Sample records for xpress point-of-care chemistry

  1. Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer

    PubMed Central

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375

  2. Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.

    PubMed

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.

  3. Accurate PCR Detection of Influenza A/B and Respiratory Syncytial Viruses by Use of Cepheid Xpert Flu+RSV Xpress Assay in Point-of-Care Settings: Comparison to Prodesse ProFlu.

    PubMed

    Cohen, Daniel M; Kline, Jennifer; May, Larissa S; Harnett, Glenn Eric; Gibson, Jane; Liang, Stephen Y; Rafique, Zubaid; Rodriguez, Carina A; McGann, Kevin M; Gaydos, Charlotte A; Mayne, Donna; Phillips, David; Cohen, Jason

    2018-02-01

    The Xpert Flu+RSV Xpress Assay is a fast, automated in vitro diagnostic test for qualitative detection and differentiation of influenza A and B viruses and respiratory syncytial virus (RSV) performed on the Cepheid GeneXpert Xpress System. The objective of this study was to establish performance characteristics of the Xpert Flu+RSV Xpress Assay compared to those of the Prodesse ProFlu+ real-time reverse transcription-PCR (RT-PCR) assay (ProFlu+) for the detection of influenza A and B viruses as well as RSV in a Clinical Laboratory Improvement Amendments (CLIA)-waived (CW) setting. Overall, the assay, using fresh and frozen nasopharyngeal (NP) swabs, demonstrated high concordance with results of the ProFlu+ assay in the combined CW and non-CW settings with positive percent agreements (PPA) (100%, 100%, and 97.1%) and negative percent agreements (NPA) (95.2%, 99.5%, and 99.6%) for influenza A and B viruses and RSV, respectively. In conclusion, this multicenter study using the Cepheid Xpert Flu+RSV Xpress Assay demonstrated high sensitivities and specificities for influenza A and B viruses and RSV in ∼60 min for use at the point-of-care in the CW setting. Copyright © 2018 American Society for Microbiology.

  4. 76 FR 66354 - DesertXpress Enterprises, LLC and DesertXpress HSR Corporation-Construction and Operation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-26

    ... DEPARTMENT OF TRANSPORTATION Surface Transportation Board [Docket No. FD 35544] DesertXpress Enterprises, LLC and DesertXpress HSR Corporation-- Construction and Operation Exemption--in Victorville, CA... requirements of 49 U.S.C. 10901 for DesertXpress Enterprises, LLC and its subsidiary (DXE) to build and operate...

  5. Liver function testing on the Abaxis Piccolo Xpress: Use in Ebola virus disease protocols.

    PubMed

    Owen, William E; Caron, Justin E; Genzen, Jonathan R

    2015-06-15

    Laboratories that choose a point-of-care approach for liver function testing in patients undergoing evaluation for Ebola virus disease (EVD) have few options to choose from. The primary objective of this study was to conduct a performance characterization of a Clinical Laboratory Improvement Amendments (CLIA)-waived liver function panel on the Abaxis Piccolo® Xpress chemistry analyzer. The secondary objectives were to evaluate multiple specimen types, characterize whole blood specimen stability, and validate disposable exact transfer pipettes. Our final objective was to assess instrument airflow from a biosafety perspective. An instrument performance characterization, including precision, linearity, accuracy, reference interval verification, and specimen type evaluation was conducted using Liver Panel Plus reagent discs on the Piccolo® Xpress. All assays demonstrated acceptable linearity (slopes, 0.938-1.061; observed error, 0.8-6.3%). Assay precision was 0.0-3.6% (%CV; within-day studies) and 0.9-5.6% (between-day studies). Method comparison experiments (versus Roche cobas c502/c702 chemistry analyzers) showed excellent correlation for most assays, although a few notable differences were observed (Piccolo versus Roche): alkaline phosphatase, -18.6%; amylase, -29.0%; total bilirubin, +0.3mg/dl. Pre-programmed reference intervals were verified except for the alkaline phosphatase (male and female) and alanine aminotransferase (female), which had greater than 10% of results fall below the programmed ranges. Piccolo instrument results were largely consistent across specimen types tested (lithium-heparin whole blood, lithium-heparin plasma, and serum), although some statistical differences were observed for aspartate aminotransferase, gamma glutamyltransferase, and total protein. Whole blood time course studies demonstrated that some analytes (albumin, amylase, and total protein) showed remarkable stability, while others (such as aspartate aminotransferase) showed a

  6. Polygon Pictures in QuarkXPress.

    ERIC Educational Resources Information Center

    Osterer, Irv

    1999-01-01

    Describes an activity where students draw and fill simple and complex shapes by utilizing the polygon tool in QuarkXPress to create graphics. Explains that this activity enables students to learn how to use a variety of functions in the QuarkXPress program. (CMK)

  7. XpressWare Installation User guide

    NASA Astrophysics Data System (ADS)

    Duffey, K. P.

    XpressWare is a set of X terminal software, released by Tektronix Inc, that accommodates the X Window system on a range of host computers. The software comprises boot files (the X server image), configuration files, fonts, and font tools to support the X terminal. The files can be installed on one host or distributed across multiple hosts The purpose of this guide is to present the system or network administrator with a step-by-step account of how to install XpressWare, and how subsequently to configure the X terminals appropriately for the environment in which they operate.

  8. XPRESS: eXascale PRogramming Environment and System Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brightwell, Ron; Sterling, Thomas; Koniges, Alice

    The XPRESS Project is one of four major projects of the DOE Office of Science Advanced Scientific Computing Research X-stack Program initiated in September, 2012. The purpose of XPRESS is to devise an innovative system software stack to enable practical and useful exascale computing around the end of the decade with near-term contributions to efficient and scalable operation of trans-Petaflops performance systems in the next two to three years; both for DOE mission-critical applications. To this end, XPRESS directly addresses critical challenges in computing of efficiency, scalability, and programmability through introspective methods of dynamic adaptive resource management and task scheduling.

  9. 76 FR 18298 - Notice of Availability of a Final Environmental Impact Statement for the DesertXpress High-Speed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-01

    ... Environmental Impact Statement for the DesertXpress High-Speed Passenger Train Project AGENCY: Federal Railroad... for the DesertXpress High-Speed Passenger Train Project (DesertXpress project). FRA is the Lead Agency... and operation of an interstate high-speed passenger train system between Victorville, California and...

  10. eXascale PRogramming Environment and System Software (XPRESS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, Barbara; Gabriel, Edgar

    Exascale systems, with a thousand times the compute capacity of today’s leading edge petascale computers, are expected to emerge during the next decade. Their software systems will need to facilitate the exploitation of exceptional amounts of concurrency in applications, and ensure that jobs continue to run despite the occurrence of system failures and other kinds of hard and soft errors. Adapting computations at runtime to cope with changes in the execution environment, as well as to improve power and performance characteristics, is likely to become the norm. As a result, considerable innovation is required to develop system support to meetmore » the needs of future computing platforms. The XPRESS project aims to develop and prototype a revolutionary software system for extreme-­scale computing for both exascale and strong­scaled problems. The XPRESS collaborative research project will advance the state-­of-­the-­art in high performance computing and enable exascale computing for current and future DOE mission-­critical applications and supporting systems. The goals of the XPRESS research project are to: A. enable exascale performance capability for DOE applications, both current and future, B. develop and deliver a practical computing system software X-­stack, OpenX, for future practical DOE exascale computing systems, and C. provide programming methods and environments for effective means of expressing application and system software for portable exascale system execution.« less

  11. 76 FR 71353 - Notice of Availability of the Record of Decision for the DesertXpress Enterprises, LLC High-Speed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-17

    ..., LLC High-Speed Passenger Train Project AGENCY: Bureau of Land Management, Interior. ACTION: Notice of... (ROD) for the DesertXpress Enterprises, LLC High-Speed Passenger Train Project (DesertXpress Project...-managed lands to build an Electrical Multiple Unit (EMU) high-speed passenger rail line in compliance with...

  12. AXIS: Adult Education eXpress Intercommunication Support. Final Report.

    ERIC Educational Resources Information Center

    Reiff, Tana

    This package includes the final report and selected products of the Adult education eXpress Intercommunication Support (AXIS) project, which was conducted to facilitate communication related to professional development services administered by the Pennsylvania Department of Education's Bureau of Adult Basic and Literacy Education (ABLE) and…

  13. The multidriver: A reliable multicast service using the Xpress Transfer Protocol

    NASA Technical Reports Server (NTRS)

    Dempsey, Bert J.; Fenton, John C.; Weaver, Alfred C.

    1990-01-01

    A reliable multicast facility extends traditional point-to-point virtual circuit reliability to one-to-many communication. Such services can provide more efficient use of network resources, a powerful distributed name binding capability, and reduced latency in multidestination message delivery. These benefits will be especially valuable in real-time environments where reliable multicast can enable new applications and increase the availability and the reliability of data and services. We present a unique multicast service that exploits features in the next-generation, real-time transfer layer protocol, the Xpress Transfer Protocol (XTP). In its reliable mode, the service offers error, flow, and rate-controlled multidestination delivery of arbitrary-sized messages, with provision for the coordination of reliable reverse channels. Performance measurements on a single-segment Proteon ProNET-4 4 Mbps 802.5 token ring with heterogeneous nodes are discussed.

  14. A point-of-care chemistry test for reduction of turnaround and clinical decision time.

    PubMed

    Lee, Eui Jung; Shin, Sang Do; Song, Kyoung Jun; Kim, Seong Chun; Cho, Jin Seong; Lee, Seung Chul; Park, Ju Ok; Cha, Won Chul

    2011-06-01

    Our study compared clinical decision time between patients managed with a point-of-care chemistry test (POCT) and patients managed with the traditional central laboratory test (CLT). This was a randomized controlled multicenter trial in the emergency departments (EDs) of 5 academic teaching hospitals. We randomly assigned patients to POCT or CLT stratified by the Emergency Severity Index. A POCT chemistry analyzer (Piccolo; Abaxis, Inc, Union City, Calif), which is able to test liver panel, renal panel, pancreas enzymes, lipid panel, electrolytes, and blood gases, was set up in each ED. Primary and secondary end point was turnaround time and door-to-clinical-decision time. The total 2323 patients were randomly assigned to the POCT group (n = 1167) or to the CLT group (n = 1156). All of the basic characteristics were similar in the 2 groups. The turnaround time (median, interquartile range [IQR]) of the POCT group was shorter than that of the CLT group (14, 12-19 versus 55, 45-69 minutes; P < .0001). The median (IQR) door-to-clinical-decision time was also shorter in the POCT compared with the CLT group (46, 33-61 versus 86, 68-107 minutes; P < .0001). The proportion of patients who had new decisions within 60 minutes was 72.8% for the POCT group and 12.5% for the CLT group (P < .0001). A POCT chemistry analyzer in the ED shortens the test turnaround and ED clinical decision times compared with CLT. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Tranzit XPress : hazardous material fleet management and monitoring system : evaluation report

    DOT National Transportation Integrated Search

    1997-07-01

    In this report the evaluation performed on the first phase of the Tranzit XPress system is presented. The system comprises of a traffic/safety control center, motor vehicle instrumentation, and a variety of off vehicle tools that communicate with eac...

  16. Point-of-Care Diagnostics for Niche Applications

    PubMed Central

    Cummins, Brian M.; Ligler, Frances S.; Walker, Glenn M.

    2016-01-01

    Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. PMID:26837054

  17. VIDAS Listeria species Xpress (LSX).

    PubMed

    Johnson, Ronald; Mills, John

    2013-01-01

    The AOAC GovVal study compared the VIDAS Listeria species Xpress (LSX) to the Health Products and Food Branch MFHPB-30 reference method for detection of Listeria on stainless steel. The LSX method utilizes a novel and proprietary enrichment media, Listeria Xpress broth, enabling detection of Listeria species in environmental samples with the automated VIDAS in a minimum of 26 h. The LSX method also includes the use of the chromogenic media, chromID Ottaviani Agosti Agar (OAA) and chromID Lmono for confirmation of LSX presumptive results. In previous AOAC validation studies comparing VIDAS LSX to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference methods, the LSX method was approved as AOAC Official Method 2010.02 for the detection of Listeria species in dairy products, vegetables, seafood, raw meats and poultry, and processed meats and poultry, and as AOAC Performance Tested Method 100501 in a variety of foods and on environmental surfaces. The GovVal comparative study included 20 replicate test portions each at two contamination levels for stainless steel where fractionally positive results (5-15 positive results/20 replicate portions tested) were obtained by at least one method at one level. Five uncontaminated controls were included. In the stainless steel artificially contaminated surface study, there were 25 confirmed positives by the VIDAS LSX assay and 22 confirmed positives by the standard culture methods. Chi-square analysis indicated no statistical differences between the VIDAS LSX method and the MFHPB-30 standard methods at the 5% level of significance. Confirmation of presumptive LSX results with the chromogenic OAA and Lmono media was shown to be equivalent to the appropriate reference method agars. The data in this study demonstrate that the VIDAS LSX method is an acceptable alternative method to the MFHPB-30 standard

  18. Point-of-care diagnostics for niche applications.

    PubMed

    Cummins, Brian M; Ligler, Frances S; Walker, Glenn M

    2016-01-01

    Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Software interface for high-speed readout of particle detectors based on the CoaXPress communication standard

    NASA Astrophysics Data System (ADS)

    Hejtmánek, M.; Neue, G.; Voleš, P.

    2015-06-01

    This article is devoted to the software design and development of a high-speed readout application used for interfacing particle detectors via the CoaXPress communication standard. The CoaXPress provides an asymmetric high-speed serial connection over a single coaxial cable. It uses a widely available 75 Ω BNC standard and can operate in various modes with a data throughput ranging from 1.25 Gbps up to 25 Gbps. Moreover, it supports a low speed uplink with a fixed bit rate of 20.833 Mbps, which can be used to control and upload configuration data to the particle detector. The CoaXPress interface is an upcoming standard in medical imaging, therefore its usage promises long-term compatibility and versatility. This work presents an example of how to develop DAQ system for a pixel detector. For this purpose, a flexible DAQ card was developed using the XILINX Spartan 6 FPGA. The DAQ card is connected to the framegrabber FireBird CXP6 Quad, which is plugged in the PCI Express bus of the standard PC. The data transmission was performed between the FPGA and framegrabber card via the standard coaxial cable in communication mode with a bit rate of 3.125 Gbps. Using the Medipix2 Quad pixel detector, the framerate of 100 fps was achieved. The front-end application makes use of the FireBird framegrabber software development kit and is suitable for data acquisition as well as control of the detector through the registers implemented in the FPGA.

  20. Tighter accuracy standards within point-of-care blood glucose monitoring: how six commonly used systems compare.

    PubMed

    Robinson, Charlotte S; Sharp, Patrick

    2012-05-01

    Blood glucose monitoring systems (BGMS) are used in the hospital environment to manage blood glucose levels in patients at the bedside. The International Organization for Standardization (ISO) 15197:2003 standard is currently used by regulatory bodies as a minimum requirement for the performance of BGMS, specific to self-testing. There are calls for the tightening of accuracy requirements and implementation of a standard specifically for point-of-care (POC) BGMS. The accuracy of six commonly used BGMS was assessed in a clinical setting, with 108 patients' finger stick capillary samples. Using the accuracy criteria from the existing standard and a range of tightened accuracy criteria, system performance was compared. Other contributors to system performance have been measured, including hematocrit sensitivity and meter error rates encountered in the clinical setting. Five of the six BGMS evaluated met current accuracy criteria within the ISO 15197 standard. Only the Optium Xceed system had >95% of all readings within a tightened criteria of ±12.5% from the reference at glucose levels ≥72 mg/dl (4 mmol/liter) and ±9 mg/dl (0.5 mmol/liter) at glucose levels <72 mg/dl (4 mmol/liter). The Nova StatStrip Xpress had the greatest number of error messages observed; Optium Xceed the least. OneTouch Ultra2, Nova StatStrip Xpress, Accu-Chek Performa, and Contour TS products were all significantly influenced by blood hematocrit levels. From evidence obtained during this clinical evaluation, the Optium Xceed system is most likely to meet future anticipated accuracy standards for POC BGMS. In this clinical study, the results demonstrated the Optium Xceed product to have the highest level of accuracy, to have the lowest occurrence of error messages, and to be least influenced by blood hematocrit levels. © 2012 Diabetes Technology Society.

  1. Delivering Library Services to Users: A Case Study of the Sooner Xpress Service at the University of Oklahoma

    ERIC Educational Resources Information Center

    Murphy, Molly; Franklin, Shelly; Raia, Ann

    2007-01-01

    Sooner Xpress service arose out of a need to improve and expand services for library users at the University of Oklahoma. After several years of service for our distance education students, a decision was made to expand those services to include all campus and local users in an effort to streamline retrieval services in the library. Both…

  2. [Optimization of Cryptosporidium and Giardia detection in water environment using automatic elution station Filta-Max xpress].

    PubMed

    Matuszewska, Renata; Szczotko, Maciej; Krogulska, Bozena

    2012-01-01

    The presence of parasitic protozoa in drinking water is mostly a result of improperly maintened the water treatment process. Currently, in Poland the testing of Cryptosporidium and Giardia in water as a part of routine monitoring of water is not perform. The aim of this study was the optimization of the method of Cryptosporidium and Giardia detection in water according to the main principles of standard ISO 15553:2006 and using Filta-Max xpress automatic elution station. Preliminary tests were performed on the samples contaminated with oocysts and cysts of reference strains of both parasitic protozoa. Further studies were carried out on environmental samples of surface water sampled directly from the intakes of water (21 samples from Vistula River and 8 samples from Zegrzynski Lake). Filtration process and samples volume reducing were performed using an automatic elution system Filta-Max xpress. Next, samples were purified during immunomagnetic separation process (IMS). Isolated cysts and oocysts were stained with FITC and DAPI and than the microscopic observation using an epifluorescence microscope was carried out. Recovery of parasite protozoa in all contaminated water samples after 9-cycles elution process applied was mean 60.6% for Cryptosporidium oocysts and 36.1% for Giardia cysts. Studies on the environmental surface water samples showed the presence of both parasitic protozoa. Number of detected Giardia cysts ranged from 1.0/10 L up to 4.5/10 L in samples from Zegrzynski Lake and from 1.0/10 L up to 38.9/10 L in samples from Vistula River. Cryptosporidium oocysts were present in 50% of samples from the Zegrzynski Lake and in 47.6% of samples from the Vistula River, and their number in both cases was similar and ranged from 0.5 up to 2.5 oocyst/10 L. The results show that applied procedure is appropriate for detection the presence of parasitic protosoan in water, but when water contains much amount of inorganic matter and suspended solids test method have to

  3. The Xpress Transfer Protocol (XTP): A tutorial (expanded version)

    NASA Technical Reports Server (NTRS)

    Sanders, Robert M.; Weaver, Alfred C.

    1990-01-01

    The Xpress Transfer Protocol (XTP) is a reliable, real-time, light weight transfer layer protocol. Current transport layer protocols such as DoD's Transmission Control Protocol (TCP) and ISO's Transport Protocol (TP) were not designed for the next generation of high speed, interconnected reliable networks such as fiber distributed data interface (FDDI) and the gigabit/second wide area networks. Unlike all previous transport layer protocols, XTP is being designed to be implemented in hardware as a VLSI chip set. By streamlining the protocol, combining the transport and network layers and utilizing the increased speed and parallelization possible with a VLSI implementation, XTP will be able to provide the end-to-end data transmission rates demanded in high speed networks without compromising reliability and functionality. This paper describes the operation of the XTP protocol and in particular, its error, flow and rate control; inter-networking addressing mechanisms; and multicast support features, as defined in the XTP Protocol Definition Revision 3.4.

  4. Point-of-care testing system enabling 30 min detection of influenza genes.

    PubMed

    Abe, Tomoteru; Segawa, Yuji; Watanabe, Hidetoshi; Yotoriyama, Tasuku; Kai, Shinichi; Yasuda, Akio; Shimizu, Norio; Tojo, Naoko

    2011-03-21

    We developed a portable and easy-to-use nucleic acid amplification test (NAT) system for use in point-of-care testing (POCT). The system shows sensitivity that is sufficiently higher than that of the currently available rapid diagnostic kit and is comparable to that of real-time reverse transcription polymerase chain reaction (RT-PCR) for influenza testing. This journal is © The Royal Society of Chemistry 2011

  5. Integrating Point-of-Care Testing into a Community Emergency Department: A Mixed-Methods Evaluation.

    PubMed

    Pines, Jesse M; Zocchi, Mark S; Carter, Caitlin; Marriott, Charles Z; Bernard, Matthew; Warner, Leah H

    2018-05-13

    Point-of-care testing (POCT) is a commonly used technology that hastens the time to laboratory results in emergency departments (ED). We evaluated an ED-based POCT program on ED length of stay and time to care, coupled with qualitative interviews of local ED stakeholders. We conducted a mixed-methods study (2012-16) to examine the impact of point-of-care testing in a single, community ED. The quantiative analysis involved an observational before-after study comparing time to laboratory test result (POC troponin or POC chemistry) and ED length of stay after implementation of POCT, using a propensity-weighted interrupted time series analysis (ITSA). A complementary qualitative analysis involved five semi-structured interviews with staff using grounded theory on the benefits and challenges to ED POCT. A total of 47,399 ED visits were included in the study (24,705 in pre-intervention period and 22,694 in post-intervention). After POCT implementation, overall laboratory testing increased marginally from 61 to 62%. Central laboratory troponin and chemistry declined by >50% and was replaced by POCT. Prior to POCT implementation, time to troponin and chemistry had declined steadily due to other improvements in laboratory efficiency. After POCT implementation, there was an immediate 20 minute further decline (p<0.001) in both time to troponin and time to chemistry results using the propensity-weighted comparisons. However, the declining trend observed prior to POCT implementation did not continue at the same rate post implementation. Similarly, prior to POCT implementation, ED length of stay (LOS) declined due to other quality improvements. After POCT implementation, LOS continued declined at a similar rate. Because of this prior trend, the ITSA did not show a significant decline in LOS attributable to POCT. Common benefits of POCT perceived by staff in qualitative interviews included improved quality of care (64%), and reductions in time to test results (44%). Common

  6. Point-of-care blood gases, electrolytes, chemistries, hemoglobin, and hematocrit measurement in venous samples from pet rabbits.

    PubMed

    Selleri, Paolo; Di Girolamo, Nicola

    2014-01-01

    Point-of-care testing is an attractive option in rabbit medicine, because it permits rapid analysis of a panel of electrolytes, chemistries, blood gases, hemoglobin, and hematocrit, requiring only 65 μL of blood. The purpose of this study was to evaluate the performance of a portable clinical analyzer for measurement of pH, partial pressure of CO2, Na, chloride, potassium, blood urea nitrogen, glucose, hematocrit, and hemoglobin in healthy and diseased rabbits. Blood samples obtained from 30 pet rabbits were analyzed immediately after collection by the portable clinical analyzer (PCA) and immediately thereafter (time <20 sec) by a reference analyzer. Bland-Altman plots and Passing-Bablok regression analysis were used to compare the results. Limits of agreement were wide for all the variables studied, with the exception of pH. Most variables presented significant proportional and/or constant bias. The current study provides sufficient evidence that the PCA presents reliability for pH, although its low agreement with a reference analyzer for the other variables does not support their interchangeability. Limits of agreement provided for each variable allow researchers to evaluate if the PCA is reliable enough for their scope. To the authors' knowledge, the present is the first report evaluating a PCA in the rabbit.

  7. Cost-effectiveness of point-of-care testing for dehydration in the pediatric ED.

    PubMed

    Whitney, Rachel E; Santucci, Karen; Hsiao, Allen; Chen, Lei

    2016-08-01

    Acute gastroenteritis (AGE) and subsequent dehydration account for a large proportion of pediatric emergency department (PED) visits. Point-of-care (POC) testing has been used in conjunction with clinical assessment to determine the degree of dehydration. Despite the wide acceptance of POC testing, little formal cost-effective analysis of POC testing in the PED exists. We aim to examine the cost-effectiveness of using POC electrolyte testing vs traditional serum chemistry testing in the PED for children with AGE. This was a cost-effective analysis using data from a randomized control trial of children with AGE. A decision analysis model was constructed to calculate cost-savings from the point of view of the payer and the provider. We used parameters obtained from the trial, including cost of testing, admission rates, cost of admission, and length of stay. Sensitivity analyses were performed to evaluate the stability of our model. Using the data set of 225 subjects, POC testing results in a cost savings of $303.30 per patient compared with traditional serum testing from the point of the view of the payer. From the point-of-view of the provider, POC testing results in consistent mean savings of $36.32 ($8.29-$64.35) per patient. Sensitivity analyses demonstrated the stability of the model and consistent savings. This decision analysis provides evidence that POC testing in children with gastroenteritis-related moderate dehydration results in significant cost savings from the points of view of payers and providers compared to traditional serum chemistry testing. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Chemistry at the dirac point of graphene

    NASA Astrophysics Data System (ADS)

    Sarkar, Santanu

    device mobility. To this end, we find that the organometallic hexahapto metal complexation chemistry of graphene, in which the graphene pi-band constructively hybridizes with the vacant d-orbitals of transition metals, allows the fabrication of field effect devices which retain a high degree of the mobility with enhanced on-off ratio. In summary, we find that the singular electronic structure of graphene at the Dirac point governs the chemical reactivity of graphene and this chemistry will play a vital role in propelling graphene to assume its role as the next generation electronic material beyond silicon.

  9. Evaluation of three point-of-care healthcare databases: BMJ Point-of-Care, Clin-eguide and Nursing Reference Centre.

    PubMed

    Chan, Rachel; Stieda, Vivian

    2011-03-01

    Point of care resources make it easier for clinicians to find answers to questions that arise during a clinical encounter. In order to make informed purchase decisions in times of tight budgets, librarians need to have a better understanding of which resources will meet their patrons' clinical information needs.   The goal of this study was to assess the content, interface and usability of three point-of-care tools: BMJ Point-of-Care, Clin-eguide and Nursing Reference Centre.   A questionnaire designed to gather quantitative and qualitative data was created using Survey Monkey. The survey was distributed to healthcare practitioners in Alberta's two largest health regions, and the data were analysed for emergent themes.   The themes that arose--ease of use, validated content, relevancy to practice--generally echoed those stated in the literature. No one database fared significantly better, due to differing features, content and client preference.   Despite the limitations of the survey, the themes that emerged provide a springboard for future research on the efficacy of information resources used at the point of care, and the need for deeper analysis of these recent additions to the medical information market. © 2010 The authors. Health Information and Libraries Journal © 2010 Health Libraries Group.

  10. Point-of-care ultrasonography by pediatric emergency medicine physicians.

    PubMed

    Marin, Jennifer R; Lewiss, Resa E

    2015-04-01

    Emergency physicians have used point-of-care ultrasonography since the 1990 s. Pediatric emergency medicine physicians have more recently adopted this technology. Point-of-care ultrasonography is used for various scenarios, particularly the evaluation of soft tissue infections or blunt abdominal trauma and procedural guidance. To date, there are no published statements from national organizations specifically for pediatric emergency physicians describing the incorporation of point-of-care ultrasonography into their practice. This document outlines how pediatric emergency departments may establish a formal point-of-care ultrasonography program. This task includes appointing leaders with expertise in point-of-care ultrasonography, effectively training and credentialing physicians in the department, and providing ongoing quality assurance reviews. Copyright © 2015 by the American Academy of Pediatrics.

  11. Point-of-care and point-of-procedure optical imaging technologies for primary care and global health.

    PubMed

    Boppart, Stephen A; Richards-Kortum, Rebecca

    2014-09-10

    Leveraging advances in consumer electronics and wireless telecommunications, low-cost, portable optical imaging devices have the potential to improve screening and detection of disease at the point of care in primary health care settings in both low- and high-resource countries. Similarly, real-time optical imaging technologies can improve diagnosis and treatment at the point of procedure by circumventing the need for biopsy and analysis by expert pathologists, who are scarce in developing countries. Although many optical imaging technologies have been translated from bench to bedside, industry support is needed to commercialize and broadly disseminate these from the patient level to the population level to transform the standard of care. This review provides an overview of promising optical imaging technologies, the infrastructure needed to integrate them into widespread clinical use, and the challenges that must be addressed to harness the potential of these technologies to improve health care systems around the world. Copyright © 2014, American Association for the Advancement of Science.

  12. Point-of-care and point-of-procedure optical imaging technologies for primary care and global health

    PubMed Central

    Boppart, Stephen A.; Richards-Kortum, Rebecca

    2015-01-01

    Leveraging advances in consumer electronics and wireless telecommunications, low-cost, portable optical imaging devices have the potential to improve screening and detection of disease at the point of care in primary health care settings in both low- and high-resource countries. Similarly, real-time optical imaging technologies can improve diagnosis and treatment at the point of procedure by circumventing the need for biopsy and analysis by expert pathologists, who are scarce in developing countries. Although many optical imaging technologies have been translated from bench to bedside, industry support is needed to commercialize and broadly disseminate these from the patient level to the population level to transform the standard of care. This review provides an overview of promising optical imaging technologies, the infrastructure needed to integrate them into widespread clinical use, and the challenges that must be addressed to harness the potential of these technologies to improve health care systems around the world. PMID:25210062

  13. Fragment assignment in the cloud with eXpress-D

    PubMed Central

    2013-01-01

    Background Probabilistic assignment of ambiguously mapped fragments produced by high-throughput sequencing experiments has been demonstrated to greatly improve accuracy in the analysis of RNA-Seq and ChIP-Seq, and is an essential step in many other sequence census experiments. A maximum likelihood method using the expectation-maximization (EM) algorithm for optimization is commonly used to solve this problem. However, batch EM-based approaches do not scale well with the size of sequencing datasets, which have been increasing dramatically over the past few years. Thus, current approaches to fragment assignment rely on heuristics or approximations for tractability. Results We present an implementation of a distributed EM solution to the fragment assignment problem using Spark, a data analytics framework that can scale by leveraging compute clusters within datacenters–“the cloud”. We demonstrate that our implementation easily scales to billions of sequenced fragments, while providing the exact maximum likelihood assignment of ambiguous fragments. The accuracy of the method is shown to be an improvement over the most widely used tools available and can be run in a constant amount of time when cluster resources are scaled linearly with the amount of input data. Conclusions The cloud offers one solution for the difficulties faced in the analysis of massive high-thoughput sequencing data, which continue to grow rapidly. Researchers in bioinformatics must follow developments in distributed systems–such as new frameworks like Spark–for ways to port existing methods to the cloud and help them scale to the datasets of the future. Our software, eXpress-D, is freely available at: http://github.com/adarob/express-d. PMID:24314033

  14. Point-of-care lactate and creatinine analysis for sick obstetric patients at Queen Elizabeth Central Hospital in Blantyre, Malawi: A feasibility study.

    PubMed

    Glasmacher, S A; Bonongwe, P; Stones, W

    2016-03-01

    To achieve good outcomes in critically ill obstetric patients, it is necessary to identify organ dysfunction rapidly so that life-saving interventions can be appropriately commenced. However, timely access to clinical chemistry results is problematic, even in referral institutions, in the sub-Saharan African region. Reliable point-of-care tests licensed for clinical use are now available for lactate and creatinine. We aimed to assess whether implementation of point-of-care testing for lactate and creatinine is feasible in the obstetric unit at the Queen Elizabeth Central Hospital (QECH) in Blantyre, Malawi, by obtaining the opinions of clinical staff on the use of these tests in practice. During a two-month evaluation period nurse-midwives, medical interns, clinical officers, registrars, and consultants were given the opportunity to use StatStrip® and StatSensor® (Nova Biomedical, Waltham, USA) devices, for lactate and creatinine estimation, as part of their routine clinical practice in the obstetric unit. They were subsequently asked to complete a short questionnaire. Thirty-seven questionnaires were returned by participants: 22 from nurse-midwives and the remainder from clinicians. The mean satisfaction score for the devices was 7.6/10 amongst clinicians and 8.0/10 amongst nurse-midwives. The majority of participants stated that the obstetric high dependency unit (HDU) was the most suitable location for the devices. For lactate, 31 participants strongly agreed that testing should be continued and 24 strongly agreed that it would influence patient management. For creatinine, 29 strongly agreed that testing should be continued and 28 strongly agreed that it would influence their patient management. Twenty participants strongly agreed that they trust point-of-care devices. Point-of-care clinical chemistry testing was feasible, practical, and well received by staff, and was considered to have a useful role to play in the clinical care of sick obstetric patients at

  15. Clinical Chemistry of Patients With Ebola in Monrovia, Liberia

    PubMed Central

    de Wit, Emmie; Kramer, Shelby; Prescott, Joseph; Rosenke, Kyle; Falzarano, Darryl; Marzi, Andrea; Fischer, Robert J.; Safronetz, David; Hoenen, Thomas; Groseth, Allison; van Doremalen, Neeltje; Bushmaker, Trenton; McNally, Kristin L.; Feldmann, Friederike; Williamson, Brandi N.; Best, Sonja M.; Ebihara, Hideki; Damiani, Igor A. C.; Adamson, Brett; Zoon, Kathryn C.; Nyenswah, Tolbert G.; Bolay, Fatorma K.; Massaquoi, Moses; Sprecher, Armand; Feldmann, Heinz; Munster, Vincent J.

    2016-01-01

    The development of point-of-care clinical chemistry analyzers has enabled the implementation of these ancillary tests in field laboratories in resource-limited outbreak areas. The Eternal Love Winning Africa (ELWA) outbreak diagnostic laboratory, established in Monrovia, Liberia, to provide Ebola virus and Plasmodium spp. diagnostics during the Ebola epidemic, implemented clinical chemistry analyzers in December 2014. Clinical chemistry testing was performed for 68 patients in triage, including 12 patients infected with Ebola virus and 18 infected with Plasmodium spp. The main distinguishing feature in clinical chemistry of Ebola virus–infected patients was the elevation in alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, and γ-glutamyltransferase levels and the decrease in calcium. The implementation of clinical chemistry is probably most helpful when the medical supportive care implemented at the Ebola treatment unit allows for correction of biochemistry derangements and on-site clinical chemistry analyzers can be used to monitor electrolyte balance. PMID:27471319

  16. Accessing care summaries at point-of-care:Implementation of mobile devices for personal carers in aged care.

    PubMed

    Brimelow, Rachel E; Gibney, Annie; Meakin, Suzanne; Wollin, Judy A

    2017-04-01

    Continued development of mobile technology now allows access to information at the point-of-care. This study was conducted to evaluate the use of one such tool on a mobile device, from the carer perspective. Caregivers across 12 aged-care facilities were supplied mobile devices to access a Picture Care Plan (PCP), a specific tool designed around the role of the personal carer. An anonymous questionnaire was subsequently completed by 85 carers with questions relating to participants' experience. Perceived helpfulness of the PCP at the point-of-care was high (87%). A significant number of participants believed the use of the PCP increased resident safety and quality of care (76%). Practical components related to the carrying of the device, network speed and the requirement to maintain communication with senior members of staff to ascertain updates were also expressed by participants. Findings suggest that staff are receptive to adoption of mobile devices to access care directives at the point-of-care and that the technology is useful.

  17. Compact dry chemistry instruments.

    PubMed

    Terashima, K; Tatsumi, N

    1999-01-01

    Compact dry chemistry instruments are designed for use in point-of-care-testing (POCT). These instruments have a number of advantages, including light weight, compactness, ease of operation, and the ability to provide accurate results in a short time with a very small sample volume. On the other hand, reagent costs are high compared to liquid method. Moreover, differences in accuracy have been found between dry chemistry and the liquid method in external quality assessment scheme. This report examines reagent costs and shows how the total running costs associated with dry chemistry are actually lower than those associated with the liquid method. This report also describes methods for minimizing differences in accuracy between dry chemistry and the liquid method. Use of these measures is expected to increase the effectiveness of compact dry chemistry instruments in POCT applications.

  18. Clinical Chemistry of Patients With Ebola in Monrovia, Liberia.

    PubMed

    de Wit, Emmie; Kramer, Shelby; Prescott, Joseph; Rosenke, Kyle; Falzarano, Darryl; Marzi, Andrea; Fischer, Robert J; Safronetz, David; Hoenen, Thomas; Groseth, Allison; van Doremalen, Neeltje; Bushmaker, Trenton; McNally, Kristin L; Feldmann, Friederike; Williamson, Brandi N; Best, Sonja M; Ebihara, Hideki; Damiani, Igor A C; Adamson, Brett; Zoon, Kathryn C; Nyenswah, Tolbert G; Bolay, Fatorma K; Massaquoi, Moses; Sprecher, Armand; Feldmann, Heinz; Munster, Vincent J

    2016-10-15

    The development of point-of-care clinical chemistry analyzers has enabled the implementation of these ancillary tests in field laboratories in resource-limited outbreak areas. The Eternal Love Winning Africa (ELWA) outbreak diagnostic laboratory, established in Monrovia, Liberia, to provide Ebola virus and Plasmodium spp. diagnostics during the Ebola epidemic, implemented clinical chemistry analyzers in December 2014. Clinical chemistry testing was performed for 68 patients in triage, including 12 patients infected with Ebola virus and 18 infected with Plasmodium spp. The main distinguishing feature in clinical chemistry of Ebola virus-infected patients was the elevation in alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, and γ-glutamyltransferase levels and the decrease in calcium. The implementation of clinical chemistry is probably most helpful when the medical supportive care implemented at the Ebola treatment unit allows for correction of biochemistry derangements and on-site clinical chemistry analyzers can be used to monitor electrolyte balance. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  19. Smartphone chloridometer for point-of-care applications

    NASA Astrophysics Data System (ADS)

    Zhang, Chenji; Kim, Jimin P.; Creer, Michael; Yang, Jian; Liu, Zhiwen

    2017-08-01

    Chloride level in sweat is a major diagnostic criterion for cystic fibrosis (CF) and many other health conditions. In an effort to develop a low cost, point-of-care sweat diagnostics system for chloride concentration measurement, we demonstrated a smartphone-based chloridometer to measure sweat chloride by using our recently developed fluorescence chloride sensor. We characterized the performance of our device to validate its clinical potential. The study indicates that our smartphone-based chloridometer may potentially advance the point-of-care diagnostic system by reducing cost and improving diagnostic accuracy.

  20. Point-of-care oral-based diagnostics

    PubMed Central

    Hart, RW; Mauk, MG; Liu, C; Qiu, X; Thompson, JA; Chen, D; Malamud, D; Abrams, WR; Bau, HH

    2014-01-01

    Many of the target molecules that reside in blood are also present in oral fluids, albeit at lower concentrations. Oral fluids are, however, relatively easy and safe to collect without the need for specialized equipment and training. Thus, oral fluids provide convenient samples for medical diagnostics. Recent advances in lab-on-a-chip technologies have made minute, fully integrated diagnostic systems practical for an assortment of point-of-care tests. Such systems can perform either immunoassays or molecular diagnostics outside centralized laboratories within time periods ranging from minutes to an hour. The article briefly reviews recent advances in devices for point-of-care testing with a focus on work that has been carried out by the authors as part of a NIH program. PMID:21521419

  1. Point-of-care D-dimer testing in emergency departments.

    PubMed

    Marquardt, Udo; Apau, Daniel

    2015-09-01

    Overcrowding and prolonged patient stays in emergency departments (EDs) affect patients' experiences and outcomes, and increase healthcare costs. One way of addressing these problems is through using point-of-care blood tests, laboratory testing undertaken near patient locations with rapidly available results. D-dimer tests are used to exclude venous thromboembolism (VTE), a common presentation in EDs, in low-risk patients. However, data on the effects of point-of-care D-dimer testing in EDs and other urgent care settings are scarce. This article reports the results of a literature review that examined the benefits to patients of point-of-care D-dimer testing in terms of reduced turnaround times (time to results), and time to diagnosis, discharge or referral. It also considers the benefits to organisations in relation to reduced ED crowding and increased cost effectiveness. The review concludes that undertaking point-of-care D-dimer tests, combined with pre-test probability scores, can be a quick and safe way of ruling out VTE and improving patients' experience.

  2. Resident training in point-of-care testing.

    PubMed

    Campbell, Sheldon; Howanitz, Peter J

    2007-06-01

    Although central laboratory testing has been the norm for the last few decades and point-of-care testing (POCT) is considered an emerging area, physicians were performing POCT long before the existence of central laboratory testing. As medical directors of POCT programs, pathologists need the basic knowledge and skills associated with directing laboratory-based testing programs as well as additional knowledge and skills about testing at the point of care. Although the essential elements of quality testing are the same for laboratory-based and POCT, the enormous variety of settings, technologies, and workers involved present unique challenges.

  3. Point-of-Care Ultrasonography in Emergency and Critical Care Medicine.

    PubMed

    Chen, Leon; Malek, Tony

    To stabilize critically ill patients, emergency and critical care medicine providers often require rapid diagnosis and intervention. The demand for a safe, timely diagnostic device, alongside technological innovation, led to the advent of point-of-care ultrasonography (POCUS). POCUS allows the provider to gain invaluable clinical information with a high level of accuracy, leading to better clinical decision-making and improvements in patient safety. We have outlined the history of POCUS adaptation in emergency and critical care medicine and various clinical applications of POCUS described in literature.

  4. CMOS Cell Sensors for Point-of-Care Diagnostics

    PubMed Central

    Adiguzel, Yekbun; Kulah, Haluk

    2012-01-01

    The burden of health-care related services in a global era with continuously increasing population and inefficient dissipation of the resources requires effective solutions. From this perspective, point-of-care diagnostics is a demanded field in clinics. It is also necessary both for prompt diagnosis and for providing health services evenly throughout the population, including the rural districts. The requirements can only be fulfilled by technologies whose productivity has already been proven, such as complementary metal-oxide-semiconductors (CMOS). CMOS-based products can enable clinical tests in a fast, simple, safe, and reliable manner, with improved sensitivities. Portability due to diminished sensor dimensions and compactness of the test set-ups, along with low sample and power consumption, is another vital feature. CMOS-based sensors for cell studies have the potential to become essential counterparts of point-of-care diagnostics technologies. Hence, this review attempts to inform on the sensors fabricated with CMOS technology for point-of-care diagnostic studies, with a focus on CMOS image sensors and capacitance sensors for cell studies. PMID:23112587

  5. CMOS cell sensors for point-of-care diagnostics.

    PubMed

    Adiguzel, Yekbun; Kulah, Haluk

    2012-01-01

    The burden of health-care related services in a global era with continuously increasing population and inefficient dissipation of the resources requires effective solutions. From this perspective, point-of-care diagnostics is a demanded field in clinics. It is also necessary both for prompt diagnosis and for providing health services evenly throughout the population, including the rural districts. The requirements can only be fulfilled by technologies whose productivity has already been proven, such as complementary metal-oxide-semiconductors (CMOS). CMOS-based products can enable clinical tests in a fast, simple, safe, and reliable manner, with improved sensitivities. Portability due to diminished sensor dimensions and compactness of the test set-ups, along with low sample and power consumption, is another vital feature. CMOS-based sensors for cell studies have the potential to become essential counterparts of point-of-care diagnostics technologies. Hence, this review attempts to inform on the sensors fabricated with CMOS technology for point-of-care diagnostic studies, with a focus on CMOS image sensors and capacitance sensors for cell studies.

  6. Point-of-care ultrasonography by pediatric emergency physicians. Policy statement.

    PubMed

    Marin, Jennifer R; Lewiss, Resa E

    2015-04-01

    Point-of-care ultrasonography is increasingly being used to facilitate accurate and timely diagnoses and to guide procedures. It is important for pediatric emergency physicians caring for patients in the emergency department to receive adequate and continued point-of-care ultrasonography training for those indications used in their practice setting. Emergency departments should have credentialing and quality assurance programs. Pediatric emergency medicine fellowships should provide appropriate training to physician trainees. Hospitals should provide privileges to physicians who demonstrate competency in point-of-care ultrasonography. Ongoing research will provide the necessary measures to define the optimal training and competency assessment standards. Requirements for credentialing and hospital privileges will vary and will be specific to individual departments and hospitals. As more physicians are trained and more research is completed, there should be one national standard for credentialing and privileging in point-of-care ultrasonography for pediatric emergency physicians.

  7. Internet Point of Care Learning at a Community Hospital

    ERIC Educational Resources Information Center

    Sinusas, Keith

    2009-01-01

    Introduction: Internet point of care (PoC) learning is a relatively new method for obtaining continuing medical education credits. Few data are available to describe physician utilization of this CME activity. Methods: We describe the Internet point of care system we developed at a medium-sized community hospital and report on its first year of…

  8. Optimizing point-of-care testing in clinical systems management.

    PubMed

    Kost, G J

    1998-01-01

    The goal of improving medical and economic outcomes calls for leadership based on fundamental principles. The manager of clinical systems works collaboratively within the acute care center to optimize point-of-care testing through systematic approaches such as integrative strategies, algorithms, and performance maps. These approaches are effective and efficacious for critically ill patients. Optimizing point-of-care testing throughout the entire health-care system is inherently more difficult. There is potential to achieve high-quality testing, integrated disease management, and equitable health-care delivery. Despite rapid change and economic uncertainty, a macro-strategic, information-integrated, feedback-systems, outcomes-oriented approach is timely, challenging, effective, and uplifting to the creative human spirit.

  9. Electrical Chips for Biological Point-of-Care Detection.

    PubMed

    Reddy, Bobby; Salm, Eric; Bashir, Rashid

    2016-07-11

    As the future of health care diagnostics moves toward more portable and personalized techniques, there is immense potential to harness the power of electrical signals for biological sensing and diagnostic applications at the point of care. Electrical biochips can be used to both manipulate and sense biological entities, as they can have several inherent advantages, including on-chip sample preparation, label-free detection, reduced cost and complexity, decreased sample volumes, increased portability, and large-scale multiplexing. The advantages of fully integrated electrical biochip platforms are particularly attractive for point-of-care systems. This review summarizes these electrical lab-on-a-chip technologies and highlights opportunities to accelerate the transition from academic publications to commercial success.

  10. A point of view: why point-of-care places are not free marketplaces.

    PubMed

    Rambur, B; Mooney, M M

    1998-01-01

    Current wisdom holds that health care is a business and "as such must abide by market principles." Most nurses are not well enough versed in economic theories to credibly critique health care delivery decisions based on economic theories. The relationship of market principles to health care realities is described in basic terms to encourage nurses to "optimize patient care and influence health care policy." Physicians, who control all access points to the health care system, have enjoyed a 40-year market dominance that is "rapidly being replaced by insurance companies and for-profit investors." Providers' decisions to treat or not to treat are strongly influenced by whether the patient is in a fee-for-service or capitated payment environment.

  11. Study protocol: identifying and delivering point-of-care information to improve care coordination.

    PubMed

    Hysong, Sylvia J; Che, Xinxuan; Weaver, Sallie J; Petersen, Laura A

    2015-10-19

    The need for deliberately coordinated care is noted by many national-level organizations. The Department of Veterans Affairs (VA) recently transitioned primary care clinics nationwide into Patient Aligned Care Teams (PACTs) to provide more accessible, coordinated, comprehensive, and patient-centered care. To better serve this purpose, PACTs must be able to successfully sequence and route interdependent tasks to appropriate team members while also maintaining collective situational awareness (coordination). Although conceptual frameworks of care coordination exist, few explicitly articulate core behavioral markers of coordination or the related information needs of team members attempting to synchronize complex care processes across time for a shared patient population. Given this gap, we partnered with a group of frontline primary care personnel at ambulatory care sites to identify the specific information needs of PACT members that will enable them to coordinate their efforts to provide effective, coordinated care. The study has three objectives: (1) development of measurable, prioritized point-of-care criteria for effective PACT coordination; (2) identifying the specific information needed at the point of care to optimize coordination; and (3) assessing the effect of adopting the aforementioned coordination standards on PACT clinicians' coordination behaviors. The study consists of three phases. In phase 1, we will employ the Productivity Measurement and Enhancement System (ProMES), a structured approach to performance measure creation from industrial/organizational psychology, to develop coordination measures with a design team of 6-10 primary care personnel; in phase 2, we will conduct focus groups with the phase 1 design team to identify point-of-care information needs. Phase 3 is a two-arm field experiment (n PACT = 28/arm); intervention arm PACTs will receive monthly feedback reports using the measures developed in phase 1 and attend brief monthly

  12. Point-of-care diagnostics: market trends and growth drivers.

    PubMed

    Rajan, Aruna; Glorikian, Harry

    2009-01-01

    There is a significant demand for in vitro diagnostic (IVD) testing to move closer to the patient point-of-care diagnostics [POC]), whether in the hospital, physician's office, rapid clinic or the home, effectively cutting time to results and helping patients make better informed decisions about their health. To analyze the point-of-care market and its trends and growth drivers. In 2007, POC made up 30% of the IVD market and is expected to grow at 9% a year. Although the overall POC market is expected to grow steadily, infectious POC is now the most attractive segment. Availability of rapid random access molecular diagnostic system for critical care infectious diseases such as MRSA and sepsis in the near future is likely to be a significant driver of infectious POC post 2012. Owing to the extraordinary increase in the cost of care, healthcare delivery is moving to increasingly decentralized settings such as rapid clinics and the home, driven by point-of-care diagnostics that provide accurate and directional results. We are evolving from the analog testing world to the digital testing world, where diagnosis is exact and therapy can be administered and be predictably effective.

  13. Electrical chips for biological point-of-care detection

    USDA-ARS?s Scientific Manuscript database

    As the future of health care diagnostics moves toward more portable and personalized techniques, there is immense potential to harness the power of electrical signals for biological sensing and diagnostic applications at the point of care. Electrical biochips can be used to both manipulate and sense...

  14. [Microbiological point of care tests].

    PubMed

    Book, Malte; Lehmann, Lutz Eric; Zhang, Xianghong; Stüber, Frank

    2010-11-01

    It is well known that the early initiation of a specific antiinfective therapy is crucial to reduce the mortality in severe infection. Procedures culturing pathogens are the diagnostic gold standard in such diseases. However, these methods yield results earliest between 24 to 48 hours. Therefore, severe infections such as sepsis need to be treated with an empirical antimicrobial therapy, which is ineffective in an unknown fraction of these patients. Today's microbiological point of care tests are pathogen specific and therefore not appropriate for an infection with a variety of possible pathogens. Molecular nucleic acid diagnostics such as polymerase chain reaction (PCR) allow the identification of pathogens and resistances. These methods are used routinely to speed up the analysis of positive blood cultures. The newest PCR based system allows the identification of the 25 most frequent sepsis pathogens by PCR in parallel without previous culture in less than 6 hours. Thereby, these systems might shorten the time of possibly insufficient antiinfective therapy. However, these extensive tools are not suitable as point of care diagnostics. Miniaturization and automating of the nucleic acid based method is pending, as well as an increase of detectable pathogens and resistance genes by these methods. It is assumed that molecular PCR techniques will have an increasing impact on microbiological diagnostics in the future. © Georg Thieme Verlag Stuttgart · New York.

  15. Point-of-Care Ultrasound: A Trend in Health Care.

    PubMed

    Buerger, Anita M; Clark, Kevin R

    2017-11-01

    To discuss the current and growing use of point-of-care (POC) ultrasound in the management and care of patients. Several electronic research databases were searched to find articles that emphasized the use of POC ultrasound by health care providers who manage and treat critically ill or injured patients. Thirty-five relevant peer-reviewed journal articles were selected for this literature review. Common themes identified in the literature included the use of POC ultrasound in emergency medicine, military medicine, and remote care; comparison of POC ultrasound to other medical imaging modalities; investigation of the education and training required for nonimaging health care professionals who perform POC ultrasound in their practices; and discussion of the financial implications and limitations of POC ultrasound. POC ultrasound provides clinicians with real-time information to better manage and treat critically ill or injured patients in emergency medicine, military medicine, and remote care. In addition to providing immediate bedside diagnostic information, use of POC ultrasound has increased because of concerns regarding radiation protection. Finally, the expansion of POC ultrasound to other specialty areas requires nonimaging health care professionals to perform bedside ultrasound examinations and interpret the resulting images. Because POC ultrasound is user-dependent, adequate training is essential for all who perform and interpret the examinations. Research involving POC ultrasound will continue as innovations and confidence in ultrasound applications advance. Future research should continue to examine the broad use of POC ultrasound in patient care and management. ©2017 American Society of Radiologic Technologists.

  16. Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis

    PubMed Central

    2014-01-01

    Background The increasing prevalence of diabetes in Ontario means that there will be growing demand for hemoglobin A1c (HbA1c) testing to monitor glycemic control for the management of this chronic disease. Testing HbA1c where patients receive their diabetes care may improve system efficiency if the results from point-of-care HbA1c testing are comparable to those from laboratory HbA1c measurements. Objectives To review the correlation between point-of-care HbA1c testing and laboratory HbA1c measurement in patients with diabetes in clinical settings. Data Sources The literature search included studies published between January 2003 and June 2013. Search terms included glycohemoglobin, hemoglobin A1c, point of care, and diabetes. Review Methods Studies were included if participants had diabetes; if they compared point-of-care HbA1c devices (licensed by Health Canada and available in Canada) with laboratory HbA1c measurement (reference method); if they performed point-of-care HbA1c testing using capillary blood samples (finger pricks) and laboratory HbA1c measurement using venous blood samples within 7 days; and if they reported a correlation coefficient between point-of-care HbA1c and laboratory HbA1c results. Results Three point-of-care HbA1c devices were reviewed in this analysis: Bayer's A1cNow+, Bio-Rad's In2it, and Siemens’ DCA Vantage. Five observational studies met the inclusion criteria. The pooled results showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement (correlation coefficient, 0.967; 95% confidence interval, 0.960–0.973). Limitations Outcomes were limited to the correlation coefficient, as this was a commonly reported measure of analytical performance in the literature. Results should be interpreted with caution due to risk of bias related to selection of participants, reference standards, and the multiple steps involved in POC HbA1c testing. Conclusions Moderate quality evidence showed a positive

  17. ClinicalKey: a point-of-care search engine.

    PubMed

    Vardell, Emily

    2013-01-01

    ClinicalKey is a new point-of-care resource for health care professionals. Through controlled vocabulary, ClinicalKey offers a cross section of resources on diseases and procedures, from journals to e-books and practice guidelines to patient education. A sample search was conducted to demonstrate the features of the database, and a comparison with similar tools is presented.

  18. Anticorrelation between Surface and Subsurface Point Defects and the Impact on the Redox Chemistry of TiO2(110)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, Yeohoon; Du, Yingge; Garcia, Juan C.

    2015-02-02

    Using combination of STM, DFT and SIMS, we explored the interplay and relative impact of surface vs. subsurface defects on the surface chemistry of rutile TiO2. STM results show that surface O vacancies (VO’s) are virtually absent in the vicinity of positively-charged subsurface point-defects. This observation is consistent with DFT calculations of impact of subsurface defect proximity on VO formation energy. To monitor the influence of such lateral anticorrelation on surface redox chemistry, a test reaction of the dissociative adsorption of O2 is employed, which is observed to be suppressed around them. DFT results attribute this to a perceived absencemore » of the intrinsic (Ti) (and likely extrinsic) interstitials in the nearest subsurface layer beneath “inhibited” areas. We also postulate that the entire nearest subsurface region could be voided of any charged point-defects, whereas prevalent VO’s are largely responsible for mediation of the redox chemistry at reduced TiO2(110) surface.« less

  19. Enhancing crisis standards of care using innovative point-of-care testing.

    PubMed

    Kost, Gerald J; Sakaguchi, Ann; Curtis, Corbin; Tran, Nam K; Katip, Pratheep; Louie, Richard F

    2011-01-01

    To identify strategies with tactics that enable point-of-care (POC) testing (medical testing at or near the site of care) to effectively improve outcomes in emergencies, disasters, and public health crises, especially where community infrastructure is compromised. Logic model-critical path-feedback identified needs for improving practices. Reverse stress analysis showed POC should be integrated, responders should be properly trained, and devices should be staged in small-world networks (SWNs). First responder POC resources were summarized, test clusters were strategized, assay environmental vulnerabilities were assessed, and tactics useful for SWNs, alternate care facilities, shelters, point-of-distribution centers, and community hospitals were designed. PARTICIPANTS AND ENVIRONMENT: Emergency-disaster needs assessment survey respondents and Center experience. Important tactics are as follows: a) develop training/education courses and '"just-in-time" on-line web resources to ensure the competency of POC coordinators and high-quality testing performance; b) protect equipment from environmental extremes by sealing reagents, by controlling temperature and humidity to which they are exposed, and by establishing near-patient testing in defined environments that operate within current Food and Drug Administration licensing claims (illustrated with human immunodeficiency virus-1/2 tests); c) position testing in defined sites within SWNs and other environments; d) harden POC devices and reagents to withstand wider ranges of environmental extremes in field applications; e) promote new POC technologies for pathogen detection and other assays, per needs assessment results; and f) select tests according to mission objectives and value propositions. Careful implementation of POC testing will facilitate evidence-based triage, diagnosis, treatment, and monitoring of victims and patients, while advancing standards of care in emergencies and disasters, as well as public health

  20. ENHANCING CRISIS STANDARDS OF CARE USING INNOVATIVE POINT-OF-CARE TESTING

    PubMed Central

    Kost, Gerald J.; Sakaguchi, Ann; Curtis, Corbin; Tran, Nam K.; Katip, Pratheep; Louie, Richard F.

    2011-01-01

    Objective To identify strategies with tactics that enable point-of-care (POC) testing (medical testing at or near the site of care) to improve outcomes effectively in emergencies, disasters, and public health crises, especially where community infrastructure is compromised. Design Logic model-critical path-feedback identified needs for improving practices. Reverse stress analysis showed POC should be integrated, responders properly trained, and devices staged in small-world networks (SWNs). We summarize first responder POC resources, strategize test clusters, address assay environmental vulnerabilities, and design tactics useful for SWNs, alternate care facilities, shelters, point-of-distribution centers, and community hospitals. Participants and Environment Emergency-disaster needs assessment survey respondents and Center experience. Outcomes Important tactics are: a) develop training/education courses and “just-in-time” on-line web resources to assure the competency of POC coordinators and high quality testing performance; b) protect equipment from environmental extremes by sealing reagents, controlling temperature and humidity to which they are exposed, and establishing near-patient testing in defined environments that operate within current FDA licensing claims (illustrated with HIV-1/2 tests); c) position testing in defined sites within SWNs and other environments; d) harden POC devices and reagents to withstand wider ranges of environmental extremes in field applications; e) promote new POC technologies for pathogen detection and other assays, per needs assessment results; and f) select tests according to mission objectives and value propositions. Conclusions Careful implementation of POC testing will facilitate evidence-based triage, diagnosis, treatment, and monitoring of victims and patients, while advancing standards of care in emergencies and disasters, as well as public health crises. PMID:22338316

  1. Creating a Web-accessible, point-of-care, team-based information system (PointTIS): the librarian as publisher.

    PubMed

    Burrows, S C; Moore, K M; Lemkau, H L

    2001-04-01

    The Internet has created new opportunities for librarians to develop information systems that are readily accessible at the point of care. This paper describes the multiyear process used to justify, fund, design, develop, promote, and evaluate a rehabilitation prototype of a point-of-care, team-based information system (PoinTIS) and train health care providers to use this prototype for their spinal cord injury and traumatic brain injury patient care and education activities. PoinTIS is a successful model for librarians in the twenty-first century to serve as publishers of information created or used by their parent organizations and to respond to the opportunities for information dissemination provided by recent technological advances.

  2. Point-of-Care Technologies for Precision Cardiovascular Care and Clinical Research

    PubMed Central

    King, Kevin; Grazette, Luanda P.; Paltoo, Dina N.; McDevitt, John T.; Sia, Samuel K.; Barrett, Paddy M.; Apple, Fred S.; Gurbel, Paul A.; Weissleder, Ralph; Leeds, Hilary; Iturriaga, Erin J.; Rao, Anupama; Adhikari, Bishow; Desvigne-Nickens, Patrice; Galis, Zorina S.; Libby, Peter

    2016-01-01

    Point-of-care technologies (POC or POCT) are enabling innovative cardiovascular diagnostics that promise to improve patient care across diverse clinical settings. The National Heart, Lung, and Blood Institute convened a working group to discuss POCT in cardiovascular medicine. The multidisciplinary working group, which included clinicians, scientists, engineers, device manufacturers, regulatory officials, and program staff, reviewed the state of the POCT field; discussed opportunities for POCT to improve cardiovascular care, realize the promise of precision medicine, and advance the clinical research enterprise; and identified barriers facing translation and integration of POCT with existing clinical systems. A POCT development roadmap emerged to guide multidisciplinary teams of biomarker scientists, technologists, health care providers, and clinical trialists as they: 1) formulate needs assessments; 2) define device design specifications; 3) develop component technologies and integrated systems; 4) perform iterative pilot testing; and 5) conduct rigorous prospective clinical testing to ensure that POCT solutions have substantial effects on cardiovascular care. PMID:26977455

  3. Validation of a hand-held point of care device for lactate in adult and pediatric patients using traditional and locally-smoothed median and maximum absolute difference curves.

    PubMed

    Colon-Franco, Jessica Marie; Lo, Stanley F; Tarima, Sergey S; Gourlay, David; Drendel, Amy L; Brook Lerner, E

    2017-05-01

    Lactate is commonly used in septic patients and is a viable biomarker for trauma patients. Its pre-hospital use could assist triaging and managing patients with these conditions. We evaluated the analytical performance of the point-of-care (POC) StatStrip Xpress Lactate Meter (Nova Biomedical) and compared it to the ABL 800 (Radiometer). We measured lactate in 250 adult and 250 pediatric whole blood samples in 2 laboratories. The performance of the POC meter was assessed by traditional linear regression and Bland-Altman plots, and locally-smoothed (LS) median absolute difference and maximum absolute difference (MAD and MaxAD) curves. The StatStrip was linear with acceptable reproducibility at clinically relevant concentrations. Correlation with the ABL800 showed a negative bias for both populations with slope, bias ±SD (% bias) of 0.78, -0.4±0.7 (-14.5%) in children and 0.80-0.3±0.6 (-13.3%) in adults. The proportional bias appeared more significant at concentrations >4mmol/l (36.0mg/dl). The StatStrip misclassified 7.6 and 8.8% pediatric and adult samples, respectively, to lower risk categories defined using guidelines driven cut-offs. The LS MAD curves identified one breakout, concentration where the LS MAD exceeds the total allowable error limit of 0.3mmol/l (2.7mg/dl), at lactate concentrations of 3.8 and 3.2mmol/l (34.2 and 28.8mg/dl) in the pediatric and adult curves, respectively. Breakthroughs, points at which the LS MaxAD curve exceeds the 95th percentile of MaxADs, occur at concentrations above 7.5mmol/l (67.6mg/dl) for both populations where the performance of the POC meter became erratic. We concluded that if serial lactate measurements are performed, the same method should be used for baseline and follow up measurements. The LS MAD and LS MaxAD curves allowed visual and quantitative mapping of the performance of the lactate POC meter over the range of concentrations measured. This approach seems useful for the identification of points at which the

  4. Nursing Reference Center: a point-of-care resource.

    PubMed

    Vardell, Emily; Paulaitis, Gediminas Geddy

    2012-01-01

    Nursing Reference Center is a point-of-care resource designed for the practicing nurse, as well as nursing administrators, nursing faculty, and librarians. Users can search across multiple resources, including topical Quick Lessons, evidence-based care sheets, patient education materials, practice guidelines, and more. Additional features include continuing education modules, e-books, and a new iPhone application. A sample search and comparison with similar databases were conducted.

  5. The Fundamentals of Care Framework as a Point-of-Care Nursing Theory.

    PubMed

    Kitson, Alison L

    Nursing theories have attempted to shape the everyday practice of clinical nurses and patient care. However, many theories-because of their level of abstraction and distance from everyday caring activity-have failed to help nurses undertake the routine practical aspects of nursing care in a theoretically informed way. The purpose of the paper is to present a point-of-care theoretical framework, called the fundamentals of care (FOC) framework, which explains, guides, and potentially predicts the quality of care nurses provide to patients, their carers, and family members. The theoretical framework is presented: person-centered fundamental care (PCFC)-the outcome for the patient and the nurse and the goal of the FOC framework are achieved through the active management of the practice process, which involves the nurse and the patient working together to integrate three core dimensions: establishing the nurse-patient relationship, integrating the FOC into the patient's care plan, and ensuring that the setting or context where care is transacted and coordinated is conducive to achieving PCFC outcomes. Each dimension has multiple elements and subelements, which require unique assessment for each nurse-patient encounter. The FOC framework is presented along with two scenarios to demonstrate its usefulness. The dimensions, elements, and subelements are described, and next steps in the development are articulated.

  6. [Point-of-care Coagulation Testing in Neurosurgery].

    PubMed

    Adam, Elisabeth Hannah; Füllenbach, Christoph; Lindau, Simone; Konczalla, Jürgen

    2018-06-01

    Disorders of the coagulation system can seriously impact the clinical course and outcome of neurosurgical patients. Due to the anatomical location of the central nervous system within the closed skull, bleeding complications can lead to devastating consequences such as an increase in intracranial pressure or enlargement of intracranial hematoma. Point-of-care (POC) devices for the testing of haemostatic parameters have been implemented in various fields of medicine. Major advantages of these devices are that results are available quickly and that analysis can be performed at the bedside, directly affecting patient management. POC devices allow identification of increased bleeding tendencies and therefore may enable an assessment of hemorrhagic risks in neurosurgical patients. Although data regarding the use of POC testing in neurosurgical patients are limited, they suggest that coagulation testing and hemostatic therapy using POC devices might have beneficial effects in this patient population. This article provides an overview of the application of point-of-care coagulation testing in clinical practice in neurosurgical patients. Georg Thieme Verlag KG Stuttgart · New York.

  7. Does point-of-care functional echocardiography enhance cardiovascular care in the NICU?

    PubMed

    Sehgal, A; McNamara, P J

    2008-11-01

    Although the last two decades have seen major advances in the care of sick, extremely premature newborns, the approach to cardiovascular assessment and monitoring remains suboptimal owing to an overreliance on poorly predictive clinical markers such as heart rate or capillary refill time. Point-of-care functional echocardiography (PCFecho) enables real-time evaluation of cardiac performance and systemic hemodynamics to characterize acute physiology, identify the exact nature of cardiovascular compromise and guide therapeutic decisions. In this article, we will review four clinical scenarios where bedside functional cardiac imaging enabled delineation of the real clinical problem and refinement of the therapeutic care plan with direct patient benefits.

  8. ClinicalKey 2.0: Upgrades in a Point-of-Care Search Engine.

    PubMed

    Huslig, Mary Ann; Vardell, Emily

    2015-01-01

    ClinicalKey 2.0, launched September 23, 2014, offers a mobile-friendly design with a search history feature for targeting point-of-care resources for health care professionals. Browsing is improved with searchable, filterable listings of sources highlighting new resources. ClinicalKey 2.0 improvements include more than 1,400 new Topic Pages for quick access to point-of-care content. A sample search details some of the upgrades and content options.

  9. Point-of-care diagnostics: will the hurdles be overcome this time?

    PubMed

    Huckle, David

    2006-07-01

    Point-of-care diagnostics have been proposed as the latest development in clinical diagnostics several times in the last 30 years; however, they have not yet fully developed into a business sector to match the projections. This perspective examines the reasons for past failures and the failure of technology to meet user needs. Advances have taken place in the last few years that effectively remove technology as a barrier to the development of point-of-care testing. Even regulatory issues regarding how products are developed and claims supported have been absorbed, understood and now accepted. The emphasis here is on the possible favorable aspects that are novel this time around. These changes have arisen as a result of the situation with global healthcare economics and the pressure from patients to be treated more like customers. The final hurdles relate to the conflict between diagnosis with the patient present and treated as soon as the point-of-care result is available and the entrenched positions of the central laboratory, the suppliers and their established distribution chains, and the way in which healthcare budgets are allocated. The ultimate hurdle that encapsulates all of these issues is reimbursement, which is the final barrier to a significant point-of-care diagnostics market--without reimbursement there will be no market.

  10. Operationalizing Semantic Medline for meeting the information needs at point of care.

    PubMed

    Rastegar-Mojarad, Majid; Li, Dingcheng; Liu, Hongfang

    2015-01-01

    Scientific literature is one of the popular resources for providing decision support at point of care. It is highly desirable to bring the most relevant literature to support the evidence-based clinical decision making process. Motivated by the recent advance in semantically enhanced information retrieval, we have developed a system, which aims to bring semantically enriched literature, Semantic Medline, to meet the information needs at point of care. This study reports our work towards operationalizing the system for real time use. We demonstrate that the migration of a relational database implementation to a NoSQL (Not only SQL) implementation significantly improves the performance and makes the use of Semantic Medline at point of care decision support possible.

  11. Operationalizing Semantic Medline for meeting the information needs at point of care

    PubMed Central

    Rastegar-Mojarad, Majid; Li, Dingcheng; Liu, Hongfang

    2015-01-01

    Scientific literature is one of the popular resources for providing decision support at point of care. It is highly desirable to bring the most relevant literature to support the evidence-based clinical decision making process. Motivated by the recent advance in semantically enhanced information retrieval, we have developed a system, which aims to bring semantically enriched literature, Semantic Medline, to meet the information needs at point of care. This study reports our work towards operationalizing the system for real time use. We demonstrate that the migration of a relational database implementation to a NoSQL (Not only SQL) implementation significantly improves the performance and makes the use of Semantic Medline at point of care decision support possible. PMID:26306259

  12. Matching point-of care devices to clinicians for positive outcomes.

    PubMed

    Utterback, Karen; Waldo, Billie H

    2005-07-01

    Home care clinicians' use of point-of-care (POC) technology has increased 63% in the past 5 years. Although there are more POC system choices, matching the right device to each clinician's role is a challenge. This article clarifies the uses of laptop or notebook computer, personal digital assistants (PDAs), telephony, or automated telehealth, suggesting ways these technologies can result in clinical efficiencies, care coordination, and regulatory compliance.

  13. Prospective Chemistry Teachers' Misconceptions about Colligative Properties: Boiling Point Elevation and Freezing Point Depression

    ERIC Educational Resources Information Center

    Pinarbasi, Tacettin; Sozbilir, Mustafa; Canpolat, Nurtac

    2009-01-01

    This study aimed at identifying prospective chemistry teachers' misconceptions of colligative properties. In order to fulfill this aim, a diagnostic test composed of four open-ended questions was used. The test was administered to seventy-eight prospective chemistry teachers just before qualifying to teaching in secondary schools. Nine different…

  14. Point of View: Teaching Chemistry for the Twenty-Second Century

    ERIC Educational Resources Information Center

    Wright, Steven M.

