Sample records for xp pulsed power

  1. The influence of DNA repair on neurological degeneration, cachexia, skin cancer and internal neoplasms: autopsy report of four xeroderma pigmentosum patients (XP-A, XP-C and XP-D)

    PubMed Central

    2013-01-01

    Background To investigate the association of DNA nucleotide excision repair (NER) defects with neurological degeneration, cachexia and cancer, we performed autopsies on 4 adult xeroderma pigmentosum (XP) patients with different clinical features and defects in NER complementation groups XP-A, XP-C or XP-D. Results The XP-A (XP12BE) and XP-D (XP18BE) patients exhibited progressive neurological deterioration with sensorineural hearing loss. The clinical spectrum encompassed severe cachexia in the XP-A (XP12BE) patient, numerous skin cancers in the XP-A and two XP-C (XP24BE and XP1BE) patients and only few skin cancers in the XP-D patient. Two XP-C patients developed internal neoplasms including glioblastoma in XP24BE and uterine adenocarcinoma in XP1BE. At autopsy, the brains of the 44 yr XP-A and the 45 yr XP-D patients were profoundly atrophic and characterized microscopically by diffuse neuronal loss, myelin pallor and gliosis. Unlike the XP-A patient, the XP-D patient had a thickened calvarium, and the brain showed vacuolization of the neuropil in the cerebrum, cerebellum and brainstem, and patchy Purkinje cell loss. Axonal neuropathy and chronic denervation atrophy of the skeletal muscles were observed in the XP-A patient, but not in the XP-D patient. Conclusions These clinical manifestations and autopsy findings indicate advanced involvement of the central and peripheral nervous system. Despite similar defects in DNA repair, different clinicopathological phenotypes are seen in the four cases, and therefore distinct patterns of neurodegeneration characterize XP-D, XP-A and XP-C patients. PMID:24252196

  2. Variable-pulse-shape pulsed-power accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoltzfus, Brian S.; Austin, Kevin; Hutsel, Brian Thomas

    A variable-pulse-shape pulsed-power accelerator is driven by a large number of independent LC drive circuits. Each LC circuit drives one or more coaxial transmission lines that deliver the circuit's output power to several water-insulated radial transmission lines that are connected in parallel at small radius by a water-insulated post-hole convolute. The accelerator can be impedance matched throughout. The coaxial transmission lines are sufficiently long to transit-time isolate the LC drive circuits from the water-insulated transmission lines, which allows each LC drive circuit to be operated without being affected by the other circuits. This enables the creation of any power pulsemore » that can be mathematically described as a time-shifted linear combination of the pulses of the individual LC drive circuits. Therefore, the output power of the convolute can provide a variable pulse shape to a load that can be used for magnetically driven, quasi-isentropic compression experiments and other applications.« less

  3. Industrial Applications of Pulsed Power Technology

    NASA Astrophysics Data System (ADS)

    Takaki, Koichi; Katsuki, Sunao

    Recent progress of the industrial applications of pulsed power is reviewed in this paper. Repetitively operated pulsed power generators with a moderate peak power have been developed for industrial applications. These generators are reliable and low maintenance. Development of the pulsed power generators helps promote industrial applications of pulsed power for such things as food processing, medical treatment, water treatment, exhaust gas treatment, ozone generation, engine ignition, ion implantation and others. Here, industrial applications of pulsed power are classified by application for biological effects, for pulsed streamer discharges in gases, for pulsed discharges in liquid or liquid-mixture, and for bright radiation sources.

  4. Petawatt pulsed-power accelerator

    DOEpatents

    Stygar, William A.; Cuneo, Michael E.; Headley, Daniel I.; Ives, Harry C.; Ives, legal representative; Berry Cottrell; Leeper, Ramon J.; Mazarakis, Michael G.; Olson, Craig L.; Porter, John L.; Wagoner; Tim C.

    2010-03-16

    A petawatt pulsed-power accelerator can be driven by various types of electrical-pulse generators, including conventional Marx generators and linear-transformer drivers. The pulsed-power accelerator can be configured to drive an electrical load from one- or two-sides. Various types of loads can be driven; for example, the accelerator can be used to drive a high-current z-pinch load. When driven by slow-pulse generators (e.g., conventional Marx generators), the accelerator comprises an oil section comprising at least one pulse-generator level having a plurality of pulse generators; a water section comprising a pulse-forming circuit for each pulse generator and a level of monolithic triplate radial-transmission-line impedance transformers, that have variable impedance profiles, for each pulse-generator level; and a vacuum section comprising triplate magnetically insulated transmission lines that feed an electrical load. When driven by LTD generators or other fast-pulse generators, the need for the pulse-forming circuits in the water section can be eliminated.

  5. Familial Xp22.33-Xp22.12 deletion delineated by chromosomal microarray analysis causes proportionate short stature.

    PubMed

    Cho, Sung Yoon; Ki, Chang-Seok; Jang, Ja-Hyun; Sohn, Young Bae; Park, Sung Won; Kim, Se Hwa; Kim, Su Jin; Jin, Dong-Kyu

    2012-06-01

    Patients with Xp deletions have short stature and may have some somatic traits typical of Turner syndrome (TS), whereas gonadal function is generally preserved. In most studies of these patients, microsatellites have been used to determine the break point of the Xp deletion. In the present study, we describe the clinical, cytogenetic, and chromosomal microarray (CMA) analysis of a family with an Xp22.33-Xp22.12 deletion. Two female siblings, aged 8 years 9 months and 11 years 10 months, presented with short stature. The older sibling's height (index case) was 137.9 cm (-1.81 SDS) and the younger sibling's height was 118.6 cm (-2.13 SDS). The mother and both daughters had only a short stature; a skeletal survey showed normal findings except for mildly shortened 4th and 5th metacarpal bones. No features of TS were present. The deletion appeared terminal with a breakpoint within Xp22.2 located about 19.9 Mb from the Xp telomere. The deletion contained 102 protein-coding genes. A probe of the end breakage point was located at the 19,908,986th base of the X chromosome, and a probe of the marginal normal region near the breakage point was located at the 19,910,848th base of the X chromosome. Therefore, the breakage point was concluded to be located between these two probes. In summary, we report a familial case of an Xp deletion. The findings of our study may be helpful in further analyzing the phenotypes associated with Xp deletions. Copyright © 2012 Wiley Periodicals, Inc.

  6. Pulsed Power Education

    DTIC Science & Technology

    1983-06-01

    JUN 1983 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Pulsed Power Education 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...1976-2013, and Abstracts of the 2013 IEEE International Conference on Plasma Science. Held in San Francisco, CA on 16-21 June 2013. U.S. Government or...unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 PULSED POWER EDUCATION * M

  7. BICMOS power detector for pulsed Rf power amplifiers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bridge, Clayton D.

    2016-10-01

    A BiCMOS power detector for pulsed radio-frequency power amplifiers is proposed. Given the pulse waveform and a fraction of the power amplifier's input or output signal, the detector utilizes a low-frequency feedback loop to perform a successive approximation of the amplitude of the input signal. Upon completion of the successive approximation, the detector returns 9-bits representing the amplitude of the RF input signal. Using the pulse waveform from the power amplifier, the detector can dynamically adjust the rate of the binary search operation in order to return the updated amplitude information of the RF input signal at least every 1ms.more » The detector can handle pulse waveform frequencies from 50kHz to 10MHz with duty cycles in the range of 5- 50% and peak power levels of -10 to 10dBm. The signal amplitude measurement can be converted to a peak power measurement accurate to within ±0.6dB of the input RF power.« less

  8. Nance-Horan syndrome: localization within the region Xp21.1-Xp22.3 by linkage analysis.

    PubMed

    Stambolian, D; Lewis, R A; Buetow, K; Bond, A; Nussbaum, R

    1990-07-01

    Nance-Horan Syndrome (NHS) or X-linked cataract-dental syndrome (MIM 302350) is a disease of unknown pathogenesis characterized by congenital cataracts and dental anomalies. We performed linkage analysis in three kindreds with NHS by using six RFLP markers between Xp11.3 and Xp22.3. Close linkage was found between NHS and polymorphic loci DXS43 (theta = 0 with lod score 2.89), DXS41 (theta = 0 with lod score 3.44), and DXS67 (theta = 0 with lod score 2.74), defined by probes pD2, p99-6, and pB24, respectively. Recombinations were found with the marker loci DXS84 (theta = .04 with lod score 4.13), DXS143 (theta = .06 with lod score 3.11) and DXS7 (theta = .09 with lod score 1.68). Multipoint linkage analysis determined the NHS locus to be linked completely to DXS41 (lod score = 7.07). Our linkage results, combined with analysis of Xp interstitial deletions, suggest that the NHS locus is located within or close to the Xp22.1-Xp22.2 region.

  9. Nance-Horan syndrome: localization within the region Xp21.1-Xp22.3 by linkage analysis.

    PubMed Central

    Stambolian, D; Lewis, R A; Buetow, K; Bond, A; Nussbaum, R

    1990-01-01

    Nance-Horan Syndrome (NHS) or X-linked cataract-dental syndrome (MIM 302350) is a disease of unknown pathogenesis characterized by congenital cataracts and dental anomalies. We performed linkage analysis in three kindreds with NHS by using six RFLP markers between Xp11.3 and Xp22.3. Close linkage was found between NHS and polymorphic loci DXS43 (theta = 0 with lod score 2.89), DXS41 (theta = 0 with lod score 3.44), and DXS67 (theta = 0 with lod score 2.74), defined by probes pD2, p99-6, and pB24, respectively. Recombinations were found with the marker loci DXS84 (theta = .04 with lod score 4.13), DXS143 (theta = .06 with lod score 3.11) and DXS7 (theta = .09 with lod score 1.68). Multipoint linkage analysis determined the NHS locus to be linked completely to DXS41 (lod score = 7.07). Our linkage results, combined with analysis of Xp interstitial deletions, suggest that the NHS locus is located within or close to the Xp22.1-Xp22.2 region. PMID:1971992

  10. A Tesla-pulse forming line-plasma opening switch pulsed power generator.

    PubMed

    Novac, B M; Kumar, R; Smith, I R

    2010-10-01

    A pulsed power generator based on a high-voltage Tesla transformer which charges a 3.85 Ω/55 ns water-filled pulse forming line to 300 kV has been developed at Loughborough University as a training tool for pulsed power students. The generator uses all forms of insulation specific to pulsed power technology, liquid (oil and water), gas (SF(6)), and magnetic insulation in vacuum, and a number of fast voltage and current sensors are implemented for diagnostic purposes. A miniature (centimeter-size) plasma opening switch has recently been coupled to the output of the pulse forming line, with the overall system comprising the first phase of a program aimed at the development of a novel repetitive, table-top generator capable of producing 15 GW pulses for high power microwave loads. Technical details of all the generator components and the main experimental results obtained during the program and demonstrations of their performance are presented in the paper, together with a description of the various diagnostic tools involved. In particular, it is shown that the miniature plasma opening switch is capable of reducing the rise time of the input current while significantly increasing the load power. Future plans are outlined in the conclusions.

  11. Power pulsing of the CMOS sensor Mimosa 26

    NASA Astrophysics Data System (ADS)

    Kuprash, Oleg

    2013-12-01

    Mimosa 26 is a monolithic active pixel sensor developed by IPHC (Strasbourg) & IRFU (Saclay) as a prototype for the ILC vertex detector studies. The resolution requirements for the ILC tracking detector are very extreme, demanding very low material in the detector, thus only air cooling can be considered. Power consumption has to be reduced as far as possible. The beam structure of the ILC allows the possibility of power pulsing: only for about the 1 ms long bunch train full power is required, and during the 199 ms long pauses between the bunch trains the power can be reduced to a minimum. Not being adapted for the power pulsing, the sensor shows in laboratory tests a good performance under power pulsing. The power pulsing allows to significantly reduce the heating of the chip and divides power consumption approximately by a factor of 6. In this report a summary of power pulsing studies using the digital readout of Mimosa 26 is given.

  12. Xp11.2 translocation renal cell carcinomas in young adults.

    PubMed

    Xu, Linfeng; Yang, Rong; Gan, Weidong; Chen, Xiancheng; Qiu, Xuefeng; Fu, Kai; Huang, Jin; Zhu, Guancheng; Guo, Hongqian

    2015-07-01

    Little is known about the biological behavior of Xp11.2 translocation renal cell carcinomas (RCCs) as few clinical studies have been performed using a large sample size. This study included 103 consecutive young adult patients (age ≤ 45 years) with RCC who underwent partial or radical nephrectomy at our institution from 2008 to 2013. Five patients without complete clinical data were excluded. Of the 98 remaining patients, 16 and 82 patients were included in the Xp11.2 translocation and non-Xp11.2 translocation groups, respectively. Clinicopathologic data were collected, including age, gender, tumor size, laterality, symptoms at diagnosis, surgical procedure, pathologic stage, tumor grade, time of recurrence and death. Xp11.2 translocation RCCs were associated with higher tumor grade and pathologic stage (P < 0.05, Fisher's exact test). During the median follow-up of 36 months (range: 3-71 months), the number of cancer-related deaths was 4 (4.9%) and 3 (18.7%) in the non-Xp11.2 translocation and Xp11.2 translocation groups, respectively. The Kaplan-Meier cancer specific survival curves revealed a significant difference between non-Xp11.2 translocation RCCs and Xp11.2 translocation RCCs in young adults (P = 0.042). Compared with non-Xp11.2 translocation RCCs, the Xp11.2 translocation RCCs seemingly showed a higher tumor grade and pathologic stage and have similar recurrence-free survival rates but poorer cancer-specific survival rates in young adults.

  13. Pulsed Power Design for a Small Repetitively Pulsed Electron Beam Pumped KrF Laser

    DTIC Science & Technology

    2003-06-01

    fusion energy (IFE) requirements for rep-rate, efficiency, durability and cost. We have designed a pulsed power system for the pre-amplifier in the Electra...new advanced pulsed power topology that can meet the fusion energy requirements for durability, repetition rate, and cost. The pulsed power will first

  14. Xp11.2 translocation renal cell carcinoma.

    PubMed

    Armah, Henry B; Parwani, Anil V

    2010-01-01

    Xp11.2 translocation renal cell carcinomas (RCCs), a recently recognized distinct subtype, are rare tumors predominantly reported in young patients. They comprise at least one-third of pediatric RCCs, and only few adult cases have been reported. They are characterized by various translocations involving chromosome Xp11.2, all resulting in gene fusions involving the transcription factor E3 (TFE3) gene. In recent years, at least 6 different Xp11.2 translocation RCCs have been identified and characterized at the molecular level. These include a distinctive RCC that bears a translocation with the identical chromosomal breakpoints (Xp11.2, 17q25) and identical resulting ASPL-TFE3 gene fusion as alveolar soft part sarcoma. They typically have papillary or nested architecture and are composed of cells with voluminous, clear, or eosinophilic cytoplasm. Their most distinctive immunohistochemical feature is nuclear labeling for TFE3 protein. Although only limited data are available so far, they are believed to be rather indolent, but there have been increasing, recent reports of an aggressive clinical course in adult cases. The consistent immunohistochemical staining for TFE3 in all RCC with unusual histology, regardless of patient age, is likely to expand the spectrum of Xp11.2 translocation RCC with respect to age, clinical behavior, and molecular abnormalities.

  15. Low power arcjet thruster pulse ignition

    NASA Technical Reports Server (NTRS)

    Sarmiento, Charles J.; Gruber, Robert P.

    1987-01-01

    An investigation of the pulse ignition characteristics of a 1 kW class arcjet using an inductive energy storage pulse generator with a pulse width modulated power converter identified several thruster and pulse generator parameters that influence breakdown voltage including pulse generator rate of voltage rise. This work was conducted with an arcjet tested on hydrogen-nitrogen gas mixtures to simulate fully decomposed hydrazine. Over all ranges of thruster and pulser parameters investigated, the mean breakdown voltages varied from 1.4 to 2.7 kV. Ignition tests at elevated thruster temperatures under certain conditions revealed occasional breakdowns to thruster voltages higher than the power converter output voltage. These post breakdown discharges sometimes failed to transition to the lower voltage arc discharge mode and the thruster would not ignite. Under the same conditions, a transition to the arc mode would occur for a subsequent pulse and the thruster would ignite. An automated 11 600 cycle starting and transition to steady state test demonstrated ignition on the first pulse and required application of a second pulse only two times to initiate breakdown.

  16. Prefire identification for pulse-power systems

    DOEpatents

    Longmire, J.L.; Thuot, M.E.; Warren, D.S.

    1982-08-23

    Prefires in a high-power, high-frequency, multi-stage pulse generator are detected by a system having an EMI shielded pulse timing transmitter associated with and tailored to each stage of the pulse generator. Each pulse timing transmitter upon detection of a pulse triggers a laser diode to send an optical signal through a high frequency fiber optic cable to a pulse timing receiver which converts the optical signal to an electrical pulse. The electrical pulses from all pulse timing receivers are fed through an OR circuit to start a time interval measuring device and each electrical pulse is used to stop an individual channel in the measuring device thereby recording the firing sequence of the multi-stage pulse generator.

  17. Prefire identification for pulse power systems

    DOEpatents

    Longmire, Jerry L.; Thuot, Michael E.; Warren, David S.

    1985-01-01

    Prefires in a high-power, high-frequency, multi-stage pulse generator are detected by a system having an EMI shielded pulse timing transmitter associated with and tailored to each stage of the pulse generator. Each pulse timing transmitter upon detection of a pulse triggers a laser diode to send an optical signal through a high frequency fiber optic cable to a pulse timing receiver which converts the optical signal to an electrical pulse. The electrical pulses from all pulse timing receivers are fed through an OR circuit to start a time interval measuring device and each electrical pulse is used to stop an individual channel in the measuring device thereby recording the firing sequence of the multi-stage pulse generator.

  18. HIGH POWER PULSED OSCILLATOR

    DOEpatents

    Singer, S.; Neher, L.K.

    1957-09-24

    A high powered, radio frequency pulse oscillator is described for generating trains of oscillations at the instant an input direct voltage is impressed, or immediately upon application of a light pulse. In one embodiment, the pulse oscillator comprises a photo-multiplier tube with the cathode connected to the first dynode by means of a resistor, and adjacent dynodes are connected to each other through adjustable resistors. The ohmage of the resistors progressively increases from a very low value for resistors adjacent the cathode to a high value adjacent the plate, the last dynode. Oscillation occurs with this circuit when a high negative voltage pulse is applied to the cathode and the photo cathode is bombarded. Another embodiment adds capacitors at the resistor connection points of the above circuit to increase the duration of the oscillator train.

  19. Plasma Switch for High-Power Active Pulse Compressor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirshfield, Jay L.

    2013-11-04

    Results are presented from experiments carried out at the Naval Research Laboratory X-band magnicon facility on a two-channel X-band active RF pulse compressor that employed plasma switches. Experimental evidence is shown to validate the basic goals of the project, which include: simultaneous firing of plasma switches in both channels of the RF circuit, operation of quasi-optical 3-dB hybrid directional coupler coherent superposition of RF compressed pulses from both channels, and operation of the X-band magnicon directly in the RF pulse compressor. For incident 1.2 ?s pulses in the range 0.63 ? 1.35 MW, compressed pulses of peak powers 5.7 ?more » 11.3 MW were obtained, corresponding to peak power gain ratios of 8.3 ? 9.3. Insufficient bakeout and conditioning of the high-power RF circuit prevented experiments from being conducted at higher RF input power levels.« less

  20. Compact, Portable Pulsed-Power

    DTIC Science & Technology

    2006-08-31

    adding this fast pulse to a slow, 30kV pulse which is below the threshold for significant corona emission. This scheme is presently being explored with...the smaller stressed electrode area. Further results from these systems were reported at the 2006 Power Modulator Conference in Washington, D.C...BLT and the medium-BLT is similar. The mini BLT electrodes are made of 3 mm thick molybdenum disks with a 3 mm central hole, capped on a hollow OFHC 1

  1. Design and development of compact pulsed power driver for electron beam experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deb, Pankaj; Sharma, S.K.; Adhikary, B.

    2014-07-01

    Pulsed electron beam generation requires high power pulses of fast rise, short duration pulse with flat top. With this objective we have designed a low cost compact pulsed power driver based on water dielectric transmission line. The paper describes the design aspects and construction of the pulse power driver and its experimental results. The pulsed power driver consist of a capacitor bank and its charging power supply, high voltage generator, high voltage switch and pulse compression system. (author)

  2. Pulsed power molten salt battery

    NASA Technical Reports Server (NTRS)

    Argade, Shyam D.

    1992-01-01

    It was concluded that carbon cathodes with chlorine work well. Lithium alloy chlorine at 450 C, 1 atm given high power capability, high energy density, DC + pulsing yields 600 pulses, no initial peak, and can go to red heat without burn-up. Electrochemical performance at the cell and cell stack level out under demanding test regime. Engineering and full prototype development for advancing this technology is warranted.

  3. Pulsed corona generation using a diode-based pulsed power generator

    NASA Astrophysics Data System (ADS)

    Pemen, A. J. M.; Grekhov, I. V.; van Heesch, E. J. M.; Yan, K.; Nair, S. A.; Korotkov, S. V.

    2003-10-01

    Pulsed plasma techniques serve a wide range of unconventional processes, such as gas and water processing, hydrogen production, and nanotechnology. Extending research on promising applications, such as pulsed corona processing, depends to a great extent on the availability of reliable, efficient and repetitive high-voltage pulsed power technology. Heavy-duty opening switches are the most critical components in high-voltage pulsed power systems with inductive energy storage. At the Ioffe Institute, an unconventional switching mechanism has been found, based on the fast recovery process in a diode. This article discusses the application of such a "drift-step-recovery-diode" for pulsed corona plasma generation. The principle of the diode-based nanosecond high-voltage generator will be discussed. The generator will be coupled to a corona reactor via a transmission-line transformer. The advantages of this concept, such as easy voltage transformation, load matching, switch protection and easy coupling with a dc bias voltage, will be discussed. The developed circuit is tested at both a resistive load and various corona reactors. Methods to optimize the energy transfer to a corona reactor have been evaluated. The impedance matching between the pulse generator and corona reactor can be significantly improved by using a dc bias voltage. At good matching, the corona energy increases and less energy reflects back to the generator. Matching can also be slightly improved by increasing the temperature in the corona reactor. More effective is to reduce the reactor pressure.

  4. Direct coupling of pulsed radio frequency and pulsed high power in novel pulsed power system for plasma immersion ion implantation.

    PubMed

    Gong, Chunzhi; Tian, Xiubo; Yang, Shiqin; Fu, Ricky K Y; Chu, Paul K

    2008-04-01

    A novel power supply system that directly couples pulsed high voltage (HV) pulses and pulsed 13.56 MHz radio frequency (rf) has been developed for plasma processes. In this system, the sample holder is connected to both the rf generator and HV modulator. The coupling circuit in the hybrid system is composed of individual matching units, low pass filters, and voltage clamping units. This ensures the safe operation of the rf system even when the HV is on. The PSPICE software is utilized to optimize the design of circuits. The system can be operated in two modes. The pulsed rf discharge may serve as either the seed plasma source for glow discharge or high-density plasma source for plasma immersion ion implantation (PIII). The pulsed high-voltage glow discharge is induced when a rf pulse with a short duration or a larger time interval between the rf and HV pulses is used. Conventional PIII can also be achieved. Experiments conducted on the new system confirm steady and safe operation.

  5. Extremely High Peak Power Obtained at 29 GHZ Microwave Pulse Generation

    NASA Astrophysics Data System (ADS)

    Rostov, V. V.; Gunin, A. V.; Romanchenko, I. V.; Pedos, M. S.; Rukin, S. N.; Sharypov, K. A.; Shunailov, S. A.; Ul'maskulov, M. R.; Yalandin, M. I.

    2017-12-01

    The paper presents research results on enhancing the peak power of microwave pulses with sub- and nanosecond length using a backward-wave oscillator (BWO) operating at 29 GHz frequency and possessing a reproducible phase structure. Experiments are conducted in two modes on a high-current electron accelerator with the required electron beam power. In the first (superradiation) mode, which utilizes the elongated slow-wave structure, the BWO peak power is 3 GW at 180 ns pulse duration (full width at halfmaximum, FWHM). In the second (quasi-stationary) mode, the BWO peak power reaches 600 MW at 2 ns pulse duration (FWHM). The phase spread from pulse to pulse can vary from units to several tens of percent in a nanosecond pulse mode. The experiments do not show any influence of microwave breakdown on the BWO power generation and radiation pulse duration.

  6. Agricultural and Food Processing Applications of Pulsed Power Technology

    NASA Astrophysics Data System (ADS)

    Takaki, Koichi; Ihara, Satoshi

    Recent progress of agricultural and food processing applications of pulsed power is described in this paper. Repetitively operated compact pulsed power generators with a moderate peak power have been developed for the agricultural and the food processing applications. These applications are mainly based on biological effects and can be categorized as decontamination of air and liquid, germination promotion, inhabitation of saprophytes growth, extraction of juice from fruits and vegetables, and fertilization of liquid medium, etc. Types of pulsed power that have biological effects are caused with gas discharges, water discharges, and electromagnetic fields. The discharges yield free radicals, UV radiation, intense electric field, and shock waves. Biologically based applications of pulsed power are performed by selecting the type that gives the target objects the adequate result from among these agents or byproducts. For instance, intense electric fields form pores on the cell membrane, which is called electroporation, or influence the nuclei.

  7. An explosively driven high-power microwave pulsed power system.

    PubMed

    Elsayed, M A; Neuber, A A; Dickens, J C; Walter, J W; Kristiansen, M; Altgilbers, L L

    2012-02-01

    The increased popularity of high power microwave systems and the various sources to drive them is the motivation behind the work to be presented. A stand-alone, self-contained explosively driven high power microwave pulsed power system has been designed, built, and tested at Texas Tech University's Center for Pulsed Power and Power Electronics. The system integrates four different sub-units that are composed of a battery driven prime power source utilizing capacitive energy storage, a dual stage helical flux compression generator as the main energy amplification device, an integrated power conditioning system with inductive energy storage including a fast opening electro-explosive switch, and a triode reflex geometry virtual cathode oscillator as the microwave radiating source. This system has displayed a measured electrical source power level of over 5 GW and peak radiated microwaves of about 200 MW. It is contained within a 15 cm diameter housing and measures 2 m in length, giving a housing volume of slightly less than 39 l. The system and its sub-components have been extensively studied, both as integrated and individual units, to further expand on components behavior and operation physics. This report will serve as a detailed design overview of each of the four subcomponents and provide detailed analysis of the overall system performance and benchmarks.

  8. An explosively driven high-power microwave pulsed power system

    NASA Astrophysics Data System (ADS)

    Elsayed, M. A.; Neuber, A. A.; Dickens, J. C.; Walter, J. W.; Kristiansen, M.; Altgilbers, L. L.

    2012-02-01

    The increased popularity of high power microwave systems and the various sources to drive them is the motivation behind the work to be presented. A stand-alone, self-contained explosively driven high power microwave pulsed power system has been designed, built, and tested at Texas Tech University's Center for Pulsed Power and Power Electronics. The system integrates four different sub-units that are composed of a battery driven prime power source utilizing capacitive energy storage, a dual stage helical flux compression generator as the main energy amplification device, an integrated power conditioning system with inductive energy storage including a fast opening electro-explosive switch, and a triode reflex geometry virtual cathode oscillator as the microwave radiating source. This system has displayed a measured electrical source power level of over 5 GW and peak radiated microwaves of about 200 MW. It is contained within a 15 cm diameter housing and measures 2 m in length, giving a housing volume of slightly less than 39 l. The system and its sub-components have been extensively studied, both as integrated and individual units, to further expand on components behavior and operation physics. This report will serve as a detailed design overview of each of the four subcomponents and provide detailed analysis of the overall system performance and benchmarks.

  9. Solid-state resistor for pulsed power machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoltzfus, Brian; Savage, Mark E.; Hutsel, Brian Thomas

    2016-12-06

    A flexible solid-state resistor comprises a string of ceramic resistors that can be used to charge the capacitors of a linear transformer driver (LTD) used in a pulsed power machine. The solid-state resistor is able to absorb the energy of a switch prefire, thereby limiting LTD cavity damage, yet has a sufficiently low RC charge time to allow the capacitor to be recharged without disrupting the operation of the pulsed power machine.

  10. [Research advances in Xp11.2 translocation renal cell carcinoma].

    PubMed

    Huang, Jian-Hua; Zhou, Fang-Jian

    2008-09-01

    Xp11.2 translocation renal cell carcinoma (RCC) is a newly identified category of RCC described in the 2004 WHO Classification of Kidney Tumors. Although the incidence is very rare, it accounts about one third of pediatric RCCs. It is different from other RCCs in clinical manifestations, histopathologic features, biological behaviour and prognosis. At present, Xp11.2 translocation RCC has seldom been reported. This review analyzed recent researches on Xp11.2 translocation RCC, described its classification and summarized the characteristics of epidemiology, clinical manifestations, histopathology, diagnosis, treatment and prognosis.

  11. Pulsed power systems for environmental and industrial applications

    NASA Astrophysics Data System (ADS)

    Neau, E. L.

    1994-10-01

    The development of high peak power simulators, laser drivers, free electron lasers, and Inertial Confinement Fusion drivers is being extended to high average power short-pulse machines with the capabilities of performing new roles in environmental cleanup and industrial manufacturing processes. We discuss a new class of short-pulse, high average power accelerator that achieves megavolt electron and ion beams with 10's of kiloamperes of current and average power levels in excess of 100 kW. Large treatment areas are possible with these systems because kilojoules of energy are available in each output pulse. These systems can use large area x-ray converters for applications requiring grater depth of penetration such as food pasteurization and waste treatment. The combined development of this class of accelerators and applications, and Sandia National Laboratories, is called Quantum Manufacturing.

  12. Pulse transmission transceiver architecture for low power communications

    DOEpatents

    Dress, Jr., William B.; Smith, Stephen F.

    2003-08-05

    Systems and methods for pulse-transmission low-power communication modes are disclosed. A method of pulse transmission communications includes: generating a modulated pulse signal waveform; transforming said modulated pulse signal waveform into at least one higher-order derivative waveform; and transmitting said at least one higher-order derivative waveform as an emitted pulse. The systems and methods significantly reduce lower-frequency emissions from pulse transmission spread-spectrum communication modes, which reduces potentially harmful interference to existing radio frequency services and users and also simultaneously permit transmission of multiple data bits by utilizing specific pulse shapes.

  13. High Power Particle Beams and Pulsed Power for Industrial Applications

    NASA Astrophysics Data System (ADS)

    Bluhm, Hansjoachim; An, Wladimir; Engelko, Wladimir; Giese, Harald; Frey, Wolfgang; Heinzel, Annette; Hoppé, Peter; Mueller, Georg; Schultheiss, Christoph; Singer, Josef; Strässner, Ralf; Strauß, Dirk; Weisenburger, Alfons; Zimmermann, Fritz

    2002-12-01

    Several industrial scale projects with economic and ecologic potential are presently emanating from research and development in the fields of high power particle beams and pulsed power in Europe. Material surface modifications with large area pulsed electron beams are used to protect high temperature gas turbine blades and steel structures in Pb/Bi cooled accelerator driven nuclear reactor systems against oxidation and corrosion respectively. Channel spark electron beams are applied to deposit bio-compatible or bio-active layers on medical implants. Cell membranes are perforated with strong pulsed electric fields to extract nutritive substances or raw materials from the cells and to kill bacteria for sterilization of liquids. Eletrodynamic fragmentation devices are developed to reutilize concrete aggregates for the production of high quality secondary concrete. All activities have a large potential to contribute to a more sustainable economy.

  14. Xp11.2 translocation renal carcinoma with placental metastasis: a case report.

    PubMed

    Bovio, Ian M; Allan, Robert W; Oliai, Bahram R; Hampton, Troy; Rush, Demaretta S

    2011-02-01

    Renal cell carcinomas with sporadic Xp11.2 translocations are uncommon malignancies in children and young adults associated with several different reciprocal translocations involving the TFE3 gene located on chromosome Xp11.2. Placental metastases are extremely rare, with only a handful of cases reported. This study reports the case of a 20-year-old woman with an Xp11.2 translocation renal carcinoma that metastasized to the placenta. This is the first reported case of a renal cell carcinoma metastatic to the placenta and highlights the aggressive behavior of Xp11 translocation renal cell carcinomas.

  15. Warm Dense Matter: Another Application for Pulsed Power Hydrodynamics

    DTIC Science & Technology

    2009-06-01

    Pulsed power hydrodynamic techniques, such as large convergence liner compression of a large volume, modest density, low temperature plasma to...controlled than are similar high explosively powered hydrodynamic experiments. While the precision and controllability of gas- gun experiments is...well established, pulsed power techniques using imploding liner offer access to convergent conditions, difficult to obtain with guns – and essential

  16. Low power pulsed MPD thruster system analysis and applications

    NASA Astrophysics Data System (ADS)

    Myers, Roger M.; Domonkos, Matthew; Gilland, James H.

    1993-06-01

    Pulsed MPD thruster systems were analyzed for application to solar-electric orbit transfer vehicles at power levels ranging from 10 to 40 kW. Potential system level benefits of pulsed propulsion technology include ease of power scaling without thruster performance changes, improved transportability from low power flight experiments to operational systems, and reduced ground qualification costs. Required pulsed propulsion system components include a pulsed applied-field MPD thruster, a pulse-forming network, a charge control unit, a cathode heater supply, and high speed valves. Mass estimates were obtained for each propulsion subsystem and spacecraft component. Results indicate that for payloads of 1000 and 2000 kg, pulsed MPD thrusters can reduce launch mass by between 1000 and 2500 kg relative to hydrogen arcjets, reducing launch vehicle class and launch cost. While the achievable mass savings depends on the trip time allowed for the mission, cases are shown in which the launch vehicle required for a mission is decreased from an Atlas IIAS to an Atlas I or Delta 7920.

  17. Beams 92: Proceedings. Volume 1: Invited papers, pulsed power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mosher, D.; Cooperstein, G.

    1993-12-31

    This report contains papers on the following topics: Ion beam papers; electron beam, bremsstrahlung, and diagnostics papers; radiating Z- pinch papers; microwave papers; electron laser papers; advanced accelerator papers; beam and pulsed power applications papers; pulsed power papers; and these papers have been indexed separately elsewhere.

  18. Chance, destiny, and the inner workings of ClpXP.

    PubMed

    Russell, Rick; Matouschek, Andreas

    2014-07-31

    AAA+ proteases are responsible for protein degradation in all branches of life. Using single-molecule and ensemble assays, Cordova et al. investigate how the bacterial protease ClpXP steps through a substrate's polypeptide chain and construct a quantitative kinetic model that recapitulates the interplay between stochastic and deterministic behaviors of ClpXP. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. TFE3-Fusion Variant Analysis Defines Specific Clinicopathologic Associations Among Xp11 Translocation Cancers

    PubMed Central

    Argani, Pedram; Zhong, Minghao; Reuter, Victor E.; Fallon, John T.; Epstein, Jonathan I.; Netto, George J.; Antonescu, Cristina R.

    2016-01-01

    Xp11 translocation cancers include Xp11 translocation renal cell carcinoma (RCC), Xp11 translocation perivascular epithelioid cell tumor (PEComa), and melanotic Xp11 translocation renal cancer. In Xp11 translocation cancers, oncogenic activation of TFE3 is driven by the fusion of TFE3 with a number of different gene partners, however, the impact of individual fusion variant on specific clinicopathologic features of Xp11 translocation cancers has not been well defined. In this study, we analyze 60 Xp11 translocation cancers by fluorescence in situ hybridization (FISH) using custom BAC probes to establish their TFE3 fusion gene partner. In 5 cases RNA sequencing (RNA-seq) was also used to further characterize the fusion transcripts. The 60 Xp11 translocation cancers included 47 Xp11 translocation RCC, 8 Xp11 translocation PEComas, and 5 melanotic Xp11 translocation renal cancers. A fusion partner was identified in 53/60 (88%) cases, including 18 SFPQ (PSF), 16 PRCC, 12 ASPSCR1 (ASPL), 6 NONO, and 1 DVL2. We provide the first morphologic description of the NONO-TFE3 RCC, which frequently demonstrates sub-nuclear vacuoles leading to distinctive suprabasal nuclear palisading. Similar sub-nuclear vacuolization was also characteristic of SFPQ-TFE3 RCC, creating overlapping features with clear cell papillary RCC. We also describe the first RCC with a DVL2-TFE3 gene fusion, in addition to an extrarenal pigmented PEComa with a NONO-TFE3 gene fusion. Furthermore, among neoplasms with the SFPQ-TFE3, NONO-TFE3, DVL2-TFE3 and ASPL-TFE3 gene fusions, the RCC are almost always PAX8-positive, cathepsin K-negative by immunohistochemistry, whereas the mesenchymal counterparts (Xp11 translocation PEComas, melanotic Xp11 translocation renal cancers, and alveolar soft part sarcoma) are PAX8-negative, cathepsin K-positive. These findings support the concept that despite an identical gene fusion, the RCCs are distinct from the corresponding mesenchymal neoplasms, perhaps due to the

  20. Influence of a falling edge on high power microwave pulse combination

    NASA Astrophysics Data System (ADS)

    Li, Jiawei; Huang, Wenhua; Zhu, Qi; Xiao, Renzhen; Shao, Hao

    2016-07-01

    This paper presents an explanation of the influence of a microwave falling edge on high-power microwave pulse combination. Through particle-in-cell simulations, we discover that the falling edge is the driving factor that limits the output power of the combined pulses. We demonstrate that the space charge field, which accumulates to become comparable to the E-field at the falling edge of the former pulse, will trap the electrons in the gas layer and decrease its energy to attain a high ionization rate. Hence, avalanche discharge, caused by trapped electrons, makes the plasma density to approach the critical density and cuts off the latter microwave pulse. An X-band combination experiment is conducted with different pulse intervals. This experiment confirms that the high density plasma induced by the falling edge can cut off the latter pulse, and that the time required for plasma recombination in the transmission channel is several microseconds. To ensure a high output power for combined pulses, the latter pulse should be moved ahead of the falling edge of the former one, and consequently, a beat wave with high peak power becomes the output by adding two pulses with normal amplitudes.

  1. A low power radiofrequency pulse for simultaneous multislice excitation and refocusing.

    PubMed

    Eichner, Cornelius; Wald, Lawrence L; Setsompop, Kawin

    2014-10-01

    Simultaneous multislice (SMS) acquisition enables increased temporal efficiency of MRI. Nonetheless, MultiBand (MB) radiofrequency (RF) pulses used for SMS can cause large energy deposition. Power independent of number of slices (PINS) pulses reduce RF power at cost of reduced bandwidth and increased off-resonance dependency. This work improves PINS design to further reduce energy deposition, off-resonance dependency and peak power. Modifying the shape of MB RF-pulses allows for mixing with PINS excitation, creating a new pulse type with reduced energy deposition and SMS excitation characteristics. Bloch Simulations were used to evaluate excitation and off-resonance behavior of this "MultiPINS" pulse. In this work, MultiPINS was used for whole-brain MB = 3 acquisition of high angular and spatial resolution diffusion MRI at 7 Tesla in 3 min. By using MultiPINS, energy transmission and peak power for SMS imaging can be significantly reduced compared with PINS and MB pulses. For MB = 3 acquisition in this work, MultiPINS reduces energy transmission by up to ∼50% compared with PINS pulses. The energy reduction was traded off to shorten the MultiPINS pulse, yielding higher signal at off-resonances for spin-echo acquisitions. MB and PINS pulses can be combined to enable low energy and peak power SMS acquisition. Copyright © 2014 Wiley Periodicals, Inc.

  2. Approaches to solar cell design for pulsed laser power receivers

    NASA Technical Reports Server (NTRS)

    Jain, Raj K.; Landis, Geoffrey A.

    1993-01-01

    Using a laser to beam power from Earth to a photovoltaic receiver in space could be a technology with applications to many space missions. Extremely high average-power lasers would be required in a wavelength range of 700-1000 nm. However, high-power lasers inherently operate in a pulsed format. Existing solar cells are not well designed to respond to pulsed incident power. To better understand cell response to pulsed illumination at high intensity, the PC-1D finite-element computer model was used to analyze the response of solar cells to continuous and pulsed laser illumination. Over 50 percent efficiency was calculated for both InP and GaAs cells under steady-state illumination near the optimum wavelength. The time-dependent response of a high-efficiency GaAs concentrator cell to a laser pulse was modeled, and the effect of laser intensity, wavelength, and bias point was studied. Three main effects decrease the efficiency of a solar cell under pulsed laser illumination: series resistance, L-C 'ringing' with the output circuit, and current limiting due to the output inductance. The problems can be solved either by changing the pulse shape or designing a solar cell to accept the pulsed input. Cell design possibilities discussed are a high-efficiency, light-trapping silicon cell, and a monolithic, low-inductance GaAs cell.

  3. Low power pulsed MPD thruster system analysis and applications

    NASA Astrophysics Data System (ADS)

    Myers, Roger M.; Domonkos, Matthew; Gilland, James H.

    1993-09-01

    Pulsed magnetoplasmadynamic (MPD) thruster systems were analyzed for application to solar-electric orbit transfer vehicles at power levels ranging from 10 to 40 kW. Potential system level benefits of pulsed propulsion technology include ease of power scaling without thruster performance changes, improved transportability from low power flight experiments to operational systems, and reduced ground qualification costs. Required pulsed propulsion system components include a pulsed applied-field MPD thruster, a pulse-forming network, a charge control unit, a cathode heater supply, and high speed valves. Mass estimates were obtained for each propulsion subsystem and spacecraft component using off-the-shelf technology whenever possible. Results indicate that for payloads of 1000 and 2000 kg pulsed MPD thrusters can reduce launch mass by between 1000 and 2500 kg over those achievable with hydrogen arcjets, which can be used to reduce launch vehicle class and the associated launch cost. While the achievable mass savings depends on the trip time allowed for the mission, cases are shown in which the launch vehicle required for a mission is decreased from an Atlas IIAS to an Atlas I or Delta 7920.

  4. Low power pulsed MPD thruster system analysis and applications

    NASA Technical Reports Server (NTRS)

    Myers, Roger M.; Domonkos, Matthew; Gilland, James H.

    1993-01-01

    Pulsed magnetoplasmadynamic (MPD) thruster systems were analyzed for application to solar-electric orbit transfer vehicles at power levels ranging from 10 to 40 kW. Potential system level benefits of pulsed propulsion technology include ease of power scaling without thruster performance changes, improved transportability from low power flight experiments to operational systems, and reduced ground qualification costs. Required pulsed propulsion system components include a pulsed applied-field MPD thruster, a pulse-forming network, a charge control unit, a cathode heater supply, and high speed valves. Mass estimates were obtained for each propulsion subsystem and spacecraft component using off-the-shelf technology whenever possible. Results indicate that for payloads of 1000 and 2000 kg pulsed MPD thrusters can reduce launch mass by between 1000 and 2500 kg over those achievable with hydrogen arcjets, which can be used to reduce launch vehicle class and the associated launch cost. While the achievable mass savings depends on the trip time allowed for the mission, cases are shown in which the launch vehicle required for a mission is decreased from an Atlas IIAS to an Atlas I or Delta 7920.

  5. Airy pulse shaping using time-dependent power-law potentials

    NASA Astrophysics Data System (ADS)

    Han, Tianwen; Chen, Hao; Qin, Chengzhi; Li, Wenwan; Wang, Bing; Lu, Peixiang

    2018-06-01

    We investigate the temporal and spectral evolutions of finite-energy Airy pulses in the presence of power-law optical potentials. The potentials are generated by the time-dependent pumped light, which propagates together with the Airy pulses in a highly nonlinear optical fiber. We show that the intrinsic acceleration of Airy pulses can be modified by an external force that stems from a linear potential, and hence unidirectional frequency shift can be realized. When a triangle potential is employed, the pulse will exhibit self-splitting both in temporal and spectral domains. Additionally, as a parabolic potential is utilized, both the temporal waveform and frequency spectrum of the Airy pulse will exchange alternately between the Airy and Gaussian profiles. By using higher-order power-law potentials, we also realize both revival and antirevival effects for the Airy pulses. The study may find wide applications in pulse reshaping and spectral-temporal imaging for both optical communication and signal processing.

  6. Xp11.2 translocation renal cell carcinoma with PSF-TFE3 rearrangement.

    PubMed

    Zhong, Minghao; Weisman, Paul; Zhu, Bing; Brassesco, Maria; Yang, Youfeng; Linehan, W Marston; Merino, Maria J; Zhang, David; Rohan, Stephen; Cai, Dongming; Yang, Ximing

    2013-06-01

    Xp11.2 translocation renal cell carcinoma (Xp11.2 RCC) is a subtype of RCC characterized by translocations involving a breakpoint at the TFE3 gene (Xp11.2). Moderate to strong nuclear TFE3 immunoreactivity has been recognized as a specific diagnostic marker for this type of tumor. However, exclusive cytoplasmic localization of a TFE3 fusion protein was reported in UOK 145 cells, a cell line derived from an Xp11.2 RCC harboring the PSF-TFE3 translocation. If reproducible using immunohistochemistry (IHC), this finding would have important implications for pathologists in the diagnosis of Xp11.2 RCC, calling into question the specificity of nuclear immunoreactivity for TFE3 in these tumors. The purpose of this study was to determine whether the above-noted cytoplasmic localization of the TFE3 fusion protein could be reproduced using IHC. UOK 145 cells and fresh frozen tissue from 2 clinical cases of Xp11.2 RCC found to harbor the PSF-TFE3 gene rearrangement (by cytogenetic testing) were collected. All samples were subjected to histopathologic evaluation by board-certified pathologists, TFE3 IHC, reverse transcription polymerase chain reaction, and Sanger sequencing analysis. A strong nuclear TFE3 immunoreactivity was demonstrated in all samples including the UOK 145 cell line. No cytoplasmic immunoreactivity was seen. Reverse transcription polymerase chain reaction and Sanger sequencing confirmed the previously reported PSF-TFE3 gene fusion between exon 9 of PSF and exon 6 of TFE3 in the UOK 145 cell line and in one of 2 clinical cases of Xp11.2 RCC. A novel PSF-TFE3 gene fusion between exon 9 of PSF and exon 5 of TFE3 was detected in the second clinical case of Xp11.2 RCC.

  7. Multirail electromagnetic launcher powered from a pulsed magnetohydrodynamic generator

    NASA Astrophysics Data System (ADS)

    Afonin, A. G.; Butov, V. G.; Panchenko, V. P.; Sinyaev, S. V.; Solonenko, V. A.; Shvetsov, G. A.; Yakushev, A. A.

    2015-09-01

    The operation of an electromagnetic multirail launcher of solids powered from a pulsed magnetohydrodynamic (MHD) generator is studied. The plasma flow in the channel of the pulsed MHD generator and the possibility of launching solids in a rapid-fire mode of launcher operation are considered. It is shown that this mode of launcher operation can be implemented by matching the plasma flow dynamics in the channel of the pulsed MHD generator and the launching conditions. It is also shown that powerful pulsed MHD generators can be used as a source of electrical energy for rapid-fire electromagnetic rail launchers operating in a burst mode.

  8. Clinicopathological features of Xp11.2 translocation renal cell carcinoma.

    PubMed

    Lim, Bumjin; You, Dalsan; Jeong, In Gab; Kwon, Taekmin; Hong, Sungwoo; Song, Cheryn; Cho, Yong Mee; Hong, Bumsik; Hong, Jun Hyuk; Ahn, Hanjong; Kim, Choung Soo

    2015-03-01

    Xp11.2 translocation renal cell carcinoma (RCC) is characterized by various translocations of the TFE3 transcription factor gene. These rare cancers occur predominantly in children and young adults. Here, we review the clinicopathological features of Xp11.2 translocation RCC. We identified 21 patients with Xp11.2 translocation RCC. We retrospectively analyzed patient characteristics, clinical manifestations, and specific pathological features to assess definitive diagnosis, surgical and systemic treatments, and clinical outcomes. The mean age at diagnosis was 43.4±20.0 years (range, 8-80 years; 8 males and 13 females). Eleven patients were incidentally diagnosed, nine patients presented with local symptoms, and one patient presented with systemic symptoms. The mean tumor size was 6.2±3.8 cm (range, 1.9-14 cm). At the time of diagnosis, 11, 1, and 5 patients showed stage I, II, and III, respectively. Four patients showed distant metastasis. At analysis, 15 patients were disease-free after a median follow-up period of 30.0 months. Four patients received target therapy but not effectively. Xp11 translocation RCC tends to develop in young patients with lymph node metastasis. Targeted therapy did not effectively treat our patients. Surgery is the only effective therapy for Xp11 translocation RCC, and further studies are needed to assess systemic therapy and long-term prognosis.

  9. Clinicopathological features of Xp11.2 translocation renal cell carcinoma

    PubMed Central

    Lim, Bumjin; You, Dalsan; Jeong, In Gab; Kwon, Taekmin; Hong, Sungwoo; Song, Cheryn; Cho, Yong Mee; Hong, Bumsik; Hong, Jun Hyuk; Ahn, Hanjong

    2015-01-01

    Purpose Xp11.2 translocation renal cell carcinoma (RCC) is characterized by various translocations of the TFE3 transcription factor gene. These rare cancers occur predominantly in children and young adults. Here, we review the clinicopathological features of Xp11.2 translocation RCC. Materials and Methods We identified 21 patients with Xp11.2 translocation RCC. We retrospectively analyzed patient characteristics, clinical manifestations, and specific pathological features to assess definitive diagnosis, surgical and systemic treatments, and clinical outcomes. Results The mean age at diagnosis was 43.4±20.0 years (range, 8-80 years; 8 males and 13 females). Eleven patients were incidentally diagnosed, nine patients presented with local symptoms, and one patient presented with systemic symptoms. The mean tumor size was 6.2±3.8 cm (range, 1.9-14 cm). At the time of diagnosis, 11, 1, and 5 patients showed stage I, II, and III, respectively. Four patients showed distant metastasis. At analysis, 15 patients were disease-free after a median follow-up period of 30.0 months. Four patients received target therapy but not effectively. Conclusions Xp11 translocation RCC tends to develop in young patients with lymph node metastasis. Targeted therapy did not effectively treat our patients. Surgery is the only effective therapy for Xp11 translocation RCC, and further studies are needed to assess systemic therapy and long-term prognosis. PMID:25763125

  10. Transformative Pulsed Power Science and Technology

    DTIC Science & Technology

    2014-12-16

    Lin, D. Singleton, J. Sanders, A. Kuthi and M.A. Gundersen, “Experimental study of pulsed corona discharge in air at high pressures”, 65th Annual...Kastner, E. Gutmark, and M. A. Gundersen. “Surface Streamer Discharge for Plasma Flow Control Using Nanosecond Pulsed Power.” Plasma Sciences, IEEE... discharge in atmospheric pressure fuel/air mixtures”, J. Phys. D: Appl. Phys. 45 495401 (2012). 28. S. J. Pendleton, S. Bowman, C. Carter, M. A. Gundersen

  11. Influence of a falling edge on high power microwave pulse combination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jiawei; Huang, Wenhua; Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi'an 710024

    This paper presents an explanation of the influence of a microwave falling edge on high-power microwave pulse combination. Through particle-in-cell simulations, we discover that the falling edge is the driving factor that limits the output power of the combined pulses. We demonstrate that the space charge field, which accumulates to become comparable to the E-field at the falling edge of the former pulse, will trap the electrons in the gas layer and decrease its energy to attain a high ionization rate. Hence, avalanche discharge, caused by trapped electrons, makes the plasma density to approach the critical density and cuts offmore » the latter microwave pulse. An X-band combination experiment is conducted with different pulse intervals. This experiment confirms that the high density plasma induced by the falling edge can cut off the latter pulse, and that the time required for plasma recombination in the transmission channel is several microseconds. To ensure a high output power for combined pulses, the latter pulse should be moved ahead of the falling edge of the former one, and consequently, a beat wave with high peak power becomes the output by adding two pulses with normal amplitudes.« less

  12. Pulsed power accelerator for material physics experiments

    DOE PAGES

    Reisman, D.  B.; Stoltzfus, B.  S.; Stygar, W.  A.; ...

    2015-09-01

    We have developed the design of Thor: a pulsed power accelerator that delivers a precisely shaped current pulse with a peak value as high as 7 MA to a strip-line load. The peak magnetic pressure achieved within a 1-cm-wide load is as high as 100 GPa. Thor is powered by as many as 288 decoupled and transit-time isolated bricks. Each brick consists of a single switch and two capacitors connected electrically in series. The bricks can be individually triggered to achieve a high degree of current pulse tailoring. Because the accelerator is impedance matched throughout, capacitor energy is delivered tomore » the strip-line load with an efficiency as high as 50%. We used an iterative finite element method (FEM), circuit, and magnetohydrodynamic simulations to develop an optimized accelerator design. When powered by 96 bricks, Thor delivers as much as 4.1 MA to a load, and achieves peak magnetic pressures as high as 65 GPa. When powered by 288 bricks, Thor delivers as much as 6.9 MA to a load, and achieves magnetic pressures as high as 170 GPa. We have developed an algebraic calculational procedure that uses the single brick basis function to determine the brick-triggering sequence necessary to generate a highly tailored current pulse time history for shockless loading of samples. Thor will drive a wide variety of magnetically driven shockless ramp compression, shockless flyer plate, shock-ramp, equation of state, material strength, phase transition, and other advanced material physics experiments.« less

  13. The XP spaceplane: A near term multi-purpose suborbital RLV

    NASA Astrophysics Data System (ADS)

    Lauer, Charles J.

    2007-06-01

    This paper will describe the history, technology and design features of the XP spaceplane being developed by Rocketplane Ltd. in Oklahoma. The XP is a four seat fighter-sized spaceplane that uses turbojets for takeoff and landing and a liquid oxygen/kerosene rocket engine for main propulsion during its ascent to a 100 km apogee suborbital space flight. The XP is intended to serve a variety of markets including suborbital tourist flights, intermediate duration microgravity research, remote sensing, astronomy, and microsatellite launch missions. Changes in vehicle configuration and flight profile for serving each of these markets will be described. The prototype XP will have its rollout ceremony at the end of 2007 and will begin test flights in early 2008. Commercial space flight operations are expected to begin in fall 2008 with tourist flights and microgravity research flights being the early customer base. The spaceplane's flight systems, safety systems, and operating procedures will be reviewed. In addition, key elements of the Rocketplane business and financial model will be discussed.

  14. [A case of xp11.2 translocation renal cell carcinoma].

    PubMed

    Horie, Kengo; Kikuchi, Mina; Miwa, Kosei; Minamidate, Yuzuru; Yokoi, Shigeaki; Nakano, Masahiro; Deguchi, Takashi; Ehara, Hidetoshi; Asano, Nami; Hirose, Yoshinobu

    2011-03-01

    Xp11.2/TFE3 translocation renal cell carcinoma (RCC), a recently classified distinct subtype, is a rare tumor that usually affects children and adolescents. The morphology and biological behavior are not widely recognized, Xp11.2 translocation RCC is suggestive of early metastases despite the small tumor size. The definitive diagnosis requires the evidence of several different reciprocal translocations involving the TFE3 gene located on chromosome Xp11.2. Here, we present a case of Xp11.2 translocation RCC in an 18-yearold male. He was referred to our hospital because of a right renal tumor with macroscopic hematuria and right flank colic. The radiographic evaluation including magnetic resonance imaging (MRI) suggested it to be a typical papillary renal cell carcinoma or benign renal tumor. He underwent laparoscopic nephrectomy against the repeat symptom in spite of small tumor (3.5 cm in diameter). The immunohistochemical study revealed nuclear staining for TFE3 protein in the cancer cells. The urologic and radiologic outcomes were satisfactory after more than 1 year of follow-up.

  15. Nonlinear pulse compression stage delivering 43-W few-cycle pulses with GW peak-power at 2-μm wavelength

    NASA Astrophysics Data System (ADS)

    Gebhardt, Martin; Gaida, Christian; Heuermann, T.; Stutzki, F.; Jauregui, C.; Antonio-Lopez, J.; Schüuzgen, A.; Amezcua-Correa, R.; Tünnermann, A.; Limpert, J.

    2018-02-01

    In this contribution we demonstrate the nonlinear pulse compression of an ultrafast thulium-doped fiber laser down to 14 fs FWHM duration (sub-3 optical cycles) at a record average power of 43 W and 34.5 μJ pulse energy. To the best of our knowledge, we present the highest average power few-cycle laser source at 2 μm wavelength. This performance level in combination with GW-class peak power makes our laser source extremely interesting for driving high-harmonic generation or for generating mid-infrared frequency combs via intra-pulse frequency down-conversion at an unprecedented average power. The experiments were enabled by an ultrafast thulium-doped fiber laser delivering 110 fs pulses at high repetition rates, and an argon gas-filled antiresonant hollow-core fiber (ARHCF) with excellent transmission and weak anomalous dispersion, leading to the self-compression of the pulses. We have shown that ARHCFs are well-suited for nonlinear pulse compression around 2 μm wavelength and that this concept features excellent power handling capabilities. Based on this result, we discuss the next steps for energy and average power scaling including upscaling the fiber dimensions in order to fully exploit the capabilities of our laser system, which can deliver several GW of peak power. This way, a 100 W-class laser source with mJ-level few-cycle pulses at 2 μm wavelength is feasible in the near future.

  16. Xp11 translocation renal cell carcinoma in adults: a clinicopathological and comparative genomic hybridization study.

    PubMed

    Zou, Hong; Kang, Xueling; Pang, Li-Juan; Hu, Wenhao; Zhao, Jin; Qi, Yan; Hu, Jianming; Liu, Chunxia; Li, Hongan; Liang, Weihua; Yuan, Xianglin; Li, Feng

    2014-01-01

    To study the clinicopathological and genomic characteristics of Xp11.2 translocation renal cell carcinoma (Xp11.2 RCC) in adults, we analyzed 9 Xp11.2 RCCs, confirmed by transcription factor E3 (TFE3) immunohistochemistry, in patients aged ≥20 years. TFE3 expression was also determined in 12 cases of alveolar soft part sarcoma (ASPS) served as a positive control. Comparative genomic hybridization (CGH) was used to investigate genomic imbalances in all Xp11.2 RCC cases. Most of our Xp11.2 RCC patients (5/9) presented with TNM stages 3-4, and 6 patients died 10 months to 7 years after their operation. Histologically, Xp11.2 RCC was composed of a mixed papillary nested/alveolar growth pattern (8/9). Immunostaining showed that all Xp11.2 RCC and ASPS cases had strong TFE3 expression and high positive ratios for p53 and vimentin. However, there were significant differences in the expression of AMACR (p<0.001), AE1/AE3 (p=0.002), and CD10 (p=0.024) between the 2 diseases. CGH profiles showed chromosomal imbalances in all 9 Xp11.2 RCC cases; gains were observed in chromosomes Xp11 (6/9), 7q20-25, 12q25-31 (5/9), 7p16-24 (4/9), 8p12-13, 8q20-21, 16q20-22, 17q25-26, 20q22-23 (4/9), and losses occurred frequently on chromosomes 3p12-16, 9q31-32, 14q22-24 (4/9). Our Conclusions show Xp11.2 RCC that occur in adults may be aggressive cancers, the expressions of AMACR, CD10, AE1/AE3 are helpful in the differential diagnosis between Xp11.2 RCC and ASPS, and CGH assay is a useful complementary method for confirming the diagnosis of Xp11.2 RCC.

  17. Xp11 translocation renal cell carcinoma in adults: a clinicopathological and comparative genomic hybridization study

    PubMed Central

    Zou, Hong; Kang, Xueling; Pang, Li-Juan; Hu, Wenhao; Zhao, Jin; Qi, Yan; Hu, Jianming; Liu, Chunxia; Li, Hongan; Liang, Weihua; Yuan, Xianglin; Li, Feng

    2014-01-01

    To study the clinicopathological and genomic characteristics of Xp11.2 translocation renal cell carcinoma (Xp11.2 RCC) in adults, we analyzed 9 Xp11.2 RCCs, confirmed by transcription factor E3 (TFE3) immunohistochemistry, in patients aged ≥20 years. TFE3 expression was also determined in 12 cases of alveolar soft part sarcoma (ASPS) served as a positive control. Comparative genomic hybridization (CGH) was used to investigate genomic imbalances in all Xp11.2 RCC cases. Most of our Xp11.2 RCC patients (5/9) presented with TNM stages 3-4, and 6 patients died 10 months to 7 years after their operation. Histologically, Xp11.2 RCC was composed of a mixed papillary nested/alveolar growth pattern (8/9). Immunostaining showed that all Xp11.2 RCC and ASPS cases had strong TFE3 expression and high positive ratios for p53 and vimentin. However, there were significant differences in the expression of AMACR (p<0.001), AE1/AE3 (p=0.002), and CD10 (p=0.024) between the 2 diseases. CGH profiles showed chromosomal imbalances in all 9 Xp11.2 RCC cases; gains were observed in chromosomes Xp11 (6/9), 7q20-25, 12q25-31 (5/9), 7p16-24 (4/9), 8p12-13, 8q20-21, 16q20-22, 17q25-26, 20q22-23 (4/9), and losses occurred frequently on chromosomes 3p12-16, 9q31-32, 14q22-24 (4/9). Our Conclusions show Xp11.2 RCC that occur in adults may be aggressive cancers, the expressions of AMACR, CD10, AE1/AE3 are helpful in the differential diagnosis between Xp11.2 RCC and ASPS, and CGH assay is a useful complementary method for confirming the diagnosis of Xp11.2 RCC. PMID:24427344

  18. Pulse Detonation Rocket Magnetohydrodynamic Power Experiment

    NASA Technical Reports Server (NTRS)

    Litchford, R. J.; Jones, J. E.; Dobson, C. C.; Cole, J. W.; Thompson, B. R.; Plemmons, D. H.; Turner, M. W.

    2003-01-01

    The production of onboard electrical power by pulse detonation engines is problematic in that they generate no shaft power; however, pulse detonation driven magnetohydrodynamic (MHD) power generation represents one intriguing possibility for attaining self-sustained engine operation and generating large quantities of burst power for onboard electrical systems. To examine this possibility further, a simple heat-sink apparatus was developed for experimentally investigating pulse detonation driven MHD generator concepts. The hydrogen oxygen fired driver was a 90 cm long stainless steel tube having a 4.5 cm square internal cross section and a short Schelkin spiral near the head end to promote rapid formation of a detonation wave. The tube was intermittently filled to atmospheric pressure and seeded with a CsOH/methanol prior to ignition by electrical spark. The driver exhausted through an aluminum nozzle having an area contraction ratio of A*/A(sub zeta) = 1/10 and an area expansion ratio of A(sub zeta)/A* = 3.2 (as limited by available magnet bore size). The nozzle exhausted through a 24-electrode segmented Faraday channel (30.5 cm active length), which was inserted into a 0.6 T permanent magnet assembly. Initial experiments verified proper drive operation with and without the nozzle attachment, and head end pressure and time resolved thrust measurements were acquired. The exhaust jet from the nozzle was interrogated using a polychromatic microwave interferometer yielding an electron number density on the order of 10(exp 12)/cm at the generator entrance. In this case, MHD power generation experiments suffered from severe near-electrode voltage drops and low MHD interaction; i.e., low flow velocity, due to an inherent physical constraint on expansion with the available magnet. Increased scaling, improved seeding techniques, higher magnetic fields, and higher expansion ratios are expected to greatly improve performance.

  19. Agricultural and Food Processing Applications of Pulsed Power and Plasma Technologies

    NASA Astrophysics Data System (ADS)

    Takaki, Koichi

    Agricultural and food processing applications of pulsed power and plasma technologies are described in this paper. Repetitively operated compact pulsed power generators with a moderate peak power are developed for the agricultural and the food processing applications. These applications are mainly based on biological effects and can be categorized as germination control of plants such as Basidiomycota and arabidopsis inactivation of bacteria in soil and liquid medium of hydroponics; extraction of juice from fruits and vegetables; decontamination of air and liquid, etc. Types of pulsed power that have biological effects are caused with gas discharges, water discharges, and electromagnetic fields. The discharges yield free radicals, UV radiation, intense electric field, and shock waves. Biologically based applications of pulsed power and plasma are performed by selecting the type that gives the target objects the adequate result from among these agents or byproducts. For instance, intense electric fields form pores on the cell membrane, which is called electroporation, or influence the nuclei. This paper mainly describes the application of the pulsed power for the germination control of Basidiomycota i.e. mushroom, inactivation of fungi in the soil and the liquid medium in hydroponics, and extraction of polyphenol from skins of grape.

  20. A family with X-linked optic atrophy linked to the OPA2 locus Xp11.4-Xp11.2.

    PubMed

    Katz, Bradley J; Zhao, Yu; Warner, Judith E A; Tong, Zongzhong; Yang, Zhenglin; Zhang, Kang

    2006-10-15

    Autosomal dominant optic atrophy (ADOA) is the most common inherited optic atrophy. Clinical features of ADOA include a slowly progressive bilateral loss of visual acuity, constriction of peripheral visual fields, central scotomas, and color vision abnormalities. Although ADOA is the most commonly inherited optic atrophy, autosomal recessive, X-linked, mitochondrial, and sporadic forms have also been reported. Four families with X-linked optic atrophy (XLOA) were previously described. One family was subsequently linked to Xp11.4-Xp11.2 (OPA2). This investigation studied one multi-generation family with an apparently X-linked form of optic atrophy and compared their clinical characteristics with those of the previously described families, and determined whether this family was linked to the same genetic locus. Fifteen individuals in a three-generation Idaho family underwent complete eye examination, color vision testing, automated perimetry, and fundus photography. Polymorphic markers were used to genotype each individual and to determine linkage. Visual acuities ranged from 20/30 to 20/100. All affected subjects had significant optic nerve pallor. Obligate female carriers were clinically unaffected. Preliminary linkage analysis (LOD score = 1.8) revealed that the disease gene localized to the OPA2 locus on Xp11.4-Xp11.2. Four forms of inherited optic neuropathy, ADOA, autosomal recessive optic atrophy (Costeff Syndrome), Leber hereditary optic neuropathy, and Charcot-Marie-Tooth disease with optic atrophy, are associated with mitochondrial dysfunction. Future identification of the XLOA gene will reveal whether this form of optic atrophy is also associated with a mitochondrial defect. Identification of the XLOA gene will advance our understanding of the inherited optic neuropathies and perhaps suggest treatments for these diseases. An improved understanding of inherited optic neuropathies may in turn advance our understanding of acquired optic nerve diseases, such

  1. Power supply and pulsing strategies for the future linear colliders

    NASA Astrophysics Data System (ADS)

    Brogna, A. S.; Göttlicher, P.; Weber, M.

    2012-02-01

    The concept of the power delivery systems of the future linear colliders exploits the pulsed bunch structure of the beam in order to minimize the average current in the cables and the electronics and thus to reduce the material budget and heat dissipation. Although modern integrated circuit technologies are already available to design a low-power system, the concepts on how to pulse the front-end electronics and further reduce the power are not yet well understood. We propose a possible implementation of a power pulsing system based on a DC/DC converter and we choose the Analog Hadron Calorimeter as a specific example. The model features large switching currents of electronic modules in short time intervals to stimulate the inductive components along the cables and interconnections.

  2. Long-pulse power-supply system for EAST neutral-beam injectors

    NASA Astrophysics Data System (ADS)

    Liu, Zhimin; Jiang, Caichao; Pan, Junjun; Liu, Sheng; Xu, Yongjian; Chen, Shiyong; Hu, Chundong; NBI Team

    2017-05-01

    The long-pulse power-supply system equipped for the 4 MW beam-power ion source is comprised of three units at ASIPP (Institute of Plasma Physics, Chinese Academy of Sciences): one for the neutral-beam test stand and two for the EAST neutral-beam injectors (NBI-1 and NBI-2, respectively). Each power supply system consists of two low voltage and high current DC power supplies for plasma generation of the ion source, and two high voltage and high current DC power supplies for the accelerator grid system. The operation range of the NB power supply is about 80 percent of the design value, which is the safe and stable operation range. At the neutral-beam test stand, a hydrogen ion beam with a beam pulse of 150 s, beam power of 1.5 MW and beam energy of 50 keV was achieved during the long-pulse testing experiments. The result shows that the power-supply system meets the requirements of the EAST-NBIs fully and lays a basis for achieving plasma heating.

  3. PCF based high power narrow line width pulsed fiber laser

    NASA Astrophysics Data System (ADS)

    Chen, H.; Yan, P.; Xiao, Q.; Wang, Y.; Gong, M.

    2012-09-01

    Based on semiconductor diode seeded multi-stage cascaded fiber amplifiers, we have obtained 88-W average power of a 1063-nm laser with high repetition rate of up to 1.5 MHz and a constant 2-ns pulse duration. No stimulated Brillouin scattering pulse or optical damage occurred although the maximum pulse peak power has exceeded 112 kW. The output laser exhibits excellent beam quality (M2x = 1.24 and M2y = 1.18), associated with a spectral line width as narrow as 0.065 nm (FWHM). Additionally, we demonstrate high polarization extinction ratio of 18.4 dB and good pulse stabilities superior to 1.6 % (RMS).

  4. Stability and Control Characteristics of a 1/10-Scale Model of the McDonnell XP-85 Airplane While Attached to the Trapeze

    NASA Technical Reports Server (NTRS)

    Johnson, Joseph L.

    1947-01-01

    At the request of the Air Materiel Command, Army Air Forces, an investigation of the low-speed, power-off, stability and control characteristics of the McDonnell XP-85 airplane has been conducted in the Langley free-flight tunnel. The results of the portion of the investigation consisting of tests of a 1/10-scale model to study the stability of the XP-85 when attached to the trapeze and during retraction into the B-36 bomb bay are presented herein. In the power-off condition the stability was satisfactory with all oscillations well damped and the nose-restraining collar could be placed in position without difficulty. In a simulated power-on condition the model had a constant-amplitude rolling and sidewise motion and when the collar was layered, a violent motion resulted if the collar struck the model but failed to hold it in the proper manner. Folding of the wings and retraction into the bomb bay offered no problem once the airplane was properly held by the collar. It is recommended that the power be cut immediately after hooking on and that a restricting mechanism be incorporated in the center of the trapeze to eliminate the sidewise motion. It also appears desirable to have the retracting procedure controlled by the XP-85 pilot or an observer in the mother ship to insure that the parasite is in proper position after hooking up before bringing the collar down.

  5. Pulsed characterization of a UV LED for pulsed power applications on a silicon carbide photoconductive semiconductor switch

    NASA Astrophysics Data System (ADS)

    Wilson, Nicholas; Mauch, Daniel; Meyers, Vincent; Feathers, Shannon; Dickens, James; Neuber, Andreas

    2017-08-01

    The electrical and optical characteristics of a high-power UV light emitting diode (LED) (365 nm wavelength) were evaluated under pulsed operating conditions at current amplitudes several orders of magnitude beyond the LED's manufacturer specifications. Geared towards triggering of photoconductive semiconductor switches (PCSSs) for pulsed power applications, measurements were made over varying pulse widths (25 ns-100 μs), current (0 A-250 A), and repetition rates (single shot-5 MHz). The LED forward voltage was observed to increase linearly with increasing current (˜3.5 V-53 V) and decrease with increasing pulse widths. The peak optical power observed was >30 W, and a maximum system efficiency of 23% was achieved. The evaluated LED and auxiliary hardware were successfully used as the optical trigger source for a 4H-SiC PCSS. The lowest measured on-resistance of SiC was approximately 67 kΩ.

  6. Pulsed characterization of a UV LED for pulsed power applications on a silicon carbide photoconductive semiconductor switch.

    PubMed

    Wilson, Nicholas; Mauch, Daniel; Meyers, Vincent; Feathers, Shannon; Dickens, James; Neuber, Andreas

    2017-08-01

    The electrical and optical characteristics of a high-power UV light emitting diode (LED) (365 nm wavelength) were evaluated under pulsed operating conditions at current amplitudes several orders of magnitude beyond the LED's manufacturer specifications. Geared towards triggering of photoconductive semiconductor switches (PCSSs) for pulsed power applications, measurements were made over varying pulse widths (25 ns-100 μs), current (0 A-250 A), and repetition rates (single shot-5 MHz). The LED forward voltage was observed to increase linearly with increasing current (∼3.5 V-53 V) and decrease with increasing pulse widths. The peak optical power observed was >30 W, and a maximum system efficiency of 23% was achieved. The evaluated LED and auxiliary hardware were successfully used as the optical trigger source for a 4H-SiC PCSS. The lowest measured on-resistance of SiC was approximately 67 kΩ.

  7. Electromagnetic-Pulse Handbook for Electric Power Systems

    DTIC Science & Technology

    1975-02-04

    penetratlor.s such as communications cables, antenna leads, etc.). (6) Avoid connecting the power neutral and external cable shields to the same point on the...prepared primarily for the power, communications , and systems engineer who must be concerned with the offects of the nuclear electromagnetic pulse on...INTRODUCTION Until a few years ago, the nuclear EMP community gave little attention to commer- cial power systems other than to recommend surge arrestors

  8. Self-channeling of high-power laser pulses through strong atmospheric turbulence

    NASA Astrophysics Data System (ADS)

    Peñano, J.; Palastro, J. P.; Hafizi, B.; Helle, M. H.; DiComo, G. P.

