: 10K) or 40 kDa (proximal hole: 40K) chitosan/blood implant with fluorescent chitosan tracer. Post-operative knee effusion was documented. Repair tissues at day 0 (N = 1) and day 70 post-surgery (N = 6) were analyzed by micro-computed tomography, and by histological scoring and histomorphometry (SafO, Col-2, and Col-1) at day 70. All chitosan implants were completely cleared after 70 days, without increasing transient post-operative knee effusion compared to controls. Proximal control holes had worse osteochondral repair than distal holes. Both implant formulations induced bone remodeling and improved lateral integration of the bone plate at the hole edge. The 40K implant inhibited further bone repair inside 50% of the proximal holes, while the 10K implant specifically induced a "wound bloom" reaction, characterized by decreased bone plate density in a limited zone beyond the initial hole edge, and increased woven bone (WB) plate repair inside the initial hole (P = 0.016), which was accompanied by a more voluminous and hyaline cartilage repair (P < 0.05 vs control defects). In a challenging aged rabbit model, bone marrow-derived hyaline cartilage repair can be promoted by treating acute drill holes with a biodegradable subchondral implant that elicits bone plate resorption followed by anabolic WB repair within a 70-day repair period. Copyright © 2013 Osteoarthritis Research Society International. Published by

  6. Prevention of Proximal Junctional Kyphosis: Are Polyaxial Pedicle Screws Superior to Monoaxial Pedicle Screws at the Upper Instrumented Vertebrae?

    PubMed

    Wang, Hui; Ding, Wenyuan; Ma, Lei; Zhang, Lijun; Yang, Dalong

    2017-05-01

    Evidence regarding whether the polyaxial pedicle screws at the upper instrumented vertebrae (UIV) are superior to monoaxial pedicle screws in prevention of proximal junctional kyphosis (PJK) is not clear. The aim of this study was therefore to explore the influence of different types of pedicle screws at UIV on the incidence of PJK. We reviewed retrospectively 242 patients surgically treated with instrumented segmental posterior spinal fusion at a minimum of 4 motion segments. Polyaxial pedicle screws were used at UIV in 125 patients (polyaxial group), and monoaxial pedicle screws were used at UIV in 117 patients (monoaxial group). According to the occurrence of PJK at final follow-up, patients in both the polyaxial and monoaxial groups were then divided into 2 subgroups: PJK and no proximal junctional kyphosis (NPJK). To investigate the risk factors of PJK, 2 categorized variables were analyzed statistically: 1) patient characteristics: age, sex, body mass index (BMI), bone mineral density (BMD), sagittal vertical axis (SVA), thoracic kyphosis, thoracolumbar junctional angle, lumbar lordosis (LL), pelvic incidence, pelvic tilt, and sacral slope. 2) Surgical variables: Changes of radiographic parameters include the SVA, thoracic kyphosis, thoracolumbar junctional, LL, pelvic incidence, pelvic tilt, sacral slope, pedicle-upper end plate angle, the number of instrumented levels, and the most proximal and distal levels of the instrumentation. PJK was developed in 26 of 117 patients (22.2%) in the monoaxial group and 30 of 125 patients (24.0%) in the polyaxial group. Until the final follow-up, there was no significant difference in the incidence of PJK (χ2 = 0.107, P = 0.734) between the monoaxial and polyaxial groups. There was no significant difference in patient characteristics and surgical variables between the 2 groups, except the proximal junctional angle change (P = 0.031). In the monoaxial group, there were no significant differences in patient

  7. Tibial plateau fracture after anterior cruciate ligament reconstruction: Role of the interference screw resorption in the stress riser effect.

    PubMed

    Thaunat, Mathieu; Nourissat, Geoffroy; Gaudin, Pascal; Beaufils, Philippe

    2006-06-01

    We report a case of tibial plateau fracture after previous anterior cruciate ligament (ACL) reconstruction using patellar tendon autograft and bioabsorbable screws 4 years previously. The fracture occurred through the tibial tunnel. The interference screw had undergone complete resorption and the tunnel widening had increased. The resorption of the interference screw did not simultaneously promote and foster the growth of surrounding bone tissue. Therefore, the area of reactive tissue left by the screw resorption in an enlarged bone tunnel may lead to vulnerability of the tibial plateau. Stress risers would occur following ACL reconstruction if either resorption is not complete or bony integration is not complete.

  8. BIOMECHANICAL EVALUATION OF THE INFLUENCE OF CERVICAL SCREWS TAPPING AND DESIGN.

    PubMed

    Silva, Patricia; Rosa, Rodrigo César; Shimano, Antonio Carlos; Albuquerque de Paula, Francisco José; Volpon, José Batista; Aparecido Defino, Helton Luiz

    2009-01-01

    To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were the insertion torque and pullout strength. The following groups were created: Group I-self-tapping screw insertion after pilot hole drilling and tapping; Group II-self-tapping screw insertion after pilot hole drilling without tapping; Group III-self-drilling screw insertion without drilling and tapping. In Groups I and II, the pilot hole had 14.0 mm in depth and was made with a 3mmn drill, while tapping was made with a 4mm tap. The insertion torque was measured and the pullout test was performed. The comparison between groups was made considering the mean insertion torque and the maximum mean pullout strength with the variance analysis (ANOVA; p≤ 0.05). Previous drilling and tapping of pilot hole significantly decreased the insertion torque and the pullout strength. The insertion torque and pullout strength of self-drilling screws were significantly higher when compared to self-tapping screws inserted after pilot hole tapping.

  9. Accelerated Growth Plate Mineralization and Foreshortened Proximal Limb Bones in Fetuin-A Knockout Mice

    PubMed Central

    Gupta, Himadri S.; Schäfer, Cora; Krauss, Stefanie; Dunlop, John W. C.; Masic, Admir; Kerschnitzki, Michael; Zaslansky, Paul; Boesecke, Peter; Catalá-Lehnen, Philip; Schinke, Thorsten; Fratzl, Peter; Jahnen-Dechent, Willi

    2012-01-01

    The plasma protein fetuin-A/alpha2-HS-glycoprotein (genetic symbol Ahsg) is a systemic inhibitor of extraskeletal mineralization, which is best underscored by the excessive mineral deposition found in various tissues of fetuin-A deficient mice on the calcification-prone genetic background DBA/2. Fetuin-A is known to accumulate in the bone matrix thus an effect of fetuin-A on skeletal mineralization is expected. We examined the bones of fetuin-A deficient mice maintained on a C57BL/6 genetic background to avoid bone disease secondary to renal calcification. Here, we show that fetuin-A deficient mice display normal trabecular bone mass in the spine, but increased cortical thickness in the femur. Bone material properties, as well as mineral and collagen characteristics of cortical bone were unaffected by the absence of fetuin-A. In contrast, the long bones especially proximal limb bones were severely stunted in fetuin-A deficient mice compared to wildtype littermates, resulting in increased biomechanical stability of fetuin-A deficient femora in three-point-bending tests. Elevated backscattered electron signal intensities reflected an increased mineral content in the growth plates of fetuin-A deficient long bones, corroborating its physiological role as an inhibitor of excessive mineralization in the growth plate cartilage matrix - a site of vigorous physiological mineralization. We show that in the case of fetuin-A deficiency, active mineralization inhibition is a necessity for proper long bone growth. PMID:23091616

  10. Significance of the Pars Interarticularis in the Cortical Bone Trajectory Screw Technique: An In Vivo Insertional Torque Study.

    PubMed

    Ninomiya, Koshi; Iwatsuki, Koichi; Ohnishi, Yu-Ichiro; Ohkawa, Toshika; Yoshimine, Toshiki

    2016-10-01

    Retrospective study. Cortical bone trajectory (CBT), a more medial-to-lateral and shorter path than the traditional one for spinal fusion, is thought to be effective for severely degenerated vertebrae because screws are primarily stabilized at the posterior elements. We evaluated the efficacy of this approach through in vivo insertional torque measurement. There has been only one prior in vivo study on CBT insertional torque. Between January 2013 and April 2014, a total of 22 patients underwent posterior lumbar fusion using the CBT technique. The maximum insertional torque, which covers the radial strength needed for insertion, was measured for 113 screws, 8 of which were inserted for L5 spondylolysis. The insertional torque for cases with (n=8) and without (n=31) spondylolysis of L5 were compared using one-way analysis of variance (ANOVA). To evaluate vertebral degeneration, we classified 53 vertebrae without spondylolysis by lumbar radiography using semiquantitative methods; the insertional torque for the 105 screws used was compared on the basis of this classification. Additionally, differences in insertional torque among cases grouped by age, sex, and lumbar level were evaluated for these 105 screws using ANOVA and the Tukey test. The mean insertional torque was significantly lower for patients with spondylolysis than for those without spondylolysis (4.25 vs. 8.24 in-lb). There were no statistical differences in insertional torque according to vertebral grading or level. The only significant difference in insertional torque between age and sex groups was in men <75 years and women ≥75 years (10 vs. 5.5 in-lb). Although CBT should be used with great caution in patient with lysis who are ≥75 years, it is well suited for dealing with severely degenerated vertebrae because the pars interarticularis plays a very important role in the implementation of this technique.

  11. Stress distribution pattern of screw-retained restorations with segmented vs. non-segmented abutments: A finite element analysis

    PubMed Central

    Aalaei, Shima; Rajabi Naraki, Zahra; Nematollahi, Fatemeh; Beyabanaki, Elaheh; Shahrokhi Rad, Afsaneh

    2017-01-01

    Background. Screw-retained restorations are favored in some clinical situations such as limited inter-occlusal spaces. This study was designed to compare stresses developed in the peri-implant bone in two different types of screw-retained restorations (segmented vs. non-segmented abutment) using a finite element model. Methods. An implant, 4.1 mm in diameter and 10 mm in length, was placed in the first molar site of a mandibular model with 1 mm of cortical bone on the buccal and lingual sides. Segmented and non-segmented screw abutments with their crowns were placed on the simulated implant in each model. After loading (100 N, axial and 45° non-axial), von Mises stress was recorded using ANSYS software, version 12.0.1. Results. The maximum stresses in the non-segmented abutment screw were less than those of segmented abutment (87 vs. 100, and 375 vs. 430 MPa under axial and non-axial loading, respectively). The maximum stresses in the peri-implant bone for the model with segmented abutment were less than those of non-segmented ones (21 vs. 24 MPa, and 31 vs. 126 MPa under vertical and angular loading, respectively). In addition, the micro-strain of peri-implant bone for the segmented abutment restoration was less than that of non-segmented abutment. Conclusion. Under axial and non-axial loadings, non-segmented abutment showed less stress concentration in the screw, while there was less stress and strain in the peri-implant bone in the segmented abutment. PMID:29184629

  12. Experimental models for cancellous bone healing in the rat

    PubMed Central

    Bernhardsson, Magnus; Sandberg, Olof; Aspenberg, Per

    2015-01-01

    Background and purpose — Cancellous bone appears to heal by mechanisms different from shaft fracture healing. There is a paucity of animal models for fractures in cancellous bone, especially with mechanical evaluation. One proposed model consists of a screw in the proximal tibia of rodents, evaluated by pull-out testing. We evaluated this model in rats by comparing it to the healing of empty drill holes, in order to explain its relevance for fracture healing in cancellous bone. To determine the sensitivity to external influences, we also compared the response to drugs that influence bone healing. Methods — Mechanical fixation of the screws was measured by pull-out test and related to the density of the new bone formed around similar, but radiolucent, PMMA screws. The pull-out force was also related to the bone density in drill holes at various time points, as measured by microCT. Results — The initial bone formation was similar in drill holes and around the screw, and appeared to be reflected by the pull-out force. Both models responded similarly to alendronate or teriparatide (PTH). Later, the models became different as the bone that initially filled the drill hole was resorbed to restore the bone marrow cavity, whereas on the implant surface a thin layer of bone remained, making it change gradually from a trauma-related model to an implant fixation model. Interpretation — The similar initial bone formation in the different models suggests that pull-out testing in the screw model is relevant for assessment of metaphyseal bone healing. The subsequent remodeling would not be of clinical relevance in either model. PMID:26200395

  13. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    PubMed Central

    Bemelman, Michael; van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has become available suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation. PMID:26889439

  14. Hox11 genes regulate postnatal longitudinal bone growth and growth plate proliferation.

    PubMed

    Pineault, Kyriel M; Swinehart, Ilea T; Garthus, Kayla N; Ho, Edward; Yao, Qing; Schipani, Ernestina; Kozloff, Kenneth M; Wellik, Deneen M

    2015-10-23

    Hox genes are critical regulators of skeletal development and Hox9-13 paralogs, specifically, are necessary for appendicular development along the proximal to distal axis. Loss of function of both Hoxa11 and Hoxd11 results in severe malformation of the forelimb zeugopod. In the radius and ulna of these mutants, chondrocyte development is perturbed, growth plates are not established, and skeletal growth and maturation fails. In compound mutants in which one of the four Hox11 alleles remains wild-type, establishment of a growth plate is preserved and embryos develop normally through newborn stages, however, skeletal phenotypes become evident postnatally. During postnatal development, the radial and ulnar growth rate slows compared to wild-type controls and terminal bone length is reduced. Growth plate height is decreased in mutants and premature growth plate senescence occurs along with abnormally high levels of chondrocyte proliferation in the reserve and proliferative zones. Compound mutants additionally develop an abnormal curvature of the radius, which causes significant distortion of the carpal elements. The progressive bowing of the radius appears to result from physical constraint caused by the disproportionately slower growth of the ulna than the radius. Collectively, these data are consistent with premature depletion of forelimb zeugopod progenitor cells in the growth plate of Hox11 compound mutants, and demonstrate a continued function for Hox genes in postnatal bone growth and patterning. © 2015. Published by The Company of Biologists Ltd.

  15. Histomorphologic findings on human bone samples six months after bone augmentation of the maxillary sinus with Algipore.

    PubMed

    Schopper, C; Moser, D; Wanschitz, F; Watzinger, F; Lagogiannis, G; Spassova, E; Ewers, R

    1999-01-01

    Sinus grafting, a popular and standard treatment for maxillary atrophy, uses a variety of grafting materials. In this study, specimens obtained 6 months after sinus grafting with Algipore were evaluated under light microscopy and showed osseoformation, xenograft degradation, and bone ingrowth into particles. Osteoblastic cells were embedded in the intracorpuscular bone matrix, which indicated that xenograft particles are an osseoconductive scaffold and stimulate matrix deposition. Acute inflammatory responses after insertion of Algipore did not occur. Particles were degraded during physiologic bone remodeling, and newly formed bone gradually replaced resorbed biomaterial.

  16. The effect of external coaptation on plate deformation in an ex vivo model of canine pancarpal arthrodesis.

    PubMed

    Woods, S; Wallace, R J; Mosley, J R

    2012-01-01

    Since external coaptation is applied clinically to prevent plate failure during healing in canine pancarpal arthrodesis (PCA), we tested the hypothesis that external coaptation does not significantly reduce plate strain in an experimental ex vivo model of canine PCA. Ten thoracic limbs from healthy Greyhounds euthanatized for reasons un- related to the study were harvested and the carpus was stabilised with a dorsally applied 2.7/3.5 mm hybrid PCA plate. The strain in the plate adjacent to the most distal radial screw hole (R4) and the radial carpal bone (RCB) screw hole was measured as the limbs were loaded axially to a load that approximated that of controlled walking. Each limb was tested with and without external coaptation in place. Mean strain amplitude at the RCB was -177.2 με (± 20.78) without external coaptation. Following cast application, strain reduced significantly to -34.7 με (± 9.84) (p <0.002). Mean strain at R4 was -89.4 με (± 22.10) without external support and -66.9 με (± 10.74) following application of a cast. This reduction in recorded strain was not statistically significant. The application of a cast to the distal portion of the limb significantly reduced strain in the 2.7/3.5 mm hybrid PCA plate, but the magnitude of the measured strain was low, suggesting that fatigue damage is unlikely to accumulate as a result of this type of loading and that external coaptation may not be necessary to prevent fatigue failure of the plate.

  17. Influence of Diamondlike Carbon Coating of Screws on Axial Tightening Force and Stress Distribution on Overdenture Bar Frameworks with Different Fit Levels and Materials.