    2013-01-01

    In this article, the author reflects on chemistry teaching in the next century. He questions--Was anything he taught in his fundamental chemistry course of value? And, how will our current understanding of the molecular world change during his students' lifetimes? It reminded him of a pseudo-quote he remembered from his own university…

  15. Point-of-Care Testing: General Aspects.

    PubMed

    Ferreira, Carlos E S; Guerra, Joao C C; Slhessarenko, Natasha; Scartezini, Marileia; Franca, Carolina N; Colombini, Marjorie P; Berlitz, Fernando; Machado, Antonia M O; Campana, Gustavo A; Faulhaber, Adriana C L; Galoro, Cesar A; Dias, Claudia M; Shcolnik, Wilson; Martino, Marines D V; Cesar, Katia R; Sumita, Nairo M; Mendes, Maria E; Faulhaber, Marcelo H W; Pinho, Joao R R; Barbosa, Ismar V; Batista, Marcelo C; Khawali, Cristina; Pariz, Vitor M; Andriolo, Adagmar

    2018-01-01

    Point-of-Care Testing (POCT) has been highlighted in the health care sector in recent decades. On the other hand, due to its low demand, POCT is at a disadvantage compared to conventional equipment, since its cost is inversely proportional to the volume of use. In addition, for the implementation of POCT to succeed, it is essential to rely on the work of a multidisciplinary team. The awareness of health professionals of the importance of each step is perhaps the critical success factor. The trend towards the continuous advancement of the use of POCT and the great potential of its contributions reinforce the need to implement quality management tools, including performance indicators, to ensure their results. This review presents some advantages and disadvantages concerning POCT and the real need to use it. A worldwide call for the availability of easy-to-use health technologies that are increasingly closer to the final user is one of the main reasons for this focus.

  16. Point-of-care blood eosinophil count in a severe asthma clinic setting.

    PubMed

    Heffler, Enrico; Terranova, Giovanni; Chessari, Carlo; Frazzetto, Valentina; Crimi, Claudia; Fichera, Silvia; Picardi, Giuseppe; Nicolosi, Giuliana; Porto, Morena; Intravaia, Rossella; Crimi, Nunzio

    2017-07-01

    One of the main severe asthma phenotypes is severe eosinophilic or eosinophilic refractory asthma for which novel biologic agents are emerging as therapeutic options. In this context, blood eosinophil counts are one of the most reliable biomarkers. To evaluate the performance of a point-of-care peripheral blood counter in a patients with severe asthma. The blood eosinophil counts of 76 patients with severe asthma were evaluated by point-of-care and standard analyzers. A significant correlation between blood eosinophils assessed by the 2 devices was found (R 2  = 0.854, P < .001); similar correlations were found also for white blood cells, neutrophils, and lymphocytes. The point-of-care device had the ability to predict blood eosinophil cutoffs used to select patients for biologic treatments for severe eosinophilic asthma and the ELEN index, a composite score useful to predict sputum eosinophilia. The results of our study contribute to the validation of a point-of-care device to assess blood eosinophils and open the possibility of using this device for the management of severe asthma management. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  17. Chemistry Notes.

    ERIC Educational Resources Information Center

    School Science Review, 1983

    1983-01-01

    Presents background information, laboratory procedures, classroom materials/activities, and chemistry experiments. Topics include sublimation, electronegativity, electrolysis, experimental aspects of strontianite, halide test, evaluation of present and future computer programs in chemistry, formula building, care of glass/saturated calomel…

  18. Handheld, point-of-care laser speckle imaging

    PubMed Central

    Farraro, Ryan; Fathi, Omid; Choi, Bernard

    2016-01-01

    Abstract. Laser speckle imaging (LSI) enables measurement of relative changes in blood flow in biological tissues. We postulate that a point-of-care form factor will lower barriers to routine clinical use of LSI. Here, we describe a first-generation handheld LSI device based on a tablet computer. The coefficient of variation of speckle contrast was <2% after averaging imaging data collected over an acquisition period of 5.3 s. With a single, experienced user, handheld motion artifacts had a negligible effect on data collection. With operation by multiple users, we did not identify any significant difference (p>0.05) between the measured speckle contrast values using either a handheld or mounted configuration. In vivo data collected during occlusion experiments demonstrate that a handheld LSI is capable of both quantitative and qualitative assessment of changes in blood flow. Finally, as a practical application of handheld LSI, we collected data from a 53-day-old neonate with confirmed compromised blood flow in the hand. We readily identified with LSI a region of diminished blood flow in the thumb of the affected hand. Our data collectively suggest that handheld LSI is a promising technique to enable clinicians to obtain point-of-care measurements of blood flow. PMID:27579578

  19. Handheld, point-of-care laser speckle imaging

    NASA Astrophysics Data System (ADS)

    Farraro, Ryan; Fathi, Omid; Choi, Bernard

    2016-09-01

    Laser speckle imaging (LSI) enables measurement of relative changes in blood flow in biological tissues. We postulate that a point-of-care form factor will lower barriers to routine clinical use of LSI. Here, we describe a first-generation handheld LSI device based on a tablet computer. The coefficient of variation of speckle contrast was <2% after averaging imaging data collected over an acquisition period of 5.3 s. With a single, experienced user, handheld motion artifacts had a negligible effect on data collection. With operation by multiple users, we did not identify any significant difference (p>0.05) between the measured speckle contrast values using either a handheld or mounted configuration. In vivo data collected during occlusion experiments demonstrate that a handheld LSI is capable of both quantitative and qualitative assessment of changes in blood flow. Finally, as a practical application of handheld LSI, we collected data from a 53-day-old neonate with confirmed compromised blood flow in the hand. We readily identified with LSI a region of diminished blood flow in the thumb of the affected hand. Our data collectively suggest that handheld LSI is a promising technique to enable clinicians to obtain point-of-care measurements of blood flow.

  20. Guidelines for point-of-care testing: haematology.

    PubMed

    Briggs, Carol; Guthrie, David; Hyde, Keith; Mackie, Ian; Parker, Norman; Popek, Mary; Porter, Neil; Stephens, Clare

    2008-09-01

    This guideline provides a framework for the arrangement of point-of-care testing (POCT) services, previously known as near patient testing (patient self-testing not covered). POCT is defined as any analytical test performed outside the laboratory. Primary users are often non-laboratory healthcare workers. The guidance applies to units within hospitals as well as general practioner surgeries, community clinics and pharmacies. The head of the haematology laboratory or a point of care coordinator must take responsibility for all aspects of the POCT service, including quality and training. Depending on the size and nature of the POCT practice, a local POCT manager may also be required. Equipment selected should have received a successful independent performance evaluation. If an independent evaluation has not been performed the purchaser should assess the device according to the protocol in this document. POCT devices should generate results that are comparable to those of the local laboratory. An accredited external quality assessment programme and internal quality control system must be established. Manufacturers promoting POCT devices designed for non-laboratory sites, e.g. pharmacies, should undertake training and annual competency assessment, perhaps using a web-based system. A diagram to illustrate the stages for the implementation of a POCT service is illustrated.

  1. 78 FR 9108 - Proposed Information Collection (Conduct the Point-of-Care Research Questionnaire) Activity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-07

    ... patient and provider attitudes and willingness to participate in Point-of-Care Research (POC-R). POC-R is... of a Point-of-care research innovation program by assessing the perceptions and attitudes of patients...

  2. Evidence-Based Practice Point-of-Care Resources: A Quantitative Evaluation of Quality, Rigor, and Content.

    PubMed

    Campbell, Jared M; Umapathysivam, Kandiah; Xue, Yifan; Lockwood, Craig

    2015-12-01

    Clinicians and other healthcare professionals need access to summaries of evidence-based information in order to provide effective care to their patients at the point-of-care. Evidence-based practice (EBP) point-of-care resources have been developed and are available online to meet this need. This study aimed to develop a comprehensive list of available EBP point-of-care resources and evaluate their processes and policies for the development of content, in order to provide a critical analysis based upon rigor, transparency and measures of editorial quality to inform healthcare providers and promote quality improvement amongst publishers of EBP resources. A comprehensive and systematic search (Pubmed, CINAHL, and Cochrane Central) was undertaken to identify available EBP point-of-care resources, defined as "web-based medical compendia specifically designed to deliver predigested, rapidly accessible, comprehensive, periodically updated, and evidence-based information (and possibly also guidance) to clinicians." A pair of investigators independently extracted information on general characteristics, content presentation, editorial quality, evidence-based methodology, and breadth and volume. Twenty-seven summary resources were identified, of which 22 met the predefined inclusion criteria for EBP point-of-care resources, and 20 could be accessed for description and assessment. Overall, the upper quartile of EBP point-of-care providers was assessed to be UpToDate, Nursing Reference Centre, Mosby's Nursing Consult, BMJ Best Practice, and JBI COnNECT+. The choice of which EBP point-of-care resources are suitable for an organization is a decision that depends heavily on the unique requirements of that organization and the resources it has available. However, the results presented in this study should enable healthcare providers to make that assessment in a clear, evidence-based manner, and provide a comprehensive list of the available options. © 2015 Sigma Theta Tau

  3. Point-of-care hemoglobin testing for postmortem diagnosis of anemia.

    PubMed

    Na, Joo-Young; Park, Ji Hye; Choi, Byung Ha; Kim, Hyung-Seok; Park, Jong-Tae

    2018-03-01

    An autopsy involves examination of a body using invasive methods such as dissection, and includes various tests using samples procured during dissection. During medicolegal autopsies, the blood carboxyhemoglobin concentration is commonly measured using the AVOXimeter® 4000 as a point-of-care test. When evaluating the body following hypovolemic shock, characteristics such as reduced livor mortis or an anemic appearance of the viscera can be identified, but these observations arequite subjective. Thus, a more objective test is required for the postmortem diagnosis of anemia. In the present study, the AVOXimeter® 4000 was used to investigate the utility of point-of-care hemoglobin testing. Hemoglobin tests were performed in 93 autopsy cases. The AVOXimeter® 4000 and the BC-2800 Auto Hematology Analyzer were used to test identical samples in 29 of these cases. The results of hemoglobin tests performed with these two devices were statistically similar (r = 0.969). The results of hemoglobin tests using postmortem blood were compared with antemortem test results from medical records from 31 cases, and these results were similar. In 13 of 17 cases of death from internal hemorrhage, hemoglobin levels were lower in the cardiac blood than in blood from the affected body cavity, likely due to compensatory changes induced by antemortem hemorrhage. It is concluded that blood hemoglobin testing may be useful as a point-of-care test for diagnosing postmortem anemia.

  4. Development of a digital microfluidic platform for point of care testing

    PubMed Central

    Sista, Ramakrishna; Hua, Zhishan; Thwar, Prasanna; Sudarsan, Arjun; Srinivasan, Vijay; Eckhardt, Allen; Pollack, Michael; Pamula, Vamsee

    2009-01-01

    Point of care testing is playing an increasingly important role in improving the clinical outcome in health care management. The salient features of a point of care device are quick results, integrated sample preparation and processing, small sample volumes, portability, multifunctionality and low cost. In this paper, we demonstrate some of these salient features utilizing an electrowetting-based Digital Microfluidic platform. We demonstrate the performance of magnetic bead-based immunoassays (cardiac troponin I) on a digital microfluidic cartridge in less than 8 minutes using whole blood samples. Using the same microfluidic cartridge, a 40-cycle real-time polymerase chain reaction was performed within 12 minutes by shuttling a droplet between two thermal zones. We further demonstrate, on the same cartridge, the capability to perform sample preparation for bacterial and fungal infectious disease pathogens (methicillin-resistance Staphylococcus aureus and Candida albicans) and for human genomic DNA using magnetic beads. In addition to rapid results and integrated sample preparation, electrowetting-based digital microfluidic instruments are highly portable because fluid pumping is performed electronically. All the digital microfluidic chips presented here were fabricated on printed circuit boards utilizing mass production techniques that keep the cost of the chip low. Due to the modularity and scalability afforded by digital microfluidics, multifunctional testing capability, such as combinations within and between immunoassays, DNA amplification, and enzymatic assays, can be brought to the point of care at a relatively low cost because a single chip can be configured in software for different assays required along the path of care. PMID:19023472

  5. A Novel Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis

    DTIC Science & Technology

    2017-10-01

    AWARD NUMBER: W81XWH-14-2-0195 TITLE: A Novel Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis PRINCIPAL INVESTIGATOR...Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...Month % completion Aim 1: To use simulated field conditions to optimize and produce the established RPA lateral flow diagnostic test for POC

  6. Ultrasound in athletes: emerging techniques in point-of-care practice.

    PubMed

    Yim, Eugene S; Corrado, Gianmichel

    2012-01-01

    Ultrasound offers sports medicine clinicians the potential to diagnose, treat, and manage a broad spectrum of conditions afflicting athletes. This review article highlights applications of ultrasound that hold promise as point-of-care diagnostics and therapeutic tools that can be used directly by clinicians to direct real-time management of athletes. Point-of-care ultrasound has been examined most in the context of musculoskeletal disorders in athletes, with attention given to Achilles tendinopathy, patellar tendinopathy, hip and thigh pathology, elbow tendinopathy, wrist pathology, and shoulder pain. More research has focused on therapeutic applications than diagnostic, but initial evidence has been generated in both. Preliminary evidence has been published also on abdominal ultrasound for splenic enlargement in mononucleosis, cardiopulmonary processes and hydration status, deep vein thrombosis, and bone mineral density. Further research will be required to validate these applications and to explore further applications of portable ultrasound that can be used in the care of athletes.

  7. Direct Comparison of a Tablet Computer and a Personal Digital Assistant for Point-of-Care Documentation in Eye Care

    PubMed Central

    Silvey, Garry M.; Macri, Jennifer M.; Lee, Paul P.; Lobach, David F.

    2005-01-01

    New mobile computing devices including personal digital assistants (PDAs) and tablet computers have emerged to facilitate data collection at the point of care. Unfortunately, little research has been reported regarding which device is optimal for a given care setting. In this study we created and compared functionally identical applications on a Palm operating system-based PDA and a Windows-based tablet computer for point-of-care documentation of clinical observations by eye care professionals when caring for patients with diabetes. Eye-care professionals compared the devices through focus group sessions and through validated usability surveys. We found that the application on the tablet computer was preferred over the PDA for documenting the complex data related to eye care. Our findings suggest that the selection of a mobile computing platform depends on the amount and complexity of the data to be entered; the tablet computer functions better for high volume, complex data entry, and the PDA, for low volume, simple data entry. PMID:16779128

  8. Diagnostic accuracy of point-of-care natriuretic peptide testing for chronic heart failure in ambulatory care: systematic review and meta-analysis.

    PubMed

    Taylor, Kathryn S; Verbakel, Jan Y; Feakins, Benjamin G; Price, Christopher P; Perera, Rafael; Bankhead, Clare; Plüddemann, Annette

    2018-05-21

    To assess the diagnostic accuracy of point-of-care natriuretic peptide tests in patients with chronic heart failure, with a focus on the ambulatory care setting. Systematic review and meta-analysis. Ovid Medline, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, Embase, Health Technology Assessment Database, Science Citation Index, and Conference Proceedings Citation Index until 31 March 2017. Eligible studies evaluated point-of-care natriuretic peptide testing (B-type natriuretic peptide (BNP) or N terminal fragment pro B-type natriuretic peptide (NTproBNP)) against any relevant reference standard, including echocardiography, clinical examination, or combinations of these, in humans. Studies were excluded if reported data were insufficient to construct 2×2 tables. No language restrictions were applied. 42 publications of 39 individual studies met the inclusion criteria and 40 publications of 37 studies were included in the analysis. Of the 37 studies, 30 evaluated BNP point-of-care testing and seven evaluated NTproBNP testing. 15 studies were done in ambulatory care settings in populations with a low prevalence of chronic heart failure. Five studies were done in primary care. At thresholds >100 pg/mL, the sensitivity of BNP, measured with the point-of-care index device Triage, was generally high and was 0.95 (95% confidence interval 0.90 to 0.98) at 100 pg/mL. At thresholds <100 pg/mL, sensitivity ranged from 0.46 to 0.97 and specificity from 0.31 to 0.98. Primary care studies that used NTproBNP testing reported a sensitivity of 0.99 (0.57 to 1.00) and specificity of 0.60 (0.44 to 0.74) at 135 pg/mL. No statistically significant difference in diagnostic accuracy was found between point-of-care BNP and NTproBNP tests. Given the lack of studies in primary care, the paucity of NTproBNP data, and potential methodological limitations in these studies, large scale trials in primary care

  9. Economic Evidence and Point-of-Care Testing

    PubMed Central

    St John, Andrew; Price, Christopher P

    2013-01-01

    Health economics has been an established feature of the research, policymaking, practice and management in the delivery of healthcare. However its role is increasing as the cost of healthcare begins to drive changes in most healthcare systems. Thus the output from cost effectiveness studies is now being taken into account when making reimbursement decisions, e.g. in Australia and the United Kingdom. Against this background it is also recognised that the health economic tools employed in healthcare, and particularly the output from the use of these tools however, are not always employed in the routine delivery of services. One of the notable consequences of this situation is the poor record of innovation in healthcare with respect to the adoption of new technologies, and the realisation of their benefits. The evidence base for the effectiveness of diagnostic services is well known to be limited, and one consequence of this has been a very limited literature on cost effectiveness. One reason for this situation is undoubtedly the reimbursement strategies employed in laboratory medicine for many years, simplistically based on the complexity of the test procedure, and the delivery as a cost-per-test service. This has proved a disincentive to generate the required evidence, and little effort to generate an integrated investment and disinvestment business case, associated with care pathway changes. Point-of-care testing creates a particularly challenging scenario because, on the one hand, the unit cost-per-test is larger through the loss of the economy of scale offered by automation, whilst it offers the potential of substantial savings through enabling rapid delivery of results, and reduction of facility costs. This is important when many health systems are planning for complete system redesign. We review the literature on economic assessment of point-of-care testing in the context of these developments. PMID:24151342

  10. The effects of on-screen, point of care computer reminders on processes and outcomes of care

    PubMed Central

    Shojania, Kaveh G; Jennings, Alison; Mayhew, Alain; Ramsay, Craig R; Eccles, Martin P; Grimshaw, Jeremy

    2014-01-01

    Background The opportunity to improve care by delivering decision support to clinicians at the point of care represents one of the main incentives for implementing sophisticated clinical information systems. Previous reviews of computer reminder and decision support systems have reported mixed effects, possibly because they did not distinguish point of care computer reminders from e-mail alerts, computer-generated paper reminders, and other modes of delivering ‘computer reminders’. Objectives To evaluate the effects on processes and outcomes of care attributable to on-screen computer reminders delivered to clinicians at the point of care. Search methods We searched the Cochrane EPOC Group Trials register, MEDLINE, EMBASE and CINAHL and CENTRAL to July 2008, and scanned bibliographies from key articles. Selection criteria Studies of a reminder delivered via a computer system routinely used by clinicians, with a randomised or quasi-randomised design and reporting at least one outcome involving a clinical endpoint or adherence to a recommended process of care. Data collection and analysis Two authors independently screened studies for eligibility and abstracted data. For each study, we calculated the median improvement in adherence to target processes of care and also identified the outcome with the largest such improvement. We then calculated the median absolute improvement in process adherence across all studies using both the median outcome from each study and the best outcome. Main results Twenty-eight studies (reporting a total of thirty-two comparisons) were included. Computer reminders achieved a median improvement in process adherence of 4.2% (interquartile range (IQR): 0.8% to 18.8%) across all reported process outcomes, 3.3% (IQR: 0.5% to 10.6%) for medication ordering, 3.8% (IQR: 0.5% to 6.6%) for vaccinations, and 3.8% (IQR: 0.4% to 16.3%) for test ordering. In a sensitivity analysis using the best outcome from each study, the median improvement was 5

  11. Pediatric Lung Abscess: Immediate Diagnosis by Point-of-Care Ultrasound.

    PubMed

    Kraft, Clara; Lasure, Benjamin; Sharon, Melinda; Patel, Paulina; Minardi, Joseph

    2018-06-01

    The diagnosis of lung abscess can be difficult to make and often requires imaging beyond plain chest x-ray. The decision to further image with computed tomography should be weighed against the risks of radiation exposure, especially in pediatric patients. In addition, the cost and potential impact on length of stay from obtaining computed tomography scans should be considered. In this report, we describe a case of lung abscess made immediately using point-of-care ultrasound in the emergency department. To our knowledge, there are no previous cases describing lung abscess diagnosed by point-of-care ultrasound. This case report aims to describe a case of pediatric lung abscess, review the ultrasound findings, and discuss relevant literature on the topic.

  12. Chemistry and Heritage

    NASA Astrophysics Data System (ADS)

    Vittoria Barbarulo, Maria

    2014-05-01

    Chemistry is the central science, as it touches every aspect of the society we live in and it is intertwined with many aspects of our culture; in particular, the strong link between Chemistry and Archaeology and Art History is being explored, offering a penetrating insight into an area of growing interest from an educational point of view. A series of vital and vibrant examples (i.e., ancient bronzes composition, colour changes due to natural pigment decomposition, marble degradation) has been proposed, on one hand, to improve student understanding of the relationship between cultural and scientific issues arising from the examination, the conservation, and the maintenance of cultural Heritage, on the other, to illustrate the role of the underlying Chemistry. In some case studies, a survey of the most relevant atmospheric factors, which are involved in the deterioration mechanisms, has also been presented to the students. First-hand laboratory experiences have been providing an invaluable means of discovering the full and varied world of Chemistry. Furthermore, the promotion of an interdisciplinary investigation of a famous painting or fresco, involving the study of its nature and significance, the definition of its historical context, any related literature, the chemical knowledge of the materials used, may be an excellent occasion to experiment the Content and Language Integrated Learning (CLIL). The aim of this approach is to convey the important message that everyone has the responsibility to care for and preserve Heritage for the benefit of present and future generations.

  13. Comparative Evaluations of Randomly Selected Four Point-of-Care Glucometer Devices in Addis Ababa, Ethiopia.

    PubMed

    Wolde, Mistire; Tarekegn, Getahun; Kebede, Tedla

    2018-05-01

    Point-of-care glucometer (PoCG) devices play a significant role in self-monitoring of the blood sugar level, particularly in the follow-up of high blood sugar therapeutic response. The aim of this study was to evaluate blood glucose test results performed with four randomly selected glucometers on diabetes and control subjects versus standard wet chemistry (hexokinase) methods in Addis Ababa, Ethiopia. A prospective cross-sectional study was conducted on randomly selected 200 study participants (100 participants with diabetes and 100 healthy controls). Four randomly selected PoCG devices (CareSens N, DIAVUE Prudential, On Call Extra, i-QARE DS-W) were evaluated against hexokinase method and ISO 15197:2003 and ISO 15197:2013 standards. The minimum and maximum blood sugar values were recorded by CareSens N (21 mg/dl) and hexokinase method (498.8 mg/dl), respectively. The mean sugar values of all PoCG devices except On Call Extra showed significant differences compared with the reference hexokinase method. Meanwhile, all four PoCG devices had strong positive relationship (>80%) with the reference method (hexokinase). On the other hand, none of the four PoCG devices fulfilled the minimum accuracy measurement set by ISO 15197:2003 and ISO 15197:2013 standards. In addition, the linear regression analysis revealed that all four selected PoCG overestimated the glucose concentrations. The overall evaluation of the selected four PoCG measurements were poorly correlated with standard reference method. Therefore, before introducing PoCG devices to the market, there should be a standardized evaluation platform for validation. Further similar large-scale studies on other PoCG devices also need to be undertaken.

  14. Point-of-Care Ultrasonography Findings and Care Use Among Patients Undergoing Ultrasound-Guided Shoulder Injections.

    PubMed

    Lee, Se Won; Tiu, Timothy; Roberts, Jeremy; Lee, Brian; Bartels, Matthew N; Oh-Park, Mooyeon

    2018-01-01

    The aims of the study were to assess the overall reduction of pain in patients undergoing ultrasound-guided shoulder injections and to characterize the preinjection point-of-care ultrasound findings and use of clinical services postinjection including the use of magnetic resonance imaging and surgeries. Data of 172 patients who underwent ultrasound-guided subacromial subdeltoid injection or glenohumeral joint injection were reviewed for preinjection point-of-care ultrasound findings, change in pain intensity at 2 mos from baseline, and use of care at 6 mos' postinjection. Pain intensity was measured by the numeric rating scale and a dichotomous report of global impression of significant improvement in pain. Responders were defined as those with 50% or more reduction in numeric rating scale or those with global impression of 50% or more improvement. There were 141 responders among the 172 patients analyzed. Full-thickness rotator cuff tears were higher in the ultrasound-guided subacromial subdeltoid injection group when compared with the glenohumeral joint injection group (P = 0.038) and abnormal bicipital tendon findings higher in the glenohumeral joint injection group (P = 0.016). There were no significant differences in specific abnormal U findings between responders versus nonresponders. Twelve patients had a shoulder magnetic resonance imaging and four patients underwent operative interventions after the injection. Overall pain reduction after ultrasound-guided shoulder injections was favorable in the short term. There was no specific preinjection point-of-care ultrasound findings associated with clinical pain reduction after injection. Additional imaging and operative intervention after ultrasound-guided shoulder injections seemed to be relatively low.

  15. Saliva Liquid Biopsy for Point-of-Care Applications

    PubMed Central

    Aro, Katri; Wei, Fang; Wong, David T.; Tu, Michael

    2017-01-01

    Saliva is a non-invasive biofluid, which is easy to collect, transport, and store. Because of its accessibility and connection to systemic diseases, saliva is one of the best candidates for the advancement of point-of-care medicine, where individuals are able to easily monitor their health status by using portable convenient tools such as smartphones. There are a variety of scenarios with which saliva can be used: studies have been conducted on using saliva to measure stress hormones, enzyme levels, developmental disease biomarkers, and even cancer mutations. If validated biomarkers were combined with high-quality detection tools, saliva would open up a new frontier in high-quality healthcare, allowing physicians and patients to work together for real-time health monitoring and high-impact personalized preventative medicine. One of the most exciting emerging frontiers of saliva is liquid biopsy, which is a non-invasive means to assess the presence and characteristics of cancer in a patient. This article will review current basic knowledge of biomarkers, review their relation to different diseases and conditions, and explore liquid biopsy for point-of-care applications. PMID:28443278

  16. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    PubMed

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  17. Point-of-care testing: applications of 3D printing.

    PubMed

    Chan, Ho Nam; Tan, Ming Jun Andrew; Wu, Hongkai

    2017-08-08

    Point-of-care testing (POCT) devices fulfil a critical need in the modern healthcare ecosystem, enabling the decentralized delivery of imperative clinical strategies in both developed and developing worlds. To achieve diagnostic utility and clinical impact, POCT technologies are immensely dependent on effective translation from academic laboratories out to real-world deployment. However, the current research and development pipeline is highly bottlenecked owing to multiple restraints in material, cost, and complexity of conventionally available fabrication techniques. Recently, 3D printing technology has emerged as a revolutionary, industry-compatible method enabling cost-effective, facile, and rapid manufacturing of objects. This has allowed iterative design-build-test cycles of various things, from microfluidic chips to smartphone interfaces, that are geared towards point-of-care applications. In this review, we focus on highlighting recent works that exploit 3D printing in developing POCT devices, underscoring its utility in all analytical steps. Moreover, we also discuss key advantages of adopting 3D printing in the device development pipeline and identify promising opportunities in 3D printing technology that can benefit global health applications.

  18. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    PubMed Central

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would

  19. A Review of Online Evidence-based Practice Point-of-Care Information Summary Providers

    PubMed Central

    Liberati, Alessandro; Moschetti, Ivan; Tagliabue, Ludovica; Moja, Lorenzo

    2010-01-01

    Background Busy clinicians need easy access to evidence-based information to inform their clinical practice. Publishers and organizations have designed specific tools to meet doctors’ needs at the point of care. Objective The aim of this study was to describe online point-of-care summaries and evaluate their breadth, content development, and editorial policy against their claims of being “evidence-based.” Methods We searched Medline, Google, librarian association websites, and information conference proceedings from January to December 2008. We included English Web-based point-of-care summaries designed to deliver predigested, rapidly accessible, comprehensive, periodically updated, evidence-based information to clinicians. Two investigators independently extracted data on the general characteristics and content presentation of summaries. We assessed and ranked point-of-care products according to: (1) coverage (volume) of medical conditions, (2) editorial quality, and (3) evidence-based methodology. We explored how these factors were associated. Results We retrieved 30 eligible summaries. Of these products, 18 met our inclusion criteria and were qualitatively described, and 16 provided sufficient data for quantitative evaluation. The median volume of medical conditions covered was 80.6% (interquartile range, 68.9% - 84.2%) and varied for the different products. Similarly, differences emerged for editorial policy (median 8.0, interquartile range 5.8 - 10.3) and evidence-based methodology scores (median 10.0, interquartile range 1.0 - 12.8) on a 15-point scale. None of these dimensions turned out to be significantly associated with the other dimensions (editorial quality and volume, Spearman rank correlation r = -0.001, P = .99; evidence-based methodology and volume, r = -0.19, P = .48; editorial and evidence-based methodology, r = 0.43, P =.09). Conclusions Publishers are moving to develop point-of-care summary products. Some of these have better profiles than

  20. Personal Digital Assistants as Point-of-Care Tools in Long-Term Care Facilities: A Pilot Study

    ERIC Educational Resources Information Center

    Qadri, Syeda S.; Wang, Jia; Ruiz, Jorge G.; Roos, Bernard A.

    2009-01-01

    This study used both survey and interview questionnaires. It was designed to assess the feasibility, usability, and utility of two point-of-care tools especially prepared with information relevant for dementia care by staff nurses in a small, a medium-sized, and a large nursing home in Florida. Twenty-five LPN or RN nurses were recruited for the…

  1. Point of Care Technologies for HIV

    PubMed Central

    Hewlett, Indira K.

    2014-01-01

    Effective prevention of HIV/AIDS requires early diagnosis, initiation of therapy, and regular plasma viral load monitoring of the infected individual. In addition, incidence estimation using accurate and sensitive assays is needed to facilitate HIV prevention efforts in the public health setting. Therefore, more affordable and accessible point-of-care (POC) technologies capable of providing early diagnosis, HIV viral load measurements, and CD4 counts in settings where HIV is most prevalent are needed to enable appropriate intervention strategies and ultimately stop transmission of the virus within these populations to achieve the future goal of an AIDS-free generation. This review discusses the available and emerging POC technologies for future application to these unmet public health needs. PMID:24579041

  2. Point-of-Care Ultrasound for Pulmonary Concerns in Remote Spaceflight Triage Environments.

    PubMed

    Johansen, Benjamin D; Blue, Rebecca S; Castleberry, Tarah L; Antonsen, Erik L; Vanderploeg, James M

    2018-02-01

    With the development of the commercial space industry, growing numbers of spaceflight participants will engage in activities with a risk for pulmonary injuries, including pneumothorax, ebullism, and decompression sickness, as well as other concomitant trauma. Medical triage capabilities for mishaps involving pulmonary conditions have not been systematically reviewed. Recent studies have advocated the use of point-of-care ultrasound to screen for lung injury or illness. The operational utility of portable ultrasound systems in disaster relief and other austere settings may be relevant to commercial spaceflight. A systematic review of published literature was conducted concerning the use of point-of-care pulmonary ultrasound techniques in austere environments, including suggested examination protocols for triage and diagnosis. Recent studies support the utility of pulmonary ultrasound examinations when performed by skilled operators, and comparability of the results to computed tomography and chest radiography for certain conditions, with important implications for trauma management in austere environments. Pulmonary injury and illness are among the potential health risks facing spaceflight participants. Implementation of point-of-care ultrasound protocols could aid in the rapid diagnosis, triage, and treatment of such conditions. Though operator-dependent, ultrasound, with proper training, experience, and equipment, could be a valuable tool in the hands of a first responder supporting remote spaceflight operations.Johansen BD, Blue RS, Castleberry TL, Antonsen EL, Vanderploeg JM. Point-of-care ultrasound for pulmonary concerns in remote spaceflight triage environments. Aerosp Med Hum Perform. 2018; 89(2):122-129.

  3. Health information needs of professional nurses required at the point of care.

    PubMed

    Ricks, Esmeralda; ten Ham, Wilma

    2015-06-11

    Professional nurses work in dynamic environments and need to keep up to date with relevant information for practice in nursing to render quality patient care. Keeping up to date with current information is often challenging because of heavy workload, diverse information needs and the accessibility of the required information at the point of care. The aim of the study was to explore and describe the information needs of professional nurses at the point of care in order to make recommendations to stakeholders to develop a mobile library accessible by means of smart phones when needed. The researcher utilised a quantitative, descriptive survey design to conduct this study. The target population comprised 757 professional nurses employed at a state hospital. Simple random sampling was used to select a sample of the wards, units and departments for inclusion in the study. A convenience sample of 250 participants was selected. Two hundred and fifty structured self-administered questionnaires were distributed amongst the participants. Descriptive statistics were used to analyse the data. A total of 136 completed questionnaires were returned. The findings highlighted the types and accessible sources of information. Information needs of professional nurses were identified such as: extremely drug-resistant tuberculosis, multi-drug-resistant tuberculosis, HIV, antiretrovirals and all chronic lifestyle diseases. This study has enabled the researcher to identify the information needs required by professional nurses at the point of care to enhance the delivery of patient care. The research results were used to develop a mobile library that could be accessed by professional nurses.

  4. The future point-of-care detection of disease and its data capture and handling.

    PubMed

    Lopez-Barbosa, Natalia; Gamarra, Jorge D; Osma, Johann F

    2016-04-01

    Point-of-care detection is a widely studied area that attracts effort and interest from a large number of fields and companies. However, there is also increased interest from the general public in this type of device, which has driven enormous changes in the design and conception of these developments and the way data is handled. Therefore, future point-of-care detection has to include communication with front-end technology, such as smartphones and networks, automation of manufacture, and the incorporation of concepts like the Internet of Things (IoT) and cloud computing. Three key examples, based on different sensing technology, are analyzed in detail on the basis of these items to highlight a route for the future design and development of point-of-care detection devices and their data capture and handling.

  5. Development of paper-based wireless communication modules for point-of-care diagnostic applications

    NASA Astrophysics Data System (ADS)

    Smith, Suzanne; Bezuidenhout, Petroné H.; Land, Kevin; Korvink, Jan G.; Mager, Dario

    2016-02-01

    We present an ultra-high frequency radio frequency identification based wireless communication set-up for paper-based point-of-care diagnostic applications, based on a sensing radio frequency identification chip. Paper provides a low-cost, disposable platform for ease of fluidic handling without bulky instrumentation, and is thus ideally suited for point-ofcare applications; however, result communication - a crucial aspect for healthcare to be implemented effectively - is still lacking. Printing of radio frequency identification antennas and electronic circuitry for sensing on paper are presented, with read out of the results using a radio frequency identification reader illustrated, demonstrating the feasibility of developing integrated, all-printed solutions for point-of-care diagnosis in resource-limited settings.

  6. Comparison of point-of-care-compatible lysis methods for bacteria and viruses.

    PubMed

    Heiniger, Erin K; Buser, Joshua R; Mireles, Lillian; Zhang, Xiaohong; Ladd, Paula D; Lutz, Barry R; Yager, Paul

    2016-09-01

    Nucleic acid sample preparation has been an especially challenging barrier to point-of-care nucleic acid amplification tests in low-resource settings. Here we provide a head-to-head comparison of methods for lysis of, and nucleic acid release from, several pathogenic bacteria and viruses-methods that are adaptable to point-of-care usage in low-resource settings. Digestion with achromopeptidase, a mixture of proteases and peptidoglycan-specific hydrolases, followed by thermal deactivation in a boiling water bath, effectively released amplifiable nucleic acid from Staphylococcus aureus, Bordetella pertussis, respiratory syncytial virus, and influenza virus. Achromopeptidase was functional after dehydration and reconstitution, even after eleven months of dry storage without refrigeration. Mechanical lysis methods proved to be effective against a hard-to-lyse Mycobacterium species, and a miniature bead-mill, the AudioLyse, is shown to be capable of releasing amplifiable DNA and RNA from this species. We conclude that point-of-care-compatible sample preparation methods for nucleic acid tests need not introduce amplification inhibitors, and can provide amplification-ready lysates from a wide range of bacterial and viral pathogens. Copyright © 2016. Published by Elsevier B.V.

  7. Creating a Meeting Point of Understanding: Interpreters' Experiences in Swedish Childhood Cancer Care.

    PubMed

    Granhagen Jungner, Johanna; Tiselius, Elisabet; Lützén, Kim; Blomgren, Klas; Pergert, Pernilla

    2016-01-01

    Children and families with a foreign background and limited Swedish proficiency have to communicate through interpreters in childhood cancer care centers in Sweden. Interpreter-mediated events deal with many difficulties that potentially hinder the transfer of information. The purpose of our study was to explore interpreters' experiences of interpreting between health care staff and limited Swedish proficiency patients/families in childhood cancer care. Using purposive samples, we interviewed 11 interpreters individually. The interviews were analyzed using qualitative content analysis. Analyses of the data resulted in the main theme of creating a meeting point of understanding, constructed from 3 subthemes: balancing between cultures, bridging the gaps of knowledge, and balancing between compassion and professionalism. Our result shows that in order to create a sustainable meeting point of understanding, it is necessary to explain both the context and cultural differences. These results suggest that the responsibility for information transfer lies with both the health care profession and the interpreters. Tools have to be developed for both parties to contribute to creating the meeting point of understanding. © 2015 by Association of Pediatric Hematology/Oncology Nurses.

  8. Electrochemical techniques on sequence-specific PCR amplicon detection for point-of-care applications.

    PubMed

    Luo, Xiaoteng; Hsing, I-Ming

    2009-10-01

    Nucleic acid based analysis provides accurate differentiation among closely affiliated species and this species- and sequence-specific detection technique would be particularly useful for point-of-care (POC) testing for prevention and early detection of highly infectious and damaging diseases. Electrochemical (EC) detection and polymerase chain reaction (PCR) are two indispensable steps, in our view, in a nucleic acid based point-of-care testing device as the former, in comparison with the fluorescence counterpart, provides inherent advantages of detection sensitivity, device miniaturization and operation simplicity, and the latter offers an effective way to boost the amount of targets to a detectable quantity. In this mini-review, we will highlight some of the interesting investigations using the combined EC detection and PCR amplification approaches for end-point detection and real-time monitoring. The promise of current approaches and the direction for future investigations will be discussed. It would be our view that the synergistic effect of the combined EC-PCR steps in a portable device provides a promising detection technology platform that will be ready for point-of-care applications in the near future.

  9. [The added value of information summaries supporting clinical decisions at the point-of-care.

    PubMed

    Banzi, Rita; González-Lorenzo, Marien; Kwag, Koren Hyogene; Bonovas, Stefanos; Moja, Lorenzo

    2016-11-01

    Evidence-based healthcare requires the integration of the best research evidence with clinical expertise and patients' values. International publishers are developing evidence-based information services and resources designed to overcome the difficulties in retrieving, assessing and updating medical information as well as to facilitate a rapid access to valid clinical knowledge. Point-of-care information summaries are defined as web-based medical compendia that are specifically designed to deliver pre-digested, rapidly accessible, comprehensive, and periodically updated information to health care providers. Their validity must be assessed against marketing claims that they are evidence-based. We periodically evaluate the content development processes of several international point-of-care information summaries. The number of these products has increased along with their quality. The last analysis done in 2014 identified 26 products and found that three of them (Best Practice, Dynamed e Uptodate) scored the highest across all evaluated dimensions (volume, quality of the editorial process and evidence-based methodology). Point-of-care information summaries as stand-alone products or integrated with other systems, are gaining ground to support clinical decisions. The choice of one product over another depends both on the properties of the service and the preference of users. However, even the most innovative information system must rely on transparent and valid contents. Individuals and institutions should regularly assess the value of point-of-care summaries as their quality changes rapidly over time.

  10. 75 FR 2549 - Clinical Accuracy Requirements for Point of Care Blood Glucose Meters; Public Meeting; Request...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-15

    ...] Clinical Accuracy Requirements for Point of Care Blood Glucose Meters; Public Meeting; Request for Comments... Requirements for Point of Care Blood Glucose Meters. The purpose of the public meeting is to discuss the clinical accuracy requirements of blood glucose meters and other topics related to their use in point of...

  11. Selecting an A1C Point-of-Care Instrument

    PubMed Central

    Yong, Ee Vonn; Rasinen, Casey

    2015-01-01

    A1C point-of-care (POC) instruments benefit patients with diabetes by facilitating clinician decision making that results in significant glycemic improvements. Three National Glycohemoglobin Standardization Program (NGSP)–certified POC products are available in the United States: the handheld A1CNow (formerly manufactured by Bayer Diabetes Care but now made by Chek Diagnostics) and two bench-top models called the Axis-Shield Afinion Analyzer and the Siemens DCA Vantage. This article compares the three available NGSP-certified POC products in terms of accuracy, precision, ease of use, cost, and additional features. Its goal is to aid health care facilities in conveniently identifying the A1C POC product that best meets their needs. It additionally reviews evidence that supports the continued use of A1C POC instruments in the clinical arena. PMID:26300614

  12. Point of care testing of phospholipase A2 group IIA for serological diagnosis of rheumatoid arthritis

    NASA Astrophysics Data System (ADS)

    Liu, Nathan J.; Chapman, Robert; Lin, Yiyang; Mmesi, Jonas; Bentham, Andrew; Tyreman, Matthew; Abraham, Sonya; Stevens, Molly M.

    2016-02-01

    Secretory phospholipase A2 group IIA (sPLA2-IIA) was examined as a point of care marker for determining disease activity in rheumatoid (RA) and psoriatic (PsA) arthritis. Serum concentration and activity of sPLA2-IIA were measured using in-house antibodies and a novel point of care lateral flow device assay in patients diagnosed with varying severities of RA (n = 30) and PsA (n = 25) and found to correlate strongly with C-reactive protein (CRP). Levels of all markers were elevated in patients with active RA over those with inactive RA as well as both active and inactive PsA, indicating that sPLA2-IIA can be used as an analogue to CRP for RA diagnosis at point of care.Secretory phospholipase A2 group IIA (sPLA2-IIA) was examined as a point of care marker for determining disease activity in rheumatoid (RA) and psoriatic (PsA) arthritis. Serum concentration and activity of sPLA2-IIA were measured using in-house antibodies and a novel point of care lateral flow device assay in patients diagnosed with varying severities of RA (n = 30) and PsA (n = 25) and found to correlate strongly with C-reactive protein (CRP). Levels of all markers were elevated in patients with active RA over those with inactive RA as well as both active and inactive PsA, indicating that sPLA2-IIA can be used as an analogue to CRP for RA diagnosis at point of care. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08423g

  13. Point-of-care ultrasound education for non-physician clinicians in a resource-limited emergency department.

    PubMed

    Stolz, Lori A; Muruganandan, Krithika M; Bisanzo, Mark C; Sebikali, Mugisha J; Dreifuss, Bradley A; Hammerstedt, Heather S; Nelson, Sara W; Nayabale, Irene; Adhikari, Srikar; Shah, Sachita P

    2015-08-01

    To describe the outcomes and curriculum components of an educational programme to train non-physician clinicians working in a rural, Ugandan emergency department in the use of POC ultrasound. The use of point-of-care ultrasound was taught to emergency care providers through lectures, bedsides teaching and hands-on practical sessions. Lectures were tailored to care providers' knowledge base and available therapeutic means. Every ultrasound examination performed by these providers was recorded over 4.5 years. Findings of these examinations were categorised as positive, negative, indeterminate or procedural. Other radiologic studies ordered over this same time period were also recorded. A total of 22,639 patients were evaluated in the emergency department by emergency care providers, and 2185 point-of-care ultrasound examinations were performed on 1886 patients. Most commonly used were the focused assessment with sonography in trauma examination (53.3%) and echocardiography (16.4%). Point-of-care ultrasound studies were performed more frequently than radiology department-performed studies. Positive findings were documented in 46% of all examinations. We describe a novel curriculum for point-of-care ultrasound education of non-physician emergency practitioners in a resource-limited setting. These non-physician clinicians integrated ultrasound into clinical practice and utilised this imaging modality more frequently than traditional radiology department imaging with a large proportion of positive findings. © 2015 John Wiley & Sons Ltd.

  14. Quality of Widely Available Video Instructional Materials for Point-of-Care Ultrasound-Guided Procedure Training in Internal Medicine.

    PubMed

    Khandelwal, Aditi; Devine, Luke A; Otremba, Mirek

    2017-07-01

    Many instructional materials for point-of-care ultrasound (US)-guided procedures exist; however, their quality is unknown. This study assessed widely available educational videos for point-of-care US-guided procedures relevant to internal medicine: central venous catheterization, thoracentesis, and paracentesis. We searched Ovid MEDLINE, YouTube, and Google to identify videos for point-of-care US-guided paracentesis, thoracentesis, and central venous catheterization. Videos were evaluated with a 5-point scale assessing the global educational value and a checklist based on consensus guidelines for competencies in point-of-care US-guided procedures. For point-of-care US-guided central venous catheterization, 12 videos were found, with an average global educational value score ± SD of 4.5 ± 0.7. Indications to abort the procedure were discussed in only 3 videos. Five videos described the indications and contraindications for performing central venous catheterization. For point-of-care US-guided thoracentesis, 8 videos were identified, with an average global educational value score of 4.0 ± 0.9. Only one video discussed indications to abort the procedure, and 3 videos discussed sterile technique. For point-of-care US-guided paracentesis, 7 videos were included, with an average global educational value score of 4.1 ± 0.9. Only 1 video discussed indications to abort the procedure, and 2 described the location of the inferior epigastric artery. The 27 videos reviewed contained good-quality general instruction. However, we noted a lack of safety-related information in most of the available videos. Further development of resources is required to teach internal medicine trainees skills that focus on the safety of point-of-care US guidance. © 2017 by the American Institute of Ultrasound in Medicine.

  15. Microfluidic point-of-care diagnostics for resource-poor environments

    NASA Astrophysics Data System (ADS)

    Laksanasopin, Tassaneewan; Chin, Curtis D.; Moore, Hannah; Wang, Jennifer; Cheung, Yuk Kee; Sia, Samuel K.

    2009-05-01

    Point-of-care (POC) diagnostics have tremendous potential to improve human health in remote and resource-poor settings. However, the design criteria for diagnostic tests appropriate in settings with limited infrastructure are unique and challenging. Here we present a custom optical reader which quantifies silver absorbance from heterogeneous immunoassays. The reader is simple and low-cost and suited for POC diagnostics.

  16. Multi-scale silica structures for improved point of care detection

    NASA Astrophysics Data System (ADS)

    Lin, Sophia; Lin, Lancy; Cho, Eunbyul; Pezzani, Gaston A. O.; Khine, Michelle

    2017-03-01

    The need for sensitive, portable diagnostic tests at the point of care persists. We report on a simple method to obtain improved detection of biomolecules by a two-fold mechanism. Silica (SiO2) is coated on pre-stressed thermoplastic shrink-wrap film. When the film retracts, the resulting micro- and nanostructures yield far-field fluorescence signal enhancements over their planar or wrinkled counterparts. Because the film shrinks by 95% in surface area, there is also a 20x concentration effect. The SiO2 structured substrate is therefore used for improved detection of labeled proteins and DNA hybridization via both fluorescent and bright field. Through optical characterization studies, we attribute the fluorescence signal enhancements of 100x to increased surface density and light scattering from the rough SiO2 structures. Combining with our open channel self-wicking microfluidics, we can achieve extremely low cost yet sensitive point of care diagnostics.

  17. A Necrotizing Fasciitis Fake Out on Point-of-Care Ultrasound-Watch the Shadow.

    PubMed

    Thom, Christopher; Warlaumont, Mary

    2017-04-01

    Point-of-care ultrasound has an increasing role in characterizing soft-tissue infections and has been described previously in the evaluation of necrotizing fasciitis (NF). The identification of air within the soft tissues can be very suggestive of NF in the correct clinical context. A 78-year-old male presented to the emergency department with extensive lower-extremity redness and edema. A point-of-care ultrasound revealed hyperechoic areas within the soft tissues consistent with air, and the patient was taken to surgery and found to have NF. A 60-year-old female presented to the emergency department with physical examination findings consistent with severe cellulitis and associated sepsis. A point-of-care ultrasound revealed hyperechoic areas within the soft tissue that were very similar to the prior case. An emergent surgical consultation was placed due to concern for soft-tissue air and NF. However, these hyperechoic areas were found to be subcutaneous calcifications on subsequent imaging. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Air within the soft tissue is easy to identify on point-of-care ultrasound and can expedite surgical evaluation in cases of suspected NF. Calcifications can mimic the appearance of air on ultrasound and the distinction between these objects can often be made based on the echotexture of the posterior acoustic shadow. Attention to the posterior acoustic shadow can facilitate correct identification of various structures and pathologies in a variety of clinical settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Constitutional dynamic chemistry: bridge from supramolecular chemistry to adaptive chemistry.

    PubMed

    Lehn, Jean-Marie

    2012-01-01

    Supramolecular chemistry aims at implementing highly complex chemical systems from molecular components held together by non-covalent intermolecular forces and effecting molecular recognition, catalysis and transport processes. A further step consists in the investigation of chemical systems undergoing self-organization, i.e. systems capable of spontaneously generating well-defined functional supramolecular architectures by self-assembly from their components, thus behaving as programmed chemical systems. Supramolecular chemistry is intrinsically a dynamic chemistry in view of the lability of the interactions connecting the molecular components of a supramolecular entity and the resulting ability of supramolecular species to exchange their constituents. The same holds for molecular chemistry when the molecular entity contains covalent bonds that may form and break reversibility, so as to allow a continuous change in constitution by reorganization and exchange of building blocks. These features define a Constitutional Dynamic Chemistry (CDC) on both the molecular and supramolecular levels.CDC introduces a paradigm shift with respect to constitutionally static chemistry. The latter relies on design for the generation of a target entity, whereas CDC takes advantage of dynamic diversity to allow variation and selection. The implementation of selection in chemistry introduces a fundamental change in outlook. Whereas self-organization by design strives to achieve full control over the output molecular or supramolecular entity by explicit programming, self-organization with selection operates on dynamic constitutional diversity in response to either internal or external factors to achieve adaptation.The merging of the features: -information and programmability, -dynamics and reversibility, -constitution and structural diversity, points to the emergence of adaptive and evolutive chemistry, towards a chemistry of complex matter.

  19. Primary care requests for anaemia chemistry tests in Spain: potential iron, transferrin and folate over-requesting.

    PubMed

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Leiva-Salinas, Carlos

    2017-09-01

    To study the regional variability of requests for anaemia chemistry tests in primary care in Spain and the associated economic costs of potential over-requesting. Requests for anaemia tests were examined in a cross-sectional study. Clinical laboratories from different autonomous communities (AACCs) were invited to report on primary care anaemia chemistry tests requested during 2014. Demand for iron, ferritin, vitamin B12 and folate tests per 1000 inhabitants and the ratios of the folate/vitamin B12 and transferrin/ferritin requests were compared between AACCs. We also calculated reagent costs and the number of iron, transferrin and folate tests and the economic saving if every AACC had obtained the results achieved by the AACC with best practice. 110 laboratories participated (59.8% of the Spanish population). More than 12 million tests were requested, resulting in reagent costs exceeding €16.5 million. The serum iron test was the most often requested, and the ferritin test was the most costly (over €7 million). Close to €4.5 million could potentially have been saved if iron, transferrin and folate had been appropriately requested (€6 million when extrapolated to the whole Spanish population). The demand for and expenditure on anaemia chemistry tests in primary care in Spain is high, with significant regional differences between different AACCs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Chemistry and Biology

    ERIC Educational Resources Information Center

    Wigston, David L.

    1970-01-01

    Discusses the relationship between chemisty and biology in the science curriculum. Points out the differences in perception of the disciplines, which the physical scientists favoring reductionism. Suggests that biology departments offer a special course for chemistry students, just as the chemistry departments have done for biology students.…

  1. 76 FR 51038 - Draft Guidance for Industry: Cell Selection Devices for Point of Care Production of Minimally...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-17

    ...; formerly Docket No. 2007D-0290] Draft Guidance for Industry: Cell Selection Devices for Point of Care Production of Minimally Manipulated Autologous Peripheral Blood Stem Cells; Withdrawal of Draft Guidance...: Cell Selection Devices for Point of Care Production of Minimally Manipulated Autologous Peripheral...

  2. Are point-of-care (POC) virological tests what is needed?

    PubMed

    Madeley, C R

    2007-07-01

    Point-of-care (POC) tests are becoming more available, although the way in which they should be used is currently undecided. Any 'laboratory'-based diagnosis of respiratory infections has three components: the specimen taken, the test used, and the interpretation of the results. Each of these components needs to be carefully addressed when using POC tests for the diagnosis of respiratory tract infections. Given the enthusiasm with which POC tests are being developed, it is likely that they will be used more and more widely. If so, the advantages and limitations of their use should be fully discussed and the implications recognised.

  3. Design of the POINT study: Pharmacotherapy Optimisation through Integration of a Non-dispensing pharmacist in a primary care Team (POINT).

    PubMed

    Hazen, Ankie C M; Sloeserwij, Vivianne M; Zwart, Dorien L M; de Bont, Antoinette A; Bouvy, Marcel L; de Gier, Johan J; de Wit, Niek J; Leendertse, Anne J

    2015-07-02

    In the Netherlands, 5.6 % of acute hospital admissions are medication-related. Almost half of these admissions are potentially preventable. Reviewing medication in patients at risk in primary care might prevent these hospital admissions. At present, implementation of medication reviews in primary care is suboptimal: pharmacists lack access to patient information, pharmacists are short of clinical knowledge and skills, and working processes of pharmacists (focus on dispensing) and general practitioners (focus on clinical practice) match poorly. Integration of the pharmacist in the primary health care team might improve pharmaceutical care outcomes. The aim of this study is to evaluate the effect of integration of a non-dispensing pharmacist in general practice on the safety of pharmacotherapy in the Netherlands. The POINT study is a non-randomised controlled intervention study with pre-post comparison in an integrated primary care setting. We compare three different models of pharmaceutical care provision in primary care: 1) a non-dispensing pharmacist as an integral member of a primary care team, 2) a pharmacist in a community pharmacy with a predefined training in performing medication reviews and 3) a pharmacist in a community pharmacy (care as usual). In all models, GPs remain accountable for individual medication prescription. In the first model, ten non-dispensing clinical pharmacists are posted in ten primary care practices (including 5 - 10 000 patients each) for a period of 15 months. These non-dispensing pharmacists perform patient consultations, including medication reviews, and share responsibility for the pharmaceutical care provided in the practice. The two other groups consist of ten primary care practices with collaborating pharmacists. The main outcome measurement is the number of medication-related hospital admissions during follow-up. Secondary outcome measurements are potential medication errors, drug burden index and costs. Parallel to this

  4. Precision nutrition - review of methods for point-of-care assessment of nutritional status.

    PubMed

    Srinivasan, Balaji; Lee, Seoho; Erickson, David; Mehta, Saurabh

    2017-04-01

    Precision nutrition encompasses prevention and treatment strategies for optimizing health that consider individual variability in diet, lifestyle, environment and genes by accurately determining an individual's nutritional status. This is particularly important as malnutrition now affects a third of the global population, with most of those affected or their care providers having limited means of determining their nutritional status. Similarly, program implementers often have no way of determining the impact or success of their interventions, thus hindering their scale-up. Exciting new developments in the area of point-of-care diagnostics promise to provide improved access to nutritional status assessment, as a first step towards enabling precision nutrition and tailored interventions at both the individual and community levels. In this review, we focus on the current advances in developing portable diagnostics for assessment of nutritional status at point-of-care, along with the numerous design challenges in this process and potential solutions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Breadth of Coverage, Ease of Use, and Quality of Mobile Point-of-Care Tool Information Summaries: An Evaluation

    PubMed Central

    Ren, Jinma

    2016-01-01

    Background With advances in mobile technology, accessibility of clinical resources at the point of care has increased. Objective The objective of this research was to identify if six selected mobile point-of-care tools meet the needs of clinicians in internal medicine. Point-of-care tools were evaluated for breadth of coverage, ease of use, and quality. Methods Six point-of-care tools were evaluated utilizing four different devices (two smartphones and two tablets). Breadth of coverage was measured using select International Classification of Diseases, Ninth Revision, codes if information on summary, etiology, pathophysiology, clinical manifestations, diagnosis, treatment, and prognosis was provided. Quality measures included treatment and diagnostic inline references and individual and application time stamping. Ease of use covered search within topic, table of contents, scrolling, affordance, connectivity, and personal accounts. Analysis of variance based on the rank of score was used. Results Breadth of coverage was similar among Medscape (mean 6.88), Uptodate (mean 6.51), DynaMedPlus (mean 6.46), and EvidencePlus (mean 6.41) (P>.05) with DynaMed (mean 5.53) and Epocrates (mean 6.12) scoring significantly lower (P<.05). Ease of use had DynaMedPlus with the highest score, and EvidencePlus was lowest (6.0 vs 4.0, respectively, P<.05). For quality, reviewers rated the same score (4.00) for all tools except for Medscape, which was rated lower (P<.05). Conclusions For breadth of coverage, most point-of-care tools were similar with the exception of DynaMed. For ease of use, only UpToDate and DynaMedPlus allow for search within a topic. All point-of-care tools have remote access with the exception of UpToDate and Essential Evidence Plus. All tools except Medscape covered criteria for quality evaluation. Overall, there was no significant difference between the point-of-care tools with regard to coverage on common topics used by internal medicine clinicians. Selection of

  6. [Point-of-care ultrasound in Spanish paediatric intensive care units].

    PubMed

    González Cortés, Rafael; Renter Valdovinos, Luis; Coca Pérez, Ana; Vázquez Martínez, José Luis

    2017-06-01

    Point-of-care (bedside) ultrasound is being increasingly used by paediatricians who treat critically ill children. The aim of this study is to describe its availability, use, and specific training in Paediatric Intensive Care Units in Spain. A descriptive, cross-sectional, multicentre study was performed using an online survey. Of a total of 51 PICUs identified in our country, 64.7% responded to the survey. Just over half (53.1%) have their own ultrasound machine, 25% share it, with other units with the usual location in the PICU, and 21.9% share it, but it is usually located outside the PICU. Ultrasound machine availability was not related to size, care complexity, or number PICU admissions. The ultrasound was used daily in 35% of the units, and was associated with location of the machine in the PICU (P=.026), the existence of a transplant program (P=.009), availability of ECMO (P=.006), and number of admissions (P=.015). 45.5% of PICUs has less than 50% of the medical staff specifically trained in bedside ultrasound, and 18.2% have all their medical staff trained. The presence of more than 50% of medical staff trained was associated with a higher rate of daily use (P=.033), and with specific use to evaluate cardiac function (P=.033), intravascular volume estimation (P=.004), or the presence of intra-abdominal collections (P=.021). Bedside ultrasound is frequently available in Spanish PICUs. Specific training is still variable, but it should serve to enhance its implementation. Copyright © 2016 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Information technology: changing nursing processes at the point-of-care.

    PubMed

    Courtney, Karen L; Demiris, George; Alexander, Greg L

    2005-01-01

    Changing societal demographics, increasing complexity in healthcare knowledge, and increasing nursing shortages have led healthcare strategists to call for a redesign of the healthcare system. Embedded within most redesign recommendations is the increased use of technology to make nursing practice more efficient. However, information technology (IT) has the potential to go beyond simple efficiency increases. If IT is perceived truly as a part of the redesign of healthcare delivery rather than simply the automation of existing processes, then it can change nursing processes within institutions and furthermore change the point-of-care between nurses and patients. Nursing adoption of technology within the workplace is a result of the interactions between technical skills, social acceptance, and workplace culture. Nursing needs for information not only influence their adoption of particular technologies but also shape their design. The objective of this article is to illustrate how IT can change not only nursing practice and processes but also the point-of-care. A case study of the use of IT by nurses in telehomecare is presented and administrative implications are discussed.

  8. Cholesterol Point-of-Care Testing for Community Pharmacies: A Review of the Current Literature.

    PubMed

    Haggerty, Lauren; Tran, Deanna

    2017-08-01

    To summarize the literature on cholesterol point-of-care tests (POCTs). This article would serve as a resource to assist community pharmacists in developing cholesterol point-of-care (POC) pharmacy services. A literature search was performed in MEDLINE Ovid, PubMed, EMBASE, and Cochrane database using the following medical subject headings (MeSH) terms: point-of-care test, cholesterol, blood chemical analysis, rapid testing, collaborative practice, community pharmacy, and ambulatory care. Additional resources including device manufacturer web sites were summarized to supplement the current literature. All human research articles, review articles, meta-analyses, and abstracts published in English through September 1, 2014, were considered. A total of 36 articles were applicable for review. Information was divided into the following categories to be summarized: devices, pharmacists' impact, and operational cost for the pharmacy. The current literature suggests that POCTs in community pharmacies assist with patient outcomes by providing screenings and referring patients with dyslipidemia for further evaluation. The majority of studies on cholesterol POC devices focused on accuracy, revealing the need for further studies to develop best practices and practice models with successful reimbursement. Accuracy, device specifications, required supplies, and patient preference should be considered when selecting a POC device for purchase.

  9. Computational circular dichroism estimation for point-of-care diagnostics via vortex half-wave retarders

    NASA Astrophysics Data System (ADS)

    Haider, Shahid A.; Tran, Megan Y.; Wong, Alexander

    2018-02-01

    Observing the circular dichroism (CD) caused by organic molecules in biological fluids can provide powerful indicators of patient health and provide diagnostic clues for treatment. Methods for this kind of analysis involve tabletop devices that weigh tens of kilograms with costs on the order of tens of thousands of dollars, making them prohibitive in point-of-care diagnostic applications. In an e ort to reduce the size, cost, and complexity of CD estimation systems for point-of-care diagnostics, we propose a novel method for CD estimation that leverages a vortex half-wave retarder in between two linear polarizers and a two-dimensional photodetector array to provide an overall complexity reduction in the system. This enables the measurement of polarization variations across multiple polarizations after they interact with a biological sample, simultaneously, without the need for mechanical actuation. We further discuss design considerations of this methodology in the context of practical applications to point-of-care diagnostics.

  10. Point of care hand hygiene-where's the rub? A survey of US and Canadian health care workers' knowledge, attitudes, and practices.

    PubMed

    Kirk, Jane; Kendall, Anson; Marx, James F; Pincock, Ted; Young, Elizabeth; Hughes, Jillian M; Landers, Timothy

    2016-10-01

    Hand hygiene at the point of care is recognized as a best practice for promoting compliance at the moments when hand hygiene is most critical. The objective of this study was to compare knowledge, attitudes, and practices of US and Canadian frontline health care personnel regarding hand hygiene at the point of care. Physicians and nurses in US and Canadian hospitals were invited to complete a 32-question online survey based on evidence supporting point of care hand hygiene. Eligible health care personnel were in direct clinical practice at least 50% of the time. Three hundred fifty frontline caregivers completed the survey. Among respondents, 57.1% were from the United States and 42.9% were from Canada. Respondents were evenly distributed between physician and nurses. The US and Canadian respondents gave identical ranking to their perceived barriers to hand hygiene compliance. More than half of the respondents from both the United States and Canada agreed or strongly agreed that they would be more likely to clean their hands when recommended if alcohol-based handrub was closer to the patient. This survey demonstrates that similarities between Canada and the United States were more common than not, and the survey raises, or suggests, potential knowledge gaps that require further illumination. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. Evaluation of the i-STAT Point-of-Care Analyzer in Critically Ill Adult Patients

    PubMed Central

    Steinfelder-Visscher, Jacoline; Teerenstra, Steven; Klein Gunnewiek, Jacqueline M.T.; Weerwind, Patrick W.

    2008-01-01

    Abstract: Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. During a 3-month period, 48 blood samples from patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and 42 blood samples from non-cardiac patients who needed intensive care treatment were analyzed on both the i-STAT analyzer (CPB and non-CPB mode, respectively) and our laboratory analyzers (RapidLab 865/Sysmex XE-2100 instrument). The agreement analysis for quantitative data was used to compare i-STAT to RapidLab for blood gas/electrolytes and for hematocrit with the Sysmex instrument. Point-of-care electrolytes and blood gases had constant deviation, except for pH, pO2, and hematocrit. A clear linear trend in deviation of i-STAT from RapidLab was noticed for pH during CPB (r = 0.32, p = .03) and for pO2 > 10 kPa during CPB (r = −0.59, p < .0001 when 10 < pO2 <30 kPa) and in the intensive care unit (r = −0.61, p < .001 when 10 < pO2 <30 kPa). In the normal pO2 range (10.6 < pO2 <13.3 kPa), the performance of the i-STAT was comparable to the RapidLab. In contrast to hematocrit measured during CPB, hematocrit using the non-CPB mode in the non-cardiac intensive care population showed an underestimation up to 2.2% (p < .0001) in the hematocrit range below 25% (n = 11) using the i-STAT. The i-STAT analyzer is suitable for point-of-care testing of electrolytes and blood gases in critically ill patients, except for high pO2. However, the discrepancy in hematocrit bias shows that accuracy established in one patient population cannot be automatically extrapolated to other patient populations, thus stressing the need for separate evaluation. PMID:18389666

  12. Point-of-care blood glucose measurement errors overestimate hypoglycaemia rates in critically ill patients.

    PubMed

    Nya-Ngatchou, Jean-Jacques; Corl, Dawn; Onstad, Susan; Yin, Tom; Tylee, Tracy; Suhr, Louise; Thompson, Rachel E; Wisse, Brent E

    2015-02-01

    Hypoglycaemia is associated with morbidity and mortality in critically ill patients, and many hospitals have programmes to minimize hypoglycaemia rates. Recent studies have established the hypoglycaemic patient-day as a key metric and have published benchmark inpatient hypoglycaemia rates on the basis of point-of-care blood glucose data even though these values are prone to measurement errors. A retrospective, cohort study including all patients admitted to Harborview Medical Center Intensive Care Units (ICUs) during 2010 and 2011 was conducted to evaluate a quality improvement programme to reduce inappropriate documentation of point-of-care blood glucose measurement errors. Laboratory Medicine point-of-care blood glucose data and patient charts were reviewed to evaluate all episodes of hypoglycaemia. A quality improvement intervention decreased measurement errors from 31% of hypoglycaemic (<70 mg/dL) patient-days in 2010 to 14% in 2011 (p < 0.001) and decreased the observed hypoglycaemia rate from 4.3% of ICU patient-days to 3.4% (p < 0.001). Hypoglycaemic events were frequently recurrent or prolonged (~40%), and these events are not identified by the hypoglycaemic patient-day metric, which also may be confounded by a large number of very low risk or minimally monitored patient-days. Documentation of point-of-care blood glucose measurement errors likely overestimates ICU hypoglycaemia rates and can be reduced by a quality improvement effort. The currently used hypoglycaemic patient-day metric does not evaluate recurrent or prolonged events that may be more likely to cause patient harm. The monitored patient-day as currently defined may not be the optimal denominator to determine inpatient hypoglycaemic risk. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Point-of-care ultrasound in aerospace medicine: known and potential applications.

    PubMed

    Wagner, Michael S; Garcia, Kathleen; Martin, David S

    2014-07-01

    Since its initial introduction into the bedside assessment of the trauma patient via the Focused Assessment with Sonography for Trauma (FAST) exam, the use of point-of-care ultrasound has expanded rapidly. A growing body of literature demonstrates ultrasound can be used by nonradiologists as an extension of the physical exam to accurately diagnose or exclude a variety of conditions. These conditions include, but are not limited to, hemoperitoneum, pneumothorax, pulmonary edema, long-bone fracture, deep vein thrombosis, and elevated intracranial pressure. As ultrasound machines have become more compact and portable, their use has extended outside of hospitals to places where the physical exam and diagnostic capabilities may be limited, including the aviation environment. A number of studies using focused sonography have been performed to meet the diagnostic challenges of space medicine. The following article reviews the available literature on portable ultrasound use in aerospace medicine and highlights both known and potential applications of point-of-care ultrasound for the aeromedical clinician.

  14. Caring for the Environment while Teaching Organic Chemistry

    ERIC Educational Resources Information Center

    Santos, Elvira Santos; Gavilan Garcia, Irma Cruz; Lejarazo Gomez, Eva Florencia

    2004-01-01

    A comprehensive program in the field of green chemistry, which concentrates on processing and managing of wastes produced during laboratory experiments, is presented. The primary aim of the program is to instill a sense of responsibility and a concern for the environment through organic chemistry education.

  15. An Instantaneous Low-Cost Point-of-Care Anemia Detection Device

    PubMed Central

    Punter-Villagrasa, Jaime; Cid, Joan; Páez-Avilés, Cristina; Rodríguez-Villarreal, Ivón; Juanola-Feliu, Esteve; Colomer-Farrarons, Jordi; Miribel-Català, Pere Ll.

    2015-01-01

    We present a small, compact and portable device for point-of-care instantaneous early detection of anemia. The method used is based on direct hematocrit measurement from whole blood samples by means of impedance analysis. This device consists of a custom electronic instrumentation and a plug-and-play disposable sensor. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low consumption device making it completely mobile with a long battery life. Another approach could be powering the system based on other solutions like indoor solar cells, or applying energy-harvesting solutions in order to remove the batteries. The sensing system is based on a disposable low-cost label-free three gold electrode commercial sensor for 50 μL blood samples. The device capability for anemia detection has been validated through 24 blood samples, obtained from four hospitalized patients at Hospital Clínic. As a result, the response, effectiveness and robustness of the portable point-of-care device to detect anemia has been proved with an accuracy error of 2.83% and a mean coefficient of variation of 2.57% without any particular case above 5%. PMID:25690552

  16. Satisfaction with the local service point for care: results of an evaluation study

    PubMed Central

    Esslinger, Adelheid Susanne; Macco, Katrin; Schmidt, Katharina

    2009-01-01

    Purpose The market of care increases and is characterized by complexity. Therefore, service points, such as the ‘Zentrale Anlaufstelle Pflege (ZAPf)’ in Nuremberg, are helpful for clients to get orientation. The purpose of the presentation is to show the results of an evaluation study about the clients' satisfaction with the offers of ZAPf. Study Satisfaction with service may be measured with the SERVQUAL concept introduced by Parasuraman et al. (1988). They found out five dimensions of quality (tangibles, reliability, responsiveness, assurances and empathy). We took these dimensions in our study. The study focuses on the quality of service and the benefits recognized by clients. In spring 2007, we conducted 67 interviews by phone, based on a half standardized questionnaire. Statistical analysis was conducted using SPSS. Results The clients want to get information about care in general, financial and legal aspects, alternative care arrangement (e.g. ambulant, long-term care) and typical age-related diseases. They show a high satisfaction with the service provided. Their benefits are to get information and advice, to strengthen the ability of decision taking, to cope with changing situations in life, and to develop solutions. Conclusions The results show that the quality of service is on a high level. Critical success factors are the interdisciplinary cooperation at the service point, based on a regularly and open exchange of information. Every member focuses on an optimal individual solution for the client. Local professional service points act as networkers and brokers. They serve not only for the clients' needs but also support the effective and efficient provision of optimized care.

