Sample records for xt5 systems totalview

  1. Purple L1 Milestone Review Panel TotalView Debugger Functionality and Performance for ASC Purple

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolfe, M

    2006-12-12

    ASC code teams require a robust software debugging tool to help developers quickly find bugs in their codes and get their codes running. Development debugging commonly runs up to 512 processes. Production jobs run up to full ASC Purple scale, and at times require introspection while running. Developers want a debugger that runs on all their development and production platforms and that works with all compilers and runtimes used with ASC codes. The TotalView Multiprocess Debugger made by Etnus was specified for ASC Purple to address this needed capability. The ASC Purple environment builds on the environment seen by TotalViewmore » on ASCI White. The debugger must now operate with the Power5 CPU, Federation switch, AIX 5.3 operating system including large pages, IBM compilers 7 and 9, POE 4.2 parallel environment, and rs6000 SLURM resource manager. Users require robust, basic debugger functionality with acceptable performance at development debugging scale. A TotalView installation must be provided at the beginning of the early user access period that meets these requirements. A functional enhancement, fast conditional data watchpoints, and a scalability enhancement, capability up to 8192 processes, are to be demonstrated.« less

  2. neXtA5: accelerating annotation of articles via automated approaches in neXtProt.

    PubMed

    Mottin, Luc; Gobeill, Julien; Pasche, Emilie; Michel, Pierre-André; Cusin, Isabelle; Gaudet, Pascale; Ruch, Patrick

    2016-01-01

    The rapid increase in the number of published articles poses a challenge for curated databases to remain up-to-date. To help the scientific community and database curators deal with this issue, we have developed an application, neXtA5, which prioritizes the literature for specific curation requirements. Our system, neXtA5, is a curation service composed of three main elements. The first component is a named-entity recognition module, which annotates MEDLINE over some predefined axes. This report focuses on three axes: Diseases, the Molecular Function and Biological Process sub-ontologies of the Gene Ontology (GO). The automatic annotations are then stored in a local database, BioMed, for each annotation axis. Additional entities such as species and chemical compounds are also identified. The second component is an existing search engine, which retrieves the most relevant MEDLINE records for any given query. The third component uses the content of BioMed to generate an axis-specific ranking, which takes into account the density of named-entities as stored in the Biomed database. The two ranked lists are ultimately merged using a linear combination, which has been specifically tuned to support the annotation of each axis. The fine-tuning of the coefficients is formally reported for each axis-driven search. Compared with PubMed, which is the system used by most curators, the improvement is the following: +231% for Diseases, +236% for Molecular Functions and +3153% for Biological Process when measuring the precision of the top-returned PMID (P0 or mean reciprocal rank). The current search methods significantly improve the search effectiveness of curators for three important curation axes. Further experiments are being performed to extend the curation types, in particular protein-protein interactions, which require specific relationship extraction capabilities. In parallel, user-friendly interfaces powered with a set of JSON web services are currently being

  3. neXtA5: accelerating annotation of articles via automated approaches in neXtProt

    PubMed Central

    Mottin, Luc; Gobeill, Julien; Pasche, Emilie; Michel, Pierre-André; Cusin, Isabelle; Gaudet, Pascale; Ruch, Patrick

    2016-01-01

    The rapid increase in the number of published articles poses a challenge for curated databases to remain up-to-date. To help the scientific community and database curators deal with this issue, we have developed an application, neXtA5, which prioritizes the literature for specific curation requirements. Our system, neXtA5, is a curation service composed of three main elements. The first component is a named-entity recognition module, which annotates MEDLINE over some predefined axes. This report focuses on three axes: Diseases, the Molecular Function and Biological Process sub-ontologies of the Gene Ontology (GO). The automatic annotations are then stored in a local database, BioMed, for each annotation axis. Additional entities such as species and chemical compounds are also identified. The second component is an existing search engine, which retrieves the most relevant MEDLINE records for any given query. The third component uses the content of BioMed to generate an axis-specific ranking, which takes into account the density of named-entities as stored in the Biomed database. The two ranked lists are ultimately merged using a linear combination, which has been specifically tuned to support the annotation of each axis. The fine-tuning of the coefficients is formally reported for each axis-driven search. Compared with PubMed, which is the system used by most curators, the improvement is the following: +231% for Diseases, +236% for Molecular Functions and +3153% for Biological Process when measuring the precision of the top-returned PMID (P0 or mean reciprocal rank). The current search methods significantly improve the search effectiveness of curators for three important curation axes. Further experiments are being performed to extend the curation types, in particular protein–protein interactions, which require specific relationship extraction capabilities. In parallel, user-friendly interfaces powered with a set of JSON web services are currently being

  4. Evaluation of red blood cell and platelet antigen genotyping platforms (ID CORE XT/ID HPA XT) in routine clinical practice.

    PubMed

    Finning, Kirstin; Bhandari, Radhika; Sellers, Fiona; Revelli, Nicoletta; Villa, Maria Antonietta; Muñiz-Díaz, Eduardo; Nogués, Núria

    2016-03-01

    High-throughput genotyping platforms enable simultaneous analysis of multiple polymorphisms for blood group typing. BLOODchip® ID is a genotyping platform based on Luminex® xMAP technology for simultaneous determination of 37 red blood cell (RBC) antigens (ID CORE XT) and 18 human platelet antigens (HPA) (ID HPA XT) using the BIDS XT software. In this international multicentre study, the performance of ID CORE XT and ID HPA XT, using the centres' current genotyping methods as the reference for comparison, and the usability and practicality of these systems, were evaluated under working laboratory conditions. DNA was extracted from whole blood in EDTA with Qiagen methodologies. Ninety-six previously phenotyped/genotyped samples were processed per assay: 87 testing samples plus five positive controls and four negative controls. Results were available for 519 samples: 258 with ID CORE XT and 261 with ID HPA XT. There were three "no calls" that were either caused by human error or resolved after repeating the test. Agreement between the tests and reference methods was 99.94% for ID CORE XT (9,540/9,546 antigens determined) and 100% for ID HPA XT (all 4,698 alleles determined). There were six discrepancies in antigen results in five RBC samples, four of which (in VS, N, S and Do(a)) could not be investigated due to lack of sufficient sample to perform additional tests and two of which (in S and C) were resolved in favour of ID CORE XT (100% accuracy). The total hands-on time was 28-41 minutes for a batch of 16 samples. Compared with the reference platforms, ID CORE XT and ID HPA XT were considered simpler to use and had shorter processing times. ID CORE XT and ID HPA XT genotyping platforms for RBC and platelet systems were accurate and user-friendly in working laboratory settings.

  5. A performance evaluation of the IBM 370/XT personal computer

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Triantafyllopoulos, Spiros

    1984-01-01

    An evaluation of the IBM 370/XT personal computer is given. This evaluation focuses primarily on the use of the 370/XT for scientific and technical applications and applications development. A measurement of the capabilities of the 370/XT was performed by means of test programs which are presented. Also included is a review of facilities provided by the operating system (VM/PC), along with comments on the IBM 370/XT hardware configuration.

  6. Development of potent anti-infective agents from Silurana tropicalis: conformational analysis of the amphipathic, alpha-helical antimicrobial peptide XT-7 and its non-haemolytic analogue [G4K]XT-7.

    PubMed

    Subasinghage, Anusha P; Conlon, J Michael; Hewage, Chandralal M

    2010-04-01

    Peptide XT-7 (GLLGP(5)LLKIA(10)AKVGS(15)NLL.NH(2)) is a cationic, leucine-rich peptide, first isolated from skin secretions of the frog, Silurana tropicalis (Pipidae). The peptide shows potent, broad-spectrum antimicrobial activity but its therapeutic potential is limited by haemolytic activity (LC(50)=140 microM). The analogue [G4K]XT-7, however, retains potent antimicrobial activity but is non-haemolytic (LC(50)>500 microM). In order to elucidate the molecular basis for this difference in properties, the three dimensional structures of XT-7 and the analogue have been investigated by proton NMR spectroscopy and molecular modelling. In aqueous solution, both peptides lack secondary structure. In a 2,2,2-trifluoroethanol (TFE-d(3))-H(2)O mixed solvent system, XT-7 is characterised by a right handed alpha-helical conformation between residues Leu(3) and Leu(17) whereas [G4K]XT-7 adopts a more restricted alpha-helical conformation between residues Leu(6) and Leu(17). A similar conformation for XT-7 in 1,2-dihexanoyl-sn-glycero-3-phosphocholine (DHPC) micellular media was observed with a helical segment between Leu(3) and Leu(17). However, differences in side chain orientations restricting the hydrophilic residues to a smaller patch resulted in an increased hydrophobic surface relative to the conformation in TFE-H(2)O. Molecular modelling of the structures obtained in our study demonstrates the amphipathic character of the helical segments. It is proposed that the marked decrease in haemolytic activity produced by the substitution Gly(4)-->Lys in XT-7 arises from a decrease in both helicity and hydrophobicity. These studies may facilitate the development of potent but non-toxic anti-infective agents based upon the structure of XT-7. Copyright 2009 Elsevier B.V. All rights reserved.

  7. Ada/Xt Architecture: Design Report for the Software Technology for Adaptable, Reliable Systems (STARS)

    DTIC Science & Technology

    1990-01-25

    N Task: UR20 CDRL: 01000 N UR2O--ProcesslEnvironmentx Ada/Xt. Architecture : Design Report ~ ~ fFCp Informal Technical Data I? ,LECp Sofwar Tehoog for...S. FUNDING NUMBERS Ada/Xt Architecture : Design Report STARS Contract 6.AUTHOR(S)_ Ft9628-88-D-0031 6. AUTHOR(S) Kurt Wallnau 7. PERFORMING...of the STARS Prime contract under the Process Environment Integration task (UR20). This document "Ada Xt Architecture : Design Report", type A005

  8. Integration of CW / Radionucleotide Detection Systems to the Fido XT Explosives Detector

    DTIC Science & Technology

    2008-07-31

    explosives detected by the Fido XT. Additionally, a platform for centralized storage and processing of Fido XT data files collected in house, targeted...fused silica glass wool (obtained from Restek). The fluorescent signal was easily washed out of the flow cell by a nominal amount of buffer...detector with supporting NRE was processed . The Interceptor components were configured to operate under a Windows CE processor environment, and to

  9. CLIPS on the NeXT computer

    NASA Technical Reports Server (NTRS)

    Charnock, Elizabeth; Eng, Norman

    1990-01-01

    This paper discusses the integration of CLIPS into a hybrid expert system neural network AI tool for the NeXT computer. The main discussion is devoted to the joining of these two AI paradigms in a mutually beneficial relationship. We conclude that expert systems and neural networks should not be considered as competing AI implementation methods, but rather as complimentary components of a whole.

  10. Self-expanding Portico Valve Versus Balloon-expandable SAPIEN XT Valve in Patients With Small Aortic Annuli: Comparison of Hemodynamic Performance.

    PubMed

    Del Trigo, María; Dahou, Abdellaziz; Webb, John G; Dvir, Danny; Puri, Rishi; Abdul-Jawad Altisent, Omar; Campelo-Parada, Francisco; Thompson, Chris; Leipsic, Jonathon; Stub, Dion; DeLarochellière, Robert; Paradis, Jean-Michel; Dumont, Eric; Doyle, Daniel; Mohammadi, Siamak; Pasian, Sergio; Côté, Melanie; Pibarot, Philippe; Rodés-Cabau, Josep

    2016-05-01

    The self-expanding Portico valve is a new transcatheter aortic valve system yielding promising preliminary results, yet there are no comparative data against earlier generation transcatheter aortic valve systems. The aim of this study was to compare the hemodynamic performance of the Portico and balloon-expandable SAPIEN XT valves in a case-matched study with echocardiographic core laboratory analysis. Twenty-two patients underwent transcatheter aortic valve implantation with the Portico 23-mm valve and were matched for aortic annulus area and mean diameter measured by multidetector computed tomography, left ventricular ejection fraction, body surface area, and body mass index with 40 patients treated with the 23-mm SAPIEN XT. Mean aortic annulus diameters were 19.6±1.3mm by transthoracic echocardiography and 21.4±1.2mm by computed tomography, with no significant between-group differences. Doppler echocardiographic images were collected at baseline and at 1-month of follow-up and were analyzed in a central echocardiography core laboratory. There were no significant between-group differences in residual mean transaortic gradients (SAPIEN XT: 10.4±3.7mmHg; Portico: 9.8±1.1mmHg; P=.49) and effective orifice areas (SAPIEN XT: 1.36±0.27cm(2); Portico, 1.37±.29cm(2); P=.54). Rates of severe prosthesis-patient mismatch (effective orifice area<0.65cm(2)/m(2)) were similar (SAPIEN XT: 13.5%; Portico: 10.0%; P=.56). No between-group differences were found in the occurrence of moderate-severe paravalvular leaks (5.0% vs 4.8% of SAPIEN XT and Portico respectively; P=.90). Transcatheter aortic valve implantation with the self-expanding Portico system yielded similar short-term hemodynamic performance compared with the balloon-expandable SAPIEN XT system for treating patients with severe aortic stenosis and small annuli. Further prospective studies with longer-term follow-up and in patients with larger aortic annuli are required. Copyright © 2015 Sociedad Española de

  11. Accuracy of the Garmin 920 XT HRM to perform HRV analysis.

    PubMed

    Cassirame, Johan; Vanhaesebrouck, Romain; Chevrolat, Simon; Mourot, Laurent

    2017-12-01

    Heart rate variability (HRV) analysis is widely used to investigate autonomous cardiac drive. This method requires periodogram measurement, which can be obtained by an electrocardiogram (ECG) or from a heart rate monitor (HRM), e.g. the Garmin 920 XT device. The purpose of this investigation was to assess the accuracy of RR time series measurements from a Garmin 920 XT HRM as compared to a standard ECG, and to verify whether the measurements thus obtained are suitable for HRV analysis. RR time series were collected simultaneously with an ECG (Powerlab system, AD Instruments, Castell Hill, Australia) and a Garmin XT 920 in 11 healthy subjects during three conditions, namely in the supine position, the standing position and during moderate exercise. In a first step, we compared RR time series obtained with both tools using the Bland and Altman method to obtain the limits of agreement in all three conditions. In a second step, we compared the results of HRV analysis between the ECG RR time series and Garmin 920 XT series. Results show that the accuracy of this system is in accordance with the literature in terms of the limits of agreement. In the supine position, bias was 0.01, - 2.24, + 2.26 ms; in the standing position, - 0.01, - 3.12, + 3.11 ms respectively, and during exercise, - 0.01, - 4.43 and + 4.40 ms. Regarding HRV analysis, we did not find any difference for HRV analysis in the supine position, but the standing and exercise conditions both showed small modifications.

  12. Measurements of particle backscatter, extinction, and lidar ratio at 1064 nm with the rotational raman method in Polly-XT

    NASA Astrophysics Data System (ADS)

    Engelmann, Ronny; Haarig, Moritz; Baars, Holger; Ansmann, Albert; Kottas, Michael; Marinou, Eleni

    2018-04-01

    We replaced a 1064-nm interference filter of a Polly-XT lidar system by a 1058-nm filter to observe pure rotational Raman backscattering from atmospheric Nitrogen and Oxygen. Polly-XT is compact Raman lidar with a Nd:YAG laser (20 Hz, 200 mJ at 1064 nm) and a 30-cm telescope mirror which applies photomultipliers in photoncounting mode. We present the first measured signals at 1058 nm and the derived extinction profile from measurements aboard RV Polarstern and in Leipzig. In combination with another Polly-XT system we could also derive particle backscatter and lidar ratio profiles at 1064 nm.

  13. The JPEG XT suite of standards: status and future plans

    NASA Astrophysics Data System (ADS)

    Richter, Thomas; Bruylants, Tim; Schelkens, Peter; Ebrahimi, Touradj

    2015-09-01

    The JPEG standard has known an enormous market adoption. Daily, billions of pictures are created, stored and exchanged in this format. The JPEG committee acknowledges this success and spends continued efforts in maintaining and expanding the standard specifications. JPEG XT is a standardization effort targeting the extension of the JPEG features by enabling support for high dynamic range imaging, lossless and near-lossless coding, and alpha channel coding, while also guaranteeing backward and forward compatibility with the JPEG legacy format. This paper gives an overview of the current status of the JPEG XT standards suite. It discusses the JPEG legacy specification, and details how higher dynamic range support is facilitated both for integer and floating-point color representations. The paper shows how JPEG XT's support for lossless and near-lossless coding of low and high dynamic range images is achieved in combination with backward compatibility to JPEG legacy. In addition, the extensible boxed-based JPEG XT file format on which all following and future extensions of JPEG will be based is introduced. This paper also details how the lossy and lossless representations of alpha channels are supported to allow coding transparency information and arbitrarily shaped images. Finally, we conclude by giving prospects on upcoming JPEG standardization initiative JPEG Privacy & Security, and a number of other possible extensions in JPEG XT.

  14. Conduction Abnormalities and Pacemaker Implantations After SAPIEN 3 Vs SAPIEN XT Prosthesis Aortic Valve Implantation.

    PubMed

    Husser, Oliver; Kessler, Thorsten; Burgdorf, Christof; Templin, Christian; Pellegrini, Costanza; Schneider, Simon; Kasel, Albert Markus; Kastrati, Adnan; Schunkert, Heribert; Hengstenberg, Christian

    2016-02-01

    Transcatheter aortic valve implantation is increasingly used in patients with aortic stenosis. Post-procedural intraventricular conduction abnormalities and permanent pacemaker implantations remain a serious concern. Recently, the Edwards SAPIEN 3 prosthesis has replaced the SAPIEN XT. We sought to determine the incidences of new-onset intraventricular conduction abnormalities and permanent pacemaker implantations by comparing the 2 devices. We analyzed the last consecutive 103 patients undergoing transcatheter aortic valve implantation with SAPIEN XT before SAPIEN 3 was used in the next 105 patients. To analyze permanent pacemaker implantations and new-onset intraventricular conduction abnormalities, patients with these conditions at baseline were excluded. Electrocardiograms were recorded at baseline, after the procedure, and before discharge. SAPIEN 3 was associated with higher device success (100% vs 92%; P=.005) and less paravalvular leakage (0% vs 7%; P<.001). The incidence of permanent pacemaker implantations was 12.6% (23 of 183) with no difference between the 2 groups (SAPIEN 3: 12.5% [12 of 96] vs SAPIEN XT: 12.6% [11 of 87]; P=.99). SAPIEN 3 was associated with a higher rate of new-onset intraventricular conduction abnormalities (49% vs 27%; P=.007) due to a higher rate of fascicular blocks (17% vs 5%; P=.021). There was no statistically significant difference in transient (29% [20 of 69] vs persistent 19% [12 of 64]; P=.168) left bundle branch blocks (28% [19 of 69] vs 17% [11 of 64]; P=.154) when SAPIEN 3 was compared with SAPIEN XT. We found a trend toward a higher rate of new-onset intraventricular conduction abnormalities with SAPIEN 3 compared with SAPIEN XT, although this did not result in a higher permanent pacemaker implantation rate. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  15. Early outcomes of percutaneous pulmonary valve implantation using the Edwards SAPIEN XT transcatheter heart valve system.

    PubMed

    Haas, Nikolaus A; Carere, Ronald Giacomo; Kretschmar, Oliver; Horlick, Eric; Rodés-Cabau, Josep; de Wolf, Daniël; Gewillig, Marc; Mullen, Michael; Lehner, Anja; Deutsch, Cornelia; Bramlage, Peter; Ewert, Peter

    2018-01-01

    Patients with congenital or acquired heart defects affecting the pulmonary valve and right ventricular outflow tract (RVOT) commonly require multiple surgical interventions, resulting in significant morbidity. A less invasive alternative is percutaneous pulmonary valve implantation (PPVI). Though studies have previously reported the safety and efficacy of the early generation transcatheter heart valves (THVs), data on more recent devices are severely lacking. We performed a multinational, multicentre, retrospective, observational registry analysis of patients who underwent PPVI using the Edwards SAPIEN XT THV. Of the 46 patients that were enrolled, the majority had tetralogy of Fallot as the underlying diagnosis (58.7%), and stentless xenograft as the most common RVOT anatomy (34.8%). Procedural success rate was high (93.5%), with a low frequency of periprocedural complications and adverse events (6.5% and 10.9%, respectively). At 30days post-procedure, NYHA class had improved significantly (90.6% were at NYHA I or II). The rate of moderate/severe pulmonary regurgitation had decreased from 76.1% at baseline to 5.0% at 30days, and the calculated peak systolic gradient had decreased from 45.2 (SD±21.3) mmHg to 16.4 (SD±8.0) mmHg, with these values remaining low up to 2years. The data suggest the efficacy and safety of the SAPIEN XT THV in PPVI in common anatomies in patients with conduits, as well as those with native pulmonary valves or transannular patches. Continued data collection is necessary to verify long-term findings. CLINICALTRIALS. NCT02302131. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. A College That Relied on NeXT Computers Plans To Switch to Apple.

    ERIC Educational Resources Information Center

    Wilson, David L.

    1997-01-01

    Allegheny College (Pennsylvania), which uses NeXT computers, was dismayed when the technically superior operating system was orphaned but are now delighted that the company has been bought by Apple Computer and will make the operating system standard on Apple computers. The object-oriented operating system allows relatively unsophisticated users…

  17. In-orbit results of Delfi-n3Xt: Lessons learned and move forward

    NASA Astrophysics Data System (ADS)

    Guo, Jian; Bouwmeester, Jasper; Gill, Eberhard

    2016-04-01

    This paper provides an update of the Delfi nanosatellite programme of the Delft University of Technology (TU Delft), with a focus on the recent in-orbit results of the second TU Delft satellite Delfi-n3Xt. In addition to the educational objective that has been reached with more than 80 students involved in the project, most of the technological objectives of Delfi-n3Xt have also been fulfilled with successful in-orbit demonstrations of payloads and platform. Among these demonstrations, four are highlighted in this paper, including a solid cool gas micropropulsion system, a new type of solar cell, a more robust Command and Data Handling Subsystem (CDHS), and a highly integrated Attitude Determination and Control Subsystem (ADCS) that performs three-axis active control using reaction wheels. Through the development of Delfi-n3Xt, significant experiences and lessons have been learned, which motivated a further step towards DelFFi, the third Delfi CubeSat mission, to demonstrate autonomous formation flying using two CubeSats named Delta and Phi. A brief update of the DelFFi mission is also provided.

  18. An overview of the Progenika ID CORE XT: an automated genotyping platform based on a fluidic microarray system.

    PubMed

    Goldman, Mindy; Núria, Núria; Castilho, Lilian M

    2015-01-01

    Automated testing platforms facilitate the introduction of red cell genotyping of patients and blood donors. Fluidic microarray systems, such as Luminex XMAP (Austin, TX), are used in many clinical applications, including HLA and HPA typing. The Progenika ID CORE XT (Progenika Biopharma-Grifols, Bizkaia, Spain) uses this platform to analyze 29 polymorphisms determining 37 antigens in 10 blood group systems. Once DNA has been extracted, processing time is approximately 4 hours. The system is highly automated and includes integrated analysis software that produces a file and a report with genotype and predicted phenotype results.

  19. NeXT Application Development Workshop. [Use and Design of Instructional Applications on the NeXT Computer.

    ERIC Educational Resources Information Center

    Kiel, Don; And Others

    Instructional applications for NeXT computers were developed by nine faculty members from the biology, mathematics and computer science, fine arts, chemistry, physics and astronomy, and geology departments as part of a grant awarded to the California State University at Los Angeles. These notes provide a schedule of events and reports from a 2-day…

  20. Enamel shear bond strength of two orthodontic self-etching bonding systems compared to Transbond™ XT.

    PubMed

    Hellak, Andreas; Rusdea, Patrick; Schauseil, Michael; Stein, Steffen; Korbmacher-Steiner, Heike Maria

    2016-11-01

    The aim of this in vitro study was to compare the shear bond strength (SBS) and Adhesive Remnant Index (ARI) scores of two self-etching no-mix adhesives (Prompt L-Pop™ and Scotchbond™) for orthodontic appliances to the commonly used total etch system Transbond XT™ (in combination with phosphoric acid). In all, 60 human premolars were randomly divided into three groups of 20 specimens each. In group 1 (control), brackets were bonded with Transbond™ XT primer. Prompt L-Pop™ (group 2) and Scotchbond™ Universal (group 3) were used in the experimental groups. Lower premolar brackets were bonded by light curing the adhesive. After 24 h of storage, the shear bond strength (SBS) was measured using a Zwicki 1120 testing machine. The adhesive remnant index (ARI) was determined under 10× magnification. The Kruskal-Wallis test was used to statistically compare the SBS and the ARI scores. No significant differences in the SBS between any of the experimental groups were detected (group 1: 15.49 ± 3.28 MPa; group 2: 13.89 ± 4.95 MPa; group 3: 14.35 ± 3.56 MPa; p = 0.489), nor were there any significant differences in the ARI scores (p = 0.368). Using the two self-etching no-mix adhesives (Prompt L-Pop™ and Scotchbond™) for orthodontic appliances does not affect either the SBS or ARI scores in comparison with the commonly used total-etch system Transbond™ XT. In addition, Scotchbond™ Universal supports bonding on all types of surfaces (enamel, metal, composite, and porcelain) with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures.

  1. Integrating Grid Services into the Cray XT4 Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NERSC; Cholia, Shreyas; Lin, Hwa-Chun Wendy

    2009-05-01

    The 38640 core Cray XT4"Franklin" system at the National Energy Research Scientific Computing Center (NERSC) is a massively parallel resource available to Department of Energy researchers that also provides on-demand grid computing to the Open Science Grid. The integration of grid services on Franklin presented various challenges, including fundamental differences between the interactive and compute nodes, a stripped down compute-node operating system without dynamic library support, a shared-root environment and idiosyncratic application launching. Inour work, we describe how we resolved these challenges on a running, general-purpose production system to provide on-demand compute, storage, accounting and monitoring services through generic gridmore » interfaces that mask the underlying system-specific details for the end user.« less

  2. OPAL: An Open-Source MPI-IO Library over Cray XT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Weikuan; Vetter, Jeffrey S; Canon, Richard Shane

    Parallel IO over Cray XT is supported by a vendor-supplied MPI-IO package. This package contains a proprietary ADIO implementation built on top of the sysio library. While it is reasonable to maintain a stable code base for application scientists' convenience, it is also very important to the system developers and researchers to analyze and assess the effectiveness of parallel IO software, and accordingly, tune and optimize the MPI-IO implementation. A proprietary parallel IO code base relinquishes such flexibilities. On the other hand, a generic UFS-based MPI-IO implementation is typically used on many Linux-based platforms. We have developed an open-source MPI-IOmore » package over Lustre, referred to as OPAL (OPportunistic and Adaptive MPI-IO Library over Lustre). OPAL provides a single source-code base for MPI-IO over Lustre on Cray XT and Linux platforms. Compared to Cray implementation, OPAL provides a number of good features, including arbitrary specification of striping patterns and Lustre-stripe aligned file domain partitioning. This paper presents the performance comparisons between OPAL and Cray's proprietary implementation. Our evaluation demonstrates that OPAL achieves the performance comparable to the Cray implementation. We also exemplify the benefits of an open source package in revealing the underpinning of the parallel IO performance.« less

  3. Performance evaluation of the Abbott CELL-DYN Ruby and the Sysmex XT-2000i haematology analysers.

    PubMed

    Leers, M P G; Goertz, H; Feller, A; Hoffmann, J J M L

    2011-02-01

    Two mid-range haematology analysers (Abbott CELL-DYN Ruby and Sysmex XT-2000i) were evaluated to determine their analytical performance and workflow efficiency in the haematology laboratory. In total 418 samples were processed for determining equivalence of complete blood count (CBC) measurements, and 100 for reticulocyte comparison. Blood smears served for assessing the agreement of the differential counts. Inter-instrument agreement for most parameters was good although small numbers of discrepancies were observed. Systematic biases were found for mean cell volume, reticulocytes, platelets and mean platelet volume. CELL-DYN Ruby WBC differentials were obtained with all samples while the XT-2000i suppressed differentials partially or completely in 13 samples (3.1%). WBC subpopulation counts were otherwise in good agreement with no major outliers. Following first-pass CBC/differential analysis, 88 (21%) of XT-2000i samples required further analyser processing compared to 18 (4.3%) for the CELL-DYN Ruby. Smear referrals for suspected WBC/nucleated red blood cells and platelet abnormalities were indicated for 106 (25.4%) and 95 (22.7%) of the XT-2000i and CELL-DYN Ruby samples respectively. Flagging efficiencies for both analysers were found to be similar. The Sysmex XT-2000i and Abbott CELL-DYN Ruby analysers have broadly comparable analytical performance, but the CELL-DYN Ruby showed superior first-pass efficiency. © 2010 Blackwell Publishing Ltd.