    2017-07-01

    We present an unusual example of truly long-range propagation of high-power laser pulses through strong atmospheric turbulence. A form of nonlinear self-channeling is achieved when the laser power is close to the self-focusing power of air and the transverse dimensions of the pulse are smaller than the coherence diameter of turbulence. In this mode, nonlinear self-focusing counteracts diffraction, and turbulence-induced spreading is greatly reduced. Furthermore, the laser intensity is below the ionization threshold so that multiphoton absorption and plasma defocusing are avoided. Simulations show that the pulse can propagate many Rayleigh lengths (several kilometers) while maintaining a high intensity. In the presence of aerosols, or other extinction mechanisms that deplete laser energy, the pulse can be chirped to maintain the channeling.

  9. Xp11.2 Translocation Renal Cell Carcinoma Diagnosed by Immunohistochemistry and Cytogenetics.

    PubMed

    Dey, Biswajit; Badhe, Bhawana; Govindarajan, Krishna Kumar; Ramesh, Ranjith Arumbakkam

    2016-01-01

    Xp11.2 translocation renal cell carcinomas (TRCCs) are a group of neoplasms with distinct clinical, histopathological appearance, immunohistochemical, and cytogenetic profile. We report a case of Xp11.2 translocation TRCC in an 11-year-old male diagnosed based on immunohistochemistry and fluorescence in situ hybridization.

  10. Explosive Pulsed Power Experiments At The Phillips Laboratory

    DTIC Science & Technology

    1997-06-01

    Weapons and Survivability Directorate Phillips Laboratory Kirtland AFB, NM 87117 J. Graham, W. Sornrnars Albuquerque Division Maxwell Technologies... Phillips Laboratory Kirtland AFB, NM 87117 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10...pulse shaping/impedance matching systems are discussed. Introduction Air Force missions utilizing pulsed power technology increasingly require the

  11. Coordinated Research Program in Pulsed Power Physics.

    DTIC Science & Technology

    1984-12-20

    heated array of Inductive energy storage is attractive in pulsed power 375-/am-diameter thoriated tungsten filaments. At a flia- applications because of...control system electrostatical- ly. It is positioned 0.6 cm above the control grid. The grids and cathode are connected to external power supplies through...energy storage density becomes even larger (by a factor of - 10). One should note that these comparisons do not account for power supplies , cooling

  12. High-power industrial pulsed CO2 laser

    NASA Astrophysics Data System (ADS)

    Levin, G. I.

    1983-12-01

    The use of a pulsed TEA CO2 laser (with maximum average power 1.0 kW; maximum pulse energy 3.5 J; repetition frequency 400-600 Hz; half-width pulse duration 15 microsec; circular-coupling-aperture beam diameter 6, 8, or 12 mm; and beam divergence 10 mrad) in industrial welding applications is investigated experimentally in carbon and stainless steels, Zr, Ti, and Ni of various thicknesses. The power required to melt the metals is found to be about 120-200 W/sq cm, or 5-6 times less than that for CW lasers. It is shown that deep narrow-seam welds with mechanical properties identical to those of the bulk metal can be obtained with little or no intercrystalline corrosion or thermal distortion of the surrounding area. Disadvantages such as the 65-dB noise level, low welding speed, formation of an overlap at the top and a crater at the bottom of the weld, and root porosity are considered the primary limitations on the applicability of the device tested.

  13. Active high-power RF switch and pulse compression system

    DOEpatents

    Tantawi, Sami G.; Ruth, Ronald D.; Zolotorev, Max

    1998-01-01

    A high-power RF switching device employs a semiconductor wafer positioned in the third port of a three-port RF device. A controllable source of directed energy, such as a suitable laser or electron beam, is aimed at the semiconductor material. When the source is turned on, the energy incident on the wafer induces an electron-hole plasma layer on the wafer, changing the wafer's dielectric constant, turning the third port into a termination for incident RF signals, and. causing all incident RF signals to be reflected from the surface of the wafer. The propagation constant of RF signals through port 3, therefore, can be changed by controlling the beam. By making the RF coupling to the third port as small as necessary, one can reduce the peak electric field on the unexcited silicon surface for any level of input power from port 1, thereby reducing risk of damaging the wafer by RF with high peak power. The switch is useful to the construction of an improved pulse compression system to boost the peak power of microwave tubes driving linear accelerators. In this application, the high-power RF switch is placed at the coupling iris between the charging waveguide and the resonant storage line of a pulse compression system. This optically controlled high power RF pulse compression system can handle hundreds of Megawatts of power at X-band.

  14. A new lead-acid battery for high pulse power applications

    NASA Technical Reports Server (NTRS)

    Rowlette, J. J.; Attia, A. I.

    1987-01-01

    The development of new electronically conductive materials which can withstand the environment of the positive plates has made possible the construction of a high pulse power sealed bipolar lead-acid battery. The new battery is described and its advantages over other electrochemical systems are outlined. Performance projections show that the peak specific power of the battery can be as high as 90 kW/kg, and that a specific power of 5 kW/kg can be sustained over several thousand pulses.

  15. Xp11.2 Translocation Renal Cell Carcinoma Diagnosed by Immunohistochemistry and Cytogenetics

    PubMed Central

    Dey, Biswajit; Badhe, Bhawana; Govindarajan, Krishna Kumar; Ramesh, Ranjith Arumbakkam

    2016-01-01

    Xp11.2 translocation renal cell carcinomas (TRCCs) are a group of neoplasms with distinct clinical, histopathological appearance, immunohistochemical, and cytogenetic profile. We report a case of Xp11.2 translocation TRCC in an 11-year-old male diagnosed based on immunohistochemistry and fluorescence in situ hybridization. PMID:27365924

  16. Spectral variation of high power microwave pulse propagating in a self-generated plasma

    NASA Technical Reports Server (NTRS)

    Ren, A.; Kuo, S. P.; Kossey, Paul

    1995-01-01

    A systematic study to understand the spectral variation of a high power microwave pulse propagating in a self-generated plasma is carried out. It includes the theoretical formulation, experimental demonstration, and computer simulations and computer experiments. The experiment of pulse propagation is conducted in a vacuum chamber filled with dry air (approximately 0.2 torr); the chamber is made of a 2 ft. cube of Plexiglas. A rectangular microwave pulse (1 microsec pulse width and 3.27 GHz carrier frequency) is fed into the cube through an S band microwave horn placed at one side of the chamber. A second S-band horn placed at the opposite side of the chamber is used to receive the transmitted pulse. The spectra of the incident pulse and transmitted pulse are then compared. As the power of the incident pulse is only slightly (less than 15%) above the breakdown threshold power of the background air, the peak of the spectrum of the transmitted pulse is upshifted from the carrier frequency 3.27 GHz of the incident pulse. However, as the power of the incident pulse exceeds the breakdown threshold power of the background air by 30%, a different phenomenon appears. The spectrum of the transmitted pulse begins to have two peaks. One is upshifted and the other one downshifted from the single peak location of the incident pulse. The amount of frequency downshift is comparable to that of the upshifted frequency. A theoretical model describing the experiment of pulse propagation in a self-generated plasma is developed. There are excellent agreements between the experimental results and computer simulations based on this theoretical model, which is also used to further carry out computer experiments identifying the role of plasma introduced wave loss on the result of frequency downshift phenomenon.

  17. Ferroelectric switch for a high-power Ka-band active pulse compressor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirshfield, Jay L.

    2013-12-18

    Results are presented for design of a high-power microwave switch for operation at 34.3 GHz, intended for use in an active RF pulse compressor. The active element in the switch is a ring of ferroelectric material, whose dielectric constant can be rapidly changed by application of a high-voltage pulse. As envisioned, two of these switches would be built into a pair of delay lines, as in SLED-II at SLAC, so as to allow 30-MW μs-length Ka-band pulses to be compressed in time by a factor-of-9 and multiplied in amplitude to generate 200 MW peak power pulses. Such high-power pulses couldmore » be used for testing and evaluation of high-gradient mm-wave accelerator structures, for example. Evaluation of the switch design was carried out with an X-band (11.43 GHz) prototype, built to incorporate all the features required for the Ka-band version.« less

  18. PIC simulation of the vacuum power flow for a 5 terawatt, 5 MV, 1 MA pulsed power system

    NASA Astrophysics Data System (ADS)

    Liu, Laqun; Zou, Wenkang; Liu, Dagang; Guo, Fan; Wang, Huihui; Chen, Lin

    2018-03-01

    In this paper, a 5 Terawatt, 5 MV, 1 MA pulsed power system based on vacuum magnetic insulation is simulated by the particle-in-cell (PIC) simulation method. The system consists of 50 100-kV linear transformer drive (LTD) cavities in series, using magnetically insulated induction voltage adder (MIVA) technology for pulsed power addition and transmission. The pulsed power formation and the vacuum power flow are simulated when the system works in self-limited flow and load-limited flow. When the pulsed power system isn't connected to the load, the downstream magnetically insulated transmission line (MITL) works in the self-limited flow, the maximum of output current is 1.14 MA and the amplitude of voltage is 4.63 MV. The ratio of the electron current to the total current is 67.5%, when the output current reached the peak value. When the impedance of the load is 3.0 Ω, the downstream MITL works in the self-limited flow, the maximums of output current and the amplitude of voltage are 1.28 MA and 3.96 MV, and the ratio of the electron current to the total current is 11.7% when the output current reached the peak value. In addition, when the switches are triggered in synchronism with the passage of the pulse power flow, it effectively reduces the rise time of the pulse current.

  19. Pulse compression of a high-power thin disk laser using rod-type fiber amplifiers.

    PubMed

    Saraceno, C J; Heckl, O H; Baer, C R E; Südmeyer, T; Keller, U

    2011-01-17

    We report on two pulse compressors for a high-power thin disk laser oscillator using rod-type fiber amplifiers. Both systems are seeded by a standard SESAM modelocked thin disk laser that delivers 16 W of average power at a repetition rate of 10.6 MHz with a pulse energy of 1.5 μJ and a pulse duration of 1 ps. We discuss two results with different fiber parameters with different trade-offs in pulse duration, average power, damage and complexity. The first amplifier setup consists of a Yb-doped fiber amplifier with a 2200 μm2 core area and a length of 55 cm, resulting in a compressed average power of 55 W with 98-fs pulses at a repetition rate of 10.6 MHz. The second system uses a shorter 36-cm fiber with a larger core area of 4500 μm2. In a stretcher-free configuration we obtained 34 W of compressed average power and 65-fs pulses. In both cases peak powers of > 30 MW were demonstrated at several μJ pulse energies. The power scaling limitations due to damage and self-focusing are discussed.

  20. McDonald XP-85 Airplane in 40x80 foot Wind Tunnel.

    NASA Image and Video Library

    1948-04-08

    Front View of McDonald XP-85 Plan Model. Parasite Airplane designed to be carried in the B-36 bombay (never built) At the time it was the smallest Jet powered airplane. The McDonnell XF-85 Goblin was an American prototype fighter aircraft conceived during World War II by McDonnell Aircraft. It was intended to be deployed from the bomb bay of the giant Convair B-36 bomber as a parasite fighter. The XF-85's intended role was to defend bombers from hostile interceptor aircraft, a need demonstrated during World War II

  1. Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation.

    PubMed

    Choi, Hojong; Woo, Park Chul; Yeom, Jung-Yeol; Yoon, Changhan

    2017-04-04

    A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (-1.8 and -0.96 dB, respectively) compared to that of the HVPA without the power MOSFET linearizer (-2.95 and -3.0 dB, respectively) when 70 and 80 MHz, three-cycle, and 26 dB m input pulse waveforms are applied, respectively. The input 1-dB compression point (an index of linearity) of the HVPA with power MOSFET linearizer (24.17 and 26.19 dB m at 70 and 80 MHz, respectively) at 10 V DC bias voltage was increased compared to that of HVPA without the power MOSFET linearizer (22.03 and 22.13 dB m at 70 and 80 MHz, respectively). To further verify the reduction of the echo harmonic distortion components generated by the ultrasonic transducers, the pulse-echo responses in the pulse-echo instrumentation were compared when using HVPA with and without the power MOSFET linearizer. When three-cycle 26 dB m input power was applied, the second, third, fourth, and fifth harmonic distortion components of a 75 MHz transducer driven by the HVPA with power MOSFET linearizer (-48.34, -44.21, -48.34, and -46.56 dB, respectively) were lower than that of the HVPA without the power MOSFET linearizer (-45.61, -41.57, -45.01, and -45.51 dB, respectively). When five-cycle 20 dB m input

  2. INPIStron switched pulsed power for dense plasma pinches

    NASA Technical Reports Server (NTRS)

    Han, Kwang S.; Lee, Ja H.

    1993-01-01

    The inverse plasma switch INPIStron was employed for 10kJ/40kV capacitor bank discharge system to produce focused dense plasmas in hypocycloidal-pinch (HCP) devices. A single unit and an array of multiple HCP's were coupled as the load of the pulsed power circuit. The geometry and switching plasma dynamics were found advantageous and convenient for commutating the large current pulse from the low impedance transmission line to the low impedance plasma load. The pulse power system with a single unit HCP, the system A, was used for production of high temperature plasma focus and its diagnostics. The radially running down plasma dynamics, revealed in image converter photographs, could be simulated by a simple snow-plow model with a correction for plasma resistivity. The system B with an array of 8-HCP units which forms a long coaxial discharge chamber was used for pumping a Ti-sapphire laser. The intense UV emission from the plasma was frequency shifted with dye-solution jacket to match the absorption band of the Ti crystal laser near 500 nm. An untuned laser pulse energy of 0.6 J/pulse was obtained for 6.4 kJ/40 kV discharge, or near 103 times of the explosion limit of conventional flash lamps. For both systems the advantages of the INPIStron were well demonstrated: a single unit is sufficient for a large current (greater than 50 kA) without increasing the system impedance, highly reliable and long life operation and implied scalability for the high power ranges above I(sub peak) = 1 MA and V(sub hold) = 100 kV.

  3. Applications Performance on NAS Intel Paragon XP/S - 15#

    NASA Technical Reports Server (NTRS)

    Saini, Subhash; Simon, Horst D.; Copper, D. M. (Technical Monitor)

    1994-01-01

    The Numerical Aerodynamic Simulation (NAS) Systems Division received an Intel Touchstone Sigma prototype model Paragon XP/S- 15 in February, 1993. The i860 XP microprocessor with an integrated floating point unit and operating in dual -instruction mode gives peak performance of 75 million floating point operations (NIFLOPS) per second for 64 bit floating point arithmetic. It is used in the Paragon XP/S-15 which has been installed at NAS, NASA Ames Research Center. The NAS Paragon has 208 nodes and its peak performance is 15.6 GFLOPS. Here, we will report on early experience using the Paragon XP/S- 15. We have tested its performance using both kernels and applications of interest to NAS. We have measured the performance of BLAS 1, 2 and 3 both assembly-coded and Fortran coded on NAS Paragon XP/S- 15. Furthermore, we have investigated the performance of a single node one-dimensional FFT, a distributed two-dimensional FFT and a distributed three-dimensional FFT Finally, we measured the performance of NAS Parallel Benchmarks (NPB) on the Paragon and compare it with the performance obtained on other highly parallel machines, such as CM-5, CRAY T3D, IBM SP I, etc. In particular, we investigated the following issues, which can strongly affect the performance of the Paragon: a. Impact of the operating system: Intel currently uses as a default an operating system OSF/1 AD from the Open Software Foundation. The paging of Open Software Foundation (OSF) server at 22 MB to make more memory available for the application degrades the performance. We found that when the limit of 26 NIB per node out of 32 MB available is reached, the application is paged out of main memory using virtual memory. When the application starts paging, the performance is considerably reduced. We found that dynamic memory allocation can help applications performance under certain circumstances. b. Impact of data cache on the i860/XP: We measured the performance of the BLAS both assembly coded and Fortran

  4. Validation of a TFE3 break-apart FISH assay for Xp11.2 translocation renal cell carcinomas.

    PubMed

    Mosquera, Juan-Miguel; Dal Cin, Paola; Mertz, Kirsten D; Perner, Sven; Davis, Ian J; Fisher, David E; Rubin, Mark A; Hirsch, Michelle S

    2011-09-01

    Renal cell carcinomas (RCCs) with an Xp11.2 translocation predominantly affect young patients, and can present at an advanced stage. However, more cases in older patients and incidentally detected cancers at earlier stages are also being identified. As the histology of Xp11.2 RCCs overlaps with clear cell and papillary RCCs, it is not infrequent that Xp11.2 RCCs are overlooked and misdiagnosed. The objective of this study was to validate the use of fluorescence in-situ hybridization (FISH) for identifying Xp11.2 RCCs. One hundred fifty-eight consecutive, unselected renal tumors were evaluated in tissue microarrays, including 109 clear cell RCCs, 20 papillary RCCs, 3 RCCs with mixed papillary and clear cell features, 1 Xp11.2 translocation RCC, 8 chromophobe RCCs, 10 oncocytomas, and 7 angiomyolipomas. FISH evaluation was performed blinded to karyotype data, available in about two-thirds of cases. Furthermore, conventional sections of 4 Xp11.2 RCCs, 4 RCCs with mixed papillary and clear cell features, and 4 cases of alveolar soft part sarcoma (the latter for control purposes) were also assessed by FISH. Break-apart signals were homogeneously identified throughout tumor cells in 2 cases from the tissue microarrays including 1 known Xp11.2 RCC and 1 misdiagnosed Xp11.2 RCC. All conventional sections from the Xp11.2 RCC and alveolar soft part sarcoma cases were positive for the TFE3 rearrangement by FISH. All remaining cases were negative. Our study shows the clinical application of FISH in formalin-fixed, paraffin-embedded tissue for detection of Xp11.2 translocation RCCs and other tumors with this genetic aberration.

  5. Transmission line pulse system for avalanche characterization of high power semiconductor devices

    NASA Astrophysics Data System (ADS)

    Riccio, Michele; Ascione, Giovanni; De Falco, Giuseppe; Maresca, Luca; De Laurentis, Martina; Irace, Andrea; Breglio, Giovanni

    2013-05-01

    Because of the increasing in power density of electronic devices for medium and high power application, reliabilty of these devices is of great interest. Understanding the avalanche behaviour of a power device has become very important in these last years because it gives an indication of the maximum energy ratings which can be seen as an index of the device ruggedness. A good description of this behaviour is given by the static IV blocking characteristc. In order to avoid self heating, very relevant in high power devices, very short pulses of current have to be used, whose value can change from few milliamps up to tens of amps. The most used method to generate short pulses is the TLP (Transmission Line Pulse) test, which is based on charging the equivalent capacitance of a transmission line to high value of voltage and subsequently discharging it onto a load. This circuit let to obtain very short square pulses but it is mostly used for evaluate the ESD capability of semiconductor and, in this environment, it generates pulses of low amplitude which are not high enough to characterize the avalanche behaviour of high power devices . Advanced TLP circuit able to generate high current are usually very expensive and often suffer of distorption of the output pulse. In this article is proposed a simple, low cost circuit, based on a boosted-TLP configuration, which is capable to produce very square pulses of about one hundreds of nanosecond with amplitude up to some tens of amps. A prototype is implemented which can produce pulses up to 20A of amplitude with 200 ns of duration which can characterize power devices up to 1600V of breakdown voltage. Usage of microcontroller based logic make the circuit very flexible. Results of SPICE simulation are provided, together with experimental results. To prove the effectiveness of the circuit, the I-V blocking characteristics of two commercial devices, namely a 600V PowerMOS and a 1200V Trench-IGBT, are measured at different

  6. Solid state pulsed power generator

    DOEpatents

    Tao, Fengfeng; Saddoughi, Seyed Gholamali; Herbon, John Thomas

    2014-02-11

    A power generator includes one or more full bridge inverter modules coupled to a semiconductor opening switch (SOS) through an inductive resonant branch. Each module includes a plurality of switches that are switched in a fashion causing the one or more full bridge inverter modules to drive the semiconductor opening switch SOS through the resonant circuit to generate pulses to a load connected in parallel with the SOS.

  7. Pulse Power Applications of Flux Compression Generators

    DTIC Science & Technology

    1981-06-01

    Characteristics are presented for two different types of explosive driven flux compression generators and a megavolt pulse transformer. Status reports are given for rail gun and plasma focus programs for which the generators serve as power sources.

  8. Hybrid circuit achieves pulse regeneration with low power drain

    NASA Technical Reports Server (NTRS)

    Cancro, C. A.

    1965-01-01

    Hybrid tunnel diode-transistor circuit provides a solid-state, low power drain pulse regenerator, frequency limiter, or gated oscillator. When the feedback voltage exceeds the input voltage, the circuit functions as a pulse normalizer or a frequency limiter. If the circuit is direct coupled, it functions as a gated oscillator.

  9. Research on laser detonation pulse circuit with low-power based on super capacitor

    NASA Astrophysics Data System (ADS)

    Wang, Hao-yu; Hong, Jin; He, Aifeng; Jing, Bo; Cao, Chun-qiang; Ma, Yue; Chu, En-yi; Hu, Ya-dong

    2018-03-01

    According to the demand of laser initiating device miniaturization and low power consumption of weapon system, research on the low power pulse laser detonation circuit with super capacitor. Established a dynamic model of laser output based on super capacitance storage capacity, discharge voltage and programmable output pulse width. The output performance of the super capacitor under different energy storage capacity and discharge voltage is obtained by simulation. The experimental test system was set up, and the laser diode of low power pulsed laser detonation circuit was tested and the laser output waveform of laser diode in different energy storage capacity and discharge voltage was collected. Experiments show that low power pulse laser detonation based on super capacitor energy storage circuit discharge with high efficiency, good transient performance, for a low power consumption requirement, for laser detonation system and low power consumption and provide reference light miniaturization of engineering practice.

  10. An innovative high-power constant-current pulsed-arc power-supply for a high-density pulsed-arc-plasma ion-source using a LaB6-filament.

    PubMed

    Ueno, A; Oguri, H; Ikegami, K; Namekawa, Y; Ohkoshi, K; Tokuchi, A

    2010-02-01

    An innovative high-power constant-current (CC) pulsed-arc (PA) power-supply (PS) indispensable for a high-density PA plasma ion-source using a lanthanum hexaboride (LaB(6)) filament was devised by combining a constant-voltage (CV) PA-PS, which is composed of an insulated gate bipolar transistor (IGBT) switch, a CV direct-current (dc) PS and a 270 mF capacitor with a CC-PA-PS, which is composed of an IGBT-switch, a CC-dc-PS and a 400 microH inductor, through the inductor. The hybrid-CC-PA-PS succeeded in producing a flat arc-pulse with a peak power of 56 kW (400 A x 140 V) and a duty factor of more than 1.5% (600 micros x 25 Hz) for Japan Proton Accelerator Research Complex (J-PARC) H(-) ion-source stably. It also succeeded in shortening the 99% rising-time of the arc-pulse-current to about 20 micros and tilting up or down the arc-pulse-current arbitrarily and almost linearly by changing the setting voltage of its CV-dc-PS.

  11. High single-spatial-mode pulsed power from 980 nm emitting diode lasers

    NASA Astrophysics Data System (ADS)

    Hempel, Martin; Tomm, Jens W.; Elsaesser, Thomas; Bettiati, Mauro

    2012-11-01

    Single-spatial-mode pulsed powers as high as 13 W and 20 W in 150 and 50 ns pulses, respectively, are reported for 980 nm emitting lasers. In terms of energy, single-spatial-mode values of up to 2 μJ within 150 ns pulses are shown. In this high-power pulsed operation, the devices shield themselves from facet degradation, being the main degradation source in continuous wave (cw) operation. Our results pave the way towards additional applications while employing available standard devices, which have originally been designed as very reliable cw fiber pumps.

  12. Acousto-optical imaging using a powerful long pulse laser

    NASA Astrophysics Data System (ADS)

    Rousseau, Guy; Blouin, Alain; Monchalin, Jean-Pierre

    2008-06-01

    Acousto-optical imaging is an emerging biodiagnostic technique which provides an optical spectroscopic signature and a spatial localization of an optically absorbing target embedded in a strongly scattering medium. The transverse resolution of the technique is determined by the lateral extent of ultrasound beam focal zone while the axial resolution is obtained by using short ultrasound pulses. Although very promising for medical diagnostic, the practical application of this technique is presently limited by its poor sensitivity. Moreover, any method to enhance the signal-to-noise ratio must obviously satisfy the in vivo safety limits regarding the acceptable power level of both the ultrasonic pressure wave and the laser beam. In this paper, we propose to improve the sensitivity by using a pulsed single-frequency laser source to raise the optical peak power applied to the scattering medium and to collect more ultrasonically tagged photons. Such a laser source also allows illuminating the tissues mainly during the transit time of the ultrasonic wave to maintain the average optical power below the maximum permissible exposure. In our experiment, a single-frequency Nd:YAG laser emitting 500-μs pulses with a peak power superior to 100 W was used. Photons were tagged in few-cm thick optical phantoms with tone bursts generated by an ultrasonic transducer. Tagged photons were detected with a GaAs photorefractive interferometer characterized by a large optical etendue to process simultaneously a large number of speckle grains. When pumped by high intensity laser pulses, such an interferometer also provides the fast response time essential to obtain an apparatus insensitive to the speckle decorrelation due to mechanical vibrations or tissues movements. The use of a powerful long pulse laser appears promising to enhance the signal level in ultrasound modulated optical imaging. When combined with a photorefractive interferometer of large optical etendue, such a source could

  13. Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation

    PubMed Central

    Choi, Hojong; Woo, Park Chul; Yeom, Jung-Yeol; Yoon, Changhan

    2017-01-01

    A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (−1.8 and −0.96 dB, respectively) compared to that of the HVPA without the power MOSFET linearizer (−2.95 and −3.0 dB, respectively) when 70 and 80 MHz, three-cycle, and 26 dBm input pulse waveforms are applied, respectively. The input 1-dB compression point (an index of linearity) of the HVPA with power MOSFET linearizer (24.17 and 26.19 dBm at 70 and 80 MHz, respectively) at 10 V DC bias voltage was increased compared to that of HVPA without the power MOSFET linearizer (22.03 and 22.13 dBm at 70 and 80 MHz, respectively). To further verify the reduction of the echo harmonic distortion components generated by the ultrasonic transducers, the pulse-echo responses in the pulse-echo instrumentation were compared when using HVPA with and without the power MOSFET linearizer. When three-cycle 26 dBm input power was applied, the second, third, fourth, and fifth harmonic distortion components of a 75 MHz transducer driven by the HVPA with power MOSFET linearizer (−48.34, −44.21, −48.34, and −46.56 dB, respectively) were lower than that of the HVPA without the power MOSFET linearizer (−45.61, −41.57, −45.01, and −45.51 dB, respectively). When five

  14. Cyclic and Torsional Fatigue Resistance of XP-endo Shaper and TRUShape Instruments.

    PubMed

    Silva, Emmanuel João Nogueira Leal; Vieira, Victor Talarico Leal; Belladonna, Felipe Gonçalves; Zuolo, Arthur de Siqueira; Antunes, Henrique Dos Santos; Cavalcante, Daniele Moreira; Elias, Carlos Nelson; De-Deus, Gustavo

    2018-01-01

    The purpose of this study was to evaluate the cyclic and torsional fatigue resistance of the XP-endo Shaper (FKG Dentaire, La Chaux-de-Fonds, Switzerland) and TRUShape (Dentsply Tulsa Dental Specialties, Tulsa, OK) instruments. Twenty XP-endo Shaper (30/0.01) instruments and 20 TRUShape (30/0.06v) instruments were used. Cyclic fatigue resistance was tested by measuring the number of cycles and time to fracture in an artificial stainless steel canal with a 60° angle and a 5-mm radius of curvature (n = 10). The torque and angle of rotation at failure of new instruments (n = 10) were measured according to ISO 3630-1. The fracture surface of all fragments was examined with a scanning electron microscope. Results were statistically analyzed using the Student t test at a significance level of P < .05. The XP-endo Shaper instruments showed a significantly longer number of cycles to fracture and time to failure in seconds than the TRUShape instruments (P < .05). The XP-endo Shaper also presented a lower maximum torque load (P < .05) but a significantly higher angular rotation to fracture than TRUShape (P < .05). The XP-endo Shaper instruments showed a higher cyclic fatigue resistance and angle of rotation to fracture but lower torque to failure than TRUShape instruments. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Electron-Beam Switches For A High Peak Power Sled-II Pulse Compressor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirshfield, Jay, L.

    2015-12-02

    Omega-P demonstrated triggered electron-beam switches on the L=2 m dual-delay-line X-band pulse compressor at Naval Research Laboratory (NRL). In those experiments, with input pulses of up to 9 MW from the Omega-P/NRL X-band magnicon, output pulses having peak powers of 140-165 MW and durations of 16-20 ns were produced, with record peak power gains M of 18-20. Switch designs are described based on the successful results that should be suitable for use with the existing SLAC SLED-II delay line system, to demonstrate C=9, M=7, and n>>78%, yielding 173ns compressed pulses with peak powers up to 350MW with input of amore » single 50-MW.« less

  16. High-power noise-like pulse generation using a 1.56-µm all-fiber laser system.

    PubMed

    Lin, Shih-Shian; Hwang, Sheng-Kwang; Liu, Jia-Ming

    2015-07-13

    We demonstrated an all-fiber, high-power noise-like pulse laser system at the 1.56-µm wavelength. A low-power noise-like pulse train generated by a ring oscillator was amplified using a two-stage amplifier, where the performance of the second-stage amplifier determined the final output power level. The optical intensity in the second-stage amplifier was managed well to avoid not only the excessive spectral broadening induced by nonlinearities but also any damage to the device. On the other hand, the power conversion efficiency of the amplifier was optimized through proper control of its pump wavelength. The pump wavelength determines the pump absorption and therefore the power conversion efficiency of the gain fiber. Through this approach, the average power of the noise-like pulse train was amplified considerably to an output of 13.1 W, resulting in a power conversion efficiency of 36.1% and a pulse energy of 0.85 µJ. To the best of our knowledge, these amplified pulses have the highest average power and pulse energy for noise-like pulses in the 1.56-µm wavelength region. As a result, the net gain in the cascaded amplifier reached 30 dB. With peak and pedestal widths of 168 fs and 61.3 ps, respectively, for the amplified pulses, the pedestal-to-peak intensity ratio of the autocorrelation trace remains at the value of 0.5 required for truly noise-like pulses.

  17. Increasing power and amplified spontaneous emission suppression for weak signal amplification in pulsed fiber amplifier

    NASA Astrophysics Data System (ADS)

    Luo, Yi; Zhang, Hanwei; Wang, Xiaolin; Su, Rongtao; Ma, Pengfei; Zhou, Pu; Jiang, Zongfu

    2017-10-01

    In the pulsed fiber amplifiers with repetition frequency of several tens kHz, amplified spontaneous emission (ASE) is easy to build up because of the low repetition frequency and weak pulse signal. The ASE rises the difficulty to amplify the weak pulse signal effectively. We have demonstrated an all-fiber preamplifier stage structure to amplify a 40 kHz, 10 ns bandwidth (FWHM) weak pulse signal (299 μW) with center wavelength of 1062 nm. Compared synchronous pulse pump with continuous wave(CW) pump, the results indicate that synchronous pulse pump shows the better capability of increasing the output power than CW pump. In the condition of the same pump power, the output power of synchronous pulse pump is twice as high as CW pump. In order to suppress ASE, a longer gain fiber is utilized to reabsorb the ASE in which the wavelength is shorter than 1062nm. We amplified weak pulse signal via 0.8 m and 2.1 m gain fiber in synchronous pulse pump experiments respectively, and more ASE in the output spectra are observed in the 0.8 m gain fiber system. Due to the weaker ASE and consequent capability of higher pump power, the 2.1 m gain fiber is capable to achieve higher output power than shorter fiber. The output power of 2.1 m gain fiber case is limited by pump power.

  18. Combinatorial pulse position modulation for power-efficient free-space laser communications

    NASA Technical Reports Server (NTRS)

    Budinger, James M.; Vanderaar, M.; Wagner, P.; Bibyk, Steven

    1993-01-01

    A new modulation technique called combinatorial pulse position modulation (CPPM) is presented as a power-efficient alternative to quaternary pulse position modulation (QPPM) for direct-detection, free-space laser communications. The special case of 16C4PPM is compared to QPPM in terms of data throughput and bit error rate (BER) performance for similar laser power and pulse duty cycle requirements. The increased throughput from CPPM enables the use of forward error corrective (FEC) encoding for a net decrease in the amount of laser power required for a given data throughput compared to uncoded QPPM. A specific, practical case of coded CPPM is shown to reduce the amount of power required to transmit and receive a given data sequence by at least 4.7 dB. Hardware techniques for maximum likelihood detection and symbol timing recovery are presented.

  19. Heat input and accumulation for ultrashort pulse processing with high average power

    NASA Astrophysics Data System (ADS)

    Finger, Johannes; Bornschlegel, Benedikt; Reininghaus, Martin; Dohrn, Andreas; Nießen, Markus; Gillner, Arnold; Poprawe, Reinhart

    2018-05-01

    Materials processing using ultrashort pulsed laser radiation with pulse durations <10 ps is known to enable very precise processing with negligible thermal load. However, even for the application of picosecond and femtosecond laser radiation, not the full amount of the absorbed energy is converted into ablation products and a distinct fraction of the absorbed energy remains as residual heat in the processed workpiece. For low average power and power densities, this heat is usually not relevant for the processing results and dissipates into the workpiece. In contrast, when higher average powers and repetition rates are applied to increase the throughput and upscale ultrashort pulse processing, this heat input becomes relevant and significantly affects the achieved processing results. In this paper, we outline the relevance of heat input for ultrashort pulse processing, starting with the heat input of a single ultrashort laser pulse. Heat accumulation during ultrashort pulse processing with high repetition rate is discussed as well as heat accumulation for materials processing using pulse bursts. In addition, the relevance of heat accumulation with multiple scanning passes and processing with multiple laser spots is shown.

  20. Self-Powered Real-Time Arterial Pulse Monitoring Using Ultrathin Epidermal Piezoelectric Sensors.

    PubMed

    Park, Dae Yong; Joe, Daniel J; Kim, Dong Hyun; Park, Hyewon; Han, Jae Hyun; Jeong, Chang Kyu; Park, Hyelim; Park, Jung Gyu; Joung, Boyoung; Lee, Keon Jae

    2017-10-01

    Continuous monitoring of an arterial pulse using a pressure sensor attached on the epidermis is an important technology for detecting the early onset of cardiovascular disease and assessing personal health status. Conventional pulse sensors have the capability of detecting human biosignals, but have significant drawbacks of power consumption issues that limit sustainable operation of wearable medical devices. Here, a self-powered piezoelectric pulse sensor is demonstrated to enable in vivo measurement of radial/carotid pulse signals in near-surface arteries. The inorganic piezoelectric sensor on an ultrathin plastic achieves conformal contact with the complex texture of the rugged skin, which allows to respond to the tiny pulse changes arising on the surface of epidermis. Experimental studies provide characteristics of the sensor with a sensitivity (≈0.018 kPa -1 ), response time (≈60 ms), and good mechanical stability. Wireless transmission of detected arterial pressure signals to a smart phone demonstrates the possibility of self-powered and real-time pulse monitoring system. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Wavelength stabilized high pulse power laser diodes for automotive LiDAR

    NASA Astrophysics Data System (ADS)

    Knigge, A.; Klehr, A.; Wenzel, H.; Zeghuzi, A.; Fricke, J.; Maaßdorf, A.; Liero, A.; Tränkle, G.

    2018-03-01

    Diode lasers generating optical pulses with high peak power and lengths in the nanosecond range are key components of systems for free-space communication, metrology, material processing, spectroscopy, and light detection and ranging (LiDAR) as needed for object detection and autonomous driving. Automotive LiDAR systems demand additionally a good beam quality and low wavelength shift with temperature due to the wide operating temperature span. We present here internally wavelength stabilized lasers emitting ns optical pulses from an emission aperture between 30 μm and 100 μm with peak powers of tens of Watts at wavelengths around 905 nm. The vertical structure based on AlGaAs (confinement and cladding layers) and InGaAs (active quantum well) is especially optimized for pulsed operation with respect to the implementation of a surface Bragg grating with a high reflectivity. The fabricated 6 mm long distributed Bragg reflector (DBR) broad area (BA) lasers are electrically driven by an in-house developed high-speed unit generating 3 to 10 ns long nearly rectangular shaped current pulses with amplitudes of up to 250 A. Such lasers emit optical pulses with a peak power of more than 30 W at 95 A pulse current up to a temperature of 85°C with a wavelength shift as low as 65 pm/K and a lateral beam propagation factor less than 10. The influence of the lateral aperture width and the pulse length on the beam quality will be shown. A monolithic integration of 3 DBR BA lasers on a single chip whose emission can be combined into a single beam raises the output power to more than 100 W.

  2. Camelot-a novel concept for a multiterawatt pulse power generator for single pulse, burst, or repetetion rate operation. Special report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, A.G.

    1981-04-01

    Superpower pulse generators are fast establishing themselves internationally as candidates for employment in a wide variety of military applications including electronic warfare and jamming, high energy beam weapons, and nuclear weapons effects simulation. Unfortunately, existing multimegajoule pulse power generators such as AURORA do not satisfy many Department of Defense goals for field-adaptable weapon systems-for example, repetition (rep) rate operation, high reliabilty, long life, ease of operation, and low maintenance. The Camelot concept is a multiterawatt rep ratable pulse power source, adaptable to a wide range of output parameters-both charged particles and photons. An analytical computer model has been developed tomore » predict the power flowing through the device. A 5-year development program, culminating in a source region electromagnetic pulse simulator, is presented.« less

  3. Development of Compact Ozonizer with High Ozone Output by Pulsed Power

    NASA Astrophysics Data System (ADS)

    Tanaka, Fumiaki; Ueda, Satoru; Kouno, Kanako; Sakugawa, Takashi; Akiyama, Hidenori; Kinoshita, Youhei

    Conventional ozonizer with a high ozone output using silent or surface discharges needs a cooling system and a dielectric barrier, and therefore becomes a large machine. A compact ozonizer without the cooling system and the dielectric barrier has been developed by using a pulsed power generated discharge. The wire to plane electrodes made of metal have been used. However, the ozone output was low. Here, a compact and high repetition rate pulsed power generator is used as an electric source of a compact ozonizer. The ozone output of 6.1 g/h and the ozone yield of 86 g/kWh are achieved at 500 pulses per second, input average power of 280 W and an air flow rate of 20 L/min.

  4. Renal cell carcinoma associated with Xp11.2 translocations, report of a case.

    PubMed

    Jing, Hongbiao; Tai, Yanhong; Xu, Dazhou; Yang, Fan; Geng, Ming

    2010-07-01

    Renal cell carcinomas (RCCs) associated with Xp11.2 translocations (Xp11.2 translocation RCCs) are rare and occur predominantly in children and adolescents. A case of such tumor in a 12-year boy is reported. Grossly the cut surface of the ill-defined mass was polychromatic, containing areas of hemorrhage and necrosis. Microscopically, the tumor was composed of epithelioid cells with clear to weakly eosinophilic cytoplasm arranged in nested, alveolar, and pseudopapillary formations. Immunohistochemically, the neoplastic cells were positive for transcription factor E3 and CD10. We concluded that this case was an Xp11.2 translocation RCC. Copyright 2010 Elsevier Inc. All rights reserved.

  5. Investigation of a high power electromagnetic pulse source.

    PubMed

    Wang, Yuwei; Chen, Dongqun; Zhang, Jiande; Cao, Shengguang; Li, Da; Liu, Chebo

    2012-09-01

    A high power electromagnetic pulse source with a resonant antenna driven by a compact power supply was investigated in this paper. To match the impedance of the resonant antenna and initial power source, a compact power conditioning circuit based on electro exploding opening switch (EEOS) and pulsed transformer was adopted. In the preliminary experiments, an impulse capacitor was used to drive the system. With the opening of the EEOS at the current of 15 kA flowing trough the primary of the transformer, the resonant antenna was rapidly charged to about -370 kV within a time of about 100 ns. When the switch in the resonant antenna closed at the charging voltage of about -202 kV, the peak intensity of the detected electric field at a distance of about 10 m from the center of the source was 7.2 kV∕m. The corresponding peak power of the radiated electromagnetic field reached 76 MW, while the total radiated electromagnetic energy was about 0.65 J. The total energy efficiency of the resonant antenna was about 22% which can be improved by increasing the closing rapidity of the switch in the antenna.

  6. Generation of High-Power High-Intensity Short X-Ray Free-Electron-Laser Pulses

    DOE PAGES

    Guetg, Marc W.; Lutman, Alberto A.; Ding, Yuantao; ...

    2018-01-03

    X-ray free-electron lasers combine a high pulse power, short pulse length, narrow bandwidth, and high degree of transverse coherence. Any increase in the photon pulse power, while shortening the pulse length, will further push the frontier on several key x-ray free-electron laser applications including single-molecule imaging and novel nonlinear x-ray methods. This Letter shows experimental results at the Linac Coherent Light Source raising its maximum power to more than 300% of the current limit while reducing the photon pulse length to 10 fs. As a result, this was achieved by minimizing residual transverse-longitudinal centroid beam offsets and beam yaw andmore » by correcting the dispersion when operating over 6 kA peak current with a longitudinally shaped beam.« less

  7. Generation of High-Power High-Intensity Short X-Ray Free-Electron-Laser Pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guetg, Marc W.; Lutman, Alberto A.; Ding, Yuantao

    X-ray free-electron lasers combine a high pulse power, short pulse length, narrow bandwidth, and high degree of transverse coherence. Any increase in the photon pulse power, while shortening the pulse length, will further push the frontier on several key x-ray free-electron laser applications including single-molecule imaging and novel nonlinear x-ray methods. This Letter shows experimental results at the Linac Coherent Light Source raising its maximum power to more than 300% of the current limit while reducing the photon pulse length to 10 fs. As a result, this was achieved by minimizing residual transverse-longitudinal centroid beam offsets and beam yaw andmore » by correcting the dispersion when operating over 6 kA peak current with a longitudinally shaped beam.« less

  8. Force Tests of a 1/5-Scale Model of the McDonnell XP-85 Airplane with Conventional Tail Assembly in the Langley Free-Flight Tunnel

    NASA Technical Reports Server (NTRS)

    Paulson, John W.; Johnson, Joseph L.

    1947-01-01

    At the request of the Air Materiel Command, Army Air Forces an investigation of the low-speed, power-off stability and control characteristics of the McDonnell XP-85 airplane is being conducted in the Langley free-flight tunnel. The XP-85 airplane is a parasite fighter carried in a bomb bay of the B-36 airplane. As a part of the investigation a few force tests were made of a 1/5 scale model of the XP-85 with a conventional tail assembly installed in place of the original design five-unit tail assembly. The total area of the conventional assembly was approximately 80 percent of the area of the five-unit assembly. The results of this investigation showed that the conventional tail assembly gave about the same longitudinal stability characteristics as the original configuration and improved the directional and lateral stability.

  9. Effects of pulse frequency of input power on the physical and chemical properties of pulsed streamer discharge plasmas in water

    NASA Astrophysics Data System (ADS)

    Ruma; Lukes, P.; Aoki, N.; Spetlikova, E.; Hosseini, S. H. R.; Sakugawa, T.; Akiyama, H.

    2013-03-01

    A repetitive pulsed-power modulator, which employs a magnetic pulse compression circuit with a high-speed thyristor switch, was used to study the effects of the pulse repetition rate of input power on the physical and chemical properties of pulsed discharges in water. Positive high-voltage pulses of 20 kV with repetition rates of up to 1 kHz were used to generate a discharge in water using the point-to-plane electrode geometry. By varying the pulse repetition rate, two distinct modes of the discharge plasma were formed in water. The first mode was characterized by the formation of a corona-like discharge propagating through water in the form of streamer channels. The second mode was formed typically above 500 Hz, when the formation of streamer channels in water was suppressed and all plasmas occurred inside a spheroidal aggregate of very fine gas bubbles surrounding the tip of the high-voltage electrode. The production of hydrogen peroxide, degradation of organic dye Acid Orange 7 (AO7) and inactivation of bacteria Escherichia coli by the discharge in water were studied under different discharge plasma modes in dependence on the pulse repetition rate of input power. The efficiency of both chemical and biocidal processes induced by the plasma in water decreased significantly with pulse repetition rates above 500 Hz.

  10. Clinicopathologic Characteristics and Prognosis of Xp11.2 Translocation Renal Cell Carcinoma: Multicenter, Propensity Score Matching Analysis.

    PubMed

    Choo, Min Soo; Jeong, Chang Wook; Song, Cheryn; Jeon, Hwang Gyun; Seo, Seong Il; Hong, Sung Kyu; Byun, Seok-Soo; Chung, Jin Soo; Hong, Sung-Hoo; Hwang, Eu Chang; Kim, Hyeon Hoe; Kwak, Cheol

    2017-10-01

    We evaluated the clinicopathologic characteristics and prognosis of Xp11.2 translocation (Xp11.2t) renal cell carcinoma (RCC) from a multicenter study and compare them with clear-cell RCC using a propensity score matching analysis. Between 2004 and 2013, 8384 consecutive patients from 7 institutions who were diagnosed with RCC were reviewed, and the pathologically confirmed Xp11.2t cases were enrolled. The oncological outcomes of Xp11.2t were compared with those of clear-cell RCC by selecting matched cases using 1:3 propensity score matching methods in a precollected clear-cell RCC data set from our hospital. The patients were divided into 2 subgroups on the basis of age of onset, either before (early) or after (late) 45 years old. Xp11.2t was found in 61 cases, corresponding to 0.72% of RCC cases for the 10 years. The mean age was 38.2 ± 19.4 years, and the mean tumor size was 6.2 ± 3.9 cm. The Xp11.2t cases were at more advanced stages and showed tendencies to involve lymph nodes at diagnosis. After the matching, there were no significant differences in recurrence-free and overall survival compared with clear-cell RCC. The age of incidence for Xp11.2t had a bimodal distribution, which was most common in the 30s and smaller peak in the 60s. Xp11.2t corresponded to a significantly worse prognosis for overall survival in late onset (after 45 years) subgroup (P = .038; hazard ratio, 3.199; 95% confidence interval, 1.065-9.609). This neoplasm has more aggressive clinicopathologic features at diagnosis. In older patients with onset age > 45 years, Xp11.2t showed a significantly worse prognosis than clear-cell RCC. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Research on improvement of power quality of Micro - grid based on SVG pulse load

    NASA Astrophysics Data System (ADS)

    Lv, Chuang; Xie, Pu

    2017-05-01

    Pulse load will make the micro-grid public bus power to produce a high peak pulse due to its cyclical pulsation characteristics,, and make the micro-grid voltage fluctuations, frequency fluctuations, voltage and current distortion, power factor reduction and other adverse effects. In order to suppress the adverse effects of the pulse load on the microgrid and improve the power quality of the microgrid, this paper established the SVG simulation model in Matlab / Simulink environment, the superiority of SVG is verified by comparing the improvement of power quality before and after adding the SVG to microgrid system. The results show that the SVG model can suppress the adverse effects effectively of the pulse load on the microgrid, which is of great value and significance to the reactive power compensation and harmonic suppression of the microgrid.

  12. Self-focusing Distance of Very High Power Laser Pulses

    NASA Astrophysics Data System (ADS)

    Fibich, Gadi; Eisenmann, Shmuel; Ilan, Boaz; Erlich, Yossi; Fraenkel, Moshe; Henis, Zohar; Gaeta, Alexander L.; Zigler, Arie

    2005-07-01

    We show numerically for continuous-wave beams and experimentally for femtosecond pulses propagating in air, that the collapse distance of intense laser beams in a bulk Kerr medium scales as 1/P^1/2 for input powers P that are moderately above the critical power for self focusing, but that at higher powers the collapse distance scales as 1/P.

  13. High average/peak power linearly polarized all-fiber picosecond MOPA seeded by mode-locked noise-like pulses

    NASA Astrophysics Data System (ADS)

    Yu, H. L.; Ma, P. F.; Tao, R. M.; Wang, X. L.; Zhou, P.; Chen, J. B.

    2015-06-01

    The characteristics of mode-locked noise-like pulses generated from a passively mode-locked fiber oscillator are experimentally investigated. By carefully adjusting the two polarization controllers, stable mode-locked noise-like pulse emission with a high radio frequency signal/noise ratio of  >55 dB is successfully achieved, ensuring the safety and possibility of high power amplification. To investigate the amplification characteristics of such pulses, one all-fiber master oscillator power amplifier (MOPA) is built to boost the power and energy of such pulses. Amplified noise-like pulses with average output power of 423 W, repetition rate of 18.71 MHz, pulse energy of 22.61 μJ, pulse duration of 72.1 ps and peak power of 314 kW are obtained. Near diffraction-limited beam is also demonstrated with M2 factor measured at full power operation of ~1.2 in the X and Y directions. The polarization extinction ratio at output power of 183 W is measured to be ~13 dB. To the best of our knowledge, this is the first demonstration of high-power amplification of noise-like pulses and the highest peak power ever reported in all-fiber picosecond MOPAs. The temporal self-compression process of such pulses and high peak power when amplified make it an ideal pump source for generation of high-power supercontinuum. Other potential applications, such as material processing and optical coherent tomography, could also be foreseen.

  14. Dynamic Contrast-Enhanced CT Characterization of Xp11.2 Translocation/TFE3 Gene Fusions versus Papillary Renal Cell Carcinomas.

    PubMed

    He, Jian; Zhou, Kefeng; Zhu, Bin; Zhang, Gutian; Li, Xiaogong; Guo, Hongqian; Gan, Weidong; Zhou, Zhengyang; Liu, Tian

    2015-01-01

    To compare the differences of CT characteristics between renal cell carcinomas (RCCs) associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 RCCs) and papillary cell renal cell carcinomas (PRCCs). CT images and clinical records of 64 patients (25 Xp11.2 RCCs, 15 type 1 and 24 type 2 PRCCs) were analyzed and compared retrospectively. Xp11.2 RCC more frequently affected young (30.7 ± 8.7 years) women (16/25, 64%) with gross hematuria (12/25, 48%), while PRCC more frequently involved middle-aged (54.8 ± 11.1 years) men (28/39, 71.8%) asymptomatically. Xp11.2 RCC tended to be heterogeneous density with some showing circular calcification. Lesion sizes of Xp11.2 RCC (5.4 ± 2.2 cm) and type 2 PRCC (5.7 ± 2.5 cm) were significantly larger than that of type 1 PRCC (3.8 ± 1.8 cm). Xp11.2 RCC contained more cystic components (22/25, 88%) than type 1 PRCC (all solid) and type 2 PRCC (9/24, 36.0%). Type 1 PRCC (13/15, 86.7%) and Xp11.2 RCC (21/25, 84.0%) showed more clear boundary than type 2 PRCC (12/24, 50.0%). CT features including diameter, boundary, attenuation, nature, and circular calcification of the tumor, combined with demographic information and symptoms, may be useful to differentiate Xp11.2 RCC from different subtypes of PRCC.

  15. Location interval at Xp22.3 for X-linked chondrodysplasia punctata

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheffield, L.; Hutchison, W.; Holloway, A.

    1994-09-01

    The literature shows that there is a gene for chondropdysplasia punctata (CDP) located at Xp22.3 from the study of chromosomal rearrangements involving Xp. It is also suspected that there are genes for short stature and mental retardation nearby. Petit has described a family of brachytelephalangic CDP that was due to a submicroscopic interstitial deletion of Xp22.3. Symmetrical (mild) CDP seems to be identical to brachytelephalangic CDP clinically, has variable features of short stature and mental retardation, and has a preponderance of affected males. We describe results using DNA probes from Xp22.3 in 10 patients with radiologically proven symmetrical CDP. Othermore » known genes in this region have a high proportion of deletions as we screened our patients for deletions in DXYS20, MIC2, PABX, DXYS159X, DXS283, DXS285, J502(PCR), DXS31, DXS43 (listed distally to proximally). No deletions were found. We have also studied a fetus with proven CDP who has a X,Y translocation (46,V,t(X;Y)(p22.3;q12)mat). This patient was deleted for all distal probes up to J502(PCR). It is not yet known where the breakpoint lies but it may be just proximal to the CDP gene. The results of the 10 symmetrical CDPs and the X;Y translocation fetus are presented with further definition of the X chromosomal breakpoint in the translocation.« less

  16. MDCT findings of renal cell carcinoma associated with Xp11.2 translocation and TFE3 gene fusion and papillary renal cell carcinoma.

    PubMed

    Woo, Sungmin; Kim, Sang Youn; Lee, Myoung Seok; Moon, Kyung Chul; Kim, See Hyung; Cho, Jeong Yeon; Kim, Seung Hyup

    2015-03-01

    OBJECTIVE. The purpose of this study was to compare the MDCT features of renal cell carcinoma (RCC) associated with Xp11.2 translocation and TFE3 gene fusion (Xp11 RCC) and papillary RCC. MATERIALS AND METHODS. The study included 19 and 39 patients with histologically proven Xp11 RCC and papillary RCC, respectively, who underwent multiphase renal MDCT before nephrectomy. CT findings were compared between Xp11 RCC and papillary RCC using the Student t test and chi-square test. Subgroup analyses of small (< 4 cm) renal masses for these features were performed. RESULTS. Patients with Xp11 RCC were younger (p < 0.001), and it was more prevalent in women (p = 0.007). Tumor size was greater in Xp11 RCC (p = 0.004) and more common in cystic change (p < 0.001). Calcification and unenhanced high-attenuating areas were more frequent in Xp11 RCC (p = 0.001 and 0.026, respectively). Xp11 RCCs were more prevalent in lymph node and distant metastasis (p < 0.001 and p = 0.031, respectively). Xp11 RCC and papillary RCC showed no significant difference in epicenter, margin, and venous and collecting duct invasion (p = 0.403-1.000). Although Xp11 RCC and papillary RCC had lower attenuation than the renal cortex on corticomedullary and early excretory phases (p < 0.001), only Xp11 RCCs were hyperattenuating to the cortex on the unenhanced phase (p < 0.001). Xp11 RCCs had significantly higher attenuation compared with papillary RCCs on all phases (p ≤ 0.02). Regarding small masses, cystic change, calcification, and lymph node metastasis were still more frequent in Xp11 RCCs (p ≤ 0.016). CONCLUSION. Greater size, more cystic change, calcification, high-attenuating areas on unenhanced imaging, and lymph node and distant metastasis were helpful for differentiating Xp11 RCC from papillary RCC.

  17. All-fiber high-power monolithic femtosecond laser at 1.59 µm with 63-fs pulse width

    NASA Astrophysics Data System (ADS)

    Hekmat, M. J.; Omoomi, M.; Gholami, A.; Yazdabadi, A. Bagheri; Abdollahi, M.; Hamidnejad, E.; Ebrahimi, A.; Normohamadi, H.

    2018-01-01

    In this research, by adopting an alternative novel approach to ultra-short giant pulse generation which basically originated from difficulties with traditional employed methods, an optimized Er/Yb co-doped double-clad fiber amplifier is applied to boost output average power of single-mode output pulses to a high level of 2-W at 1.59-µm central wavelength. Output pulses of approximately 63-fs pulse width at 52-MHz repetition rate are obtained in an all-fiber monolithic laser configuration. The idea of employing parabolic pulse amplification for stretching output pulses together with high-power pulse amplification using Er/Yb co-doped active fibers for compressing and boosting output average power plays crucial role in obtaining desired results. The proposed configuration enjoys massive advantages over previously reported literature which make it well-suited for high-power precision applications such as medical surgery. Detailed dynamics of pulse stretching and compressing in active fibers with different GVD parameters are numerically and experimentally investigated.

  18. A low-power high-speed ultra-wideband pulse radio transmission system.

    PubMed

    Wei Tang; Culurciello, E

    2009-10-01

    We present a low-power high-speed ultra-wideband (UWB) transmitter with a wireless transmission test platform. The system is specifically designed for low-power high-speed wireless implantable biosensors. The integrated transmitter consists of a compact pulse generator and a modulator. The circuit is fabricated in the 0.5-mum silicon-on-sapphire process and occupies 420 mum times 420 mum silicon area. The transmitter is capable of generating pulses with 1-ns width and the pulse rate can be controlled between 90 MHz and 270 MHz. We built a demonstration/testing system for the transmitter. The transmitter achieves a 14-Mb/s data rate. With 50% duty cycle data, the power consumption of the chip is between 10 mW and 21 mW when the transmission distance is from 3.2 to 4 m. The core circuit size is 70 mum times 130 mum.

  19. Dynamic Contrast-Enhanced CT Characterization of Xp11.2 Translocation/TFE3 Gene Fusions versus Papillary Renal Cell Carcinomas

    PubMed Central

    He, Jian; Zhou, Kefeng; Zhu, Bin; Zhang, Gutian; Li, Xiaogong; Guo, Hongqian; Gan, Weidong; Zhou, Zhengyang; Liu, Tian

    2015-01-01

    Purpose. To compare the differences of CT characteristics between renal cell carcinomas (RCCs) associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 RCCs) and papillary cell renal cell carcinomas (PRCCs). Methods. CT images and clinical records of 64 patients (25 Xp11.2 RCCs, 15 type 1 and 24 type 2 PRCCs) were analyzed and compared retrospectively. Results. Xp11.2 RCC more frequently affected young (30.7 ± 8.7 years) women (16/25, 64%) with gross hematuria (12/25, 48%), while PRCC more frequently involved middle-aged (54.8 ± 11.1 years) men (28/39, 71.8%) asymptomatically. Xp11.2 RCC tended to be heterogeneous density with some showing circular calcification. Lesion sizes of Xp11.2 RCC (5.4 ± 2.2 cm) and type 2 PRCC (5.7 ± 2.5 cm) were significantly larger than that of type 1 PRCC (3.8 ± 1.8 cm). Xp11.2 RCC contained more cystic components (22/25, 88%) than type 1 PRCC (all solid) and type 2 PRCC (9/24, 36.0%). Type 1 PRCC (13/15, 86.7%) and Xp11.2 RCC (21/25, 84.0%) showed more clear boundary than type 2 PRCC (12/24, 50.0%). Conclusion. CT features including diameter, boundary, attenuation, nature, and circular calcification of the tumor, combined with demographic information and symptoms, may be useful to differentiate Xp11.2 RCC from different subtypes of PRCC. PMID:26636097

  20. Xp11.2 translocation renal cell carcinoma with TFE3 gene fusion: A case report

    PubMed Central

    Pan, Xiang; Quan, Jing; Zhao, Liwen; Li, Wenhua; Wei, Benlin; Yang, Shangqi; Lai, Yongqing

    2018-01-01

    Xp11.2 translocation renal cell carcinoma (RCC) with transcription factor E3 (TFE3) gene fusion is a rare tumor, and the prognosis of this tumor is poorer compared with that of other subtypes of RCC. The patient presented herein was a 70-year-old man who presented with a solid mass sized ~8.2×6.1 cm in the right kidney and underwent radical right nephrectomy. Following pathological and immunohistochemical (IHC) examination and fluorescent in situ hybridization (FISH), the patient was diagnosed with Xp11.2 translocation RCC with TFE3 gene fusion. These tumors are more commonly encountered in children rather than in adults, and adult Xp11.2 translocation RCC is associated with a poorer prognosis compared with its pediatric counterpart. IHC assay and FISH are important diagnostic methods. However, there is currently no established effective treatment for Xp11.2 RCC. PMID:29399348

  1. Xp11.2 translocation renal cell carcinoma with TFE3 gene fusion: A case report.

    PubMed

    Pan, Xiang; Quan, Jing; Zhao, Liwen; Li, Wenhua; Wei, Benlin; Yang, Shangqi; Lai, Yongqing

    2018-01-01

    Xp11.2 translocation renal cell carcinoma (RCC) with transcription factor E3 (TFE3) gene fusion is a rare tumor, and the prognosis of this tumor is poorer compared with that of other subtypes of RCC. The patient presented herein was a 70-year-old man who presented with a solid mass sized ~8.2×6.1 cm in the right kidney and underwent radical right nephrectomy. Following pathological and immunohistochemical (IHC) examination and fluorescent in situ hybridization (FISH), the patient was diagnosed with Xp11.2 translocation RCC with TFE3 gene fusion. These tumors are more commonly encountered in children rather than in adults, and adult Xp11.2 translocation RCC is associated with a poorer prognosis compared with its pediatric counterpart. IHC assay and FISH are important diagnostic methods. However, there is currently no established effective treatment for Xp11.2 RCC.

  2. Simple method enabling pulse on command from high power, high frequency lasers

    NASA Astrophysics Data System (ADS)

    Baer, David J.; Marshall, Graham D.; Coutts, David W.; Mildren, Richard P.; Withford, Michael J.

    2006-09-01

    A method for addressing individual laser pulses in high repetition frequency systems using an intracavity optical chopper and novel electronic timing system is reported. This "pulse on command" capability is shown to enable free running and both subharmonic pulse rate and burst mode operation of a high power, high pulse frequency copper vapor laser while maintaining a fixed output pulse energy. We demonstrate that this technique can be used to improve feature finish when laser micromachining metal.

  3. Schools Facing the Expiration of Windows XP

    ERIC Educational Resources Information Center

    Cavanagh, Sean

    2013-01-01

    Microsoft's plans to end support for Windows XP, believed to be the dominant computer operating system in K-12 education, could pose big technological and financial challenges for districts nationwide--issues that many school systems have yet to confront. The giant software company has made it clear for years that it plans to stop supporting XP…

  4. A simple sub-nanosecond ultraviolet light pulse generator with high repetition rate and peak power.

    PubMed

    Binh, P H; Trong, V D; Renucci, P; Marie, X

    2013-08-01

    We present a simple ultraviolet sub-nanosecond pulse generator using commercial ultraviolet light-emitting diodes with peak emission wavelengths of 290 nm, 318 nm, 338 nm, and 405 nm. The generator is based on step recovery diode, short-circuited transmission line, and current-shaping circuit. The narrowest pulses achieved have 630 ps full width at half maximum at repetition rate of 80 MHz. Optical pulse power in the range of several hundreds of microwatts depends on the applied bias voltage. The bias voltage dependences of the output optical pulse width and peak power are analysed and discussed. Compared to commercial UV sub-nanosecond generators, the proposed generator can produce much higher pulse repetition rate and peak power.

  5. Xp11.2 translocation renal cell carcinoma with multiple bone metastases: A case report.

    PubMed

    Liu, Jiaju; Su, Zhengming; Li, Yifan; Chen, Duqun; Ni, Liangchao; Mao, Xiangming; Yang, Shangqi; Lai, Yongqing

    2016-03-01

    Xp11.2 translocation/transcription factor enhancer 3 (TFE3) fusion gene associated with renal cell carcinoma (Xp11.2 translocation RCC) is rare and occurs predominantly in children and adolescents. The current study reports the case of a 14-year-old male with Xp11.2 translocation RCC, who presented with chest pain that had persisted for 1 month. A solid neoplasm was located in the left kidney of the patient. Contrast-enhanced computed tomography revealed the presence of a solid mass in the kidney, with uneven enhancement. Destruction of multiple bones was also observed. The patient was treated with a radical nephrectomy. The pathological examination of the tumor revealed that the tumor cells contained an eosinophilic cytoplasm in the renal interstitial tissue. Immunohistochemistry revealed that the tumor cells expressed P504S, cluster of differentiation 10, pan-cytokeratin, vimentin and TFE3. In conclusion, Xp11.2 translocation RCC is a rare type of kidney cancer. Diagnosing this disease prior to surgery is challenging, and providing a definite diagnosis requires histopathological and immunohistochemical examination, while genetic analysis may also be required.

  6. Formation of short high-power laser radiation pulses in excimer mediums

    NASA Astrophysics Data System (ADS)

    Losev, V. F., Sr.; Ivanov, N. G.; Panchenko, Yu. N.

    2007-06-01

    Presently an excimer mediums continue are examined as one of variants for formation of powerful and over powerful pulses of laser radiation with duration from units of nanosecond up to tens femtosecond. The researches on such powerful installations as "NIKE" (USA) and << SUPER ASHURA >>, Japan) proceed in this direction. The main advantage of excimer mediums is the opportunity to work in a frequency mode, absence of restriction on the size of active area, high uniformity of a gas working medium, high efficiency (up to 10 %) and wide spectral range of laser radiation (KrF, XeCl ~ 2nm, XeF (C-A), Xe IICl ~ 50-100 nanometers). Research in area of high quality laser beams formation in excimer mediums and its amplification in high power amplifiers are carried out the long time in Institute of High Current Electronics SB RAS, Tomsk, Russia. The wide aperture XeCl laser system of MELS-4k is used for these investigations. Last time we take part in program on development of high power excimer laser system with a petawatt level of power. This system supposes the formation and amplification high quality laser beams with different pulse duration from units of nanosecond up to tens femtosecond. We research the possibility of laser beams formation in excimer mediums with ps-ns pulse duration having the low noise and divergence near to diffraction limit. In other hand, we are developing the wide aperture XeF(C-A) amplifier with optical pump on base electron accelerator. According to our estimations of the XeF(C-A) amplifier based on the converter of e-beam energy to the Xe II* fluorescence at 172 nm will allow to obtain up to 100 TW peak power in a 30 fs pulse.

  7. Modeling of high efficiency solar cells under laser pulse for power beaming applications

    NASA Technical Reports Server (NTRS)

    Jain, Raj K.; Landis, Geoffrey A.

    1994-01-01

    Solar cells have been used to convert sunlight to electrical energy for many years and also offer great potential for non-solar energy conversion applications. Their greatly improved performance under monochromatic light compared to sunlight, makes them suitable as photovoltaic (PV) receivers in laser power beaming applications. Laser beamed power to a PV array receiver could provide power to satellites, an orbital transfer vehicle, or a lunar base. Gallium arsenide (GaAs) and indium phosphide (InP) solar cells have calculated efficiencies of more than 50 percent under continuous illumination at the optimum wavelength. Currently high power free-electron lasers are being developed which operate in pulsed conditions. Understanding cell behavior under a laser pulse is important in the selection of the solar cell material and the laser. An experiment by NAsA lewis and JPL at the AVLIS laser facility in Livermore, CA presented experimental data on cell performance under pulsed laser illumination. Reference 5 contains an overview of technical issues concerning the use of solar cells for laser power conversion, written before the experiments were performed. As the experimental results showed, the actual effects of pulsed operation are more complicated. Reference 6 discusses simulations of the output of GaAs concentrator solar cells under pulsed laser illumination. The present paper continues this work, and compares the output of Si and GaAs solar cells.

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: EVALUATION OF THE XP-SWMM STORMWATER WASTEWATER MANAGEMENT MODEL, VERSION 8.2, 2000, FROM XP SOFTWARE, INC.

    EPA Science Inventory

    XP-SWMM is a commercial software package used throughout the United States and around the world for simulation of storm, sanitary and combined sewer systems. It was designed based on the EPA Storm Water Management Model (EPA SWMM), but has enhancements and additional algorithms f...

  9. 1-MHz high power femtosecond Yb-doped fiber chirped-pulse amplifier

    NASA Astrophysics Data System (ADS)

    Hu, Zhong-Qi; Yang, Pei-Long; Teng, Hao; Zhu, Jiang-Feng; Wei, Zhi-Yi

    2018-01-01

    A practical femtosecond polarization-maintaining Yb-doped fiber amplifier enabling 153 fs transform-limited pulse duration with 32 μJ pulse energy at 1 MHz repetition rate corresponding to a peak power of 0.21 GW is demonstrated. The laser system based on chirped-pulse amplification (CPA) technique is seeded by a dispersion managed, nonlinear polarization evolution (NPE) mode-locked oscillator with spectrum bandwidth of 31 nm at 1040 nm and amplified by three fiber pre-amplifying stages and a rod type fiber main amplifying stage. The laser works with beam quality of M2 of 1.3 and power stability of 0.63% (root mean square, RMS) over 24 hours will be stable sources for industrial micromachining, medical therapy and scientific research.

  10. First reported case of intrachromosomal cryptic inv dup del Xp in a boy with developmental retardation.

    PubMed

    Dupont, Celine; Lebbar, Aziza; Teinturier, Cecile; Baverel, Françoise; Viot, Geraldine; Le Tessier, Dominique; Le Bozec, Jerome; Cuisset, Laurence; Dupont, Jean-Michel

    2007-06-01

    We report here on a 6-year-old boy referred to the laboratory for karyotyping and SHOX microdeletion testing. The most significant clinical findings in this boy were small stature, Madelung deformity, facial dysmorphism, mild mental retardation and behavioral problems. R-, G- and RTBG-banding chromosome analysis showed a normal male karyotype. Fine molecular characterization, by FISH, of terminal Xp microdeletion revealed an associated partial duplication. Further refinement of the molecular analysis indicated an inverted duplication of the Xp22.31-Xp22.32 (13.7 Mb) region including the STS, VCX-A and KAL1 genes, associated with a terminal Xp deletion Xp22.33-Xpter (3.6 Mb) encompassing the SHOX and ARSE genes. Such rearrangements have been characterized for other chromosomal pairs, but this is the first reported male patient involving the short arm of the X chromosome. Molecular analysis of the maternal and patient's microsatellite markers showed interchromatid mispairing leading to non-allelic homologous recombination to be the most likely mechanism underlying this rearrangement. This case highlights the importance of clinically driven FISH investigations in order to uncover cryptic micro-rearrangements. Copyright (c) 2007 Wiley-Liss, Inc.

  11. Diagnosis of Xp11.2 Translocation Renal Cell Carcinomas in the Thai Patients.

    PubMed

    Junthaworn, Boontarika; Pradniwat, Kanapon; Hanamornroongruang, Suchanan

    2015-11-01

    Xp11.2 translocation renal cell carcinomas (TRCCs) are rare tumors recently accepted as a separated tumor type in 2004 WHO classification. To diagnose these tumors, histological recognition and confirmation of translocation are necessary. While the incidence of overall renal cell carcinomas (RCCs) is increased after the age of 40, Xp11.2 TRCCs are predominantly reported in young patients. The incidence of these tumors in Thailand has not been evaluated. To identify the frequency of Xp11.2 TRCCs, clinical presentation and follow-up information in 40 year-old or younger patients by using TFE3 immunostaining to confirm the translocation. All cases of 0- to 40-years-old patients diagnosed as RCCs from nephrectomy specimens between 2001 and 2011 at Siriraj Hospital were reviewed by one pathology resident and two pathologists. Immunohistochemical staining for TFE3 was performed on cases morphologically suspected for TRCC or showing unusual histology. Four cases consistent with Xp11.2 TRCC were identified by TFE3 immunostaining from all 31 cases (12.9%). Three cases were females and one was male. Two cases were at stage 4 and passed away several months after the operation. The other two patients were at stage 2. One patient is alive without recurrence for at least 36 months after surgery alone. The other died from underlying SLE. TFE3 immunostaining is a useful andpractical toolfor screening and diagnosis of Xp11.2 TRCCs, but staining results can be difficult to interpret. Thus, genetic analysis is still necessary especially when immunostaining shows problematic result. Fresh tumor tissue sampling in all young patients is recommended in case of further genetic studies needed.

  12. A new digital pulse power supply in heavy ion research facility in Lanzhou

    NASA Astrophysics Data System (ADS)

    Wang, Rongkun; Chen, Youxin; Huang, Yuzhen; Gao, Daqing; Zhou, Zhongzu; Yan, Huaihai; Zhao, Jiang; Shi, Chunfeng; Wu, Fengjun; Yan, Hongbin; Xia, Jiawen; Yuan, Youjin

    2013-11-01

    To meet the increasing requirements of the Heavy Ion Research Facility in Lanzhou-Cooler Storage Ring (HIRFL-CSR), a new digital pulse power supply, which employs multi-level converter, was designed. This power supply was applied with a multi H-bridge converters series-parallel connection topology. A new control model named digital power supply regulator system (DPSRS) was proposed, and a pulse power supply prototype based on DPSRS has been built and tested. The experimental results indicate that tracking error and ripple current meet the requirements of this design. The achievement of prototype provides a perfect model for HIRFL-CSR power supply system.

  13. ClpXP-Dependent RpoS Degradation Enables Full Activation of Type III Secretion System, Amylovoran Production, and Motility in Erwinia amylovora.

    PubMed

    Lee, Jae Hoon; Zhao, Youfu

    2017-11-01

    Erwinia amylovora, the causal agent of fire blight disease of apple and pear, employs intracellular proteases, including Lon and ClpXP, for posttranslational regulation of various cellular proteins. It has been shown that Lon plays a critical role in E. amylovora virulence by directly targeting type III secretion system (T3SS) proteins and the Rcs phosphorelay system. In this study, we genetically examined the role of ClpXP and its potential interaction with Lon in E. amylovora. Mutation in clpXP diminished the expression of the T3SS, reduced exopolysaccharide amylovoran production and motility, and resulted in delayed disease progress. Western blot analyses showed highly accumulated RpoS proteins in the clpXP mutant. Moreover, mutation of rpoS in the clpXP mutant background rescued the expression of the T3SS and amylovoran production, suggesting that ClpXP-dependent RpoS degradation positively affects virulence traits. Interestingly, lack of both ClpXP and Lon resulted in significantly reduced virulence but increased expression of the T3SS and amylovoran production. However, this phenomenon was independent of RpoS accumulation, suggesting that ClpXP and Lon are indispensable for full virulence in E. amylovora.