  17. Hypertriglyceridemic waist phenotype in primary health care: comparison of two cutoff points

    PubMed Central

    Braz, Marina Augusta Dias; Vieira, Jallyne Nunes; Gomes, Flayane Oliveira; da Silva, Priscilla Rafaella; Santos, Ohanna Thays de Medeiros; da Rocha, Ilanna Marques Gomes; de Sousa, Iasmin Matias; Fayh, Ana Paula Trussardi

    2017-01-01

    Objective We aimed to evaluate the prevalence of hypertriglyceridemic waist (HTGW) phenotype among users of primary health care using two different cutoff points used in the literature. Methods We evaluated adults and elderly individuals of both sexes who attended the same level of primary health care. HTGW phenotype was determined with measurements of waist circumference (WC) and triglyceride levels and compared using cutoff points proposed by the National Cholesterol Education Program – NCEP/ATP III (WC ≥102 cm for men and ≥88 cm for women; triglyceride levels ≥150 mg/dL for both sexes) and by Lemieux et al (WC ≥90 cm for men and ≥85 cm for women; triglyceride levels ≥177 mg/dL for both). Results Within the sample of 437 individuals, 73.7% was female. The prevalence of HTGW phenotype was high and statistically different with the use of different cutoff points from the literature. The prevalence was higher using the NCEP/ATP III criteria compared to those proposed by Lemieux et al (36.2% and 32.5%, respectively, p<0.05). Individuals with the presence of the phenotype also presented alterations in other traditional cardiovascular risk markers. Conclusion The HTGW phenotype identified high prevalence of cardiovascular risk in the population, with higher cutoff points from the NCEP/ATP III criteria. The difference in frequency of risk alerts us to the need to establish cutoff points for the Brazilian population. PMID:28979152

  18. What do primary care practitioners want to know? A content analysis of questions asked at the point of care.

    PubMed

    Bjerre, Lise M; Paterson, Nicholas R; McGowan, Jessie; Hogg, William; Campbell, Craig M; Viner, Gary; Archibald, Douglas

    2013-01-01

    Assessing physician needs to develop continuing medical education (CME) activities is an integral part of CME curriculum development. The purpose of the present study was to demonstrate the feasibility of identifying areas of perceived greatest needs for continuing medical education (CME) by using questions collected electronically at the point of care. This study is a secondary analysis of the "Just-in-Time" (JIT) information librarian consultation service database of questions using quantitative content analysis methods. The original JIT project demonstrated the feasibility of a real-time librarian service for answering questions asked by primary care clinicians at the point of care using a Web-based platform or handheld device. Data were collected from 88 primary care practitioners in Ontario, Canada, from October 2005 to April 2006. Questions were answered in less than 15 minutes, enabling clinicians to use the answer during patient encounters. Description of type and frequency of questions asked, including the organ system on which the questions focused, was produced using 2 classification systems, the "taxonomy of generic clinical questions" (TGCQ), and the International Classification for Primary Care version 2 (ICPC-2). Of the original 1889 questions, 1871 (99.0%) were suitable for analysis. A total of 970 (52%) of questions related to therapy; of these, 671 (69.2%) addressed questions about drug therapy, representing 36% of all questions. Questions related to diagnosis (24.8%) and epidemiology (13.5%) were also common. Organ systems questions concerning musculoskeletal, endocrine, skin, cardiac, and digestive systems were asked more than other categories. Questions collected at the point of care provide a valuable and unique source of information on the true learning needs of practicing clinicians. The TGCQ classification allowed us to show that a majority of questions had to do with treatment, particularly drug treatment, whereas the use of the ICPC-2

  19. Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices.

    PubMed

    Verhees, Bart; van Kuijk, Kees; Simonse, Lianne

    2017-12-21

    Point-of-care testing (POCT)-laboratory tests performed with new mobile devices and online technologies outside of the central laboratory-is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP's network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre.

  20. Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices

    PubMed Central

    Verhees, Bart; van Kuijk, Kees

    2017-01-01

    Point-of-care testing (POCT)—laboratory tests performed with new mobile devices and online technologies outside of the central laboratory—is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP’s network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre. PMID:29267224

  1. Rapid Diagnosis of Rhabdomyolysis with Point-of-Care Ultrasound.

    PubMed

    Nassar, Alicia; Talbot, Richard; Grant, Ashley; Derr, Charlotte

    2016-11-01

    It is important to rapidly diagnosis and treat rhabdomyolysis in order to decrease morbidity and mortality. To date there are no reports in the emergency medicine literature on the use of point-of-care ultrasound in the diagnosis of rhabdomyolysis. This unique case describes how ultrasound was used in the emergency department (ED) to quickly diagnose and treat rhabdomyolysis prior to confirmation with an elevated serum creatine kinase. When coupled with a high index of suspicion, ultrasound can be one of the most portable, readily available, low cost, and minimally invasive techniques for making a rapid diagnosis of rhabdomyolysis in the ED.

  2. Barriers and decisions when answering clinical questions at the point of care: a grounded theory study.

    PubMed

    Cook, David A; Sorensen, Kristi J; Wilkinson, John M; Berger, Richard A

    2013-11-25

    Answering clinical questions affects patient-care decisions and is important to continuous professional development. The process of point-of-care learning is incompletely understood. To understand what barriers and enabling factors influence physician point-of-care learning and what decisions physicians face during this process. Focus groups with grounded theory analysis. Focus group discussions were transcribed and then analyzed using a constant comparative approach to identify barriers, enabling factors, and key decisions related to physician information-seeking activities. Academic medical center and outlying community sites. Purposive sample of 50 primary care and subspecialist internal medicine and family medicine physicians, interviewed in 11 focus groups. Insufficient time was the main barrier to point-of-care learning. Other barriers included the patient comorbidities and contexts, the volume of available information, not knowing which resource to search, doubt that the search would yield an answer, difficulty remembering questions for later study, and inconvenient access to computers. Key decisions were whether to search (reasons to search included infrequently seen conditions, practice updates, complex questions, and patient education), when to search (before, during, or after the clinical encounter), where to search (with the patient present or in a separate room), what type of resource to use (colleague or computer), what specific resource to use (influenced first by efficiency and second by credibility), and when to stop. Participants noted that key features of efficiency (completeness, brevity, and searchability) are often in conflict. Physicians perceive that insufficient time is the greatest barrier to point-of-care learning, and efficiency is the most important determinant in selecting an information source. Designing knowledge resources and systems to target key decisions may improve learning and patient care.

  3. Point-of-care test (POCT) INR: hope or illusion?

    PubMed

    Dusse, Luci Maria Sant'Ana; Oliveira, Nataly Carvalho; Rios, Danyelle Romana Alves; Marcolino, Milena Soriano

    2012-01-01

    In the last decade, point-of-care tests were developed to provide rapid generation of test results. These tests have increasingly broad applications. In the area of hemostasis, the international normalized ratio, INR point-of-care test (POCT INR), is the main test of this new proposal. This test has great potential benefit in situations where the quick INR results influences clinical decision making, as in acute ischemic stroke, before surgical procedures and during cardiac surgery. The INR POCT has the potential to be used for self-monitoring of oral anticoagulation in patients under anticoagulant therapy. However, the precision and accuracy of INR POCT still need to be enhanced to increase effectiveness and efficiency of the test. Additionally, the RDC / ANVISA Number 302 makes clear that the POCT testing must be supervised by the technical manager of the Clinical Laboratory in the pre-analytical, analytical and post-analytical. In practice, the Clinical Laboratory does not participate in the implementation of POCT testing or release of the results. Clinicians have high expectation with the incorporation of INR POCT in clinical practice, despite the limitations of this method. These professionals are willing to train the patient to perform the test, but are not legally responsible for the quality of it and are not prepared for the maintenance of equipment. The definition of who is in charge for the test must be one to ensure the quality control.

  4. ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine.

    PubMed

    Flatland, Bente; Freeman, Kathleen P; Vap, Linda M; Harr, Kendal E

    2013-12-01

    Point-of-care testing (POCT) refers to any laboratory testing performed outside the conventional reference laboratory and implies close proximity to patients. Instrumental POCT systems consist of small, handheld or benchtop analyzers. These have potential utility in many veterinary settings, including private clinics, academic veterinary medical centers, the community (eg, remote area veterinary medical teams), and for research applications in academia, government, and industry. Concern about the quality of veterinary in-clinic testing has been expressed in published veterinary literature; however, little guidance focusing on POCT is available. Recognizing this void, the ASVCP formed a subcommittee in 2009 charged with developing quality assurance (QA) guidelines for veterinary POCT. Guidelines were developed through literature review and a consensus process. Major recommendations include (1) taking a formalized approach to POCT within the facility, (2) use of written policies, standard operating procedures, forms, and logs, (3) operator training, including periodic assessment of skills, (4) assessment of instrument analytical performance and use of both statistical quality control and external quality assessment programs, (5) use of properly established or validated reference intervals, (6) and ensuring accurate patient results reporting. Where possible, given instrument analytical performance, use of a validated 13s control rule for interpretation of control data is recommended. These guidelines are aimed at veterinarians and veterinary technicians seeking to improve management of POCT in their clinical or research setting, and address QA of small chemistry and hematology instruments. These guidelines are not intended to be all-inclusive; rather, they provide a minimum standard for maintenance of POCT instruments in the veterinary setting. © 2013 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  5. Smartphone based point-of-care detector of urine albumin

    NASA Astrophysics Data System (ADS)

    Cmiel, Vratislav; Svoboda, Ondrej; Koscova, Pavlina; Provaznik, Ivo

    2016-03-01

    Albumin plays an important role in human body. Its changed level in urine may indicate serious kidney disorders. We present a new point-of-care solution for sensitive detection of urine albumin - the miniature optical adapter for iPhone with in-built optical filters and a sample slot. The adapter exploits smart-phone flash to generate excitation light and camera to measure the level of emitted light. Albumin Blue 580 is used as albumin reagent. The proposed light-weight adapter can be produced at low cost using a 3D printer. Thus, the miniaturized detector is easy to use out of lab.

  6. A Discovery Chemistry Experiment on Buffers

    ERIC Educational Resources Information Center

    Kulevich, Suzanne E.; Herrick, Richard S.; Mills, Kenneth V.

    2014-01-01

    The Holy Cross Chemistry Department has designed and implemented an experiment on buffers as part of our Discovery Chemistry curriculum. The pedagogical philosophy of Discovery Chemistry is to make the laboratory the focal point of learning for students in their first two years of undergraduate instruction. We first pose questions in prelaboratory…

  7. Intensive point-of-care ultrasound training with long-term follow-up in a cohort of Rwandan physicians.

    PubMed

    Henwood, Patricia C; Mackenzie, David C; Rempell, Joshua S; Douglass, Emily; Dukundane, Damas; Liteplo, Andrew S; Leo, Megan M; Murray, Alice F; Vaillancourt, Samuel; Dean, Anthony J; Lewiss, Resa E; Rulisa, Stephen; Krebs, Elizabeth; Raja Rao, A K; Rudakemwa, Emmanuel; Rusanganwa, Vincent; Kyanmanywa, Patrick; Noble, Vicki E

    2016-12-01

    We delivered a point-of-care ultrasound training programme in a resource-limited setting in Rwanda, and sought to determine participants' knowledge and skill retention. We also measured trainees' assessment of the usefulness of ultrasound in clinical practice. This was a prospective cohort study of 17 Rwandan physicians participating in a point-of-care ultrasound training programme. The follow-up period was 1 year. Participants completed a 10-day ultrasound course, with follow-up training delivered over the subsequent 12 months. Trainee knowledge acquisition and skill retention were assessed via observed structured clinical examinations (OSCEs) administered at six points during the study, and an image-based assessment completed at three points. Trainees reported minimal structured ultrasound education and little confidence using point-of-care ultrasound before the training. Mean scores on the image-based assessment increased from 36.9% (95% CI 32-41.8%) before the initial 10-day training to 74.3% afterwards (95% CI 69.4-79.2; P < 0.001). The mean score on the initial OSCE after the introductory course was 81.7% (95% CI 78-85.4%). The mean OSCE performance at each subsequent evaluation was at least 75%, and the mean OSCE score at the 58-week follow up was 84.9% (95% CI 80.9-88.9%). Physicians providing acute care in a resource-limited setting demonstrated sustained improvement in their ultrasound knowledge and skill 1 year after completing a clinical ultrasound training programme. They also reported improvements in their ability to provide patient care and in job satisfaction. © 2016 John Wiley & Sons Ltd.

  8. Optoelectronic Capillary Sensors in Microfluidic and Point-of-Care Instrumentation

    PubMed Central

    Borecki, Michał; Korwin-Pawlowski, Michael L.; Beblowska, Maria; Szmidt, Jan; Jakubowski, Andrzej

    2010-01-01

    This paper presents a review, based on the published literature and on the authors’ own research, of the current state of the art of fiber-optic capillary sensors and related instrumentation as well as their applications, with special emphasis on point-of-care chemical and biochemical sensors, systematizing the various types of sensors from the point of view of the principles of their construction and operation. Unlike classical fiber-optic sensors which rely on changes in light propagation inside the fiber as affected by outside conditions, optical capillary sensors rely on changes of light transmission in capillaries filled with the analyzed liquid, which opens the possibility of interesting new applications, while raising specific issues relating to the construction, materials and instrumentation of those sensors. PMID:22319325

  9. Point of Care- A Novel Approach to Periodontal Diagnosis-A Review

    PubMed Central

    Nayak, Prathibha Anand; Rana, Shivendra

    2017-01-01

    Periodontal disease, one of the prevalent oral diseases, is characterized by gingival inflammation and periodontal tissue destruction. Diagnosing this disease is challenging to the clinicians as the disease process is discontinuous and shows periods of exacerbation and remission. Traditional diagnostic methods basically tells about the past tissue destruction so new diagnostic methods are required which is able to detect the active state of the disease, determine the future progression and also estimates the response to the therapy, thereby helping in the better clinical management of the patient. Both saliva and Gingival crevicular fluid (GCF) are believed to be reliable medium to detect the biomarkers which plays a pivotal role in measuring the disease activity. Keeping these observations in mind rapid chairside tests are developed to diagnose periodontal disease called as Point of Care (POC) diagnostics which simplifies diagnosis and helps in improving the prognosis. This review article highlights about the biomarkers used in the diagnosis and throws light on the various available point of care diagnostic devices. PMID:28969294

  10. [Guidelines for the management of point-of care testing nonconformities according to the EN ISO 22870].

    PubMed

    Houlbert, C; Annaix, V; Szymanowicz, A; Vassault, A; Guimont, M C; Pernet, P

    2012-02-01

    In this paper, guidelines are proposed to fulfill the requirements of EN ISO 22870 standard regarding the management of point-of-care testing (POCT) nonconformities. In the first part, the main nonconformities that may affect POCT are given, the means for resolution and the control of adverse events are proposed. In the second part, we propose recommendations in case of unavailability of a point-of-care testing device from the occurring of the adverse event, to the restarting of the device.

  11. Point-of-Care Diagnostics for Improving Maternal Health in South Africa

    PubMed Central

    Mashamba-Thompson, Tivani P.; Sartorius, Benn; Drain, Paul K.

    2016-01-01

    Improving maternal health is a global priority, particularly in high HIV-endemic, resource-limited settings. Failure to use health care facilities due to poor access is one of the main causes of maternal deaths in South Africa. “Point-of-care” (POC) diagnostics are an innovative healthcare approach to improve healthcare access and health outcomes in remote and resource-limited settings. In this review, POC testing is defined as a diagnostic test that is carried out near patients and leads to rapid clinical decisions. We review the current and emerging POC diagnostics for maternal health, with a specific focus on the World Health Organization (WHO) quality-ASSURED (Affordability, Sensitivity, Specificity, User friendly, Rapid and robust, Equipment free and Delivered) criteria for an ideal point-of-care test in resource-limited settings. The performance of POC diagnostics, barriers and challenges related to implementing POC diagnostics for maternal health in rural and resource-limited settings are reviewed. Innovative strategies for overcoming these barriers are recommended to achieve substantial progress on improving maternal health outcomes in these settings. PMID:27589808

  12. Gold Nanoparticles for Diagnostics: Advances towards Points of Care

    PubMed Central

    Cordeiro, Mílton; Ferreira Carlos, Fábio; Pedrosa, Pedro; Lopez, António; Baptista, Pedro Viana

    2016-01-01

    The remarkable physicochemical properties of gold nanoparticles (AuNPs) have prompted developments in the exploration of biomolecular interactions with AuNP-containing systems, in particular for biomedical applications in diagnostics. These systems show great promise in improving sensitivity, ease of operation and portability. Despite this endeavor, most platforms have yet to reach maturity and make their way into clinics or points of care (POC). Here, we present an overview of emerging and available molecular diagnostics using AuNPs for biomedical sensing that are currently being translated to the clinical setting. PMID:27879660

  13. Point-of-care ultrasound facilitates diagnosing a posterior shoulder dislocation.

    PubMed

    Mackenzie, David C; Liebmann, Otto

    2013-05-01

    Posterior shoulder dislocation is an uncommon disruption of the glenohumeral joint. Risk factors include seizure, electric shock, and underlying instabilities of the shoulder joint. A 27-year-old man with a history of recurrent posterior shoulder dislocation presented to the Emergency Department with sudden shoulder pain and reduced range of motion about the shoulder after abducting and internally rotating his arm. Radiographs did not show fracture or dislocation. The treating physician suspected an occult posterior shoulder dislocation, but wanted to avoid performing a computed tomography scan of the shoulder, as the patient had undergone numerous scans during the evaluation of similar complaints. Instead, a point-of-care ultrasound was performed, demonstrating posterior displacement of the humeral head relative to the glenoid rim, confirming the presence of a posterior shoulder dislocation. The patient received procedural sedation, and the shoulder was reduced with real-time ultrasound visualization. The patient tolerated the procedure well, and had decreased pain and improved range of motion. He was discharged with a sling, swathe, and orthopedic follow-up. Point-of-care ultrasound of the shoulder may be used to demonstrate posterior shoulder dislocation. This may have particular utility in the setting of non-diagnostic radiographs. Copyright © 2013. Published by Elsevier Inc.

  14. Ultra low-cost, portable smartphone optosensors for mobile point-of-care diagnostics

    NASA Astrophysics Data System (ADS)

    Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei

    2018-02-01

    Smartphone optosensors with integrated optical components make mobile point-of-care (MPoC) diagnostics be done near patients' side. It'll especially have a significant impact on healthcare delivery in rural or remote areas. Current FDA-approved PoC devices achieving clinical level are still at high cost and not affordable in rural hospitals. We present a series of ultra low-cost smartphone optical sensing devices for mobile point-of-care diagnosis. Aiming different targeting analytes and sensing mechanisms, we developed custom required optical components for each smartphone optosensros. These optical devices include spectrum readers, colorimetric readers for microplate, lateral flow device readers, and chemiluminescence readers. By integrating our unique designed optical components into smartphone optosening platform, the anlaytes can be precisely detected. Clinical testing results show the clinical usability of our smartphone optosensors. Ultra low-cost portable smartphone optosensors are affordable for rural/remote doctors.

  15. Point-of-care testing in an organ procurement organization donor management setting.

    PubMed

    Baier, K A; Markham, L E; Flaigle, S P; Nelson, P W; Shield, C F; Muruve, N A; Aeder, M I; Murillo, D; Bryan, C F

    2003-01-01

    Our organ procurement organization (OPO) evaluated the clinical and financial efficacy of point-of-care testing (POCT) in management of our deceased organ donors. Before we implemented point-of care testing with the i-STAT into routine clinical donor management, we compared the i-STAT result with the result from the respective donor hospital lab (DHL) for certain analytes on 15 consecutive donors in our OPO from 26 March to 14 May 2001. The financial impact was studied by reviewing 77 donors from July 2001 to March 2002. There was a strong correlation for each analyte between the POC and DHL test results with r-values as follows: pH 0.86; PCO2 = 0.96; PO2 = 0.98; sodium = 0.98; potassium = 0.95; chloride = 0.94; BUN = 0.98; glucose = 0.92; haematocrit = 0.87 and creatinine = 0.95. Since our OPO coordinators began using i-STAT in their routine clinical management of organ donors, they can now more quickly maximize oxygenation and fluid management of the donor and make extra-renal placement calls sooner. Finally, since we are no longer being billed for the testing performed on the i-STAT, average financial savings to our OPO are US dollars 733 per case. Point-of-care testing in management of our OPO donors provides a result that is equivalent to that of the donor hospital lab, has quicker turn-around time than the donor hospital laboratory, allowing more immediate clinical management decisions to be made so that extra-renal offers may begin sooner.

  16. Anesthesiology Point of Care project.

    PubMed

    McDonald, John S; Noback, Carl R; Cheng, Drew; Lee, T K; Nenov, Val

    2002-01-01

    We are developing a dynamic prototype visual communication system for the operating room environs. This has classically been viewed as an isolated and impenetrable workplace. All medical experiences and all teaching remain in a one to one closed loop with no recall or subsequent sharing for the training and education of other colleagues. The "Anesthesia Point of Care" (APOC) concept embraces the sharing of, recording of, and presentation of various physiological and pharmacological events so that real time memory can be shared at a later time for the edification of other colleagues who were not present at the time of the primary learning event. In addition it also provides a remarkably rapid tool for fellow faculty to respond to obvious stress and crisis events that can be broadcast instantly at the time of happening. Finally, it also serves as an efficient and effective means of paging and general communication throughout the daily routines among various healthcare providers in anesthesiology who work as a team unit; these include the staff, residents, CRNAs, physician assistants, and technicians. This system offers a unique opportunity to eventually develop future advanced ideas that can include training exercises, presurgical evaluations, surgical scheduling and improvements in efficiency based upon earlier than expected case completion or conversely later than expected case completion and even as a unique window to development of improved billing itemization and coordination.

  17. Plants and Chemistry: A Teaching Course Based on the Chemistry of Substances of Plant Origin

    NASA Astrophysics Data System (ADS)

    Andreoli, Katia; Calascibetta, Franco; Campanella, Luigi; Favero, Gabriele; Occhionero, Francesca

    2002-08-01

    Over the past few years, we developed an idea about the teaching of chemistry by determining the links between theory and the real world. The principles, concepts, and experimental procedures of chemistry were illustrated through an original approach based on useful substances obtained from plants. The starting point was substances that have always been obtained from trees and vegetables. The approach was implemented during many refresher courses for secondary school teachers of chemistry. The courses were divided into sections, each called "Plants and ...", dedicated to colors, odors, tastes, medicines and drugs, fibers, soaps, and alcoholic beverages. Each section consisted of a theoretical lesson followed by a laboratory session.

  18. Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

    PubMed

    Novo, P; Chu, V; Conde, J P

    2014-07-15

    The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Cancer Survivorship Care Plan Utilization and Impact on Clinical Decision-Making at Point-of-Care Visits with Primary Care: Results from an Engineering, Primary Care, and Oncology Collaborative for Survivorship Health.

    PubMed

    Donohue, SarahMaria; Haine, James E; Li, Zhanhai; Feldstein, David A; Micek, Mark; Trowbridge, Elizabeth R; Kamnetz, Sandra A; Sosman, James M; Wilke, Lee G; Sesto, Mary E; Tevaarwerk, Amye J

    2017-11-02

    Every cancer survivor and his/her primary care provider should receive an individualized survivorship care plan (SCP) following curative treatment. Little is known regarding point-of-care utilization at primary care visits. We assessed SCP utilization in the clinical context of primary care visits. Primary care physicians and advanced practice providers (APPs) who had seen survivors following provision of an SCP were identified. Eligible primary care physicians and APPs were sent an online survey, evaluating SCP utilization and influence on decision-making at the point-of-care, accompanied by copies of the survivor's SCP and the clinic note. Eighty-eight primary care physicians and APPs were surveyed November 2016, with 40 (45%) responding. Most respondents (60%) reported discussing cancer or related issues during the visit. Information needed included treatment (66%) and follow-up visits, and the cancer team was responsible for (58%) vs primary care (58%). Respondents acquired this information by asking the patient (79%), checking oncology notes (75%), the SCP (17%), or online resources (8%). Barriers to SCP use included being unaware of the SCP (73%), difficulty locating it (30%), and finding needed information faster via another mechanism (15%). Despite largely not using the SCP for the visit (90%), most respondents (61%) believed one would be quite or very helpful for future visits. Most primary care visits included discussion of cancer or cancer-related issues. SCPs may provide the information necessary to deliver optimal survivor care but efforts are needed to reduce barriers and design SCPs for primary care use.

  20. Emerging technologies in point-of-care molecular diagnostics for resource-limited settings.

    PubMed

    Peeling, Rosanna W; McNerney, Ruth

    2014-06-01

    Emerging molecular technologies to diagnose infectious diseases at the point at which care is delivered have the potential to save many lives in developing countries where access to laboratories is poor. Molecular tests are needed to improve the specificity of syndromic management, monitor progress towards disease elimination and screen for asymptomatic infections with the goal of interrupting disease transmission and preventing long-term sequelae. In simplifying laboratory-based molecular assays for use at point-of-care, there are inevitable compromises between cost, ease of use and test performance. Despite significant technological advances, many challenges remain for the development of molecular diagnostics for resource-limited settings. There needs to be more advocacy for these technologies to be applied to infectious diseases, increased efforts to lower the barriers to market entry through streamlined and harmonized regulatory approaches, faster policy development for adoption of new technologies and novel financing mechanisms to enable countries to scale up implementation.

  1. Rapid Detection of Ebola Virus with a Reagent-Free, Point-of-Care Biosensor

    PubMed Central

    Baca, Justin T.; Severns, Virginia; Lovato, Debbie; Branch, Darren W.; Larson, Richard S.

    2015-01-01

    Surface acoustic wave (SAW) sensors can rapidly detect Ebola antigens at the point-of-care without the need for added reagents, sample processing, or specialized personnel. This preliminary study demonstrates SAW biosensor detection of the Ebola virus in a concentration-dependent manner. The detection limit with this methodology is below the average level of viremia detected on the first day of symptoms by PCR. We observe a log-linear sensor response for highly fragmented Ebola viral particles, with a detection limit corresponding to 1.9 × 104 PFU/mL prior to virus inactivation. We predict greatly improved sensitivity for intact, infectious Ebola virus. This point-of-care methodology has the potential to detect Ebola viremia prior to symptom onset, greatly enabling infection control and rapid treatment. This biosensor platform is powered by disposable AA batteries and can be rapidly adapted to detect other emerging diseases in austere conditions. PMID:25875186

  2. Perceptions of pharmacists' role in the health care team through student-pharmacist led point-of-care screenings and its future application in health care.

    PubMed

    Bastianelli, Karen M S; Nelson, Lucas; Palombi, Laura

    The public is largely unaware of changing pharmacy roles and continues to underutilize pharmacists as mainly a dispensing service, often overlooking direct patient care components. This paper evaluates the public perceptions of pharmacists' through student led point-of-care screenings and comprehensive medication reviews. An IRB approved longitudinal retrospective study design was used to survey participants who attended College of Pharmacy sponsored health fairs in 2013. The survey contained questions related to patient understanding of the current pharmacy scope of practice, patient's reported level of comfort with the expanding roles of pharmacy, insurance coverage, demographics, income and whom the patients report that they seek first for medical related advice. One hundred participants were surveyed. By a large majority, the health care practitioner that patients reported that they currently sought out for general health information was a physician. All of the participants reported that they considered pharmacists as reliable sources of general health information. Of the 96 participants that completed the survey question regarding their willingness to seek out a pharmacist in the future to have their blood pressure, blood sugar, cholesterol, and/or bone density checked, 89 (92.7%) surveyed answered yes. Only 50 patients (50%) reported being aware that pharmacists have the capability to perform these point-of-care screenings. Participants responded that they felt "comfortable" (78 patients, 83.4%) followed by "trusting" (36 patients, 38.7%). The patients surveyed recognized pharmacists as the medication experts; however, many did not understand the capacity to which pharmacists' scope of practice allows them to deliver care to patients. In this study, almost all of the patients stated that they would consider seeking out a pharmacist to receive point-of-care screenings, but only half were aware that a pharmacist is capable of conducting these screenings. All

  3. A telemedicine model for integrating point-of-care testing into a distributed health-care environment.

    PubMed

    Villalar, J L; Arredondo, M T; Meneu, T; Traver, V; Cabrera, M F; Guillen, S; Del Pozo, F

    2002-01-01

    Centralized testing demands costly laboratories, which are inefficient and may provide poor services. Recent advances make it feasible to move clinical testing nearer to patients and the requesting physicians, thus reducing the time to treatment. Internet technologies can be used to create a virtual laboratory information system in a distributed health-care environment. This allows clinical testing to be transferred to a cooperative scheme of several point-of-care testing (POCT) nodes. Two pilot virtual laboratories were established, one in Italy (AUSL Modena) and one in Greece (Athens Medical Centre). They were constructed on a three-layer model to allow both technical and clinical verification. Different POCT devices were connected. The pilot sites produced good preliminary results in relation to user acceptance, efficiency, convenience and costs. Decentralized laboratories can be expected to become cost-effective.

  4. Chemistry Notes.

    ERIC Educational Resources Information Center

    School Science Review, 1978

    1978-01-01

    Describes some laboratory apparatus, chemistry experiments and demonstrations, such as a Kofler block melting point apparatus, chromatographic investigation of the phosphoric acid, x-ray diffraction, the fountain experiment, endothermic sherbet, the measurement of viscosity, ionization energies and electronic configurations. (GA)

  5. Point of care testing: The impact of nanotechnology.

    PubMed

    Syedmoradi, Leila; Daneshpour, Maryam; Alvandipour, Mehrdad; Gomez, Frank A; Hajghassem, Hassan; Omidfar, Kobra

    2017-01-15

    Point-of-care (POC) diagnostic devices are integral in the health care system and particularly for the diagnosis and monitoring of diseases. POC testing has a variety of advantages including the ability to provide rapid and accurate results, ease of use, low cost, and little need for specialized equipment. One of the goals of POC testing is the development of a chip-based, miniaturized, portable, and self-containing system that allows for the assay of different analytes in complex samples. To achieve these goals, many researchers have focused on paper-based and printed electrode technologies as the material for fabricating POC diagnostic systems. These technologies are affordable, sensitive, user-friendly, rapid, and scalable for manufacturing. Moreover, the combination such devices with nanomaterials provide a path for the development of highly sensitive and selective biosensors for future generation POC tools. This review article discusses present technologies in on-site or at home POC diagnostic assays implemented in paper-based microfluidic and screen printing devices over the past decade as well as in the near future. In addition, recent advances in the application of nanomaterials such as gold nanoparticles, carbon nanotubes (CNTs), magnetic nanoparticles, and graphene in POC devices will be reviewed. The factors that limit POC testing to become real world products and future directions are also identified. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Identifying and Overcoming Obstacles to Point-of-Care Data Collection for Eye Care Professionals

    PubMed Central

    Lobach, David F.; Silvey, Garry M.; Macri, Jennifer M.; Hunt, Megan; Kacmaz, Roje O.; Lee, Paul P.

    2005-01-01

    Supporting data entry by clinicians is considered one of the greatest challenges in implementing electronic health records. In this paper we describe a formative evaluation study using three different methodologies through which we identified obstacles to point-of-care data entry for eye care and then used the formative process to develop and test solutions to overcome these obstacles. The greatest obstacles were supporting free text annotation of clinical observations and accommodating the creation of detailed diagrams in multiple colors. To support free text entry, we arrived at an approach that captures an image of a free text note and associates this image with related data elements in an encounter note. The detailed diagrams included a color pallet that allowed changing pen color with a single stroke and also captured the diagrams as an image associated with related data elements. During observed sessions with simulated patients, these approaches satisfied the clinicians’ documentation needs by capturing the full range of clinical complexity that arises in practice. PMID:16779083

  7. Comparison of three point-of-care blood glucose meters for use in adult and juvenile alpacas.

    PubMed

    Tennent-Brown, Brett S; Koenig, Amie; Williamson, Lisa H; Boston, Raymond C

    2011-08-01

    To compare the performance of 3 point-of-care glucose meters in adult and juvenile alpacas with that of a laboratory-based analyzer. Evaluation study. 35 adult alpacas and 21 juvenile alpacas. Whole blood samples obtained via jugular venipuncture were tested with all 3 point-of-care glucose meters; plasma samples were also tested with 1 of those meters. Glucose concentrations determined by use of the point-of-care meters were compared with results from the laboratory-based analyzer. Plasma glucose concentrations determined by use of the laboratory-based analyzer ranged from 36 to 693 mg/dL. Over the entire range of glucose concentrations tested, the Lin concordance correlation coefficient (agreement) was significant and excellent for all comparisons. Concordance decreased for 1 glucometer when testing whole blood samples over a narrower range of glucose concentrations (50 to 200 mg/dL). Bias was typically small (< 10 mg/dL) for 3 of the 4 comparisons but considerable for 1 meter with the use of whole blood. The limits of agreement were wide for all comparisons over the entire range of glucose concentrations tested but decreased to within acceptable limits when the narrower glucose range (50 to 200 mg/dL) was analyzed for 3 of the comparisons. For samples with a PCV < 25%, bias and the limits of agreement were greater for one of the meters tested. Discrepancies between point-of-care glucose meters and reference techniques can be considerable in alpacas, emphasizing the importance of assessing individual meter performance in a target population.

  8. Systems Engineering and Point of Care Testing: Report from the NIBIB POCT/Systems Engineering Workshop

    PubMed Central

    Stahl, James E; McGowan, Heather; DiResta, Ellen; Gaydos, Charlotte A.; Klapperich, Catherine; Parrish, John; Korte, Brenda

    2015-01-01

    The first part of this manuscript is an introduction to systems engineering and how it may be applied to health care and point of care testing (POCT). Systems engineering is an interdisciplinary field that seeks to better understand and manage changes in complex systems and projects as whole. Systems are sets of interconnected elements which interact with each other, are dynamic, change over time and are subject to complex behaviors. The second part of this paper reports on the results of the National Institute of Biomedical Imaging and Bioengineering (NIBIB) workshop exploring the future of point of care testing and technologies and the recognition that these new technologies do not exist in isolation. That they exist within ecosystems of other technologies and systems; and these systems influence their likelihood of success or failure and their effectiveness. In this workshop, a diverse group of individuals from around the country, from disciplines ranging from clinical care, engineering, regulatory affairs and many others to members of the three major National Institutes of Health (NIH) funded efforts in the areas the Centers for POCT for sexually transmitted disease, POCT for the future of Cancer Care, POCT primary care research network, gathered together for a modified deep dive workshop exploring the current state of the art, mapping probable future directions and developing longer term goals. The invitees were broken up into 4 thematic groups: Home, Outpatient, Public/shared space and Rural/global. Each group proceeded to explore the problem and solution space for point of care tests and technology within their theme. While each thematic area had specific challenges, many commonalities also emerged. This effort thus helped create a conceptual framework for POCT as well as identifying many of the challenges for POCT going forward. Four main dimensions were identified as defining the functional space for both point of care testing and treatment, these are

  9. Systems Engineering and Point of Care Testing: Report from the NIBIB POCT/Systems Engineering Workshop.

    PubMed

    Stahl, James E; McGowan, Heather; DiResta, Ellen; Gaydos, Charlotte A; Klapperich, Catherine; Parrish, John; Korte, Brenda

    2015-03-01

    The first part of this manuscript is an introduction to systems engineering and how it may be applied to health care and point of care testing (POCT). Systems engineering is an interdisciplinary field that seeks to better understand and manage changes in complex systems and projects as whole. Systems are sets of interconnected elements which interact with each other, are dynamic, change over time and are subject to complex behaviors. The second part of this paper reports on the results of the National Institute of Biomedical Imaging and Bioengineering (NIBIB) workshop exploring the future of point of care testing and technologies and the recognition that these new technologies do not exist in isolation. That they exist within ecosystems of other technologies and systems; and these systems influence their likelihood of success or failure and their effectiveness. In this workshop, a diverse group of individuals from around the country, from disciplines ranging from clinical care, engineering, regulatory affairs and many others to members of the three major National Institutes of Health (NIH) funded efforts in the areas the Centers for POCT for sexually transmitted disease, POCT for the future of Cancer Care, POCT primary care research network, gathered together for a modified deep dive workshop exploring the current state of the art, mapping probable future directions and developing longer term goals. The invitees were broken up into 4 thematic groups: Home, Outpatient, Public/shared space and Rural/global. Each group proceeded to explore the problem and solution space for point of care tests and technology within their theme. While each thematic area had specific challenges, many commonalities also emerged. This effort thus helped create a conceptual framework for POCT as well as identifying many of the challenges for POCT going forward. Four main dimensions were identified as defining the functional space for both point of care testing and treatment, these are

  10. Portable Amplifier Design for a Novel EEG Monitor in Point-of-Care Applications.

    PubMed

    Luan, Bo; Sun, Mingui; Jia, Wenyan

    2012-01-01

    The Electroencephalography (EEG) is a common diagnostic tool for neurological diseases and dysfunctions, such as epilepsy and insomnia. However, the current EEG technology cannot be utilized quickly and conveniently at the point of care due to the complex skin preparation procedures required and the inconvenient EEG data acquisition systems. This work presents a portable amplifier design that integrates a set of skin screw electrodes and a wireless data link. The battery-operated amplifier contains an instrumentation amplifier, two noninverting amplifiers, two high-pass filters, and a low-pass filter. It is able to magnify the EEG signals over 10,000 times and has a high impedance, low noise, small size and low weight. Our electrode and amplifier are ideal for point-of-care applications, especially during transportation of patients suffering from traumatic brain injury or stroke.

  11. Rapid detection of Ebola virus with a reagent-free, point-of-care biosensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baca, Justin T.; Severns, Virginia; Lovato, Debbie

    Surface acoustic wave (SAW) sensors can rapidly detect Ebola antigens at the point-of-care without the need for added reagents, sample processing, or specialized personnel. This preliminary study demonstrates SAW biosensor detection of the Ebola virus in a concentration-dependent manner. The detection limit with this methodology is below the average level of viremia detected on the first day of symptoms by PCR. We observe a log-linear sensor response for highly fragmented Ebola viral particles, with a detection limit corresponding to 1.9 × 10⁴ PFU/mL prior to virus inactivation. We predict greatly improved sensitivity for intact, infectious Ebola virus. This point-of-care methodologymore » has the potential to detect Ebola viremia prior to symptom onset, greatly enabling infection control and rapid treatment. This biosensor platform is powered by disposable AA batteries and can be rapidly adapted to detect other emerging diseases in austere conditions.« less

  12. Rapid detection of Ebola virus with a reagent-free, point-of-care biosensor

    DOE PAGES

    Baca, Justin T.; Severns, Virginia; Lovato, Debbie; ...

    2015-04-14

    Surface acoustic wave (SAW) sensors can rapidly detect Ebola antigens at the point-of-care without the need for added reagents, sample processing, or specialized personnel. This preliminary study demonstrates SAW biosensor detection of the Ebola virus in a concentration-dependent manner. The detection limit with this methodology is below the average level of viremia detected on the first day of symptoms by PCR. We observe a log-linear sensor response for highly fragmented Ebola viral particles, with a detection limit corresponding to 1.9 × 10⁴ PFU/mL prior to virus inactivation. We predict greatly improved sensitivity for intact, infectious Ebola virus. This point-of-care methodologymore » has the potential to detect Ebola viremia prior to symptom onset, greatly enabling infection control and rapid treatment. This biosensor platform is powered by disposable AA batteries and can be rapidly adapted to detect other emerging diseases in austere conditions.« less

  13. Value Assessment at the Point of Care: Incorporating Patient Values throughout Care Delivery and a Draft Taxonomy of Patient Values.

    PubMed

    Armstrong, Melissa J; Mullins, C Daniel

    2017-02-01

    Incorporation of patient values is a key element of patient-centered care, but consistent incorporation of patient values at the point of care is lacking. Shared decision making encourages incorporation of patient values in decision making, but associated tools often lack guidance on value assessment. In addition, focusing on patient values relating only to specific decisions misses an opportunity for a more holistic approach to value assessment that could impact other aspects of clinical encounters, including health care planning, communication, and stakeholder involvement. In this commentary, we propose a taxonomy of values underlying patient decision making and provide examples of how these impact provision of health care. The taxonomy describes four categories of patient values: global, decisional, situational, and external. Global values are personal values impacting decision making at a universal level and can include value traits and life priorities. Decisional values are the values traditionally conceptualized in decision making, including considerations such as efficacy, toxicity, quality of life, convenience, and cost. Situational values are values tied to a specific moment in time that modify patients' existing global and decisional values. Finally, discussion of external values acknowledges that many patients consider values other than their own when making decisions. Recognizing the breadth of values impacting patient decision making has implications for both overall health care delivery and shared decision making because value assessments focusing only on decisional values may miss important patient considerations. This draft taxonomy highlights different values impacting decision making and facilitates a more complete value assessment at the point of care. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  14. Organometallic Chemistry and Catalysis in Industry.

    ERIC Educational Resources Information Center

    Parshall, George W.; Putscher, Richard E.

    1986-01-01

    Traces the growth in the industrial usage of organometallic chemistry from 1950 to 1977, pointing out that this growth involved the production of commodity chemicals. Indicates that one of the early successes of organometallic chemistry was the discovery of ethylene polymerization catalysts. (JN)

  15. Wireless Integrated Biosensors for Point-of-Care Diagnostic Applications

    PubMed Central

    Ghafar-Zadeh, Ebrahim

    2015-01-01

    Recent advances in integrated biosensors, wireless communication and power harvesting techniques are enticing researchers into spawning a new breed of point-of-care (POC) diagnostic devices that have attracted significant interest from industry. Among these, it is the ones equipped with wireless capabilities that drew our attention in this review paper. Indeed, wireless POC devices offer a great advantage, that of the possibility of exerting continuous monitoring of biologically relevant parameters, metabolites and other bio-molecules, relevant to the management of various morbid diseases such as diabetes, brain cancer, ischemia, and Alzheimer’s. In this review paper, we examine three major categories of miniaturized integrated devices, namely; the implantable Wireless Bio-Sensors (WBSs), the wearable WBSs and the handheld WBSs. In practice, despite the aforesaid progress made in developing wireless platforms, early detection of health imbalances remains a grand challenge from both the technological and the medical points of view. This paper addresses such challenges and reports the state-of-the-art in this interdisciplinary field. PMID:25648709

  16. [New image of home nursing created by point of care testing (POCT) - examination of issues in the introduction of POCT].

    PubMed

    Hata, Kiyomi

    2014-12-01

    With the rising number of patients who rely on medical care, it is necessary to use evolving health care technology appropriately, to control health care costs, and to enhance the well-being of patients in the home care setting. Point of care testing (POCT)is instrumental system for such demands for home care; however, this term remains relatively unknown in Japan. For this research, I conducted a qualitative analysis of factors based on stories obtained through group interviews of 11 experienced home visiting nurses who work at three home-visit nursing stations for the purpose of clarifying issues in the introduction of POCT. The results of the research identified five categories and 16 subcategories for issues in the introduction of POCT. The identified categories are expected to be useful for the spread of POCT in the future. Key words: Point of care testing, Home care nursing.

  17. 75 FR 54694 - Notice of Availability of a Supplemental Draft Environmental Impact Statement for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-08

    ... Supplemental Draft Environmental Impact Statement for the DesertXpress High-Speed Passenger Rail Project AGENCY... for the DesertXpress High- Speed Passenger Train Project (Project). FRA is the lead agency for the... involve the construction and operation of an interstate high-speed passenger train system between...

  18. Design of a Wireless EEG System for Point-of-Care Applications.

    PubMed

    Jia, Wenyan; Bai, Yicheng; Sun, Mingui; Sclabassi, Robert J

    2013-04-01

    This study aims to develop a wireless EEG system to provide critical point-of-care information about brain electrical activity. A novel dry electrode, which can be installed rapidly, is used to acquire EEG from the scalp. A wireless data link between the electrode and a data port (i.e., a smartphone) is established based on the Bluetooth technology. A prototype of this system has been implemented and its performance in acquiring EEG has been evaluated.

  19. E-health web portals: delivering holistic healthcare and making home the point of care.

    PubMed

    Moody, Linda E

    2005-01-01

    E-health delivers healthcare services and education, via a Web portal, to older persons with chronic conditions and their caregivers and enables the patient's home to be the point of care. This growing industry is ripe for exploration by nurses who can empower the patient and caregiver to gain self-care and coping skills. Advances in information technology now make this dream a reality.

  20. Evidence-Based Point-of-Care Diagnostics: Current Status and Emerging Technologies

    NASA Astrophysics Data System (ADS)

    Chan, Cangel Pui Yee; Mak, Wing Cheung; Cheung, Kwan Yee; Sin, King Keung; Yu, Cheuk Man; Rainer, Timothy H.; Renneberg, Reinhard

    2013-06-01

    Point-of-care (POC) diagnostics brings tests nearer to the site of patient care. The turnaround time is short, and minimal manual interference enables quick clinical management decisions. Growth in POC diagnostics is being continuously fueled by the global burden of cardiovascular and infectious diseases. Early diagnosis and rapid initiation of treatment are crucial in the management of such patients. This review provides the rationale for the use of POC tests in acute coronary syndrome, heart failure, human immunodeficiency virus, and tuberculosis. We also consider emerging technologies that are based on advanced nanomaterials and microfluidics, improved assay sensitivity, miniaturization in device design, reduced costs, and high-throughput multiplex detection, all of which may shape the future development of POC diagnostics.

  1. Single cell HaloChip assay on paper for point-of-care diagnosis.

    PubMed

    Ma, Liyuan; Qiao, Yong; Jones, Ross; Singh, Narendra; Su, Ming

    2016-11-01

    This article describes a paper-based low cost single cell HaloChip assay that can be used to assess drug- and radiation-induced DNA damage at point-of-care. Printing ink on paper effectively blocks fluorescence of paper materials, provides high affinity to charged polyelectrolytes, and prevents penetration of water in paper. After exposure to drug or ionizing radiation, cells are patterned on paper to create discrete and ordered single cell arrays, embedded inside an agarose gel, lysed with alkaline solution to allow damaged DNA fragments to diffuse out of nucleus cores, and form diffusing halos in the gel matrix. After staining DNA with a fluorescent dye, characteristic halos formed around cells, and the level of DNA damage can be quantified by determining sizes of halos and nucleus with an image processing program based on MATLAB. With its low fabrication cost and easy operation, this HaloChip on paper platform will be attractive to rapidly and accurately determine DNA damage for point-of-care evaluation of drug efficacy and radiation condition. Graphical Abstract Single cell HaloChip on paper.

  2. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection.

    PubMed

    Lau, Han Yih; Botella, Jose R

    2017-01-01

    Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR) is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail.

  3. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection

    PubMed Central

    Lau, Han Yih; Botella, Jose R.

    2017-01-01

    Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR) is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail. PMID:29375588

  4. Flexible substrate-based devices for point-of-care diagnostics

    PubMed Central

    Wang, ShuQi; Chinnasamy, Thiruppathiraja; Lifson, Mark; Inci, Fatih; Demirci, Utkan

    2016-01-01

    Point-of-care (POC) diagnostics play an important role in delivering healthcare, particularly for clinical management and disease surveillance in both developed and developing countries. Currently, the majority of POC diagnostics utilize paper substrates owing to their affordability, disposability, and mass production capability. Recently, flexible polymer substrates have been investigated due to their enhanced physicochemical properties, potential to be integrated into wearable devices with wireless communications for personalized health monitoring, and ability to be customized for POC diagnostics. Here, we focus on the latest advances in developing flexible substrate-based diagnostic devices, including paper and polymers, and their clinical applications at the POC. PMID:27344425

  5. Flexible Substrate-Based Devices for Point-of-Care Diagnostics.

    PubMed

    Wang, ShuQi; Chinnasamy, Thiruppathiraja; Lifson, Mark A; Inci, Fatih; Demirci, Utkan

    2016-11-01

    Point-of-care (POC) diagnostics play an important role in delivering healthcare, particularly for clinical management and disease surveillance in both developed and developing countries. Currently, the majority of POC diagnostics utilize paper substrates owing to affordability, disposability, and mass production capability. Recently, flexible polymer substrates have been investigated due to their enhanced physicochemical properties, potential to be integrated into wearable devices with wireless communications for personalized health monitoring, and ability to be customized for POC diagnostics. Here, we focus on the latest advances in developing flexible substrate-based diagnostic devices, including paper and polymers, and their clinical applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Barriers to Point-of-Care Testing in India: Results from Qualitative Research across Different Settings, Users and Major Diseases

    PubMed Central

    Engel, Nora; Ganesh, Gayatri; Patil, Mamata; Yellappa, Vijayashree; Pant Pai, Nitika; Vadnais, Caroline; Pai, Madhukar

    2015-01-01

    Background Successful point-of-care testing, namely ensuring the completion of the test and treat cycle in the same encounter, has immense potential to reduce diagnostic and treatment delays, and impact patient outcomes. However, having rapid tests is not enough, as many barriers may prevent their successful implementation in point-of-care testing programs. Qualitative research on diagnostic practices may help identify such barriers across different points of care in health systems. Methods In this exploratory qualitative study, we conducted 78 semi-structured interviews and 13 focus group discussions in an urban and rural area of Karnataka, India, with healthcare providers (doctors, nurses, specialists, traditional healers, and informal providers), patients, community health workers, test manufacturers, laboratory technicians, program managers and policy-makers. Participants were purposively sampled to represent settings of hospitals, peripheral labs, clinics, communities and homes, in both the public and private sectors. Results In the Indian context, the onus is on the patient to ensure successful point-of-care testing across homes, clinics, labs and hospitals, amidst uncoordinated providers with divergent and often competing practices, in settings lacking material, money and human resources. We identified three overarching themes affecting point-of-care testing: the main theme is ‘relationships’ among providers and between providers and patients, influenced by the cross-cutting theme of ‘infrastructure’. Challenges with both result in ‘modified practices’ often favouring empirical (symptomatic) treatment over treatment guided by testing. Conclusions Even if tests can be conducted on the spot and infrastructure challenges have been resolved, relationships among providers and between patients and providers are crucial for successful point-of-care testing. Furthermore, these barriers do not act in isolation, but are interlinked and need to be examined

  7. C-reactive protein point-of-care testing in acutely ill children: a mixed methods study in primary care.

    PubMed

    Van den Bruel, Ann; Jones, Caroline; Thompson, Matthew; Mant, David

    2016-04-01

    Point-of-care C-reactive protein (CRP) testing of adults with acute respiratory infection in primary care reduces antibiotic prescribing by 22%. The acceptability and impact of CRP testing in children is unknown To determine the acceptability and impact of CRP testing in acutely ill children. Mixed methods study comprising an observational cohort with a nested randomised controlled trial and embedded qualitative study. Children presenting with an acute illness to general practice out-of-hours services; children with a temperature ≥38°C were randomised in the nested trial; parents and clinical staff were invited to the qualitative study. Informed consent rates; parental and staff views on testing. Consent to involvement in the study was obtained for 200/297 children (67.3%, 95% CI 61.7% to 72.6%); the finger-prick test might have been a contributory factor for 63 of the 97 children declining participation but it was cited as a definite factor in only 10 cases. None of the parents or staff raised concerns about the acceptability of testing, describing the pain caused as minor and transient. General practitioner views on the utility of the CRP test were inconsistent. CRP point-of-care testing in children is feasible in primary care and is likely to be acceptable. However, it will not reduce antibiotic prescribing and hospital referrals until general practitioners accept its diagnostic value in children. ISRCTN 69736109. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. A practical guide to self-sustaining point-of-care ultrasound education programs in resource-limited settings.

    PubMed

    Henwood, Patricia C; Mackenzie, David C; Rempell, Joshua S; Murray, Alice F; Leo, Megan M; Dean, Anthony J; Liteplo, Andrew S; Noble, Vicki E

    2014-09-01

    The value of point-of-care ultrasound education in resource-limited settings is increasingly recognized, though little guidance exists on how to best construct a sustainable training program. Herein we offer a practical overview of core factors to consider when developing and implementing a point-of-care ultrasound education program in a resource-limited setting. Considerations include analysis of needs assessment findings, development of locally relevant curriculum, access to ultrasound machines and related technological and financial resources, quality assurance and follow-up plans, strategic partnerships, and outcomes measures. Well-planned education programs in these settings increase the potential for long-term influence on clinician skills and patient care. Copyright © 2014 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  9. Experiences of registered nurses with regard to accessing health information at the point-of-care via mobile computing devices.

    PubMed

    Ricks, Esmeralda; Benjamin, Valencia; Williams, Margaret

    2015-11-19

    The volume of health information necessary to provide competent health care today has become overwhelming. Mobile computing devices are fast becoming an essential clinical tool for accessing health information at the point-of-care of patients. This study explored and described how registered nurses experienced accessing information at the point-of-care via mobile computing devices (MCDs). A qualitative, exploratory, descriptive and contextual design was used. Ten in-depth interviews were conducted with purposively sampled registered nurses employed by a state hospital in the Nelson Mandela Bay Municipality (NMBM). Interviews were recorded, transcribed verbatim and analysed using Tesch's data analysis technique. Ethical principles were adhered to throughout the study. Guba's model of trustworthiness was used to confirm integrity of the study. Four themes emerged which revealed that the registered nurses benefited from the training they received by enabling them to develop, and improve, their computer literacy levels. Emphasis was placed on the benefits that the accessed information had for educational purposes for patients and the public, for colleagues and students. Furthermore the ability to access information at the point-of-care was considered by registered nurses as valuable to improve patient care because of the wide range of accurate and readily accessible information available via the mobile computing device. The registered nurses in this study felt that being able to access information at the point-of-care increased their confidence and facilitated the provision of quality care because it assisted them in being accurate and sure of what they were doing.

  10. Progress in the development of paper-based diagnostics for low-resource point-of-care settings

    PubMed Central

    Byrnes, Samantha; Thiessen, Gregory; Fu, Elain

    2014-01-01

    This Review focuses on recent work in the field of paper microfluidics that specifically addresses the goal of translating the multistep processes that are characteristic of gold-standard laboratory tests to low-resource point-of-care settings. A major challenge is to implement multistep processes with the robust fluid control required to achieve the necessary sensitivity and specificity of a given application in a user-friendly package that minimizes equipment. We review key work in the areas of fluidic controls for automation in paper-based devices, readout methods that minimize dedicated equipment, and power and heating methods that are compatible with low-resource point-of-care settings. We also highlight a focused set of recent applications and discuss future challenges. PMID:24256361

  11. Blister pouches for effective reagent storage and release for low cost point-of-care diagnostic applications

    NASA Astrophysics Data System (ADS)

    Smith, Suzanne; Sewart, Rene; Land, Kevin; Roux, Pieter; Gärtner, Claudia; Becker, Holger

    2016-03-01

    Lab-on-a-chip devices are often applied to point-of-care diagnostic solutions as they are low-cost, compact, disposable, and require only small sample volumes. For such devices, various reagents are required for sample preparation and analysis and, for an integrated solution to be realized, on-chip reagent storage and automated introduction are required. This work describes the implementation and characterization of effective liquid reagent storage and release mechanisms utilizing blister pouches applied to various point-of-care diagnostic device applications. The manufacturing aspects as well as performance parameters are evaluated.

  12. [Point-of-care-testing--the intensive care laboratory].

    PubMed

    Müller, M M; Hackl, W; Griesmacher, A

    1999-01-01

    After successful centralization of laboratory analyses since more than 30 years, advances in biosensors, microprocessors, measurement of undiluted whole blood and miniaturization of laboratory analyzers are leading nowadays more and more to a re-decentralization in the laboratory medicine. Point-of-care-testing (POCT), which is defined as any laboratory test performed outside central or decentralized laboratories, is becoming more and more popular. The theoretical advantages of POCT are faster turn-around-times (TAT), more rapid medical decisions, avoidance of sample identification and sample transport problems and the need of only small specimen volumes. These advantages are frequently mentioned, but are not associated with a clear clinical benefit. The disadvantages of POCT such as incorrect handling and/or maintenance of the analyzers by nontrained clinical staff, inadequate or even absent calibrations and/or quality controls, lack of cost-effectiveness because of an increased number of analyzers and more expensive reagents, insufficient documentation and difficult comparability of the obtained POCT-results with routine laboratory results, are strongly evident. According to the authors' opinion the decision for the establishing of POCT has only to be made in a close co-operation between physicians and laboratorians in order to vouch for necessity and high quality of the analyses. Taking the local situation into consideration (24-h-central laboratory, etc.) the spectrum of parameters measured by means of POCT should be rigorously restricted to the vital functions. Such analytes should be: hemoglobin or hematocrit, activated whole blood clotting time, blood gases, sodium, potassium, ionized calcium, glucose, creatinine, ammonia and lactate.

  13. Using Physics Principles in the Teaching of Chemistry.

    ERIC Educational Resources Information Center

    Gulden, Warren

    1996-01-01

    Presents three examples that show how students can use traditional physics principles or laws for the purpose of understanding chemistry better. Examples include Coulomb's Law and melting points, the Faraday Constant, and the Rydberg Constant. Presents a list of some other traditional topics in a chemistry course that could be enhanced by the…

  14. High-fidelity, simulation-based, interdisciplinary operating room team training at the point of care.

    PubMed

    Paige, John T; Kozmenko, Valeriy; Yang, Tong; Paragi Gururaja, Ramnarayan; Hilton, Charles W; Cohn, Isidore; Chauvin, Sheila W

    2009-02-01

    The operating room (OR) is a dynamic, high risk setting requiring effective teamwork for the safe delivery of care. Teamwork in the modern OR, however, is less than ideal. High fidelity simulation is an attractive approach to training key teamwork competencies. We have developed a portable simulation platform, the mobile mock OR (MMOR) that permits bringing team training over long distances to the point of care. We examined the effectiveness of this innovative, simulation-based interdisciplinary operating room (OR) team training model on its participants. All general surgical OR team members at an academic affiliated medical center underwent scenario-based training using a mobile mock OR. Pre- and post-session mean scores were calculated and analyzed for 15 Likert-type items measuring self-efficacy in teamwork competencies using t test. The mean gain in pre-post item scores for 38 participants averaged 0.4 units on a 6-point Likert scale. The significance was demonstrated in 4 of the items: role clarity (Delta = 0.6 units, P = .02), anticipatory response (Delta = 0.6 units, P = .01), cross monitoring (Delta = 0.6 units, P < .01), and team cohesion and interaction (Delta = 0.7 units, P < .01). High-fidelity, simulation-based OR team training at the point of care positively impacts self-efficacy for effective teamwork performance in everyday practice.

  15. Paper-basd surface enhanced Raman spectroscopy of pnenobarbital sodium for point-of-care therapeutic drug monitoring

    NASA Astrophysics Data System (ADS)

    Yokoyama, Moe; Yamada, Kenji; Nishimura, Takahiro; Kido, Michiko; Jeong, Hieyong; Ohno, Yuko

    2015-03-01

    Therapeutic drug monitoring (TDM) contributes to safe and effective pharmacotherapy in clinical fields. A simple, rapid, low-cost, and minimally-invasive drug measurement method attracts much interest for point-of-care TDM. Tear fluids can be collected minimally-invasively compared to blood sampling and there is a correlation between a drug concentration in tears and that in bloods. Surface enhanced Raman spectroscopy (SERS) with paper-based substrate is useful for point-of-care TDM owing to inexpensiveness and high-sensitivity. Paper is also a safe tear collection tool. Then we are studying on a paper-based SERS of tear specimen for point-of-care TDM. In this paper, to improve sensitivity in measuring drug concentration in tear fluids, we fabricated a SERS substrate by coating gold nano-rods on a paper substrate and evaluated whether the fabricated substrate can enhance Raman scattering. Sodium phenobarbital (PB), an anti-convulsant agent, was used as a target. In experiment, the fabricated substrate indicated the lower detection limit of PB in a solution than a plain paper substrate. This result showed the potential of the paper based SERS substrate to measure drug concentration in tears simply and inexpensively.

  16. A 'green button' for using aggregate patient data at the point of care.

    PubMed

    Longhurst, Christopher A; Harrington, Robert A; Shah, Nigam H

    2014-07-01

    Randomized controlled trials have traditionally been the gold standard against which all other sources of clinical evidence are measured. However, the cost of conducting these trials can be prohibitive. In addition, evidence from the trials frequently rests on narrow patient-inclusion criteria and thus may not generalize well to real clinical situations. Given the increasing availability of comprehensive clinical data in electronic health records (EHRs), some health system leaders are now advocating for a shift away from traditional trials and toward large-scale retrospective studies, which can use practice-based evidence that is generated as a by-product of clinical processes. Other thought leaders in clinical research suggest that EHRs should be used to lower the cost of trials by integrating point-of-care randomization and data capture into clinical processes. We believe that a successful learning health care system will require both approaches, and we suggest a model that resolves this escalating tension: a "green button" function within EHRs to help clinicians leverage aggregate patient data for decision making at the point of care. Giving clinicians such a tool would support patient care decisions in the absence of gold-standard evidence and would help prioritize clinical questions for which EHR-enabled randomization should be carried out. The privacy rule in the Health Insurance Portability and Accountability Act (HIPAA) of 1996 may require revision to support this novel use of patient data. Project HOPE—The People-to-People Health Foundation, Inc.

  17. Handheld tools assess medical necessity at the point of care.

    PubMed

    Pollard, Dan

    2002-01-01

    An emerging strategy to manage financial risk in clinical practice is to involve the physician at the point of care. Using handheld technology, encounter-specific information along with medical necessity policy can be presented to physicians allowing them to integrate it into their medical decision-making process. Three different strategies are discussed: reference books or paper encounter forms, electronic reference tools, and integrated process tools. The electronic reference tool strategy was evaluated and showed a return on investment exceeding 1200% due to reduced overhead costs associated with rework of claim errors.

  18. Evidence-based point-of-care tests and device designs for disaster preparedness.

    PubMed

    Brock, T Keith; Mecozzi, Daniel M; Sumner, Stephanie; Kost, Gerald J

    2010-01-01

    To define pathogen tests and device specifications needed for emerging point-of-care (POC) technologies used in disasters. Surveys included multiple-choice and ranking questions. Multiple-choice questions were analyzed with the chi2 test for goodness-of-fit and the binomial distribution test. Rankings were scored and compared using analysis of variance and Tukey's multiple comparison test. Disaster care experts on the editorial boards of the American Journal of Disaster Medicine and the Disaster Medicine and Public Health Preparedness, and the readers of the POC Journal. Vibrio cholera and Staphylococcus aureus were top-ranked pathogens for testing in disaster settings. Respondents felt that disaster response teams should be equipped with pandemic infectious disease tests for novel 2009 H1N1 and avian H5N1 influenza (disaster care, p < 0.05; POC, p < 0.01). In disaster settings, respondents preferred self-contained test cassettes (disaster care, p < 0.05; POC, p < 0.001) for direct blood sampling (POC, p < 0.01) and disposal of biological waste (disaster care, p < 0.05; POC, p < 0.001). Multiplex testing performed at the POC was preferred in urgent care and emergency room settings. Evidence-based needs assessment identifies pathogen detection priorities in disaster care scenarios, in which Vibrio cholera, methicillin-sensitive and methicillin-resistant Staphylococcus aureus, and Escherichia coli ranked the highest. POC testing should incorporate setting-specific design criteria such as safe disposable cassettes and direct blood sampling at the site of care.

  19. Point-of-care test identifies diabetic ketoacidosis at triage.

    PubMed

    Naunheim, Rosanne; Jang, Timothy J; Banet, Gerald; Richmond, Alec; McGill, Janet

    2006-06-01

    Diabetic ketoacidosis (DKA) is a common, life-threatening complication of diabetes. The diagnosis of DKA relies on signs and symptoms, plus laboratory findings of blood glucose (BG) of > 250 mg/dL, an anion gap (AG) of > or = 15 mmol/L, and carbon dioxide (CO2) of < or = 18 mmol/L when other causes of acidosis are excluded. To compare the results of a point-of-care test for the ketone beta-hydroxybutyrate (beta-OHB) with standard measures for accuracy in predicting DKA. After providing informed consent, 160 patients who presented with BG of > 250 mg/dL underwent testing for beta-OHB with the Precision Xtra meter (Abbott Laboratories, North Chicago, IL) at triage in a large urban hospital emergency department. The diagnosis of DKA was made by clinicians by using standard clinical criteria without knowledge of the beta-OHB test. A diagnosis of DKA was made in 57 of 160 subjects. The beta-OHB values correlated strongly with AG (r = 0.66, p < 0.001) and with CO2 (r = -0.69, p < 0.001), as well as with glucose (r = 0.31, p < 0.001). Cross-classification of DKA vs. beta-OHB yielded sensitivity of 98% (95% CI = 91% to 100%), specificity of 85% (95% CI = 78% to 91%), with a positive likelihood ratio of 6.7 (95% CI = 4.22 to 10.78), and negative likelihood ratio of 0.021 (95% CI = 0.003 to 0.144) at the manufacturer-suggested beta-OHB level of 1.5. The point-of-care test for beta-OHB was as sensitive as more established indicators of DKA. It is more useful than glucose alone for the diagnosis of DKA and offers immediate diagnosis of patients at triage.

  20. The Point-of-Care Laboratory in Clinical Microbiology

    PubMed Central

    Michel-Lepage, Audrey; Boyer, Sylvie; Raoult, Didier

    2016-01-01

    SUMMARY Point-of-care (POC) laboratories that deliver rapid diagnoses of infectious diseases were invented to balance the centralization of core laboratories. POC laboratories operate 24 h a day and 7 days a week to provide diagnoses within 2 h, largely based on immunochromatography and real-time PCR tests. In our experience, these tests are conveniently combined into syndrome-based kits that facilitate sampling, including self-sampling and test operations, as POC laboratories can be operated by trained operators who are not necessarily biologists. POC laboratories are a way of easily providing clinical microbiology testing for populations distant from laboratories in developing and developed countries and on ships. Modern Internet connections enable support from core laboratories. The cost-effectiveness of POC laboratories has been established for the rapid diagnosis of tuberculosis and sexually transmitted infections in both developed and developing countries. PMID:27029593

  1. Point-of-care C-reactive protein-based tuberculosis screening for people living with HIV: a diagnostic accuracy study.

    PubMed

    Yoon, Christina; Semitala, Fred C; Atuhumuza, Elly; Katende, Jane; Mwebe, Sandra; Asege, Lucy; Armstrong, Derek T; Andama, Alfred O; Dowdy, David W; Davis, J Luke; Huang, Laurence; Kamya, Moses; Cattamanchi, Adithya

    2017-12-01

    Symptom-based screening for tuberculosis is recommended for all people living with HIV. This recommendation results in unnecessary Xpert MTB/RIF testing in many individuals living in tuberculosis-endemic areas and thus poor implementation of intensified case finding and tuberculosis preventive therapy. Novel approaches to tuberculosis screening are needed to help achieve global targets for tuberculosis elimination. We assessed the performance of C-reactive protein (CRP) measured with a point-of-care assay as a screening tool for active pulmonary tuberculosis. For this prospective study, we enrolled adults (aged ≥18 years) living with HIV with CD4 cell count less than or equal to 350 cells per μL who were initiating antiretroviral therapy (ART) from two HIV/AIDS clinics in Uganda. CRP concentrations were measured at study entry with a point-of-care assay using whole blood obtained by fingerprick (concentration ≥10 mg/L defined as screen positive for tuberculosis). Sputum samples were collected for Xpert MTB/RIF testing and culture. We calculated the sensitivity and specificity of point-of-care CRP and WHO symptom-based screening in reference to culture results. We repeated the sensitivity analysis with Xpert MTB/RIF as the reference standard. Between July 8, 2013, and Dec 15, 2015, 1237 HIV-infected adults were enrolled and underwent point-of-care CRP testing. 60 (5%) patients with incomplete or contaminated cultures were excluded from the analysis. Of the remaining 1177 patients (median CD4 count 165 cells per μL [IQR 75-271]), 163 (14%) had culture-confirmed tuberculosis. Point-of-care CRP testing had 89% sensitivity (145 of 163, 95% CI 83-93) and 72% specificity (731 of 1014, 95% CI 69-75) for culture-confirmed tuberculosis. Compared with WHO symptom-based screening, point-of-care CRP testing had lower sensitivity (difference -7%, 95% CI -12 to -2; p=0·002) but substantially higher specificity (difference 58%, 95% CI 55 to 61; p<0·0001). When Xpert MTB

  2. Design of point-of-care (POC) microfluidic medical diagnostic devices

    NASA Astrophysics Data System (ADS)

    Leary, James F.

    2018-02-01

    Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically < 15 minutes) medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.