  4. Documentation for the “XT3D” option in the Node Property Flow (NPF) Package of MODFLOW 6

    USGS Publications Warehouse

    Provost, Alden M.; Langevin, Christian D.; Hughes, Joseph D.

    2017-08-10

    This report describes the “XT3D” option in the Node Property Flow (NPF) Package of MODFLOW 6. The XT3D option extends the capabilities of MODFLOW by enabling simulation of fully three-dimensional anisotropy on regular or irregular grids in a way that properly takes into account the full, three-dimensional conductivity tensor. It can also improve the accuracy of groundwater-flow simulations in cases in which the model grid violates certain geometric requirements. Three example problems demonstrate the use of the XT3D option to simulate groundwater flow on irregular grids and through three-dimensional porous media with anisotropic hydraulic conductivity.Conceptually, the XT3D method of estimating flow between two MODFLOW 6 model cells can be viewed in terms of three main mathematical steps: construction of head-gradient estimates by interpolation; construction of fluid-flux estimates by application of the full, three-dimensional form of Darcy’s Law, in which the conductivity tensor can be heterogeneous and anisotropic; and construction of the flow expression by enforcement of continuity of flow across the cell interface. The resulting XT3D flow expression, which relates the flow across the cell interface to the values of heads computed at neighboring nodes, is the sum of terms in which conductance-like coefficients multiply head differences, as in the conductance-based flow expression the NPF Package uses by default. However, the XT3D flow expression contains terms that involve “neighbors of neighbors” of the two cells for which the flow is being calculated. These additional terms have no analog in the conductance-based formulation. When assembled into matrix form, the XT3D formulation results in a larger stencil than the conductance-based formulation; that is, each row of the coefficient matrix generally contains more nonzero elements. The “RHS” suboption can be used to avoid expanding the stencil by placing the additional terms on the right-hand side

  5. Comparison of acute elastic recoil between the SAPIEN-XT and SAPIEN valves in transfemoral-transcatheter aortic valve replacement.

    PubMed

    Garg, Aatish; Parashar, Akhil; Agarwal, Shikhar; Aksoy, Olcay; Hammadah, Muhammad; Poddar, Kanhaiya Lal; Puri, Rishi; Svensson, Lars G; Krishnaswamy, Amar; Tuzcu, E Murat; Kapadia, Samir R

    2015-02-15

    The SAPIEN-XT is a newer generation balloon-expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves. All patients who underwent transfemoral-transcatheter aortic valve replacement using the SAPIEN-XT valve at the Cleveland Clinic were included. Recoil was measured using biplane cine-angiographic image analysis of valve deployment. Acute recoil was defined as [(valve diameter at maximal balloon inflation) - (valve diameter after deflation)]/valve diameter at maximal balloon inflation (reported as percentage). Patients undergoing SAPIEN valve implantation were used as the comparison group. Among the 23 mm valves, the mean (standard deviation-SD) acute recoil was 2.77% (1.14) for the SAPIEN valve as compared to 3.75% (1.52) for the SAPIEN XT valve (P = 0.04). Among the 26 mm valves, the mean (SD) acute recoil was 2.85% (1.4) for the SAPIEN valve as compared to 4.32% (1.63) for the SAPIEN XT valve (P = 0.01). Multivariable linear regression analysis demonstrated significantly greater adjusted recoil in the SAPIEN XT valves as compared to the SAPIEN valves by 1.43% [(95% CI: 0.69-2.17), P < 0.001]. However, the residual peak gradient was less for SAPIEN XT compared to SAPIEN valves [18.86 mm Hg versus 23.53 mm Hg (P = 0.01)]. Additionally, no difference in paravalvular leak was noted between the two valve types (P = 0.78). The SAPIEN XT valves had significantly greater acute recoil after deployment compared to the SAPIEN valves. Implications of this difference in acute recoil on valve performance need to be investigated in future studies. © 2014 Wiley Periodicals, Inc.

  6. Engineering PFLOTRAN for Scalable Performance on Cray XT and IBM BlueGene Architectures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mills, Richard T; Sripathi, Vamsi K; Mahinthakumar, Gnanamanika

    We describe PFLOTRAN - a code for simulation of coupled hydro-thermal-chemical processes in variably saturated, non-isothermal, porous media - and the approaches we have employed to obtain scalable performance on some of the largest scale supercomputers in the world. We present detailed analyses of I/O and solver performance on Jaguar, the Cray XT5 at Oak Ridge National Laboratory, and Intrepid, the IBM BlueGene/P at Argonne National Laboratory, that have guided our choice of algorithms.

  7. Autosomal dominant frontonasal dysplasia (atypical Greig syndrome): Lessons from the Xt mutant mouse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunningham, M.L.; Nunes, M.E.

    1994-09-01

    Greig syndrome is the autosomal dominant association of mild hypertelorism, variable polysyndactyly, and normal intelligence. Several families have been found to have translocations or deletions of 7p13 interrupting the normal expression of GLI3 (a zinc finger, DNA binding, transcription repressor). Recently, a mutation in the mouse homologue of GLI3 was found in the extra-toes mutant mouse (Xt). The phenotypic features of this mouse model include mild hypertelorism, postaxial polydactyly of the forelimbs, preaxial polydactyly of the hindlimbs, and variable tibial hemimelia. The homozygous mutant Xt/Xt have severe frontonasal dysplasia (FND), polysyndactyly of fore-and hindlimbs and invariable tibial hemimelia. We havemore » recently evaluated a child with severe (type D) frontonasal dysplasia, fifth finger camptodactyly, preaxial polydactyly of one foot, and ispilateral tibial hemimelia. His father was born with a bifid nose, broad columnella, broad feet, and a two centimeter leg length discrepancy. The paternal grandmother of the proband is phenotypically normal; however, her fraternal twin died at birth with severe facial anomalies. The paternal great-grandmother of the proband is phenotypically normal however her niece was born with moderate ocular hypertelorism. This pedigree is suggestive of an autosomal dominant form of frontonasal dysplasia with variable expressivity. The phenotypic features of our case more closely resemble the Xt mouse than the previously defined features of Greig syndrome in humans. This suggests that a mutation in GLI3 may be responsible for FND in this family. We are currently using polymorphic dinucleotide repeat markers flanking GLI3 in a attempt to demonstrate linkage in this pedigree. Demonstration of a GLI3 mutation in this family would broaden our view of the spectrum of phenotypes possible in Greig syndrome and could provide insight into genotype/phenotype correlation in FND.« less

  8. Gene expression and localization of two types of AQP5 in Xenopus tropicalis under hydration and dehydration.

    PubMed

    Shibata, Yuki; Sano, Takahiro; Tsuchiya, Nobuhito; Okada, Reiko; Mochida, Hiroshi; Tanaka, Shigeyasu; Suzuki, Masakazu

    2014-07-01

    Two types of aquaporin 5 (AQP5) genes (aqp-xt5a and aqp-xt5b) were identified in the genome of Xenopus tropicalis by synteny comparison and molecular phylogenetic analysis. When the frogs were in water, AQP-xt5a mRNA was expressed in the skin and urinary bladder. The expression of AQP-xt5a mRNA was significantly increased in dehydrated frogs. AQP-xt5b mRNA was also detected in the skin and increased in response to dehydration. Additionally, AQP-xt5b mRNA began to be slightly expressed in the lung and stomach after dehydration. For the pelvic skin of hydrated frogs, immunofluorescence staining localized AQP-xt5a and AQP-xt5b to the cytoplasm of secretory cells of the granular glands and the apical plasma membrane of secretory cells of the small granular glands, respectively. After dehydration, the locations of both AQPs in their respective glands did not change, but AQP-xt5a was visualized in the cytoplasm of secretory cells of the small granular glands. For the urinary bladder, AQP-xt5a was observed in the apical plasma membrane and cytoplasm of a number of granular cells under normal hydration. After dehydration, AQP-xt5a was found in the apical membrane and cytoplasm of most granular cells. Injection of vasotocin into hydrated frogs did not induce these changes in the localization of AQP-xt5a in the small granular glands and urinary bladder, however. The results suggest that AQP-xt5a might be involved in water reabsorption from the urinary bladder during dehydration, whereas AQP-xt5b might play a role in water secretion from the small granular gland. Copyright © 2014 the American Physiological Society.

  9. The neXtProt peptide uniqueness checker: a tool for the proteomics community.

    PubMed

    Schaeffer, Mathieu; Gateau, Alain; Teixeira, Daniel; Michel, Pierre-André; Zahn-Zabal, Monique; Lane, Lydie

    2017-11-01

    The neXtProt peptide uniqueness checker allows scientists to define which peptides can be used to validate the existence of human proteins, i.e. map uniquely versus multiply to human protein sequences taking into account isobaric substitutions, alternative splicing and single amino acid variants. The pepx program is available at https://github.com/calipho-sib/pepx and can be launched from the command line or through a cgi web interface. Indexing requires a sequence file in FASTA format. The peptide uniqueness checker tool is freely available on the web at https://www.nextprot.org/tools/peptide-uniqueness-checker and from the neXtProt API at https://api.nextprot.org/. lydie.lane@sib.swiss. © The Author(s) 2017. Published by Oxford University Press.

  10. Soft x-ray imager (SXI) onboard the NeXT satellite

    NASA Astrophysics Data System (ADS)

    Tsuru, Takeshi Go; Takagi, Shin-Ichiro; Matsumoto, Hironori; Inui, Tatsuya; Ozawa, Midori; Koyama, Katsuji; Tsunemi, Hiroshi; Hayashida, Kiyoshi; Miyata, Emi; Ozawa, Hideki; Touhiguchi, Masakuni; Matsuura, Daisuke; Dotani, Tadayasu; Ozaki, Masanobu; Murakami, Hiroshi; Kohmura, Takayoshi; Kitamoto, Shunji; Awaki, Hisamitsu

    2006-06-01

    We give overview and the current status of the development of the Soft X-ray Imager (SXI) onboard the NeXT satellite. SXI is an X-ray CCD camera placed at the focal plane detector of the Soft X-ray Telescopes for Imaging (SXT-I) onboard NeXT. The pixel size and the format of the CCD is 24 x 24μm (IA) and 2048 x 2048 x 2 (IA+FS). Currently, we have been developing two types of CCD as candidates for SXI, in parallel. The one is front illumination type CCD with moderate thickness of the depletion layer (70 ~ 100μm) as a baseline plan. The other one is the goal plan, in which we develop back illumination type CCD with a thick depletion layer (200 ~ 300μm). For the baseline plan, we successfully developed the proto model 'CCD-NeXT1' with the pixel size of 12μm x 12μm and the CCD size of 24mm x 48mm. The depletion layer of the CCD has reached 75 ~ 85μm. The goal plan is realized by introduction of a new type of CCD 'P-channel CCD', which collects holes in stead of electrons in the common 'N-channel CCD'. By processing a test model of P-channel CCD we have confirmed high quantum efficiency above 10 keV with an equivalent depletion layer of 300μm. A back illumination type of P-channel CCD with a depletion layer of 200μm with aluminum coating for optical blocking has been also successfully developed. We have been also developing a thermo-electric cooler (TEC) with the function of the mechanically support of the CCD wafer without standoff insulators, for the purpose of the reduction of thermal input to the CCD through the standoff insulators. We have been considering the sensor housing and the onboard electronics for the CCD clocking, readout and digital processing of the frame date.

  11. Near-Range Receiver Unit of Next Generation PollyXT Used with Koldeway Aerosol Raman Lidar in Arctic

    NASA Astrophysics Data System (ADS)

    Stachlewska, Iwona S.; Markowicz, Krzysztof M.; Ritter, Christoph; Neuber, Roland; Heese, Birgit; Engelmann, Ronny; Linne, Holger

    2016-06-01

    The Near-range Aerosol Raman lidar (NARLa) receiver unit, that was designed to enhance the detection range of the NeXT generation PollyXT Aerosol-Depolarization-Raman (ADR) lidar of the University of Warsaw, was employed next the Koldeway Aerosol Raman Lidar (KARL) at the AWI-IPEV German-French station in Arctic during Spring 2015. Here we introduce shortly design of both lidars, the scheme of their installation next to each other, and preliminary results of observations aiming at arctic haze investigation by the lidars and the iCAP a set of particle counter and aethalometer installed under a tethered balloon.

  12. 75 FR 13172 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ... internal distributors count and report each server and display device that processes TotalView-ITCH data as a professional TotalView and OpenView user. Some firms report upwards of 500 devices, while other.... Nasdaq has offered similar enterprise licenses for professional and non-professional usage of TotalView...

  13. 77 FR 21125 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-09

    ... allocates market data fees among Subscribers based on the data elements consumed, including top-of-book,\\3... apply to any Subscriber that accesses any data elements included in the TotalView entitlement, including the TotalView, OpenView, or Level 2 data elements. Professional Subscribers that access Depth-of-Book...

  14. Application of Strep-Tactin XT for affinity purification of Twin-Strep-tagged CB2, a G protein-coupled cannabinoid receptor

    PubMed Central

    Yeliseev, Alexei; Zoubak, Lioudmila; Schmidt, Thomas G.M.

    2017-01-01

    Human cannabinoid receptor CB2 belongs to the class A of G protein-coupled receptor (GPCR). High resolution structural studies of CB2 require milligram quantities of purified, structurally intact protein. Here we describe an efficient protocol for purification of this protein using the Twin-Strep-tag/Strep-Tactin XT system. To improve the affinity of interaction of the recombinant CB2 with the resin, the double repeat of the Strep-tag was attached either to the N- or C-terminus of CB2 via a short linker. The CB2 was isolated at high purity from dilute solutions containing high concentrations of detergents, glycerol and salts, by capturing onto the Strep-Tactin XT resin, and was eluted from the resin under mild conditions upon addition of biotin. Surface plasmon resonance studies performed demonstrate the high affinity of interaction between the Twin-Strep-tag fused to the CB2 and Strep-Tactin XT with an estimated Kd in the low nanomolar range. The affinity of binding did not vary significantly in response to the position of the tag at either N- or C-termini of the fusion. The variation in the length of the linker between the double repeats of the Strep-tag from 6 to 12 amino acid residues did not significantly affect the binding. The novel purification protocol reported here enables efficient isolation of a recombinant GPCR expressed at low titers in host cells. This procedure is suitable for preparation of milligram quantities of stable isotope-labelled receptor for high-resolution NMR studies. PMID:27867058

  15. Attitude control system of the Delfi-n3Xt satellite

    NASA Astrophysics Data System (ADS)

    Reijneveld, J.; Choukroun, D.

    2013-12-01

    This work is concerned with the development of the attitude control algorithms that will be implemented on board of the Delfi-n3xt nanosatellite, which is to be launched in 2013. One of the mission objectives is to demonstrate Sun pointing and three axis stabilization. The attitude control modes and the associated algorithms are described. The control authority is shared between three body-mounted magnetorquers (MTQ) and three orthogonal reaction wheels. The attitude information is retrieved from Sun vector measurements, Earth magnetic field measurements, and gyro measurements. The design of the control is achieved as a trade between simplicity and performance. Stabilization and Sun pointing are achieved via the successive application of the classical Bdot control law and a quaternion feedback control. For the purpose of Sun pointing, a simple quaternion estimation scheme is implemented based on geometric arguments, where the need for a costly optimal filtering algorithm is alleviated, and a single line of sight (LoS) measurement is required - here the Sun vector. Beyond the three-axis Sun pointing mode, spinning Sun pointing modes are also described and used as demonstration modes. The three-axis Sun pointing mode requires reaction wheels and magnetic control while the spinning control modes are implemented with magnetic control only. In addition, a simple scheme for angular rates estimation using Sun vector and Earth magnetic measurements is tested in the case of gyro failures. The various control modes performances are illustrated via extensive simulations over several orbits time spans. The simulated models of the dynamical space environment, of the attitude hardware, and the onboard controller logic are using realistic assumptions. All control modes satisfy the minimal Sun pointing requirements allowed for power generation.

  16. Collective Framework and Performance Optimizations to Open MPI for Cray XT Platforms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ladd, Joshua S; Gorentla Venkata, Manjunath; Shamis, Pavel

    2011-01-01

    The performance and scalability of collective operations plays a key role in the performance and scalability of many scientific applications. Within the Open MPI code base we have developed a general purpose hierarchical collective operations framework called Cheetah, and applied it at large scale on the Oak Ridge Leadership Computing Facility's Jaguar (OLCF) platform, obtaining better performance and scalability than the native MPI implementation. This paper discuss Cheetah's design and implementation, and optimizations to the framework for Cray XT 5 platforms. Our results show that the Cheetah's Broadcast and Barrier perform better than the native MPI implementation. For medium data,more » the Cheetah's Broadcast outperforms the native MPI implementation by 93% for 49,152 processes problem size. For small and large data, it out performs the native MPI implementation by 10% and 9%, respectively, at 24,576 processes problem size. The Cheetah's Barrier performs 10% better than the native MPI implementation for 12,288 processes problem size.« less

  17. 5nsec Dead time multichannel scaling system for Mössbauer spectrometer

    NASA Astrophysics Data System (ADS)

    Verrastro, C.; Trombetta, G.; Pita, A.; Saragovi, C.; Duhalde, S.

    1991-11-01

    A PC programmable and fast multichannel scaling module has been designed to use a commercial Mössbauer spectrometer. This module is based on a 10 single chip 8 bits microcomputer (MC6805) and on a 35 fast ALU, which allows a high performance and low cost system. The module can operate in a stand-alone mode. Data analysis are performed in real time display, on XT/AT IBM PC or compatibles. The channels are ranged between 256 and 4096, the maximum number of counts is 232-1 per channel, the dwell time is 3 μsec and the dead time between channels is 5 nsec. A friendly software display the real time spectrum and offers menues with different options at each state.

  18. Onboard data-processing architecture of the soft X-ray imager (SXI) on NeXT satellite

    NASA Astrophysics Data System (ADS)

    Ozaki, Masanobu; Dotani, Tadayasu; Tsunemi, Hiroshi; Hayashida, Kiyoshi; Tsuru, Takeshi G.

    2004-09-01

    NeXT is the X-ray satellite proposed for the next Japanese space science mission. While the satellite total mass and the launching vehicle are similar to the prior satellite Astro-E2, the sensitivity is much improved; it requires all the components to be lighter and faster than previous architecture. This paper shows the data processing architecture of the X-ray CCD camera system SXI (Soft X-ray Imager), which is the top half of the WXI (Wide-band X-ray Imager) of the sensitivity in 0.2-80keV. The system is basically a variation of Astro-E2 XIS, but event extraction speed is much faster than it to fulfill the requirements coming from the large effective area and fast exposure period. At the same time, data transfer lines between components are redesigned in order to reduce the number and mass of the wire harnesses that limit the flexibility of the component distribution.

  19. Apple founder targets healthcare as NeXT market. Interview by Carolyn Dunbar and Michael L. Laughlin.

    PubMed

    Jobs, S

    1992-12-01

    Cofounder and former chairman of the board of Apple Computer Steven Jobs looks beyond the 1980s image of a petulant, embittered young man, fighting with all who failed to share his vision, and many who did. Today, as a founder, president and chairman of NeXT, Inc., he looks to more high-minded applications of his computer genius.

  20. Computing anticipatory systems with incursion and hyperincursion

    NASA Astrophysics Data System (ADS)

    Dubois, Daniel M.

    1998-07-01

    An anticipatory system is a system which contains a model of itself and/or of its environment in view of computing its present state as a function of the prediction of the model. With the concepts of incursion and hyperincursion, anticipatory discrete systems can be modelled, simulated and controlled. By definition an incursion, an inclusive or implicit recursion, can be written as: x(t+1)=F[…,x(t-1),x(t),x(t+1),…] where the value of a variable x(t+1) at time t+1 is a function of this variable at past, present and future times. This is an extension of recursion. Hyperincursion is an incursion with multiple solutions. For example, chaos in the Pearl-Verhulst map model: x(t+1)=a.x(t).[1-x(t)] is controlled by the following anticipatory incursive model: x(t+1)=a.x(t).[1-x(t+1)] which corresponds to the differential anticipatory equation: dx(t)/dt=a.x(t).[1-x(t+1)]-x(t). The main part of this paper deals with the discretisation of differential equation systems of linear and non-linear oscillators. The non-linear oscillator is based on the Lotka-Volterra equations model. The discretisation is made by incursion. The incursive discrete equation system gives the same stability condition than the original differential equations without numerical instabilities. The linearisation of the incursive discrete non-linear Lotka-Volterra equation system gives rise to the classical harmonic oscillator. The incursive discretisation of the linear oscillator is similar to define backward and forward discrete derivatives. A generalized complex derivative is then considered and applied to the harmonic oscillator. Non-locality seems to be a property of anticipatory systems. With some mathematical assumption, the Schrödinger quantum equation is derived for a particle in a uniform potential. Finally an hyperincursive system is given in the case of a neural stack memory.

  1. Standardized methodology for transfemoral transcatheter aortic valve replacement with the Edwards Sapien XT valve under fluoroscopy guidance.

    PubMed

    Kasel, Albert M; Shivaraju, Anupama; Schneider, Stephan; Krapf, Stephan; Oertel, Frank; Burgdorf, Christof; Ott, Ilka; Sumer, Christian; Kastrati, Adnan; von Scheidt, Wolfgang; Thilo, Christian

    2014-09-01

    To provide a simplified, standardized methodology for a successful transfemoral transcatheter aortic valve replacement (TAVR) procedure with the Sapien XT valve in patients with severe aortic stenosis (AS). TAVR is currently reserved for patients with severe, symptomatic AS who are inoperable or at high operative risk. In many institutions, TAVR is performed under general anesthesia with intubation or with conscious sedation. In addition, many institutions still use transesophageal echo (TEE) during the procedure for aortic root angulations and positioning of the valve prior to implantation. Methods. We enrolled 100 consecutive patients (mean age, 80 ± 7 years; range, 50-94 years; female n=59) with severe symptomatic AS. Annulus measurements were based on computed tomography angiograms. All patients underwent fluoroscopy-guided transfemoral TAVR with little to no sedation and without simultaneous TEE. TAVR was predominantly performed with the use of local and central analgesics; only 36% of our cohort received conscious sedation. Procedural success of TAVR was 99%. Transthoracic echocardiography before discharge excluded aortic regurgitation (AR) >2 in all patients (AR >1; n=6). In-hospital stroke rate was 6%. The vessel closure system was successfully employed in 96%. Major vascular complication rate was 1%. The 30-day mortality was 2%. Fluoroscopy-guided TAVR with the use of just analgesics with or without conscious sedation is safe and effective, and this potentially enables a more time-effective and cost-effective procedure. This paper provides simplified, stepwise guidance on how to perform transfemoral TAVR with the Sapien XT valve.

  2. neXtProt: organizing protein knowledge in the context of human proteome projects.

    PubMed

    Gaudet, Pascale; Argoud-Puy, Ghislaine; Cusin, Isabelle; Duek, Paula; Evalet, Olivier; Gateau, Alain; Gleizes, Anne; Pereira, Mario; Zahn-Zabal, Monique; Zwahlen, Catherine; Bairoch, Amos; Lane, Lydie

    2013-01-04

    About 5000 (25%) of the ~20400 human protein-coding genes currently lack any experimental evidence at the protein level. For many others, there is only little information relative to their abundance, distribution, subcellular localization, interactions, or cellular functions. The aim of the HUPO Human Proteome Project (HPP, www.thehpp.org ) is to collect this information for every human protein. HPP is based on three major pillars: mass spectrometry (MS), antibody/affinity capture reagents (Ab), and bioinformatics-driven knowledge base (KB). To meet this objective, the Chromosome-Centric Human Proteome Project (C-HPP) proposes to build this catalog chromosome-by-chromosome ( www.c-hpp.org ) by focusing primarily on proteins that currently lack MS evidence or Ab detection. These are termed "missing proteins" by the HPP consortium. The lack of observation of a protein can be due to various factors including incorrect and incomplete gene annotation, low or restricted expression, or instability. neXtProt ( www.nextprot.org ) is a new web-based knowledge platform specific for human proteins that aims to complement UniProtKB/Swiss-Prot ( www.uniprot.org ) with detailed information obtained from carefully selected high-throughput experiments on genomic variation, post-translational modifications, as well as protein expression in tissues and cells. This article describes how neXtProt contributes to prioritize C-HPP efforts and integrates C-HPP results with other research efforts to create a complete human proteome catalog.

  3. New superfield extension of Boussinesq and its (x,t) interchanged equation from odd Poisson bracket

    NASA Astrophysics Data System (ADS)

    Palit, S.; Chowdhury, A. Roy

    1995-08-01

    A new superfield extension of the Boussinesq equation and its corresponding (x,t) interchanged variant are deduced from the odd Poisson-bracket-formalism, which is similar to the antibracket of Batalin and Vilkovisky. In the former case we obtain the equation deduced by Figueroa-O'Farrill et al from a different approach. In each case we have deduced the bi-Hamiltonian structure and some basic symmetries associated with them.

  4. Hard x-ray imager for the NeXT mission

    NASA Astrophysics Data System (ADS)

    Nakazawa, Kazuhiro; Fukazawa, Yasushi; Kamae, Tuneyoshi; Kataoka, Jun; Kokubun, Motohide; Makishima, Kazuo; Mizuno, Tsunefumi; Murakami, Toshio; Nomachi, Masaharu; Tajima, Hiroyasu; Takahashi, Tadayuki; Tashiro, Makoto; Tamagawa, Toru; Terada, Yukikatsu; Watanabe, Shin; Yamaoka, Kazutaka; Yonetoku, Daisuke

    2006-06-01

    The hard X-ray imager (HXI) is the primary detector of the NeXT mission, proposed to explore high-energy non-thermal phenomena in the universe. Combined with a novel hard X-ray mirror optics, the HXI is designed to provide better than arc-minutes imaging capability with 1 keV level spectroscopy, and more than 30 times higher sensitivity compared with any existing hard X-ray instruments. The base-line design of the HXI is improving to secure high sensitivity. The key is to reduce the detector background as far as possible. Based on the experience of the Suzaku satellite launched in July 2005, the current design has a well-type tight active shield and multi layered, multi material imaging detector made of Si and CdTe. Technology has been under development for a few years so that we have reached the level where a basic detector performance is satisfied. Design tuning to further improve the sensitivity and reliability is on-going.

  5. Physical-Mechanical Properties of a Fiber-Reinforced Composite Based on an ELUR-P Carbon Tape and XT-118 Binder

    NASA Astrophysics Data System (ADS)

    Paimushin, V. N.; Kholmogorov, S. A.

    2018-03-01

    A series of tests to identify the physical-mechanical properties of a unidirectional carbon-fiber-reinforced composite based on an ELUR-P carbon fibers and an XT-118 epoxy binder were performed. The form of the stress-strain diagrams of specimens loaded in tension in the longitudinal, transverse, and ±45° directions and in compression in the longitudinal and ±45° directions were examined. Tensile diagrams were also determined for the XT-118 binder alone. The relation between the tangential shear modulus and shear strains of the composite was highly nonlinear from the very beginning of loading and depended on the loading type. Such a nonlinear response of the carbon-fiber-reinforced composite in shear cannot be the result of plastic deformation of binder, but can be explained only by structural changes caused by the inner buckling instability of the composite at micro- and mesolevels..

  6. Application of Strep-Tactin XT for affinity purification of Twin-Strep-tagged CB2, a G protein-coupled cannabinoid receptor.