  14. Diagnosis of adults Xp11.2 translocation renal cell carcinoma by immunohistochemistry and FISH assays: clinicopathological data from ethnic Chinese population.

    PubMed

    Qu, Yuanyuan; Gu, Chengyuan; Wang, Hongkai; Chang, Kun; Yang, Xiaoqun; Zhou, Xiaoyan; Dai, Bo; Zhu, Yao; Shi, Guohai; Zhang, Hailiang; Ye, Dingwei

    2016-02-16

    This study aimed to assess the utility of transcription factor E3 (TFE3) break-apart fluorescence in situ hybridization (FISH) assay in diagnosis of Xp11.2 translocation renal cell carcinoma (Xp11.2 RCC) and to compare the clinicopathological features between adult Xp11.2 RCC and non-Xp11.2 RCC. 76 pathologically suspected Xp11.2 RCCs were recruited from our institution. Both TFE3 immunohistochemistry (IHC) and TFE3 FISH assay were performed for the entire cohort. The progression-free survival (PFS) and overall survival (OS) curves were estimated using the Kaplan-Meier method. FISH analysis confirmed 30 Xp11.2 RCCs, including 28 cases with positive TFE3 immunostaining and 2 cases with negative immunostaining. The false-positive and false-negative rates were 6.7% (2/30) and 4.3% (2/46), respectively, for TFE3 IHC compared with FISH assay. Xp11.2 RCC was significantly associated with higher pathological stage and Fuhrman nuclear grade compared with non-Xp11.2 RCC (P < 0.05). The median PFS and OS for TFE3 FISH-positive group were 13.0 months (95% CI, 8.4-17.6 months) and 50.0 months (95% CI, 27.6-72.4 months), respectively, while the median PFS and OS had not been reached for TFE3 FISH-negative group. In conclusion, TFE3 break-apart FISH assay is a highly useful and standard diagnostic method for Xp11.2 RCC. Adult Xp11.2 RCC is clinically aggressive and often presents at advanced stage with poor prognosis.

  15. Sirt1 suppresses RNA synthesis after UV irradiation in combined xeroderma pigmentosum group D/Cockayne syndrome (XP-D/CS) cells.

    PubMed

    Vélez-Cruz, Renier; Zadorin, Anton S; Coin, Frédéric; Egly, Jean-Marc

    2013-01-15

    Specific mutations in the XPD subunit of transcription factor IIH result in combined xeroderma pigmentosum (XP)/Cockayne syndrome (CS), a severe DNA repair disorder characterized at the cellular level by a transcriptional arrest following UV irradiation. This transcriptional arrest has always been thought to be the result of faulty transcription-coupled repair. In the present study, we showed that, following UV irradiation, XP-D/CS cells displayed a gross transcriptional dysregulation compared with "pure" XP-D cells or WT cells. Furthermore, global RNA-sequencing analysis showed that XP-D/CS cells repressed the majority of genes after UV, whereas pure XP-D cells did not. By using housekeeping genes as a model, we demonstrated that XP-D/CS cells were unable to reassemble these gene promoters and thus to restart transcription after UV irradiation. Furthermore, we found that the repression of these promoters in XP-D/CS cells was not a simple consequence of deficient repair but rather an active heterochromatinization process mediated by the histone deacetylase Sirt1. Indeed, RNA-sequencing analysis showed that inhibition of and/or silencing of Sirt1 changed the chromatin environment at these promoters and restored the transcription of a large portion of the repressed genes in XP-D/CS cells after UV irradiation. Our work demonstrates that a significant part of the transcriptional arrest displayed by XP-D/CS cells arises as a result of an active repression process and not simply as a result of a DNA repair deficiency. This dysregulation of Sirt1 function that results in transcriptional repression may be the cause of various severe clinical features in patients with XP-D/CS that cannot be explained by a DNA repair defect.

  16. Pseudocapsule of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion: a clue for tumor enucleation?

    PubMed

    Cheng, Xiangming; He, Jian; Gan, Weidong; Fan, Xiangshan; Yang, Jun; Zhu, Bin; Guo, Hongqian

    2015-01-01

    To evaluate the feasibility and efficacy of tumor enucleation (TE) for patients with small renal cell carcinoma (RCC) associated with Xp11.2 translocation/TFE3 gene fusion (Xp11.2 RCC) by analyzing the pseudocapsule characteristics of Xp11.2 RCCs comparing with that of clear cell renal cell carcinoma (ccRCC). From June 2007 to February 2014, 22 patients with Xp11.2 RCC who were diagnosed by fluorescence in-situ hybridization polyclonal (FISH) assay and 32 patients with ccRCC treated in our institution were comparatively studied. 12 patients with ccRCC underwent radical nephrectomy (RN) and 20 received TE. Among 22 patients with Xp11.2 RCC, 19 were treated by RN and 3 by TE (1 by radiofrequency ablation assisted TE). Pseudocapsule and other clinicopathological characteristics of the two subtypes of RCC were compared. Survival of patients treated with different surgical methods was evaluated and compared. Pseudocapsule incidence of Xp11.2 RCC (14/22, 63.6%) was lower than that of ccRCC (32/32, 100%, P<0.001). However, pseudocapsule integrity rate of Xp11.2 RCC (10/14, 71.4%) was comparable with that of ccRCC (23/32, 71.9%, P=1.000). The 5-year overall survival of patients with ccRCC treated with RN and TE was 86% and 81%, respectively (P=0.845). Three patients with small Xp11.2 RCC performed well after TE. Over half Xp11.2 RCC had pseudocapsules, whose integrity rate was comparable to that of ccRCC. Treatment effectives of TE and RN were comparable in ccRCC. A preliminary attempt to treat small Xp11.2 RCC with intact pseudocapsule by using TE produced a favorable treatment outcome.

  17. The multislice CT findings of renal carcinoma associated with XP11.2 translocation/TFE gene fusion and collecting duct carcinoma.

    PubMed

    Zhu, Qing-Qiang; Wang, Zhong-Qiu; Zhu, Wen-Rong; Chen, Wen-Xin; Wu, Jing-Tao

    2013-04-01

    Renal cell carcinoma associated with Xp11.2 translocation and TFE gene fusion (Xp11.2/TFE RCC), and collecting duct carcinoma (CDC) are uncommon subtypes of renal cell carcinomas. To investigate the multislice CT (MSCT) characteristics of these two tumor types. Nine patients with Xp11.2/TFE RCC and 10 patients with CDC were studied retrospectively. MSCT was undertaken to investigate differences in tumor characteristics and enhancement patterns. All patients had single tumors centered in the renal medulla. Two patients with each tumor type had lymph node involvement and there was a single case of hepatic metastasis (Xp11.2/TFE RCC). The mean tumor diameter of Xp11.2/TFE RCC tumors was significantly larger than for CDC tumors. Two patients with Xp11.2/TFE RCC had cystic components as did eight patients with CDC (P < 0.05). Calcifications were present in six patients, each with CDC. Clear tumor boundaries were visible in two patients with CDC and in nine with Xp11.2/TFE RCC (P < 0.05). The density of Xp11.2/TFE RCC tumors was greater than that of CDC tumors, normal renal cortex, or medulla on unenhanced CT. Enhancement was higher with Xp11.2/TFE RCC than with CDC tumors during all phases. Xp11.2/TFE RCC enhancement was higher than in the renal medulla during cortical and medullary phase but lower than in normal renal medulla during the delayed phase. CDC tumor enhancement was lower than that for normal renal medulla during all enhanced phases. Both tumor types originated from the renal medulla. Distinguishing features included density on unenhanced CT, enhancement patterns, and capsule signs. Identifying these differences may aid diagnosis.

  18. Pseudocapsule of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion: a clue for tumor enucleation?

    PubMed Central

    Cheng, Xiangming; He, Jian; Gan, Weidong; Fan, Xiangshan; Yang, Jun; Zhu, Bin; Guo, Hongqian

    2015-01-01

    Objectives: To evaluate the feasibility and efficacy of tumor enucleation (TE) for patients with small renal cell carcinoma (RCC) associated with Xp11.2 translocation/TFE3 gene fusion (Xp11.2 RCC) by analyzing the pseudocapsule characteristics of Xp11.2 RCCs comparing with that of clear cell renal cell carcinoma (ccRCC). Methods: From June 2007 to February 2014, 22 patients with Xp11.2 RCC who were diagnosed by fluorescence in-situ hybridization polyclonal (FISH) assay and 32 patients with ccRCC treated in our institution were comparatively studied. 12 patients with ccRCC underwent radical nephrectomy (RN) and 20 received TE. Among 22 patients with Xp11.2 RCC, 19 were treated by RN and 3 by TE (1 by radiofrequency ablation assisted TE). Pseudocapsule and other clinicopathological characteristics of the two subtypes of RCC were compared. Survival of patients treated with different surgical methods was evaluated and compared. Results: Pseudocapsule incidence of Xp11.2 RCC (14/22, 63.6%) was lower than that of ccRCC (32/32, 100%, P<0.001). However, pseudocapsule integrity rate of Xp11.2 RCC (10/14, 71.4%) was comparable with that of ccRCC (23/32, 71.9%, P=1.000). The 5-year overall survival of patients with ccRCC treated with RN and TE was 86% and 81%, respectively (P=0.845). Three patients with small Xp11.2 RCC performed well after TE. Conclusions: Over half Xp11.2 RCC had pseudocapsules, whose integrity rate was comparable to that of ccRCC. Treatment effectives of TE and RN were comparable in ccRCC. A preliminary attempt to treat small Xp11.2 RCC with intact pseudocapsule by using TE produced a favorable treatment outcome. PMID:26191243

  19. Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hacke, Peter L; Rodriguez, Miguel; Kempe, Michael D

    An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will be required on additional module level power electronic (MLPE) devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.

  20. Design and experiment of a directional coupler for X-band long pulse high power microwaves.

    PubMed

    Bai, Zhen; Li, Guolin; Zhang, Jun; Jin, Zhenxing

    2013-03-01

    Higher power and longer pulse are the trend of the development of high power microwave (HPM), and then some problems emerge in measuring the power of HPM because rf breakdown is easier to occur under the circumstance of high power (the level of gigawatt) and long pulse (about 100 ns). In order to measure the power of the dominant TM₀₁ mode of an X-band long pulse overmoded HPM source, a directional coupler with stable coupling coefficient, high directivity, and high power handling capacity in wide band is investigated numerically and experimentally. At the central frequency 9.4 GHz, the simulation results show that the coupling coefficient is -59.6 dB with the directivity of 35 dB and the power handling capacity of 2 GW. The coupling coefficient is calibrated to be accordant with the simulation results. The high power tests are performed on an X-band long pulse HPM source, whose output mode is mainly TM₀₁ mode, and the results show that the measured power and waveform of the directional coupler have a good consistency with the far-field measuring results.

  1. Application of lasers and pulsed power to coating removal

    NASA Astrophysics Data System (ADS)

    Young, Chris M.; Moeny, William M.; Curry, Randy D.; McDonald, Ken; Bosma, John T.

    1995-03-01

    Lasers and other pulsed power systems are uniquely suited for removal of coatings from a wide variety of substrates. Coatings which can be removed by these systems include paint, adhesives, epoxies, dips, rust, scale, and bird droppings. Suitable substrates include wood, metal, cloth, stone, ceramic, plastics, and even skin. These systems have the advantage over chemical stripping or mechanical abrasion in that the substrate is left virtually unharmed and in many cases the residue is reduced to a form that is more easily disposed of without toxic byproducts or expensive refurbishment. Furthermore, laser and other pulsed power based systems can be operated using only local containment without the need for special operator protective gear or complete enclosure of the substrate structure. Additional advantages are gained in these systems because they typically combine multiple removal mechanisms for greater effectiveness. For example, pulsed lasers create rapid heating of the coating. This rapid heating can result in chemical breakdown of the coating, thermomechanical stress induced dislocation, shock wave agitation, and physical ablation. This paper presents some of the latest research findings on coating removal using these systems. A comparative survey of the system technology, effectiveness, cost, and application is presented. Also presented is a survey of the commercial potential for the systems. Systems which are presented include lasers (CW, pulsed, Infrared, UV, etc.), flashlamps, electro-cathodic debonders, electron beams, and glow discharges.

  2. Design of pulsed guiding magnetic field for high power microwave generators.

    PubMed

    Ju, J-C; Zhang, H; Zhang, J; Shu, T; Zhong, H-H

    2014-09-01

    In this paper, we present a comprehensive study on designing solenoid together with the corresponding power supply system to excite pulsed magnetic field required for high power microwave generators. Particularly, a solenoid is designed and the excited magnetic field is applied to a Ku-band overmoded Cerenkov generator. It is found in experiment that the electron beam is properly guided by the magnetic field and a 1.1 GW high power microwave is achieved at a central frequency of 13.76 GHz. Pulsed solenoid system has the advantages of compactness and low energy consumption, which are of great interest for repetitive operation. The reported studies and results can be generalized to other applications which require magnetic fields.

  3. Xp11.2 translocation renal cell carcinoma with multiple bone metastases: A case report

    PubMed Central

    LIU, JIAJU; SU, ZHENGMING; LI, YIFAN; CHEN, DUQUN; NI, LIANGCHAO; MAO, XIANGMING; YANG, SHANGQI; LAI, YONGQING

    2016-01-01

    Xp11.2 translocation/transcription factor enhancer 3 (TFE3) fusion gene associated with renal cell carcinoma (Xp11.2 translocation RCC) is rare and occurs predominantly in children and adolescents. The current study reports the case of a 14-year-old male with Xp11.2 translocation RCC, who presented with chest pain that had persisted for 1 month. A solid neoplasm was located in the left kidney of the patient. Contrast-enhanced computed tomography revealed the presence of a solid mass in the kidney, with uneven enhancement. Destruction of multiple bones was also observed. The patient was treated with a radical nephrectomy. The pathological examination of the tumor revealed that the tumor cells contained an eosinophilic cytoplasm in the renal interstitial tissue. Immunohistochemistry revealed that the tumor cells expressed P504S, cluster of differentiation 10, pan-cytokeratin, vimentin and TFE3. In conclusion, Xp11.2 translocation RCC is a rare type of kidney cancer. Diagnosing this disease prior to surgery is challenging, and providing a definite diagnosis requires histopathological and immunohistochemical examination, while genetic analysis may also be required. PMID:26998154

  4. Pulse Power--A Heart Physiology Program for Children.

    ERIC Educational Resources Information Center

    Hinson, Curt

    1994-01-01

    Primary grade students at a Delaware elementary school currently participate in the Pulse Power heart physiology program. Students receive mastery instruction and use heart monitors to exercise performance throughout the 6-phase program. Data from homework and from the heart monitors identify student progress, knowledge, and cardiovascular…

  5. Optimized power simulation of AlGaN/GaN HEMT for continuous wave and pulse applications

    NASA Astrophysics Data System (ADS)

    Tiwat, Pongthavornkamol; Lei, Pang; Xinhua, Wang; Sen, Huang; Guoguo, Liu; Tingting, Yuan; Xinyu, Liu

    2015-07-01

    An optimized modeling method of 8 × 100 μm AlGaN/GaN-based high electron mobility transistor (HEMT) for accurate continuous wave (CW) and pulsed power simulations is proposed. Since the self-heating effect can occur during the continuous operation, the power gain from the continuous operation significantly decreases when compared to a pulsed power operation. This paper extracts power performances of different device models from different quiescent biases of pulsed current-voltage (I-V) measurements and compared them in order to determine the most suitable device model for CW and pulse RF microwave power amplifier design. The simulated output power and gain results of the models at Vgs = -3.5 V, Vds = 30 V with a frequency of 9.6 GHz are presented. Project supported by the National Natural Science Foundation of China (No. 61204086).

  6. PD-L1 expression in Xp11.2 translocation renal cell carcinoma: Indicator of tumor aggressiveness.

    PubMed

    Chang, Kun; Qu, Yuanyuan; Dai, Bo; Zhao, Jian-Yuan; Gan, Hualei; Shi, Guohai; Zhu, Yiping; Shen, Yijun; Zhu, Yao; Zhang, Hailiang; Ye, Dingwei

    2017-05-18

    Programmed death ligand-1 (PD-L1), a promising antitumor target, has proven clinical value against many malignancies. However, the PD-L1 content of Xp11.2 translocation renal cell carcinoma (Xp11.2 RCC) and its correlation with clinical outcomes remain unclear. This study aimed to investigate PD-L1 expression in Xp11.2 RCC and to assess its prognostic value. Formalin-fixed paraffin-embedded specimens from 36 adult patients that were histologically confirmed (by fluorescence in situ hybridization) were subjected to immunohistochemical analysis. Of the 36 Xp11.2 RCC patients, 9 (25.0%) had tumors with positive PD-L1 expression and 27 (75.0%) had tumors with negative PD-L1 expression. Positive PD-L1 expression correlated with advanced tumor stage (P = 0.001), regional lymph node metastasis (P < 0.001), and distant metastasis (P < 0.001). A multivariate analysis identified positive PD-L1 expression was an independent adverse prognostic factor for both progression free survival (hazard ratio: 3.7, P = 0.018) and overall survival (hazard ratio: 4.5, P = 0.034). The median PFS and OS for the whole cohort were 13.0 months (95% confidence interval [CI], 9.4-16.6 months) and 36.0 months (95% CI, 23.9-48.1 months), respectively. Our findings suggest that positive PD-L1 expression is indicative of worse clinical outcome in Xp11.2 RCC. Further studies are needed to explore the potential efficacy of targeting PD-L1 in Xp11.2 RCC.

  7. Diagnosis of adults Xp11.2 translocation renal cell carcinoma by immunohistochemistry and FISH assays: clinicopathological data from ethnic Chinese population

    PubMed Central

    Qu, Yuanyuan; Gu, Chengyuan; Wang, Hongkai; Chang, Kun; Yang, Xiaoqun; Zhou, Xiaoyan; Dai, Bo; Zhu, Yao; Shi, Guohai; Zhang, Hailiang; Ye, Dingwei

    2016-01-01

    This study aimed to assess the utility of transcription factor E3 (TFE3) break-apart fluorescence in situ hybridization (FISH) assay in diagnosis of Xp11.2 translocation renal cell carcinoma (Xp11.2 RCC) and to compare the clinicopathological features between adult Xp11.2 RCC and non-Xp11.2 RCC. 76 pathologically suspected Xp11.2 RCCs were recruited from our institution. Both TFE3 immunohistochemistry (IHC) and TFE3 FISH assay were performed for the entire cohort. The progression-free survival (PFS) and overall survival (OS) curves were estimated using the Kaplan-Meier method. FISH analysis confirmed 30 Xp11.2 RCCs, including 28 cases with positive TFE3 immunostaining and 2 cases with negative immunostaining. The false-positive and false-negative rates were 6.7% (2/30) and 4.3% (2/46), respectively, for TFE3 IHC compared with FISH assay. Xp11.2 RCC was significantly associated with higher pathological stage and Fuhrman nuclear grade compared with non-Xp11.2 RCC (P < 0.05). The median PFS and OS for TFE3 FISH-positive group were 13.0 months (95% CI, 8.4–17.6 months) and 50.0 months (95% CI, 27.6–72.4 months), respectively, while the median PFS and OS had not been reached for TFE3 FISH-negative group. In conclusion, TFE3 break-apart FISH assay is a highly useful and standard diagnostic method for Xp11.2 RCC. Adult Xp11.2 RCC is clinically aggressive and often presents at advanced stage with poor prognosis. PMID:26880493

  8. High power high repetition rate VCSEL array side-pumped pulsed blue laser

    NASA Astrophysics Data System (ADS)

    van Leeuwen, Robert; Zhao, Pu; Chen, Tong; Xu, Bing; Watkins, Laurence; Seurin, Jean-Francois; Xu, Guoyang; Miglo, Alexander; Wang, Qing; Ghosh, Chuni

    2013-03-01

    High power, kW-class, 808 nm pump modules based on the vertical-cavity surface-emitting laser (VCSEL) technology were developed for side-pumping of solid-state lasers. Two 1.2 kW VCSEL pump modules were implemented in a dual side-pumped Q-switched Nd:YAG laser operating at 946 nm. The laser output was frequency doubled in a BBO crystal to produce pulsed blue light. With 125 μs pump pulses at a 300 Hz repetition rate 6.1 W QCW 946 nm laser power was produced. The laser power was limited by thermal lensing in the Nd:YAG rod.

  9. Conductive graphene as passive saturable absorber with high instantaneous peak power and pulse energy in Q-switched regime

    NASA Astrophysics Data System (ADS)

    Zuikafly, Siti Nur Fatin; Khalifa, Ali; Ahmad, Fauzan; Shafie, Suhaidi; Harun, SulaimanWadi

    2018-06-01

    The Q-switched pulse regime is demonstrated by integrating conductive graphene as passive saturable absorber producing relatively high instantaneous peak power and pulse energy. The fabricated conductive graphene is investigated using Raman spectroscopy. The single wavelength Q-switching operates at 1558.28 nm at maximum input pump power of 151.47 mW. As the pump power is increased from threshold power of 51.6 mW to 151.47 mW, the pulse train repetition rate increases proportionally from 47.94 kHz to 67.8 kHz while the pulse width is reduced from 9.58 μs to 6.02 μs. The generated stable pulse produced maximum peak power and pulse energy of 32 mW and 206 nJ, respectively. The first beat node of the measured signal-to-noise ratio is about 62 dB indicating high pulse stability.

  10. High-Average-Power Diffraction Pulse-Compression Gratings Enabling Next-Generation Ultrafast Laser Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alessi, D.

    Pulse compressors for ultrafast lasers have been identified as a technology gap in the push towards high peak power systems with high average powers for industrial and scientific applications. Gratings for ultrashort (sub-150fs) pulse compressors are metallic and can absorb a significant percentage of laser energy resulting in up to 40% loss as well as thermal issues which degrade on-target performance. We have developed a next generation gold grating technology which we have scaled to the petawatt-size. This resulted in improvements in efficiency, uniformity and processing as compared to previous substrate etched gratings for high average power. This new designmore » has a deposited dielectric material for the grating ridge rather than etching directly into the glass substrate. It has been observed that average powers as low as 1W in a compressor can cause distortions in the on-target beam. We have developed and tested a method of actively cooling diffraction gratings which, in the case of gold gratings, can support a petawatt peak power laser with up to 600W average power. We demonstrated thermo-mechanical modeling of a grating in its use environment and benchmarked with experimental measurement. Multilayer dielectric (MLD) gratings are not yet used for these high peak power, ultrashort pulse durations due to their design challenges. We have designed and fabricated broad bandwidth, low dispersion MLD gratings suitable for delivering 30 fs pulses at high average power. This new grating design requires the use of a novel Out Of Plane (OOP) compressor, which we have modeled, designed, built and tested. This prototype compressor yielded a transmission of 90% for a pulse with 45 nm bandwidth, and free of spatial and angular chirp. In order to evaluate gratings and compressors built in this project we have commissioned a joule-class ultrafast Ti:Sapphire laser system. Combining the grating cooling and MLD technologies developed here could enable petawatt laser

  11. Influence of the cubic spectral phase of high-power laser pulses on their self-phase modulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ginzburg, V N; Kochetkov, A A; Yakovlev, I V

    2016-02-28

    Spectral broadening of high-power transform-limited laser pulses under self-phase modulation in a medium with cubic nonlinearity is widely used to reduce pulse duration and to increase its power. It is shown that the cubic spectral phase of the initial pulse leads to a qualitatively different broadening of its spectrum: the spectrum has narrow peaks and broadening decreases. However, the use of chirped mirrors allows such pulses to be as effectively compressed as transform-limited pulses. (nonlinear optical phenomena)

  12. Short stature in a mother and daughter with terminal deletion of Xp22.3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwinger, E.; Kirschstein, M.; Konermann, T.

    1996-05-03

    Short stature in females is often caused by homozygosity for the terminal portion of Xp due to monosomy X or a deletion. We report on a mother and daughter with short stature as sole phenotypic abnormality and deletion of bands Xp22.32-p22.33 demonstrated by classic and molecular cytogenetic analysis. In both individuals, the deleted X chromosome was late replicating. Molecular analysis suggested that the deletion is terminal and the breakpoint was localized between the STS and DXS7470 loci in Xp22.32. Chromosome analysis is often done on females with short stature to exclude Ullrich-Turner syndrome. Small deletions, terminal or interstitial, are easilymore » missed by conventional cytogenetic investigation; thus molecular analyses are useful to detect those cases. 8 refs., 3 figs.« less

  13. Narrow linewidth picosecond UV pulsed laser with mega-watt peak power.

    PubMed

    Huang, Chunning; Deibele, Craig; Liu, Yun

    2013-04-08

    We demonstrate a master oscillator power amplifier (MOPA) burst mode laser system that generates 66 ps/402.5 MHz pulses with mega-watt peak power at 355 nm. The seed laser consists of a single frequency fiber laser (linewidth < 5 KHz), a high bandwidth electro-optic modulator (EOM), a picosecond pulse generator, and a fiber based preamplifier. A very high extinction ratio (45 dB) has been achieved by using an adaptive bias control of the EOM. The multi-stage Nd:YAG amplifier system allows a uniformly temporal shaping of the macropulse with a tunable pulse duration. The light output from the amplifier is converted to 355 nm, and over 1 MW peak power is obtained when the laser is operating in a 5-μs/10-Hz macropulse mode. The laser output has a transform-limited spectrum with a very narrow linewidth of individual longitudinal modes. The immediate application of the laser system is the laser-assisted hydrogen ion beam stripping for the Spallation Neutron Source (SNS).

  14. Nance-Horan syndrome: linkage analysis in 4 families refines localization in Xp22.31-p22.13 region.

    PubMed

    Toutain, A; Ronce, N; Dessay, B; Robb, L; Francannet, C; Le Merrer, M; Briard, M L; Kaplan, J; Moraine, C

    1997-02-01

    Nance-Horan syndrome (NHS) is an X-linked disease characterized by severe congenital cataract with microcornea, distinctive dental findings, evocative facial features and mental impairment in some cases. Previous linkage studies have placed the NHS gene in a large region from DXS143 (Xp22.31) to DXS451 (Xp22.13). To refine this localization further, we have performed linkage analysis in four families. As the maximum expected Lod score is reached in each family for several markers in the Xp22.31-p22.13 region and linkage to the rest of the X chromosome can be excluded, our study shows that NHS is a genetically homogeneous condition. An overall maximum two-point Lod score of 9.36 (theta = 0.00) is obtained with two closely linked markers taken together. DXS207 and DXS1053 in Xp22.2. Recombinant haplotypes indicate that the NHS gene lies between DXS85 and DXS1226. Multipoint analysis yield a maximum Lod score of 9.45 with the support interval spanning a 15-cM region that includes DXS16 and DXS1229/365. The deletion map of the Xp22.3-Xp21.3 region suggests that the phenotypic variability of NHS is not related to gross rearrangement of sequences of varying size but rather to allelic mutations in a single gene, presumably located proximal to DXS16 and distal to DXS1226. Comparison with the map position of the mouse Xcat mutation supports the location of the NHS gene between the GRPR and PDHA1 genes in Xp22.2.

  15. Laser-Material Interaction of Powerful Ultrashort Laser Pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Komashko, A

    2003-01-06

    Laser-material interaction of powerful (up to a terawatt) ultrashort (several picoseconds or shorter) laser pulses and laser-induced effects were investigated theoretically in this dissertation. Since the ultrashort laser pulse (USLP) duration time is much smaller than the characteristic time of the hydrodynamic expansion and thermal diffusion, the interaction occurs at a solid-like material density with most of the light energy absorbed in a thin surface layer. Powerful USLP creates hot, high-pressure plasma, which is quickly ejected without significant energy diffusion into the bulk of the material, Thus collateral damage is reduced. These and other features make USLPs attractive for amore » variety of applications. The purpose of this dissertation was development of the physical models and numerical tools for improvement of our understanding of the process and as an aid in optimization of the USLP applications. The study is concentrated on two types of materials - simple metals (materials like aluminum or copper) and wide-bandgap dielectrics (fused silica, water). First, key physical phenomena of the ultrashort light interaction with metals and the models needed to describe it are presented. Then, employing one-dimensional plasma hydrodynamics code enhanced with models for laser energy deposition and material properties at low and moderate temperatures, light absorption was self-consistently simulated as a function of laser wavelength, pulse energy and length, angle of incidence and polarization. Next, material response on time scales much longer than the pulse duration was studied using the hydrocode and analytical models. These studies include examination of evolution of the pressure pulses, effects of the shock waves, material ablation and removal and three-dimensional dynamics of the ablation plume. Investigation of the interaction with wide-bandgap dielectrics was stimulated by the experimental studies of the USLP surface ablation of water (water is a

  16. Influence of dispersion stretching of ultrashort UV laser pulse on the critical power for self-focusing

    NASA Astrophysics Data System (ADS)

    Ionin, A. A.; Mokrousova, D. V.; Piterimov, D. A.; Seleznev, L. V.; Sinitsyn, D. V.; Sunchugasheva, E. S.

    2018-04-01

    The critical power for self-focusing in air for ultrashort ultraviolet laser pulses, stretched due to dispersion from 90 to 730 fs, was experimentally measured. It was shown that the pulse duration enhancement due to its propagation in condensed media leads to an almost linear decrease in the critical power for self-focusing. It was also observed that when the pulse peak power exceeds the critical one, the maximum of linear plasma distribution along the ultraviolet laser filament does not shift in the direction opposite to the laser pulse propagation, as observed for infrared laser filaments, but remains at the geometrical focus.

  17. Melanotic Xp11 translocation renal cancer: report of a case with a unique intratumoral sarcoid-like reaction.

    PubMed

    Ritterhouse, Lauren L; Cykowski, Matthew D; Hassell, Lewis A; Slobodov, Gennady; Bane, Barbara L

    2014-04-15

    Melanotic Xp11 translocation renal cancer is a rare tumor belonging to the family of microphthalmia-associated transcription factor (MiTF)/transcription factor E (TFE) neoplasms. This tumor family also includes alveolar soft part sarcoma, perivascular epithelioid cell neoplasms, Xp11 translocation renal cell carcinoma, and melanoma. To date, six confirmed melanotic Xp11 translocation cancers (five renal, one ovarian) have been reported in the literature. Here, we report the clinical, histologic, immunohistochemical, and molecular features of a unique melanotic Xp11 translocation renal cancer arising in a 34-year-old African-American female. Histologically, the tumor was composed of epithelioid tumor cells arranged in a nested pattern. The cells had clear to eosinophilic granular cytoplasm, vesicular nuclear chromatin, and prominent nucleoli. Multifocal intracytoplasmic deposits of granular brown melanin pigment were identified and confirmed by Fontana-Masson stain. An unusual histologic feature, not previously reported in melanotic Xp11 translocation renal cancer, was a sarcoid-like granulomatous reaction consisting of tight epithelioid granulomas with lymphocytic cuffing, numerous giant cells, and calcifications. Nuclear transcription factor E3 expression was identified by immunohistochemistry and TFE3 rearrangement was confirmed by fluorescence in situ hybridization. Additional immunohistochemical findings included immunoreactivity for HMB45, cathepsin K, and progesterone receptor; negative staining was seen with actin, desmin, cytokeratins, epithelial membrane antigen, CD10, vimentin, and PAX-8. The patient is currently free of disease, two years following initial clinicoradiologic presentation and twenty-two months following partial nephrectomy without additional therapy. This report further expands the spectrum of morphologic and clinical findings previously described in melanotic Xp11 translocation renal cancer, a distinctive tumor showing overlapping

  18. Renal cell carcinoma associated with Xp11.2 translocation/TFE gene fusion: imaging findings in 21 patients.

    PubMed

    Chen, Xiao; Zhu, Qingqiang; Li, Baoxin; Cui, Wenjing; Zhou, Hao; Duan, Na; Liu, Yongkang; Kundra, Vikas; Wang, Zhongqiu

    2017-02-01

    To characterize imaging features of renal cell carcinoma (RCC) associated with Xp11.2 translocation/TFE gene fusion. Twenty-one patients with Xp11.2/TFE RCC were retrospectively evaluated. Tumour location, size, density, cystic or solid appearance, calcification, capsule sign, enhancement pattern and metastases were assessed. Fourteen women and seven men were identified with 12 being 25 years old or younger. Tumours were solitary and cystic-solid (76.2 %) masses with a capsule (76.2 %); 90.5 % were located in the medulla. Calcifications and lymph node metastases were each observed in 24 %. On unenhanced CT, tumour attenuation was greater than in normal renal parenchyma (85.7 %). Tumour enhancement was less than in normal renal cortex on all enhanced phases, greater than in normal renal medulla on cortical and medullary phases, but less than in normal renal medulla on delayed phase. On MR, the tumours were isointense on T1WI, heterogeneously hypointense on T2WI and slightly hyperintense on diffusion-weighted imaging. Xp11.2/TFE RCC usually occurs in young women. It is a cystic-solid, hyperdense mass with a capsule. It arises from the renal medulla with enhancement less than in the cortex but greater than in the medulla in all phases except the delayed phase, when it is lower than in the medulla. • Xp11.2/TFE RCC was more prevalent in young women. • On unenhanced CT, Xp11.2/TFE RCC attenuation was greater than in renal parenchyma. • Xp111/2TFE RCC arises primarily from the renal medulla. • Xp11.2/TFE RCC enhancement was less than in the cortex on all phases. • Enhancement was greater than in the medulla in arterial and corticomedullary phase.

  19. Cu3-xP Nanocrystals as a Material Platform for Near-Infrared Plasmonics and Cation Exchange Reactions

    PubMed Central

    2015-01-01

    Synthesis approaches to colloidal Cu3P nanocrystals (NCs) have been recently developed, and their optical absorption features in the near-infrared (NIR) have been interpreted as arising from a localized surface plasmon resonance (LSPR). Our pump–probe measurements on platelet-shaped Cu3-xP NCs corroborate the plasmonic character of this absorption. In accordance with studies on crystal structure analysis of Cu3P dating back to the 1970s, our density functional calculations indicate that this material is substoichiometric in copper, since the energy of formation of Cu vacancies in certain crystallographic sites is negative, that is, they are thermodynamically favored. Also, thermoelectric measurements point to a p-type behavior of the majority carriers from films of Cu3-xP NCs. It is likely that both the LSPR and the p-type character of our Cu3-xP NCs arise from the presence of a large number of Cu vacancies in such NCs. Motivated by the presence of Cu vacancies that facilitate the ion diffusion, we have additionally exploited Cu3-xP NCs as a starting material on which to probe cation exchange reactions. We demonstrate here that Cu3-xP NCs can be easily cation-exchanged to hexagonal wurtzite InP NCs, with preservation of the anion framework (the anion framework in Cu3-xP is very close to that of wurtzite InP). Intermediate steps in this reaction are represented by Cu3-xP/InP heterostructures, as a consequence of the fact that the exchange between Cu+ and In3+ ions starts from the peripheral corners of each NC and gradually evolves toward the center. The feasibility of this transformation makes Cu3-xP NCs an interesting material platform from which to access other metal phosphides by cation exchange. PMID:25960605

  20. Frequency up-conversion of a high-power microwave pulse propagating in a self-generated plasma

    NASA Technical Reports Server (NTRS)

    Kuo, S. P.; Ren, A.

    1992-01-01

    In the study of the propagation of a high-power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. A frequency autoconversion process that can lead to reflectionless propagation of powerful electromagnetic pulses in self-generated plasmas is studied. The theory shows that, under the proper condition, the carrier frequency omega of the pulse shifts upward during the growth of local plasma frequency omega(pe). Thus, the self-generated plasma remains underdense to the pulse. A chamber experiment to demonstrate the frequency autoconversion during the pulse propagation through the self-generated plasma is conducted. The detected frequency shift is compared with the theoretical result calculated by using the measured electron density distribution along the propagation path of the pulse. Good agreement is obtained.

  1. Postoperative recurrence of adult renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion.

    PubMed

    Wang, Zhen; Liu, Ning; Gan, Weidong; Li, Xiaogong; Zhang, Gutian; Li, Dongmei; Guo, Hongqian

    2017-08-01

    Objective To analyze the postoperative recurrence of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion (Xp11.2 tRCC). Methods This retrospective study was approved by the institutional review board and performed in accordance with the ethical standards established by the institution. Demographic, clinical, pathological, and follow-up data were compiled for the study cohort. Results During a mean follow-up of 41.3 months (range, 3-104 months), 8 of 34 patients with Xp11.2 tRCC were confirmed to have recurrence. Three of these patients died with poor outcomes due to a vena cava tumor embolus, and one died of distant metastasis 48 months after the initial nephrectomy during which lymph node metastasis was found. Three patients survived after cytoreduction surgery. One patient was diagnosed with lung metastasis 11 months postoperatively. Conclusions The TNM classification provides significant prognostic information for Xp11.2 tRCC. A relatively active surveillance algorithm is recommended, and cytoreduction surgery is an effective approach for recurrent Xp11.2 tRCC. Larger studies are required to more extensively investigate the recurrence of these potentially aggressive tumors.

  2. Postoperative recurrence of adult renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion

    PubMed Central

    Wang, Zhen; Liu, Ning; Li, Xiaogong; Zhang, Gutian; Li, Dongmei; Guo, Hongqian

    2017-01-01

    Objective To analyze the postoperative recurrence of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion (Xp11.2 tRCC). Methods This retrospective study was approved by the institutional review board and performed in accordance with the ethical standards established by the institution. Demographic, clinical, pathological, and follow-up data were compiled for the study cohort. Results During a mean follow-up of 41.3 months (range, 3–104 months), 8 of 34 patients with Xp11.2 tRCC were confirmed to have recurrence. Three of these patients died with poor outcomes due to a vena cava tumor embolus, and one died of distant metastasis 48 months after the initial nephrectomy during which lymph node metastasis was found. Three patients survived after cytoreduction surgery. One patient was diagnosed with lung metastasis 11 months postoperatively. Conclusions The TNM classification provides significant prognostic information for Xp11.2 tRCC. A relatively active surveillance algorithm is recommended, and cytoreduction surgery is an effective approach for recurrent Xp11.2 tRCC. Larger studies are required to more extensively investigate the recurrence of these potentially aggressive tumors. PMID:28587544

  3. Design and testing of 45 kV, 50 kHz pulse power supply for dielectric barrier discharges

    NASA Astrophysics Data System (ADS)

    Sharma, Surender Kumar; Shyam, Anurag

    2016-10-01

    The design, construction, and testing of high frequency, high voltage pulse power supply are reported. The purpose of the power supply is to generate dielectric barrier discharges for industrial applications. The power supply is compact and has the advantage of low cost, over current protection, and convenient control for voltage and frequency selection. The power supply can generate high voltage pulses of up to 45 kV at the repetitive frequency range of 1 kHz-50 kHz with 1.2 kW input power. The output current of the power supply is limited to 500 mA. The pulse rise time and fall time are less than 2 μs and the pulse width is 2 μs. The power supply is short circuit proof and can withstand variable plasma load conditions. The power supply mainly consists of a half bridge series resonant converter to charge an intermediate capacitor, which discharges through a step-up transformer at high frequency to generate high voltage pulses. Semiconductor switches and amorphous cores are used for power modulation at higher frequencies. The power supply is tested with quartz tube dielectric barrier discharge load and worked stably. The design details and the performance of the power supply on no load and dielectric barrier discharge load are presented.

  4. Design and testing of 45 kV, 50 kHz pulse power supply for dielectric barrier discharges.

    PubMed

    Sharma, Surender Kumar; Shyam, Anurag

    2016-10-01

    The design, construction, and testing of high frequency, high voltage pulse power supply are reported. The purpose of the power supply is to generate dielectric barrier discharges for industrial applications. The power supply is compact and has the advantage of low cost, over current protection, and convenient control for voltage and frequency selection. The power supply can generate high voltage pulses of up to 45 kV at the repetitive frequency range of 1 kHz-50 kHz with 1.2 kW input power. The output current of the power supply is limited to 500 mA. The pulse rise time and fall time are less than 2 μs and the pulse width is 2 μs. The power supply is short circuit proof and can withstand variable plasma load conditions. The power supply mainly consists of a half bridge series resonant converter to charge an intermediate capacitor, which discharges through a step-up transformer at high frequency to generate high voltage pulses. Semiconductor switches and amorphous cores are used for power modulation at higher frequencies. The power supply is tested with quartz tube dielectric barrier discharge load and worked stably. The design details and the performance of the power supply on no load and dielectric barrier discharge load are presented.

  5. Design, characterization and experimental validation of a compact, flexible pulsed power architecture for ex vivo platelet activation

    PubMed Central

    Caiafa, Antonio; Jiang, Yan; Klopman, Steve; Morton, Christine; Torres, Andrew S.; Loveless, Amanda M.; Neculaes, V. Bogdan

    2017-01-01

    Electric pulses can induce various changes in cell dynamics and properties depending upon pulse parameters; however, pulsed power generators for in vitro and ex vivo applications may have little to no flexibility in changing the pulse duration, rise- and fall-times, or pulse shape. We outline a compact pulsed power architecture that operates from hundreds of nanoseconds (with the potential for modification to tens of nanoseconds) to tens of microseconds by modifying a Marx topology via controlling switch sequences and voltages into each capacitor stage. We demonstrate that this device can deliver pulses to both low conductivity buffers, like standard pulsed power supplies used for electroporation, and higher conductivity solutions, such as blood and platelet rich plasma. We further test the effectiveness of this pulse generator for biomedical applications by successfully activating platelets ex vivo with 400 ns and 600 ns electric pulses. This novel bioelectrics platform may provide researchers with unprecedented flexibility to explore a wide range of pulse parameters that may induce phenomena ranging from intracellular to plasma membrane manipulation. PMID:28746392

  6. Integrated Pulse Detonation Propulsion and Magnetohydrodynamic Power

    NASA Technical Reports Server (NTRS)

    Litchford, Ron J.

    2001-01-01

    The prospects for realizing an integrated pulse detonation propulsion and magnetohydrodynamic (MHD) power system are examined. First, energy requirements for direct detonation initiation of various fuel-oxygen and fuel-air mixtures are deduced from available experimental data and theoretical models. Second, the pumping power requirements for effective chamber scavenging are examined through the introduction of a scavenging ratio parameter and a scavenging efficiency parameter. A series of laboratory experiments were carried out to investigate the basic engineering performance characteristics of a pulse detonation-driven MHD electric power generator. In these experiments, stoichiometric oxy-acetylene mixtures seeded with a cesium hydroxide/methanol spray were detonated at atmospheric pressure in a 1-m-long tube having an i.d. of 2.54 cm. Experiments with a plasma diagnostic channel attached to the end of the tube confirmed the attainment of detonation conditions (p2/p1 approximately 34 and D approximately 2,400 m/sec) and enabled the direct measurement of current density and electrical conductivity (approximately = 6 S/m) behind the detonation wave front, In a second set of experiments, a 30-cm-long continuous electrode Faraday channel, having a height of 2.54 cm and a width of 2 cm, was attached to the end of the tube using an area transition duct. The Faraday channel was inserted in applied magnetic fields of 0.6 and 0.95 T, and the electrodes were connected to an active loading circuit to characterize power extraction dependence on load impedance while also simulating higher effective magnetic induction. The experiments indicated peak power extraction at a load impedance between 5 and 10 Omega. The measured power density was in reasonable agreement with a simple electrodynamic model incorporating a correction for near-electrode potential losses. The time-resolved thrust characteristics of the system were also measured, and it was found that the NM interaction

  7. Integrated Pulse Detonation Propulsion and Magnetohydrodynamic Power

    NASA Technical Reports Server (NTRS)

    Litchford, R. J.; Lyles, Garry M. (Technical Monitor)

    2001-01-01

    The prospects for realizing an integrated pulse detonation propulsion and magnetohydrodynamic (MHD) power system are examined. First, energy requirements for direct detonation initiation of various fuel-oxygen and fuel-air mixtures are deduced from available experimental data and theoretical models. Second, the pumping power requirements for effective chamber scavenging are examined through the introduction of a scavenging ratio parameter and a scavenging efficiency parameter. A series of laboratory experiments were carried out to investigate the basic engineering performance characteristics of a pulse detonation-driven MHD electric power generator. In these experiments, stoichiometric oxy-acetylene mixtures seeded with a cesium hydroxide/methanol spray were detonated at atmospheric pressure in a 1-m-long tube having an i.d. of 2.54 cm. Experiments with a plasma diagnostic channel attached to the end of the tube confirmed the attainment of detonation conditions (p(sub 2)/p(sub 1) approx. 34 and D approx. 2,400 m/sec) and enabled the direct measurement of current density and electrical conductivity (=6 S/m) behind the detonation wave front. In a second set of experiments, a 30-cm-long continuous electrode Faraday channel, having a height of 2.54 cm and a width of 2 cm, was attached to the end of the tube using an area transition duct. The Faraday channel was inserted in applied magnetic fields of 0.6 and 0.95 T. and the electrodes were connected to an active loading circuit to characterize power extraction dependence on load impedance while also simulating higher effective magnetic induction. The experiments indicated peak power extraction at a load impedance between 5 and 10 Ohm. The measured power density was in reasonable agreement with a simple electrodynamic model incorporating a correction for near-electrode potential losses. The time-resolved thrust characteristics of the system were also measured, and it was found that the MHD interaction exerted a

  8. Xeroderma Pigmentosum: Low Prevalence of Germline XPA Mutations in a Brazilian XP Population

    PubMed Central

    Santiago, Karina Miranda; França de Nóbrega, Amanda; Rocha, Rafael Malagoli; Rogatto, Silvia Regina; Achatz, Maria Isabel

    2015-01-01

    Xeroderma pigmentosum (XP) is a rare autosomal recessive disorder characterized by DNA repair defects that cause photophobia, sunlight-induced cancers, and neurodegeneration. Prevalence of germline mutations in the nucleotide excision repair gene XPA vary significantly in different populations. No Brazilian patients have been reported to carry a germline mutation in this gene. In this study, the germline mutational status of XPA was determined in Brazilian patients exhibiting major clinical features of XP syndrome. The study was conducted on 27 unrelated patients from select Brazilian families. A biallelic inactivating transition mutation c.619C>T (p.Arg207Ter) was identified in only one patient with a history of neurological impairment and mild skin abnormalities. These findings suggest that XP syndrome is rarely associated with inherited disease-causing XPA mutations in the Brazilian population. Additionally, this report demonstrates the effectiveness of genotype-phenotype correlation as a valuable tool to guide direct genetic screening. PMID:25913378

  9. Xeroderma pigmentosum: low prevalence of germline XPA mutations in a Brazilian XP population.

    PubMed

    Santiago, Karina Miranda; França de Nóbrega, Amanda; Rocha, Rafael Malagoli; Rogatto, Silvia Regina; Achatz, Maria Isabel

    2015-04-22

    Xeroderma pigmentosum (XP) is a rare autosomal recessive disorder characterized by DNA repair defects that cause photophobia, sunlight-induced cancers, and neurodegeneration. Prevalence of germline mutations in the nucleotide excision repair gene XPA vary significantly in different populations. No Brazilian patients have been reported to carry a germline mutation in this gene. In this study, the germline mutational status of XPA was determined in Brazilian patients exhibiting major clinical features of XP syndrome. The study was conducted on 27 unrelated patients from select Brazilian families. A biallelic inactivating transition mutation c.619C>T (p.Arg207Ter) was identified in only one patient with a history of neurological impairment and mild skin abnormalities. These findings suggest that XP syndrome is rarely associated with inherited disease-causing XPA mutations in the Brazilian population. Additionally, this report demonstrates the effectiveness of genotype-phenotype correlation as a valuable tool to guide direct genetic screening.

  10. Low and High-Power Inductive Pulsed Plasma Thruster Development Testing at NASA-MSFC

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Martin, Adam K.; Greve, Christine M.; Riley, Daniel P.

    2017-01-01

    The inductive pulsed plasma thruster (IPPT) is an electromagnetic plasma accelerator that has been identified in NASA roadmaps as an enabling propulsion technology for some niche low-power missions and for high-power in-space propulsion needs. The IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged producing a high current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. Thrusters of this type possess many demonstrated and potential benefits that make them worthy of continued investigation. The electrodeless nature of these thrusters eliminates the lifetime and contamination issues associated with electrode erosion in conventional electric thrusters. Also, a wider variety of propellants are accessible when compatibility with metallic electrodes in no longer an issue. IPPTs have been successfully operated using propellants like ammonia, hydrazine, and CO2, and there is no fundamental reason why they would not operate on other in situ propellants like H2O. It is well-known that pulsed accelerators can maintain constant specific impulse (I(sub sp)) and thrust efficiency (eta(sub t)) over a wide range of input power levels by adjusting the pulse rate to hold the discharge energy per pulse constant. It has also been demonstrated that an inductive pulsed plasma thruster can operate in a regime where eta(sub t) is relatively constant over a wide range of I(sub sp) values (3000-8000 s). Finally, thrusters in this class have operated in single-pulse mode at high energy per pulse, and by increasing the pulse rate they offer the potential to process very high levels

  11. Rapidly progressing renal cell carcinoma associated with Xp11.2 translocations: a case report

    PubMed Central

    2012-01-01

    Introduction Renal cell carcinoma associated with Xp11.2 translocations is frequently reported in children, but adult-onset is rare. Here, the case of an adult male who developed a renal cell carcinoma associated with Xp11.2 translocations is presented. Case presentation A 38-year-old Asian man presented with left back pain and macroscopic hematuria. Computed tomography revealed a left renal tumor (T3N2M0), and a left radical nephrectomy was performed. Hematoxylin-eosin staining revealed papillary architecture and clear or eosinophilic cytoplasm, and the diagnosis of renal cell carcinoma associated with Xp11.2 translocations/TFE3 gene fusion was made by the immunohistochemical determination of transcription factor E3 protein. In spite of adjuvant therapy with α-interferon, a recurrent tumor was found in his left lung by computed tomography three months after the nephrectomy. Interleukin-2, tyrosine kinase inhibitors and mammalian target of rapamycin inhibitors showed no effect on tumor progression. Conclusions Renal cell carcinomas associated with Xp11.2 translocations have an aggressive clinical course in adults. Strict diagnosis using the immunohistochemistry of transcription factor E3 protein is important to predict the prognosis of such patients and new strategies need to be determined to treat patients with these tumors PMID:22738297

  12. Rapidly progressing renal cell carcinoma associated with Xp11.2 translocations: a case report.

    PubMed

    Morii, Akihiro; Fujiuchi, Yasuyoshi; Nomoto, Kazuhiro; Komiya, Akira; Fuse, Hideki

    2012-06-27

    Renal cell carcinoma associated with Xp11.2 translocations is frequently reported in children, but adult-onset is rare. Here, the case of an adult male who developed a renal cell carcinoma associated with Xp11.2 translocations is presented. A 38-year-old Asian man presented with left back pain and macroscopic hematuria. Computed tomography revealed a left renal tumor (T3N2M0), and a left radical nephrectomy was performed. Hematoxylin-eosin staining revealed papillary architecture and clear or eosinophilic cytoplasm, and the diagnosis of renal cell carcinoma associated with Xp11.2 translocations/TFE3 gene fusion was made by the immunohistochemical determination of transcription factor E3 protein. In spite of adjuvant therapy with α-interferon, a recurrent tumor was found in his left lung by computed tomography three months after the nephrectomy. Interleukin-2, tyrosine kinase inhibitors and mammalian target of rapamycin inhibitors showed no effect on tumor progression. Renal cell carcinomas associated with Xp11.2 translocations have an aggressive clinical course in adults. Strict diagnosis using the immunohistochemistry of transcription factor E3 protein is important to predict the prognosis of such patients and new strategies need to be determined to treat patients with these tumors.

  13. High-peak-power microwave pulses: effects on heart rate and blood pressure in unanesthetized rats.

    PubMed

    Jauchem, J R; Frei, M R

    1995-10-01

    Exposure sources capable of generating high-peak-power microwave pulses, with relatively short pulse widths, have recently been developed. Studies of the effect of these sources on the cardiovascular systems of animals have not been reported previously. We exposed 14 unanesthetized male Sprague-Dawley rats to 10 high-peak-power microwave pulses generated by a transformer-energized megawatt pulsed output (TEMPO) microwave source, at frequencies ranging from 1.2-1.8 GHz. Peak power densities were as high as 51.6 kW/cm2. At 14 d prior to irradiation, the animals were implanted with chronic aortic cannulae. With appropriate shielding of the transducer, blood pressure recordings were obtained during microwave pulsing. In a preliminary series of exposures at 1.7-1.8 GHz (peak power density 3.3-6.5 kW/cm2), an immediate but transient increase in mean arterial blood pressure (significant) and decrease in heart rate (non-significant) were observed. A loud noise was associated with each pulse produced by the TEMPO; this factor was subsequently attenuated. In a second series of exposures at 1.2-1.4 GHz (peak power density 14.6-51.6 kW/cm2), there were no significant changes in mean arterial blood pressure or heart rate during microwave exposure. The earlier significant increase in blood pressure that occurred during microwave exposure appeared to be related to the sharp noise produced by the TEMPO source. After appropriate sound attenuation, there were no significant effects of exposure to the microwave pulses.

  14. Microsecond gain-switched master oscillator power amplifier (1958 nm) with high pulse energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ke Yin; Weiqiang Yang; Bin Zhang

    2014-02-28

    An all-fibre master oscillator power amplifier (MOPA) emitting high-energy pulses at 1958 nm is presented. The seed laser is a microsecond gain-switched thulium-doped fibre laser (TDFL) pumped with a commercial 1550-nm pulsed fibre laser. The TDFL operates at a repetition rate f in the range of 10 to 100 kHz. The two-stage thulium-doped fibre amplifier is built to scale the energy of the pulses generated by the seed laser. The maximum output pulse energy higher than 0.5 mJ at 10 kHz is achieved which is comparable with the theoretical maximum extractable pulse energy. The slope efficiency of the second stagemore » amplifier with respect to the pump power is 30.4% at f = 10 kHz. The wavelength of the output pulse laser is centred near 1958 nm at a spectral width of 0.25 nm after amplification. Neither nonlinear effects nor significant amplified spontaneous emission (ASE) is observed in the amplification experiments. (lasers)« less

  15. Performance of Low-Power Pulsed Arcjets

    NASA Technical Reports Server (NTRS)

    Burton, Rodney L.

    1995-01-01

    The Electric Propulsion Laboratory at UIUC has in place all the capability and diagnostics required for performance testing of low power pulsed and DC arcjets. The UIUC thrust stand is operating with excellent accuracy and sensitivity at very low thrust levels. An important aspect of the experimental setup is the use of a PID controller to maintain a constant thruster position, which reduces hysterisis effects. Electrical noise from the arcjet induces some noise into the thrust signal, but this does not affect the measurement.

  16. Switching power pulse system

    DOEpatents

    Aaland, K.

    1983-08-09

    A switching system for delivering pulses of power from a source to a load using a storage capacitor charged through a rectifier, and maintained charged to a reference voltage level by a transistor switch and voltage comparator. A thyristor is triggered to discharge the storage capacitor through a saturable reactor and fractional turn saturable transformer having a secondary to primary turn ratio N of n:l/n = n[sup 2]. The saturable reactor functions as a soaker'' while the thyristor reaches saturation, and then switches to a low impedance state. The saturable transformer functions as a switching transformer with high impedance while a load coupling capacitor charges, and then switches to a low impedance state to dump the charge of the storage capacitor into the load through the coupling capacitor. The transformer is comprised of a multilayer core having two secondary windings tightly wound and connected in parallel to add their output voltage and reduce output inductance, and a number of single turn windings connected in parallel at nodes for the primary winding, each single turn winding linking a different one of the layers of the multilayer core. The load may be comprised of a resistive beampipe for a linear particle accelerator and capacitance of a pulse forming network. To hold off discharge of the capacitance until it is fully charged, a saturable core is provided around the resistive beampipe to isolate the beampipe from the capacitance until it is fully charged. 5 figs.

  17. Ruthenium Oxide Electrochemical Super Capacitor Optimization for Pulse Power Applications

    NASA Technical Reports Server (NTRS)

    Merryman, Stephen A.; Chen, Zheng

    2000-01-01

    Electrical actuator systems are being pursued as alternatives to hydraulic systems to reduce maintenance time, weight and costs while increasing reliability. Additionally, safety and environmental hazards associated with the hydraulic fluids can be eliminated. For most actuation systems, the actuation process is typically pulsed with high peak power requirements but with relatively modest average power levels. The power-time requirements for electrical actuators are characteristic of pulsed power technologies where the source can be sized for the average power levels while providing the capability to achieve the peak requirements. Among the options for the power source are battery systems, capacitor systems or battery-capacitor hybrid systems. Battery technologies are energy dense but deficient in power density; capacitor technologies are power dense but limited by energy density. The battery-capacitor hybrid system uses the battery to supply the average power and the capacitor to meet the peak demands. It has been demonstrated in previous work that the hybrid electrical power source can potentially provide a weight savings of approximately 59% over a battery-only source. Electrochemical capacitors have many properties that make them well-suited for electrical actuator applications. They have the highest demonstrated energy density for capacitive storage (up to 100 J/g), have power densities much greater than most battery technologies (greater than 30kW/kg), are capable of greater than one million charge-discharge cycles, can be charged at extremely high rates, and have non-explosive failure modes. Thus, electrochemical capacitors exhibit a combination of desirable battery and capacitor characteristics.

  18. Nine-channel mid-power bipolar pulse generator based on a field programmable gate array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haylock, Ben, E-mail: benjamin.haylock2@griffithuni.edu.au; Lenzini, Francesco; Kasture, Sachin

    Many channel arbitrary pulse sequence generation is required for the electro-optic reconfiguration of optical waveguide networks in Lithium Niobate. Here we describe a scalable solution to the requirement for mid-power bipolar parallel outputs, based on pulse patterns generated by an externally clocked field programmable gate array. Positive and negative pulses can be generated at repetition rates up to 80 MHz with pulse width adjustable in increments of 1.6 ns across nine independent outputs. Each channel can provide 1.5 W of RF power and can be synchronised with the operation of other components in an optical network such as light sourcesmore » and detectors through an external clock with adjustable delay.« less

  19. Structure and Barr body formation of an Xp + chromosome with two inactivation centers.

    PubMed Central

    Daly, R F; Patau, K; Therman, E; Sarto, G E

    1977-01-01

    A patients with seizures, Von Willebrand disease, and symptoms of Turner syndrome was a chromosomal mosaic. In blood culture (1974), 56% of the cells were 45, X 33% 46, XXp+ and 11% 47,XXp + Xp +; in the skin, no cells with 47 chromosomes were found. Presumably the Xp + chromosome arose through a break in the Q-banded dark region next to the centromere on Xp to which an Xq had been attached. The abnormal X was late-labeling and formed a larger than normal Barr body. Of the chromatin-positive fibroblasts, 18.2% showed bipartite Barr bodies, which agrees with the hypothesis that the X inactivation center lies on the proximal part of the Xq. On the basis of the structure and behavior of the bipartite bodies in the present patient, as compared to those formed by other chromosomes with two presumed inactivation centers, we propose that the dark region next to the centromere of Xp remains active in the inactive X. In cells with 45,X and 46,XY, this region has the same relative size, whereas it is significantly shorter in the active X of three females, including the present patient, with one abnormal X. We propose that this region on the active X reveals different states of activity, as reflected in its length, depending on how many other X chromosomes are in the cell. Images Fig. 1 Fig. 2 Fig. 3 PMID:299980

  20. High power parallel ultrashort pulse laser processing

    NASA Astrophysics Data System (ADS)

    Gillner, Arnold; Gretzki, Patrick; Büsing, Lasse

    2016-03-01

    The class of ultra-short-pulse (USP) laser sources are used, whenever high precession and high quality material processing is demanded. These laser sources deliver pulse duration in the range of ps to fs and are characterized with high peak intensities leading to a direct vaporization of the material with a minimum thermal damage. With the availability of industrial laser source with an average power of up to 1000W, the main challenge consist of the effective energy distribution and disposition. Using lasers with high repetition rates in the MHz region can cause thermal issues like overheating, melt production and low ablation quality. In this paper, we will discuss different approaches for multibeam processing for utilization of high pulse energies. The combination of diffractive optics and conventional galvometer scanner can be used for high throughput laser ablation, but are limited in the optical qualities. We will show which applications can benefit from this hybrid optic and which improvements in productivity are expected. In addition, the optical limitations of the system will be compiled, in order to evaluate the suitability of this approach for any given application.

  1. A rare cause of childhood renal cysts: Xp11.2 translocation renal cell carcinoma.

    PubMed

    Taşkınlar, Hakan; Avlan, Dinçer; Çıtak, Çağlar; Polat, Ayşe; Naycı, Ali

    2015-01-01

    Pediatric renal cysts are rare, usually asymptomatic and incidentally detected in children. Cyst associated renal cell carcinoma (RCC) or cystic RCC is extremely rare in children. Bosniak classification system has been accepted for the management of cystic renal masses. Xp11.2 translocation RCC is a recently classified distinct subtype and usually affects children and adolescents. We report the case of a 10-year-old girl with Xp11.2 translocation RCC from a cyst of the right kidney.

  2. Experiment and theoretical study of the propagation of high power microwave pulse in air breakdown environment

    NASA Technical Reports Server (NTRS)

    Kuo, S. P.; Ren, A.; Zhang, Y. S.

    1991-01-01

    In the study of the propagation of high power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. In the very high power region, one has to prevent the cutoff reflection caused by the excessive ionization in the background air. A frequency auto-conversion process which can lead to reflectionless propagation of powerful EM pulses in self-generated plasmas is studied. The theory shows that under the proper conditions the carrier frequency, omega, of the pulse will indeed shift upward with the growth of plasma frequency, omega(sub pe). Thus, the plasma during breakdown will always remain transparent to the pulse (i.e., omega greater than omega(sub pe)). A chamber experiment to demonstrate the frequency auto-conversion during the pulse propagation through the self-generated plasma is then conducted in a chamber. The detected frequency shift is compared with the theoretical result calculated y using the measured electron density distribution along the propagation path of the pulse. Good agreement between the theory and the experiment results is obtained.

  3. High power pulsed sources based on fiber amplifiers

    NASA Astrophysics Data System (ADS)

    Canat, Guillaume; Jaouën, Yves; Mollier, Jean-Claude; Bouzinac, Jean-Pierre; Cariou, Jean-Pierre

    2017-11-01

    Cladding-pumped rare-earth-doped fiber laser technologies are currently among the best sources for high power applications. Theses extremely compact and robust sources appoint them as good candidate for aeronautical and space applications. The double-clad (DC) fiber converts the poor beamquality of high-power large-area pump diodes from the 1st cladding to laser light at another wavelength guided in an active single-mode core. High-power coherent MOPA (Master Oscillator Power Amplifier) sources (several 10W CW or several 100W in pulsed regime) will soon be achieved. Unfortunately it also brings nonlinear effects which quickly impairs output signal distortions. Stimulated Brillouin scattering (SBS) and optical parametric amplification (OPA) have been shown to be strong limitations. Based on amplifier modeling and experiments we discuss the performances of these sources.

  4. Considerations for human exposure standards for fast-rise-time high-peak-power electromagnetic pulses.

    PubMed

    Merritt, J H; Kiel, J L; Hurt, W D

    1995-06-01

    Development of new emitter systems capable of producing high-peak-power electromagnetic pulses with very fast rise times and narrow pulse widths is continuing. Such directed energy weapons systems will be used in the future to defeat electronically vulnerable targets. Human exposures to these pulses can be expected during testing and operations. Development of these technologies for radar and communications purposes has the potential for wider environmental exposure, as well. Current IEEE C95.1-1991 human exposure guidelines do not specifically address these types of pulses, though limits are stated for pulsed emissions. The process for developing standards includes an evaluation of the relevant bioeffects data base. A recommendation has been made that human exposure to ultrashort electromagnetic pulses that engender electromagnetic transients, called precursor waves, should be avoided. Studies that purport to show the potential for tissue damage induced by such pulses were described. The studies cited in support of the recommendation were not relevant to the issues of tissue damage by propagated pulses. A number of investigations are cited in this review that directly address the biological effects of electromagnetic pulses. These studies have not shown evidence of tissue damage as a result of exposure to high-peak-power pulsed microwaves. It is our opinion that the current guidelines are sufficiently protective for human exposure to these pulses.

  5. A Novel Nanosecond Pulsed Power Unit for the Formation of ·OH in Water

    NASA Astrophysics Data System (ADS)

    Li, Shengli; Hu, Sheng; Zhang, Han

    2012-04-01

    A novel nanosecond pulsed power unit was developed for plasma treatment of wastewater, based on the theory of magnetic pulse compression and semiconductor opening switch (SOS). The peak value, rise time and pulse duration of the output voltage were observed to be -51 kV, 60 ns and 120 ns, respectively. The concentrations of ·OH generated by the novel nanosecond pulsed plasma power were determined using the method of high-performance liquid chromatography (HPLC). The results showed that the concentrations of ·OH increased with the increase in peak voltage, and the generation rates of ·OH were 4.1 × 10-10 mol/s, 5.7 × 10-10 mol/s, and 7.7 × 10-10 mol/s at 30 kV, 35 kV, and 40 kV, respectively. The efficiency of OH generation was found to be independent of the input parameters for applied power, with an average value of 3.23×10-12 mol/J obtained.

  6. Experimental investigation of high power pulsed 2.8 μm Er3+-doped ZBLAN fiber lasers

    NASA Astrophysics Data System (ADS)

    Shen, Yanlong; Wang, Yishan; Huang, Ke; Luan, Kunpeng; Chen, Hongwei; Tao, Mengmeng; Yu, Li; Yi, Aiping; Si, Jinhai

    2017-05-01

    We report on the recent progress on high power pulsed 2.8 μm Er3+-doped ZBLAN fiber laser through techniques of passively and actively Q-switching in our research group. In passively Q-switched operation, a diode-cladding-pumped mid-infrared passively Q-switched Er3+-doped ZBLAN fiber laser with an average output power of watt-level based on a semiconductor saturable absorber mirror (SESAM) was demonstrated. Stable pulse train was produced at a slope efficient of 17.8% with respect to launched pump power. The maximum average power of 1.01 W at a repetition rate of 146.3 kHz was achieved with a corresponding pulse energy of 6.9 μJ. The maximum peak power was calculated to be 21.9 W. In actively Q-switched operation, a diode-pumped actively Q-switched Er3+-doped ZBLAN fiber laser at 2.8 μm with an optical chopper was reported. The maximum laser pulse energy of up to 130 μJ and a pulse width of 127.3 ns at a repetition rate of 10 kHz with an operating wavelength of 2.78 μm was obtained, yielding the maximum peak power of exceeding 1.1 kW.

  7. A case of PSF-TFE3 gene fusion in Xp11.2 renal cell carcinoma with melanotic features.

    PubMed

    Zhan, He-Qin; Chen, Hong; Wang, Chao-Fu; Zhu, Xiong-Zeng

    2015-03-01

    Xp11.2 translocation renal cell carcinoma (Xp11.2 RCC) with PSF-TFE3 gene fusion is a rare neoplasm. Only 22 cases of Xp11.2 RCCs with PSF-TFE3 have been reported to date. We describe an additional case of Xp11.2 RCC with PSF-TFE3 showing melanotic features. Microscopically, the histologic features mimic clear cell renal cell carcinoma. However, the dark-brown pigments were identified and could be demonstrated as melanins. Immunohistochemically, the tumor cells were widely positive for CD10, human melanoma black 45, and TFE3 but negative for cytokeratins, vimentin, Melan-A, microphthalmia-associated transcription factor, smooth muscle actin, and S-100 protein. Genetically, we demonstrated PSF-TFE3 fusion between exon 9 of PSF and exon 5 of TFE3. The patient was free of disease with 50 months of follow-up. The prognosis of this type of tumor requires more cases because of limited number of cases and follow-up period. Xp11.2 RCC with PSF-TFE3 inevitably requires differentiation from other kidney neoplasms. Immunohistochemical and molecular genetic analyses are essential for accurate diagnosis. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Ion density evolution in a high-power sputtering discharge with bipolar pulsing

    NASA Astrophysics Data System (ADS)

    Britun, N.; Michiels, M.; Godfroid, T.; Snyders, R.

    2018-06-01

    Time evolution of sputtered metal ions in high power impulse magnetron sputtering (HiPIMS) discharge with a positive voltage pulse applied after a negative one (regime called "bipolar pulse HiPIMS"—BPH) is studied using 2-D density mapping. It is demonstrated that the ion propagation dynamics is mainly affected by the amplitude and duration of the positive pulse. Such effects as ion repulsion from the cathode and the ionization zone shrinkage due to electron drift towards the cathode are clearly observed during the positive pulse. The BPH mode also alters the film crystallographic structure, as observed from X-ray diffraction analysis.

  9. Renal cell carcinoma associated with transcription factor E3 expression and Xp11.2 translocation: incidence, characteristics, and prognosis.

    PubMed

    Klatte, Tobias; Streubel, Berthold; Wrba, Friedrich; Remzi, Mesut; Krammer, Barbara; de Martino, Michela; Waldert, Matthias; Marberger, Michael; Susani, Martin; Haitel, Andrea

    2012-05-01

    We studied the characteristics and prognosis of renal cell carcinoma (RCC) associated with Xp11.2 translocation and transcription factor E3 (TFE3) expression and determined the need for genetic analysis in routine diagnostics. Of 848 consecutive cases, 75 showed microscopic features suggestive of Xp11.2 translocation RCC or occurred in patients 40 years or younger. Of these cases, 17 (23%) showed strong nuclear TFE3 immunostaining, which was associated with more advanced tumors and inverse prognosis in univariate (P = .032) but not multivariate (P = .404) analysis. With fluorescence in situ hybridization and polymerase chain reaction, only 2 cases showed alterations of the X chromosome and the ASPL-TFE3 gene fusion, respectively. In our laboratory, the predictive value of TFE3 expression for the Xp11.2 translocation was 12%. Strong nuclear TFE3 expression is associated with metastatic spread and a poor prognosis. In our laboratory, TFE3 is not diagnostic for Xp11.2 translocation RCC. Diagnosis of Xp11.2 translocation RCC may be made only genetically.

  10. Formation of nanosecond SBS-compressed pulses for pumping an ultra-high power parametric amplifier

    NASA Astrophysics Data System (ADS)

    Kuz’min, A. A.; Kulagin, O. V.; Rodchenkov, V. I.

    2018-04-01

    Compression of pulsed Nd : glass laser radiation under stimulated Brillouin scattering (SBS) in perfluorooctane is investigated. Compression of 16-ns pulses at a beam diameter of 30 mm is implemented. The maximum compression coefficient is 28 in the optimal range of laser pulse energies from 2 to 4 J. The Stokes pulse power exceeds that of the initial laser pulse by a factor of about 11.5. The Stokes pulse jitter (fluctuations of the Stokes pulse exit time from the compressor) is studied. The rms spread of these fluctuations is found to be 0.85 ns.

  11. A rare cause of childhood renal cysts: Xp11.2 translocation renal cell carcinoma

    PubMed Central

    Taşkınlar, Hakan; Avlan, Dinçer; Çıtak, Çağlar; Polat, Ayşe; Naycı, Ali

    2015-01-01

    Pediatric renal cysts are rare, usually asymptomatic and incidentally detected in children. Cyst associated renal cell carcinoma (RCC) or cystic RCC is extremely rare in children. Bosniak classification system has been accepted for the management of cystic renal masses. Xp11.2 translocation RCC is a recently classified distinct subtype and usually affects children and adolescents. We report the case of a 10-year-old girl with Xp11.2 translocation RCC from a cyst of the right kidney. PMID:25624966

  12. Simultaneous detection of eight avian influenza A virus subtypes by multiplex reverse transcription-PCR using a GeXP analyser.

    PubMed

    Li, Meng; Xie, Zhixun; Xie, Zhiqin; Liu, Jiabo; Xie, Liji; Deng, Xianwen; Luo, Sisi; Fan, Qing; Huang, Li; Huang, Jiaoling; Zhang, Yanfang; Zeng, Tingting; Wang, Sheng

    2018-04-18

    Recent studies have demonstrated that at least eight subtypes of avian influenza virus (AIV) can infect humans, including H1, H2, H3, H5, H6, H7, H9 and H10. A GeXP analyser-based multiplex reverse transcription (RT)-PCR (GeXP-multiplex RT-PCR) assay was developed in our recent studies to simultaneously detect these eight AIV subtypes using the haemagglutinin (HA) gene. The assay consists of chimeric primer-based PCR amplification with fluorescent labelling and capillary electrophoresis separation. RNA was extracted from chick embryo allantoic fluid or liquid cultures of viral isolates. In addition, RNA synthesised via in vitro transcription was used to determine the specificity and sensitivity of the assay. After selecting the primer pairs, their concentrations and GeXP-multiplex RT-PCR conditions were optimised. The established GeXP-multiplex RT-PCR assay can detect as few as 100 copies of premixed RNA templates. In the present study, 120 clinical specimens collected from domestic poultry at live bird markets and from wild birds were used to evaluate the performance of the assay. The GeXP-multiplex RT-PCR assay specificity was the same as that of conventional RT-PCR. Thus, the GeXP-multiplex RT-PCR assay is a rapid and relatively high-throughput method for detecting and identifying eight AIV subtypes that may infect humans.

  13. Laser pulse power transmission limits of silica fibers with antireflective coating

    NASA Astrophysics Data System (ADS)

    Meister, St.; Wosniok, A.; Seewald, G.; Scharfenorth, Ch.; Eichler, H. J.