    PubMed

    dos Santos, Mateus Bertolini Fernandes; Bacchi, Atais; Consani, Rafael Leonardo Xediek; Correr-Sobrinho, Lourenço

    2015-01-01

    The aim of this study was to evaluate the axial tightening force applied by conventional and diamondlike carbon (DLC)-coated screws and to verify, through three-dimensional finite element analysis (FEA), the stress distribution caused by different framework materials and prosthetic screws in overdenture frameworks with different misfit levels. The axial tightening force applied by the screw was evaluated by means of a titanium matrix connected to a load cell. Conventional titanium or DLC-coated screws were tightened with a digital torque wrench, and the load values were recorded. The values were applied in an FEA to a bar-clip attachment system connected to two 4.0 × 11-mm external-hexagon titanium implants placed in an anterior edentulous arch. DLC-coated and conventional screws were modeled with their respective axial forces obtained on the experimental evaluation for three bar framework materials (titanium, nickel-chromium, and cobalt-chromium) and three levels of misfit (100, 150, and 200 μm). Von Mises stresses for prosthetic components and maximum principal stress and microstrains (maximum principal strains) for bone tissue were measured. The mean force applied by the conventional screw was 25.55 N (± 1.78); the prosthetic screw coated with a DLC layer applied a mean force of 31.44 N (± 2.11), a statistically significant difference. In the FEA, the DLC screw led to higher stresses on the framework; however, the prosthetic screw suffered lower stress. No influence of screw type was seen in the bone tissue. Titanium frameworks reduced the stress transmitted to the bone tissue and the bar framework but had no influence on the screws. Higher misfit values resulted in an increased stress/strain in bone tissue and bar framework, which was not the case for retention screws.

  18. Osteosynthesis using plates and screws after removing a limited area of the periosteum in order to reduce misclassified during radiological assessment metacarpal shaft fractures

    PubMed Central

    Neagu, TP; Popescu, SA; Cobilinschi, C; Tincu, R; Tiglis, M; Lascar, I

    2016-01-01

    Hand fractures are one of the most common causes for presenting to the emergency room. Metacarpal fractures count about 18 to 44% of all hand fractures, and are most often standalone closed injuries, without misplacement, not needing operative treatment. We present a case in which osteosynthesis with plates and screws was used to reduce two metacarpal fractures in order to allow an early motion recovery, despite the fact that a small portion of the periosteum needed to be removed. The type of fractures were misclassified according to the radiological findings, therefore the correct diagnosis was established during surgery. The results according to the radiological aspects and to the DASH score were excellent with 95% function recovery at twelve months. In this case, the use of osteosynthesis with plates and screws led to a good fracture healing without any major complications. However, there are a series of complications related to this method that should be taken into consideration. Being misled by the radiological aspects of the fractures, the most certain way to classify a metacarpal shaft fracture is through exploratory surgery, even if in most of the cases the three radiological views are enough to establish the diagnosis. Abbreviations: DASH score = Disability of Arm, Shoulder and Hand score, TAM = Total Active Motion, MCP = metacarpal phalangeal joint, PIP = proximal inter phalangeal joint PMID:27974942

  19. Fixation of fractures of the condylar head of the mandible with a new magnesium-alloy biodegradable cannulated headless bone screw.

    PubMed

    Leonhardt, H; Franke, A; McLeod, N M H; Lauer, G; Nowak, A

    2017-07-01

    It is difficult to fix fractures of the condylar head of the mandible. Several techniques have been described which show satisfactory outcomes, but stability can be questionable, and some can cause irritation of the soft tissues. We describe a technique and first results of treating such fractures with resorbable magnesium-based headless bone screws (Magnezix ® 2.7mm CS; Syntellix AG, Hanover, Germany). Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Plate fixation and bone grafting of distal clavicle nonunions: radiologic and functional outcomes.

    PubMed

    Villa, Jordan C; van der List, Jelle P; Gausden, Elizabeth B; Lorich, Dean G; Helfet, David L; Kloen, Peter; Wellman, David S

    2016-11-01

    The optimal treatment for distal clavicle nonunions remains unknown. Small series have reported outcomes following distal fragment excision and various fixation techniques. We present the clinical, radiographic and functional outcomes after superior plating or double (superior and anteroinferior) plating in combination with bone grafting as treatment for distal clavicle nonunions. We collected demographic and radiographic data from a consecutive series of ten patients with symptomatic nonunion of the distal clavicle treated since 1998. Functional outcomes were assessed, as well as the visual analogue scale (VAS) score. The mean clinical follow-up was 41.4 months (range of 12-158 months). The mean radiological follow-up was 30.6 months (range of 3-158 months). All nonunions healed as demonstrated by subsidence of clinical symptoms and radiographic criteria. The average time to union was 3.7 months (range of 2-8 months). The mean The Disabilities of the Arm, Shoulder and Hand (DASH) score was 11.9 (range of 0-62.5) and mean VAS score was 0.9 at follow-up. This study illustrates good clinical, radiologic and functional outcomes in ten patients with distal clavicle nonunion treated with superior or double (superior and anteroinferior) plating in combination with bone grafting. Double-plating can be considered an alternative to superior plating offering better resistance against the pulling effect of the arm with the use of smaller fixation plates.

  1. The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?

    PubMed

    Paik, Haines; Kang, Daniel G; Lehman, Ronald A; Gaume, Rachel E; Ambati, Divya V; Dmitriev, Anton E

    2013-11-01

    Rod contouring is frequently required to allow for appropriate alignment of pedicle screw-rod constructs. When residual mismatch is still present, a rod persuasion device is often used to achieve further rod reduction. Despite its popularity and widespread use, the biomechanical consequences of this technique have not been evaluated. To evaluate the biomechanical fixation strength of pedicle screws after attempted reduction of a rod-pedicle screw mismatch using a rod persuasion device. Fifteen 3-level, human cadaveric thoracic specimens were prepared and scanned for bone mineral density. Osteoporotic (n=6) and normal (n=9) specimens were instrumented with 5.0-mm-diameter pedicle screws; for each pair of comparison level tested, the bilateral screws were equal in length, and the screw length was determined by the thoracic level and size of the vertebra (35 to 45 mm). Titanium 5.5-mm rods were contoured and secured to the pedicle screws at the proximal and distal levels. For the middle segment, the rod on the right side was intentionally contoured to create a 5-mm residual gap between the inner bushing of the pedicle screw and the rod. A rod persuasion device was then used to engage the setscrew. The left side served as a control with perfect screw/rod alignment. After 30 minutes, constructs were disassembled and vertebrae individually potted. The implants were pulled in-line with the screw axis with peak pullout strength (POS) measured in Newton (N). For the proximal and distal segments, pedicle screws on the right side were taken out and reinserted through the same trajectory to simulate screw depth adjustment as an alternative to rod reduction. Pedicle screws reduced to the rod generated a 48% lower mean POS (495±379 N) relative to the controls (954±237 N) (p<.05) and significantly decreased work energy to failure (p<.05). Nearly half (n=7) of the pedicle screws had failed during the reduction attempt with visible pullout of the screw. After reduction, decreased

  2. Biomechanical comparison of locked versus non-locked symphyseal plating of unstable pelvic ring injuries.

    PubMed

    Godinsky, R J; Vrabec, G A; Guseila, L M; Filipkowski, D E; Elias, J J

    2018-04-01

    Locked symphyseal plates are utilized to provide higher levels of construct stiffness than non-locked plates. The current biomechanical study was performed to compare stiffness at the pubic symphysis between locked and non-locked plating systems. Synthetic models were utilized to represent injury to the pelvis and symphyseal plating combined with a sacro-iliac screw. Seven models were evaluated with plates and locking screws, and seven were evaluated with non-locking screws. Single limb stance was simulated, with all models loaded for 1000 cycles with 350 N applied at the sacrum. Two pairs of markers crossing the symphysis were tracked with a video-based tracking system. A coordinate system was developed to quantify motion between the pairs in three directions: medial-lateral gap, anterior-posterior shear translation, and superior-inferior shear translation. Significant differences between the plating systems were identified with t tests (p < 0.05). Anterior-posterior shear translation varied significantly between the two plating systems. From cycles 100 to 1000, average shear translation for the non-locked and locked systems was ~0.7 and 0.3 mm, respectively, at the markers closest to the plate and 2.2 and 1.4 mm, respectively, at the markers further from the plate. Motion in the other two directions did not differ significantly between locked and non-locked models. Locked symphyseal plating systems can provide better stability than non-locked systems for anterior-posterior shear translation. More stability could potentially reduce the risk of failure of the plate or screws.

  3. Use of intramedullary fibular strut graft: a novel adjunct to plating in the treatment of osteoporotic humeral shaft nonunion

    PubMed Central

    Vamsi, K.; Rao, Sharath K.; Gnanadoss, James J.; Pandian, S.

    2008-01-01

    Humeral shaft fractures respond well to conservative treatment and unite without much problem. Since it is uncommon, there is not much discussion regarding the management of nonunion in the literature, and hence this is a challenge to the treating orthopaedic surgeon. Osteoporosis of the fractured bone and stiffness of the surrounding joints compounds the situation further. The Ilizarov fixator, locking compression plate, and vascularised fibular graft are viable options in this scenario but are technically demanding. We used a fibular strut graft for bridging the fracture site in order to enhance the pull-out strength of the screws of the dynamic compression plate. Six patients in the study had successful uneventful union of the fracture at the last follow-up. The fibula is easy to harvest and produces less graft site morbidity. None of the study patients needed additional iliac crest bone grafting. This is the largest reported series of patients with osteoporotic atrophic nonunion of humerus successfully treated solely using the combination of an intramedullary fibular strut graft and dynamic compression plate. PMID:18563410

  4. [Augmentation technique on the proximal humerus].

    PubMed

    Scola, A; Gebhard, F; Röderer, G

    2015-09-01

    The treatment of osteoporotic fractures is still a challenge. The advantages of augmentation with respect to primary in vitro stability and the clinical use for the proximal humerus are presented in this article. In this study six paired human humeri were randomized into an augmented and a non-augmented group. Osteosynthesis was performed with a PHILOS plate (Synthes®). In the augmented group the two screws finding purchase in the weakest cancellous bone were augmented. The specimens were tested in a 3-part fracture model in a varus bending test. The augmented PHILOS plates withstood significantly more load cycles until failure. The correlation to bone mineral density (BMD) showed that augmentation could partially compensate for low BMD. The augmentation of the screws in locked plating in a proximal humerus fracture model is effective in improving the primary stability in a cyclic varus bending test. The targeted augmentation of two particular screws in a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality could be more effective in enhancing the primary stability of a proximal humerus locking plate because the effect of augmentation can be exploited more effectively limiting it to the degree required. The technique of augmentation is simple and can be applied in open and minimally invasive procedures. When the correct procedure is used, complications (cement leakage into the joint) can be avoided.

  5. [Use of four kinds of three-dimensional printing guide plate in bone tumor resection and reconstruction operation].

    PubMed

    Fu, Jun; Guo, Zheng; Wang, Zhen; Li, Xiangdong; Fan, Hongbin; Li, Jing; Pei, Yanjun; Pei, Guoxian; Li, Dan

    2014-03-01

    To explore the effectiveness of excision and reconstruction of bone tumor by using operation guide plate made by variety of three-dimensional (3-D) printing techniques, and to compare the advantages and disadvantages of different 3-D printing techniques in the manufacture and application of operation guide plate. Between September 2012 and January 2014, 31 patients with bone tumor underwent excision and reconstruction of bone tumor by using operation guide plate. There were 19 males and 12 females, aged 6-67 years (median, 23 years). The disease duration ranged from 15 days to 12 months (median, 2 months). There were 13 cases of malignant tumor and 18 cases of benign tumor. The tumor located in the femur (9 cases), the spine (7 cases), the tibia (6 cases), the pelvis (5 cases), the humerus (3 cases), and the fibula (1 case). Four kinds of 3-D printing technique were used in processing operation guide plate: fused deposition modeling (FDM) in 9 cases, stereo lithography appearance (SLA) in 14 cases, 3-D printing technique in 5 cases, and selective laser sintering (SLS) in 3 cases; the materials included ABS resin, photosensitive resin, plaster, and aluminum alloy, respectively. Before operation, all patients underwent thin layer CT scanning (0.625 mm) in addition to conventional imaging. The data were collected for tumor resection design, and operation guide plate was designed on the basis of excision plan. Preoperatively, the operation guide plates were made by 3-D printing equipment. After sterilization, the guide plates were used for excision and reconstruction of bone tumor. The time of plates processing cycle was recorded to analyse the efficiency of 4 kinds of 3-D printing techniques. The time for design and operation and intraoperative fluoroscopy frequency were recorded. Twenty-eight patients underwent similar operations during the same period as the control group. The processing time of operation guide plate was (19.3 +/- 6.5) hours in FDM, (5.2 +/- 1

  6. Biomechanical comparison of straight and helical compression plates for fixation of transverse and oblique bone fractures: Modeling and experiments.

    PubMed

    Sezek, Sinan; Aksakal, Bunyamin; Gürger, Murat; Malkoc, Melih; Say, Y

    2016-08-12

    Total deformation and stability of straight and helical compression plates were studied by means of the finite element method (FEM) and in vitro biomechanical experiments. Fixations of transverse (TF) and oblique (45°) bone (OF) fractures have been analyzed on sheep tibias by designing the straight compression (SP) and Helical Compression Plate (HP) models. The effects of axial compression, bending and torsion loads on both plating systems were analyzed in terms of total displacements. Numerical models and experimental models suggested that under compression loadings, bone fracture gap closures for both fracture types were found to be in the favor of helical plate designs. The helical plate (HP) fixations provided maximum torsional resistance compared to the (SP) fixations. The fracture gap closure and stability of helical plate fixation for transverse fractures was determined to be higher than that found for the oblique fractures. The comparison of average compression stress, bending and torsion moments showed that the FEM and experimental results are in good agreement and such designs are likely to have a positive impact in future bone fracture fixation designs.

  7. The accuracy and safety of fluoroscopically guided percutaneous pedicle screws in the lumbosacral junction and the lumbar spine: a review of 880 screws.

    PubMed

    Chiu, C K; Kwan, M K; Chan, C Y W; Schaefer, C; Hansen-Algenstaedt, N

    2015-08-01

    We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. ©2015 The British Editorial Society of Bone & Joint Surgery.

  8. "Turn-of-the-Nut" Method Is Not Appropriate for Use in Cancellous Bone.

    PubMed

    Ryan, Melissa K; Mohtar, Aaron A; Costi, John J; Reynolds, Karen J

    2015-11-01

    The level to which bone screws are tightened is determined subjectively by the operating surgeon. It is likely that the tactile feedback that surgeons rely on is based on localized tissue yielding, which may predispose the screw-bone interface to failure. A limited number of studies have investigated the ratio between clinical tightening torque and stripping torque. The purpose of this study was to measure, for the first time, the ratio between yield torque (T yield) and stripping torque (T max) during screw insertion into the cancellous bone and to compare these torques with clinical levels of tightening reported in the literature. Additionally, a rotational limit was investigated as a potential end point for screw insertion in cancellous bone. A 6.5-mm outer diameter commercial cancellous bone screw was inserted into human femoral head specimens (n = 89). Screws were inserted to failure, while recording insertion torque, compression under the screw head, and rotation angle. The median, interquartile ranges, and coefficient of variation were calculated for each of the following parameters: T yield, T max, T yield/T max, slope, T plateau, and rotation angle. The median ratio of T yield/T max and rotation angle was 85.45% and 96.5 degrees, respectively. The coefficient of variation was greatest for the rotation angle compared with the ratio of T yield/T max (0.37 vs. 0.12). The detection of yield may be a more precise method than the rotation angle in cancellous bone; however, bone-screw constructs that exhibit a T yield close to T max may be more susceptible to stripping during insertion. Future work can identify factors that influence the ratio of T yield/T max may help to reduce the incidence of screw stripping.