  3. Effects of an Intellectually Caring Model on Urban African American Alternative High School Students' Conceptual Change and Achievement in Chemistry

    ERIC Educational Resources Information Center

    Wood, Lynda C.; Ebenezer, Jazlin; Boone, Relena

    2013-01-01

    The purpose of this article is to study the effects of an intellectually caring model of teaching and learning on alternative African American high school students' conceptual change and achievement in a chemistry unit on acids and bases. A mixed-methods approach using retrospective data was utilized. Data secured from the teacher were the…

  4. Point-of-care rare cell cancer diagnostics.

    PubMed

    Issadore, David

    2015-01-01

    The sparse cells that are shed from tumors into peripheral circulation are an increasingly promising resource for noninvasive monitoring of cancer progression, early diagnosis of disease, and serve as a tool for improving our understanding of cancer metastasis. However, the extremely sparse concentration of circulating tumor cells (CTCs) in blood (~1-100 CTC in 7.5 mL of blood) as well as their heterogeneous biomarker expression has limited their detection using conventional laboratory techniques. To overcome these challenges, we have developed a microfluidic chip-based micro-Hall detector (μHD), which can directly measure single, immunomagnetically tagged cells in whole blood. The μHD can detect individual cells even in the presence of vast numbers of blood cells and unbound reactants, and does not require any washing or purification steps. Furthermore, this cost-effective, single-cell analytical technique is well suited for miniaturization into a mobile platform for low-cost point-of-care use. In this chapter, we describe the methodology used to design, fabricate, and apply these chips to cancer diagnostics.

  5. External quality assurance for HIV point-of-care testing in Africa: A collaborative country-partner approach to strengthen diagnostic services

    PubMed Central

    2016-01-01

    It is important to consider the role of diagnostics and the critical need for quality diagnostics services in resource-limited settings. Accurate diagnostic tests play a key role in patient management and the prevention and control of most infectious diseases. As countries plan for implementation of HIV early infant diagnosis and viral load point-of-care testing, the London School of Hygiene & Tropical Medicine has worked with countries and partners with an interest in external quality assurance to support quality point-of-care testing on the continent. Through a series of collaborative consultations and workshops, the London School of Hygiene & Tropical Medicine has gathered lessons learned, tools, and resources and developed quality assurance models that will support point-of-care testing. The London School of Hygiene & Tropical Medicine is committed to the continued advancement of laboratory diagnostics in Africa and quality laboratory services and point-of-care testing. PMID:28879132

  6. Current Nucleic Acid Extraction Methods and Their Implications to Point-of-Care Diagnostics.

    PubMed

    Ali, Nasir; Rampazzo, Rita de Cássia Pontello; Costa, Alexandre Dias Tavares; Krieger, Marco Aurelio

    2017-01-01

    Nucleic acid extraction (NAE) plays a vital role in molecular biology as the primary step for many downstream applications. Many modifications have been introduced to the original 1869 method. Modern processes are categorized into chemical or mechanical, each with peculiarities that influence their use, especially in point-of-care diagnostics (POC-Dx). POC-Dx is a new approach aiming to replace sophisticated analytical machinery with microanalytical systems, able to be used near the patient, at the point of care or point of need . Although notable efforts have been made, a simple and effective extraction method is still a major challenge for widespread use of POC-Dx. In this review, we dissected the working principle of each of the most common NAE methods, overviewing their advantages and disadvantages, as well their potential for integration in POC-Dx systems. At present, it seems difficult, if not impossible, to establish a procedure which can be universally applied to POC-Dx. We also discuss the effects of the NAE chemicals upon the main plastic polymers used to mass produce POC-Dx systems. We end our review discussing the limitations and challenges that should guide the quest for an efficient extraction method that can be integrated in a POC-Dx system.

  7. Current Nucleic Acid Extraction Methods and Their Implications to Point-of-Care Diagnostics

    PubMed Central

    Ali, Nasir; Rampazzo, Rita de Cássia Pontello; Krieger, Marco Aurelio

    2017-01-01

    Nucleic acid extraction (NAE) plays a vital role in molecular biology as the primary step for many downstream applications. Many modifications have been introduced to the original 1869 method. Modern processes are categorized into chemical or mechanical, each with peculiarities that influence their use, especially in point-of-care diagnostics (POC-Dx). POC-Dx is a new approach aiming to replace sophisticated analytical machinery with microanalytical systems, able to be used near the patient, at the point of care or point of need. Although notable efforts have been made, a simple and effective extraction method is still a major challenge for widespread use of POC-Dx. In this review, we dissected the working principle of each of the most common NAE methods, overviewing their advantages and disadvantages, as well their potential for integration in POC-Dx systems. At present, it seems difficult, if not impossible, to establish a procedure which can be universally applied to POC-Dx. We also discuss the effects of the NAE chemicals upon the main plastic polymers used to mass produce POC-Dx systems. We end our review discussing the limitations and challenges that should guide the quest for an efficient extraction method that can be integrated in a POC-Dx system. PMID:28785592

  8. Applications of everyday IT and communications devices in modern analytical chemistry: A review.

    PubMed

    Grudpan, Kate; Kolev, Spas D; Lapanantnopakhun, Somchai; McKelvie, Ian D; Wongwilai, Wasin

    2015-05-01

    This paper reviews the development and recent use of everyday communications and IT equipment (mobile phones, digital cameras, scanners, webcams, etc) as detection devices for colorimetric chemistries. Such devices can readily be applied for visible detection using reaction formats such as microfluidic paper based analytical devices (µPADs), indicator papers, and well plate reaction vessels. Their use is highly advantageous with respect to cost, simplicity and portability, and offers many opportunities in the areas of point of care diagnosis, and at-site monitoring of environmental, agricultural, food and beverage parameters. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Nucleic-acid testing, new platforms and nanotechnology for point-of-decision diagnosis of animal pathogens.

    PubMed

    Teles, Fernando; Fonseca, Luís

    2015-01-01

    Accurate disease diagnosis in animals is crucial for animal well-being but also for preventing zoonosis transmission to humans. In particular, livestock diseases may constitute severe threats to humans due to the particularly high physical contact and exposure and, also, be the cause of important economic losses, even in non-endemic countries, where they often arise in the form of rapid and devastating epidemics. Rapid diagnostic tests have been used for a long time in field situations, particularly during outbreaks. However, they mostly rely on serological approaches, which may confirm the exposure to a particular pathogen but may be inappropriate for point-of-decision (point-of-care) settings when emergency responses supported on early and accurate diagnosis are required. Moreover, they often exhibit modest sensitivity and hence significantly depend on later result confirmation in central or reference laboratories. The impressive advances observed in recent years in materials sciences and in nanotechnology, as well as in nucleic-acid synthesis and engineering, have led to an outburst of new in-the-bench and prototype tests for nucleic-acid testing towards point-of-care diagnosis of genetic and infectious diseases. Manufacturing, commercial, regulatory, and technical nature issues for field applicability more likely have hindered their wider entrance into veterinary medicine and practice than have fundamental science gaps. This chapter begins by outlining the current situation, requirements, difficulties, and perspectives of point-of-care tests for diagnosing diseases of veterinary interest. Nucleic-acid testing, particularly for the point of care, is addressed subsequently. A range of valuable signal transduction mechanisms commonly employed in proof-of-concept schemes and techniques born on the analytical chemistry laboratories are also described. As the essential core of this chapter, sections dedicated to the principles and applications of microfluidics, lab

  10. Evaluating the efficacy of a chemistry video game

    NASA Astrophysics Data System (ADS)

    Shapiro, Marina

    A quasi-experimental design pre-test/post-test intervention study utilizing a within group analysis was conducted with 45 undergraduate college chemistry students that investigated the effect of implementing a game-based learning environment into an undergraduate college chemistry course in order to learn if serious educational games (SEGs) can be used to achieve knowledge gains of complex chemistry concepts and to achieve increase in students' positive attitude toward chemistry. To evaluate if students learn chemistry concepts by participating in a chemistry game-based learning environment, a one-way repeated measures analysis of variance (ANOVA) was conducted across three time points (pre-test, post-test, delayed post-test which were chemistry content exams). Results showed that there was an increase in exam scores over time. The results of the ANOVA indicated a statistically significant time effect. To evaluate if students' attitude towards chemistry increased as a result of participating in a chemistry game-based learning environment a paired samples t-test was conducted using a chemistry attitudinal survey by Mahdi (2014) as the pre- and post-test. Results of the paired-samples t-test indicated that there was no significant difference in pre-attitudinal scores and post-attitudinal scores.

  11. Point-of-Care Diagnostics in Low-Resource Settings and Their Impact on Care in the Age of the Noncommunicable and Chronic Disease Epidemic.

    PubMed

    Weigl, Bernhard H; Neogi, Tina; McGuire, Helen

    2014-06-01

    The emergence of point-of-care (POC) diagnostics specifically designed for low-resource settings coupled with the rapid increase in need for routine care of patients with chronic diseases should prompt reconsideration of how health care can be delivered most beneficially and cost-effectively in developing countries. Bolstering support for primary care to provide rapid and appropriate integrated acute and chronic care treatment may be a possible solution. POC diagnostics can empower local and primary care providers and enable them to make better clinical decisions. This article explores the opportunity for POC diagnostics to strengthen primary care and chronic disease diagnosis and management in a low-resource setting (LRS) to deliver appropriate, consistent, and integrated care. We analyze the requirements of resource-appropriate chronic disease care, the characteristics of POC diagnostics in LRS versus the developed world, the many roles of diagnostics in the care continuum in LRS, and the process and economics of developing LRS-compatible POC diagnostics. © 2013 Society for Laboratory Automation and Screening.

  12. Determination of the Latent Heats and Triple Point of Perfluorocyclobutane

    ERIC Educational Resources Information Center

    Briggs, A. G.; Strachan, A. N.

    1977-01-01

    Proposes the use of Perfluorocyclobutane in physical chemistry courses to conduct experiments on latent heat, triple point temperatures and pressures, boiling points, and entropy of vaporization. (SL)

  13. The social role of C-reactive protein point-of-care testing to guide antibiotic prescription in Northern Thailand.

    PubMed

    Haenssgen, Marco J; Charoenboon, Nutcha; Althaus, Thomas; Greer, Rachel C; Intralawan, Daranee; Lubell, Yoel

    2018-04-01

    New and affordable point-of-care testing (POCT) solutions are hoped to guide antibiotic prescription and to help limit antimicrobial resistance (AMR)-especially in low- and middle-income countries where resource constraints often prevent extensive diagnostic testing. Anthropological and sociological research has illuminated the role and impact of rapid point-of-care malaria testing. This paper expands our knowledge about the social implications of non-malarial POCT, using the case study of a C-reactive-protein point-of-care testing (CRP POCT) clinical trial with febrile patients at primary-care-level health centres in Chiang Rai province, northern Thailand. We investigate the social role of CRP POCT through its interactions with (a) the healthcare workers who use it, (b) the patients whose routine care is affected by the test, and (c) the existing patient-health system linkages that might resonate or interfere with CRP POCT. We conduct a thematic analysis of data from 58 purposively sampled pre- and post-intervention patients and healthcare workers in August 2016 and May 2017. We find widespread positive attitudes towards the test among patients and healthcare workers. Patients' views are influenced by an understanding of CRP POCT as a comprehensive blood test that provides specific diagnosis and that corresponds to notions of good care. Healthcare workers use the test to support their negotiations with patients but also to legitimise ethical decisions in an increasingly restrictive antibiotic policy environment. We hypothesise that CRP POCT could entail greater patient adherence to recommended antibiotic treatment, but it could also encourage riskier health behaviour and entail potentially adverse equity implications for patients across generations and socioeconomic strata. Our empirical findings inform the clinical literature on increasingly propagated point-of-care biomarker tests to guide antibiotic prescriptions, and we contribute to the anthropological and

  14. Modular microfluidics for point-of-care protein purifications.

    PubMed

    Millet, L J; Lucheon, J D; Standaert, R F; Retterer, S T; Doktycz, M J

    2015-04-21

    Biochemical separations are the heart of diagnostic assays and purification methods for biologics. On-chip miniaturization and modularization of separation procedures will enable the development of customized, portable devices for personalized health-care diagnostics and point-of-use production of treatments. In this report, we describe the design and fabrication of miniature ion exchange, size exclusion and affinity chromatography modules for on-chip clean-up of recombinantly-produced proteins. Our results demonstrate that these common separations techniques can be implemented in microfluidic modules with performance comparable to conventional approaches. We introduce embedded 3-D microfluidic interconnects for integrating micro-scale separation modules that can be arranged and reconfigured to suit a variety of fluidic operations or biochemical processes. We demonstrate the utility of the modular approach with a platform for the enrichment of enhanced green fluorescent protein (eGFP) from Escherichia coli lysate through integrated affinity and size-exclusion chromatography modules.

  15. Point-of-care testing.

    PubMed

    O'Brien, J A

    2000-12-01

    Is POCT worth integrating into a facility? Despite its promise of speed and convenience, this technology requires careful evaluation of potential benefits, disadvantages, and challenges to the existing system. If the pros outweigh the cons, a step-by-step approach can ease the process of implementing a POCT program.

  16. Nine-point plan to improve care of the injured patient: A case study from Kenya.

    PubMed

    Bachani, Abdulgafoor M; Botchey, Isaac; Paruk, Fatima; Wako, Daniel; Saidi, Hassan; Aliwa, Bethuel; Kibias, Simon; Hyder, Adnan A

    2017-12-01

    Injury rates in low- and middle-income countries are among the greatest in the world, with >90% of unintentional injury occurring in low- or middle-income countries. The risk of death from injuries is 6 times more in low- and middle-income countries than in high-income countries. This increased rate of injury is partly due to the lack of availability and access to timely and appropriate medical care for injured individuals. Kenya, like most low- and middle-income countries, has seen a 5-fold increase in injury fatalities throughout the past 4 decades, in large part related to the absence of a coordinated, integrated system of trauma care. We aimed to assess the trauma-care system in Kenya and to develop and implement a plan to improve it. A trauma system profile was performed to understand the landscape for the care of the injured patient in Kenya. This process helped identify key gaps in care ranging from prehospital to hospital-based care. In response to this observation, a 9-point plan to improve trauma care in Kenya was developed and implemented in close collaboration with local stakeholders. The 9-point plan was centered on engagement of the stakeholders, generation of key data to guide and improve services, capacity development for prehospital and hospital care, and strengthening policy and legislation. There is an urgent need for coordinated strategies to provide appropriate and timely medical care to injured individuals in low- or middle-income countries to decrease the burden of injuries and related fatalities. Our work in Kenya shows that such an integrated system of trauma care could be achieved through a step-by-step integrated and multifaceted approach that emphasizes engagement of local stakeholders and evidence-based approaches to ensure effectiveness, efficiency, and sustainability of system-wide improvements. This plan and lessons learned in its development and implementation could be adaptable to other similar settings to improve the care of the

  17. Point-of-Care Testing in Bathhouses: A Narrative Inquiry into the Experience of Receiving a Positive Preliminary HIV Test Result.

    PubMed

    Genoway, Shyla; Caine, Vera; Singh, Ameeta E; Estefan, Andrew

    2016-01-01

    With a call to increase the accessibility of HIV testing, point-of-care testing for HIV is being readily adopted, but little attention has been paid to the experiences of people being tested at HIV point-of-care sites. Some testing environments, such as bathhouses, promote testing for HIV in higher-risk groups. In this narrative inquiry study we explored the experiences of people testing positive for HIV through point-of-care while at a bathhouse. Three narrative threads for reconsidering the practice were identified: (a) seeing complexities, understanding testing decisions in relation to time, place, and social context; (b) recognizing the impact and significance of secret and silent stories; and (c) tentative and tension-filled connections to care. It is important to understand testing experiences across time, place, and in diverse social contexts. These experiences are embedded within the larger life histories of people and raise questions about adequate support, follow-up, and counseling. Copyright © 2016 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  18. Rapid Point-Of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms

    PubMed Central

    Phillips, Michael; Beatty, J. David; Cataneo, Renee N.; Huston, Jan; Kaplan, Peter D.; Lalisang, Roy I.; Lambin, Philippe; Lobbes, Marc B. I.; Mundada, Mayur; Pappas, Nadine; Patel, Urvish

    2014-01-01

    Background Previous studies have reported volatile organic compounds (VOCs) in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands. Methods 244 women had a screening mammogram (93/37 normal/abnormal) or a breast biopsy (cancer/no cancer 35/79). A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air). Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve). Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO) procedure. Results Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO) [C-statistic value], negative predictive value 99.9%); normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO); and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO). Conclusions A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity. PMID:24599224

  19. Leukodepletion as a Point-of-Care Method for Monitoring HIV-1 Viral Load in Whole Blood

    PubMed Central

    Titchmarsh, Logan; Zeh, Clement; Verpoort, Thierry; Allain, Jean-Pierre

    2014-01-01

    In order to limit the interference of HIV-1 cellular nucleic acids in estimating viral load (VL), the feasibility of leukodepletion of a small whole-blood (WB) volume to eliminate only leukocyte cell content was investigated, using a selection of filters. The efficacy of leukocyte filtration was evaluated by counting, CD45 quantitative PCR, and HIV-1 DNA quantification. Plasma HIV-1 was tested by real-time reverse transcription (RT)-PCR. A specific, miniaturized filter was developed and tested for leukocyte and plasma virus retention, WB sample dilution, and filtration parameters in HIV-1-spiked WB samples. This device proved effective to retain >99.9% of white blood cells in 100 μl of WB without affecting plasma VL. The Samba sample preparation chemistry was adapted to use a leukodepleted WB sample for VL monitoring using the point-of-care Samba-1 semiautomated system. The clinical performance of the assay was evaluated by testing 207 consecutive venous EDTA WB samples from HIV-1-infected patients attending a CD4 testing clinic. Most patients were on antiretroviral treatment (ART), but their VL status was unknown. Compared to the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test, the new Samba assay had a concordance of 96.5%. The use of the Samba system with a VL test for WB might contribute to HIV-1 ART management and reduce loss-to-follow-up rates in resource-limited settings. PMID:25428162

  20. Point-of-care technology: integration for improved delivery of care.

    PubMed

    Gregory, Debbie; Buckner, Martha

    2014-01-01

    The growing complexity of technology, equipment, and devices involved in patient care delivery can be staggering and overwhelming. Technology is intended to be a tool to help clinicians, but it can also be a frustrating hindrance if not thoughtfully planned and strategically aligned. Critical care nurses are key partners in the collaborations needed to improve safety and quality through health information technology (IT). Nurses must advocate for systems that are interoperable and adapted to the context of care experiences. The involvement and collaboration between clinicians, information technology specialists, biomedical engineers, and vendors has never been more relevant and applicable. Working together strategically with a shared vision can effectively provide a seamless clinical workflow, maximize technology investments, and ultimately improve patient care delivery and outcomes. Developing a strategic integrated clinical and IT roadmap is a critical component of today's health care environment. How can technology strategy be aligned from the executive suite to the bedside caregiver? What is the model for using clinical workflows to drive technology adoption? How can the voice of the critical care nurse strengthen this process? How can success be assured from the initial assessment and selection of technology to a sustainable support model? What is the vendor's role as a strategic partner and "co-caregiver"?

  1. A clinical perspective on electronically collecting patient-reported outcomes at the point-of-care for overactive bladder

    PubMed Central

    Desantis, Darren; Baverstock, Richard J.; Civitarese, Andrea; Crump, R. Trafford; Carlson, Kevin V.

    2016-01-01

    Introduction Collecting patient-reported outcomes (PROs) can inform the treatment and management of overactive bladder (OAB). However, collecting these data at the point-of-care can be time-consuming and have a negative impact on a clinic’s workflow. The purpose of this study was to pilot a digital system for collecting PROs at the point-of-care and qualitatively assess clinicians’ perspectives in terms of the system’s impact on the delivery of care for OAB. Methods Patients visiting a urology clinic for OAB completed several PRO instruments using a tablet while awaiting assessment. Clinicians reviewed their responses using a digital dashboard during clinical encounters. Qualitative interviews were conducted with the clinicians, to assess the collection system’s impact in terms of: 1) logistics, 2) workflow; 3) patient communication; 4) influence on clinical decisions; 5) user experiences; and 6) the care model. Results Six interviews were conducted and thematic saturation was met, with several themes emerging. All participants were generally positive regarding the use of the digital collecting system. Participants felt that the dashboard improved workflow and enhanced communication with patients, but it was not thought to be any more influential on clinical decision-making than conventional collection methods. Several aspects of the digital PRO collection system were identified as needing improvement. Conclusions The digital PRO collection system used at the point-of-care had a positive impact on the delivery of care for OAB. The results from this study could provide insight to other urologists who are interested in collecting PROs in their clinic. PMID:27942273

  2. Secondary Chemistry School Teachers Working in Tertiary Education Chemistry Departments; Critical Reflections on the Positives and Negatives

    ERIC Educational Resources Information Center

    Glover, S. R.; Harrison, T. G.; Shallcross, D. E.

    2016-01-01

    Several UK University Chemistry Departments have former secondary school chemistry teachers employed as School Teacher Fellows (STF) who are heavily involved in outreach work and a range of teaching responsibilities. This study looks at the outreach role from the point of view of several of the STFs; the benefits, and the barriers and how this…

  3. Fully 3D printed integrated reactor array for point-of-care molecular diagnostics.

    PubMed

    Kadimisetty, Karteek; Song, Jinzhao; Doto, Aoife M; Hwang, Young; Peng, Jing; Mauk, Michael G; Bushman, Frederic D; Gross, Robert; Jarvis, Joseph N; Liu, Changchun

    2018-06-30

    Molecular diagnostics that involve nucleic acid amplification tests (NAATs) are crucial for prevention and treatment of infectious diseases. In this study, we developed a simple, inexpensive, disposable, fully 3D printed microfluidic reactor array that is capable of carrying out extraction, concentration and isothermal amplification of nucleic acids in variety of body fluids. The method allows rapid molecular diagnostic tests for infectious diseases at point of care. A simple leak-proof polymerization strategy was developed to integrate flow-through nucleic acid isolation membranes into microfluidic devices, yielding a multifunctional diagnostic platform. Static coating technology was adopted to improve the biocompatibility of our 3D printed device. We demonstrated the suitability of our device for both end-point colorimetric qualitative detection and real-time fluorescence quantitative detection. We applied our diagnostic device to detection of Plasmodium falciparum in plasma samples and Neisseria meningitides in cerebrospinal fluid (CSF) samples by loop-mediated, isothermal amplification (LAMP) within 50 min. The detection limits were 100 fg for P. falciparum and 50 colony-forming unit (CFU) for N. meningitidis per reaction, which are comparable to that of benchtop instruments. This rapid and inexpensive 3D printed device has great potential for point-of-care molecular diagnosis of infectious disease in resource-limited settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Point of care information services: a platform for self-directed continuing medical education for front line decision makers

    PubMed Central

    Moja, Lorenzo; Kwag, Koren Hyogene

    2015-01-01

    The structure and aim of continuing medical education (CME) is shifting from the passive transmission of knowledge to a competency-based model focused on professional development. Self-directed learning is emerging as the foremost educational method for advancing competency-based CME. In a field marked by the constant expansion of knowledge, self-directed learning allows physicians to tailor their learning strategy to meet the information needs of practice. Point of care information services are innovative tools that provide health professionals with digested evidence at the front line to guide decision making. By mobilising self-directing learning to meet the information needs of clinicians at the bedside, point of care information services represent a promising platform for competency-based CME. Several points, however, must be considered to enhance the accessibility and development of these tools to improve competency-based CME and the quality of care. PMID:25655251

  5. Multiplexed lateral flow biosensors: Technological advances for radically improving point-of-care diagnoses.

    PubMed

    Li, Jia; Macdonald, Joanne

    2016-09-15

    Lateral flow biosensors are a leading technology in point-of-care diagnostics due to their simplicity, rapidness and low cost. Their primacy in this arena continues through technological breakthroughs such as multiplexing: the detection of more than one biomarker in a single assay. Multiplexing capacity is critical for improving diagnostic efficiency, enhancing the diagnostic precision for specific diseases and reducing diagnostic cost. Here we review, for the first time, the various types and strategies employed for creating multiplexed lateral flow biosensors. These are classified into four main categories in terms of specific application or multiplexing level, namely linear, parameter, spatial and conceptual. We describe the practical applications and implications for each approach and compare their advantages and disadvantages. Importantly, multiplexing is still subject to limitations of the traditional lateral flow biosensor, such as sensitivity and specificity. However, by pushing the limitations of the traditional medium into the multiplex arena, several technological breakthroughs are emerging with novel solutions that further expand the utility of lateral flow biosensing for point-of-care applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Awareness, Interest, and Preferences of Primary Care Providers in Using Point-of-Care Cancer Screening Technology.

    PubMed

    Kim, Chloe S; Vanture, Sarah; Cho, Margaret; Klapperich, Catherine M; Wang, Catharine; Huang, Franklin W

    2016-01-01

    Well-developed point-of-care (POC) cancer screening tools have the potential to provide better cancer care to patients in both developed and developing countries. However, new medical technology will not be adopted by medical providers unless it addresses a population's existing needs and end-users' preferences. The goals of our study were to assess primary care providers' level of awareness, interest, and preferences in using POC cancer screening technology in their practice and to provide guidelines to biomedical engineers for future POC technology development. A total of 350 primary care providers completed a one-time self-administered online survey, which took approximately 10 minutes to complete. A $50 Amazon gift card was given as an honorarium for the first 100 respondents to encourage participation. The description of POC cancer screening technology was provided in the beginning of the survey to ensure all participants had a basic understanding of what constitutes POC technology. More than half of the participants (57%) stated that they heard of the term "POC technology" for the first time when they took the survey. However, almost all of the participants (97%) stated they were either "very interested" (68%) or "somewhat interested" (29%) in using POC cancer screening technology in their practice. Demographic characteristics such as the length of being in the practice of medicine, the percentage of patients on Medicaid, and the average number of patients per day were not shown to be associated with the level of interest in using POC. These data show that there is a great interest in POC cancer screening technology utilization among this population of primary care providers and vast room for future investigations to further understand the interest and preferences in using POC cancer technology in practice. Ensuring that the benefits of new technology outweigh the costs will maximize the likelihood it will be used by medical providers and patients.

  7. Cost consequences of point-of-care troponin T testing in a Swedish primary health care setting

    PubMed Central

    Andersson, Agneta; Janzon, Magnus; Karlsson, Jan-Erik; Levin, Lars-Åke

    2014-01-01

    Abstract Objective. To evaluate the safety and cost-effectiveness of point-of-care troponin T testing (POCT-TnT) for the management of patients with chest pain in primary care. Design. Prospective observational study with follow-up. Setting. Three primary health care (PHC) centres using POCT-TnT and four PHC centres not using POCT-TnT in south-east Sweden. Patients. All patients ≥ 35 years of age, contacting one of the PHC centres for chest pain, dyspnoea on exertion, unexplained weakness and/or fatigue, with no other probable cause than cardiac, were included. Symptoms must have commenced or worsened during the previous seven days. Main outcome measures. Emergency referral rates, diagnoses of acute myocardial infarction (AMI) or unstable angina (UA), and costs were collected for 30 days after the patient sought care at the PHC centre. Results. A total of 196 patients with chest pain were included: 128 in PHC centres with POCT-TnT and 68 in PHC centres without POCT-TnT. Fewer patients from the PHC centres with POCT-TnT (n = 32, 25%) were emergently referred to hospital than from centres without POCT-TnT (n = 29, 43%; p = 0.011). Eight patients (6.2%) from PHC centres with POCT-TnT were diagnosed with AMI or UA compared with six patients (8.8%) from centres without POCT-TnT (p = 0.565). Two patients with AMI or UA were classified as missed cases from PHC centres with POCT-TnT and there were no missed cases from PHC centres without POCT-TnT. SKr290 000 was saved per missed case of AMI or UA. Conclusion. The use of POCT-TnT in primary care may be cost saving but at the expense of missed cases. PMID:25434410

  8. Conflict of interest in online point-of-care clinical support websites.

    PubMed

    Amber, Kyle T; Dhiman, Gaurav; Goodman, Kenneth W

    2014-08-01

    Point-of-care evidence-based medicine websites allow physicians to answer clinical queries using recent evidence at the bedside. Despite significant research into the function, usability and effectiveness of these programmes, little attention has been paid to their ethical issues. As many of these sites summarise the literature and provide recommendations, we sought to assess the role of conflicts of interest in two widely used websites: UpToDate and Dynamed. We recorded all conflicts of interest for six articles detailing treatment for the following conditions: erectile dysfunction, fibromyalgia, hypogonadism, psoriasis, rheumatoid arthritis and Crohn's disease. These diseases were chosen as their medical management is either controversial, or they are treated using biological drugs which are mostly available by brand name only. Thus, we hypothesised that the role of conflict of interest would be more significant in these conditions than in an illness treated with generic medications or by strict guidelines. All articles from the UpToDate articles demonstrated a conflict of interest. At times, the editor and author would have a financial relationship with a company whose drug was mentioned within the article. This is in contrast with articles on the Dynamed website, in which no author or editor had a documented conflict. We offer recommendations regarding the role of conflict of interest disclosure in these point-of-care evidence-based medicine websites. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. NIH-IEEE 2015 Strategic Conference on Healthcare Innovations and Point-of-Care Technologies for Prec

    Cancer.gov

    NIH and the Institute for Electrical and Electronics Engineering, Engineering in Medicine and Biology Society (IEEE/EMBS) hosted the third iteration of the Healthcare Innovations and Point-of-Care Technologies Conference last week.

  10. Use of point-of-care ultrasound to evaluate for penile fracture in a child.

    PubMed

    Lam, Samuel H F

    2015-02-01

    Penile fracture is a urologic emergency requiring prompt surgical intervention. Ultrasound may help clarify the diagnosis in cases of uncertain history and physical examination. The author presents a case of suspected pediatric penile fracture, in which point-of-care ultrasound helped to rule out the condition and facilitated disposition of the patient.

  11. Modular microfluidics for point-of-care protein purifications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Millet, L. J.; Lucheon, J. D.; Standaert, R. F.

    Biochemical separations are the heart of diagnostic assays and purification methods for biologics. On-chip miniaturization and modularization of separation procedures will enable the development of customized, portable devices for personalized health-care diagnostics and point-of-use production of treatments. In this report, we describe the design and fabrication of miniature ion exchange, size exclusion and affinity chromatography modules for on-chip clean-up of recombinantly-produced proteins. Our results demonstrate that these common separations techniques can be implemented in microfluidic modules with performance comparable to conventional approaches. We introduce embedded 3-D microfluidic interconnects for integrating micro-scale separation modules that can be arranged and reconfigured tomore » suit a variety of fluidic operations or biochemical processes. In conclusion, we demonstrate the utility of the modular approach with a platform for the enrichment of enhanced green fluorescent protein (eGFP) from Escherichia coli lysate through integrated affinity and size-exclusion chromatography modules.« less

  12. Modular microfluidics for point-of-care protein purifications

    DOE PAGES

    Millet, L. J.; Lucheon, J. D.; Standaert, R. F.; ...

    2015-01-01

    Biochemical separations are the heart of diagnostic assays and purification methods for biologics. On-chip miniaturization and modularization of separation procedures will enable the development of customized, portable devices for personalized health-care diagnostics and point-of-use production of treatments. In this report, we describe the design and fabrication of miniature ion exchange, size exclusion and affinity chromatography modules for on-chip clean-up of recombinantly-produced proteins. Our results demonstrate that these common separations techniques can be implemented in microfluidic modules with performance comparable to conventional approaches. We introduce embedded 3-D microfluidic interconnects for integrating micro-scale separation modules that can be arranged and reconfigured tomore » suit a variety of fluidic operations or biochemical processes. In conclusion, we demonstrate the utility of the modular approach with a platform for the enrichment of enhanced green fluorescent protein (eGFP) from Escherichia coli lysate through integrated affinity and size-exclusion chromatography modules.« less

  13. Point-of-Care Coagulation Monitoring in Trauma Patients.

    PubMed

    Stein, Philipp; Kaserer, Alexander; Spahn, Gabriela H; Spahn, Donat R

    2017-06-01

    Trauma remains one of the major causes of death and disability all over the world. Uncontrolled blood loss and trauma-induced coagulopathy represent preventable causes of trauma-related morbidity and mortality. Treatment may consist of allogeneic blood product transfusion at a fixed ratio or in an individualized goal-directed way based on point-of-care (POC) and routine laboratory measurements. Viscoelastic POC measurement of the developing clot in whole blood and POC platelet function testing allow rapid and tailored coagulation and transfusion treatment based on goal-directed, factor concentrate-based algorithms. The first studies have been published showing that this concept reduces the need for allogeneic blood transfusion and improves outcome. This review highlights the concept of goal-directed POC coagulation management in trauma patients, introduces a selection of POC devices, and presents algorithms which allow a reduction in allogeneic blood product transfusion and an improvement of trauma patient outcome. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Answering questions at the point of care: do residents practice EBM or manage information sources?

    PubMed

    McCord, Gary; Smucker, William D; Selius, Brian A; Hannan, Scott; Davidson, Elliot; Schrop, Susan Labuda; Rao, Vinod; Albrecht, Paula

    2007-03-01

    To determine the types of information sources that evidence-based medicine (EBM)-trained, family medicine residents use to answer clinical questions at the point of care, to assess whether the sources are evidence-based, and to provide suggestions for more effective information-management strategies in residency training. In 2005, trained medical students directly observed (for two half-days per physician) how 25 third-year family medicine residents retrieved information to answer clinical questions arising at the point of care and documented the type and name of each source, the retrieval location, and the estimated time spent consulting the source. An end-of-study questionnaire asked 37 full-time faculty and the participating residents about the best information sources available, subscriptions owned, why they use a personal digital assistant (PDA) to practice medicine, and their experience in preventing medical errors using a PDA. Forty-four percent of questions were answered by attending physicians, 23% by consulting PDAs, and 20% from books. Seventy-two percent of questions were answered within two minutes. Residents rated UptoDate as the best source for evidence-based information, but they used this source only five times. PDAs were used because of ease of use, time factors, and accessibility. All examples of medical errors discovered or prevented with PDA programs were medication related. None of the participants' residencies required the use of a specific medical information resource. The results support the Agency for Health Care Research and Quality's call for medical system improvements at the point of care. Additionally, it may be necessary to teach residents better information-management skills in addition to EBM skills.

  15. The Accuracy of Point-of-Care Glucose Measurements

    PubMed Central

    Rebel, Annette; Rice, Mark A.; Fahy, Brenda G.

    2012-01-01

    Control of blood glucose (BG) in an acceptable range is a major therapy target for diabetes patients in both the hospital and outpatient environments. This review focuses on the state of point-of-care (POC) glucose monitoring and the accuracy of the measurement devices. The accuracy of the POC glucose monitor depends on device methodology and other factors, including sample source and collection and patient characteristics. Patient parameters capable of influencing measurements include variations in pH, blood oxygen, hematocrit, changes in microcirculation, and vasopressor therapy. These elements alone or when combined can significantly impact BG measurement accuracy with POC glucose monitoring devices (POCGMDs). In general, currently available POCGMDs exhibit the greatest accuracy within the range of physiological glucose levels but become less reliable at the lower and higher ranges of BG levels. This issue raises serious safety concerns and the importance of understanding the limitations of POCGMDs. This review will discuss potential interferences and shortcomings of the current POCGMDs and stress when these may impact the reliability of POCGMDs for clinical decision-making. PMID:22538154

  16. Self-priming compartmentalization digital LAMP for point-of-care.

    PubMed

    Zhu, Qiangyuan; Gao, Yibo; Yu, Bingwen; Ren, Hao; Qiu, Lin; Han, Sihai; Jin, Wei; Jin, Qinhan; Mu, Ying

    2012-11-21

    useful for point-of-care, and enabling it to become one of the common tools for biology research, especially, in point-of-care testing.

  17. Product qualification: a barrier to point-of-care microfluidic-based diagnostics?

    PubMed

    Tantra, Ratna; van Heeren, Henne

    2013-06-21

    One of the most exciting applications of microfluidics-based diagnostics is its potential use in next generation point-of-care (POC) devices. Many prototypes are already in existence, but, as of yet, few have achieved commercialisation. In this article, we consider the issue surrounding product qualification as a potential barrier to market success. The study discusses, in the context of POC microfluidics-based diagnostics, what the generic issues are and potential solutions. Our findings underline the need for a community-based effort that is necessary to speed up the product qualification process.

  18. International definition of a point-of-care test in family practice: a modified e-Delphi procedure.

    PubMed

    Schols, Angel M R; Dinant, Geert-Jan; Hopstaken, Rogier; Price, Christopher P; Kusters, Ron; Cals, Jochen W L

    2018-01-29

    The use of point-of-care tests (POCTs) in family practice is increasing, and the term POCT is often used in medical literature and clinical practice. Yet, no widely supported definition by several professional fields exists. To reach consensus on an international definition of a POCT in family practice. We performed a modified international e-Delphi procedure of four rounds among expert panel members from different professional backgrounds-family practitioners, laboratory specialists, policymakers, researchers and manufacturers. Of 27 panel members from seven different countries, 26 participated in all rounds. Most panel members were active in POCT research or policymaking and 70% worked in family medicine. After choosing important components, structuring of answers and feedback, the following definition was chosen as the best or second best definition by 81% of panel members: a point-of-care test in family practice is a test to support clinical decision making, which is performed by a qualified member of the practice staff nearby the patient and on any part of the patient's body or its derivatives, during or very close to the time of consultation, to help the patient and physician to decide upon the best suited approach, and of which the results should be known at the time of the clinical decision making. The definition emerging from this study can inform family practitioners, laboratory specialists, policymakers and manufacturers on the most widely supported and recognized definition and could act as a clear starting point for the organization and execution of professional point-of-care testing in family practice worldwide. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. An Investigation of College Chemistry Students' Understanding of Structure-Property Relationships

    ERIC Educational Resources Information Center

    Cooper, Melanie M.; Corley, Leah M.; Underwood, Sonia M.

    2013-01-01

    The connection between the molecular-level structure of a substance and its macroscopic properties is a fundamental concept in chemistry. Students in college-level general and organic chemistry courses were interviewed to investigate how they used structure-property relationships to predict properties such as melting and boiling points. Although…

  20. What's Difficult about Chemistry? An Irish Perspective

    ERIC Educational Resources Information Center

    Childs, Peter E.; Sheehan, Maria

    2009-01-01

    This semi-longitudinal investigation identified the chemistry topics that the majority of Irish chemistry pupils/students find difficult, from Junior Certificate level (age 15/16 years) right the way through to University level (age 18+). Pupils/students completed a five point, Likert-type questionnaire listing the topics covered in the different…

  1. Cardiac Point-of-Care Ultrasound: State of the Art in Medical School Education.

    PubMed

    Johri, Amer M; Durbin, Joshua; Newbigging, Joseph; Tanzola, Robert; Chow, Ryan; De, Sabe; Tam, James

    2018-03-14

    The development of small, user friendly, handheld ultrasound devices has stimulated the growth of cardiac point-of-care ultrasound (POCUS) for the purpose of rapid, bedside cardiac assessment. Medical schools have begun integrating cardiac POCUS into their curricula. In this review the authors summarize the variable approaches taken by several medical training programs with respect to duration of POCUS training, prerequisite knowledge, and methods of delivering these skills (including e-learning, hands-on training, and simulation). The authors also address issues related to the need for competency evaluation and the limitations of the technology itself. The studies reviewed suggest that undergraduate education is a viable point at which to introduce basic POCUS concepts. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  2. Electronic health record interventions at the point of care improve documentation of care processes and decrease orders for genetic tests commonly ordered by nongeneticists.

    PubMed

    Scheuner, Maren T; Peredo, Jane; Tangney, Kelly; Schoeff, Diane; Sale, Taylor; Lubick-Goldzweig, Caroline; Hamilton, Alison; Hilborne, Lee; Lee, Martin; Mittman, Brian; Yano, Elizabeth M; Lubin, Ira M

    2017-01-01

    To determine whether electronic health record (EHR) tools improve documentation of pre- and postanalytic care processes for genetic tests ordered by nongeneticists. We conducted a nonrandomized, controlled, pre-/postintervention study of EHR point-of-care tools (informational messages and template report) for three genetic tests. Chart review assessed documentation of genetic testing processes of care, with points assigned for each documented item. Multiple linear and logistic regressions assessed factors associated with documentation. Preimplementation, there were no significant site differences (P > 0.05). Postimplementation, mean documentation scores increased (5.9 (2.1) vs. 5.0 (2.2); P = 0.0001) and records with clinically meaningful documentation increased (score >5: 59 vs. 47%; P = 0.02) at the intervention versus the control site. Pre- and postimplementation, a score >5 was positively associated with abnormal test results (OR = 4.0; 95% CI: 1.8-9.2) and trainee provider (OR = 2.3; 95% CI: 1.2-4.6). Postimplementation, a score >5 was also positively associated with intervention site (OR = 2.3; 95% CI: 1.1-5.1) and specialty clinic (OR = 2.0; 95% CI: 1.1-3.6). There were also significantly fewer tests ordered after implementation (264/100,000 vs. 204/100,000; P = 0.03), with no significant change at the control site (280/100,000 vs. 257/100,000; P = 0.50). EHR point-of-care tools improved documentation of genetic testing processes and decreased utilization of genetic tests commonly ordered by nongeneticists.Genet Med 19 1, 112-120.

  3. Impact of HbA1c Testing at Point of Care on Diabetes Management

    PubMed Central

    Schnell, Oliver; Crocker, J. Benjamin; Weng, Jianping

    2016-01-01

    Diabetes is a highly prevalent disease also implicated in the development of several other serious complications like cardiovascular or renal disease. HbA1c testing is a vital step for effective diabetes management, however, given the low compliance to testing frequency and, commonly, a subsequent delay in the corresponding treatment modification, HbA1c at the point of care (POC) offers an opportunity for improvement of diabetes care. In this review, based on data from 1999 to 2016, we summarize the evidence supporting a further implementation of HbA1c testing at POC, discuss its limitations and propose recommendations for further development. PMID:27898388

  4. Efficacy of adrenal venous sampling is increased by point of care cortisol analysis

    PubMed Central

    Viste, Kristin; Grytaas, Marianne A; Jørstad, Melissa D; Jøssang, Dag E; Høyden, Eivind N; Fotland, Solveig S; Jensen, Dag K; Løvås, Kristian; Thordarson, Hrafnkell; Almås, Bjørg; Mellgren, Gunnar

    2013-01-01

    Primary aldosteronism (PA) is a common cause of secondary hypertension and is caused by unilateral or bilateral adrenal disease. Treatment options depend on whether the disease is lateralized or not, which is preferably evaluated with selective adrenal venous sampling (AVS). This procedure is technically challenging, and obtaining representative samples from the adrenal veins can prove difficult. Unsuccessful AVS procedures often require reexamination. Analysis of cortisol during the procedure may enhance the success rate. We invited 21 consecutive patients to participate in a study with intra-procedural point of care cortisol analysis. When this assay showed nonrepresentative sampling, new samples were drawn after redirection of the catheter. The study patients were compared using the 21 previous procedures. The intra-procedural cortisol assay increased the success rate from 10/21 patients in the historical cohort to 17/21 patients in the study group. In four of the 17 successful procedures, repeated samples needed to be drawn. Successful sampling at first attempt improved from the first seven to the last seven study patients. Point of care cortisol analysis during AVS improves success rate and reduces the need for reexaminations, in accordance with previous studies. Successful AVS is crucial when deciding which patients with PA will benefit from surgical treatment. PMID:24169597

  5. Evaluation of new indigenous "point-of-care" ABO and Rh grouping device.

    PubMed

    Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad

    2018-01-01

    Erycard 2.0 is a "point-of-care" device that is primarily being used for patient blood grouping before transfusion. Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. Erycard 2.0 can be used as "point-of-care" device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique.

  6. The Role of Affordable, Point-of-Care Technologies for Cancer Care in Low- and Middle-Income Countries: A Review and Commentary.

    PubMed

    Haney, Karen; Tandon, Pushpa; Divi, Rao; Ossandon, Miguel R; Baker, Houston; Pearlman, Paul C

    2017-01-01

    As the burden of non-communicable diseases such as cancer continues to rise in low- and middle-income countries (LMICs), it is essential to identify and invest in promising solutions for cancer control and treatment. Point-of-care technologies (POCTs) have played critical roles in curbing infectious disease epidemics in both high- and low-income settings, and their successes can serve as a model for transforming cancer care in LMICs, where access to traditional clinical resources is often limited. The versatility, cost-effectiveness, and simplicity of POCTs warrant attention for their potential to revolutionize cancer detection, diagnosis, and treatment. This paper reviews the landscape of affordable POCTs for cancer care in LMICs with a focus on imaging tools, in vitro diagnostics, and treatment technologies and aspires to encourage innovation and further investment in this space.

  7. 3D Printing and Assay Development for Point-of-Care Applications

    NASA Astrophysics Data System (ADS)

    Jagadeesh, Shreesha

    Existing centralized labs do not serve patients adequately in remote areas. To enable universal timely healthcare, there is a need to develop low cost, portable systems that can diagnose multiple disease (Point-of-Care (POC) devices). Future POC diagnostics can be more multi-functional if medical device vendors can develop interoperability standards. This thesis developed the following medical diagnostic modules: Plasma from 25 microl blood was extracted through a filter membrane to demonstrate a 3D printed sample preparation module. Sepsis biomarker, C - reactive protein, was quantified through adsorption on nylon beads to demonstrate bead-based assay suitable for 3D printed disposable cartridge module. Finally, a modular fluorescent detection kit was built using 3D printed parts to detect CD4 cells in a disposable cartridge from ChipCare Corp. Due to the modularity enabled by 3D printing technique, the developed units can be easily adapted to detect other diseases.

  8. Economic evaluations of point of care testing strategies for active tuberculosis.

    PubMed

    Zwerling, Alice; Dowdy, David

    2013-06-01

    Point of care (POC) diagnostics are often hailed as having the potential to transform tuberculosis (TB) control efforts. However, POC testing is better conceptualized as a system of diagnosis and treatment, not simply a test that can provide rapid, deployable results. Economic evaluations may help decision makers allocate scarce resources for TB control, but evaluations of POC testing face unique challenges that include evaluating the full diagnostic system, incorporating implementation costs, translating diagnostic results into health and accounting for downstream treatment costs. For economic evaluations to reach their full potential as decision-making tools for POC testing in TB, these challenges must be understood and addressed.

  9. Metacognitive factors that impact student nurse use of point of care technology in clinical settings.

    PubMed

    Kuiper, RuthAnne

    2010-01-01

    The utility of personal digital assistants (PDA) as a point of care resource in health care practice and education presents new challenges for nursing faculty. While there is a plethora of PDA resources available, little is known about the variables that effect student learning and technology adoption. In this study nursing students used PDA software programs which included a drug guide, medical dictionary, laboratory manual and nursing diagnosis manual during acute care clinical experiences. Analysis of student journals comparative reflective statements about the PDA as an adjunct to other available resources in clinical practice are presented. The benefits of having a PDA included readily available data, validation of thinking processes, and facilitation of care plan re-evaluation. Students reported increased frequency of use and independence. Significant correlations between user perceptions and computer self-efficacy suggested greater confidence in abilities with technology resulting in increased self-awareness and achievement of learning outcomes.

  10. Optical biosensor technologies for molecular diagnostics at the point-of-care

    NASA Astrophysics Data System (ADS)

    Schotter, Joerg; Schrittwieser, Stefan; Muellner, Paul; Melnik, Eva; Hainberger, Rainer; Koppitsch, Guenther; Schrank, Franz; Soulantika, Katerina; Lentijo-Mozo, Sergio; Pelaz, Beatriz; Parak, Wolfgang; Ludwig, Frank; Dieckhoff, Jan

    2015-05-01

    Label-free optical schemes for molecular biosensing hold a strong promise for point-of-care applications in medical research and diagnostics. Apart from diagnostic requirements in terms of sensitivity, specificity, and multiplexing capability, also other aspects such as ease of use and manufacturability have to be considered in order to pave the way to a practical implementation. We present integrated optical waveguide as well as magnetic nanoparticle based molecular biosensor concepts that address these aspects. The integrated optical waveguide devices are based on low-loss photonic wires made of silicon nitride deposited by a CMOS compatible plasma-enhanced chemical vapor deposition (PECVD) process that allows for backend integration of waveguides on optoelectronic CMOS chips. The molecular detection principle relies on evanescent wave sensing in the 0.85 μm wavelength regime by means of Mach-Zehnder interferometers, which enables on-chip integration of silicon photodiodes and, thus, the realization of system-on-chip solutions. Our nanoparticle-based approach is based on optical observation of the dynamic response of functionalized magneticcore/ noble-metal-shell nanorods (`nanoprobes') to an externally applied time-varying magnetic field. As target molecules specifically bind to the surface of the nanoprobes, the observed dynamics of the nanoprobes changes, and the concentration of target molecules in the sample solution can be quantified. This approach is suitable for dynamic real-time measurements and only requires minimal sample preparation, thus presenting a highly promising point-of-care diagnostic system. In this paper, we present a prototype of a diagnostic device suitable for highly automated sample analysis by our nanoparticle-based approach.

  11. Effectiveness of surface enhanced Raman spectroscopy of tear fluid with soft substrate for point-of-care therapeutic drug monitoring

    NASA Astrophysics Data System (ADS)

    Yamada, K.; Endo, T.; Imai, H.; Kido, M.; Jeong, H.; Ohno, Y.

    2016-03-01

    We have developed the point-of-care therapeutic drug monitoring kit based on Raman Spectroscopy of tear fluid. In this study, we were examined a soft substrate for an optimal lattice based on nanoimprint lithography using cyclo-olefin polymer to improve the sensitivity for measuring drug concentration in tear fluid. This is photonics crystal which is one of the nano-photonics based device was fabricated. Target is Sodium Phenobarbital which is an anticonvulsant agent. We show the effectiveness of Surface Enhanced Raman Spectroscopy of tear fluid with soft substrate for point-of-care therapeutic drug monitoring.

  12. "I Do Feel Like a Scientist at Times": A Qualitative Study of the Acceptability of Molecular Point-Of-Care Testing for Chlamydia and Gonorrhoea to Primary Care Professionals in a Remote High STI Burden Setting.

    PubMed

    Natoli, Lisa; Guy, Rebecca J; Shephard, Mark; Causer, Louise; Badman, Steven G; Hengel, Belinda; Tangey, Annie; Ward, James; Coburn, Tony; Anderson, David; Kaldor, John; Maher, Lisa

    2015-01-01

    Point-of-care tests for chlamydia (CT) and gonorrhoea (NG) could increase the uptake and timeliness of testing and treatment, contribute to improved disease control and reduce reproductive morbidity. The GeneXpert (Xpert CT/NG assay), suited to use at the point-of-care, is being used in the TTANGO randomised controlled trial (RCT) in 12 remote Australian health services with a high burden of sexually transmissible infections (STIs). This represents the first ever routine use of a molecular point-of-care diagnostic for STIs in primary care. The purpose of this study was to explore the acceptability of the GeneXpert to primary care staff in remote Australia. In-depth qualitative interviews were conducted with 16 staff (registered or enrolled nurses and Aboriginal Health Workers/Practitioners) trained and experienced with GeneXpert testing. Interviews were digitally-recorded and transcribed verbatim prior to content analysis. Most participants displayed positive attitudes, indicating the test was both easy to use and useful in their clinical context. Participants indicated that point-of-care testing had improved management of STIs, resulting in more timely and targeted treatment, earlier commencement of partner notification, and reduced follow up efforts associated with client recall. Staff expressed confidence in point-of-care test results and treating patients on this basis, and reported greater job satisfaction. While point-of-care testing did not negatively impact on client flow, several found the manual documentation processes time consuming, suggesting that improved electronic connectivity and test result transfer between the GeneXpert and patient management systems could overcome this. Managing positive test results in a shorter time frame was challenging for some but most found it satisfying to complete episodes of care more quickly. In the context of a RCT, health professionals working in remote primary care in Australia found the GeneXpert highly acceptable

  13. Systematic Diabetes Screening Using Point-of-Care HbA1c Testing Facilitates Identification of Prediabetes.

    PubMed

    Whitley, Heather P; Hanson, Courtney; Parton, Jason M

    2017-03-01

    This prospective longitudinal study compares diabetes screenings between standard practices vs systematically offered point-of-care (POC) hemoglobin A 1c (HbA 1c ) tests in patients aged 45 years or older. Systematically screened participants (n = 164) identified 63% (n = 104) with unknown hyperglycemia and 53% (n = 88) in prediabetes. The standard practice (n = 324) screened 22% (n = 73), most commonly by blood glucose (96%); 8% (n = 6) and 33% (n = 24) were found to have diabetes and prediabetes, respectively. The association between screening outcome and screening method was statistically significant ( P = 0.005) in favor of HbA 1C HbA 1c may be the most effective method to identify patients unknowingly living in hyperglycemia. Point-of-care tests further facilitate screening evaluation in a timely and feasible fashion. © 2017 Annals of Family Medicine, Inc.

  14. Infectious Disease Management through Point-of-Care Personalized Medicine Molecular Diagnostic Technologies

    PubMed Central

    Bissonnette, Luc; Bergeron, Michel G.

    2012-01-01

    Infectious disease management essentially consists in identifying the microbial cause(s) of an infection, initiating if necessary antimicrobial therapy against microbes, and controlling host reactions to infection. In clinical microbiology, the turnaround time of the diagnostic cycle (>24 hours) often leads to unnecessary suffering and deaths; approaches to relieve this burden include rapid diagnostic procedures and more efficient transmission or interpretation of molecular microbiology results. Although rapid nucleic acid-based diagnostic testing has demonstrated that it can impact on the transmission of hospital-acquired infections, we believe that such life-saving procedures should be performed closer to the patient, in dedicated 24/7 laboratories of healthcare institutions, or ideally at point of care. While personalized medicine generally aims at interrogating the genomic information of a patient, drug metabolism polymorphisms, for example, to guide drug choice and dosage, personalized medicine concepts are applicable in infectious diseases for the (rapid) identification of a disease-causing microbe and determination of its antimicrobial resistance profile, to guide an appropriate antimicrobial treatment for the proper management of the patient. The implementation of point-of-care testing for infectious diseases will require acceptance by medical authorities, new technological and communication platforms, as well as reimbursement practices such that time- and life-saving procedures become available to the largest number of patients. PMID:25562799

  15. Point-of-care technologies for molecular diagnostics using a drop of blood.

    PubMed

    Song, Yujun; Huang, Yu-Yen; Liu, Xuewu; Zhang, Xiaojing; Ferrari, Mauro; Qin, Lidong

    2014-03-01

    Molecular diagnostics is crucial for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor and time intensive, expensive, and require highly trained operators. This review discusses the frontiers of point-of-care (POC) diagnostic technologies using a drop of blood obtained from a finger prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Awareness, Interest, and Preferences of Primary Care Providers in Using Point-of-Care Cancer Screening Technology

    PubMed Central

    Kim, Chloe S.; Vanture, Sarah; Cho, Margaret; Klapperich, Catherine M.; Wang, Catharine; Huang, Franklin W.

    2016-01-01

    Well-developed point-of-care (POC) cancer screening tools have the potential to provide better cancer care to patients in both developed and developing countries. However, new medical technology will not be adopted by medical providers unless it addresses a population’s existing needs and end-users’ preferences. The goals of our study were to assess primary care providers’ level of awareness, interest, and preferences in using POC cancer screening technology in their practice and to provide guidelines to biomedical engineers for future POC technology development. A total of 350 primary care providers completed a one-time self-administered online survey, which took approximately 10 minutes to complete. A $50 Amazon gift card was given as an honorarium for the first 100 respondents to encourage participation. The description of POC cancer screening technology was provided in the beginning of the survey to ensure all participants had a basic understanding of what constitutes POC technology. More than half of the participants (57%) stated that they heard of the term “POC technology” for the first time when they took the survey. However, almost all of the participants (97%) stated they were either “very interested” (68%) or “somewhat interested” (29%) in using POC cancer screening technology in their practice. Demographic characteristics such as the length of being in the practice of medicine, the percentage of patients on Medicaid, and the average number of patients per day were not shown to be associated with the level of interest in using POC. These data show that there is a great interest in POC cancer screening technology utilization among this population of primary care providers and vast room for future investigations to further understand the interest and preferences in using POC cancer technology in practice. Ensuring that the benefits of new technology outweigh the costs will maximize the likelihood it will be used by medical providers and

  17. Collection Development: Celebrating Chemistry, February 1, 2011

    ERIC Educational Resources Information Center

    Hamm, Susannah

    2011-01-01

    A hundred years after Marie Curie received her Nobel Prize in Chemistry, this arm of science is pointing the way to a more sustainable future. Growing movements like green chemistry, which strives to create alternative and new chemical reactions that produce no harmful waste products, and molecular engineering hold great potential for industry,…

  18. Portable point-of-care blood analysis system for global health (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Dou, James J.; Aitchison, James Stewart; Chen, Lu; Nayyar, Rakesh

    2016-03-01

    In this paper we present a portable blood analysis system based on a disposable cartridge and hand-held reader. The platform can perform all the sample preparation, detection and waste collection required to complete a clinical test. In order to demonstrate the utility of this approach a CD4 T cell enumeration was carried out. A handheld, point-of-care CD4 T cell system was developed based on this system. In particular we will describe a pneumatic, active pumping method to control the on-chip fluidic actuation. Reagents for the CD4 T cell counting assay were dried on a reagent plug to eliminate the need for cold chain storage when used in the field. A micromixer based on the active fluidic actuation was designed to complete sample staining with fluorescent dyes that was dried on the reagent plugs. A novel image detection and analysis algorithm was developed to detect and track the flight of target particles and cells during each analysis. The handheld, point-of-care CD4 testing system was benchmarked against clinical cytometer. The experimental results demonstrated experimental results were closely matched with the flow cytometry. The same platform can be further expanded into a bead-array detection system where other types of biomolecules such as proteins can be detected using the same detection system.

  19. Usability Evaluation at the Point-of-Care: A Method to Identify User Information Needs in CPOE Applications

    PubMed Central

    Washburn, Jeff; Fiol, Guilherme Del; Rocha, Roberto A.

    2006-01-01

    Point of care usability evaluation may help identify information needs that occur during the process of providing care. We describe the process of using usability-specific recording software to record Computerized Physician Order Entry (CPOE) ordering sessions on admitted adult and pediatric patients at two urban tertiary hospitals in the Intermountain Healthcare system of hospitals. PMID:17238756

  20. Providing Doctors With High-Quality Information: An Updated Evaluation of Web-Based Point-of-Care Information Summaries.

    PubMed

    Kwag, Koren Hyogene; González-Lorenzo, Marien; Banzi, Rita; Bonovas, Stefanos; Moja, Lorenzo

    2016-01-19

    The complexity of modern practice requires health professionals to be active information-seekers. Our aim was to review the quality and progress of point-of-care information summaries-Web-based medical compendia that are specifically designed to deliver pre-digested, rapidly accessible, comprehensive, and periodically updated information to health care providers. We aimed to evaluate product claims of being evidence-based. We updated our previous evaluations by searching Medline, Google, librarian association websites, and conference proceedings from August 2012 to December 2014. We included Web-based, regularly updated point-of-care information summaries with claims of being evidence-based. We extracted data on the general characteristics and content presentation of products, and we quantitatively assessed their breadth of disease coverage, editorial quality, and evidence-based methodology. We assessed potential relationships between these dimensions and compared them with our 2008 assessment. We screened 58 products; 26 met our inclusion criteria. Nearly a quarter (6/26, 23%) were newly identified in 2014. We accessed and analyzed 23 products for content presentation and quantitative dimensions. Most summaries were developed by major publishers in the United States and the United Kingdom; no products derived from low- and middle-income countries. The main target audience remained physicians, although nurses and physiotherapists were increasingly represented. Best Practice, Dynamed, and UptoDate scored the highest across all dimensions. The majority of products did not excel across all dimensions: we found only a moderate positive correlation between editorial quality and evidence-based methodology (r=.41, P=.0496). However, all dimensions improved from 2008: editorial quality (P=.01), evidence-based methodology (P=.015), and volume of diseases and medical conditions (P<.001). Medical and scientific publishers are investing substantial resources towards the

  1. Providing Doctors With High-Quality Information: An Updated Evaluation of Web-Based Point-of-Care Information Summaries

    PubMed Central

    Kwag, Koren Hyogene; González-Lorenzo, Marien; Banzi, Rita; Bonovas, Stefanos

    2016-01-01

    Background The complexity of modern practice requires health professionals to be active information-seekers. Objective Our aim was to review the quality and progress of point-of-care information summaries—Web-based medical compendia that are specifically designed to deliver pre-digested, rapidly accessible, comprehensive, and periodically updated information to health care providers. We aimed to evaluate product claims of being evidence-based. Methods We updated our previous evaluations by searching Medline, Google, librarian association websites, and conference proceedings from August 2012 to December 2014. We included Web-based, regularly updated point-of-care information summaries with claims of being evidence-based. We extracted data on the general characteristics and content presentation of products, and we quantitatively assessed their breadth of disease coverage, editorial quality, and evidence-based methodology. We assessed potential relationships between these dimensions and compared them with our 2008 assessment. Results We screened 58 products; 26 met our inclusion criteria. Nearly a quarter (6/26, 23%) were newly identified in 2014. We accessed and analyzed 23 products for content presentation and quantitative dimensions. Most summaries were developed by major publishers in the United States and the United Kingdom; no products derived from low- and middle-income countries. The main target audience remained physicians, although nurses and physiotherapists were increasingly represented. Best Practice, Dynamed, and UptoDate scored the highest across all dimensions. The majority of products did not excel across all dimensions: we found only a moderate positive correlation between editorial quality and evidence-based methodology (r=.41, P=.0496). However, all dimensions improved from 2008: editorial quality (P=.01), evidence-based methodology (P=.015), and volume of diseases and medical conditions (P<.001). Conclusions Medical and scientific publishers are

  2. Clinicians' interpretations of point of care urine culture versus laboratory culture results: analysis from the four-country POETIC trial of diagnosis of uncomplicated urinary tract infection in primary care.

    PubMed

    Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J M; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C

    2017-08-01

    Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care. To identify the degree to which clinicians' interpretations of a point-of-care-test (POCT) urine culture (Flexicult™ SSI-Urinary Kit) agrees with laboratory culture in women presenting to primary care with symptoms of uncomplicated urinary tract infections (UTI). Primary care clinicians used the Flexicult™-POCT, recorded their findings and took a photograph of the result, which was interpreted by microbiology laboratory technicians. Urine samples were additionally processed in routine care laboratories. Cross tabulations were used to identify important differences in organism identification, quantification and antibiotic susceptibility between these three sources of data. The influence of various laboratory definitions for UTI on culture were assessed. Primary care clinicians identified 202/289 urine samples (69.9%) as positive for UTI using the Flexicult™-POCT, whereas laboratory culture identified 94-190 (32.5-65.7%) as positive, depending on definition thresholds. 82.9% of samples identified positive for E. coli on laboratory culture were also considered positive for E. coli using the Flexicult™ -POCT, and susceptibilities were reasonably concordant. There were major discrepancies between laboratory staff interpretation of Flexicult™ photographs, clinicians' interpretation of the Flexicult™ test, and laboratory culture results. Flexicult™-POCT overestimated the positivity rate of urine samples for UTI when laboratory culture was used as the reference standard. However, it is unclear whether point-of-care or laboratory based urine culture provides the most valid diagnostic information. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Lab-on-a-chip nucleic-acid analysis towards point-of-care applications

    NASA Astrophysics Data System (ADS)

    Kopparthy, Varun Lingaiah

    Recent infectious disease outbreaks, such as Ebola in 2013, highlight the need for fast and accurate diagnostic tools to combat the global spread of the disease. Detection and identification of the disease-causing viruses and bacteria at the genetic level is required for accurate diagnosis of the disease. Nucleic acid analysis systems have shown promise in identifying diseases such as HIV, anthrax, and Ebola in the past. Conventional nucleic acid analysis systems are still time consuming, and are not suitable for point-ofcare applications. Miniaturized nucleic acid systems has shown great promise for rapid analysis, but they have not been commercialized due to several factors such as footprint, complexity, portability, and power consumption. This dissertation presents the development of technologies and methods for a labon-a-chip nucleic acid analysis towards point-of-care applications. An oscillatory-flow PCR methodology in a thermal gradient is developed which provides real-time analysis of nucleic-acid samples. Oscillating flow PCR was performed in the microfluidic device under thermal gradient in 40 minutes. Reverse transcription PCR (RT-PCR) was achieved in the system without an additional heating element for incubation to perform reverse transcription step. A novel method is developed for the simultaneous pattering and bonding of all-glass microfluidic devices in a microwave oven. Glass microfluidic devices were fabricated in less than 4 minutes. Towards an integrated system for the detection of amplified products, a thermal sensing method is studied for the optimization of the sensor output. Calorimetric sensing method is characterized to identify design considerations and optimal parameters such as placement of the sensor, steady state response, and flow velocity for improved performance. An understanding of these developed technologies and methods will facilitate the development of lab-on-a-chip systems for point-of-care analysis.

  4. Does a higher 'quality points' score mean better care in stroke? An audit of general practice medical records.

    PubMed

    Williams, Peter Huw; de Lusignan, Simon

    2006-01-01

    The Royal College of Physicians (RCP) have produced guidelines for stroke management in primary care; this guidance is taken to be the gold standard for the care of people with stroke. UK general practitioners now have a quality-based contract which includes a Quality and Outcomes Framework (QOF). This consists of financially remunerated 'quality points' for specific disease areas, including stroke. Achievement of these quality points is measured by extracting a limited list of computer codes from practice computer systems. To investigate whether a high stroke quality score is associated with adherence to RCP guidelines. Examination of computer and written medical records of all patients with a diagnosis of stroke. Two general practices, one in southwest London, one in Surrey, with a combined practice population of over 20 000. Both practices had a similar age-sex profile and prevalence of stroke. One practice scored 93.5% (29/31) of the available stroke quality points. The other practice achieved 73.4% (22.75/31), and only did better in one stroke quality target. However, the practice scoring fewer quality points had much better adherence to RCP guidance: 96% of patients were assessed in secondary care compared with 79% (P=0.001); 64% of stroke patients were seen the same day, compared with 44%; 56% received rehabilitation compared with 37%. Higher quality points did not reflect better adherence to RCP guidance. This audit highlights a gap between relatively simplistic measures of quality in the QOF, dependent on the recording of a narrow range of computer codes, and the actual standard of care being delivered. Research is needed to see whether this finding is generalisable and how the Quality and Outcomes Framework might be better aligned with delivering best practice.

  5. Novel pH sensing semiconductor for point-of-care detection of HIV-1 viremia

    PubMed Central

    Gurrala, R.; Lang, Z.; Shepherd, L.; Davidson, D.; Harrison, E.; McClure, M.; Kaye, S.; Toumazou, C.; Cooke, G. S.

    2016-01-01

    The timely detection of viremia in HIV-infected patients receiving antiviral treatment is key to ensuring effective therapy and preventing the emergence of drug resistance. In high HIV burden settings, the cost and complexity of diagnostics limit their availability. We have developed a novel complementary metal-oxide semiconductor (CMOS) chip based, pH-mediated, point-of-care HIV-1 viral load monitoring assay that simultaneously amplifies and detects HIV-1 RNA. A novel low-buffer HIV-1 pH-LAMP (loop-mediated isothermal amplification) assay was optimised and incorporated into a pH sensitive CMOS chip. Screening of 991 clinical samples (164 on the chip) yielded a sensitivity of 95% (in vitro) and 88.8% (on-chip) at >1000 RNA copies/reaction across a broad spectrum of HIV-1 viral clades. Median time to detection was 20.8 minutes in samples with >1000 copies RNA. The sensitivity, specificity and reproducibility are close to that required to produce a point-of-care device which would be of benefit in resource poor regions, and could be performed on an USB stick or similar low power device. PMID:27829667

  6. Proactive therapeutic drug monitoring of infliximab: a comparative study of a new point-of-care quantitative test with two established ELISA assays.

    PubMed

    Afonso, J; Lopes, S; Gonçalves, R; Caldeira, P; Lago, P; Tavares de Sousa, H; Ramos, J; Gonçalves, A R; Ministro, P; Rosa, I; Vieira, A I; Dias, C C; Magro, F

    2016-10-01

    Therapeutic drug monitoring is a powerful strategy known to improve the clinical outcomes and to optimise the healthcare resources in the treatment of autoimmune diseases. Currently, most of the methods commercially available for the quantification of infliximab (IFX) are ELISA-based, with a turnaround time of approximately 8 h, and delaying the target dosage adjustment to the following infusion. To validate the first point-of-care IFX quantification device available in the market - the Quantum Blue Infliximab assay (Buhlmann, Schonenbuch, Switzerland) - by comparing it with two well-established methods. The three methods were used to assay the IFX concentration of spiked samples and of the serum of 299 inflammatory bowel diseases (IBD) patients undergoing IFX therapy. The point-of-care assay had an average IFX recovery of 92%, being the most precise among the tested methods. The Intraclass Correlation Coefficients of the point-of-care IFX assay vs. the two ELISA-based established methods were 0.889 and 0.939. Moreover, the accuracy of the point-of-care IFX compared with each of the two reference methods was 77% and 83%, and the kappa statistics revealed a substantial agreement (0.648 and 0.738). The Quantum Blue IFX assay can successfully replace the commonly used ELISA-based IFX quantification kits. This point-of-care IFX assay is able to deliver the results within 15 min makes it ideal for an immediate target concentration adjusted dosing. Moreover, it is a user-friendly desktop device that does not require specific laboratory facilities or highly specialised personnel. © 2016 John Wiley & Sons Ltd.