    2005-04-01

    Multimode optical fibers are used for the transmission of high power laser pulses and as phase conjugated mirrors by stimulated Brillouin scattering. Both applications are enhanced by antireflection coatings on the fiber end-faces. Fiber transmissions reach more than 99.5% for pulse energies below the threshold of stimulated Brillouin scattering. Laser-induced damage thresholds of the fibers coated with Ta2O5 / SiO2 were measured at 1064 nm and 24 ns pulse duration. A damage threshold of up to 101 J/cm2 could be achieved. The damage morphology was investigated using atomic force microscopy and scanning electron microscopy.

  14. Wind-Tunnel Tests of the 1/9-Scale Model of the Curtiss XP-62 Airplane with Various Vertical Tail Arrangements

    NASA Technical Reports Server (NTRS)

    Wallace, Arthur R.; Recant, I.G.

    1943-01-01

    The effect of various vertical tail arrangements upon the stability and control characteristics of an XP-62 fighter model was investigated. Rudder-free yaw characteristics with take-off power and flaps deflected were satisfactory after dorsal fin modifications. Directional stability was obtained with all modified vertical tails. Satisfactory rudder effectiveness resulted partly because the dual-rotation propellers produced no asymmetric yawing moments. Pedal forces in sideslips were undesirably large but may be easily reduced.

  15. Laparoscopic radiofrequency ablation-assisted enucleation of Xp11.2 translocation renal cell carcinoma: A case report

    PubMed Central

    XU, LINFENG; YANG, RONG; WANG, WEI; ZHANG, YIFEN; GAN, WEIDONG

    2014-01-01

    The current study presents a case of Xp11.2 translocation renal cell carcinoma (Xp11.2 RCC) in a 30-year-old female. The patient was referred to The Affiliated Drum Tower Hospital of the Medical College of Nanjing University (Nanjing, Jiangsu, China) due to a right renal tumor without evident symptoms, which was found by a routine physical examination. A computed tomography (CT) scan indicated that the mass exhibited cystic and solid components. The patient underwent laparoscopic radiofrequency ablation-assisted enucleation. Immunohistochemistry revealed intense nuclear staining for transcription factor E3 protein in the cancer cells. The patient was diagnosed with Xp11.2 RCC. The urological and radiological outcomes remained satisfactory after >2.5 years of follow-up. PMID:25120696

  16. Laparoscopic radiofrequency ablation-assisted enucleation of Xp11.2 translocation renal cell carcinoma: A case report.

    PubMed

    Xu, Linfeng; Yang, Rong; Wang, Wei; Zhang, Yifen; Gan, Weidong

    2014-09-01

    The current study presents a case of Xp11.2 translocation renal cell carcinoma (Xp11.2 RCC) in a 30-year-old female. The patient was referred to The Affiliated Drum Tower Hospital of the Medical College of Nanjing University (Nanjing, Jiangsu, China) due to a right renal tumor without evident symptoms, which was found by a routine physical examination. A computed tomography (CT) scan indicated that the mass exhibited cystic and solid components. The patient underwent laparoscopic radiofrequency ablation-assisted enucleation. Immunohistochemistry revealed intense nuclear staining for transcription factor E3 protein in the cancer cells. The patient was diagnosed with Xp11.2 RCC. The urological and radiological outcomes remained satisfactory after >2.5 years of follow-up.

  17. [Application of polyclonal break-apart probes in the diagnosis of Xp11.2 translocation renal cell carcinoma].

    PubMed

    Chen, Xiancheng; Gan, Weidong; Ye, Qing; Yang, Jun; Guo, Hongqian; Li, Dongmei

    2014-12-16

    To explore the value of self-designed fluorescent in situ hybridization (FISH) polyclonal break-apart probes specific for TFE3 gene in the diagnosis of Xp11.2 translocation renal cell carcinoma. All tissue samples were collected from 2006 to 2013, including Xp11.2 translocation renal cell carcinoma (n = 10), renal clear cell carcinoma (n = 10) and renal papillary cell carcinoma (n = 10). FISH was conducted for paraffin-embedded tumor tissue sections with probes. The types of fluorescence were observed by fluorescent microscopy to determine the existence or non-existence of translocated TFE3 gene. All sections were successfully probed. The split red and green signals within a single nucleus were detected simultaneously in 9 cases of Xp11.2 translocation renal cell carcinoma as diagnosed by traditional pathological and immunohistochemical methods. And it was consistent with the initial diagnosis. Detection of fusion signal in 1/10 and negative FISH result did not conform to the initial diagnosis. The fluorescent types of renal clear cell carcinoma and renal papillary cell carcinoma were all fusion signals. FISH tests were negative for renal clear and papillary cell carcinomas. Xp11.2 translocation renal cell carcinomas diagnosed by traditional pathological and immunohistochemical methods are sometimes misdiagnosed. Detecting the translocation of TFE3 gene with FISH polyclonal break-apart probes is both accurate and reliable for diagnosing Xp11.2 translocation renal cell carcinoma.

  18. Design of parallel transmission pulses for simultaneous multislice with explicit control for peak power and local specific absorption rate.

    PubMed

    Guérin, Bastien; Setsompop, Kawin; Ye, Huihui; Poser, Benedikt A; Stenger, Andrew V; Wald, Lawrence L

    2015-05-01

    To design parallel transmit (pTx) simultaneous multislice (SMS) spokes pulses with explicit control for peak power and local and global specific absorption rate (SAR). We design SMS pTx least-squares and magnitude least squares spokes pulses while constraining local SAR using the virtual observation points (VOPs) compression of SAR matrices. We evaluate our approach in simulations of a head (7T) and a body (3T) coil with eight channels arranged in two z-rows. For many of our simulations, control of average power by Tikhonov regularization of the SMS pTx spokes pulse design yielded pulses that violated hardware and SAR safety limits. On the other hand, control of peak power alone yielded pulses that violated local SAR limits. Pulses optimized with control of both local SAR and peak power satisfied all constraints and therefore had the best excitation performance under limited power and SAR constraints. These results extend our previous results for single slice pTx excitations but are more pronounced because of the large power demands and SAR of SMS pulses. Explicit control of local SAR and peak power is required to generate optimal SMS pTx excitations satisfying both the system's hardware limits and regulatory safety limits. © 2014 Wiley Periodicals, Inc.

  19. Renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion: radiological findings mimicking papillary subtype.

    PubMed

    Kato, Hiroki; Kanematsu, Masayuki; Yokoi, Shigeaki; Miwa, Kousei; Horie, Kengo; Deguchi, Takashi; Hirose, Yoshinobu

    2011-01-01

    The authors describe the computed tomography (CT) and magnetic resonance imaging (MRI) findings of an 18-year-old man with renal cell carcinoma (RCC) associated with the Xp11.2 translocation/transcription factor E3 (TFE3) gene fusion (Xp11 translocation carcinoma). The lesion was hyperdense on unenhanced CT, hypovascular on contrast-enhanced studies, hypointense on T2-weighted MR images, and hemosiderin deposition was suspected on phase-shift gradient-echo MR images. Histopathological specimens revealed pathological findings resembling papillary RCC predominantly and exhibited immunoreactivity for TFE3. Because there is often considerable morphological overlap between this carcinoma and papillary RCC, the imaging findings of Xp11 translocation carcinoma may be similar to those of the papillary subtype. Therefore, Xp11 translocation carcinoma should be considered, particularly in young patients when radiologic images demonstrate a renal tumor mimicking the papillary subtype. Copyright © 2010 Wiley-Liss, Inc.

  20. Developments on GM-Type Pulse Tube Cryorefrigerators with Large Cooling Power

    NASA Astrophysics Data System (ADS)

    Köttig, T.; Waldauf, A.; Thürk, M.; Seidel, P.

    2004-06-01

    Over the past several years the authors have participated in basic and prototype developments of four valve pulse tube refrigerators (FVPTR). Systematic studies have been carried out to characterize the basics of energy transport mechanisms, the flow distribution and loss mechanisms of this type of pulse tube refrigerator (PTR) with its active type of phase shifting. Based on the comprehension of these phenomena, several prototypes have been built and optimized for various applications. Recently a single-stage PTR in coaxial arrangement has been designed for maximum refrigeration power in the temperature range between 20 and 80 K limited by an available electrical input power of 7 kW. To reach this goal we used lead screens in the coldest part of the regenerator instead of spheres in order to decrease the pressure drop. The improvement of the regenerator prevents the reported fact that at higher temperatures the performance of a pulse tube with a regenerator partially filled with lead spheres can even be worse than a regenerator totally made of stainless steel. At the moment the cooler provides a cooling power of 120 W@74 K and 40 W@34 K. The minimum no-load temperature achieved is 18.6 K.

  1. Optically Isolated Control of the MOCHI LabJet High Power Pulsed Plasma Experiment

    NASA Astrophysics Data System (ADS)

    Carroll, Evan; Quinley, Morgan; von der Linden, Jens; You, Setthivoine

    2014-10-01

    The MOCHI LabJet experiment designed to investigate the dynamics of astrophysical jets at the University of Washington, requires high energy pulsed power supplies for plasma generation and sustainment. Two 600 μ F, 10 kV DC, pulse forming, power supplies have been specifically developed for this application. For safe and convenient user operation, the power supplies are controlled remotely with optical isolation. Three input voltage signals are required for relay actuation, adjusting bank charging voltage, and to fire the experiment: long duration DC signals, long duration user adjustable DC signals and fast trigger pulses with < μ s rise times. These voltage signals are generated from National Instruments timing cards via LabVIEW and are converted to optical signals by coupling photodiodes with custom electronic circuits. At the experiment, the optical signals are converted back to usable voltage signals using custom circuits. These custom circuits and experimental set-up are presented. This work is supported by US DOE Grant DE-SC0010340.

  2. Development of compact rapid charging power supply for capacitive energy storage in pulsed power drivers.

    PubMed

    Sharma, Surender Kumar; Shyam, Anurag

    2015-02-01

    High energy capacitor bank is used for primary electrical energy storage in pulsed power drivers. The capacitors used in these pulsed power drivers have low inductance, low internal resistance, and less dc life, so it has to be charged rapidly and immediately discharged into the load. A series resonant converter based 45 kV compact power supply is designed and developed for rapid charging of the capacitor bank with constant charging current up to 150 mA. It is short circuit proof, and zero current switching technique is used to commute the semiconductor switch. A high frequency resonant inverter switching at 10 kHz makes the overall size small and reduces the switching losses. The output current of the power supply is limited by constant on-time and variable frequency switching control technique. The power supply is tested by charging the 45 kV/1.67 μF and 15 kV/356 μF capacitor banks. It has charged the capacitor bank up to rated voltage with maximum charging current of 150 mA and the average charging rate of 3.4 kJ/s. The output current of the power supply is limited by reducing the switching frequency at 5 kHz, 3.3 kHz, and 1.7 kHz and tested with 45 kV/1.67 μF capacitor bank. The protection circuit is included in the power supply for over current, under voltage, and over temperature. The design details and the experimental testing results of the power supply for resonant current, output current, and voltage traces of the power supply with capacitive, resistive, and short circuited load are presented and discussed.

  3. Thermal Simulation of Switching Pulses in an Insulated Gate Bipolar Transistor (IGBT) Power Module

    DTIC Science & Technology

    2015-02-01

    executed with SolidWorks Flow Simulation , a computational fluid-dynamics code. The graph in Fig. 2 shows the timing and amplitudes of power pulses...defined a convective flow of air perpendicular to the bottom surface of the mounting plate, with a velocity of 10 ft/s. The thermal simulations were...Thermal Simulation of Switching Pulses in an Insulated Gate Bipolar Transistor (IGBT) Power Module by Gregory K Ovrebo ARL-TR-7210

  4. Ultrasonic Power Output Measurement by Pulsed Radiation Pressure

    PubMed Central

    Fick, Steven E.; Breckenridge, Franklin R.

    1996-01-01

    Direct measurements of time-averaged spatially integrated output power radiated into reflectionless water loads can be made with high accuracy using techniques which exploit the radiation pressure exerted by sound on all objects in its path. With an absorptive target arranged to intercept the entirety of an ultrasound beam, total beam power can be determined as accurately as the radiation force induced on the target can be measured in isolation from confounding forces due to buoyancy, streaming, surface tension, and vibration. Pulse modulation of the incident ultrasound at a frequency well above those characteristics of confounding phenomena provides the desired isolation and other significant advantages in the operation of the radiation force balance (RFB) constructed in 1974. Equipped with purpose-built transducers and electronics, the RFB is adjusted to equate the radiation force and a counterforce generated by an actuator calibrated against reference masses using direct current as the transfer variable. Improvements made during its one overhaul in 1988 have nearly halved its overall measurement uncertainty and extended the capabilities of the RFB to include measuring the output of ultrasonic systems with arbitrary pulse waveforms. PMID:27805084

  5. Xp11.2 Translocation renal cell carcinomas have a poorer prognosis than non-Xp11.2 translocation carcinomas in children and young adults: a meta-analysis.

    PubMed

    Qiu Rao; Bing Guan; Zhou, Xiao-jun

    2010-12-01

    Renal cell carcinomas (RCCs) in children and adolescents are much rarer than in adults. In this age group, Xp11.2 translocation RCCs were the most common subtype of pediatric RCCs. Information regarding the clinical behavior of pediatric RCCs remains controversial because of their relatively rare incidence. The authors aimed to perform a systematic review and meta-analysis to better define the biological features of pediatric RCCs. Eligible studies were identified through multiple search strategies. Studies were assessed for quality using the Jadad Quality Scale. Data were collected comparing overall survival (OS), disease-free survival (DFS), and stage in patients with TFE3 + pediatric RCCs and TFE3 - RCCs. A total of 4 studies were included for meta-analysis, and pooled odds ratios (ORs) with 95% confidence interval (CI) were calculated. The meta-analysis outcomes showed that TFE3 + pediatric RCCs were significantly associated with poorer outcomes (OS and DFS) and a higher stage (III/IV) than TFE3 - RCCs (pooled ORs for each group: 4.59 [95% CI = 1.46-14.42] for OS; 5.79 [95% CI = 1.85-18.16] for DFS; and 5.89 [95% CI = 2.23-15.52] for stage). This result was also confirmed by OS and DFS curves (P = .005 and P = .001). Xp11.2 translocation carcinomas appear to have a poorer prognosis than non-Xp11.2 translocation carcinomas in children and young adults.

  6. High-throughput machining using high average power ultrashort pulse lasers and ultrafast polygon scanner

    NASA Astrophysics Data System (ADS)

    Schille, Joerg; Schneider, Lutz; Streek, André; Kloetzer, Sascha; Loeschner, Udo

    2016-03-01

    In this paper, high-throughput ultrashort pulse laser machining is investigated on various industrial grade metals (Aluminium, Copper, Stainless steel) and Al2O3 ceramic at unprecedented processing speeds. This is achieved by using a high pulse repetition frequency picosecond laser with maximum average output power of 270 W in conjunction with a unique, in-house developed two-axis polygon scanner. Initially, different concepts of polygon scanners are engineered and tested to find out the optimal architecture for ultrafast and precision laser beam scanning. Remarkable 1,000 m/s scan speed is achieved on the substrate, and thanks to the resulting low pulse overlap, thermal accumulation and plasma absorption effects are avoided at up to 20 MHz pulse repetition frequencies. In order to identify optimum processing conditions for efficient high-average power laser machining, the depths of cavities produced under varied parameter settings are analyzed and, from the results obtained, the characteristic removal values are specified. The maximum removal rate is achieved as high as 27.8 mm3/min for Aluminium, 21.4 mm3/min for Copper, 15.3 mm3/min for Stainless steel and 129.1 mm3/min for Al2O3 when full available laser power is irradiated at optimum pulse repetition frequency.

  7. Pulse Detonation Rocket MHD Power Experiment

    NASA Technical Reports Server (NTRS)

    Litchford, Ron J.; Cook, Stephen (Technical Monitor)

    2002-01-01

    A pulse detonation research engine (MSFC (Marshall Space Flight Center) Model PDRE (Pulse Detonation Rocket Engine) G-2) has been developed for the purpose of examining integrated propulsion and magnetohydrodynamic power generation applications. The engine is based on a rectangular cross-section tube coupled to a converging-diverging nozzle, which is in turn attached to a segmented Faraday channel. As part of the shakedown testing activity, the pressure wave was interrogated along the length of the engine while running on hydrogen/oxygen propellants. Rapid transition to detonation wave propagation was insured through the use of a short Schelkin spiral near the head of the engine. The measured detonation wave velocities were in excess of 2500 m/s in agreement with the theoretical C-J velocity. The engine was first tested in a straight tube configuration without a nozzle, and the time resolved thrust was measured simultaneously with the head-end pressure. Similar measurements were made with the converging-diverging nozzle attached. The time correlation of the thrust and head-end pressure data was found to be excellent. The major purpose of the converging-diverging nozzle was to configure the engine for driving an MHD generator for the direct production of electrical power. Additional tests were therefore necessary in which seed (cesium-hydroxide dissolved in methanol) was directly injected into the engine as a spray. The exhaust plume was then interrogated with a microwave interferometer in an attempt to characterize the plasma conditions, and emission spectroscopy measurements were also acquired. Data reduction efforts indicate that the plasma exhaust is very highly ionized, although there is some uncertainty at this time as to the relative abundance of negative OH ions. The emission spectroscopy data provided some indication of the species in the exhaust as well as a measurement of temperature. A 24-electrode-pair segmented Faraday channel and 0.6 Tesla permanent

  8. Renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions: clinical experience and literature review.

    PubMed

    He, Jian; Chen, Xiancheng; Gan, Weidong; Zhu, Bin; Fan, Xiangshan; Guo, Hongqian; Jia, Ruipeng

    2015-01-01

    To analyze the clinicopathological features of renal cell carcinoma (RCC) associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 RCC) in our institution. We screened 983 RCC specimens. TFE3 immunohistochemical staining and FISH assay confirmed 22 Xp11.2 RCCs out of 65 suspicious cases. Clinicopathological and treatment outcomes of 22 patients were retrospectively analyzed. In total, 22 patients included 13 females and nine males with a mean age of 27 years. Ten patients showed gross hematuria. Treatments included surgeries, immunotherapy and molecular-targeted therapy. Seven cases were at stage III/IV and four cases had tumor thrombosis or distant metastasis. During a median follow-up of 34 months, 19 patients were alive while three died of distant metastasis. Xp11.2 RCC is rare and FISH proved a useful diagnostic tool. Surgical resection achieved favorable outcome for early disease. Adult patients at advanced stage had poorer outcomes even with postoperative adjuvant therapy.

  9. High power all-polarization-maintaining photonic crystal fiber monolithic femtosecond nonlinear chirped-pulse amplifier

    NASA Astrophysics Data System (ADS)

    Lv, Zhiguo; Yang, Zhi; Li, Feng; Yang, Xiaojun; Li, Qianglong; Zhang, Xin; Wang, Yishan; Zhao, Wei

    2018-03-01

    We report on an experimental study on fully fusion spliced high power all-polarization-maintaining Yb-doped photonic crystal fiber (PCF) femtosecond nonlinear chirped-pulse amplifier (CPA), which features large values of the positive third-order dispersion (TOD) superposed from the single-mode fiber stretcher (SMFs) and grating-pair compressor. Compensation of the TOD is realized by means of self-phase modulation (SPM) induced nonlinear phase shift during amplification. Up to 9.8 W of compressed average power at 275 kHz repetition rates with 36 μJ pulse energy and 495 fs pulse width has been obtained. To the best of our knowledge, this is the highest output power generated from the strictly all-fiber nonlinear CPA amplifier in femtosecond domain, which provides a possibility for the industrialized promotion and development of the high energy femtosecond fiber laser.

  10. Fiber optic cables for transmission of high-power laser pulses in spaceflight applications

    NASA Astrophysics Data System (ADS)

    Thomes, W. J.; Ott, M. N.; Chuska, R. F.; Switzer, R. C.; Blair, D. E.

    2017-11-01

    Lasers with high peak power pulses are commonly used in spaceflight missions for a wide range of applications, from LIDAR systems to optical communications. Due to the high optical power needed, the laser has to be located on the exterior of the satellite or coupled through a series of free space optics. This presents challenges for thermal management, radiation resistance, and mechanical design. Future applications will require multiple lasers located close together, which further complicates the design. Coupling the laser energy into a fiber optic cable allows the laser to be relocated to a more favorable position on the spacecraft. Typical fiber optic termination procedures are not sufficient for injection of these high-power laser pulses without catastrophic damage to the fiber endface. In the current study, we will review the causes of fiber damage during high-power injection and discuss our new manufacturing procedures that overcome these issues to permit fiber use with high reliability in these applications. We will also discuss the proper methods for launching the laser pulses into the fiber to avoid damage and how this is being implemented for current spaceflight missions.

  11. Fiber Optic Cables for Transmission of High-Power Laser Pulses in Spaceflight Applications

    NASA Technical Reports Server (NTRS)

    Thomes, W. J., Jr.; Ott, M. N.; Chuska, R. F.; Switzer, R. C.; Blair, D. E.

    2010-01-01

    Lasers with high peak power pulses are commonly used in spaceflight missions for a wide range of applications, from LIDAR systems to optical communications. Due to the high optical power needed, the laser has to be located on the exterior of the satellite or coupled through a series of free space optics. This presents challenges for thermal management, radiation resistance, and mechanical design. Future applications will require multiple lasers located close together, which further complicates the design. Coupling the laser energy into a fiber optic cable allows the laser to be relocated to a more favorable position on the spacecraft. Typical fiber optic termination procedures are not sufficient for injection of these high-power laser pulses without catastrophic damage to the fiber endface. In the current study, we will review the causes of fiber damage during high-power injection and discuss our new manufacturing procedures that overcome these issues to permit fiber use with high reliability in these applications. We will also discuss the proper methods for launching the laser pulses into the fiber to avoid damage and how this is being implemented for current spaceflight missions.

  12. Optimization of hybrid power system composed of SMES and flywheel MG for large pulsed load

    NASA Astrophysics Data System (ADS)

    Niiyama, K.; Yagai, T.; Tsuda, M.; Hamajima, T.

    2008-09-01

    A superconducting magnetic storage system (SMES) has some advantages such as rapid large power response and high storage efficiency which are superior to other energy storage systems. A flywheel motor generator (FWMG) has large scaled capacity and high reliability, and hence is broadly utilized for a large pulsed load, while it has comparatively low storage efficiency due to high mechanical loss compared with SMES. A fusion power plant such as International Thermo-Nuclear Experimental Reactor (ITER) requires a large and long pulsed load which causes a frequency deviation in a utility power system. In order to keep the frequency within an allowable deviation, we propose a hybrid power system for the pulsed load, which equips the SMES and the FWMG with the utility power system. We evaluate installation cost and frequency control performance of three power systems combined with energy storage devices; (i) SMES with the utility power, (ii) FWMG with the utility power, (iii) both SMES and FWMG with the utility power. The first power system has excellent frequency power control performance but its installation cost is high. The second system has inferior frequency control performance but its installation cost is the lowest. The third system has good frequency control performance and its installation cost is attained lower than the first power system by adjusting the ratio between SMES and FWMG.

  13. An approach for estimating acoustic power in a pulse tube cryocooler

    NASA Astrophysics Data System (ADS)

    Jiang, Xiao; Qiu, Limin; Duan, Chaoxiang; You, Xiaokuan; Zhi, Xiaoqin

    2017-10-01

    Acoustic power at the cold end of regenerator is the measure of gross cooling capacity for a pulse tube cryocooler (PTC), which cannot be measured directly. Conventionally, the acoustic power can only be derived from the measurement of velocity, pressure and their phase angle, which is still a challenge for an oscillating flow at cryogenic temperatures. A new method is proposed for estimating the acoustic power, which takes use of the easily measurable parameters, such as the pressure and temperature, instead of the velocity and phase angle between the pressure and velocity at cryogenic temperatures. The ratio of acoustic powers at the both ends of isothermal components, like regenerator, heat exchangers, can be conveniently evaluated by using the ratio of pressure amplitudes and the local temperatures. The ratio of acoustic powers at the both ends of adiabatic components, like transfer line and pulse tube, is obtained by using the ratio of pressure amplitudes. Accuracy of the approach for evaluating the acoustic power for the regenerator is analyzed by comparing the results with those from REGEN 3.3 and references. For the cold end temperature range of 40-80 K, the deviation is less than 5% if the phase angle at the cold end of regenerator is around -30°. The simple method benefits estimating the acoustic power and optimizing the PTC performance without interfering the cryogenic flow field.

  14. Switching power pulse system

    DOEpatents

    Aaland, Kristian

    1983-01-01

    A switching system for delivering pulses of power from a source (10) to a load (20) using a storage capacitor (C3) charged through a rectifier (D1, D2), and maintained charged to a reference voltage level by a transistor switch (Q1) and voltage comparator (12). A thyristor (22) is triggered to discharge the storage capacitor through a saturable reactor (18) and fractional turn saturable transformer (16) having a secondary to primary turn ratio N of n:l/n=n.sup.2. The saturable reactor (18) functions as a "soaker" while the thyristor reaches saturation, and then switches to a low impedance state. The saturable transformer functions as a switching transformer with high impedance while a load coupling capacitor (C4) charges, and then switches to a low impedance state to dump the charge of the storage capacitor (C3) into the load through the coupling capacitor (C4). The transformer is comprised of a multilayer core (26) having two secondary windings (28, 30) tightly wound and connected in parallel to add their output voltage and reduce output inductance, and a number of single turn windings connected in parallel at nodes (32, 34) for the primary winding, each single turn winding linking a different one of the layers of the multilayer core. The load may be comprised of a resistive beampipe (40) for a linear particle accelerator and capacitance of a pulse forming network (42). To hold off discharge of the capacitance until it is fully charged, a saturable core (44) is provided around the resistive beampipe (40) to isolate the beampipe from the capacitance (42) until it is fully charged.

  15. Renal carcinomas associated with Xp11.2 translocations: are CT findings suggestive of the diagnosis?

    PubMed

    He, J; Huan, Y; Qiao, Q; Zhang, J; Zhang, J S

    2014-01-01

    The purpose of the present study was to summarize the computed tomography (CT) features of renal carcinomas associated with Xp11.2 translocations, and determine whether the diagnosis can be reliably deduced from imaging findings. Radiological studies of six patients (aged from 9-29 years) with renal carcinoma associated with Xp11.2 translocations were retrospectively analysed. The tumours varied in size from 3.3-11 cm (mean 5.4 cm). Unenhanced CT and cortical, medullary, and pelvic-phase contrast-enhanced CT imaging was undertaken in all cases. Unenhanced CT revealed that tumours had a relatively increased radiodensity (4/6, ranged from 45-60 HU) and suggested the possibility of diffuse haemorrhage. Three of the six cases showed irregular and boundary calcification of the lesion. Contrast-enhanced CT showed relatively well demarcated tumours with heterogeneous enhancement (6/6). Prolonged enhancement of tumours might be a common sign (6/6) in Xp11.2 translocations. Three out of the six cases were combined with retroperitoneal lymph nodes metastasis. Renal carcinomas associated with Xp11.2 translocations should be considered, particularly in children and young patients, when the lesion has calcification and is hyper-dense on unenhanced CT, and has prolonged enhancement on contrast-enhanced images. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Novel pulsed switched power supply for a fast field cycling NMR spectrometer.

    PubMed

    Sousa, D M; Fernandes, P A L; Marques, G D; Ribeiro, A C; Sebastião, P J

    2004-01-01

    In this paper, we outline the operating principles of a pulsed switched power supply for a fast field-cycling nuclear magnetic resonance spectrometer. The power supply uses a variant of a four-quadrant chopper with a duty cycle that defines the average output current. With this topology only two semiconductors are necessary to drive hundreds of amperes with an output power of several kilowatts. The output current ripple has a well-defined shape that can be reduced to acceptable values by a careful design of the semiconductors' controlling circuits and drivers. A power supply prototype was tested with a home build air-core magnet operating with fields between 0 and 0.21 T. The system is computer controlled using pulse generator and data acquisition PC cards, and specific user-friendly home-developed software. A comparative proton relaxometry study in two well-known liquid crystal compounds 5CB and MBBA was performed to check the reproducibility of the T1 measurements.

  17. High-average-power 2 μm few-cycle optical parametric chirped pulse amplifier at 100 kHz repetition rate.

    PubMed

    Shamir, Yariv; Rothhardt, Jan; Hädrich, Steffen; Demmler, Stefan; Tschernajew, Maxim; Limpert, Jens; Tünnermann, Andreas

    2015-12-01

    Sources of long wavelengths few-cycle high repetition rate pulses are becoming increasingly important for a plethora of applications, e.g., in high-field physics. Here, we report on the realization of a tunable optical parametric chirped pulse amplifier at 100 kHz repetition rate. At a central wavelength of 2 μm, the system delivered 33 fs pulses and a 6 W average power corresponding to 60 μJ pulse energy with gigawatt-level peak powers. Idler absorption and its crystal heating is experimentally investigated for a BBO. Strategies for further power scaling to several tens of watts of average power are discussed.

  18. High-power picosecond pulse delivery through hollow core photonic band gap fibers

    NASA Astrophysics Data System (ADS)

    Michieletto, Mattia; Johansen, Mette M.; Lyngsø, Jens K.; Lægsgaard, Jesper; Bang, Ole; Alkeskjold, Thomas T.

    2016-03-01

    We demonstrated robust and bend insensitive fiber delivery of high power laser with diffraction limited beam quality for two different kinds of hollow core band gap fibers. The light source for this experiment consists of ytterbium-doped double clad fiber aeroGAIN-ROD-PM85 in a high power amplifier setup. It provided 22ps pulses with a maximum average power of 95W, 40MHz repetition rate at 1032nm (~2.4μJ pulse energy), with M2 <1.3. We determined the facet damage threshold for a 7-cells hollow core photonic bandgap fiber and showed up to 59W average power output for a 5 meters fiber. The damage threshold for a 19-cell hollow core photonic bandgap fiber exceeded the maximum power provided by the light source and up to 76W average output power was demonstrated for a 1m fiber. In both cases, no special attention was needed to mitigate bend sensitivity. The fibers were coiled on 8 centimeters radius spools and even lower bending radii were present. In addition, stimulated rotational Raman scattering arising from nitrogen molecules was measured through a 42m long 19 cell hollow core fiber.

  19. High power radiators of ultra-short electromagnetic quasi-unipolar pulses

    NASA Astrophysics Data System (ADS)

    Fedorov, V. M.; Ostashev, V. E.; Tarakanov, V. P.; Ul'yanov, A. V.

    2017-05-01

    Results of creation, operation, and diagnostics of the high power radiators for ultra-short length electromagnetic pulses (USEMPs) with a quasi-unipolar profile, which have been developed in our laboratory, are presented. The radiating module contains: the ultra-wideband (UWB) antenna array, the exciting high voltage pulse semiconductor generator (a pulser), the power source and the control unit. The principles of antenna array with a high efficiency aperture about 0.9 were developed using joint four TEM-horns with shielding electrodes in every TEM-horn. Sizes of the antenna apertures were (16-60) cm. The pulsers produced by “FID Technology” company had the following parameters: 50 Ohm connector impedance, unipolar pulses voltages (10-100) kV, the rise-time (0.04-0.15) ns, and the width (0.2-1) ns. The modules radiate the USEMPs of (0.1-10) GHz spectrum, their repetition rate is (1-100) kHz, and the effective potential is E*R = (20-400) kV, producing the peak E-field into the far-zone of R-distance. Parameters of the USEMP waves were measured by a calibrated sensor with the following characteristics: the sensitivity 0.32V/(kV/m), the rise-time 0.03 ns, the duration up to 7 ns. The measurements were in agreement with the simulation results, which were obtained using the 3-D code “KARAT”. The USEMP waves with amplitudes (1-10) kV/m and the pulse repetition rate (0.5-100) kHz were successfully used to examine various electronic devices for an electromagnetic immunity.

  20. Active cooling of pulse compression diffraction gratings for high energy, high average power ultrafast lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alessi, David A.; Rosso, Paul A.; Nguyen, Hoang T.

    Laser energy absorption and subsequent heat removal from diffraction gratings in chirped pulse compressors poses a significant challenge in high repetition rate, high peak power laser development. In order to understand the average power limitations, we have modeled the time-resolved thermo-mechanical properties of current and advanced diffraction gratings. We have also developed and demonstrated a technique of actively cooling Petawatt scale, gold compressor gratings to operate at 600W of average power - a 15x increase over the highest average power petawatt laser currently in operation. As a result, combining this technique with low absorption multilayer dielectric gratings developed in ourmore » group would enable pulse compressors for petawatt peak power lasers operating at average powers well above 40kW.« less

  1. Active cooling of pulse compression diffraction gratings for high energy, high average power ultrafast lasers

    DOE PAGES

    Alessi, David A.; Rosso, Paul A.; Nguyen, Hoang T.; ...

    2016-12-26

    Laser energy absorption and subsequent heat removal from diffraction gratings in chirped pulse compressors poses a significant challenge in high repetition rate, high peak power laser development. In order to understand the average power limitations, we have modeled the time-resolved thermo-mechanical properties of current and advanced diffraction gratings. We have also developed and demonstrated a technique of actively cooling Petawatt scale, gold compressor gratings to operate at 600W of average power - a 15x increase over the highest average power petawatt laser currently in operation. As a result, combining this technique with low absorption multilayer dielectric gratings developed in ourmore » group would enable pulse compressors for petawatt peak power lasers operating at average powers well above 40kW.« less

  2. Detection of cerebral ischemia using the power spectrum of the pulse wave measured by near-infrared spectroscopy.

    PubMed

    Ebihara, Akira; Tanaka, Yuichi; Konno, Takehiko; Kawasaki, Shingo; Fujiwara, Michiyuki; Watanabe, Eiju

    2013-10-01

    The diagnosis and medical treatment of cerebral ischemia are becoming more important due to the increase in the prevalence of cerebrovascular disease. However, conventional methods of evaluating cerebral perfusion have several drawbacks: they are invasive, require physical restraint, and the equipment is not portable, which makes repeated measurements at the bedside difficult. An alternative method is developed using near-infrared spectroscopy (NIRS). NIRS signals are measured at 44 positions (22 on each side) on the fronto-temporal areas in 20 patients with cerebral ischemia. In order to extract the pulse-wave component, the raw total hemoglobin data recorded from each position are band-pass filtered (0.8 to 2.0 Hz) and subjected to a fast Fourier transform to obtain the power spectrum of the pulse wave. The ischemic region is determined by single-photon emission computed tomography. The pulse-wave power in the ischemic region is compared with that in the symmetrical region on the contralateral side. In 17 cases (85%), the pulse-wave power on the ischemic side is significantly lower than that on the contralateral side, which indicates that the transmission of the pulse wave is attenuated in the region with reduced blood flow. Pulse-wave power might be useful as a noninvasive marker of cerebral ischemia.

  3. High-power picosecond pulses by SPM-induced spectral compression in a fiber amplifier

    NASA Astrophysics Data System (ADS)

    Schreiber, T.; Liem, A.; Roeser, F.; Zellmer, H.; Tuennermann, A.; Limpert, J.; Deguil-Robin, N.; Manek-Honninger, I.; Salin, F.; Courjaud, A.; Honninger, C.; Mottay, E.

    2005-04-01

    The fiber based generation of nearly transform-limited 10-ps pulses with 200 kW peak power (97 W average power) based on SPM-induced spectral compression is reported. Efficient second harmonic generation applying this source is also discussed.

  4. Simultaneous Wireless Power Transfer and Data Communication Using Synchronous Pulse-Controlled Load Modulation.

    PubMed

    Mao, Shitong; Wang, Hao; Zhu, Chunbo; Mao, Zhi-Hong; Sun, Mingui

    2017-10-01

    Wireless Power Transfer (WPT) and wireless data communication are both important problems of research with various applications, especially in medicine. However, these two problems are usually studied separately. In this work, we present a joint study of both problems. Most medical electronic devices, such as smart implants, must have both a power supply to allow continuous operation and a communication link to pass information. Traditionally, separate wireless channels for power transfer and communication are utilized, which complicate the system structure, increase power consumption and make device miniaturization difficult. A more effective approach is to use a single wireless link with both functions of delivering power and passing information. We present a design of such a wireless link in which power and data travel in opposite directions. In order to aggressively miniaturize the implant and reduce power consumption, we eliminate the traditional multi-bit Analog-to-Digital Converter (ADC), digital memory and data transmission circuits all together. Instead, we use a pulse stream, which is obtained from the original biological signal, by a sigma-delta converter and an edge detector, to alter the load properties of the WPT channel. The resulting WPT signal is synchronized with the load changes therefore requiring no memory elements to record inter-pulse intervals. We take advantage of the high sensitivity of the resonant WPT to the load change, and the system dynamic response is used to transfer each pulse. The transient time of the WPT system is analyzed using the coupling mode theory (CMT). Our experimental results show that the memoryless approach works well for both power delivery and data transmission, providing a new wireless platform for the design of future miniaturized medical implants.

  5. Westinghouse programs in pulsed homopolar power supplies

    NASA Technical Reports Server (NTRS)

    Litz, D. C.; Mullan, E.

    1984-01-01

    This document details Westinghouse's ongoing study of homopolar machines since 1929 with the major effort occurring in the early 1970's to the present. The effort has enabled Westinghouse to develop expertise in the technology required for the design, fabrication and testing of such machines. This includes electrical design, electromagnetic analysis, current collection, mechanical design, advanced cooling, stress analysis, transient rotor performance, bearing analysis and seal technology. Westinghouse is using this capability to explore the use of homopolar machines as pulsed power supplies for future systems in both military and commercial applications.

  6. Nucleotide Excision Repair Proteins Rapidly Accumulate but Fail to Persist in Human XP-E (DDB2 Mutant) Cells

    PubMed Central

    Oh, Kyu-Seon; Imoto, Kyoko; Emmert, Steffen; Tamura, Deborah; DiGiovanna, John J.; Kraemer, Kenneth. H.

    2011-01-01

    The XP-E DNA damage binding protein (DDB2) is involved in early recognition of global genome DNA damage during DNA nucleotide excision repair (NER). We found that skin fibroblasts from 4 newly reported XP-E patients with numerous skin cancers and DDB2 mutations had slow repair of 6-4 photoproducts (6-4PP) and markedly reduced repair of cyclobutane pyrimidine dimers (CPD). NER proteins (XPC, XPB, XPG, XPA, and XPF) co-localized to CPD and 6-4PP positive regions immediately (< 0.1h) after localized UV irradiation in cells from the XP-E patients and normal controls. While these proteins persist in normal cells, surprisingly, within 0.5h these repair proteins were no longer detectable at the sites of DNA damage in XP-E cells. Our results indicate that DDB2 is not required for the rapid recruitment of NER proteins to sites of UV photoproducts or for partial repair of 6-4PP but is essential for normal persistence of these proteins for CPD photoproduct removal. PMID:21388382

  7. Observation of frequency up-conversion in the propagation of a high-power microwave pulse in a self-generated plasma

    NASA Technical Reports Server (NTRS)

    Kuo, S. P.; Zhang, Y. S.; Ren, A.

    1990-01-01

    A chamber experiment is conducted to study the propagation of a high-power microwave pulse. The results show that the pulse is experiencing frequency up-shift while ionizing the background air if the initial carrier frequency of the pulse is higher than the electron plasma frequency at the incident boundary. Such a frequency autoconversion process may lead to reflectionless propagation of a high-power microwave pulse through the atmosphere.

  8. High-power, highly stable KrF laser with a 4-kHz pulse repetition rate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borisov, V M; El'tsov, A V; Khristoforov, O B

    2015-08-31

    An electric-discharge KrF laser (248 nm) with an average output power of 300 W is developed and studied. A number of new design features are related to the use of a laser chamber based on an Al{sub 2}O{sub 3} ceramic tube. A high power and pulse repetition rate are achieved by using a volume discharge with lateral preionisation by the UV radiation of a creeping discharge in the form of a homogeneous plasma sheet on the surface of a plane sapphire plate. Various generators for pumping the laser are studied. The maximum laser efficiency is 3.1%, the maximum laser energymore » is 160 mJ pulse{sup -1}, and the pulse duration at half maximum is 7.5 ns. In the case of long-term operation at a pulse repetition rate of 4 kHz and an output power of 300 W, high stability of laser output energy (σ ≤ 0.7%) is achieved using an all-solid-state pump system. (lasers)« less

  9. Hybrid Er/Yb fibre laser system for generating few-cycle 1.6 to 2.0 {mu}m pulses optically synchronised with high-power pulses near 1 {mu}m

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrianov, A V; Anashkina, E A; Murav'ev, S V

    2013-03-31

    This paper presents the concept of fibre laser system design for generating optically synchronised femtosecond pulses at two, greatly differing wavelengths and reports experimental and numerical simulation studies of nonlinear conversion of femtosecond pulses at 1.5 {mu}m wavelength in a dispersion-shifted fibre, with the generation of synchronised pulses in the ranges 1.6 - 2 and 1 - 1.1 {mu}m. We describe a three-stage high-power fibre amplifier of femtosecond pulses at 1 {mu}m and a hybrid Er/Yb fibre laser system that has enabled the generation of 12 fs pulses with a centre wavelength of 1.7 {mu}m, synchronised with high-power (microjoule level)more » 250 fs pulses at 1.03 {mu}m. (extreme light fields and their applications)« less

  10. Kilohertz Pulse Repetition Frequency Slab Ti:sapphire Lasers with High Average Power (10 W)

    NASA Astrophysics Data System (ADS)

    Wadsworth, William J.; Coutts, David W.; Webb, Colin E.

    1999-11-01

    High-average-power broadband 780-nm slab Ti:sapphire lasers, pumped by a kilohertz pulse repetition frequency copper vapor laser (CVL), were demonstrated. These lasers are designed for damage-free power scaling when pumped by CVL s configured for maximum output power (of order 100 W) but with poor beam quality ( M 2 300 ). A simple Brewster-angled slab laser side pumped by a CVL produced 10-W average power (1.25-mJ pulses at 8 kHz) with 4.2-ns FWHM pulse duration at an absolute efficiency of 15% (68-W pump power). Thermal lensing in the Brewster slab laser resulted in multitransverse mode output, and pump absorption was limited to 72% by the maximum doping level for commercially available Ti:sapphire (0.25%). A slab laser with a multiply folded zigzag path was therefore designed and implemented that produced high-beam-quality (TEM 00 -mode) output when operated with cryogenic cooling and provided a longer absorption path for the pump. Excessive scattering of the Ti:sapphire beam at the crystal surfaces limited the efficiency of operation for the zigzag laser, but fluorescence diagnostic techniques, gain measurement, and modeling suggest that efficient power extraction ( 15 W TEM 00 , 23% efficiency) from this laser would be possible for crystals with an optical quality surface polish.

  11. Ultra-powerful compact amplifiers for short laser pulses

    NASA Astrophysics Data System (ADS)

    Malkin, Vladimir

    1999-11-01

    Laser compressors-amplifiers more powerful and compact than ones based on the currently most advanced chirped pulse amplification technique must handle ultrahigh laser intensities. The medium capable of bearing those is plasma. An interesting kinetic regime of short laser pulse amplification by Compton backscattering of counterpropagating laser pump in plasma, akin to superradiant amplification in free-electron lasers, has been proposed recently (Shvets G., Fisch N. J., Pukhov A., and Meyer-ter-Vehn J., Phys. Rev. Lett., v.81, 4879 (1998)). However, the conversion efficiency of pump energy into a short pulse appears to be higher in a transient Raman backscattering regime (Malkin V. M., Shvets G. and Fisch N. J., Phys. Rev. Lett., v.82, 4448 (1999)), where the integrity of the three-wave interaction is maintained. In this regime the pump is completely depleted through the full nonlinear stage of the interaction, so that unwanted Raman and modulational instabilities limit just the amplification time, while the efficiency is kept about 100%. For instance, a 2*10^14 W/cm^2, 1 μm-wavelength laser pump can be compressed within 5 mm length, which is less than the length for filamentation instabilities to develop, to a 30--40 fsec pulse with fluence 6 kJ/cm^2. Such an output pulse is a thousand times shorter and a million time more intensive than outputs of conventional Raman amplifiers operating in a stationary regime. Yet larger amplification distances and output energies can be achieved by suppressing filamentation instabilities. It appears (Malkin V. M., Shvets G. and Fisch N. J., Submitted to Phys. Rev. Lett.) that appropriate detuning of the resonance (by plasma density gradient or/and chirping the pump laser) suppresses the Raman near-forward scattering instability of the pumped pulse, as well as the pump Raman backscattering instability to noise, while the high efficiency of the amplification still persists. The respective new class of transient amplification

  12. Generation of spectrally stable continuous-wave emission and ns pulses with a peak power of 4 W using a distributed Bragg reflector laser and a ridge-waveguide power amplifier.

    PubMed

    Klehr, A; Wenzel, H; Fricke, J; Bugge, F; Erbert, G

    2014-10-06

    We have developed a diode-laser based master oscillator power amplifier (MOPA) light source which emits high-power spectrally stabilized and nearly-diffraction limited optical pulses in the nanoseconds range as required by many applications. The MOPA consists of a distributed Bragg reflector (DBR) laser as master oscillator driven by a constant current and a ridge waveguide power amplifier (PA) which can be driven by a constant current (DC) or by rectangular current pulses with a width of 5 ns at a repetition frequency of 200 kHz. Under pulsed operation the amplifier acts as an optical gate, converting the CW input beam emitted by the DBR laser into a train of short amplified optical pulses. With this experimental MOPA arrangement no relaxation oscillations occur. A continuous wave power of 1 W under DC injection and a pulse power of 4 W under pulsed operation are reached. For both operational modes the optical spectrum of the emission of the amplifier exhibits a peak at a constant wavelength of 973.5 nm with a spectral width < 10 pm.

  13. Ultrasonographic Findings of Renal Cell Carcinomas Associated with Xp11.2 Translocation/TFE3 Gene Fusion.

    PubMed

    Ling, Wenwu; Ma, Xuelei; Luo, Yan; Chen, Linyan; Wang, Huiyao; Wang, Xiaoling; Chen, Ni; Zeng, Hao; Li, Yongzhong; Cai, Diming

    2017-01-01

    This study was to investigate the features of renal carcinomas associated with Xp11.2 translocations/TFE3 gene fusions (Xp11.2-RCC) on conventional ultrasound (US) and contrast-enhanced ultrasound (CEUS). US and CEUS features of twenty-two cases with histopathologically proven Xp11.2-RCC were retrospectively reviewed. 22 patients (11 males, 11 females) were included in this study, with a mean age of 28.3 ± 20.4 years. Eight tumors (36.3%, 8/22) were in left kidney, and 14 tumors (63.7%, 14/22) were in right kidney. All tumors (100%, 22/22) were mixed echogenicity type. 13 tumors (59.1%, 13/22) presented small dotted calcifications. The boundary of 14 tumors (63.6%, 14/22) was sharp and the other 8 tumors' (36.4%, 8/22) boundary was blurry. By CEUS, in early phase, the solid element of all tumors showed obvious enhancement. In delayed phase, 13 tumors showed hypoenhancement, seven tumors showed isoenhancement, and 2 tumors showed hyperenhancement. There were irregular nonenhancement areas in all tumors inside. By US and CEUS, when children and adolescents were found to have hyperechoic mixed tumor in kidney with sharp margin and calcification, and the tumors showed obvious enhancement and hypoenhancement with irregular nonenhancement areas in the tumor in early phase and delayed phase, respectively, Xp11.2-RCC should be suspected.

  14. Hydrodynamic and material properties experiments using pulsed power techniques

    NASA Astrophysics Data System (ADS)

    Reinovsky, R. E.; Trainor, R. J.

    2000-04-01

    Within the last five years, a new approach to the exploration of dynamic material properties and advanced hydrodynamics at extreme conditions has joined the traditional techniques of high velocity guns and explosives. This new application uses electromagnetic energy to accelerate solid density material to produce shocks in a cylindrical target. The principal tool for producing high energy density environments is the high precision, magnetically imploded, near-solid density cylindrical liner. The most attractive pulsed power system for driving such experiments is an ultrahigh current, low impedance, microsecond time scale source that is economical both to build and to operate. Two families of pulsed power systems can be applied to drive such experiments. The 25-MJ Atlas capacitor bank system currently under construction at Los Alamos is the first system of its scale specifically designed to drive high precision solid liners. Delivering 30 MA, Atlas will provide liner velocities 12-15 km/sec and kinetic energies of 1-2 MJ/cm with extensive diagnostics and excellent reproducibility. Explosive flux compressor technology provides access to currents exceeding 100 MA producing liner velocities above 25 km/sec and kinetic energies of 5-20 MJ/cm in single shot operations

  15. 500 MW peak power degenerated optical parametric amplifier delivering 52 fs pulses at 97 kHz repetition rate.

    PubMed

    Rothhardt, J; Hädrich, S; Röser, F; Limpert, J; Tünnermann, A

    2008-06-09

    We present a high peak power degenerated parametric amplifier operating at 1030 nm and 97 kHz repetition rate. Pulses of a state-of-the art fiber chirped-pulse amplification (FCPA) system with 840 fs pulse duration and 410 microJ pulse energy are used as pump and seed source for a two stage optical parametric amplifier. Additional spectral broadening of the seed signal in a photonic crystal fiber creates enough bandwidth for ultrashort pulse generation. Subsequent amplification of the broadband seed signal in two 1 mm BBO crystals results in 41 microJ output pulse energy. Compression in a SF 11 prism compressor yields 37 microJ pulses as short as 52 fs. Thus, pulse shortening of more than one order of magnitude is achieved. Further scaling in terms of average power and pulse energy seems possible and will be discussed, since both concepts involved, the fiber laser and the parametric amplifier have the reputation to be immune against thermo-optical effects.

  16. Sub-MW peak power diffraction-limited chirped-pulse monolithic Yb-doped tapered fiber amplifier.

    PubMed

    Bobkov, Konstantin; Andrianov, Alexey; Koptev, Maxim; Muravyev, Sergey; Levchenko, Andrei; Velmiskin, Vladimir; Aleshkina, Svetlana; Semjonov, Sergey; Lipatov, Denis; Guryanov, Alexey; Kim, Arkady; Likhachev, Mikhail

    2017-10-30

    We demonstrate a novel amplification regime in a counter-pumped, relatively long (2 meters), large mode area, highly Yb-doped and polarization-maintaining tapered fiber, which offers a high peak power directly from the amplifier. The main feature of this regime is that the amplifying signal propagates through a thin part of the tapered fiber without amplification and experiences an extremely high gain in the thick part of the tapered fiber, where most of the pump power is absorbed. In this regime, we have demonstrated 8 ps pulse amplification to a peak power of up to 0.76 MW, which is limited by appearance of stimulated Raman scattering. In the same regime, 28 ps chirped pulses are amplified to a peak power of 0.35 MW directly from the amplifier and then compressed with 70% efficiency to 315 ± 10 fs, corresponding to an estimated peak power of 22 MW.

  17. Computed tomography and magnetic resonance imaging of adult renal cell carcinoma associated with Xp11.2 translocation.

    PubMed

    Dang, Trien T; Ziv, Etay; Weinstein, Stefanie; Meng, Maxwell V; Wang, Zhen; Coakley, Fergus V

    2012-01-01

    This study aimed to report the computed tomography (CT) and magnetic resonance imaging (MRI) findings of renal cell carcinoma associated with Xp11.2 translocation in adults. We retrospectively identified 9 adults with renal cell carcinoma associated with Xp11.2 translocation who underwent baseline cross-sectional imaging with CT (n = 9) or MRI (n = 3). All available clinical, imaging, and histopathological records were reviewed. Mean patient age was 24 years (range, 18-45 years). Eight of 9 cancers demonstrated imaging findings of hemorrhage or necrosis (n = 3), advanced stage disease (n = 2), or both (n = 3) at CT or MRI. The possibility of renal cell carcinoma associated with Xp11.2 translocation should be considered for a renal mass seen in a patient 45 years or younger, which demonstrates hemorrhage or necrosis or advanced stage disease at CT or MRI.

  18. Coordinated Research Program in Pulsed Power Physics.

    DTIC Science & Technology

    1985-12-20

    8217). Stale. and ZIP Code) 10 SOURCE OF FUNDING NOS. PROGRAM PROJECT TASK WORK UNIT ELE ME NT NO. NO. NO. No. 11.?ILE.ic.ecufC~sjf~aton 1 c 61102F 2301 A7 12...SYMBOLI lncludr Arra Code) 5" Major B. Smith j202/767-4908 AFOSR/NP FORM 1473. E3 APR EDITION OF I..AN 73 IS OBeCLETE Unclassified SEC A17 C! ww...fields at localized points in pulsed power systems*. In addition, as in previous years, new projects will be added as new ideas are generated. Funds for

  19. Advances in long pulse operation at high radio frequency power in Tore Supra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goniche, M.; Dumont, R.; Bourdelle, C.

    2014-06-15

    The lower hybrid current drive (LHCD) system of Tore Supra has been upgraded for long pulse operation at higher power (7–8 MW). The two launchers have coupled on plasma 3.8 MW and 2.7 MW separately. This new power capability allows extending the operational domain of Tore Supra for long pulses at higher current and density. 38 long (20 s –155 s) discharges with very low loop voltage (V{sub L} = 30-60 mV) were performed with combined LHCD (5-5.7 MW) and ICRH (1–3 MW) powers, with up to 1 GJ of injected energy. Higher LHCD efficiency, with respect to the previous long discharges, is reported. MHD stability of these discharges ismore » very sensitive to the LHCD power and parallel wave index, in particular in the preforming phase. For theses evanescent loop voltage plasmas, the ICRH power, in excess of 1 MW, is found to have a beneficial effect on the MHD stability.« less

  20. High Energy Density Capacitors for Pulsed Power Applications

    DTIC Science & Technology

    2009-07-01

    As a result of this effort, the US Military has access to capacitors that are about a third the size and half the cost of the capacitors that were...resistor in terms of shock and vibration, mounting requirements, total volume, system reliability, and cost . All of these parameters were improved...it t tipo ymer m qua y an capac or cons ruc on. Energy Density of 10,000 Shot High Efficiency Pulse Power Capacitors The primary driver was 1 5

  1. [Dependence of anti-inflammatory effects of high peak-power pulsed electromagnetic radiation of extremely high frequency on exposure parameters].

    PubMed

    Gapeev, A B; Mikhaĭlik, E N; Rubanik, A V; Cheremis, N K

    2007-01-01

    A pronounced anti-inflammatory effect of high peak-power pulsed electromagnetic radiation of extremely high frequency was shown for the first time in a model of zymosan-induced footpad edema in mice. Exposure to radiation of specific parameters (35, 27 GHz, peak power 20 kW, pulse widths 400-600 ns, pulse repetition frequency 5-500 Hz) decreased the exudative edema and local hyperthermia by 20% compared to the control. The kinetics and the magnitude of the anti-inflammatory effect were comparable with those induced by sodium diclofenac at a dose of 3 mg/kg. It was found that the anti-inflammatory effect linearly increased with increasing pulse width at a fixed pulse repetition frequency and had threshold dependence on the average incident power density of the radiation at a fixed pulse width. When animals were whole-body exposed in the far-field zone of radiator, the optimal exposure duration was 20 min. Increasing the average incident power density upon local exposure of the inflamed paw accelerated both the development of the anti-inflammatory effect and the reactivation time. The results obtained will undoubtedly be of great importance in the hygienic standardization of pulsed electromagnetic radiation and in further studies of the mechanisms of its biological action.

  2. A powerful graphical pulse sequence programming tool for magnetic resonance imaging.

    PubMed

    Jie, Shen; Ying, Liu; Jianqi, Li; Gengying, Li

    2005-12-01

    A powerful graphical pulse sequence programming tool has been designed for creating magnetic resonance imaging (MRI) applications. It allows rapid development of pulse sequences in graphical mode (allowing for the visualization of sequences), and consists of three modules which include a graphical sequence editor, a parameter management module and a sequence compiler. Its key features are ease to use, flexibility and hardware independence. When graphic elements are combined with a certain text expressions, the graphical pulse sequence programming is as flexible as text-based programming tool. In addition, a hardware-independent design is implemented by using the strategy of two step compilations. To demonstrate the flexibility and the capability of this graphical sequence programming tool, a multi-slice fast spin echo experiment is performed on our home-made 0.3 T permanent magnet MRI system.

  3. High-intensity focused ultrasound for ex vivo kidney tissue ablation: influence of generator power and pulse duration.

    PubMed

    Häcker, Axel; Köhrmann, Kai Uwe; Knoll, Thomas; Langbein, Sigrun; Steidler, Annette; Kraut, Oliver; Marlinghaus, Ernst; Alken, Peter; Michel, Maurice Stephan

    2004-11-01

    The therapeutic application of noninvasive tissue ablation by high-intensity focused ultrasound (HIFU) requires precise physical definition of the focal size and determination of control parameters. The objective of this study was to measure the extent of ex-vivo porcine kidney tissue ablation at variable generator parameters and to identify parameters to control lesion size. The ultrasound waves generated by a cylindrical piezoceramic element (1.04 MHz) were focused at a depth of 100 mm using a parabolic reflector (diameter 100 mm). A needle hydrophone was used to measure the field distribution of the sound pressure. The morphology and extent of tissue necrosis were examined at generator powers of up to 400 W (P(el)) and single pulse durations of as long as 8 seconds. The two-dimensional field distribution resulted in an approximately ellipsoidal focus of 32 x 4 mm (-6 dB). A sharp demarcation between coagulation necrosis and intact tissue was observed. Lesion size was controlled by both the variation of generator power and the pulse duration. At a constant pulse duration of 2 seconds, a generator power of 100 W remained below the threshold doses for inducing a reproducible lesion. An increase in power to as high as 400 W induced lesions with average dimensions of as much as 11.2 x 3 mm. At constant total energy (generator power x pulse duration), lesion size increased at higher generator power. This ultrasound generator can induce defined and reproducible necrosis in ex-vivo kidney tissue. Lesion size can be controlled by adjusting the generator power and pulse duration. Generator power, in particular, turned out to be a suitable control parameter for obtaining a lesion of a defined size.

  4. High power long pulse microwave generation from a metamaterial structure with reverse symmetry

    NASA Astrophysics Data System (ADS)

    Lu, Xueying; Stephens, Jacob C.; Mastovsky, Ivan; Shapiro, Michael A.; Temkin, Richard J.

    2018-02-01

    Experimental operation of a high power microwave source with a metamaterial (MTM) structure is reported at power levels to 2.9 MW at 2.4 GHz in full 1 μs pulses. The MTM structure is formed by a waveguide that is below cutoff for TM modes. The waveguide is loaded by two axial copper plates machined with complementary split ring resonators, allowing two backward wave modes to propagate in the S-Band. A pulsed electron beam of up to 490 kV, 84 A travels down the center of the waveguide, midway between the plates. The electron beam is generated by a Pierce gun and is focused by a lens into a solenoidal magnetic field. The MTM plates are mechanically identical but are placed in the waveguide with reverse symmetry. Theory indicates that both Cherenkov and Cherenkov-cyclotron beam-wave interactions can occur. High power microwave generation was studied by varying the operating parameters over a wide range, including the electron beam voltage, the lens magnetic field, and the solenoidal field. Frequency tuning with a magnetic field and beam voltage was studied to discriminate between operation in the Cherenkov mode and the Cherenkov-cyclotron mode. Both modes were observed, but pulses above 1 MW of output power were only seen in the Cherenkov-cyclotron mode. A pair of steering coils was installed prior to the interaction space to initiate the cyclotron motion of the electron beam and thus encourage the Cherenkov-cyclotron high power mode. This successfully increased the output power from 2.5 MW to 2.9 MW (450 kV, 74 A, 9% efficiency).

  5. Higher-order power harmonics of pulsed electrical stimulation modulates corticospinal contribution of peripheral nerve stimulation.

    PubMed

    Chen, Chiun-Fan; Bikson, Marom; Chou, Li-Wei; Shan, Chunlei; Khadka, Niranjan; Chen, Wen-Shiang; Fregni, Felipe

    2017-03-03

    It is well established that electrical-stimulation frequency is crucial to determining the scale of induced neuromodulation, particularly when attempting to modulate corticospinal excitability. However, the modulatory effects of stimulation frequency are not only determined by its absolute value but also by other parameters such as power at harmonics. The stimulus pulse shape further influences parameters such as excitation threshold and fiber selectivity. The explicit role of the power in these harmonics in determining the outcome of stimulation has not previously been analyzed. In this study, we adopted an animal model of peripheral electrical stimulation that includes an amplitude-adapted pulse train which induces force enhancements with a corticospinal contribution. We report that the electrical-stimulation-induced force enhancements were correlated with the amplitude of stimulation power harmonics during the amplitude-adapted pulse train. In an exploratory analysis, different levels of correlation were observed between force enhancement and power harmonics of 20-80 Hz (r = 0.4247, p = 0.0243), 100-180 Hz (r = 0.5894, p = 0.0001), 200-280 Hz (r = 0.7002, p < 0.0001), 300-380 Hz (r = 0.7449, p < 0.0001), 400-480 Hz (r = 0.7906, p < 0.0001), 500-600 Hz (r = 0.7717, p < 0.0001), indicating a trend of increasing correlation, specifically at higher order frequency power harmonics. This is a pilot, but important first demonstration that power at high order harmonics in the frequency spectrum of electrical stimulation pulses may contribute to neuromodulation, thus warrant explicit attention in therapy design and analysis.

  6. Pulsed Magnetic Field Driven Gas Core Reactors for Space Power & Propulsion Applications

    NASA Technical Reports Server (NTRS)

    Anghaie, Samim; Smith, Blair; Knight, Travis; Butler, Carey

    2003-01-01

    The present results indicated that: 1. A pulsed magnetic driven fission power concept, PMD-GCR is developed for closed (NER) and semi-open (NTR) operations. 2. In power mode, power is generated at alpha less than 1 for power levels of hundreds of KW or higher 3. IN semi open NTR mode, PMD-GCR generates thrust at I(sub sp) approx. 5,000 s and jet power approx. 5KW/Kg. 4. PMD-GCR is highly subcritical and is actively driven to critically. 5. Parallel path with fusion R&D needs in many areas including magnet and plasma.

  7. Investigation of Ion Beam Production and Acceleration Using Linear Electron Beams and a Pulse Powered Plasma Focus.

    DTIC Science & Technology

    1984-03-01

    POWERED PLASMA FOCUS Contract No. AFOSR-83-0145 PROGRESS REPORT For the Period April 1, 1983 through March 31, 1984 Submitted to Air Force Office of...AND ACCELERATION USING LINEAR ELECTRON BEAMS AND A PULSE POWERED PLASMA FOCUS Contract No. AFOSR-83-0145 PROGRESS REPORT For the Period April 1, 1983...Acceleration Using Linear Electron Beams and a Pulse Powered Plasma Focus " 01 €,G APRIL 1, 1983 THROUGH MRCH 31, 1984 A. Collective Acceleration and Related

  8. Ultrasonographic Findings of Renal Cell Carcinomas Associated with Xp11.2 Translocation/TFE3 Gene Fusion

    PubMed Central

    Zeng, Hao

    2017-01-01

    Objective This study was to investigate the features of renal carcinomas associated with Xp11.2 translocations/TFE3 gene fusions (Xp11.2-RCC) on conventional ultrasound (US) and contrast-enhanced ultrasound (CEUS). Methods US and CEUS features of twenty-two cases with histopathologically proven Xp11.2-RCC were retrospectively reviewed. Results 22 patients (11 males, 11 females) were included in this study, with a mean age of 28.3 ± 20.4 years. Eight tumors (36.3%, 8/22) were in left kidney, and 14 tumors (63.7%, 14/22) were in right kidney. All tumors (100%, 22/22) were mixed echogenicity type. 13 tumors (59.1%, 13/22) presented small dotted calcifications. The boundary of 14 tumors (63.6%, 14/22) was sharp and the other 8 tumors' (36.4%, 8/22) boundary was blurry. By CEUS, in early phase, the solid element of all tumors showed obvious enhancement. In delayed phase, 13 tumors showed hypoenhancement, seven tumors showed isoenhancement, and 2 tumors showed hyperenhancement. There were irregular nonenhancement areas in all tumors inside. Conclusions By US and CEUS, when children and adolescents were found to have hyperechoic mixed tumor in kidney with sharp margin and calcification, and the tumors showed obvious enhancement and hypoenhancement with irregular nonenhancement areas in the tumor in early phase and delayed phase, respectively, Xp11.2-RCC should be suspected. PMID:29333109

  9. Improving Reliability of High Power Quasi-CW Laser Diode Arrays Operating in Long Pulse Mode

    NASA Technical Reports Server (NTRS)

    Amzajerdian, Farzin; Meadows, Byron L.; Barnes, Bruce W.; Lockard, George E.; Singh, Upendra N.; Kavaya, Michael J.; Baker, Nathaniel R.

    2006-01-01

    Operating high power laser diode arrays in long pulse regime of about 1 msec, which is required for pumping 2-micron thulium and holmium-based lasers, greatly limits their useful lifetime. This paper describes performance of laser diode arrays operating in long pulse mode and presents experimental data of the active region temperature and pulse-to-pulse thermal cycling that are the primary cause of their premature failure and rapid degradation. This paper will then offer a viable approach for determining the optimum design and operational parameters leading to the maximum attainable lifetime.

  10. The target material influence on the current pulse during high power pulsed magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Moens, Filip; Konstantinidis, Stéphanos; Depla, Diederik

    2017-10-01

    The current-time characteristic during high power pulsed magnetron sputtering is measured under identical conditions for seventeen different target materials. Based on physical processes such as gas rarefaction, ion-induced electron emission, and electron impact ionization, two test parameters were derived that significantly correlate with specific features of the current-time characteristic: i) the peak current is correlated to the momentum transfer between the sputtered material and the argon gas, ii) while the observed current plateau after the peak is connected to the metal ionization rate.

  11. Continuous Wave Potassium Titanyl Phosphate Laser Treatment is Safe and Effective for Xanthelasma Palpebrarum.

    PubMed

    Greijmans, Ellen; Luiting-Welkenhuyzen, Hedwig; Luijks, Harriet; Bovenschen, H Jorn

    2016-07-01

    Although not an accepted standard treatment, the 532-nm continuous wave potassium titanyl phosphate (CW-KTP) laser might be a powerful device to treat xanthelasma palpebrarum (XP). To determine the safety and efficacy of CW-KTP laser treatment for XP. Between January 2013 and January 2015, 30 consecutive patients with XP were treated with a 532-nm CW-KTP laser (spot size: 0.9 mm, power: 5.0 W, fluence: 36-38 J/cm, pulse width: 46 milliseconds, frequency: 2.0 Hz, passes per session: 3). In a retrospective study design, safety and efficacy data were collected and analyzed. Overall, 29/30 (97%) of patients had an excellent cosmetical result. Downtime was 1 week with crusted lesions. Although slight hypopigmentation was common, only 1/30 (3%) patients had hypopigmentation that was more than expected. Recurrences (13/30; 43%) were frequent, so that yearly maintenance therapy was warranted. No major side effects were noticed. Continuous wave KTP laser therapy is safe and highly effective for XP, although regular follow-up treatments are often necessary to maintain the achieved cosmetic results.

  12. Effect of ProTaper Gold, Self-Adjusting File, and XP-endo Shaper Instruments on Dentinal Microcrack Formation: A Micro-computed Tomographic Study.

    PubMed

    Bayram, H Melike; Bayram, Emre; Ocak, Mert; Uygun, Ahmet Demirhan; Celik, Hakan Hamdi

    2017-07-01

    The aim of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with ProTaper Universal (PTU; Dentsply Tulsa Dental Specialties, Tulsa, OK), ProTaper Gold (PTG; Dentsply Tulsa Dental Specialties), Self-Adjusting File (SAF; ReDent Nova, Ra'anana, Israel), and XP-endo Shaper (XP; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments using micro-computed tomographic (CT) analysis. Forty extracted human mandibular premolars having single-canal and straight root were randomly assigned to 4 experimental groups (n = 10) according to the different nickel-titanium systems used for root canal preparation: PTU, PTG, SAF, and XP. In the SAF and XP groups, the canals were first prepared with a K-file until #25 at the working length, and then the SAF or XP files were used. The specimens were scanned using high-resolution micro-computed tomographic imaging before and after root canal preparation. Afterward, preoperative and postoperative cross-sectional images of the teeth were screened to identify the presence of dentinal defects. For each group, the number of microcracks was determined as a percentage rate. The McNemar test was used to determine significant differences before and after instrumentation. The level of significance was set at P ≤ .05. The PTU system significantly increased the percentage rate of microcracks compared with preoperative specimens (P < .05). No new dentinal microcracks were observed in the PTG, SAF, or XP groups. Root canal preparations with the PTG, SAF, and XP systems did not induce the formation of new dentinal microcracks on straight root canals of mandibular premolars. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. A novel Xp22.13 microdeletion in Nance-Horan syndrome.

    PubMed

    Accogli, Andrea; Traverso, Monica; Madia, Francesca; Bellini, Tommaso; Vari, Maria Stella; Pinto, Francesca; Capra, Valeria

    2017-07-03

    Nance-Horan syndrome (NHS) is a rare X-linked developmental disorder characterized by congenital cataract, dental anomalies and facial dysmorphisms. Notably, up to 30% of NHS patients have intellectual disability and a few patients have been reported to have congenital cardiac defects. Nance-Horan syndrome is caused by mutations in the NHS gene that is highly expressed in the midbrain, retina, lens, tooth, and is conserved across vertebrate species. Although most pathogenic mutations are nonsense mutations, a few genomic rearrangements involving NHS locus have been reported, suggesting a possible pathogenic role of the flanking genes. Here, we report a microdeletion of 170,6 Kb at Xp22.13 (17.733.948-17.904.576) (GRCh37/hg19), detected by array-based comparative genomic hybridization in an Italian boy with NHS syndrome. The microdeletion harbors the NHS, SCLML1, and RAI2 genes and results in a phenotype consistent with NSH syndrome and developmental delay. We compare our case with the previous Xp22.13 microdeletions and discuss the possible pathogenetic role of the flanking genes. Birth Defects Research 109:866-868, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. Generating high-power short terahertz electromagnetic pulses with a multifoil radiator.

    PubMed

    Vinokurov, Nikolay A; Jeong, Young Uk

    2013-02-08

    We describe a multifoil cone radiator capable of generating high-field short terahertz pulses using short electron bunches. Round flat conducting foil plates with successively decreasing radii are stacked, forming a truncated cone with the z axis. The gaps between the foil plates are equal and filled with some dielectric (or vacuum). A short relativistic electron bunch propagates along the z axis. At sufficiently high particle energy, the energy losses and multiple scattering do not change the bunch shape significantly. When passing by each gap between the foil plates, the electron bunch emits some energy into the gap. Then, the radiation pulses propagate radially outward. For transverse electromagnetic waves with a longitudinal (along the z axis) electric field and an azimuthal magnetic field, there is no dispersion in these radial lines; therefore, the radiation pulses conserve their shapes (time dependence). At the outer surface of the cone, we have synchronous circular radiators. Their radiation field forms a conical wave. Ultrashort terahertz pulses with gigawatt-level peak power can be generated with this device.

  15. Usefulness of a break-apart FISH assay in the diagnosis of Xp11.2 translocation renal cell carcinoma.

    PubMed

    Kim, Soo Hee; Choi, Yoomi; Jeong, Hae Yeon; Lee, Kyoungbun; Chae, Ji Youn; Moon, Kyung Chul

    2011-09-01

    Xp11.2 translocation renal cell carcinoma (RCC) is a rare subtype of RCC predominantly reported in young patients. It results from gene fusions between the transcription factor E3 (TFE3) gene, which is located on chromosome Xp11.2, and various fusion partners. Recently, a dual color, break-apart fluorescence in situ hybridization (FISH) assay to detect Xp11.2 translocation was reported. We performed this study to evaluate the usefulness of the FISH assay in the diagnosis of Xp11.2 translocation RCC using a commercially available TFE3 break-apart probe. We immunohistochemically analyzed TFE3 nuclear expression in 809 cases of RCCs using 14 tissue microarray blocks and selected nine cases those showed moderate to strong positive nuclear immunoreactivity for TFE3. The extent of TFE3 nuclear expression was variable. The TFE3 FISH assay was performed in these 9 selected cases and 44 negative control cases. Only four out of nine selected cases showed the TFE3 break-apart signal. TFE3 FISH-positive cases mainly showed diffuse and strong TFE3 immunopositivity, but one case revealed focal and moderate TFE3 staining. On the contrary, TFE3 FISH-negative cases mainly revealed focal and moderate TFE3 immunoreactivity, however, one FISH-negative case revealed diffuse and strong TFE3 nuclear immunopositivity. All negative control cases revealed normal TFE3 FISH results. Our results reveal that TFE3 immunohistochemistry can show false-positive results, and that the TFE3 break-apart FISH assay is a useful complementary method for confirming the diagnosis of Xp11.2 translocation RCC.

  16. [The electroporation effects of high power pulse microwave and electromagnetic pulse irradiation on the membranes of cardiomyocyte cells and the mechanism therein involved].