    PubMed

    Yeliseev, Alexei; Zoubak, Lioudmila; Schmidt, Thomas G M

    2017-03-01

    Human cannabinoid receptor CB 2 belongs to the class A of G protein-coupled receptor (GPCR). CB 2 is predominantly expressed in membranes of cells of immune origin and is implicated in regulation of metabolic pathways of inflammation, neurodegenerative disorders and pain sensing. High resolution structural studies of CB 2 require milligram quantities of purified, structurally intact protein. While we previously reported on the methodology for expression of the recombinant CB 2 and its stabilization in a functional state, here we describe an efficient protocol for purification of this protein using the Twin-Strep-tag/Strep-Tactin XT system. To improve the affinity of interaction of the recombinant CB 2 with the resin, the double repeat of the Strep-tag (a sequence of eight amino acids WSHPQFEK), named the Twin-Strep-tag was attached either to the N- or C-terminus of CB 2 via a short linker, and the recombinant protein was expressed in cytoplasmic membranes of E. coli as a fusion with the N-terminal maltose binding protein (MBP). The CB 2 was isolated at high purity from dilute solutions containing high concentrations of detergents, glycerol and salts, by capturing onto the Strep-Tactin XT resin, and was eluted from the resin under mild conditions upon addition of biotin. Surface plasmon resonance studies performed on the purified protein demonstrate the high affinity of interaction between the Twin-Strep-tag fused to the CB 2 and Strep-Tactin XT with an estimated Kd in the low nanomolar range. The affinity of binding did not vary significantly in response to the position of the tag at either N- or C-termini of the fusion. The binding capacity of the resin was several-fold higher for the tag located at the N-terminus of the protein as opposed to the C-terminus- or middle of the fusion. The variation in the length of the linker between the double repeats of the Strep-tag from 6 to 12 amino acid residues did not significantly affect the binding. The novel purification

  7. Resource-Efficient, Hierarchical Auto-Tuning of a Hybrid Lattice Boltzmann Computation on the Cray XT4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Computational Research Division, Lawrence Berkeley National Laboratory; NERSC, Lawrence Berkeley National Laboratory; Computer Science Department, University of California, Berkeley

    2009-05-04

    We apply auto-tuning to a hybrid MPI-pthreads lattice Boltzmann computation running on the Cray XT4 at National Energy Research Scientific Computing Center (NERSC). Previous work showed that multicore-specific auto-tuning can improve the performance of lattice Boltzmann magnetohydrodynamics (LBMHD) by a factor of 4x when running on dual- and quad-core Opteron dual-socket SMPs. We extend these studies to the distributed memory arena via a hybrid MPI/pthreads implementation. In addition to conventional auto-tuning at the local SMP node, we tune at the message-passing level to determine the optimal aspect ratio as well as the correct balance between MPI tasks and threads permore » MPI task. Our study presents a detailed performance analysis when moving along an isocurve of constant hardware usage: fixed total memory, total cores, and total nodes. Overall, our work points to approaches for improving intra- and inter-node efficiency on large-scale multicore systems for demanding scientific applications.« less

  8. The Spider Center Wide File System; From Concept to Reality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shipman, Galen M; Dillow, David A; Oral, H Sarp

    2009-01-01

    The Leadership Computing Facility (LCF) at Oak Ridge National Laboratory (ORNL) has a diverse portfolio of computational resources ranging from a petascale XT4/XT5 simulation system (Jaguar) to numerous other systems supporting development, visualization, and data analytics. In order to support vastly different I/O needs of these systems Spider, a Lustre-based center wide file system was designed and deployed to provide over 240 GB/s of aggregate throughput with over 10 Petabytes of formatted capacity. A multi-stage InfiniBand network, dubbed as Scalable I/O Network (SION), with over 889 GB/s of bisectional bandwidth was deployed as part of Spider to provide connectivity tomore » our simulation, development, visualization, and other platforms. To our knowledge, while writing this paper, Spider is the largest and fastest POSIX-compliant parallel file system in production. This paper will detail the overall architecture of the Spider system, challenges in deploying and initial testings of a file system of this scale, and novel solutions to these challenges which offer key insights into file system design in the future.« less

  9. Comparison of the BD MAX MRSA XT to the Cepheid™ Xpert® MRSA assay for the molecular detection of methicillin-resistant Staphylococcus aureus from nasal swabs.

    PubMed

    Mehta, Sanjay R; Estrada, Jasmine; Ybarra, Juan; Fierer, Joshua

    2017-04-01

    Variation in MRSA genotypes may affect the sensitivity of molecular assays to detect this organism. We compared 2 commonly used screening assays, the Cepheid™ Xpert® MRSA and the BD MAX™ MRSA XT on consecutively obtained nasal swabs from 479 subjects. Specimens giving discordant results were subjected to additional microbiologic and molecular testing. Six hundred forty-two (97.6%) of the 658 test results were concordant. Of the 16 discordant results from 12 subjects, additional results suggested that 9 (60%) of the 15 MRSA XT assays were likely correct, and 6 (40%) of the 15 Xpert® assays were likely correct. One discordant result could not be resolved. A mecA dropout and novel mec right-extremity junction (MREJ) sites led to false-positive and negative results by Xpert®. While both assays performed well, continued vigilance is needed to monitor for Staphylococcus aureus with novel MREJ sites, mecA dropouts, and mecC, leading to inaccurate results in screening assays. Published by Elsevier Inc.

  10. System Accuracy Evaluation of Four Systems for Self-Monitoring of Blood Glucose Following ISO 15197 Using a Glucose Oxidase and a Hexokinase-Based Comparison Method.

    PubMed

    Link, Manuela; Schmid, Christina; Pleus, Stefan; Baumstark, Annette; Rittmeyer, Delia; Haug, Cornelia; Freckmann, Guido

    2015-04-14

    The standard ISO (International Organization for Standardization) 15197 is widely accepted for the accuracy evaluation of systems for self-monitoring of blood glucose (SMBG). Accuracy evaluation was performed for 4 SMBG systems (Accu-Chek Aviva, ContourXT, GlucoCheck XL, GlucoMen LX PLUS) with 3 test strip lots each. To investigate a possible impact of the comparison method on system accuracy data, 2 different established methods were used. The evaluation was performed in a standardized manner following test procedures described in ISO 15197:2003 (section 7.3). System accuracy was assessed by applying ISO 15197:2003 and in addition ISO 15197:2013 criteria (section 6.3.3). For each system, comparison measurements were performed with a glucose oxidase (YSI 2300 STAT Plus glucose analyzer) and a hexokinase (cobas c111) method. All 4 systems fulfilled the accuracy requirements of ISO 15197:2003 with the tested lots. More stringent accuracy criteria of ISO 15197:2013 were fulfilled by 3 systems (Accu-Chek Aviva, ContourXT, GlucoMen LX PLUS) when compared to the manufacturer's comparison method and by 2 systems (Accu-Chek Aviva, ContourXT) when compared to the alternative comparison method. All systems showed lot-to-lot variability to a certain degree; 2 systems (Accu-Chek Aviva, ContourXT), however, showed only minimal differences in relative bias between the 3 evaluated lots. In this study, all 4 systems complied with the evaluated test strip lots with accuracy criteria of ISO 15197:2003. Applying ISO 15197:2013 accuracy limits, differences in the accuracy of the tested systems were observed, also demonstrating that the applied comparison method/system and the lot-to-lot variability can have a decisive influence on accuracy data obtained for a SMBG system. © 2015 Diabetes Technology Society.

  11. London penetration depth measurements in Ba (Fe 1-xT x) 2As 2(T=Co,Ni,Ru,Rh,Pd,Pt,Co+Cu) superconductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, Ryan T.

    2011-01-01

    The London penetration depth has been measured in various doping levels of single crystals of Ba(Fe 1-xT x) 2As 2 (T=Co,Ni,Ru,Rh,Pd,Pt,Co+Cu) superconductors by utilizing a tunnel diode resonator (TDR) apparatus. All in-plane penetration depth measurements exhibit a power law temperature dependence of the form Δλ ab(T) = CT n, indicating the existence of low-temperature, normal state quasiparticles all the way down to the lowest measured temperature, which was typically 500 mK. Several different doping concentrations from the Ba(Fe 1-xT x) 2As 2 (T=Co,Ni) systems have been measured and the doping dependence of the power law exponent, n, is compared tomore » results from measurements of thermal conductivity and specific heat. In addition, a novel method has been developed to allow for the measurement of the zero temperature value of the in-plane penetration depth, λ ab(0), by using TDR frequency shifts. By using this technique, the doping dependence of λ ab(0) has been measured in the Ba(Fe 1-xCo x) 2As 2 series, which has allowed also for the construction of the doping-dependent superfluid phase stiffness, ρ s(T) = [λ(0)/λ(T)] 2. By studying the effects of disorder on these superconductors using heavy ion irradiation, it has been determined that the observed power law temperature dependence likely arises from pair-breaking impurity scattering contributions, which is consistent with the proposed s±-wave symmetry of the superconducting gap in the dirty scattering limit. This hypothesis is supported by the measurement of an exponential temperature dependence of the penetration depth in the intrinsically clean LiFeAs, indicative of a nodeless superconducting gap.« less

  12. Using Noldus Observer XT for research on deaf signers learning to read: an innovative methodology.

    PubMed

    Ducharme, Daphne A; Arcand, Isabelle

    2009-08-01

    Despite years of research on the reading problems of deaf students, we still do not know how deaf signers who read well actually crack the code of print. How connections are made between sign language and written language is still an open question. In this article, we show how the Noldus Observer XT software can be used to conduct an in-depth analysis of the online behavior of deaf readers. First, we examine factors that may have an impact on reading behavior. Then, we describe how we videotaped teachers with their deaf student signers of langue des signes québécoise during a reading task, how we conducted a recall activity to better understand the students' reading behavior, and how we used this innovative software to analyze the taped footage. Finally, we discuss the contribution this type of research can have on the future reading behavior of deaf students.

  13. Laser capture microdissection: Arcturus(XT) infrared capture and UV cutting methods.

    PubMed

    Gallagher, Rosa I; Blakely, Steven R; Liotta, Lance A; Espina, Virginia

    2012-01-01

    Laser capture microdissection (LCM) is a technique that allows the precise procurement of enriched cell populations from a heterogeneous tissue under direct microscopic visualization. LCM can be used to harvest the cells of interest directly or can be used to isolate specific cells by ablating the unwanted cells, resulting in histologically enriched cell populations. The fundamental components of laser microdissection technology are (a) visualization of the cells of interest via microscopy, (b) transfer of laser energy to a thermolabile polymer with either the formation of a polymer-cell composite (capture method) or transfer of laser energy via an ultraviolet laser to photovolatize a region of tissue (cutting method), and (c) removal of cells of interest from the heterogeneous tissue section. Laser energy supplied by LCM instruments can be infrared (810 nm) or ultraviolet (355 nm). Infrared lasers melt thermolabile polymers for cell capture, whereas ultraviolet lasers ablate cells for either removal of unwanted cells or excision of a defined area of cells. LCM technology is applicable to an array of applications including mass spectrometry, DNA genotyping and loss-of-heterozygosity analysis, RNA transcript profiling, cDNA library generation, proteomics discovery, and signal kinase pathway profiling. This chapter describes the unique features of the Arcturus(XT) laser capture microdissection instrument, which incorporates both infrared capture and ultraviolet cutting technology in one instrument, using a proteomic downstream assay as a model.

  14. Accuracy Assessment for the Auxillary Tracking System

    DTIC Science & Technology

    1991-09-01

    Auxiliary Tracking System (ATS), paper prepared for evaluation of ATS design review, 28 June, 1990. Anton , H., and Rorres, C., Elementary Linear Algebra with...are linearized around the trial value (XT6, YT,, Zro), shown in Equation 3.16, where 10 means evaluated at point "o". The OR1aI * YaT- I T.) ZR (ZT...3.16) partial derivatives are listed in Equations 3.17 through 3.19. 8XR.[ o 7.-OR1 [ .XT-XL (3.17) aOR., ZTo-Z 1 (3.19) aZTIo R. The linearized

  15. Corrosion behavior of aluminum-alumina composites in aerated 3.5 percent chloride solution

    NASA Astrophysics Data System (ADS)

    Acevedo Hurtado, Paul Omar

    Aluminum based metal matrix composites are finding many applications in engineering. Of these Al-Al2O3 composites appear to have promise in a number of defense applications because of their mechanical properties. However, their corrosion behavior remains suspect, especially in marine environments. While efforts are being made to improve the corrosion resistance of Al-Al2O3 composites, the mechanism of corrosion is not well known. In this study, the corrosion behavior of powder metallurgy processed Al-Cu alloy reinforced with 10, 15, 20 and 25 vol. % Al2O3 particles (XT 1129, XT 2009, XT 2048, XT 2031) was evaluated in aerated 3.5% NaCl solution using microstructural and electrochemical measurements. AA1100-O and AA2024T4 monolithic alloys were also studied for comparison purposes. The composites and unreinforced alloys were subjected to potentiodynamic polarization and Electrochemical Impedance Spectroscopy (EIS) testing. Addition of 25 vol. % Al2O 3 to the base alloys was found to increase its corrosion resistance considerably. Microstructural studies revealed the presence of intermetallic Al2Cu particles in these composites that appeared to play an important role in the observations. Pitting potential for these composites was near corrosion potential values, and repassivation potential was below the corresponding corrosion potential, indicating that these materials begin to corrode spontaneously as soon as they come in contact with the 3.5 % NaCl solution. EIS measurements indicate the occurrence of adsorption/diffusion phenomena at the interface of the composites which ultimately initiate localized or pitting corrosion. Polarization resistance values were extracted from the EIS data for all the materials tested. Electrically equivalent circuits are proposed to describe and substantiate the corrosive processes occurring in these Al-Al2O 3 composite materials.

  16. Microcomputer-Based Genetics Office Database System

    PubMed Central

    Cutts, James H.; Mitchell, Joyce A.

    1985-01-01

    A database management system (Genetics Office Automation System, GOAS) has been developed for the Medical Genetics Unit of the University of Missouri. The system, which records patients' visits to the Unit's genetic and prenatal clinics, has been implemented on an IBM PC/XT microcomputer. A description of the system, the reasons for implementation, its databases, and uses are presented.

  17. Effect of moisture on dental enamel in the interaction of two orthodontic bonding systems.

    PubMed

    Bertoz, André Pinheiro de Magalhães; de Oliveira, Derly Tescaro Narcizo; Gimenez, Carla Maria Melleiro; Briso, André Luiz Fraga; Bertoz, Francisco Antonio; Santos, Eduardo César Almada

    2013-01-01

    The purpose of this study was to assess by means of scanning electron microscopy (SEM) the remaining adhesive interface after debonding orthodontic attachments bonded to bovine teeth with the use of hydrophilic and hydrophobic primers under different dental substrate moisture conditions. Twenty mandibular incisors were divided into four groups (n = 5). In Group I, bracket bonding was performed with Transbond MIP hydrophilic primer and Transbond XT adhesive paste applied to moist substrate, and in Group II a bonding system comprising Transbond XT hydrophobic primer and adhesive paste was applied to moist substrate. Brackets were bonded to the specimens in Groups III and IV using the same adhesive systems, but on dry dental enamel. The images were qualitatively assessed by SEM. The absence of moisture in etched enamel enabled better interaction between bonding materials and the adamantine structure. The hydrophobic primer achieved the worst micromechanical interlocking results when applied to a moist dental structure, whereas the hydrophilic system proved versatile, yielding acceptable results in moist conditions and excellent interaction in the absence of contamination. The authors assert that the best condition for the application of primers to dental enamel occurs in the absence of moisture.

  18. Definition of propulsion system for V/STOL research and technology aircraft

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Wind tunnel test support, aircraft contractor support, a propulsion system computer card deck, preliminary design studies, and propulsion system development plan are reported. The Propulsion system consists of two lift/cruise turbofan engines, one turboshaft engine and one lift fan connected together with shafting into a combiner gearbox. Distortion parameter levels from 40 x 80 test data were within the established XT701-AD-700 limits. The three engine-three fan system card deck calculates either vertical or conventional flight performance, installed or uninstalled. Design study results for XT701 engine modifications, bevel gear cross shaft location, fixed and tilt fan frames and propulsion system controls are described. Optional water-alcohol injection increased total net thrust 10.3% on a 90 F day. Engines have sufficient turbine life for 500 hours of the RTA duty cycle.

  19. 75 FR 5821 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-04

    ... Exchange proposes to clarify Nasdaq Rule 7023 to make clear that Historical ModelView information will be available via NasdaqTrader.com and that references to the Historical TotalView data product will be deleted... text of the proposed rule change is available from Nasdaq's Web site at http://nasdaq.cchwallstreet.com...

  20. Implementation of the Automated Numerical Model Performance Metrics System

    DTIC Science & Technology

    2011-09-26

    question. As of this writing, the DSRC IBM AIX machines DaVinci and Pascal, and the Cray XT Einstein all use the PBS batch queuing system for...3.3). 12 Appendix A – General Automation System This system provides general purpose tools and a general way to automatically run

  1. Temperature-dependent elasticity of Pb [(Mg0.33Nb0.67 ) 1 -xT ix ] O3

    NASA Astrophysics Data System (ADS)

    Tennakoon, Sumudu; Gladden, Joseph; Mookherjee, Mainak; Besara, Tiglet; Siegrist, Theo

    2017-10-01

    Relaxor ferroelectric materials, such as Pb [(Mg0.33Nb0.67 ) 1 -xT ix ] O3 (PMN-PT) with generic stoichiometry, undergo a ferroelectric-to-paraelectric phase transition as a function of temperature. The exact transition characterized by Curie temperature (Tc) varies as a function of chemistry (x ), i.e., the concentration of Ti. In this study, we investigated the structural phase transition by exploring the temperature dependence of the single-crystal elastic properties of Pb [(Mg0.33Nb0.67 ) 0.7T i0.3 ] O3 , i.e., x ≈0.3 . We used resonant ultrasound spectroscopy to determine the elasticity at elevated temperatures, from which Tc=398 ±5 K for PMN-PT (x ≈0.3 ) was determined. We report the full elastic constant tensor (Ci j={ C11,C12,C44 }), acoustic attenuation (Q-1), longitudinal (VP) and shear (VS) sound velocities, and elastic anisotropy of PMN-PT as a function of temperature for 400 Tc the material first stiffens and reaches maxima in the vicinity of the Burns temperature (Tb˜673 K ), followed by a more typical gradual softening of the elastic constants. Similar temperature-dependent anomalies are also observed with anisotropy and Q-1, with minima in the vicinity of Tb. We used the temperature dependence of Ci j, Q-1, VP,VS , and anisotropy to infer the evolution of polar nanoregions as the material evolved from T >Tc .

  2. Valve-in-valve using an Edwards Sapien XT into a JenaValve in a patient with a low originating left coronary artery and a heavily calcified aorta.

    PubMed

    Fujita, Buntaro; Scholtz, Smita; Ensminger, Stephan

    2016-04-01

    Coronary obstruction during transcatheter aortic valve implantation is a potentially life-threatening complication. Most of the widely used transcatheter heart valves require a certain distance between the basal aortic annular plane and the origins of the coronary arteries. We report the case of a successful valve-in-valve procedure with an Edwards SAPIEN XT valve into a JenaValve as a bail-out procedure in a patient with a low originating left coronary artery and a heavily calcified aorta. © 2015 Wiley Periodicals, Inc.

  3. System Engineering Concept Demonstration, Interface Standards Studies. Volume 4

    DTIC Science & Technology

    1992-12-01

    Xerox’s Palo Alto Research Center (PARC) 25 begat the Xerox Star; Steve Jobs visited PARC, saw the Star, went back to Apple, and begat the Mac. But...Author of Adobe Systems, PostScript Language Program Design, has left Adobe to join Steve Jobs ’ NeXT, Inc. Reid worked for Adobe Systems for four and a

  4. Post retention and post/core shear bond strength of four post systems.

    PubMed

    Stockton, L W; Williams, P T; Clarke, C T

    2000-01-01

    As clinicians we continue to search for a post system which will give us maximum retention while maximizing resistance to root fracture. The introduction of several new post systems, with claims of high retentive and resistance to root fracture values, require that independent studies be performed to evaluate these claims. This study tested the tensile and shear dislodgment forces of four post designs that were luted into roots 10 mm apical of the CEJ. The Para Post Plus (P1) is a parallel-sided, passive design; the Para Post XT (P2) is a combination active/passive design; the Flexi-Post (F1) and the Flexi-Flange (F2) are active post designs. All systems tested were stainless steel. This study compared the test results of the four post designs for tensile and shear dislodgment. All mounted samples were loaded in tension until failure occurred. The tensile load was applied parallel to the long axis of the root, while the shear load was applied at 450 to the long axis of the root. The Flexi-Post (F1) was significantly different from the other three in the tensile test, however, the Para Post XT (P2) was significantly different to the other three in the shear test and had a better probability for survival in the Kaplan-Meier survival function test. Based on the results of this study, our recommendation is for the Para Post XT (P2).

  5. Ectodermal Influx and Cell Hypertrophy Provide Early Growth for All Murine Mammary Rudiments, and Are Differentially Regulated among Them by Gli3

    PubMed Central

    Lee, May Yin; Racine, Victor; Jagadpramana, Peter; Sun, Li; Yu, Weimiao; Du, Tiehua; Spencer-Dene, Bradley; Rubin, Nicole; Le, Lendy; Ndiaye, Delphine; Bellusci, Saverio; Kratochwil, Klaus; Veltmaat, Jacqueline M.

    2011-01-01

    Mammary gland development starts in utero with one or several pairs of mammary rudiments (MRs) budding from the surface ectodermal component of the mammalian embryonic skin. Mice develop five pairs, numbered MR1 to MR5 from pectoral to inguinal position. We have previously shown that Gli3Xt-J/Xt-J mutant embryos, which lack the transcription factor Gli3, do not form MR3 and MR5. We show here that two days after the MRs emerge, Gli3Xt-J/Xt-J MR1 is 20% smaller, and Gli3Xt-J/Xt-J MR2 and MR4 are 50% smaller than their wild type (wt) counterparts. Moreover, while wt MRs sink into the underlying dermis, Gli3Xt-J/Xt-J MR4 and MR2 protrude outwardly, to different extents. To understand why each of these five pairs of functionally identical organs has its own, distinct response to the absence of Gli3, we determined which cellular mechanisms regulate growth of the individual MRs, and whether and how Gli3 regulates these mechanisms. We found a 5.5 to 10.7-fold lower cell proliferation rate in wt MRs compared to their adjacent surface ectoderm, indicating that MRs do not emerge or grow via locally enhanced cell proliferation. Cell-tracing experiments showed that surface ectodermal cells are recruited toward the positions where MRs emerge, and contribute to MR growth during at least two days. During the second day of MR development, peripheral cells within the MRs undergo hypertrophy, which also contributes to MR growth. Limited apoptotic cell death counterbalances MR growth. The relative contribution of each of these processes varies among the five MRs. Furthermore, each of these processes is impaired in the absence of Gli3, but to different extents in each MR. This differential involvement of Gli3 explains the variation in phenotype among Gli3Xt-J/Xt-J MRs, and may help to understand the variation in numbers and positions of mammary glands among mammals. PMID:22046263

  6. IBM PC/IX operating system evaluation plan

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Granier, Martin; Hall, Philip P.; Triantafyllopoulos, Spiros

    1984-01-01

    An evaluation plan for the IBM PC/IX Operating System designed for IBM PC/XT computers is discussed. The evaluation plan covers the areas of performance measurement and evaluation, software facilities available, man-machine interface considerations, networking, and the suitability of PC/IX as a development environment within the University of Southwestern Louisiana NASA PC Research and Development project. In order to compare and evaluate the PC/IX system, comparisons with other available UNIX-based systems are also included.

  7. The Equilibrium and Pre-equilibrium Triton Emission Spectra of Some Target Nuclei for ( n, xt) Reactions up to 45 MeV Energy

    NASA Astrophysics Data System (ADS)

    Tel, E.; Kaplan, A.; Aydın, A.; Özkorucuklu, S.; Büyükuslu, H.; Yıldırım, G.

    2010-08-01

    Although there have been significant research and development studies on the inertial and magnetic fusion reactor technology, there is still a long way to go to penetrate commercial fusion reactors to the energy market. Tritium self-sufficiency must be maintained for a commercial power plant. For self-sustaining (D-T) fusion driver tritium breeding ratio should be greater than 1.05. So, working out the systematics of ( n,t) reaction cross sections and triton emission differential data are important for the given reaction taking place on various nuclei at different energies. In this study, ( n,xt) reactions for some target nuclei as 16O, 27Al, 59Co and 209Bi have been investigated up to 45 MeV incident neutron energy. In the calculations of the triton emission spectra, the pre-equilibrium and equilibrium effects have been used. The calculated results have been compared with the experimental data taken from the literature.

  8. Linear response to nonstationary random excitation.

    NASA Technical Reports Server (NTRS)

    Hasselman, T.

    1972-01-01

    Development of a method for computing the mean-square response of linear systems to nonstationary random excitation of the form given by y(t) = f(t) x(t), in which x(t) = a stationary process and f(t) is deterministic. The method is suitable for application to multidegree-of-freedom systems when the mean-square response at a point due to excitation applied at another point is desired. Both the stationary process, x(t), and the modulating function, f(t), may be arbitrary. The method utilizes a fundamental component of transient response dependent only on x(t) and the system, and independent of f(t) to synthesize the total response. The role played by this component is analogous to that played by the Green's function or impulse response function in the convolution integral.

  9. Dynamic Stability of Structures: Application to Frames, Cylindrical Shells and Other Systems.

    DTIC Science & Technology

    1982-02-01

    L0G XNX= XNXX 102. XNI:XNXX 102 GO TU 7-* 103 72 wRIkL(6,52)YFr4Xv XPKE.SONXvACCUR 104. XNXZXPRE. LOS XN11=XFRES 106 GO To 74. 107 73 WRITLC,5.3)Xt4X...YFviq~~ T19MAXvI,£LPRIN4TwwXNPvLP) 146 IF (iNxxF.xE.4)xPt~s=xWI IF (1NXXPX.tJE.4.) XNXX =XtAP 444 IDcz.T=IOT 147 IF (IsSF.tjE. )GO TO Z14 DC 213 :i1...T.IN& i-3T3(POT,PCrMq Sr TR TA qi~ IP Sv. ISA, XNXX 1263 C POT - F)TEN1TLAL EOi)RGY 1264. C STRY - U;JI TEND SHORTENIN.G FOR~ Yz0 * 1265 C STRA - .V-k-Gc

  10. Optimizing Blocking and Nonblocking Reduction Operations for Multicore Systems: Hierarchical Design and Implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorentla Venkata, Manjunath; Shamis, Pavel; Graham, Richard L

    2013-01-01

    Many scientific simulations, using the Message Passing Interface (MPI) programming model, are sensitive to the performance and scalability of reduction collective operations such as MPI Allreduce and MPI Reduce. These operations are the most widely used abstractions to perform mathematical operations over all processes that are part of the simulation. In this work, we propose a hierarchical design to implement the reduction operations on multicore systems. This design aims to improve the efficiency of reductions by 1) tailoring the algorithms and customizing the implementations for various communication mechanisms in the system 2) providing the ability to configure the depth ofmore » hierarchy to match the system architecture, and 3) providing the ability to independently progress each of this hierarchy. Using this design, we implement MPI Allreduce and MPI Reduce operations (and its nonblocking variants MPI Iallreduce and MPI Ireduce) for all message sizes, and evaluate on multiple architectures including InfiniBand and Cray XT5. We leverage and enhance our existing infrastructure, Cheetah, which is a framework for implementing hierarchical collective operations to implement these reductions. The experimental results show that the Cheetah reduction operations outperform the production-grade MPI implementations such as Open MPI default, Cray MPI, and MVAPICH2, demonstrating its efficiency, flexibility and portability. On Infini- Band systems, with a microbenchmark, a 512-process Cheetah nonblocking Allreduce and Reduce achieves a speedup of 23x and 10x, respectively, compared to the default Open MPI reductions. The blocking variants of the reduction operations also show similar performance benefits. A 512-process nonblocking Cheetah Allreduce achieves a speedup of 3x, compared to the default MVAPICH2 Allreduce implementation. On a Cray XT5 system, a 6144-process Cheetah Allreduce outperforms the Cray MPI by 145%. The evaluation with an application kernel

  11. System and method for constructing filters for detecting signals whose frequency content varies with time

    DOEpatents

    Qian, Shie; Dunham, Mark E.