  9. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study

    PubMed Central

    Bali, Rishi K.; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-01-01

    Aims: The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. Materials and Methods: This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inion CPS) using standard plating principles and observed for a total period of 24 weeks. Characteristics of the fractures, ease of use of bioresorbable plate/screw system and post operative complications were assessed. Results: Of total 10 patients, eight patients were of midface fracture and two pediatric patients with mandibular fracture, with nine male and one female. The mean age was 32.8 years. Out of 20 plates and 68 screws applied to the 10 fractures sites; there were three incidences of screw breakage with no other intraoperative difficulties. Paresthesia of the infraorbital nerve was present in two patients, and recovered completely in four weeks after surgery. Fracture reduction was considered to be satisfactory in all cases. One patient developed postsurgical infection and was managed with oral antibiotics and analgesics. Conclusions: Favorable healing can be observed through the use of biodegradable plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood, however further studies with more sample size are required. PMID:24665170

  10. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study.

    PubMed

    Bali, Rishi K; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-07-01

    The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inion CPS) using standard plating principles and observed for a total period of 24 weeks. Characteristics of the fractures, ease of use of bioresorbable plate/screw system and post operative complications were assessed. Of total 10 patients, eight patients were of midface fracture and two pediatric patients with mandibular fracture, with nine male and one female. The mean age was 32.8 years. Out of 20 plates and 68 screws applied to the 10 fractures sites; there were three incidences of screw breakage with no other intraoperative difficulties. Paresthesia of the infraorbital nerve was present in two patients, and recovered completely in four weeks after surgery. Fracture reduction was considered to be satisfactory in all cases. One patient developed postsurgical infection and was managed with oral antibiotics and analgesics. Favorable healing can be observed through the use of biodegradable plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood, however further studies with more sample size are required.

  11. Heat generation during removal of an abutment screw fragment from dental implants.

    PubMed

    Arias, Sergio R; Rueggeberg, Frederick A; Mettenburg, Donald; Sharawy, Mohamed; Looney, Stephen; Elsayed, Ranya; Elsalanty, Mohammed E

    2018-04-01

    Little information is available on the effect of drilling speed on surrounding bone during the removal of an abutment screw fragment. The purpose of this in vitro study was to compare, in vitro, the peak temperature increase during the removal of fractured abutment screws from implants placed in a porcine mandible, using drilling speeds of 600 or 2000 rpm. Twenty 4.3×13-mm dental implants were placed in 10 dissected porcine mandibles: 2 implants per mandible, 1 on each side. Localized defects were created in 20 surface-treated abutment screws, which were then tightened into each implant until a reproducible fracture occurred in each screw. The fractured screws were removed with a handpiece removal kit and irrigated with room-temperature water at either 600 or 2000 rpm. The temperature rise at the implant surface was measured at 3 levels with 3 type-K thermocouples. Repeated measure ANOVA was performed with the Tukey-Kramer post hoc test for mean pair-wise comparisons (α=.05 for all tests). Mean peak temperatures were significantly higher at 2000 rpm than at 600 rpm in the mid-body (P<.001) and crestal (P=.003) regions but not in the apical (P=.225) implant locations. No significant differences in mean peak temperatures were found among the 3 locations using 600 rpm (P=.179). In the 2000-rpm group, mean peak temperature in the mid-body area was consistently higher than that in the apical (P<.001) area, and more instances of temperature rise above 56°C and 60°C were observed. In 1 implant from this group, the estimated peak temperature exceeded the bone damage threshold value (50°C for 30 seconds). A drilling speed of 2000 rpm during the removal of abutment screw fragments caused overheating of the outer surface of the implant which may damage the surrounding bone; a speed of 600 rpm appears to be safe. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.

    PubMed

    Windolf, Markus; Klos, Kajetan; Wähnert, Dirk; van der Pol, Bas; Radtke, Roman; Schwieger, Karsten; Jakob, Roland P

    2010-05-21

    Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic compression plate) and LCP (locking compression plate) stabilization, in a human cadaveric diaphyseal gap model. In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p bone-plate contact revealed larger fracture gap motion under axial compression compared to the conventional LC-DCP osteosynthesis (p screw heads. Even though accentuated fracture gap motion became obvious, the "Fence" technique is considered an alternative to cost-intensive locking-head devices. The concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.

  13. [Atlanto-axial pedicle screw fixation through posterior approach for treatment of atlanto-axial joint instability].

    PubMed

    Zuo, Chun-Guang; Liu, Xia-Jun; Wang, Xin-Hu; Wang, Jian-shun

    2013-01-01

    To discuss the therapeutic effects of the atlantoaxial pedicle screw system fixation in treatment of atlantoaxial instability. From June 2003 to March 2010, 32 patients with atlantoaxial instability were treated by atlantoaxial pedicle screw system fixation, included 21 males and 11 females wiht an average age of 42.5 years old ranging from 28 to 66 years. Among them, 18 cases were odontoid process fractures, 7 were congenital dissociate odontoid process, 4 were Jefferson fracture combined with odontoid fracture, 3 were rheumatic arthritis causing atlantoaxial instability. All patients suffered from the atlantoaxial subluxation and atlantoaxial instability. The JOA score ranged from 4 to 14 (means 9.1 +/- 0.3) before operation. The patients had some image examination including the X-ray of cervical vertebrae (include of dynamic position film), spiral CT 3D reconstruction and/or MRI. The position of pedicle screw system implantation,the angle of pedicle screw system implantation and screw length were measured. Operating skull traction. Operation undewent general anesthesia, implanted the pedicle screw, reduction and bone fusion under direct vision. The bone was fixated between posterior arch of atlas and lamina of axis by the lateral combination bended to posterior. One hundred and twenty-eight atlantoaxial pedicle screws were implanted in 32 patients. No patient had the injure of spinal cord, nerve root and vertebral artery. All patients were followed-up from 6 to 48 months (averaged 16 months). After operation, the JOA score ranged from 11 to 17 (averaged 15.9 +/- 0.2), improvement rate was 86.1%. The fracture of odontoid process were healing completely. All fusion bone were combinated. The internal fixation wasn't loosening and breaking. The atlantoaxial pedicle screw system fixation was effective method to treat atlantoaxial instability. The method had many advantages, such as provide rigid and short segment fixation, safe and simple, high fusion rate. The

  14. Healing at the interface between recipient sites and autologous block bone grafts affixed by either position or lag screw methods: a histomorphometric study in rabbits.

    PubMed

    Caneva, Marco; Botticelli, Daniele; Carneiro Martins, Evandro Neto; Caneva, Martina; Lang, Niklaus P; Xavier, Samuel P

    2017-12-01

    To compare the sequential healing at the interface gap occurring between autologous bone grafts and recipient sites using two types of fixation techniques. Twenty-four adult male New Zealand white rabbits were used. Two bone grafts were collected from the calvaria and secured to the lateral aspect of the angle of mandible in each animal. Cortical perforations at the recipient sites were performed. However, no modifications were applied to the graft for its adaptation to the recipient site. Two types of fixation techniques by position or lag screws were applied. This was done by preparing osteotomy holes smaller or larger than the screw diameter, respectively. The animals were sacrificed after 3, 7, 20, and 40 days. After 3 days, the distance between the graft and the recipient site was similar between the two different fixations. Due to the anatomical shapes of the recipient sites and grafts, the distance between the two parts was lower in the central region (<0.1 mm) compared to the external regions of the graft (0.5-0.6 mm). The first evidence of small amounts of new (woven) bone was seen after 7 days, forming from the parent bone. The percentage increased after 20 and 40 days. After 40 days, the grafts were well incorporated within the recipient sites in both groups without any statistically significant difference. The present study did not show superiority of one method over another. A fixation to a recipient site with perforations may be sufficient for incorporating an autologous bone graft even if its adaptation is not perfect and irrespectively of the fixation method. Distances of approximately half millimeter were bridged with newly formed bone. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Removal torque of nail interlocking screws is related to screw proximity to the fracture and screw breakage.

    PubMed

    White, Alexander A; Kubacki, Meghan R; Samona, Jason; Telehowski, Paul; Atkinson, Patrick J

    2016-06-01

    Studies have shown that titanium implants can be challenging to explant due to the material's excellent biocompatibility and resulting osseointegration. Clinically, titanium alloy nail interlocking screws may require removal to dynamize a construct or revise the nail due to nonunion, infection, pain, or periprosthetic fracture. This study was designed to determine what variables influence the removal torque for titanium alloy interlocking screws. An intramedullary nail with four interlocking screws was used to stabilize a 1-cm segmental femoral defect in a canine model for 16 weeks. The animals were observed to be active following a several-day recovery after surgery. In six animals, the femora and implanted nail/screws were first tested to failure in torsion to simulate periprosthetic fracture of an implant after which the screws were then removed. In four additional animals, the screws were removed without mechanical testing. Both intraoperative insertional and extraction torques were recorded for all screws. Mechanical testing to failure broke 10/24 screws. On average, the intact screws required 70% of the insertional torque during removal while broken screws only required 16% of the insertional torque (p < 0.001). In addition, intact screws closer to the fracture required 2.8 times more removal torque than the outboard distal screw (p < 0.005). On average, the angle of rotation to peak torque was ∼80°. The peak axial load did not significantly correlate with the torque required to remove the screws. On average, the removal torque was lower than at the time of insertion, and less torque was required to remove broken screws and screws remote to the fracture. However, broken screws will require additional time to retrieve the remaining screw fragment. This study suggests that broken screws and screws in prematurely active patients will require less torque to remove. © IMechE 2016.

  16. Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study.

    PubMed

    Kanneganti, Krishna Chaitanya; Vinnakota, Dileep Nag; Pottem, Srinivas Rao; Pulagam, Mahesh

    2018-01-01

    The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled to form 8 simulations. After discretization, the contact stresses developed for 150 N vertical and 100 N oblique load applications were analyzed, using ABAQUS. By assessing damage initiation and shortest fatigue load on screw threads, the SL for 2.5, 5, and 10 lakh cyclic loads were estimated, using fe-safe program. The obtained values were compared for influence of connection design, abutment angulation, and screw length. In straight abutment models, conical connection showed more damage (14.3%-72.3%) when compared to trilobe (10.1%-65.73%) at 2.5, 5, and 10 lakh cycles for both vertical and oblique loads, whereas in angulated abutments, trilobe (16.1%-76.9%) demonstrated more damage compared to conical (13.5%-70%). Irrespective of the connection type and abutment angulation, short screws showed more percentage of damage compared to long screws. The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws.

  17. A customized fixation plate with novel structure designed by topological optimization for mandibular angle fracture based on finite element analysis.

    PubMed

    Liu, Yun-Feng; Fan, Ying-Ying; Jiang, Xian-Feng; Baur, Dale A

    2017-11-15

    The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA). A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as "V" pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the "V" plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed. The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems. The

  18. Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins.

    PubMed

    Christie, J; Howie, C R; Armour, P C

    1988-03-01

    One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.

  19. Ball Screw Actuator Including a Compliant Ball Screw Stop

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2015-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  20. Ball Screw Actuator Including a Compliant Ball Screw Stop

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2017-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  1. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures

    PubMed Central

    Vegt, Paul; Muir, Jeffrey M; Block, Jon E

    2014-01-01

    The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS) is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS. PMID:25540600

  2. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures.

    PubMed

    Vegt, Paul; Muir, Jeffrey M; Block, Jon E

    2014-01-01

    The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS) is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS.

  3. [Ex Vivo Testing of Mechanical Properties of Canine Metacarpal/Metatarsal Bones after Simulated Implant Removal].

    PubMed

    Srnec, R; Fedorová, P; Pěnčík, J; Vojtová, L; Sedlinská, M; Nečas, A

    2016-01-01

    EXP, were compared and the difference was found to be statistically significant (p ≤ 0.05). CONCLUSIONS The recently developed biodegradable polymer-composite gel is easy and quick to apply to any defect, regardless of its shape, in bone tissue. The ex vivo mechanical tests on canine short bones showed that the composite applied to defects, which simulated holes left after screw removal, provided sufficient mechanical support to the bone architecture. The results of measuring maximum loading forces were statistically significant. However, before the composite could be recommended for use in veterinary or human medical practice, thorough pre-clinical studies will be required. fracture fixation, mechanical testing, bone plate, cortical screw, refracture.

  4. Lateral column lengthening using allograft interposition and cervical plate fixation.

    PubMed

    Philbin, Terrence M; Pokabla, Christopher; Berlet, Gregory C

    2008-10-01

    Lateral column lengthening has been used successfully in the treatment of stage II adult-acquired pes planovalgus deformity. The purpose of this study is to review the union rate when allograft material is used and the osteotomy stabilized with a cervical plate. A retrospective review was performed on 28 feet in 26 patients who underwent correction of stage II pes planovalgus deformity using a lateral column lengthening with allograft tricortical iliac crest stabilized with a cervical plate. Patients were evaluated preoperatively and postoperatively using a modified American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale and the Short Form-12 health survey, as well as radiographically by assessing the talonavicular coverage angle. At a mean follow-up of 9 months, the mean total modified AOFAS score and pain subscore were significantly higher (45.6 and 25.0, respectively) versus preoperatively (27.3 and 11.2, respectively). Graft incorporation occurred in all but one case, and the average length of time to union was 10.06 weeks. Complications included 4 hardware removals, 1 nonunion, 1 graft penetration of the calcaneocuboid joint, and 2 cases of calcaneocuboid joint arthritis. Lateral column lengthening using allograft tricortical iliac crest bone graft with cervical plate fixation is a viable option for the correction of acquired pes planovalgus deformity. Allograft bone avoids donor site morbidity of autogenous iliac crest grafts and was not shown to increase rates of nonunion. Cervical plate fixation avoids the necessity of penetrating the graft with a screw and is associated with high patient satisfaction and radiographic union.

  5. Cement Augmentation in Sacroiliac Screw Fixation Offers Modest Biomechanical Advantages in a Cadaver Model.

    PubMed

    Osterhoff, Georg; Dodd, Andrew E; Unno, Florence; Wong, Angus; Amiri, Shahram; Lefaivre, Kelly A; Guy, Pierre

    2016-11-01

    Sacroiliac screw fixation in elderly patients with pelvic fractures is prone to failure owing to impaired bone quality. Cement augmentation has been proposed as a possible solution, because in other anatomic areas this has been shown to reduce screw loosening. However, to our knowledge, this has not been evaluated for sacroiliac screws. We investigated the potential biomechanical benefit of cement augmentation of sacroiliac screw fixation in a cadaver model of osteoporotic bone, specifically with respect to screw loosening, construct survival, and fracture-site motion. Standardized complete sacral ala fractures with intact posterior ligaments in combination with ipsilateral upper and lower pubic rami fractures were created in osteoporotic cadaver pelves and stabilized by three fixation techniques: sacroiliac (n = 5) with sacroiliac screws in S1 and S2, cemented (n = 5) with addition of cement augmentation, and transsacral (n = 5) with a single transsacral screw in S1. A cyclic loading protocol was applied with torque (1.5 Nm) and increasing axial force (250-750 N). Screw loosening, construct survival, and sacral fracture-site motion were measured by optoelectric motion tracking. A sample-size calculation revealed five samples per group to be required to achieve a power of 0.80 to detect 50% reduction in screw loosening. Screw motion in relation to the sacrum during loading with 250 N/1.5 Nm was not different among the three groups (sacroiliac: 1.2 mm, range, 0.6-1.9; cemented: 0.7 mm, range, 0.5-1.3; transsacral: 1.1 mm, range, 0.6-2.3) (p = 0.940). Screw subsidence was less in the cemented group (3.0 mm, range, 1.2-3.7) compared with the sacroiliac (5.7 mm, range, 4.7-10.4) or transsacral group (5.6 mm, range, 3.8-10.5) (p = 0.031). There was no difference with the numbers available in the median number of cycles needed until failure; this was 2921 cycles (range, 2586-5450) in the cemented group, 2570 cycles (range, 2500-5107) for the sacroiliac specimens, and

  6. The potential of mangosteen (Garcinia mangostana) peel extract, combined with demineralized freeze-dried bovine bone xenograft, to reduce ridge resorption and alveolar bone regeneration in preserving the tooth extraction socket.