  7. Point-of-Care Testing for Anemia, Diabetes, and Hypertension: A Pharmacy-Based Model in Lima, Peru.

    PubMed

    Saldarriaga, Enrique M; Vodicka, Elisabeth; La Rosa, Sayda; Valderrama, Maria; Garcia, Patricia J

    Prevention and control of chronic diseases is a high priority for many low- and middle-income countries. This study evaluated the feasibility and acceptability of training pharmacy workers to provide point-of-care testing for 3 chronic diseases-hypertension, diabetes, and anemia-to improve disease detection and awareness through private pharmacies. We developed a multiphase training curriculum for pharmacists and pharmacy technicians to build capacity for identification of risk factors, patient education, point-of-care testing, and referral for abnormal results. We conducted a pre-post evaluation with participants and evaluated results using Student t test for proportions. We conducted point-of-care testing with pharmacy clients and evaluated acceptability by patient characteristics (age, gender, and type of patient) using multiple logistic regression. In total, 72 pharmacy workers (66%) completed the full training curriculum. Pretest scores indicated that pharmacists had more knowledge and skills in chronic disease risk factors, patient education, and testing than pharmacy technicians. All participants improved their knowledge and skills after the training, and post-test scores indicated that pharmacy technicians achieved the same level of competency as pharmacists (P < .01). Additionally, 698 clients received at least 1 test during the study; 53% completed the acceptability survey. Nearly 100% thought the pharmacy could provide faster results, faster and better attention, and better access to basic screening for hypertension, diabetes, and anemia than a traditional health center. Fast service was very important: 41% ranked faster results and 30% ranked faster attention as the most important factor for receiving diagnostic testing in the pharmacy. We found that it is both feasible for pharmacies and acceptable to clients to train pharmacy workers to provide point-of-care testing for anemia, diabetes, and hypertension. This innovative approach holds potential to

  8. Direct writing electrodes using a ball pen for paper-based point-of-care testing.

    PubMed

    Li, Zedong; Li, Fei; Hu, Jie; Wee, Wei Hong; Han, Yu Long; Pingguan-Murphy, Belinda; Lu, Tian Jian; Xu, Feng

    2015-08-21

    The integration of paper with an electrochemical device has attracted growing attention for point-of-care testing, where it is of great importance to fabricate electrodes on paper in a low-cost, easy and versatile way. In this work, we report a simple strategy for directly writing electrodes on paper using a pressure-assisted ball pen to form a paper-based electrochemical device (PED). This method is demonstrated to be capable of fabricating electrodes on paper with good electrical conductivity and electrochemical performance, holding great potential to be employed in point-of-care applications, such as in human health diagnostics and food safety detection. As examples, the PEDs fabricated using the developed method are applied for detection of glucose in artificial urine and melamine in sample solutions. Furthermore, our developed strategy is also extended to fabricate PEDs with multi-electrode arrays and write electrodes on non-planar surfaces (e.g., paper cup, human skin), indicating the potential application of our method in other fields, such as fabricating biosensors, paper electronics etc.

  9. Multi-center evaluation of the cobas® Liat® Influenza A/B & RSV assay for rapid point of care diagnosis.

    PubMed

    Gibson, Jane; Schechter-Perkins, Elissa M; Mitchell, Patricia; Mace, Sharon; Tian, Yu; Williams, Kemi; Luo, Robert; Yen-Lieberman, Belinda

    2017-10-01

    Point of Care Testing (POCT) provides the capability for rapid laboratory test results in patient care environments where a traditional clinical laboratory is not available. POCTs have shorter turn-around times (TATs), they may be performed by non-laboratory personnel, and the need for transport time is eliminated. The Food and Drug Administration (FDA) recently granted Clinical Laboratory Improvements Amendment (CLIA) waiver status to the cobas ® Influenza A/B & RSV assay, a rapid, accurate point-of-care test for Influenza and respiratory syncytial virus (RSV) performed on the Liat ® System. The performance characteristics of this test were determined though a multi-site study consisting of different point of care testing environments. Prospectively collected Nasopharyngeal (NP) swabs from 1361 patients seen at 8 primary care clinics and 4 emergency departments (EDs) and 295 retrospectively identified specimens were tested for Influenza A/B and RSV on the cobas ® Liat ® platform. Performance characteristics were determined through comparison to ProFlu+, a laboratory-based PCR test for Influenza A/B and RSV (reference test). Discordant specimens were adjudicated following bi-directional sequencing. The cobas ® Influenza A/B and RSV assay showed sensitivities of 99.6%, 99.3%, and 96.8% for Influenza A, Influenza B, and RSV, respectively as determined from percent positive agreement (PPA) following comparison to the reference test. Sequencing confirmed cobas ® Influenza A/B and RSV results in 49.2% of reference test discordant specimens, while crossing threshold data suggest increased sensitivity compared to the reference test. The cobas ® Influenza A/B and RSV assay was found to be a rapid, sensitive POCT for the detection of these viruses, and provides laboratory-quality PCR-based diagnostic results in point of care settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. The Role of Affordable, Point-of-Care Technologies for Cancer Care in Low- and Middle-Income Countries: A Review and Commentary

    PubMed Central

    Tandon, Pushpa; Divi, Rao; Ossandon, Miguel R.; Baker, Houston; Pearlman, Paul C.

    2017-01-01

    As the burden of non-communicable diseases such as cancer continues to rise in low- and middle-income countries (LMICs), it is essential to identify and invest in promising solutions for cancer control and treatment. Point-of-care technologies (POCTs) have played critical roles in curbing infectious disease epidemics in both high- and low-income settings, and their successes can serve as a model for transforming cancer care in LMICs, where access to traditional clinical resources is often limited. The versatility, cost-effectiveness, and simplicity of POCTs warrant attention for their potential to revolutionize cancer detection, diagnosis, and treatment. This paper reviews the landscape of affordable POCTs for cancer care in LMICs with a focus on imaging tools, in vitro diagnostics, and treatment technologies and aspires to encourage innovation and further investment in this space. PMID:29204328

  11. Through the eye of the suprasternal notch: point-of-care sonography for tuberculous mediastinal lymphadenopathy in children.

    PubMed

    Moseme, Tsepo; Andronikou, Savvas

    2014-06-01

    Diagnosis of pulmonary tuberculosis (TB) remains a challenge in the pediatric population because of the lack of sputum production for laboratory analysis. Chest radiography is used in the diagnosis of pulmonary TB and the hallmark of diagnosis is the demonstration of hilar or mediastinal lymphadenopathy. Point-of-care sonography of the mediastinum is an alternative to chest radiography in detection of tuberculous lymph nodes. In the rural district health care setting US is often the most commonly available imaging modality and its mobility makes it possible to examine patients at the point of care, reducing the need for patients to travel to a regional hospital to acquire a chest radiograph. We developed and used a simplified technique for performing mediastinal sonography in a pilot study of 30 children (age 0 to 13 years) with proven or suspected TB. We can report that the procedure was successful in demonstrating the anterior mediastinal anatomy and predefined zones in all 30 children. We also recorded lymphadenopathy in 12 children. This report describes our procedural methods and initial results.

  12. “I Do Feel Like a Scientist at Times”: A Qualitative Study of the Acceptability of Molecular Point-Of-Care Testing for Chlamydia and Gonorrhoea to Primary Care Professionals in a Remote High STI Burden Setting

    PubMed Central

    Natoli, Lisa; Guy, Rebecca J.; Shephard, Mark; Causer, Louise; Badman, Steven G.; Hengel, Belinda; Tangey, Annie; Ward, James; Coburn, Tony; Anderson, David; Kaldor, John; Maher, Lisa

    2015-01-01

    Background Point-of-care tests for chlamydia (CT) and gonorrhoea (NG) could increase the uptake and timeliness of testing and treatment, contribute to improved disease control and reduce reproductive morbidity. The GeneXpert (Xpert CT/NG assay), suited to use at the point-of-care, is being used in the TTANGO randomised controlled trial (RCT) in 12 remote Australian health services with a high burden of sexually transmissible infections (STIs). This represents the first ever routine use of a molecular point-of-care diagnostic for STIs in primary care. The purpose of this study was to explore the acceptability of the GeneXpert to primary care staff in remote Australia. Methods In-depth qualitative interviews were conducted with 16 staff (registered or enrolled nurses and Aboriginal Health Workers/Practitioners) trained and experienced with GeneXpert testing. Interviews were digitally-recorded and transcribed verbatim prior to content analysis. Results Most participants displayed positive attitudes, indicating the test was both easy to use and useful in their clinical context. Participants indicated that point-of-care testing had improved management of STIs, resulting in more timely and targeted treatment, earlier commencement of partner notification, and reduced follow up efforts associated with client recall. Staff expressed confidence in point-of-care test results and treating patients on this basis, and reported greater job satisfaction. While point-of-care testing did not negatively impact on client flow, several found the manual documentation processes time consuming, suggesting that improved electronic connectivity and test result transfer between the GeneXpert and patient management systems could overcome this. Managing positive test results in a shorter time frame was challenging for some but most found it satisfying to complete episodes of care more quickly. Conclusions In the context of a RCT, health professionals working in remote primary care in Australia

  13. Neurosensory Deficits Vary as a Function of Point of Care in Pediatric Mild Traumatic Brain Injury.

    PubMed

    Mayer, Andrew R; Wertz, Christopher; Ryman, Sephira G; Storey, Eileen P; Park, Grace; Phillips, John; Dodd, Andrew B; Oglesbee, Scott; Campbell, Richard; Yeo, Ronald A; Wasserott, Benjamin; Shaff, Nicholas A; Leddy, John J; Mannix, Rebekah; Arbogast, Kristy B; Meier, Timothy B; Grady, Matthew F; Master, Christina L

    2018-05-15

    Neurosensory abnormalities are frequently observed following pediatric mild traumatic brain injury (pmTBI) and may underlie the expression of several common concussion symptoms and delay recovery. Importantly, active evaluation of neurosensory functioning more closely approximates real-world (e.g., physical and academic) environments that provoke symptom worsening. The current study determined whether symptom provocation (i.e., during neurosensory examination) improved classification accuracy relative to pre-examination symptom levels and whether symptoms varied as a function of point of care. Eighty-one pmTBI were recruited from the pediatric emergency department (PED; n = 40) or outpatient concussion clinic (n = 41), along with matched (age, sex, and education) healthy controls (HC; n = 40). All participants completed a brief (∼ 12 min) standardized neurosensory examination and clinical questionnaires. The magnitude of symptom provocation upon neurosensory examination was significantly higher for concussion clinic than for PED patients. Symptom provocation significantly improved diagnostic classification accuracy relative to pre-examination symptom levels, although the magnitude of improvement was modest, and was greater in the concussion clinic. In contrast, PED patients exhibited worse performance on measures of balance, vision, and oculomotor functioning than the concussion clinic patients, with no differences observed between both samples and HC. Despite modest sample sizes, current findings suggest that point of care represents a critical but highly under-studied variable that may influence outcomes following pmTBI. Studies that rely on recruitment from a single point of care may not generalize to the entire pmTBI population in terms of how neurosensory deficits affect recovery.

  14. National Institute of Biomedical Imaging and Bioengineering Point-of-Care Technology Research Network: Advancing Precision Medicine

    PubMed Central

    Ford Carleton, Penny; Parrish, John A.; Collins, John M.; Crocker, J. Benjamin; Dixon, Ronald F.; Edgman-Levitan, Susan; Lewandrowski, Kent B.; Stahl, James E.; Klapperich, Catherine; Cabodi, Mario; Gaydos, Charlotte A.; Rompalo, Anne M.; Manabe, Yukari; Wang, Tza-Huei; Rothman, Richard; Geddes, Chris D.; Widdice, Lea; Jackman, Joany; Mathura, Rishi A.; Lash, Tiffani Bailey

    2016-01-01

    To advance the development of point-of-care technology (POCT), the National Institute of Biomedical Imaging and Bioengineering established the POCT Research Network (POCTRN), comprised of Centers that emphasize multidisciplinary partnerships and close facilitation to move technologies from an early stage of development into clinical testing and patient use. This paper describes the POCTRN and the three currently funded Centers as examples of academic-based organizations that support collaborations across disciplines, institutions, and geographic regions to successfully drive innovative solutions from concept to patient care. PMID:27730014

  15. Teaching Evidence-Based Medicine in the Era of Point-of-Care Databases: The Case of the Giant Bladder Stone.

    PubMed

    Kash, Melissa J

    2016-01-01

    In an era where physicians rely on point-of-care databases that provide filtered, pre-appraised, and quickly accessible clinical information by smartphone applications, it is difficult to teach medical students the importance of knowing not only when it is appropriate to search the primary medical literature but also how to do it. This column will describe how librarians at an academic health sciences library use an unusual clinical case to make demonstrations of searching primary medical literature real and meaningful to medical students, and to illustrate vividly the importance of knowing what to do when the answer to a clinical question cannot be found in a point-of-care database.

  16. Evaluation of the performance of a point-of-care method for total and differential white blood cell count in clozapine users.

    PubMed

    Bui, H N; Bogers, J P A M; Cohen, D; Njo, T; Herruer, M H

    2016-12-01

    We evaluated the performance of the HemoCue WBC DIFF, a point-of-care device for total and differential white cell count, primarily to test its suitability for the mandatory white blood cell monitoring in clozapine use. Leukocyte count and 5-part differentiation was performed by the point-of-care device and by routine laboratory method in venous EDTA-blood samples from 20 clozapine users, 20 neutropenic patients, and 20 healthy volunteers. From the volunteers, also a capillary sample was drawn. Intra-assay reproducibility and drop-to-drop variation were tested. The correlation between both methods in venous samples was r > 0.95 for leukocyte, neutrophil, and lymphocyte counts. The correlation between point-of-care (capillary sample) and routine (venous sample) methods for these cells was 0.772; 0.817 and 0.798, respectively. Only for leukocyte and neutrophil counts, the intra-assay reproducibility was sufficient. The point-of-care device can be used to screen for leukocyte and neutrophil counts. Because of the relatively high measurement uncertainty and poor correlation with venous samples, we recommend to repeat the measurement with a venous sample if cell counts are in the lower reference range. In case of clozapine therapy, neutropenia can probably be excluded if high neutrophil counts are found and patients can continue their therapy. © 2016 John Wiley & Sons Ltd.

  17. The universe of ANA testing: a case for point-of-care ANA testing.

    PubMed

    Konstantinov, Konstantin N; Rubin, Robert L

    2017-12-01

    Testing for total antinuclear antibodies (ANA) is a critical tool for diagnosis and management of autoimmune diseases at both the primary care and subspecialty settings. Repurposing of ANA from a test for lupus to a test for any autoimmune condition has driven the increase in ANA requests. Changes in ANA referral patterns include early or subclinical autoimmune disease detection in patients with low pre-test probability and use of negative ANA results to rule out underlying autoimmune disease. A positive result can lead to further diagnostic considerations. Currently, ANA tests are performed in centralized laboratories; an alternative would be ANA testing at the clinical point-of-care (POC). By virtue of its near real-time data collection capability, low cost, and ease of use, we believe the POC ANA has the potential to enable a new paradigm shift in autoimmune serology testing.

  18. Point of Care Ultrasound Diagnosis of Empyema.

    PubMed

    Nelson, Mathew; Stankard, Brendon; Greco, Jeffrey; Okumura, Yoshito

    2016-08-01

    Emergency ultrasonography is an efficient and cost effective tool for patients who are in respiratory distress. Chest radiographs can yield limited information for these patients. Computed tomography scans have long been the criterion standard for advanced imaging in patients with respiratory complaints, but point of care ultrasound (POCUS) can be performed at bedside, does not expose the patient to radiation, and at times may provide more information than a computed tomography scan. A 60-year-old man with a medical history of hypertension presented to the emergency department complaining of a productive cough associated with fever, weakness, and progressively worsening dyspnea on exertion over the previous 1 to 2 weeks. The physical examination was remarkable for rhonchi in the right upper lobe and diminished breath sounds throughout the right lung. POCUS was performed, and the results revealed severe atelectasis and hepatization of the right lung parenchyma with visualized air bronchograms. Complex hypoechoic material with a posterior spine sign was noted, which increased concern for complex consolidation and effusion. The diagnosis of pneumonia with empyema was made. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: POCUS has become a much more commonly used imaging modality within many emergency departments. Ultrasound is more sensitive than chest radiographs for identifying pathologies such as pneumothorax and simple effusions. This case shows how well POCUS can diagnose empyema even in the setting of diagnostic uncertainty of computed tomographic imaging. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Evaluation of a handheld point-of-care analyser for measurement of creatinine in cats.

    PubMed

    Reeve, Jenny; Warman, Sheena; Lewis, Daniel; Watson, Natalie; Papasouliotis, Kostas

    2017-02-01

    Objectives The aim of the study was to evaluate whether a handheld creatinine analyser (StatSensor Xpress; SSXp), available for human patients, can be used to measure creatinine reliably in cats. Methods Analytical performance was evaluated by determining within- and between-run coefficient of variation (CV, %), total error observed (TE obs , %) and sigma metrics. Fifty client-owned cats presenting for investigation of clinical disease had creatinine measured simultaneously, using SSXp (whole blood and plasma) and a reference instrument (Konelab, serum); 48 paired samples were included in the study. Creatinine correlation between methodologies (SSXp vs Konelab) and sample types (SSXp whole blood vs SSXp plasma ) was assessed by Spearman's correlation coefficient and agreement was determined using Bland-Altman difference plots. Each creatinine value was assigned an IRIS stage (1-4); correlation and agreement between Konelab and SSXp IRIS stages were evaluated. Results Within-run CV (4.23-8.85%), between-run CV (8.95-11.72%), TE obs (22.15-34.92%) and sigma metrics (⩽3) did not meet desired analytical requirements. Correlation between sample types was high (SSXp whole blood vs SSXp plasma ; r = 0.89), and between instruments was high (SSXp whole blood vs Konelab serum ; r = 0.85) to very high (SSXp plasma vs Konelab serum ; r = 0.91). Konelab and SSXp whole blood IRIS scores exhibited high correlation ( r = 0.76). Packed cell volume did not significantly affect SSXp determination of creatinine. Bland-Altman difference plots identified a positive bias for the SSXp (7.13 μmol/l SSXp whole blood ; 20.23 μmol/l SSXp plasma ) compared with the Konelab. Outliers (1/48 whole blood; 2/48 plasma) occurred exclusively at very high creatinine concentrations. The SSXp failed to identify 2/21 azotaemic cats. Conclusions and relevance Analytical performance of the SSXp in feline patients is not considered acceptable. The SSXp exhibited a high to very high correlation compared

  20. 3D printed microfluidic mixer for point-of-care diagnosis of anemia.

    PubMed

    Plevniak, Kimberly; Campbell, Matthew; Mei He

    2016-08-01

    3D printing has been an emerging fabrication tool in prototyping and manufacturing. We demonstrated a 3D microfluidic simulation guided computer design and 3D printer prototyping for quick turnaround development of microfluidic 3D mixers, which allows fast self-mixing of reagents with blood through capillary force. Combined with smartphone, the point-of-care diagnosis of anemia from finger-prick blood has been successfully implemented and showed consistent results with clinical measurements. Capable of 3D fabrication flexibility and smartphone compatibility, this work presents a novel diagnostic strategy for advancing personalized medicine and mobile healthcare.

  1. Identification of design features to enhance utilization and acceptance of systems for Internet-based decision support at the point of care.

    PubMed Central

    Gadd, C. S.; Baskaran, P.; Lobach, D. F.

    1998-01-01

    Extensive utilization of point-of-care decision support systems will be largely dependent on the development of user interaction capabilities that make them effective clinical tools in patient care settings. This research identified critical design features of point-of-care decision support systems that are preferred by physicians, through a multi-method formative evaluation of an evolving prototype of an Internet-based clinical decision support system. Clinicians used four versions of the system--each highlighting a different functionality. Surveys and qualitative evaluation methodologies assessed clinicians' perceptions regarding system usability and usefulness. Our analyses identified features that improve perceived usability, such as telegraphic representations of guideline-related information, facile navigation, and a forgiving, flexible interface. Users also preferred features that enhance usefulness and motivate use, such as an encounter documentation tool and the availability of physician instruction and patient education materials. In addition to identifying design features that are relevant to efforts to develop clinical systems for point-of-care decision support, this study demonstrates the value of combining quantitative and qualitative methods of formative evaluation with an iterative system development strategy to implement new information technology in complex clinical settings. Images Figure 1 PMID:9929188

  2. Identification of design features to enhance utilization and acceptance of systems for Internet-based decision support at the point of care.

    PubMed

    Gadd, C S; Baskaran, P; Lobach, D F

    1998-01-01

    Extensive utilization of point-of-care decision support systems will be largely dependent on the development of user interaction capabilities that make them effective clinical tools in patient care settings. This research identified critical design features of point-of-care decision support systems that are preferred by physicians, through a multi-method formative evaluation of an evolving prototype of an Internet-based clinical decision support system. Clinicians used four versions of the system--each highlighting a different functionality. Surveys and qualitative evaluation methodologies assessed clinicians' perceptions regarding system usability and usefulness. Our analyses identified features that improve perceived usability, such as telegraphic representations of guideline-related information, facile navigation, and a forgiving, flexible interface. Users also preferred features that enhance usefulness and motivate use, such as an encounter documentation tool and the availability of physician instruction and patient education materials. In addition to identifying design features that are relevant to efforts to develop clinical systems for point-of-care decision support, this study demonstrates the value of combining quantitative and qualitative methods of formative evaluation with an iterative system development strategy to implement new information technology in complex clinical settings.

  3. Augmentation of point of injury care: Reducing battlefield mortality-The IDF experience.

    PubMed

    Benov Avi; Elon, Glassberg; Baruch, Erez Nissim; Avi, Shina; Gilad, Twig; Moran, Levi; Itay, Zoarets; Ram, Sagi; Tarif, Bader; David, Dagan; Avraham, Yitzhak; Yitshak, Kreiss

    2016-05-01

    In 2012, the Israel Defense Forces Medical Corps (IDF-MC) set a goal of reducing mortality and eliminating preventable death on the battlefield. A force buildup plan entitled "My Brother's Keeper" was launched addressing: trauma medicine, training, change of Clinical Practice Guidelines (CPGs), injury prevention, data collection, global collaboration and more. The aim of this article is to examine how military medical care has evolved due "My Brother's Keeper" between Second Lebanon War (SLW, 2006) to Operation Protective Edge (OPE, 2014). Records of all casualties during OPE and SLW were extracted and analyzed from the I.D.F Trauma Registry. Noncombat injuries and civilian injuries from missile attacks were excluded from this analysis. The plans main impacts were; incorporation of a physician or paramedic as an integral part of each fighting company, implementation of new CPGs, introduction of new approaches for extremity haemorrhage control and Remote Damage Control Resuscitation at point of injury (POI) using single donor reconstituted freeze dried plasma (25 casualties) and transexamic acid (98 casualties). During OPE, 704 soldiers sustained injuries compared with 833 casualties during SLW. Fatalities were 65 and 119, respectively, cumulating to Case Fatality Rate of 9.2% and 14.3%, respectively. Significant changes in the way the IDF-MC provides combat casualty care have been made in recent years. It is the transformation from concept to doctrine and integration into a structured and Goal-Oriented Casualty Care System, especially POI care that led to the unprecedented survival rates in IDF as shown in this conflict. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. A paper based graphene-nanocauliflower hybrid composite for point of care biosensing.

    PubMed

    Burrs, S L; Bhargava, M; Sidhu, R; Kiernan-Lewis, J; Gomes, C; Claussen, J C; McLamore, E S

    2016-11-15

    We demonstrate the first report of graphene paper functionalized with fractal platinum nanocauliflower for use in electrochemical biosensing of small molecules (glucose) or detection of pathogenic bacteria (Escherichia coli O157:H7). Raman spectroscopy, scanning electron microscopy and energy dispersive spectroscopy show that graphene oxide-coated nanocellulose was partially reduced by both thermal treatment, and further reduced by chemical treatment (ascorbic acid). Fractal nanoplatinum with cauliflower-like morphology was formed on the reduced graphene oxide paper using pulsed sonoelectrodeposition, producing a conductive paper with an extremely high electroactive surface area (0.29±0.13cm(2)), confirmed by cyclic voltammetry and electrochemical impedance spectroscopy. The platinum surface was functionalized with either glucose oxidase (via chitosan encapsulation) or a RNA aptamer (via covalent linking) for demonstration as a point of care biosensor. The detection limit for both glucose (0.08±0.02μM) and E. coli O157:H7 (≈4 CFUmL(-1)) were competitive with, or superior to, previously reported devices in the biosensing literature. The response time (6s for glucose and 12min for E. coli) were also similar to silicon biochip and commercial electrode sensors. The results demonstrate that the nanocellulose-graphene-nanoplatinum material is an excellent paper-based platform for development of electrochemical biosensors targeting small molecules or whole cells for use in point of care biosensing. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Depression treatment for impoverished mothers by point-of-care providers: A randomized controlled trial.

    PubMed

    Segre, Lisa S; Brock, Rebecca L; O'Hara, Michael W

    2015-04-01

    Depression in low-income, ethnic-minority women of childbearing age is prevalent and compromises infant and child development. Yet numerous barriers prevent treatment delivery. Listening Visits (LV), an empirically supported intervention developed for delivery by British home-visiting nurses, could address this unmet mental health need. This randomized controlled trial (RCT) evaluated the effectiveness of LV delivered at a woman's usual point-of-care, including home visits or an ob-gyn office. Listening Visits were delivered to depressed pregnant women or mothers of young children by their point-of-care provider (e.g., home visitor or physician's assistant), all of whom had low levels of prior counseling experience. Three quarters of the study's participants were low-income. Of those who reported ethnicity, all identified themselves as minorities. Participants from 4 study sites (N = 66) were randomized in a 2:1 ratio, to LV or a wait-list control group (WLC). Assessments, conducted at baseline and 8 weeks, evaluated depression, quality of life, and treatment satisfaction. Depressive severity, depressive symptoms, and quality of life significantly improved among LV recipients as compared with women receiving standard social/health services. Women valued LV as evidenced by their high attendance rates and treatment satisfaction ratings. In a stepped model of depression care, LV can provide an accessible, acceptable, and effective first-line treatment option for at-risk women who otherwise are unlikely to receive treatment. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  6. Twelve-Month Prospective Randomized Study of Pharmacists Utilizing Point-Of-Care Testing for Metabolic Syndrome and Related Conditions in Subjects Prescribed Antipsychotics

    PubMed Central

    Shuster, Sara M.; Davey, Cynthia S.

    2014-01-01

    Objective: Determine the percentage of subjects taking antipsychotics who meet criteria for metabolic syndrome based on point-of-care testing analyses. Evaluate pharmacist comprehensive medication management services using point-of-care tests to reduce the mean difference in number of metabolic syndrome risk parameters at 6 and 12 months. Method: This 12-month, prospective, multisite, randomized, controlled study included 120 subjects taking antipsychotics (mean [SD] age of 42.9 [11.3] years) recruited from 3 community mental health clinics in Minnesota. Subjects consented to receive either pharmacist (PCS; n = 60) or no pharmacist (NCS; n = 60) comprehensive medication management services. Data were collected from February 2010 to January 2012. Results: No statistical differences in metabolic syndrome based on point-of-care tests were observed between the 2 groups at baseline (PCS: 85.2%, n = 46 versus NCS: 71.2%, n = 42, P = .073) or at 12 months (PCS: 84.4%, n = 38 versus NCS: 70.2%, n = 33, P = .104). Subjects, overall, screened positive at baseline for dyslipidemia (85.8%, n = 106), hypertension (52.5%, n = 63), and diabetes (22.5%, n = 27) based on point-of-care testing for metabolic risk criteria. After 12 months, a nonsignificant (P = .099) higher adjusted mean number of metabolic syndrome parameters in PCS subjects compared to NCS subjects (mean difference [95% CI] = 0.41 [−0.08 to 0.90]) were found. Conclusions: A relatively high proportion of subjects met criteria for metabolic syndrome, although no significant improvement was observed between the groups after 12 months. Point-of-care test analyses identified a high proportion of subjects meeting criteria for dyslipidemia, hypertension, and diabetes. Utilizing point-of-care tests in mental health settings and fostering interprofessional partnerships with comprehensive medication management pharmacists may improve identification and long-term management of metabolic risks among patients prescribed

  7. Point-of-care Helicobacter pylori urine antibody detection in a multi-ethnic adult population in the United States.

    PubMed

    Opekun, Antone R; Luu, Phong; Gotschall, Ann B; Abdalla, Nageeb; Torres, Elizabeth; Rudd, Summer B; Graham, David Y; Nurgalieva, Zhannat Z; Tsuchiya, Kyoko

    2006-07-01

    A need exists for accurate point-of-care tests for diagnosis of Helicobacter pylori (H. pylori) infection to evaluate a rapid urine-H. pylori antibody test device for detection of H. pylori infection in a point-of-care setting in the United States. A multi-center study in a multi-ethnic population compared the RAPIRUN urine antibody test with the (13)C-urea breath test (C-UBT) and a traditional serologic test, the high-molecular-weight cell-associated protein enzyme immunoassay (HM-CAP EIA). The primary comparator was with "definite positive" and "definite negative" patients defined as a concordance of combined results of the UBT and the HM-CAP IgG EIA. Overall, 188 eligible patients were enrolled (61 men, age range: 18-73 years, including 84 Hispanics, 73 Asian-Pacific Americans, 22 Black African-Americans, 6 non-Hispanic Caucasians, and 3 of "other" ethnicity). Compared with "definite positive" and "definite negative" results, the sensitivity and specificity of the urine antibody test were 0.9 and 1.0, respectively. The urine antibody test proved suitable for point-of-care rapid diagnosis of anti-H. pylori antibodies indicative of active or past H. pylori infection.

  8. The Matrix Metalloproteinase 9 Point-of-Care Test in Dry Eye.

    PubMed

    Lanza, Nicole L; Valenzuela, Felipe; Perez, Victor L; Galor, Anat

    2016-04-01

    Dry eye is a common, multifactorial disease currently diagnosed by a combination of symptoms and signs. However, the subjective symptoms of dry eye poorly correlate to the current gold standard for diagnostic tests, reflecting the need to develop better objective tests for the diagnosis of dry eye. This review considers the role of ocular surface matrix metalloproteinase 9 (MMP-9) in dry eye and the implications of a novel point-of-care test that measures MMP-9 levels, InflammaDry (RPS, Sarasota, FL) on choosing appropriate therapeutic treatments. Published by Elsevier Inc.

  9. Advances in point-of-care technologies for molecular diagnostics.

    PubMed

    Zarei, Mohammad

    2017-12-15

    Advances in miniaturization, nanotechnology, and microfluidics, along with developments in cloud-connected point-of-care (POC) diagnostics technologies are pushing the frontiers of POC devices toward low-cost, user-friendly, and enhanced sensitivity molecular-level diagnostics. The combination of various bio-sensing platforms within smartphone-integrated electronic readers provides accurate on-site and on-time diagnostics based on various types of chemical and biological targets. Further, 3D printing technology shows a huge potential toward fabrication and improving the performance of POC devices. Integration of skin-like flexible sensors with wireless communication technology creates a unique opportunity for continuous, real-time monitoring of patients for both preventative healthcare and during disease outbreaks. Here, we review recent developments and advances in POC technologies and describe how these advances enhance the performance of POC platforms. Also, this review describes challenges, directions, and future trends on application of emerging technologies in POC diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Principles of Point of Care Culture, the Spatial Care Path™, and Enabling Community and Global Resilience: Enabling Community and Global Resilience.

    PubMed

    Gerald, J Kost; William, J Ferguson; Laurie, E Kost

    2014-09-01

    This article a) defines point of care (POC) culture; b) presents seven underlying fundamental principles; c) describes the importance of needs assessment; d) introduces a new innovation, the spatial care path™; and e) illustrates how POC testing that properly fulfills needs and spatial care paths™ enable community and global resilience. Often, POC testing supplants the conventional clinical laboratory, which may be too distant, prohibitively expensive, or simply not available in limited-resource settings. New POC technologies "fit" future medical problem solving. Screening and testing directly in the home or primary care facilitate rapid diagnosis, monitoring, and treatment. In contrast to the past where attention has been placed on emergency departments, hospitals, and referral centers, the spatial care path™ starts with the patient and guides him or her through an efficient strategy of care in small-world networks (SWNs) defined by local geography and topology, long-standing customs, public health jurisdictions, and geographic information systems (GIS). POC testing needs in limited-resource settings are striking. Fulfillment is best guided by thorough understanding of POC culture. Quick feedback and fast decision-making by patients and physicians alike yield significant value that motivates changes in patient lifestyles and physician interactions. Culturally sensitive technology assimilation addresses leadership challenges in nations adapting to increasing populations of young and old, despite scarcity of resources. The spatial care path™ facilitates an essential balance of prevention and intervention in public health and shifts future focus to the patient, empowerment, and primary care within the context of POC culture.

  11. Phospholipase A2 as a point of care alternative to serum amylase and pancreatic lipase

    NASA Astrophysics Data System (ADS)

    Liu, Nathan J.; Chapman, Robert; Lin, Yiyang; Bentham, Andrew; Tyreman, Matthew; Philips, Natalie; Khan, Shahid A.; Stevens, Molly M.

    2016-06-01

    Acute pancreatitis is a relatively common and potentially fatal condition, but the presenting symptoms are non-specific and diagnosis relies largely on the measurement of amylase activity by the hospital clinical laboratory. In this work we develop a point of care test for pancreatitis measuring concentration of secretory phospholipase A2 group IB (sPLA2-IB). Novel antibodies for sPLA2-IB were raised and used to design an ELISA and a lateral flow device (LFD) for the point of care measurement of sPLA2-IB concentration, which was compared to pancreatic amylase activity, lipase activity, and sPLA2-IB activity in 153 serum samples. 98 of these samples were obtained from the pathology unit of a major hospital and classified retrospectively according to presence or absence of pancreatitis, and the remaining 55 were obtained from commercial sources to serve as high lipase (n = 20), CA19-9 positive (n = 15), and healthy (n = 20) controls. sPLA2-IB concentration correlated well with the serum activity of both amylase and lipase, and performed at least as well as either markers in the differentiation of pancreatitis from controls.Acute pancreatitis is a relatively common and potentially fatal condition, but the presenting symptoms are non-specific and diagnosis relies largely on the measurement of amylase activity by the hospital clinical laboratory. In this work we develop a point of care test for pancreatitis measuring concentration of secretory phospholipase A2 group IB (sPLA2-IB). Novel antibodies for sPLA2-IB were raised and used to design an ELISA and a lateral flow device (LFD) for the point of care measurement of sPLA2-IB concentration, which was compared to pancreatic amylase activity, lipase activity, and sPLA2-IB activity in 153 serum samples. 98 of these samples were obtained from the pathology unit of a major hospital and classified retrospectively according to presence or absence of pancreatitis, and the remaining 55 were obtained from commercial sources to

  12. Point-of-Care Hemoglobin/Hematocrit Testing: Comparison of Methodology and Technology.

    PubMed

    Maslow, Andrew; Bert, Arthur; Singh, Arun; Sweeney, Joseph

    2016-04-01

    Point-of-care (POC) testing allows rapid assessment of hemoglobin (Hgb) and hematocrit (Hct) values. This study compared 3 POC testing devices--the Radical-7 pulse oximeter (Radical-7, Neuchȃtel, Switzerland), the i-STAT (Abbott Point of Care, Princeton, NJ), and the GEM 4000 (Instrumentation Laboratory, Bedford, MA)--to the hospital reference device, the UniCel DxH 800 (Beckman Coulter, Brea, CA) in cardiac surgery patients. Prospective study. Tertiary care cardiovascular center. Twenty-four consecutive elective adult cardiac surgery patients. Hgb and Hct values were measured using 3 POC devices (the Radical-7, i-STAT, and GEM 4000) and a reference laboratory device (UniCel DxH 800). Data were collected simultaneously before surgery, after heparin administration, after heparin reversal with protamine, and after sternal closure. Data were analyzed using bias analyses. POC testing data were compared with that of the reference laboratory device. Hgb levels ranged from 6.8 to 15.1 g/dL, and Hct levels ranged from 20.1% to 43.8%. The overall mean bias was lowest with the i-STAT (Hct, 0.22%; Hgb 0.05 g/dL) compared with the GEM 4000 (Hct, 2.15%; Hgb, 0.63 g/dL) and the Radical-7 (Hgb 1.16 g/dL). The range of data for the i-STAT and Radical-7 was larger than that with the GEM 4000, and the pattern or slopes changed significantly with the i-STAT and Radical-7, whereas that of the GEM 4000 remained relatively stable. The GEM 4000 demonstrated a consistent overestimation of laboratory data, which tended to improve after bypass and at lower Hct/Hgb levels. The i-STAT bias changed from overestimation to underestimation, the latter in the post-cardiopulmonary bypass period and at lower Hct/Hgb levels. By contrast, the Radical-7 biases increased during the surgical procedure and in the lower ranges of Hgb. Important clinical differences and limitations were found among the 3 POC testing devices that should caution clinicians from relying on these data as sole determinants of

  13. Polychannel Systems for Mass Digital Communication

    DTIC Science & Technology

    1988-07-01

    years additional systems similar to ours have become operational, including X*Press, Main- stream Data, and Stargate . X*Press Information Services...cities in the United States, and Stargate uses the satellite TV station WTBS to transmit electronic bulletin boards to remote com- puter sites

  14. Point-of-care test for cervical cancer in LMICs.

    PubMed

    Mohammed, Sulma I; Ren, Wen; Flowers, Lisa; Rajwa, Bartek; Chibwesha, Carla J; Parham, Groesbeck P; Irudayaraj, Joseph M K

    2016-04-05

    Cervical cancer screening using Papanicolaou's smear test has been highly effective in reducing death from this disease. However, this test is unaffordable in low- and middle-income countries, and its complexity has limited wide-scale uptake. Alternative tests, such as visual inspection with acetic acid or Lugol's iodine and human papillomavirus DNA, are sub-optimal in terms of specificity and sensitivity, thus sensitive and affordable tests with high specificity for on-site reporting are needed. Using proteomics and bioinformatics, we have identified valosin-containing protein (VCP) as differentially expressed between normal specimens and those with cervical intra-epithelial neoplasia grade 2/3 (CIN2/CIN3+) or worse. VCP-specific immunohistochemical staining (validated by a point-of-care technology) provided sensitive (93%) and specific (88%) identification of CIN2/CIN3+ and may serve as a critical biomarker for cervical-cancer screening. Future efforts will focus on further refinements to enhance analytic sensitivity and specificity of our proposed test, as well as on prototype development.

  15. Integration of Stable Droplet Formation on a CD Microfluidic Device for Extreme Point of Care Applications

    NASA Astrophysics Data System (ADS)

    Ganesh, Shruthi Vatsyayani

    With the advent of microfluidic technologies for molecular diagnostics, a lot of emphasis has been placed on developing diagnostic tools for resource poor regions in the form of Extreme Point of Care devices. To ensure commercial viability of such a device there is a need to develop an accurate sample to answer system, which is robust, portable, isolated yet highly sensitive and cost effective. This need has been a driving force for research involving integration of different microsystems like droplet microfluidics, Compact-disc (CD)microfluidics along with sample preparation and detection modules on a single platform. This work attempts to develop a proof of concept prototype of one such device using existing CD microfluidics tools to generate stable droplets used in point of care diagnostics (POC diagnostics). Apart from using a fairly newer technique for droplet generation and stabilization, the work aims to develop this method focused towards diagnostics for rural healthcare. The motivation for this work is first described with an emphasis on the current need for diagnostic testing in rural health-care and the general guidelines prescribed by WHO for such a sample to answer system. Furthermore, a background on CD and droplet microfluidics is presented to understand the merits and de-merits of each system and the need for integrating the two. This phase of the thesis also includes different methods employed/demonstrated to generate droplets on a spinning platform. An overview on the detection platforms is also presented to understand the challenges involved in building an extreme point of care device. In the third phase of the thesis, general manufacturing techniques and materials used to accomplish this work is presented. Lastly, design trials for droplet generation is presented. The shortcomings of these trials are solved by investigating mechanisms pertaining to design modification and use of agarose based droplet generation to ensure a more robust sample

  16. Quantum Chemistry in Great Britain: Developing a Mathematical Framework for Quantum Chemistry

    NASA Astrophysics Data System (ADS)

    Simões, Ana; Gavroglu, Kostas

    By 1935 quantum chemistry was already delineated as a distinct sub-discipline due to the contributions of Fritz London, Walter Heitler, Friedrich Hund, Erich Hückel, Robert Mulliken, Linus Pauling, John van Vleck and John Slater. These people are credited with showing that the application of quantum mechanics to the solution of chemical problems was, indeed, possible, especially so after the introduction of a number of new concepts and the adoption of certain approximation methods. And though a number of chemists had started talking of the formation of theoretical or, even, mathematical chemistry, a fully developed mathematical framework of quantum chemistry was still wanting. The work of three persons in particular-of John E. Lennard-Jones, Douglas R. Hartree, and Charles Alfred Coulson-has been absolutely crucial in the development of such a framework. In this paper we shall discuss the work of these three researchers who started their careers in the Cambridge tradition of mathematical physics and who at some point of their careers all became professors of applied mathematics. We shall argue that their work consisted of decisive contributions to the development of such a mathematical framework for quantum chemistry.

  17. Chemistry teachers’ understanding of science process skills in relation of science process skills assessment in chemistry learning

    NASA Astrophysics Data System (ADS)

    Hikmah, N.; Yamtinah, S.; Ashadi; Indriyanti, N. Y.

    2018-05-01

    A Science process skill (SPS) is a fundamental scientific method to achieve good knowledge. SPS can be categorized into two levels: basic and integrated. Learning SPS helps children to grow as individuals who can access knowledge and know how to acquire it. The primary outcomes of the scientific process in learning are the application of scientific processes, scientific reasoning, accurate knowledge, problem-solving, and understanding of the relationship between science, technology, society, and everyday life’s events. Teachers’ understanding of SPS is central to the application of SPS in a learning process. Following this point, this study aims to investigate the high school chemistry teachers’ understanding of SPS pertains to their assessment of SPS in chemistry learning. The understanding of SPS is measured from the conceptual and operational aspects of SPS. This research uses qualitative analysis method, and the sample consists of eight chemistry teachers selected by random sampling. A semi-structured interview procedure is used to collect the data. The result of the analysis shows that teachers’ conceptual and operational understanding of SPS is weak. It affects the accuracy and appropriateness of the teacher’s selection of SPS assessment in chemistry learning.

  18. Point-of-care ultrasound performed by a medical student compared to physical examination by vascular surgeons in the detection of abdominal aortic aneurysms.

    PubMed

    Mai, Trinh; Woo, Michael Y; Boles, Kim; Jetty, Prasad

    2018-05-16

    To determine the test characteristics of point-of-care ultrasonography performed by a medical student versus physical examination by vascular surgeons compared to a gold standard reference scan for the detection of abdominal aortic aneurysms. We conducted a prospective, observer-blinded study recruiting patients from an outpatient vascular surgery clinic. Participants were screened for abdominal aortic aneurysms by standardized physical examination by a blinded vascular surgeon, followed by a point-of-care ultrasound examination by a blinded medical student. The student underwent prior training by a vascular sonographer and emergency physician on 60 patients (16 were supervised). Ultrasonography was used to visualize and measure the proximal, mid, and distal aortic diameters. The maximal aortic diameter was noted and compared to measurements obtained by the reference scan (CT scan or vascular sonographer-performed ultrasound). Reference scans were completed within 3 months of the recruitment visit. A total of 57 patients were enrolled over a 5-month period between October 2015 and March 2016. Mean age of recruited patients was 71 years and 61% were male. Mean body mass index was 27.9 ± 4.3 and mean waist-hip ratio was 0.96 ± 0.10. Sixteen abdominal aortic aneurysms were detected by the reference scan, with an average maximal aortic diameter of 44.9 mm. Physical examination by a vascular surgeon detected 11 of 16 abdominal aortic aneurysms with 2 false positives (sensitivity and specificity of 66.7% (95% CI 38.4-88.2) and 94.4% (95% CI 81.3-99.3), respectively). Point-of-care ultrasound detected 15 of 16 abdominal aortic aneurysms (sensitivity and specificity of 93.3% (95% CI 68.1-99.8) and 100% (95% CI 88.4-100), respectively). Seven of the 64 point-of-care ultrasound scans were indeterminate (>1 cm of the aorta was not visualized). Average time to conduct the physical examination was 35 seconds vs. 4.0 minutes for point-of-care ultrasonography. There was a

  19. Integrated electrochemical microsystems for genetic detection of pathogens at the point of care.

    PubMed

    Hsieh, Kuangwen; Ferguson, B Scott; Eisenstein, Michael; Plaxco, Kevin W; Soh, H Tom

    2015-04-21

    The capacity to achieve rapid, sensitive, specific, quantitative, and multiplexed genetic detection of pathogens via a robust, portable, point-of-care platform could transform many diagnostic applications. And while contemporary technologies have yet to effectively achieve this goal, the advent of microfluidics provides a potentially viable approach to this end by enabling the integration of sophisticated multistep biochemical assays (e.g., sample preparation, genetic amplification, and quantitative detection) in a monolithic, portable device from relatively small biological samples. Integrated electrochemical sensors offer a particularly promising solution to genetic detection because they do not require optical instrumentation and are readily compatible with both integrated circuit and microfluidic technologies. Nevertheless, the development of generalizable microfluidic electrochemical platforms that integrate sample preparation and amplification as well as quantitative and multiplexed detection remains a challenging and unsolved technical problem. Recognizing this unmet need, we have developed a series of microfluidic electrochemical DNA sensors that have progressively evolved to encompass each of these critical functionalities. For DNA detection, our platforms employ label-free, single-step, and sequence-specific electrochemical DNA (E-DNA) sensors, in which an electrode-bound, redox-reporter-modified DNA "probe" generates a current change after undergoing a hybridization-induced conformational change. After successfully integrating E-DNA sensors into a microfluidic chip format, we subsequently incorporated on-chip genetic amplification techniques including polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) to enable genetic detection at clinically relevant target concentrations. To maximize the potential point-of-care utility of our platforms, we have further integrated sample preparation via immunomagnetic separation, which

  20. Mathematics Competency for Beginning Chemistry Students Through Dimensional Analysis.

    PubMed

    Pursell, David P; Forlemu, Neville Y; Anagho, Leonard E

    2017-01-01

    Mathematics competency in nursing education and practice may be addressed by an instructional variation of the traditional dimensional analysis technique typically presented in beginning chemistry courses. The authors studied 73 beginning chemistry students using the typical dimensional analysis technique and the variation technique. Student quantitative problem-solving performance was evaluated. Students using the variation technique scored significantly better (18.3 of 20 points, p < .0001) on the final examination quantitative titration problem than those who used the typical technique (10.9 of 20 points). American Chemical Society examination scores and in-house assessment indicate that better performing beginning chemistry students were more likely to use the variation technique rather than the typical technique. The variation technique may be useful as an alternative instructional approach to enhance beginning chemistry students' mathematics competency and problem-solving ability in both education and practice. [J Nurs Educ. 2017;56(1):22-26.]. Copyright 2017, SLACK Incorporated.

  1. Health care costs: the other point of view.

    PubMed

    Beck, D F; Dempsey, J

    1990-12-01

    Health care delivery in America is not efficient. Hospitals are not efficient and many are still wasteful. Some of the most blatant wastes in hospitals are staffing patterns that developed during the years of cost reports. Spending patterns become the norm, rather than excess, when they continue unabated for years. There are many reasons for cost increases in health care and specifically in hospitals. However, it is difficult to make these reasons add up to the total cost increase. No one has the answers; observation can only be made of what has been occurring and what continues to occur. Whatever the reason for the increase in health care costs, the consumer will bear the burden because of the circular flow of income and expenditures between the business sector and the household sector. Increased health care costs are passed on to the consumer in the form of increased expenditures for household goods and services or taxes. Ford Motor Company President Mr. Peterson says that $1,500 of every new automobile represents employee health care costs. The American consumer created the demand for health care services, and only the consumer can control the demand. One solution would be to let the consumer bear health care costs directly and remove the inefficiencies created by third party insurance carriers. This hypothesizes that the health care consumer is the most efficient shopper for health care services, and that third party insurance carriers are an important source of inefficiency in the health care delivery system. Many other solutions have been proposed by the government and by the insurance and health care industries, but most have only increased the cost of health care. Perhaps some day the health care industry will learn how to control the dynamics of this four-party purchasing decision. Until then, costs will continue to grow dramatically, and the executives of the industries who compete in the two-party purchasing system will wonder why the process is so

  2. Point-of-care ultrasound education: the increasing role of simulation and multimedia resources.

    PubMed

    Lewiss, Resa E; Hoffmann, Beatrice; Beaulieu, Yanick; Phelan, Mary Beth

    2014-01-01

    This article reviews the current technology, literature, teaching models, and methods associated with simulation-based point-of-care ultrasound training. Patient simulation appears particularly well suited for learning point-of-care ultrasound, which is a required core competency for emergency medicine and other specialties. Work hour limitations have reduced the opportunities for clinical practice, and simulation enables practicing a skill multiple times before it may be used on patients. Ultrasound simulators can be categorized into 2 groups: low and high fidelity. Low-fidelity simulators are usually static simulators, meaning that they have nonchanging anatomic examples for sonographic practice. Advantages are that the model may be reused over time, and some simulators can be homemade. High-fidelity simulators are usually high-tech and frequently consist of many computer-generated cases of virtual sonographic anatomy that can be scanned with a mock probe. This type of equipment is produced commercially and is more expensive. High-fidelity simulators provide students with an active and safe learning environment and make a reproducible standardized assessment of many different ultrasound cases possible. The advantages and disadvantages of using low- versus high-fidelity simulators are reviewed. An additional concept used in simulation-based ultrasound training is blended learning. Blended learning may include face-to-face or online learning often in combination with a learning management system. Increasingly, with simulation and Web-based learning technologies, tools are now available to medical educators for the standardization of both ultrasound skills training and competency assessment.

  3. Miniaturization for Point-of-Care Analysis: Platform Technology for Almost Every Biomedical Assay.

    PubMed

    Schumacher, Soeren; Sartorius, Dorian; Ehrentreich-Förster, Eva; Bier, Frank F

    2012-10-01

    Platform technologies for the changing need of diagnostics are one of the main challenges in medical device technology. From one point-of-view the demand for new and more versatile diagnostic is increasing due to a deeper knowledge of biomarkers and their combination with diseases. From another point-of-view a decentralization of diagnostics will occur since decisions can be made faster resulting in higher success of therapy. Hence, new types of technologies have to be established which enables a multiparameter analysis at the point-of-care. Within this review-like article a system called Fraunhofer ivD-platform is introduced. It consists of a credit-card sized cartridge with integrated reagents, sensors and pumps and a read-out/processing unit. Within the cartridge the assay runs fully automated within 15-20 minutes. Due to the open design of the platform different analyses such as antibody, serological or DNA-assays can be performed. Specific examples of these three different assay types are given to show the broad applicability of the system.

  4. Pre-implementation guidelines for infectious disease point-of-care testing in medical institutions.

    PubMed

    van der Eijk, Annemiek A; Tintu, Andrei N; Hays, John P

    2017-01-01

    Infectious disease point-of-care test (ID-POCT) devices are becoming widely available, and in this respect, international quality standards and guidelines are available for consultation once ID-POCT has been implemented into medical institutions. However, specific guidelines for consultation during the initial pre-implementation decision-making process are currently lacking. Further, there exist pre-implementation issues specific to ID-POCT. Here we present pre-implementation guidelines for consultation when considering the implementation of ID-POCT in medical institutions.

  5. Perceptions of point-of-care infectious disease testing among European medical personnel, point-of-care test kit manufacturers, and the general public.

    PubMed

    Kaman, Wendy E; Andrinopoulou, Eleni-Rosalina; Hays, John P

    2013-01-01

    The proper development and implementation of point-of-care (POC) diagnostics requires knowledge of the perceived requirements and barriers to their implementation. To determine the current requirements and perceived barriers to the introduction of POC diagnostics in the field of medical microbiology (MM)-POC a prospective online survey (TEMPOtest-QC) was established. The TEMPOtest-QC survey was online between February 2011 and July 2012 and targeted the medical community, POC test diagnostic manufacturers, general practitioners, and the general public. In total, 293 individuals responded to the survey, including 91 (31%) medical microbiologists, 39 (13%) nonmedical microbiologists, 25 (9%) employees of POC test manufacturers, and 138 (47%) members of the general public. Responses were received from 18 different European countries, with the largest percentage of these living in The Netherlands (52%). The majority (>50%) of medical specialists regarded the development of MM-POC for blood culture and hospital acquired infections as "absolutely necessary", but were much less favorable towards their use in the home environment. Significant differences in perceptions between medical specialists and the general public included the: (1) Effect on quality of patient care; (2) Ability to better monitor patients; (3) Home testing and the doctor-patient relationship; and (4) MM-POC interpretation. Only 34.7% of the general public is willing to pay more than a€10 ($13) for a single MM-POC test, with 85.5% preferring to purchase their MM-POC test from a pharmacy. The requirements for the proper implementation of MM-POC were found to be generally similar between medical specialists and POC test kit manufacturers. The general public was much more favorable with respect to a perceived improvement in the quality of healthcare that these tests would bring to the hospital and home environment.

  6. A Perspective on Physical Organic Chemistry

    PubMed Central

    2015-01-01

    A perspective on the development of mechanistic carbene chemistry is presented. The author will point out questions that have been answered, and a next generation of questions will be proposed. PMID:24571434

  7. The Value of Clinical Needs Assessments for Point-of-Care Diagnostics

    PubMed Central

    Weigl, Bernhard H.; Gaydos, Charlotte A.; Kost, Gerald; Beyette, Fred R.; Sabourin, Stephanie; Rompalo, Anne; de los Santos, Tala; McMullan, Jason T.; Haller, John

    2013-01-01

    Most entrepreneurial ventures fail long before the core technology can be brought to the marketplace because of disconnects in performance and usability measures such as accuracy, cost, complexity, assay stability, and time requirements between technology developers’ specifications and needs of the end-users. By going through a clinical needs assessment (CNA) process, developers will gain vital information and a clear focus that will help minimize the risks associated with the development of new technologies available for use within the health care system. This article summarizes best practices of the principal investigators of the National Institute of Biomedical Imaging and Bioengineering point-of-care (POC) centers within the National Institute of Biomedical Imaging and Bioengineering POC Technologies Research Network. Clinical needs assessments are particularly important for product development areas that do not sufficiently benefit from traditional market research, such as grant-funded research and development, new product lines using cutting-edge technologies developed in start-up companies, and products developed through product development partnerships for low-resource settings. The objectives of this article were to (1) highlight the importance of CNAs for development of POC devices, (2) discuss methods applied by POC Technologies Research Network for assessing clinical needs, and (3) provide a road map for future CNAs. PMID:23935405

  8. Towards microfluidic reactors for cell-free protein synthesis at the point-of-care

    DOE PAGES

    Timm, Andrea C.; Shankles, Peter G.; Foster, Carmen M.; ...

    2015-12-22

    Cell-free protein synthesis (CFPS) is a powerful technology that allows for optimization of protein production without maintenance of a living system. Integrated within micro- and nano-fluidic architectures, CFPS can be optimized for point-of care use. Here, we describe the development of a microfluidic bioreactor designed to facilitate the production of a single-dose of a therapeutic protein, in a small footprint device at the point-of-care. This new design builds on the use of a long, serpentine channel bioreactor and is enhanced by integrating a nanofabricated membrane to allow exchange of materials between parallel reactor and feeder channels. This engineered membrane facilitatesmore » the exchange of metabolites, energy, and inhibitory species, prolonging the CFPS reaction and increasing protein yield. Membrane permeability can be altered by plasma-enhanced chemical vapor deposition and atomic layer deposition to tune the exchange rate of small molecules. This allows for extended reaction times and improved yields. Further, the reaction product and higher molecular weight components of the transcription/translation machinery in the reactor channel can be retained. As a result, we show that the microscale bioreactor design produces higher protein yields than conventional tube-based batch formats, and that product yields can be dramatically improved by facilitating small molecule exchange within the dual-channel bioreactor.« less

  9. Towards microfluidic reactors for cell-free protein synthesis at the point-of-care

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timm, Andrea C.; Shankles, Peter G.; Foster, Carmen M.

    Cell-free protein synthesis (CFPS) is a powerful technology that allows for optimization of protein production without maintenance of a living system. Integrated within micro- and nano-fluidic architectures, CFPS can be optimized for point-of care use. Here, we describe the development of a microfluidic bioreactor designed to facilitate the production of a single-dose of a therapeutic protein, in a small footprint device at the point-of-care. This new design builds on the use of a long, serpentine channel bioreactor and is enhanced by integrating a nanofabricated membrane to allow exchange of materials between parallel reactor and feeder channels. This engineered membrane facilitatesmore » the exchange of metabolites, energy, and inhibitory species, prolonging the CFPS reaction and increasing protein yield. Membrane permeability can be altered by plasma-enhanced chemical vapor deposition and atomic layer deposition to tune the exchange rate of small molecules. This allows for extended reaction times and improved yields. Further, the reaction product and higher molecular weight components of the transcription/translation machinery in the reactor channel can be retained. As a result, we show that the microscale bioreactor design produces higher protein yields than conventional tube-based batch formats, and that product yields can be dramatically improved by facilitating small molecule exchange within the dual-channel bioreactor.« less

  10. Access to point-of-care tests reduces the prescription of antibiotics among antibiotic-requesting subjects with respiratory tract infections.

    PubMed

    Llor, Carl; Bjerrum, Lars; Munck, Anders; Cots, Josep M; Hernández, Silvia; Moragas, Ana

    2014-12-01

    General practitioners (GPs) often feel uncomfortable when patients request an antibiotic when there is likely little benefit. This study evaluates the effect of access to point-of-care tests on decreasing the prescription of antibiotics in respiratory tract infections in subjects who explicitly requested an antibiotic prescription. Spanish GPs registered all cases of respiratory tract infections over a 3-week period before and after an intervention undertaken in 2008 and 2009. Patients with acute sinusitis, pneumonia, and exacerbations of COPD were excluded. Two types of interventions were performed: the full intervention group received prescriber feedback with discussion of the results of the first registry, courses for GPs, guidelines, patient information leaflets, workshops, and access to point-of-care tests (rapid streptococcal antigen detection test and C-reactive protein test); and the partial intervention group underwent all of the above interventions except for the workshop and access to point-of-care tests. A total of 210 GPs were assigned to the full intervention group and 71 to the partial intervention group. A total of 25,479 subjects with respiratory tract infections were included, of whom 344 (1.4%) requested antibiotic prescribing. Antibiotics were more frequently prescribed to subjects requesting them compared with those who did not (49.1% vs 18.5%, P < .001). In the group of GPs assigned to the partial intervention group, 53.1% of subjects requesting antibiotics received a prescription before and 60% after the intervention, without statistical differences being observed. In the group of GPs assigned to the full intervention group, the percentages were 55.1% and 36.2%, respectively, with a difference of 18.9% (95% CI: 6.4%-30.6%, P < .05). Access to point-of-care tests reduces antibiotic use in subjects who explicitly request an antibiotic prescription. Copyright © 2014 by Daedalus Enterprises.

  11. Development and validation of a noncontact spectroscopic device for hemoglobin estimation at point-of-care

    NASA Astrophysics Data System (ADS)

    Sarkar, Probir Kumar; Pal, Sanchari; Polley, Nabarun; Aich, Rajarshi; Adhikari, Aniruddha; Halder, Animesh; Chakrabarti, Subhananda; Chakrabarti, Prantar; Pal, Samir Kumar

    2017-05-01

    Anemia severely and adversely affects human health and socioeconomic development. Measuring hemoglobin with the minimal involvement of human and financial resources has always been challenging. We describe a translational spectroscopic technique for noncontact hemoglobin measurement at low-resource point-of-care settings in human subjects, independent of their skin color, age, and sex, by measuring the optical spectrum of the blood flowing in the vascular bed of the bulbar conjunctiva. We developed software on the LabVIEW platform for automatic data acquisition and interpretation by nonexperts. The device is calibrated by comparing the differential absorbance of light of wavelength 576 and 600 nm with the clinical hemoglobin level of the subject. Our proposed method is consistent with the results obtained using the current gold standard, the automated hematology analyzer. The proposed noncontact optical device for hemoglobin estimation is highly efficient, inexpensive, feasible, and extremely useful in low-resource point-of-care settings. The device output correlates with the different degrees of anemia with absolute and trending accuracy similar to those of widely used invasive methods. Moreover, the device can instantaneously transmit the generated report to a medical expert through e-mail, text messaging, or mobile apps.

  12. Advances in addressing technical challenges of point-of-care diagnostics in resource-limited settings

    PubMed Central

    Wang, ShuQi; Lifson, Mark A.; Inci, Fatih; Liang, Li-Guo; Sheng, Ye-Feng; Demirci, Utkan

    2016-01-01

    The striking prevalence of HIV, TB and malaria, as well as outbreaks of emerging infectious diseases, such as influenza A (H7N9), Ebola and MERS, poses great challenges for patient care in resource-limited settings (RLS). However, advanced diagnostic technologies cannot be implemented in RLS largely due to economic constraints. Simple and inexpensive point-of-care (POC) diagnostics, which rely less on environmental context and operator training, have thus been extensively studied to achieve early diagnosis and treatment monitoring in non-laboratory settings. Despite great input from material science, biomedical engineering and nanotechnology for developing POC diagnostics, significant technical challenges are yet to be overcome. Summarized here are the technical challenges associated with POC diagnostics from a RLS perspective and the latest advances in addressing these challenges are reviewed. PMID:26777725

  13. Sexual health risks, service use, and views of rapid point-of-care testing among men who have sex with men attending saunas: a cross-sectional survey.

    PubMed

    Horwood, Jeremy; Ingle, Suzanne M; Burton, David; Woodman-Bailey, Adam; Horner, Paddy; Jeal, Nikki

    2016-03-01

    Guidelines highlight the need to increase HIV testing among men who have sex with men (MSM) and novel point-of-care testing provides new possibilities for delivery of care. However, it is unclear how point-of-care testing should be used to best effect. This study aimed to increase understanding of sexual risk-taking behaviour, service use, and attitudes to point-of-care testing among MSM sauna clients. Data were collected within two saunas for MSM in south west England using a self-completion survey (n = 134). Though this sample of MSM sauna clients are at high risk of acquiring a sexually transmitted infection, the testing frequency among the majority of those reporting unprotected anal intercourse is not in keeping with national guidelines. For almost all participants the introduction of rapid point-of-care testing for both genital and blood-borne infection was likely to increase testing and for the majority NHS specialist services was the preferred setting. © The Author(s) 2016.

  14. Sexual health risks, service use, and views of rapid point-of-care testing among men who have sex with men attending saunas: a cross-sectional survey

    PubMed Central

    Horwood, Jeremy; Ingle, Suzanne M; Burton, David; Woodman-Bailey, Adam; Horner, Paddy

    2015-01-01

    Guidelines highlight the need to increase HIV testing among men who have sex with men (MSM) and novel point-of-care testing provides new possibilities for delivery of care. However, it is unclear how point-of-care testing should be used to best effect. This study aimed to increase understanding of sexual risk-taking behaviour, service use, and attitudes to point-of-care testing among MSM sauna clients. Data were collected within two saunas for MSM in south west England using a self-completion survey (n = 134). Though this sample of MSM sauna clients are at high risk of acquiring a sexually transmitted infection, the testing frequency among the majority of those reporting unprotected anal intercourse is not in keeping with national guidelines. For almost all participants the introduction of rapid point-of-care testing for both genital and blood-borne infection was likely to increase testing and for the majority NHS specialist services was the preferred setting. PMID:25907347

  15. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    NASA Astrophysics Data System (ADS)

    Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter

    2015-03-01

    We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.

  16. Magic, science and masculinity: marketing toy chemistry sets.

    PubMed

    Al-Gailani, Salim

    2009-12-01

    At least since the late nineteenth century, toy chemistry sets have featured in standard scripts of the achievement of eminence in science, and they remain important in constructions of scientific identity. Using a selection of these toys manufactured in Britain and the United States, and with particular reference to the two dominant American brands, Gilbert and Chemcraft, this paper suggests that early twentieth-century chemistry sets were rooted in overlapping Victorian traditions of entertainment magic and scientific recreations. As chemistry set marketing copy gradually reoriented towards emphasising scientific modernity, citizenship, discipline and educational value, pre-twentieth-century traditions were subsumed within domestic-and specifically masculine-tropes. These developments in branding strategies point to transformations in both users' engagement with their chemistry sets and the role of scientific toys in domestic play. The chemistry set serves here as a useful tool for measuring cultural change and lay engagement with chemistry.

  17. Evaluation of Point-of-Care Resources for Dietary Supplement Information.

    PubMed

    Montgomery, Ashley E; Beckett, Robert D; Montagano, Kaitlin J; Kutom, Samah

    2018-01-01

    To evaluate 6 tertiary, point-of-care drug information resources' dietary supplement content. This was a cross-sectional evaluation of Lexicomp Natural Products Database, Micromedex Alternative Medicine, Clinical Pharmacology, Natural Medicines, The Review of Natural Products, and Handbook of Nonprescription Drugs. Each resource was evaluated for scope, completeness, consistency, and ease of use. For a sample of 66 supplements, scope scores ranged from 69.7% (Micromedex) to 100% (Natural Medicines). Completeness scores were high considering uses, dose, adverse effects, and mechanism (85.7% to 100%). Overall completeness scores ranged from 82.5% ( Handbook of Nonprescription Drugs) to 100% (Clinical Pharmacology, Natural Medicines, The Review of Natural Products). Consistency scores ranged from 0% ( Handbook of Nonprescription Drugs) to 100% (Natural Medicines, The Review of Natural Products). Mean time to locate and gather information was similar among groups. Resources were similar for completeness and ease of use. Scope and consistency varied depending on the resource.

  18. The role of point of care ultrasound in prehospital critical care: a systematic review.

    PubMed

    Bøtker, Morten Thingemann; Jacobsen, Lars; Rudolph, Søren Steemann; Knudsen, Lars

    2018-06-26

    In 2011, the role of Point of Care Ultrasound (POCUS) was defined as one of the top five research priorities in physician-provided prehospital critical care and future research topics were proposed; the feasibility of prehospital POCUS, changes in patient management induced by POCUS and education of providers. This systematic review aimed to assess these three topics by including studies examining all kinds of prehospital patients undergoing all kinds of prehospital POCUS examinations and studies examining any kind of POCUS education in prehospital critical care providers. By a systematic literature search in MEDLINE, EMBASE, and Cochrane databases, we identified and screened titles and abstracts of 3264 studies published from 2012 to 2017. Of these, 65 studies were read in full-text for assessment of eligibility and 27 studies were ultimately included and assessed for quality by SIGN-50 checklists. No studies compared patient outcome with and without prehospital POCUS. Four studies of acceptable quality demonstrated feasibility and changes in patient management in trauma. Two studies of acceptable quality demonstrated feasibility and changes in patient management in breathing difficulties. Four studies of acceptable quality demonstrated feasibility, outcome prediction and changes in patient management in cardiac arrest, but also that POCUS may prolong pauses in compressions. Two studies of acceptable quality demonstrated that short (few hours) teaching sessions are sufficient for obtaining simple interpretation skills, but not image acquisition skills. Three studies of acceptable quality demonstrated that longer one- or two-day courses including hands-on training are sufficient for learning simple, but not advanced, image acquisition skills. Three studies of acceptable quality demonstrated that systematic educational programs including supervised examinations are sufficient for learning advanced image acquisition skills in healthy volunteers, but that more than 50

  19. Streaming fragment assignment for real-time analysis of sequencing experiments

    PubMed Central

    Roberts, Adam; Pachter, Lior

    2013-01-01

    We present eXpress, a software package for highly efficient probabilistic assignment of ambiguously mapping sequenced fragments. eXpress uses a streaming algorithm with linear run time and constant memory use. It can determine abundances of sequenced molecules in real time, and can be applied to ChIP-seq, metagenomics and other large-scale sequencing data. We demonstrate its use on RNA-seq data, showing greater efficiency than other quantification methods. PMID:23160280

  20. Exploiting Locality in Quantum Computation for Quantum Chemistry.

    PubMed

    McClean, Jarrod R; Babbush, Ryan; Love, Peter J; Aspuru-Guzik, Alán

    2014-12-18

    Accurate prediction of chemical and material properties from first-principles quantum chemistry is a challenging task on traditional computers. Recent developments in quantum computation offer a route toward highly accurate solutions with polynomial cost; however, this solution still carries a large overhead. In this Perspective, we aim to bring together known results about the locality of physical interactions from quantum chemistry with ideas from quantum computation. We show that the utilization of spatial locality combined with the Bravyi-Kitaev transformation offers an improvement in the scaling of known quantum algorithms for quantum chemistry and provides numerical examples to help illustrate this point. We combine these developments to improve the outlook for the future of quantum chemistry on quantum computers.

  1. Point-of-Care Viral Load Testing for Sub-Saharan Africa: Informing a Target Product Profile.

    PubMed

    Phillips, Andrew N; Cambiano, Valentina; Nakagawa, Fumiyo; Ford, Deborah; Apollo, Tsitsi; Murungu, Joseph; Rousseau, Christine; Garnett, Geoff; Ehrenkranz, Peter; Bansi-Matharu, Loveleen; Vojnov, Lara; Katz, Zachary; Peeling, Rosanna; Revill, Paul

    2016-09-01

    Point-of-care viral load tests are being developed to monitor patients on antiretroviral therapy (ART) in sub-Saharan Africa. Test design involves trade-offs between test attributes, including accuracy, complexity, robustness, and cost. We used a model of the human immunodeficiency virus epidemic and ART program in Zimbabwe and found that the attributes of a viral load testing approach that are most influential for cost effectiveness are avoidance of a high proportion of failed tests or results not received, use of an approach that best facilitates retention on ART, and the ability to facilitate greater use of differentiated care, including through expanding coverage of testing availability.

  2. Point-of-Care Viral Load Testing for Sub-Saharan Africa: Informing a Target Product Profile

    PubMed Central

    Phillips, Andrew N.; Cambiano, Valentina; Nakagawa, Fumiyo; Ford, Deborah; Apollo, Tsitsi; Murungu, Joseph; Rousseau, Christine; Garnett, Geoff; Ehrenkranz, Peter; Bansi-Matharu, Loveleen; Vojnov, Lara; Katz, Zachary; Peeling, Rosanna; Revill, Paul

    2016-01-01

    Point-of-care viral load tests are being developed to monitor patients on antiretroviral therapy (ART) in sub-Saharan Africa. Test design involves trade-offs between test attributes, including accuracy, complexity, robustness, and cost. We used a model of the human immunodeficiency virus epidemic and ART program in Zimbabwe and found that the attributes of a viral load testing approach that are most influential for cost effectiveness are avoidance of a high proportion of failed tests or results not received, use of an approach that best facilitates retention on ART, and the ability to facilitate greater use of differentiated care, including through expanding coverage of testing availability. PMID:27704016

  3. The Ebola Spatial Care Path™: Accelerating point-of-care diagnosis, decision making, and community resilience in outbreaks.