    1996-01-01

    A system and method for constructing a bank of filters which detect the presence of signals whose frequency content varies with time. The present invention includes a novel system and method for developing one or more time templates designed to match the received signals of interest and the bank of matched filters use the one or more time templates to detect the received signals. Each matched filter compares the received signal x(t) with a respective, unique time template that has been designed to approximate a form of the signals of interest. The robust time domain template is assumed to be of the order of w(t)=A(t)cos{2.pi..phi.(t)} and the present invention uses the trajectory of a joint time-frequency representation of x(t) as an approximation of the instantaneous frequency function {.phi.'(t). First, numerous data samples of the received signal x(t) are collected. A joint time frequency representation is then applied to represent the signal, preferably using the time frequency distribution series (also known as the Gabor spectrogram). The joint time-frequency transformation represents the analyzed signal energy at time t and frequency .function., P(t,f), which is a three-dimensional plot of time vs. frequency vs. signal energy. Then P(t,f) is reduced to a multivalued function f(t), a two dimensional plot of time vs. frequency, using a thresholding process. Curve fitting steps are then performed on the time/frequency plot, preferably using Levenberg-Marquardt curve fitting techniques, to derive a general instantaneous frequency function .phi.'(t) which best fits the multivalued function f(t), a trajectory of the joint time-frequency domain representation of x(t). Integrating .phi.'(t) along t yields .phi.(t), which is then inserted into the form of the time template equation. A suitable amplitude A(t) is also preferably determined. Once the time template has been determined, one or more filters are developed which each use a version or form of the time template.

  12. Evaluation of a new nano-filled restorative material for bonding orthodontic brackets.

    PubMed

    Bishara, Samir E; Ajlouni, Raed; Soliman, Manal M; Oonsombat, Charuphan; Laffoon, John F; Warren, John

    2007-01-01

    To compare the shear bond strength of a nano-hybrid restorative material, Grandio (Voco, Cuxhaven, Germany), to that of a traditional adhesive material (Transbond XT; 3M Unitek, Monrovia, CA, USA) when bonding orthodontic brackets. Forty teeth were randomly divided into 2 groups: 20 teeth were bonded with the Transbond adhesive system and the other 20 teeth with the Grandio restorative system, following manufacturer's instructions. Student t test was used to compare the shear bond strength of the 2 systems. Significance was predetermined at P 5 .05. The t test comparisons (t = 0.55) of the shear bond strength between the 2 adhesives indicated the absence of a significant (P = .585) difference. The mean shear bond strength for Grandio was 4.1 +/- 2.6 MPa and that for Transbond XT was 4.6 +/- 3.2 MPa. During debonding, 3 of 20 brackets (15%) bonded with Grandio failed without registering any force on the Zwick recording. None of the brackets bonded with Transbond XT had a similar failure mode. The newly introduced nano-filled composite materials can potentially be used to bond orthodontic brackets to teeth if its consistency can be more flowable to readily adhere to the bracket base.

  13. Sedative and analgesic effects of intravenous xylazine and tramadol on horses

    PubMed Central

    Seo, Jong-pil; Son, Won-gyun; Gang, Sujin

    2011-01-01

    This study was performed to evaluate the sedative and analgesic effects of xylazine (X) and tramadol (T) intravenously (IV) administered to horses. Six thoroughbred saddle horses each received X (1.0 mg/kg), T (2.0 mg/kg), and a combination of XT (1.0 and 2.0 mg/kg, respectively) IV. Heart rate (HR), respiratory rate (RR), rectal temperature (RT), indirect arterial pressure (IAP), capillary refill time (CRT), sedation, and analgesia (using electrical stimulation and pinprick) were measured before and after drug administration. HR and RR significantly decreased from basal values with X and XT treatments, and significantly increased with T treatment (p < 0.05). RT and IAP also significantly increased with T treatment (p < 0.05). CRT did not change significantly with any treatments. The onset of sedation and analgesia were approximately 5 min after both X and XT treatments; however, the XT combination produced a longer duration of sedation and analgesia than X alone. Two horses in the XT treatment group displayed excited transient behavior within 5 min of drug administration. The results suggest that the XT combination is useful for sedation and analgesia in horses. However, careful monitoring for excited behavior shortly after administration is recommended. PMID:21897102

  14. Spectral assessment of new ASTER SWIR surface reflectance data products for spectroscopic mapping of rocks and minerals

    USGS Publications Warehouse

    Mars, J.C.; Rowan, L.C.

    2010-01-01

    ASTER reflectance spectra from Cuprite, Nevada, and Mountain Pass, California, were compared to spectra of field samples and to ASTER-resampled AVIRIS reflectance data to determine spectral accuracy and spectroscopic mapping potential of two new ASTER SWIR reflectance datasets: RefL1b and AST_07XT. RefL1b is a new reflectance dataset produced for this study using ASTER Level 1B data, crosstalk correction, radiance correction factors, and concurrently acquired level 2 MODIS water vapor data. The AST_07XT data product, available from EDC and ERSDAC, incorporates crosstalk correction and non-concurrently acquired MODIS water vapor data for atmospheric correction. Spectral accuracy was determined using difference values which were compiled from ASTER band 5/6 and 9/8 ratios of AST_07XT or RefL1b data subtracted from similar ratios calculated for field sample and AVIRIS reflectance data. In addition, Spectral Analyst, a statistical program that utilizes a Spectral Feature Fitting algorithm, was used to quantitatively assess spectral accuracy of AST_07XT and RefL1b data.Spectral Analyst matched more minerals correctly and had higher scores for the RefL1b data than for AST_07XT data. The radiance correction factors used in the RefL1b data corrected a low band 5 reflectance anomaly observed in the AST_07XT and AST_07 data but also produced anomalously high band 5 reflectance in RefL1b spectra with strong band 5 absorption for minerals, such as alunite. Thus, the band 5 anomaly seen in the RefL1b data cannot be corrected using additional gain adjustments. In addition, the use of concurrent MODIS water vapor data in the atmospheric correction of the RefL1b data produced datasets that had lower band 9 reflectance anomalies than the AST_07XT data. Although assessment of spectral data suggests that RefL1b data are more consistent and spectrally more correct than AST_07XT data, the Spectral Analyst results indicate that spectral discrimination between some minerals, such as

  15. Shear Bond Strength of Three Orthodontic Bonding Systems on Enamel and Restorative Materials.

    PubMed

    Hellak, Andreas; Ebeling, Jennifer; Schauseil, Michael; Stein, Steffen; Roggendorf, Matthias; Korbmacher-Steiner, Heike

    2016-01-01

    Objective. The aim of this in vitro study was to determine the shear bond strength (SBS) and adhesive remnant index (ARI) score of two self-etching no-mix adhesives (iBond ™ and Scotchbond ™ ) on different prosthetic surfaces and enamel, in comparison with the commonly used total etch system Transbond XT ™ . Materials and Methods . A total of 270 surfaces (1 enamel and 8 restorative surfaces, n = 30) were randomly divided into three adhesive groups. In group 1 (control) brackets were bonded with Transbond XT primer. In the experimental groups iBond adhesive (group 2) and Scotchbond Universal adhesive (group 3) were used. The SBS was measured using a Zwicki 1120 ™ testing machine. The ARI and SBS were compared statistically using the Kruskal-Wallis test ( P ≤ 0.05). Results . Significant differences in SBS and ARI were found between the control group and experimental groups. Conclusions . Transbond XT showed the highest SBS on human enamel. Scotchbond Universal on average provides the best bonding on all other types of surface (metal, composite, and porcelain), with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures on restorative materials in patients. If metal brackets have to be bonded to a metal surface, the use of a dual-curing resin is recommended.

  16. Neutron and X-ray Tomography (NeXT) system for simultaneous, dual modality tomography.

    PubMed

    LaManna, J M; Hussey, D S; Baltic, E; Jacobson, D L

    2017-11-01

    Dual mode tomography using neutrons and X-rays offers the potential of improved estimation of the composition of a sample from the complementary interaction of the two probes with the sample. We have developed a simultaneous neutron and 90 keV X-ray tomography system that is well suited to the study of porous media systems such as fuel cells, concrete, unconventional reservoir geologies, limestones, and other geological media. We present the characteristic performance of both the neutron and X-ray modalities. We illustrate the use of the simultaneous acquisition through improved phase identification in a concrete core.

  17. Neutron and X-ray Tomography (NeXT) system for simultaneous, dual modality tomography

    NASA Astrophysics Data System (ADS)

    LaManna, J. M.; Hussey, D. S.; Baltic, E.; Jacobson, D. L.

    2017-11-01

    Dual mode tomography using neutrons and X-rays offers the potential of improved estimation of the composition of a sample from the complementary interaction of the two probes with the sample. We have developed a simultaneous neutron and 90 keV X-ray tomography system that is well suited to the study of porous media systems such as fuel cells, concrete, unconventional reservoir geologies, limestones, and other geological media. We present the characteristic performance of both the neutron and X-ray modalities. We illustrate the use of the simultaneous acquisition through improved phase identification in a concrete core.

  18. Developmental validation of a Nextera XT mitogenome Illumina MiSeq sequencing method for high-quality samples.

    PubMed

    Peck, Michelle A; Sturk-Andreaggi, Kimberly; Thomas, Jacqueline T; Oliver, Robert S; Barritt-Ross, Suzanne; Marshall, Charla

    2018-05-01

    Generating mitochondrial genome (mitogenome) data from reference samples in a rapid and efficient manner is critical to harnessing the greater power of discrimination of the entire mitochondrial DNA (mtDNA) marker. The method of long-range target enrichment, Nextera XT library preparation, and Illumina sequencing on the MiSeq is a well-established technique for generating mitogenome data from high-quality samples. To this end, a validation was conducted for this mitogenome method processing up to 24 samples simultaneously along with analysis in the CLC Genomics Workbench and utilizing the AQME (AFDIL-QIAGEN mtDNA Expert) tool to generate forensic profiles. This validation followed the Federal Bureau of Investigation's Quality Assurance Standards (QAS) for forensic DNA testing laboratories and the Scientific Working Group on DNA Analysis Methods (SWGDAM) validation guidelines. The evaluation of control DNA, non-probative samples, blank controls, mixtures, and nonhuman samples demonstrated the validity of this method. Specifically, the sensitivity was established at ≥25 pg of nuclear DNA input for accurate mitogenome profile generation. Unreproducible low-level variants were observed in samples with low amplicon yields. Further, variant quality was shown to be a useful metric for identifying sequencing error and crosstalk. Success of this method was demonstrated with a variety of reference sample substrates and extract types. These studies further demonstrate the advantages of using NGS techniques by highlighting the quantitative nature of heteroplasmy detection. The results presented herein from more than 175 samples processed in ten sequencing runs, show this mitogenome sequencing method and analysis strategy to be valid for the generation of reference data. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Deciding alternative left turn signal phases using expert systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, E.C.P.

    1988-01-01

    The Texas Transportation Institute (TTI) conducted a study to investigate the feasibility of applying artificial intelligence (AI) technology and expert systems (ES) design concepts to a traffic engineering problem. Prototype systems were developed to analyze user input, evaluate various reasoning, and suggest suitable left turn phase treatment. These systems were developed using AI programming tools on IBM PC/XT/AT-compatible microcomputers. Two slightly different systems were designed using AI languages; another was built with a knowledge engineering tool. These systems include the PD PROLOG and TURBO PROLOG AI programs, as well as the INSIGHT Production Rule Language.

  20. Expert systems identify fossils and manage large paleontological databases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beightol, D.S.; Conrad, M.A.

    EXPAL is a computer program permitting creation and maintenance of comprehensive databases in marine paleontology. It is designed to assist specialists and non-specialists. EXPAL includes a powerful expert system based on the morphological descriptors specific to a given group of fossils. The expert system may be used, for example, to describe and automatically identify an unknown specimen. EXPAL was first applied to Dasycladales (Calcareous green algae). Projects are under way for corresponding expert systems and databases on planktonic foraminifers and calpionellids. EXPAL runs on an IBM XT or compatible microcomputer.

  1. Personal Computer System for Automatic Coronary Venous Flow Measurement

    PubMed Central

    Dew, Robert B.

    1985-01-01

    We developed an automated system based on an IBM PC/XT Personal computer to measure coronary venous blood flow during cardiac catheterization. Flow is determined by a thermodilution technique in which a cold saline solution is infused through a catheter into the coronary venous system. Regional temperature fluctuations sensed by the catheter are used to determine great cardiac vein and coronary sinus blood flow. The computer system replaces manual methods of acquiring and analyzing temperature data related to flow measurement, thereby increasing the speed and accuracy with which repetitive flow determinations can be made.

  2. Rating scale measures are associated with Noldus EthoVision-XT video tracking of behaviors of children on the autism spectrum

    PubMed Central

    2014-01-01

    Background Children with Autism Spectrum Disorder (ASD) show unusual social behaviors and repetitive behaviors. Some of these behaviors, e.g., time spent in an area or turning rate/direction, can be automatically tracked. Automated tracking has several advantages over subjective ratings including reliability, amount of information provided, and consistency across laboratories, and is potentially of importance for diagnosis, animal models and objective assessment of treatment efficacy. However, its validity for ASD has not been examined. In this exploratory study, we examined associations between rating scale data with automated tracking of children’s movements using the Noldus EthoVision XT system; i.e., tracking not involving a human observer. Based on our observations and previous research, we predicted that time spent in the periphery of the room would be associated with autism severity and that rate and direction of turning would be associated with stereotypies. Methods Children with and without ASD were observed in a free-play situation for 3 min before and 3 min after Autism Diagnostic Observation Scale – Generic (ADOS-G) testing. The Noldus system provided measures of the rate and direction of turning, latency to approach and time spend near the periphery or the parent. Results Ratings of the severity of maladaptive social behaviors, stereotypies, autism severity, and arousal problems were positively correlated with increases in percent time spent in the periphery in the total sample and in the ASD subset. Adaptive social communication skills decreased with increases in the percentage of time spent in the periphery and increases in the latency to approach the parent in the ASD group. The rate and direction of turning was linked with stereotypies only in the group without ASD (the faster the rate of a turn to the left, the worse the rating). In the ASD group, there was a shift from a neutral turning bias prior to the ADOS assessment to a strong left

  3. Abnormal Positioning of Diencephalic Cell Types in Neocortical Tissue in the Dorsal Telencephalon of Mice Lacking Functional Gli3

    PubMed Central

    Fotaki, Vassiliki; Yu, Tian; Zaki, Paulette A.; Mason, John O.; Price, David J.

    2008-01-01

    The transcription factor Gli3 (glioma-associated oncogene homolog) is essential for normal development of the mammalian forebrain. One extreme requirement for Gli3 is at the dorsomedial telencephalon, which does not form in Gli3Xt/Xt mutant mice lacking functional Gli3. In this study, we analyzed expression of Gli3 in the wild-type telencephalon and observed a highdorsal-to-lowventral gradient of Gli3 expression and predominance of the cleaved form of the Gli3 protein dorsally. This graded expression correlates with the severedorsal-to-mildventral telencephalic phenotype observed in Gli3Xt/Xt mice. We characterized the abnormal joining of the telencephalon to the diencephalon and defined the medial limit of the dorsal telencephalon in Gli3Xt/Xt mice early in corticogenesis. Based on this analysis, we concluded that some of the abnormal expression of ventral telencephalic markers previously described as being in the dorsal telencephalon is, in fact, expression in adjacent diencephalic tissue, which expresses many of the same genes that mark the ventral telencephalon. We observed occasional cells with diencephalic character in the Foxg1 (forkhead box)-expressing Gli3Xt/Xt telencephalon at embryonic day 10.5, a day after the anatomical subdivision of the forebrain vesicle. Large clusters of such cells appear in the Gli3Xt/Xt neocortical region at later ages, when the neocortex becomes highly disorganized, forming rosettes comprising mainly neural progenitors. We propose that Gli3 is indispensable for formation of an intact telencephalic-diencephalic boundary and for preventing the abnormal positioning of diencephalic cells in the dorsal telencephalon. PMID:16957084

  4. The effect of X-ray beam distortion on the Edwards Sapien XT(™) trans-catheter aortic valve replacement prosthesis.

    PubMed

    Crowhurst, James A; Poon, Karl K; Murdoch, Dale; Incani, Alexander; Raffel, Owen C; Liddicoat, Annelise; Walters, Darren

    2015-12-01

    Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans-catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X-ray beam from the C-arm altered the appearance of the TAVR device. Under bench-top testing, a 23, 26 and 29 mm Edwards Sapien XT valve was positioned coaxially at the bottom of a fluoroscopic image utilising 22 and 32 cm fields of view (FOV). The table was then moved so that the valve was positioned at the top of the image. The valve's appearance was scored using a previously published three tier classification tool (excellent, satisfactory and poor) and quantified with measurements. The number of degrees of C-arm rotation that were required to bring the valve back to a coaxial appearance was recorded. When using the 32 cm FOV, the valve's appearance changes from excellent to satisfactory. When a 22 cm FOV was used, the change is less marked. More C-arm rotation is required to bring the appearance back to coaxial with the 32 cm FOV. Not maintaining the valve in the centre of the image can distort the valves appearance. This has the potential to affect the final implantation depth.

  5. The Netherlands XTC Toxicity (NeXT) study: objectives and methods of a study investigating causality, course, and clinical relevance.

    PubMed

    De Win, Maartje M L; Jager, Gerry; Vervaeke, Hylke K E; Schilt, Thelma; Reneman, Liesbeth; Booij, Jan; Verhulst, Frank C; Den Heeten, Gerard J; Ramsey, Nick F; Korf, Dirk J; Van den Brink, Wim

    2005-01-01

    This paper describes the objectives and methods of The Netherlands XTC Toxicity (NeXT) study focussing on the causality, course, and clinical relevance of ecstasy neurotoxicity. Previous studies suggest that ecstasy (3,4 methylene-dioxymethamphetamine, MDMA, XTC) is toxic toward brain serotonin axons, but most of these studies have serious methodological limitations. The current study is a combination of different approaches with three substudies: (1) a crosssectional substudy among heavy ecstasy users and controls with variation in drug use, which will provide information about potential neurotoxic consequences of ecstasy in relation to other drugs; (2) a prospective cohort substudy in ecstasy-naive subjects with high risk for future ecstasy use, which will provide information on the causality and short-term course of ecstasy use and potential neurotoxicity, and (3) a retrospective cohort substudy in lifetime ecstasy users and matched controls of an existing epidemiological sample that will provide information on long-term course and outcome of ecstasy use in the general population. Neurotoxicity is studied using (a) different imaging techniques (beta-CIT SPECT, 1H-MR spectroscopy, diffusion tensor imaging, perfusion weighted imaging and functional magnetic resonance imaging), and (b) neuropsychological and psychiatric assessments of memory, depression, and personality. The combined results will lead to conclusions that can be used in prevention messages, clinical decision making, and the development of an (inter)national ecstasy policy.

  6. Bonding brackets on white spot lesions pretreated by means of two methods.

    PubMed

    Vianna, Julia Sotero; Marquezan, Mariana; Lau, Thiago Chon Leon; Sant'Anna, Eduardo Franzotti

    2016-01-01

    The aim of this study was to evaluate the shear bond strength (SBS) of brackets bonded to demineralized enamel pretreated with low viscosity Icon Infiltrant resin (DMG) and glass ionomer cement (Clinpro XT Varnish, 3M Unitek) with and without aging. A total of 75 bovine enamel specimens were allocated into five groups (n = 15). Group 1 was the control group in which the enamel surface was not demineralized. In the other four groups, the surfaces were submitted to cariogenic challenge and white spot lesions were treated. Groups 2 and 3 were treated with Icon Infiltrant resin; Groups 4 and 5, with Clinpro XT Varnish. After treatment, Groups 3 and 5 were artificially aged. Brackets were bonded with Transbond XT adhesive system and SBS was evaluated by means of a universal testing machine. Statistical analysis was performed by one-way analysis of variance followed by Tukey post-hoc test. All groups tested presented shear bond strengths similar to or higher than the control group. Specimens of Group 4 had significantly higher shear bond strength values (p < 0.05) than the others. Pretreatment of white spot lesions, with or without aging, did not decrease the SBS of brackets.

  7. Effect of blood and saliva contamination on bond strength of brackets bonded with a protective liquid polish and a light-cured adhesive.

    PubMed

    Sayinsu, Korkmaz; Isik, Fulya; Sezen, Serdar; Aydemir, Bulent

    2007-03-01

    The application of a polymer coating to the labial enamel tooth surface before bonding can help keep white spot lesions from forming. Previous studies evaluating the effects of blood and saliva contamination on the bond strengths of light-cured composites showed significant reductions in bond strength values. The purpose of this study was to investigate whether the bond strength of a light-cured system (Transbond XT, 3M Unitek, Puchheim, Germany) used with a liquid polish (BisCover, Bisco, Schaumburg, Ill) is affected by contamination with blood or saliva. One hundred twenty permanent human premolars were randomly divided into 6 groups of 20. Various enamel surface conditions were studied: dry, blood contaminated, and saliva contaminated. A light-cured bonding system (Transbond XT) was used in all groups. The teeth in group 1 were bonded with Transbond XT. In the second group, BisCover polymeric resin polish was applied on the etched tooth surfaces before the brackets were bonded with Transbond XT resin. Comparison of the first and second groups showed no statistically significant difference. Groups 3 through 6 were bonded without Transbond XT. For groups 3 and 5, a layer of blood or saliva, respectively, was applied to the etched enamel followed by BisCover. In groups 4 and 6, blood or saliva, respectively, was applied on the light-cured BisCover. Shear forces were applied to the samples with a universal testing machine, and bond strengths were measured in megapascals. The protective liquid polish (BisCover) layer did not affect bond strength. Blood contamination on acid-etched surfaces affects bond strength more than saliva contamination. When a protective liquid polish (BisCover) is applied to the tooth surface, the effect of contamination by blood or saliva is prevented.

  8. System and method for detection of dispersed broadband signals

    DOEpatents

    Qian, Shie; Dunham, Mark E.

    1999-06-08

    A system and method for detecting the presence of dispersed broadband signals in real time. The present invention utilizes a bank of matched filters for detecting the received dispersed broadband signals. Each matched filter uses a respective robust time template that has been designed to approximate the dispersed broadband signals of interest, and each time template varies across a spectrum of possible dispersed broadband signal time templates. The received dispersed broadband signal x(t) is received by each of the matched filters, and if one or more matches occurs, then the received data is determined to have signal data of interest. This signal data can then be analyzed and/or transmitted to Earth for analysis, as desired. The system and method of the present invention will prove extremely useful in many fields, including satellite communications, plasma physics, and interstellar research. The varying time templates used in the bank of matched filters are determined as follows. The robust time domain template is assumed to take the form w(t)=A(t)cos{2.phi.(t)}. Since the instantaneous frequency f(t) is known to be equal to the derivative of the phase .phi.(t), the trajectory of a joint time-frequency representation of x(t) is used as an approximation of .phi.'(t).

  9. General specifications for the development of a PC-based simulator of the NASA RECON system

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Triantafyllopoulos, Spiros

    1984-01-01

    The general specifications for the design and implementation of an IBM PC/XT-based simulator of the NASA RECON system, including record designs, file structure designs, command language analysis, program design issues, error recovery considerations, and usage monitoring facilities are discussed. Once implemented, such a simulator will be utilized to evaluate the effectiveness of simulated information system access in addition to actual system usage as part of the total educational programs being developed within the NASA contract.

  10. Dietary supplementation of young broiler chickens with Capsicum and turmeric oleoresins increases resistance to necrotic enteritis.

    PubMed

    Lee, Sung Hyen; Lillehoj, Hyun S; Jang, Seung I; Lillehoj, Erik P; Min, Wongi; Bravo, David M

    2013-09-14

    The Clostridium-related poultry disease, necrotic enteritis (NE), causes substantial economic losses on a global scale. In the present study, a mixture of two plant-derived phytonutrients, Capsicum oleoresin and turmeric oleoresin (XT), was evaluated for its effects on local and systemic immune responses using a co-infection model of experimental NE in commercial broilers. Chickens were fed from hatch with a diet supplemented with XT, or with a non-supplemented control diet, and either uninfected or orally challenged with virulent Eimeria maxima oocysts at 14 d and Clostridium perfringens at 18 d of age. Parameters of protective immunity were as follows: (1) body weight; (2) gut lesions; (3) serum levels of C. perfringens α-toxin and NE B-like (NetB) toxin; (4) serum levels of antibodies to α-toxin and NetB toxin; (5) levels of gene transcripts encoding pro-inflammatory cytokines and chemokines in the intestine and spleen. Infected chickens fed the XT-supplemented diet had increased body weight and reduced gut lesion scores compared with infected birds given the non-supplemented diet. The XT-fed group also displayed decreased serum α-toxin levels and reduced intestinal IL-8, lipopolysaccharide-induced TNF-α factor (LITAF), IL-17A and IL-17F mRNA levels, while cytokine/chemokine levels in splenocytes increased in the XT-fed group, compared with the animals fed the control diet. In conclusion, the present study documents the molecular and cellular immune changes following dietary supplementation with extracts of Capsicum and turmeric that may be relevant to protective immunity against avian NE.

  11. Structure determination of the extracellular xylanase from Geobacillus stearothermophilus by selenomethionyl MAD phasing.

    PubMed

    Teplitsky, A; Mechaly, A; Stojanoff, V; Sainz, G; Golan, G; Feinberg, H; Gilboa, R; Reiland, V; Zolotnitsky, G; Shallom, D; Thompson, A; Shoham, Y; Shoham, G

    2004-05-01

    Xylanases are hemicellulases that hydrolyze the internal beta-1,4-glycoside bonds of xylan. The extracellular thermostable endo-1,4-beta-xylanase (EC 3.2.1.8; XT6) produced by the thermophilic bacterium Geobacillus stearothermophilus T-6 was shown to bleach pulp optimally at pH 9 and 338 K and was successfully used in a large-scale biobleaching mill trial. The xylanase gene was cloned and sequenced. The mature enzyme consists of 379 amino acids, with a calculated molecular weight of 43 808 Da and a pI of 9.0. Crystallographic studies of XT6 were performed in order to study the mechanism of catalysis and to provide a structural basis for the rational introduction of enhanced thermostability by site-specific mutagenesis. XT6 was crystallized in the primitive trigonal space group P3(2)21, with unit-cell parameters a = b = 112.9, c = 122.7 A. A full diffraction data set for wild-type XT6 has been measured to 2.4 A resolution on flash-frozen crystals using synchrotron radiation. A fully exchanged selenomethionyl XT6 derivative (containing eight Se atoms per XT6 molecule) was also prepared and crystallized in an isomorphous crystal form, providing full selenium MAD data at three wavelengths and enabling phase solution and structure determination. The structure of wild-type XT6 was refined at 2.4 A resolution to a final R factor of 15.6% and an R(free) of 18.6%. The structure demonstrates that XT6 is made up of an eightfold TIM-barrel containing a deep active-site groove, consistent with its 'endo' mode of action. The two essential catalytic carboxylic residues (Glu159 and Glu265) are located at the active site within 5.5 A of each other, as expected for 'retaining' glycoside hydrolases. A unique subdomain was identified in the carboxy-terminal part of the enzyme and was suggested to have a role in xylan binding. The three-dimensional structure of XT6 is of great interest since it provides a favourable starting point for the rational improvement of its already high

  12. Deploying Server-side File System Monitoring at NERSC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uselton, Andrew

    2009-05-01

    The Franklin Cray XT4 at the NERSC center was equipped with the server-side I/O monitoring infrastructure Cerebro/LMT, which is described here in detail. Insights gained from the data produced include a better understanding of instantaneous data rates during file system testing, file system behavior during regular production time, and long-term average behaviors. Information and insights gleaned from this monitoring support efforts to proactively manage the I/O infrastructure on Franklin. A simple model for I/O transactions is introduced and compared with the 250 million observations sent to the LMT database from August 2008 to February 2009.

  13. Fast Numerical Methods for Stochastic Partial Differential Equations

    DTIC Science & Technology

    2016-04-15

    analysis we first derived a system of forward and backward SDEs (BSDEs) for (Xt, Qt, Zt){ dXs = b( Xs )dt+ σsdWs, Xt = x, t < s < T, (SDE) dQs = ZsdWs...g( Xs )QsdVs, QT = Φ(XT ). (BSDE) (6) Here Wt and Vt are two independent Brownian motions. The first equation in (6) is a forward SDE while the second...first order scheme for a general coupled system of forward-backward SDEs [1]: dXs = b( Xs )ds+ σ( Xs )dWs, t ≤ s ≤ T, dYs = +f(s, Xs , Ys)ds +g(s

  14. Optimal Control of a Brownian Storage System

    DTIC Science & Technology

    1976-09-01

    subject to the constraint that W(t) = X(t) + Y(t) - Z(t) > 0 for all t > 0 (almost surely). It is the hypothesized structure of costs and rewards that...or a bank account ) whose content evolves as the Brownian Motion X in the absence of any control In particular, X(O.) represents the initial content...however then the controller is obliged to inject material into the system so as to keep the net content positive, and he incurs a cost of k > I

  15. System and method for detection of dispersed broadband signals

    DOEpatents

    Qian, S.; Dunham, M.E.