    PubMed

    Kresnoadi, Utari; Ariani, Maretaningtias Dwi; Djulaeha, Eha; Hendrijantini, Nike

    2017-01-01

    Following the extraction of a tooth, bone resorption can cause significant problems for a subsequent denture implant and restorative dentistry. Thus, the tooth extraction socket needs to be maintained to reduce the chance of any alveolar ridge bone resorption. The objective of this study is to determine whether the administration of mangosteen peel extracts (MPEs), combined with demineralized freeze-dried bovine bone xenograft (DFBBX) materials for tooth extraction socket preservation, could potentially reduce inflammation by decreased the expression of nuclear factor κβ (NfKb) and receptor activator of nuclear factor-κβ ligand (RANKL), to inhibit alveolar bone resorption, and increased of bone morphogenetic protein-2 (BMP2) expressions to accelerate alveolar bone regeneration. This study consists of several stages. First, a dosage of MPE combined with graft materials was applied to a preserved tooth extraction socket of a Cavia cobaya . Second, the C. cobaya was examined using immune histochemical expression of NfKb, RANKL, BMP2, as well as histology of osteoblasts and osteoclasts. The research was statistically analyzed, using an analysis of variance test and Tukey honest significant difference test. The results of this research were that it was determined that MPEs combined with graft materials on a preserved tooth extraction socket can reduce NfKb, RANK, and osteoclasts also increase of BMP2 and osteoblast. The induction of MPEs and DFBBX is effective in reducing inflammation, lowering osteoclasts, decreasing alveolar bone resorption, and also increasing BMP2 expression and alveolar bone regeneration.

  7. Fully customized placement of orthodontic miniplates: a novel clinical technique

    PubMed Central

    2014-01-01

    Introduction The initial stability and survival rate of orthodontic mini-implants are highly dependent on the amount of cortical bone at their insertion site. In areas with limited bone availability, mini-plates are preferred to provide effective skeletal anchorage. The purpose of this paper was to present a new clinical technique for the insertion of mini-plates. Methods In order to apply this new technique, a cone-beam image of the insertion area is required. A software (Galaxy Sirona, Bensheim, Germany) is used to construct a three-dimensional image of the scanned area and to virtually determine the exact location of the mini-plate as well as the position of the fixation screws. A stereolithographic model (STL) is then created by means of a three-dimensional scanner. Prior to its surgical insertion, the bone plate is adapted to the stereo-lithographic model. Finally, a custom transfer jig is fabricated in order to assist with accurate placement of the mini-plate intra-operatively. Results The presented technique minimizes intra-operative decision making, because the final position of the bone plate is determined pre-surgically. This significantly reduces the duration of the surgical procedure and improves its outcome. Conclusions A novel method for surgical placement of orthodontic mini-plates is presented. The technique facilitates accurate adaptation of mini-plates and insertion of retaining surgical screws; thereby enabling clinicians to more confidently increase the use of bone plates, especially in anatomical areas where the success of non-osseointegrated mini-screws is less favorable. PMID:24886597

  8. Loss of mechanical properties in vivo and bone-implant interface strength of AZ31B magnesium alloy screws with Si-containing coating.

    PubMed

    Tan, Lili; Wang, Qiang; Lin, Xiao; Wan, Peng; Zhang, Guangdao; Zhang, Qiang; Yang, Ke

    2014-05-01

    In this study the loss of mechanical properties and the interface strength of coated AZ31B magnesium alloy (a magnesium-aluminum alloy) screws with surrounding host tissues were investigated and compared with non-coated AZ31B, degradable polymer and biostable titanium alloy screws in a rabbit animal model after 1, 4, 12 and 21weeks of implantation. The interface strength was evaluated in terms of the extraction torque required to back out the screws. The loss of mechanical properties over time was indicated by one-point bending load loss of the screws after these were extracted at different times. AZ31B samples with a silicon-containing coating had a decreased degradation rate and improved biological properties. The extraction torque of Ti6Al4V, poly-l-lactide (PLLA) and coated AZ31B increased significantly from 1week to 4weeks post-implantation, indicating a rapid osteosynthesis process over 3weeks. The extraction torque of coated AZ31B increased with implantation time, and was higher than that of PLLA after 4weeks of implantation, equalling that of Ti6Al4V at 12weeks and was higher at 21weeks. The bending loads of non-coated AZ31B and PLLA screws degraded sharply after implantation, and that of coated AZ31B degraded more slowly. The biodegradation mechanism, the coating to control the degradation rate and the bioactivity of magnesium alloys influencing the mechanical properties loss over time and bone-implant interface strength are discussed in this study and it is concluded that a suitable degradation rate will result in an improvement in the mechanical performance of magnesium alloys, making them more suitable for clinical application. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  9. Accuracy of screw fixation using the O-arm® and StealthStation® navigation system for unstable pelvic ring fractures.

    PubMed

    Takeba, Jun; Umakoshi, Kensuke; Kikuchi, Satoshi; Matsumoto, Hironori; Annen, Suguru; Moriyama, Naoki; Nakabayashi, Yuki; Sato, Norio; Aibiki, Mayuki

    2018-04-01

    Screw fixation for unstable pelvic ring fractures is generally performed using the C-arm. However, some studies reported erroneous piercing with screws, nerve injuries, and vessel injuries. Recent studies have reported the efficacy of screw fixations using navigation systems. The purpose of this retrospective study was to investigate the accuracy of screw fixation using the O-arm ® imaging system and StealthStation ® navigation system for unstable pelvic ring fractures. The participants were 10 patients with unstable pelvic ring fractures, who underwent screw fixations using the O-arm StealthStation navigation system (nine cases with iliosacral screw and one case with lateral compression screw). We investigated operation duration, bleeding during operation, the presence of complications during operation, and the presence of cortical bone perforation by the screws based on postoperative CT scan images. We also measured the difference in screw tip positions between intraoperative navigation screen shot images and postoperative CT scan images. The average operation duration was 71 min, average bleeding was 12 ml, and there were no nerve or vessel injuries during the operation. There was no cortical bone perforation by the screws. The average difference between intraoperative navigation images and postoperative CT images was 2.5 ± 0.9 mm, for all 18 screws used in this study. Our results suggest that the O-arm StealthStation navigation system provides accurate screw fixation for unstable pelvic ring fractures.

  10. Horizontal Guided Bone Regeneration in the Esthetic Area with rhPDGF-BB and Anorganic Bovine Bone Graft: A Case Report.

    PubMed

    Chiantella, Giovanni Carlo

    2016-01-01

    The present article describes the treatment given to a patient who underwent horizontal ridge augmentation surgery in the maxillary anterior area due to the premature loss of the maxillary central incisors. The complete dehiscence of the buccal plate was detected after elevation of mucoperiosteal flaps. The lesion was overfilled with deproteinized bovine xenograft particles combined with recombinant human platelet-derived growth factor BB (rhPDGF-BB) and covered with a porcine collagen barrier hydrated with the same growth factor. The soft tissues healed with no adverse complications. After 12 months, reentry surgery was carried out to place endosseous implants. Complete bone regeneration with the presence of bone-like tissue was observed. Cross-sectional computed tomography scan images confirmed integration of the bone graft and reconstruction of the lost hard tissue volume. The implants were inserted in an optimal three-dimensional position, thus facilitating esthetic restoration. Two years after insertion of final crowns, cone beam computed tomography scans displayed the stability of regenerated hard tissues around the implants. Controlled clinical studies are necessary to determine the benefit of hydrating bovine bone particles and collagen barriers with rhPDGF-BB for predictable bone regeneration of horizontal lesions.

  11. Scapula fracture incidence in reverse total shoulder arthroplasty using screws above or below metaglene central cage: clinical and biomechanical outcomes.

    PubMed

    Kennon, Justin C; Lu, Caroline; McGee-Lawrence, Meghan E; Crosby, Lynn A

    2017-06-01

    Reverse total shoulder arthroplasty (RTSA) is a viable treatment option for rotator cuff tear arthropathy but carries a complication risk of scapular fracture. We hypothesized that using screws above the central glenoid axis for metaglene fixation creates a stress riser contributing to increased scapula fracture incidence. Clinical type III scapular fracture incidence was determined with screw placement correlation: superior screw vs. screws placed exclusively below the glenoid midpoint. Cadaveric RTSA biomechanical modeling was employed to analyze scapular fractures. We reviewed 318 single-surgeon single-implant RTSAs with screw correlation to identify type III scapular fractures. Seventeen cadaveric scapula specimens were matched for bone mineral density, metaglenes implanted, and fixation with 2 screw configurations: inferior screws alone (group 1 INF ) vs. inferior screws with one additional superior screw (group 2 SUP ). Biomechanical load to failure was analyzed. Of 206 patients, 9 (4.4%) from the superior screw group experienced scapula fractures (type III); 0 fractures (0/112; 0%) were identified in the inferior screw group. Biomechanically, superior screw constructs (group 2 SUP ) demonstrated significantly (P < .05) lower load to failure (1077 N vs. 1970 N) compared with constructs with no superior screws (group 1 INF ). There was no significant age or bone mineral density discrepancy. Clinical scapular fracture incidence significantly decreased (P < .05) for patients with no screws placed above the central cage compared with patients with superior metaglene screws. Biomechanical modeling demonstrates significant construct compromise when screws are used above the central cage, fracturing at nearly half the ultimate load of the inferior screw constructs. We recommend use of inferior screws, all positioned below the central glenoid axis, unless necessary to stabilize the metaglene construct. Copyright © 2016 Journal of Shoulder and Elbow Surgery

  12. Bone remodelling of a proximal femur with the thrust plate prosthesis: an in vitro case.

    PubMed

    Taylor, W R; Ploeg, H; Hertig, D; Warner, M D; Clift, S E

    2004-06-01

    The key to the development of a successful implant is an understanding of the effect of bone remodelling on its long-term fixation. In this study, clinically observed patterns of bone remodelling have been compared with computer-based predictions for one particular design of prosthesis, the Thrust Plate Prosthesis (Centerpulse Orthopedics, Winterthur, Switzerland). Three-dimensional finite-element models were created using geometrical and bone density data obtained from CT scanning. Results from the bone remodelling simulation indicated that varying the relative rate of bone deposition/resorption and the interfacial conditions between the bone and the implant could produce the trend towards the two clinically observed patterns of remodelling.

  13. Effects of mangosteen peel extract combined with demineralized freeze-dried bovine bone xenograft on osteocalcin, collagen 1, and osteoblast as alveolar bone regeneration in socket preservation.

    PubMed

    Kresnoadi, Utari; Raharjo, Tika; Rostiny, Rostiny

    2018-01-01

    Tooth extraction will provoke changes in alveolar bone morphology and dimensions. Postextraction bone resorption can lead to significant problems for restorative dentistry. Therefore, the extracted tooth socket needs to be preserved to reduce alveolar ridge bone resorption. This research aimed to analyze the expression and levels of osteocalcin, collagen 1, and osteoblasts in extracted tooth sockets filled with a combination of mangosteen peel extract and demineralized freeze-dried bovine bone xenograft (DFDBBX). Fifty-six Cavia cobaya , whose lower left incisors had been extracted, were divided into eight groups according to the substance used to fill their sockets on days 7 and 30, Poly ethylene glycol, DFDBBX, mangosteen peel extract, or a combination of mangosteen peel extract and DFDBBX. This research was conducted in several stages; the application of mangosteen peel extract combined with graft material was performed as the form of tooth extraction socket preservation. The C. cobaya rats were subsequently examined by immunohistochemical methods to measure osteocalcin and collagen 1 expressions, whereas histological examination was conducted to calculate the number of osteoblasts in accordance with the duration of the research. On days 7 and 30, the group treated with a combination of DFDBBX and mangosteen peel extract which had the highest expression and levels of osteocalcin, collagen 1, and osteoblasts. The administration of mangosteen peel extract combined with DFDBBX as a means of tooth extraction socket preservation can increase osteocalcin and collagen 1 expression. Consequently, osteoblasts as a means of alveolar bone regeneration will increase in number.

  14. [Comparison of screw' inserting angle through the 11th and 12th rib anterior approaches for L1 burst fracture].

    PubMed

    Ma, Li-Tai; Liu, Hao; Li, Tao; Song, Yue-Ming; Pei, Fu-Xing; Liu, Li-Min; Gong, Quan; Zeng, Jian-Cheng; Feng, Gan-Jun; Zhou, Zhong-Jie

    2012-12-01

    To compare screw's inserting angle through the 11th and 12th rib in treating L1 burst fracture, explore effects on inserting screw and postoperative angle. From October 2007 to October 2010, 108 patients with L1 brust fracture treated through anterior approach were analyzed,including 68 males and 40 females, aged from 21 to 64 years (mean 38.22 years). All patients were divided into the 11th (A, 51 cases) and 12th (B, 57 cases) approach. The data of operation time,blood loss, duration of incision pain, JOA score, Oswestry score, VAS score, quality of life (SF-36), recovery of nervous function, coronal Cobb angle, included angle between screw and plate were observed. All patients were followed up for 9 to 37 months, mean 23 months. The operation time, blood loss, duration of incision pain, in group A were lower than group B (P<0.05), JOA score, Oswestry score, VAS score, SF-36, recovery of nervous function had no significant differences (P>0.05). There were no differences in Cobb angle before operation, but had significance after operation (P=0.000). There were statistically significance between two group in angle between screw and plate (P=0.000, P=0.003). The 11th rib approach for the treatment of L1 burst fracture has less effects on screw, less trauma and less angle between screw and plate.

  15. Immediate prosthesis over implants retained using abutments with flexible screws: A preliminary study.

    PubMed

    Peñarrocha-Oltra, David; Serra-Pastor, Blanca; Balaguer-Martí, José-Carlos; Peñarrocha-Diago, Miguel; Agustín-Panadero, Rubén

    2017-12-01

    Immediate loading protocols for the rehabilitation of edentulous or partially edentulous patients have become very popular, due to the conveniences they afford in comparison with conventional loading techniques. A preliminary study was carried out with 8 patients subjected to dental implant treatment with an immediate loading protocol involving a novel system of abutments with flexible screws. Implant survival was analyzed, together with marginal bone loss and patient and dentist satisfaction. A total of 35 implants were subjected to immediate loading using the abutments with flexible screws. The mean patient and dentist satisfaction score was 9.1 and 8.5, respectively. After 12 months the dental implant survival rate was 95.8%, with a mean marginal bone loss of 0.51 ± 0.12 mm. The novel system of abutments with flexible screws offers a good alternative to conventional immediate loading, since it allows rapid and simple manufacture of a reliable passive fit, fixed interim prosthesis after surgery. Key words: Dental implants, Flexafit®, Immediate loading, Immediate prosthesis.

  16. Osteogenesis and cytotoxicity of a new Carbon Fiber/Flax/Epoxy composite material for bone fracture plate applications.