    PubMed

    Deng, Hua; Wang, Dewen; Peng, Ruiyun; Wang, Shuiming; Chen, Jiankui; Zhang, Sa; Dong, Bo; Wang, Xiaomin

    2005-08-01

    Though there is ongoing public concern on potential hazards and risk of electromagnetic radiation, the bioeffects mechanism of electromagnetic fields remains obscure. Heart is one of the organs susceptive to electromagnetic fields (EMF). This study was designed to assess the influence of high power pulse microwave and electromagnetic pulse irradiation on cardiomyocytes, to explore the critical mechanism of electromagnetic fields, and to explain the regular course of injury caused by exposure to pulse EMF. Cultured cardiomyocytes were irradiated by high power pulse microwave and electromagnetic pulse first, then a series of apparatus including atom force microscope, laser scanning confocal microscope and flow cytometer were used to examine the changes of cell membrane conformation, structure and function. After irradiation, the cardiomyocytes pulsated slower or stop, the cells conformation was abnormal, the cells viability declined, and the percentage of apoptosis and necrosis increased significantly (P< 0.01). The cell membrane had pores unequal in size, and lost its penetration character. The concentration of Na+, K+, Ca2+, Cl-, Mg2+, Ca2+ and P3+ in cell culture medium increased significantly (P< 0.01). and the concentration of Ca2+ in cells ([Ca2+]i) decreased significantly (P<0.01). The results indicated that cardiomyocytes are susceptible to non-ionizing radiation. Pulse electromagnetic field can induce cardiomyocytes electroporation, and can do great damage to cells conformation, structure and function. Electroporation is one of the most critical mechanisms to explain the athermal effects of electromagnetic radiation.

  17. A case of metastatic Xp11.2 translocation renal cell carcinoma successfully managed by cytoreductive nephrectomy followed by axitinib therapy.

    PubMed

    Nishimura, Koichi; Takagi, Toshio; Toda, Naohiro; Yamamoto, Tomoko; Kondo, Tsunenori; Ishida, Hideki; Nagashima, Yoji; Tanabe, Kazunari

    2017-03-01

    Targeted medications for metastatic adult Xp11.2 translocation renal cell carcinoma (RCC) remain to be identified. We herein report a case of metastatic Xp11.2 translocation RCC controlled with cytoreductive nephrectomy (CN) and axitinib therapy. A 57-year-old woman complained of fatigue and low back pain. Imaging studies revealed a right renal tumor, with multiple lung and mediastinal lymph node metastases. Although the patient received 10 mg axitinib therapy for 5 months at the hospital she was initially admitted to, the size of the primary and metastatic lesions was not reduced. Thus, she was referred to the Tokyo Women's Medical University Hospital (Tokyo, Japan) for further treatment, where she underwent CN. On macroscopic examination, almost the entire kidney was replaced by a yellowish brown tumor >80 mm in diameter. Immunohistochemical examination confirmed the diagnosis of Xp11.2 translocation RCC. One month after surgery, axitinib therapy was resumed and the size of the metastatic lesions gradually decreased. These findings suggest that axitinib therapy is effective for adult Xp11.2 translocation RCC.

  18. A case of metastatic Xp11.2 translocation renal cell carcinoma successfully managed by cytoreductive nephrectomy followed by axitinib therapy

    PubMed Central

    Nishimura, Koichi; Takagi, Toshio; Toda, Naohiro; Yamamoto, Tomoko; Kondo, Tsunenori; Ishida, Hideki; Nagashima, Yoji; Tanabe, Kazunari

    2017-01-01

    Targeted medications for metastatic adult Xp11.2 translocation renal cell carcinoma (RCC) remain to be identified. We herein report a case of metastatic Xp11.2 translocation RCC controlled with cytoreductive nephrectomy (CN) and axitinib therapy. A 57-year-old woman complained of fatigue and low back pain. Imaging studies revealed a right renal tumor, with multiple lung and mediastinal lymph node metastases. Although the patient received 10 mg axitinib therapy for 5 months at the hospital she was initially admitted to, the size of the primary and metastatic lesions was not reduced. Thus, she was referred to the Tokyo Women's Medical University Hospital (Tokyo, Japan) for further treatment, where she underwent CN. On macroscopic examination, almost the entire kidney was replaced by a yellowish brown tumor >80 mm in diameter. Immunohistochemical examination confirmed the diagnosis of Xp11.2 translocation RCC. One month after surgery, axitinib therapy was resumed and the size of the metastatic lesions gradually decreased. These findings suggest that axitinib therapy is effective for adult Xp11.2 translocation RCC. PMID:28451413

  19. Towards Integrated Pulse Detonation Propulsion and MHD Power

    NASA Technical Reports Server (NTRS)

    Litchford, Ron J.; Thompson, Bryan R.; Lineberry, John T.

    1999-01-01

    The interest in pulse detonation engines (PDE) arises primarily from the advantages that accrue from the significant combustion pressure rise that is developed in the detonation process. Conventional rocket engines, for example, must obtain all of their compression from the turbopumps, while the PDE provides additional compression in the combustor. Thus PDE's are expected to achieve higher I(sub sp) than conventional rocket engines and to require smaller turbopumps. The increase in I(sub sp) and the decrease in turbopump capacity must be traded off against each other. Additional advantages include the ability to vary thrust level by adjusting the firing rate rather than throttling the flow through injector elements. The common conclusion derived from these aggregated performance attributes is that PDEs should result in engines which are smaller, lower in cost, and lighter in weight than conventional engines. Unfortunately, the analysis of PDEs is highly complex due to their unsteady operation and non-ideal processes. Although the feasibility of the basic PDE concept has been proven in several experimental and theoretical efforts, the implied performance improvements have yet to be convincingly demonstrated. Also, there are certain developmental issues affecting the practical application of pulse detonation propulsion systems which are yet to be fully resolved. Practical detonation combustion engines, for example, require a repetitive cycle of charge induction, mixing, initiation/propagation of the detonation wave, and expulsion/scavenging of the combustion product gases. Clearly, the performance and power density of such a device depends upon the maximum rate at which this cycle can be successfully implemented. In addition, the electrical energy required for direct detonation initiation can be significant, and a means for direct electrical power production is needed to achieve self-sustained engine operation. This work addresses the technological issues associated

  20. A 16 MJ compact pulsed power system for electromagnetic launch

    NASA Astrophysics Data System (ADS)

    Dai, Ling; Zhang, Qin; Zhong, Heqing; Lin, Fuchang; Li, Hua; Wang, Yan; Su, Cheng; Huang, Qinghua; Chen, Xu

    2015-07-01

    This paper has established a compact pulsed power system (PPS) of 16 MJ for electromagnetic rail gun. The PPS consists of pulsed forming network (PFN), chargers, monitoring system, and current junction. The PFN is composed of 156 pulse forming units (PFUs). Every PFU can be triggered simultaneously or sequentially in order to obtain different total current waveforms. The whole device except general control table is divided into two frameworks with size of 7.5 m × 2.2 m × 2.3 m. It is important to estimate the discharge current of PFU accurately for the design of the whole electromagnetic launch system. In this paper, the on-state characteristics of pulse thyristor have been researched to improve the estimation accuracy. The on-state characteristics of pulse thyristor are expressed as a logarithmic function based on experimental data. The circuit current waveform of the single PFU agrees with the simulating one. On the other hand, the coaxial discharge cable is a quick wear part in PFU because the discharge current will be up to dozens of kA even hundreds of kA. In this article, the electromagnetic field existing in the coaxial cable is calculated by finite element method. On basis of the calculation results, the structure of cable is optimized in order to improve the limit current value of the cable. At the end of the paper, the experiment current wave of the PPS with the load of rail gun is provided.

  1. A 16 MJ compact pulsed power system for electromagnetic launch.

    PubMed

    Dai, Ling; Zhang, Qin; Zhong, Heqing; Lin, Fuchang; Li, Hua; Wang, Yan; Su, Cheng; Huang, Qinghua; Chen, Xu

    2015-07-01

    This paper has established a compact pulsed power system (PPS) of 16 MJ for electromagnetic rail gun. The PPS consists of pulsed forming network (PFN), chargers, monitoring system, and current junction. The PFN is composed of 156 pulse forming units (PFUs). Every PFU can be triggered simultaneously or sequentially in order to obtain different total current waveforms. The whole device except general control table is divided into two frameworks with size of 7.5 m × 2.2 m × 2.3 m. It is important to estimate the discharge current of PFU accurately for the design of the whole electromagnetic launch system. In this paper, the on-state characteristics of pulse thyristor have been researched to improve the estimation accuracy. The on-state characteristics of pulse thyristor are expressed as a logarithmic function based on experimental data. The circuit current waveform of the single PFU agrees with the simulating one. On the other hand, the coaxial discharge cable is a quick wear part in PFU because the discharge current will be up to dozens of kA even hundreds of kA. In this article, the electromagnetic field existing in the coaxial cable is calculated by finite element method. On basis of the calculation results, the structure of cable is optimized in order to improve the limit current value of the cable. At the end of the paper, the experiment current wave of the PPS with the load of rail gun is provided.

  2. Single-cycle powerful megawatt to gigawatt terahertz pulse radiated from a wavelength-scale plasma oscillator

    NASA Astrophysics Data System (ADS)

    Wu, Hui-Chun; Sheng, Zheng-Ming; Zhang, Jie

    2008-04-01

    We propose a scheme to generate single-cycle powerful terahertz (THz) pulses by ultrashort intense laser pulses obliquely incident on an underdense plasma slab of a few THz wavelengths in thickness. THz waves are radiated from a transient net current driven by the laser ponderomotive force in the plasma slab. Analysis and particle-in-cell simulations show that such a THz source is capable of providing power of megawatts to gigawatts, field strength of MV/cm-GV/cm, and broad tunability range, which is potentially useful for nonlinear and high-field THz science and applications.

  3. Spin and Recovery Characteristics of the Curtiss-Wright XP-87 Airplane

    NASA Technical Reports Server (NTRS)

    Berman, Theodore

    1947-01-01

    The spin and recovery characteristics of the Curtiss-Wright XP-87 airplane, as well as the spin-recovery parachute requirements, the control forces that would be encountered in the spin, and the best method for the crew to attempt an emergency escape, are presented in this report. The characteristics were estimated rather than determined by model tests because the XP-87 dimensional and mass characteristics were considered to be noncritical and because data were available from model tests of several similar airplanes. The study indicated that the recovery characteristics of the airplane will be satisfactory for all loadings if the controls are reversed fully and rapidly. The control forces, however, will probably be beyond the capabilities of the pilot unless some additional balance or a booster is used. A 6-foot tail parachute or a 3.5-foot wing-tip parachute with a drag coefficient of 0.7 will be a satisfactory, emergency spin-recovery device for spin demonstrations. If it is necessary for the crew to abandon the spinning airplane, they should leave from the outboard side of the cockpit.

  4. Compact high-power optical source for resonant infrared pulsed laser ablation and deposition of polymer materials

    NASA Astrophysics Data System (ADS)

    Kolev, V. Z.; Duering, M. W.; Luther-Davies, B.; Rode, A. V.

    2006-12-01

    We propose a novel tuneable table-top optical source as an alternative to the free electron laser currently used for resonant infrared pulsed laser deposition of polymers. It is based on two-stage pulsed optical parametric amplification using MgO doped periodically poled lithium niobate crystals. Gain in excess of 106 in the first stage and pump depletion of 58% in the second stage were achieved when the system was pumped by a high-power Nd:YVO4 picosecond laser source at 1064 nm and seeded by a CW tuneable diode laser at 1530 nm. An average power of 2 W was generated at 3.5 µm corresponding to 1.3 µJ pulse energy.

  5. Pulsed Power Science and Technology: A Strategic Outlook for the National Nuclear Security Administration (Summary)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinars, Daniel; Scott, Kimberly Carole; Edwards, M. John

    Major advances in pulsed power technology and applications over the last twenty years have expanded the mission areas for pulsed power and created compelling new opportunities for the Stockpile Stewardship Program (SSP). This summary document is a forward look at the development of pulsed power science and technology (PPS&T) capabilities in support of the next 20 years of the SSP. This outlook was developed during a three-month-long tri-lab study on the future of PPS&T research and capabilities in support of applications to: (1) Dynamic Materials, (2) Thermonuclear Burn Physics and Inertial Confinement Fusion (ICF), and (3) Radiation Effects and Nuclearmore » Survivability. It also considers necessary associated developments in next-generation codes and pulsed power technology as well as opportunities for academic, industry, and international engagement. The document identifies both imperatives and opportunities to address future SSP mission needs. This study was commissioned by the National Nuclear Security Administration (NNSA). A copy of the memo request is contained in the Appendix. NNSA guidance received during this study explicitly directed that it not be constrained by resource limitations and not attempt to prioritize its findings against plans and priorities in other areas of the national weapons program. That prioritization, including the relative balance amongst the three focus areas themselves, must of course occur before any action is taken on the observations presented herein. This unclassified summary document presents the principal imperatives and opportunities identified in each mission and supporting area during this study. Preceding this area-specific outlook, we discuss a cross-cutting opportunity to increase the shot capacity on the Z pulsed power facility as a near-term, cost-effective way to broadly impact PPS&T for SSP as well as advancing the science and technology to inform future SSMP milestones over the next 5-10 years. The final page

  6. Rust and paint stripping from power transmission towers with a pulsed Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Ashidate, Shu-ichi; Obara, Minoru

    1997-04-01

    The possibility of the rust and paint removal from the power transmission towers was investigated with the pulsed Nd:YAG laser for the first time. The red rust and paint were successfully removed without damaging underlying Zn(zinc) galvanized steel substrates. The optimum irradiated laser fluence for the red rust was found from 0.3 J/cm2 to 0.4 J/cm2 for 9 ns short pulses, from 1.0 J/cm2 to 4.4 J/cm2 for 200 ns long pulses, respectively. For the paint stripping the optimum ranged from 3.3 J/cm2 to 4.4 J/cm2 with the pulse width of 200 ns.

  7. Electro-optically cavity dumped 2 μm semiconductor disk laser emitting 3 ns pulses of 30 W peak power

    NASA Astrophysics Data System (ADS)

    Kaspar, Sebastian; Rattunde, Marcel; Töpper, Tino; Schwarz, Ulrich T.; Manz, Christian; Köhler, Klaus; Wagner, Joachim

    2012-10-01

    A 2 μm electro-optically cavity-dumped semiconductor disk laser (SDL) with a pulse full width at half maximum of 3 ns, a pulse peak power of 30 W, and repetition rates adjustable between 87 kHz and 1 MHz is reported. For ns-pulse cavity dumping the SDL was set up with a 35-cm long cavity into which an intra-cavity Brewster-angled polarizer prism and a Pockels cell for rotation of the linear polarization were inserted. By means of internal total reflection in the birefringent polarizer, pulses are coupled out of the cavity sideways. This variant of ns-pulse 2-μm SDL is well suited for applications such as high-precision light detection and ranging or ns-pulse laser materials processing after further power amplification.

  8. Xp11.2 translocation tumor: a rare cause of gross hematuria.

    PubMed

    Asaki, Howard E; Moshero, Gianni; Stanton, Melissa L; Humphreys, Mitchell R

    2014-02-01

    Xp11.2 translocation tumor is a rare but aggressive form of renal cell carcinoma that predominantly occurs in children but also may be found in young adults. Because this type of cancer is diagnosed via histologic and chromosomal analysis, clinicians should consider translocation tumor in the differential diagnosis of patients with renal lesions and gross hematuria.

  9. Novel high-frequency, high-power, pulsed oscillator based on a transmission line transformer.

    PubMed

    Burdt, R; Curry, R D

    2007-07-01

    Recent analysis and experiments have demonstrated the potential for transmission line transformers to be employed as compact, high-frequency, high-power, pulsed oscillators with variable rise time, high output impedance, and high operating efficiency. A prototype system was fabricated and tested that generates a damped sinusoidal wave form at a center frequency of 4 MHz into a 200 Omega load, with operating efficiency above 90% and peak power on the order of 10 MW. The initial rise time of the pulse is variable and two experiments were conducted to demonstrate initial rise times of 12 and 3 ns, corresponding to a spectral content from 4-30 and from 4-100 MHz, respectively. A SPICE model has been developed to accurately predict the circuit behavior and scaling laws have been identified to allow for circuit design at higher frequencies and higher peak power. The applications, circuit analysis, test stand, experimental results, circuit modeling, and design of future systems are all discussed.

  10. A Q-band low noise GaAs pHEMT MMIC power amplifier for pulse electron spin resonance spectrometer

    NASA Astrophysics Data System (ADS)

    Sitnikov, A.; Kalabukhova, E.; Oliynyk, V.; Kolisnichenko, M.

    2017-05-01

    We present the design and development of a single stage pulse power amplifier working in the frequency range 32-38 GHz based on a monolithic microwave integrated circuit (MMIC). We have designed the MMIC power amplifier by using the commercially available packaged GaAs pseudomorphic high electron mobility transistor. The circuit fabrication and assembly process includes the elaboration of the matching networks for the MMIC power amplifier and their assembling as well as the topology outline and fabrication of the printed circuit board of the waveguide-microstrip line transitions. At room ambient temperature, the measured peak output power from the prototype amplifier is 35.5 dBm for 16.6 dBm input driving power, corresponding to 19 dB gain. The measured rise/fall time of the output microwave signal modulated by a high-speed PIN diode was obtained as 5-6 ns at 20-250 ns pulse width with 100 kHz pulse repetition rate frequency.

  11. A Q-band low noise GaAs pHEMT MMIC power amplifier for pulse electron spin resonance spectrometer.

    PubMed

    Sitnikov, A; Kalabukhova, E; Oliynyk, V; Kolisnichenko, M

    2017-05-01

    We present the design and development of a single stage pulse power amplifier working in the frequency range 32-38 GHz based on a monolithic microwave integrated circuit (MMIC). We have designed the MMIC power amplifier by using the commercially available packaged GaAs pseudomorphic high electron mobility transistor. The circuit fabrication and assembly process includes the elaboration of the matching networks for the MMIC power amplifier and their assembling as well as the topology outline and fabrication of the printed circuit board of the waveguide-microstrip line transitions. At room ambient temperature, the measured peak output power from the prototype amplifier is 35.5 dBm for 16.6 dBm input driving power, corresponding to 19 dB gain. The measured rise/fall time of the output microwave signal modulated by a high-speed PIN diode was obtained as 5-6 ns at 20-250 ns pulse width with 100 kHz pulse repetition rate frequency.

  12. Effect of Pressure on Some Optical Properties of GaxIn1-xP Semiconductors

    NASA Astrophysics Data System (ADS)

    Vyas, P.; Gajjar, P.; Jani, A.

    2013-06-01

    A theoretical procedure is presented for the study of optical properties of ternary alloy GaxIn1-xP. The calculations are based on the pseudopotential formalism in which local potential coupled with the virtual crystal approximation (VCA) is applied to evaluate the effect of pressure on the optical properties like refractive index, electronic polarizability, plasmon energy, dielectric constant and equation of state for gallium concentration x = 0, 0.25, 0.50, 0.75 and 1 of the ternary alloy GaxIn1-xP. To incorporate the screening effect, local field correction functions due to Hartree, Taylor, Ichimaru et al. and Nagy are employed. The refractive index, electronic polarizability and dielectric constant computed for the parent binary compounds GaP and InP are found to be satisfactorily agreeing with the experimental report. It is seen that the refractive index of GaxIn1-xP decreases nonlinearly with the increase in pressure. The results obtained using Hartree's screening functions are not very close to the experimental data as it does not include any exchange and correlation effects. Overall good agreement with the experimental and other theoretical findings confirms the application. The author P. S. Vyas is thankful to UGC, New Delhi, India for providing financial support under minor research project No. F.: 47-651/08(WRO).

  13. Study and development of 22 kW peak power fiber coupled short pulse Nd:YAG laser for cleaning applications

    NASA Astrophysics Data System (ADS)

    Choubey, Ambar; Vishwakarma, S. C.; Vachhani, D. M.; Singh, Ravindra; Misra, Pushkar; Jain, R. K.; Arya, R.; Upadhyaya, B. N.; Oak, S. M.

    2014-11-01

    Free running short pulse Nd:YAG laser of microsecond pulse duration and high peak power has a unique capability to ablate material from the surface without heat propagation into the bulk. Applications of short pulse Nd:YAG lasers include cleaning and restoration of marble, stones, and a variety of metals for conservation. A study on the development of high peak power short pulses from Nd:YAG laser along with its cleaning and conservation applications has been performed. A pulse energy of 1.25 J with 55 μs pulse duration and a maximum peak power of 22 kW has been achieved. Laser beam has an M2 value of ~28 and a pulse-to-pulse stability of ±2.5%. A lower value of M2 means a better beam quality of the laser in multimode operation. A top hat spatial profile of the laser beam was achieved at the exit end of 200 μm core diameter optical fiber, which is desirable for uniform cleaning. This laser system has been evaluated for efficient cleaning of surface contaminations on marble, zircaloy, and inconel materials for conservation with cleaning efficiency as high as 98%. Laser's cleaning quality and efficiency have been analysed by using a microscope, a scanning electron microscope (SEM), and X-ray photon spectroscopy (XPS) measurements.

  14. The characterization of secondary lithium-ion battery degradation when operating complex, ultra-high power pulsed loads

    NASA Astrophysics Data System (ADS)

    Wong, Derek N.

    The US Navy is actively developing all electric fleets, raising serious questions about what is required of onboard power supplies in order to properly power the ship's electrical systems. This is especially relevant when choosing a viable power source to drive high power propulsion and electric weapon systems in addition to the conventional loads deployed aboard these types of vessels. Especially when high pulsed power loads are supplied, the issue of maintaining power quality becomes important and increasingly complex. Conventionally, a vessel's electrical power is generated using gas turbine or diesel driven motor-generator sets that are very inefficient when they are used outside of their most efficient load condition. What this means is that if the generator is not being utilized continuously at its most efficient load capacity, the quality of the output power may also be effected and fall outside of the acceptable power quality limits imposed through military standards. As a solution to this potential problem, the Navy has proposed using electrochemical storage devices since they are able to buffer conventional generators when the load is operating below the generator's most efficient power level or able to efficiently augment a generator when the load is operating in excess of the generator's most efficient power rating. Specifically, the US Navy is interested in using commercial off-the-shelf (COTS) lithium-ion batteries within an intelligently controlled energy storage module that could act as either a prime power supply for on-board pulsed power systems or as a backup generator to other shipboard power systems. Due to the unique load profile of high-rate pulsed power systems, the implementation of lithium-ion batteries within these complex systems requires them to be operated at very high rates and the effects these things have on cell degradation has been an area of focus. There is very little published research into the effects that high power transient

  15. [Differential diagnosis between renal cell carcinoma associated with XP11.2 translocation/TFE gene fusion and papillary renal cell carcinoma based on CT and MRI findings].

    PubMed

    Zhu, Qingqiang; Zhu, Wenrong; Wu, Jingtao; Fu, Jianxiong; Chen, Wenxin; Wang, Zhongqiu

    2014-05-20

    To comparative study of CT and MRI appearances in renal cell carcinoma associated with XP11.2 translocation/TFE gene fusion (XP11.2 RCC) and papillary renal cell carcinoma (PRCC). 12 patients with XP11.2 RCC and 18 patients with PRCC were retrospectively studied, and the data was analyzed by AVONA and chi-square text. 12 patients with XP11.2 RCC and 18 patients with PRCC, cystic components (2 vs 11, P < 0.05), calcification (0 vs 6, P < 0.05), hemorrhage (9 vs 5, P < 0.05), homogeneous enhancement (10 vs 7, P < 0.05) and had lymph node (3 vs 0) or hepatic metastasis (1vs 0) (P < 0.05). On unenhanced CT, the density of XP11.2 RCC was greater than PRCC, normal renal cortex or medulla (P < 0.05). Their degree of enhancement were less than normal renal cortex on all enhanced phases (P < 0.05). The enhancement degree of XP11.2 RCC was higher than PRCC (on all phases) and renal medulla (on cortical and medullary phase) (P < 0.05), but less than normal renal medulla on the delayed phase (P < 0.05). The enhancement degree of PRCC was lower than renal medulla on all phases (P < 0.05). The XP11.2 RCC was isointense on T1-weighted imaging, hypointense on T2-weighted imaging. The PRCC was isointense or hypointense on T1-weighted imaging, isointense on T2-weighted imaging. The CT and MRI could show imagings features of XP11.2 RCC and PRCC, and these features were helpful in predicting a specific subtype of renal cell carcinoma.

  16. Power scaling of supercontinuum seeded megahertz-repetition rate optical parametric chirped pulse amplifiers.

    PubMed

    Riedel, R; Stephanides, A; Prandolini, M J; Gronloh, B; Jungbluth, B; Mans, T; Tavella, F

    2014-03-15

    Optical parametric chirped-pulse amplifiers with high average power are possible with novel high-power Yb:YAG amplifiers with kW-level output powers. We demonstrate a compact wavelength-tunable sub-30-fs amplifier with 11.4 W average power with 20.7% pump-to-signal conversion efficiency. For parametric amplification, a beta-barium borate crystal is pumped by a 140 W, 1 ps Yb:YAG InnoSlab amplifier at 3.25 MHz repetition rate. The broadband seed is generated via supercontinuum generation in a YAG crystal.

  17. Multi-pulse power injection and spheromak sustainment in SSPX

    NASA Astrophysics Data System (ADS)

    Stallard, B. W.; Hill, D. N.; Hooper, E. B.; Bulmer, R. H.; McLean, H. S.; Wood, R. D.; Woodruff, S.; Sspx Team

    2000-10-01

    Lawrence Livermore National Laboratory, Livermore, CA 94550, USA. Spheromak formation (gun injection phase) and sustainment experiments are now routine in SSPX using a multi-bank power system. Gun voltage, impedance, and power coupling show a clear current threshold dependence on gun flux (I_th~=λ_0φ_gun/μ_0), increasing with current above the threshold, and are compared with CTX results. The characteristic gun inductance, L_gun~=0.6 μH, derived from the gun voltage dependence on di/dt, is larger than expected from Corsica modeling of the spheromak equilibrium. It’s value is consistent with the n=1 ‘doughook’ mode structure reported in SPHEX and believed important for helicity injection and toroidal current drive. Results of helicity and power balance calculations of spheromak poloidal field buildup are compared with experiment and used to project sustainment with a future longer pulse power supply. This work was performed under the auspices of US DOE by the University of California Lawrence Livermore National Laboratory under Contract No. W-7405-ENG-48.

  18. XP11.2 translocation renal cell carcinoma: clinical experience of Taipei Veterans General Hospital.

    PubMed

    Hung, Chia-Chen; Pan, Chin-Chen; Lin, Chih-Chieh; Lin, Alex T L; Chen, Kuang-Kuo; Chang, Yen-Hwa

    2011-11-01

    Xp11.2 translocation renal cell carcinoma (RCC), a recently recognized distinct subtype of RCC, is characterized by various translocations, all involving the TFE3 transcription factor gene. These rare cancers occur predominantly in children and young adults and comprise about one-third of pediatric RCCs. In the present study, we review the clinical course of Xp11.2 translocation renal cell carcinoma in our institution. We identified eight cases with Xp11.2 translocation RCC between 2007 and 2010 from the pathological archives of the Taipei Veterans General Hospital. We retrospectively analyzed the patients' characteristics, clinical manifestations, and specific pathological features for definitive diagnosis, surgical and systemic treatment and clinical outcome of these rare cancers. Patients were aged 20 years to 49 years (mean age 28 years) with female predominance (6 females, 2 males). One patient presented with asymptomatic renal mass detected incidentally during abdominal sonography. Four patients complained of flank or abdominal pain, and the other three complained of gross hematuria at initial presentation. The mean tumor size was 9.2 cm (range, 4 cm-17 cm). Seven patients underwent radical nephrectomy for the primary tumor, while one presented with multiple metastases. All cases were confirmed by TFE3 immunohistochemistry, a sensitive and specific marker of tumors with TFE3 gene fusion, which showed positive nuclear staining. Three patients presented initially with metastatic diseases, and another three patients progressed to lung, liver and bone metastases at eight, seven and nine months postoperatively. Although RT-PCR and DNA sequencing are the final diagnoses of the molecular identity of Xp11.2 translocation RCC, experienced pathologists could confirm the histologic diagnosis based on the distinctive morphologic features with positive TFE3 immunochemical nuclear stain. Surgical resection is the only treatment. The role of systemic therapy for local

  19. Pulse power switch development

    NASA Astrophysics Data System (ADS)

    Harvey, R.; Gallagher, H.; Hansen, S.

    1980-01-01

    The objective of this study program has been to define an optimum technical approach to the longer range goal of achieving practical high repetition rate high power spark gap switches. Requirements and possible means of extending the state of the art of crossed field closing switches, vacuum spark gaps, and pressurized spark gaps are presented with emphasis on reliable, efficient and compact devices operable in burst mode at 250-300 kV, 40-60 kA, =1 kHz with approximately 50 nsec pulses rising in approximately 3 ns. Models of these devices are discussed which are based upon published and generated design data and on underlying physical principles. Based upon its relative advantages, limitations and tradeoffs we conclude that the Hughes Crossatron switch is the nearest term approach to reach the switch goal levels. Theoretical, experimental, and computer simulation models of the plasma show a collective ion acceleration mechanism to be active which is predicted to result in current rise times approaching 10 nsec. A preliminary design concept is presented. For faster rise times we have shown a vacuum surface flashover switch to be an interesting candidate. This device is limited by trigger instabilities and will require further basic development. The problem areas relevant to high pressure spark gaps are reviewed.

  20. New X-linked mental retardation syndrome with the gene mapped tentatively in Xp22.3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wittwer, B.; Kircheisen, R.; Leutelt, J.

    1996-07-12

    X-linked mental retardation (XLMR) is genetically heterogeneous and clinically variable. We describe a new XLMR syndrome of severe mental retardation and multiple congenital anomalies. Two sisters have (with 3 different partners) 3 severely handicapped sons. In 2 cases, oligohydramnios and intrauterine growth retardation were noted. Common anomalies included a square-shaped face, high and broad forehead, frontal bossing, downward slant of palpebral fissures, hypertelorism, epicanthic folds, long philtrum, thin upper lip, and apparently low-set ears. One boy has bilateral microphthalmos and sclerocornea, and his cousin has atrophy of the optic nerve. All 3 patients are blind and have profound statomotor andmore » mental retardation, seizures, and a grossly abnormal electroencephalographic pattern. Additional findings are short stature, delayed bone matuation, hydronephrosis, vesicorenal reflux, cryptorchidism, clinodactyly of the 5th fingers, and transverse palmar creases. The karyotype is normal (46,XY). Segregation analysis showed perfect coinheritance between the clinical phenotype and alleles at several loci in Xp22.3, whereas recombinants were identified with marker loci from Xp22.2-qter. Analysis of multiple informative meioses suggests that the disease locus maps in Xp22.3 distal to DXS16. 9 refs., 5 figs., 2 tabs.« less

  1. A vacuum-sealed, gigawatt-class, repetitively pulsed high-power microwave source

    NASA Astrophysics Data System (ADS)

    Xun, Tao; Fan, Yu-wei; Yang, Han-wu; Zhang, Zi-cheng; Chen, Dong-qun; Zhang, Jian-de

    2017-06-01

    A compact L-band sealed-tube magnetically insulated transmission line oscillator (MILO) has been developed that does not require bulky external vacuum pump for repetitive operations. This device with a ceramic insulated vacuum interface, a carbon fiber array cathode, and non-evaporable getters has a base vacuum pressure in the low 10-6 Pa range. A dynamic 3-D Monte-Carlo model for the molecular flow movement and collision was setup for the MILO chamber. The pulse desorption, gas evolution, and pressure distribution were exactly simulated. In the 5 Hz repetition rate experiments, using a 600 kV diode voltage and 48 kA beam current, the average radiated microwave power for 25 shots is about 3.4 GW in 45 ns pulse duration. The maximum equilibrium pressure is below 4.0 × 10-2 Pa, and no pulse shortening limitations are observed during the repetitive test in the sealed-tube condition.

  2. Perivascular epithelioid cell tumor (PEComa) of the urinary bladder associated with Xp11 translocation.

    PubMed

    Russell, Christopher M; Buethe, David D; Dickinson, Shohreh; Sexton, Wade J

    2014-01-01

    Perivascular epithelioid cell-containing tumors (PEComas) represent a rare family of neoplasms. Their dichotomous phenotypic features, including both myogenic and mylanocytic features, can make a definitive diagnosis difficult. Such tumors have been associated with the overexpression of transcription factor E3 (TFE3). An Xp11 translocation could account for the aberrant activity of TFE3 but has never before been described in affiliation with a PEComa of the urinary bladder. While PEComas of the bladder have exhibited benign clinical courses to date, here we present an intravesical PEComa shown to have an Xp11 translocation and resultant overexpression of TFE3, indicating an aggressive, metastatic nature. No consistent tumor characteristics have proven accurate at identifying aggressive tumors. However, mTOR inhibitors offer a mechanistic management strategy when systemic therapy is warranted.

  3. Experimental investigation of powerful pulse current generators based on capacitive storage and explosive magnetic generators

    NASA Astrophysics Data System (ADS)

    Shurupov, A. V.; Zavalova, V. E.; Kozlov, A. V.; Shurupov, M. A.; Povareshkin, M. N.; Kozlov, A. A.; Shurupova, N. P.

    2018-01-01

    Experimental models of microsecond duration powerful generators of current pulses on the basis of explosive magnetic generators and voltage impulse generator have been developed for the electromagnetic pulse effects on energy facilities to verify their stability. Exacerbation of voltage pulse carried out through the use of electro explosive current interrupter made of copper wires with diameters of 80 and 120 μm. Experimental results of these models investigation are represented. Voltage fronts about 100 ns and the electric field strength of 800 kV/m are registered.

  4. Preliminary Evaluation of the Low-Speed Stability and Control Characteristics of the McDonnell XP-85 Airplane from Tests of an Unballasted 1/5-Scale Model in the Langley Free-Flight Tunnel

    NASA Technical Reports Server (NTRS)

    Paulson, John W.; Johnson, Joseph L.

    1947-01-01

    At the request of the Air Material Command, Army Air Forces an investigation of the low-speed, power-off stability and control characteristics of the McDonnell XP-85 airplane is being conducted in the Langley free-flight tunnel. The XP-85 airplane is a jet propelled, parasite fighter with a 34 deg sweepback at the wing quarter chord. It was designed to be carried in a bomb bay of the B-36 air plane. The first portion of the investigation consists of a preliminary evaluation of the stability and control characteristics of the airplane from force and fight tests of an unballasted 1/5-scale model. The second portion of the investigation consists of test of a properly balasted 1/10-scale model which will include a study of the stability of the Xp-85 when attached to the trapeze for retraction into the B-36 bomb bay. The results of the preliminary test with the 1/5-scale model are presented herein. This portion fo the investigation included tests of the model with various center fin arrangements. Both the design nose flap and a stall control vane were investigated.

  5. Structural and magnetic phase transitions near optimal superconductivity in BaFe 2(As 1-xP x) 2

    DOE PAGES

    Hu, Ding; Lu, Xingye; Zhang, Wenliang; ...

    2015-04-17

    In this study, we use nuclear magnetic resonance (NMR), high-resolution x-ray and neutron scattering to study structural and magnetic phase transitions in phosphorus-doped BaFe 2(As 1-xP x) 2. Thus, previous transport, NMR, specific heat, and magnetic penetration depth measurements have provided compelling evidence for the presence of a quantum critical point (QCP) near optimal superconductivity at x = 0.3. However, we show that the tetragonal-to-orthorhombic structural (T s) and paramagnetic to antiferromagnetic (AF, T N) transitions in BaFe 2(As 1-xP x) 2 are always coupled and approach to T N ≈ T s ≥ T c (≈ 29 K) formore » x = 0.29 before vanishing abruptly for x ≥ 0.3. These results suggest that AF order in BaFe 2(As 1-xP x) 2 disappears in a weakly first order fashion near optimal superconductivity, much like the electron-doped iron pnictides with an avoided QCP.« less

  6. Long-term survival in a patient with node-positive adult-onset Xp11.2 translocation renal cell carcinoma.

    PubMed

    Aoyagi, Toshiki; Shinohara, Nobuo; Kubota-Chikai, Kanako; Kuroda, Naoto; Nonomura, Katsuya

    2011-01-01

    Adult-onset Xp11.2 translocation renal cell carcinoma is a rare malignancy that has an aggressive clinical course and poor prognosis. The reasons for this include the fact that most patients have an advanced clinical stage at diagnosis and also that there is a lack of effective systemic therapy. We herein present the case of a 32-year-old woman suffering from node-positive Xp11.2 translocation renal cell carcinoma who underwent radical nephrectomy with an extensive retroperitoneal lymph node dissection, followed by two times of surgical resection for recurrent nodal disease. The patient has experienced no recurrent disease 4.5 years after the last operation and remains free of disease. Surgical approach to recurrent disease, if the recurrent site can be judged to be limited, might be one of the feasible treatment options in patients with Xp11.2 translocation renal cell carcinoma. Copyright © 2011 S. Karger AG, Basel.

  7. Electron acceleration in pulsed-power driven magnetic-reconnection experiments

    NASA Astrophysics Data System (ADS)

    Halliday, Jonathan; Hare, Jack; Lebedev, Sergey; Suttle, Lee; Bland, Simon; Clayson, Thomas; Tubman, Eleanor; Pikuz, Sergei; Shelkovenko, Tanya

    2017-10-01

    We present recent results from pulsed-power driven magnetic reconnection experiments, fielded on the MAGPIE generator (1.2 MA, 250 ns). The setup used in these experiments produces plasma inflows which are intrinsically magnetised; persist for many hydrodynamic time-scales; and are supersonic. Previous work has focussed on characterising the dynamics of bulk plasma flows, using a suite of diagnostics including laser interferometry, (imaging) Faraday rotation, and Thompson scattering. Measurements show the formation of a well defined, long lasting reconnection layer and demonstrate a power balance between the power into and out of the reconnection region. The work presented here focuses on diagnosing non-thermal electron acceleration by the reconnecting electric field. To achieve this, metal foils were placed in the path of accelerated electrons. Atomic transitions in the foil were collisionally exited by the electron beam, producing a characteristic X-Ray spectrum. This X-Ray emission was diagnosed using spherically bent crystal X-Ray spectrometry, filtered X-Ray pinhole imaging, and X-Ray sensitive PIN diodes.

  8. An experimental platform for pulsed-power driven magnetic reconnection

    NASA Astrophysics Data System (ADS)

    Hare, J. D.; Suttle, L. G.; Lebedev, S. V.; Loureiro, N. F.; Ciardi, A.; Chittenden, J. P.; Clayson, T.; Eardley, S. J.; Garcia, C.; Halliday, J. W. D.; Robinson, T.; Smith, R. A.; Stuart, N.; Suzuki-Vidal, F.; Tubman, E. R.

    2018-05-01

    We describe a versatile pulsed-power driven platform for magnetic reconnection experiments, based on the exploding wire arrays driven in parallel [Suttle et al., Phys. Rev. Lett. 116, 225001 (2016)]. This platform produces inherently magnetised plasma flows for the duration of the generator current pulse (250 ns), resulting in a long-lasting reconnection layer. The layer exists for long enough to allow the evolution of complex processes such as plasmoid formation and movement to be diagnosed by a suite of high spatial and temporal resolution laser-based diagnostics. We can access a wide range of magnetic reconnection regimes by changing the wire material or moving the electrodes inside the wire arrays. We present results with aluminium and carbon wires, in which the parameters of the inflows and the layer that forms are significantly different. By moving the electrodes inside the wire arrays, we change how strongly the inflows are driven. This enables us to study both symmetric reconnection in a range of different regimes and asymmetric reconnection.

  9. Doping management for high-power fiber lasers: 100 W, few-picosecond pulse generation from an all-fiber-integrated amplifier.

    PubMed

    Elahi, P; Yılmaz, S; Akçaalan, O; Kalaycıoğlu, H; Oktem, B; Senel, C; Ilday, F Ö; Eken, K

    2012-08-01

    Thermal effects, which limit the average power, can be minimized by using low-doped, longer gain fibers, whereas the presence of nonlinear effects requires use of high-doped, shorter fibers to maximize the peak power. We propose the use of varying doping levels along the gain fiber to circumvent these opposing requirements. By analogy to dispersion management and nonlinearity management, we refer to this scheme as doping management. As a practical first implementation, we report on the development of a fiber laser-amplifier system, the last stage of which has a hybrid gain fiber composed of high-doped and low-doped Yb fibers. The amplifier generates 100 W at 100 MHz with pulse energy of 1 μJ. The seed source is a passively mode-locked fiber oscillator operating in the all-normal-dispersion regime. The amplifier comprises three stages, which are all-fiber-integrated, delivering 13 ps pulses at full power. By optionally placing a grating compressor after the first stage amplifier, chirp of the seed pulses can be controlled, which allows an extra degree of freedom in the interplay between dispersion and self-phase modulation. This way, the laser delivers 4.5 ps pulses with ~200 kW peak power directly from fiber, without using external pulse compression.

  10. Development of modular scalable pulsed power systems for high power magnetized plasma experiments

    NASA Astrophysics Data System (ADS)

    Bean, I. A.; Weber, T. E.; Adams, C. S.; Henderson, B. R.; Klim, A. J.

    2017-10-01

    New pulsed power switches and trigger drivers are being developed in order to explore higher energy regimes in the Magnetic Shock Experiment (MSX) at Los Alamos National Laboratory. To achieve the required plasma velocities, high-power (approx. 100 kV, 100s of kA), high charge transfer (approx. 1 C), low-jitter (few ns) gas switches are needed. A study has been conducted on the effects of various electrode geometries and materials, dielectric media, and triggering strategies; resulting in the design of a low-inductance annular field-distortion switch, optimized for use with dry air at 90 psig, and triggered by a low-jitter, rapid rise-time solid-state Linear Transformer Driver. The switch geometry and electrical characteristics are designed to be compatible with Syllac style capacitors, and are intended to be deployed in modular configurations. The scalable nature of this approach will enable the rapid design and implementation of a wide variety of high-power magnetized plasma experiments. This work is supported by the U.S. Department of Energy, National Nuclear Security Administration. Approved for unlimited release, LA-UR-17-2578.

  11. Pulse power 350 V nickel-metal hydride battery power-D-005-00181

    NASA Astrophysics Data System (ADS)

    Eskra, Michael D.; Ralston, Paula; Salkind, Alvin; Plivelich, Robert F.

    Energy-storage devices are needed for applications requiring very high-power over short periods of time. Such devices have various military (rail guns, electromagnetic launchers, and DEW) and commercial applications, such as hybrid electric vehicles, vehicle starting (SLI), and utility peak shaving. The storage and delivery of high levels of burst power can be achieved with a capacitor, flywheel, or rechargeable battery. In order to reduce the weight and volume of many systems they must contain advanced state-of-the-art electrochemical or electromechanical power sources. There is an opportunity and a need to develop energy-storage devices that have improved high-power characteristics compared to existing ultra capacitors, flywheels or rechargeable batteries. Electro Energy, Inc. has been engaged in the development of bipolar nickel-metal hydride batteries, which may fulfil the requirements of some of these applications. This paper describes a module rated at 300 V (255 cells) (6 Ah). The volume of the module is 23 L and the mass is 56 kg. The module is designed to deliver 50 kW pulses of 10 s duration at 50% state-of-charge. Details of the mechanical design of the module, safety considerations, along with the results of initial electrical characterization testing by the customer will be discussed. Some discussion of the possibilities for design optimization is also included.

  12. Dynamic Computed Tomographic Features of Adult Renal Cell Carcinoma Associated With Xp11.2 Translocation/TFE3 Gene Fusions: Comparison With Clear Cell Renal Cell Carcinoma.

    PubMed

    He, Jian; Gan, Weidong; Liu, Song; Zhou, Kefeng; Zhang, Gutian; Guo, Hongqian; Zhu, Bin

    2015-01-01

    To investigate the dynamic contrast-enhanced computed tomography (CT) characteristics of renal cell carcinoma associated with Xp11.2 translocation and TFE gene fusion (Xp11.2 RCC) by comparison with clear cell renal cell carcinoma (CCRCC). Dynamic contrast-enhanced CT images and clinical and pathological records of 20 adult patients with Xp11.2 RCC confirmed by TFE3 immunohistochemical and fluorescence in situ hybridization assay were retrospectively analyzed and compared with the findings of 21 contemporary CCRCCs. Renal cell carcinoma associated with Xp11.2 translocation and TFE gene fusions often occurred in young (30.6 ± 8.6 years) patients with hematuria (9/20). They presented as well-defined (17/20) cystic-solid (17/20) mass with hemorrhage (8/20) and circular/rim calcifications (6/20). Dynamic contrast-enhanced CT showed heterogeneous moderate prolonged enhancement. A tumor-to-cortex attenuation ratio in corticomedullary phase less than 0.62 gave a sensitivity of 90.0% and a specificity of 92.9% in differentiating Xp11.2 RCC from CCRCC (area under the receiver operating characteristic curve = 0.957, P < 0.001). Computed tomographic characteristics and dynamic contrast-enhanced patterns and index can differentiate Xp11.2 RCC from CCRCC.

  13. Large inverted repeats within Xp11.2 are present at the breakpoints of isodicentric X chromosomes in Turner syndrome.

    PubMed

    Scott, Stuart A; Cohen, Ninette; Brandt, Tracy; Warburton, Peter E; Edelmann, Lisa

    2010-09-01

    Turner syndrome (TS) results from whole or partial monosomy X and is mediated by haploinsufficiency of genes that normally escape X-inactivation. Although a 45,X karyotype is observed in half of all TS cases, the most frequent variant TS karyotype includes the isodicentric X chromosome alone [46,X,idic(X)(p11)] or as a mosaic [46,X,idic(X)(p11)/45,X]. Given the mechanism of idic(X)(p11) rearrangement is poorly understood and breakpoint sequence information is unknown, this study sought to investigate the molecular mechanism of idic(X)(p11) formation by determining their precise breakpoint intervals. Karyotype analysis and fluorescence in situ hybridization mapping of eight idic(X)(p11) cell lines and three unbalanced Xp11.2 translocation lines identified the majority of breakpoints within a 5 Mb region, from approximately 53 to 58 Mb, in Xp11.1-p11.22, clustering into four regions. To further refine the breakpoints, a high-resolution oligonucleotide microarray (average of approximately 350 bp) was designed and array-based comparative genomic hybridization (aCGH) was performed on all 11 idic(X)(p11) and Xp11.2 translocation lines. aCGH analyses identified all breakpoint regions, including an idic(X)(p11) line with two potential breakpoints, one breakpoint shared between two idic(X)(p11) lines and two Xp translocations that shared breakpoints with idic(X)(p11) lines. Four of the breakpoint regions included large inverted repeats composed of repetitive gene clusters and segmental duplications, which corresponded to regions of copy-number variation. These data indicate that the rearrangement sites on Xp11.2 that lead to isodicentric chromosome formation and translocations are probably not random and suggest that the complex repetitive architecture of this region predisposes it to rearrangements, some of which are recurrent.

  14. Chamber wall materials response to pulsed ions at power-plant level fluences

    NASA Astrophysics Data System (ADS)

    Renk, T. J.; Provencio, P. P.; Tanaka, T. J.; Olson, C. L.; Peterson, R. R.; Stolp, J. E.; Schroen, D. G.; Knowles, T. R.

    2005-12-01

    Candidate dry-wall materials for the reactor chambers of future laser-driven Inertial Fusion Energy (IFE) power plants have been exposed to ion pulses from RHEPP-1, located at Sandia National Laboratories. These pulses simulate the MeV-level ion pulses with fluences of up to 20 J/cm 2 that can be expected to impinge on the first wall of such future plants. Various forms of tungsten and tungsten alloy were subjected to up to 1600 pulses, usually while being heated to 600 °C. Other metals were exposed as well. Thresholds for roughening and material removal, and evolution of surface morphology were measured and compared with code predictions for materials response. Powder-metallurgy (PM) tungsten is observed to undergo surface roughening and subsurface crack formation that evolves over hundreds of pulses, and which can occur both below and above the melt threshold. This roughening is worse than for other metals, and worse than for either tungsten alloyed with rhenium (W25Re), or for CVD and single-crystal forms of tungsten. Carbon, particularly the form used in composite material, appears to suffer material loss well below its sublimation point. Some engineered materials were also investigated. It appears that some modification to PM tungsten is required for its successful use in a reactor environment.

  15. Optimization of Industrial Ozone Generation with Pulsed Power

    NASA Astrophysics Data System (ADS)

    Lopez, Jose; Guerrero, Daniel; Freilich, Alfred; Ramoino, Luca; Seton Hall University Team; Degremont Technologies-Ozonia Team

    2013-09-01

    Ozone (O3) is widely used for applications ranging from various industrial chemical synthesis processes to large-scale water treatment. The consequent surge in world-wide demand has brought about the requirement for ozone generation at the rate of several hundreds grams per kilowatt hour (g/kWh). For many years, ozone has been generated by means of dielectric barrier discharges (DBD), where a high-energy electric field between two electrodes separated by a dielectric and gap containing pure oxygen or air produce various microplasmas. The resultant microplasmas provide sufficient energy to dissociate the oxygen molecules while allowing the proper energetics channels for the formation of ozone. This presentation will review the current power schemes used for large-scale ozone generation and explore the use of high-voltage nanosecond pulses with reduced electric fields. The created microplasmas in a high reduced electric field are expected to be more efficient for ozone generation. This is confirmed with the current results of this work which observed that the efficiency of ozone generation increases by over eight time when the rise time and pulse duration are shortened. Department of Physics, South Orange, NJ, USA.

  16. Nucleation and Grain Refinement of 7A04 Aluminum Alloy Under a Low-Power Electromagnetic Pulse

    NASA Astrophysics Data System (ADS)

    Bai, Qingwei; Ma, Yonglin; Xing, Shuqing; Bao, Xinyu; Feng, Yanfei; Kang, Xiaolan

    2018-02-01

    The effects of a low-power electromagnetic pulse on the grain size and cooling curve of high-strength aluminum alloy 7A04 were investigated for various pulse duty cycles. This electromagnetic pulse treatment was found to effectively produce fine grains with globular crystals and a uniform microstructure for pulse duty cycles between 20 and 40%. The key factors that affected grain refinement under the electromagnetic pulse included the electromagnetic energy and the conversion frequency between \\varvec{B} and \\varvec{E} . The nucleation rate increased as the nucleation period was extended. A new kinetic condition of magnetic nucleation was explored by decreasing the critical Gibbs free energy in the electromagnetic pulse, which was more sensitive under low undercooling. In addition, the crystal orientation was controlled in such a solidification environment.

  17. Coherent Enhancement of 10 s Burst-Mode Ultraviolet Pulses at Megawatt Peak Power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abudureyimu, Reheman; Liu, Yun

    2017-01-01

    A doubly-resonant optical cavity and its locking technique have been developed to achieve coherent enhancement of 402.5-MHz, 50-ps, megawatt peak power ultraviolet (355 nm) laser pulses operating at a 10- s/10-Hz burst mode.

  18. Pulse stretcher

    DOEpatents

    Horton, J.A.

    1994-05-03

    Apparatus for increasing the length of a laser pulse to reduce its peak power without substantial loss in the average power of the pulse is disclosed. The apparatus uses a White cell having a plurality of optical delay paths of successively increasing number of passes between the field mirror and the objective mirrors. A pulse from a laser travels through a multi-leg reflective path between a beam splitter and a totally reflective mirror to the laser output. The laser pulse is also simultaneously injected through the beam splitter to the input mirrors of the optical delay paths. The pulses from the output mirrors of the optical delay paths go simultaneously to the laser output and to the input mirrors of the longer optical delay paths. The beam splitter is 50% reflective and 50% transmissive to provide equal attenuation of all of the pulses at the laser output. 6 figures.

  19. The Role of Pulsed Power in International Security and Counterterrorism

    DTIC Science & Technology

    2013-06-01

    penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE JUN 2003...2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE The Role Of Pulsed Power In International Security And Counterterrorism 5a...In spite of the international sanctions, the Third Reich enjoyed the second-largest industrial base on earth . In a number of technical disciplines

  20. [MRI findings of renal cell carcinoma associated with Xp11.2 translocations/TFE3 gene fusions].

    PubMed

    Zhong, Y; Wang, H Y; Chen, X; Guo, A T; Ma, L; Wang, Y W; Ye, H Y

    2016-09-06

    Objective: To analyze MRI findings of renal cell carcinoma associated with Xp11.2 translocation-TFE gene fusion(Xp11.2 RCC). Methods: MR imaging features of eleven patients with pathologically-proved Xp11.2 RCC were retrospectively analyzed from December 2008 to December 2015. The following MRI features of the lesions were analyzed in the study: location, maximal diameter, signal intensity, hemorrhage, necrosis, cystic change, enhancement features and metastasis. The data was analyzed by using t test. Results: Four men and seven women (mean age, 35.2 years; age range, 15-49 years) were included. Tumors occurred in the right kidney in 5 cases and the left kidney in 6 cases. On T 1 WI tumors showed heterogeneously hypo-intensity and iso-intensity, hyper-intensity in 10 cases, 1 cases, respectively. On T 2 WI tumors showed heterogeneously slight hypo-intensity, heterogeneously slight hyper-intensity and hyper-intensity in 6 cases, 4 cases, 1 case, respectively. On DWI tumors showed hyper-intensity and heterogeneously slight hype-intensity in 2 cases, 9 cases, respectively. ADC value of the tumors were statistically significant lower than that of renal cortex(×10 -3 mm 2 /s)(1.35±0.20 vs 2.09±0.11, P <0.05). Imaging findings were suggestive of hemorrhage( n =4) or necrosis ( n =1) or cystic change ( n =6) or lipid( n =1) in the tumors. On dynamic contrast-enhanced imaging, tumors showed lower signal intensity change (96%±93%, 110%±86% and 103%±46%, respectively) than did renal cortex (285%±109%, 254%±97% and 225%±90%, respectively) ( P <0.05). Tumor capsule showed in 7 cases. Enlarged lymph node was found in renal hilum in one case. Conclusion: MRI findings may show characteristic features of Xp11.2 RCC combined with patients' age and assist in preoperative correct diagnosis.

  1. Renal Cell Carcinoma Associated with Xp11.2 Translocation/TFE3 Gene Fusions: Clinical Features, Treatments and Prognosis.

    PubMed

    Liu, Ning; Wang, Zhen; Gan, Weidong; Xiong, Lei; Miao, Baolei; Chen, Xiancheng; Guo, Hongqian; Li, Dongmei

    2016-01-01

    To investigate the clinical characteristics, treatments and prognosis of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 tRCC), the epidemiological features and treatment results of 34 cases of Xp11.2 tRCC, which were diagnosed by immunohistochemistry staining of TFE3 and fluorescence in situ hybridization at our center, were retrospectively reviewed. The 34 patients included 21 females and 13 males aged 3 to 64 years (median age: 27 years). Four patients were children or adolescents (<18 years of age), and 26 patients were young or middle-aged adults (18-45 years). Radical nephrectomy was performed on 25 patients. Laparoscopic nephron-sparing surgery was performed on 9 patients who presented with an isolated mass with a small diameter (<7 cm) and well-defined boundary on computed tomography imaging. Postoperative staging showed that 25 cases (73.53%) were at stage I/II, while 9 cases (26.47%) were at stage III/IV. All stage I/II patients received a favorable prognosis with a three-year overall survival rate of 100%, including the patients who underwent laparoscopic nephron-sparing surgery. With the exception of 2 children, the other 7 stage III/IV patients died or developed recurrence with a median follow-up of 29 months. On univariate analysis, maximum diameter, adjuvant treatment, TNM stage, lymph node metastasis, inferior vena cava tumor thrombosis and tumor boundary were identified as statistically significant factors impacting survival (P<0.05). Multivariate analysis indicated that TNM stage and inferior vena cava tumor thrombosis were independent prognostic factors (P<0.05). In conclusion, Xp11.2 tRCC is a rare subtype of renal cell carcinoma that mainly occurs in young females. Nephron-sparing surgery was confirmed effective preliminarily in the treatment of small Xp11.2 tRCCs with clear rims. Advanced TNM stage and inferior vena cava tumor thrombosis were associated with poor prognosis.

  2. Renal Cell Carcinoma Associated with Xp11.2 Translocation/TFE3 Gene Fusions: Clinical Features, Treatments and Prognosis

    PubMed Central

    Gan, Weidong; Xiong, Lei; Miao, Baolei; Chen, Xiancheng; Guo, Hongqian; Li, Dongmei

    2016-01-01

    To investigate the clinical characteristics, treatments and prognosis of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 tRCC), the epidemiological features and treatment results of 34 cases of Xp11.2 tRCC, which were diagnosed by immunohistochemistry staining of TFE3 and fluorescence in situ hybridization at our center, were retrospectively reviewed. The 34 patients included 21 females and 13 males aged 3 to 64 years (median age: 27 years). Four patients were children or adolescents (<18 years of age), and 26 patients were young or middle-aged adults (18–45 years). Radical nephrectomy was performed on 25 patients. Laparoscopic nephron-sparing surgery was performed on 9 patients who presented with an isolated mass with a small diameter (<7 cm) and well-defined boundary on computed tomography imaging. Postoperative staging showed that 25 cases (73.53%) were at stage I/II, while 9 cases (26.47%) were at stage III/IV. All stage I/II patients received a favorable prognosis with a three-year overall survival rate of 100%, including the patients who underwent laparoscopic nephron-sparing surgery. With the exception of 2 children, the other 7 stage III/IV patients died or developed recurrence with a median follow-up of 29 months. On univariate analysis, maximum diameter, adjuvant treatment, TNM stage, lymph node metastasis, inferior vena cava tumor thrombosis and tumor boundary were identified as statistically significant factors impacting survival (P<0.05). Multivariate analysis indicated that TNM stage and inferior vena cava tumor thrombosis were independent prognostic factors (P<0.05). In conclusion, Xp11.2 tRCC is a rare subtype of renal cell carcinoma that mainly occurs in young females. Nephron-sparing surgery was confirmed effective preliminarily in the treatment of small Xp11.2 tRCCs with clear rims. Advanced TNM stage and inferior vena cava tumor thrombosis were associated with poor prognosis. PMID:27893792

  3. A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device.

    PubMed

    Srivastava, P K; Singh, S K; Sanyasi, A K; Awasthi, L M; Mattoo, S K

    2016-07-01

    This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.

  4. A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Srivastava, P. K., E-mail: pkumar@ipr.res.in; Singh, S. K.; Sanyasi, A. K.

    This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltagemore » protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.« less

  5. Mode-locked long fibre master oscillator with intra-cavity power management and pulse energy > 12 µJ.

    PubMed

    Ivanenko, Alexey; Kobtsev, Sergey; Smirnov, Sergey; Kemmer, Anna

    2016-03-21

    Combined lengthening of the cavity of a passive mode-locked fibre master oscillator and implementation of a new concept of intra-cavity power management led to achievement of a record-high pulse energy directly at the output of the mode-locked fibre master oscillator (without any subsequent amplification) exceeding 12 µJ. Output powers at the level of > 12 µJ obtainable from a long-cavity mode-locked fibre master oscillator open new possibilities of application of all pulse types that can be generated in such oscillators.

  6. Generation of spectrally-stable continuous-wave emission and ns pulses at 800 nm and 975 nm with a peak power of 4 W using a distributed Bragg reflector laser and a ridge-waveguide power amplifier

    NASA Astrophysics Data System (ADS)

    Klehr, A.; Wenzel, H.; Fricke, J.; Bugge, F.; Liero, A.; Hoffmann, Th.; Erbert, G.; Tränkle, G.

    2015-03-01

    Semiconductor based sources which emit high-power spectrally stable nearly diffraction-limited optical pulses in the nanosecond range are ideally suited for a lot of applications, such as free-space communications, metrology, material processing, seed lasers for fiber or solid state lasers, spectroscopy, LIDAR and frequency doubling. Detailed experimental investigations of 975 nm and 800 nm diode lasers based on master oscillator power amplifier (MOPA) light sources are presented. The MOPA systems consist of distributed Bragg reflector lasers (DBR) as master oscillators driven by a constant current and ridge waveguide power amplifiers which can be driven DC and by current pulses. In pulse regime the amplifiers modulated with rectangular current pulses of about 5 ns width and a repetition frequency of 200 kHz act as optical gates, converting the continuous wave (CW) input beam emitted by the DBR lasers into a train of short optical pulses which are amplified. With these experimental MOPA arrangements no relaxation oscillations in the pulse power occur. With a seed power of about 5 mW at a wavelength of 973 nm output powers behind the amplifier of about 1 W under DC injection and 4 W under pulsed operation, corresponding to amplification factors of 200 (amplifier gain 23 dB) and 800 (gain 29 dB) respectively, are reached. At 800 nm a CW power of 1 W is obtained for a seed power of 40 mW. The optical spectra of the emission of the amplifiers exhibit a single peak at a constant wavelength with a line width < 10 pm in the whole investigated current ranges. The ratios between laser and ASE levels were > 50 dB. The output beams are nearly diffraction limited with beam propagation ratios M2lat ~ 1.1 and M2ver ~ 1.2 up to 4 W pulse power.

  7. Frequency doubled high-power disk lasers in pulsed and continuous-wave operation

    NASA Astrophysics Data System (ADS)

    Weiler, Sascha; Hangst, Alexander; Stolzenburg, Christian; Zawischa, Ivo; Sutter, Dirk; Killi, Alexander; Kalfhues, Steffen; Kriegshaeuser, Uwe; Holzer, Marco; Havrilla, David

    2012-03-01

    The disk laser with multi-kW output power in infrared cw operation is widely used in today's manufacturing, primarily in the automotive industry. The disk technology combines high power (average and/or peak power), excellent beam quality, high efficiency and high reliability with low investment and operating costs. Additionally, the disk laser is ideally suited for frequency conversion due to its polarized output with negligible depolarization losses. Laser light in the green spectral range (~515 nm) can be created with a nonlinear crystal. Pulsed disk lasers with green output of well above 50 W (extracavity doubling) in the ps regime and several hundreds of Watts in the ns regime with intracavity doubling are already commercially available whereas intracavity doubled disk lasers in continuous wave operation with greater than 250 W output are in test phase. In both operating modes (pulsed and cw) the frequency doubled disk laser offers advantages in existing and new applications. Copper welding for example is said to show much higher process reliability with green laser light due to its higher absorption in comparison to the infrared. This improvement has the potential to be very beneficial for the automotive industry's move to electrical vehicles which requires reliable high-volume welding of copper as a major task for electro motors, batteries, etc.

  8. Unstable and multiple pulsing can be invisible to ultrashort pulse measurement techniques

    DOE PAGES

    Rhodes, Michelle A.; Guang, Zhe; Trebino, Rick

    2016-12-29

    Here, multiple pulsing occurs in most ultrashort-pulse laser systems when pumped at excessively high powers, and small fluctuations in pump power in certain regimes can cause unusual variations in the temporal separations of sub-pulses. Unfortunately, the ability of modern intensity-and-phase pulse measurement techniques to measure such unstable multi-pulsing has not been studied. Here we report calculations and simulations finding that allowing variations in just the relative phase of a satellite pulse causes the second pulse to completely disappear from a spectral interferometry for direct electric field reconstruction (SPIDER) measurement. We find that, although neither frequency-resolved optical gating (FROG) nor autocorrelationmore » can determine the precise properties of satellite pulses due to the presence of instability, they always succeed in, at least, seeing the satellite pulses. Also, additional post-processing of the measured FROG trace can determine the correct approximate relative height of the satellite pulse and definitively indicate the presence of unstable multiple-pulsing.« less

  9. Unstable and multiple pulsing can be invisible to ultrashort pulse measurement techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rhodes, Michelle A.; Guang, Zhe; Trebino, Rick

    Here, multiple pulsing occurs in most ultrashort-pulse laser systems when pumped at excessively high powers, and small fluctuations in pump power in certain regimes can cause unusual variations in the temporal separations of sub-pulses. Unfortunately, the ability of modern intensity-and-phase pulse measurement techniques to measure such unstable multi-pulsing has not been studied. Here we report calculations and simulations finding that allowing variations in just the relative phase of a satellite pulse causes the second pulse to completely disappear from a spectral interferometry for direct electric field reconstruction (SPIDER) measurement. We find that, although neither frequency-resolved optical gating (FROG) nor autocorrelationmore » can determine the precise properties of satellite pulses due to the presence of instability, they always succeed in, at least, seeing the satellite pulses. Also, additional post-processing of the measured FROG trace can determine the correct approximate relative height of the satellite pulse and definitively indicate the presence of unstable multiple-pulsing.« less

  10. Report: Passaic Valley Sewerage Commissioners – Unallowable Costs Claimed Under EPA Grant XP98237601

    EPA Pesticide Factsheets

    Report #08-2-0226, August 6, 2008. The grantee claimed $2,385,634 for pre-award costs under Grant XP98237601 that were incurred prior to the grant award and thus were unallowable under the grant administrative conditions and OMB Circular A-87.

  11. 175 fs-long pulses from a high-power single-mode Er-doped fiber laser at 1550 nm

    NASA Astrophysics Data System (ADS)

    Elahi, Parviz; Kalaycıoğlu, Hamit; Li, Huihui; Akçaalan, Önder; Ilday, F. Ömer

    2017-11-01

    Development of Er-doped ultrafast lasers have lagged behind the corresponding developments in Yb- and Tm-doped lasers, in particular, fiber lasers. Various applications benefit from operation at a central wavelength of 1.5 μm and its second harmonic, including emerging applications such as 3D processing of silicon and 3D printing based on two-photon polymerization. We report a simple, robust fiber master oscillator power amplifier operating at 1.55 μm, implementing chirp pulse amplification using single-mode fibers for diffraction-limited beam quality. The laser generates 80 nJ pulses at a repetition rate of 43 MHz, corresponding to an average power of 3.5 W, which can be compressed down to 175 fs. The generation of short pulses was achieved using a design which is guided by numerical simulations of pulse propagation and amplification and manages to overturn gain narrowing with self-phase modulation, without invoking excessive Raman scattering processes. The seed source for the two-stage amplifier is a dispersion-managed passively mode-locked oscillator, which generates a ∼40 nm-wide spectrum and 1.7-ps linearly chirped pulses.

  12. LN2-free Operation of the MEG Liquid Xenon Calorimeter by using a High-power Pulse Tube Cryocooler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haruyama, T.; Kasami, K.; Nishiguchi, H.

    2006-04-27

    A high-power coaxial pulse tube cryocooler, originally developed in KEK and technology-transferred to Iwatani Industrial Gases Corp (IIGC), has been installed in a large liquid xenon calorimeter to evaluate liquid nitrogen-free (LN2-free) operation of the rare {mu}-particle decay experiment (MEG). Features of this pulse tube cryocooler include the cold-end heat exchanger, designed with sufficient surface area to ensure high-power cooling, and a cylindrical regenerator placed inside the pulse tube giving compact design and ease of fabrication. This production-level cryocooler provides a cooling power of {approx}200 W at 165 K, using a 6 kW Gifford-McMahon (GM)-type compressor. The paper describes themore » detailed configuration of the cryocooler, and the results of the continuous LN2-free operation of the large prototype liquid xenon calorimeter, which ran for more than 40 days without problems.« less

  13. Linear transformer driver for pulse generation

    DOEpatents

    Kim, Alexander A; Mazarakis, Michael G; Sinebryukhov, Vadim A; Volkov, Sergey N; Kondratiev, Sergey S; Alexeenko, Vitaly M; Bayol, Frederic; Demol, Gauthier; Stygar, William A

    2015-04-07

    A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first power delivery module that includes a first charge storage devices and a first switch. The first power delivery module sends a first energy in the form of a first pulse to the load. The linear transformer driver also includes a second power delivery module including a second charge storage device and a second switch. The second power delivery module sends a second energy in the form of a second pulse to the load. The second pulse has a frequency that is approximately three times the frequency of the first pulse. The at least one ferrite ring is positioned to force the first pulse and the second pulse to the load by temporarily isolating the first pulse and the second pulse from an electrical ground.

  14. Review of renal carcinoma associated with Xp11.2 translocations/TFE3 gene fusions with focus on pathobiological aspect.

    PubMed

    Kuroda, Naoto; Mikami, Shuji; Pan, Chin-Chen; Cohen, Ronald J; Hes, Ondrej; Michal, Michal; Nagashima, Yoji; Tanaka, Yukichi; Inoue, Keiji; Shuin, Taro; Lee, Gang-Hong

    2012-02-01

    The concept of Xp11.2 renal cell carcinoma (RCC) was recently established as a tumor affecting 15% of RCC patients <45 years. Many patients present with advanced stage with frequent lymph node metastases. Histologically, Xp11.2 RCC is characterized by mixed papillary nested/alveolar growth pattern and tumor cells with clear and/or eosinophilic, voluminous cytoplasm. Neoplastic cells show intense nuclear immunoreactivity to TFE3, while focal immunostaining for melanocytic markers, including melanosome-associated antigen or Melan A in some cases, are also noted. Alpha smooth muscle actin and TFEB are consistently negative. Ultrastructurally, the ASPL-TFE3 RCC variant contains rhomboid crystals in the cytoplasm, similar to that observed in alveolar soft part sarcoma. The fusion of the TFE3 gene with several different genes, including ASPL(17q25), PRCC(1q21), PSF(1q34), NonO (Xq12) and CLTC (17q23) have been identified to date. The behavior of Xp11.2 RCC in children and young adults is considered as indolent even when diagnosed at advanced stage, including lymph node metastasis. However, Xp11.2 RCC in older patients behaves in a more aggressive fashion. Therapy includes nephrectomy with extended lymphadenectomy. There may be a role for new protease inhibitors in advanced inoperable disease. Further research is required to correlate clinical behavior with the expanding genetic spectrum of this tumor, and to establish standard therapy protocols for primary and metastatic lesions.

  15. Harmonic generation with a dual frequency pulse.

    PubMed

    Keravnou, Christina P; Averkiou, Michalakis A

    2014-05-01

    Nonlinear imaging was implemented in commercial ultrasound systems over the last 15 years offering major advantages in many clinical applications. In this work, pulsing schemes coupled with a dual frequency pulse are presented. The pulsing schemes considered were pulse inversion, power modulation, and power modulated pulse inversion. The pulse contains a fundamental frequency f and a specified amount of its second harmonic 2f. The advantages and limitations of this method were evaluated with both acoustic measurements of harmonic generation and theoretical simulations based on the KZK equation. The use of two frequencies in a pulse results in the generation of the sum and difference frequency components in addition to the other harmonic components. While with single frequency pulses, only power modulation and power modulated pulse inversion contained odd harmonic components, with the dual frequency pulse, pulse inversion now also contains odd harmonic components.

  16. An ultra-low-power pulse oximeter implemented with an energy-efficient transimpedance amplifier.

    PubMed

    Tavakoli, M; Turicchia, L; Sarpeshkar, R

    2010-02-01

    Pulse oximeters are ubiquitous in modern medicine to noninvasively measure the percentage of oxygenated hemoglobin in a patient's blood by comparing the transmission characteristics of red and infrared light-emitting diode light through the patient's finger with a photoreceptor. We present an analog single-chip pulse oximeter with 4.8-mW total power dissipation, which is an order of magnitude below our measurements on commercial implementations. The majority of this power reduction is due to the use of a novel logarithmic transimpedance amplifier with inherent contrast sensitivity, distributed amplification, unilateralization, and automatic loop gain control. The transimpedance amplifier, together with a photodiode current source, form a high-performance photoreceptor with characteristics similar to those found in nature, which allows LED power to be reduced. Therefore, our oximeter is well suited for portable medical applications, such as continuous home-care monitoring for elderly or chronic patients, emergency patient transport, remote soldier monitoring, and wireless medical sensing. Furthermore, our design obviates the need for an A-to-D and digital signal processor and leads to a small single-chip solution. We outline how extensions of our work could lead to submilliwatt oximeters.

  17. Autism in Two Females with Duplications Involving Xp11.22-p11.23

    ERIC Educational Resources Information Center

    Edens, Anna C.; Lyons, Michael J.; Duron, Reyna M.; DuPont, Barbara R.; Holden, Kenton R.

    2011-01-01

    We present two phenotypically similar females with Xp duplication who have autism and epilepsy. Case 1 is a 14-year-old Honduran female with autism and medically refractory complex partial, secondarily generalized epilepsy. Case 2 is a 3-year-old Austrian female with autism and medically refractory complex partial epilepsy. Both patients also…

  18. Unassisted Water Splitting Using a GaSb xP (1- x ) Photoanode

    DOE PAGES

    Martinez-Garcia, Alejandro; Russell, Harry B.; Paxton, William; ...