    1999-06-08

    A system and method for detecting the presence of dispersed broadband signals in real time are disclosed. The present invention utilizes a bank of matched filters for detecting the received dispersed broadband signals. Each matched filter uses a respective robust time template that has been designed to approximate the dispersed broadband signals of interest, and each time template varies across a spectrum of possible dispersed broadband signal time templates. The received dispersed broadband signal x(t) is received by each of the matched filters, and if one or more matches occurs, then the received data is determined to have signal data of interest. This signal data can then be analyzed and/or transmitted to Earth for analysis, as desired. The system and method of the present invention will prove extremely useful in many fields, including satellite communications, plasma physics, and interstellar research. The varying time templates used in the bank of matched filters are determined as follows. The robust time domain template is assumed to take the form w(t)=A(t)cos[l brace]2[phi](t)[r brace]. Since the instantaneous frequency f(t) is known to be equal to the derivative of the phase [phi](t), the trajectory of a joint time-frequency representation of x(t) is used as an approximation of [phi][prime](t). 10 figs.

  16. Effect of Accelerated Artificial Aging on Translucency of Methacrylate and Silorane-Based Composite Resins.

    PubMed

    Shirinzad, Mehdi; Rezaei-Soufi, Loghman; Mirtorabi, Maryam Sadat; Vahdatinia, Farshid

    2016-03-01

    Composite restorations must have tooth-like optical properties namely color and translucency and maintain them for a long time. This study aimed to compare the effect of accelerated artificial aging (AAA) on the translucency of three methacrylate-based composites (Filtek Z250, Filtek Z250XT and Filtek Z350XT) and one silorane-based composite resin (Filtek P90). For this in vitro study, 56 composite discs were fabricated (n=14 for each group). Using scanning spectrophotometer, CIE L*a*b* parameters and translucency of each specimen were measured at 24 hours and after AAA for 384 hours. Data were analyzed using one-way ANOVA, Tukey's test and paired t-test at P=0.05 level of significance. The mean (±standard deviation) translucency parameter for Filtek Z250, Filtek Z250XT, Filtek Z350XT and Filtek P90 was 5.67±0.64, 4.59±0.77, 7.87±0.82 and 4.21±0.71 before AAA and 4.25±0.615, 3.53±0.73, 5.94±0.57 and 4.12±0.54 after AAA, respectively. After aging, the translucency of methacrylate-based composites decreased significantly (P<0.05). However, the translucency of Filtek P90 did not change significantly (P>0.05). The AAA significantly decreased the translucency of methacrylate-based composites (Filtek Z250, Filtek Z250XT and Filtek Z350XT) but no change occurred in the translucency of Filtek P90 silorane-based composite.

  17. Effect of Accelerated Artificial Aging on Translucency of Methacrylate and Silorane-Based Composite Resins

    PubMed Central

    Shirinzad, Mehdi; Rezaei-Soufi, Loghman; Mirtorabi, Maryam Sadat; Vahdatinia, Farshid

    2016-01-01

    Objectives: Composite restorations must have tooth-like optical properties namely color and translucency and maintain them for a long time. This study aimed to compare the effect of accelerated artificial aging (AAA) on the translucency of three methacrylate-based composites (Filtek Z250, Filtek Z250XT and Filtek Z350XT) and one silorane-based composite resin (Filtek P90). Materials and Methods: For this in vitro study, 56 composite discs were fabricated (n=14 for each group). Using scanning spectrophotometer, CIE L*a*b* parameters and translucency of each specimen were measured at 24 hours and after AAA for 384 hours. Data were analyzed using one-way ANOVA, Tukey's test and paired t-test at P=0.05 level of significance. Results: The mean (±standard deviation) translucency parameter for Filtek Z250, Filtek Z250XT, Filtek Z350XT and Filtek P90 was 5.67±0.64, 4.59±0.77, 7.87±0.82 and 4.21±0.71 before AAA and 4.25±0.615, 3.53±0.73, 5.94±0.57 and 4.12±0.54 after AAA, respectively. After aging, the translucency of methacrylate-based composites decreased significantly (P<0.05). However, the translucency of Filtek P90 did not change significantly (P>0.05). Conclusions: The AAA significantly decreased the translucency of methacrylate-based composites (Filtek Z250, Filtek Z250XT and Filtek Z350XT) but no change occurred in the translucency of Filtek P90 silorane-based composite. PMID:27928237

  18. Performance Assessment of the Spare Parts for the Activation of Relocated Systems (SPARES) Forecasting Model

    DTIC Science & Technology

    1991-09-01

    constant data into the gaining base’s computer records. Among the data elements to be loaded, the 1XT434 image contains the level detail effective date...the mission support effective date, and the PBR override (19:19-203). In conjunction with the 1XT434, the Mission Change Parameter Image (Constant...the gaining base (19:19-208). The level detail effective date establishes the date the MCDDFR and MCDDR "are considered by the requirements computation

  19. Kinetics and mechanism for platination of thione-containing nucleotides and oligonucleotides: evaluation of the salt dependence.

    PubMed

    Kjellström, Johan; Elmroth, Sofi K C

    2003-01-01

    Reactions of cis-[PtCl(NH(3))(CyNH(2))(OH(2))](+) (Cy=cyclohexyl) with thione-containing single-stranded oligonucleotides d(T(8)XT(8)) and d(XT(16)) (X=(s6)I or (s4)U) and the mononucleotides 4-thiouridine ((s4)UMP) and 6-mercaptoinosine ((s6)IMP) have been studied in aqueous solution at pH 4.1. The reaction kinetics was followed using HPLC methodology as a function of ionic strength in the interval 5.0 mMsystems. The rate for adduct formation with the oligonucleotides d(T(8)XT(8)) and d(XT(16)) decreases with increasing ionic strength of the medium. The effect is most pronounced for adduct formation with the middle positions, e.g. for d(T(8)(s6)IT(8)): k(2,app)=370 M(-1 )s(-1) and 13 M(-1 )s(-1) at I=5.0 and 300 mM, respectively, and slightly less pronounced for adduct formation at the end positions, e.g. for d((s6)IT(16)): k(2,app)=130 M(-1 )s(-1) and 11 M(-1 )s(-1) at I=5.0 and 300 mM, respectively. Analysis of the salt dependence using the Brønsted-Debye-Hückel relationship shows that the reactions with the monomers are well described as an interaction between a monovalent cation and a monovalent anion. In contrast, a similar analysis of the oligonucleotide reactions indicates influence from polyelectrolyte effects. The results support a mechanism in which pre-association on the DNA surface precedes adduct formation, regardless of the exact location of the final binding site.

  20. Anxa4 Genes are Expressed in Distinct Organ Systems in Xenopus laevis and tropicalis But are Functionally Conserved

    PubMed Central

    Massé, Karine L; Collins, Robert J; Bhamra, Surinder; Seville, Rachel A

    2007-01-01

    Anxa4 belongs to the multigenic annexin family of proteins which are characterized by their ability to interact with membranes in a calcium-dependent manner. Defined as a marker for polarized epithelial cells, Anxa4 is believed to be involved in many cellular processes but its functions in vivo are still poorly understood. Previously, we cloned Xanx4 in Xenopus laevis (now referred to as anxa4a) and demonstrated its role during organogenesis of the pronephros, providing the first evidence of a specific function for this protein during the development of a vertebrate. Here, we describe the strict conservation of protein sequence and functional domains of anxa4 during vertebrate evolution. We also identify the paralog of anxa4a, anxa4b and show its specific temporal and spatial expression pattern is different from anxa4a. We show that anxa4 orthologs in X. laevis and tropicalis display expression domains in different organ systems. Whilst the anxa4a gene is mainly expressed in the kidney, Xt anxa4 is expressed in the liver. Finally, we demonstrate Xt anxa4 and anxa4a can display conserved function during kidney organogenesis, despite the fact that Xt anxa4 transcripts are not expressed in this domain. This study highlights the divergence of expression of homologous genes during Xenopus evolution and raises the potential problems of using X. tropicalis promoters in X. laevis. PMID:19279706

  1. Advanced and flexible multi-carrier receiver architecture for high-count multi-core fiber based space division multiplexed applications

    PubMed Central

    Asif, Rameez

    2016-01-01

    Space division multiplexing (SDM), incorporating multi-core fibers (MCFs), has been demonstrated for effectively maximizing the data capacity in an impending capacity crunch. To achieve high spectral-density through multi-carrier encoding while simultaneously maintaining transmission reach, benefits from inter-core crosstalk (XT) and non-linear compensation must be utilized. In this report, we propose a proof-of-concept unified receiver architecture that jointly compensates optical Kerr effects, intra- and inter-core XT in MCFs. The architecture is analysed in multi-channel 512 Gbit/s dual-carrier DP-16QAM system over 800 km 19-core MCF to validate the digital compensation of inter-core XT. Through this architecture: (a) we efficiently compensates the inter-core XT improving Q-factor by 4.82 dB and (b) achieve a momentous gain in transmission reach, increasing the maximum achievable distance from 480 km to 1208 km, via analytical analysis. Simulation results confirm that inter-core XT distortions are more relentless for cores fabricated around the central axis of cladding. Predominantly, XT induced Q-penalty can be suppressed to be less than 1 dB up-to −11.56 dB of inter-core XT over 800 km MCF, offering flexibility to fabricate dense core structures with same cladding diameter. Moreover, this report outlines the relationship between core pitch and forward-error correction (FEC). PMID:27270381

  2. 21 CFR 820.5 - Quality system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Quality system. 820.5 Section 820.5 Food and Drugs... QUALITY SYSTEM REGULATION General Provisions § 820.5 Quality system. Each manufacturer shall establish and maintain a quality system that is appropriate for the specific medical device(s) designed or manufactured...

  3. 21 CFR 820.5 - Quality system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Quality system. 820.5 Section 820.5 Food and Drugs... QUALITY SYSTEM REGULATION General Provisions § 820.5 Quality system. Each manufacturer shall establish and maintain a quality system that is appropriate for the specific medical device(s) designed or manufactured...

  4. 21 CFR 820.5 - Quality system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality system. 820.5 Section 820.5 Food and Drugs... QUALITY SYSTEM REGULATION General Provisions § 820.5 Quality system. Each manufacturer shall establish and maintain a quality system that is appropriate for the specific medical device(s) designed or manufactured...

  5. 5 CFR 430.204 - Agency performance appraisal system(s).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Agency performance appraisal system(s... Other Employees § 430.204 Agency performance appraisal system(s). (a) Each agency as defined at section 4301(1) of title 5, United States Code, shall develop one or more performance appraisal systems for...

  6. Effect of thermal aging on the tensile bond strength at reduced areas of seven current adhesives.

    PubMed

    Baracco, Bruno; Fuentes, M Victoria; Garrido, Miguel A; González-López, Santiago; Ceballos, Laura

    2013-07-01

    The purpose of this study was to determine the micro-tensile bond strength (MTBS) to dentin of seven adhesive systems (total and self-etch adhesives) after 24 h and 5,000 thermocycles. Dentin surfaces of human third molars were exposed and bonded with two total-etch adhesives (Adper Scotchbond 1 XT and XP Bond), two two-step self-etch adhesives (Adper Scotchbond SE and Filtek Silorane Adhesive System) and three one-step self-etch adhesives (G-Bond, Xeno V and Bond Force). All adhesive systems were applied following manufacturers' instructions. Composite buildups were constructed and the bonded teeth were then stored in water (24 h, 37 °C) or thermocycled (5,000 cycles) before being sectioned and submitted to MTBS test. Two-way ANOVA and subsequent comparison tests were applied at α = 0.05. Characteristic de-bonded specimens were analyzed using scanning electron microscopy (SEM). After 24 h water storage, MTBS values were highest with XP Bond, Adper Scotchbond 1 XT, Filtek Silorane Adhesive System and Adper Scotchbond SE and lowest with the one-step self-etch adhesives Bond Force, Xeno V and G-Bond. After thermocycling, MTBS values were highest with XP Bond, followed by Filtek Silorane Adhesive System, Adper Scotchbond SE and Adper Scotchbond 1 XT and lowest with the one-step self-etch adhesives Bond Force, Xeno V and G-Bond. Thermal aging induced a significant decrease in MTBS values with all adhesives tested. The resistance of resin-dentin bonds to thermal-aging degradation was material dependent. One-step self-etch adhesives obtained the lowest MTBS results after both aging treatments, and their adhesive capacity was significantly reduced after thermocycling.

  7. Color stability of nanocomposites polished with one-step systems.

    PubMed

    Ergücü, Zeynep; Türkün, L Sebnem; Aladag, Akin

    2008-01-01

    This study compared the color changes of five novel resin composites polished with two one-step polishing systems when exposed to coffee solution. The resin composites tested were Filtek Supreme XT, Grandio, CeramX, Premise and Tetric EvoCeram. A total of 150 discs (30/resin composites, 10 x 2 mm) were fabricated. Ten specimens/resin composites cured under Mylar strips served as the control. The other samples were polished with PoGo and OptraPol discs for 30 seconds using a slow speed handpiece and immersed in coffee (Nescafé) for seven days. Color measurements were made with Vita Easyshade at baseline and after one and seven days. Repeated Measures ANOVA and Bonferroni tests were used for statistical analyses (p< or =0.05). The differences between the mean DeltaE* values for the resin composites polished with two different one-step systems were statistically significant (p<0.05). After one week, all materials exhibited significant color changes compared to baseline. All Mylar finished specimens showed the most intense staining (p<0.05). There were no significant differences between the OptraPol and PoGo polished groups. Mylar-finished specimens of CeramX, Tetric EvoCeram, Premise and Filtek Supreme XT presented the greatest staining (p<0.05). For Grandio, there were no significant differences between the Mylar and PoGo groups, while the most stain resistant surfaces were attained with OptraPol. Removing the outermost resin layer by polishing procedures is essential to achieving a stain resistant, more esthetically stable surface. One-step polishing systems can be used successfully for polishing nanocomposites.

  8. On Wave and Entropic Amplitudes in Maxwellian Materials.

    DTIC Science & Technology

    1982-09-01

    drawbacks. Finally, in the last of a major series of papers on the propagation and growth "" behavior of waves in materials with memory, Coleman, Greenberg ...equations to calculate xa T 1C. As in Coleman, Greenberg , and Gurtin [5], we may then replace [at a xT 1 by [ at T]. Now, at all points (X,t) (Y(t),t...behavior of the amplitude, a(t), is based on this fact and the continuity of I(t). Following Coleman, Greenberg , and Gurtin [5] we set (5.8) (t ) -1/I(t ) 0

  9. 48 CFR 215.407-5 - Estimating systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...

  10. 48 CFR 215.407-5 - Estimating systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...

  11. 48 CFR 215.407-5 - Estimating systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...

  12. 48 CFR 215.407-5 - Estimating systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...

  13. 48 CFR 215.407-5 - Estimating systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...

  14. CLIPSITS - CLIPS INTELLIGENT TUTORING SYSTEM

    NASA Technical Reports Server (NTRS)

    Riley, G.

    1994-01-01

    The CLIPS Intelligent Tutoring System (CLIPSITS) is designed to be used to learn CLIPS, the C-language Integrated Production System expert system shell developed by the Software Technology Branch at Johnson Space Center. The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. This version of CLIPSITS is compatible with the Version 4.2 and 4.3 CLIPS User's Guide. However, the program does not cover any new features of CLIPS v4.3 that were added since the release of v4.2. The chapter numbers in the CLIPS User's Guide correspond directly with the lesson numbers in CLIPSITS. Each lesson in the program contains anywhere from 1 to 10 problems. Most of these have multiple parts. The student is given a subset of these problems from each lesson to work. The actual number of problems presented depends on how well the student masters the previous problem(s). The progression through these lessons is maintained in a personalized file under the student's name. As with most computer languages, there is usually more than one way to solve a problem. CLIPSITS attempts to be as flexible as possible and to allow as many correct solutions as possible. CLIPSITS gives the student the option of setting his/her own colors for the screen interface and the option of redefining special keystroke combinations used within the program. CLIPSITS requires an IBM PC compatible with 640K RAM and optional 2 or 3 button mouse. A 286- or 386-based machine is preferable. Performance will be somewhat slower on an XT class machine. The program must be installed on a hard disk with 825 KB space available. The program was developed in 1989. The standard distribution media is three 5.25" IBM PC DOS format

  15. Global Precipitation Estimates from Cross-Track Passive Microwave Observations Using a Physically-Based Retrieval Scheme

    NASA Technical Reports Server (NTRS)

    Kidd, Chris; Matsui, Toshi; Chern, Jiundar; Mohr, Karen; Kummerow, Christian; Randel, Dave

    2015-01-01

    The estimation of precipitation across the globe from satellite sensors provides a key resource in the observation and understanding of our climate system. Estimates from all pertinent satellite observations are critical in providing the necessary temporal sampling. However, consistency in these estimates from instruments with different frequencies and resolutions is critical. This paper details the physically based retrieval scheme to estimate precipitation from cross-track (XT) passive microwave (PM) sensors on board the constellation satellites of the Global Precipitation Measurement (GPM) mission. Here the Goddard profiling algorithm (GPROF), a physically based Bayesian scheme developed for conically scanning (CS) sensors, is adapted for use with XT PM sensors. The present XT GPROF scheme utilizes a model-generated database to overcome issues encountered with an observational database as used by the CS scheme. The model database ensures greater consistency across meteorological regimes and surface types by providing a more comprehensive set of precipitation profiles. The database is corrected for bias against the CS database to ensure consistency in the final product. Statistical comparisons over western Europe and the United States show that the XT GPROF estimates are comparable with those from the CS scheme. Indeed, the XT estimates have higher correlations against surface radar data, while maintaining similar root-mean-square errors. Latitudinal profiles of precipitation show the XT estimates are generally comparable with the CS estimates, although in the southern midlatitudes the peak precipitation is shifted equatorward while over the Arctic large differences are seen between the XT and the CS retrievals.

  16. Performance analysis of newly developed point-of-care hemoglobinometer (TrueHb) against an automated hematology analyzer (Sysmex XT 1800i) in terms of precision in hemoglobin measurement.

    PubMed

    Srivastava, A; Koul, V; Dwivedi, S N; Upadhyaya, A D; Ahuja, A; Saxena, R

    2015-08-01

    The aim of this study was to evaluate the performance of the newly developed handheld hemoglobinmeter (TrueHb) by comparing its performance against and an automated five-part hematology analyzer, Sysmex counter XT 1800i (Sysmex). Two hundred venous blood samples were subjected through their total hemoglobin evaluation on each device three times. The average of the three readings on each device was considered as their respective device values, that is, TrueHb values and Sysmex values. The two set of values were comparatively analyzed. The repeatability of the performance of TrueHb was also evaluated against Sysmex values. The scatter plot of TrueHb values and Sysmex values showed linear distribution with positive correlations (r = 0.99). The intraclass correlation (ICC) values between the two set of values was found to be 0.995. Regression coefficients through origin, β, was found to be 0.995, with 95% confidence intervals (CI) ranging between 0.9900 and 1.0000. The mean difference in Bland-Altman plots of TrueHb values against the Sysmex values was found to be -0.02, with limits of agreement between -0.777 and 0.732 g/dL. Statistical analysis suggested good repeatability in results of TrueHb, having a low mean CV of 2.22, against 4.44, that of Sysmex values, and 95% confidence interval of 1.99-2.44, against 3.85-5.03, that of Sysmex values. These results suggested a strong positive correlation between the two measurements devices. It is thus concluded that TrueHb is a good point-of-care testing tool for estimating hemoglobin. © 2014 John Wiley & Sons Ltd.

  17. Compressed sensing for high-resolution nonlipid suppressed 1 H FID MRSI of the human brain at 9.4T.

    PubMed

    Nassirpour, Sahar; Chang, Paul; Avdievitch, Nikolai; Henning, Anke

    2018-04-29

    The aim of this study was to apply compressed sensing to accelerate the acquisition of high resolution metabolite maps of the human brain using a nonlipid suppressed ultra-short TR and TE 1 H FID MRSI sequence at 9.4T. X-t sparse compressed sensing reconstruction was optimized for nonlipid suppressed 1 H FID MRSI data. Coil-by-coil x-t sparse reconstruction was compared with SENSE x-t sparse and low rank reconstruction. The effect of matrix size and spatial resolution on the achievable acceleration factor was studied. Finally, in vivo metabolite maps with different acceleration factors of 2, 4, 5, and 10 were acquired and compared. Coil-by-coil x-t sparse compressed sensing reconstruction was not able to reliably recover the nonlipid suppressed data, rather a combination of parallel and sparse reconstruction was necessary (SENSE x-t sparse). For acceleration factors of up to 5, both the low-rank and the compressed sensing methods were able to reconstruct the data comparably well (root mean squared errors [RMSEs] ≤ 10.5% for Cre). However, the reconstruction time of the low rank algorithm was drastically longer than compressed sensing. Using the optimized compressed sensing reconstruction, acceleration factors of 4 or 5 could be reached for the MRSI data with a matrix size of 64 × 64. For lower spatial resolutions, an acceleration factor of up to R∼4 was successfully achieved. By tailoring the reconstruction scheme to the nonlipid suppressed data through parameter optimization and performance evaluation, we present high resolution (97 µL voxel size) accelerated in vivo metabolite maps of the human brain acquired at 9.4T within scan times of 3 to 3.75 min. © 2018 International Society for Magnetic Resonance in Medicine.

  18. Nonlinear Filtering and Approximation Techniques

    DTIC Science & Technology

    1991-09-01

    filtering. UNIT8 Q RECERCE**No 1223 Programme 5 A utomatique, Productique, Traitement dui Signal et des Donnc~es CONSISTENT PARAMETER ESTIMATION FOR...ue’e[71 E C 2.’(Rm x [0,7]; R) is the unique solution of the Hamilton-Jacobi-Bellman equation 9u,’[7](x, t) - EAu "’[ 7](x,t) + He,’[ 7](x,t,Du,[ 7](x,t

  19. Computer system for scanning tunneling microscope automation

    NASA Astrophysics Data System (ADS)

    Aguilar, M.; García, A.; Pascual, P. J.; Presa, J.; Santisteban, A.

    1987-03-01

    A computerized system for the automation of a scanning tunneling microscope is presented. It is based on an IBM personal computer (PC) either an XT or an AT, which performs the control, data acquisition and storage operations, displays the STM "images" in real time, and provides image processing tools for the restoration and analysis of data. It supports different data acquisition and control cards and image display cards. The software has been designed in a modular way to allow the replacement of these cards and other equipment improvements as well as the inclusion of user routines for data analysis.

  20. Open Quantum Systems and Classical Trajectories

    NASA Astrophysics Data System (ADS)

    Rebolledo, Rolando

    2004-09-01

    A Quantum Markov Semigroup consists of a family { T} = ({ T}t)_{t ∈ B R+} of normal ω*- continuous completely positive maps on a von Neumann algebra 𝔐 which preserve the unit and satisfy the semigroup property. This class of semigroups has been extensively used to represent open quantum systems. This article is aimed at studying the existence of a { T} -invariant abelian subalgebra 𝔄 of 𝔐. When this happens, the restriction of { T}t to 𝔄 defines a classical Markov semigroup T = (Tt)t ∈ ∝ + say, associated to a classical Markov process X = (Xt)t ∈ ∝ +. The structure (𝔄, T, X) unravels the quantum Markov semigroup { T} , providing a bridge between open quantum systems and classical stochastic processes.

  1. PREVAIL TRANSAPICAL: multicentre trial of transcatheter aortic valve implantation using the newly designed bioprosthesis (SAPIEN-XT) and delivery system (ASCENDRA-II).

    PubMed

    Walther, Thomas; Thielmann, Matthias; Kempfert, Joerg; Schroefel, Holger; Wimmer-Greinecker, Gerhard; Treede, Hendrik; Wahlers, Thorsten; Wendler, Olaf

    2012-08-01

    Transapical (TA) aortic valve implantation (AVI) has evolved as an alternative procedure for high-risk patients. We evaluated the second-generation SAPIEN XT™ prosthesis in a prospective multicentre clinical trial. A total of 150 patients (age: 81.6 ± 5.8 years; 40.7% female) were included. Prosthetic valves (diameter: 23 mm (n = 36), 26 mm (n = 57) and 29 mm (n = 57)) were implanted. The ASCENDRA-II™ modified delivery system was used in the smaller sizes. Mean logistic EuroSCORE was 24.3 ± 7.0%, and mean STS score 7.5 ± 4.4%. All patients gave written informed consent. Off-pump AVI was performed using femoral arterial and venous access wires as a safety net. All but two patients received TA-AVI, as planned. The 29-mm valve showed similar function as the values of two other diameters did. Three patients (2%) required temporary cardiopulmonary bypass support. Postoperative complications included renal failure requiring long-term dialysis in four, bleeding requiring rethoracotomy in four, respiratory complication requiring reintubation in eight and sepsis in four patients, respectively. Thirty-day mortality was 13 (8.7%) for the total cohort and 2/57 (3.5%) for patients receiving the 29-mm valve, respectively. Echocardiography at discharge showed none or trivial aortic incompetence (AI) in 71% and mild-AI in 22% of the patients. Post-implantation AI was predominantly paravalvular and ≥ 2+ in 7% of patients. One patient required reoperation for AI within 30 days. The PREVAIL TA multicentre trial demonstrates good functionality and good outcomes for TA-AVI, using the SAPIEN XT™ prosthesis and its second-generation ASCENDRA-II™ delivery system, as well successful introduction of the 29-mm SAPIEN XT™ valve for the benefit of high-risk elderly patients.

  2. 48 CFR 15.407-5 - Estimating systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Estimating systems. 15.407-5 Section 15.407-5 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES CONTRACTING BY NEGOTIATION Contract Pricing 15.407-5 Estimating systems. (a...

  3. 48 CFR 15.407-5 - Estimating systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Estimating systems. 15.407-5 Section 15.407-5 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES CONTRACTING BY NEGOTIATION Contract Pricing 15.407-5 Estimating systems. (a...

  4. 48 CFR 15.407-5 - Estimating systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Estimating systems. 15.407-5 Section 15.407-5 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES CONTRACTING BY NEGOTIATION Contract Pricing 15.407-5 Estimating systems. (a...

  5. 48 CFR 15.407-5 - Estimating systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Estimating systems. 15.407-5 Section 15.407-5 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES CONTRACTING BY NEGOTIATION Contract Pricing 15.407-5 Estimating systems. (a...

  6. Software Technology for Adaptable, Reliable Systems (STARS) (User Manual). Ada Command Environment (ACE) Version 8.0 Sun OS Implementation

    DTIC Science & Technology

    1990-10-29

    the equivalent type names in the basic X libary . 37. Intrinsics Contains the type declarations common to all Xt toolkit routines. 38. Widget-Package...Memory-Size constant Integer 1; MinInt constant I-reger Integer’First; MaxInt const-i’ integer Integer’Last; -- Max- Digits constant Integer 1; -- MaxMan...connection between some type names used by Xt routines and the equivalent type names in the basic X libary . .package RenamedXlibTypes is P;’ge 65 29

  7. System and method for constructing filters for detecting signals whose frequency content varies with time

    DOEpatents

    Qian, S.; Dunham, M.E.