    PubMed

    Bagheri, Zahra S; Giles, Erica; El Sawi, Ihab; Amleh, Asma; Schemitsch, Emil H; Zdero, Radovan; Bougherara, Habiba

    2015-01-01

    This study is part of an ongoing program to develop a new CF/Flax/Epoxy bone fracture plate to be used in orthopedic trauma applications. The purpose was to determine this new plate's in-vitro effects on the level of bone formation genes, as well as cell viability in comparison with a medical grade metal (i.e. stainless steel) commonly employed for fabrication of bone plates (positive control). Cytotoxicity and osteogenesis induced by wear debris of the material were assessed using Methyl Tetrazolium (MTT) assay and reverse transcription polymerase chain reaction (RT-PCR) for 3 osteogenesis specific gene markers, including bone morphogenetic proteins (BMP2), runt-related transcription factor 2 (Runx2) and Osterix. Moreover, the Flax/Epoxy and CF/Epoxy composites were examined separately for their wettability properties by water absorption and contact angle (CA) tests using the sessile drop technique. The MTT results for indirect and direct assays indicated that the CF/Flax/Epoxy composite material showed comparable cell viability with no cytotoxicity at all incubation times to that of the metal group (p≥0.05). Osteogenesis test results showed that the expression level of Runx2 marker induced by CF/Flax/Epoxy were significantly higher than those induced by metal after 48 h (p=0.57). Also, the Flax/Epoxy composite revealed a hydrophilic character (CA=68.07°±2.05°) and absorbed more water up to 17.2% compared to CF/Epoxy, which reached 1.25% due to its hydrophobic character (CA=93.22°±1.95°) (p<0.001). Therefore, the new CF/Flax/Epoxy may be a potential candidate for medical applications as a bone fracture plate, as it showed similar cell viability with no negative effect on gene expression levels responsible for bone formation compared to medical grade stainless steel. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Effects of Lateral Mass Screw Rod Fixation to the Stability of Cervical Spine after Laminectomy

    NASA Astrophysics Data System (ADS)

    Rosli, Ruwaida; Kashani, Jamal; Kadir, Mohammed Rafiq Abdul

    There are many cases of injury in the cervical spine due to degenerative disorder, trauma or instability. This condition may produce pressure on the spinal cord or on the nerve coming from the spine. The aim of this study was, to analyze the stabilization of the cervical spine after undergoing laminectomy via computational simulation. For that purpose, a three-dimensional finite element (FE) model for the multilevel cervical spine segment (C1-C7) was developed using computed tomography (CT) data. There are various decompression techniques that can be applied to overcome the injury. Usually, decompression procedures will create an unstable spine. Therefore, in these situations, the spine is often surgically restabilized by using fusion and instrumentation. In this study, a lateral mass screw-rod fixation was created to stabilize the cervical spine after laminectomy. Material properties of the titanium alloy were assigned on the implants. The requirements moments and boundary conditions were applied on simulated implanted bone. Result showed that the bone without implant has a higher flexion and extension angle in comparison to the bone with implant under applied 1Nm moment. The bone without implant has maximum stress distribution at the vertebrae and ligaments. However, the bone with implant has maximum stress distribution at the screws and rods. Overall, the lateral mass screw-rod fixation provides stability to the cervical spine after undergoing laminectomy.

  18. Biomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation.

    PubMed

    Park, Jin-Woo; Kim, Kyoung-Tae; Sung, Joo-Kyung; Park, Seong-Hyun; Seong, Ki-Woong; Cho, Dae-Chul

    2017-09-01

    The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm long 4.0-mm cannulated lag screws (n=7 and n=10, respectively) after insertion into rigid polyurethane foam test blocks (Sawbones, Vashon, WA, USA). A washer load cell was placed between the two segments of test blocks to measure the compression force. Because the total length of each foam block was 42 mm, the 40-mm screws were embedded in the cancellous foam, while the 45-mm screws penetrated the denser cortical foam at the bottom. This enabled us to compare inter-fragmentary compression pressures as they are affected by the penetration of the apical dens tip by the screws. The mean compression pressures of the 40- and 45-mm long cannulated lag screws were 50.48±1.20 N and 53.88±1.02 N, respectively, which was not statistically significant (p=0.0551). The mean compression pressures of the 40-mm long Herbert screw was 52.82±2.17 N, and was not statistically significant compared with the 40-mm long cannulated lag screw (p=0.3679). However, 45-mm Herbert screw had significantly higher mean compression pressure (60.68±2.03 N) than both the 45-mm cannulated lag screw and the 40-mm Herbert screw (p=0.0049 and p=0.0246, respectively). Our results showed that inter-fragmentary compression pressures of the Herbert screw were significantly increased when the screw tip penetrated the opposite dens cortical foam. This can support the generally recommended surgical technique that, in order to facilitate maximal reduction of the fracture gap using anterior odontoid screws, it is essential to penetrate the apical dens tip with the screw.

  19. Cervical anterior transpedicular screw fixation (ATPS)—Part II. Accuracy of manual insertion and pull-out strength of ATPS

    PubMed Central

    Acosta, Frank; Tauber, Mark; Fox, Michael; Martin, Hudelmaier; Forstner, Rosmarie; Augat, Peter; Penzkofer, Rainer; Pirich, Christian; Kässmann, H.; Resch, Herbert; Hitzl, Wolfgang

    2008-01-01

    Reconstruction after multilevel decompression of the cervical spine, especially in the weakened osteoporotic, neoplastic or infectious spine often requires circumferential stabilization and fusion. To avoid the additional posterior surgery in these cases while increasing rigidity of anterior-only screw-plate constructs, the authors introduce the concept of anterior transpedicular screw (ATPS) fixation. We demonstrated its morphological feasibility as well as its indications in a previous study in Part I of our project. Consequently, the objectives of the current study were to assess the ex vivo accuracy of placing ATPS into the cervical vertebra as well as the biomechanical performance of ATPS in comparison to traditional vertebral body screws (VBS) in terms of pull-out strength (POS). Twenty-three ATPS were inserted alternately to two screws into the pedicles and vertebral bodies, respectively, of six cadaveric specimens from C3–T1. For insertion of ATPS, a manual fluoroscopically assisted technique was used. Pre- and post insertional CT-scans were used to assess accuracy of ATPS insertion in the axial and sagittal planes. A newly designed grading system and accuracy score were used to delineate accuracy of ATPS insertion. Following insertion of screws, 23 ATPS and 22 VBS were subjected to pull-out testing (POT). The bone mineral density (BMD) of each specimen was assessed prior to POT. Statistical analysis showed that the incidence of correctly placed screws and non-critical pedicles breaches in axial plane was 78.3%, and 95.7% in sagittal plane. Hence, according to our definition of “critical” pedicle breach that exposes neurovascular structures at risk, 21.7% (n = 5) of all ATPS inserted showed a critical pedicle breach in axial plane. Notably, no critical pedicle perforation occurred at the C6 to T1 levels. Pull-out testing of ATPS and VBS revealed that pull-out resistance of ATPS was 2.5-fold that of VBS. Mean POS of 23 ATPS with a mean BMD of 0.566

  20. Possible Vascular Injury Due to Screw Eccentricity in Minimally Invasive Total Hip Arthroplasty.

    PubMed

    Singh, Nishant Kumar; Rai, Sanjay Kumar; Rastogi, Amit

    2017-01-01

    Vascular injury during minimally invasive total hip arthroplasty (THA) is uncommon, yet a well-recognized and serious issue. It emerges because of non-visibility of vascular structures proximal to the pelvic bone during reaming, drilling holes, and fixing of screws. Numerous studies have found that screw fixation during cementless THA is beneficial for the initial stability of cup; yet, no anatomical guidelines support angular eccentric screw fixation. In this study, we obtained the pelvic arterial-phase computed tomographic data of thirty eight humans and reconstructed the three-dimensional models of osseous and vessel structures. We performed the surgical simulation to fix these structures with cementless cups and screws with angular eccentricities. The effect of screw eccentricities (angular eccentricities of ±17° and ±34°) on the vascular injury was determined. Measurement between screw and adjoining vessels was performed and analyzed statistically to ascertain a comparative risk study for blood vessels that are not visible during surgery. Authors similarly discussed the significant absence of appreciation of quadrant systems proposed by Wasielewski et al . on eccentric screws. Adjustment of quadrant systems provided by Wasielewski et al . is required for acetabular implants with eccentric holes for fixation of acetabular screws.

  1. Use of fibular bone graft and cancellous screw fixation in the management of neglected femur neck fractures in young patients.

    PubMed

    Khani, Ghulam Mustafa Kaim; Hafeez, Kamran; Bux, Muhammad; Rasheed, Nusrat; Ahmed, Naveed; Anjum, M Perwez

    2017-01-01

    To present the clinical outcome of patients with neglected femur neck fracture treated with fibular bone graft. During May 2010-February 2013, 15 patients younger than 35 years of age with neglected fracture neck of femur were managed with non-vascularized fibular graft and cannulated screws. Fractures were classified according to Sandhu Classification. Hip function was assessed using Harris hip score. Fifteen patients with mean age of 28.67 years were managed. Mean period of delay from injury to presentation was 3.07 months. Mean follow-up was 18.5 months. Union was achieved in 13 cases. 2 patients developed nonunion with progression of avascular necrosis (AVN). Patients with healed fracture did not show radiological signs of AVN till the past follow-up. Functional status was evaluated at 6 months according to Harris hip score and was poor in 2 patients, fair in 2 patients, good in 6 patients, and excellent in 5 patients. Fibular graft along with two cancellous screws proved to be an effective technique in our cases with neglected femur neck fractures.

  2. Biomechanical analysis of clavicle hook plate implantation with different hook angles in the acromioclavicular joint.

    PubMed

    Hung, Li-Kun; Su, Kuo-Chih; Lu, Wen-Hsien; Lee, Cheng-Hung

    2017-08-01

    A clavicle hook plate is a simple and effective method for treating acromioclavicular dislocation and distal clavicle fractures. However, subacromial osteolysis and peri-implant fractures are complicated for surgeons to manage. This study uses finite element analysis (FEA) to investigate the post-implantation biomechanics of clavicle hook plates with different hook angles. This FEA study constructed a model with a clavicle, acromion, clavicle hook plate, and screws to simulate the implantation of clavicle hook plates at different hook angles (90°, 95°, 100°, 105°, and 110°) for treating acromioclavicular joint dislocations. This study investigated the biomechanics of the acromion, clavicle, hook plate, and screws. A smaller hook angle increases the stress on the middle third of the clavicle. A larger hook angle increases the force exerted by the clavicle hook plate on the acromion. The screw at the most medial position on the plate generated the highest stress. The highest stress on the implanted clavicle hook plate was on the turning corner of the hook. A clavicle hook plate with different hook angles may induce different biomechanical behaviors in the clavicle and acromion. Orthopedic surgeons must select a suitable clavicle hook plate based on the anatomical structure of each patient.

  3. Management strategy for unicameral bone cyst.

    PubMed

    Chuo, Chin-Yi; Fu, Yin-Chih; Chien, Song-Hsiung; Lin, Gau-Tyan; Wang, Gwo-Jaw

    2003-06-01

    The management of a unicameral bone cyst varies from percutaneous needle biopsy, aspiration, and local injection of steroid, autogenous bone marrow, or demineralized bone matrix to the more invasive surgical procedures of conventional curettage and grafting (with autogenous or allogenous bone) or subtotal resection with bone grafting. The best treatment for a unicameral bone cyst is yet to be identified. Better understanding of the pathology will change the concept of management. The aim of treatment is to prevent pathologic fracture, to promote cyst healing, and to avoid cyst recurrence and re-fracture. We retrospectively reviewed 17 cases of unicameral bone cysts (12 in the humerus, 3 in the femur, 2 in the fibula) managed by conservative observation, curettage and bone grafting with open reduction and internal fixation, or continuous decompression and drainage with a cannulated screw. We suggest percutaneous cannulated screw insertion to promote cyst healing and prevent pathologic fracture. We devised a protocol for the management of unicameral bone cysts.

  4. Bioresorbable screws reinforced with phosphate glass fibre: manufacturing and mechanical property characterisation.

    PubMed

    Felfel, R M; Ahmed, I; Parsons, A J; Rudd, C D

    2013-01-01

    Use of bioresorbable screws could eliminate disadvantages associated with metals such as removal operations, corrosion, MRI interference and stress shielding. Mechanical properties of bioresorbable polymers alone are insufficient for load bearing applications application as screws. Thus, reinforcement is necessary to try and match or surpass the mechanical properties of cortical bone. Phosphate based glass fibres were used to reinforce polylactic acid (PLA) in order to produce unidirectionally aligned (UD) and unidirectionally plus randomly distributed (UD/RM) composite screws (P40 UD and P40 UD/RM). The maximum flexural and push-out properties for the composite screws (P40 UD and P40 UD/RM) increased by almost 100% in comparison with the PLA screws. While the pull-out strength and stiffness of the headless composite screws were ∼80% (strength) and ∼130% (stiffness) higher than for PLA, those with heads exhibited properties lower than those for PLA alone as a result of failure at the heads. An increase in the maximum shear load and stiffness for the composite screws (∼30% and ∼40%) in comparison to the PLA screws was also seen. Maximum torque for the PLA screws was ∼1000 mN m, while that for the composite screws were slightly lower. The SEM micrographs for P40 UD and P40 UD/RM screws revealed small gaps around the fibres, which were suggested to be due to buckling of the UD fibres during the manufacturing process. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. [Our experience about the use of resorbable plates in the treatment of craniostenosis].

    PubMed

    Grassiot, B; Delabar, V; Szathmari, A; Beuriat, P A; Paulus, C; Mottolese, C

    2015-09-01

    The use of resorbable plates increases for craniosynostosis surgery. This material, based on polymere (PLA, PGA) can replace steel wire and non resorbable plates. A few studies present surgical results about the use of this material with a long follow-up. We present our ten years experience of using resorbable material for craniosynostosis treatment in children. Between 2002 and 2012, we operated 283 craniosynostosis (98 scaphocephalies, 55 trigonocephalies, 79 plagiocephalies et 51 craniofaciostenoses). Among these surgeries, 211 were realized with resorbable material (plates and screws). Different criteria were observed: the esthetic result, the infection rate, the re-intervention, the bone defects and the inflammatory granuloma. Among the 211 craniosynostosis, we found 62 plagiocephalies, 66 scaphocephalies, 50 trigonocephalies, 33 craniofaciostenoses. All the reconstructions were realized with the same resorbable material (Macropore by Medtronic). The rate of complications was low: one scar infection without participation of material for two patients (0.9%), a pseudo-meningocele for two patients (0.9%), epilepsy for four children (1.8%) and bone defect for 15 (7%). We observed no granuloma for these patients. Our experience of ten years using resorbable material is very satisfactory. This material permits to realize solid and esthetic reconstructions with a low rate of infection without dangerous reaction for children in young age. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.

    PubMed

    Kil, Jin-Sang; Park, Jong-Tae

    2018-05-01

    Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.

  7. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    PubMed

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  8. [Experimental study on carbon fiber reinforced plastic plate--analysis of stabilizing force required for plate].

    PubMed

    Iizuka, H

    1990-11-01

    Plates currently in use for the management of bone fracture made of metal present with various problems. We manufactured carbon fiber reinforced plastic (CFRP) plates from Pyrofil T/530 puriplegs overlaid at cross angles of +/- 10 degrees, +/- 20 degrees, and +/- 30 degrees for trial and carried out an experimental study on rabbit tibiofibular bones using 316L stainless steel plates of comparable shape and size as controls. The results indicate the influence of CFRP plate upon cortical bone was milder than that of stainless steel plate, with an adequate stabilizing force for the repair of fractured rabbit tibiofibular bones. CFRP has the advantages over metals of being virtually free from corrosion and fatigue, reasonably radiolucent and able to meet a wide range of mechanical requirements. This would make CFRP plate quite promising as a new devices of treating fracture of bones.

  9. Treatment for proximal humeral fractures with percutaneous plating: our first results.

    PubMed

    Imarisio, D; Trecci, A; Sabatini, L; Scagnelli, R

    2013-06-01

    Proximal humeral fractures are common lesions; there is no generally accepted strategy about the treatment for displaced and unstable two- to four-part fractures. We have nowadays many different surgical solutions, ranging from percutaneous pinning to shoulder arthroplasty. Percutaneous plating can be a good solution to treat some of these fractures using a minimally invasive technique and performing stable fixation that can allow early mobilization. Purpose of this paper is to evaluate the results of our first cases of percutaneous plating in proximal humeral fractures in order to assess the theoretical advantages and the incidence of possible complications. From June 2009 to February 2012, we treated 29 proximal humeral fractures with a percutaneous plating (NCB-PH plate) through an anterolateral deltoid split. For each patient, we evaluated the clinical outcome according to Constant score and the radiographic results, paying attention to fracture healing, loss of reduction, hardware complications, and head necrosis. The clinical evaluation gave a mean Constant score value of 79 points. Comparing each value to the unaffected shoulder, we could find these results: 7 excellent, 10 good, 8 fair, and 4 poor. No axillary nerve lesions were clinically detected. The radiographic evaluation showed a complete bone healing in all cases within the first 3 months. No head necrosis was detected, as well as screws loosening. In two cases, the X-ray at 2 months revealed a little loss of reduction in varus. Two patients had an anterior pain; in one of these two cases, the plate was removed. In our series, we had no cases of head necrosis, screws cutout, fracture collapse, hardware mobilization, and we think this could be the real advantage of the percutaneous technique compared to the open one, thanks to the reduced biological damage. We had some poor results, related more to patient's age than to other factors. The safety of the technique for the axillary nerve is

  10. Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review.