    PubMed

    Kost, Gerald J; Ferguson, William J; Hoe, Jackie; Truong, Anh-Thu; Banpavichit, Arirat; Kongpila, Surin

    2015-01-01

    To present a vision where point-of-care testing (POCT) accelerates an Ebola Spatial Care Path™ (SCP) and future molecular diagnostics enable facilitated-access self-testing (FAST POC); to design an alternate care facility (ACF) for the SCP; to innovate an Ebola diagnostic center (DC); and to propel rapid POCT to the frontline to create resilience that stops future outbreaks. PubMed, literature, and web searches. Centers for Disease Control and Prevention (CDC), Food and Drug Administration (FDA), Medicine Without Frontiers, and World Health Organization (WHO) document analyses. Investigations in China, the Philippines, Thailand, and the United States. Review of SE Asia, US, and West Africa isolation-treatment centers. Innovation of a SCP, ACF, and DC suitable for American and other communities. The authors designed an ACF and DC to integrate SCP principles for urgent Ebola care. FDA emergency use authorizations for Ebola molecular diagnostics were discovered, but no portable, handheld, or self-contained molecular POC instruments are yet available, although feasible. The WHO initiated design criteria and an acceptance protocol for testing. Financial investment in POCT will downsize Ebola outbreaks. POCT is facilitating global health. Now, global health problems are elevating POCT to new levels of importance for accelerating diagnosis and evidence-based decision making during disease outbreaks. Authorities concur that rapid diagnosis has potential to stop disease spread. With embedded POCT, strategic SCPs planned by communities fulfill CDC recommendations. POC devices should consolidate multiplex test clusters supporting patients with Ebola in isolation. The ultimate future solution is FAST POC. New technologies offer minimally significant risks. Diagnostic centers in ACFs and transportable formats also will optimize Ebola SCPs.

  4. International Image Concordance Study to Compare a Point of Care Tampon Colposcope to a Standard-of-Care Colposcope

    PubMed Central

    Mueller, Jenna L.; Asma, Elizabeth; Lam, Christopher T.; Krieger, Marlee S.; Gallagher, Jennifer E.; Erkanli, Alaattin; Hariprasad, Roopa; Malliga, J.S.; Muasher, Lisa C.; Mchome, Bariki; Oneko, Olola; Taylor, Peyton; Venegas, Gino; Wanyoro, Anthony; Mehrotra, Ravi; Schmitt, John W.; Ramanujam, Nimmi

    2017-01-01

    Objective Barriers to cervical cancer screening in low resource settings include lack of accessible high quality services, high cost, and the need for multiple visits. To address these challenges, we developed a low cost intra-vaginal optical cervical imaging device, the Point of Care Tampon (POCkeT) colposcope, and evaluated whether its performance is comparable to a standard-of-care colposcope. Methods There were two protocols, which included 44 and 18 patients respectively. For the first protocol, white light cervical images were collected in vivo, blinded by device, and sent electronically to 8 physicians from high, middle and low income countries. For the second protocol, green light images were also collected and sent electronically to the highest performing physician from the first protocol who has experience in both a high and low income country. For each image, physicians completed a survey assessing cervix characteristics and severity of precancerous lesions. Corresponding pathology was obtained for all image pairs. Results For the first protocol, average percent agreement between devices was 70% across all physicians. POCkeT and standard-of-care colposcope images had 37% and 51% percent agreement respectively with pathology for high-grade squamous intraepithelial lesions (HSILs). Investigation of HSIL POCkeT images revealed decreased visibility of vascularization and lack of contrast in lesion margins. After changes were made for the second protocol, the two devices achieved similar agreement to pathology for HSIL lesions (55%). Conclusions Based on the exploratory study, physician interpretation of cervix images acquired using a portable, low cost, POCkeT colposcope was comparable to a standard-of-care colposcope. PMID:28263237

  5. Progression from on-site to point-of-care fine needle aspiration service: Opportunities and challenges

    PubMed Central

    Gupta, Prabodh K

    2010-01-01

    Background Standard-of-care requires the availability of an efficient, economical and accurate on-site fine needle aspiration (FNA) service. Presence of a trained individual during the procedure ensures an improved patient care. Appropriate selection of the equipment, interaction with the clinicians and compliance with the various regulations during the procedure is essential. This is often done by an on-site FNA service. Organization and implementation of such a system in a large academic center is challenging. Method we reviewed the ambulatory care needs in the new Perelman Center for Advanced Medicine (PeCAM). Multiple (9) FNA sites have been established keeping in view the patient's convenience, clinic demands, various regulatory requirements and laboratory staff. Each location has dedicated FNA station with microscopes and supplies. In addition, state- ofthe -art technologies including a mobile FNA cart (Penn-A- Cart), remote specimen evaluation (TeleCyP) have been incorporated. Results The new set up is extremely efficient and much valued by the patients and the clinicians. It has improved patient care. Conclusion With necessary investments and resources a point-of-care FNA service has been created which has improved patient care. This, albeit with certain modifications may serve as a model for FNA service. PMID:20607093

  6. Practical challenges related to point of care testing.

    PubMed

    Shaw, Julie L V

    2016-04-01

    Point of care testing (POCT) refers to laboratory testing that occurs near to the patient, often at the patient bedside. POCT can be advantageous in situations requiring rapid turnaround time of test results for clinical decision making. There are many challenges associated with POCT, mainly related to quality assurance. POCT is performed by clinical staff rather than laboratory trained individuals which can lead to errors resulting from a lack of understanding of the importance of quality control and quality assurance practices. POCT is usually more expensive than testing performed in the central laboratory and requires a significant amount of support from the laboratory to ensure the quality testing and meet accreditation requirements. Here, specific challenges related to POCT compliance with accreditation standards are discussed along with strategies that can be used to overcome these challenges. These areas include: documentation of POCT orders, charting of POCT results as well as training and certification of individuals performing POCT. Factors to consider when implementing connectivity between POCT instruments and the electronic medical record are also discussed in detail and include: uni-directional versus bidirectional communication, linking patient demographic information with POCT software, the importance of positive patient identification and considering where to chart POCT results in the electronic medical record.

  7. The RATPAC (Randomised Assessment of Treatment using Panel Assay of Cardiac markers) trial: a randomised controlled trial of point-of-care cardiac markers in the emergency department.

    PubMed

    Goodacre, S; Bradburn, M; Fitzgerald, P; Cross, E; Collinson, P; Gray, A; Hall, A S

    2011-05-01

    To evaluate the clinical effectiveness and cost-effectiveness of using a point-of-care cardiac marker panel in patients presenting to the emergency department (ED) with suspected but not proven acute myocardial infarction (AMI). Multicentre pragmatic open randomised controlled trial and economic evaluation. Six acute hospital EDs in the UK. Adults presenting to hospital with chest pain due to suspected but not proven myocardial infarction, and no other potentially serious alternative pathology or comorbidity. Participants were allocated using an online randomisation system to receive either (1) diagnostic assessment using the point-of-care biochemical marker panel or (2) conventional diagnostic assessment without the panel. All tests and treatments other than the panel were provided at the discretion of the clinician. The primary outcome was the proportion of patients successfully discharged home after ED assessment, defined as patients who had (1) either left the hospital or were awaiting transport home with a discharge decision having been made at 4 hours after initial presentation and (2) suffered no major adverse event (as defined below) during the following 3 months. Secondary outcomes included length of initial hospital stay and total inpatient days over 3 months, and major adverse events (death, non-fatal AMI, life-threatening arrhythmia, emergency revascularisation or hospitalisation for myocardial ischaemia). Economic analysis estimated mean costs and quality-adjusted life-years (QALYs), and then estimated the probability of cost-effectiveness assuming willingness to pay of £20,000 per QALY gained. We randomised 1132 participants to point of care and 1131 to standard care, and analysed 1125 and 1118, respectively [mean age 54.5 years, 1307/2243 (58%) male and 269/2243 (12%) with known coronary heart disease (CHD)]. In the point-of-care group 358/1125 (32%) were successfully discharged compared with 146/1118 (13%) in the standard-care group [odds ratio (OR

  8. Analytical Chemistry: A Literary Approach

    NASA Astrophysics Data System (ADS)

    Lucy, Charles A.

    2000-04-01

    The benefits of incorporating real-world examples of chemistry into lectures and lessons is reflected by the recent inclusion of the Teaching with Problems and Case Studies column in this Journal. However, these examples lie outside the experience of many students, and so much of the impact of "real-world" examples is lost. This paper provides an anthology of references to analytical chemistry techniques from history, popular fiction, and film. Such references are amusing to both instructor and student. Further, the fictional descriptions can serve as a focal point for discussions of a technique's true capabilities and limitations.

  9. Criteria required for an acceptable point-of-care test for UTI detection: Obtaining consensus using the Delphi technique.

    PubMed

    Weir, Nichola-Jane M; Pattison, Sally H; Kearney, Paddy; Stafford, Bob; Gormley, Gerard J; Crockard, Martin A; Gilpin, Deirdre F; Tunney, Michael M; Hughes, Carmel M

    2018-01-01

    Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test.

  10. Point-of-Care Quantitative Measure of Glucose-6-Phosphate Dehydrogenase Enzyme Deficiency.

    PubMed

    Bhutani, Vinod K; Kaplan, Michael; Glader, Bertil; Cotten, Michael; Kleinert, Jairus; Pamula, Vamsee

    2015-11-01

    Widespread newborn screening on a point-of-care basis could prevent bilirubin neurotoxicity in newborns with glucose-6-phosphate dehydrogenase (G6PD) deficiency. We evaluated a quantitative G6PD assay on a digital microfluidic platform by comparing its performance with standard clinical methods. G6PD activity was measured quantitatively by using digital microfluidic fluorescence and the gold standard fluorescence biochemical test on a convenience sample of 98 discarded blood samples. Twenty-four samples were designated as G6PD deficient. Mean ± SD G6PD activity for normal samples using the digital microfluidic method and the standard method, respectively, was 9.7 ± 2.8 and 11.1 ± 3.0 U/g hemoglobin (Hb), respectively; for G6PD-deficient samples, it was 0.8 ± 0.7 and 1.4 ± 0.9 U/g Hb. Bland-Altman analysis determined a mean difference of -0.96 ± 1.8 U/g Hb between the digital microfluidic fluorescence results and the standard biochemical test results. The lower and upper limits for the digital microfluidic platform were 4.5 to 19.5 U/g Hb for normal samples and 0.2 to 3.7 U/g Hb for G6PD-deficient samples. The lower and upper limits for the Stanford method were 5.5 to 20.7 U/g Hb for normal samples and 0.1 to 2.8 U/g Hb for G6PD-deficient samples. The measured activity discriminated between G6PD-deficient samples and normal samples with no overlap. Pending further validation, a digital microfluidics platform could be an accurate point-of-care screening tool for rapid newborn G6PD screening. Copyright © 2015 by the American Academy of Pediatrics.

  11. Accuracy, user-friendliness and usefulness of the Cobas h232 point-of-care test for NT-proBNP in primary care.

    PubMed

    Hex, Chiel; Smeets, Miek; Penders, Joris; Van Hoof, Viviane; Verbakel, Jan; Buntinx, Frank; Vaes, Bert

    2018-06-01

    N-terminal pro-B-type natriuretic peptide (NT-proBNP) has been shown to be useful for ruling out heart failure in primary care. In this study, we examined the accuracy of the Cobas h232 point-of-care (POC) instrument in primary care compared with an in-hospital measurement. Furthermore, we investigated the user-friendliness and usefulness of the POC device. Five general practitioner (GP) groups were asked to evaluate adult patients who were suspected of having heart failure and to test NT-proBNP with the Cobas h232. The samples were subsequently delivered to and analysed at a central hospital laboratory by the Cobas e602 using conventional transport and storage. Difference between the paired measurements was analysed using a percentage difference plot, and correlation was assessed using Passing-Bablok linear regression analysis. User-friendliness and usefulness were assessed using semistructured questionnaires. Nineteen GPs studied 94 patients. Passing-Bablok analysis showed a slope of 1.05 (95% CI 1.00 to 1.11) (R 2 =0.97). The percentage difference plot showed a mean difference of 15.7% (95% CI -46.0% to -77.4%). User-friendliness and usefulness had median scores of 4 or 5 on a five-point Likert scale. Eighteen out of 19 GPs confirmed that the device influenced their clinical practice. During the study, GPs' confidence in using NT-proBNP increased significantly from a mean score of 4.4 (95% CI 3.2 to 5.6) to 7.6 out of 10 (95% CI 7.1 to 8.2). The Cobas h232 NT-proBNP POC test proved to be an accurate, user-friendly and useful test in primary care. Nearly all participating GPs were convinced that the test could benefit clinical decision making. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. A research protocol for developing a Point-Of-Care Key Evidence Tool 'POCKET': a checklist for multidimensional evidence reporting on point-of-care in vitro diagnostics.

    PubMed

    Huddy, Jeremy R; Ni, Melody; Mavroveli, Stella; Barlow, James; Williams, Doris-Ann; Hanna, George B

    2015-07-10

    Point-of-care in vitro diagnostics (POC-IVD) are increasingly becoming widespread as an acceptable means of providing rapid diagnostic results to facilitate decision-making in many clinical pathways. Evidence in utility, usability and cost-effectiveness is currently provided in a fragmented and detached manner that is fraught with methodological challenges given the disruptive nature these tests have on the clinical pathway. The Point-of-care Key Evidence Tool (POCKET) checklist aims to provide an integrated evidence-based framework that incorporates all required evidence to guide the evaluation of POC-IVD to meet the needs of policy and decisionmakers in the National Health Service (NHS). A multimethod approach will be applied in order to develop the POCKET. A thorough literature review has formed the basis of a robust Delphi process and validation study. Semistructured interviews are being undertaken with POC-IVD stakeholders, including industry, regulators, commissioners, clinicians and patients to understand what evidence is required to facilitate decision-making. Emergent themes will be translated into a series of statements to form a survey questionnaire that aims to reach a consensus in each stakeholder group to what needs to be included in the tool. Results will be presented to a workshop to discuss the statements brought forward and the optimal format for the tool. Once assembled, the tool will be field-tested through case studies to ensure validity and usability and inform refinement, if required. The final version will be published online with a call for comments. Limitations include unpredictable sample representation, development of compromise position rather than consensus, and absence of blinding in validation exercise. The Imperial College Joint Research Compliance Office and the Imperial College Hospitals NHS Trust R&D department have approved the protocol. The checklist tool will be disseminated through a PhD thesis, a website, peer

  13. All-plastic, miniature, digital fluorescence microscope for three part white blood cell differential measurements at the point of care

    PubMed Central

    Forcucci, Alessandra; Pawlowski, Michal E.; Majors, Catherine; Richards-Kortum, Rebecca; Tkaczyk, Tomasz S.

    2015-01-01

    Three-part differential white blood cell counts are used for disease diagnosis and monitoring at the point-of-care. A low-cost, miniature achromatic microscope was fabricated for identification of lymphocytes, monocytes, and granulocytes in samples of whole blood stained with acridine orange. The microscope was manufactured using rapid prototyping techniques of diamond turning and 3D printing and is intended for use at the point-of-care in low-resource settings. The custom-designed microscope requires no manual adjustment between samples and was successfully able to classify three white blood cell types (lymphocytes, granulocytes, and monocytes) using samples of peripheral whole blood stained with acridine orange. PMID:26601006

  14. What Do Data Mean for Pre-Service Chemistry Teachers?

    ERIC Educational Resources Information Center

    Gültepe, Nejla

    2016-01-01

    This phenomologic study was carried out in order to determine how 63 pre-service chemistry teachers graduated from Chemistry Branch of Science Faculty in the pedagogical training program during 2013-2015 academic years defined the concepts of density and melting and boiling points and how they interpreted the data in micro levels. A diagnostic…

  15. Emerging Technologies for Monitoring Drug-Resistant Tuberculosis at the Point-of-Care

    PubMed Central

    Mani, Vigneshwaran; Wang, ShuQi; Inci, Fatih; De Libero, Gennaro; Singhal, Amit; Demirci, Utkan

    2014-01-01

    Infectious diseases are the leading cause of death worldwide. Among them, tuberculosis (TB) remains a major threat to public health, exacerbated by the emergence of multiple drug-resistant (MDR) and extensively drug-resistant (XDR) Mycobacterium tuberculosis (Mtb). MDR-Mtb strains are resistant to first-line anti-TB drugs such as isoniazid and rifampicin; whereas XDR-Mtb strains are resistant to additional drugs including at least to any fluoroquinolone and at least one of the second-line anti-TB injectable drugs such as kanamycin, capreomycin, or amikacin. Clinically, these strains have significantly impacted the management of TB in high-incidence developing countries, where systemic surveillance of TB drug resistance is lacking. For effective management of TB on-site, early detection of drug resistance is critical to initiate treatment, to reduce mortality, and to thwart drug-resistant TB transmission. In this review, we discuss the diagnostic challenges to detect drug-resistant TB at the point-of-care (POC). Moreover, we present the latest advances in nano/microscale technologies that can potentially detect TB drug resistance to improve on-site patient care. PMID:24882226

  16. The semantics of Chemical Markup Language (CML) for computational chemistry : CompChem.

    PubMed

    Phadungsukanan, Weerapong; Kraft, Markus; Townsend, Joe A; Murray-Rust, Peter

    2012-08-07

    : This paper introduces a subdomain chemistry format for storing computational chemistry data called CompChem. It has been developed based on the design, concepts and methodologies of Chemical Markup Language (CML) by adding computational chemistry semantics on top of the CML Schema. The format allows a wide range of ab initio quantum chemistry calculations of individual molecules to be stored. These calculations include, for example, single point energy calculation, molecular geometry optimization, and vibrational frequency analysis. The paper also describes the supporting infrastructure, such as processing software, dictionaries, validation tools and database repositories. In addition, some of the challenges and difficulties in developing common computational chemistry dictionaries are discussed. The uses of CompChem are illustrated by two practical applications.

  17. The semantics of Chemical Markup Language (CML) for computational chemistry : CompChem

    PubMed Central

    2012-01-01

    This paper introduces a subdomain chemistry format for storing computational chemistry data called CompChem. It has been developed based on the design, concepts and methodologies of Chemical Markup Language (CML) by adding computational chemistry semantics on top of the CML Schema. The format allows a wide range of ab initio quantum chemistry calculations of individual molecules to be stored. These calculations include, for example, single point energy calculation, molecular geometry optimization, and vibrational frequency analysis. The paper also describes the supporting infrastructure, such as processing software, dictionaries, validation tools and database repositories. In addition, some of the challenges and difficulties in developing common computational chemistry dictionaries are discussed. The uses of CompChem are illustrated by two practical applications. PMID:22870956

  18. Point-of-care C-reactive protein testing to reduce inappropriate use of antibiotics for non-severe acute respiratory infections in Vietnamese primary health care: a randomised controlled trial.

    PubMed

    Do, Nga T T; Ta, Ngan T D; Tran, Ninh T H; Than, Hung M; Vu, Bich T N; Hoang, Long B; van Doorn, H Rogier; Vu, Dung T V; Cals, Jochen W L; Chandna, Arjun; Lubell, Yoel; Nadjm, Behzad; Thwaites, Guy; Wolbers, Marcel; Nguyen, Kinh V; Wertheim, Heiman F L

    2016-09-01

    Inappropriate antibiotic use for acute respiratory tract infections is common in primary health care, but distinguishing serious from self-limiting infections is difficult, particularly in low-resource settings. We assessed whether C-reactive protein point-of-care testing can safely reduce antibiotic use in patients with non-severe acute respiratory tract infections in Vietnam. We did a multicentre open-label randomised controlled trial in ten primary health-care centres in northern Vietnam. Patients aged 1-65 years with at least one focal and one systemic symptom of acute respiratory tract infection were assigned 1:1 to receive either C-reactive protein point-of-care testing or routine care, following which antibiotic prescribing decisions were made. Patients with severe acute respiratory tract infection were excluded. Enrolled patients were reassessed on day 3, 4, or 5, and on day 14 a structured telephone interview was done blind to the intervention. Randomised assignments were concealed from prescribers and patients but not masked as the test result was used to assist treatment decisions. The primary outcome was antibiotic use within 14 days of follow-up. All analyses were prespecified in the protocol and the statistical analysis plan. All analyses were done on the intention-to-treat population and the analysis of the primary endpoint was repeated in the per-protocol population. This trial is registered under number NCT01918579. Between March 17, 2014, and July 3, 2015, 2037 patients (1028 children and 1009 adults) were enrolled and randomised. One adult patient withdrew immediately after randomisation. 1017 patients were assigned to receive C-reactive protein point-of-care testing, and 1019 patients were assigned to receive routine care. 115 patients in the C-reactive protein point-of-care group and 72 patients in the routine care group were excluded in the intention-to-treat analysis due to missing primary endpoint. The number of patients who used antibiotics

  19. High-Value Consults: A Curriculum to Promote Point-of-Care, Evidence-Based Recommendations.

    PubMed

    Nandiwada, Deepa Rani; Kohli, Amar; McNamara, Megan; Smith, Kenneth J; Zimmer, Shanta; McNeil, Melissa; Spagnoletti, Carla; Rubio, Doris; Berlacher, Kathryn

    2017-10-01

    In an era when value-based care is paramount, teaching trainees to explicitly communicate the evidence behind recommendations fosters high-value care (HVC) in the consultation process. To implement an HVC consult curriculum highlighting the need for clear consult questions, evidence-based recommendations to improve consult teaching, clinical decision-making, and the educational value of consults. A pilot curriculum was implemented for residents on cardiology consult electives utilizing faculty and fellows as evidence-based medicine (EBM) coaches. The curriculum included an online module, an EBM teaching point template, EBM presentations on rounds, and "coach" feedback on notes. A total of 15 residents and 4 fellows on cardiology consults participated, and 87% (13 of 15) of residents on consults felt the curriculum was educationally valuable. A total of 80% (72 of 90) of residents on general medicine rotations responded to the survey, and 25 of 72 residents (35%) had a consult with the EBM template. General medicine teams felt the EBM teaching points affected clinical decision-making (48%, 12 of 25) and favored dissemination of the curriculum (90%, 72 of 80). Checklist-guided chart review showed a 22% improvement in evidence-based summaries behind recommendations (7 of 36 precurriculum to 70 of 146 charts postcurriculum, P  = .015). The HVC consult curriculum during a cardiology elective was perceived by residents to influence clinical decision-making and evidence-based recommendations, and was found to be educationally valuable on both parties in the consult process.

  20. Cardiovascular point of care initiative: enhancements in clinical data management.

    PubMed

    Robertson, Jane

    2003-01-01

    The Department of Cardiovascular Surgery at East Alabama Medical Center (EAMC) initiated a program in 1996 to improve the quality and usefulness of clinical outcomes data. After years of using a commercial vendor product and enduring a tedious collection process, the department decided to develop its own tools to support quality improvement efforts. Using a hand-held personal data assistant (PDA), the team developed tools that allowed ongoing data collection at the point of care delivery. The tools and methods facilitated the collection of real time, accurate information that allowed EAMC to participate in multiple clinical quality initiatives. The ability to conduct rapid-cycle performance improvement studies propelled EAMC's Cardiovascular Surgery Program into the Top 100 as recognized by HCIA, now Solucient, for 3 consecutive years (1999-2001). This report will describe the evolution of the data collection process as well as the quality improvements that resulted.

  1. Single-Molecule Reaction Chemistry in Patterned Nanowells

    PubMed Central

    2016-01-01

    A new approach to synthetic chemistry is performed in ultraminiaturized, nanofabricated reaction chambers. Using lithographically defined nanowells, we achieve single-point covalent chemistry on hundreds of individual carbon nanotube transistors, providing robust statistics and unprecedented spatial resolution in adduct position. Each device acts as a sensor to detect, in real-time and through quantized changes in conductance, single-point functionalization of the nanotube as well as consecutive chemical reactions, molecular interactions, and molecular conformational changes occurring on the resulting single-molecule probe. In particular, we use a set of sequential bioconjugation reactions to tether a single-strand of DNA to the device and record its repeated, reversible folding into a G-quadruplex structure. The stable covalent tether allows us to measure the same molecule in different solutions, revealing the characteristic increased stability of the G-quadruplex structure in the presence of potassium ions (K+) versus sodium ions (Na+). Nanowell-confined reaction chemistry on carbon nanotube devices offers a versatile method to isolate and monitor individual molecules during successive chemical reactions over an extended period of time. PMID:27270004

  2. Myoglobin chemistry and meat color.

    PubMed

    Suman, Surendranath P; Joseph, Poulson

    2013-01-01

    Consumers rely heavily on fresh meat color as an indicator of wholesomeness at the point of sale, whereas cooked color is exploited as an indicator of doneness at the point of consumption. Deviations from the bright cherry-red color of fresh meat lead to product rejection and revenue loss. Myoglobin is the sarcoplasmic heme protein primarily responsible for the meat color, and the chemistry of myoglobin is species specific. The mechanistic interactions between myoglobin and multiple extrinsic and intrinsic factors govern the color of raw as well as cooked meats. The objective of this review is to provide an overview of the current research in meat color and how the findings are applied in the meat industry. Characterizing the fundamental basis of myoglobin's interactions with biomolecules in postmortem skeletal muscles is necessary to interpret the chemistry of meat color phenomena and to engineer innovative processing strategies to minimize meat discoloration-induced revenue loss to the agricultural economy.

  3. Analytical Chemistry and the Microchip.

    ERIC Educational Resources Information Center

    Lowry, Robert K.

    1986-01-01

    Analytical techniques used at various points in making microchips are described. They include: Fourier transform infrared spectrometry (silicon purity); optical emission spectroscopy (quantitative thin-film composition); X-ray photoelectron spectroscopy (chemical changes in thin films); wet chemistry, instrumental analysis (process chemicals);…

  4. Seroprevalence of equine granulocytic anaplasmosis and lyme borreliosis in Canada as determined by a point-of-care enzyme-linked immunosorbent assay (ELISA).

    PubMed

    Schvartz, Gili; Epp, Tasha; Burgess, Hilary J; Chilton, Neil B; Pearl, David L; Lohmann, Katharina L

    2015-06-01

    Equine granulocytic anaplasmosis (EGA) and Lyme borreliosis (LB) are an emerging concern in Canada. We estimated the seroprevalence of EGA and equine LB by testing 376 convenience serum samples from 3 provinces using a point-of-care SNAP(®) 4Dx(®) ELISA (IDEXX Laboratories, Westbrook, Maine, USA), and investigated the agreement between the point-of-care ELISA and laboratory-based serologic tests. The estimated seroprevalence for EGA was 0.53% overall (0.49% in Saskatchewan, 0.71% in Manitoba), while the estimated seroprevalence for LB was 1.6% overall (0.49% in Saskatchewan, 2.86% in Manitoba). There was limited agreement between the point-of-care ELISA and an indirect fluorescent antibody test for EGA (kappa 0.1, PABAK 0.47) and an ELISA/Western blot combination for LB (kappa 0.23, PABAK 0.71). While the SNAP(®) 4Dx(®) ELISA yielded expected seroprevalence estimates, further evaluation of serologic tests for the purposes of disease exposure recognition may be needed.

  5. Multivalent Nanoparticle Networks Enable Point of Care Detection of Human Phospholipase-A2 in Serum

    PubMed Central

    Burnapp, Mark; Bentham, Andrew; Hillier, David; Zabron, Abigail; Khan, Shahid; Tyreman, Matthew; Stevens, Molly M.

    2017-01-01

    A rapid and highly sensitive point of care (PoC) lateral flow assay for phospholipase-A2 (PLA2) is demonstrated in serum through the enzyme-triggered release of a new class of biotinylated multi-armed polymers from a liposome substrate. Signal from the enzyme activity is generated by the adhesion of polystreptavidin coated gold nanoparticle networks to the lateral flow device, which leads to the appearance of a red test line due to the localised surface plasmon resonance (LSPR) effect of the gold. The use of a liposome as the enzyme substrate and multivalent linkers to link the nanoparticles leads to amplification of the signal as the cleavage of a small amount of lipids is able to release a large amount of polymer linker and adhesion of an even larger amount of gold nanoparticles. By optimising the molecular weight and multivalency of these biotinylated polymer linkers the sensitivity of the device can be tuned to enable naked-eye detection of 1 nM human-PLA2 in serum within 10 minutes. This high sensitivity enabled the correct diagnosis of pancreatitis in diseased clinical samples against a set of healthy controls using PLA2 activity in a point of care device for the first time. PMID:25756526

  6. Prospective evaluation of three point of care devices for glycemia measurement in a neonatal intensive care unit.

    PubMed

    Diaw, Corinne Stadelmann; Piol, Nicolas; Urfer, Jocelyne; Werner, Dominique; Roth-Kleiner, Matthias

    2013-10-21

    Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology. © 2013.

  7. Where are we at with point-of-care testing in haematology?

    PubMed

    Briggs, Carol; Kimber, Simon; Green, Laura

    2012-09-01

    Point-of-care testing (POCT) in haematology has continued to grow in popularity and uptake throughout the world. The increasing demand to reduce the turnaround time of test results, coupled with rapid improvements in technology, have led to the development of several devices that are designed for use in different clinical settings, with the hope of improving patient care. The most used POCT in haematology is measurement of haemoglobin concentration. Other POCT devices (used primarily in developing countries) for malaria screening and CD4+ T-lymphocytes for quantification of human-immunodeficiency-virus are becoming the cornerstone for the diagnosis and management of these disorders. New devices are also available for red cell indices, white blood cell count and platelets. In this review clinical studies that validate the use of such devices will be discussed, as well as the advantages and disadvantages of POCT in haematology. A disadvantage of POCT is a lack of training, poor standardization in obtaining blood samples and insufficient internal/external quality assessment. As there is every reason to expect that POCT use will increase in all pathology disciplines, including haematology, it is imperative that systems are put in place to oversee these issues. © 2012 Blackwell Publishing Ltd.

  8. Cost-effectiveness analysis of early point-of-care lactate testing in the emergency department.

    PubMed

    Ward, Michael J; Self, Wesley H; Singer, Adam; Lazar, Danielle; Pines, Jesse M

    2016-12-01

    To determine the cost-effectiveness of implementing a point-of-care (POC) Lactate Program in the emergency department (ED) for patients with suspected sepsis to identify patients who can benefit from early resuscitation. We constructed a cost-effectiveness model to examine an ED with 30 000 patients annually. We evaluated a POC lactate program screening patients with suspected sepsis for an elevated lactate ≥4 mmol/L. Those with elevated lactate levels are resuscitated and their lactate clearance is evaluated by serial POC lactate measurements. The POC Lactate Program was compared with a Usual Care Strategy in which all patients with sepsis and an elevated lactate are admitted to the intensive care unit. Costs were estimated from the 2014 Medicare Inpatient and National Physician Fee schedules, and hospital and industry estimates. In the base-case, the POC Lactate Program cost $39.53/patient whereas the Usual Care Strategy cost $33.20/patient. The screened patients in the POC arm resulted in 1.07 quality-adjusted life years for an incremental cost-effectiveness ratio of $31 590 per quality-adjusted life year gained, well below accepted willingness-to-pay-thresholds. Implementing a POC Lactate Program for screening ED patients with suspected sepsis is a cost-effective intervention to identify patients responsive to early resuscitation. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Point-of-care ultrasound diagnosis and treatment of posterior shoulder dislocation.

    PubMed

    Beck, Sierra; Chilstrom, Mikaela

    2013-02-01

    Acute traumatic posterior shoulder dislocations are rare. The diagnosis is often missed or delayed, as radiologic abnormalities can be subtle. We report a case of a 37-year-old man who presented to the emergency department with severe right shoulder pain and inability to move his arm after a motor vehicle collision. Based on examination, he was initially thought to have an anterior dislocation; however, point-of-care (POC) ultrasound clearly demonstrated a posterior shoulder dislocation. Real-time ultrasound-guided intra-articular local anesthetic injection facilitated closed reduction in the emergency department without procedural sedation, and POC ultrasound confirmed successful reduction at the bedside after the procedure. This case demonstrates that POC ultrasound can be a useful diagnostic tool in the rapid assessment and treatment for patients with suspected posterior shoulder dislocation. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Optimal Management of the Critically Ill: Anaesthesia, Monitoring, Data Capture, and Point-of-Care Technological Practices in Ovine Models of Critical Care

    PubMed Central

    Shekar, Kiran; Tung, John-Paul; Dunster, Kimble R.; Platts, David; Watts, Ryan P.; Gregory, Shaun D.; Simonova, Gabriela; McDonald, Charles; Hayes, Rylan; Bellpart, Judith; Timms, Daniel; Fung, Yoke L.; Toon, Michael; Maybauer, Marc O.; Fraser, John F.

    2014-01-01

    Animal models of critical illness are vital in biomedical research. They provide possibilities for the investigation of pathophysiological processes that may not otherwise be possible in humans. In order to be clinically applicable, the model should simulate the critical care situation realistically, including anaesthesia, monitoring, sampling, utilising appropriate personnel skill mix, and therapeutic interventions. There are limited data documenting the constitution of ideal technologically advanced large animal critical care practices and all the processes of the animal model. In this paper, we describe the procedure of animal preparation, anaesthesia induction and maintenance, physiologic monitoring, data capture, point-of-care technology, and animal aftercare that has been successfully used to study several novel ovine models of critical illness. The relevant investigations are on respiratory failure due to smoke inhalation, transfusion related acute lung injury, endotoxin-induced proteogenomic alterations, haemorrhagic shock, septic shock, brain death, cerebral microcirculation, and artificial heart studies. We have demonstrated the functionality of monitoring practices during anaesthesia required to provide a platform for undertaking systematic investigations in complex ovine models of critical illness. PMID:24783206

  11. Linear and volumetric dimensional changes of injection-molded PMMA denture base resins.

    PubMed

    El Bahra, Shadi; Ludwig, Klaus; Samran, Abdulaziz; Freitag-Wolf, Sandra; Kern, Matthias

    2013-11-01

    The aim of this study was to evaluate the linear and volumetric dimensional changes of six denture base resins processed by their corresponding injection-molding systems at 3 time intervals of water storage. Two heat-curing (SR Ivocap Hi Impact and Lucitone 199) and four auto-curing (IvoBase Hybrid, IvoBase Hi Impact, PalaXpress, and Futura Gen) acrylic resins were used with their specific injection-molding technique to fabricate 6 specimens of each material. Linear and volumetric dimensional changes were determined by means of a digital caliper and an electronic hydrostatic balance, respectively, after water storage of 1, 30, or 90 days. Means and standard deviations of linear and volumetric dimensional changes were calculated in percentage (%). Statistical analysis was done using Student's and Welch's t tests with Bonferroni-Holm correction for multiple comparisons (α=0.05). Statistically significant differences in linear dimensional changes between resins were demonstrated at all three time intervals of water immersion (p≤0.05), with exception of the following comparisons which showed no significant difference: IvoBase Hi Impact/SR Ivocap Hi Impact and PalaXpress/Lucitone 199 after 1 day, Futura Gen/PalaXpress and PalaXpress/Lucitone 199 after 30 days, and IvoBase Hybrid/IvoBase Hi Impact after 90 days. Also, statistically significant differences in volumetric dimensional changes between resins were found at all three time intervals of water immersion (p≤0.05), with exception of the comparison between PalaXpress and Futura Gen. Denture base resins (IvoBase Hybrid and IvoBase Hi Impact) processed by the new injection-molding system (IvoBase), revealed superior dimensional precision. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Criteria required for an acceptable point-of-care test for UTI detection: Obtaining consensus using the Delphi technique

    PubMed Central

    Kearney, Paddy; Stafford, Bob; Gormley, Gerard J.; Crockard, Martin A.; Gilpin, Deirdre F.

    2018-01-01

    Background Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Methods Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. Results The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. Conclusion This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test. PMID:29879161

  13. Maximizing the Adjacent Possible in Automata Chemistries.

    PubMed

    Hickinbotham, Simon; Clark, Edward; Nellis, Adam; Stepney, Susan; Clarke, Tim; Young, Peter

    2016-01-01

    Automata chemistries are good vehicles for experimentation in open-ended evolution, but they are by necessity complex systems whose low-level properties require careful design. To aid the process of designing automata chemistries, we develop an abstract model that classifies the features of a chemistry from a physical (bottom up) perspective and from a biological (top down) perspective. There are two levels: things that can evolve, and things that cannot. We equate the evolving level with biology and the non-evolving level with physics. We design our initial organisms in the biology, so they can evolve. We design the physics to facilitate evolvable biologies. This architecture leads to a set of design principles that should be observed when creating an instantiation of the architecture. These principles are Everything Evolves, Everything's Soft, and Everything Dies. To evaluate these ideas, we present experiments in the recently developed Stringmol automata chemistry. We examine the properties of Stringmol with respect to the principles, and so demonstrate the usefulness of the principles in designing automata chemistries.

  14. Value of point-of-care ketones in assessing dehydration and acidosis in children with gastroenteritis.

    PubMed

    Levy, Jason A; Waltzman, Mark; Monuteaux, Michael C; Bachur, Richard G

    2013-11-01

    Children with gastroenteritis often develop dehydration with metabolic acidosis. Serum ketones are frequently elevated in this population. The goal was to determine the relationship between initial serum ketone concentration and both the degree of dehydration and the magnitude of acidosis. This was a secondary analysis of a prospective trial of crystalloid administration for rapid rehydration. Children 6 months to 6 years of age with gastroenteritis and dehydration were enrolled. A point-of-care serum ketone (beta-hydroxybutyrate) concentration was obtained at the time of study enrollment. The relationship between initial serum ketone concentration and a prospectively assigned and previously validated clinical dehydration score, and serum bicarbonate concentration, was analyzed. A total of 188 patients were enrolled. The median serum ketone concentration was elevated at 3.1 mmol/L (interquartile range [IQR] = 1.2 to 4.6 mmol/L), and the median dehydration score was consistent with moderate dehydration. A significant positive relationship was found between serum ketone concentration and the clinical dehydration score (Spearman's rho = 0.22, p = 0.003). Patients with moderate dehydration had a higher median serum ketone concentration than those with mild dehydration (3.6 mmol/L vs. 1.4 mmol/L, p = 0.007). Additionally, the serum ketone concentration was inversely correlated with serum bicarbonate concentration (ρ = -0.26, p < 0.001). Children with gastroenteritis and dehydration have elevated serum ketone concentrations that correlate with both degree of dehydration and magnitude of metabolic acidosis. Point-of-care serum ketone measurement may be a useful tool to inform management decisions at the point of triage or in the initial evaluation of children with gastroenteritis and dehydration. © 2013 by the Society for Academic Emergency Medicine.

  15. Point-of-care diagnostics: extending the laboratory network to reach the last mile.

    PubMed

    Drain, Paul K; Rousseau, Christine

    2017-03-01

    More point-of-care (POC) diagnostic tests are becoming available for HIV diagnosis and treatment in resource-limited settings. These novel technologies have the potential to foster decentralized HIV care and treatment for the benefit of clinical laboratories, HIV clinics, and HIV-infected patients. There continue to be many business, technological, and operational challenges that limit product development and regulatory approval, which limits products available for the required operational and cost-effectiveness studies and delays policy adoption and implementation. Although the rapid HIV diagnostic test has been widely successful, the pathways for POC CD4 cell count and HIV viral load assay analyzers have been more challenging. We describe significant hurdles for product development, approval, and implementation, which include the business case, technical development, clinical impact, and integrating laboratory and clinical networks. The objective of this review is to highlight the obstacles for developing and implementing appropriate strategies for POC HIV testing assays to improve the clinical services for HIV-infected patients in resource-limited settings.

  16. Love Story: Oxygen in Organic Chemistry

    ERIC Educational Resources Information Center

    Roberts, John D.

    1974-01-01

    Significant discoveries and developments regarding oxygen and organic compounds are recounted to show that research in this specific area is worthwhile and relevant and to point out that research in other areas of organic chemistry deserves continued encouragement as well. (DT)

  17. Turbine Chemistry Modeling

    NASA Technical Reports Server (NTRS)

    Liu, Nan-Suey; Wey, Thomas

    2001-01-01

    Many of the engine exhaust species resulting in significant environmental impact exist in trace amounts. Recent research, e.g., conducted at MIT-AM, has pointed to the intra-engine environment as a possible site for important trace chemistry activity. In addition, the key processes affecting the trace species activity occurring downstream in the air passages of the turbine and exhaust nozzle are not well understood. Most recently, an effort has been initiated at NASA Glenn Research Center under the UEET Program to evaluate and further develop CFD-based technology for modeling and simulation of intra-engine trace chemical changes relevant to atmospheric effects of pollutant emissions from aircraft engines. This presentation will describe the current effort conducted at Glenn; some preliminary results relevant to the trace species chemistry in a turbine passage will also be presented to indicate the progress to date.

  18. A System-on-Chip Solution for Point-of-Care Ultrasound Imaging Systems: Architecture and ASIC Implementation.

    PubMed

    Kang, Jeeun; Yoon, Changhan; Lee, Jaejin; Kye, Sang-Bum; Lee, Yongbae; Chang, Jin Ho; Kim, Gi-Duck; Yoo, Yangmo; Song, Tai-kyong

    2016-04-01

    In this paper, we present a novel system-on-chip (SOC) solution for a portable ultrasound imaging system (PUS) for point-of-care applications. The PUS-SOC includes all of the signal processing modules (i.e., the transmit and dynamic receive beamformer modules, mid- and back-end processors, and color Doppler processors) as well as an efficient architecture for hardware-based imaging methods (e.g., dynamic delay calculation, multi-beamforming, and coded excitation and compression). The PUS-SOC was fabricated using a UMC 130-nm NAND process and has 16.8 GFLOPS of computing power with a total equivalent gate count of 12.1 million, which is comparable to a Pentium-4 CPU. The size and power consumption of the PUS-SOC are 27×27 mm(2) and 1.2 W, respectively. Based on the PUS-SOC, a prototype hand-held US imaging system was implemented. Phantom experiments demonstrated that the PUS-SOC can provide appropriate image quality for point-of-care applications with a compact PDA size ( 200×120×45 mm(3)) and 3 hours of battery life.

  19. Caring for the Environment While Teaching Organic Chemistry

    NASA Astrophysics Data System (ADS)

    Santos Santos, Elvira; Cruz Gavilan Garcia, Irma; Florencia Lejarazo Gomez, Eva

    2004-02-01

    In laboratory experiments it is common for students to acquire knowledge and develop the basic abilities needed to solve different types of problems related to synthesis and analysis. The students are so interested in this objective that they do not generally pay any attention to the wastes generated during their lab experiments. It is well known that experiments usually generate small quantities of a large variety of wastes. Nevertheless, the complexity of the wastes generated in the laboratories of educational institutions is large. Thus, detailed studies of their treatment should be undertaken. In North American and European universities the problem has been solved by sending these wastes to specialized companies that treat and dispose of them; however, in Mexico, such alternatives are not available owing to the high cost for waste disposal. Therefore, the Organic Chemistry Department of the Chemistry School at the National Autonomous University of Mexico has started a project concerned with the management and treatment of wastes generated during experimental lab sessions. In the United States and Europe, students do not generally treat their wastes. Therefore, it would be convenient to include this treatment as part of the educational aspects in organic experiments in all parts of the world to develop an environmentally conscience culture among them.

  20. A paper based graphene-nanocauliflower hybrid composite for point of care biosensing

    NASA Astrophysics Data System (ADS)

    Burrs, S. L.; Sidhu, R.; Bhargava, M.; Kiernan-Lewis, J.; Schwalb, N.; Rong, Y.; Gomes, C.; Claussen, J.; Vanegas, D. C.; McLamore, E. S.

    2016-05-01

    Graphene paper has diverse applications in printed circuit board electronics, bioassays, 3D cell culture, and biosensing. Although development of nanometal-graphene hybrid composites is commonplace in the sensing literature, to date there are only a few examples of nanometal-decorated graphene paper for use in biosensing. In this manuscript, we demonstrate the synthesis and application of Pt nano cauliflower-functionalized graphene paper for use in electrochemical biosensing of small molecules (glucose, acetone, methanol) or detection of pathogenic bacteria (Escherichia coli O157:H7). Raman spectroscopy, scanning electron microscopy and energy dispersive spectroscopy were used to show that graphene oxide deposited on nanocellulose crystals was partially reduced by both thermal and chemical treatment. Fractal platinum nanostructures were formed on the reduced graphene oxide paper, producing a conductive paper with an extremely high electroactive surface area, confirmed by cyclic voltammetry and electrochemical impedance spectroscopy. To show the broad applicability of the material, the platinum surface was functionalized with three different biomaterials: 1) glucose oxidase (via chitosan encapsulation); 2) a DNA aptamer (via covalent linking), or 3) a chemosensory protein (via his linking). We demonstrate the application of this device for point of care biosensing. The detection limit for both glucose (0.08 +/- 0.02 μM) and E. coli O157:H7 (1.3 +/- 0.1 CFU mL-1) were competitive with, or superior to, previously reported devices in the biosensing literature. The response time (6 sec for glucose and 10 min for E. coli) were also similar to silicon biochip and commercial electrode sensors. The results demonstrate that the nanocellulose-graphene-nanoplatinum material is an excellent paper-based platform for development of electrochemical biosensors targeting small molecules or whole cells for use in point of care biosensing.

  1. Implementation of a 4-Year Point-of-Care Ultrasound Curriculum in a Liaison Committee on Medical Education-Accredited US Medical School.

    PubMed

    Wilson, Sean P; Mefford, Jason M; Lahham, Shadi; Lotfipour, Shahram; Subeh, Mohammad; Maldonado, Gracie; Spann, Sophie; Fox, John C

    2017-02-01

    The established benefits of point-of-care ultrasound have given rise to multiple new and innovative curriculums to incorporate ultrasound teaching into medical education. This study sought to measure the educational success of a comprehensive and integrated 4-year point-of-care ultrasound curriculum. We integrated a curriculum consisting of traditional didactics combined with asynchronous learning modules and hands-on practice on live models with skilled sonographers into all 4 years of education at a Liaison Committee on Medical Education-accredited US Medical School. Each graduating student was administered an exit examination with 48 questions that corresponded to ultrasound milestones. Ninety-five percent (n = 84) of fourth-year medical students completed the exit examination. The mean score was 79.5% (SD, 10.2%), with mean scores on the ultrasound physics and anatomy subsections being 77.1% (SD, 11.0%) and 85.9% (SD, 21.0%), respectively. A comprehensive 4-year point-of-care ultrasound curriculum integrated into medical school may successfully equip graduating medical students with a fundamental understanding of ultrasound physics, anatomy, and disease recognition. © 2016 by the American Institute of Ultrasound in Medicine.

  2. Should all acutely ill children in primary care be tested with point-of-care CRP: a cluster randomised trial.

    PubMed

    Verbakel, Jan Y; Lemiengre, Marieke B; De Burghgraeve, Tine; De Sutter, An; Aertgeerts, Bert; Shinkins, Bethany; Perera, Rafael; Mant, David; Van den Bruel, Ann; Buntinx, Frank

    2016-10-06

    Point-of-care blood C-reactive protein (CRP) testing has diagnostic value in helping clinicians rule out the possibility of serious infection. We investigated whether it should be offered to all acutely ill children in primary care or restricted to those identified as at risk on clinical assessment. Cluster randomised controlled trial involving acutely ill children presenting to 133 general practitioners (GPs) at 78 GP practices in Belgium. Practices were randomised to undertake point-of-care CRP testing in all children (1730 episodes) or restricted to children identified as at clinical risk (1417 episodes). Clinical risk was assessed by a validated clinical decision rule (presence of one of breathlessness, temperature ≥ 40 °C, diarrhoea and age 12-30 months, or clinician concern). The main trial outcome was hospital admission with serious infection within 5 days. No specific guidance was given to GPs on interpreting CRP levels but diagnostic performance is reported at 5, 20, 80 and 200 mg/L. Restricting CRP testing to those identified as at clinical risk substantially reduced the number of children tested by 79.9 % (95 % CI, 77.8-82.0 %). There was no significant difference between arms in the number of children with serious infection who were referred to hospital immediately (0.16 % vs. 0.14 %, P = 0.88). Only one child with a CRP < 5 mg/L had an illness requiring admission (a child with viral gastroenteritis admitted for rehydration). However, of the 80 children referred to hospital to rule out serious infection, 24 (30.7 %, 95 % CI, 19.6-45.6 %) had a CRP < 5 mg/L. CRP testing should be restricted to children at higher risk after clinical assessment. A CRP < 5 mg/L rules out serious infection and could be used by GPs to avoid unnecessary hospital referrals. ClinicalTrials.gov Identifier: NCT02024282 (registered on 14 th September 2012).

  3. A Demonstration of the Continuous Phase (Second-Order) Transition of a Binary Liquid System in the Region around Its Critical Point

    ERIC Educational Resources Information Center

    Johnson, Michael R.

    2006-01-01

    In most general chemistry and introductory physical chemistry classes, critical point is defined as that temperature-pressure point on a phase diagram where the liquid-gas interface disappears, a phenomenon that generally occurs at relatively high temperatures or high pressures. Two examples are: water, with a critical point at 647 K (critical…

  4. Microfluidic-integrated biosensors: prospects for point-of-care diagnostics.

    PubMed

    Kumar, Suveen; Kumar, Saurabh; Ali, Md Azahar; Anand, Pinki; Agrawal, Ved Varun; John, Renu; Maji, Sagar; Malhotra, Bansi D

    2013-11-01

    There is a growing demand to integrate biosensors with microfluidics to provide miniaturized platforms with many favorable properties, such as reduced sample volume, decreased processing time, low cost analysis and low reagent consumption. These microfluidics-integrated biosensors would also have numerous advantages such as laminar flow, minimal handling of hazardous materials, multiple sample detection in parallel, portability and versatility in design. Microfluidics involves the science and technology of manipulation of fluids at the micro- to nano-liter level. It is predicted that combining biosensors with microfluidic chips will yield enhanced analytical capability, and widen the possibilities for applications in clinical diagnostics. The recent developments in microfluidics have helped researchers working in industries and educational institutes to adopt some of these platforms for point-of-care (POC) diagnostics. This review focuses on the latest advancements in the fields of microfluidic biosensing technologies, and on the challenges and possible solutions for translation of this technology for POC diagnostic applications. We also discuss the fabrication techniques required for developing microfluidic-integrated biosensors, recently reported biomarkers, and the prospects of POC diagnostics in the medical industry. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Scenario-Based Assessment of User Needs for Point-of-Care Robots.

    PubMed

    Lee, Hyeong Suk; Kim, Jeongeun

    2018-01-01

    This study aimed to derive specific user requirements and barriers in a real medical environment to define the essential elements and functions of two types of point-of-care (POC) robot: a telepresence robot as a tool for teleconsultation, and a bedside robot to provide emotional care for patients. An analysis of user requirements was conducted; user needs were gathered and identified, and detailed, realistic scenarios were created. The prototype robots were demonstrated in physical environments for envisioning and evaluation. In all, three nurses and three clinicians participated as evaluators to observe the demonstrations and evaluate the robot systems. The evaluators were given a brief explanation of each scene and the robots' functionality. Four major functions of the teleconsultation robot were defined and tested in the demonstration. In addition, four major functions of the bedside robot were evaluated. Among the desired functions for a teleconsultation robot, medical information delivery and communication had high priority. For a bedside robot, patient support, patient monitoring, and healthcare provider support were the desired functions. The evaluators reported that the teleconsultation robot can increase support from and access to specialists and resources. They mentioned that the bedside robot can improve the quality of hospital life. Problems identified in the demonstration were those of space conflict, communication errors, and safety issues. Incorporating this technology into healthcare services will enhance communication and teamwork skills across distances and thereby facilitate teamwork. However, repeated tests will be needed to evaluate and ensure improved performance.

  6. Microfluidic Surface Plasmon Resonance Sensors: From Principles to Point-of-Care Applications

    PubMed Central

    Wang, Da-Shin; Fan, Shih-Kang

    2016-01-01

    Surface plasmon resonance (SPR) is a label-free, highly-sensitive, and real-time sensing technique. Conventional SPR sensors, which involve a planar thin gold film, have been widely exploited in biosensing; various miniaturized formats have been devised for portability purposes. Another type of SPR sensor which utilizes localized SPR (LSPR), is based on metal nanostructures with surface plasmon modes at the structural interface. The resonance condition is sensitive to the refractive index change of the local medium. The principles of these two types of SPR sensors are reviewed and their integration with microfluidic platforms is described. Further applications of microfluidic SPR sensors to point-of-care (POC) diagnostics are discussed. PMID:27472340

  7. Emerging technologies for monitoring drug-resistant tuberculosis at the point-of-care.

    PubMed

    Mani, Vigneshwaran; Wang, ShuQi; Inci, Fatih; De Libero, Gennaro; Singhal, Amit; Demirci, Utkan

    2014-11-30

    Infectious diseases are the leading cause of death worldwide. Among them, tuberculosis (TB) remains a major threat to public health, exacerbated by the emergence of multiple drug-resistant (MDR) and extensively drug-resistant (XDR) Mycobacterium tuberculosis (Mtb). MDR-Mtb strains are resistant to first-line anti-TB drugs such as isoniazid and rifampicin; whereas XDR-Mtb strains are resistant to additional drugs including at least to any fluoroquinolone and one of the second-line anti-TB injectable drugs such as kanamycin, capreomycin, or amikacin. Clinically, these strains have significantly impacted the management of TB in high-incidence developing countries, where systemic surveillance of TB drug resistance is lacking. For effective management of TB on-site, early detection of drug resistance is critical to initiate treatment, to reduce mortality, and to thwart drug-resistant TB transmission. In this review, we discuss the diagnostic challenges to detect drug-resistant TB at the point-of-care (POC). Moreover, we present the latest advances in nano/microscale technologies that can potentially detect TB drug resistance to improve on-site patient care. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Evolution of groundwater chemistry along fault structures in sandstone

    NASA Astrophysics Data System (ADS)

    Dausse, A.; Guiheneuf, N.; Pierce, A. A.; Cherry, J. A.; Parker, B. L.

    2016-12-01

    Fluid-rock interaction across geological structures plays a major role on evolution of groundwater chemistry and physical properties of reservoirs. In particular, groundwater chemistry evolve on different facies according to residence times which can be linked to hydraulic properties of the geological unit. In this study, we analyze groundwater samples collected at an 11 km² site located in southern California (USA) to evaluate the evolution of groundwater chemistry according to different geological structures. Major and minor elements were sampled at the same period of time from 40 wells located along the main structures in the northeast of the site, where major NE-SW trending faults and other oriented ESE-WNW are present in sandstone Chatsworth formation. By analyzing the spatial distribution of ions concentration at the site scale, several hydrochemical compartments (main- and sub-compartments) can be distinguished and are in agreement with structural and hydrological information. In particular, as previously observed from piezometric informations, the shear zone fault serves as a barrier for groundwater flow and separates the site on two mains compartments. In addition, the analysis along major faults oriented orthogonal to this shear zone (ESE-WNW) in the eastern part of the site, shows an increase in mineralization following the hydraulic gradient. This salinization has been confirmed by ionic ratio and Gibbs plots and is attributed to fluid-rock interaction processes. In particular, groundwater chemistry seems to evolve from bicarbonate to sodium facies. Moreover, the gradient of concentrations vary depending on fault locations and can be related to their hydraulic properties and hence to different characteristic times from point to point. To conclude, major faults across the site display different degrees of groundwater chemistry evolution, linked to their physical properties, which may in turn have a large impact on contaminant transport and attenuation.

  9. Quantification of air plasma chemistry for surface disinfection

    NASA Astrophysics Data System (ADS)

    Pavlovich, Matthew J.; Clark, Douglas S.; Graves, David B.

    2014-12-01

    Atmospheric-pressure air plasmas, created by a variety of discharges, are promising sources of reactive species for the emerging field of plasma biotechnology because of their convenience and ability to operate at ambient conditions. One biological application of ambient-air plasma is microbial disinfection, and the ability of air plasmas to decontaminate both solid surfaces and liquid volumes has been thoroughly established in the literature. However, the mechanism of disinfection and which reactive species most strongly correlate with antimicrobial effects are still not well understood. We describe quantitative gas-phase measurements of plasma chemistry via infrared spectroscopy in confined volumes, focusing on air plasma generated via surface micro-discharge (SMD). Previously, it has been shown that gaseous chemistry is highly sensitive to operating conditions, and the measurements we describe here extend those findings. We quantify the gaseous concentrations of ozone (O3) and nitrogen oxides (NO and NO2, or NOx) throughout the established ‘regimes’ for SMD air plasma chemistry: the low-power, ozone-dominated mode; the high-power, nitrogen oxides-dominated mode; and the intermediate, unstable transition region. The results presented here are in good agreement with previously published experimental studies of aqueous chemistry and parameterized models of gaseous chemistry. The principal finding of the present study is the correlation of bacterial inactivation on dry surfaces with gaseous chemistry across these time and power regimes. Bacterial decontamination is most effective in ‘NOx mode’ and less effective in ‘ozone mode’, with the weakest antibacterial effects in the transition region. Our results underscore the dynamic nature of air plasma chemistry and the importance of careful chemical characterization of plasma devices intended for biological applications.

  10. The effect of point-of-care personal digital assistant use on resident documentation discrepancies.

    PubMed

    Carroll, Aaron E; Tarczy-Hornoch, Peter; O'Reilly, Eamon; Christakis, Dimitri A

    2004-03-01

    We recently found documentation discrepancies in 60% of resident daily-progress notes with respect to patient weight, medications, or vascular lines. To what extent information systems can decrease such discrepancies is unknown. To determine whether a point-of-care personal digital assistant (PDA)-based patient record and charting system could reduce the number of resident progress-note documentation discrepancies in a neonatal intensive care unit (NICU). We conducted a before-and-after trial in an academic NICU. Our intervention was a PDA-based patient record and charting system used by all NICU resident physicians over the study period. We analyzed all resident daily-progress notes from 40 randomly selected days over 4 months in both the baseline and intervention periods. Using predefined reference standards, we determined the accuracy of recorded information for patient weights, medications, and vascular lines. Logistic and Poisson regression were used in analyses to control for potential confounding factors. A total of 339 progress notes in the baseline period and 432 progress notes in the intervention period were reviewed. When controlling for covariates in the regression, there were significantly fewer documentation discrepancies of patient weights in notes written by using the PDA system (14.4%-4.4% of notes; odds ratio [OR]: 0.29; 95% confidence interval [CI]: 0.15-0.56). When using the PDA system, there were no significant changes in the numbers of notes with documentation discrepancies of medications (27.7%-17.1% of notes; OR: 0.63; 95% CI: 0.35-1.13) or vascular lines (33.6%-36.1% of notes; OR: 1.11; 95% CI: 0.66-1.87). The use of our PDA-based point-of-care patient record and charting system showed a modest benefit in reducing the number of documentation discrepancies in resident daily-progress notes. Further study of PDAs in information systems is warranted before they are widely adopted.

  11. Significant steps in the evolution of analytical chemistry--is the today's analytical chemistry only chemistry?

    PubMed

    Karayannis, Miltiades I; Efstathiou, Constantinos E

    2012-12-15

    In this review the history of chemistry and specifically the history and the significant steps of the evolution of analytical chemistry are presented. In chronological time spans, covering the ancient world, the middle ages, the period of the 19th century, and the three evolutional periods, from the verge of the 19th century to contemporary times, it is given information for the progress of chemistry and analytical chemistry. During this period, analytical chemistry moved gradually from its pure empirical nature to more rational scientific activities, transforming itself to an autonomous branch of chemistry and a separate discipline. It is also shown that analytical chemistry moved gradually from the status of exclusive serving the chemical science, towards serving, the environment, health, law, almost all areas of science and technology, and the overall society. Some recommendations are also directed to analytical chemistry educators concerning the indispensable nature of knowledge of classical analytical chemistry and the associated laboratory exercises and to analysts, in general, why it is important to use the chemical knowledge to make measurements on problems of everyday life. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Nano-Calorimetry based point of care biosensor for metabolic disease management.

    PubMed

    Kazura, Evan; Lubbers, Brad R; Dawson, Elliott; Phillips, John A; Baudenbacher, Franz

    2017-09-01

    Point of care (POC) diagnostics represents one of the fastest growing health care technology segments. Developments in microfabrication have led to the development of highly-sensitive nanocalorimeters ideal for directly measuring heat generated in POC biosensors. Here we present a novel nano-calorimeter-based biosensor design with differential sensing to eliminate common mode noise and capillary microfluidic channels for sample delivery to the thermoelectric sensor. The calorimeter has a resolution of 1.4 ± 0.2 nJ/(Hz) 1/2 utilizing a 27 junction bismuth/titanium thermopile, with a total Seebeck coefficient of 2160 μV/K. Sample is wicked to the calorimeter through a capillary channel making it suitable for monitoring blood obtained through a finger prick (<1 μL sample required). We demonstrate device performance in a model assay using catalase, achieving a threshold for hydrogen peroxide quantification of 50 μM. The potential for our device as a POC blood test for metabolic diseases is shown through the quantification of phenylalanine (Phe) in serum, an unmet necessary service in the management of Phenylketonuria (PKU). Pegylated phenylalanine ammonia-lyase (PEG-PAL) was utilized to react with Phe, but reliable detection was limited to <5 mM due to low enzymatic activity. The POC biosensor concept can be multiplexed and adapted to a large number of metabolic diseases utilizing different immobilized enzymes.

  13. An observational study to assess an electronic point-of-care wound documentation and reporting system regarding user satisfaction and potential for improved care.

    PubMed

    Florczak, Beth; Scheurich, Anne; Croghan, John; Sheridan, Philip; Kurtz, Debra; McGill, William; McClain, Bonny

    2012-03-01

    The integration of information technology into daily patient care potentially provides a means to standardize care and enable continuous quality improvement through improved communication among care teams. A 2-month observational study was conducted on 38 residents with pressure ulcers at a 51-bed skilled nursing facility to rate the Ease of Use and Wound Management Effectiveness of a point-of-care electronic wound documentation system. Nine nurses evaluated the use of handheld "smart phone" devices equipped with a digital camera to document pressure ulcer assessment and treatment at point of care. Ease of Use (five items) was scored on a 5-point Likert scale (5 = very easy); Wound Management Effectiveness (eight items) was scored on a 5-point Likert scale (5 = very effective). Statistically significant mean changes in nurses' ratings were found for baseline compared to 2-month follow-up by paired t-test. Ease of Use ratings across the five criteria increased from an overall mean of 3.3 at baseline to 4.7 at follow-up (P = 0.5), while Wound Management Effectiveness increased from an overall mean of 3.3 at baseline to 4.4 at follow-up (P = 0.5) . The greatest gains for single items were reviewing wound progress (mean difference = 2.35; P = 0.000) and recognizing changes in wound status (mean difference = 1.78; P = 0.001) within the Ease of Use and Wound Management Effectiveness scales, respectively. The smallest change occurred in reading charts and notes (mean difference = 0.89) and ability to determine resident's risk level (mean difference = 0.39). Further research is needed to assess use of a wound documentation system in this and other settings, as well as to ascertain validity and reliability.

  14. Point-of-care Beta-lactam Allergy Skin Testing by Antimicrobial Stewardship Programs: A Pragmatic Multicenter Prospective Evaluation.

    PubMed

    Leis, Jerome A; Palmay, Lesley; Ho, Grace; Raybardhan, Sumit; Gill, Suzanne; Kan, Tiffany; Campbell, Jackie; Kiss, Alex; McCready, Janine B; Das, Pavani; Minnema, Brian; Powis, Jeff E; Walker, Sandra A N; Ferguson, Heather; Wong, Benny; Weber, Elizabeth

    2017-06-01

    Beta-lactam allergy skin testing (BLAST) is recommended by antimicrobial stewardship program (ASP) guidelines, yet few studies have systematically evaluated its impact when delivered at point-of-care. We conducted a pragmatic multicenter prospective evaluation of the use of point-of-care BLAST by ASPs. In staggered 3-month intervals, ASP teams at three hospitals received training by allergists to offer BLAST for eligible patients with infectious diseases receiving non-preferred beta-lactam therapy due to severity of their allergy. The primary outcome was the proportion of patients receiving the preferred beta-lactam therapy. Of 827 patients with reported beta-lactam allergy over 15-months, beta-lactam therapy was preferred among 632(76%). During baseline periods, 50% (124/246) received preferred beta-lactam therapy based on history, compared with 60% (232/386) during the intervention periods (p=0.02), which improved further to 81% (313/386) upon provision of BLAST (p<0.001) without any increase in incidence of adverse drug reactions (4% vs. 3%; p=0.4). After adjusting for patient variables and the correlation between hospitals, the intervention period was associated with a 4.5-fold greater odds of receiving preferred beta-lactam therapy (95% CI, 2.4-8.2; p<0.0001). The use of BLAST at the point-of-care across three hospital ASPs resulted in greater use of preferred beta-lactam therapy without increasing the risk of adverse drug reactions. Longer term studies are needed to better assess the safety and clinical impact of this ASP intervention. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  15. Point-of-care ultrasound (POCUS): unnecessary gadgetry or evidence-based medicine?

    PubMed

    Smallwood, Nicholas; Dachsel, Martin

    2018-06-01

    Over the last decade there has been increasing interest and enthusiasm in point-of-care ultrasound (POCUS) as an aide to traditional examination techniques in assessing acutely unwell adult patients. However, it currently remains the domain of a relatively small handful of physicians within the UK. There are numerous reasons for this, notably a lack of training pathways and supervisors but also a lack of understanding of the evidence base behind this imaging modality. This review article aims to explore some of the evidence base behind POCUS for a number of medical pathologies, and where possible compare it to evidenced traditional examination techniques. We discuss the issues around training in bedside ultrasound and recommend a push to integrate POCUS training into internal medicine curricula and support trainers to comprehensively deliver this. © Royal College of Physicians 2018. All rights reserved.

  16. Hypertrophic Cardiomyopathy in Youth Athletes: Successful Screening With Point-of-Care Ultrasound by Medical Students.

    PubMed

    Fox, J Christian; Lahham, Shadi; Maldonado, Graciela; Klaus, Suzi; Aish, Bassil; Sylwanowicz, Lauren V; Yanuck, Justin; Wilson, Sean P; Shieh, Mason; Anderson, Craig L; English, Carter; Mayer, Ryan; Mohan, Uthara R

    2017-06-01

    Hypertrophic cardiomyopathy (HCM) is a life-threatening genetic cardiovascular disease that often goes undetected in young athletes. Neither history nor physical examination are reliable to identify those at risk. The objective of this study is to determine whether minimally trained medical student volunteers can use ultrasound to screen for HCM. This was a prospective enrollment of young athletes performed at 12 area high schools and three area colleges, between May 2012 and August 2013. All participants underwent point-of-care ultrasound performed screening for HCM by trained medical students and reviewed by a pediatric cardiologist. An interventricular septum to left ventricular posterior wall ratio greater than 1.25 was considered to be abnormal (positive screen). A total of 2332 participants were enrolled. There were 137 (5.8%) with a positive screening for HCM, of which 7 (5.1%) were confirmed to have HCM by a pediatric cardiologist. In a small cohort with positive screen for HCM, there was a 100% sensitivity (95% confidence interval, 59.04 to 100%) and 4.86% (95% confidence interval, 1.98 to 9.76%) positive predictive value of for having HCM. Volunteer medical students, using point-of-care ultrasound, were able to effectively screen for HCM in young athletes. © 2017 by the American Institute of Ultrasound in Medicine.

  17. Adapting a large database of point of care summarized guidelines: a process description.

    PubMed

    Delvaux, Nicolas; Van de Velde, Stijn; Aertgeerts, Bert; Goossens, Martine; Fauquert, Benjamin; Kunnamo, Ilka; Van Royen, Paul

    2017-02-01

    Questions posed at the point of care (POC) can be answered using POC summarized guidelines. To implement a national POC information resource, we subscribed to a large database of POC summarized guidelines to complement locally available guidelines. Our challenge was in developing a sustainable strategy for adapting almost 1000 summarized guidelines. The aim of this paper was to describe our process for adapting a database of POC summarized guidelines. An adaptation process based on the ADAPTE framework was tailored to be used by a heterogeneous group of participants. Guidelines were assessed on content and on applicability to the Belgian context. To improve efficiency, we chose to first aim our efforts towards those guidelines most important to primary care doctors. Over a period of 3 years, we screened about 80% of 1000 international summarized guidelines. For those guidelines identified as most important for primary care doctors, we noted that in about half of the cases, remarks were made concerning content. On the other hand, at least two-thirds of all screened guidelines required no changes when evaluating their local usability. Adapting a large body of POC summarized guidelines using a formal adaptation process is possible, even when faced with limited resources. This can be done by creating an efficient and collaborative effort and ensuring user-friendly procedures. Our experiences show that even though in most cases guidelines can be adopted without adaptations, careful review of guidelines developed in a different context remains necessary. Streamlining international efforts in adapting international POC information resources and adopting similar adaptation processes may lessen duplication efforts and prove more cost-effective. © 2015 The Authors. Journal of Evaluation in Clinical Practice published by John Wiley & Sons, Ltd.

  18. The Eighth Central European Conference "Chemistry towards Biology": Snapshot.

    PubMed

    Perczel, András; Atanasov, Atanas G; Sklenář, Vladimír; Nováček, Jiří; Papoušková, Veronika; Kadeřávek, Pavel; Žídek, Lukáš; Kozłowski, Henryk; Wątły, Joanna; Hecel, Aleksandra; Kołkowska, Paulina; Koča, Jaroslav; Svobodová-Vařeková, Radka; Pravda, Lukáš; Sehnal, David; Horský, Vladimír; Geidl, Stanislav; Enriz, Ricardo D; Matějka, Pavel; Jeništová, Adéla; Dendisová, Marcela; Kokaislová, Alžběta; Weissig, Volkmar; Olsen, Mark; Coffey, Aidan; Ajuebor, Jude; Keary, Ruth; Sanz-Gaitero, Marta; van Raaij, Mark J; McAuliffe, Olivia; Waltenberger, Birgit; Mocan, Andrei; Šmejkal, Karel; Heiss, Elke H; Diederich, Marc; Musioł, Robert; Košmrlj, Janez; Polański, Jarosław; Jampílek, Josef

    2016-10-17

    The Eighth Central European Conference "Chemistry towards Biology" was held in Brno, Czech Republic, on August 28-September 1, 2016 to bring together experts in biology, chemistry and design of bioactive compounds; promote the exchange of scientific results, methods and ideas; and encourage cooperation between researchers from all over the world. The topics of the conference covered "Chemistry towards Biology", meaning that the event welcomed chemists working on biology-related problems, biologists using chemical methods, and students and other researchers of the respective areas that fall within the common scope of chemistry and biology. The authors of this manuscript are plenary speakers and other participants of the symposium and members of their research teams. The following summary highlights the major points/topics of the meeting.