    1996-11-12

    A system and method are disclosed for constructing a bank of filters which detect the presence of signals whose frequency content varies with time. The present invention includes a novel system and method for developing one or more time templates designed to match the received signals of interest and the bank of matched filters use the one or more time templates to detect the received signals. Each matched filter compares the received signal x(t) with a respective, unique time template that has been designed to approximate a form of the signals of interest. The robust time domain template is assumed to be of the order of w(t)=A(t)cos(2{pi}{phi}(t)) and the present invention uses the trajectory of a joint time-frequency representation of x(t) as an approximation of the instantaneous frequency function {phi}{prime}(t). First, numerous data samples of the received signal x(t) are collected. A joint time frequency representation is then applied to represent the signal, preferably using the time frequency distribution series. The joint time-frequency transformation represents the analyzed signal energy at time t and frequency f, P(t,f), which is a three-dimensional plot of time vs. frequency vs. signal energy. Then P(t,f) is reduced to a multivalued function f(t), a two dimensional plot of time vs. frequency, using a thresholding process. Curve fitting steps are then performed on the time/frequency plot, preferably using Levenberg-Marquardt curve fitting techniques, to derive a general instantaneous frequency function {phi}{prime}(t) which best fits the multivalued function f(t). Integrating {phi}{prime}(t) along t yields {phi}{prime}(t), which is then inserted into the form of the time template equation. A suitable amplitude A(t) is also preferably determined. Once the time template has been determined, one or more filters are developed which each use a version or form of the time template. 7 figs.

  8. SEI Software Engineering Education Directory.

    DTIC Science & Technology

    1987-02-01

    Software Design and Development Gilbert. Philip Systems: CDC Cyber 170/750 CDC Cyber 170760 DEC POP 11/44 PRIME AT&T 3B5 IBM PC IBM XT IBM RT...Macintosh VAx 8300 Software System Development and Laboratory CS 480/480L U P X T Textbooks: Software Design and Development Gilbert, Philip Systems: CDC...Acting Chair (618) 692-2386 Courses: Software Design and Development CS 424 U P E Y Textbooks: Software Design and Development, Gilbert, Philip Topics

  9. 46 CFR 111.105-5 - System integrity.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-5 System integrity. In order to maintain system integrity, each...

  10. 46 CFR 111.105-5 - System integrity.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-5 System integrity. In order to maintain system integrity, each...

  11. 46 CFR 111.105-5 - System integrity.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-5 System integrity. In order to maintain system integrity, each...

  12. Screening for ALK in non-small cell lung carcinomas: 5A4 and D5F3 antibodies perform equally well, but combined use with FISH is recommended.

    PubMed

    Savic, Spasenija; Diebold, Joachim; Zimmermann, Anne-Katrin; Jochum, Wolfram; Baschiera, Betty; Grieshaber, Susanne; Tornillo, Luigi; Bisig, Bettina; Kerr, Keith; Bubendorf, Lukas

    2015-08-01

    Immunohistochemistry (IHC) has become a promising method for pre-screening ALK-rearrangements in non-small cell lung carcinomas (NSCLC). Various ALK antibodies, detection systems and automated immunostainers are available. We therefore aimed to compare the performance of the monoclonal 5A4 (Novocastra, Leica) and D5F3 (Cell Signaling, Ventana) antibodies using two different immunostainers. Additionally we analyzed the accuracy of prospective ALK IHC-testing in routine diagnostics. Seventy-two NSCLC with available ALK FISH results and enriched for FISH-positive carcinomas were retrospectively analyzed. IHC was performed on BenchMarkXT (Ventana) using 5A4 and D5F3, respectively, and additionally with 5A4 on Bond-MAX (Leica). Data from our routine diagnostics on prospective ALK-testing with parallel IHC, using 5A4, and FISH were available from 303 NSCLC. All three IHC protocols showed congruent results. Only 1/25 FISH-positive NSCLC (4%) was false negative by IHC. For all three IHC protocols the sensitivity, specificity, positive (PPV) and negative predictive values (NPV) compared to FISH were 96%, 100%, 100% and 97.8%, respectively. In the prospective cohort 3/32 FISH-positive (9.4%) and 2/271 FISH-negative (0.7%) NSCLC were false negative and false positive by IHC, respectively. In routine diagnostics the sensitivity, specificity, PPV and NPV of IHC compared to FISH were 90.6%, 99.3%, 93.5% and 98.9%, respectively. 5A4 and D5F3 are equally well suited for detecting ALK-rearranged NSCLC. BenchMark and BOND-MAX immunostainers can be used for IHC with 5A4. True discrepancies between IHC and FISH results do exist and need to be addressed when implementing IHC in an ALK-testing algorithm. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. a Study of High Transition Temperature Superconductors: Mercury-Copper Oxide Systems

    NASA Astrophysics Data System (ADS)

    Kirven, Paul Douglas

    1995-01-01

    The Hg-based copper-oxides viz., HgBa _2Ca_{n-1}Cu_ nO _{2n+2+delta}, were discovered in 1993. A system consisting of many different, but related, compounds can be synthesized by including or substituting one or more elements in the original compound (e.g. Hg _{1-x}Pb_ x). In this thesis, the superconducting and normal state properties of several of these compounds were investigated. In the normal state electrical resistivity rho(T) is a linear function of temperature (T) and the magnetic susceptibility, X(T), is weakly paramagnetic. Many were observed to superconduct at very high temperatures. At 5 K up to 80% perfect diamagnetic X(T) was measured. The onset transition temperature (T_ c), where a specimen starts to superconduct, is observed to be as high as 135 K. Although T_ c is about 10 K higher than that of any previously known material, in many respects the properties of this new system are similar to that of other type II superconductors. Flux flow behavior and the nature of these type II superconductors was investigated via SQUID measurements and high field longitudinal magneto-resistance R(T,H) as a function of field and temperature. The study of flux motion allows one to observe Anderson-Kim type logarithimic flux creep at low temperature and field (T < 80K and B < 2T) and giant -flux flow at high temperature and field (80 < T < 130; B < 17T). Key parameters were determined. Some of which include reversibility temperature T*(H), critical field Hc, and pinning potential, Uo. Normal state properties which were also measured include the following: Curie constant, Curie-Weiss temperature (15-25 K), temperature independent susceptibility, and Sommerfeld constant (10-25 mJ/mol.Cu K^2). The values of these parameters of the Hg-based superconductors were compared to those of other superconductors. The results of this investigation are expected to yield a better understanding of this newest family of high temperature superconductors.

  14. Diffuse-interface polycrystal plasticity: expressing grain boundaries as geometrically necessary dislocations

    NASA Astrophysics Data System (ADS)

    Admal, Nikhil Chandra; Po, Giacomo; Marian, Jaime

    2017-12-01

    The standard way of modeling plasticity in polycrystals is by using the crystal plasticity model for single crystals in each grain, and imposing suitable traction and slip boundary conditions across grain boundaries. In this fashion, the system is modeled as a collection of boundary-value problems with matching boundary conditions. In this paper, we develop a diffuse-interface crystal plasticity model for polycrystalline materials that results in a single boundary-value problem with a single crystal as the reference configuration. Using a multiplicative decomposition of the deformation gradient into lattice and plastic parts, i.e. F( X,t)= F L( X,t) F P( X,t), an initial stress-free polycrystal is constructed by imposing F L to be a piecewise constant rotation field R 0( X), and F P= R 0( X)T, thereby having F( X,0)= I, and zero elastic strain. This model serves as a precursor to higher order crystal plasticity models with grain boundary energy and evolution.

  15. System control module diagnostic Expert Assistant

    NASA Technical Reports Server (NTRS)

    Flores, Luis M.; Hansen, Roger F.

    1990-01-01

    The Orbiter EXperiments (OEX) Program was established by NASA's Office of Aeronautics and Space Technology (OAST) to accomplish the precise data collection necessary to support a complete and accurate assessment of Space Transportation System (STS) Orbiter performance during all phases of a mission. During a mission, data generated by the various experiments are conveyed to the OEX System Control Module (SCM) which arranges for and monitors storage of the data on the OEX tape recorder. The SCM Diagnostic Expert Assistant (DEA) is an expert system which provides on demand advice to technicians performing repairs of a malfunctioning SCM. The DEA is a self-contained, data-driven knowledge-based system written in the 'C' Language Production System (CLIPS) for a portable micro-computer of the IBM PC/XT class. The DEA reasons about SCM hardware faults at multiple levels; the most detailed layer of encoded knowledge of the SCM is a representation of individual components and layouts of the custom-designed component boards.

  16. Infrared Measurement Variability Analysis.

    DTIC Science & Technology

    1980-09-01

    collecting optics of the measurement system. The first equation for tile blackbody experiment has the form 4.0 pim _ Ae W ,T) r(X,D) 3.5 pm - 4.0 pm JrD2 f3.5...potential for noise reduction by identifying and reducing contributing system effects. The measurement variance ott . of an infinite population of possible...irradiance can be written 4.0 pm I r()A A+ A ) 2 4.0 X C1(, = W(XT + AT)d 3.5 pim I since c + Af =2 r +Ar I Using the two expressions juSt devclopCd

  17. Comparison of Self-Etch Primers with Conventional Acid Etching System on Orthodontic Brackets

    PubMed Central

    Zope, Amit; Zope-Khalekar, Yogita; Chitko, Shrikant S.; Kerudi, Veerendra V.; Patil, Harshal Ashok; Jaltare, Pratik; Dolas, Siddhesh G

    2016-01-01

    Introduction The self-etching primer system consists of etchant and primer dispersed in a single unit. The etching and priming are merged as a single step leading to fewer stages in bonding procedure and reduction in the number of steps that also reduces the chance of introduction of error, resulting in saving time for the clinician. It also results in smaller extent of enamel decalcification. Aim To compare the Shear Bond Strength (SBS) of orthodontic bracket bonded with Self-Etch Primers (SEP) and conventional acid etching system and to study the surface appearance of teeth after debonding; etching with conventional acid etch and self-etch priming, using stereomicroscope. Materials and Methods Five Groups (n=20) were created randomly from a total of 100 extracted premolars. In a control Group A, etching of enamel was done with 37% phosphoric acid and bonding of stainless steel brackets with Transbond XT (3M Unitek, Monrovia, California). Enamel conditioning in left over four Groups was done with self-etching primers and adhesives as follows: Group B-Transbond Plus (3M Unitek), Group C Xeno V+ (Dentsply), Group D-G-Bond (GC), Group E-One-Coat (Coltene). The Adhesive Remnant Index (ARI) score was also evaluated. Additionally, the surface roughness using profilometer were observed. Results Mean SBS of Group A was 18.26±7.5MPa, Group B was 10.93±4.02MPa, Group C was 6.88±2.91MPa while of Group D was 7.78±4.13MPa and Group E was 10.39±5.22MPa respectively. In conventional group ARI scores shows that over half of the adhesive was remaining on the surface of tooth (score 1 to 3). In self-etching primer groups ARI scores show that there was no or minor amount of adhesive remaining on the surface of tooth (score 4 and 5). SEP produces a lesser surface roughness on the enamel than conventional etching. However, statistical analysis shows significant correlation (p<0.001) of bond strength with surface roughness of enamel. Conclusion All groups might show clinically

  18. 5 CFR 1330.403 - System certification.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 3 2013-01-01 2013-01-01 false System certification. 1330.403 Section....403 System certification. (a) The performance appraisal system(s) covering senior employees must be... certify an agency's appraisal system(s) only when a review of that system's design, application, and...

  19. 5 CFR 1330.403 - System certification.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 3 2014-01-01 2014-01-01 false System certification. 1330.403 Section....403 System certification. (a) The performance appraisal system(s) covering senior employees must be... certify an agency's appraisal system(s) only when a review of that system's design, application, and...

  20. A microcomputer interface for a digital audio processor-based data recording system.

    PubMed

    Croxton, T L; Stump, S J; Armstrong, W M

    1987-10-01

    An inexpensive interface is described that performs direct transfer of digitized data from the digital audio processor and video cassette recorder based data acquisition system designed by Bezanilla (1985, Biophys. J., 47:437-441) to an IBM PC/XT microcomputer. The FORTRAN callable software that drives this interface is capable of controlling the video cassette recorder and starting data collection immediately after recognition of a segment of previously collected data. This permits piecewise analysis of long intervals of data that would otherwise exceed the memory capability of the microcomputer.

  1. A microcomputer interface for a digital audio processor-based data recording system.

    PubMed Central

    Croxton, T L; Stump, S J; Armstrong, W M

    1987-01-01

    An inexpensive interface is described that performs direct transfer of digitized data from the digital audio processor and video cassette recorder based data acquisition system designed by Bezanilla (1985, Biophys. J., 47:437-441) to an IBM PC/XT microcomputer. The FORTRAN callable software that drives this interface is capable of controlling the video cassette recorder and starting data collection immediately after recognition of a segment of previously collected data. This permits piecewise analysis of long intervals of data that would otherwise exceed the memory capability of the microcomputer. PMID:3676444

  2. 36 CFR 212.5 - Road system management.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... safety or to environmental degradation. (c) Cost recovery on National Forest System roads. The Chief may... 36 Parks, Forests, and Public Property 2 2011-07-01 2011-07-01 false Road system management. 212.5... MANAGEMENT Administration of the Forest Transportation System § 212.5 Road system management. (a) Traffic...

  3. A microprocessor-based automation test system for the experiment of the multi-stage compressor

    NASA Astrophysics Data System (ADS)

    Zhang, Huisheng; Lin, Chongping

    1991-08-01

    An automation test system that is controlled by the microprocessor and used in the multistage compressor experiment is described. Based on the analysis of the compressor experiment performances, a complete hardware system structure is set up. It is composed of a IBM PC/XT computer, a large scale sampled data system, the moving machine with three directions, the scanners, the digital instrumentation and some output devices. A program structure of real-time software system is described. The testing results show that this test system can take the measure of many parameter magnitudes in the blade row places and on a boundary layer in different states. The automatic extent and the accuracy of experiment is increased and the experimental cost is reduced.

  4. Molecular Cloning and Functional Characterization of Xenopus tropicalis Frog Transient Receptor Potential Vanilloid 1 Reveal Its Functional Evolution for Heat, Acid, and Capsaicin Sensitivities in Terrestrial Vertebrates*

    PubMed Central

    Ohkita, Masashi; Saito, Shigeru; Imagawa, Toshiaki; Takahashi, Kenji; Tominaga, Makoto; Ohta, Toshio

    2012-01-01

    The functional difference of thermosensitive transient receptor potential (TRP) channels in the evolutionary context has attracted attention, but thus far little information is available on the TRP vanilloid 1 (TRPV1) function of amphibians, which diverged earliest from terrestrial vertebrate lineages. In this study we cloned Xenopus tropicalis frog TRPV1 (xtTRPV1), and functional characterization was performed using HeLa cells heterologously expressing xtTRPV1 (xtTRPV1-HeLa) and dorsal root ganglion neurons isolated from X. tropicalis (xtDRG neurons) by measuring changes in the intracellular calcium concentration ([Ca2+]i). The channel activity was also observed in xtTRPV1-expressing Xenopus oocytes. Furthermore, we tested capsaicin- and heat-induced nocifensive behaviors of the frog X. tropicalis in vivo. At the amino acid level, xtTRPV1 displays ∼60% sequence identity to other terrestrial vertebrate TRPV1 orthologues. Capsaicin induced [Ca2+]i increases in xtTRPV1-HeLa and xtDRG neurons and evoked nocifensive behavior in X. tropicalis. However, its sensitivity was extremely low compared with mammalian orthologues. Low extracellular pH and heat activated xtTRPV1-HeLa and xtDRG neurons. Heat also evoked nocifensive behavior. In oocytes expressing xtTRPV1, inward currents were elicited by heat and low extracellular pH. Mutagenesis analysis revealed that two amino acids (tyrosine 523 and alanine 561) were responsible for the low sensitivity to capsaicin. Taken together, our results indicate that xtTRPV1 functions as a polymodal receptor similar to its mammalian orthologues. The present study demonstrates that TRPV1 functions as a heat- and acid-sensitive channel in the ancestor of terrestrial vertebrates. Because it is possible to examine vanilloid and heat sensitivities in vitro and in vivo, X. tropicalis could be the ideal experimental lower vertebrate animal for the study of TRPV1 function. PMID:22130664

  5. Effect of a low-viscosity adhesive resin on the adhesion of metal brackets to enamel etched with hydrochloric or phosphoric acid combined with conventional adhesives.

    PubMed

    Yetkiner, Enver; Ozcan, Mutlu; Wegehaupt, Florian Just; Wiegand, Annette; Eden, Ece; Attin, Thomas

    2013-12-01

    This study investigated the effect of a low-viscosity adhesive resin (Icon) applied after either hydrochloric (HCl) or phosphoric acid (H3PO4) on the adhesion of metal brackets to enamel. Failure types were analyzed. The crowns of bovine incisors (N = 20) were sectioned mesio-distally and inciso-gingivally, then randomly assigned to 4 groups according to the following protocols to receive mandibular incisor brackets: 1) H3PO4 (37%)+TransbondXT (3M UNITEK); 2) H3PO4 (37%)+Icon+TransbondXT; 3) HCl (15%)+Icon (DMG)+TransbondXT 4) HCl (15%)+Icon+Heliobond (Ivoclar Vivadent)+TransbondXT. Specimens were stored in distilled water at 37°C for 24 h and thermocycled (5000x, 5°C to 55°C). The shear bond strength (SBS) test was performed using a universal testing machine (1 mm/min). Failure types were classified according to the Adhesive Remnant Index (ARI). Contact angles of adhesive resins were measured (n = 5 per adhesive) on ceramic surfaces. No significant difference in SBS was observed, implying no difference between combinations of adhesive resins and etching agents (p = 0.712; ANOVA). The Weibull distribution presented significantly lower Weibull modulus (m) of group 3 (m = 2.97) compared to other groups (m = 5.2 to 6.6) (p < 0.05). The mean SBS results (MPa) in descending order were as follows: group 4 (46.7 ± 10.3) > group 1 (45.4 ± 7.9) > group 2 (44.2 ± 10.6) > group 3 (42.6 ± 15.5). While in groups 1, 3, and 4 exclusively an ARI score of 0 (no adhesive left on tooth) was observed, in group 2, only one specimen demonstrated score 1 (less than half of adhesive left on tooth). Contact angle measurements were as follows: Icon (25.86 ± 3.81 degrees), Heliobond (31.98 ± 3.17 degrees), TransbondXT (35 ± 2.21 degrees). Icon can be safely used with the conventional adhesives tested on surfaces etched with either HCl or H3PO4.

  6. 44 CFR 334.5 - GMR system description.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 44 Emergency Management and Assistance 1 2014-10-01 2014-10-01 false GMR system description. 334.5 Section 334.5 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY PREPAREDNESS GRADUATED MOBILIZATION RESPONSE § 334.5 GMR system description. The GMR...

  7. Zonal Rate Model for Axial and Radial Flow Membrane Chromatography. Part I: Knowledge Transfer Across Operating Conditions and Scales

    PubMed Central

    Ghosh, Pranay; Vahedipour, Kaveh; Lin, Min; Vogel, Jens H; Haynes, Charles A; von Lieres, Eric

    2013-01-01

    The zonal rate model (ZRM) has previously been applied for analyzing the performance of axial flow membrane chromatography capsules by independently determining the impacts of flow and binding related non-idealities on measured breakthrough curves. In the present study, the ZRM is extended to radial flow configurations, which are commonly used at larger scales. The axial flow XT5 capsule and the radial flow XT140 capsule from Pall are rigorously analyzed under binding and non-binding conditions with bovine serum albumin (BSA) as test molecule. The binding data of this molecule is much better reproduced by the spreading model, which hypothesizes different binding orientations, than by the well-known Langmuir model. Moreover, a revised cleaning protocol with NaCl instead of NaOH and minimizing the storage time has been identified as most critical for quantitatively reproducing the measured breakthrough curves. The internal geometry of both capsules is visualized by magnetic resonance imaging (MRI). The flow in the external hold-up volumes of the XT140 capsule was found to be more homogeneous as in the previously studied XT5 capsule. An attempt for model-based scale-up was apparently impeded by irregular pleat structures in the used XT140 capsule, which might lead to local variations in the linear velocity through the membrane stack. However, the presented approach is universal and can be applied to different capsules. The ZRM is shown to potentially help save valuable material and time, as the experiments required for model calibration are much cheaper than the predicted large-scale experiment at binding conditions. Biotechnol. Bioeng. 2013; 110: 1129–1141. © 2012 Wiley Periodicals, Inc. PMID:23097218

  8. Polishing and toothbrushing alters the surface roughness and gloss of composite resins.

    PubMed

    Kamonkhantikul, Krid; Arksornnukit, Mansuang; Takahashi, Hidekazu; Kanehira, Masafumi; Finger, Werner J

    2014-01-01

    This study aimed to investigate the surface roughness and gloss of composite resins after using two polishing systems and toothbrushing. Six composite resins (Durafill VS, Filtek Z250, Filtek Z350 XT, Kalore, Venus Diamond, and Venus Pearl) were evaluated after polishing with two polishing systems (Sof-Lex, Venus Supra) and after toothbrushing up to 40,000 cycles. Surface roughness (Ra) and gloss were determined for each composite resin group (n=6) after silicon carbide paper grinding, polishing, and toothbrushing. Two-way ANOVA indicated significant differences in both Ra and gloss between measuring stages for the composite resins tested, except Venus Pearl, which showed significant differences only in gloss. After polishing, the Filtek Z350 XT, Kalore, and Venus Diamond showed significant increases in Ra, while all composite resin groups except the Filtek Z350 XT and Durafill VS with Sof-Lex showed increases in gloss. After toothbrushing, all composite resin demonstrated increases in Ra and decreases in gloss.

  9. 46 CFR 62.25-5 - All control systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false All control systems. 62.25-5 Section 62.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-5 All control systems. (a) Local and remote...

  10. Effect of changes to the manufacturer application techniques 
on the shear bond strength of simplified dental adhesives.

    PubMed

    Chasqueira, Ana Filipa; Arantes-Oliveira, Sofia; Portugal, Jaime

    2013-09-13

    The aim of this work was to assess the shear bond strength (SBS) between a composite resin and dentin, promoted by two dental adhesive systems (one-step self-etching adhesive Easy Bond [3M ESPE], and two-step etch-and-rinse adhesive Scotchbond 1XT [3M ESPE]) with different application protocols (per manufacturer's instruction (control group); with one to four additional adhesive layers; or with an extra hydrophobic adhesive layer). Proximal enamel was removed from ninety caries-free human molars to obtain two dentin discs per tooth, which were randomly assigned to twelve experimental groups (n=15). After adhesion protocol, the composite resin (Filtek Z250 [3M ESPE]) was applied. Specimens were mounted in the Watanabe test device and shear bond test was performed in a universal testing machine with a crosshead speed of 5 mm/min. Data were analyzed with ANOVA followed by Student-Newman-Keuls tests (P<0.05). The highest SBS mean value was attained with the Easy Bond three layers group (41.23±2.71 MPa) and the lowest with Scotchbond 1XT per manufacturer's instructions (27.15±2.99 MPa). Easy Bond yielded higher SBS values than Scotchbond 1XT. There were no statistically significant differences (P>0.05) between the application protocols tested, except for the three and four layers groups, that presented higher SBS results compared to manufacturer's instruction groups (P<0.05). No statistically significant differences were detected between the three and four layers groups (P≥0.05). It is recommendable to apply three adhesive layers when using Easy Bond and Scotchbond 1XT adhesives, since it improves SBS values without consuming much time.

  11. The 5-kwe reactor thermoelectric system summary

    NASA Technical Reports Server (NTRS)

    Vanosdol, J. H. (Editor)

    1973-01-01

    Design of the 5-kwe reactor thermoelectric system was initiated in February 1972 and extended through the conceptual design phase into the preliminary design phase. Design effort was terminated in January, 1973. This report documents the system and component requirements, design approaches, and performance and design characteristics for the 5-kwe system. Included is summary information on the reactor, radiation shields, power conversion systems, thermoelectric pump, radiator/structure, liquid metal components, and the control system.

  12. 10 CFR 960.5-1 - System guidelines.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false System guidelines. 960.5-1 Section 960.5-1 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5-1 System guidelines. (a) Qualifying conditions—(1) Preclosure...

  13. 10 CFR 960.5-1 - System guidelines.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false System guidelines. 960.5-1 Section 960.5-1 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5-1 System guidelines. (a) Qualifying conditions—(1) Preclosure...

  14. 10 CFR 960.5-1 - System guidelines.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false System guidelines. 960.5-1 Section 960.5-1 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5-1 System guidelines. (a) Qualifying conditions—(1) Preclosure...

  15. Comparing the Performance of Blue Gene/Q with Leading Cray XE6 and InfiniBand Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerbyson, Darren J.; Barker, Kevin J.; Vishnu, Abhinav

    2013-01-21

    Abstract—Three types of systems dominate the current High Performance Computing landscape: the Cray XE6, the IBM Blue Gene, and commodity clusters using InfiniBand. These systems have quite different characteristics making the choice for a particular deployment difficult. The XE6 uses Cray’s proprietary Gemini 3-D torus interconnect with two nodes at each network endpoint. The latest IBM Blue Gene/Q uses a single socket integrating processor and communication in a 5-D torus network. InfiniBand provides the flexibility of using nodes from many vendors connected in many possible topologies. The performance characteristics of each vary vastly along with their utilization model. In thismore » work we compare the performance of these three systems using a combination of micro-benchmarks and a set of production applications. In particular we discuss the causes of variability in performance across the systems and also quantify where performance is lost using a combination of measurements and models. Our results show that significant performance can be lost in normal production operation of the Cray XT6 and InfiniBand Clusters in comparison to Blue Gene/Q.« less

  16. 46 CFR 62.25-5 - All control systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... normal operation. (c) Inadvertent grounding of an electrical or electronic safety control system must not... 46 Shipping 2 2014-10-01 2014-10-01 false All control systems. 62.25-5 Section 62.25-5 Shipping... General Requirements for All Automated Vital Systems § 62.25-5 All control systems. (a) Local and remote...

  17. 46 CFR 62.25-5 - All control systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... normal operation. (c) Inadvertent grounding of an electrical or electronic safety control system must not... 46 Shipping 2 2012-10-01 2012-10-01 false All control systems. 62.25-5 Section 62.25-5 Shipping... General Requirements for All Automated Vital Systems § 62.25-5 All control systems. (a) Local and remote...

  18. 46 CFR 62.25-5 - All control systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... normal operation. (c) Inadvertent grounding of an electrical or electronic safety control system must not... 46 Shipping 2 2013-10-01 2013-10-01 false All control systems. 62.25-5 Section 62.25-5 Shipping... General Requirements for All Automated Vital Systems § 62.25-5 All control systems. (a) Local and remote...

  19. 46 CFR 62.25-5 - All control systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... normal operation. (c) Inadvertent grounding of an electrical or electronic safety control system must not... 46 Shipping 2 2011-10-01 2011-10-01 false All control systems. 62.25-5 Section 62.25-5 Shipping... General Requirements for All Automated Vital Systems § 62.25-5 All control systems. (a) Local and remote...

  20. 5 CFR 430.403 - System certification.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false System certification. 430.403 Section 430... MANAGEMENT Performance Appraisal Certification for Pay Purposes § 430.403 System certification. (a) The performance appraisal system(s) covering senior employees must be certified by OPM, with OMB concurrence, as...

  1. 5 CFR 430.403 - System certification.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false System certification. 430.403 Section 430... MANAGEMENT Performance Appraisal Certification for Pay Purposes § 430.403 System certification. (a) The performance appraisal system(s) covering senior employees must be certified by OPM, with OMB concurrence, as...

  2. 5 CFR 430.403 - System certification.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false System certification. 430.403 Section 430... MANAGEMENT Performance Appraisal Certification for Pay Purposes § 430.403 System certification. (a) The performance appraisal system(s) covering senior employees must be certified by OPM, with OMB concurrence, as...

  3. Investigation of Performance of Axial-Flow Compressor of XT-46 Turbine-Propeller Engine. II - Performance of Revised Compressor at Design Equivalent Speed. II; Performance of Revised Compressor at Design Equivalent Speed

    NASA Technical Reports Server (NTRS)

    Creagh, John W. R.

    1950-01-01

    The compressor from the XT-46 turbine-propeller engine was revised by removing the last two rows of stator blades and by eliminating the interstage leakage paths described in a previous report. With the revised compressor, the flow choking point shifted upstream into the last rotor-blade row but the maximum weight flow was not increased over that of the original compressor. The flow range of the revised compressor was reduced to about two-thirds that obtained with the original compressor. The later stages of the compressor did not produce the design static-pressure increase probably because of excessive boundary-layer build-up in this region. Measurements obtained in the ninth-stage stator showed that the performance up to this station was promising but that the last three stages of the compressor were limiting the useful operating range of the preceding stages. Some modifications in flow-passage geometry and blade settings are believed to be necessary, however, before any major improvements in over-all compressor performance can be obtained.