    PubMed

    Jabran, Ali; Peach, Chris; Ren, Lei

    2018-04-27

    femoral head) was found to improve bone-plate constructs' mechanical performance. Controversy still lies over the use of rigid and semi-rigid implants and the insertion of inferomedial screws for calcar region support. This review will guide the design of in vitro and in silico biomechanical tests and also supplement the study of clinical literature.

  11. Torsional stiffness after subtalar arthrodesis using second generation headless compression screws: Biomechanical comparison of 2-screw and 3-screw fixation.

    PubMed

    Riedl, Markus; Glisson, Richard R; Matsumoto, Takumi; Hofstaetter, Stefan G; Easley, Mark E

    2017-06-01

    Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion. Copyright © 2017. Published by Elsevier Ltd.

  12. A retrospective review of bone tunnel enlargement after anterior cruciate ligament reconstruction with hamstring tendons fixed with a metal round cannulated interference screw in the femur.

    PubMed

    Kobayashi, Masahiko; Nakagawa, Yasuaki; Suzuki, Takashi; Okudaira, Shuzo; Nakamura, Takashi

    2006-10-01

    To assess bone tunnel enlargement after anterior cruciate ligament (ACL) reconstruction with the use of hamstring tendons fixed with a round cannulated interference (RCI) screw in the femur. A consecutive series of 30 ACL reconstructions performed with hamstring tendons fixed with an RCI screw in the femur and with staples via Leeds-Keio ligament in the tibia was retrospectively reviewed. The clinical outcome was evaluated through the Lysholm score. Anterior instability was tested by Telos-SE (Telos Japan, Tokyo, Japan) measurement. The location and angle of each femoral and tibial tunnel were measured with the use of plain radiographs, and bone tunnel enlargement greater than 2 mm detected any time 3, 6, 12, and 24 months postoperatively was defined as positive. Each factor (location and angle of the tunnels, sex, affected side, age, Lysholm score, and Telos-SE measurement) was compared between enlarged and nonenlarged groups. Positive enlargement of the bone tunnel (>2.0 mm) was observed in 36.7% (11 of 30) on the femoral side and 33.3% (10 of 30) on the tibial side, and in 6 knees of both sides. Half of patients (15 of 30) had an enlarged tunnel on the femoral or the tibial side until 1 year postoperatively. In most cases, enlargement reached maximum at 6 months postoperatively. Female patients tended to have an enlarged tunnel, especially on the femoral side (P < .05). Tunnel enlargement was not correlated with location and angle of the tunnels. Moreover, no difference was found in Lysholm score and Telos-SE measurement between enlarged and nonenlarged groups, although the nonenlarged group tended to exhibit higher Lysholm score and lesser instability. Bone tunnel enlargement of the femoral or tibial side was observed in half of patients (6 in both sides, 5 only in the femur, and 4 only in the tibia) after ACL reconstruction was performed with a hamstring tendon fixed with an RCI screw. Female patients had a greater chance for enlargement of the femoral tunnel

  13. Radiographic predictors of symptomatic screw removal after retrograde femoral nail insertion.

    PubMed

    Hamaker, Max; O'Hara, Nathan N; Eglseder, W Andrew; Sciadini, Marcus F; Nascone, Jason W; O'Toole, Robert V

    2017-03-01

    Removal of symptomatic implants is a common procedure performed by orthopaedic trauma surgeons. No guidance is available regarding which factors contribute to the likelihood of an implant becoming symptomatic. Our objective was to determine whether radiographic parameters associated with distal interlocks in retrograde femoral nails are associated with the rate of symptomatic screw removal. We conducted a retrospective review at a Level I trauma center. Study patients (n=442) had femoral fractures treated with retrograde intramedullary nails from 2007 to 2014 and at least 1year of follow-up. The main outcome measurement was symptomatic distal screw removal as predicted by radiographic parameters. Symptomatic screw removal occurred in 12% of the patients. Increased distance between the most distal screw and the articular surface of the femur significantly reduced likelihood of symptomatic screw removal. A cutoff of 40mm from the articular block was predictive of removal (≥40mm, 0% removal; <40mm, 18% removal, p<0.0001). In patients with distal screws placed within 40mm of the articular surface of the femur, a ratio of screw length to distance between medial and lateral femoral cortices that was ≥1 was a strong predictor of symptomatic screw removal (area under Receiver Operating Characteristic curve, 0.75; p<0.0001). More distal screws and screws that radiographically extend to or beyond the medial cortex are more likely to cause pain and require removal in femoral fractures treated with retrograde intramedullary nails. We identified a specific distance from the joint (<40mm) and a ratio of screw length to bone width (≥1) that significantly increased the likelihood of symptomatic screw removal. Clinicians can use these data to inform patients of the likely risk of implant removal and perhaps to better guide placement and length of screws when the clinical scenario allows some flexibility in location and length of screws. Copyright © 2017 Elsevier Ltd. All

  14. Isolated olecranon fractures in children affected by osteogenesis imperfecta type I treated with single screw or tension band wiring system: Outcomes and pitfalls in relation to bone mineral density.

    PubMed

    Persiani, Pietro; Ranaldi, Filippo M; Graci, Jole; De Cristo, Claudia; Zambrano, Anna; D'Eufemia, Patrizia; Martini, Lorena; Villani, Ciro

    2017-05-01

    The purpose of this study is to compare the results of 2 techniques, tension band wiring (TBW) and fixation with screws, in olecranon fractures in children affected with osteogenesis imperfecta (OI) type I. Between 2010 and 2014, 21 olecranon fractures in 18 children with OI (average age: 12 years old) were treated surgically. Ten patients were treated with the screw fixation and 11 with TBW. A total of 65% of olecranon fractures occurred as a result of a spontaneous avulsion of the olecranon during the contraction of the triceps muscle. The average follow-up was 36 months. Among the children treated with 1 screw, 5 patients needed a surgical revision with TBW due to a mobilization of the screw. In this group, the satisfactory results were 50%. In patients treated with TBW, the satisfactory results were 100% of the cases. The average Z-score, the last one recorded in the patients before the trauma, was -2.53 in patients treated with screw fixation and -2.04 in those treated with TBW. TBW represents the safest surgical treatment for patients suffering from OI type I, as it helps to prevent the rigidity of the elbow through an earlier recovery of the range of motion, and there was no loosening of the implant. In analyzing the average Z-score before any fracture, the fixation with screws has an increased risk of failure in combination with low bone mineral density.

  15. Outcomes of proximal humeral fracture fixation with locked CFR-PEEK plating.

    PubMed

    Katthagen, Jan Christoph; Ellwein, Alexander; Lutz, Olga; Voigt, Christine; Lill, Helmut

    2017-04-01

    To investigate the outcomes of proximal humeral fracture (PHF) fixation with a novel carbon-fiber-reinforced (CFR)-PEEK plate and to compare results with outcomes after conventional locked titanium plating. Twenty-one patients (7 male, 14 female) with operative treatment of unilateral displaced PHFs (mean age, 66.8 ± 9.9 years) with a novel CRF-PEEK plate were prospectively enrolled. Patients were followed up clinically (Constant Score, Simple Shoulder Test and Simple Shoulder Value) and radiologically 3 months postoperative and again clinically 12 months postoperative. Implant-related complications were evaluated after 3 and 12 months. Results at 1-year follow-up were compared with results of 21 patients (7 male, 14 female; mean age, 67.4 ± 9.7 years) with conventional titanium locked plating by matched case-control analysis. All functional outcomes improved after CFR-PEEK plating (p < 0.05). Twelve months postoperatively, the mean age- and gender-related Constant Score was 99.8 ± 21.2%. All fractures healed by the 3-month follow-up without evidence of secondary screw perforation, fragment displacement or loss of fixation. There were no significant differences between the functional outcomes of patients with the CF-PEEK plate and patients with locked titanium plating (p > 0.05). Patients with locked titanium plating were significantly more likely to require revision surgery related to articular screw perforations (p = 0.048). Fracture fixation of displaced PHFs with a novel CFR-PEEK plate resulted in good to excellent 1-year functional outcomes which were similar to outcomes of conventional locked titanium plating. The stiffer locked titanium plating was associated with a higher risk of articular screw perforations than the more elastic CFR-PEEK plate.

  16. [Three-dimensional finite element analysis of three conjunctive methods of free iliac bone graft for established mandibular body defects].

    PubMed

    Wang, Dong; Yang, Zhuang-qun; Hu, Xiao-yi

    2007-08-01

    To analyze the stress and displacement distribution of 3D-FE models in three conjunctive methods of vascularized iliac bone graft for established mandibular body defects. Using computer image process technique, a series of spiral CT images were put into Ansys preprocess programe to establish three 3D-FE models of different conjunctions. The three 3D-FE models of established mandibular body defects by vascularized iliac bone graft were built up. The distribution of Von Mises stress and displacement around mandibular segment, grafted ilium, plates and screws was obtained. It may be determined successfully that the optimal conjunctive shape be the on-lay conjunction.

  17. Possible Vascular Injury Due to Screw Eccentricity in Minimally Invasive Total Hip Arthroplasty

    PubMed Central

    Singh, Nishant Kumar; Rai, Sanjay Kumar; Rastogi, Amit

    2017-01-01

    Background: Vascular injury during minimally invasive total hip arthroplasty (THA) is uncommon, yet a well-recognized and serious issue. It emerges because of non-visibility of vascular structures proximal to the pelvic bone during reaming, drilling holes, and fixing of screws. Numerous studies have found that screw fixation during cementless THA is beneficial for the initial stability of cup; yet, no anatomical guidelines support angular eccentric screw fixation. Materials and Methods: In this study, we obtained the pelvic arterial-phase computed tomographic data of thirty eight humans and reconstructed the three-dimensional models of osseous and vessel structures. We performed the surgical simulation to fix these structures with cementless cups and screws with angular eccentricities. Results: The effect of screw eccentricities (angular eccentricities of ±17° and ±34°) on the vascular injury was determined. Measurement between screw and adjoining vessels was performed and analyzed statistically to ascertain a comparative risk study for blood vessels that are not visible during surgery. Conclusion: Authors similarly discussed the significant absence of appreciation of quadrant systems proposed by Wasielewski et al. on eccentric screws. Adjustment of quadrant systems provided by Wasielewski et al. is required for acetabular implants with eccentric holes for fixation of acetabular screws. PMID:28790474

  18. Biomechanical assessment and 3D finite element analysis of the treatment of tibial fractures using minimally invasive percutaneous plates

    PubMed Central

    Hu, Xin-Jia; Wang, Hua

    2017-01-01

    The aim of the present study was to investigate the biomechanical effects of varying the length of a limited contact-dynamic compression plate (LC-DCP) and the number and position of screws on middle tibial fractures, and to provide biomechanical evidence regarding minimally invasive plate osteosynthesis (MIPO). For biomechanical testing, 60 tibias from cadavers (age at mortality, 20–40 years) were used to create middle and diagonal fracture models without defects. Tibias were randomly grouped and analyzed by biomechanic and three-dimensional (3D) finite element analysis. The differences among LC-DCPs of different lengths (6-, 10- and 14-hole) with 6 screws, 14-hole LC-DCPs with different numbers of screws (6, 10 and 14), and 14-hole LC-DCPs with 6 screws at different positions with regard to mechanical characteristics, including compressing, torsion and bending, were examined. The 6-hole LC-DCP had greater vertical compression strain compared with the 10- and 14-hole LC-DCPs (P<0.01), and the 14-hole LC-DCP had greater lateral strain than the 6- and 10-hole LC-DCPs (P<0.01). Furthermore, significant differences in torque were observed among the LC-DPs of different lengths (P<0.01). For 14-hole LC-DCPs with different numbers of screws, no significant differences in vertical strain, lateral strain or torque were detected (P>0.05). However, plates with 14 screws had greater vertical strain compared with those fixed with 6 or 10 screws (P<0.01). For 4-hole LC-DCPs with screws at different positions, vertical compression strain values were lowest for plates with screws at positions 1, 4, 7, 8, 11 and 14 (P<0.01). The lateral strain values and vertical strain values for plates with screws at positions 1, 3, 6, 9, 12 and 14 were significantly lower compared with those at the other positions (P<0.01), and torque values were also low. Thus, the 14-hole LC-DCP was the most stable against vertical compression, torsion and bending, and the 6-hole LC-DCP was the least stable

  19. The effect of screw taper on interference fit during load to failure at the soft tissue/bone interface.

    PubMed

    Mann, Charles J; Costi, John J; Stanley, Richard M; Dobson, Peter J

    2005-10-01

    The effect of screw geometry on the pullout strength of an anterior cruciate ligament reconstruction is well documented. The effect of a truly tapered screw has not been previously investigated. Thirty bovine knees in right and left knee pairs were collected. Superficial digital flexors from the hind legs of sheep were harvested to form a quadruple tendon graft. For each knee pair, one tendon graft was fixed using a tapered screw (n=15) and the other with a non-tapered screw (n=15). Interference screws were manufactured from stainless steel, and apart from the tapered or non-tapered profile were identical. The screws were inserted into a tibial tunnel already containing the tendon graft. The interference fit was tested by extensile load to failure tests. The insertion torque of the screws and first sign of load to failure (by pullout) of the interference fit were recorded. Results were analysed using paired t-tests. The results indicated that tapered screws have significantly higher resistance to interference failure (p=0.007) and insertion torque (p<0.001) than non-tapered screws. The improved biomechanical performance of tapered screws demonstrated in this study may translate into superior clinical results, particularly at the tibial attachment of hamstring anterior cruciate ligament reconstruction, and also of hamstring fixation to the medial femoral condyle for patella instability.

  20. Biomechanical analysis using FEA and experiments of a standard plate method versus three cable methods for fixing acetabular fractures with simultaneous THA.

    PubMed

    Aziz, Mina S R; Dessouki, Omar; Samiezadeh, Saeid; Bougherara, Habiba; Schemitsch, Emil H; Zdero, Radovan

    2017-08-01

    Acetabular fractures potentially account for up to half of all pelvic fractures, while pelvic fractures potentially account for over one-tenth of all human bone fractures. This is the first biomechanical study to assess acetabular fracture fixation using plates versus cables in the presence of a total hip arthroplasty, as done for the elderly. In Phase 1, finite element (FE) models compared a standard plate method versus 3 cable methods for repairing an acetabular fracture (type: anterior column plus posterior hemi-transverse) subjected to a physiological-type compressive load of 2207N representing 3 x body weight for a 75kg person during walking. FE stress maps were compared to choose the most mechanically stable cable method, i.e. lowest peak bone stress. In Phase 2, mechanical tests were then done in artificial hemipelvises to compare the standard plate method versus the optimal cable method selected from Phase 1. FE analysis results showed peak bone stresses of 255MPa (Plate method), 205MPa (Mears cable method), 250MPa (Kang cable method), and 181MPa (Mouhsine cable method). Mechanical tests then showed that the Plate method versus the Mouhsine cable method selected from Phase 1 had higher stiffness (662versus 385N/mm, p=0.001), strength (3210versus 2060N, p=0.009), and failure energy (8.8versus 6.2J, p=0.002), whilst they were statistically equivalent for interfragmentary sliding (p≥0.179) and interfragmentary gapping (p≥0.08). The Plate method had superior mechanical properties, but the Mouhsine cable method may be a reasonable alternative if osteoporosis prevents good screw thread interdigitation during plating. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Arthrodesis of the first metatarsophalangeal joint using a dorsal titanium contoured plate.