    2018-02-21

    Here in this work, unbiased water splitting with 2% solar-to-hydrogen efficiency under AM 1.5 G illumination using new materials based on GaSb 0.03P 0.97 alloy is reported. Freestanding GaSb xP 1-x is grown using halide vapor phase epitaxy. The native conductivity type of the alloy is modified by silicon doping, resulting in an open-circuit potential (OCP) of 750 mV, photocurrents of 7 mA cm -2 at 10 sun illumination, and corrosion resistance in an aqueous acidic environment. Alloying GaP with Sb at 3 at% improves the absorption of high-energy photons above 2.68 eV compared to pure GaP material. Electrochemical Impedancemore » Spectroscopy and illuminated OCP measurements show that the conduction band of GaSb xP 1-x is at -0.55 V versus RHE irrespective of the Sb concentration, while photocurrent spectroscopy indicates that only radiation with photon energies greater than 2.68 eV generate mobile and extractable charges, thus suggesting that the higher-laying conduction bands in the Γ 1 valley of the alloys are responsible for exciton generation.« less

  19. Unassisted Water Splitting Using a GaSb xP (1- x ) Photoanode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez-Garcia, Alejandro; Russell, Harry B.; Paxton, William

    Here in this work, unbiased water splitting with 2% solar-to-hydrogen efficiency under AM 1.5 G illumination using new materials based on GaSb 0.03P 0.97 alloy is reported. Freestanding GaSb xP 1-x is grown using halide vapor phase epitaxy. The native conductivity type of the alloy is modified by silicon doping, resulting in an open-circuit potential (OCP) of 750 mV, photocurrents of 7 mA cm -2 at 10 sun illumination, and corrosion resistance in an aqueous acidic environment. Alloying GaP with Sb at 3 at% improves the absorption of high-energy photons above 2.68 eV compared to pure GaP material. Electrochemical Impedancemore » Spectroscopy and illuminated OCP measurements show that the conduction band of GaSb xP 1-x is at -0.55 V versus RHE irrespective of the Sb concentration, while photocurrent spectroscopy indicates that only radiation with photon energies greater than 2.68 eV generate mobile and extractable charges, thus suggesting that the higher-laying conduction bands in the Γ 1 valley of the alloys are responsible for exciton generation.« less

  20. Specifics of Pulsed Arc Welding Power Supply Performance Based On A Transistor Switch

    NASA Astrophysics Data System (ADS)

    Krampit, N. Yu; Kust, T. S.; Krampit, M. A.

    2016-08-01

    Specifics of designing a pulsed arc welding power supply device are presented in the paper. Electronic components for managing large current was analyzed. Strengths and shortcomings of power supply circuits based on thyristor, bipolar transistor and MOSFET are outlined. As a base unit for pulsed arc welding was chosen MOSFET transistor, which is easy to manage. Measures to protect a transistor are given. As for the transistor control device is a microcontroller Arduino which has a low cost and adequate performance of the work. Bead transfer principle is to change the voltage on the arc in the formation of beads on the wire end. Microcontroller controls transistor when the arc voltage reaches the threshold voltage. Thus there is a separation and transfer of beads without splashing. Control strategies tested on a real device and presented. The error in the operation of the device is less than 25 us, it can be used controlling drop transfer at high frequencies (up to 1300 Hz).

  1. High-throughput machining using a high-average power ultrashort pulse laser and high-speed polygon scanner

    NASA Astrophysics Data System (ADS)

    Schille, Joerg; Schneider, Lutz; Streek, André; Kloetzer, Sascha; Loeschner, Udo

    2016-09-01

    High-throughput ultrashort pulse laser machining is investigated on various industrial grade metals (aluminum, copper, and stainless steel) and Al2O3 ceramic at unprecedented processing speeds. This is achieved by using a high-average power picosecond laser in conjunction with a unique, in-house developed polygon mirror-based biaxial scanning system. Therefore, different concepts of polygon scanners are engineered and tested to find the best architecture for high-speed and precision laser beam scanning. In order to identify the optimum conditions for efficient processing when using high-average laser powers, the depths of cavities made in the samples by varying the processing parameter settings are analyzed and, from the results obtained, the characteristic removal values are specified. For overlapping pulses of optimum fluence, the removal rate is as high as 27.8 mm3/min for aluminum, 21.4 mm3/min for copper, 15.3 mm3/min for stainless steel, and 129.1 mm3/min for Al2O3, when a laser beam of 187 W average laser powers irradiates. On stainless steel, it is demonstrated that the removal rate increases to 23.3 mm3/min when the laser beam is very fast moving. This is thanks to the low pulse overlap as achieved with 800 m/s beam deflection speed; thus, laser beam shielding can be avoided even when irradiating high-repetitive 20-MHz pulses.

  2. Development of a YAC contig covering the minimal region of a CSNB1 locus in Xp11

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boycott, K.M.; Gratton, K.J.; Moore, B.J.

    1994-09-01

    X-linked congenital stationary night blindness (CSNB1) is an eye disorder that includes impairment of night vision, reduced visual acuity and, in some cases, myopia and congenital nystagmus. Electroretinography reveals a marked reduction of the b-wave in affected individuals suggesting that X-linked CSNB is due to a molecular defect in the bipolar layer of the retina. Based on our studies of a large four generation family with X-linked CSNB, a CSNB1 locus was mapped to a 4-5 cM region at Xp11.23-Xp11.22 bounded telomerically by DXS426 and centromerically by DXS988. Using a panel of radiation and conventional somatic cell hybrids, a detailedmore » map of new and published STSs has been generated for the minimal region of CSNB1. PCR primer pairs for STSs has been generated for the minimal region of CSNB1. PCR primer pairs for twenty-five STSs, including eleven end-clones, were used to isolate YAC clones from CEPH, mega-CEPH, and X chromosome-specific YAC libraries. In total, fifty-two YACs were characterized for STS overlaps and assembled to provide a minimum of 3 Mb of physical coverage in the region between DXS426 and DXS988. Five gaps proximal to SYP are still to be closed. Our physical map suggests the following gene order: Xpter-OTAL1-GF1-DXS1011E-MG81-HUMCRAS2P-SYP-Xcen. STS analysis of the YACs revealed three subregions of the physical map which appear to be particularly susceptible to internal deletions and end-clone analysis demonstrated chimerism in six of seventeen YACs. A physical map of Xp11.23-Xp11.22 will provide a resource for the isolation of candidate genes for the X-linked CSNB gene which maps to this region.« less

  3. Gas breakdown driven by L band short-pulse high-power microwave

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang Yiming; Yuan Chengwei; Qian Baoliang

    2012-12-15

    High power microwave (HPM) driven gas breakdown is a major factor in limiting the radiation and transmission of HPM. A method that HPM driven gas breakdown could be obtained by changing the aperture of horn antenna is studied in this paper. Changing the effective aperture of horn antenna can adjust the electric field in near field zone, leading to gas breakdown. With this method, measurements of air and SF{sub 6} breakdowns are carried out on a magnetically insulated transmission-line oscillators, which is capable of generating HPM with pulse duration of 30 ns, and frequency of 1.74 GHz. The typical breakdownmore » waveforms of air and SF{sub 6} are presented. Besides, the breakdown field strengths of the two gases are derived at different pressures. It is found that the effects of air and SF{sub 6} breakdown on the transmission of HPM are different: air breakdown mainly shortens the pulse width of HPM while SF{sub 6} breakdown mainly reduces the peak output power of HPM. The electric field threshold of SF{sub 6} is about 2.4 times larger than that of air. These differences suggest that gas properties have a great effect on the transmission characteristic of HPM in gases.« less

  4. Nephron-sparing surgery in the treatment of pediatric renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions.

    PubMed

    Liu, Chao; Zhang, Weiping; Song, Hongcheng

    2017-09-01

    To investigate the safety and efficacy of nephron-sparing surgery (NSS) in the treatment of pediatric Xp11.2 translocation renal cell carcinoma (RCC). Clinical characteristics of 9 RCC children (7 males and 2 females) with Xp11.2 translocation who received NSS between January 1973 and December 2015 were retrospectively analyzed. The mean age was 7.8years (range: 4.5-13.5years). Xp11.2 translocation RCC was found in the left side in 4 patients and right in 5. 3 tumors were located in the upper pole of the kidney, 1 in the middle dorsal, 1 in the middle ventral and 4 in the lower pole. RCC presented with painless gross hematuria in 4 patients, abdominal mass in 1, and as an incidental finding by ultrasound examination in 4 patients. The mean course of hematuria was 3months (range: 1-7months). The mean tumor diameters were 3.7cm (range: 2.2-6.9cm). All the patients received NSS with open transperitoneal approach. The mean operative time and estimated blood loss were 115min and 40ml, respectively. The time of renal pedicle clamping was 19-25min (mean: 21.5min). No complications (such as leakage of urine, prolonged drainage or secondary bleeding) were noted. No patients experienced local recurrence during the mean of 50.1-month follow-up (range: 13-117months). Intravenous urography (IVU) or contrast-enhanced CT was conducted at 6months after surgery which showed favorable kidney function in all patients. Xp11.2 translocation RCC is a predominant pathological but biologically inert type of pediatric RCC. For Xp11.2 translocation RCC sized <4-7cm in diameter and located in one pole, NSS is safe and feasible. Treatment Studies, LEVEL IV. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Symmetry-Breaking Transitions in RECuAs 2-xP x (RE=Sm, Gd, Ho, and Er)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mozharivskyj, Yurij

    Structural changes resulting in lower symmetries can be understood in terms of electronic instabilities and Coulomb interactions. The interplay of these two interrelated factors is complicated and difficult to analyze. The RECuAs 2-xP x phases, because of the variation in the chemical content (As/P substitution), allow, with the aid of band structures, Madelung energies and Landau theory, a partial unraveling of the forces important in the symmetry-breaking transitions in RECuAs 2-xP x (RE = Sm, Gd, Ho and Er). Distortions of the P layers in SmCu 1.15P 2, GdCuP 2.20 and ErCuP 2 are usefully thought of asmore » generalized Peierls distortions, i.e., they lower the electronic (and total) energy and lead to more stable structures. On the other hand, the P4/nmm → Pmmn transitions, which are observed in all studied arsenophosphide series and occur upon substitution of P for As, originate from the B1g vibrational mode and are structural adaptations to smaller P atoms. These transitions provide tighter atomic packing and better Coulomb interactions. Configurational contribution to the entropy becomes important in stabilizing the mixed occupancy in the RECuAs 2-xP x arsenophosphides. While geometric and electronic factors favor separation of the As and P atoms over two different crystallographic sites, configurational entropy stabilizes the As/P mixing on these two sites.;Progress in the research on RECuAs 2-xP x was dependent upon the ability of Landau theory to predict, explain and dismiss structural models and transitions. The space group Pmmn (arising from the B 1g vibrational mode) in all mixed arsenophosphides and the existence of these mixed arsenophosphides followed from the analysis of GdCuAs 2 and GdCuP 2, using Landau theory. The impossibility of obtaining the high-symmetry structure (P4/nmm) and the low symmetry structure (Pnmm) at the same temperature for the displacive continuous symmetry-breaking transition P4/ nmm → Pmmn led to the conclusion, later

  6. The light ion pulsed power induction accelerator for ETF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazarakis, M.G.; Olson, R.E.; Olson, C.L.

    1994-12-31

    Our Engineering Test Facility (ETF) driver concept is based on HERMES III and RHEPP technologies. Actually, it is a scaled-down version of the LMF design incorporating repetition rate capabilities of up to 10 Hz CW. The preconceptual design presented here provides 200-TW peak power to the ETF target during 10 ns, equal to 2-MJ total ion beam energy. Linear inductive voltage addition driving a self-magnetically insulated transmission line (MITL) is utilized to generate the 36-MV peak voltage needed for lithium ion beams. The {approximately} 3-MA ion current is achieved by utilizing many accelerating modules in parallel. Since the current permore » module is relatively modest ({approximately}300 kA), two-stage or one-stage extraction diodes can be utilized for the generation of singly charged lithium ions. The accelerating modules are arranged symmetrically around the fusion chamber in order to provide uniform irradiation onto the ETF target. In addition, the modules are fired in a programmed sequence in order to generate the optimum power pulse shape onto the target. This design utilizes RHEPP accelerator modules as the principal power source.« less

  7. Location of Dual Sites in E. coli FtsZ Important for Degradation by ClpXP; One at the C-Terminus and One in the Disordered Linker

    PubMed Central

    Camberg, Jodi L.; Viola, Marissa G.; Rea, Leslie; Hoskins, Joel R.; Wickner, Sue

    2014-01-01

    ClpXP is a two-component ATP-dependent protease that unfolds and degrades proteins bearing specific recognition signals. One substrate degraded by Escherichia coli ClpXP is FtsZ, an essential cell division protein. FtsZ forms polymers that assemble into a large ring-like structure, termed the Z-ring, during cell division at the site of constriction. The FtsZ monomer is composed of an N-terminal polymerization domain, an unstructured linker region and a C-terminal conserved region. To better understand substrate selection by ClpXP, we engineered FtsZ mutant proteins containing amino acid substitutions or deletions near the FtsZ C-terminus. We identified two discrete regions of FtsZ important for degradation of both FtsZ monomers and polymers by ClpXP in vitro. One region is located 30 residues away from the C-terminus in the unstructured linker region that connects the polymerization domain to the C-terminal region. The other region is near the FtsZ C-terminus and partially overlaps the recognition sites for several other FtsZ-interacting proteins, including MinC, ZipA and FtsA. Mutation of either region caused the protein to be more stable and mutation of both caused an additive effect, suggesting that both regions are important. We also observed that in vitro MinC inhibits degradation of FtsZ by ClpXP, suggesting that some of the same residues in the C-terminal site that are important for degradation by ClpXP are important for binding MinC. PMID:24722340

  8. Imprint cytologic features in renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion in an adult: a case report.

    PubMed

    Yamaguchi, Tadanori; Kuroda, Naoto; Imamura, Yoshiaki; Hes, Ondrej; Kawada, Takako; Nakayama, Keizou

    2009-01-01

    Adult-onset renal cell carcinoma (RCC) associated with Xp11.2 translocation/TFE3 gene fusion is a very rare tumor. To date, there are no reports on immunocytochemical study of the primary tumor. We describe such a case that we diagnosed by immunocytochemistry of imprint cytology material. A 46-year-old man was found to have a mass in the lower pole of the right kidney. Magnetic resonance imaging (MRI) T2-weighted images showed a hypointense area in the tumor, and papillary RCC was suspected. Imprint cytology showed tumor cells that were isolated or arranged in large or small papillary clusters. Irregularly shaped large oval nuclei, finely granular chromatin and a single large nucleolus were noted. Cytoplasm was abundant and admixed with clear and granular eosinophilic patterns and scattered large vacuolated cells. Almost all tumor cells diffusely expressed immunocytochemical reactivity to TFE3 protein. Hyaline nodules were observed in the stroma. Ultrastructurally, neoplastic cells contained rhomboid crystals identical to those of alveolar soft part sarcoma. The immunocytochemistry of TFE3 protein may be a powerful tool for accurate diagnosis when RCC associated with Xp11.2 translocation/TFE3 gene fusion is suspected by imprint cytology even in adult-onset cases, and cytotechnologists should accurately recognize cytologic findings of this tumor.

  9. The influence of magnetic fields on the wake field and stopping power of an ion-beam pulse in plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Xiao-ying; Zhang, Ya-ling; Duan, Wen-shan

    2015-09-15

    We performed two-dimensional particle-in-cell simulations to investigate how a magnetic field affects the wake field and stopping power of an ion-beam pulse moving in plasmas. The corresponding density of plasma electrons is investigated. At a weak magnetic field, the wakes exhibit typical V-shaped cone structures. As the magnetic field strengthens, the wakes spread and lose their typical V-shaped structures. At a sufficiently strong magnetic field, the wakes exhibit conversed V-shaped structures. Additionally, strengthening the magnetic field reduces the stopping power in regions of low and high beam density. However, the influence of the magnetic field becomes complicated in regions ofmore » moderate beam density. The stopping power increases in a weak magnetic field, but it decreases in a strong magnetic field. At high beam density and moderate magnetic field, two low-density channels of plasma electrons appear on both sides of the incident beam pulse trajectory. This is because electrons near the beam pulses will be attracted and move along with the beam pulses, while other electrons nearby are restricted by the magnetic field and cannot fill the gap.« less

  10. Pulse transmission receiver with higher-order time derivative pulse correlator

    DOEpatents

    Dress, Jr., William B.; Smith, Stephen F.

    2003-09-16

    Systems and methods for pulse-transmission low-power communication modes are disclosed. A pulse transmission receiver includes: a higher-order time derivative pulse correlator; a demodulation decoder coupled to the higher-order time derivative pulse correlator; a clock coupled to the demodulation decoder; and a pseudorandom polynomial generator coupled to both the higher-order time derivative pulse correlator and the clock. The systems and methods significantly reduce lower-frequency emissions from pulse transmission spread-spectrum communication modes, which reduces potentially harmful interference to existing radio frequency services and users and also simultaneously permit transmission of multiple data bits by utilizing specific pulse shapes.

  11. Characterization testing of Lockheed Martin high-power micro pulse tube cryocooler

    NASA Astrophysics Data System (ADS)

    McKinley, I. M.; Hummel, C. D.; Johnson, D. L.; Rodriguez, J. I.

    2017-12-01

    This paper describes the thermal vacuum, microphonics, magnetics, and radiation testing and results of a Lockheed Martin high-power micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 185 and 300 K. The cooler was driven with a Chroma 61602 AC power source for input powers ranging from 10 to 60 W and drive frequency between 115 and 140 Hz during thermal performance testing. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the microphonics of the cooler were measured with the cooler driven by Iris Technologies LCCE-2 and HP-LCCE drive electronics for input powers ranging from 10 to 60 W and drive frequency between 135 and 145 Hz. The exported forces were strongly dependent on input power while only weakly dependent on the drive frequency. Moreover, the exported force in the compressor axis was minimized by closed loop control with the HP-LCCE. The cooler also survived a 500 krad radiation dose while being continuously operated with 30 W of input power at 220 K heat rejection temperature in vacuum. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

  12. MiT translocation renal cell carcinomas: two subgroups of tumours with translocations involving 6p21 [t (6; 11)] and Xp11.2 [t (X;1 or X or 17)].

    PubMed

    Hora, Milan; Urge, Tomáš; Trávníček, Ivan; Ferda, Jiří; Chudáček, Zdeněk; Vaněček, Tomáš; Michal, Michal; Petersson, Fredrik; Kuroda, Naoto; Hes, Ondřej

    2014-01-01

    MiT translocation renal cell carcinomas (TRCC) predominantly occur in younger patients with only 25% of patients being over 40 years. TRCC contains two main subgroups with translocations involving 6p21 or Xp11.2. Herein we present 10 cases. Eight cases were treated at main author's institution (identified among 1653 (0.48%) cases of kidney tumours in adults). Two cases were retrieved from the Pilsen (CZ) Tumour Registry. Six cases were type Xp11.2 and four 6p21; 7 female, 3 male patients; Xp11.2 4:2, 6p21 3:1. The mean age 49 years (range: 21-80), 5 patients (50%) over 40 years. The mean age of the group with Xp11.2 TRCCs was 55 (median 51) and 6p21 41 (32) years. One female with a 6p21 tumour (24 years) underwent nephrectomy at 4 months of pregnancy. Stage (UICC, 7th ed. 2009) was 5xI, 3xIII, 2xIV. The mean size of tumour was 80 (40-165) mm. The mean follow-up was 33.2 (1-92) months. In patients with 6p21 tumours, one (25%) died after 3 months due to widely metastatic disease. In patients with Xp11.2 tumours, 3 (50%) succumbed due to metastatic disease (range 1-8 months). Three patients with Xp11.2 are alive at 7, 52 and 92 months of follow-up, were diagnosed at early stage (T1a). TRCCs were more common in females. Patient with 6p21 tumours were younger than those with Xp11.2. Both types have definitive malignant potential Type Xp11.2 seems to be a more aggressive neoplasm than 6p21. The case with metastatic 6p21 tumour is the 4th case described in the English literature.

  13. Thin Film Delamination Using a High Power Pulsed Laser Materials Interaction

    NASA Astrophysics Data System (ADS)

    Sherman, Bradley

    Thin films attached to substrates are only effective while the film is adhered to the substrate. When the film begins to spall the whole system can fail, thus knowing the working strength of the film substrate system is important when designing structures. Surface acoustic waves (SAWs) are suitable for characterization of thin film mechanical properties due to the confinement of their energy within a shallow depth from a material surface. In this project, we study the feasibility of inducing dynamic interfacial failure in thin films using surface waves generated by a high power pulsed laser. Surface acoustic waves are modeled using a finite element numerical code, where the ablative interaction between the pulsed laser and the incident film is modeled using equivalent surface mechanical stresses. The numerical results are validated using experimental results from a laser ultrasonic setup. Once validated the normal film-substrate interfacial stress can be extracted from the numerical code and tends to be in the mega-Pascal range. This study uses pulsed laser generation to produce SAW in various metallic thin film/substrate systems. Each system varies in its response based on its dispersive relationship and as such requires individualized numerical modeling to match the experimental data. In addition to pulsed SAW excitation using an ablative source, a constrained thermo-mechanical load produced by the ablation of a metal film under a polymer layer is explored to generate larger dynamic mechanical stresses. These stresses are sufficient to delaminate the thin film in a manner similar to a peel test. However, since the loading is produced by a pulsed laser source, it occurs at a much faster rate, limiting the influence of slower damage modes that are present in quasi-static loading. This approach is explored to predict the interfacial fracture toughness of weak thin film interfaces.

  14. Pulse stretcher

    DOEpatents

    Horton, James A.

    1994-01-01

    Apparatus (20) for increasing the length of a laser pulse to reduce its peak power without substantial loss in the average power of the pulse. The apparatus (20) uses a White cell (10) having a plurality of optical delay paths (18a-18d) of successively increasing number of passes between the field mirror (13) and the objective mirrors (11 and 12). A pulse (26) from a laser (27) travels through a multi-leg reflective path (28) between a beam splitter (21) and a totally reflective mirror (24) to the laser output (37). The laser pulse (26) is also simultaneously injected through the beam splitter (21) to the input mirrors (14a-14d) of the optical delay paths (18a-18d). The pulses from the output mirrors (16a-16d) of the optical delay paths (18a-18d) go simultaneously to the laser output (37) and to the input mirrors ( 14b-14d) of the longer optical delay paths. The beam splitter (21) is 50% reflective and 50% transmissive to provide equal attenuation of all of the pulses at the laser output (37).

  15. Giant-pulse Nd:YVO4 microchip laser with MW-level peak power by emission cross-sectional control.

    PubMed

    Kausas, Arvydas; Taira, Takunori

    2016-02-22

    We present a giant-pulse generation laser realized by the emission cross-section control of a gain medium in a passively Q-switched Nd:YVO4 microchip laser with a Cr4+:YAG saturable absorber. Up to 1.17 MW peak power and 1.03 mJ pulse energy were obtained with a 100 Hz repetition rate. By combining the Nd:YVO4 crystal with a Sapphire plate, lower temperature difference between a pump region in the gain crystal and a crystal holder was obtained which helped to keep the cavity in stability zone at elevated temperatures and allowed the achievement of the high peak power for this laser system.

  16. Loss Analysis of High Power Stirling-Type Pulse Tube Cryocooler

    NASA Astrophysics Data System (ADS)

    Nakano, K.; Hiratsuka, Y.

    2015-12-01

    For the purpose of cooling high-temperature superconductor (HTS) devices, such as superconductor motors, superconducting magnetic energy storage (SMES) and current fault limiters, cryocoolers should be compact in size, light-weight, and have high efficiency and reliability. In order to meet the demand of HTS devices world-wide, the cryocooler needs to have COP efficiency >0.1. We have developed a high power Stirling-type pulse tube cryocooler (SPTC) with an in-line expander. The experimental results were reported in June 2012[1]. The cooling capacity was 210 W at 77 K and the minimum temperature was 37 K when the compressor input power was 3.8 kW. Accordingly, the COP was about 0.055. To further improve the efficiency, the energy losses in the cryocooler were analyzed. The experimental results and the numerical calculation results are reported in this paper.

  17. Pulse Power Capability Of High Energy Density Capacitors Based on a New Dielectric Material

    NASA Technical Reports Server (NTRS)

    Winsor, Paul; Scholz, Tim; Hudis, Martin; Slenes, Kirk M.

    1999-01-01

    A new dielectric composite consisting of a polymer coated onto a high-density metallized Kraft has been developed for application in high energy density pulse power capacitors. The polymer coating is custom formulated for high dielectric constant and strength with minimum dielectric losses. The composite can be wound and processed using conventional wound film capacitor manufacturing equipment. This new system has the potential to achieve 2 to 3 J/cu cm whole capacitor energy density at voltage levels above 3.0 kV, and can maintain its mechanical properties to temperatures above 150 C. The technical and manufacturing development of the composite material and fabrication into capacitors are summarized in this paper. Energy discharge testing, including capacitance and charge-discharge efficiency at normal and elevated temperatures, as well as DC life testing were performed on capacitors manufactured using this material. TPL (Albuquerque, NM) has developed the material and Aerovox (New Bedford, MA) has used the material to build and test actual capacitors. The results of the testing will focus on pulse power applications specifically those found in electro-magnetic armor and guns, high power microwave sources and defibrillators.

  18. Discovery and identification of O, O-diethyl O-(4-(5-phenyl-4, 5-dihydroisoxazol-3-yl) phenyl) phosphorothioate (XP-1408) as a novel mode of action of organophosphorus insecticides.

    PubMed

    Zeng, Zhigang; Yan, Ying; Wang, Bingfeng; Liu, Niu; Xu, Hanhong

    2017-06-15

    Organophosphorus (OP) insecticides play an important role in pest control. Many OP insecticides have been removed from the market because of their high toxicity to humans. We designed and synthesized a new OP insecticide with the goal of providing a low cost, and less toxic insecticide. The mode of action of O, O-diethyl O-(4-(5-phenyl-4, 5-dihydroisoxazol-3-yl) phenyl) phosphorothioate (XP-1408) was studied in Drosophila melanogaster. Bioassays showed that XP-1408 at a concentration of 50 mg/L delayed larval development. Molecular docking into Drosophila acetylcholinesterase (AChE) and voltage-gated sodium channels suggested that XP-1408 fitted into their active sites and could be inhibitory. Whole-cell patch clamp recordings indicated that XP-1408 exhibited synergistic effects involving the inhibition of cholinergic synaptic transmission and blockage of voltage-gated potassium (K v ) channels and sodium (Na v ) channels. In conclusion, the multiple actions of XP-1408 rendered it as a lead compound for formulating OP insecticides with a novel mode of action.

  19. Theoretical Considerations for Improving the Pulse Power of a Battery through the Addition of a Second Electrochemically Active Material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knehr, K. W.; West, Alan C.

    Here, porous electrode theory is used to conduct case studies for when the addition of a second electrochemically active material can improve the pulse-power performance of an electrode. Case studies are conducted for the positive electrode of a sodium metal-halide battery and the graphite negative electrode of a lithium “rocking chair” battery. The replacement of a fraction of the nickel chloride capacity with iron chloride in a sodium metal-halide electrode and the replacement of a fraction of the graphite capacity with carbon black in a lithium-ion negative electrode were both predicted to increase the maximum pulse power by up tomore » 40%. In general, whether or not a second electrochemically active material increases the pulse power depends on the relative importance of ohmic-to-charge transfer resistances within the porous structure, the capacity fraction of the second electrochemically active material, and the kinetic and thermodynamic parameters of the two active materials.« less

  20. Theoretical Considerations for Improving the Pulse Power of a Battery through the Addition of a Second Electrochemically Active Material

    DOE PAGES

    Knehr, K. W.; West, Alan C.

    2016-05-26

    Here, porous electrode theory is used to conduct case studies for when the addition of a second electrochemically active material can improve the pulse-power performance of an electrode. Case studies are conducted for the positive electrode of a sodium metal-halide battery and the graphite negative electrode of a lithium “rocking chair” battery. The replacement of a fraction of the nickel chloride capacity with iron chloride in a sodium metal-halide electrode and the replacement of a fraction of the graphite capacity with carbon black in a lithium-ion negative electrode were both predicted to increase the maximum pulse power by up tomore » 40%. In general, whether or not a second electrochemically active material increases the pulse power depends on the relative importance of ohmic-to-charge transfer resistances within the porous structure, the capacity fraction of the second electrochemically active material, and the kinetic and thermodynamic parameters of the two active materials.« less

  1. Renal carcinomas associated with Xp11.2 translocations/TFE3 gene fusions: findings on MRI and computed tomography imaging.

    PubMed

    Liu, Kefu; Xie, Ping; Peng, Weijun; Zhou, Zhengrong

    2014-08-01

    To retrospectively analyze MRI and computed tomographic (CT) findings from renal carcinomas associated with Xp11.2 translocations/TFE3 gene fusions (Xp11-RCC). Institutional review board permission was obtained to review patient medical records, and the requirement for informed consent was waved . The clinical and MRI/CT features of five cases with Xp11-RCC that were confirmed by pathology were analyzed retrospectively. The image characteristics included the lesion location and size, contribution of cystic and solid components, intratumoral necrosis or hemorrhage, invasion of perinephric tissue and renal sinus, lymphadenopathy, major venous or arterial vascular invasion, pattern of the tumor growth, intratumor calcification and lipids, homogeneity of SI on T2-weighted images, attenuation and SI of the mass with respect to the normal renal cortex on precontrast and contrasted CT/MRI images, tumor SIs, tumor attenuations and tumor-to-cortex indices, homogeneity of enhancement on the contrasted images. The mean age was 32 years (range, 15-47 years). Most patients (4/5) were women. All tumors showed a cortical location. The average tumor size was 9 cm (range, 4-18 cm). Four tumors comprised a predominantly solid lesion with focal necrosis, and one tumor comprised a solid lesion with significant necrosis. All tumors showed intertumor hemorrhage, infiltrative growth and invasion of the perirenal adipose/renal sinus. Four cases showed retroperitoneal lymphadenopathy, of which one case showed simultaneous mediastinal and supraclavicular lymphadenopathy. All tumors from four cases showed mild hyperintensity on T1-weighted MRI images, and three tumors showed hypointensity on T2-weighted MRI images relative to the renal cortex except for 1 tumor that showed significant hemorrhage and a relative hyperintensity. For 3 cases who were imaged with CT, two tumors imaged using nonenhanced CT images showed mild hyperdensity relative to the renal cortex. Calcification was noted in all

  2. Biological characteristics of pediatric renal cell carcinoma associated with Xp11.2 translocations/TFE3 gene fusions.

    PubMed

    Song, Hong Cheng; Sun, Ning; Zhang, Wei Ping; He, LeJian; Fu, Libing; Huang, ChengRu

    2014-04-01

    To investigate the clinical features of pediatric Xp11.2 translocation renal cell carcinoma (RCC). A retrospective review of 22 cases over 35 years. Xp11.2 translocation RCCs were identified in 13 boys and 9 girls with a median age of 10.5 years (range: 2.5-16 years). RCC presented with hematuria in 17, abdominal mass in 1, abdominal masses with hematuria in 2, abdominal pain with hematuria in 1, and as an incidental finding in 1 patient. Ten patients were classified stage I, 10 were stage III, and two were stage IV. Of the 10 patients with stage I RCCs, 3 patients with tumor measuring less than 7 cm had nephron-sparing surgery (NSS) and 17 patients underwent simple nephrectomy. A 15-cm tumor was incompletely removed in one patient and another patient with a 25-cm × 18-cm × 15-cm tumor had gross residual. Of the 15 patients followed up between 6 months and 35 years, 13 were still living and 2 had died after surgery. Xp11.2 translocation RCC is the predominant form of pediatric RCC, associated with advanced stage at presentation. Nephrectomy is the usual treatment for RCC but NSS is an option for patients with tumors measuring<7 cm. Patients with N+M0 maintained a favorable prognosis following surgery alone. © 2014.

  3. Single-pass, efficient type-I phase-matched frequency doubling of high-power ultrashort-pulse Yb-fiber laser using LiB_3O_5

    NASA Astrophysics Data System (ADS)

    Shukla, Mukesh Kumar; Kumar, Samir; Das, Ritwick

    2016-05-01

    We report 48 % efficient single-pass second harmonic generation of high-power ultrashort-pulse ({≈ }250 fs) Yb-fiber laser by utilizing type-I phase matching in LiB_3O_5 (LBO) crystal. The choice of LBO among other borate crystals for high-power frequency doubling is essentially motivated by large thermal conductivity, low birefringence and weak group velocity dispersion. By optimally focussing the beam in a 4-mm-long LBO crystal, we have generated about 2.3 W of average power at 532 nm using 4.8 W of available pump power at 1064 nm. The ultrashort green pulses were found out to be near-transform limited sech^2 pulses with a pulse width of Δ τ ≈ 150 fs and being delivered at 78 MHz repetition rate. Due to appreciably low spatial walk-off angle for LBO ({≈ }0.4°), we obtain M^2<1.26 for the SH beam which signifies marginal distortion in comparison with the pump beam (M^2<1.15). We also discuss the impact of third-order optical nonlinearity of the LBO crystal on the generated ultrashort SH pulses.

  4. Workshop on Solid State Switches for Pulsed Power, held January 12-14, 1983 at Tamarron, Colorado

    DTIC Science & Technology

    1983-05-31

    of its anticipated scalabil- ity. However, the projected performance of other types of dis- crete switches made their continued exploration and...linking of "asynchronous AC power grids. Some present installations arid projected increases are showr. in Table 2. A new commercial power application...Average Power 62.5 KW 160 KW Device RBDT (RSR) T60R SCR 2N3873 Arra , 6 Series 10 Parallel-20 Series Table 18. Applications of solid state pulse

  5. Hydrodynamic Qualities of a 1/10-Size Powered Dynamic Model of the XP5Y-1 Flying Boat in Smooth Water: Langley Tank Model 246, TED No. NACA DE 320

    NASA Technical Reports Server (NTRS)

    Woodward, David R.; Weinstein, Irving; Whitaker, Walter E., Jr.

    1947-01-01

    The hydrodynamic characteristics of a 1/10-size powered dynamic model of the XP5Y-1 flying boat were determined in Langley tank no. 1. Stable take-offs were possible at all practicable positions of the center of gravity and flap deflections. An increase in gross load from 123.5 to 150.0 pounds (21.5 percent) had only a slight effect on the stable range for take-off. A decrease in forward acceleration from 3.0 to 1.0 feet per second per second had only a very small effect on the stable range for take-off. In general, the landings were free from skipping except at trims below 6 deg where one skip was encountered at an aft position of the center of gravity. The model porpoised during the landing runout at all positions of the center of gravity when landed at trims above 10 deg. Spray in the propellers was light at the design gross load, and was not considered excessive,at a gross load of 136.0 pounds.

  6. An adult Xp11.2 translocation renal carcinoma showing response to treatment with sunitinib.

    PubMed

    Pwint, Thinn P; Macaulay, Valentine; Roberts, Ian S D; Sullivan, Mark; Protheroe, Andrew

    2011-01-01

    A rare variant of renal cell carcinoma (RCC) with a translocation involving Xp11.2 has become increasingly recognized as a separate entity in the 2004 World Health Organization (WHO) kidney carcinoma classification. These tumors predominantly affect children and young adults and tend to present with advanced stage disease. Although reported to be indolent in children, adult cases run a more aggressive course. Little is known about their natural history, prognosis and response to therapy. We report a case of Xp11 translocation renal cancer in a 33-year-old male patient who presented with widespread rapidly progressive metastatic disease involving extensive intra-thoracic lymph nodes, supra-clavicular, retroperitoneal lymph nodes, lung nodules, and peritoneal mass. He had failed to respond to treatment with high dose interleukin 2, but showed a significant clinical response to treatment with the multikinase inhibitor sunitinib. CT scan performed after 3 cycles (18 weeks) of therapy revealed more than 65% reduction of measurable disease by response evaluation criteria in solid tumors (RECIST) criteria, resolution of other assessable lesions, and a clinical benefit that lasted for over 13 months. But unfortunately, this was subsequently followed by a rapidly progressive course. The well-recognized clinical efficacy of multikinase inhibitors such as sunitinib and sorafenib is based on the outcomes in patients with clear cell histology. There is limited data on efficacy in non-clear cell RCC, but activity in translocation RCC has not been reported. To our knowledge, this is the first documented case of Xp11 translocation carcinoma to have demonstrated an objective durable response to sunitinib. It remains unclear how resistance to sunitinib develops, but the results to date support further evaluation of sunitinib in cases of translocation RCC. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. The effects of focusing power on TEA CO2 laser-induced gas breakdown and the consequent pulse shaping effects

    NASA Astrophysics Data System (ADS)

    Beheshtipour, Saleheh; Safari, Ebrahim; Majdabadi, Abbas; Silakhori, Kaveh

    2018-02-01

    Transversely Excited Atmospheric (TEA) CO2 laser pulses were used in order to generate an optical breakdown in a variety of mono- and polyatomic molecules using different focusing powers. The dependence of the spark kernel geometry and the transmitted pulse shapes on the focusing power as well as the pressure, molecular weight, and ionization energy of the gases was investigated in detail. Partial removal of the transmitted pulse tail in the 0.05-2.6 μs range together with shortened spikes in the 10-60 ns range has been observed by applying a 2.5 cm focal length lens for all the gases. At higher focal lengths, this effect is only incompletely observed for He gas. Spatial-temporal analyses of the laser beams and the relevant plasma plumes indicate that this behavior is due to the drop in the plasma density below the critical level, before the laser pulse tail is completed.

  8. Erbium:ytterbium fiber-laser system delivering watt-level femtosecond pulses using divided pulse amplification

    NASA Astrophysics Data System (ADS)

    Herda, Robert; Zach, Armin

    2015-03-01

    We present an Erbium:Ytterbium codoped fiber-amplifer system based on Divided-Pulses-Amplification (DPA) for ultrashort pulses. The output from a saturable-absorber mode-locked polarization-maintaining (PM) fiber oscillator is amplified in a PM normal-dispersion Erbium-doped fiber. After this stage the pulses are positively chirped and have a duration of 2.0 ps at an average power of 93 mW. A stack of 5 birefringent Yttrium-Vanadate crystals divides these pulses 32 times. We amplify these pulses using a double-clad Erbium:Ytterbium codoped fiber pumped through a multimode fiber combiner. The pulses double pass the amplifier and recombine in the crystals using non-reciprocal polarization 90° rotation by a Faraday rotating mirror. Pulses with a duration of 144 fs are obtained after separation from the input beam using a polarizing beam splitter cube. These pulses have an average power of 1.85 W at a repetition rate of 80 MHz. The generation of femtosecond pulses directly from the amplifier was enabled by a positively chirped seed pulse, normally dispersive Yttrium-Vanadate crystals, and anomalously dispersive amplifier fibers. Efficient frequency doubling to 780 nm with an average power of 725 mW and a pulse duration of 156 fs is demonstrated. In summary we show a DPA setup that enables the generation of femtosecond pulses at watt-level at 1560 nm without the need for further external dechirping and demonstrate a good pulse quality by efficient frequency doubling. Due to the use of PM fiber components and a Faraday rotator the setup is environmentally stable.

  9. Phosphorylated 4EBP1 is associated with tumor progression and poor prognosis in Xp11.2 translocation renal cell carcinoma.

    PubMed

    Qu, Yuanyuan; Zhao, Rui; Wang, Hongkai; Chang, Kun; Yang, Xiaoqun; Zhou, Xiaoyan; Dai, Bo; Zhu, Yao; Shi, Guohai; Zhang, Hailiang; Ye, Dingwei

    2016-03-30

    Two main signaling pathways, PI3K-AKT-mTOR and RAS-MAPK, are involved in transmitting the proliferative signals which play critical roles in human cancers. However, the functions of these pathways in Xp11.2 RCC remain undefined. This study aimed to explore the expression of mTOR and MAPK cascades in Xp11.2 RCC and to assess the prognostic significance of proteins evaluated. Immunohistochemistry was performed to evaluate the expression of 4EBP1, p-4EBP1, p-mTOR, p-S6K and p-MAPK in 36 adult Xp11.2 RCC patients who were confirmed by FISH assay. Cox regression models were used to evaluate the prognostic value of all covariates. Among 36 assessed patients, 14 (38.9%), 26 (72.2%), 16 (44.4%), 19 (52.8%), and 9 (25.0%) patients showed high expression of 4EBP1, p-4EBP1, p-mTOR, p-S6K, and p-MAPK, respectively. We noted that p-4EBP1 expression was significantly correlated with lymph node metastases (P = 0.027). Multivariate analysis showed that high p-4EBP1 expression was an independent adverse prognostic factor for both PFS (HR = 33.750, P = 0.017) and OS (HR = 56.111, P = 0.026). Our findings suggest that p-4EBP1 may serve as a funnel factor that converge the upstream proliferative oncogenic signals. Effective inhibition of the pathways responsible for 4E-BP1 phosphorylation might be a useful strategy to improve the outcome of Xp11.2 RCC patients.

  10. SR450 and Superhawk XP applications of Bacillus thuringiensis israelensis de Barjac against Culex quinquefasciatus Say

    USDA-ARS?s Scientific Manuscript database

    Sprayer comparisons and larval morality assays were conducted following SR450 backpack mist blower and Superhawk XP thermal fogger applications of Vectobac® WDG Bacillus thuringiensis israelensis (Bti) de Barjac against Culex quinquefasciatus Say. Bacillus thuringiensis israelensis was applied at m...

  11. Performance evaluation of the Sysmex(®) XP-300 in an oncology setting: evaluation and comparison of hematological parameters with the Sysmex(®) XN-3000.

    PubMed

    van Dievoet, M A; Louagie, H; Ghys, T

    2016-10-01

    The Sysmex XP-300(®) (XP-300) is a new, fully automated hematology analyzer, designed to generate complete blood counts (CBC) with 3-part differential. In our study, the XP-300 was evaluated as a point-of-care (POC) analyzer in an oncology setting. In which blood samples from patients with different pathologies and treatments, affecting hematopoiesis, were analyzed. Performance was evaluated according to the International Council for Standardization in Haematology (ICSH) guidelines and CLSI protocol H20-A2 . Beside precision, linearity and carry-over, a comparison study with the Sysmex(®) XN-3000 (XN-3000) and a manual reference leukocyte differential was performed. Flagging performance was also evaluated. XP-300 showed excellent precision and linearity results. For within- and between-run precision, the criteria, according to Ricos et al. , were met for all parameters tested, except for platelets in the low level. Less than or equal to 0.5% carry-over was seen for all parameters tested. Comparison studies showed an acceptable correlation with both XN-3000 and the manual reference leukocyte count. A suboptimal flagging performance was demonstrated. In the context of diagnosing cytopenia due to myelosuppressing agents or leukocytosis due to infection, the XP-300 showed good analytical performance. However, in the thrombocytopenic range, precision was suboptimal. In follow-up of hematological malignancies with the occurrence of abnormal cells, we advise verification with a more advanced analyzer or with microscopic review, although further studies with a higher prevalence of abnormal cells are needed. © 2016 John Wiley & Sons Ltd.

  12. High-speed Photometric Analysis for Minor Planets 1586 Thiele, 4246 Telemann, (10662) 32-1 T-2, and (49880) 1999 XP 135

    NASA Astrophysics Data System (ADS)

    Childers, Daniel; Church, Alyssia

    2007-12-01

    Photometric observations of 1586 Thiele, 4246 Telemann, (10662) 3201 T-2, and (49880) 1999 XP135 were performed in September and October of 2005. The periods and amplitudes found were: 1586 Thiele 3.086 ± 0.038 h, 0.136 ± 0.011 mag; 4246 Telemann 8.960 ± 0.038 h, 0.109 ± 0.027 mag; (10662) 3201 T-2, 3.072 ± 0.038 h, 0.151 ± 0.04 mag; and (49880) 1999 XP135, 11.111 ± 0.038 h, 0.102 ± 0.035 mag.

  13. Uncertainties in cylindrical anode current inferences on pulsed power drivers

    NASA Astrophysics Data System (ADS)

    Porwitzky, Andrew; Brown, Justin

    2018-06-01

    For over a decade, velocimetry based techniques have been used to infer the electrical current delivered to dynamic materials properties experiments on pulsed power drivers such as the Z Machine. Though originally developed for planar load geometries, in recent years, inferring the current delivered to cylindrical coaxial loads has become a valuable diagnostic tool for numerous platforms. Presented is a summary of uncertainties that can propagate through the current inference technique when applied to expanding cylindrical anodes. An equation representing quantitative uncertainty is developed which shows the unfold method to be accurate to a few percent above 10 MA of load current.

  14. High power linear pulsed beam annealer. [Patent application

    DOEpatents

    Strathman, M.D.; Sadana, D.K.; True, R.B.

    1980-11-26

    A high power pulsed electron beam system for annealing semiconductors is comprised of an electron gun having a heated cathode, control grid and focus ring for confining the pulsed beam of electrons to a predetermined area, and a curved drift tube. The drift tube and an annular Faraday shield between the focus ring and the drift tube are maintained at a high positive voltage with respect to the cathode to accelerate electrons passing through the focus ring, thereby eliminating space charge limitations on the emission of electrons from said gun. A coil surrounding the curved drift tube provides a magnetic field which maintains the electron beam focused about the axis of the tube. The magnetic field produced by the coil around the curved tube imparts motion to electrons in a spiral path for shallow penetration of the electrons into a target. It also produces a scalloped profile of the electron beam. A second drift tube spaced a predetermined distance from the curved tube is positioned with its axis aligned with the axis of the first drift tube. The second drift tube and the target holder are maintained at a reference voltage between the cathode voltage and the curved tube voltage to decelerate the electrons. A second coil surrounding the second drift tube, maintains the electron beam focused about the axis of the second drift tube. The magnetic field of the second coil comprises the electron beam to the area of the semiconductor on the target holder.

  15. Z a Fast Pulsed Power Generator for Ultra-High Magnetic Field Generation

    NASA Astrophysics Data System (ADS)

    Spielman, R. B.; Stygar, W. A.; Struve, K. W.; Asay, J. R.; Hall, C. A.; Bernard, M. A.; Bailey, J. E.; McDaniel, D. H.

    2004-11-01

    Advances in fast, pulsed-power technologies have resulted in the development of very high current drivers that have current rise times ~100 ns. The largest such pulsed power driver today is the new Z accelerator located at Sandia National Laboratories in Albuquerque, New Mexico. Z can deliver more than 20 MA with a time-to-peak of 105 ns to low inductance (~1 nH) loads. Such large drivers are capable of directly generating magnetic fields approaching 3 kT in small, 1 cm3 volumes. In addition to direct field generation, Z can be used to compress an applied, axial seed field with a plasma. Flux compression schemes are not new and are, in fact, the basis of all explosive flux-compression generators, but we propose the use of plasma armatures rather than solid, conducting armatures. We present experimental results from the Z accelerator in which magnetic fields of ~2 kT are generated and measured with several diagnostics. Issues such as energy loss in solid conductors and dynamic response of current-carrying conductors to very large magnetic fields are reviewed in context with Z experiments. We describe planned flux-compression experiments that are expected to create the highest-magnitude uniform-field volumes yet attained in the laboratory.

  16. Characterizing rapid capacity fade and impedance evolution in high rate pulsed discharged lithium iron phosphate cells for complex, high power loads

    NASA Astrophysics Data System (ADS)

    Wong, Derek N.; Wetz, David A.; Heinzel, John M.; Mansour, Azzam N.

    2016-10-01

    Three 26650 LiFePO4 (LFP) cells are cycled using a 40 A pulsed charge/discharge profile to study their performance in high rate pulsed applications. This profile is used to simulate naval pulsed power loads planned for deployment aboard future vessels. The LFP cells studied experienced an exponential drop in their usable high-rate recharge capacity within sixty cycles due to a rapid rise in their internal resistance. Differential capacitance shows that the voltage window for charge storage is pushed outside of the recommended voltage cutoff limits. Investigation into the state of health of the electrodes shows minimal loss of active material from the cathode to side reactions. Post-mortem examination of the anodic surface films reveals a large increase in the concentration of reduced salt compounds indicating that the pulsed profile creates highly favorable conditions for LiPF6 salt to break down into LiF. This film slows the ionic movement at the interface, affecting transfer kinetics, resulting in charge buildup in the bulk anode without successful energy storage. The results indicate that the use of these cells as a power supply for high pulsed power loads is hindered because of ionically resistant film development and not by an increasing rate of active material loss.

  17. Battery-powered pulsed high density inductively coupled plasma source for pre-ionization in laboratory astrophysics experiments.

    PubMed

    Chaplin, Vernon H; Bellan, Paul M

    2015-07-01

    An electrically floating radiofrequency (RF) pre-ionization plasma source has been developed to enable neutral gas breakdown at lower pressures and to access new experimental regimes in the Caltech laboratory astrophysics experiments. The source uses a customized 13.56 MHz class D RF power amplifier that is powered by AA batteries, allowing it to safely float at 3-6 kV with the electrodes of the high voltage pulsed power experiments. The amplifier, which is capable of 3 kW output power in pulsed (<1 ms) operation, couples electrical energy to the plasma through an antenna external to the 1.1 cm radius discharge tube. By comparing the predictions of a global equilibrium discharge model with the measured scalings of plasma density with RF power input and axial magnetic field strength, we demonstrate that inductive coupling (rather than capacitive coupling or wave damping) is the dominant energy transfer mechanism. Peak ion densities exceeding 5 × 10(19) m(-3) in argon gas at 30 mTorr have been achieved with and without a background field. Installation of the pre-ionization source on a magnetohydrodynamically driven jet experiment reduced the breakdown time and jitter and allowed for the creation of hotter, faster argon plasma jets than was previously possible.

  18. Three-Level 48-Pulse STATCOM with Pulse Width Modulation

    NASA Astrophysics Data System (ADS)

    Singh, Bhim; Srinivas, Kadagala Venkata

    2016-03-01

    In this paper, a new control strategy of a three-level 48-pulse static synchronous compensator (STATCOM) is proposed with a constant dc link voltage and pulse width modulation at fundamental frequency switching. The proposed STATCOM is realized using eight units of three-level voltage source converters (VSCs) to form a three-level 48-pulse STATCOM. The conduction angle of each three-level VSC is modulated to control the ac converter output voltage, which controls the reactive power of the STATCOM. A fuzzy logic controller is used to control the STATCOM. The dynamic performance of the STATCOM is studied for the control of the reference reactive power, the reference terminal voltage and under the switching of inductive and capacitive loads.

  19. The Design and Realization of Radio Telescope Control Software in Windows XP System with VC++

    NASA Astrophysics Data System (ADS)

    Zhao, Rong-Bing; Aili, Yu; Zhang, Jin; Yu, Yun

    2007-03-01

    The main function of the radio telescope control software is to drive the radio telescope to track the target accurately. The design of radio telescope control software is based on Windows XP system with VC++. The functions of the software, communication mode and the user interface is introduced in this article.

  20. Correlation of Noise Signature to Pulsed Power Events at the HERMES III Accelerator.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Barbara; Joseph, Nathan Ryan; Salazar, Juan Diego

    2016-11-01

    The HERMES III accelerator, which is located at Sandia National Laboratories' Tech Area IV, is the largest pulsed gamma X-ray source in the world. The accelerator is made up of 20 inductive cavities that are charged to 1 MV each by complex pulsed power circuitry. The firing time of the machine components ranges between the microsecond and nanosecond timescales. This results in a variety of electromagnetic frequencies when the accelerator fires. Testing was done to identify the HERMES electromagnetic noise signal and to map it to the various accelerator trigger events. This report will show the measurement methods used tomore » capture the noise spectrum produced from the machine and correlate this noise signature with machine events.« less

  1. Torsional resistance of XP-endo Shaper at body temperature compared with several nickel-titanium rotary instruments.

    PubMed

    Elnaghy, A M; Elsaka, S E

    2018-05-01

    To compare the torsional resistance of XP-endo Shaper (XPS; size 30, .01 taper, FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments at body temperature with TRUShape (TRS; size 30, .06 taper, Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), ProFile Vortex (PV; size 30, .04 taper, Dentsply Tulsa Dental Specialties) and FlexMaster (FM; size 30, .04 taper, VDW GmbH, Munich, Germany) nickel-titanium rotary instruments. A metal block with a square-shaped mould (5 mm × 5 mm × 5 mm) was positioned inside a glass container. Five millimetres of the tip of each instrument was held inside the metal block by filling the mould with a resin composite. The instruments were tested for torsional resistance in saline solution at 37 °C. Data were analysed using one-way analysis of variance (anova) and Tukey post hoc tests. The significance level was set at P < 0.05. FM had the greatest torsional resistance amongst the instruments tested (P < 0.001). There was no significant difference between FM and PV instruments (P = 0.211). The ranking for torsional resistance values was: FM > PV > TRS > XPS. FlexMaster and ProFile Vortex instruments were more resistant to torsional stress compared with TRUShape and XP-endo Shaper instruments. The manufacturing process used to produce XP-endo Shaper instruments did not enhance their resistance to torsional stress as compared with the other instruments. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Improving the power efficiency of SOA-based UWB over fiber systems via pulse shape randomization

    NASA Astrophysics Data System (ADS)

    Taki, H.; Azou, S.; Hamie, A.; Al Housseini, A.; Alaeddine, A.; Sharaiha, A.

    2016-09-01

    A simple pulse shape randomization scheme is considered in this paper for improving the performance of ultra wide band (UWB) communication systems using On Off Keying (OOK) or pulse position modulation (PPM) formats. The advantage of the proposed scheme, which can be either employed for impulse radio (IR) or for carrier-based systems, is first theoretically studied based on closed-form derivations of power spectral densities. Then, we investigate an application to an IR-UWB over optical fiber system, by utilizing the 4th and 5th orders of Gaussian derivatives. Our approach proves to be effective for 1 Gbps-PPM and 2 Gbps-OOK transmissions, with an advantage in terms of power efficiency for short distances. We also examine the performance for a system employing an in-line Semiconductor Optical Amplifier (SOA) with the view to achieve a reach extension, while limiting the cost and system complexity.

  3. Pulse ignition characterization of mercury ion thruster hollow cathode using an improved pulse ignitor

    NASA Technical Reports Server (NTRS)

    Wintucky, E. G.; Gruber, R. P.

    1978-01-01

    An investigation of the high voltage pulse ignition characteristics of the 8 cm mercury ion thruster neutralizer cathode identified a low rate of voltage rise and long pulse duration as desirable factors for reliable cathode starting. Cathode starting breakdown voltages were measured over a range of mercury flow rates and tip heater powers for pulses with five different rates of voltage rise. Breakdown voltage requirements for the fastest rising pulse (2.5 to 3.0 kV/micro sec) were substantially higher (2 kV or more) than for the slowest rising pulse (0.3 to 0.5 kV/micro sec) for the same starting conditions. Also described is an improved, low impedance pulse ignitor circuit which reduces power losses and eliminates problems with control and packaging associated with earlier designs.

  4. Pulsed Power Discharges in Water

    NASA Astrophysics Data System (ADS)

    Kratel, Axel Wolf Hendrik

    An Electrohydraulic Discharge Process (EHD) for the treatment of hazardous chemical wastes in water has been developed. Liquid waste in a 4 L EHD reactor is directly exposed to high-energy pulsed electrical discharges between two submerged electrodes. The high-temperature (> 14,000 K) plasma channel created by an EHD discharge emits ultraviolet radiation, and produces an intense shock wave as it expands against the surrounding water. A simulation of the EHD process is presented along with experimental results. The simulation assumes a uniform plasma channel with a plasma that obeys the ideal gas law and the Spitzer conductivity law. The results agree with previously published data. The simulation is used to predict the total energy efficiency, energy partitioning, maximum plasma channel temperature and pressure for the Caltech Pulsed Power Facility (CPPF). The simulation shows that capacitance, initial voltage and gap length can be used to control the efficiency of the discharge. The oxidative degradation of 4-chlorophenol (4 -CP), 3,4-dichloroaniline (3,4-DCA), and 2,4,6 trinitrotoluene (TNT) in an EHD reactor was explored. The initial rates of degradation for the three substrates are described by a first-order rate equation, where k_{ it 0/} is the zero-order rate constant that accounts for direct photolysis; and k_ {it 1/} is the first-order term that accounts for oxidation in the plasma channel region. For 4-CP in the 4.0 L reactor, the values of these two rate constants are k_{it 0/} = 0.73 +/- 0.08 mu M, and k_{ it 1/} =(9.4 +/- 1.4) times 10^{-4}. For a 200 mu M 4-CP solution this corresponds to an overall intrinsic zero-order rate constant of 0.022 M s^{it -1/} , and a G-value of 4.45 times 10^{-3}. Ozone increases the rate and extent of degradation of the substrates in the EHD reactor. Combined EHD/ozone treatment of a 160 mu M TNT solution resulted in the complete degradation of TNT, and a 34% reduction of the total organic carbon (TOC). The intrinsic

  5. Phase II trial of capecitabine plus modified cisplatin (mXP) as first-line therapy in Japanese patients with metastatic gastric cancer (KSCC1104).

    PubMed

    Satake, Hironaga; Iwatsuki, Masaaki; Uenosono, Yoshikazu; Shiraishi, Takeshi; Tanioka, Hiroaki; Saeki, Hiroshi; Sugimachi, Keishi; Kitagawa, Dai; Shimokawa, Mototsugu; Oki, Eiji; Emi, Yasunori; Kakeji, Yoshihiro; Tsuji, Akihito; Akagi, Yoshito; Natsugoe, Shoji; Baba, Hideo; Maehara, Yoshihiko

    2017-01-01

    Capecitabine plus cisplatin (XP) is a standard therapy for metastatic gastric cancer (mGC). However, while results from previous phase III trials suggested that the cisplatin dosage should be reduced in Japanese patients, no clinical data exist to support this. Here, we conducted a multicenter study to evaluate the efficacy and safety of modified XP (mXP) in Japanese patients with mGC. Patients with previously untreated mGC received mXP (cisplatin 60 mg/m 2 on day 1 plus capecitabine 1000 mg/m 2 twice daily on days 1-14) every 3 weeks. The primary endpoint was the Response Evaluation Criteria in Solid Tumors-confirmed overall response rate (ORR). A sample size of 40 was planned for a threshold ORR of 30% and an expected value of 50%, with a one-sided α of 0.05 and a beta of approximately 0.2. Forty-two patients were enrolled. One patient did not fulfill the eligibility criteria; therefore, a total of 41 patients were assessed. The results were as follows: complete response in 2 patients, partial response in 16, stable disease in 14, progressive disease in 8, and no evaluation in 1. The confirmed ORR was 43.9% (95% confidence interval 28.7-59.1%). The median progression-free survival and median overall survival were 4.6 and 11.3 months, respectively. The most common grade 3 or 4 adverse events were neutropenia (37.5%), anemia (24.4%), anorexia (24.4%), and nausea (12.2%). First-line chemotherapy with mXP in Japanese patients with mGC did not reach its primary objective. However, it did show a promising response rate and an acceptable tolerability profile.

  6. Phosphorylated 4EBP1 is associated with tumor progression and poor prognosis in Xp11.2 translocation renal cell carcinoma

    PubMed Central

    Qu, Yuanyuan; Zhao, Rui; Wang, Hongkai; Chang, Kun; Yang, Xiaoqun; Zhou, Xiaoyan; Dai, Bo; Zhu, Yao; Shi, Guohai; Zhang, Hailiang; Ye, Dingwei

    2016-01-01

    Two main signaling pathways, PI3K-AKT-mTOR and RAS-MAPK, are involved in transmitting the proliferative signals which play critical roles in human cancers. However, the functions of these pathways in Xp11.2 RCC remain undefined. This study aimed to explore the expression of mTOR and MAPK cascades in Xp11.2 RCC and to assess the prognostic significance of proteins evaluated. Immunohistochemistry was performed to evaluate the expression of 4EBP1, p-4EBP1, p-mTOR, p-S6K and p-MAPK in 36 adult Xp11.2 RCC patients who were confirmed by FISH assay. Cox regression models were used to evaluate the prognostic value of all covariates. Among 36 assessed patients, 14 (38.9%), 26 (72.2%), 16 (44.4%), 19 (52.8%), and 9 (25.0%) patients showed high expression of 4EBP1, p-4EBP1, p-mTOR, p-S6K, and p-MAPK, respectively. We noted that p-4EBP1 expression was significantly correlated with lymph node metastases (P = 0.027). Multivariate analysis showed that high p-4EBP1 expression was an independent adverse prognostic factor for both PFS (HR = 33.750, P = 0.017) and OS (HR = 56.111, P = 0.026). Our findings suggest that p-4EBP1 may serve as a funnel factor that converge the upstream proliferative oncogenic signals. Effective inhibition of the pathways responsible for 4E-BP1 phosphorylation might be a useful strategy to improve the outcome of Xp11.2 RCC patients. PMID:27026382

  7. Low temperature growth of Ga 1- xIn xP bulk crystals from InSb-rich melt

    NASA Astrophysics Data System (ADS)

    Gennett, A.; Lewis, D.; Dutta, P. S.

    2010-04-01

    Bulk growth of phosphorus and arsenic based ternary III-V semiconductor crystals using pseudo-binary melts such as GaP-InP, GaP-GaAs, AlAs-GaAs, etc. is significantly challenging due to the high vapor pressures of group V species in conjunction with slow growth rates and the need for melt replenishment and mixing during growth. Lowering the growth temperature is desirable such that the vapor pressures of P and As can be easily handled. Low growth temperatures could be achieved by using Ga or In rich solutions. However, this approach is less attractive for growing bulk crystals due to several experimental difficulties including sticking of the growth solution to the crucible wall and to the grown crystal, making it challenging for crystal extraction. Growth of ternary crystals from low temperature quaternary melts has been found to be attractive. In this paper, we will present a new method for the growth of Ga 1- xIn xP from InSb rich Ga 1- xIn xP ySb 1- y melts at low growth temperatures in the range of 800-1050 °C. Thermodynamic phase diagrams calculated at various temperatures using a Gibbs free energy minimization software and materials databases commercially available from Thermo-Calc software will be presented along with experimental validation for Ga 1- xIn xP crystals grown at 1000 °C.

  8. A 13-year-old female with Xp11.2 translocation renal cell carcinoma; the first case diagnosed at Siriraj Hospital.

    PubMed

    Hanamornroongruang, Suchanan; Treetipsatit, Jitsupa; Pongtanakul, Bunchoo; Seangchai, Napakorn

    2012-07-01

    Xp11.2 translocation renal cell carcinomas are rare tumors characterized by translocations involving chromosome Xp11.2. These tumors are predominantly reported in pediatric patients. The authors report Xp11.2 translocation renal cell carcinoma in a 13-year-old girl who presented with asymptomatic palpable right renal mass. Right radical nephrectomy was performed and revealed a well-defined solid mass at the lower pole of the kidney. Microscopically, the tumor was composed of sheets and nests of clear to pale eosinophilic cells with some alveolar growth pattern. Psammoma bodies were detected. Immunohistochemically, the tumor cells marked with TFE3, focally marked with smooth muscle actin, HMB-45, CD68, progesterone receptor (PR) and CD10 but did not mark with epithelial markers (AE1/AE3, EMA and CAM5.2), vimentin, S-100 and p53. The presence of psammoma bodies is an important diagnostic clue for these tumors. Cytogenetic study and/or immunohistochemistry for TFE3 protein are needed for confirming the diagnosis. Currently, surgery seems to be the most effective therapy Pediatric patients with these tumors are believed to have a favorable prognosis.

  9. Verification of Bioanalytical Method for Quantification of Exogenous Insulin (Insulin Aspart) by the Analyser Advia Centaur® XP.

    PubMed

    Mihailov, Rossen; Stoeva, Dilyana; Pencheva, Blagovesta; Pentchev, Eugeni

    2018-03-01

    In a number of cases the monitoring of patients with type I diabetes mellitus requires measurement of the exogenous insulin levels. For the purpose of a clinical investigation of the efficacy of a medical device for application of exogenous insulin aspart, a verification of the method for measurement of this synthetic analogue of the hormone was needed. The information in the available medical literature for the measurement of the different exogenous insulin analogs is insufficient. Thus, verification was required to be in compliance with the active standards in Republic of Bulgaria. A manufactured method developed for ADVIA Centaur XP Immunoassay, Siemens Healthcare, was used which we verified using standard solutions and a patient serum pool by adding the appropriate quantity exogenous insulin aspart. The method was verified in accordance with the bioanalytical method verification criteria and regulatory requirements for using a standard method: CLIA chemiluminescence immunoassay ADVIA Centaur® XP. The following parameters are determined and monitored: intra-day precision and accuracy, inter-day precision and accuracy, limit of detection and lower limit of quantification, linearity, analytical recovery. The routine application of the method for measurement of immunoreactive insulin using the analyzer ADVIA Centaur® XP is directed to the measurement of endogenous insulin. The method is applicable for measuring different types of exogenous insulin, including insulin aspart.

  10. Development and characterization of a high yield transportable pulsed neutron source with efficient and compact pulsed power system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Verma, Rishi, E-mail: rishiv9@gmail.com, E-mail: rishiv@barc.gov.in; Mishra, Ekansh; Dhang, Prosenjit

    2016-09-15

    The results of characterization experiments carried out on a newly developed dense plasma focus device based intense pulsed neutron source with efficient and compact pulsed power system are reported. Its high current sealed pseudospark switch based low inductance capacitor bank with maximum stored energy of ∼10 kJ is segregated into four modules of ∼2.5 kJ each and it cumulatively delivers peak current in the range of 400 kA–600 kA (corresponding to charging voltage range of 14 kV–18 kV) in a quarter time period of ∼2 μs. The neutron yield performance of this device has been optimized by discretely varying deuteriummore » filling gas pressure in the range of 6 mbar–11 mbar at ∼17 kV/550 kA discharge. At ∼7 kJ/8.5 mbar operation, the average neutron yield has been measured to be in the order of ∼4 × 10{sup 9} neutrons/pulse which is the highest ever reported neutron yield from a plasma focus device with the same stored energy. The average forward to radial anisotropy in neutron yield is found to be ∼2. The entire system is contained on a moveable trolley having dimensions 1.5 m × 1 m × 0.7 m and its operation and control (up to the distance of 25 m) are facilitated through optically isolated handheld remote console. The overall compactness of this system provides minimum proximity to small as well as large samples for irradiation. The major intended application objective of this high neutron yield dense plasma focus device development is to explore the feasibility of active neutron interrogation experiments by utilization of intense pulsed neutron sources.« less

  11. Development and characterization of a high yield transportable pulsed neutron source with efficient and compact pulsed power system.

    PubMed

    Verma, Rishi; Mishra, Ekansh; Dhang, Prosenjit; Sagar, Karuna; Meena, Manraj; Shyam, Anurag

    2016-09-01

    The results of characterization experiments carried out on a newly developed dense plasma focus device based intense pulsed neutron source with efficient and compact pulsed power system are reported. Its high current sealed pseudospark switch based low inductance capacitor bank with maximum stored energy of ∼10 kJ is segregated into four modules of ∼2.5 kJ each and it cumulatively delivers peak current in the range of 400 kA-600 kA (corresponding to charging voltage range of 14 kV-18 kV) in a quarter time period of ∼2 μs. The neutron yield performance of this device has been optimized by discretely varying deuterium filling gas pressure in the range of 6 mbar-11 mbar at ∼17 kV/550 kA discharge. At ∼7 kJ/8.5 mbar operation, the average neutron yield has been measured to be in the order of ∼4 × 10 9 neutrons/pulse which is the highest ever reported neutron yield from a plasma focus device with the same stored energy. The average forward to radial anisotropy in neutron yield is found to be ∼2. The entire system is contained on a moveable trolley having dimensions 1.5 m × 1 m × 0.7 m and its operation and control (up to the distance of 25 m) are facilitated through optically isolated handheld remote console. The overall compactness of this system provides minimum proximity to small as well as large samples for irradiation. The major intended application objective of this high neutron yield dense plasma focus device development is to explore the feasibility of active neutron interrogation experiments by utilization of intense pulsed neutron sources.

  12. Radially polarized passively mode-locked thin-disk laser oscillator emitting sub-picosecond pulses with an average output power exceeding the 100 W level.

    PubMed

    Beirow, Frieder; Eckerle, Michael; Dannecker, Benjamin; Dietrich, Tom; Ahmed, Marwan Abdou; Graf, Thomas

    2018-02-19

    We report on a high-power passively mode-locked radially polarized Yb:YAG thin-disk oscillator providing 125 W of average output power. To the best of our knowledge, this is the highest average power ever reported from a mode-locked radially polarized oscillator without subsequent amplification stages. Mode-locking was achieved by implementing a SESAM as the cavity end mirror and the radial polarization of the LG* 01 mode was obtained by means of a circular Grating Waveguide Output Coupler. The repetition rate was 78 MHz. A pulse duration of 0.97 ps and a spectral bandwidth of 1.4 nm (FWHM) were measured at the maximum output power. This corresponds to a pulse energy of 1.6 µJ and a pulse peak power of 1.45 MW. A high degree of radial polarization of 97.3 ± 1% and an M 2 -value of 2.16 which is close to the theoretical value for the LG* 01 doughnut mode were measured.

  13. Powerful timing generator using mono-chip timers: An application to pulsed nuclear magnetic resonance

    NASA Astrophysics Data System (ADS)

    Saint-Jalmes, Hervé; Barjhoux, Yves

    1982-01-01

    We present a 10 line-7 MHz timing generator built on a single board around two LSI timer chips interfaced to a 16-bit microcomputer. Once programmed from the host computer, this device is able to generate elaborate logic sequences on its 10 output lines without further interventions from the CPU. Powerful architecture introduces new possibilities over conventional memory-based timing simulators and word generators. Loop control on a given sequence of events, loop nesting, and various logic combinations can easily be implemented through a software interface, using a symbolic command language. Typical applications of such a device range from development, emulation, and test of integrated circuits, circuit boards, and communication systems to pulse-controlled instrumentation (radar, ultrasonic systems). A particular application to a pulsed Nuclear Magnetic Resonance (NMR) spectrometer is presented, along with customization of the device for generating four-channel radio-frequency pulses and the necessary sequence for subsequent data acquisition.

  14. Investigation of Pseudo Bi-Polar Nickel Cadmium Batteries as Filter Elements for Pulsed Power Loads.

    DTIC Science & Technology

    1984-12-01

    FOR PULSED POWER LOADS THESIS Michael B. Cimino Gregory M. Gearing Major, USAF Captain, USAF AFIT/GE/ENG/84D-1B DTIC SECETE D~rR~fl"N STATEMENT A...LOADS THESIS Presented to the Faculty of the School of Engineering of the Air Force Institute of Technology Air University In Partial Fulfillment of...with the intent to make batteries capable of out performing capacitors as power supply filters. Purpose This thesis investigated the use of nickel

  15. Mental retardation in a boy with an interstitial deletion at Xp22.3 involving STS, KAL1, and OA1: Implication for the MRX locus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muroya, Koji; Ogata, Tsutomu; Natsuo, Nobutake

    Although genotype-phenotype correlations in male patients with various types of nullisomy for Xp22.3 have assigned a locus for X-linked mental retardation (MRX) to an approximately 3-Mb region between DXS31 and STS, the precise location has not been determined. In this paper, we describe a 14 7/12 year old Japanese boy with mental retardation and an interstitial deletion at Xp22.3 involving STS, KAL1, and OA1, and compare the deletion map with that of previously reported three familial male patients with low-normal intelligence and a similar interstitial deletion at Xp22.3. The results suggest that the MRX gene is further localized to themore » roughly 1.5-Mb region between DXS1060 and DXS1139. 31 refs., 4 figs.« less

  16. An experimental investigation of using carbon foam-PCM-MWCNTs composite materials for thermal management of electronic devices under pulsed power modes

    NASA Astrophysics Data System (ADS)

    Alshaer, W. G.; Rady, M. A.; Nada, S. A.; Palomo Del Barrio, Elena; Sommier, Alain

    2017-02-01

    The present article reports on a detailed experimental investigation of using carbon foam-PCM-MWCNTs composite materials for thermal management (TM) of electronic devices subjected to pulsed power. The TM module was fabricated by infiltrating paraffin wax (RT65) as a phase change material (PCM) and multi walled carbon nanotubes (MWCNTs) as a thermal conductivity enhancer in a carbon foam as a base structure. Two carbon foam materials of low and high values of thermal conductivities, CF20 and KL1-250 (3.1 and 40 W/m K), were tested as a base structure for the TM modules. Tests were conducted at different power intensities and power cycling/loading modes. Results showed that for all power varying modes and all carbon foams, the infiltration of RT65 into carbon foam reduces the temperature of TM module and results in damping the temperature spikes height. Infiltration of MWCNTS into RT65 further improves the effectiveness of TM module. Temperature damping was more pronounced in stand-alone pulsed power cycles as compared to pulsed power spikes modes. The effectiveness of inclusion of RT65 and RT65/MWCNTs in damping the temperature spikes height is remarkable in TM modules based on KL1-250 as compared to CF-20.

  17. REX, a 5-MV pulsed-power source for driving high-brightness electron beam diodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, R.L.; Kauppila, T.J.; Ridlon, R.N.

    1991-01-01

    The Relativistic Electron-beam Experiment, or REX accelerator, is a pulsed-power source capable of driving a 100-ohm load at 5 MV, 50 kA, 45 ns (FWHM) with less than a 10-ns rise and 15-ns fall time. This paper describes the pulsed-power modifications, modelling, and extensive measurements on REX to allow it to drive high impedance (100s of ohms) diode loads with a shaped voltage pulse. A major component of REX is the 1.83-m-diam {times} 25.4-cm-thick Lucite insulator with embedded grading rings that separates the output oil transmission line from the vacuum vessel that contains the re-entrant anode and cathode assemblies. Amore » radially tailored, liquid-based resistor provides a stiff voltage source that is insensitive to small variations of the diode current and, in addition, optimizes the electric field stress across the vacuum side of the insulator. The high-current operation of REX employs both multichannel peaking and point-plane diverter switches. This mode reduces the prepulse to less than 2 kV and the postpulse to less than 5% of the energy delivered to the load. Pulse shaping for the present diode load is done through two L-C transmission line filters and a tapered, glycol-based line adjacent to the water PFL and output switch. This has allowed REX to drive a diode producing a 4-MV, 4.5-kA, 55-ns flat-top electron beam with a normalized Lapostolle emittance of 0.96 mm-rad corresponding to a beam brightness in excess of 4.4 {times} 10{sup 8} A/m{sup 2} {minus}rad{sup 2}. 6 refs., 13 figs.« less

  18. Means and method for characterizing high power, ultra short laser pulses in a real time, on line manner

    DOEpatents

    Veligdan, J.T.