  4. The GEOS-5 Data Assimilation System-Documentation of Versions 5.0.1, 5.1.0, and 5.2.0

    NASA Technical Reports Server (NTRS)

    Suarez, Max J.; Rienecker, M. M.; Todling, R.; Bacmeister, J.; Takacs, L.; Liu, H. C.; Gu, W.; Sienkiewicz, M.; Koster, R. D.; Gelaro, R.; hide

    2008-01-01

    This report documents the GEOS-5 global atmospheric model and data assimilation system (DAS), including the versions 5.0.1, 5.1.0, and 5.2.0, which have been implemented in products distributed for use by various NASA instrument team algorithms and ultimately for the Modem Era Retrospective analysis for Research and Applications (MERRA). The DAS is the integration of the GEOS-5 atmospheric model with the Gridpoint Statistical Interpolation (GSI) Analysis, a joint analysis system developed by the NOAA/National Centers for Environmental Prediction and the NASA/Global Modeling and Assimilation Office. The primary performance drivers for the GEOS DAS are temperature and moisture fields suitable for the EOS instrument teams, wind fields for the transport studies of the stratospheric and tropospheric chemistry communities, and climate-quality analyses to support studies of the hydrological cycle through MERRA. The GEOS-5 atmospheric model has been approved for open source release and is available from: http://opensource.gsfc.nasa.gov/projects/GEOS-5/GEOS-5.php.

  5. A Next-Generation Parallel File System Environment for the OLCF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dillow, David A; Fuller, Douglas; Gunasekaran, Raghul

    2012-01-01

    When deployed in 2008/2009 the Spider system at the Oak Ridge National Laboratory s Leadership Computing Facility (OLCF) was the world s largest scale Lustre parallel file system. Envisioned as a shared parallel file system capable of delivering both the bandwidth and capacity requirements of the OLCF s diverse computational environment, Spider has since become a blueprint for shared Lustre environments deployed worldwide. Designed to support the parallel I/O requirements of the Jaguar XT5 system and other smallerscale platforms at the OLCF, the upgrade to the Titan XK6 heterogeneous system will begin to push the limits of Spider s originalmore » design by mid 2013. With a doubling in total system memory and a 10x increase in FLOPS, Titan will require both higher bandwidth and larger total capacity. Our goal is to provide a 4x increase in total I/O bandwidth from over 240GB=sec today to 1TB=sec and a doubling in total capacity. While aggregate bandwidth and total capacity remain important capabilities, an equally important goal in our efforts is dramatically increasing metadata performance, currently the Achilles heel of parallel file systems at leadership. We present in this paper an analysis of our current I/O workloads, our operational experiences with the Spider parallel file systems, the high-level design of our Spider upgrade, and our efforts in developing benchmarks that synthesize our performance requirements based on our workload characterization studies.« less

  6. Effects of Different Combinations of Er:YAG Laser-Adhesives on Enamel Demineralization and Bracket Bond Strength.

    PubMed

    Çokakoğlu, Serpil; Nalçacı, Ruhi; Üşümez, Serdar; Malkoç, Sıddık

    2016-04-01

    The purpose of this study was to investigate the demineralization around brackets and shear bond strength (SBS) of brackets bonded to Er:YAG laser-irradiated enamel at different power settings with various adhesive systems combinations. A total of 108 premolar teeth were used in this study. Teeth were assigned into three groups according to the etching procedure, then each group divided into three subgroups based on the application of different adhesive systems. There were a total of nine groups as follows. Group 1: Acid + Transbond XT Primer; group 2: Er:YAG (100 mJ, 10 Hz) etching + Transbond XT Primer; group 3: Er:YAG (200 mJ, 10 Hz) etching + Transbond XT Primer; group 4: Transbond Plus self-etching primer (SEP); group 5: Er:YAG (100 mJ, 10 Hz) etching + Transbond Plus SEP; group 6: Er:YAG (200 mJ, 10 Hz) etching + Transbond Plus SEP; group 7: Clearfil Protect Bond; group 8: Er:YAG (100 mJ, 10 Hz) etching + Clearfil Protect Bond; group 9: Er:YAG (200 mJ, 10 Hz) etching + Clearfil Protect Bond. Brackets were bonded with Transbond XT Adhesive Paste in all groups. Teeth to be evaluated for demineralization and SBS were exposed to pH and thermal cyclings, respectively. Then, demineralization samples were scanned with micro-CT to determine lesion depth values. For SBS test, a universal testing machine was used and adhesive remnant was index scored after debonding. Data were analyzed statistically. No significant differences were found among the lesion depth values of the various groups, except for G7 and G8, in which the lowest values were recorded. The lowest SBS values were in G7, whereas the highest were in G9. The differences between the other groups were not significant. Er:YAG laser did not have a positive effect on prevention of enamel demineralization. When two step self-etch adhesive is preferred for bonding brackets, laser etching at 1 W (100 mJ, 10 Hz) is suggested to improve SBS of brackets.

  7. 5 CFR 10.2 - Accountability systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Accountability systems. 10.2 Section 10.2 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE RULES AGENCY ACCOUNTABILITY SYSTEMS; OPM AUTHORITY TO REVIEW PERSONNEL MANAGEMENT PROGRAMS (RULE X) § 10.2 Accountability systems. The Director of...

  8. 5 CFR 10.2 - Accountability systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Accountability systems. 10.2 Section 10.2 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE RULES AGENCY ACCOUNTABILITY SYSTEMS; OPM AUTHORITY TO REVIEW PERSONNEL MANAGEMENT PROGRAMS (RULE X) § 10.2 Accountability systems. The Director of...

  9. 5 CFR 10.2 - Accountability systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Accountability systems. 10.2 Section 10.2 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE RULES AGENCY ACCOUNTABILITY SYSTEMS; OPM AUTHORITY TO REVIEW PERSONNEL MANAGEMENT PROGRAMS (RULE X) § 10.2 Accountability systems. The Director of...

  10. 46 CFR 111.105-5 - System integrity.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL... individual electrical installation in a hazardous location must comply specifically with Articles 500-505 of...

  11. Mirror Technology Development for the International X-ray Observatory Mission

    DTIC Science & Technology

    2010-06-06

    Solar Panels E xt en si bl e O pt ic al B en ch Focal plane assembly Mirror Assembly ESA JAXA NASA Will Zhang Mirror Tech Days...0.1 m2 0.5 arcsecs 0.4 m2 15 arcsecs 0.2 m2 120 arcsecs St at e of th e A rt IXO Requirement 3 m2 5 arcsecs Will Zhang Mirror...QED Technologies, Rochester, NY Rodriguez Precision Optics, Gonzales, LA Dallas Optical Systems, Inc., Rockwall, TX RAPT Industries, Inc., Freemont

  12. Investigation of Performance of Axial-Flow Compressor of XT-46 Turbine-Propeller Engine. I - Preliminary Investigation at 50-,70-, and 100-Percent Design Equivalent Speed

    NASA Technical Reports Server (NTRS)

    Creagh, John W.R.; Sandercrock, Donald M.

    1950-01-01

    An investigation is being conducted to determine the performance of the 12-stage axial-flow compressor of the XT-46 turbine-propeller engine. This compressor was designed to produce a pressure ratio of 9 at an adiabatic efficiency of 0.86. The design pressure ratios per stage were considerably greater than any employed in current aircraft gas-turbine engines using this type of compressor. The compressor performance was evaluated at two stations. The station near the entrance section of the combustors indicated a peak pressure ratio of 6.3 at an adiabatic efficiency of 0.63 for a corrected weight flow of 23.1 pounds per second. The other, located one blade-chord downstream of the last stator row, indicated a peak pressure ratio of 6.97 at an adiabatic efficiency of 0.81 for a corrected weight flow of 30.4 pounds per second. The difference in performance obtained at the two stations is attributed to shock waves in the vicinity of the last stator row. These shock waves and the accompanying flow choking, together with interstage circulatory flows, shift the compressor operating curves into the region where surge would normally occur. The inability of the compressor to meet design pressure ratio is probably due to boundary-layer buildup in the last stages, which cause axial velocities greater than design values that, in turn, adversely affect the angles of attack and turning angles in these blade rows.

  13. 19 CFR 143.5 - System performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 2 2012-04-01 2012-04-01 false System performance requirements. 143.5 Section 143.5 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF... must demonstrate that his system can interface directly with the Customs computer and ensure accurate...

  14. 19 CFR 143.5 - System performance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 2 2011-04-01 2011-04-01 false System performance requirements. 143.5 Section 143.5 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF... must demonstrate that his system can interface directly with the Customs computer and ensure accurate...

  15. 19 CFR 143.5 - System performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 2 2014-04-01 2014-04-01 false System performance requirements. 143.5 Section 143.5 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF... must demonstrate that his system can interface directly with the Customs computer and ensure accurate...

  16. 19 CFR 143.5 - System performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false System performance requirements. 143.5 Section 143.5 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF... must demonstrate that his system can interface directly with the Customs computer and ensure accurate...

  17. 19 CFR 143.5 - System performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 2 2013-04-01 2013-04-01 false System performance requirements. 143.5 Section 143.5 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF... must demonstrate that his system can interface directly with the Customs computer and ensure accurate...

  18. Effect of randomness in logistic maps

    NASA Astrophysics Data System (ADS)

    Khaleque, Abdul; Sen, Parongama

    2015-01-01

    We study a random logistic map xt+1 = atxt[1 - xt] where at are bounded (q1 ≤ at ≤ q2), random variables independently drawn from a distribution. xt does not show any regular behavior in time. We find that xt shows fully ergodic behavior when the maximum allowed value of at is 4. However , averaged over different realizations reaches a fixed point. For 1 ≤ at ≤ 4, the system shows nonchaotic behavior and the Lyapunov exponent is strongly dependent on the asymmetry of the distribution from which at is drawn. Chaotic behavior is seen to occur beyond a threshold value of q1(q2) when q2(q1) is varied. The most striking result is that the random map is chaotic even when q2 is less than the threshold value 3.5699⋯ at which chaos occurs in the nonrandom map. We also employ a different method in which a different set of random variables are used for the evolution of two initially identical x values, here the chaotic regime exists for all q1 ≠ q2 values.

  19. Teaching and Coaching Tennis Using System 5

    ERIC Educational Resources Information Center

    Helfrich, Janet

    2006-01-01

    The United States Professional Tennis Association (USPTA) has developed a universal language for tennis instruction entitled System 5: The Five Keys to Tennis, which is extremely easy to teach and learn and covers court positioning, strategy, and stroke selection. Many professional tennis instructors have used System 5 since its inception but…

  20. Thermodynamic Database for the NdO(1.5)-YO(1.5)-YbO(1.5)-ScO(1.5)-ZrO2 System

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Copland, Evan H.; Kaufman, Larry

    2001-01-01

    A database for YO(1.5)-NdO(1.5)-YbO(1.5)-ScO(1.5)-ZrO2 for ThermoCalc (ThermoCalc AB, Stockholm, Sweden) has been developed. The basis of this work is the YO(1.5)-ZrO2 assessment by Y. Du, Z. Jin, and P. Huang, 'Thermodynamic Assessment of the ZrO2-YO(1.5) System'. Experimentally only the YO(1.5)-ZrO2 system has been well-studied. All other systems are only approximately known. The major simplification in this work is the treatment of each single cation unit as a component. The pure liquid oxides are taken as reference states and two term lattice stability descriptions are used for each of the components. The limited experimental phase diagrams are reproduced.

  1. Long-time behavior for suspension bridge equations with time delay

    NASA Astrophysics Data System (ADS)

    Park, Sun-Hye

    2018-04-01

    In this paper, we consider suspension bridge equations with time delay of the form u_{tt}(x,t) + Δ ^2 u (x,t) + k u^+ (x,t) + a_0 u_t (x,t) + a_1 u_t (x, t- τ ) + f(u(x,t)) = g(x). Many researchers have studied well-posedness, decay rates of energy, and existence of attractors for suspension bridge equations without delay effects. But, as far as we know, there is no work about suspension equations with time delay. In addition, there are not many studies on attractors for other delayed systems. Thus we first provide well-posedness for suspension equations with time delay. And then show the existence of global attractors and the finite dimensionality of the attractors by establishing energy functionals which are related to the norm of the phase space to our problem.

  2. Evaluation and optimisation of preparative semi-automated electrophoresis systems for Illumina library preparation.

    PubMed

    Quail, Michael A; Gu, Yong; Swerdlow, Harold; Mayho, Matthew

    2012-12-01

    Size selection can be a critical step in preparation of next-generation sequencing libraries. Traditional methods employing gel electrophoresis lack reproducibility, are labour intensive, do not scale well and employ hazardous interchelating dyes. In a high-throughput setting, solid-phase reversible immobilisation beads are commonly used for size-selection, but result in quite a broad fragment size range. We have evaluated and optimised the use of two semi-automated preparative DNA electrophoresis systems, the Caliper Labchip XT and the Sage Science Pippin Prep, for size selection of Illumina sequencing libraries. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Shear Bond Strength of Three Orthodontic Bonding Systems on Enamel and Restorative Materials

    PubMed Central

    Ebeling, Jennifer; Schauseil, Michael; Stein, Steffen; Roggendorf, Matthias; Korbmacher-Steiner, Heike

    2016-01-01

    Objective. The aim of this in vitro study was to determine the shear bond strength (SBS) and adhesive remnant index (ARI) score of two self-etching no-mix adhesives (iBond™ and Scotchbond™) on different prosthetic surfaces and enamel, in comparison with the commonly used total etch system Transbond XT™. Materials and Methods. A total of 270 surfaces (1 enamel and 8 restorative surfaces, n = 30) were randomly divided into three adhesive groups. In group 1 (control) brackets were bonded with Transbond XT primer. In the experimental groups iBond adhesive (group 2) and Scotchbond Universal adhesive (group 3) were used. The SBS was measured using a Zwicki 1120™ testing machine. The ARI and SBS were compared statistically using the Kruskal–Wallis test (P ≤ 0.05). Results. Significant differences in SBS and ARI were found between the control group and experimental groups. Conclusions. Transbond XT showed the highest SBS on human enamel. Scotchbond Universal on average provides the best bonding on all other types of surface (metal, composite, and porcelain), with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures on restorative materials in patients. If metal brackets have to be bonded to a metal surface, the use of a dual-curing resin is recommended. PMID:27738633

  4. Linux Kernel Co-Scheduling and Bulk Synchronous Parallelism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Terry R

    2012-01-01

    This paper describes a kernel scheduling algorithm that is based on coscheduling principles and that is intended for parallel applications running on 1000 cores or more. Experimental results for a Linux implementation on a Cray XT5 machine are presented. The results indicate that Linux is a suitable operating system for this new scheduling scheme, and that this design provides a dramatic improvement in scaling performance for synchronizing collective operations at scale.

  5. Surface roughness of novel resin composites polished with one-step systems.

    PubMed

    Ergücü, Z; Türkün, L S

    2007-01-01

    This study: 1) analyzed the surface roughness of five novel resin composites that contain nanoparticles after polishing with three different one-step systems and 2) evaluated the effectiveness of these polishers and their possible surface damage using scanning electron microscope (SEM) analysis. The resin composites evaluated in this study include CeramX, Filtek Supreme XT, Grandio, Premise and Tetric EvoCeram. A total of 100 discs (20/resin composites, 10 x 2 mm) were fabricated. Five specimens/resin composites cured under Mylar strips served as the control. The samples were polished for 30 seconds with PoGo, OptraPol and One Gloss discs at 15,000 rpm using a slow speed handpiece. The surfaces were tested for roughness (Ra) with a surface roughness tester and examined with SEM. One-way ANOVA was used for statistical analysis (p = 0.05). For all the composites tested, differences between the polishing systems were found to be significant (p < 0.05). For Filtek Supreme XT, Mylar and PoGo created equally smooth surfaces, while significantly rougher surfaces were obtained after OptraPol and One Gloss applications. For Grandio, Mylar and PoGo created equally smooth surfaces, while OptraPol and One Gloss produced equally rougher surfaces. Tetric EvoCeram exhibited the roughest surface with OptraPol, while no significant differences were found between Premise and CeramX. According to SEM images, OptraPol and One Gloss scratched and plucked the particles away from the surface, while PoGo created a uniform finish, although the roughness values were not the same for each composite. Effectiveness of the polishers seems to be material dependent.

  6. DNA Sequence Modulates Geometrical Isomerism of the trans-8,9-Dihydro-8-(2,6-diamino-4-oxo-3,4-dihydropyrimid-5-yl-formamido)-9-hydroxy Aflatoxin B1 Adduct

    PubMed Central

    2016-01-01

    Aflatoxin B1 (AFB1), a mycotoxin produced by Aspergillus flavus, is oxidized by cytochrome P450 enzymes to aflatoxin B1-8,9-epoxide, which alkylates DNA at N7-dG. Under basic conditions, this N7-dG adduct rearranges to yield the trans-8,9-dihydro-8-(2,6-diamino-4-oxo-3,4-dihydropyrimid-5-yl-formamido)-9-hydroxy aflatoxin B1 (AFB1–FAPY) adduct. The AFB1–FAPY adduct exhibits geometrical isomerism involving the formamide moiety. NMR analyses of duplex oligodeoxynucleotides containing the 5′-XA-3′, 5′-XC-3′, 5′-XT-3′, and 5′-XY-3′ sequences (X = AFB1–FAPY; Y = 7-deaza-dG) demonstrate that the equilibrium between E and Z isomers is controlled by major groove hydrogen bonding interactions. Structural analysis of the adduct in the 5′-XA-3′ sequence indicates the preference of the E isomer of the formamide group, attributed to formation of a hydrogen bond between the formyl oxygen and the N6 exocyclic amino group of the 3′-neighbor adenine. While the 5′-XA-3′ sequence exhibits the E isomer, the 5′-XC-3′ sequence exhibits a 7:3 E:Z ratio at equilibrium at 283 K. The E isomer is favored by a hydrogen bond between the formyl oxygen and the N4-dC exocyclic amino group of the 3′-neighbor cytosine. The 5′-XT-3′ and 5′-XY-3′ sequences cannot form such a hydrogen bond between the formyl oxygen and the 3′-neighbor T or Y, respectively, and in these sequence contexts the Z isomer is favored. Additional equilibria between α and β anomers and the potential to exhibit atropisomers about the C5–N5 bond do not depend upon sequence. In each of the four DNA sequences, the AFB1–FAPY adduct maintains the β deoxyribose configuration. Each of these four sequences feature the atropisomer of the AFB1 moiety that is intercalated above the 5′-face of the damaged guanine. This enforces the Ra axial conformation for the C5–N5 bond. PMID:25587868

  7. DNA Sequence Modulates Geometrical Isomerism of the trans-8,9- Dihydro-8-(2,6-diamino-4-oxo-3,4-dihydropyrimid-5-yl-formamido)- 9-hydroxy Aflatoxin B1 Adduct.

    PubMed

    Li, Liang; Brown, Kyle L; Ma, Ruidan; Stone, Michael P

    2015-02-16

    Aflatoxin B(1) (AFB(1)), a mycotoxin produced by Aspergillus flavus, is oxidized by cytochrome P450 enzymes to aflatoxin B(1)-8,9-epoxide, which alkylates DNA at N7-dG. Under basic conditions, this N7-dG adduct rearranges to yield the trans-8,9-dihydro-8-(2,6-diamino-4-oxo-3,4-dihydropyrimid-5-yl-formamido)-9-hydroxy aflatoxin B(1) (AFB(1)−FAPY) adduct. The AFB(1)−FAPY adduct exhibits geometrical isomerism involving the formamide moiety. NMR analyses of duplex oligodeoxynucleotides containing the 5′-XA-3′, 5′-XC-3′, 5′-XT-3′, and 5′-XY-3′ sequences (X = AFB(1)−FAPY; Y = 7-deaza-dG)demonstrate that the equilibrium between E and Z isomers is controlled by major groove hydrogen bonding interactions.Structural analysis of the adduct in the 5′-XA-3′ sequence indicates the preference of the E isomer of the formamide group,attributed to formation of a hydrogen bond between the formyl oxygen and the N(6) exocyclic amino group of the 3′-neighboradenine. While the 5′-XA-3′ sequence exhibits the E isomer, the 5′-XC-3′ sequence exhibits a 7:3 E:Z ratio at equilibrium at 283K. The E isomer is favored by a hydrogen bond between the formyl oxygen and the N(4)-dC exocyclic amino group of the 3′-neighbor cytosine. The 5′-XT-3′ and 5′-XY-3′ sequences cannot form such a hydrogen bond between the formyl oxygen and the 3′-neighbor T or Y, respectively, and in these sequence contexts the Z isomer is favored. Additional equilibria between α and β anomers and the potential to exhibit atropisomers about the C5−N(5) bond do not depend upon sequence. In each of the four DNA sequences, the AFB(1)−FAPY adduct maintains the β deoxyribose configuration. Each of these four sequences feature the atropisomer of the AFB(1) moiety that is intercalated above the 5′-face of the damaged guanine. This enforces the Ra axialc onformation for the C5−N(5) bond.

  8. Changes in haematology measurements with the Sysmex XT-2000iV during storage of feline blood sampled in EDTA or EDTA plus CTAD.

    PubMed

    Granat, Fanny; Geffré, Anne; Bourgès-Abella, Nathalie; Braun, Jean-Pierre; Trumel, Catherine

    2013-06-01

    In veterinary medicine a complete blood cell count (CBC) cannot always be performed within 24 h as usually recommended, particularly for specimens shipped to a reference laboratory. This raises the question of the stability of the variables, especially in ethylenediamine tetra-acetic acid (EDTA) feline blood specimens, known to be prone to in vitro platelet aggregation. Citrate, theophylline, adenosine and dipyridamole (CTAD) has been reported to limit platelet aggregation in feline blood specimens. The aim of this study was to measure the stability of the haematological variables and the platelet aggregation score in EDTA and EDTA plus CTAD (EDCT) feline blood specimens during 48 h of storage at room temperature. Forty-six feline EDTA and EDCT blood specimens were analysed with a Sysmex XT-2000iV analyser, and the platelet count and score of platelet aggregation were estimated immediately and after 24 and 48 h of storage. A significant increase in mean corpuscular volume, haematocrit, reticulocyte and eosinophil counts, and a significant decrease in mean corpuscular haemoglobin concentration and monocyte count were observed. Haemoglobin, mean corpuscular haemoglobin, and red blood cell, white blood cell, neutrophil and lymphocyte counts remained stable. Changes in reticulocyte indexes with time (low fluorescence ratio, medium fluorescence ratio, high fluorescence ratio and immature reticulocyte fraction) were not significant. Changes were generally more pronounced in EDTA than in EDCT. Platelet aggregation decreased markedly in initially highly aggregated EDTA specimens, and increased slightly in initially non- or mildly-aggregated EDTA or EDCT specimens. Platelet counts increased and decreased, or remained stable, respectively. CTAD can reduce storage-induced changes of the haematological variables in feline samples, thus improving the reliability of a CBC and limiting clinical misinterpretations.

  9. Aircraft noise prediction program propeller analysis system IBM-PC version user's manual version 2.0

    NASA Technical Reports Server (NTRS)

    Nolan, Sandra K.

    1988-01-01

    The IBM-PC version of the Aircraft Noise Prediction Program (ANOPP) Propeller Analysis System (PAS) is a set of computational programs for predicting the aerodynamics, performance, and noise of propellers. The ANOPP-PAS is a subset of a larger version of ANOPP which can be executed on CDC or VAX computers. This manual provides a description of the IBM-PC version of the ANOPP-PAS and its prediction capabilities, and instructions on how to use the system on an IBM-XT or IBM-AT personal computer. Sections within the manual document installation, system design, ANOPP-PAS usage, data entry preprocessors, and ANOPP-PAS functional modules and procedures. Appendices to the manual include a glossary of ANOPP terms and information on error diagnostics and recovery techniques.

  10. 46 CFR 58.60-5 - Industrial systems: Locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Industrial systems: Locations. 58.60-5 Section 58.60-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU...

  11. 46 CFR 58.60-5 - Industrial systems: Locations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Industrial systems: Locations. 58.60-5 Section 58.60-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU...

  12. 46 CFR 58.60-5 - Industrial systems: Locations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Industrial systems: Locations. 58.60-5 Section 58.60-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU...

  13. 46 CFR 58.60-5 - Industrial systems: Locations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Industrial systems: Locations. 58.60-5 Section 58.60-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU...

  14. 46 CFR 58.60-5 - Industrial systems: Locations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Industrial systems: Locations. 58.60-5 Section 58.60-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU...

  15. Tuning HDF5 for Lustre File Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howison, Mark; Koziol, Quincey; Knaak, David

    2010-09-24

    HDF5 is a cross-platform parallel I/O library that is used by a wide variety of HPC applications for the flexibility of its hierarchical object-database representation of scientific data. We describe our recent work to optimize the performance of the HDF5 and MPI-IO libraries for the Lustre parallel file system. We selected three different HPC applications to represent the diverse range of I/O requirements, and measured their performance on three different systems to demonstrate the robustness of our optimizations across different file system configurations and to validate our optimization strategy. We demonstrate that the combined optimizations improve HDF5 parallel I/O performancemore » by up to 33 times in some cases running close to the achievable peak performance of the underlying file system and demonstrate scalable performance up to 40,960-way concurrency.« less

  16. The Space Technology 5 Power System Design

    NASA Technical Reports Server (NTRS)

    Stewart, Karen D.; Hernandez-Pellerano, Amri I.

    2005-01-01

    The Space Technology 5 (ST5) mission is a NASA New Millennium Program (NMP) project that was developed to validate new technologies for future missions and to demonstrate the feasibility of building and launching multiple, miniature spacecraft that can operate as science probes, collecting research quality measurements. The three satellites in the ST5 constellation will be launched into a sun synchronous LEO (Low Earth Orbit) in early 2006. ST5 fits in the 25 kilogram and 24 Watt class of miniature but fully capable spacecraft. The power system design features the use of new technology components and a low voltage power bus. In order to hold the mass and volume low and to qualify new technologies for future use in space, high efficiency triple junction solar cells and a lithium ion battery were baselined into the design. The Power System Electronics (PSE) was designed for a high radiation environment and uses hybrid microcircuits for power switching and over current protection. The ST5 power system architecture and technologies will be presented.

  17. Bacterial colonization of the implant-abutment interface of conical connection with an internal octagon: an in vitro study using real-time PCR.

    PubMed

    Baj, A; Beltramini, G A; Bolzoni, A; Cura, F; Palmieri, A; Scarano, A; Ottria, L; Giannì, A B

    2017-01-01

    Bacterial leakage at the implant-abutment connection of a two-piece implant system is considered the main cause of peri-implantitis. Prevention of bacterial leakage at the implant-abutment connection is mandatory for reducing inflammation process around implant neck and achieving bone stability. Micro-cavities at implant-abutment connection level can favour bacterial leakage, even in modern two-piece implant systems. The conical connection with an internal octagon (CCIO) is considered to be more stable mechanically and allows a more tight link between implant and abutment. As P. gingivalis and T. forsythia penetration might have clinical relevance, it was the purpose of this investigation to evaluate molecular leakage of these two bacteria in a new two-implant system with an internal conical implant-abutment connection with internal octagon (Shiner XT, FMD Falappa Medical Devices S.p.A. Rome, Italy). To verify the ability of the implant in protecting the internal space from the external environment, the passage of genetically modified Escherichia c oli across implant-abutment interface was evaluated. Four Shiner XT implants (FMD, Falappa Medical Devices®, Rome, Italy) were immerged in a bacterial culture for 24 h and bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 6% for P. gingivalis and 5% for T. forsythia. Other comparable studies about the tightness of the tested implant system reported similar results. The gap size at the implant-abutment connection of CCIOs was measured by other authors discovering a gap size of 1–2μm of the AstraTech system and of 4μm for the Ankylos system. Bacterial leakage along implant-abutment connection of cylindrical and tapered implants, Shiner XT, (FMD Falappa Medical Devices S.p.A. Rome, Italy) showed better results compared to other implants. Additional studies are needed to explore the relationship in terms of

  18. Ariane 5-ALF: Evolution of the Ariane 5 Data Handling System

    NASA Astrophysics Data System (ADS)

    Notebaert, O.; Stransky, Arnaud; Corin, Hans; Hult, Torbjorn; Bonnerot, Georges-Albert

    2004-06-01

    In the coming years, the Ariane 5 On-Board-Computer (OBC) will handle missions and performances enhancements together with the need for significantly reducing costs and the replacement of obsolescent components. The OBC evolution is naturally driven by these factors, but also needs to consider the SW system compliance. Indeed, it would be a major concern that the necessary change of the underlying HW should imply new development of the flight software, mission database and ground control system.The Ariane 5 SW uses ADA language, which enables verifiable definition of the interfaces and provides a standardized level of the real-time behavior. To enforce portability, it has a layered architecture that clearly separates application SW and data from the lower level software. In addition, the on-board mission data is managed thanks to the extraction of an image of the systems database located in a structured memory area (the exchange memory). Used for all interchanges between the system application software and the launcher's subsystems and peripherals, the exchange memory is the virtual view of the Ariane 5 system from the flight SW standpoint. Thanks to these early architectural and structural choices, portability on future hardware is theoretically guaranteed, whenever the exchange memory data structures and the service layer interfaces remains stable. The ALF working group has defined and manufactured a mock-up that fulfils these architectural constraints with a completely new on-board computer featuring improvements such as the microprocessor replacement as well as an advanced integrated I/O controller for access to the system data bus. Lower level SW has been prototyped on this new hardware in order to fulfill the same level of services as the current one while completely hiding the underlying HW/SW implementation to the rest of the system. Functional and performance evaluation of this platform consolidated at system level will show the potential benefits and the

  19. Comparative evaluation of microleakage of lingual retainer wires bonded with three different lingual retainer composites: an in vitro study.