  19. Implementation of Point-of-Care Diagnostics Leads to Variable Uptake of Syphilis, Anemia and CD4+ T-Cell Count Testing in Rural Maternal and Child Health Clinics.

    PubMed

    De Schacht, Caroline; Lucas, Carlota; Sitoe, Nádia; Machekano, Rhoderick; Chongo, Patrina; Temmerman, Marleen; Tobaiwa, Ocean; Guay, Laura; Kassaye, Seble; Jani, Ilesh V

    2015-01-01

    Anemia, syphilis and HIV are high burden diseases among pregnant women in sub-Saharan Africa. A quasi-experimental study was conducted in four health facilities in Southern Mozambique to evaluate the effect of point-of-care technologies for hemoglobin quantification, syphilis testing and CD4+ T-cell enumeration performed within maternal and child health services on testing and treatment coverage, and assessing acceptability by health workers. Demographic and testing data on women attending first antenatal care services were extracted from existing records, before (2011; n = 865) and after (2012; n = 808) introduction of point-of-care testing. Study outcomes per health facility were compared using z-tests (categorical variables) and Wilcoxon rank-sum test (continuous variables), while inverse variance weights were used to adjust for possible cluster effects in the pooled analysis. A structured acceptability-assessment interview was conducted with health workers before (n = 22) and after (n = 19). After implementation of point-of-care testing, there was no significant change in uptake of overall hemoglobin screening (67.9% to 83.0%; p = 0.229), syphilis screening (80.8% to 87.0%; p = 0.282) and CD4+ T-cell testing (84.9% to 83.5%; p = 0.930). Initiation of antiretroviral therapy for treatment eligible women was similar in the weighted analysis before and after, with variability among the sites. Time from HIV diagnosis to treatment initiation decreased (median of 44 days to 17 days; p<0.0001). A generally good acceptability for point-of-care testing was seen among health workers. Point-of-care CD4+ T-cell enumeration resulted in a decreased time to initiation of antiretroviral therapy among treatment eligible women, without significant increase in testing coverage. Overall hemoglobin and syphilis screening increased. Despite the perception that point-of-care technologies increase access to health services, the variability in results indicate the potential for

  20. Phase Equilibrium, Chemical Equilibrium, and a Test of the Third Law: Experiments for Physical Chemistry.

    ERIC Educational Resources Information Center

    Dannhauser, Walter

    1980-01-01

    Described is an experiment designed to provide an experimental basis for a unifying point of view (utilizing theoretical framework and chemistry laboratory experiments) for physical chemistry students. Three experiments are described: phase equilibrium, chemical equilibrium, and a test of the third law of thermodynamics. (Author/DS)

  1. A spatial and seasonal assessment of river water chemistry across North West England.

    PubMed

    Rothwell, J J; Dise, N B; Taylor, K G; Allott, T E H; Scholefield, P; Davies, H; Neal, C

    2010-01-15

    This paper presents information on the spatial and seasonal patterns of river water chemistry at approximately 800 sites in North West England based on data from the Environment Agency regional monitoring programme. Within a GIS framework, the linkages between average water chemistry (pH, sulphate, base cations, nutrients and metals) catchment characteristics (topography, land cover, soil hydrology, base flow index and geology), rainfall, deposition chemistry and geo-spatial information on discharge consents (point sources) are examined. Water quality maps reveal that there is a clear distinction between the uplands and lowlands. Upland waters are acidic and have low concentrations of base cations, explained by background geological sources and land cover. Localised high concentrations of metals occur in areas of the Cumbrian Fells which are subjected to mining effluent inputs. Nutrient concentrations are low in the uplands with the exception sites receiving effluent inputs from rural point sources. In the lowlands, both past and present human activities have a major impact on river water chemistry, especially in the urban and industrial heartlands of Greater Manchester, south Lancashire and Merseyside. Over 40% of the sites have average orthophosphate concentrations >0.1mg-Pl(-1). Results suggest that the dominant control on orthophosphate concentrations is point source contributions from sewage effluent inputs. Diffuse agricultural sources are also important, although this influence is masked by the impact of point sources. Average nitrate concentrations are linked to the coverage of arable land, although sewage effluent inputs have a significant effect on nitrate concentrations. Metal concentrations in the lowlands are linked to diffuse and point sources. The study demonstrates that point sources, as well as diffuse sources, need to be considered when targeting measures for the effective reduction in river nutrient concentrations. This issue is clearly important

  2. ARINC 818 express for high-speed avionics video and power over coax

    NASA Astrophysics Data System (ADS)

    Keller, Tim; Alexander, Jon

    2012-06-01

    CoaXPress is a new standard for high-speed video over coax cabling developed for the machine vision industry. CoaXPress includes both a physical layer and a video protocol. The physical layer has desirable features for aerospace and defense applications: it allows 3Gbps (up to 6Gbps) communication, includes 21Mbps return path allowing for bidirectional communication, and provides up to 13W of power, all over a single coax connection. ARINC 818, titled "Avionics Digital Video Bus" is a protocol standard developed specifically for high speed, mission critical aerospace video systems. ARINC 818 is being widely adopted for new military and commercial display and sensor applications. The ARINC 818 protocol combined with the CoaXPress physical layer provide desirable characteristics for many aerospace systems. This paper presents the results of a technology demonstration program to marry the physical layer from CoaXPress with the ARINC 818 protocol. ARINC 818 is a protocol, not a physical layer. Typically, ARINC 818 is implemented over fiber or copper for speeds of 1 to 2Gbps, but beyond 2Gbps, it has been implemented exclusively over fiber optic links. In many rugged applications, a copper interface is still desired, by implementing ARINC 818 over the CoaXPress physical layer, it provides a path to 3 and 6 Gbps copper interfaces for ARINC 818. Results of the successful technology demonstration dubbed ARINC 818 Express are presented showing 3Gbps communication while powering a remote module over a single coax cable. The paper concludes with suggested next steps for bring this technology to production readiness.

  3. The feasibility of point-of-care ankle ultrasound examination in patients with recurrent ankle sprain and chronic ankle instability: Comparison with magnetic resonance imaging.

    PubMed

    Lee, Sun Hwa; Yun, Seong Jong

    2017-10-01

    To evaluate the feasibility of point-of-care ankle ultrasound compared with magnetic resonance imaging (MRI) for diagnosing major ligaments and Achilles tendon injuries in patients with recurrent ankle sprain and chronic instability, and to evaluate inter-observer reliability between an emergency physician and a musculoskeletal radiology fellow. A prospective cross-sectional study was conducted in an emergency department. Patients with recurrent ankle sprain and chronic instability were recruited. An emergency physician and a musculoskeletal radiology fellow independently evaluated the anterior talofibular ligament (ATFL), calcaneofibular ligament (CFL), distal anterior tibiofibular ligament (ATiFL), deltoid ligament, and Achilles tendon using point-of-care ankle ultrasound. Findings were classified normal, partial tear, and complete tear. MRI was used as the reference standard. We calculated diagnostic values for point-of-care ankle ultrasound for both reviewers and compared them using DeLong's test. Intra-class correlation coefficients (ICCs) were calculated for agreement between each reviewer and the reference standard, and between the two reviewers. Eighty-five patients were enrolled. Point-of-care ankle ultrasound showed acceptable sensitivity (96.4-100%), specificity (95.0-100%), and accuracy (96.5-100%); these performance markers did not differ significantly between reviewers. Agreement between each reviewer and the reference standard was excellent (emergency physician, ICC=0.846-1.000; musculoskeletal radiology fellow, ICC=0.930-1.000), as was inter-observer agreement (ICC=0.873-1.000). Point-of-care ankle ultrasound is as precise as MRI for detecting major ankle ligament and Achilles tendon injuries; it could be used for immediate diagnosis and further pre-operative imaging. Moreover, it may reduce the interval from emergency department admission to admission for surgical intervention, and may save costs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Geology of Nicholson's point granite, Natal Metamorphic Province, South Africa: the chemistry of charnockitic alteration and origin of the granite

    NASA Astrophysics Data System (ADS)

    Grantham, G. H.; Allen, A. R.; Cornell, D. H.; Harris, C.

    1996-10-01

    In the Port Edward area of southern Kwa-Zulu Natal, South Africa, charnockitic aureoles up to ˜4 m in width are developed adjacent to contacts with Port Edward enderbite and pegmatites intruded into the normally garnetiferous Nicholson's Point granite. Other mineralogical differences between the aureoles and the granite include increased myrmekite and significantly less biotite in the former and the replacement of pyrite by pyrrhotite in the charnockitic rocks. No significant differences in major element chemistry between the garnet-biotite Nicholson's Point granite and charnockitic Nicholson's Point granite are seen, except possibly for higher CaO and TiO 2 in the charnockite. Higher Rb, Th, Nb and Y contents in the garnet-biotite granite suggest that these elements have been locally depleted from garnet-biotite granite during char nockitisation. This depletion is considered to be related to the reduction in biotite. Strontium and Ba contents are significantly higher in the charnockite. Generally higher S contents in the charnockite suggest S metasomatism, with S possibly being added from the enderbite. No differences in δ18O isotope data are seen between the garnetiferous and hypersthene bearing granite. In the charnockite the LREEs are weakly depleted whereas the HREEs show greater depletion compared to the garnetiferous granite. The depletions in REEs are thought to be related to the breakdown of garnet. Europium is marginally enriched or unchanged in the charnockite relative to the garnetiferous granite. Two-pyroxene thermometry on the Port Edward enderbite suggests that it was intruded at temperatures of ˜1000-1100°C. The replacement of pyrite by pyrrhotite is also consistent with a thermal auroele. Consequently the charnockitic zones developed around the intrusions of Port Edward enderbite may result from the thermally driven dehydration of biotite. The aureoles developed adjacent to pegmatites are not considered to have resulted from heat but probably

  5. Access and Quality of HIV-Related Point-of-Care Diagnostic Testing in Global Health Programs.

    PubMed

    Fonjungo, Peter N; Boeras, Debrah I; Zeh, Clement; Alexander, Heather; Parekh, Bharat S; Nkengasong, John N

    2016-02-01

    Access to point-of-care testing (POCT) improves patient care, especially in resource-limited settings where laboratory infrastructure is poor and the bulk of the population lives in rural settings. However, because of challenges in rolling out the technology and weak quality assurance measures, the promise of human immunodeficiency virus (HIV)-related POCT in resource-limited settings has not been fully exploited to improve patient care and impact public health. Because of these challenges, the Joint United Nations Programme on HIV/AIDS (UNAIDS), in partnership with other organizations, recently launched the Diagnostics Access Initiative. Expanding HIV programs, including the "test and treat" strategies and the newly established UNAIDS 90-90-90 targets, will require increased access to reliable and accurate POCT results. In this review, we examine various components that could improve access and uptake of quality-assured POC tests to ensure coverage and public health impact. These components include evaluation, policy, regulation, and innovative approaches to strengthen the quality of POCT. © The Author 2015. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  6. From supramolecular chemistry towards constitutional dynamic chemistry and adaptive chemistry.

    PubMed

    Lehn, Jean-Marie

    2007-02-01

    Supramolecular chemistry has developed over the last forty years as chemistry beyond the molecule. Starting with the investigation of the basis of molecular recognition, it has explored the implementation of molecular information in the programming of chemical systems towards self-organisation processes, that may occur either on the basis of design or with selection of their components. Supramolecular entities are by nature constitutionally dynamic by virtue of the lability of non-covalent interactions. Importing such features into molecular chemistry, through the introduction of reversible bonds into molecules, leads to the emergence of a constitutional dynamic chemistry, covering both the molecular and supramolecular levels. It considers chemical objects and systems capable of responding to external solicitations by modification of their constitution through component exchange or reorganisation. It thus opens the way towards an adaptive and evolutive chemistry, a further step towards the chemistry of complex matter.

  7. Health care sensor--based systems for point of care monitoring and diagnostic applications: a brief survey.

    PubMed

    Tsakalakis, Michail; Bourbakis, Nicolaos G

    2014-01-01

    Continuous, real-time remote monitoring through medical point--of--care (POC) systems appears to draw the interest of the scientific community for healthcare monitoring and diagnostic applications the last decades. Towards this direction a significant merit has been due to the advancements in several scientific fields. Portable, wearable and implantable apparatus may contribute to the betterment of today's healthcare system which suffers from fundamental hindrances. The number and heterogeneity of such devices and systems regarding both software and hardware components, i.e sensors, antennas, acquisition circuits, as well as the medical applications that are designed for, is impressive. Objective of the current study is to present the major technological advancements that are considered to be the driving forces in the design of such systems, to briefly state the new aspects they can deliver in healthcare and finally, the identification, categorization and a first level evaluation of them.

  8. Advances in Candida detection platforms for clinical and point-of-care applications

    PubMed Central

    Safavieh, Mohammadali; Coarsey, Chad; Esiobu, Nwadiuto; Memic, Adnan; Vyas, Jatin Mahesh; Shafiee, Hadi; Asghar, Waseem

    2016-01-01

    Invasive candidiasis remains one of the most serious community and healthcare-acquired infections worldwide. Conventional Candida detection methods based on blood and plate culture are time-consuming and require at least 2–4 days to identify various Candida species. Despite considerable advances for candidiasis detection, the development of simple, compact and portable point-of-care diagnostics for rapid and precise testing that automatically performs cell lysis, nucleic acid extraction, purification and detection still remains a challenge. Here, we systematically review most prominent conventional and nonconventional techniques for the detection of various Candida species, including Candida staining, blood culture, serological testing and nucleic acid-based analysis. We also discuss the most advanced lab on a chip devices for candida detection. PMID:27093473

  9. Synthesis and Metalation of a Ligand: An Interdisciplinary Laboratory Experiment for Second-Year Organic and Introductory Inorganic Chemistry Students

    ERIC Educational Resources Information Center

    Kasting, Benjamin J.; Bowser, Andrew K.; Anderson-Wile, Amelia M.; Wile, Bradley M.

    2015-01-01

    An interdisciplinary laboratory experiment involving second-year undergraduate organic chemistry and introductory inorganic chemistry undergraduate students is described. Organic chemistry students prepare a series of amine-bis(phenols) via a Mannich reaction, and characterize their products using melting point; FTIR; and [superscript 1]H,…

  10. Scenario-Based Assessment of User Needs for Point-of-Care Robots

    PubMed Central

    Lee, Hyeong Suk

    2018-01-01

    Objectives This study aimed to derive specific user requirements and barriers in a real medical environment to define the essential elements and functions of two types of point-of-care (POC) robot: a telepresence robot as a tool for teleconsultation, and a bedside robot to provide emotional care for patients. Methods An analysis of user requirements was conducted; user needs were gathered and identified, and detailed, realistic scenarios were created. The prototype robots were demonstrated in physical environments for envisioning and evaluation. In all, three nurses and three clinicians participated as evaluators to observe the demonstrations and evaluate the robot systems. The evaluators were given a brief explanation of each scene and the robots' functionality. Four major functions of the teleconsultation robot were defined and tested in the demonstration. In addition, four major functions of the bedside robot were evaluated. Results Among the desired functions for a teleconsultation robot, medical information delivery and communication had high priority. For a bedside robot, patient support, patient monitoring, and healthcare provider support were the desired functions. The evaluators reported that the teleconsultation robot can increase support from and access to specialists and resources. They mentioned that the bedside robot can improve the quality of hospital life. Problems identified in the demonstration were those of space conflict, communication errors, and safety issues. Conclusions Incorporating this technology into healthcare services will enhance communication and teamwork skills across distances and thereby facilitate teamwork. However, repeated tests will be needed to evaluate and ensure improved performance. PMID:29503748

  11. Teaching Green Chemistry with Epoxidized Soybean Oil

    ERIC Educational Resources Information Center

    Barcena, Homar; Tuachi, Abraham; Zhang, Yuanzhuo

    2017-01-01

    The synthesis of epoxidized soybean oil (ESO) provides students a vantage point on the application of green chemistry principles in a series of experiments. Qualitative tests review the reactions of alkenes, whereas spectroscopic analyses provide insight in monitoring functional group transformations.

  12. How can point-of-care HbA1c testing be integrated into UK primary care consultations? - A feasibility study.

    PubMed

    Hirst, J A; Stevens, R J; Smith, I; James, T; Gudgin, B C; Farmer, A J

    2017-08-01

    Point-of-care (POC) HbA1c testing gives a rapid result, allowing testing and treatment decisions to take place in a single appointment. Trials of POC testing have not been shown to improve HbA1c, possibly because of how testing was implemented. This study aimed to identify key components of POC HbA1c testing and determine strategies to optimise implementation in UK primary care. This cohort feasibility study recruited thirty patients with type 2 diabetes and HbA1c>7.5% (58mmol/mol) into three primary care clinics. Patients' clinical care included two POC HbA1c tests over six months. Data were collected on appointment duration, clinical decisions, technical performance and patient behaviour. Fifty-three POC HbA1c consultations took place during the study; clinical decisions were made in 30 consultations. Five POC consultations with a family doctor lasted on average 11min and 48 consultations with nurses took on average 24min. Five POC study visits did not take place in one clinic. POC results were uploaded to hospital records from two clinics. In total, sixty-three POC tests were performed, and there were 11 cartridge failures. No changes in HbA1c or patient behaviour were observed. HbA1c measurement with POC devices can be effectively implemented in primary care. This work has identified when these technologies might work best, as well as potential challenges. The findings can be used to inform the design of a pragmatic trial to implement POC HbA1c testing. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Assessment of a Novel Point-of-Care Ultrasound Curriculum's Effect on Competency Measures in Family Medicine Graduate Medical Education.

    PubMed

    Bornemann, Paul

    2017-06-01

    Point-of-care ultrasound has been shown to decrease the use of expensive diagnostic studies and improve quality outcome measures. Currently, there is a large desire for training in family medicine residencies, but very few programs have established curricula. We sought to develop a family medicine residency curriculum and evaluate it with tools we developed. We wanted our curriculum to be easy to adopt by other residency programs, even if they did not have many well-trained ultrasound faculty. We developed a curriculum in the form of a 4-week rotation in a family medicine residency program. It consisted of self-study videos, hands-on training, and image review. We followed residents in postgraduate years 1 to 3 over a 12-month period. We developed tools, including a knowledge exam, to test image interpretation and clinical decision making, an observed structured clinical exam to assess scanning skills, and a survey to assess perceptions of point-of-care ultrasound in family medicine. The assessments were administered before and after each resident's rotation. Seventeen residents completed the rotation. The average knowledge test score improved significantly, from 62 to 84%. The average observed structured clinical exam scores also improved significantly, from 41 to 85%. The average perception survey scores improved slightly from 4.4 to 4.6. We developed a point-of-care ultrasound curriculum for family medicine residency programs that improves measures of resident attitude, skills, and knowledge. This curriculum can be adopted by residency programs with few faculty members who are experienced in ultrasound. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Augmenting epidemiological models with point-of-care diagnostics data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pullum, Laura L.; Ramanathan, Arvind; Nutaro, James J.

    Although adoption of newer Point-of-Care (POC) diagnostics is increasing, there is a significant challenge using POC diagnostics data to improve epidemiological models. In this work, we propose a method to process zip-code level POC datasets and apply these processed data to calibrate an epidemiological model. We specifically develop a calibration algorithm using simulated annealing and calibrate a parsimonious equation-based model of modified Susceptible-Infected-Recovered (SIR) dynamics. The results show that parsimonious models are remarkably effective in predicting the dynamics observed in the number of infected patients and our calibration algorithm is sufficiently capable of predicting peak loads observed in POC diagnosticsmore » data while staying within reasonable and empirical parameter ranges reported in the literature. Additionally, we explore the future use of the calibrated values by testing the correlation between peak load and population density from Census data. Our results show that linearity assumptions for the relationships among various factors can be misleading, therefore further data sources and analysis are needed to identify relationships between additional parameters and existing calibrated ones. As a result, calibration approaches such as ours can determine the values of newly added parameters along with existing ones and enable policy-makers to make better multi-scale decisions.« less

  15. Augmenting epidemiological models with point-of-care diagnostics data

    DOE PAGES

    Pullum, Laura L.; Ramanathan, Arvind; Nutaro, James J.; ...

    2016-04-20

    Although adoption of newer Point-of-Care (POC) diagnostics is increasing, there is a significant challenge using POC diagnostics data to improve epidemiological models. In this work, we propose a method to process zip-code level POC datasets and apply these processed data to calibrate an epidemiological model. We specifically develop a calibration algorithm using simulated annealing and calibrate a parsimonious equation-based model of modified Susceptible-Infected-Recovered (SIR) dynamics. The results show that parsimonious models are remarkably effective in predicting the dynamics observed in the number of infected patients and our calibration algorithm is sufficiently capable of predicting peak loads observed in POC diagnosticsmore » data while staying within reasonable and empirical parameter ranges reported in the literature. Additionally, we explore the future use of the calibrated values by testing the correlation between peak load and population density from Census data. Our results show that linearity assumptions for the relationships among various factors can be misleading, therefore further data sources and analysis are needed to identify relationships between additional parameters and existing calibrated ones. As a result, calibration approaches such as ours can determine the values of newly added parameters along with existing ones and enable policy-makers to make better multi-scale decisions.« less

  16. A Study on Amino Acids: Synthesis of Alpha-Aminophenylacetic Acid (Phenylglycine) and Determination of its Isoelectric Point.

    ERIC Educational Resources Information Center

    Barrelle, M.; And Others

    1983-01-01

    Background information and procedures are provided for an experimental study on aminophenylacetic acid (phenylglycine). These include physical chemistry (determination of isoelectric point by pH measurement) and organic chemistry (synthesis of an amino acid in racemic form) experiments. (JN)

  17. Robust ultrasensitive tunneling-FET biosensor for point-of-care diagnostics

    PubMed Central

    Gao, Anran; Lu, Na; Wang, Yuelin; Li, Tie

    2016-01-01

    For point-of-care (POC) applications, robust, ultrasensitive, small, rapid, low-power, and low-cost sensors are highly desirable. Here, we present a novel biosensor based on a complementary metal oxide semiconductor (CMOS)-compatible silicon nanowire tunneling field-effect transistor (SiNW-TFET). They were fabricated “top-down” with a low-cost anisotropic self-stop etching technique. Notably, the SiNW-TFET device provided strong anti-interference capacity by applying the inherent ambipolarity via both pH and CYFRA21-1 sensing. This offered a more robust and portable general protocol. The specific label-free detection of CYFRA21-1 down to 0.5 fgml−1 or ~12.5 aM was achieved using a highly responsive SiNW-TFET device with a minimum sub-threshold slope (SS) of 37 mVdec−1. Furthermore, real-time measurements highlighted the ability to use clinically relevant samples such as serum. The developed high performance diagnostic system is expected to provide a generic platform for numerous POC applications. PMID:26932158

  18. Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings

    PubMed Central

    Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V

    2014-01-01

    Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389

  19. Anaesthesiologists' views on the need for point-of-care information system in the operating room: a survey of the European Society of Anaesthesiologists.

    PubMed

    Perel, A; Berkenstadt, H; Ziv, A; Katzenelson, R; Aitkenhead, A

    2004-11-01

    In this preliminary study we wanted to explore the attitudes of anaesthesiologists to a point-of-care information system in the operating room. The study was conducted as a preliminary step in the process of developing such a system by the European Society of Anaesthesiologists (ESA). A questionnaire was distributed to all 2240 attendees of the ESA's annual meeting in Gothenburg, Sweden, which took place in April 2001. Of the 329 responders (response rate of 14.6%), 79% were qualified specialists with more than 10 yr of experience (68%), mostly from Western Europe. Most responders admitted to regularly experiencing lack of medical knowledge relating to real-time patient care at least once a month (74%) or at least once a week (46%), and 39% admitted to having made errors during anaesthesia due to lack of medical information that can be otherwise found in a handbook. The choice ofa less optimal but more familiar approach to patient management due to lack of knowledge was reported by 37%. Eighty-eight percent of responders believe that having a point-of-care information system for the anaesthesiologists in the operating room is either important or very important. This preliminary survey demonstrates that lack of knowledge of anaesthesiologists may be a significant source of medical errors in the operating room, and suggests that a point-of-care information system for the anaesthesiologist may be of value.

  20. Organic chemistry and biology of the interstellar medium

    NASA Technical Reports Server (NTRS)

    Sagan, C.

    1973-01-01

    Interstellar organic chemistry is discussed as the field of study emerging from the discovery of microwave lines of formaldehyde and of hydrogen cyanide in the interstellar medium. The reliability of molecular identifications and comparisons of interstellar and cometary compounds are considered, along with the degradational origin of simple organics. It is pointed out that the contribution of interstellar organic chemistry to problems in biology is not substantive but analogical. The interstellar medium reveals the operation of chemical processes which, on earth and perhaps on vast numbers of planets throughout the universe, led to the origin of life, but the actual molecules of the interstellar medium are unlikely to play any significant biological role.

  1. Advances in paper-based sample pretreatment for point-of-care testing.

    PubMed

    Tang, Rui Hua; Yang, Hui; Choi, Jane Ru; Gong, Yan; Feng, Shang Sheng; Pingguan-Murphy, Belinda; Huang, Qing Sheng; Shi, Jun Ling; Mei, Qi Bing; Xu, Feng

    2017-06-01

    In recent years, paper-based point-of-care testing (POCT) has been widely used in medical diagnostics, food safety and environmental monitoring. However, a high-cost, time-consuming and equipment-dependent sample pretreatment technique is generally required for raw sample processing, which are impractical for low-resource and disease-endemic areas. Therefore, there is an escalating demand for a cost-effective, simple and portable pretreatment technique, to be coupled with the commonly used paper-based assay (e.g. lateral flow assay) in POCT. In this review, we focus on the importance of using paper as a platform for sample pretreatment. We firstly discuss the beneficial use of paper for sample pretreatment, including sample collection and storage, separation, extraction, and concentration. We highlight the working principle and fabrication of each sample pretreatment device, the existing challenges and the future perspectives for developing paper-based sample pretreatment technique.

  2. Enhancing point of care vigilance using computers.

    PubMed

    St Jacques, Paul; Rothman, Brian

    2011-09-01

    Information technology has the potential to provide a tremendous step forward in perioperative patient safety. Through automated delivery of information through fixed and portable computer resources, clinicians may achieve improved situational awareness of the overall operation of the operating room suite and the state of individual patients in various stages of surgical care. Coupling the raw, but integrated, information with decision support and alerting algorithms enables clinicians to achieve high reliability in documentation compliance and response to care protocols. Future studies and outcomes analysis are needed to quantify the degree of benefit of these new components of perioperative information systems. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Electrochemical magnetic microbeads-based biosensor for point-of-care serodiagnosis of infectious diseases.

    PubMed

    Cortina, María E; Melli, Luciano J; Roberti, Mariano; Mass, Mijal; Longinotti, Gloria; Tropea, Salvador; Lloret, Paulina; Serantes, Diego A Rey; Salomón, Francisco; Lloret, Matías; Caillava, Ana J; Restuccia, Sabrina; Altcheh, Jaime; Buscaglia, Carlos A; Malatto, Laura; Ugalde, Juan E; Fraigi, Liliana; Moina, Carlos; Ybarra, Gabriel; Ciocchini, Andrés E; Comerci, Diego J

    2016-06-15

    Access to appropriate diagnostic tools is an essential component in the evaluation and improvement of global health. Additionally, timely detection of infectious agents is critical in early diagnosis and treatment of infectious diseases. Conventional pathogen detection methods such as culturing, enzyme linked immunosorbent assay (ELISA) or polymerase chain reaction (PCR) require long assay times, and complex and expensive instruments making them not adaptable to point-of-care (PoC) needs at resource-constrained places and primary care settings. Therefore, there is an unmet need to develop portable, simple, rapid, and accurate methods for PoC detection of infections. Here, we present the development and validation of a portable, robust and inexpensive electrochemical magnetic microbeads-based biosensor (EMBIA) platform for PoC serodiagnosis of infectious diseases caused by different types of microorganisms (parasitic protozoa, bacteria and viruses). We demonstrate the potential use of the EMBIA platform for in situ diagnosis of human (Chagas disease and human brucellosis) and animal (bovine brucellosis and foot-and-mouth disease) infections clearly differentiating infected from non-infected individuals or animals. For Chagas disease, a more extensive validation of the test was performed showing that the EMBIA platform displayed an excellent diagnostic performance almost indistinguishable, in terms of specificity and sensitivity, from a fluorescent immunomagnetic assay and the conventional ELISA using the same combination of antigens. This platform technology could potentially be applicable to diagnose other infectious and non-infectious diseases as well as detection and/or quantification of biomarkers at the POC and primary care settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Routine use of point-of-care tests: usefulness and application in clinical microbiology.

    PubMed

    Clerc, O; Greub, G

    2010-08-01

    Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

  5. Expansion Mini-Microscopy: An Enabling Alternative in Point-of-Care Diagnostics

    PubMed Central

    Zhang, Yu Shrike; Santiago, Grissel Trujillo-de; Alvarez, Mario Moisés; Schiff, Steven J.; Boyden, Edward S.; Khademhosseini, Ali

    2017-01-01

    Diagnostics play a significant role in health care. In the developing world and low-resource regions the utility for point-of-care (POC) diagnostics becomes even greater. This need has long been recognized, and diagnostic technology has seen tremendous progress with the development of portable instrumentation such as miniature imagers featuring low complexity and cost. However, such inexpensive devices have not been able to achieve a resolution sufficient for POC detection of pathogens at very small scales, such as single-cell parasites, bacteria, fungi, and viruses. To this end, expansion microscopy (ExM) is a recently developed technique that, by physically expanding preserved biological specimens through a chemical process, enables super-resolution imaging on conventional microscopes and improves imaging resolution of a given microscope without the need to modify the existing microscope hardware. Here we review recent advances in ExM and portable imagers, respectively, and discuss the rational combination of the two technologies, that we term expansion mini-microscopy (ExMM). In ExMM, the physical expansion of a biological sample followed by imaging on a mini-microscope achieves a resolution as high as that attainable by conventional high-end microscopes imaging non-expanded samples, at significant reduction in cost. We believe that this newly developed ExMM technique is likely to find widespread applications in POC diagnostics in resource-limited and remote regions by expanded-scale imaging of biological specimens that are otherwise not resolvable using low-cost imagers. PMID:29062977

  6. HIV Point-of-Care Testing in Canadian Settings: A Scoping Review.

    PubMed

    Minichiello, Alexa; Swab, Michelle; Chongo, Meck; Marshall, Zack; Gahagan, Jacqueline; Maybank, Allison; Hot, Aurélie; Schwandt, Michael; Gaudry, Sonia; Hurley, Oliver; Asghari, Shabnam

    2017-01-01

    HIV point-of-care testing (POCT) was approved for use in Canada in 2005 and provides important public health benefits by providing rapid screening results rather than sending a blood sample to a laboratory and waiting on test results. Access to test results soon after testing (or during the same visit) is believed to increase the likelihood that individuals will receive their results and improve access to confirmatory testing and linkages to care. This paper reviews the literature on the utilization of HIV POCT across Canadian provinces. We searched OVID Medline, Embase, EBM Reviews, PsycINFO, CINAHL, and 20 electronic grey literature databases. All empirical studies investigating HIV POCT programs in Canada published in French or English were included. Searches of academic databases identified a total of 6,091 records. After removing duplicates and screening for eligibility, 27 records were included. Ten studies are peer-reviewed articles, and 17 are grey literature reports. HIV POCT in Canada is both feasible and accepted by Canadians. It is preferred to conventional HIV testing (ranging from 81.1 to 97%), and users are highly satisfied with the testing process (ranging between 96 and 100%). The majority of studies demonstrate that HIV POCT is feasible, preferred, and accepted by diverse populations in Canada. Losses to follow-up and linkage rates are also good. However, more research is needed to understand how best to scale up HIV POCT in contexts that currently have very limited or no access to testing.

  7. Accuracy of Point-of-care Ultrasonography for Diagnosing Acute Appendicitis: A Systematic Review and Meta-analysis.

    PubMed

    Matthew Fields, J; Davis, Joshua; Alsup, Carl; Bates, Amanda; Au, Arthur; Adhikari, Srikar; Farrell, Isaac

    2017-09-01

    The use of ultrasonography (US) to diagnose appendicitis is well established. More recently, point-of-care ultrasonography (POCUS) has also been studied for the diagnosis of appendicitis, which may also prove a valuable diagnostic tool. The purpose of this study was through systematic review and meta-analysis to identify the test characteristics of POCUS, specifically US performed by a nonradiologist physician, in accurately diagnosing acute appendicitis in patients of any age. We conducted a thorough and systematic literature search of English language articles published on point-of-care, physician-performed transabdominal US used for the diagnosis of acute appendicitis from 1980 to May, 2015 using OVID MEDLINE In-Process & Other Non-indexed Citations and Scopus. Studies were selected and subsequently independently abstracted by two trained reviewers. A random-effects pooled analysis was used to construct a hierarchical summary receiver operator characteristic curve, and a meta-regression was performed. Quality of studies was assessed using the QUADAS-2 tool. Our search yielded 5,792 unique studies and we included 21 of these in our final review. Prevalence of disease in this study was 29.8%, (range = 6.4%-75.4%). The sensitivity and specificity for POCUS in diagnosing appendicitis were 91% (95% confidence interval [CI] = 83%-96%) and 97% (95% CI = 91%-99%), respectively. The positive and negative predictive values were 91 and 94%, respectively. Studies performed by emergency physicians had slightly lower test characteristics (sensitivity = 80%, specificity = 92%). There was significant heterogeneity between studies (I 2 = 99%, 95% CI = 99%-100%) and the quality of the reported studies was moderate, mostly due to unclear reporting of blinding of physicians and timing of scanning and patient enrollment. Several of the studies were performed by a single operator, and the education and training of the operators were variably reported. Point-of-care US has relatively

  8. Point-of-care ultrasound versus auscultation in determining the position of double-lumen tube

    PubMed Central

    Hu, Wei-Cai; Xu, Lei; Zhang, Quan; Wei, Li; Zhang, Wei

    2018-01-01

    Abstract This study was designed to assess the accuracy of point-of-care ultrasound in determining the position of double-lumen tubes (DLTs). A total of 103 patients who required DLT intubation were enrolled into the study. After DLTs were tracheal intubated in the supine position, an auscultation researcher and ultrasound researcher were sequentially invited in the operating room to conduct their evaluation of the DLT. After the end of their evaluation, fiberscope researchers (FRs) were invited in the operating room to evaluate the position of DLT using a fiberscope. After the patients were changed to the lateral position, the same evaluation process was repeated. These 3 researchers were blind to each other when they made their conclusions. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were obtained by statistical analysis. When left DLTs (LDLTs) were used, the accuracy of ultrasound (84.2% [72.1%, 92.5%]) was higher than the accuracy of auscultation (59.7% [45.8%, 72.4%]) (P < .01). When right DLTs (RDLTs) were used, the accuracy of ultrasound (89.1% [76.4%, 96.4%]) was higher than the accuracy of auscultation (67.4% [52.0%, 80.5%]) (P < .01). When LDLTs were used in the lateral position, the accuracy of ultrasound (75.4% [62.2%, 85.9%]) was higher than the accuracy of auscultation (54.4% [40.7%, 67.6%]) (P < .05). When RDLT were used, the accuracy of ultrasound (73.9% [58.9%, 85.7%]) was higher than the accuracy of auscultation (47.8% [32.9%, 63.1%]) (P < .05). Assessment via point-of-care ultrasound is superior to auscultation in determining the position of DLTs. PMID:29595696

  9. Point-of-care ultrasound versus auscultation in determining the position of double-lumen tube.

    PubMed

    Hu, Wei-Cai; Xu, Lei; Zhang, Quan; Wei, Li; Zhang, Wei

    2018-03-01

    This study was designed to assess the accuracy of point-of-care ultrasound in determining the position of double-lumen tubes (DLTs).A total of 103 patients who required DLT intubation were enrolled into the study. After DLTs were tracheal intubated in the supine position, an auscultation researcher and ultrasound researcher were sequentially invited in the operating room to conduct their evaluation of the DLT. After the end of their evaluation, fiberscope researchers (FRs) were invited in the operating room to evaluate the position of DLT using a fiberscope. After the patients were changed to the lateral position, the same evaluation process was repeated. These 3 researchers were blind to each other when they made their conclusions. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were obtained by statistical analysis.When left DLTs (LDLTs) were used, the accuracy of ultrasound (84.2% [72.1%, 92.5%]) was higher than the accuracy of auscultation (59.7% [45.8%, 72.4%]) (P < .01). When right DLTs (RDLTs) were used, the accuracy of ultrasound (89.1% [76.4%, 96.4%]) was higher than the accuracy of auscultation (67.4% [52.0%, 80.5%]) (P < .01). When LDLTs were used in the lateral position, the accuracy of ultrasound (75.4% [62.2%, 85.9%]) was higher than the accuracy of auscultation (54.4% [40.7%, 67.6%]) (P < .05). When RDLT were used, the accuracy of ultrasound (73.9% [58.9%, 85.7%]) was higher than the accuracy of auscultation (47.8% [32.9%, 63.1%]) (P < .05).Assessment via point-of-care ultrasound is superior to auscultation in determining the position of DLTs.

  10. Planning for the integration of the digital library, clinical decision support, and evidence at the point of care.

    PubMed

    Schwartz, Linda Matula; Iobst, Barbara

    2008-01-01

    Integrating knowledge-based resources at the point of care is an important opportunity for hospital library involvement. In the progression of an IAIMS planning grant, the digital library is recognized as pivotal to the success of information domain integration throughout the institution. The planning process, data collection, and evolution of the planning project are discussed.

  11. Feasibility, accuracy, and clinical effect of point-of-care Xpert MTB/RIF testing for tuberculosis in primary-care settings in Africa: a multicentre, randomised, controlled trial.

    PubMed

    Theron, Grant; Zijenah, Lynn; Chanda, Duncan; Clowes, Petra; Rachow, Andrea; Lesosky, Maia; Bara, Wilbert; Mungofa, Stanley; Pai, Madhukar; Hoelscher, Michael; Dowdy, David; Pym, Alex; Mwaba, Peter; Mason, Peter; Peter, Jonny; Dheda, Keertan

    2014-02-01

    The Xpert MTB/RIF test for tuberculosis is being rolled out in many countries, but evidence is lacking regarding its implementation outside laboratories, ability to inform same-day treatment decisions at the point of care, and clinical effect on tuberculosis-related morbidity. We aimed to assess the feasibility, accuracy, and clinical effect of point-of-care Xpert MTB/RIF testing at primary-care health-care facilities in southern Africa. In this pragmatic, randomised, parallel-group, multicentre trial, we recruited adults with symptoms suggestive of active tuberculosis from five primary-care health-care facilities in South Africa, Zimbabwe, Zambia, and Tanzania. Eligible patients were randomly assigned using pregenerated tables to nurse-performed Xpert MTB/RIF at the clinic or sputum smear microscopy. Participants with a negative test result were empirically managed according to local WHO-compliant guidelines. Our primary outcome was tuberculosis-related morbidity (measured with the TBscore and Karnofsky performance score [KPS]) in culture-positive patients who had begun anti-tuberculosis treatment, measured at 2 months and 6 months after randomisation, analysed by intention to treat. This trial is registered with Clinicaltrials.gov, number NCT01554384. Between April 12, 2011, and March 30, 2012, we randomly assigned 758 patients to smear microscopy (182 culture positive) and 744 to Xpert MTB/RIF (185 culture positive). Median TBscore in culture-positive patients did not differ between groups at 2 months (2 [IQR 0-3] in the smear microscopy group vs 2 [0·25-3] in the MTB/RIF group; p=0·85) or 6 months (1 [0-3] vs 1 [0-3]; p=0·35), nor did median KPS at 2 months (80 [70-90] vs 90 [80-90]; p=0·23) or 6 months (100 [90-100] vs 100 [90-100]; p=0·85). Point-of-care MTB/RIF had higher sensitivity than microscopy (154 [83%] of 185 vs 91 [50%] of 182; p=0·0001) but similar specificity (517 [95%] 544 vs 540 [96%] of 560; p=0·25), and had similar sensitivity to

  12. Exploration of fluorine chemistry at the multidisciplinary interface of chemistry and biology.

    PubMed

    Ojima, Iwao

    2013-07-05

    Over the last three decades, my engagement in "fluorine chemistry" has evolved substantially because of the multidisciplinary nature of the research programs. I began my research career as a synthetic chemist in organometallic chemistry and homogeneous catalysis directed toward organic synthesis. Then, I was brought into a very unique world of "fluorine chemistry" in the end of 1970s. I started exploring the interface of fluorine chemistry and transition metal homogeneous catalysis first, which was followed by amino acids, peptides, and peptidomimetics for medicinal chemistry. Since then, I have been exploring the interfaces of fluorine chemistry and multidisciplinary fields of research involving medicinal chemistry, chemical biology, cancer biology, and molecular imaging. This perspective intends to cover my fruitful endeavor in the exploration of fluorine chemistry at the multidisciplinary interface of chemistry and biology in a chronological order to show the evolution of my research interest and strategy.

  13. Equipment-free nucleic acid extraction and amplification on a simple paper disc for point-of-care diagnosis of rotavirus A.

    PubMed

    Ye, Xin; Xu, Jin; Lu, Lijuan; Li, Xinxin; Fang, Xueen; Kong, Jilie

    2018-08-14

    The use of paper-based methods for clinical diagnostics is a rapidly expanding research topic attracting a great deal of interest. Some groups have attempted to realize an integrated nucleic acid test on a single microfluidic paper chip, including extraction, amplification, and readout functions. However, these studies were not able to overcome complex modification and fabrication requirements, long turn-around times, or the need for sophisticated equipment like pumps, thermal cyclers, or centrifuges. Here, we report an extremely simple paper-based test for the point-of-care diagnosis of rotavirus A, one of the most common pathogens that causes pediatric gastroenteritis. This paper-based test could perform nucleic acid extraction within 5 min, then took 25 min to amplify the target sequence, and the result was visible to the naked eye immediately afterward or quantitative by the UV-Vis absorbance. This low-cost method does not require extra equipment and is easy to use either in a lab or at the point-of-care. The detection limit for rotavirus A was found to be 1 × 10 3 copies/mL. In addition, 100% sensitivity and specificity were achieved when testing 48 clinical stool samples. In conclusion, the present paper-based test fulfills the main requirements for a point-of-care diagnostic tool, and has the potential to be applied to disease prevention, control, and precision diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. A concept for a visual computer interface to make error taxonomies useful at the point of primary care.

    PubMed

    Singh, Ranjit; Pace, Wilson; Singh, Sonjoy; Singh, Ashok; Singh, Gurdev

    2007-01-01

    Evidence suggests that the quality of care delivered by the healthcare industry currently falls far short of its capabilities. Whilst most patient safety and quality improvement work to date has focused on inpatient settings, some estimates suggest that outpatient settings are equally important, with up to 200,000 avoidable deaths annually in the United States of America (USA) alone. There is currently a need for improved error reporting and taxonomy systems that are useful at the point of care. This provides an opportunity to harness the benefits of computer visualisation to help structure and illustrate the 'stories' behind errors. In this paper we present a concept for a visual taxonomy of errors, based on visual models of the healthcare system at both macrosystem and microsystem levels (previously published in this journal), and describe how this could be used to create a visual database of errors. In an alphatest in a US context, we were able to code a sample of 20 errors from an existing error database using the visual taxonomy. The approach is designed to capture and disseminate patient safety information in an unambiguous format that is useful to all members of the healthcare team (including the patient) at the point of care as well as at the policy-making level.

  15. Development of a magnetic lab-on-a-chip for point-of-care sepsis diagnosis

    NASA Astrophysics Data System (ADS)

    Schotter, Joerg; Shoshi, Astrit; Brueckl, Hubert

    2009-05-01

    We present design criteria, operation principles and experimental examples of magnetic marker manipulation for our magnetic lab-on-a-chip prototype. It incorporates both magnetic sample preparation and detection by embedded GMR-type magnetoresistive sensors and is optimized for the automated point-of-care detection of four different sepsis-indicative cytokines directly from about 5 μl of whole blood. The sample volume, magnetic particle size and cytokine concentration determine the microfluidic volume, sensor size and dimensioning of the magnetic gradient field generators. By optimizing these parameters to the specific diagnostic task, best performance is expected with respect to sensitivity, analysis time and reproducibility.

  16. Simple Approaches to Minimally-Instrumented, Microfluidic-Based Point-of-Care Nucleic Acid Amplification Tests

    PubMed Central

    Mauk, Michael G.; Song, Jinzhao; Liu, Changchun; Bau, Haim H.

    2018-01-01

    Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs) in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC) tests for resource-limited settings. Microfluidic cartridges (‘chips’) that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets) is demonstrated. Low-cost detection and added functionality (data analysis, control, communication) can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed. PMID:29495424

  17. Recombinant human G6PD for quality control and quality assurance of novel point-of-care diagnostics for G6PD deficiency.

    PubMed

    Kahn, Maria; LaRue, Nicole; Zhu, Changcheng; Pal, Sampa; Mo, Jack S; Barrett, Lynn K; Hewitt, Steve N; Dumais, Mitchell; Hemmington, Sandra; Walker, Adrian; Joynson, Jeff; Leader, Brandon T; Van Voorhis, Wesley C; Domingo, Gonzalo J

    2017-01-01

    A large gap for the support of point-of-care testing is the availability of reagents to support quality control (QC) of diagnostic assays along the supply chain from the manufacturer to the end user. While reagents and systems exist to support QC of laboratory screening tests for glucose-6-phosphate dehydrogenase (G6PD) deficiency, they are not configured appropriately to support point-of-care testing. The feasibility of using lyophilized recombinant human G6PD as a QC reagent in novel point-of-care tests for G6PD deficiency is demonstrated. Human recombinant G6PD (r-G6PD) was expressed in Escherichia coli and purified. Aliquots were stored at -80°C. Prior to lyophilization, aliquots were thawed, and three concentrations of r-G6PD (representing normal, intermediate, and deficient clinical G6PD levels) were prepared and mixed with a protective formulation, which protects the enzyme activity against degradation from denaturation during the lyophilization process. Following lyophilization, individual single-use tubes of lyophilized r-G6PD were placed in individual packs with desiccants and stored at five temperatures for one year. An enzyme assay for G6PD activity was used to ascertain the stability of r-G6PD activity while stored at different temperatures. Lyophilized r-G6PD is stable and can be used as a control indicator. Results presented here show that G6PD activity is stable for at least 365 days when stored at -80°C, 4°C, 30°C, and 45°C. When stored at 55°C, enzyme activity was found to be stable only through day 28. Lyophilized r-G6PD enzyme is stable and can be used as a control for point-of-care tests for G6PD deficiency.

  18. Comparative effectiveness research in DARTNet primary care practices: point of care data collection on hypoglycemia and over-the-counter and herbal use among patients diagnosed with diabetes.

    PubMed

    Libby, Anne M; Pace, Wilson; Bryan, Cathy; Anderson, Heather Orton; Ellis, Samuel L; Allen, Richard Read; Brandt, Elias; Huebschmann, Amy G; West, David; Valuck, Robert J

    2010-06-01

    The Distributed Ambulatory Research in Therapeutics Network (DARTNet) is a federated network of electronic health record (EHR) data, designed as a platform for next-generation comparative effectiveness research in real-world settings. DARTNet links information from nonintegrated primary care clinics that use EHRs to deliver ambulatory care to overcome limitations with traditional observational research. Test the ability to conduct a remote, electronic point of care study in DARTNet practices by prompting clinic staff to obtain specific information during a patient encounter. Prospective survey of patients identified through queries of clinical data repositories in federated network organizations. On patient visit, survey is triggered and data are relinked to the EHR, de-identified, and copied for evaluation. Adult patients diagnosed with diabetes mellitus that scheduled a clinic visit for any reason in a 2-week period in DARTNet primary care practices. Survey on hypoglycemic events (past month) and over-the-counter and herbal supplement use. DARTNet facilitated point of care data collection triggered by an electronic prompt for additional information at a patient visit. More than one-third of respondents (33% response rate) reported either mild (45%) or severe hypoglycemic events (5%) in the month before the survey; only 3 of those were also coded using the ICD-9 (a significant difference in detection rates 37% vs. 1%). Nearly one-quarter of patients reported taking an OTC/herbal, 4% specifically for the treatment of symptoms of diabetes. Prospective data collection is feasible in DARTNet and can enable comparative effectiveness and safety research.

  19. Patient-Centered Care: Depends on the Point of View

    ERIC Educational Resources Information Center

    Lorig, Kate

    2012-01-01

    Patient-centered care is now front-and-center in health care reform. The federal government has established the Patient-Centered Outcomes Research Institute to study this new phenomenon and health care delivery systems such as patient-centered medical homes. Where is the health education profession in all of this? Despite what it has to offer, to…

  20. Miniaturized technology for protein and nucleic acid point-of-care testing.

    PubMed

    Olasagasti, Felix; Ruiz de Gordoa, Juan Carlos

    2012-11-01

    The field of point-of-care (POC) testing technology is developing quickly and producing instruments that are increasingly reliable, while their size is being gradually reduced. Proteins are a common target for POC analyses and the detection of protein markers typically involves immunoassays aimed at detecting different groups of proteins such as tumor markers, inflammation proteins, and cardiac markers; but other techniques can also be used to analyze plasma proteins. In the case of nucleic acids, hybridization and amplification strategies can be used to record electromagnetic or electric signals. These techniques allow for the identification of specific viral or bacterial infections as well as specific cancers. In this review, we consider some of the latest advances in the analysis of specific nucleic acid and protein biomarkers, taking into account their trend toward miniaturization and paying special attention to the technology that can be implemented in future applications, such as lab-on-a-chip instruments. Copyright © 2012 Mosby, Inc. All rights reserved.

  1. Simultaneous point-of-care detection of anemia and sickle cell disease in Tanzania: the RAPID study.

    PubMed

    Smart, Luke R; Ambrose, Emmanuela E; Raphael, Kevin C; Hokororo, Adolfine; Kamugisha, Erasmus; Tyburski, Erika A; Lam, Wilbur A; Ware, Russell E; McGann, Patrick T

    2018-02-01

    Both anemia and sickle cell disease (SCD) are highly prevalent across sub-Saharan Africa, and limited resources exist to diagnose these conditions quickly and accurately. The development of simple, inexpensive, and accurate point-of-care (POC) assays represents an important advance for global hematology, one that could facilitate timely and life-saving medical interventions. In this prospective study, Robust Assays for Point-of-care Identification of Disease (RAPID), we simultaneously evaluated a POC immunoassay (Sickle SCAN™) to diagnose SCD and a first-generation POC color-based assay to detect anemia. Performed at Bugando Medical Center in Mwanza, Tanzania, RAPID tested 752 participants (age 1 day to 20 years) in four busy clinical locations. With minimally trained medical staff, the SCD POC assay diagnosed SCD with 98.1% sensitivity and 91.1% specificity. The hemoglobin POC assay had 83.2% sensitivity and 74.5% specificity for detection of severe anemia (Hb ≤ 7 g/dL). Interobserver agreement was excellent for both POC assays (r = 0.95-0.96). Results for the hemoglobin POC assay have informed the second-generation assay design to be more suitable for low-resource settings. RAPID provides practical feasibility data regarding two novel POC assays for the diagnosis of anemia and SCD in real-world field evaluations and documents the utility and potential impact of these POC assays for sub-Saharan Africa.

  2. Distance-based microfluidic quantitative detection methods for point-of-care testing.

    PubMed

    Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James

    2016-04-07

    Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.

  3. Comparison of a gel column blood typing method and a point-of-care cartridge for dog erythrocyte antigen 1.1.

    PubMed

    Blois, Shauna L; Richardson, Danielle M; Abrams-Ogg, Anthony C G

    2013-01-01

    Blood typing for the presence of Dog Erythrocyte Antigen (DEA) 1.1 is recommended in all donor and recipient dogs prior to transfusion of blood products. The objective of this study was to determine if a point-of-care DEA 1.1 blood typing cartridge could be used in place of the gel column typing method. Detection of DEA 1.1 was performed using a laboratory-based gel column method and a point-of-care cartridge. A convenience sample of 30 healthy blood donors, 13 dogs with immune-mediated hemolytic anemia (IMHA) (3 of which had concurrent immune-mediated thrombocytopenia [IMT]), and 44 dogs with other diseases was included in the study. Agreement was observed between the tests for normal dogs and dogs with nonimmune-mediated disease in 74/74 cases. Two dogs in the IMHA group had indeterminate gel column blood typing results; 1 dog in this group had a negative gel column test result but a positive cartridge test result. There was good agreement between the 2 methods for normal dogs and dogs with nonimmune-mediated disease. Blood typing methods in dogs with IMHA should be further investigated. © Veterinary Emergency and Critical Care Society 2013.

  4. Microfluidics for High School Chemistry Students.

    PubMed

    Hemling, Melissa; Crooks, John A; Oliver, Piercen M; Brenner, Katie; Gilbertson, Jennifer; Lisensky, George C; Weibel, Douglas B

    2014-01-14

    We present a laboratory experiment that introduces high school chemistry students to microfluidics while teaching fundamental properties of acid-base chemistry. The procedure enables students to create microfluidic systems using nonspecialized equipment that is available in high school classrooms and reagents that are safe, inexpensive, and commercially available. The experiment is designed to ignite creativity and confidence about experimental design in a high school chemistry class. This experiment requires a computer program (e.g., PowerPoint), Shrinky Dink film, a readily available silicone polymer, weak acids, bases, and a colorimetric pH indicator. Over the span of five 45-min class periods, teams of students design and prepare devices in which two different pH solutions mix in a predictable way to create five different pH solutions. Initial device designs are instructive but rarely optimal. During two additional half-class periods, students have the opportunity to use their initial observations to redesign their microfluidic systems to optimize the outcome. The experiment exposes students to cutting-edge science and the design process, and solidifies introductory chemistry concepts including laminar flow, neutralization of weak acids-bases, and polymers.

  5. Microfluidics for High School Chemistry Students

    PubMed Central

    Hemling, Melissa; Crooks, John A.; Oliver, Piercen M.; Brenner, Katie; Gilbertson, Jennifer; Lisensky, George C.; Weibel, Douglas B.

    2014-01-01

    We present a laboratory experiment that introduces high school chemistry students to microfluidics while teaching fundamental properties of acid–base chemistry. The procedure enables students to create microfluidic systems using nonspecialized equipment that is available in high school classrooms and reagents that are safe, inexpensive, and commercially available. The experiment is designed to ignite creativity and confidence about experimental design in a high school chemistry class. This experiment requires a computer program (e.g., PowerPoint), Shrinky Dink film, a readily available silicone polymer, weak acids, bases, and a colorimetric pH indicator. Over the span of five 45-min class periods, teams of students design and prepare devices in which two different pH solutions mix in a predictable way to create five different pH solutions. Initial device designs are instructive but rarely optimal. During two additional half-class periods, students have the opportunity to use their initial observations to redesign their microfluidic systems to optimize the outcome. The experiment exposes students to cutting-edge science and the design process, and solidifies introductory chemistry concepts including laminar flow, neutralization of weak acids–bases, and polymers. PMID:25584013

  6. What Chemists (or Chemistry Students) Need to Know about Computing.

    ERIC Educational Resources Information Center

    Swift, Mary L.; Zielinski, Theresa Julia

    1995-01-01

    Presents key points of an on-line conference discussion and integrates them with information from the literature. Key points included: computer as a tool for learning, study, research, and communication; hardware, software, computing concepts, and other teaching concerns; and the appropriate place for chemistry computer-usage instruction. (45…

  7. Hemoglobin A1c Point-of-Care Assays; a New World with a Lot of Consequences!

    PubMed Central

    Lenters-Westra, Erna; Slingerland, Robbert J.

    2009-01-01

    Background Point-of-care instruments for the measurement of hemoglobin A1c (HbA1c) may improve the glycemic control of people with diabetes by providing a rapid result if the performance of the instruments used is acceptable. A 0.5% HbA1c difference between successive results is considered a clinically relevant change. With this in mind, the In2it from Bio-Rad and the DCA Vantage from Siemens were evaluated according to Clinical and Laboratory Standards Institute (CLSI) protocols. Methods The CLSI protocols EP-5 and EP-9 were applied to investigate precision, accuracy, and bias. The bias was compared with three certified secondary reference measurement procedures. Differences between capillary and venous blood were investigated by an end-user group consisting of nurse practitioners at a diabetes care center. Results At HbA1c levels of 5.1 and 11.2%, total coefficients of variation (CV) for the In2it were 4.9 and 3.3%, respectively, and for the DCA Vantage were 1.7 to 1.8% and 3.7 to 5.5% depending on the lot number of the cartridges. Method comparisons showed significant lot number-dependent results for the In2it and the DCA Vantage compared with the three reference methods. No overall difference was observed between capillary and venous blood for both methods. Conclusion Performance results of the In2it and the DCA Vantage showed variable and lot number-dependent results. To maintain the interlaboratory CV of 5% for HbA1c, the Clinical Laboratory Improvement Amendments rules for waived point-of-care instruments should be revised. An obligation for participating in external quality schemes and taking adequate action should be considered for POC instruments that perform poorly. PMID:20144277

  8. Economic evaluation of point-of-care testing in the remote primary health care setting of Australia's Northern Territory.

    PubMed

    Spaeth, Brooke A; Kaambwa, Billingsley; Shephard, Mark Ds; Omond, Rodney

    2018-01-01

    To determine the cost-effectiveness of utilizing point-of-care testing (POCT) on the Abbott i-STAT device as a support tool to aid decisions regarding the emergency medical retrievals of patients at remote health centers in the Northern Territory (NT) of Australia. A decision analytic simulation model-based economic evaluation was conducted using data from patients presenting with three common acute conditions (chest pain, chronic renal failure due to missed dialysis session(s), and acute diarrhea) at six remote NT health centers from July to December 2015. The specific outcomes measured in this study were the number of unnecessary emergency medical retrieval prevented through POCT. Cost savings through prevented unnecessary medical retrievals for each presentation type were then determined and extrapolated to give per annum NT-wide estimates. POCT prevented 60 unnecessary medical evacuations from a total of 200 patient cases meeting the selection criteria (48/147 for chest pain, 10/28 for missed dialysis, and 2/25 for acute diarrhea). The associated cost savings were AUD $4,674, $8,034, and $786 per patient translating to NT-wide savings of AUD $13.72 million, $6.45 million, and $1.57 million per annum (AUD $21.75 million in total) for chest pain, missed dialysis, and acute diarrhea presentations, respectively. This study demonstrated that POCT when used to aid decision making for acutely ill patients delivered significant cost savings for the NT health care system by preventing unnecessary emergency medical retrievals.

  9. [Regulation of sexual expression in residential aged care facilities: A professional point of view].

    PubMed

    Villar, Feliciano; Fabà, Josep; Celdrán, Montserrat; Serrat, Rodrigo

    2014-01-01

    The purpose of this study is to determine the opinion of professionals working in residential aged care facilities on the regulation of sexuality in these settings. Fifty-three professionals from five residential aged care facilities located in the metropolitan area of Barcelona answered several questions regarding the advisability of establishing measures for the regulation of sexuality in RACFs, the elements that could contribute to this, and the aspects that such regulations should consider. Around 50% of the participants recognized the advisability of having some type of measures for sexuality regulation in residential aged care facilities. According to their responses this should be developed taking into account professional opinions, but also the points of view of the residents and their relatives. The most frequently mentioned regulations were those that ensured that any kind of sexually charged situation occurred in a private environment. The development of strategies are suggested to distinguish those people with dementia that are competent to consent to sexual acts from those who are not. The opinion of professionals working in RACFs regarding the advisability of establishing measures for sexuality regulation seems to be considerably divided. Thus, whilst around 50% of them recognize their potential usefulness, the other half consider them unnecessary or even counterproductive for the sexual freedom of residents. Associating regulation with prohibition and sexuality with sexual activity was not uncommon among the responses of the participants. Copyright © 2014 SEGG. Published by Elsevier Espana. All rights reserved.

  10. Quality assuring HIV point of care testing using whole blood samples.

    PubMed

    Dare-Smith, Raellene; Badrick, Tony; Cunningham, Philip; Kesson, Alison; Badman, Susan

    2016-08-01

    The Royal College of Pathologists Australasia Quality Assurance Programs (RCPAQAP), have offered dedicated external quality assurance (EQA) for HIV point of care testing (PoCT) since 2011. Prior to this, EQA for these tests was available within the comprehensive human immunodeficiency virus (HIV) module. EQA testing for HIV has typically involved the supply of serum or plasma, while in the clinic or community based settings HIV PoCT is generally performed using whole blood obtained by capillary finger-stick collection. RCPAQAP has offered EQA for HIV PoCT using stabilised whole blood since 2014. A total of eight surveys have been undertaken over a period of 2 years from 2014 to 2015. Of the 962 responses received, the overall consensus rate was found to be 98% (941/962). A total of 21 errors were detected. The majority of errors were attributable to false reactive HIV p24 antigen results (9/21, 43%), followed by false reactive HIV antibody results (8/21, 38%). There were 4/21 (19%) false negative HIV antibody results and no false negative HIV p24 antigen results reported. Overall performance was observed to vary minimally between surveys, from a low of 94% up to 99% concordant. Encouraging levels of testing proficiency for HIV PoCT are indicated by these data, but they also confirm the need for HIV PoCT sites to participate in external quality assurance programs to ensure the ongoing provision of high quality patient care. Copyright © 2016 Royal College of Pathologists of Australasia. All rights reserved.

  11. Impact of point-of-care implementation of Xpert® MTB/RIF: product vs. process innovation.

    PubMed

    Schumacher, S G; Thangakunam, B; Denkinger, C M; Oliver, A A; Shakti, K B; Qin, Z Z; Michael, J S; Luo, R; Pai, M; Christopher, D J

    2015-09-01

    Both product innovation (e.g., more sensitive tests) and process innovation (e.g., a point-of-care [POC] testing programme) could improve patient outcomes. To study the respective contributions of product and process innovation in improving patient outcomes. We implemented a POC programme using Xpert(®) MTB/RIF in an out-patient clinic of a tertiary care hospital in India. We measured the impact of process innovation by comparing time to diagnosis with routine testing vs. POC testing. We measured the impact of product innovation by comparing accuracy and time to diagnosis using smear microscopy vs. POC Xpert. We enrolled 1012 patients over a 15-month period. Xpert had high accuracy, but the incremental value of one Xpert over two smears was only 6% (95%CI 3-12). Implementing Xpert as a routine laboratory test did not reduce the time to diagnosis compared to smear-based diagnosis. In contrast, the POC programme reduced the time to diagnosis by 5.5 days (95%CI 4.3-6.7), but required dedicated staff and substantial adaptation of clinic workflow. Process innovation by way of a POC Xpert programme had a greater impact on time to diagnosis than the product per se, and can yield important improvements in patient care that are complementary to those achieved by introducing innovative technologies.

  12. Spatially controlled immobilisation of biomolecules: A complete approach in green chemistry

    NASA Astrophysics Data System (ADS)

    Grinenval, Eva; Nonglaton, Guillaume; Vinet, Françoise

    2014-01-01

    The development of 'green' sensors is a challenging task in the field of biomolecule sensing, for example in the detection of cardiac troponin-I (cTnI). In the present work a complete approach in green chemistry was developed to create chemically active patterns for the immobilisation of biological probes. This key technology is discussed on the basis of the twelve green chemistry principles, and is a combination of surface patterning by spotting and surface chemistries modified by molecular vapour deposition. The (1H,1H,2H,2H)-perfluorodecyltrichlorosilane (FDTS) was used as a novel anti-adsorption layer while the 3,4-epoxybutyltrimethoxysilane (EBTMOS) was used to immobilise probes. Oligonucleotides and the anti-cTnI antibody were studied. The spatially controlled immobilisation of probes was characterised by fluorescence. The demonstrated surface modification has broad applications in areas such as diagnostics and bio-chemical sensing. Moreover, the environmental impacts of surface patterning and surface chemistry were discussed from a 'greenness' point of view.

  13. Creating a mobile subject guide to improve access to point-of-care resources for medical students: a case study.

    PubMed

    Boruff, Jill T; Bilodeau, Edward

    2012-01-01

    Can a mobile optimized subject guide facilitate medical student access to mobile point-of-care tools? The guide was created at a library at a research-intensive university with six teaching hospital sites. The team created a guide facilitating medical student access to point-of-care tools directly on mobile devices to provide information allowing them to access and set up resources with little assistance. Two librarians designed a mobile optimized subject guide for medicine and conducted a survey to test its usefulness. Web analytics and survey results demonstrate that the guide is used and the students are satisfied. The library will continue to use the subject guide as its primary means of supporting mobile devices. It remains to be seen if the mobile guide facilitates access for those who do not need assistance and want direct access to the resources. Internet access in the hospitals remains an issue.

  14. Students' Understanding of Boiling Points and Intermolecular Forces

    ERIC Educational Resources Information Center

    Schmidt, Hans-Jurgen; Kaufmann, Birgit; Treagust, David F.

    2009-01-01

    In introductory chemistry courses students are presented with the model that matter is composed of particles, and that weak forces of attraction exist between them. This model is used to interpret phenomena such as solubility and melting points, and aids in understanding the changes in states of matter as opposed to chemical reactions. We…

  15. Point-of-Care Ultrasound Assessment of Tropical Infectious Diseases--A Review of Applications and Perspectives.

    PubMed

    Bélard, Sabine; Tamarozzi, Francesca; Bustinduy, Amaya L; Wallrauch, Claudia; Grobusch, Martin P; Kuhn, Walter; Brunetti, Enrico; Joekes, Elizabeth; Heller, Tom

    2016-01-01

    The development of good quality and affordable ultrasound machines has led to the establishment and implementation of numerous point-of-care ultrasound (POCUS) protocols in various medical disciplines. POCUS for major infectious diseases endemic in tropical regions has received less attention, despite its likely even more pronounced benefit for populations with limited access to imaging infrastructure. Focused assessment with sonography for HIV-associated TB (FASH) and echinococcosis (FASE) are the only two POCUS protocols for tropical infectious diseases, which have been formally investigated and which have been implemented in routine patient care today. This review collates the available evidence for FASH and FASE, and discusses sonographic experiences reported for urinary and intestinal schistosomiasis, lymphatic filariasis, viral hemorrhagic fevers, amebic liver abscess, and visceral leishmaniasis. Potential POCUS protocols are suggested and technical as well as training aspects in the context of resource-limited settings are reviewed. Using the focused approach for tropical infectious diseases will make ultrasound diagnosis available to patients who would otherwise have very limited or no access to medical imaging. © The American Society of Tropical Medicine and Hygiene.

  16. Point-of-Care Ultrasound Assessment of Tropical Infectious Diseases—A Review of Applications and Perspectives

    PubMed Central

    Bélard, Sabine; Tamarozzi, Francesca; Bustinduy, Amaya L.; Wallrauch, Claudia; Grobusch, Martin P.; Kuhn, Walter; Brunetti, Enrico; Joekes, Elizabeth; Heller, Tom

    2016-01-01

    The development of good quality and affordable ultrasound machines has led to the establishment and implementation of numerous point-of-care ultrasound (POCUS) protocols in various medical disciplines. POCUS for major infectious diseases endemic in tropical regions has received less attention, despite its likely even more pronounced benefit for populations with limited access to imaging infrastructure. Focused assessment with sonography for HIV-associated TB (FASH) and echinococcosis (FASE) are the only two POCUS protocols for tropical infectious diseases, which have been formally investigated and which have been implemented in routine patient care today. This review collates the available evidence for FASH and FASE, and discusses sonographic experiences reported for urinary and intestinal schistosomiasis, lymphatic filariasis, viral hemorrhagic fevers, amebic liver abscess, and visceral leishmaniasis. Potential POCUS protocols are suggested and technical as well as training aspects in the context of resource-limited settings are reviewed. Using the focused approach for tropical infectious diseases will make ultrasound diagnosis available to patients who would otherwise have very limited or no access to medical imaging. PMID:26416111

  17. Designing and Implementing a Constructivist Chemistry Laboratory Program.

    ERIC Educational Resources Information Center

    Blakely, Alan

    2000-01-01

    Describes a constructivist chemistry laboratory approach based on students' personal experiences where students had the opportunity to develop their own experimental processes. Points out both the fruitfulness and difficulties of using a graduate student as a teaching assistant. (YDS)

  18. Point-of-Care Detection Devices for Food Safety Monitoring: Proactive Disease Prevention.

    PubMed

    Wu, Marie Yung-Chen; Hsu, Min-Yen; Chen, Shih-Jen; Hwang, De-Kuang; Yen, Tzung-Hai; Cheng, Chao-Min

    2017-04-01

    Food safety has become an increasingly significant public concern in both developed and under-developed nations around the world; it increases morbidity, mortality, human suffering, and economic burden. This Opinion focuses on (i) examining the influence of pathogens and chemicals (e.g., food additives and pesticide residue) on food-borne illnesses, (ii) summarizing food hazards that are present in Asia, and (iii) summarizing the array of current point-of-care (POC) detection devices that have potential applications in food safety monitoring. In addition, we provide insight into global healthcare issues in both developing and under-developed nations with a focus on bridging the gap between food safety issues in the public sector (associated with relevant clinical cases) and the use of POC detection devices for food safety monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. A study to assess the influence of interprofessional point of care simulation training on safety culture in the operating theatre environment of a university teaching hospital.

    PubMed

    Hinde, Theresa; Gale, Thomas; Anderson, Ian; Roberts, Martin; Sice, Paul

    2016-01-01

    Interprofessional point of care or in situ simulation is used as a training tool in our operating theatre directorate with the aim of improving crisis behaviours. This study aimed to assess the impact of interprofessional point of care simulation on the safety culture of operating theatres. A validated Safety Attitude Questionnaire was administered to staff members before each simulation scenario and then re-administered to the same staff members after 6-12 months. Pre- and post-training Safety Attitude Questionnaire-Operating Room (SAQ-OR) scores were compared using paired sample t-tests. Analysis revealed a statistically significant perceived improvement in both safety (p < 0.001) and teamwork (p = 0.013) climate scores (components of safety culture) 6-12 months after interprofessional simulation training. A growing body of literature suggests that a positive safety culture is associated with improved patient outcomes. Our study supports the implementation of point of care simulation as a useful intervention to improve safety culture in theatres.

  20. Point-of-care, portable microfluidic blood analyzer system

    NASA Astrophysics Data System (ADS)

    Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.