    1994-03-08

    An ultra short (<10 ps), high power laser pulse is temporally characterized by a system that uses a physical measurement of a wavefront that has been altered in a known manner. The system includes a first reflection switch to remove a portion of a pulse from a beam of pulses, then includes a second reflection switch, operating in a mode that is opposite to the first reflection switch, to slice off a portion of that removed portion. The sliced portion is then directed to a measuring device for physical measurement. The two reflection switches are arranged with respect to each other and with respect to the beam of ultra short pulses such that physical measurement of the sliced portion is related to the temporal measurement of the ultra short pulse by a geometric or trigonometric relationship. The reflection switches are operated by a control pulse that is directed to impinge on each of the reflection switches at a 90[degree] angle of incidence. 8 figures.

  19. Means and method for characterizing high power, ultra short laser pulses in a real time, on line manner

    DOEpatents

    Veligdan, James T.

    1994-01-01

    An ultra short (<10 ps), high power laser pulse is temporally characterized by a system that uses a physical measurement of a wavefront that has been altered in a known manner. The system includes a first reflection switch to remove a portion of a pulse from a beam of pulses, then includes a second reflection switch, operating in a mode that is opposite to the first reflection switch, to slice off a portion of that removed portion. The sliced portion is then directed to a measuring device for physical measurement. The two reflection switches are arranged with respect to each other and with respect to the beam of ultra short pulses such that physical measurement of the sliced portion is related to the temporal measurement of the ultra short pulse by a geometric or trigonometric relationship. The reflection switches are operated by a control pulse that is directed to impinge on each of the reflection switches at a 90.degree. angle of incidence.

  20. A case study of metastatic Xp11.2 translocation renal cell carcinoma effectively treated with sunitinib.

    PubMed

    Numakura, Kazuyuki; Tsuchiya, Norihiko; Yuasa, Takeshi; Saito, Mitsuru; Obara, Takashi; Tsuruta, Hiroshi; Narita, Shintaro; Horikawa, Yohei; Satoh, Shigeru; Habuchi, Tomonori

    2011-10-01

    We report a case of Xp11.2 translocation renal cell carcinoma (RCC) whose lung metastases were effectively treated with sunitinib. A 43-year-old woman presenting with upper abdominal pain was diagnosed with a left renal tumor. Laparoscopic left radical nephrectomy was performed. Histopathological examination of the surgical specimen revealed a clear-cell carcinoma of the left kidney. Two years later, multiple lung metastases were detected and the patient was treated daily with 50 mg sunitinib. A computed tomography scan performed after 2 cycles of sunitinib treatment revealed partial regression of these metastases. The partial regression has been maintained for >3 years. In retrospective evaluation of the primary RCC, tumor cells showed strong nuclear staining for transcription factor E3 (TFE3) protein and TFE3 split-fluorescence in-situ hybridization revealed translocation involving the TFE3 gene. These findings strongly support diagnosis of Xp11.2 translocation RCC.

  1. A highly efficient and compact long pulse Nd:YAG rod laser with 540 J of pulse energy for welding application.

    PubMed

    Choubey, Ambar; Vishwakarma, S C; Misra, Pushkar; Jain, R K; Agrawal, D K; Arya, R; Upadhyaya, B N; Oak, S M

    2013-07-01

    We have developed an efficient and high average power flash lamp pumped long pulse Nd:YAG laser capable of generating 1 kW of average output power with maximum 540 J of single pulse energy and 20 kW of peak power. The laser pulse duration can be varied from 1 to 40 ms and repetition rate from 1 to 100 Hz. A compact and robust laser pump chamber and resonator was designed to achieve this high average and peak power. It was found that this laser system provides highest single pulse energy as compared to other long pulsed Nd:YAG laser systems of similar rating. A slope efficiency of 5.4% has been achieved, which is on higher side for typical lamp pumped solid-state lasers. This system will be highly useful in laser welding of materials such as aluminium and titanium. We have achieved 4 mm deep penetration welding of these metals under optimized conditions of output power, pulse energy, and pulse duration. The laser resonator was optimized to provide stable operation from single shot to 100 Hz of repetition rate. The beam quality factor was measured to be M(2) ~ 91 and pulse-to-pulse stability of ±3% for the multimode operation. The laser beam was efficiently coupled through an optical fiber of 600 μm core diameter and 0.22 numerical aperture with power transmission of 90%.

  2. Uncommon Localization of Extrarenal Xp11.2 Translocation-associated Renal Cell Carcinoma (RCC): Case Report.

    PubMed

    Al-Maghrabi, Jaudah Ahmed; Khabaz, Mohamad Nidal

    2017-09-04

    The World Health Organization has recognized Xp11.2 translocation-associated renal cell carcinoma (RCC) as a distinct neoplasm that arises within the kidney. Although many reports of extrarenal carcinoma may be found in the literature, to the best of our knowledge, Xp11 translocation-associated RCC with intact kidneys has not been documented. This report describes a multilobulated right retroperitoneal soft tissue mass (7.9×5.3×12.6 cm) of a 37-year-old man complaining of abdominal pain in the right side. The patient underwent a computed tomography-guided biopsy. Microscopic evaluation reveals a tumor with papillary and sheaths architectures with cells revealing clear to eosinophilic cytoplasm. Immunohistochemical evaluation on the biopsy reveals that the tumor is positive for PAX-8, CD10, and TFE3. It is negative for CK7, EMA, Vimentin, RCC, CK8/18, D20, CD3, PLAP, OCT4, CD30, MART-1, Inhibin, S-100, HMB-45, Desmin, SMA, and DOG-1. The diagnosis was malignant epithelioid neoplasm and the diagnosis of translocation RCC was suggested. Excision was recommended. The patient underwent right radical nephrectomy with removal of this large mass. Pathologic examination showed a large cystic and solid, nonhomogenous mass with some necrotic areas, originating from the perirenal fat between the adrenal gland and the kidney. Microscopic features showed a tumor with papillary, rhabdoid, and clear cell features. Immunohistochemical stains showed that the tumor cells positively expressed AMACR, PAX-8, CD10, RCC, and TFE3, but were negative for cytokeratins, vimentin, HMB-45, desmin, SMA, EMA, and MSA. Cytogenetic studies confirmed the diagnosis of Xp11.2 translocation-associated RCC with positive TFE3 gene rearrangement. To the best of our knowledge, this type of extrarenal tumor has never been reported.

  3. High-energy and high-peak-power nanosecond pulse generation with beam quality control in 200-µm core highly multimode Yb-doped fiberamplifiers

    NASA Astrophysics Data System (ADS)

    Cheng, Ming-Yuan; Chang, Yu-Chung; Galvanauskas, Almantas; Mamidipudi, Pri; Changkakoti, Rupak; Gatchell, Peter

    2005-02-01

    We explored high-energy and high-peak-power pulse generation in large-core multimode fiber amplifiers, achieving what is to our knowledge the highest reported energies, up to 82 mJ for 500-ns pulses, 27 mJ for 50-ns pulses, and 2.4-MW peak power for 4-ns pulses at 1064 nm, using 200-µm-diameter and 0.062-N.A. core Yb-doped double-clad fiber amplifiers. The highly multimode nature of the fiber core was mitigated by use of a coiling-induced mode-filtering effect to yield a significant improvement in output-beam quality from M^2 = 25 from an uncoiled fiber to M^2 = 6.5 from a properly coiled fiber, with the corresponding reduction in number of propagating transverse modes from >or=200 to <or=20.

  4. Hollow fiber optics with improved durability for high-peak-power pulses of Q-switched Nd:YAG lasers.

    PubMed

    Matsuura, Yuji; Tsuchiuchi, Akio; Noguchi, Hiroshi; Miyagi, Mitsunobu

    2007-03-10

    To improve the damage threshold of hollow optical waveguides for transmitting Q-switched Nd:YAG laser pulses, we optimize the metallization processes for the inner coating of fibers. For silver-coated hollow fiber as the base, second, and third Nd:YAG lasers, drying silver films at a moderate temperature and with inert gas flow is found to be effective. By using this drying process, the resistance to high-peak-power optical pulse radiation is drastically improved for fibers fabricated with and without the sensitizing process. The maximum peak power transmitted in the fiber is greater than 20 MW. To improve the energy threshold of aluminum-coated hollow fibers for the fourth and fifth harmonics of Nd:YAG lasers, a thin silver film is added between the aluminum film and the glass substrate to increase adhesion of the aluminum coating. By using this primer layer, the power threshold improves to 3 MW for the fourth harmonics of a Q-switched Nd:YAG laser light.

  5. Cladding-pumped 70-kW-peak-power 2-ns-pulse Er-doped fiber amplifier

    NASA Astrophysics Data System (ADS)

    Khudyakov, M. M.; Bubnov, M. M.; Senatorov, A. K.; Lipatov, D. S.; Guryanov, A. N.; Rybaltovsky, A. A.; Butov, O. V.; Kotov, L. V.; Likhachev, M. E.

    2018-02-01

    An all-fiber pulsed erbium laser with pulse width of 2.4 ns working in a MOPA configuration has been created. Cladding pumped double clad erbium doped large mode area fiber was used in the final stage amplifier. Peculiarity of the current work is utilization of custom-made multimode diode wavelength stabilized at 981+/-0.5 nm - wavelength of maximum absorption by Er ions. It allowed us to shorten Er-doped fiber down to 1.7 m and keep a reasonably high pump-to signal conversion efficiency of 8.4%. The record output peak power for all-fiber amplifiers of 84 kW was achieved within 1555.9+/-0.15 nm spectral range.

  6. Characterisation of flash X-ray source generated by Kali-1000 Pulse Power System

    NASA Astrophysics Data System (ADS)

    Satyanarayana, N.; Durga Prasada Rao, A.; Mittal, K. C.

    2016-02-01

    The electron beam-driven Rod Pinch Diode (RPD) is presently fielded on KALI-1000 Pulse Power System at Bhabha Atomic Research Centre, Visakhapatnam and is a leading candidate for future flash X-ray radiographic sources. The diode is capable of producing less than 2-mm radiation spot sizes and greater than 350 milli rads of dose measured at 1 m from the X-ray source. KALI-1000 Pulse Power Source is capable of delivering up to 600 kV using a Tesla Transformer with Demineralized Insulated Transmission Line (DITL), the diode typically operates between 250-330 kV . Since the radiation dose has a power-law dependence on diode voltage, this limits the dose production on KALI-1000 system. Radiation dose with angular variation is measured using thermoluminescent detectors (TLD's) and the X-ray spot size is measured using pin hole arrangement with image plate (IP) to obtain the time-integrated source profile as well as a time-resolved spot diagnostic. An X-ray pinhole camera was used to pick out where the energetic e-beam connects to the anode. Ideally the diode should function such that the radiation is emitted from the tip. The camera was mounted perpendicular to the machine's axis to view the radiation from the tip. Comparison of the spot sizes of the X-ray sources obtained by the pin hole and rolled edge arrangements was carried and results obtained by both the techniques are with in ± 10% of the average values.

  7. A Brief Investigation of the Hydrodynamic Characteristics of a 1/13.33-Scale Powered Dynamic Model of a Preliminary Design of the Martin XP6M-1 Flying Boat, TED No. NACA DE-385

    NASA Technical Reports Server (NTRS)

    Blanchard, Ulysse J.

    1953-01-01

    The hydrodynamic characteristics of a preliminary design of the Martin XP6M-1 flying boat have been determined. Longitudinal stability during take-off and landing, resistance of the complete model, and behavior during taxiing and landing in rough water are presented.

  8. Long pulse acceleration of MeV class high power density negative H{sup −} ion beam for ITER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umeda, N., E-mail: umeda.naotaka@jaea.go.jp; Kojima, A.; Kashiwagi, M.

    2015-04-08

    R and D of high power density negative ion beam acceleration has been carried out at MeV test facility in JAEA to realize ITER neutral beam accelerator. The main target is H{sup −} ion beam acceleration up to 1 MeV with 200 A/m{sup 2} for 60 s whose pulse length is the present facility limit. For long pulse acceleration at high power density, new extraction grid (EXG) has been developed with high cooling capability, which electron suppression magnet is placed under cooling channel similar to ITER. In addition, aperture size of electron suppression grid (ESG) is enlarged from 14 mmmore » to 16 mm to reduce direct interception on the ESG and emission of secondary electron which leads to high heat load on the upstream acceleration grid. By enlarging ESG aperture, beam current increased 10 % at high current beam and total acceleration grid heat load reduced from 13 % to 10 % of input power at long pulse beam. In addition, heat load by back stream positive ion into the EXG is measured for the first time and is estimated as 0.3 % of beam power, while heat load by back stream ion into the source chamber is estimated as 3.5 ~ 4.0 % of beam power. Beam acceleration up to 60 s which is the facility limit, has achieved at 683 keV, 100 A/m{sup 2} of negative ion beam, whose energy density increases two orders of magnitude since 2011.« less

  9. Diffraction-limited, 300-kW peak-power pulses from a coiled multimode fiber amplifier

    NASA Astrophysics Data System (ADS)

    di Teodoro, Fabio; Koplow, Jeffrey P.; Moore, Sean W.; Kliner, Dahv A. V.

    2002-04-01

    We report a multimode, double-clad, Yb-doped fiber amplifier that produces diffraction-limited, 0.8-ns pulses with energies of 255 μJ and peak powers in excess of 300 kW at a repetition rate of ~8 kHz. Single-transverse-mode operation was obtained by bend-loss-induced mode filtering of the gain fiber.

  10. High-power femtosecond pulses without a modelocked laser

    PubMed Central

    Fu, Walter; Wright, Logan G.; Wise, Frank W.

    2017-01-01

    We demonstrate a fiber system which amplifies and compresses pulses from a gain-switched diode. A Mamyshev regenerator shortens the pulses and improves their coherence, enabling subsequent amplification by parabolic pre-shaping. As a result, we are able to control nonlinear effects and generate nearly transform-limited, 140-fs pulses with 13-MW peak power—an order-of-magnitude improvement over previous gain-switched diode sources. Seeding with a gain-switched diode results in random fluctuations of 2% in the pulse energy, which future work using known techniques may ameliorate. Further development may allow such systems to compete directly with sources based on modelocked oscillators in some applications while enjoying unparalleled robustness and repetition rate control. PMID:29214187

  11. Magnetic properties of x(Fe2O3).(100-x)[P2O5.Li2O] and x(Fe2O3).(100-x)[P2O5.CaO] glass systems

    NASA Astrophysics Data System (ADS)

    Andronache, Constantin; Racolta, Dania; Ardelean, Gheorghe

    2017-12-01

    Magnetic properties of x(Fe2O3).(100-x)[P2O5 .Li2O] and x(Fe2O3).(100-x)[P2O5 .CaO] with 0 < x ≤ 50 mol % were investigated using magnetic susceptibility measurements. The both glass systems were prepared in the same condition. The valence states and the distribution of iron ions in the glass matrix depend on the Fe2O3 content. For the P2O5.CaO glass matrix with x≤35mol%, the data revealed iron ions as isolated or participating in dipole-dipole interaction. For x > 35 mol% an antiferromagnetic coupling is observed. For the P2O5.Li2O glass matrix, the iron ions behave magnetically similarly as in other oxide glasses, but concentration of Fe2O3 over which magnetic superexchange interactions occur is lower. The absolute magnitude of θp values increases when content of Fe2O3 are increased. If the content of the magnetic ions is increased in the glass, the exchange integral increased and as a result the magnitude of the θP increases.

  12. Spiking suppression of high power QCW pulse 1319 nm Nd:YAG laser with different intracavity doublers

    NASA Astrophysics Data System (ADS)

    Bian, Qi; Zuo, Jun-Wei; Guo, Chuan; Xu, Chang; Shen, Yu; Zong, Nan; Bo, Yong; Peng, Qin-Jun; Chen, Hong-Bin; Cui, Da-Fu; Xu, Zu-Yan

    2016-09-01

    We describe the results of our efforts in suppressing spiking of a high power, high beam quality 1319 nm Nd:YAG microsecond-pulse laser with three different intracavity frequency doublers. The 1319 nm laser is generated by a quasi-continuous-wave diode-pumped Nd:YAG ring laser system. One potassium titanyl phosphate (KTP), two KTPs and one lithium triborate (LBO) as frequency doublers are installed in the ring resonator and tested, respectively. At 800 Hz repetition rate, with a pulse width of 100 µs, performances of spiking suppression for each case are observed. The average output power are 23.6 W, 22.7 W and 23.4 W with beam quality factors of M 2  =  2.21, 1.28 and 1.25 for one KTP, two KTPs and one LBO, respectively. The corresponding brightness are 270 MW/(cm2·sr), 780 MW/(cm2·sr) and 860 MW/(cm2·sr). With better beam quality, higher brightness, and easier maintainability, the LBO is the best option of the three. A laser rate equation model including the insertion loss of the doubler is applied for theoretical analysis of the output temporal pulse shape and power, and the simulated results agree well with the experimental data.

  13. Clinicopathological characteristics of Xp11.2 translocation renal cell carcinoma in adolescents and adults: Diagnosis using immunostaining of transcription factor E3 and fluorescence in situ hybridization analysis.

    PubMed

    Hirobe, Megumi; Masumori, Naoya; Tanaka, Toshiaki; Kitamura, Hiroshi; Tonooka, Akiko; Hasegawa, Tadashi; Tsukamoto, Taiji

    2016-02-01

    To determine the rate and clinicopathological features of Xp11.2 translocation carcinoma using immunostaining of transcription factor E3 and fluorescence in situ hybridization analysis. We evaluated 638 patients with renal cell carcinoma treated at Sapporo Medical University Hospital, Sapporo, Japan, from 1990 to 2009 by reviewing all hematoxylin-eosin-stained sections and carrying out immunostaining of transcription factor E3 for all cases. Fluorescence in situ hybridization analysis was carried out for patients with positive immunostaining or with findings suspicious for Xp11.2 translocation carcinoma on hematoxylin-eosin-stained sections. In this analysis, we set a cut-off level for split signals of at least 10% of nuclei. Of the 631 patients, 20 (3.2%) were positive for immunostaining. Finally, five patients were diagnosed with Xp11.2 translocation carcinoma (0.8%). Four of these patients were female and aged less than 50 years, and three cases were diagnosed as stage IV with multiple regional lymph nodal or visceral metastases. The positive predictive value of immunostaining was 25%. Patients with Xp11 translocation renal cell carcinoma tend to be younger, more frequently female and diagnosed at a more advanced stage. Immunostaining followed by fluorescence in situ hybridization analysis is an accurate and cost-effective approach for diagnosis of Xp11 translocation renal cell carcinoma. © 2015 The Japanese Urological Association.

  14. Linear transformer driver for pulse generation with fifth harmonic

    DOEpatents

    Mazarakis, Michael G.; Kim, Alexander A.; Sinebryukhov, Vadim A.; Volkov, Sergey N.; Kondratiev, Sergey S.; Alexeenko, Vitaly M.; Bayol, Frederic; Demol, Gauthier; Stygar, William A.; Leckbee, Joshua; Oliver, Bryan V.; Kiefer, Mark L.

    2017-03-21

    A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first, second, and third power delivery module. The first power delivery module sends a first energy in the form of a first pulse to the load. The second power delivery module sends a second energy in the form of a second pulse to the load. The third power delivery module sends a third energy in the form of a third pulse to the load. The linear transformer driver is configured to form a flat-top pulse by the superposition of the first, second, and third pulses. The first, second, and third pulses have different frequencies.

  15. Radar Waveform Pulse Analysis Measurement System for High-Power GaN Amplifiers

    NASA Technical Reports Server (NTRS)

    Thrivikraman, Tushar; Perkovic-Martin, Dragana; Jenabi, Masud; Hoffman, James

    2012-01-01

    This work presents a measurement system to characterize the pulsed response of high-power GaN amplifiers for use in space-based SAR platforms that require very strict amplitude and phase stability. The measurement system is able to record and analyze data on three different time scales: fast, slow, and long, which allows for greater detail of the mechanisms that impact amplitude and phase stability. The system is fully automated through MATLAB, which offers both instrument control capability and in-situ data processing. To validate this system, a high-power GaN HEMT amplifier operated in saturation was characterized. The fast time results show that variations to the amplitude and phase are correlated to DC supply transients, while long time characteristics are correlated to temperature changes.

  16. High power linear pulsed beam annealer

    DOEpatents

    Strathman, Michael D.; Sadana, Devendra K.; True, Richard B.

    1983-01-01

    A high power pulsed electron beam is produced in a system comprised of an electron gun having a heated cathode, control grid, focus ring, and a curved drift tube. The drift tube is maintained at a high positive voltage with respect to the cathode to accelerate electrons passing through the focus ring and to thereby eliminate space charge. A coil surrounding the curved drift tube provides a magnetic field which maintains the electron beam focused about the axis of the tube and imparts motion on electrons in a spiral path for shallow penetration of the electrons into a target. The curvature of the tube is selected so there is no line of sight between the cathode and a target holder positioned within a second drift tube spaced coaxially from the curved tube. The second tube and the target holder are maintained at a reference voltage that decelerates the electrons. A second coil surrounding the second drift tube maintains the electron beam focused about the axis of the second drift tube and compresses the electron beam to the area of the target. The target holder can be adjusted to position the target where the cross section of the beam matches the area of the target.

  17. Pulse transmission receiver with higher-order time derivative pulse generator

    DOEpatents

    Dress, Jr., William B.; Smith, Stephen F.

    2003-08-12

    Systems and methods for pulse-transmission low-power communication modes are disclosed. A pulse transmission receiver includes: a front-end amplification/processing circuit; a synchronization circuit coupled to the front-end amplification/processing circuit; a clock coupled to the synchronization circuit; a trigger signal generator coupled to the clock; and at least one higher-order time derivative pulse generator coupled to the trigger signal generator. The systems and methods significantly reduce lower-frequency emissions from pulse transmission spread-spectrum communication modes, which reduces potentially harmful interference to existing radio frequency services and users and also simultaneously permit transmission of multiple data bits by utilizing specific pulse shapes.

  18. Renal Cell Carcinoma Associated with Xp11.2 Translocation/TFE3 Gene Fusion: A Rare Case Report with Review of the Literature.

    PubMed

    Ahluwalia, Puneet; Nair, Balagopal; Kumar, Ginil

    2013-01-01

    Introduction. The recently recognized renal cell carcinomas associated with Xp11.2 translocations are rare tumors predominantly reported in children. Chromosome Xp11.2 translocation results in gene fusion related to transcription factor E3 (TFE3) that plays an important role in proliferation and survival. Case Report. Herein, we present two cases of a TFE3 translocation-associated RCC in young female adults, one detected incidentally and the other one presenting with gross hematuria. Tumor is characterized by immunohistochemistry and a literature review with optimal treatment regimen is presented. Discussion. Xp11.2 translocation RCCs in adult patients are associated with advanced stages, large tumors, and extracapsular disease and usually have an aggressive clinical course. Conclusion. In TFE3 RCC, the genetic background may not only contribute to tumorigenesis, but also determine the response to chemotherapy and targeted therapy. Therefore it is necessary to diagnose this tumor entity accurately. Because of the small number of TFE3 gene fusion-related renal tumors described in the literature, the exact biologic behavior and impact of current treatment modalities remain to be uncertain.

  19. Renal Cell Carcinoma Associated with Xp11.2 Translocation/TFE3 Gene Fusion: A Rare Case Report with Review of the Literature

    PubMed Central

    Ahluwalia, Puneet; Nair, Balagopal; Kumar, Ginil

    2013-01-01

    Introduction. The recently recognized renal cell carcinomas associated with Xp11.2 translocations are rare tumors predominantly reported in children. Chromosome Xp11.2 translocation results in gene fusion related to transcription factor E3 (TFE3) that plays an important role in proliferation and survival. Case Report. Herein, we present two cases of a TFE3 translocation-associated RCC in young female adults, one detected incidentally and the other one presenting with gross hematuria. Tumor is characterized by immunohistochemistry and a literature review with optimal treatment regimen is presented. Discussion. Xp11.2 translocation RCCs in adult patients are associated with advanced stages, large tumors, and extracapsular disease and usually have an aggressive clinical course. Conclusion. In TFE3 RCC, the genetic background may not only contribute to tumorigenesis, but also determine the response to chemotherapy and targeted therapy. Therefore it is necessary to diagnose this tumor entity accurately. Because of the small number of TFE3 gene fusion-related renal tumors described in the literature, the exact biologic behavior and impact of current treatment modalities remain to be uncertain. PMID:24455396

  20. Identification of a microdeletion at Xp22.13 in a Taiwanese family presenting with Nance-Horan syndrome.

    PubMed

    Liao, Hsiao-Mei; Niu, Dau-Ming; Chen, Yan-Jang; Fang, Jye-Siung; Chen, Shih-Jen; Chen, Chia-Hsiang

    2011-01-01

    Nance-Horan syndrome (NHS) is a rare X-linked disorder characterized by congenital cataracts, dental anomalies and mental retardation. The disease has been linked to a novel gene termed NHS located at Xp22.13. The majority of pathogenic mutations of the disease include nonsense mutations and small deletions and insertions that lead to truncation of the NHS protein. In this study, we identified a microdeletion of ∼ 0.92 Mb at Xp22.13 detected by array-based comparative genomic hybridization in two brothers presenting congenital cataract, dental anomalies, facial dysmorphisms and mental retardation. The deleted region encompasses the REPS2, NHS, SCML1 and RAI2 genes, and was transmitted from their carrier mother who presented only mild cataract. Our findings are in line with several recent case reports to indicate that genomic rearrangement involving the NHS gene is an important genetic etiology underlying NHS.

  1. Repetitively Pulsed Backward-Wave Oscillator Investigations

    DTIC Science & Technology

    1994-03-31

    Sinus-6 High Power BWO Experiments and Theory .................. 6 A . B W O physics .............................................................. 6...B. Experiments with high power output of BWO .............................. 8 Section III. Long Pulse Vacuum BWO Experiments...UNM) has completed its initial phase of research on repetitively pulsed high power backward-wave oscillators (BWOs). The aggressive program that we had

  2. TFE3 break-apart FISH has a higher sensitivity for Xp11.2 translocation-associated renal cell carcinoma compared with TFE3 or cathepsin K immunohistochemical staining alone: expanding the morphologic spectrum.

    PubMed

    Rao, Qiu; Williamson, Sean R; Zhang, Shaobo; Eble, John N; Grignon, David J; Wang, Mingsheng; Zhou, Xiao-Jun; Huang, Wenbin; Tan, Puay-Hoon; Maclennan, Gregory T; Cheng, Liang

    2013-06-01

    Renal cell carcinoma (RCC) associated with Xp11.2 translocation is uncommon, characterized by several different translocations involving the TFE3 gene. We assessed the utility of break-apart fluorescence in situ hybridization (FISH) in establishing the diagnosis for suspected or unclassified cases with negative or equivocal TFE3 immunostaining by analyzing 24 renal cancers with break-apart TFE3 FISH and comparing the molecular findings with the results of TFE3 and cathepsin K immunostaining in the same tumors. Ten tumors were originally diagnosed as Xp11.2 RCC on the basis of positive TFE3 immunostaining, and 14 were originally considered unclassified RCCs with negative or equivocal TFE3 staining, but with a range of features suspicious for Xp11.2 RCC. Seventeen cases showed TFE3 rearrangement associated with Xp11.2 translocation by FISH, including all 13 tumors with moderate or strong TFE3 (n=10) or cathepsin K (n=7) immunoreactivity. FISH-positive cases showed negative or equivocal immunoreactivity for TFE3 or cathepsin K in 7 and 10 tumors, respectively (both=3). None had positive immunohistochemistry but negative FISH. Morphologic features were typical for Xp11.2 RCC in 10/17 tumors. Unusual features included 1 melanotic Xp11.2 renal cancer, 1 tumor with mixed features of Xp11.2 RCC and clear cell RCC, and other tumors mimicking clear cell RCC, multilocular cystic RCC, or high-grade urothelial carcinoma. Morphology mimicking high-grade urothelial carcinoma has not been previously reported in these tumors. Psammoma bodies, hyalinized stroma, and intracellular pigment were preferentially identified in FISH-positive cases compared with FISH-negative cases. Our results support the clinical application of a TFE3 break-apart FISH assay for diagnosis and confirmation of Xp11.2 RCC and further expand the histopathologic spectrum of these neoplasms to include tumors with unusual features. A renal tumor with pathologic or clinical features highly suggestive of

  3. Analysis of Parent-of-Origin Effects on the X Chromosome in Asian and European Orofacial Cleft Triads Identifies Associations with DMD, FGF13, EGFL6, and Additional Loci at Xp22.2.

    PubMed

    Skare, Øivind; Lie, Rolv T; Haaland, Øystein A; Gjerdevik, Miriam; Romanowska, Julia; Gjessing, Håkon K; Jugessur, Astanand

    2018-01-01

    Background: Although both the mother's and father's alleles are present in the offspring, they may not operate at the same level. These parent-of-origin (PoO) effects have not yet been explored on the X chromosome, which motivated us to develop new methods for detecting such effects. Orofacial clefts (OFCs) exhibit sex-specific differences in prevalence and are examples of traits where a search for various types of effects on the X chromosome might be relevant. Materials and Methods: We upgraded our R-package Haplin to enable genome-wide analyses of PoO effects, as well as power simulations for different statistical models. 14,486 X-chromosome SNPs in 1,291 Asian and 1,118 European case-parent triads of isolated OFCs were available from a previous GWAS. For each ethnicity, cleft lip with or without cleft palate (CL/P) and cleft palate only (CPO) were analyzed separately using two X-inactivation models and a sliding-window approach to haplotype analysis. In addition, we performed analyses restricted to female offspring. Results: Associations were identified in "Dystrophin" ( DMD , Xp21.2-p21.1), "Fibroblast growth factor 13" ( FGF13 , Xq26.3-q27.1) and "EGF-like domain multiple 6" ( EGFL6 , Xp22.2), with biologically plausible links to OFCs. Unlike EGFL6 , the other associations on chromosomal region Xp22.2 had no apparent connections to OFCs. However, the Xp22.2 region itself is of potential interest because it contains genes for clefting syndromes [for example, "Oral-facial-digital syndrome 1" ( OFD1 ) and "Midline 1" ( MID1 )]. Overall, the identified associations were highly specific for ethnicity, cleft subtype and X-inactivation model, except for DMD in which associations were identified in both CPO and CL/P, in the model with X-inactivation and in Europeans only. Discussion/Conclusion: The specificity of the associations for ethnicity, cleft subtype and X-inactivation model underscores the utility of conducting subanalyses, despite the ensuing need to adjust

  4. Pulsed-DC selfsputtering of copper

    NASA Astrophysics Data System (ADS)

    Wiatrowski, A.; Posadowski, W. M.; Radzimski, Z. J.

    2008-03-01

    At standard magnetron sputtering conditions (argon pressure ~0.5 Pa) inert gas particles are often entrapped in the formed films. Inert gas contamination can be eliminated by using the self-sustained magnetron sputtering process because it is done in the absence of the inert gas atmosphere. The self-sustained sputtering (SSS) gives also a unique condition during the transport of sputtered particles to the substrate. It is especially useful for filling high aspect ratio submicron scale structures for microelectronics. So far it has been shown that the self-sputtering process can be sustained in the DC operation mode (DC-SSS) only. The main disadvantage of DC-SSS process is instability related to possible arc formation. Usage of pulsed sputtering, similarly to reactive pulsed magnetron sputtering, could eliminate this problem. In this paper results of pulsed-DC self-sustained magnetron sputtering (pulsed DC-SSS) of copper are presented for the first time. The planar magnetron equipped with a 50 mm in diameter and 6 mm thick copper target was powered by DC-power supply modulated by power switch. The maximum target power was about 11 kW (~550W/cm2). The magnetron operation was investigated as a function of pulsing frequency (20-100 kHz) and duty factor (50-90%). The discharge extinction pressure was determined for these conditions. The plasma emission spectra (400-410nm range) and deposition rates were observed for both DC and pulsed DC sustained self-sputtering processes. The presented results illustrate that stable pulsed DC-SSS process can be obtained at pulsing frequency in the range of 60-100 kHz and duty factor of 70-90%.

  5. Adaptive control system for pulsed megawatt klystrons

    DOEpatents

    Bolie, Victor W.

    1992-01-01

    The invention provides an arrangement for reducing waveform errors such as errors in phase or amplitude in output pulses produced by pulsed power output devices such as klystrons by generating an error voltage representing the extent of error still present in the trailing edge of the previous output pulse, using the error voltage to provide a stored control voltage, and applying the stored control voltage to the pulsed power output device to limit the extent of error in the leading edge of the next output pulse.

  6. Generation of powerful microwave pulses by channel power summation of two X-band phase-locked relativistic backward wave oscillators

    NASA Astrophysics Data System (ADS)

    Xiao, Renzhen; Deng, Yuqun; Chen, Changhua; Shi, Yanchao; Sun, Jun

    2018-03-01

    We demonstrate both theoretically and experimentally the possibility of the generation of powerful microwave pulses by channel power summation of two X-band phase-locked relativistic backward wave oscillators (RBWOs). A modulated electron beam induced by an external signal can lead the microwave field with an arbitrary initial phase to the same equilibrium phase, which is determined by the initial phase of the external signal. A high-current dual-beam accelerator was built to drive the two RBWOs. An external signal was divided into two channels with an adjusted relative phase and injected into the two RBWOs through two TE10-TEM mode converters. The generated microwaves were combined with a power combiner consisting of two TM01-TE11 serpentine mode converters with a common output. In the experiments, as the input power for each channel was 150 kW, the two RBWOs output 3.1 GW and 3.7 GW, respectively, the jitter of the relative phase of two output microwaves was about 20°, and the summation power from the power combiner is 6.2 GW, corresponding to a combination efficiency of 91%.

  7. Protecting the Power Grid From Electromagnetic Pulses

    NASA Astrophysics Data System (ADS)

    Simpson, Sarah

    2004-10-01

    A nuclear explosion high in the Earth's atmosphere does no immediate known harm to living things, but the resulting electromagnetic pulse (EMP) from a single detonation could degrade 70 percent or more of the country's electrical service in an instant, warns the Commission to Assess the Threat to the United States from Electromagnetic Pulse Attack, which presented its findings to the U.S. Congress in July.

  8. Ultra-low-power wireless transmitter for neural prostheses with modified pulse position modulation.

    PubMed

    Goodarzy, Farhad; Skafidas, Stan E

    2014-01-01

    An ultra-low-power wireless transmitter for embedded bionic systems is proposed, which achieves 40 pJ/b energy efficiency and delivers 500 kb/s data using the medical implant communication service frequency band (402-405 MHz). It consumes a measured peak power of 200 µW from a 1.2 V supply while occupying an active area of 0.0016 mm(2) in a 130 nm technology. A modified pulse position modulation technique called saturated amplified signal is proposed and implemented, which can reduce the overall and per bit transferred power consumption of the transmitter while reducing the complexity of the transmitter architectures, and hence potentially shrinking the size of the implemented circuitry. The design is capable of being fully integrated on single-chip solutions for surgically implanted bionic systems, wearable devices and neural embedded systems.

  9. Remote detection of radioactive material using high-power pulsed electromagnetic radiation.

    PubMed

    Kim, Dongsung; Yu, Dongho; Sawant, Ashwini; Choe, Mun Seok; Lee, Ingeun; Kim, Sung Gug; Choi, EunMi

    2017-05-09

    Remote detection of radioactive materials is impossible when the measurement location is far from the radioactive source such that the leakage of high-energy photons or electrons from the source cannot be measured. Current technologies are less effective in this respect because they only allow the detection at distances to which the high-energy photons or electrons can reach the detector. Here we demonstrate an experimental method for remote detection of radioactive materials by inducing plasma breakdown with the high-power pulsed electromagnetic waves. Measurements of the plasma formation time and its dispersion lead to enhanced detection sensitivity compared to the theoretically predicted one based only on the plasma on and off phenomena. We show that lower power of the incident electromagnetic wave is sufficient for plasma breakdown in atmospheric-pressure air and the elimination of the statistical distribution is possible in the presence of radioactive material.

  10. Remote detection of radioactive material using high-power pulsed electromagnetic radiation

    PubMed Central

    Kim, Dongsung; Yu, Dongho; Sawant, Ashwini; Choe, Mun Seok; Lee, Ingeun; Kim, Sung Gug; Choi, EunMi

    2017-01-01

    Remote detection of radioactive materials is impossible when the measurement location is far from the radioactive source such that the leakage of high-energy photons or electrons from the source cannot be measured. Current technologies are less effective in this respect because they only allow the detection at distances to which the high-energy photons or electrons can reach the detector. Here we demonstrate an experimental method for remote detection of radioactive materials by inducing plasma breakdown with the high-power pulsed electromagnetic waves. Measurements of the plasma formation time and its dispersion lead to enhanced detection sensitivity compared to the theoretically predicted one based only on the plasma on and off phenomena. We show that lower power of the incident electromagnetic wave is sufficient for plasma breakdown in atmospheric-pressure air and the elimination of the statistical distribution is possible in the presence of radioactive material. PMID:28486438

  11. Moderate high power 1 to 20μs and kHz Ho:YAG thin disk laser pulses for laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Renz, Günther

    2015-02-01

    An acousto-optically or self-oscillation pulsed thin disk Ho:YAG laser system at 2.1 μm with an average power in the 10 W range will be presented for laser lithotripsy. In the case of cw operation the thin disk Ho:YAG is either pumped with InP diode stacks or with a thulium fiber laser which leads to a laser output power of 20 W at an optical-to-optical efficiency of 30%. For the gain switched mode of operation a modulated Tm-fiber laser is used to produce self-oscillation pulses. A favored pulse lengths for uric acid stone ablation is known to be at a few μs pulse duration which can be delivered by the thin disk laser technology. In the state of the art laser lithotripter, stone material is typically ablated with 250 to 750 μs pulses at 5 to 10 Hz and with pulse energies up to a few Joule. The ablation mechanism is performed in this case by vaporization into stone dust and fragmentation. With the thin disk laser technology, 1 to 20 μs-laser pulses with a repetition rate of a few kHz and with pulse energies in the mJ-range are available. The ablation mechanism is in this case due to a local heating of the stone material with a decomposition of the crystalline structure into calcium carbonate powder which can be handled by the human body. As a joint process to this thermal effect, imploding water vapor bubbles between the fiber end and the stone material produce sporadic shock waves which help clear out the stone dust and biological material.

  12. A 13.56-mbps pulse delay modulation based transceiver for simultaneous near-field data and power transmission.

    PubMed

    Kiani, Mehdi; Ghovanloo, Maysam

    2015-02-01

    A fully-integrated near-field wireless transceiver has been presented for simultaneous data and power transmission across inductive links, which operates based on pulse delay modulation (PDM) technique. PDM is a low-power carrier-less modulation scheme that offers wide bandwidth along with robustness against strong power carrier interference, which makes it suitable for implantable neuroprosthetic devices, such as retinal implants. To transmit each bit, a pattern of narrow pulses are generated at the same frequency of the power carrier across the transmitter (Tx) data coil with specific time delays to initiate decaying ringing across the tuned receiver (Rx) data coil. This ringing shifts the zero-crossing times of the undesired power carrier interference on the Rx data coil, resulting in a phase shift between the signals across Rx power and data coils, from which the data bit stream can be recovered. A PDM transceiver prototype was fabricated in a 0.35- μm standard CMOS process, occupying 1.6 mm(2). The transceiver achieved a measured 13.56 Mbps data rate with a raw bit error rate (BER) of 4.3×10(-7) at 10 mm distance between figure-8 data coils, despite a signal-to-interference ratio (SIR) of -18.5 dB across the Rx data coil. At the same time, a class-D power amplifier, operating at 13.56 MHz, delivered 42 mW of regulated power across a separate pair of high-Q power coils, aligned with the data coils. The PDM data Tx and Rx power consumptions were 960 pJ/bit and 162 pJ/bit, respectively, at 1.8 V supply voltage.

  13. Divided-pulse nonlinear amplification and simultaneous compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hao, Qiang; Zhang, Qingshan; Sun, Tingting

    2015-03-09

    We report on a fiber laser system delivering 122 fs pulse duration and 600 mW average power at 1560 nm by the interplay between divided pulse amplification and nonlinear pulse compression. A small-core double-clad erbium-doped fiber with anomalous dispersion carries out the pulse amplification and simultaneously compresses the laser pulses such that a separate compressor is no longer necessary. A numeric simulation reveals the existence of an optimum fiber length for producing transform-limited pulses. Furthermore, frequency doubling to 780 nm with 240 mW average power and 98 fs pulse duration is achieved by using a periodically poled lithium niobate crystal at roommore » temperature.« less

  14. Conceptual design of a pulsed-power accelerator optimized for megajoule-class 1-TPa dynamic-material-physics experiments

    DOE PAGES

    Stygar, William A.; Reisman, David B.; Stoltzfus, Brian S.; ...

    2016-07-07

    In this study, we have developed a conceptual design of a next-generation pulsed-power accelerator that is optmized for driving megajoule-class dynamic-material-physics experiments at pressures as high as 1 TPa. The design is based on an accelerator architecture that is founded on three concepts: single-stage electrical-pulse compression, impedance matching, and transit-time-isolated drive circuits. Since much of the accelerator is water insulated, we refer to this machine as Neptune. The prime power source of Neptune consists of 600 independent impedance-matched Marx generators. As much as 0.8 MJ and 20 MA can be delivered in a 300-ns pulse to a 16-mΩ physics load;more » hence Neptune is a megajoule-class 20-MA arbitrary waveform generator. Neptune will allow the international scientific community to conduct dynamic equation-of-state, phase-transition, mechanical-property, and other material-physics experiments with a wide variety of well-defined drive-pressure time histories. Because Neptune can deliver on the order of a megajoule to a load, such experiments can be conducted on centimeter-scale samples at terapascal pressures with time histories as long as 1 μs.« less

  15. Cascaded Raman shifting of high-peak-power nanosecond pulses in As₂S₃ and As₂Se₃ optical fibers.

    PubMed

    White, Richard T; Monro, Tanya M

    2011-06-15

    We report efficient cascaded Raman scattering of near-IR nanosecond pulses in large-core (65 μm diameter) As₂S₃ and As₂Se₃ optical fibers. Raman scattering dominates other spectral broadening mechanisms, such as four-wave mixing, modulation instability, and soliton dynamics, because the fibers have large normal group-velocity dispersion in the spectral range of interest. With ~2 ns pump pulses at a wavelength of 1.9 μm, four Stokes peaks, all with peak powers greater than 1 kW, have been measured.

  16. Pulse generator using transistors and silicon controlled rectifiers produces high current pulses with fast rise and fall times

    NASA Technical Reports Server (NTRS)

    Woolfson, M. G.

    1966-01-01

    Electrical pulse generator uses power transistors and silicon controlled rectifiers for producing a high current pulse having fast rise and fall times. At quiescent conditions, the standby power consumption of the circuit is equal to zero.

  17. Thermal properties of borate crystals for high power optical parametric chirped-pulse amplification.

    PubMed

    Riedel, R; Rothhardt, J; Beil, K; Gronloh, B; Klenke, A; Höppner, H; Schulz, M; Teubner, U; Kränkel, C; Limpert, J; Tünnermann, A; Prandolini, M J; Tavella, F

    2014-07-28

    The potential of borate crystals, BBO, LBO and BiBO, for high average power scaling of optical parametric chirped-pulse amplifiers is investigated. Up-to-date measurements of the absorption coefficients at 515 nm and the thermal conductivities are presented. The measured absorption coefficients are a factor of 10-100 lower than reported by the literature for BBO and LBO. For BBO, a large variation of the absorption coefficients was found between crystals from different manufacturers. The linear and nonlinear absorption coefficients at 515 nm as well as thermal conductivities were determined for the first time for BiBO. Further, different crystal cooling methods are presented. In addition, the limits to power scaling of OPCPAs are discussed.

  18. Using a small hybrid pulse power transformer unit as component of a high-current opening switch for a railgun

    NASA Astrophysics Data System (ADS)

    Leung, E. M. W.; Bailey, R. E.; Michels, P. H.

    1989-03-01

    The hybrid pulse power transformer (HPPT) is a unique concept utilizing the ultrafast superconducting-to-normal transition process of a superconductor. When used in the form of a hybrid transformer current-zero switch (HTCS), this creates an approach in which the large, high-power, high-current opening switch in a conventional railgun system can be eliminated. This represents an innovative application of superconductivity to pulsed power conditioning required for the Strategic Defense Initiative (SDI). The authors explain the working principles of a 100-KJ unit capable of switching up to 500 kA at a frequency of 0.5 Hz and with a system efficiency of greater than 90 percent. Circuit analysis using a computer code called SPICE PLUS was used to verify the HTCS concept. This concept can be scaled up to applications in the several mega-ampere levels.

  19. Proof-of-Concept Experiments on a Gallium-Based Ignitron for Pulsed Power Applications

    NASA Technical Reports Server (NTRS)

    Ali, H. K.; Hanson, V. S.; Polzin, K. A.; Pearson, J. B.

    2015-01-01

    Ignitrons are electrical switching devices that operate at switching times that are on the order of microseconds, can conduct high currents of thousands of amps, and are capable of holding off tens of thousands of volts between pulses. They consist of a liquid metal pool within an evacuated tube that serves both the cathode and the source of atoms and electrons for an arc discharge. Facing the liquid metal pool is an anode suspended above the cathode, with a smaller ignitor electrode tip located just above the surface of the cathode. The ignitron can be charged to significant voltages, with a potential difference of thousands of volts between anode and cathode. When an ignition pulse is delivered from the ignitor electrode to the cathode, a small amount of the liquid metal is vaporized and subsequently ionized, with the high voltage between the anode and cathode causing the gas to bridge the gap between the two electrodes. The electrons and ions move rapidly towards the anode and cathode, respectively, with the ions liberating still more atoms from the liquid metal cathode surface as a high-current plasma arc discharge is rapidly established. This arc continues in a self-sustaining fashion until the potential difference between the anode and cathode drops below some critical value. Ignitrons have been used in a variety of pulsed power applications, including the railroad industry, industrial chemical processing, and high-power arc welding. In addition, they might prove useful in terrestrial power grid applications, serving as high-current fault switches, quickly shunting dangerous high-current or high-voltage spikes safely to ground. The motivation for this work stemmed from the fact that high-power, high-reliability, pulsed power devices like the ignitron have been used for ground testing in-space pulsed electric thruster technologies, and the continued use of ignitrons could prove advantageous to the future development and testing of such thrusters. Previous

  20. Nonthermal Biological Treatments Using Discharge Plasma Produced by Pulsed Power 4. Cleaning of Lakes and Marshes by Pulsed Power Produced Streamer Discharges in Water

    NASA Astrophysics Data System (ADS)

    Akiyama, Hidenori; Katsuki, Sunao; Namihira, Takao; Ishibashi, Kazuo; Kiyosaki, Noriaki

    Pulsed power has been used to produce non-thermal plasmas in atmospheric pressure gases that generate a high electric field at the tips of streamer discharges, where high energy electrons, free radicals, ultraviolet rays, and ozone are produced. These manifestations of streamer discharges have been used in the treatment of exhaust gases, removal of volatile and toxic compounds such as dioxin, and the sterilization of microorganisms. Here, large volume streamer discharges in water are described. These streamer discharges in liquids are able to produce a high electric field, high energy electrons, ozone, chemically active species, ultraviolet rays, and shock waves, which readily sterilize microorganisms and decompose molecules and materials. An application of this phenomenon to the cleaning of lakes and marshes is also described.

  1. Effect of different methods of pulse width modulation on power losses in an induction motor

    NASA Astrophysics Data System (ADS)

    Gulyaev, Alexander; Fokin, Dmitrii; Shuharev, Sergey; Ten, Evgenii

    2017-10-01

    We consider the calculation of modulation power losses in a system “induction motor-inverter” for various pulse width modulation (PWM) methods of the supply voltage. Presented values of modulation power losses are the result of modeling a system “DC link - two-level three-phase voltage inverter - induction motor - load”. In this study the power losses in a system “induction motor - inverter” are computed, as well as losses caused by higher harmonics of PWM supply voltage, followed by definition of active power consumed by the DC link for a specified value mechanical power on the induction motor shaft. Mechanical power was determined by the rotation speed and the torque on the motor shaft in various quasi-sinusoidal supply voltage PWM modes. These calculations reveal the best coefficient of performance (COP) in a system of a variable frequency drive (VFD) with independent voltage inverter controlled by induction motor PWM.

  2. RBM10-TFE3 Renal Cell Carcinoma: A Potential Diagnostic Pitfall Due to Cryptic Intrachromosomal Xp11.2 Inversion Resulting in False-negative TFE3 FISH.

    PubMed

    Argani, Pedram; Zhang, Lei; Reuter, Victor E; Tickoo, Satish K; Antonescu, Cristina R

    2017-05-01

    Xp11 translocation renal cell carcinoma (RCC) are defined by chromosome translocations involving the Xp11 breakpoint which results in one of a variety of TFE3 gene fusions. TFE3 break-apart florescence in situ hybridization (FISH) assays are generally preferred to TFE3 immunohistochemistry (IHC) as a means of confirming the diagnosis in archival material, as FISH is less sensitive to the variable fixation which can result in false positive or false negative IHC. Prompted by a case report in the cytogenetics literature, we identify 3 cases of Xp11 translocation RCC characterized by a subtle chromosomal inversion involving the short arm of the X chromosome, resulting in an RBM10-TFE3 gene fusion. TFE3 rearrangement was not detected by conventional TFE3 break-apart FISH, but was suggested by strong diffuse TFE3 immunoreactivity in a clean background. We then developed novel fosmid probes to detect the RBM10-TFE3 gene fusion in archival material. These cases validate RBM10-TFE3 as a recurrent gene fusion in Xp11 translocation RCC, illustrate a source of false-negative TFE3 break-apart FISH, and highlight the complementary role of TFE3 IHC and TFE3 FISH.

  3. A locus for isolated cataract on human Xp

    PubMed Central

    Francis, P; Berry, V; Hardcastle, A; Maher, E; Moore, A; Bhattacharya, S

    2002-01-01

    Purpose: To genetically map the gene causing isolated X linked cataract in a large European pedigree. Methods: Using the patient registers at Birmingham Women's Hospital, UK, we identified and examined 23 members of a four generation family with nuclear cataract. Four of six affected males also had complex congenital heart disease. Pedigree data were collated and leucocyte DNA extracted from venous blood. Linkage analysis by PCR based microsatellite marker genotyping was used to identify the disease locus and mutations within candidate genes screened by direct sequencing. Results: The disease locus was genetically refined to chromosome Xp22, within a 3 cM linkage interval flanked by markers DXS9902 and DXS999 (Zmax=3.64 at θ=0 for marker DXS8036). Conclusions: This is the first report of a locus for isolated inherited cataract on the X chromosome. The disease interval lies within the Nance-Horan locus suggesting allelic heterogeneity. The apparent association with congenital cardiac anomalies suggests a possible new oculocardiac syndrome. PMID:11836358

  4. A locus for isolated cataract on human Xp.

    PubMed

    Francis, P J; Berry, V; Hardcastle, A J; Maher, E R; Moore, A T; Bhattacharya, S S

    2002-02-01

    To genetically map the gene causing isolated X linked cataract in a large European pedigree. Using the patient registers at Birmingham Women's Hospital, UK, we identified and examined 23 members of a four generation family with nuclear cataract. Four of six affected males also had complex congenital heart disease. Pedigree data were collated and leucocyte DNA extracted from venous blood. Linkage analysis by PCR based microsatellite marker genotyping was used to identify the disease locus and mutations within candidate genes screened by direct sequencing. The disease locus was genetically refined to chromosome Xp22, within a 3 cM linkage interval flanked by markers DXS9902 and DXS999 (Zmax=3.64 at theta=0 for marker DXS8036). This is the first report of a locus for isolated inherited cataract on the X chromosome. The disease interval lies within the Nance-Horan locus suggesting allelic heterogeneity. The apparent association with congenital cardiac anomalies suggests a possible new oculocardiac syndrome.

  5. Analysis of Extreme Phenotype Bulk Copy Number Variation (XP-CNV) Identified the Association of rp1 with Resistance to Goss's Wilt of Maize.

    PubMed

    Hu, Ying; Ren, Jie; Peng, Zhao; Umana, Arnoldo A; Le, Ha; Danilova, Tatiana; Fu, Junjie; Wang, Haiyan; Robertson, Alison; Hulbert, Scot H; White, Frank F; Liu, Sanzhen

    2018-01-01

    Goss's wilt (GW) of maize is caused by the Gram-positive bacterium Clavibacter michiganensis subsp. nebraskensis (Cmn) and has spread in recent years throughout the Great Plains, posing a threat to production. The genetic basis of plant resistance is unknown. Here, a simple method for quantifying disease symptoms was developed and used to select cohorts of highly resistant and highly susceptible lines known as extreme phenotypes (XP). Copy number variation (CNV) analyses using whole genome sequences of bulked XP revealed 141 genes containing CNV between the two XP groups. The CNV genes include the previously identified common rust resistant locus rp1 . Multiple Rp1 accessions with distinct rp1 haplotypes in an otherwise susceptible accession exhibited hypersensitive responses upon inoculation. GW provides an excellent system for the genetic dissection of diseases caused by closely related subspecies of C. michiganesis . Further work will facilitate breeding strategies to control GW and provide needed insight into the resistance mechanism of important related diseases such as bacterial canker of tomato and bacterial ring rot of potato.

  6. Stabilization and control of the carrier-envelope phase of high-power femtosecond laser pulses using the direct locking technique.

    PubMed

    Imran, Tayyab; Lee, Yong S; Nam, Chang H; Hong, Kyung-Han; Yu, Tae J; Sung, Jae H

    2007-01-08

    We have stabilized and electronically controlled the carrier-envelope phase (CEP) of high-power femtosecond laser pulses, generated in a grating-based chirped-pulse amplification kHz Ti:sapphire laser, using the direct locking technique [Opt. Express 13, 2969 (2005)] combined with a slow feedback loop. An f-2f spectral interferometer has shown the CEP stabilities of 1.2 rad with the direct locking loop applied to the oscillator and of 180 mrad with an additional slow feedback loop, respectively. The electronic CEP modulations that can be easily realized in the direct locking loop are also demonstrated with the amplified pulses.

  7. Newly Designed Break-Apart and ASPL-TFE3 Dual-Fusion FISH Assay Are Useful in Diagnosing Xp11.2 Translocation Renal Cell Carcinoma and ASPL-TFE3 Renal Cell Carcinoma

    PubMed Central

    Chen, Xiancheng; Yang, Yang; Gan, Weidong; Xu, Linfeng; Ye, Qing; Guo, Hongqian

    2015-01-01

    Abstract The diagnosis of Xp11.2 translocation renal cell carcinoma (tRCC), which relies on morphology and immunohistochemistry (IHC), is often either missed in the diagnosis or misdiagnosed. To improve the accuracy of diagnosis of Xp11.2 tRCC and ASPL-TFE3 renal cell carcinoma (RCC), we investigated newly designed fluorescence in situ hybridization (FISH) probes (diagnostic accuracy study). Based on the genetic characteristics of Xp11.2 tRCC and the ASPL-TFE3 RCC, a new break-apart TFE3 FISH probe and an ASPL-TFE3 dual-fusion FISH probe were designed and applied to 65 patients with RCC who were <45 years old or showed suspicious microscopic features of Xp11.2 tRCC in our hospital. To test the accuracy of the probes, we further performed reverse transcriptase–polymerase chain reaction (PCR) on 8 cases for which frozen tissues were available. Among the 65 cases diagnosed with RCC, TFE3 IHC was positive in 24 cases. Twenty-two cases were confirmed as Xp11.2 tRCC by break-apart TFE3 FISH, and 6 of these cases were further diagnosed as ASPL-TFE3 RCC by ASPL-TFE3 dual-fusion FISH detection. Importantly, reverse transcriptase–PCR showed concordant results with the results of FISH assay in the 8 available frozen cases. The break-apart and ASPL-TFE3 dual-fusion FISH assay can accurately detect the translocation of the TFE3 gene and ASPL-TFE3 fusion gene and can thus serve as a valid complementary method for diagnosing Xp11.2 tRCC and ASPL-TFE3 RCC. PMID:25984679

  8. Refinement of the NHS locus on chromosome Xp22.13 and analysis of five candidate genes.

    PubMed

    Toutain, Annick; Dessay, Benoît; Ronce, Nathalie; Ferrante, Maria-Immacolata; Tranchemontagne, Julie; Newbury-Ecob, Ruth; Wallgren-Pettersson, Carina; Burn, John; Kaplan, Josseline; Rossi, Annick; Russo, Silvia; Walpole, Ian; Hartsfield, James K; Oyen, Nina; Nemeth, Andrea; Bitoun, Pierre; Trump, Dorothy; Moraine, Claude; Franco, Brunella

    2002-09-01

    Nance-Horan syndrome (NHS) is an X-linked condition characterised by congenital cataracts, dental abnormalities, dysmorphic features, and mental retardation in some cases. Previous studies have mapped the disease gene to a 2 cM interval on Xp22.2 between DXS43 and DXS999. We report additional linkage data resulting from the analysis of eleven independent NHS families. A maximum lod score of 9.94 (theta=0.00) was obtained at the RS1 locus and a recombination with locus DXS1195 on the telomeric side was observed in two families, thus refining the location of the gene to an interval of around 1 Mb on Xp22.13. Direct sequencing or SSCP analysis of the coding exons of five genes (SCML1, SCML2, STK9, RS1 and PPEF1), considered as candidate genes on the basis of their location in the critical interval, failed to detect any mutation in 12 unrelated NHS patients, thus making it highly unlikely that these genes are implicated in NHS.

  9. Adult-onset renal cell carcinoma associated with Xp11.2 translocations/TFE3 gene fusion with smooth muscle stroma and abnormal vessels.

    PubMed

    Kuroda, Naoto; Tamura, Masato; Tanaka, Yukichi; Hes, Ondrej; Michal, Michal; Inoue, Kaori; Ohara, Masahiko; Mizuno, Keiko; Lee, Gang-Hong

    2009-07-01

    Renal cell carcinoma (RCC) associated with Xp11.2 translocation/TFE3 gene fusion has been recently identified. Herein is presented a case of RCC with Xp11.2 translocations/TFE3 gene fusions with unusual histological findings. A 68-year-old Japanese woman was incidentally found to have a renal mass on CT. Histological examination showed clear cell neoplasm with alveolar and papillary growth patterns. The nuclear atypia corresponded to Fuhrman grade 3. Additionally, smooth muscle stroma was observed and abnormal vessels showing a heterogeniety in thickness were also identified. On immunohistochemistry, neoplastic cells were diffusely positive for transcription factor E3 (TFE3) and Melan A, and focally positive for CD10 and RCC marker. The smooth muscle stroma was positive for alpha-smooth muscle actin and h-caldesmon, but reverse transcription-polymerase chain reaction of the tumor using frozen material could not detect any previously reported chimeric transcripts including ASPL-TFE3, PRCC-TFE3, CLTC-TFE3, PSF-TFE3 or NoNo-TFE3. G-band karyotype was unsuccessful. Pathologists should pay attention to the afore-described unusual stromal reaction of adult-onset RCC associated with Xp11.2 translocations/TFE3 gene fusions.

  10. Dependence of Initial Oxygen Concentration on Ozone Yield Using Inductive Energy Storage System Pulsed Power Generator

    NASA Astrophysics Data System (ADS)

    Go, Tomio; Tanaka, Yasushi; Yamazaki, Nobuyuki; Mukaigawa, Seiji; Takaki, Koichi; Fujiwara, Tamiya

    Dependence of initial oxygen concentration on ozone yield using streamer discharge reactor driven by an inductive energy storage system pulsed power generator is described in this paper. Fast recovery type diodes were employed as semiconductor opening switch to interrupt a circuit current within 100 ns. This rapid current change produced high-voltage short pulse between a secondary energy storage inductor. The repetitive high-voltage short pulse was applied to a 1 mm diameter center wire electrode placed in a cylindrical pulse corona reactor. The streamer discharge successfully occurred between the center wire electrode and an outer cylinder ground electrode of 2 cm inner diameter. The ozone was produced with the streamer discharge and increased with increasing pulse repetition rate. The ozone yield changed in proportion to initial oxygen concentration contained in the injected gas mixture at 800 ns forward pumping time of the current. However, the decrease of the ozone yield by decreasing oxygen concentration in the gas mixture at 180 ns forward pumping time of the current was lower than the decrease at 800 ns forward pumping time of the current. This dependence of the initial oxygen concentration on ozone yield at 180 ns forward pumping time is similar to that of dielectric barrier discharge reactor.

  11. POWER RECYCLING OF BURST-MODE LASER PULSES FOR LASER PARTICLE INTERACTIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Yun

    A number of laser-particle interaction experiments such as the laser assisted hydrogen ion beam stripping or X-/ -ray generations via inverse-Compton scattering involve light sources operating in a burst mode to match the tem-poral structure of the particle beam. To mitigate the laser power challenge, it is important to make the interaction inside an optical cavity to recycle the laser power. In many cases, conventional cavity locking techniques will not work since the burst normally has a very small duty factor and low repetition rate and it is impossible to gen-erate an effective control signal. This work reports on themore » development of a doubly-resonant optical cavity scheme and its locking techniques that enables a simultaneous resonance of two laser beams with different spectra and/or temporal structures. We demonstrate that such a cavity can be used to recycle burst-mode ultra-violet laser pulses with arbitrary burst lengths and repetition rates.« less

  12. Large co-axial pulse tube preliminary results

    NASA Astrophysics Data System (ADS)

    Emery, N.; Caughley, A.; Meier, J.; Nation, M.; Tanchon, J.; Trollier, T.; Ravex, A.

    2014-01-01

    We report that Callaghan Innovation, formally known as Industrial Research Ltd (IRL), has designed and built its largest of three high frequency single-stage co-axial pulse tubes, closely coupled to a metal diaphragm pressure wave generator (PWG). The previous pulse tube achieved 110 W of cooling power @ 77 K, with an electrical input power of 3.1 kW from a 90 cc swept volume PWG. The pulse tubes have all been tuned to operate at 50 Hz, with a mean helium working pressure of 2.5 MPa. Sage pulse tube simulation software was used to model the latest pulse tube and predicted 280 W of cooling power @ 77 K. The nominal 250 W cryocooler was designed to be an intermediate step to up-scale pulse tube technology for our 1000 cc swept-volume PWG, to provide liquefaction of gases and cooling for HTS applications. Details of the modeling, design, development and preliminary experimental results are discussed.

  13. A patient with de-novo partial deletion of Xp (p11.4-pter) and partial duplication of 22q (q11.2-qter).

    PubMed

    Armour, Christine M; McGowan-Jordan, Jean; Lawrence, Sarah E; Bouchard, Amélie; Basik, Mark; Allanson, Judith E

    2008-01-01

    We report on a girl with partial deletion of Xp and partial duplication of 22q. Family studies demonstrate that both the patient's mother and her nonidentical twin sister carry the corresponding balanced translocation; 46,X,t(X;22)(p11.4;q11.2). This girl has developmental delay, microcephaly, mild dysmorphisms and hearing loss but otherwise shows few of the features described in individuals with duplications of the long arm of chromosome 22. She does manifest characteristics, such as short stature and biochemical evidence of ovarian failure, which are seen in partial or complete Xp deletions and Turner's syndrome.

  14. Diagnostic pitfall on the histological spectrum of adult-onset renal carcinoma associated with Xp11.2 translocations/TFE3 gene fusions.

    PubMed

    Kuroda, Naoto; Katto, Kazunobu; Tanaka, Yukichi; Yamaguchi, Tadanori; Inoue, Kaori; Ohara, Masahiko; Mizuno, Keiko; Hes, Ondrej; Michal, Michal; Lee, Gang-Hong

    2010-06-01

    Renal cell carcinoma (RCC) associated with Xp11.2 translocation/TFE3 gene fusion recently has been found. In this article, we demonstrate an unusual features of such a case. A 73-year-old Japanese woman presented with macroscopic hematuria. The imaging examinations disclosed the renal tumor. Histological examination showed the finding of ASPL-TFE3 RCC, which was characterized by papillary, alveolar, or solid growth of voluminous cell with clear and eosinophilic cells, and stromal psammoma body and hyaline nodules. Additionally, shrunken nuclei, thick cell border, and perinuclear clearing characteristic of chromophobe renal cell carcinoma were observed in the alveolar growth area and the transitional zone between stromal hyalinization, and osseous metaplasia was identified. Immunohistochemically, nuclei of tumorous cell were diffusely positive for TFE3. A RT-PCR study revealed the ASPL-TFE3 chimeric transcript. Finally, pathologists should recognize that the histology of RCC associated with Xp11.2 translocation/TFE3 gene fusion may focally resemble that of chromophobe RCC, but TFE3 immunohistochemistry and molecular genetic study may be helpful in the differential diagnosis. Moreover, osseous metaplasia as well as psammoma bodies should be added to the histological spectrum of the stromal change in RCC associated with Xp11.2 translocations/TFE3 gene fusions.

  15. Study on Frequency Dependency of ON-Resistance and Pulse-Loss Calculation of MOSFETs for Switch Mode Power Supply

    NASA Astrophysics Data System (ADS)

    Yamamura, Hideho; Sato, Ryohei; Iwata, Yoshiharu

    Global efforts toward energy conservation, increasing data centers, and the increasing use of IT equipments are leading to a demand in reduced power consumption of equipments, and power efficiency improvement of power supply units is becoming a necessity. MOSFETs are widely used for their low ON-resistances. Power efficiency is designed using time-domain circuit simulators, except for transformer copper-loss, which has frequency dependency which is calculated separately using methods based on skin and proximity effects. As semiconductor technology reduces the ON-resistance of MOSFETs, frequency dependency due to the skin effect or proximity effect is anticipated. In this study, ON-resistance of MOSFETs are measured and frequency dependency is confirmed. Power loss against rectangular current pulse is calculated. The calculation method for transformer copper-loss is expanded to MOSFETs. A frequency function for the resistance model is newly developed and parametric calculation is enabled. Acceleration of calculation is enabled by eliminating summation terms. Using this method, it is shown that the frequency dependent component of the measured MOSFETs increases the dissipation from 11% to 32% at a switching frequency of 100kHz. From above, this paper points out the importance of the frequency dependency of MOSFETs' ON-resistance, provides means of calculating its pulse losses, and improves loss calculation accuracy of SMPSs.

  16. Temsirolimus in the treatment of renal cell carcinoma associated with Xp11.2 translocation/TFE gene fusion proteins: a case report and review of literature.

    PubMed

    Parikh, Jigarkumar; Coleman, Teresa; Messias, Nidia; Brown, James

    2009-12-28

    Xp11.2 translocation renal cell carcinomas (TRCCs) are a rare family of tumors newly recognized by the World Health Organization (WHO) in 2004. These tumors result in the fusion of partner genes to the TFE3 gene located on Xp11.2. They are most common in the pediatric population, but have been recently implicated in adult renal cell carcinoma (RCC) presenting at an early age. TFE3-mediated direct transcriptional upregulation of the Met tyrosine kinase receptor triggers dramatic activation of downstream signaling pathways including the protein kinase B (Akt)/phosphatidylinositol-3 kinase (PI3K) and mammalian target of rapamycin (mTOR) pathways. Temsirolimus is an inhibitor of mammalian target of rapamycin (mTOR) kinase, a component of intracellular signaling pathways involved in the growth and proliferation of malignant cells. Here we present a case of a 22-year old female who has been treated with temsirolimus for her Xp11.2/TFE3 gene fusion RCC.

  17. Temsirolimus in the treatment of renal cell carcinoma associated with Xp11.2 translocation/TFE gene fusion proteins: a case report and review of literature

    PubMed Central

    Parikh, Jigarkumar; Coleman, Teresa; Messias, Nidia; Brown, James

    2009-01-01

    Xp11.2 translocation renal cell carcinomas (TRCCs) are a rare family of tumors newly recognized by the World Health Organization (WHO) in 2004. These tumors result in the fusion of partner genes to the TFE3 gene located on Xp11.2. They are most common in the pediatric population, but have been recently implicated in adult renal cell carcinoma (RCC) presenting at an early age. TFE3-mediated direct transcriptional upregulation of the Met tyrosine kinase receptor triggers dramatic activation of downstream signaling pathways including the protein kinase B (Akt)/phosphatidylinositol-3 kinase (PI3K) and mammalian target of rapamycin (mTOR) pathways. Temsirolimus is an inhibitor of mammalian target of rapamycin (mTOR) kinase, a component of intracellular signaling pathways involved in the growth and proliferation of malignant cells. Here we present a case of a 22-year old female who has been treated with temsirolimus for her Xp11.2/TFE3 gene fusion RCC. PMID:21139932

  18. Validation and utilization of a TFE3 break-apart FISH assay for Xp11.2 translocation renal cell carcinoma and alveolar soft part sarcoma.

    PubMed

    Pradhan, Dinesh; Roy, Somak; Quiroga-Garza, Gabriela; Cieply, Kathleen; Mahaffey, Alyssa L; Bastacky, Sheldon; Dhir, Rajiv; Parwani, Anil V

    2015-09-29

    Xp11.2 or TFE3 translocation renal cell carcinomas (RCC) and alveolar soft part sarcoma (ASPS) are characterized by chromosome translocations involving the Xp11.2 breakpoint resulting in transcription factor TFE3 gene fusions. The most common translocations documented in TFE3 RCCs are t(X;1) (p11.2;q21) and t(X;17) (p11.2;q25) which leads to fusion of TFE3 gene on Xp11.2 with PRCC or ASPL respectively. TFE3 immunohistochemistry (IHC) has been inconsistent over time due to background staining problems in part related to fixation issues. Karyotyping to detect TFE3 gene rearrangement requires typically unavailable fresh tissue. Reverse transcriptase-polymerase chain reaction (RT-PCR) is generally very challenging due to degradation of RNA in archival material. The study objective was to develop and validate a TFE3 break-apart fluorescence in situ hybridization (FISH) assay to confirm Xp11 translocation RCCs and ASPS. Representative sections of formalin-fixed paraffin-embedded tissue blocks were selected in 40 possible cases. Approximately 60 tumor cells were analyzed in the targeted region. The validation of TFE3 FISH was done with 11 negative and two positive cases. Cut off for a positive result was validated as >7.15 % positive nuclei with any pattern of break-apart signals. FISH evaluation was done blinded of the immunohistochemical or karyotype data. Three out of forty cases were positive for the TFE3 break-apart signals by FISH. The negative cases were reported as clear cell RCC with papillary features (10), clear cell RCC with sarcomatoid areas (2), Papillary RCC with clear cell areas (9), Chromophobe RCC (2), RCC, unclassified type (3) and renal medullary carcinoma (1). 3 of the negative cases were consultation cases for renal tumor with unknown histology. Seven negative cases were soft tissue tumor suspicious for ASPS. Our study validates the utility of TFE3 break-apart FISH on formalin-fixed paraffin-embedded tissue sections for diagnosis and confirmation of

  19. Intensity noise reduction of a high-power nonlinear femtosecond fiber amplifier based on spectral-breathing self-similar parabolic pulse evolution

    NASA Astrophysics Data System (ADS)

    Wang, Sijia; Liu, Bowen; Song, Youjian; Hu, Minglie

    2016-04-01

    We report on a simple passive scheme to reduce the intensity noise of high-power nonlinear fiber amplifiers by use of the spectral-breathing parabolic evolution of the pulse amplification with an optimized negative initial chirp. In this way, the influences of amplified spontaneous emission (ASE) on the amplifier intensity noise can be efficiently suppressed, owing to the lower overall pulse chirp, shorter spectral broadening distance, as well as the asymptotic attractive nature of self-similar pulse amplification. Systematic characterizations of the relative intensity noise (RIN) of a free-running nonlinear Yb-doped fiber amplifier are performed over a series of initial pulse parameters. Experiments show that the measured amplifier RIN increases respect to the decreased input pulse energy, due to the increased amount of ASE noise. For pulse amplification with a proper negative initial chirp, the increase of RIN is found to be smaller than with a positive initial chirp, confirming the ASE noise tolerance of the proposed spectral-breathing parabolic amplification scheme. At the maximum output average power of 27W (25-dB amplification gain), the incorporation of an optimum negative initial chirp (-0.84 chirp parameter) leads to a considerable amplifier root-mean-square (rms) RIN reduction of ~20.5% (integrated from 10 Hz to 10 MHz Fourier frequency). The minimum amplifier rms RIN of 0.025% (integrated from 1 kHz to 5 MHz Fourier frequency) is obtained along with the transform-limited compressed pulse duration of 55fs. To our knowledge, the demonstrated intensity noise performance is the lowest RIN level measured from highpower free-running femtosecond fiber amplifiers.