    PubMed

    Flavin, Robert; Stephens, Michael M

    2004-11-01

    Arthrodesis of the first metatarsophalangeal joint (MTPJ) is used to treat a variety of foot pathologies. Numerous methods of internal fixation and bone end preparation have been reported. In an effort to bring together the best features of the various internal fixation devices, a low-profile contoured titanium plate (LPCT) using a compression screw was designed to be used with a ball-and-socket bone end preparation. A prospective study was carried out to determine the efficacy of this technique. First MTPJ arthrodesis using an LPCT was done in 12 patients (10 women and two men) either as an isolated procedure (seven patients) or in conjunction with other forefoot procedures (five patients). The changes in the level of pain and activities of daily living were evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) hallux score and the Short-Form 36 (SF-36) score. Time to bone union also was assessed. Mean followup was 18 months (+/-6 months). Statistically significant increases in the AOFAS hallux score and the SF-36 score were noted (p = .002 and .001, respectively). All radiographs showed bone union at 6 weeks and an appropriate degree of hallux dorsiflexion in relation to the first metatarsal (20 to 25 degrees). The combination of the LPCT plate and a ball-and-socket bone-end preparation has both operative and biomechanical advantages over other fixation techniques. This combination ensures that the anatomical length of the first ray is only minimally shortened and the angle of plantarflexion of the first metatarsal is maintained, resulting in preservation of medial column stability and a better functional result.

  2. Tendon transfer fixation: comparing a tendon to tendon technique vs. bioabsorbable interference-fit screw fixation.

    PubMed

    Sabonghy, Eric Peter; Wood, Robert Michael; Ambrose, Catherine Glauber; McGarvey, William Christopher; Clanton, Thomas Oscar

    2003-03-01

    Tendon transfer techniques in the foot and ankle are used for tendon ruptures, deformities, and instabilities. This fresh cadaver study compares the tendon fixation strength in 10 paired specimens by performing a tendon to tendon fixation technique or using 7 x 20-25 mm bioabsorbable interference-fit screw tendon fixation technique. Load at failure of the tendon to tendon fixation method averaged 279N (Standard Deviation 81N) and the bioabsorbable screw 148N (Standard Deviation 72N) [p = 0.0008]. Bioabsorbable interference-fit screws in these specimens show decreased fixation strength relative to the traditional fixation technique. However, the mean bioabsorbable screw fixation strength of 148N provides physiologic strength at the tendon-bone interface.

  3. Neurotrophin-3 Induces BMP-2 and VEGF Activities and Promotes the Bony Repair of Injured Growth Plate Cartilage and Bone in Rats.

    PubMed

    Su, Yu-Wen; Chung, Rosa; Ruan, Chun-Sheng; Chim, Shek Man; Kuek, Vincent; Dwivedi, Prem P; Hassanshahi, Mohammadhossein; Chen, Ke-Ming; Xie, Yangli; Chen, Lin; Foster, Bruce K; Rosen, Vicki; Zhou, Xin-Fu; Xu, Jiake; Xian, Cory J

    2016-06-01

    Injured growth plate is often repaired by bony tissue causing bone growth defects, for which the mechanisms remain unclear. Because neurotrophins have been implicated in bone fracture repair, here we investigated their potential roles in growth plate bony repair in rats. After a drill-hole injury was made in the tibial growth plate and bone, increased injury site mRNA expression was observed for neurotrophins NGF, BDNF, NT-3, and NT-4 and their Trk receptors. NT-3 and its receptor TrkC showed the highest induction. NT-3 was localized to repairing cells, whereas TrkC was observed in stromal cells, osteoblasts, and blood vessel cells at the injury site. Moreover, systemic NT-3 immunoneutralization reduced bone volume at injury sites and also reduced vascularization at the injured growth plate, whereas recombinant NT-3 treatment promoted bony repair with elevated levels of mRNA for osteogenic markers and bone morphogenetic protein (BMP-2) and increased vascularization and mRNA for vascular endothelial growth factor (VEGF) and endothelial cell marker CD31 at the injured growth plate. When examined in vitro, NT-3 promoted osteogenesis in rat bone marrow stromal cells, induced Erk1/2 and Akt phosphorylation, and enhanced expression of BMPs (particularly BMP-2) and VEGF in the mineralizing cells. It also induced CD31 and VEGF mRNA in rat primary endothelial cell culture. BMP activity appears critical for NT-3 osteogenic effect in vitro because it can be almost completely abrogated by co-addition of the BMP inhibitor noggin. Consistent with its angiogenic effect in vivo, NT-3 promoted angiogenesis in metatarsal bone explants, an effect abolished by co-treatment with anti-VEGF. This study suggests that NT-3 may be an osteogenic and angiogenic factor upstream of BMP-2 and VEGF in bony repair, and further studies are required to investigate whether NT-3 may be a potential target for preventing growth plate faulty bony repair or for promoting bone fracture healing. © 2016

  4. In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables.

    PubMed

    Hitchon, Patrick W; Brenton, Matthew D; Black, Andrew G; From, Aaron; Harrod, Jeremy S; Barry, Christopher; Serhan, Hassan; Torner, James C

    2003-07-01

    Three types of posterior thoracolumbar implants are in use today: pedicle screws, sublaminar titaniumcables, and sublaminar hooks. The authors conducted a biomechanical comparison of these three implants in human cadaveric spines. Spine specimens (T5-12) were harvested, radiographically assessed for fractures or metastases, and their bone mineral density (BMD) was measured. Individual vertebrae were disarticulated and fitted with either pedicle screws, sublaminar cables, or bilateral claw hooks. The longitudinal component of each construct consisted of bilateral 10-cm rods connected with two cross-connectors. The vertebral body was embedded in cement, and the rods were affixed to a ball-and-socket apparatus for the application of a distraction force. The authors analyzed 1) 20 vertebrae implanted with screws; 2) 20 with hooks, and 3) 20 with cables. The maximum pullout (MPO) forces prior to failure (mean +/- standard deviation) for the screw, hook, and cable implants were 972 +/- 330, 802 +/- 356, and 654 +/- 248 N, respectively (p = 0.0375). Cables allowed significantly greater displacement (6.80 +/- 3.95 mm) prior to reaching the MPO force than hooks (3.73 +/- 1.42 mm) and screws (4.42 +/- 2.15 mm [p = 0.0108]). Eleven screw-implanted vertebrae failed because of screw pullout. All hook-and-cable-implanted vertebrae failed because of pedicle, middle column, or laminar fracture. These findings suggest that screws possess the greatest pullout strength of the three fixation systems. Sublaminar cables are the least rigid of the three. When screw failure occurred, the mechanism was generally screw back-out, without vertebral fractures.

  5. Immediate prosthesis over implants retained using abutments with flexible screws: A preliminary study

    PubMed Central

    Peñarrocha-Oltra, David; Serra-Pastor, Blanca; Balaguer-Martí, José-Carlos; Agustín-Panadero, Rubén

    2017-01-01

    Background Immediate loading protocols for the rehabilitation of edentulous or partially edentulous patients have become very popular, due to the conveniences they afford in comparison with conventional loading techniques. Material and Methods A preliminary study was carried out with 8 patients subjected to dental implant treatment with an immediate loading protocol involving a novel system of abutments with flexible screws. Implant survival was analyzed, together with marginal bone loss and patient and dentist satisfaction. Results A total of 35 implants were subjected to immediate loading using the abutments with flexible screws. The mean patient and dentist satisfaction score was 9.1 and 8.5, respectively. After 12 months the dental implant survival rate was 95.8%, with a mean marginal bone loss of 0.51 ± 0.12 mm. Conclusions The novel system of abutments with flexible screws offers a good alternative to conventional immediate loading, since it allows rapid and simple manufacture of a reliable passive fit, fixed interim prosthesis after surgery. Key words:Dental implants, Flexafit®, Immediate loading, Immediate prosthesis. PMID:29410752

  6. Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading.

    PubMed

    Lindtner, Richard A; Schmid, Rene; Nydegger, Thomas; Konschake, Marko; Schmoelz, Werner

    2018-03-01

    Pedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws. In the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm 3  ± 14.5) were randomly instrumented with either CF/PEEK or standard titanium pedicle screws. In the second part, left and right pedicles of ten vertebrae (BMD 56.3 mg/cm 3  ± 15.8) were randomly instrumented with either PMMA-augmented or nonaugmented CF/PEEK pedicle screws. Each pedicle screw was subjected to cyclic cranio-caudal loading (initial load ranging from - 50 N to + 50 N) with stepwise increasing compressive loads (5 N every 100 cycles) until loosening or a maximum of 10,000 cycles. Angular screw motion ("screw toggling") within the vertebra was measured with a 3D motion analysis system every 100 cycles and by stress fluoroscopy every 500 cycles. The nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard

  7. Second generation locked plating for complex proximal humerus fractures in very elderly patients.

    PubMed

    Gavaskar, Ashok S; Karthik B, Bhupesh; Tummala, Naveen C; Srinivasan, Parthasarathy; Gopalan, Hitesh

    2016-11-01

    Humeral head sacrificing procedures are more favored in elderly patients with complex proximal humerus fractures because of high incidence of failures and complications with osteosynthesis. The purpose of this study is to assess the outcome of second generation locked plating techniques in 3 and 4 part fractures in active elderly patients >70years with an emphasis on function and complications. 29 patients with displaced 3 and 4 part proximal humerus fractures were treated using the principles of second-generation proximal humerus locked plating. Fixed angle locked plating (PHILOS) using the anterolateral deltoid spilt approach augmented with traction cuff sutures was performed. Minimum of 7 locking head screws including 2 calcar screws were used. In cases with a comminuted medial calcar, an endosteal fibular strut was used. Subchondral metaphyseal bone voids were filled with injectable calcium phosphate cement. Radiological outcome (union, head - shaft angle, tuberosity reduction), functional outcome assessment (Constant and ASES scores) and complications (loss of reduction, nonunion and osteonecrosis) were assessed. The fracture united in 24 of the 26 patients available for follow up at a mean of 27 months (12-40 months). 3 patients developed complications that required arthroplasty (fixation failure in 2 patients and osteonecrosis in 1 patient). Follow up age adjusted Constant (63.1±11.9) and ASES scores (62.58±7.5) showed the extent of functional improvement post surgery. Patients with fractures having a non-comminuted medial calcar and valgus displacement of the humeral head had better functional scores and fewer complications. Osteosynthesis with second generation locked plating techniques provide satisfactory outcome in very elderly patients with complex proximal humerus fractures with minimal complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Is there any place for the variable angle proximal femoral plate? A case matched cohort study against the Dynamic Hip Screw system.

    PubMed

    Tucker, A; Diamond, O; McDonald, S; Johnston, A; Neil, M; Kealey, D; Archbold, P

    2016-10-01

    The Variable angle Martin Plate (MP) is designed to offer patient-specific adaption for the treatment of intertrochanteric hip fractures. Its proposed benefits include optimization of lag screw placement, plate shaft congruence and reduced risk of failure. Often its use has been criticized as representing a poor reduction of the fracture. The purpose of this study was to assess for a poorer quality of reduction, and compare functional outcomes and mortality, using a MP to that of a fixed angle Dynamic Hip Screw (DHS) in a matched cohort of patients. A retrospective review of a prospective fracture database system was undertaken between 1st January 2004 to 31st December 2013. MP patients were matched to a cohort of DHS patients. Outcomes measure were a quality of procedure score(QPS), 1-year mortality rates, reoperation rates, and Barthel Index functional outcome. Minimum follow up was 12 months. A total of 77 Martin Plate patients were identified and case matched. The mean pre- and post-op Neck Shaft Angle (NSA) in the MPs was significantly different (132.97±7.78 Vs 126±8.62; p<0.0001). Conversely, the mean pre op DHS NSA and the mean post op NSA was not (p=0.397). Mean Tip-Apex Distance (TAD) was significantly different between groups; MP mean 26.51±9.09mm vs DHS 23.50±8.14mm (p=0.023). The QPS consisted of 4 variables. A significant inverse relationship between QPS and the incidence of construct related complications exists. TAD>25mm, and a change in AP NSA of >5°conveyed the greatest risk of complications. No difference occurred in complications, nor 12-month mortality. No statistical difference was found in the quality of reduction between MP and DHS in this group of matched patients. QPS demonstrated a significant inverse correlation with implant-related complications. No significant difference was noted in the incidence of complications, Barthel Index functional scores, or 12-month mortality between implants. A rationale exists regarding the use of MPs

  9. Dynamic Fixation of Humeral Shaft Fractures Using Active Locking Plates: A Prospective Observational Study.

    PubMed

    Madey, Steven M; Tsai, Stanley; Fitzpatrick, Daniel C; Earley, Kathleen; Lutsch, Michael; Bottlang, Michael

    2017-01-01

    Rigid locked plating constructs can suppress fracture healing by inhibiting interfragmentary motion required to stimulate natural bone healing by callus formation. Dynamic fixation with active locking plates reduces construct stiffness, enables controlled interfragmentary motion, and has been shown to induce faster and stronger bone healing in vivo compared to rigid locking plates. This prospective observational study represents the first clinical use of active locking plates. It documents our early clinical experience with active plates for stabilization of humeral shaft fractures to assess their durability and understand potential complications. Eleven consecutive patients with humeral shaft fractures (AO/OTA types 12 A-C) were prospectively enrolled at a level I and a level II trauma center. Fractures were stabilized by using active locking plates without supplemental bone graft or bone morphogenic proteins. The screw holes of active locking plates are elastically suspended in elastomer envelopes inside the plate, enabling up to 1.5 mm of controlled interfragmentary motion. Progression of fracture healing and integrity of implant fixation was assessed radiographically at 3, 6, 12, and 24 weeks post surgery. Patient-reported functional outcome measures were obtained at 6, 12, and 24 weeks post surgery. The primary endpoint of this study was plate durability in absence of plate bending or breakage, or failure of the elastically suspended locking hole mechanism. Secondary endpoints included fracture healing, complications requiring revision surgery, and functional outcome scores. The eleven patients had six simple AO/ OTA type 12A fractures, three wedge type 12B fractures, and two comminuted type 12C fracture, including one open fracture. All active locking plates endured the 6-month loading period without any signs of fatigue or failure. Ten of eleven fractures healed at 10.9 ± 5.2 weeks, as evident by bridging callus and pain-free function. One fracture required

  10. A Novel Murine Model of Established Staphylococcal Bone Infection in the Presence of a Fracture Fixation Plate to Study Therapies Utilizing Antibiotic-laden Spacers after Revision Surgery

    PubMed Central

    Inzana, Jason A.; Schwarz, Edward M.; Kates, Stephen L.; Awad, Hani A.

    2014-01-01

    Mice are the small animal model of choice in biomedical research due to the low cost and availability of genetically engineered lines. However, the devices utilized in current mouse models of implant-associated bone infection have been limited to intramedullary or trans-cortical pins, which are not amenable to treatments involving extensive debridement of a full-thickness bone loss and placement of a segmental antibiotic spacer. To overcome these limitations, we developed a clinically faithful model that utilizes a locking fracture fixation plate to enable debridement of an infected segmental bone defect (full-thickness osteotomy) during a revision surgery, and investigated the therapeutic effects of placing an antibiotic-laden spacer in the segmental bone defect. To first determine the ideal time point for revision following infection, a 0.7 mm osteotomy in the femoral mid-shaft was stabilized with a radiolucent PEEK fixation plate. The defect was inoculated with bioluminescent Staphylococcus aureus, and the infection was monitored over 14 days by bioluminescent imaging (BLI). Osteolysis and reactive bone formation were assessed by X-ray and micro-computed tomography (micro-CT). The active bacterial infection peaked by 5 days post-inoculation, however the stability of the implant fixation became compromised by 10–14 days post-inoculation due to osteolysis around the screws. Thus, day 7 was defined as the ideal time point to perform the revision surgery. During the revision surgery, the infected tissue was debrided and the osteotomy was widened to 3 mm to place a poly-methyl methacrylate spacer, with or without vancomycin. Half of the groups also received systemic vancomycin for the remaining 21 days of the study. The viable bacteria remaining at the end of the study were measured using colony forming unit assays. Volumetric bone changes (osteolysis and reactive bone formation) were directly measured using micro-CT image analysis. Mice that were treated with

  11. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures.