    2012-03-01

    Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.

  1. The Right Chemistry. Lawn Care Project Brings Science down to Earth.

    ERIC Educational Resources Information Center

    Dollar, David

    1992-01-01

    At Southwest High School in Fort Worth, Texas, an applied learning project enables chemistry students to determine the most effective, economical, and environmentally safe fertilizer for the lawns of schools in the district. (SK)

  2. Harmonization activities of Noklus - a quality improvement organization for point-of-care laboratory examinations.

    PubMed

    Stavelin, Anne; Sandberg, Sverre

    2018-05-16

    Noklus is a non-profit quality improvement organization that focuses to improve all elements in the total testing process. The aim is to ensure that all medical laboratory examinations are ordered, performed and interpreted correctly and in accordance with the patients' needs for investigation, treatment and follow-up. For 25 years, Noklus has focused on point-of-care (POC) testing in primary healthcare laboratories and has more than 3100 voluntary participants. The Noklus quality system uses different tools to obtain harmonization and improvement: (1) external quality assessment for the pre-examination, examination and postexamination phase to monitor the harmonization process and to identify areas that need improvement and harmonization, (2) manufacturer-independent evaluations of the analytical quality and user-friendliness of POC instruments and (3) close interactions and follow-up of the participants through site visits, courses, training and guidance. Noklus also recommends which tests that should be performed in the different facilities like general practitioner offices, nursing homes, home care, etc. About 400 courses with more than 6000 delegates are organized annually. In 2017, more than 21,000 e-learning programs were completed.

  3. The SmartBioPhone, a point of care vision under development through two European projects: OPTOLABCARD and LABONFOIL.

    PubMed

    Ruano-López, Jesus M; Agirregabiria, Maria; Olabarria, Garbiñe; Verdoy, Dolores; Bang, Dang D; Bu, Minqiang; Wolff, Anders; Voigt, Anja; Dziuban, Jan A; Walczak, Rafał; Berganzo, Javier

    2009-06-07

    This paper describes how sixteen partners from eight different countries across Europe are working together in two EU projects focused on the development of a point of care system. This system uses disposable Lab on a Chips (LOCs) that carry out the complete assay from sample preparation to result interpretation of raw samples. The LOC is either embedded in a flexible motherboard with the form of a smartcard (Labcard) or in a Skinpatch. The first project, OPTOLABCARD, extended and tested the use of a thick photoresit (SU-8) as a structural material to manufacture LOCs by lamination. This project produced several examples where SU-8 microfluidic circuitry revealed itself as a viable material for several applications, such as the integration on chip of a Polymerase Chain Reaction (PCR) that includes sample concentration, PCR amplification and optical detection of Salmonella spp. using clinical samples. The ongoing project, LABONFOIL, is using two results of OPTOLABCARD: the sample concentration method and the capability to fabricate flexible and ultra thin LOCs based on sheets instead of wafers. This rupture from the limited and expensive wafer surface heritage allows the development of a platform where LOCs are big enough to include all the sample preparation subcomponents at a low price. These LOCs will be used in four point of care applications: environment, food, cancer and drug monitoring. The user will obtain the results of the tests by connecting the Labcard/Skinpatch reader to a very popular interface (a smartphone), creating a new instrument namely "The SmartBioPhone". All standard smartphone capabilities will be at the disposal of the point of care instrument by a simple click. In order to guarantee the future mass production of these LOCs, the project will develop a large dry film equipment where LOCs will be fabricated at a low cost.

  4. Automating quantum dot barcode assays using microfluidics and magnetism for the development of a point-of-care device.

    PubMed

    Gao, Yali; Lam, Albert W Y; Chan, Warren C W

    2013-04-24

    The impact of detecting multiple infectious diseases simultaneously at point-of-care with good sensitivity, specificity, and reproducibility would be enormous for containing the spread of diseases in both resource-limited and rich countries. Many barcoding technologies have been introduced for addressing this need as barcodes can be applied to detecting thousands of genetic and protein biomarkers simultaneously. However, the assay process is not automated and is tedious and requires skilled technicians. Barcoding technology is currently limited to use in resource-rich settings. Here we used magnetism and microfluidics technology to automate the multiple steps in a quantum dot barcode assay. The quantum dot-barcoded microbeads are sequentially (a) introduced into the chip, (b) magnetically moved to a stream containing target molecules, (c) moved back to the original stream containing secondary probes, (d) washed, and (e) finally aligned for detection. The assay requires 20 min, has a limit of detection of 1.2 nM, and can detect genetic targets for HIV, hepatitis B, and syphilis. This study provides a simple strategy to automate the entire barcode assay process and moves barcoding technologies one step closer to point-of-care applications.

  5. Smartphone-Based Accurate Analysis of Retinal Vasculature towards Point-of-Care Diagnostics

    PubMed Central

    Xu, Xiayu; Ding, Wenxiang; Wang, Xuemin; Cao, Ruofan; Zhang, Maiye; Lv, Peilin; Xu, Feng

    2016-01-01

    Retinal vasculature analysis is important for the early diagnostics of various eye and systemic diseases, making it a potentially useful biomarker, especially for resource-limited regions and countries. Here we developed a smartphone-based retinal image analysis system for point-of-care diagnostics that is able to load a fundus image, segment retinal vessels, analyze individual vessel width, and store or uplink results. The proposed system was not only evaluated on widely used public databases and compared with the state-of-the-art methods, but also validated on clinical images directly acquired with a smartphone. An Android app is also developed to facilitate on-site application of the proposed methods. Both visual assessment and quantitative assessment showed that the proposed methods achieved comparable results to the state-of-the-art methods that require high-standard workstations. The proposed system holds great potential for the early diagnostics of various diseases, such as diabetic retinopathy, for resource-limited regions and countries. PMID:27698369

  6. The Eighth Central European Conference “Chemistry towards Biology”: Snapshot†

    PubMed Central

    Perczel, András; Atanasov, Atanas G.; Sklenář, Vladimír; Nováček, Jiří; Papoušková, Veronika; Kadeřávek, Pavel; Žídek, Lukáš; Kozłowski, Henryk; Watły, Joanna; Hecel, Aleksandra; Kołkowska, Paulina; Koča, Jaroslav; Svobodová-Vařeková, Radka; Pravda, Lukáš; Sehnal, David; Horský, Vladimír; Geidl, Stanislav; Enriz, Ricardo D.; Matějka, Pavel; Jeništová, Adéla; Dendisová, Marcela; Kokaislová, Alžběta; Weissig, Volkmar; Olsen, Mark; Coffey, Aidan; Ajuebor, Jude; Keary, Ruth; Sanz-Gaitero, Marta; van Raaij, Mark J.; McAuliffe, Olivia; Waltenberger, Birgit; Mocan, Andrei; Šmejkal, Karel; Heiss, Elke H.; Diederich, Marc; Musioł, Robert; Košmrlj, Janez; Polanński, Jarosław; Jampílek, Josef

    2017-01-01

    The Eighth Central European Conference “Chemistry towards Biology” was held in Brno, Czech Republic, on 28 August–1 September 2016 to bring together experts in biology, chemistry and design of bioactive compounds; promote the exchange of scientific results, methods and ideas; and encourage cooperation between researchers from all over the world. The topics of the conference covered “Chemistry towards Biology”, meaning that the event welcomed chemists working on biology-related problems, biologists using chemical methods, and students and other researchers of the respective areas that fall within the common scope of chemistry and biology. The authors of this manuscript are plenary speakers and other participants of the symposium and members of their research teams. The following summary highlights the major points/topics of the meeting. PMID:27763518

  7. User Interface Considerations for Collecting Data at the Point of Care in the Tablet PC Computing Environment

    PubMed Central

    Silvey, Garry M.; Lobach, David F.; Macri, Jennifer M.; Hunt, Megan; Kacmaz, Roje O.; Lee, Paul P.

    2006-01-01

    Collecting clinical data directly from clinicians is a challenge. Many standard development environments designed to expedite the creation of user interfaces for electronic healthcare applications do not provide acceptable components for satisfying the requirements for collecting and displaying clinical data at the point of care on the tablet computer. Through an iterative design and testing approach using think-aloud sessions in the eye care setting, we were able to identify and resolve several user interface issues. Issues that we discovered and subsequently resolved included checkboxes that were too small to be selectable with a stylus, radio buttons that could not be unselected, and font sizes that were too small to be read at arm’s length. PMID:17238715

  8. A systematic review of near real-time and point-of-care clinical decision support in anesthesia information management systems.

    PubMed

    Simpao, Allan F; Tan, Jonathan M; Lingappan, Arul M; Gálvez, Jorge A; Morgan, Sherry E; Krall, Michael A

    2017-10-01

    Anesthesia information management systems (AIMS) are sophisticated hardware and software technology solutions that can provide electronic feedback to anesthesia providers. This feedback can be tailored to provide clinical decision support (CDS) to aid clinicians with patient care processes, documentation compliance, and resource utilization. We conducted a systematic review of peer-reviewed articles on near real-time and point-of-care CDS within AIMS using the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols. Studies were identified by searches of the electronic databases Medline and EMBASE. Two reviewers screened studies based on title, abstract, and full text. Studies that were similar in intervention and desired outcome were grouped into CDS categories. Three reviewers graded the evidence within each category. The final analysis included 25 articles on CDS as implemented within AIMS. CDS categories included perioperative antibiotic prophylaxis, post-operative nausea and vomiting prophylaxis, vital sign monitors and alarms, glucose management, blood pressure management, ventilator management, clinical documentation, and resource utilization. Of these categories, the reviewers graded perioperative antibiotic prophylaxis and clinical documentation as having strong evidence per the peer reviewed literature. There is strong evidence for the inclusion of near real-time and point-of-care CDS in AIMS to enhance compliance with perioperative antibiotic prophylaxis and clinical documentation. Additional research is needed in many other areas of AIMS-based CDS.

  9. Effect of incorporating a 10 minute point of care test for salivary nicotine metabolites into a general practice based smoking cessation programme: randomised controlled trial.

    PubMed

    Barnfather, Kristian D; Cope, Graham F; Chapple, Iain L

    2005-10-29

    To investigate the effect of immediate feedback from a point of care test for salivary nicotine metabolites in promoting smoking cessation and reduction in tobacco use. Prospective, operator blinded, randomised controlled trial. General dental practice, London. 100 adult smokers. Participants completed a questionnaire on smoking, undertook a clinical examination, and received counselling in smoking cessation. Saliva samples were analysed at presentation and at eight weeks for salivary nicotine metabolites using a 10 minute semiquantitative point of care test. Smoking cessation measured by salivary nicotine metabolite values (scale 0-6), patient feedback on the perceived value of the test (visual analogue scale) in quitting, and reduction in tobacco use. A higher smoking quit rate was achieved with the point of care test (23% cases v 7% controls; P < 0.039), and overall tobacco use also decreased (68% cases v 28% controls; P < 0.001). Baseline values for salivary nicotine metabolites did not differ between the groups (cases, mean 4.1, SD 1.3 and 4.3, 1.4; P = 0.51). 87 participants reattended at eight weeks (44 cases, 43 controls). Mean nicotine metabolite values at eight weeks were 2.58 (2.0) for cases and 4.29 (1.8) for controls (P < 0.001). Incorporation of individualised personal feedback using a point of care test for salivary nicotine metabolites into a general practice based smoking cessation programme increased quit rates by 17% at eight weeks and reduced tobacco use.

  10. Checklist for Early Recognition and Treatment of Acute Illness (CERTAIN): evolution of a content management system for point-of-care clinical decision support.

    PubMed

    Barwise, Amelia; Garcia-Arguello, Lisbeth; Dong, Yue; Hulyalkar, Manasi; Vukoja, Marija; Schultz, Marcus J; Adhikari, Neill K J; Bonneton, Benjamin; Kilickaya, Oguz; Kashyap, Rahul; Gajic, Ognjen; Schmickl, Christopher N

    2016-10-03

    The Checklist for Early Recognition and Treatment of Acute Illness (CERTAIN) is an international collaborative project with the overall objective of standardizing the approach to the evaluation and treatment of critically ill patients world-wide, in accordance with best-practice principles. One of CERTAIN's key features is clinical decision support providing point-of-care information about common acute illness syndromes, procedures, and medications in an index card format. This paper describes 1) the process of developing and validating the content for point-of-care decision support, and 2) the content management system that facilitates frequent peer-review and allows rapid updates of content across different platforms (CERTAIN software, mobile apps, pdf-booklet) and different languages. Content was created based on survey results of acute care providers and validated using an open peer-review process. Over a 3 year period, CERTAIN content expanded to include 67 syndrome cards, 30 procedure cards, and 117 medication cards. 127 (59 %) cards have been peer-reviewed so far. Initially MS Word® and Dropbox® were used to create, store, and share content for peer-review. Recently Google Docs® was used to make the peer-review process more efficient. However, neither of these approaches met our security requirements nor has the capacity to instantly update the different CERTAIN platforms. Although we were able to successfully develop and validate a large inventory of clinical decision support cards in a short period of time, commercially available software solutions for content management are suboptimal. Novel custom solutions are necessary for efficient global point of care content system management.

  11. Exploration of Fluorine Chemistry at the Multidisciplinary Interface of Chemistry and Biology

    PubMed Central

    Ojima, Iwao

    2013-01-01

    Over the last three decades, my engagement in “fluorine chemistry” has evolved substantially, because of the multidisciplinary nature of the research programs. I began my research career as a synthetic chemist in organometallic chemistry and homogeneous catalysis directed toward organic synthesis. Then, I was brought into a very unique world of “fluorine chemistry” in the end of 1970s. I started exploring the interface of fluorine chemistry and transition metal homogeneous catalysis first, which was followed by amino acids, peptides, and peptidomimetics for medicinal chemistry. Since then, I have been exploring the interfaces of fluorine chemistry and multidisciplinary fields of research involving medicinal chemistry, chemical biology, cancer biology and molecular imaging. This perspective intends to cover my fruitful endeavor in the exploration of fluorine chemistry at the multidisciplinary interface of chemistry and biology in a chronological order to show the evolution of my research interest and strategy. PMID:23614876

  12. Covalent-Bond Formation via On-Surface Chemistry.

    PubMed

    Held, Philipp Alexander; Fuchs, Harald; Studer, Armido

    2017-05-02

    In this Review article pioneering work and recent achievements in the emerging research area of on-surface chemistry is discussed. On-surface chemistry, sometimes also called two-dimensional chemistry, shows great potential for bottom-up preparation of defined nanostructures. In contrast to traditional organic synthesis, where reactions are generally conducted in well-defined reaction flasks in solution, on-surface chemistry is performed in the cavity of a scanning probe microscope on a metal crystal under ultrahigh vacuum conditions. The metal first acts as a platform for self-assembly of the organic building blocks and in many cases it also acts as a catalyst for the given chemical transformation. Products and hence success of the reaction are directly analyzed by scanning probe microscopy. This Review provides a general overview of this chemistry highlighting advantages and disadvantages as compared to traditional reaction setups. The second part of the Review then focuses on reactions that have been successfully conducted as on-surface processes. On-surface Ullmann and Glaser couplings are addressed. In addition, cyclodehydrogenation reactions and cycloadditions are discussed and reactions involving the carbonyl functionality are highlighted. Finally, the first examples of sequential on-surface chemistry are considered in which two different functionalities are chemoselectively addressed. The Review gives an overview for experts working in the area but also offers a starting point to non-experts to enter into this exciting new interdisciplinary research field. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Automatic indexing and retrieval of encounter-specific evidence for point-of-care support.

    PubMed

    O'Sullivan, Dympna M; Wilk, Szymon A; Michalowski, Wojtek J; Farion, Ken J

    2010-08-01

    Evidence-based medicine relies on repositories of empirical research evidence that can be used to support clinical decision making for improved patient care. However, retrieving evidence from such repositories at local sites presents many challenges. This paper describes a methodological framework for automatically indexing and retrieving empirical research evidence in the form of the systematic reviews and associated studies from The Cochrane Library, where retrieved documents are specific to a patient-physician encounter and thus can be used to support evidence-based decision making at the point of care. Such an encounter is defined by three pertinent groups of concepts - diagnosis, treatment, and patient, and the framework relies on these three groups to steer indexing and retrieval of reviews and associated studies. An evaluation of the indexing and retrieval components of the proposed framework was performed using documents relevant for the pediatric asthma domain. Precision and recall values for automatic indexing of systematic reviews and associated studies were 0.93 and 0.87, and 0.81 and 0.56, respectively. Moreover, precision and recall for the retrieval of relevant systematic reviews and associated studies were 0.89 and 0.81, and 0.92 and 0.89, respectively. With minor modifications, the proposed methodological framework can be customized for other evidence repositories. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Radiology as the Point of Cancer Patient and Care Team Engagement: Applying the 4R Model at a Patient's Breast Cancer Care Initiation.

    PubMed

    Weldon, Christine B; Friedewald, Sarah M; Kulkarni, Swati A; Simon, Melissa A; Carlos, Ruth C; Strauss, Jonathan B; Bunce, Mikele M; Small, Art; Trosman, Julia R

    2016-12-01

    Radiologists aspire to improve patient experience and engagement, as part of the Triple Aim of health reform. Patient engagement requires active partnerships among health providers and patients, and rigorous teamwork provides a mechanism for this. Patient and care team engagement are crucial at the time of cancer diagnosis and care initiation but are complicated by the necessity to orchestrate many interdependent consultations and care events in a short time. Radiology often serves as the patient entry point into the cancer care system, especially for breast cancer. It is uniquely positioned to play the value-adding role of facilitating patient and team engagement during cancer care initiation. The 4R approach (Right Information and Right Care to the Right Patient at the Right Time), previously proposed for optimizing teamwork and care delivery during cancer treatment, could be applied at the time of diagnosis. The 4R approach considers care for every patient with cancer as a project, using project management to plan and manage care interdependencies, assign clear responsibilities, and designate a quarterback function. The authors propose that radiology assume the quarterback function during breast cancer care initiation, developing the care initiation sequence, as a project care plan for newly diagnosed patients, and engaging patients and their care teams in timely, coordinated activities. After initial consultations and treatment plan development, the quarterback function is transitioned to surgery or medical oncology. This model provides radiologists with opportunities to offer value-added services and solidifies radiology's relevance in the evolving health care environment. To implement 4R at cancer care initiation, it will be necessary to change the radiology practice model to incorporate patient interaction and teamwork, develop 4R content and local adaption approaches, and enrich radiology training with relevant clinical knowledge, patient interaction

  15. Investigating the impact of adding an environmental focus to a developmental chemistry class

    NASA Astrophysics Data System (ADS)

    Robelia, Beth A.

    Making chemistry more relevant to students has been a goal of many curriculum projects. None of these projects have investigated how specific applications of chemistry impact student learning or environmental mindset. The goal of this study was to examine how focusing attention on environmental issues as applications of chemistry concepts would affect students' understanding of general chemistry or environmental chemistry as well environmental attitudes, behaviors and knowledge. Special attention was paid to how women responded to the addition of an environmental focus because prior research indicated women hold more pro-environmental attitudes but are less knowledgeable about environmental topics. The quasi-experimental design used two treatment groups and a comparison group. Both treatment groups received instruction with a Science-Technology-Society orientation, one group focused on environmental applications of chemistry while the other drew applications of chemistry from a number of different fields students might be familiar with such as health care, food science and forensics. The comparison groups used mainly traditional examples from chemistry laboratories. In order to avoid testing the effect of the instructor, two people co-taught both treatment sections. Students in all three groups took a general chemistry assessment at the beginning and end of the course. The treatment groups took a pre and post environmental chemistry assessment and a survey of their environmental attitudes, behaviors and knowledge. Results indicate that students in the environmentally focused section may have made slight gains in general chemistry knowledge. Gains in environmental chemistry knowledge were not significantly different. Students also made modest gains in environmental attitude. Results for women mirrored results for the classes as a whole.

  16. Creating a mobile subject guide to improve access to point-of-care resources for medical students: a case study

    PubMed Central

    Boruff, Jill T; Bilodeau, Edward

    2012-01-01

    Question: Can a mobile optimized subject guide facilitate medical student access to mobile point-of-care tools? Setting: The guide was created at a library at a research-intensive university with six teaching hospital sites. Objectives: The team created a guide facilitating medical student access to point-of-care tools directly on mobile devices to provide information allowing them to access and set up resources with little assistance. Methods: Two librarians designed a mobile optimized subject guide for medicine and conducted a survey to test its usefulness. Results: Web analytics and survey results demonstrate that the guide is used and the students are satisfied. Conclusion: The library will continue to use the subject guide as its primary means of supporting mobile devices. It remains to be seen if the mobile guide facilitates access for those who do not need assistance and want direct access to the resources. Internet access in the hospitals remains an issue. PMID:22272160

  17. 'The history of hindu chemistry' a critical review.

    PubMed

    Harsha, N M; Nagaraja, T N

    2010-10-01

    'The History of Hindu Chemistry' is one of the rare, important books published in twentieth century. Sir Prafulla Chandra Ray, the author of this book, who was a chemist by profession, has contributed greatly to the field of Rasashastra in his own style. The book in two volumes is in English and has achieved international recognition. The work became the cause of enlightening people specially, the Westerners about Indian Alchemy which, they were till then unaware of. In a way, 'globalization' of the concepts of Rasashastra has its starting point in the works of Sir P.C.Ray. The author has touched almost every area of Rasashastra of course, from the standpoint of modern Chemistry. A critical analysis of his contributions, the narration of the contents of the book are detailed in the paper.

  18. Xpert Flu for point-of-care diagnosis of human influenza in industrialized countries.

    PubMed

    Salez, Nicolas; Nougairede, Antoine; Ninove, Laetitia; Zandotti, Christine; de Lamballerie, Xavier; Charrel, Rémi N

    2014-05-01

    Respiratory infections, particularly those caused by influenza viruses, represent the third-most important cause of death in the world due to infectious diseases. Nevertheless, despite the enormous publicity attracted by epidemics due to these viruses, laboratory diagnosis, documentation and recording of respiratory diseases is still unsatisfactory. Available diagnostic tests capable of providing results rapidly are either limited and insufficiently sensitive or highly sensitive and specific but insufficiently rapid. Considerable investment and research efforts have been made towards the development of new diagnostics for influenza A and B viruses and the Xpert(®) Flu assay (Cepheid(®), CA, USA) has emerged as one of the most promising. In this article, we review current knowledge of the Xpert Flu test, discuss its potential value as a point-of-care test and outline the potential leads for future development.

  19. Variation in Point-of-Care Testing of HbA1c in Diabetes Care in General Practice.

    PubMed

    Kristensen, Troels; Waldorff, Frans Boch; Nexøe, Jørgen; Skovsgaard, Christian Volmar; Olsen, Kim Rose

    2017-11-09

    Background: Point-of-care testing (POCT) of HbA1c may result in improved diabetic control, better patient outcomes, and enhanced clinical efficiency with fewer patient visits and subsequent reductions in costs. In 2008, the Danish regulators created a framework agreement regarding a new fee-for-service fee for the remuneration of POCT of HbA1c in general practice. According to secondary research, only the Capital Region of Denmark has allowed GPs to use this new incentive for POCT. The aim of this study is to use patient data to characterize patients with diabetes who have received POCT of HbA1c and analyze the variation in the use of POCT of HbA1c among patients with diabetes in Danish general practice. Methods: We use register data from the Danish Drug Register, the Danish Health Service Register and the National Patient Register from the year 2011 to define a population of 44,981 patients with diabetes (type 1 and type 2 but not patients with gestational diabetes) from the Capital Region. The POCT fee is used to measure the amount of POCT of HbA1c among patients with diabetes. Next, we apply descriptive statistics and multilevel logistic regression to analyze variation in the prevalence of POCT at the patient and clinic level. We include patient characteristics such as gender, age, socioeconomic markers, health care utilization, case mix markers, and municipality classifications. Results: The proportion of patients who received POCT was 14.1% and the proportion of clinics which were "POCT clinics" was 26.9%. There were variations in the use of POCT across clinics and patients. A part of the described variation can be explained by patient characteristics. Male gender, age differences (older age), short education, and other ethnicity imply significantly higher odds for POCT. High patient costs in general practice and other parts of primary care also imply higher odds for POCT. In contrast, high patient costs for drugs and/or morbidity in terms of the Charlson

  20. Variation in Point-of-Care Testing of HbA1c in Diabetes Care in General Practice

    PubMed Central

    Kristensen, Troels; Waldorff, Frans Boch; Nexøe, Jørgen; Skovsgaard, Christian Volmar; Olsen, Kim Rose

    2017-01-01

    Background: Point-of-care testing (POCT) of HbA1c may result in improved diabetic control, better patient outcomes, and enhanced clinical efficiency with fewer patient visits and subsequent reductions in costs. In 2008, the Danish regulators created a framework agreement regarding a new fee-for-service fee for the remuneration of POCT of HbA1c in general practice. According to secondary research, only the Capital Region of Denmark has allowed GPs to use this new incentive for POCT. The aim of this study is to use patient data to characterize patients with diabetes who have received POCT of HbA1c and analyze the variation in the use of POCT of HbA1c among patients with diabetes in Danish general practice. Methods: We use register data from the Danish Drug Register, the Danish Health Service Register and the National Patient Register from the year 2011 to define a population of 44,981 patients with diabetes (type 1 and type 2 but not patients with gestational diabetes) from the Capital Region. The POCT fee is used to measure the amount of POCT of HbA1c among patients with diabetes. Next, we apply descriptive statistics and multilevel logistic regression to analyze variation in the prevalence of POCT at the patient and clinic level. We include patient characteristics such as gender, age, socioeconomic markers, health care utilization, case mix markers, and municipality classifications. Results: The proportion of patients who received POCT was 14.1% and the proportion of clinics which were “POCT clinics” was 26.9%. There were variations in the use of POCT across clinics and patients. A part of the described variation can be explained by patient characteristics. Male gender, age differences (older age), short education, and other ethnicity imply significantly higher odds for POCT. High patient costs in general practice and other parts of primary care also imply higher odds for POCT. In contrast, high patient costs for drugs and/or morbidity in terms of the Charlson

  1. Biochemical sensor tubing for point-of-care monitoring of intravenous drugs and metabolites.

    PubMed

    Choi, Charles J; Wu, Hsin-Yu; George, Sherine; Weyhenmeyer, Jonathan; Cunningham, Brian T

    2012-02-07

    In medical facilities, there is strong motivation to develop detection systems that can provide continuous analysis of fluids in medical tubing used to either deliver or remove fluids from a patient's body. Possible applications include systems that increase the safety of intravenous (IV) drug injection and point-of-care health monitoring. In this work, we incorporated a surface-enhanced Raman scattering (SERS) sensor comprised of an array of closely spaced metal nanodomes into flexible tubing commonly used for IV drug delivery and urinary catheters. The nanodome sensor was fabricated by a low-cost, large-area process that enables single use disposable operation. As exemplary demonstrations, the sensor was used to kinetically detect promethazine (pain medication) and urea (urinary metabolite) within their clinically relevant concentration ranges. Distinct SERS peaks for each analyte were used to demonstrate separate detection and co-detection of the analytes.

  2. Using a geographic information system to enhance patient access to point-of-care diagnostics in a limited-resource setting.

    PubMed

    Ferguson, William J; Kemp, Karen; Kost, Gerald

    2016-03-01

    Rapid and accurate diagnosis drives evidence-based care in health. Point-of-care testing (POCT) aids diagnosis by bringing advanced technologies closer to patients. Health small-world networks are constrained by natural connectivity in the interactions between geography of resources and social forces. Using a geographic information system (GIS) we can understand how populations utilize their health networks, visualize their inefficiencies, and compare alternatives. This project focuses on cardiac care resource in rural Isaan, Thailand. A health care access analysis was created using ArcGIS Network Analyst 10.1 from data representing aggregated population, roads, health resource facilities, and diagnostic technologies. The analysis quantified cardiac health care access and identified ways to improve it using both widespread and resource-limited strategies. Results indicated that having diagnostic technologies closer to populations streamlines critical care paths. GIS allowed us to compare the effectiveness of the implementation strategies and put into perspective the benefits of adopting rapid POCT within health networks. Geospatial analyses derive high impact by improving alternative diagnostic placement strategies in limited-resource settings and by revealing deficiencies in health care access pathways. Additionally, the GIS provides a platform for comparing relative costs, assessing benefits, and improving outcomes. This approach can be implemented effectively by health ministries seeking to enhance cardiac care despite limited resources.

  3. History of Chemistry.

    ERIC Educational Resources Information Center

    Servos, John W.

    1985-01-01

    Discusses the development of chemistry in the United States by considering: (1) chemistry as an evolving body of ideas/techniques, and as a set of conceptual resources affecting and affected by the development of other sciences; and (2) chemistry related to the history of American social and economic institutions and practices. (JN)

  4. A miniaturised image based fluorescence detection system for point-of-care-testing of cocaine abuse

    NASA Astrophysics Data System (ADS)

    Walczak, Rafał; Krüger, Jan; Moynihan, Shane

    2015-08-01

    In this paper, we describe a miniaturised image-based fluorescence detection system and demonstrate its viability as a highly sensitive tool for point-of-care-analysis of drugs of abuse in human sweat with a focus on monitor individuals for drugs of abuse. Investigations of miniaturised and low power optoelectronic configurations and methodologies for real-time image analysis were successfully carried out. The miniaturised fluorescence detection system was validated against a reference detection system under controlled laboratory conditions by analysing spiked sweat samples in dip stick and then strip with sample pad. As a result of the validation studies, a 1 ng mL-1 limit of detection of cocaine in sweat and full agreement of test results with the reference detection system can be reported. Results of the investigations open the way towards a detection system that integrates a hand-held fluorescence reader and a wearable skinpatch, and which can collect and in situ analyse sweat for the presence of cocaine at any point for up to tenths hours.

  5. A new paper-based platform technology for point-of-care diagnostics.

    PubMed

    Gerbers, Roman; Foellscher, Wilke; Chen, Hong; Anagnostopoulos, Constantine; Faghri, Mohammad

    2014-10-21

    Currently, the Lateral flow Immunoassays (LFIAs) are not able to perform complex multi-step immunodetection tests because of their inability to introduce multiple reagents in a controlled manner to the detection area autonomously. In this research, a point-of-care (POC) paper-based lateral flow immunosensor was developed incorporating a novel microfluidic valve technology. Layers of paper and tape were used to create a three-dimensional structure to form the fluidic network. Unlike the existing LFIAs, multiple directional valves are embedded in the test strip layers to control the order and the timing of mixing for the sample and multiple reagents. In this paper, we report a four-valve device which autonomously directs three different fluids to flow sequentially over the detection area. As proof of concept, a three-step alkaline phosphatase based Enzyme-Linked ImmunoSorbent Assay (ELISA) protocol with Rabbit IgG as the model analyte was conducted to prove the suitability of the device for immunoassays. The detection limit of about 4.8 fm was obtained.

  6. Point-of-care HIV tests done by peers, Brazil

    PubMed Central

    Dutra de Barros, Clarissa Habckost; Lobo, Tainah Dourado de Miranda; Pasini, Elisiane Nelcina; Comparini, Regina Aparecida; Caldas de Mesquita, Fábio

    2016-01-01

    Abstract Problem Early diagnosis of infections with human immunodeficiency virus (HIV) is needed – especially among key populations such as sex workers, transgender people, men who have sex with men and people who use drugs. Approach The Brazilian Ministry of Health developed a strategy called Viva Melhor Sabendo (“live better knowing”) to increase HIV testing among key populations. In partnership with nongovernmental organizations (NGOs), a peer point-of-care testing intervention, using an oral fluid rapid test, was introduced at social venues for key populations at different times of the day. Local setting Key populations in Brazil can have 40 times higher HIV prevalence than the general population (14.8% versus 0.4%). Relevant changes Legislation was reinterpreted, so that oral fluid rapid tests could be administered by any person trained in rapid testing by the health ministry. Between January 2014 and March 2015, 29 723 oral fluid tests were administered; 791 (2.7%) were positive. Among the key populations, transgender people had the greatest proportion of positive results (10.7%; 172/1612), followed by men who declared themselves as commercial sex workers (8.7%; 165/1889) and men who have sex with men (4.8%; 292/6055). Lessons learnt The strategy improved access to HIV testing. Testing done by peers at times and locations suitable for key populations increased acceptance of testing. Working with relevant NGOs is a useful approach when reaching out to these key populations. PMID:27516641

  7. Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases.

    PubMed

    Tricoli, Antonio; Neri, Giovanni

    2018-03-22

    This review reports the latest achievements in point-of-care (POC) sensor technologies for the monitoring of ammonia, creatinine and urea in patients suffering of chronic kidney diseases (CKDs). Abnormal levels of these nitrogen biomarkers are found in the physiological fluids, such as blood, urine and sweat, of CKD patients. Delocalized at-home monitoring of CKD biomarkers via integration of miniaturized, portable, and low cost chemical- and bio-sensors in POC devices, is an emerging approach to improve patients' health monitoring and life quality. The successful monitoring of CKD biomarkers, performed on the different body fluids by means of sensors having strict requirements in term of size, cost, large-scale production capacity, response time and simple operation procedures for use in POC devices, is reported and discussed.

  8. Implementation of a virtual vascular clinic with point-of-care ultrasound in an integrated health care system.

    PubMed

    Lin, Judith C; Crutchfield, Janelle M; Zurawski, Dana K; Stevens, Courtney

    2018-02-01

    overall quality responses were overwhelmingly positive. Secured virtual visits can be conducted using commercially available hardware and software solutions. Synchronous telemedicine with point-of-care ultrasound is effective in evaluating common vascular conditions. Virtual care may be used for management of patients with chronic vascular disease. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. In vivo imaging and quantitative analysis of changes in axon length using transgenic zebrafish embryos.

    PubMed

    Kanungo, Jyotshnabala; Lantz, Susan; Paule, Merle G

    2011-01-01

    We describe an imaging procedure to measure axon length in zebrafish embryos in vivo. Automated fluorescent image acquisition was performed with the ImageXpress Micro high content screening reader and further analysis of axon lengths was performed on archived images using AcuityXpress software. We utilized the Neurite Outgrowth Application module with a customized protocol (journal) to measure the axons. Since higher doses of ethanol (2-2.5%, v/v) have been shown to deform motor neurons and axons during development, here we used ethanol to treat transgenic [hb9:GFP (green fluorescent protein)] zebrafish embryos at 28 hpf (hours post-fertilization). These embryos express GFP in the motor neurons and their axons. Embryos after ethanol treatment were arrayed in 384-well plates for automated fluorescent image acquisition in vivo. Average axon lengths of high dose ethanol-treated embryos were significantly lower than the control. Another experiment showed that there was no significant difference in the axon lengths between the embryos grown for 24h at 22°C and 28.5°C. These test experiments demonstrate that using axon development as an end-point, compound screening can be performed in a time-efficient manner. Published by Elsevier Inc.

  10. Nitrate pollution and surface water chemistry in Shimabara, Nagasaki Prefecture, Japan

    NASA Astrophysics Data System (ADS)

    Nakagawa, K.; Amano, H.

    2017-12-01

    Shimabara city has been experiencing serious nitrate pollution in groundwater. To evaluate nitrate pollution and water chemistry in surface water, water samples were collected at 42 sampling points in 15 rivers in Shimabara including a part of Unzen city from January to February 2017. Firstly, spatial distribution of water chemistry was assessed by describing stiff and piper-trilinear diagrams using major ions concentrations. Most of the samples showed Ca-HCO3 or Ca-(NO3+SO4) water types. It corresponds to groundwater chemistry. Some samples were classified into characteristic water types such as Na-Cl, (Na+K)-HCO3, and Ca-Cl. These results indicate sea water mixing and anthropogenic pollution. At the upstream of Nishi-river, although water chemistry showed Ca-HCO3, ions concentrations were higher than that of the other rivers. It indicates that this site was affected by the peripheral anthropogenic activities. Secondly, nitrate-pollution assessment was performed by using NO3-, NO2-, coprostanol (5β(H)-Cholestan-3β-ol), and cholestanol (5α(H)-Cholestan-3β-ol). NO2-N was detected at the 2 sampling points and exceeded drinking standard 0.9 mg L-1 for bottle-fed infants (WHO, 2011). NO3-N + NO2-N concentrations exceeded Japanese drinking standard 10 mg L-1 at 18 sampling points. The highest concentration was 27.5 mg L-1. Higher NO3-N levels were observed in the rivers in the northern parts of the study area. Coprostanol has been used as a fecal contamination indicator, since it can be found in only feces of higher animals. Coprostanol concentrations at 8 sampling points exceeded 700 ng L-1 (Australian drinking water standard). Coprostanol has a potential to distinguish the nitrate pollution sources between chemical fertilizer or livestock wastes, since water samples with similar NO3-N + NO2-N concentration showed distinct coprostanol concentration. The sterols ratio (5β/ (5β+5α)) exceeded 0.5 at 18 sampling points. This reveals that fecal pollution has occurred.

  11. Recent Advances in Point-of-Care Diagnostics for Cardiac Markers

    PubMed Central

    2014-01-01

    National and international cardiology guidelines have recommended a 1-hour turnaround time for reporting results of cardiac troponin to emergency department personnel, measured from the time of blood collection to reporting. Use of point-of-care testing (POCT) can reduce turnaround times for cardiac markers, but current devices are not as precise or sensitive as central laboratory assays. The gap is growing as manufacturers of mainframe immunoassay instruments have or will release troponin assays that are even higher than those currently available. These assays have analytical sensitivity that enables detection of nearly 100% of all healthy subjects which is not possible for current POCT assays. Use of high sensitivity troponin results in a lower value for the 99th percentile of a healthy population. Clinically, this enables for the detection of more cases of myocardial injury. In order to compete analytically, next generation POCT assays will to make technologic advancements, such as the use of microfluidic to better control sample delivery, nanoparticles or nanotubes to increase the surface-to-volume ratios for analytes and antibodies, and novel detection schemes such as chemiluminescence and electrochemical detectors to enhance analytical sensitivity. Multi-marker analysis using POCT is also on the horizon for tests that complement cardiac troponin. PMID:27683464

  12. The Significance of the Origin of Physical Chemistry for Physical Chemistry Education: The Case of Electrolyte Solution Chemistry

    ERIC Educational Resources Information Center

    de Berg, Kevin Charles

    2014-01-01

    Physical Chemistry's birth was fraught with controversy, a controversy about electrolyte solution chemistry which has much to say about how scientific knowledge originates, matures, and responds to challenges. This has direct implications for the way our students are educated in physical chemistry in particular and science in general. The…

  13. Agreement between the 'point of care' tests for microalbuminuria and HbA1c performed in mexican family medicine units and the results of standard laboratory tests.

    PubMed

    Valdez-González, Leticia A; Méndez-Padrón, Araceli; Gómez-Díaz, Rita A; Valladares-Salgado, Adán; Sánchez-Becerra, Martha Catalina; Mondragón-González, Rafael; Hernández-Rubí, Jaime; González-Hermosillo, Arturo; Cruz, Miguel; Borja, Víctor; Wacher, Niels H

    The albumin-creatinine ratio is considered an indicator of microalbuminuria, precursor to chronic kidney disease, while HbA1c is used to measure glycemic control. Given the prevalence of diabetes-related nephropathy, spot testing of albumin has long been recommended as a preventative measure, for the timely detection of microalbuminuria. However, many countries do not have this testing available in primary care, and sometimes not even in second- and third-level care. The objective of this study was to compare agreement of the microalbuminuria and HbA1c results obtained in the laboratory with 'gold standard' techniques, with those obtained on site with a 'Point of Care' DCA Vantage™ device by Siemens. Results for the albumin-creatinine ratio and HbA1c from the Siemens DCA Vantage™ point of care device were compared with those from standard laboratory tests in 25 family medicine units in Mexico City and Toluca, State of Mexico, in patients diagnosed with type-2 diabetes. Agreement between the albumin values of the 2 tests was 0.745 (CI 95% 0.655-0.812). Agreement between the two measurement techniques for HbA1c was 0.970 (CI 95% 0.966-0.973). The results obtained were sufficiently comparative (R i = 0.74 for albumin-creatinine ratio and R i  = 0.97 for HbA1c) to justify the use of the point of care device. Given the high agreement between the point of care device and laboratory tests, this device could be used to identify chronic kidney disease and glycemic control for more adequate treatment in patients with diabetes, especially in remote areas.

  14. Focus Groups and Exit Interviews Are Components of Chemistry Department Program Assessment

    NASA Astrophysics Data System (ADS)

    Dreisbach, Joseph H.; Hogan, Thomas P.; Stamford, Anne Marie; Greggo, John W.

    1998-10-01

    The Chemistry Department, in conjunction with the Assessment and Institutional Research Office (AIRO) and the Department of Counseling and Human Services developed an assessment plan which incorporates use of focus groups and exit interviews. As part of the five-year departmental review, a number of student focus groups were facilitated to evaluate (a) the freshman and sophomore organic chemistry programs which also service other departments and (b) the upper division lecture and laboratory program for majors. Use of direct conversation in program assessment yields less ambiguous results compared with other methods because responses can be clarified with careful follow up questions. Success of this project gave rise to use of annual exit interviews with graduating seniors from the chemistry department. The approach described can easily be modified to meet the needs of any academic setting.

  15. EBMPracticeNet: A Bilingual National Electronic Point-Of-Care Project for Retrieval of Evidence-Based Clinical Guideline Information and Decision Support

    PubMed Central

    2013-01-01

    Background In Belgium, the construction of a national electronic point-of-care information service, EBMPracticeNet, was initiated in 2011 to optimize quality of care by promoting evidence-based decision-making. The collaboration of the government, health care providers, evidence-based medicine (EBM) partners, and vendors of electronic health records (EHR) is unique to this project. All Belgian health care professionals get free access to an up-to-date database of validated Belgian and nearly 1000 international guidelines, incorporated in a portal that also provides EBM information from other sources than guidelines, including computerized clinical decision support that is integrated in the EHRs. Objective The objective of this paper was to describe the development strategy, the overall content, and the management of EBMPracticeNet which may be of relevance to other health organizations creating national or regional electronic point-of-care information services. Methods Several candidate providers of comprehensive guideline solutions were evaluated and one database was selected. Translation of the guidelines to Dutch and French was done with translation software, post-editing by translators and medical proofreading. A strategy is determined to adapt the guideline content to the Belgian context. Acceptance of the computerized clinical decision support tool has been tested and a randomized controlled trial is planned to evaluate the effect on process and patient outcomes. Results Currently, EBMPracticeNet is in "work in progress" state. Reference is made to the results of a pilot study and to further planned research including a randomized controlled trial. Conclusions The collaboration of government, health care providers, EBM partners, and vendors of EHRs is unique. The potential value of the project is great. The link between all the EHRs from different vendors and a national database held on a single platform that is controlled by all EBM organizations in Belgium

  16. Point of care investigations in pediatric care to improve health care in rural areas.

    PubMed

    Walia, Kamini

    2013-07-01

    The good quality laboratory services in developing countries are often limited to major urban centers. As a result, many commercially available high-quality diagnostic tests for infectious diseases are neither accessible nor affordable to patients in the rural areas. Health facilities in rural areas are compromised and this limits the usability and performance of the best medical diagnostic technologies in rural areas as they are designed for air-conditioned laboratories, refrigerated storage of chemicals, a constant supply of calibrators and reagents, stable electrical power, highly trained personnel and rapid transportation of samples. The advent of new technologies have allowed miniaturization and integration of complex functions, which has made it possible for sophisticated diagnostic tools to move out of the developed-world laboratory in the form of a "point of care"(POC) tests. Many diagnostic tests are being developed using these platforms. However, the challenge is to develop diagnostics which are inexpensive, rugged and well suited to the medical and social contexts of the developing world and do not compromise on accuracy and reliability. The already available POC tests which are reliable and affordable, like for HIV infection, malaria, syphilis, and some neglected tropical diseases, and POC tests being developed for other diseases if correctly used and effectively regulated after rigorous evaluation, have the potential to make a difference in clinical management and improve surveillance. In order to use these tests effectively they would need to be supported by technically competent manpower, availability of good-quality reagents, and healthcare providers who value and are able to interpret laboratory results to guide treatment; and a system for timely communication between the laboratory and the healthcare provider. Strengthening the laboratories at the rural level can enable utilization of these diagnostics for improving the diagnosis and management of

  17. Open-source point-of-care electronic medical records for use in resource-limited settings: systematic review and questionnaire surveys

    PubMed Central

    Bru, Juan; Berger, Christopher A

    2012-01-01

    Background Point-of-care electronic medical records (EMRs) are a key tool to manage chronic illness. Several EMRs have been developed for use in treating HIV and tuberculosis, but their applicability to primary care, technical requirements and clinical functionalities are largely unknown. Objectives This study aimed to address the needs of clinicians from resource-limited settings without reliable internet access who are considering adopting an open-source EMR. Study eligibility criteria Open-source point-of-care EMRs suitable for use in areas without reliable internet access. Study appraisal and synthesis methods The authors conducted a comprehensive search of all open-source EMRs suitable for sites without reliable internet access. The authors surveyed clinician users and technical implementers from a single site and technical developers of each software product. The authors evaluated availability, cost and technical requirements. Results The hardware and software for all six systems is easily available, but they vary considerably in proprietary components, installation requirements and customisability. Limitations This study relied solely on self-report from informants who developed and who actively use the included products. Conclusions and implications of key findings Clinical functionalities vary greatly among the systems, and none of the systems yet meet minimum requirements for effective implementation in a primary care resource-limited setting. The safe prescribing of medications is a particular concern with current tools. The dearth of fully functional EMR systems indicates a need for a greater emphasis by global funding agencies to move beyond disease-specific EMR systems and develop a universal open-source health informatics platform. PMID:22763661

  18. Low-cost fluorescence microscopy for point-of-care cell imaging

    NASA Astrophysics Data System (ADS)

    Lochhead, Michael J.; Ives, Jeff; Givens, Monique; Delaney, Marie; Moll, Kevin; Myatt, Christopher J.

    2010-02-01

    Fluorescence microscopy has long been a standard tool in laboratory medicine. Implementation of fluorescence microscopy for near-patient diagnostics, however, has been limited due to cost and complexity associated with traditional fluorescence microscopy techniques. There is a particular need for robust, low-cost imaging in high disease burden areas in the developing world, where access to central laboratory facilities and trained staff is limited. Here we describe a point-of-care assay that combines a disposable plastic cartridge with an extremely low cost fluorescence imaging instrument. Based on a novel, multi-mode planar waveguide configuration, the system capitalizes on advances in volume-manufactured consumer electronic components to deliver an imaging system with minimal moving parts and low power requirements. A two-color cell imager is presented, with magnification optimized for enumeration of immunostained human T cells. To demonstrate the system, peripheral blood mononuclear cells were stained with fluorescently labeled anti-human-CD4 and anti-human-CD3 antibodies. Registered images were used to generate fractional CD4+ and CD3+ staining and enumeration results that show excellent correlation with flow cytometry. The cell imager is under development as a very low cost CD4+ T cell counter for HIV disease management in limited resource settings.

  19. Hook effect in Abbott i-STAT β-human chorionic gonadotropin (β-hCG) point of care assay.

    PubMed

    Wilgen, Urs; Pretorius, Carel J; Gous, Rehna S; Martin, Cameron; Hale, Vincent J; Ungerer, Jacobus P J

    2014-09-01

    Point-of-care testing for β-hCG has been widely advocated to allow rapid diagnosis/exclusion of pregnancy in the emergency department. A quantitative blood β-hCG assay has the additional benefit of being able to monitor the viability of pregnancy, using serial measurements, to determine the appropriate expected increase in β-hCG levels over time (e.g. ectopic pregnancy), and aiding in determining if an intrauterine gestational sac should be visible on sonographic imaging. Evaluation of the newly released Abbott i-STAT β-hCG point-of-care assay with the Beckman Coulter β-hCG laboratory assay in use. Whole blood, plasma and serum samples with a wide range of β-hCG concentrations were analysed by both methods. The Abbott I-STAT β-hCG compares favourably, can be performed on heparinised whole blood, plasma and serum, and shows acceptable accuracy and precision. However a hook effect at elevated β-hCG was shown in gestational trophoblastic disease as well as normal pregnancies. The i-STAT β-hCG performs acceptably in its intended use in the early detection of pregnancy, but results should always be interpreted within the clinical context, as a hook effect may occur. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  20. Relocation of net-acid-generating waste to improve post-mining water chemistry.

    PubMed

    Morin, K A; Hutt, N M

    2001-01-01

    Acidic drainage and metal leaching are long-term environmental liabilities that can persist for many decades to millennia. One technique to improve the water chemistry and ecology of post-mining landscapes is to relocate and submerge net-acid-generating mine materials in a lake or water-retaining impoundment. One example of a carefully executed relocation of waste rock took place at the Eskay Creek Mine in Canada. Pre-relocation studies included an empirical relationship that related (1) the amount of acidity retained by the waste rock during past oxidation to (2) the amount of lime needed in each truckload for neutralization of the acidity and for suppression of metal release. During relocation, thousands of rinse pH measurements indicated net acidity varied significantly over short distances within the waste rock and that acidic rock could not be reliably segregated from near-netural rock. After relocation, water from the watershed continued to be acidic for a few years, then returned to near-neutral pH and near-background concentrations of metals. The chemistry of the lake where the waste rock was submerged remains near background conditions. Therefore, with careful planning and implementation, the relocation and submergence of net-acid-generating materials can greatly improve post-mining water chemistry.

  1. Measuring Meaningful Learning in the Undergraduate Chemistry Laboratory: A National, Cross-Sectional Study

    ERIC Educational Resources Information Center

    Galloway, Kelli R.; Bretz, Stacey Lowery

    2015-01-01

    Research on laboratory learning points to the need to better understand what and how students learn in the undergraduate chemistry laboratory. The Meaningful Learning in the Laboratory Instrument (MLLI) was administered to general and organic chemistry students from 15 colleges and universities across the United States in order to measure the…

  2. An intravenous medication safety system: preventing high-risk medication errors at the point of care.

    PubMed

    Hatcher, Irene; Sullivan, Mark; Hutchinson, James; Thurman, Susan; Gaffney, F Andrew

    2004-10-01

    Improving medication safety at the point of care--particularly for high-risk drugs--is a major concern of nursing administrators. The medication errors most likely to cause harm are administration errors related to infusion of high-risk medications. An intravenous medication safety system is designed to prevent high-risk infusion medication errors and to capture continuous quality improvement data for best practice improvement. Initial testing with 50 systems in 2 units at Vanderbilt University Medical Center revealed that, even in the presence of a fully mature computerized prescriber order-entry system, the new safety system averted 99 potential infusion errors in 8 months.

  3. Upwind MacCormack Euler solver with non-equilibrium chemistry

    NASA Technical Reports Server (NTRS)

    Sherer, Scott E.; Scott, James N.

    1993-01-01

    A computer code, designated UMPIRE, is currently under development to solve the Euler equations in two dimensions with non-equilibrium chemistry. UMPIRE employs an explicit MacCormack algorithm with dissipation introduced via Roe's flux-difference split upwind method. The code also has the capability to employ a point-implicit methodology for flows where stiffness is introduced through the chemical source term. A technique consisting of diagonal sweeps across the computational domain from each corner is presented, which is used to reduce storage and execution requirements. Results depicting one dimensional shock tube flow for both calorically perfect gas and thermally perfect, dissociating nitrogen are presented to verify current capabilities of the program. Also, computational results from a chemical reactor vessel with no fluid dynamic effects are presented to check the chemistry capability and to verify the point implicit strategy.

  4. Computational Chemistry in the Pharmaceutical Industry: From Childhood to Adolescence.

    PubMed

    Hillisch, Alexander; Heinrich, Nikolaus; Wild, Hanno

    2015-12-01

    Computational chemistry within the pharmaceutical industry has grown into a field that proactively contributes to many aspects of drug design, including target selection and lead identification and optimization. While methodological advancements have been key to this development, organizational developments have been crucial to our success as well. In particular, the interaction between computational and medicinal chemistry and the integration of computational chemistry into the entire drug discovery process have been invaluable. Over the past ten years we have shaped and developed a highly efficient computational chemistry group for small-molecule drug discovery at Bayer HealthCare that has significantly impacted the clinical development pipeline. In this article we describe the setup and tasks of the computational group and discuss external collaborations. We explain what we have found to be the most valuable and productive methods and discuss future directions for computational chemistry method development. We share this information with the hope of igniting interesting discussions around this topic. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Point-of-care ultrasonography as a training milestone for internal medicine residents: the time is now.

    PubMed

    Sabath, Bruce F; Singh, Gurkeerat

    2016-01-01

    Point-of-care (POC) ultrasonography is considered fundamental in emergency medicine training and recently has become a milestone in critical care fellowship programs as well. Currently, there is no such standard requirement for internal medicine residency programs in the United States. We present a new case and briefly review another case at our institution - a community hospital - in which internal medicine house staff trained in ultrasonography were able to uncover unexpected and critical diagnoses that significantly changed patient care and outcomes. We also review the growing evidence of the application of ultrasound in the diagnosis of a myriad of conditions encountered in general internal medicine as well as the mounting data on the ability of internal medicine residents to apply this technology accurately at the bedside. We advocate that the literature has sufficiently established the role of POC ultrasonography in general internal medicine that there should no longer be any delay in giving this an official place in the development of internal medicine trainees. This may be particularly useful in the community hospital setting where 24-h echocardiography or other sonography may not be readily available.

  6. Simulation for System Change: Holland Bloorview's Experience Using Simulation to Enhance the Use of Technology at the Point-Of-Care.

    PubMed

    Hubley, Darlene; Peacocke, Sean; Maxwell, Joanne; Parker, Kathryn

    2015-01-01

    Simulation has the potential to invigorate teaching practices, facilitate professional development and impact client care. However, there is little literature on using simulation at the level of organizational change in healthcare. In this paper, the authors explore Holland Bloorview Kids Rehabilitation Hospital's experience using simulation to enhance the use of technology at the point-of-care. The simulation event demonstrated documentation using technology in two typical practice environments and allowed learners to discuss the challenges and opportunities. Participant feedback was positive overall, and this article reveals important lessons to support the future use of simulation as an educational tool for organizational change.

  7. Reliable and valid assessment of point-of-care ultrasonography.

    PubMed

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt; Henriksen, Birthe Merete; Hillingsø, Jens Georg; Konge, Lars; Jensen, Morten Lind; Ringsted, Charlotte

    2015-02-01

    To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. POC US is increasingly used by clinicians and is an essential part of the management of acute surgical conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different surgical patient cases in a controlled set-up. All ultrasound examinations were video-recorded and assessed by 2 blinded radiologists using OSAUS. Reliability was examined using generalizability theory. Construct validity was examined by comparing performance scores between the groups and by correlating physicians' OSAUS scores with diagnostic accuracy. The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores between the novice group (17.0; SD 8.4) and the intermediate group (30.0; SD 10.1), P = 0.007, as well as between the intermediate group and the expert group (72.9; SD 4.4), P = 0.04, and by a high correlation between OSAUS scores and diagnostic accuracy (Spearman ρ correlation coefficient = 0.76; P < 0.001). This study demonstrates high reliability as well as evidence of construct validity of the OSAUS scale for assessment of POC US competence. Hence, the OSAUS scale may be suitable for both in-training as well as end-of-training assessment.

  8. Is Chemistry Attractive for Pupils? Czech Pupils' Perception of Chemistry

    ERIC Educational Resources Information Center

    Kubiatko, Milan

    2015-01-01

    Chemistry is an important subject due to understanding the composition and structure of the things around us. The main aim of the study was to find out the perception of chemistry by lower secondary school pupils. The partial aims were to find out the influence of gender, year of study and favorite subject on the perception of chemistry. The…

  9. Analysis of intraosseous samples using point of care technology--an experimental study in the anaesthetised pig.

    PubMed

    Strandberg, Gunnar; Eriksson, Mats; Gustafsson, Mats G; Lipcsey, Miklós; Larsson, Anders

    2012-11-01

    Intraosseous access is an essential method in emergency medicine when other forms of vascular access are unavailable and there is an urgent need for fluid or drug therapy. A number of publications have discussed the suitability of using intraosseous access for laboratory testing. We aimed to further evaluate this issue and to study the accuracy and precision of intraosseous measurements. Five healthy, anaesthetised pigs were instrumented with bilateral tibial intraosseous cannulae and an arterial catheter. Samples were collected hourly for 6h and analysed for blood gases, acid base status, haemoglobin and electrolytes using an I-Stat point of care analyser. There was no clinically relevant difference between results from left and right intraosseous sites. The variability of the intraosseous sample values, measured as the coefficient of variance (CV), was maximally 11%, and smaller than for the arterial sample values for all variables except SO2. For most variables, there seems to be some degree of systematic difference between intraosseous and arterial results. However, the direction of this difference seems to be predictable. Based on our findings in this animal model, cartridge based point of care instruments appear suitable for the analysis of intraosseous samples. The agreement between intraosseous and arterial analysis seems to be good enough for the method to be clinically useful. The precision, quantified in terms of CV, is at least as good for intraosseous as for arterial analysis. There is no clinically important difference between samples from left and right tibia, indicating a good reproducibility. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. [Point of Care 2.0: Coagulation Monitoring Using Rotem® Sigma and Teg® 6S].

    PubMed

    Weber, Christian Friedrich; Zacharowski, Kai

    2018-06-01

    New-generation methods for point of care based coagulation monitoring enable fully automated viscoelastic analyses for the assessment of particular parts of hemostasis. Contrary to the measuring techniques of former models, the viscoelastic ROTEM ® sigma and TEG ® 6s analyses are performed in single-use test cartridges without time- and personnel-intensive pre-analytical procedures. This review highlights methodical strengths and limitations of the devices and meets concerns associated with their integration in routine clinical practice. Georg Thieme Verlag KG Stuttgart · New York.

  11. Triggering vacuum capillaries for pneumatic pumping and metering liquids in point-of-care immunoassays.

    PubMed

    Weng, Kuo-Yao; Chou, Nien-Jen; Cheng, Jya-Wei

    2008-07-01

    An innovative vacuum capillary pneumatic actuation concept that can be used for point-of-care testing has been investigated. The vacuum glass capillaries are encapsulated within a laminated pouch and incorporated into the fluidic card. Vacuum glass capillaries broken by external force such as finger pressure, generate the pneumatic forces to induce liquid flow in the fluidic system. The sizes of vacuum capillary play a vital role in the pumping and metering functions of the system. The luteinizing hormone (LH) chromatographic immunoassay performances in the fluidic cards show consistency comparable to that obtained by manual micropipetting. The vacuum capillary pneumatic actuation will be applied in other complex handling step bioassays and lab-on-a-chip devices.

  12. Chemistry of the atmosphere: Its impact on global change

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birks, J.W.; Calvert, J.G.; Sievers, R.E.

    1993-12-31

    This book is a summary of the plenary lectures of the CHEMRAWN VII Conference held in Baltimore, Maryland, 2-7 December 1991. The book draws together some interesting perspectives relating to global change from the atmospheric chemistry community from more of a chemist`s point of view than a meteorologist`s. In fact, Chemical Research Applied to World Needs (CHEMRAWN) illustrates how the international atmospheric chemistry community (the meeting was cosponsored by the International Union of Pure and Applied Chemistry and the American Chemical Society) has traditionally put forth a considerable effort to understand the global environmental impact of dumping chemicals into themore » atmosphere. The primary benefit of this book is the concise summary of the research issues confronting the atmospheric science community regarding global change. Being a summary of plenary lectures, the technical depth of the papers is not great. Therefore the book offers a good presentation of material to the nonspecialist who seeks to understand the issues around which the global change research community has focused.« less

  13. Towards Detection and Diagnosis of Ebola Virus Disease at Point-of-Care

    PubMed Central

    Kaushik, Ajeet; Tiwari, Sneham; Jayant, Rahul Dev; Marty, Aileen; Nair, Madhavan

    2015-01-01

    Ebola outbreak-2014 (mainly Zaire strain related Ebola virus) has been declared most widely spread deadly persistent epidemic due to unavailability of rapid diagnostic, detection, and therapeutics. Ebola virus disease (EVD), a severe viral hemorrhagic fever syndrome caused by Ebola virus (EBOV) is transmitted by direct contact with the body fluids of infected person and objects contaminated with virus or infected animals. World Health Organization (WHO) has declared EVD epidemic as public health emergency of international concern with severe global economic burden. At fatal EBOV infection stage, patients usually die before the antibody response. Currently, rapid blood tests to diagnose EBOV infection include the antigen or antibodies capture using ELISA and RNA detection using RT/Q-PCR within 3–10 days after the onset of symptoms. Moreover, few nanotechnology-based colorimetric and paper-based immunoassay methods have been recently reported to detect Ebola virus. Unfortunately, these methods are limited to laboratory only. As state-of-the art (SoA) diagnostics time to confirm Ebola infection, varies from 6 hours to about 3 days, it causes delay in therapeutic approaches. Thus developing a cost-effective, rapid, sensitive, and selective sensor to detect EVD at point-of-care (POC) is certainly worth exploring to establish rapid diagnostics to decide therapeutics. This review highlights SoA of Ebola diagnostics and also a call to develop rapid, selective and sensitive POC detection of EBOV for global health care. We propose that adopting miniaturized electrochemical EBOV immunosensing can detect virus level at pM concentration within ~40 minute compared to 3 days of ELISA test at nM levels. PMID:26319169

  14. Use of error grid analysis to evaluate acceptability of a point of care prothrombin time meter.

    PubMed

    Petersen, John R; Vonmarensdorf, Hans M; Weiss, Heidi L; Elghetany, M Tarek

    2010-02-01

    Statistical methods (linear regression, correlation analysis, etc.) are frequently employed in comparing methods in the central laboratory (CL). Assessing acceptability of point of care testing (POCT) equipment, however, is more difficult because statistically significant biases may not have an impact on clinical care. We showed how error grid (EG) analysis can be used to evaluate POCT PT INR with the CL. We compared results from 103 patients seen in an anti-coagulation clinic that were on Coumadin maintenance therapy using fingerstick samples for POCT (Roche CoaguChek XS and S) and citrated venous blood samples for CL (Stago STAR). To compare clinical acceptability of results we developed an EG with zones A, B, C and D. Using 2nd order polynomial equation analysis, POCT results highly correlate with the CL for CoaguChek XS (R(2)=0. 955) and CoaguChek S (R(2)=0. 93), respectively but does not indicate if POCT results are clinically interchangeable with the CL. Using EG it is readily apparent which levels can be considered clinically identical to the CL despite analytical bias. We have demonstrated the usefulness of EG in determining acceptability of POCT PT INR testing and how it can be used to determine cut-offs where differences in POCT results may impact clinical care. Copyright 2009 Elsevier B.V. All rights reserved.

  15. Collaborative Paradigm of Preventive, Personalized, and Precision Medicine With Point-of-Care Technologies.

    PubMed

    Dhawan, Atam P

    2016-01-01

    Recent advances in biosensors, medical instrumentation, and information processing and communication technologies (ICT) have enabled significant improvements in healthcare. However, these technologies have been mainly applied in clinical environments, such as hospitals and healthcare facilities, under managed care by well-trained and specialized individuals. The global challenge of providing quality healthcare at affordable cost leads to the proposed paradigm of P reventive, Personalized, and Precision Medicine that requires a seamless use of technology and infrastructure support for patients and healthcare providers at point-of-care (POC) locations including homes, semi or pre-clinical facilities, and hospitals. The complexity of the global healthcare challenge necessitates strong collaborative interdisciplinary synergies involving all stakeholder groups including academia, federal research institutions, industry, regulatory agencies, and clinical communities. It is critical to evolve with collaborative efforts on the translation of research to technology development toward clinical validation and potential healthcare applications. This special issue is focused on technology innovation and translational research for POC applications with potential impact in improving global healthcare in the respective areas. Some of these papers were presented at the NIH-IEEE Strategic Conference on Healthcare Innovations and POC Technologies for Precision Medicine (HI-POCT) held at the NIH on November 9-10, 2015. The papers included in the Special Issue provide a spectrum of critical issues and collaborative resources on translational research of advanced POC devices and ICT into global healthcare environment.

  16. Collaborative Paradigm of Preventive, Personalized, and Precision Medicine With Point-of-Care Technologies

    PubMed Central

    2016-01-01

    Recent advances in biosensors, medical instrumentation, and information processing and communication technologies (ICT) have enabled significant improvements in healthcare. However, these technologies have been mainly applied in clinical environments, such as hospitals and healthcare facilities, under managed care by well-trained and specialized individuals. The global challenge of providing quality healthcare at affordable cost leads to the proposed paradigm of P reventive, Personalized, and Precision Medicine that requires a seamless use of technology and infrastructure support for patients and healthcare providers at point-of-care (POC) locations including homes, semi or pre-clinical facilities, and hospitals. The complexity of the global healthcare challenge necessitates strong collaborative interdisciplinary synergies involving all stakeholder groups including academia, federal research institutions, industry, regulatory agencies, and clinical communities. It is critical to evolve with collaborative efforts on the translation of research to technology development toward clinical validation and potential healthcare applications. This special issue is focused on technology innovation and translational research for POC applications with potential impact in improving global healthcare in the respective areas. Some of these papers were presented at the NIH-IEEE Strategic Conference on Healthcare Innovations and POC Technologies for Precision Medicine (HI-POCT) held at the NIH on November 9–10, 2015. The papers included in the Special Issue provide a spectrum of critical issues and collaborative resources on translational research of advanced POC devices and ICT into global healthcare environment. PMID:28560119

  17. Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases

    PubMed Central

    Tricoli, Antonio

    2018-01-01

    This review reports the latest achievements in point-of-care (POC) sensor technologies for the monitoring of ammonia, creatinine and urea in patients suffering of chronic kidney diseases (CKDs). Abnormal levels of these nitrogen biomarkers are found in the physiological fluids, such as blood, urine and sweat, of CKD patients. Delocalized at-home monitoring of CKD biomarkers via integration of miniaturized, portable, and low cost chemical- and bio-sensors in POC devices, is an emerging approach to improve patients’ health monitoring and life quality. The successful monitoring of CKD biomarkers, performed on the different body fluids by means of sensors having strict requirements in term of size, cost, large-scale production capacity, response time and simple operation procedures for use in POC devices, is reported and discussed. PMID:29565315

  18. Cognitive load predicts point-of-care ultrasound simulator performance.

    PubMed

    Aldekhyl, Sara; Cavalcanti, Rodrigo B; Naismith, Laura M

    2018-02-01

    The ability to maintain good performance with low cognitive load is an important marker of expertise. Incorporating cognitive load measurements in the context of simulation training may help to inform judgements of competence. This exploratory study investigated relationships between demographic markers of expertise, cognitive load measures, and simulator performance in the context of point-of-care ultrasonography. Twenty-nine medical trainees and clinicians at the University of Toronto with a range of clinical ultrasound experience were recruited. Participants answered a demographic questionnaire then used an ultrasound simulator to perform targeted scanning tasks based on clinical vignettes. Participants were scored on their ability to both acquire and interpret ultrasound images. Cognitive load measures included participant self-report, eye-based physiological indices, and behavioural measures. Data were analyzed using a multilevel linear modelling approach, wherein observations were clustered by participants. Experienced participants outperformed novice participants on ultrasound image acquisition. Ultrasound image interpretation was comparable between the two groups. Ultrasound image acquisition performance was predicted by level of training, prior ultrasound training, and cognitive load. There was significant convergence between cognitive load measurement techniques. A marginal model of ultrasound image acquisition performance including prior ultrasound training and cognitive load as fixed effects provided the best overall fit for the observed data. In this proof-of-principle study, the combination of demographic and cognitive load measures provided more sensitive metrics to predict ultrasound simulator performance. Performance assessments which include cognitive load can help differentiate between levels of expertise in simulation environments, and may serve as better predictors of skill transfer to clinical practice.

  19. Modified Stereographic Projections of Point Groups and Diagrams of Their Irreducible Representations

    NASA Astrophysics Data System (ADS)

    Kettle, Sidney F. A.

    1999-05-01

    Modified versions of the stereographic projections of the point groups of classical crystallography are presented. They show the consequences of symmetry operations rather than emphasizing the existence of symmetry elements. These projections may be used to give pictures of the irreducible representations of point groups and several examples are given. Such pictures add physical reality to the irreducible representations and facilitate simple lecture demonstration of many important aspects and applications of group theory in chemistry.

  20. Current and future use of point-of-care tests in primary care: an international survey in Australia, Belgium, The Netherlands, the UK and the USA

    PubMed Central

    Howick, Jeremy; Cals, Jochen W L; Jones, Caroline; Price, Christopher P; Plüddemann, Annette; Heneghan, Carl; Berger, Marjolein Y; Buntinx, Frank; Hickner, John; Pace, Wilson; Badrick, Tony; Van den Bruel, Ann; Laurence, Caroline; van Weert, Henk C; van Severen, Evie; Parrella, Adriana; Thompson, Matthew

    2014-01-01

    Objective Despite the growing number of point-of-care (POC) tests available, little research has assessed primary care clinician need for such tests. We therefore aimed to determine which POC tests they actually use or would like to use (if not currently available in their practice). Design Cross-sectional survey. Setting Primary care in Australia, Belgium (Flanders region only), the Netherlands, the UK and the USA. Participants Primary care doctors (general practitioners, family physicians). Main measures We asked respondents to (1) identify conditions for which a POC test could help inform diagnosis, (2) from a list of tests provided: evaluate which POC tests they currently use (and how frequently) and (3) determine which tests (from that same list) they would like to use in the future (and how frequently). Results 2770 primary care clinicians across five countries responded. Respondents in all countries wanted POC tests to help them diagnose acute conditions (infections, acute cardiac disease, pulmonary embolism/deep vein thrombosis), and some chronic conditions (diabetes, anaemia). Based on the list of POC tests provided, the most common tests currently used were: urine pregnancy, urine leucocytes or nitrite and blood glucose. The most commonly reported tests respondents expressed a wish to use in the future were: D-dimer, troponin and chlamydia. The UK and the USA reported a higher actual and desired use for POC tests than Australia, Belgium and the Netherlands. Our limited data suggest (but do not confirm) representativeness. Conclusions Primary care clinicians in all five countries expressed a desire for POC tests to help them diagnose a range of acute and chronic conditions. Rates of current reported use and desired future use were generally high for a small selection of POC tests, but varied across countries. Future research is warranted to explore how specific POC tests might improve primary care. PMID:25107438