  20. Wind-Tunnel Development of Ailerons for the Curtiss XP-60 Airplanem Special Report

    NASA Technical Reports Server (NTRS)

    Rogallo, F. M.; Lowry, John G.

    1942-01-01

    An investigation was made in the LWAL 7- by 10-foot tunnel of internally balanced, sealed ailerons for the Curtiss XP-60 airplane. Ailerons with tabs and. with various amounts of balance were tested. Stick forces were estimated for several aileron arrangements including an arrangement recommended for the airplane. Flight tests of the recommended arrangement are discussed briefly in an appendix, The results of the wind-tunnel and flight tests indicate that the ailerons of large or fast airplanes may be satisfactorily balanced by the method developed.

  1. Optically pulsed electron accelerator

    DOEpatents

    Fraser, John S.; Sheffield, Richard L.

    1987-01-01

    An optically pulsed electron accelerator can be used as an injector for a free electron laser and comprises a pulsed light source, such as a laser, for providing discrete incident light pulses. A photoemissive electron source emits electron bursts having the same duration as the incident light pulses when impinged upon by same. The photoemissive electron source is located on an inside wall of a radio frequency powered accelerator cell which accelerates the electron burst emitted by the photoemissive electron source.

  2. Optically pulsed electron accelerator

    DOEpatents

    Fraser, J.S.; Sheffield, R.L.

    1985-05-20

    An optically pulsed electron accelerator can be used as an injector for a free electron laser and comprises a pulsed light source, such as a laser, for providing discrete incident light pulses. A photoemissive electron source emits electron bursts having the same duration as the incident light pulses when impinged upon by same. The photoemissive electron source is located on an inside wall of a radiofrequency-powered accelerator cell which accelerates the electron burst emitted by the photoemissive electron source.

  3. Generation of high-energy sub-20 fs pulses tunable in the 250-310 nm region by frequency doubling of a high-power noncollinear optical parametric amplifier.

    PubMed

    Beutler, Marcus; Ghotbi, Masood; Noack, Frank; Brida, Daniele; Manzoni, Cristian; Cerullo, Giulio

    2009-03-15

    We report on the generation of powerful sub-20 fs deep UV pulses with 10 microJ level energy and broadly tunable in the 250-310 nm range. These pulses are produced by frequency doubling a high-power noncollinear optical parametric amplifier and compressed by a pair of MgF2 prisms to an almost transform-limited duration. Our results provide a power scaling by an order of magnitude with respect to previous works.

  4. Preparation of TiN films by reactive high-power pulsed sputtering Penning discharges

    NASA Astrophysics Data System (ADS)

    Kimura, Takashi; Yoshida, Ryo; Mishima, Toshihiko; Azuma, Kingo; Nakao, Setsuo

    2018-06-01

    Titanium nitride (TiN) films are prepared by reactive high-power pulsed sputtering Penning discharges at a total pressure of 0.7 Pa and an average power of 60 W, where the nitrogen fraction is varied up to 15%. The peak value of the instantaneous power ranges between 3 and 14 kW, and the peak power density ranges between 0.3 and 1.2 kW cm‑2. The hardness of TiN films is higher than 22 GPa at the nitrogen fractions lower than 10% and it reaches 31 GPa at a nitrogen fraction of 5%. The X-ray diffraction peak of TiN(111) texture is observed for all prepared films, showing the grain size of about 10 nm. In X-ray photoelectron spectroscopy, oxygen is mainly bonded to titanium, but the intensity of the TiN bond is dominant in the entire Ti 2p spectrum. The intensity ratio of N 1s to Ti 2p ranges between 0.85 and 0.95.

  5. Interference Resilient Sigma Delta-Based Pulse Oximeter.

    PubMed

    Shokouhian, Mohsen; Morling, Richard; Kale, Izzet

    2016-06-01

    Ambient light and optical interference can severely affect the performance of pulse oximeters. The deployment of a robust modulation technique to drive the pulse oximeter LEDs can reduce these unwanted effects and increases the resilient of the pulse oximeter against artificial ambient light. The time division modulation technique used in conventional pulse oximeters can not remove the effect of modulated light coming from surrounding environment and this may cause huge measurement error in pulse oximeter readings. This paper presents a novel cross-coupled sigma delta modulator which ensures that measurement accuracy will be more robust in comparison with conventional fixed-frequency oximeter modulation technique especially in the presence of pulsed artificial ambient light. Moreover, this novel modulator gives an extra control over the pulse oximeter power consumption leading to improved power management.

  6. Green and ultraviolet pulse generation with a compact, fiber laser, chirped-pulse amplification system for aerosol fluorescence measurements.

    PubMed

    Lou, Janet W; Currie, Marc; Sivaprakasam, Vasanthi; Eversole, Jay D

    2010-10-01

    We use a compact chirped-pulse amplified system to harmonically generate ultrashort pulses for aerosol fluorescence measurements. The seed laser is a compact, all-normal dispersion, mode-locked Yb-doped fiber laser with a 1050 nm center wavelength operating at 41 MHz. Average powers of more than 1.2 W at 525 nm and 350 mW at 262 nm are generated with <500 fs pulse durations. The pulses are time-stretched with high-dispersion fiber, amplified by a high-power, large-mode-area fiber amplifier, and recompressed using a chirped volume holographic Bragg grating. The resulting high-peak-power pulses allow for highly efficient harmonic generation. We also demonstrate for the first time to our knowledge, the use of a mode-locked ultraviolet source to excite individual biological particles and other calibration particles in an inlet air flow as they pass through an optical chamber. The repetition rate is ideal for biofluorescence measurements as it allows faster sampling rates as well as the higher peak powers as compared to previously demonstrated Q-switched systems while maintaining a pulse period that is longer than the typical fluorescence lifetimes. Thus, the fluorescence excitation can be considered to be quasicontinuous and requires no external synchronization and triggering.

  7. Control of pulse format in high energy per pulse all-fiber erbium/ytterbium laser systems

    NASA Astrophysics Data System (ADS)

    Klopfer, Michael; Block, Matthew K.; Deffenbaugh, James; Fitzpatrick, Zak G.; Urioste, Michael T.; Henry, Leanne J.; Jain, Ravinder

    2017-02-01

    A multi-stage linearly polarized (PM) (15 dB) pulsed fiber laser system at 1550 nm capable of operating at repetition rates between 3 and 20 kHz was investigated. A narrow linewidth seed source was linewidth broadened to approximately 20 GHz and pulses were created and shaped via an electro-optic modulator (EOM) in conjunction with a home built arbitrary waveform generator. As expected, a high repetition rate pulse train with a near diffraction limited beam quality (M2 1.12) was achieved. However, the ability to store energy was limited by the number of active ions within the erbium/ytterbium doped gain fiber within the various stages. As a result, the maximum energy per pulse achievable from the system was approximately 0.3 and 0.38 mJ for 300 ns and 1 μs pulses, respectively, at 3 kHz. Because the system was operated at high inversion, the erbium/ytterbium doped optical fiber preferred to lase at 1535 nm versus 1550 nm resulting in amplified spontaneous emission (ASE) both intra- and inter-pulse. For the lower power stages, the ASE was controllable via a EOM whose function was to block the energy between pulses as well as ASE filters whose purpose was to block spectral components outside of the 1550 nm passband. For the higher power stages, the pump diodes were pulsed to enable strategic placement of an inversion resulting in higher intrapulse energies as well as an improved spectrum of the signal. When optimized, this system will be used to seed higher power solid state amplifier stages.

  8. Method and apparatus for stabilizing pulsed microwave amplifiers

    DOEpatents

    Hopkins, Donald B.

    1993-01-01

    Phase and amplitude variations at the output of a high power pulsed microwave amplifier arising from instabilities of the driving electron beam are suppressed with a feed-forward system that can stabilize pulses which are too brief for regulation by conventional feedback techniques. Such variations tend to be similar during successive pulses. The variations are detected during each pulse by comparing the amplifier output with the low power input signal to obtain phase and amplitude error signals. This enables storage of phase and amplitude correction signals which are used to make compensating changes in the low power input signal during the following amplifier output pulse which suppress the variations. In the preferred form of the invention, successive increments of the correction signals for each pulse are stored in separate channels of a multi-channel storage. Sequential readout of the increments during the next pulse provides variable control voltages to a voltage controlled phase shifter and voltage controlled amplitude modulator in the amplifier input signal path.

  9. Method and apparatus for stabilizing pulsed microwave amplifiers

    DOEpatents

    Hopkins, D.B.

    1993-01-26

    Phase and amplitude variations at the output of a high power pulsed microwave amplifier arising from instabilities of the driving electron beam are suppressed with a feed-forward system that can stabilize pulses which are too brief for regulation by conventional feedback techniques. Such variations tend to be similar during successive pulses. The variations are detected during each pulse by comparing the amplifier output with the low power input signal to obtain phase and amplitude error signals. This enables storage of phase and amplitude correction signals which are used to make compensating changes in the low power input signal during the following amplifier output pulse which suppress the variations. In the preferred form of the invention, successive increments of the correction signals for each pulse are stored in separate channels of a multi-channel storage. Sequential readout of the increments during the next pulse provides variable control voltages to a voltage controlled phase shifter and voltage controlled amplitude modulator in the amplifier input signal path.

  10. Development of a smartphone-based pulse oximeter with adaptive SNR/power balancing.

    PubMed

    Phelps, Tom; Haowei Jiang; Hall, Drew A

    2017-07-01

    Millions worldwide suffer from diseases that exhibit early warnings signs that can be detected by standard clinical-grade diagnostic tools. Unfortunately, such tools are often prohibitively expensive to the developing world leading to inadequate healthcare and high mortality rates. To address this problem, a smartphone-based pulse oximeter is presented that interfaces with the phone through the audio jack, enabling point-of-care measurements of heart rate (HR) and oxygen saturation (SpO 2 ). The device is designed to utilize existing phone resources (e.g., the processor, battery, and memory) resulting in a more portable and inexpensive diagnostic tool than standalone equivalents. By adaptively tuning the LED driving signal, the device is less dependent on phone-specific audio jack properties than prior audio jack-based work making it universally compatible with all smartphones. We demonstrate that the pulse oximeter can adaptively optimize the signal-to-noise ratio (SNR) within the power constraints of a mobile phone (<; 10mW) while maintaining high accuracy (HR error <; 3.4% and SpO 2 error <; 3.7%) against a clinical grade instrument.

  11. The formation of ozone and UV radiation from high-power pulsed electric discharges

    NASA Astrophysics Data System (ADS)

    Piskarev, I. M.; Ushkanov, V. A.; Selemir, V. D.; Spirov, G. M.; Malevannaya Pikar', I. A.; Zuimach, E. A.

    2008-09-01

    High-power electric discharges with pulse energies of from 0.15 J to 4 kJ were studied. The yields of UV photons and ozone were found to be approximately equal, which led us to conclude that discharge conditions under which UV radiation and ozone fully destroyed each other were possible. If ozone formation was suppressed, as when a negative volume charge was created in the spark gap region, the flux of UV photons reached 3 × 1023 photons/(cm2 s).

  12. Industrial applications of high-average power high-peak power nanosecond pulse duration Nd:YAG lasers

    NASA Astrophysics Data System (ADS)

    Harrison, Paul M.; Ellwi, Samir

    2009-02-01

    Within the vast range of laser materials processing applications, every type of successful commercial laser has been driven by a major industrial process. For high average power, high peak power, nanosecond pulse duration Nd:YAG DPSS lasers, the enabling process is high speed surface engineering. This includes applications such as thin film patterning and selective coating removal in markets such as the flat panel displays (FPD), solar and automotive industries. Applications such as these tend to require working spots that have uniform intensity distribution using specific shapes and dimensions, so a range of innovative beam delivery systems have been developed that convert the gaussian beam shape produced by the laser into a range of rectangular and/or shaped spots, as required by demands of each project. In this paper the authors will discuss the key parameters of this type of laser and examine why they are important for high speed surface engineering projects, and how they affect the underlying laser-material interaction and the removal mechanism. Several case studies will be considered in the FPD and solar markets, exploring the close link between the application, the key laser characteristics and the beam delivery system that link these together.

  13. Ultra-short pulse generator

    DOEpatents

    McEwan, Thomas E.

    1993-01-01

    An inexpensive pulse generating circuit is disclosed that generates ultra-short, 200 picosecond, and high voltage 100 kW, pulses suitable for wideband radar and other wideband applications. The circuit implements a nonlinear transmission line with series inductors and variable capacitors coupled to ground made from reverse biased diodes to sharpen and increase the amplitude of a high-voltage power MOSFET driver input pulse until it causes non-destructive transit time breakdown in a final avalanche shockwave diode, which increases and sharpens the pulse even more.

  14. RF pulse compression for future linear colliders

    NASA Astrophysics Data System (ADS)

    Wilson, Perry B.

    1995-07-01

    Future (nonsuperconducting) linear colliders will require very high values of peak rf power per meter of accelerating structure. The role of rf pulse compression in producing this power is examined within the context of overall rf system design for three future colliders at energies of 1.0-1.5 TeV, 5 TeV, and 25 TeV. In order to keep the average AC input power and the length of the accelerator within reasonable limits, a collider in the 1.0-1.5 TeV energy range will probably be built at an x-band rf frequency, and will require a peak power on the order of 150-200 MW per meter of accelerating structure. A 5 TeV collider at 34 GHz with a reasonable length (35 km) and AC input power (225 MW) would require about 550 MW per meter of structure. Two-beam accelerators can achieve peak powers of this order by applying dc pulse compression techniques (induction linac modules) to produce the drive beam. Klystron-driven colliders achieve high peak power by a combination of dc pulse compression (modulators) and rf pulse compression, with about the same overall rf system efficiency (30-40%) as a two-beam collider. A high gain (6.8) three-stage binary pulse compression system with high efficiency (80%) is described, which (compared to a SLED-II system) can be used to reduce the klystron peak power by about a factor of two, or alternatively, to cut the number of klystrons in half for a 1.0-1.5 TeV x-band collider. For a 5 TeV klystron-driven collider, a high gain, high efficiency rf pulse compression system is essential.

  15. Pulse Shaped 8-PSK Bandwidth Efficiency and Spectral Spike Elimination

    NASA Technical Reports Server (NTRS)

    Tao, Jian-Ping

    1998-01-01

    The most bandwidth-efficient communication methods are imperative to cope with the congested frequency bands. Pulse shaping methods have excellent effects on narrowing bandwidth and increasing band utilization. The position of the baseband filters for the pulse shaping is crucial. Post-modulation pulse shaping (a low pass filter is located after the modulator) can change signals from constant envelope to non-constant envelope, and non-constant envelope signals through non-linear device (a SSPA or TWT) can further spread the power spectra. Pre-modulation pulse shaping (a filter is located before the modulator) will have constant envelope. These two pulse shaping methods have different effects on narrowing the bandwidth and producing bit errors. This report studied the effect of various pre-modulation pulse shaping filters with respect to bandwidth, spectral spikes and bit error rate. A pre-modulation pulse shaped 8-ary Phase Shift Keying (8PSK) modulation was used throughout the simulations. In addition to traditional pulse shaping filters, such as Bessel, Butterworth and Square Root Raised Cosine (SRRC), other kinds of filters or pulse waveforms were also studied in the pre-modulation pulse shaping method. Simulations were conducted by using the Signal Processing Worksystem (SPW) software package on HP workstations which simulated the power spectral density of pulse shaped 8-PSK signals, end to end system performance and bit error rates (BERS) as a function of Eb/No using pulse shaping in an AWGN channel. These results are compared with the post-modulation pulse shaped 8-PSK results. The simulations indicate traditional pulse shaping filters used in pre-modulation pulse shaping may produce narrower bandwidth, but with worse BER than those in post-modulation pulse shaping. Theory and simulations show pre- modulation pulse shaping could also produce discrete line power spectra (spikes) at regular frequency intervals. These spikes may cause interference with adjacent

  16. Application of Yb:YAG short pulse laser system

    DOEpatents

    Erbert, Gaylen V.; Biswal, Subrat; Bartolick, Joseph M.; Stuart, Brent C.; Crane, John K.; Telford, Steve; Perry, Michael D.

    2004-07-06

    A diode pumped, high power (at least 20W), short pulse (up to 2 ps), chirped pulse amplified laser using Yb:YAG as the gain material is employed for material processing. Yb:YAG is used as the gain medium for both a regenerative amplifier and a high power 4-pass amplifier. A single common reflective grating optical device is used to both stretch pulses for amplification purposes and to recompress amplified pulses before being directed to a workpiece.

  17. Towards coherent combining of X-band high power microwaves: phase-locked long pulse radiations by a relativistic triaxial klystron amplifier.

    PubMed

    Ju, Jinchuan; Zhang, Jun; Qi, Zumin; Yang, Jianhua; Shu, Ting; Zhang, Jiande; Zhong, Huihuang

    2016-08-02

    The radio-frequency breakdown due to ultrahigh electric field strength essentially limits power handling capability of an individual high power microwave (HPM) generator, and this issue becomes more challenging for high frequency bands. Coherent power combining therefore provides an alternative approach to achieve an equivalent peak power of the order of ∼100 GW, which consequently provides opportunities to explore microwave related physics at extremes. The triaxial klystron amplifier (TKA) is a promising candidate for coherent power combing in high frequency bands owing to its intrinsic merit of high power capacity, nevertheless phase-locked long pulse radiation from TKA has not yet been obtained experimentally as the coaxial structure of TKA can easily lead to self-excitation of parasitic modes. In this paper, we present investigations into an X-band TKA capable of producing 1.1 GW HPMs with pulse duration of about 103 ns at the frequency of 9.375 GHz in experiment. Furthermore, the shot-to-shot fluctuation standard deviation of the phase shifts between the input and output microwaves is demonstrated to be less than 10°. The reported achievements open up prospects for accomplishing coherent power combining of X-band HPMs in the near future, and might also excite new development interests concerning high frequency TKAs.

  18. Time stretch dispersive Fourier transform based single-shot pulse-by-pulse spectrum measurement using a pulse-repetition-frequency-variable gain-switched laser

    NASA Astrophysics Data System (ADS)

    Furukawa, Hideaki; Makino, Takeshi; Wang, Xiaomin; Kobayashi, Tetsuya; Asghari, Mohammad H.; Trinh, Paul; Jalali, Bahram; Man, Wai Sing; Tsang, Kwong Shing; Wada, Naoya

    2018-02-01

    The time stretch dispersive Fourier Transform (TS-DFT) technique based on a fiber chromatic dispersion is a powerful tool for pulse-by-pulse single-shot spectrum measurement for highrepetition rate optical pulses. The distributed feedback laser diode (DFB-LD) with the gain switch operation can flexibly change the pulse repetition frequency (PRF). In this paper, we newly introduce a semiconductor gain-switched DFB-LD operating from 1 MHz up to 1 GHz PRF into the TS-DFT based spectrum measurement system to improve the flexibility and the operability. The pulse width can be below 2 ps with a pulse compression technique. We successfully measure the spectrum of each optical pulse at 1 GHz, 100 MHz, and 10 MHz PRF, and demonstrate the flexibility of the measurement system.

  19. Antibody responses of mice exposed to low-power microwaves under combined, pulse-and-amplitude modulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veyret, B.; Bouthet, C.; Deschaux, P.

    Irradiation by pulsed microwaves (9.4 GHz, 1 microsecond pulses at 1,000/s), both with and without concurrent amplitude modulation (AM) by a sinusoid at discrete frequencies between 14 and 41 MHz, was assessed for effects on the immune system of Balb/C mice. The mice were immunized either by sheep red blood cells (SRBC) or by glutaric-anhydride conjugated bovine serum albumin (GA-BSA), then exposed to the microwaves at a low rms power density (30 microW/cm2; whole-body-averaged SAR approximately 0.015 W/kg). Sham exposure or microwave irradiation took place during each of five contiguous days, 10 h/day. The antibody response was evaluated by themore » plaque-forming cell assay (SRBC experiment) or by the titration of IgM and IgG antibodies (GA-BSA experiment). In the absence of AM, the pulsed field did not greatly alter immune responsiveness. In contrast, exposure to the field under the combined-modulation condition resulted in significant, AM-frequency-dependent augmentation or weakening of immune responses.« less

  20. From few-cycle femtosecond pulse to single attosecond pulse-controlling and tracking electron dynamics with attosecond precision

    NASA Astrophysics Data System (ADS)

    Wang, He

    The few-cycle femtosecond laser pulse has proved itself to be a powerful tool for controlling the electron dynamics inside atoms and molecules. By applying such few-cycle pulses as a driving field, single isolated attosecond pulses can be produced through the high-order harmonic generation process, which provide a novel tool for capturing the real time electron motion. The first part of the thesis is devoted to the state of the art few-cycle near infrared (NIR) laser pulse development, which includes absolute phase control (carrier-envelope phase stabilization), amplitude control (power stabilization), and relative phase control (pulse compression and shaping). Then the double optical gating (DOG) method for generating single attosecond pulses and the attosecond streaking experiment for characterizing such pulses are presented. Various experimental limitations in the attosecond streaking measurement are illustrated through simulation. Finally by using the single attosecond pulses generated by DOG, an attosecond transient absorption experiment is performed to study the autoionization process of argon. When the delay between a few-cycle NIR pulse and a single attosecond XUV pulse is scanned, the Fano resonance shapes of the argon autoionizing states are modified by the NIR pulse, which shows the direct observation and control of electron-electron correlation in the temporal domain.

  1. In vitro fragmentation efficiency of holmium: yttrium-aluminum-garnet (YAG) laser lithotripsy--a comprehensive study encompassing different frequencies, pulse energies, total power levels and laser fibre diameters.

    PubMed

    Kronenberg, Peter; Traxer, Olivier

    2014-08-01

    To assess the fragmentation (ablation) efficiency of laser lithotripsy along a wide range of pulse energies, frequencies, power settings and different laser fibres, in particular to compare high- with low-frequency lithotripsy using a dynamic and innovative testing procedure free from any human interaction bias. An automated laser fragmentation testing system was developed. The unmoving laser fibres fired at the surface of an artificial stone while the stone was moved past at a constant velocity, thus creating a fissure. The lithotripter settings were 0.2-1.2 J pulse energies, 5-40 Hz frequencies, 4-20 W power levels, and 200 and 550 μm core laser fibres. Fissure width, depth, and volume were analysed and comparisons between laser settings, fibres and ablation rates were made. Low frequency-high pulse energy (LoFr-HiPE) settings were (up to six times) more ablative than high frequency-low pulse energy (HiFr-LoPE) at the same power levels (P < 0.001), as they produced deeper (P < 0.01) and wider (P < 0.001) fissures. There were linear correlations between pulse energy and fragmentation volume, fissure width, and fissure depth (all P < 0.001). Total power did not correlate with fragmentation measurements. Laser fibre diameter did not affect fragmentation volume (P = 0.81), except at very low pulse energies (0.2 J), where the large fibre was less efficient (P = 0.015). At the same total power level, LoFr-HiPE lithotripsy was most efficient. Pulse energy was the key variable that drove fragmentation efficiency. Attention must be paid to prevent the formation of time-consuming bulky debris and adapt the lithotripter settings to one's needs. As fibre diameter did not affect fragmentation efficiency, small fibres are preferable due to better scope irrigation and manoeuvrability. © 2013 The Authors. BJU International © 2013 BJU International.

  2. Development of a 33 kV, 20 A long pulse converter modulator for high average power klystron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reghu, T.; Mandloi, V.; Shrivastava, Purushottam

    Research, design, and development of high average power, long pulse modulators for the proposed Indian Spallation Neutron Source are underway at Raja Ramanna Centre for Advanced Technology. With this objective, a prototype of long pulse modulator capable of delivering 33 kV, 20 A at 5 Hz repetition rate has been designed and developed. Three Insulated Gate Bipolar Transistors (IGBT) based switching modules driving high frequency, high voltage transformers have been used to generate high voltage output. The IGBT based switching modules are shifted in phase by 120° with respect to each other. The switching frequency is 25 kHz. Pulses ofmore » 1.6 ms pulse width, 80 μs rise time, and 70 μs fall time have been achieved at the modulator output. A droop of ±0.6% is achieved using a simple segmented digital droop correction technique. The total fault energy transferred to the load during fault has been measured by conducting wire burn tests and is found to be within 3.5 J.« less

  3. Development of a 33 kV, 20 A long pulse converter modulator for high average power klystron

    NASA Astrophysics Data System (ADS)

    Reghu, T.; Mandloi, V.; Shrivastava, Purushottam

    2014-05-01

    Research, design, and development of high average power, long pulse modulators for the proposed Indian Spallation Neutron Source are underway at Raja Ramanna Centre for Advanced Technology. With this objective, a prototype of long pulse modulator capable of delivering 33 kV, 20 A at 5 Hz repetition rate has been designed and developed. Three Insulated Gate Bipolar Transistors (IGBT) based switching modules driving high frequency, high voltage transformers have been used to generate high voltage output. The IGBT based switching modules are shifted in phase by 120° with respect to each other. The switching frequency is 25 kHz. Pulses of 1.6 ms pulse width, 80 μs rise time, and 70 μs fall time have been achieved at the modulator output. A droop of ±0.6% is achieved using a simple segmented digital droop correction technique. The total fault energy transferred to the load during fault has been measured by conducting wire burn tests and is found to be within 3.5 J.

  4. A long-pulse repetitive operation magnetically insulated transmission line oscillator.

    PubMed

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-05-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  5. Ultra-short pulse generator

    DOEpatents

    McEwan, T.E.

    1993-12-28

    An inexpensive pulse generating circuit is disclosed that generates ultra-short, 200 picosecond, and high voltage 100 kW, pulses suitable for wideband radar and other wideband applications. The circuit implements a nonlinear transmission line with series inductors and variable capacitors coupled to ground made from reverse biased diodes to sharpen and increase the amplitude of a high-voltage power MOSFET driver input pulse until it causes non-destructive transit time breakdown in a final avalanche shock wave diode, which increases and sharpens the pulse even more. 5 figures.

  6. Identification and characterization of a novel serine-threonine kinase gene from the Xp22 region.

    PubMed

    Montini, E; Andolfi, G; Caruso, A; Buchner, G; Walpole, S M; Mariani, M; Consalez, G; Trump, D; Ballabio, A; Franco, B

    1998-08-01

    Eukaryotic protein kinases are part of a large and expanding family of proteins. Through our transcriptional mapping effort in the Xp22 region, we have isolated and sequenced the full-length transcript of STK9, a novel cDNA highly homologous to serine-threonine kinases. A number of human genetic disorders have been mapped to the region where STK9 has been localized including Nance-Horan (NH) syndrome, oral-facial-digital syndrome type 1 (OFD1), and a novel locus for nonsyndromic sensorineural deafness (DFN6). To evaluate the possible involvement of STK9 in any of the above-mentioned disorders, a 2416-bp full-length cDNA was assembled. The entire genomic structure of the gene, which is composed of 20 coding exons, was determined. Northern analysis revealed a transcript larger than 9.5 kb in several tissues including brain, lung, and kidney. The mouse homologue (Stk9) was identified and mapped in the mouse in the region syntenic to human Xp. This location is compatible with the location of the Xcat mutant, which shows congenital cataracts very similar to those observed in NH patients. Sequence homologies, expression pattern, and mapping information in both human and mouse make STK9 a candidate gene for the above-mentioned disorders. Copyright 1998 Academic Press.

  7. Increased first and second pulse harmonics in Tai Chi Chuan practitioners.

    PubMed

    Lu, Wan-An; Chen, Yung-Sheng; Kuo, Cheng-Deng

    2016-02-29

    Tai Chi Chuan (TCC) is known to be a good calisthenics for people. This study examined the relationship between pulse harmonics and autonomic nervous modulation in TCC practitioners. Power spectral measures of right pulse wave and heart rate variability (HRV) measures were compared between TCC practitioners and control subjects. Correlation analyses between pulse harmonics and HRV measures were performed using linear regression analysis. At baseline, the total power of pulse (TPp), powers of all individual pulse harmonics, normalized power of the 1(st) harmonics (nPh1) of TCC practitioners were greater, while the normalized power of the 4(th) pulse harmonics (nPh4) of TCC practitioners was smaller, than those of the controls. Similarly, the baseline standard deviation (SD(RR)), coefficient of variation (CV(RR)), and normalized high-frequency power (nHFP) of RR intervals were smaller, while the normalized very low-frequency power (nVLFP) and low-/high- frequency power ratio (LHR) were larger in the TCC practitioners. The TCC age correlated significantly and negatively with nPh1, and nearly significantly and negatively with nPh2 in the TCC practitioners. Thirty min after TCC exercise, the percentage changes in mRRI, SDRR, TP, VLFP were decreased, while the percentage changes in HR, ULFP, nLFP, and Ph2 were increased, relative to the controls. Correlation analysis shows that the %Ph2 correlates significantly and negatively with %mRRI and significantly and positively with %HR. The TCC practitioners had increased baseline total power of pulse and the 1(st) and 2(nd) pulse harmonics, and decreased power of the 4(th) pulse harmonics, along with decreased vagal modulation and increased sympathetic modulation. After TCC exercise, the power of the 2(nd) harmonics of TCC practitioners was increased which might be related to the increase in HR due to decreased vascular resistance after TCC exercise.

  8. Genotype-phenotype characterization in 13 individuals with chromosome Xp11.22 duplications.

    PubMed

    Grams, Sarah E; Argiropoulos, Bob; Lines, Matthew; Chakraborty, Pranesh; Mcgowan-Jordan, Jean; Geraghty, Michael T; Tsang, Marilyn; Eswara, Marthand; Tezcan, Kamer; Adams, Kelly L; Linck, Leesa; Himes, Patricia; Kostiner, Dana; Zand, Dina J; Stalker, Heather; Driscoll, Daniel J; Huang, Taosheng; Rosenfeld, Jill A; Li, Xu; Chen, Emily

    2016-04-01

    We report 13 new individuals with duplications in Xp11.22-p11.23. The index family has one male and two female members in three generations with mild-severe intellectual disability (ID), speech delay, dysmorphic features, early puberty, constipation, and/or hand and foot abnormalities. Affected individuals were found to have two small duplications in Xp11.22 at nucleotide position (hg19) 50,112,063-50,456,458 bp (distal) and 53,160,114-53,713,154 bp (proximal). Collectively, these two regions include 14 RefSeq genes, prompting collection of a larger cohort of patients, in an attempt to delineate critical genes associated with the observed phenotype. In total, we have collected data on nine individuals with duplications overlapping the distal duplication region containing SHROOM4 and DGKK and eight individuals overlapping the proximal region including HUWE1. Duplications of HUWE1 have been previously associated with non-syndromic ID. Our data, with previously published reports, suggest that duplications involving SHROOM4 and DGKK may represent a new syndromic X-linked ID critical region associated with mild to severe ID, speech delay +/- dysarthria, attention deficit disorder, precocious puberty, constipation, and motor delay. We frequently observed foot abnormalities, 5th finger clinodactyly, tapering fingers, constipation, and exercise intolerance in patients with duplications of these two genes. Regarding duplications including the proximal region, our observations agree with previous studies, which have found associations with intellectual disability. In addition, expressive language delay, failure to thrive, motor delay, and 5th finger clinodactyly were also frequently observed in patients with the proximal duplication. © 2015 Wiley Periodicals, Inc.

  9. Performance improvement of multi-stage pulse tube cryocoolers with a self-precooled pulse tube

    NASA Astrophysics Data System (ADS)

    Qiu, L. M.; Zhi, X. Q.; Han, L.; Cao, Q.; Gan, Z. H.

    2012-10-01

    Reducing the pulse tube losses is significant for improving the cooling performance of pulse tube cryocoolers (PTCs) in particular for multi-stage ones, although ignored to a certain extent. A simple method called self-precooled pulse tube for multi-stage PTCs is comprehensively studied in order to reduce the entropy flow inside the pulse tube. Different from the complex multi-bypass or extra cryocooler or cryogens for precooling, the key of the idea is to directly precool some part of the lower stage pulse tube by using a small amount of cooling power from the upper stage through a thermal bridge. A two-stage separate Stirling PTC was chosen to demonstrate the effects of self-precooled pulse tube. Theoretical calculation showed that both the precooling temperature and position of the pulse tube affected the performance of the cryocooler. The experiment results showed that the cooling performance of the second stage with self-precooled pulse tube was remarkably improved as the bottom temperature decreased from 26.60 K to 18.02 K. The cooling power was notably increased with minor performance reduction of the first stage. By further optimizing the operation parameters, a no-load temperature of 15.87 K was achieved, which is the lowest temperature ever obtained by a two-stage Stirling PTC with only an inertance shifter. The study proves that the precooled pulse tube can help hot end heat exchanger reject the heat inside pulse tube, reduce the heat losses of the cold end and consequently improve the cooling performance of the cryocooler.

  10. A new high current laboratory and pulsed homopolar generator power supply at the University of Texas

    NASA Astrophysics Data System (ADS)

    Floyd, J. E.; Aanstoos, T. A.

    1984-03-01

    The University of Texas at Austin is constructing a facility for research in pulse power technology for the Center for Electromechanics at the Balcones Research Center. The facility, designed to support high-current experiments, will be powered by six homopolar generators, each rated at 10 MJ and arranged to allow matching the requirements of resistive and inductive loads at various voltage and current combinations. Topics covered include the high bay, the power supply configuration and parameters, the speed and field control, and the magnetic circuit. Also considered are the removable air-cooled brushes, the water-cooled field coils, the hydraulic motor sizing and direct coupling, the low-impedance removable field coils, and the hydrostatic bearing design.

  11. Ultrashort pulse CPA-free Ho:YLF linear amplifier

    NASA Astrophysics Data System (ADS)

    Hinkelmann, Moritz; Wandt, Dieter; Morgner, Uwe; Neumann, Jörg; Kracht, Dietmar

    2018-02-01

    We present CPA-free linear amplification of 6:3 ps pulses in Ho:YLF crystals up to 100 μJ pulse energy at 10 kHz repetition rate. The seed pulses at a wavelength of 2:05 μm are provided by a Ho-based all-fiber system consisting of a soliton oscillator and a subsequent pre-amplifier followed by a free-space AOM as pulse-picker. Considering the achieved pulse peak power at MW-level, this system is a powerful tool for efficient pumping of parametric amplifiers addressing the highly demanded mid-IR spectral region. In detailed numerical simulations we verified our experimental results and discuss scaling options for pulse duration and energy.

  12. Enhancement cavities for zero-offset-frequency pulse trains.

    PubMed

    Holzberger, S; Lilienfein, N; Trubetskov, M; Carstens, H; Lücking, F; Pervak, V; Krausz, F; Pupeza, I

    2015-05-15

    The optimal enhancement of broadband optical pulses in a passive resonator requires a seeding pulse train with a specific carrier-envelope-offset frequency. Here, we control the phase of the cavity mirrors to tune the offset frequency for which a given comb is optimally enhanced. This enables the enhancement of a zero-offset-frequency train of sub-30-fs pulses to multi-kW average powers. The combination of pulse duration, power, and zero phase slip constitutes a crucial step toward the generation of attosecond pulses at multi-10-MHz repetition rates. In addition, this control affords the enhancement of pulses generated by difference-frequency mixing, e.g., for mid-infrared spectroscopy.

  13. CIDME: Short distances measured with long chirp pulses.

    PubMed

    Doll, Andrin; Qi, Mian; Godt, Adelheid; Jeschke, Gunnar

    2016-12-01

    Frequency-swept pulses have recently been introduced as pump pulses into double electron-electron resonance (DEER) experiments. A limitation of this approach is that the pump pulses need to be short in comparison to dipolar evolution periods. The "chirp-induced dipolar modulation enhancement" (CIDME) pulse sequence introduced in this work circumvents this limitation by means of longitudinal storage during the application of one single or two consecutive pump pulses. The resulting six-pulse sequence is closely related to the five-pulse "relaxation-induced dipolar modulation enhancement" (RIDME) pulse sequence: While dipolar modulation in RIDME is due to stochastic spin flips during longitudinal storage, modulation in CIDME is due to the pump pulse during longitudinal storage. Experimentally, CIDME is examined for Gd-Gd and nitroxide-nitroxide distance determination using a high-power Q-band spectrometer. Since longitudinal storage results in a 50% signal loss, comparisons between DEER using short chirp pump pulses of 64ns duration and CIDME using longer pump pulses are in favor of DEER. While the lower sensitivity restrains the applicability of CIDME for routine distance determination on high-power spectrometers, this result is not to be generalized to spectrometers having lower power and to specialized "non-routine" applications or different types of spin labels. In particular, the advantage of prolonged CIDME pump pulses is demonstrated for experiments at large frequency offset between the pumped and observed spins. At a frequency separation of 1GHz, where broadening due to dipolar pseudo-secular contributions becomes largely suppressed, a Gd-Gd modulation depth larger than 10% is achieved. Moreover, a CIDME experiment at deliberately reduced power underlines the potential of the new technique for spectrometers with lower power, as often encountered at higher microwave frequencies. With longitudinal storage times T below 10μs, however, CIDME appears rather

  14. Multi-mJ energy extraction using Yb-fiber based coherent pulse stacking amplification of fs pulses (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ruppe, John M.; Pei, Hanzhang; Chen, Siyun; Sheikhsofla, Morteza; Wilcox, Russell B.; Nees, John A.; Galvanauskas, Almantas

    2017-03-01

    We report multi-mJ energy (>5mJ) extraction from femtosecond-pulse Yb-doped fiber CPA using coherent pulse stacking amplification (CPSA) technique. This high energy extraction has been enabled by amplifying 10's of nanosecond long pulse sequence, and by using 85-µm core Yb-doped CCC fiber based power amplification stage. The CPSA system consists of 1-GHz repetition rate mode-locked fiber oscillator, followed by a pair of fast phase and amplitude electro-optic modulators, a diffraction-grating based pulse stretcher, a fiber amplifier chain, a GTI-cavity based pulse stacker, and a diffraction grating pulse compressor. Electro-optic modulators are used to carve out from the 1-GHz mode-locked pulse train an amplitude and phase modulated pulse burst, which after stretching and amplification, becomes equal-amplitude pulse burst consisting of 27 stretched pulses, each approximately 1-ns long. Initial pulse-burst shaping accounts for the strong amplifier saturation effects, so that it is compensated at the power amplifier output. This 27-pulse burst is then coherently stacked into a single pulse using a multiplexed sequence of 5 GTI cavities. The compact-footprint 4+1 multiplexed pulse stacker consists of 4 cavities having rountrip of 1 ns, and one Herriott-cell folded cavity - with 9ns roundtrip. After stacking, stretched pulses are compressed down to the bandwidth-limited 300 fs duration using a standard diffraction-grating pulse compressor.

  15. Single and Multi-Pulse Low-Energy Conical Theta Pinch Inductive Pulsed Plasma Thruster Performance

    NASA Technical Reports Server (NTRS)

    Hallock, Ashley K.; Martin, Adam; Polzin, Kurt; Kimberlin, Adam; Eskridge, Richard

    2013-01-01

    Fabricated and tested CTP IPPTs at cone angles of 20deg, 38deg, and 60deg, and performed direct single-pulse impulse bit measurements with continuous gas flow. Single pulse performance highest for 38deg angle with impulse bit of approx.1 mN-s for both argon and xenon. Estimated efficiencies low, but not unexpectedly so based on historical data trends and the direction of the force vector in the CTP. Capacitor charging system assembled to provide rapid recharging of capacitor bank, permitting repetition-rate operation. IPPT operated at repetition-rate of 5 Hz, at maximum average power of 2.5 kW, representing to our knowledge the highest average power for a repetitively-pulsed thruster. Average thrust in repetition-rate mode (at 5 kV, 75 sccm argon) was greater than simply multiplying the single-pulse impulse bit and the repetition rate.

  16. Extreme-phenotype genome-wide association study (XP-GWAS): a method for identifying trait-associated variants by sequencing pools of individuals selected from a diversity panel.

    PubMed

    Yang, Jinliang; Jiang, Haiying; Yeh, Cheng-Ting; Yu, Jianming; Jeddeloh, Jeffrey A; Nettleton, Dan; Schnable, Patrick S

    2015-11-01

    Although approaches for performing genome-wide association studies (GWAS) are well developed, conventional GWAS requires high-density genotyping of large numbers of individuals from a diversity panel. Here we report a method for performing GWAS that does not require genotyping of large numbers of individuals. Instead XP-GWAS (extreme-phenotype GWAS) relies on genotyping pools of individuals from a diversity panel that have extreme phenotypes. This analysis measures allele frequencies in the extreme pools, enabling discovery of associations between genetic variants and traits of interest. This method was evaluated in maize (Zea mays) using the well-characterized kernel row number trait, which was selected to enable comparisons between the results of XP-GWAS and conventional GWAS. An exome-sequencing strategy was used to focus sequencing resources on genes and their flanking regions. A total of 0.94 million variants were identified and served as evaluation markers; comparisons among pools showed that 145 of these variants were statistically associated with the kernel row number phenotype. These trait-associated variants were significantly enriched in regions identified by conventional GWAS. XP-GWAS was able to resolve several linked QTL and detect trait-associated variants within a single gene under a QTL peak. XP-GWAS is expected to be particularly valuable for detecting genes or alleles responsible for quantitative variation in species for which extensive genotyping resources are not available, such as wild progenitors of crops, orphan crops, and other poorly characterized species such as those of ecological interest. © 2015 The Authors The Plant Journal published by Society for Experimental Biology and John Wiley & Sons Ltd.

  17. Does the Fuhrman or World Health Organization/International Society of Urological Pathology Grading System Apply to the Xp11.2 Translocation Renal Cell Carcinoma?: A 10-Year Single-Center Study.

    PubMed

    Liu, Ning; Gan, Weidong; Qu, Feng; Wang, Zhen; Zhuang, Wenyuan; Agizamhan, Sezim; Xu, Linfeng; Yin, Juanjuan; Guo, Hongqian; Li, Dongmei

    2018-04-01

    The Fuhrman and World Health Organization/International Society of Urological Pathology (WHO/ISUP) grading systems are widely used to predict survival for patients with conventional renal cell carcinoma. To determine the validity of nuclear grading systems (both the Fuhrman and the WHO/ISUP) and the individual components of the Fuhrman grading system in predicting the prognosis of Xp11.2 translocation renal cell carcinoma (Xp11.2 tRCC), we identified and followed up 47 patients with Xp11.2 tRCC in our center from January 2007 to June 2017. The Fuhrman and WHO/ISUP grading was reassigned by two pathologists. Nuclear size and shape were determined for each case based on the greatest degree of nuclear pleomorphism using image analysis software. Univariate and multivariate analyses were performed to evaluate the capacity of the grading systems and nuclear parameters to predict overall survival and progression-free survival. On univariate Cox regression analysis, the parameters of nuclear size were associated significantly with overall survival and progression-free survival, whereas the grading systems and the parameters of nuclear shape failed to reach a significant correlation. On multivariate analysis, however, none of the parameters was associated independently with survival. Our findings indicate that neither the Fuhrman nor the WHO/ISUP grading system is applicable to Xp11.2 tRCC. The assessment of nuclear size instead may be novel outcome predictors for patients with Xp11.2 tRCC. Copyright © 2018 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  18. International magnetic pulse compression

    NASA Astrophysics Data System (ADS)

    Kirbie, H. C.; Newton, M. A.; Siemens, P. D.

    1991-04-01

    Although pulsed-power engineering traditionally has been practiced by a fairly small, close community in the areas of defense and energy research, it is becoming more common in high-power, high-energy commercial pursuits such as material processing and lasers. This paper is a synopsis of the Feb. 12-14, 1990 workshop on magnetic switching as it applies primarily to pulse compression (power transformation). During the course of the Workshop at Granlibakken, a great deal of information was amassed and a keen insight into both the problems and opportunities as to the use of this switching approach was developed. The segmented workshop format proved ideal for identifying key aspects affecting optimum performance in a variety of applications. Individual groups of experts addressed network and system modeling, magnetic materials, power conditioning, core cooling and dielectrics, and finally circuits and application. At the end, they came together to consolidate their input and formulate the workshop's conclusions, identifying roadblocks or suggesting research projects, particularly as they apply to magnetic switching's trump card - its high-average-power-handling capability (at least on a burst-mode basis). The workshop was especially productive both in the quality and quantity of information transfer in an environment conducive to a free and open exchange of ideas. We will not delve into the organization proper of this meeting, rather we wish to commend to the interested reader this volume, which provides the definitive and most up-to-date compilation on the subject of magnetic pulse compression from underlying principles to current state of the art as well as the prognosis for the future of magnetic pulse compression as a consensus of the workshop's organizers and participants.

  19. Conducted noise analysis and protection of 45 kJ/s, ±50 kV capacitor charging power supply when interfaced with repetitive Marx based pulse power system.

    PubMed

    Naresh, P; Patel, Ankur; Sharma, Archana

    2015-09-01

    Pulse power systems with highly dynamic loads like klystron, backward wave oscillator (BWO), and magnetron generate highly dynamic noise. This noise leads to frequent failure of controlled switches in the inverter stage of charging power supply. Designing a reliable and compatible power supply for pulse power applications is always a tricky job when charging rate is in multiples of 10 kJ/s. A ±50 kV and 45 kJ/s capacitor charging power supply based on 4th order LCLC resonant topology has been developed for a 10 Hz repetitive Marx based system. Conditions for load independent constant current and zero current switching (ZCS) are derived mathematically. Noise generated at load end due to dynamic load is tackled effectively and reduction in magnitude noise voltage is achieved by providing shielding between primary and secondary of high voltage high frequency transformer and with LCLC low pass filter. Shielding scales down the ratio between coupling capacitance (Cc) and the collector-emitter capacitance of insulated gate bi-polar transistor switch, which in turn reduces the common mode noise voltage magnitude. The proposed 4th order LCLC resonant network acts as a low pass filter for differential mode noise in the reverse direction (from load to source). Power supply has been tested repeatedly with 5 Hz repetition rate with repetitive Marx based system connected with BWO load working fine without failure of single switch in the inverter stage.

  20. Conducted noise analysis and protection of 45 kJ/s, ±50 kV capacitor charging power supply when interfaced with repetitive Marx based pulse power system

    NASA Astrophysics Data System (ADS)

    Naresh, P.; Patel, Ankur; Sharma, Archana

    2015-09-01

    Pulse power systems with highly dynamic loads like klystron, backward wave oscillator (BWO), and magnetron generate highly dynamic noise. This noise leads to frequent failure of controlled switches in the inverter stage of charging power supply. Designing a reliable and compatible power supply for pulse power applications is always a tricky job when charging rate is in multiples of 10 kJ/s. A ±50 kV and 45 kJ/s capacitor charging power supply based on 4th order LCLC resonant topology has been developed for a 10 Hz repetitive Marx based system. Conditions for load independent constant current and zero current switching (ZCS) are derived mathematically. Noise generated at load end due to dynamic load is tackled effectively and reduction in magnitude noise voltage is achieved by providing shielding between primary and secondary of high voltage high frequency transformer and with LCLC low pass filter. Shielding scales down the ratio between coupling capacitance (Cc) and the collector-emitter capacitance of insulated gate bi-polar transistor switch, which in turn reduces the common mode noise voltage magnitude. The proposed 4th order LCLC resonant network acts as a low pass filter for differential mode noise in the reverse direction (from load to source). Power supply has been tested repeatedly with 5 Hz repetition rate with repetitive Marx based system connected with BWO load working fine without failure of single switch in the inverter stage.

  1. Towards coherent combining of X-band high power microwaves: phase-locked long pulse radiations by a relativistic triaxial klystron amplifier

    PubMed Central

    Ju, Jinchuan; Zhang, Jun; Qi, Zumin; Yang, Jianhua; Shu, Ting; Zhang, Jiande; Zhong, Huihuang

    2016-01-01

    The radio-frequency breakdown due to ultrahigh electric field strength essentially limits power handling capability of an individual high power microwave (HPM) generator, and this issue becomes more challenging for high frequency bands. Coherent power combining therefore provides an alternative approach to achieve an equivalent peak power of the order of ∼100 GW, which consequently provides opportunities to explore microwave related physics at extremes. The triaxial klystron amplifier (TKA) is a promising candidate for coherent power combing in high frequency bands owing to its intrinsic merit of high power capacity, nevertheless phase-locked long pulse radiation from TKA has not yet been obtained experimentally as the coaxial structure of TKA can easily lead to self-excitation of parasitic modes. In this paper, we present investigations into an X-band TKA capable of producing 1.1 GW HPMs with pulse duration of about 103 ns at the frequency of 9.375 GHz in experiment. Furthermore, the shot-to-shot fluctuation standard deviation of the phase shifts between the input and output microwaves is demonstrated to be less than 10°. The reported achievements open up prospects for accomplishing coherent power combining of X-band HPMs in the near future, and might also excite new development interests concerning high frequency TKAs. PMID:27481661

  2. Radar Range Sidelobe Reduction Using Adaptive Pulse Compression Technique

    NASA Technical Reports Server (NTRS)

    Li, Lihua; Coon, Michael; McLinden, Matthew

    2013-01-01

    Pulse compression has been widely used in radars so that low-power, long RF pulses can be transmitted, rather than a highpower short pulse. Pulse compression radars offer a number of advantages over high-power short pulsed radars, such as no need of high-power RF circuitry, no need of high-voltage electronics, compact size and light weight, better range resolution, and better reliability. However, range sidelobe associated with pulse compression has prevented the use of this technique on spaceborne radars since surface returns detected by range sidelobes may mask the returns from a nearby weak cloud or precipitation particles. Research on adaptive pulse compression was carried out utilizing a field-programmable gate array (FPGA) waveform generation board and a radar transceiver simulator. The results have shown significant improvements in pulse compression sidelobe performance. Microwave and millimeter-wave radars present many technological challenges for Earth and planetary science applications. The traditional tube-based radars use high-voltage power supply/modulators and high-power RF transmitters; therefore, these radars usually have large size, heavy weight, and reliability issues for space and airborne platforms. Pulse compression technology has provided a path toward meeting many of these radar challenges. Recent advances in digital waveform generation, digital receivers, and solid-state power amplifiers have opened a new era for applying pulse compression to the development of compact and high-performance airborne and spaceborne remote sensing radars. The primary objective of this innovative effort is to develop and test a new pulse compression technique to achieve ultrarange sidelobes so that this technique can be applied to spaceborne, airborne, and ground-based remote sensing radars to meet future science requirements. By using digital waveform generation, digital receiver, and solid-state power amplifier technologies, this improved pulse compression

  3. Broadband low-dispersion low-nonlinearity photonic crystal fiber dedicated to near-infrared high-power femtosecond pulse delivery

    NASA Astrophysics Data System (ADS)

    Hoang, Van Thuy; Siwicki, Bartłomiej; Franczyk, Marcin; Stępniewski, Grzegorz; Van, Hieu Le; Long, Van Cao; Klimczak, Mariusz; Buczyński, Ryszard

    2018-05-01

    A low-dispersion and low-nonlinearity silica photonic crystal fiber is designed and developed. The investigated fiber is effectively single-mode and has low dispersion -20 to 40 ps/nm/km in the 1-1.7 μm wavelength range. The silica PCF can withstand a 1017 nm QCW laser beam with a maximum tested power of 9.1 W. The investigated PCF with NA = 0.15 is suggested as a promising medium for a high-power femtosecond undistorted pulse delivery in the near-infrared region.

  4. An Xp11.2 translocation renal cell carcinoma with SMARCB1 (INI1) inactivation in adult end-stage renal disease: a case report.

    PubMed

    Yu, Lu; Li, Jun; Xu, Sanpeng; Navia Miranda, Mariajose; Wang, Guoping; Duan, Yaqi

    2016-10-12

    Xp11.2 translocation/transcription factor E3 (TFE3) rearrangement renal cell carcinoma (RCC) is a rare subtype of RCC with limited clinical and pathological data. Here we present an unusual high-grade Xp11.2 translocation RCC with a rhabdoid feature and SMARCB1 (INI1) inactivation in a 40-year-old man with end-stage kidney disease. The histological examination of the dissected left renal tumor showed an organoid architecture of the eosinophilic or clear neoplastic cells with necrosis and high mitotic activity. In some areas, non-adhesive tumor cells with eccentric nuclei were observed. Immunohistochemically (IHC), the tumor cells are positive for TFE3 and the renal tubular markers (PAX2 and PAX8), and completely negative for SMARCB1, an oncosuppressor protein. Break-apart florescence in situ hybridization and reverse transcription polymerase chain reaction confirmed TFE3 rearrangement on Xp11.2 and the presence of ASPSCR1-TFE3 fusion gene. DNA sequencing revealed a frameshift mutation in exon 4 of SMARCB1 gene. It is important to recognize this rare RCC with both TFE3 rearrangement and SMARCB1 inactivation, as the prognosis and therapeutic strategies, particularly targeted therapies for such tumors, might be different.

  5. Pulsed thermionic converter study

    NASA Technical Reports Server (NTRS)

    1976-01-01

    A nuclear electric propulsion concept using a thermionic reactor inductively coupled to a magnetoplasmadynamic accelerator (MPD arc jet) is described, and the results of preliminary analyses are presented. In this system, the MPD thruster operates intermittently at higher voltages and power levels than the thermionic generating unit. A typical thrust pulse from the MPD arc jet is characterized by power levels of 1 to 4 MWe, a duration of 1 msec, and a duty cycle of approximately 20%. The thermionic generating unit operates continuously but with a lower power level of approximately 0.4 MWe. Energy storage between thrust pulses is provided by building up a large current in an inductor using the output of the thermionic converter array. Periodically, the charging current is interrupted, and the energy stored in the magnetic field of the inductor is utilized for a short duration thrust pulse. The results of the preliminary analysis show that a coupling effectiveness of approximately 85 to 90% is feasible for a nominal 400 KWe system with an inductive unit suitable for a flight vehicle.

  6. Binary power multiplier for electromagnetic energy

    DOEpatents

    Farkas, Zoltan D.

    1988-01-01

    A technique for converting electromagnetic pulses to higher power amplitude and shorter duration, in binary multiples, splits an input pulse into two channels, and subjects the pulses in the two channels to a number of binary pulse compression operations. Each pulse compression operation entails combining the pulses in both input channels and selectively steering the combined power to one output channel during the leading half of the pulses and to the other output channel during the trailing half of the pulses, and then delaying the pulse in the first output channel by an amount equal to half the initial pulse duration. Apparatus for carrying out each of the binary multiplication operation preferably includes a four-port coupler (such as a 3 dB hybrid), which operates on power inputs at a pair of input ports by directing the combined power to either of a pair of output ports, depending on the relative phase of the inputs. Therefore, by appropriately phase coding the pulses prior to any of the pulse compression stages, the entire pulse compression (with associated binary power multiplication) can be carried out solely with passive elements.

  7. Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments.

    PubMed

    Elnaghy, Amr; Elsaka, Shaymaa

    2018-04-01

    The aims of this study were to assess and compare the resistance to cyclic fatigue of XP-endo Shaper (XPS; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments with TRUShape (TRS; Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), HyFlex CM (HCM; Coltene, Cuyahoga Falls, OH, USA), Vortex Blue (VB; Dentsply Tulsa Dental Specialties), and iRace (iR; FKG Dentaire) nickel-titanium rotary instruments at body temperature. Size 30, 0.01 taper of XPS, size 30, 0.04 taper of HCM, VB, iR, and size 30, 0.06 taper of TRS instruments were immersed in saline at 37 ± 1 °C during cyclic fatigue testing. The instruments were tested with 60° angle of curvature and a 3-mm radius of curvature. The number of cycles to failure (NCF) was calculated and the length of the fractured segment was measured. Fractographic examination of the fractured surface was performed using a scanning electron microscope. The data were analyzed statistically using Kruskal-Wallis H test and Mann-Whitney U tests. Statistical significance was set at P < 0.05. XPS had a significantly greater NCF compared with the other instruments (P < 0.001). The topographic appearance of the fracture surfaces of tested instruments revealed ductile fracture of cyclic fatigue failure. XPS instruments exhibited greater cyclic fatigue resistance compared with the other tested instruments. XP-endo Shaper instruments could be used more safely in curved canals due to their higher fatigue resistance.

  8. Quasisubharmonic vibrations in metal plates excited by high-power ultrasonic pulses

    NASA Astrophysics Data System (ADS)

    Chen, Zhao-jiang; Zhang, Shu-yi; Zheng, Kai; Kuo, Pao-kuang

    2009-07-01

    Strongly nonlinear vibration phenomena in metal plates excited by high-power ultrasonic pulses in different conditions are studied experimentally and theoretically. The experimental conditions for generating quasisubharmonics and subharmonics are found and discussed. The plate vibrations are characterized by waveforms, frequency spectra, pseudostate portraits, and Poincaré maps. Then, a three-degree-of-freedom vibroimpact-dynamic model is presented to explore the generation mechanisms of the quasisubharmonic and subharmonic vibrations in the plates. According to the model, the intermittent contact-impact forces caused by the interactions between the transducer horn tip and the plate are considered as the main source for generating the complex nonlinear vibration in the plate. The numerical calculation results can explain reasonably the observed experimental phenomena.

  9. Field-Distortion Air-Insulated Switches for Next-Generation Pulsed-Power Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wisher, Matthew Louis; Johns, Owen M.; Breden, Eric Wayne

    We have developed two advanced designs of a field-distortion air-insulated spark-gap switch that reduce the size of a linear-transformer-driver (LTD) brick. Both designs operate at 200 kV and a peak current of ~50 kA. At these parameters, both achieve a jitter of less than 2 ns and a prefire rate of ~0.1% over 5000 shots. We have reduced the number of switch parts and assembly steps, which has resulted in a more uniform, design-driven assembly process. We will characterize the performance of tungsten-copper and graphite electrodes, and two different electrode geometries. The new switch designs will substantially improve the electricalmore » and operational performance of next-generation pulsed-power accelerators.« less

  10. Clinical characteristics of XP11.2 translocation/TFE3 gene fusion renal cell carcinoma: a systematic review and meta-analysis of observational studies.

    PubMed

    Cheng, Xiangming; Gan, Weidong; Zhang, Gutian; Li, Xiaogong; Guo, Hongqian

    2016-07-11

    Renal cell carcinoma (RCC) associated with Xp11.2 translocation/TFE3 gene fusion (Xp11.2 RCC) is a rare subtype of RCC which is firstly described as a distinct entity in 2004 so that clinical characteristics of Xp11.2 RCC in different gender and age are unknown. The purpose of systematic review and meta-analysis is to provide a comprehensive assessment on them. MEDLINE, EMBASE and Cochrane databases were searched for studies which evaluate the clinical characteristics of Xp11.2 RCC. The literature published between July 2004 and May 2014 was searched. A total of 15 studies with 147 participants were included. The meta-analysis demonstrated that number of patients of all age in female was higher than in male with pooled OR of 3.93(95 % CI = 1.66-9.34). However, incidence of distant metastases (OR = 0.34, 95 % CI = 0.12-1.57) and lymphatic metastases (OR = 0.51, 95 % CI = 0.14-1.91), tumor stage (OR = 0.85, 95 % CI = 0.34-2.15) and overall survival (OS) (OR = 0.46, 95 % CI = 0.05-4.34) between male and female were comparable. Incidence in female was higher than in male with pooled OR of 5.13(95 % CI = 1.67-15.72) in adults, while in children no gender-related predominance (OR = 1.19, 95 % CI = 0.38-3.72) was observed. In addition, incidence of distant metastases (OR = 1.00, 95 % CI = 0.13-7.84) and lymphatic metastases (OR = 1.00, 95 % CI = 0.07-13.67) and tumor stage (OR = 1.94, 95 % CI = 0.20-19.03) between children and adults were comparable. Survival curves presented comparable outcomes between male and female (P = 0.707) as well as between children and adults (P = 0.383). Female patients with Xp11.2 RCC in adults exhibit a high incidence compared to male, but not in children. Comparable clinical characteristics including incidence of distant and lymphatic metastases, tumor stage and prognosis is presented between male and female as well as between children and adults.

  11. Newly designed break-apart and ASPL-TFE3 dual-fusion FISH assay are useful in diagnosing Xp11.2 translocation renal cell carcinoma and ASPL-TFE3 renal cell carcinoma: a STARD-compliant article.

    PubMed

    Chen, Xiancheng; Yang, Yang; Gan, Weidong; Xu, Linfeng; Ye, Qing; Guo, Hongqian

    2015-05-01

    The diagnosis of Xp11.2 translocation renal cell carcinoma (tRCC), which relies on morphology and immunohistochemistry (IHC), is often either missed in the diagnosis or misdiagnosed. To improve the accuracy of diagnosis of Xp11.2 tRCC and ASPL-TFE3 renal cell carcinoma (RCC), we investigated newly designed fluorescence in situ hybridization (FISH) probes (diagnostic accuracy study).Based on the genetic characteristics of Xp11.2 tRCC and the ASPL-TFE3 RCC, a new break-apart TFE3 FISH probe and an ASPL-TFE3 dual-fusion FISH probe were designed and applied to 65 patients with RCC who were <45 years old or showed suspicious microscopic features of Xp11.2 tRCC in our hospital. To test the accuracy of the probes, we further performed reverse transcriptase-polymerase chain reaction (PCR) on 8 cases for which frozen tissues were available.Among the 65 cases diagnosed with RCC, TFE3 IHC was positive in 24 cases. Twenty-two cases were confirmed as Xp11.2 tRCC by break-apart TFE3 FISH, and 6 of these cases were further diagnosed as ASPL-TFE3 RCC by ASPL-TFE3 dual-fusion FISH detection. Importantly, reverse transcriptase-PCR showed concordant results with the results of FISH assay in the 8 available frozen cases.The break-apart and ASPL-TFE3 dual-fusion FISH assay can accurately detect the translocation of the TFE3 gene and ASPL-TFE3 fusion gene and can thus serve as a valid complementary method for diagnosing Xp11.2 tRCC and ASPL-TFE3 RCC.

  12. Ultrafast optomechanical pulse picking

    NASA Astrophysics Data System (ADS)

    Lilienfein, Nikolai; Holzberger, Simon; Pupeza, Ioachim

    2017-01-01

    State-of-the-art optical switches for coupling pulses into and/or out of resonators are based on either the electro-optic or the acousto-optic effect in transmissive elements. In high-power applications, the damage threshold and other nonlinear and thermal effects in these elements impede further improvements in pulse energy, duration, and average power. We propose a new optomechanical switching concept which is based solely on reflective elements and is suitable for switching times down to the ten-nanosecond range. To this end, an isolated section of a beam path is moved in a system comprising mirrors rotating at a high angular velocity and stationary imaging mirrors, without affecting the propagation of the beam thereafter. We discuss three variants of the concept and exemplify practical parameters for its application in regenerative amplifiers and stack-and-dump enhancement cavities. We find that optomechanical pulse picking has the potential to achieve switching rates of up to a few tens of kilohertz while supporting pulse energies of up to several joules.

  13. Performance study of highly efficient 520 W average power long pulse ceramic Nd:YAG rod laser

    NASA Astrophysics Data System (ADS)

    Choubey, Ambar; Vishwakarma, S. C.; Ali, Sabir; Jain, R. K.; Upadhyaya, B. N.; Oak, S. M.

    2013-10-01

    We report the performance study of a 2% atomic doped ceramic Nd:YAG rod for long pulse laser operation in the millisecond regime with pulse duration in the range of 0.5-20 ms. A maximum average output power of 520 W with 180 J maximum pulse energy has been achieved with a slope efficiency of 5.4% using a dual rod configuration, which is the highest for typical lamp pumped ceramic Nd:YAG lasers. The laser output characteristics of the ceramic Nd:YAG rod were revealed to be nearly equivalent or superior to those of high-quality single crystal Nd:YAG rod. The laser pump chamber and resonator were designed and optimized to achieve a high efficiency and good beam quality with a beam parameter product of 16 mm mrad (M2˜47). The laser output beam was efficiently coupled through a 400 μm core diameter optical fiber with 90% overall transmission efficiency. This ceramic Nd:YAG laser will be useful for various material processing applications in industry.

  14. Completely explosive ultracompact high-voltage nanosecond pulse-generating system

    NASA Astrophysics Data System (ADS)

    Shkuratov, Sergey I.; Talantsev, Evgueni F.; Baird, Jason; Rose, Millard F.; Shotts, Zachary; Altgilbers, Larry L.; Stults, Allen H.

    2006-04-01

    A conventional pulsed power technology has been combined with an explosive pulsed power technology to produce an autonomous high-voltage power supply. The power supply contained an explosive-driven high-voltage primary power source and a power-conditioning stage. The ultracompact explosive-driven primary power source was based on the physical effect of shock-wave depolarization of high-energy Pb (Zr52Ti48)O3 ferroelectric material. The volume of the energy-carrying ferroelectric elements in the shock-wave ferroelectric generators (SWFEGs) varied from 1.2 to 2.6cm3. The power-conditioning stage was based on the spiral vector inversion generator (VIG). The SWFEG-VIG system demonstrated successful operation and good performance. The amplitude of the output voltage pulse of the SWFEG-VIG system exceeded 90kV, with a rise time of 5.2ns.

  15. Characterization of Wet Air Plasma Jet Powered by Sinusoidal High Voltage and Nanosecond Pulses for Plasma Agricultural Application

    NASA Astrophysics Data System (ADS)

    Takashima, Keisuke; Shimada, Keisuke; Konishi, Hideaki; Kaneko, Toshiro

    2015-09-01

    Not only for the plasma sterilization but also for many of plasma life-science applications, atmospheric pressure plasma devices that allowed us to control its state and reactive species production are deserved to resolve the roles of the chemical species. Influence of the hydroxyl radical and ozone on germination of conidia of a strawberry pathogen is presented. Water addition to air plasma jet significantly improves germination suppression performance, while measured reactive oxygen species (ROS) are reduced. Although the results show a negative correlation between ROS and the germination suppression, this infers the importance of chemical composition generated by plasma. For further control of the plasma product, a plasma jet powered by sinusoidal high voltage and nanosecond pulses is developed and characterized with the voltage-charge Lissajous. Control of breakdown phase and discharge power by pulse-imposed phase is presented. This work is supported by JSPS KAKENHI Grant-in-Aid for Young Scientists (B) Grant Number 15K17480 and Exploratory Research Grant Number 23644199.

  16. Histological examination of the oral mucosa after fractional diode laser irradiation with different power and pulse duration

    NASA Astrophysics Data System (ADS)

    Belikov, Andrey V.; Ermolaeva, Ludmila A.; Korzhevsky, Dmitriy E.; Sergeeva, Elena S.; Semyashkina, Yulia V.; Antropova, Maria M.; Fedotov, Denis Y.; Zaitseva, Maria A.; Kashina, Tatiana V.

    2018-04-01

    Optical and histological methods were used to examination of influence the power and pulse duration of 980-nm diode laser to the dimensions and morphology of tissue around fractional micro injuries created by the radiation of that laser in the oral mucosa of rats in vivo. The power of laser radiation (P) varied in the range of 1÷21 W, and its pulse duration (tp) - in the range 50÷500 ms. Histological examination showed that in the mucosa of the oral cavity after the laser fractional irradiation, there following effects are found: a tissue defect, a transudate in the lumen of ablative micro injury, stretching and compacting effect of the nuclei of the basal epithelium, the disappearance of granules of the keratohialin, destroying the structure of the connective tissue, erythrocyte stasis in the vessels, the disappearance of transverse striation in the muscle fibers in muscle layer. It has been found that ablative micro injury begins to form up at P = 5 W, tp = 100 ms and affects only the epithelial layer of the mucosa. At P = 7 W, tp = 120 ms, the ratio of width to depth of ablative micro injury is 1 : 1, and at P = 10 W, tp = 100 ms, an ablative micro column with ratio of 1 : 1.5 is formed in the epithelial and submucosal layers of the mucosa. The laser effect with P = 15 W, tp = 200 ms leads to lengthening of the ablation micro-column to 1 : 2, with the bottom of the ablative micro column reaching the muscular layer. With a further growth of laser power or pulse duration, the width of the micro injury increases, and the growth of the micro injury depth is slowed down so that the micro column buildup is ceased.

  17. Striation Formation in Cylindrical Liners Made of Various Materials Driven by a 1 MA Pulsed Power Generator

    NASA Astrophysics Data System (ADS)

    Atoyan, Levon; Byvank, Tom; Engelbrecht, Joseph; Greenly, John; Pikuz, Sergei; Potter, William; Shelkovenko, Tania; Kusse, Bruce; Hammer, David

    2016-10-01

    Peterson et al. found on the 20 MA Z machine that, without any applied external axial magnetic field, horizontal striations appear in radiographic images of a metal liner [Phys. Plasmas 19, 092701, 2012], a result that has been reproduced on other pulsed power machines since. In this work we present experimental results of horizontal striations on the 1 MA, 100-200 ns COBRA pulsed power generator [T. A. Shelkovenko et al., Rev. Sci. Instrum. 77, 10F521, 2006]. The pattern is observed in our experiments using extreme ultraviolet imaging, laser imaging, and X-ray backlighting. Using this combination of diagnostics, we were able to view simultaneously the pattern near the liner surface as well as in the higher density portion of the liner, displaying features with different wavelengths. Furthermore, materials such as Al, Cu, and Ti will be used for the liner to determine if the striation formation is affected by the nature of the material. This research is supported by the NNSA Stewardship Sciences Academic Programs under Department of Energy Cooperative Agreement DE-NA0001836 and DOE account DE-NA0002952.

  18. International magnetic pulse compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirbie, H.C.; Newton, M.A.; Siemens, P.D.

    1991-04-01

    Although pulsed-power engineering traditionally has been practiced by a fairly small, close community in the areas of defense and energy research, it is becoming more common in high-power, high-energy commercial pursuits such as material processing and lasers. This paper is a synopsis of the Feb. 12--14, 1990 workshop on magnetic switching as it applies primarily to pulse compression (power transformation). During the course of the Workshop at Granlibakken, a great deal of information was amassed and a keen insight into both the problems and opportunities as to the use of this switching approach was developed. The segmented workshop format provedmore » ideal for identifying key aspects affecting optimum performance in a variety of applications. Individual groups of experts addressed network and system modeling, magnetic materials, power conditioning, core cooling and dielectrics, and finally circuits and application. At the end, they came together to consolidate their input and formulate the workshop's conclusions, identifying roadblocks or suggesting research projects, particularly as they apply to magnetic switching's trump card -- its high-average-power-handling capability (at least on a burst-mode basis). The workshop was especially productive both in the quality and quantity of information transfer in an environment conducive to a free and open exchange of ideas. We will not delve into the organization proper of this meeting, rather we wish to commend to the interested reader this volume, which provides the definitive and most up-to-date compilation on the subject of magnetic pulse compression from underlying principles to current state of the art as well as the prognosis for the future of magnetic pulse compression as a consensus of the workshop's organizers and participants.« less

  19. Mode-locked Yb:YAG thin-disk oscillator with 41 µJ pulse energy at 145 W average infrared power and high power frequency conversion.

    PubMed

    Bauer, Dominik; Zawischa, Ivo; Sutter, Dirk H; Killi, Alexander; Dekorsy, Thomas

    2012-04-23

    We demonstrate the generation of 1.1 ps pulses containing more than 41 µJ of energy directly out of an Yb:YAG thin-disk without any additional amplification stages. The laser oscillator operates in ambient atmosphere with a 3.5 MHz repetition rate and 145 W of average output power at a fundamental wavelength of 1030 nm. An average output power of 91.5 W at 515 nm was obtained by frequency doubling with a conversion efficiency exceeding 65%. Third harmonic generation resulted in 34 W at 343 nm at 34% efficiency. © 2012 Optical Society of America

  20. A study of junction effect transistors and their roles in carbon nanotube field emission cathodes in compact pulsed power applications

    NASA Astrophysics Data System (ADS)

    Shui, Qiong

    This thesis is focusing on a study of junction effect transistors (JFETs) in compact pulsed power applications. Pulsed power usually requires switches with high hold-off voltage, high current, low forward voltage drop, and fast switching speed. 4H-SiC, with a bandgap of 3.26 eV (The bandgap of Si is 1.12eV) and other physical and electrical superior properties, has gained much attention in high power, high temperature and high frequency applications. One topic of this thesis is to evaluate if 4H-SiC JFETs have a potential to replace gas phase switches to make pulsed power system compact and portable. Some other pulsed power applications require cathodes of providing stable, uniform, high electron-beam current. So the other topic of this research is to evaluate if Si JFET-controlled carbon nanotube field emitter cold cathode will provide the necessary e-beam source. In the topic of "4H-SiC JFETs", it focuses on the design and simulation of a novel 4H-SiC normally-off VJFET with high breakdown voltage using the 2-D simulator ATLAS. To ensure realistic simulations, we utilized reasonable physical models and the established parameters as the input into these models. The influence of key design parameters were investigated which would extend pulsed power limitations. After optimizing the key design parameters, with a 50-mum drift region, the predicted breakdown voltage for the VJFET is above 8kV at a leakage current of 1x10-5A/cm2 . The specific on-state resistance is 35 mO·cm 2 at VGS = 2.7 V, and the switching speed is several ns. The simulation results suggest that the 4H-SiC VJFET is a potential candidate for improving switching performance in repetitive pulsed power applications. To evaluate the 4H-SiC VJFETs in pulsed power circuits, we extracted some circuit model parameters from the simulated I-V curves. Those parameters are necessary for circuit simulation program such as SPICE. This method could be used as a test bench without fabricating the devices to