    PubMed

    Sohn, Hoon-Sang; Kim, Won Ju; Shon, Min Soo

    2015-08-01

    Current literatures describe good clinical outcomes of acute displaced fracture of clavicle treated with minimally invasive plate osteosynthesis (MIPO). But, there are little comparative data of the outcomes between open plating and MIPO techniques. We compared the outcomes of open plating and MIPO for treatment of acute displaced clavicular shaft fractures. The author performed a retrospective review on a consecutive series of patients with clavicular shaft fracture who underwent open plating or MIPO. Fourteen patients were treated with open plating with interfragmentary screw fixation, and 19 were treated with the MIPO technique without exposing a fracture site itself. A superior plating method was applied to both groups. Patient demographics, clinical outcomes using Constant score and University of California Los Angeles (UCLA) shoulder score, operation time, union rate, complications, and radiographic evaluation were evaluated. There were no statistically significant differences in the demographic data, including patient's variables (age, gender, involved side, smoking, alcohol, and diabetic status) and fracture characteristics (trauma mechanism, distribution of fracture type, presence of polytrauma, and time from trauma to surgery) between the two groups. Mean operation time was 87.5 min in open plating and 77.2 min in MIPO (p=0.129). The mean time to union was 15.7 weeks in patients who underwent open plating and 16.8 weeks in patients who underwent MIPO (p=0.427). Although there was no significant difference, nonunion developed 1 case in MIPO while none was in open plating. Four patients in open plating had skin numbness (none in MIPO, p=0.024). There was no significant difference in the Constant score and UCLA score of the two surgical methods. This study showed that both open plating with interfragmentary screw fixation (Open plating) and minimally invasive plate osteosynthesis (MIPO) are equally effective and safe treatment methods for acute displaced

  12. Computed tomography assessment of lateral pedicle wall perforation by free-hand subaxial cervical pedicle screw placement.

    PubMed

    Wang, Yingsong; Xie, Jingming; Yang, Zhendong; Zhao, Zhi; Zhang, Ying; Li, Tao; Liu, Luping

    2013-07-01

    To present the technique of free-hand subaxial cervical pedicle screw (CPS) placement without using intra-operative navigating devices, and to investigate the crucial factors for safe placement and avoidance of lateral pedicle wall perforation, by measuring and classifying perforations with postoperative computed tomography (CT) scan. The placement of CPS has generally been considered as technically demanding and associated with considerable lateral wall perforation rate. For surgeons without access to navigation systems, experience of safe free-hand technique for subaxial CPS placement is especially valuable. A total of 214 consecutive traumatic or degenerative patients with 1,024 CPS placement using the free-hand technique were enrolled. In the operative process, the lateral mass surface was decorticated. Then a small curette was used to identify the pedicle entrance by touching the cortical bone of the medial pedicle wall. It was crucial to keep the transverse angle and make appropriate adjustment with guidance of the resistance of the thick medial cortical bone. The hand drill should be redirected once soft tissue breach was palpated by a slim ball-tip prober. With proper trajectory, tapping, repeated palpation, the 26-30 mm screw could be placed. After the procedure, the transverse angle of CPS trajectory was measured, and perforation of the lateral wall was classified by CT scan: grade 1, perforation of pedicle wall by screw placement, with the external edge of screw deviating out of the lateral pedicle wall equal to or less than 2 mm and grade 2, critical perforation of pedicle wall by screw placement, large than 2 mm. A total of 129 screws (12.64 %) were demonstrated as lateral pedicle wall perforation, of which 101 screws (9.86 %) were classified as grade 1, whereas 28 screws (2.73 %) as grade 2. Among the segments involved, C3 showed an obviously higher perforating rate than other (P < 0.05). The difference between the anatomical pedicle transverse angle

  13. Screw-locking wrench

    NASA Technical Reports Server (NTRS)

    Vranish, John M. (Inventor)

    2007-01-01

    A tool comprises a first handle and a second handle, each handle extending from a gripping end portion to a working end portion, the first handle having first screw threads disposed circumferentially about an inner portion of a first through-hole at the working end portion thereof, the second handle having second screw threads disposed circumferentially about an inner portion of a second through-hole at the working end portion thereof, the first and second respective through-holes being disposed concentrically about a common axis of the working end portions. First and second screw locks preferably are disposed concentrically with the first and second respective through-holes, the first screw lock having a plurality of locking/unlocking screw threads for engaging the first screw threads of the first handle, the second screw lock having a plurality of locking/unlocking screw threads for engaging the second screw threads of the second handle. A locking clutch drive, disposed concentrically with the first and second respective through-holes, engages the first screw lock and the second screw lock. The first handle and the second handle are selectively operable at their gripping end portions by a user using a single hand to activate the first and second screw locks to lock the locking clutch drive for either clockwise rotation about the common axis, or counter-clockwise rotation about the common axis, or to release the locking clutch drive so that the handles can be rotated together about the common axis either the clockwise or counter-clockwise direction without rotation of the locking clutch drive.

  14. The outcome of unstable proximal femoral fracture treated with reverse LISS plates.

    PubMed

    Lin, Shih-Jie; Huang, Kuo-Chin; Chuang, Po-Yao; Lee, Chien-Yin; Huang, Tsan-Wen; Lee, Mel S; Hsu, Robert Wen-Wei

    2016-10-01

    The Russel-Taylor type 2B fractures compromised the trochanteric region and medial buttress of proximal femur. This fracture pattern limits the choice of implants and raises the risk of adverse outcomes. We aimed to (i) determine the outcome of Russel-Taylor type 2B fractures treated using reverse less invasive stabilization system plates (LISS-DF) and to (ii) learn what factors affected outcomes after osteosynthesis with reverse LISS plates. A retrospective study SETTING: The study was conducted at a Level III trauma center in Taiwan. Twenty-five consecutive patients presenting with a Russel-Taylor type 2B fracture were enrolled. All cases were treated with reverse LISS plates. A Modified Radiographic Union Scale for Femur (RUSF), Radiographic parameters, functional scores, and complications were assessed. Union occurred in 21 cases at an average of 18.8 weeks. The average immediate postoperative neck-shaft angle was 130° (range: 122-135°) compared with 139° (range: 135-141°, p=0.05) on the contralateral side. Two cases had complications of proximal screws cutting out and two cases had broken implants. Finally, all 4 cases required repeated surgeries (16%). Malunion occurred in 4 patients and early mechanical failure (proximal screws cut out) occurred in 2. There was a significant difference in the purchase index of the proximal screws between cases with redisplacement and those without (26.4mm and 98.6mm, p=0.01). The use of reverse LISS plate appeared to be an alternative procedure for the specific pattern in the present study. We recommend using this reverse locking plate to treat unstable proximal femoral fractures with meticulous techniques of placing plates. Adequate purchase of the proximal locking screws might decrease the risks of complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Central tarsal bone fractures in horses not used for racing: Computed tomographic configuration and long-term outcome of lag screw fixation.

    PubMed

    Gunst, S; Del Chicca, F; Fürst, A E; Kuemmerle, J M

    2016-09-01

    There are no reports on the configuration of equine central tarsal bone fractures based on cross-sectional imaging and clinical and radiographic long-term outcome after internal fixation. To report clinical, radiographic and computed tomographic findings of equine central tarsal bone fractures and to evaluate the long-term outcome of internal fixation. Retrospective case series. All horses diagnosed with a central tarsal bone fracture at our institution in 2009-2013 were included. Computed tomography and internal fixation using lag screw technique was performed in all patients. Medical records and diagnostic images were reviewed retrospectively. A clinical and radiographic follow-up examination was performed at least 1 year post operatively. A central tarsal bone fracture was diagnosed in 6 horses. Five were Warmbloods used for showjumping and one was a Quarter Horse used for reining. All horses had sagittal slab fractures that began dorsally, ran in a plantar or plantaromedial direction and exited the plantar cortex at the plantar or plantaromedial indentation of the central tarsal bone. Marked sclerosis of the central tarsal bone was diagnosed in all patients. At long-term follow-up, 5/6 horses were sound and used as intended although mild osteophyte formation at the distal intertarsal joint was commonly observed. Central tarsal bone fractures in nonracehorses had a distinct configuration but radiographically subtle additional fracture lines can occur. A chronic stress related aetiology seems likely. Internal fixation of these fractures based on an accurate diagnosis of the individual fracture configuration resulted in a very good prognosis. © 2015 EVJ Ltd.

  16. Comparison of calcaneal fixation of a retrograde intramedullary nail with a fixed-angle spiral blade versus a fixed-angle screw.

    PubMed

    Klos, Kajetan; Gueorguiev, Boyko; Schwieger, Karsten; Fröber, Rosemarie; Brodt, Steffen; Hofmann, Gunther O; Windolf, Markus; Mückley, Thomas

    2009-12-01

    Retrograde intramedullary nailing is an established technique for tibiotalocalcaneal arthrodesis (TTCA). In poor bone stock (osteoporosis, neuroarthropathy), device fixation in the hindfoot remains a problem. Fixed-angle spiral-blade fixation of the nail in the calcaneus could be useful. In seven matched pairs of human below-knee specimens, bone mineral density (BMD) was determined, and TTCA was performed with an intramedullary nail (Synthes Hindfoot Arthrodesis Nail HAN Expert Nailing System), using a conventional screw plus a fixed-angle spiral blade versus a conventional screw plus a fixed-angle screw, in the calcaneus. The constructs were subjected to quasi-static loading (dorsiflexion/plantarflexion, varus/valgus, rotation) and to cyclic loading to failure. Parameters studied were construct neutral zone (NZ) and range of motion (ROM), and number of cycles to failure. With dorsiflexion/plantarflexion loading, the screw-plus-spiral-blade constructs had a significantly smaller ROM in the quasi-static test (p = 0.028) and early in the cyclic test (p = 0.02); differences in the other parameters were not significant. There was a significant correlation between BMD and cycles to failure for the two-screw constructs (r = 0.94; p = 0.002) and for the screw-plus-spiral-blade constructs (r = 0.86; p = 0.014). In TTCA with a HAN Expert Nailing System, the use of a calcaneal spiral blade can further reduce motion within the construct. This may be especially useful in poor bone stock. Results obtained in this study could be used to guide the operating surgeon's TTCA strategy.

  17. Trabecular bone characterization on the continuum of plates and rods using in vivo MR imaging and volumetric topological analysis

    NASA Astrophysics Data System (ADS)

    Chen, Cheng; Jin, Dakai; Liu, Yinxiao; Wehrli, Felix W.; Chang, Gregory; Snyder, Peter J.; Regatte, Ravinder R.; Saha, Punam K.

    2016-09-01

    Osteoporosis is associated with increased risk of fractures, which is clinically defined by low bone mineral density. Increasing evidence suggests that trabecular bone (TB) micro-architecture is an important determinant of bone strength and fracture risk. We present an improved volumetric topological analysis algorithm based on fuzzy skeletonization, results of its application on in vivo MR imaging, and compare its performance with digital topological analysis. The new VTA method eliminates data loss in the binarization step and yields accurate and robust measures of local plate-width for individual trabeculae, which allows classification of TB structures on the continuum between perfect plates and rods. The repeat-scan reproducibility of the method was evaluated on in vivo MRI of distal femur and distal radius, and high intra-class correlation coefficients between 0.93 and 0.97 were observed. The method’s ability to detect treatment effects on TB micro-architecture was examined in a 2 years testosterone study on hypogonadal men. It was observed from experimental results that average plate-width and plate-to-rod ratio significantly improved after 6 months and the improvement was found to continue at 12 and 24 months. The bone density of plate-like trabeculae was found to increase by 6.5% (p  =  0.06), 7.2% (p  =  0.07) and 16.2% (p  =  0.003) at 6, 12, 24 months, respectively. While the density of rod-like trabeculae did not change significantly, even at 24 months. A comparative study showed that VTA has enhanced ability to detect treatment effects in TB micro-architecture as compared to conventional method of digital topological analysis for plate/rod characterization in terms of both percent change and effect-size.

  18. Radiographic and Histological Evaluation of the Healing of Extraction Sockets Filled With Bovine-Derived Xenograft: An Experimental Study in Rats.

    PubMed

    Zhou, Fengjuan; Zheng, Xiaofei; Xie, Meng; Mo, Anchun; Wu, Hongkun

    2017-06-01

    To evaluate the microenvironment changes in the sockets substituted with bovine-derived xenografts during the early healing period. After extraction of the right maxillary incisor of Sprague Dawley rats, 48 rats were randomly divided into 2 groups. The extraction sockets of the test group were filled with Bio-Oss, whereas the control group was allowed to heal without intervention. The bone quality of the extraction sockets was observed through micro-CT and immunohistochemistry. Micro-CT scanning showed that the bone mineral density in the test group was significantly higher than that in the control group during the early healing period, whereas immunohistochemistry showed that the bone formation-related factors were significantly different between the test and control groups. The bovine-derived xenografts may interfere with the healing process of the extraction socket in the early healing stage. Bone formation of the extraction socket was delayed after grafting with bone substitute.

  19. Distance from the growth plate and Its relation to the outcome of unicameral bone cyst treatment.

    PubMed

    Haidar, Saadallah George; Culliford, David J; Gent, Edward David; Clarke, Nicholas M P

    2011-04-01

    Interventions to treat unicameral bone cysts vary. Nonetheless, regardless of the intervention modality, the outcome is not certain. The purpose of this study was to determine if the distance between the growth plate and the cyst can be used to predict the outcome of the treatment. Retrospectively, we assessed the outcome of 39 interventions in nineteen children that were performed between 1994 and 2003. Seventeen different modalities of treatment were employed. There were three female and sixteen male patients. The average age was 8 years. Nine cysts were in the greater trochanter area, three were in the femoral capital area and seven were in the proximal humerus. According to the cyst's distance from the growth plate, at the intervention time, there were 18 cases within less than 2 cm and 21 cases of more than 2 cm. Complete healing was achieved in 10 children (employing seven different modalities). In nine of them, the cysts were more than 2 cm away from the growth plate. In one child, the cyst was within less than 2 cm of the growth plate, however, treatment here involved epiphyseodesis. This study confirmed that, regardless of intervention modality, complete healing was not achievable in those cysts that are within less than 2 cm of an active growth plate. Complete healing was possible in those cysts that are more than 2 cm away from the growth plate. The 2-cm distance from the growth plate could be used as a predictor of treatment outcome of unicameral bone cysts.

  20. Development of a Preclinical Orthotopic Xenograft Model of Ewing Sarcoma and Other Human Malignant Bone Disease Using Advanced In Vivo Imaging

    PubMed Central

    Batey, Michael A.; Almeida, Gilberto S.; Wilson, Ian; Dildey, Petra; Sharma, Abhishek; Blair, Helen; Hide, I. Geoff; Heidenreich, Olaf; Vormoor, Josef; Maxwell, Ross J.; Bacon, Chris M.

    2014-01-01

    Ewing sarcoma and osteosarcoma represent the two most common primary bone tumours in childhood and adolescence, with bone metastases being the most adverse prognostic factor. In prostate cancer, osseous metastasis poses a major clinical challenge. We developed a preclinical orthotopic model of Ewing sarcoma, reflecting the biology of the tumour-bone interactions in human disease and allowing in vivo monitoring of disease progression, and compared this with models of osteosarcoma and prostate carcinoma. Human tumour cell lines were transplanted into non-obese diabetic/severe combined immunodeficient (NSG) and Rag2−/−/γc−/− mice by intrafemoral injection. For Ewing sarcoma, minimal cell numbers (1000–5000) injected in small volumes were able to induce orthotopic tumour growth. Tumour progression was studied using positron emission tomography, computed tomography, magnetic resonance imaging and bioluminescent imaging. Tumours and their interactions with bones were examined by histology. Each tumour induced bone destruction and outgrowth of extramedullary tumour masses, together with characteristic changes in bone that were well visualised by computed tomography, which correlated with post-mortem histology. Ewing sarcoma and, to a lesser extent, osteosarcoma cells induced prominent reactive new bone formation. Osteosarcoma cells produced osteoid and mineralised “malignant” bone within the tumour mass itself. Injection of prostate carcinoma cells led to osteoclast-driven osteolytic lesions. Bioluminescent imaging of Ewing sarcoma xenografts allowed easy and rapid monitoring of tumour growth and detection of tumour dissemination to lungs, liver and bone. Magnetic resonance imaging proved useful for monitoring soft tissue tumour growth and volume. Positron emission tomography proved to be of limited use in this model. Overall, we have developed an orthotopic in vivo model for Ewing sarcoma and other primary and secondary human bone malignancies, which