    PubMed

    Nimbalkar-Patil, Smita; Vaz, Anna; Patil, Pravinkumar G

    2014-11-01

    To evaluate microleakage when two types of retainer wires were bonded with two light cured and a self cured lingual retainer composites. Total 120 freshly extracted human mandibular incisor teeth were collected and separated into six subgroups of 20 teeth each. Two different wires, a 0.036 inch hard round stainless steel (HRSS) wire sandblasted at the ends and 0.0175 inch multistranded wire bonded onto the lingual surfaces of the incisors with three different types of composite resins of 3M company; Concise Orthodontic (self-cure), Transbond XT (light-cure) and Transbond LR (light-cure). Specimens were further sealed with a nail varnish, stained with 0.5% basic fuchsine for 24 hours, sectioned and examined under a stereomicroscope, and scored for microleakage for the enamel-composite and wire-composite interfaces. Statistical analysis was performed by Kruskal-Wallis and Mann-Whitney U-tests. For HRSS wire, at the enamel-composite interface, the microleakage was least with Transbond LR followed by Concise Orthodontic and greatest for Transbond XT (p<0.05). At the wire composite interface too, the microleakage was in order of Transbond LRXT. For the multistranded wire, at the enamel-composite interface, the microleakage was least with Transbond LR followed by Concise Orthodontic and Transbond XT (p<0.05). At the wire composite interface too, it was seen that microleakage was the least with Transbond LR followed by Concise Orthodontic and Transbond XT. Transbond LR in combination with 0.0175 inch multistranded wire showed least microleakage amongst the groups studied.

  20. NAVO MSRC Navigator. Fall 2008

    DTIC Science & Technology

    2008-01-01

    arrival of our two new HPC systems, DAVINCI (IBM P6) and EINSTEIN (Cray XT5), and our new mass storage server, NEWTON (Sun M5000). “The most...will run on both DAVINCI and EINSTEIN, providing researchers with the capability of running jobs of up to 4,256 and 12,736 cores in size...are expected to double as EINSTEIN and DAVINCI are brought online. We have also strengthened the backbone of our Disaster Recovery infrastructure, as

  1. 14 CFR 60.5 - Quality management system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Quality management system. 60.5 Section 60.5 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND CONTINUING QUALIFICATION AND USE § 60.5 Quality...

  2. 14 CFR 60.5 - Quality management system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Quality management system. 60.5 Section 60.5 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND CONTINUING QUALIFICATION AND USE § 60.5 Quality...

  3. 14 CFR 60.5 - Quality management system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Quality management system. 60.5 Section 60.5 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND CONTINUING QUALIFICATION AND USE § 60.5 Quality...

  4. 14 CFR 60.5 - Quality management system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Quality management system. 60.5 Section 60.5 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND CONTINUING QUALIFICATION AND USE § 60.5 Quality...

  5. Adaptive Antenna System for Both 4G LTE and 5G Cellular Systems

    NASA Astrophysics Data System (ADS)

    Henderson, Kendrick Q. T.

    Given the steep increase in the use of mobile communication systems, the current 4G/LTE (Long Term Evolution), cellular system will not be able to handle the increase in data. It is estimated that by 2020 the bandwidth requirements will be 10 times greater than what LTE can sustain. A new 5th generation (5G) communication system has been proposed to meet this demand. The physical layer or the antenna is the most critical part of any wireless communication systems as it is the interface between the free space medium and an electrical circuit. It sets the margin for almost all design parameters in the system such as the system noise and bandwidth. Several interactions of antennas have been proposed over the years for cellular services. These antennas are of various geometries, bandwidths, and radiation patterns with almost all having linear polarization. This thesis attempts to solve the multiple LTE antenna problem by creating a simple antenna that covers most of the LTE bands (850-2700 MHz) as well as introducing an antenna system at the 28 GHz 5G band. This allows for a greater educated hypothesis into what 5G can offer at the physical layer. The proposed concept will provide a solution to the co-existence problem of upcoming 5G wireless systems to be interoperable with existing 4G/LTE system.

  6. Effect of different polishing systems on the surface roughness of nano-hybrid composites.

    PubMed

    Patel, Brijesh; Chhabra, Naveen; Jain, Disha

    2016-01-01

    The study aimed to investigate the influence of different polishing systems on the surface roughness of nano-hybrid composite resins. Different shapes of polishing systems are available according to the site of work. To minimize variability, a new system with single shape is developed that can be utilized in both anterior as well as posterior teeth. Seventy composite discs were fabricated using Teflon well (10 mm × 3 mm). Two main group of nano-hybrid composite Group I - Filtek Z350 and Group II - Tetric N-Ceram were used (n = 35 for each group). Both groups were further divided into four subgroups. Subgroup a - OneGloss (n = 10), Subgroup b - PoGo (n = 10), Subgroup c - Sof-Lex spiral (n = 10), Subgroup d - Mylar strip (control, n = 5). Samples were polished according to the manufacturer's recommendations. Surface roughness test was performed using contact profilometer. The obtained data were analyzed using the one-way analysis of variance test. Tetric N-Ceram produced smoother surfaces than Filtek Z350 (P < 0.05). Mylar strip and "PoGo" created equally smooth surfaces, while significantly rougher surfaces were obtained after applications of "Sof-Lex spiral" and "OneGloss" (P < 0.05). Polishing ability of Tetric N-Ceram is better than Filtek Z350 XT. "PoGo" seems to be a better polishing system than "OneGloss" and "Sof-Lex Spiral."

  7. 43 CFR 3101.5 - National Wildlife Refuge System lands.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false National Wildlife Refuge System lands. 3101.5 Section 3101.5 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF... Leases § 3101.5 National Wildlife Refuge System lands. ...

  8. 43 CFR 3101.5 - National Wildlife Refuge System lands.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false National Wildlife Refuge System lands. 3101.5 Section 3101.5 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF... Leases § 3101.5 National Wildlife Refuge System lands. ...

  9. 43 CFR 3101.5 - National Wildlife Refuge System lands.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false National Wildlife Refuge System lands. 3101.5 Section 3101.5 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF... Leases § 3101.5 National Wildlife Refuge System lands. ...

  10. 43 CFR 3101.5 - National Wildlife Refuge System lands.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false National Wildlife Refuge System lands. 3101.5 Section 3101.5 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF... Leases § 3101.5 National Wildlife Refuge System lands. ...

  11. Chromosome Banding in Amphibia. XXXVI. Multimorphic Sex Chromosomes and an Enigmatic Sex Determination in Eleutherodactylus johnstonei (Anura, Eleutherodactylidae).

    PubMed

    Schmid, Michael; Steinlein, Claus

    2018-01-01

    A detailed cytogenetic study on the leaf litter frog Eleutherodactylus johnstonei from 14 different Caribbean islands and the mainlands of Venezuela and Guyana revealed the existence of multimorphic XY♂/XX♀ sex chromosomes 14. Their male sex determination and development depends either on the presence of 2 telocentric chromosomes 14 (XtYt), or on 1 submetacentric chromosome 14 (Xsm) plus 1 telocentric chromosome 14 (Yt), or on the presence of 2 submetacentric chromosomes 14 (XsmYsm). The female sex determination and development requires either the presence of 2 telocentric chromosomes 14 (XtXt) or 2 submetacentric chromosomes 14 (XsmXsm). In all individuals analyzed, the sex chromosomes 14 carry a prominent nucleolus organizer region in their long arms. An explanation is given for the origin of the (XtYt)♂, (XsmYt)♂, (XsmYsm)♂, (XtXt)♀, and (XsmXsm)♀ in the different populations of E. johnstonei. Furthermore, the present study gives detailed data on the chromosome banding patterns, in situ hybridization experiments, and the genome size of E. johnstonei. © 2018 S. Karger AG, Basel.

  12. The Space Technology 5 Avionics System

    NASA Technical Reports Server (NTRS)

    Speer, Dave; Jackson, George; Stewart, Karen; Hernandez-Pellerano, Amri

    2004-01-01

    The Space Technology 5 (ST5) mission is a NASA New Millennium Program project that will validate new technologies for future space science missions and demonstrate the feasibility of building launching and operating multiple, miniature spacecraft that can collect research-quality in-situ science measurements. The three satellites in the ST5 constellation will be launched into a sun-synchronous Earth orbit in early 2006. ST5 fits into the 25-kilogram and 24-watt class of very small but fully capable spacecraft. The new technologies and design concepts for a compact power and command and data handling (C&DH) avionics system are presented. The 2-card ST5 avionics design incorporates new technology components while being tightly constrained in mass, power and volume. In order to hold down the mass and volume, and quali& new technologies for fUture use in space, high efficiency triple-junction solar cells and a lithium-ion battery were baselined into the power system design. The flight computer is co-located with the power system electronics in an integral spacecraft structural enclosure called the card cage assembly. The flight computer has a full set of uplink, downlink and solid-state recording capabilities, and it implements a new CMOS Ultra-Low Power Radiation Tolerant logic technology. There were a number of challenges imposed by the ST5 mission. Specifically, designing a micro-sat class spacecraft demanded that minimizing mass, volume and power dissipation would drive the overall design. The result is a very streamlined approach, while striving to maintain a high level of capability, The mission's radiation requirements, along with the low voltage DC power distribution, limited the selection of analog parts that can operate within these constraints. The challenge of qualifying new technology components for the space environment within a short development schedule was another hurdle. The mission requirements also demanded magnetic cleanliness in order to reduce

  13. Effects of Different Combinations of Er:YAG Laser-Adhesives on Enamel Demineralization and Bracket Bond Strength

    PubMed Central

    Nalçacı, Ruhi; Üşümez, Serdar; Malkoç, Sıddık

    2016-01-01

    Abstract Objective: The purpose of this study was to investigate the demineralization around brackets and shear bond strength (SBS) of brackets bonded to Er:YAG laser-irradiated enamel at different power settings with various adhesive systems combinations. Methods: A total of 108 premolar teeth were used in this study. Teeth were assigned into three groups according to the etching procedure, then each group divided into three subgroups based on the application of different adhesive systems. There were a total of nine groups as follows. Group 1: Acid + Transbond XT Primer; group 2: Er:YAG (100 mJ, 10 Hz) etching + Transbond XT Primer; group 3: Er:YAG (200 mJ, 10 Hz) etching + Transbond XT Primer; group 4: Transbond Plus self-etching primer (SEP); group 5: Er:YAG (100 mJ, 10 Hz) etching + Transbond Plus SEP; group 6: Er:YAG (200 mJ, 10 Hz) etching + Transbond Plus SEP; group 7: Clearfil Protect Bond; group 8: Er:YAG (100 mJ, 10 Hz) etching + Clearfil Protect Bond; group 9: Er:YAG (200 mJ, 10 Hz) etching + Clearfil Protect Bond. Brackets were bonded with Transbond XT Adhesive Paste in all groups. Teeth to be evaluated for demineralization and SBS were exposed to pH and thermal cyclings, respectively. Then, demineralization samples were scanned with micro-CT to determine lesion depth values. For SBS test, a universal testing machine was used and adhesive remnant was index scored after debonding. Data were analyzed statistically. Results: No significant differences were found among the lesion depth values of the various groups, except for G7 and G8, in which the lowest values were recorded. The lowest SBS values were in G7, whereas the highest were in G9. The differences between the other groups were not significant. Conclusions: Er:YAG laser did not have a positive effect on prevention of enamel demineralization. When two step self-etch adhesive is preferred for bonding brackets, laser etching at 1 W (100 mJ, 10 Hz) is

  14. The NATO III 5 MHz Distribution System

    NASA Technical Reports Server (NTRS)

    Vulcan, A.; Bloch, M.

    1981-01-01

    A high performance 5 MHz distribution system is described which has extremely low phase noise and jitter characteristics and provides multiple buffered outputs. The system is completely redundant with automatic switchover and is self-testing. Since the 5 MHz reference signals distributed by the NATO III distribution system are used for up-conversion and multiplicative functions, a high degree of phase stability and isolation between outputs is necessary. Unique circuit design and packaging concepts insure that the isolation between outputs is sufficient to quarantee a phase perturbation of less than 0.0016 deg when other outputs are open circuited, short circuited or terminated in 50 ohms. Circuit design techniques include high isolation cascode amplifiers. Negative feedback stabilizes system gain and minimizes circuit phase noise contributions. Balanced lines, in lieu of single ended coaxial transmission media, minimize pickup.

  15. Linux Kernel Co-Scheduling For Bulk Synchronous Parallel Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Terry R

    2011-01-01

    This paper describes a kernel scheduling algorithm that is based on co-scheduling principles and that is intended for parallel applications running on 1000 cores or more where inter-node scalability is key. Experimental results for a Linux implementation on a Cray XT5 machine are presented.1 The results indicate that Linux is a suitable operating system for this new scheduling scheme, and that this design provides a dramatic improvement in scaling performance for synchronizing collective operations at scale.

  16. : A Scalable and Transparent System for Simulating MPI Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perumalla, Kalyan S

    2010-01-01

    is a scalable, transparent system for experimenting with the execution of parallel programs on simulated computing platforms. The level of simulated detail can be varied for application behavior as well as for machine characteristics. Unique features of are repeatability of execution, scalability to millions of simulated (virtual) MPI ranks, scalability to hundreds of thousands of host (real) MPI ranks, portability of the system to a variety of host supercomputing platforms, and the ability to experiment with scientific applications whose source-code is available. The set of source-code interfaces supported by is being expanded to support a wider set of applications, andmore » MPI-based scientific computing benchmarks are being ported. In proof-of-concept experiments, has been successfully exercised to spawn and sustain very large-scale executions of an MPI test program given in source code form. Low slowdowns are observed, due to its use of purely discrete event style of execution, and due to the scalability and efficiency of the underlying parallel discrete event simulation engine, sik. In the largest runs, has been executed on up to 216,000 cores of a Cray XT5 supercomputer, successfully simulating over 27 million virtual MPI ranks, each virtual rank containing its own thread context, and all ranks fully synchronized by virtual time.« less

  17. 5 CFR 9701.405 - Performance management system requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... performance management systems for DHS employees, subject to the requirements set forth in this subpart. (b) Each DHS performance management system must— (1) Specify the employees covered by the system(s); (2... 5 Administrative Personnel 3 2013-01-01 2013-01-01 false Performance management system...

  18. 5 CFR 9701.405 - Performance management system requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... performance management systems for DHS employees, subject to the requirements set forth in this subpart. (b) Each DHS performance management system must— (1) Specify the employees covered by the system(s); (2... 5 Administrative Personnel 3 2011-01-01 2011-01-01 false Performance management system...

  19. 5 CFR 9701.405 - Performance management system requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... performance management systems for DHS employees, subject to the requirements set forth in this subpart. (b) Each DHS performance management system must— (1) Specify the employees covered by the system(s); (2... 5 Administrative Personnel 3 2012-01-01 2012-01-01 false Performance management system...

  20. 5 CFR 9701.405 - Performance management system requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... performance management systems for DHS employees, subject to the requirements set forth in this subpart. (b) Each DHS performance management system must— (1) Specify the employees covered by the system(s); (2... 5 Administrative Personnel 3 2014-01-01 2014-01-01 false Performance management system...

  1. Simultaneous detection of 5-fluorocytosine and 5-fluorouracil in human cells carrying CD/5-FC suicide gene system by using capillary zone electrophoresis.

    PubMed

    Liu, Yajing; Zhu, Pan; Huang, Zhiwei; Zhou, Li; Shi, Ping

    2018-02-15

    A well-known suicide gene therapy approach, cytosine deaminase (CD) in combination with prodrug 5-flurocytosine (5-FC), has become an effective strategy of tumor treatment. However, there are short of simple and convenient detection methods to evaluate the efficiency of 5-FC conversion to 5-fluorouracil (5-FU) in human cells carrying various CD/5-FC systems. In this study, we developed an effective capillary zone electrophoresis (CZE) method to simultaneously measure 5-FC and 5-FU in cells carrying CD/5-FC suicide gene system. Under the condition of 60 mM borate buffer (pH 9.5) and 25 kV separation voltage with 0.5 psi × 15 s injection in 210 nm, the separation of 5-FC and 5-FU could be completely achieved within 15 min. The linearity of the calibration curve of standard 5-FC and 5-FU was in the range from 1 to 1000 μM (r 2  > 0.999) and their recoveries were 98.4% and 96.0%, respectively. Due to the simple sample preparation and easy detection, this method is suitable for the study of the conversion efficiency of CD/5-FC suicide gene system. It aims to intuitively evaluate CD/5-FC systems and helps to guide the improvement of more effective CD/5-FC suicide gene systems. Copyright © 2018. Published by Elsevier B.V.

  2. 6 CFR 5.31 - Security of systems of records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Security of systems of records. 5.31 Section 5.31 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY DISCLOSURE OF RECORDS AND INFORMATION Privacy Act § 5.31 Security of systems of records. (a) In general. Each component...

  3. 46 CFR 62.35-5 - Remote propulsion-control systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Remote propulsion-control systems. 62.35-5 Section 62.35... AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-5 Remote propulsion-control systems. (a) Manual propulsion control. All vessels having remote propulsion control from the navigating...

  4. 46 CFR 62.35-5 - Remote propulsion-control systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Remote propulsion-control systems. 62.35-5 Section 62.35... AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-5 Remote propulsion-control systems. (a) Manual propulsion control. All vessels having remote propulsion control from the navigating...

  5. 46 CFR 62.35-5 - Remote propulsion-control systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Remote propulsion-control systems. 62.35-5 Section 62.35... AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-5 Remote propulsion-control systems. (a) Manual propulsion control. All vessels having remote propulsion control from the navigating...

  6. 46 CFR 62.35-5 - Remote propulsion-control systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Remote propulsion-control systems. 62.35-5 Section 62.35... AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-5 Remote propulsion-control systems. (a) Manual propulsion control. All vessels having remote propulsion control from the navigating...

  7. 46 CFR 62.35-5 - Remote propulsion-control systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Remote propulsion-control systems. 62.35-5 Section 62.35... AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-5 Remote propulsion-control systems. (a) Manual propulsion control. All vessels having remote propulsion control from the navigating...

  8. 5 CFR 430.304 - SES performance management systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false SES performance management systems. 430... PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.304 SES performance management systems. (a... or more performance management systems for its senior executives. (b) Performance management systems...

  9. 5 CFR 430.304 - SES performance management systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false SES performance management systems. 430... PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.304 SES performance management systems. (a... or more performance management systems for its senior executives. (b) Performance management systems...

  10. 5 CFR 430.304 - SES performance management systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false SES performance management systems. 430... PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.304 SES performance management systems. (a... or more performance management systems for its senior executives. (b) Performance management systems...

  11. 5 CFR 430.304 - SES performance management systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false SES performance management systems. 430... PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.304 SES performance management systems. (a... or more performance management systems for its senior executives. (b) Performance management systems...

  12. B =5 Skyrmion as a two-cluster system

    NASA Astrophysics Data System (ADS)

    Gudnason, Sven Bjarke; Halcrow, Chris

    2018-06-01

    The classical B =5 Skyrmion can be approximated by a two-cluster system in which a B =1 Skyrmion is attached to a core B =4 Skyrmion. We quantize this system, allowing the B =1 to freely orbit the core. The configuration space is 11 dimensional but simplifies significantly after factoring out the overall spin and isospin degrees of freedom. We exactly solve the free quantum problem and then include an interaction potential between the Skyrmions numerically. The resulting energy spectrum is compared to the corresponding nuclei—the helium-5/lithium-5 isodoublet. We find approximate parity doubling not seen in the experimental data. In addition, we fail to obtain the correct ground-state spin. The framework laid out for this two-cluster system can readily be modified for other clusters and in particular for other B =4 n +1 nuclei, of which B =5 is the simplest example.

  13. Using IMSL Mathematical and Statistical Computer Subroutines in Physiological and Biomechanical Research

    DTIC Science & Technology

    1987-10-01

    NDATA). CSCOEF(4.NDATA). CSVAL. ERROR, F. kFDATA(NDATA). FLOAT, FVAL. RNUNF, SDEV. SMPAR. SQRT. a SYAL . WEIGHT(NDATA), X. XDATA(NDATA). XT INTRINSIC...BREAK.CSCOEF) FYAL - F(XT) ERROR a SVAL - FVAL WRITE (NOUT,’(4F15.4)’) XT. FYAL. SYAL , ERROR 30 CONTINUE C 99999 FORMAT (12X. ’X’. 9X. ’Function’. 7X

  14. Biocompatibility of orthodontic adhesives in rat subcutaneous tissue

    PubMed Central

    dos SANTOS, Rogério Lacerda; PITHON, Matheus Melo; FERNANDES, Alline Birra Nolasco; CABRAL, Márcia Grillo; RUELLAS, Antônio Carlos de Oliveira

    2010-01-01

    Objective The objective of the present study was to verify the hypothesis that no difference in biocompatibility exists between different orthodontic adhesives. Material and Methods Thirty male Wistar rats were used in this study and divided into five groups (n=6): Group 1 (control, distilled water), Group 2 (Concise), Group 3 (Xeno III), Group 4 (Transbond XT), and Group 5 (Transbond plus Self-Etching Primer). Two cavities were performed in the subcutaneous dorsum of each animal to place a polyvinyl sponge soaked with 2 drops of the respective adhesive in each surgical loci. Two animals of each group were sacrificed after 7, 15, and 30 days, and their tissues were analyzed by using an optical microscope. Results At day 7, Groups 3 (Transbond XT) and 4 (Xeno III) showed intense mono- and polymorphonuclear inflammatory infiltrate with no differences between them, whereas Groups 1 (control) and 2 (Concise) showed moderate mononuclear inflammatory infiltrate. At day 15, severe inflammation was observed in Group 3 (Transbond XT) compared to other groups. At day 30, the same group showed a more expressive mononuclear inflammatory infiltrate compared to other groups. Conclusion Among the orthodontic adhesive analyzed, it may be concluded that Transbond XT exhibited the worst biocompatibility. However, one cannot interpret the specificity of the data generated in vivo animal models as a human response. PMID:21085807

  15. Genetic Analysis of Hedgehog Signaling in Ventral Body Wall Development and the Onset of Omphalocele Formation

    PubMed Central

    Matsumaru, Daisuke; Haraguchi, Ryuma; Miyagawa, Shinichi; Motoyama, Jun; Nakagata, Naomi; Meijlink, Frits; Yamada, Gen

    2011-01-01

    Background An omphalocele is one of the major ventral body wall malformations and is characterized by abnormally herniated viscera from the body trunk. It has been frequently found to be associated with other structural malformations, such as genitourinary malformations and digit abnormalities. In spite of its clinical importance, the etiology of omphalocele formation is still controversial. Hedgehog (Hh) signaling is one of the essential growth factor signaling pathways involved in the formation of the limbs and urogenital system. However, the relationship between Hh signaling and ventral body wall formation remains unclear. Methodology/Principal Findings To gain insight into the roles of Hh signaling in ventral body wall formation and its malformation, we analyzed phenotypes of mouse mutants of Sonic hedgehog (Shh), GLI-Kruppel family member 3 (Gli3) and Aristaless-like homeobox 4 (Alx4). Introduction of additional Alx4Lst mutations into the Gli3Xt/Xt background resulted in various degrees of severe omphalocele and pubic diastasis. In addition, loss of a single Shh allele restored the omphalocele and pubic symphysis of Gli3Xt/+; Alx4Lst/Lst embryos. We also observed ectopic Hh activity in the ventral body wall region of Gli3Xt/Xt embryos. Moreover, tamoxifen-inducible gain-of-function experiments to induce ectopic Hh signaling revealed Hh signal dose-dependent formation of omphaloceles. Conclusions/Significance We suggest that one of the possible causes of omphalocele and pubic diastasis is ectopically-induced Hh signaling. To our knowledge, this would be the first demonstration of the involvement of Hh signaling in ventral body wall malformation and the genetic rescue of omphalocele phenotypes. PMID:21283718

  16. 48 CFR 209.571-5 - Lead system integrators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Lead system integrators... Consultant Conflicts of Interest 209.571-5 Lead system integrators. For limitations on contractors acting as lead systems integrators, see 209.570. [75 FR 81913, Dec. 29, 2010] ...

  17. 48 CFR 209.571-5 - Lead system integrators.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Lead system integrators... Consultant Conflicts of Interest 209.571-5 Lead system integrators. For limitations on contractors acting as lead systems integrators, see 209.570. [75 FR 81913, Dec. 29, 2010] ...

  18. 48 CFR 209.571-5 - Lead system integrators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Lead system integrators... Consultant Conflicts of Interest 209.571-5 Lead system integrators. For limitations on contractors acting as lead systems integrators, see 209.570. [75 FR 81913, Dec. 29, 2010] ...

  19. 48 CFR 209.571-5 - Lead system integrators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Lead system integrators... Consultant Conflicts of Interest 209.571-5 Lead system integrators. For limitations on contractors acting as lead systems integrators, see 209.570. [75 FR 81913, Dec. 29, 2010] ...

  20. Large-Scale Low-Cost NGS Library Preparation Using a Robust Tn5 Purification and Tagmentation Protocol

    PubMed Central

    Hennig, Bianca P.; Velten, Lars; Racke, Ines; Tu, Chelsea Szu; Thoms, Matthias; Rybin, Vladimir; Besir, Hüseyin; Remans, Kim; Steinmetz, Lars M.

    2017-01-01

    Efficient preparation of high-quality sequencing libraries that well represent the biological sample is a key step for using next-generation sequencing in research. Tn5 enables fast, robust, and highly efficient processing of limited input material while scaling to the parallel processing of hundreds of samples. Here, we present a robust Tn5 transposase purification strategy based on an N-terminal His6-Sumo3 tag. We demonstrate that libraries prepared with our in-house Tn5 are of the same quality as those processed with a commercially available kit (Nextera XT), while they dramatically reduce the cost of large-scale experiments. We introduce improved purification strategies for two versions of the Tn5 enzyme. The first version carries the previously reported point mutations E54K and L372P, and stably produces libraries of constant fragment size distribution, even if the Tn5-to-input molecule ratio varies. The second Tn5 construct carries an additional point mutation (R27S) in the DNA-binding domain. This construct allows for adjustment of the fragment size distribution based on enzyme concentration during tagmentation, a feature that opens new opportunities for use of Tn5 in customized experimental designs. We demonstrate the versatility of our Tn5 enzymes in different experimental settings, including a novel single-cell polyadenylation site mapping protocol as well as ultralow input DNA sequencing. PMID:29118030

  1. Effect of Instrument Lubricants on the Surface Degree of Conversion and Crosslinking Density of Nanocomposites.

    PubMed

    de Paula, Felipe Costa; Valentin, Regis de Souza; Borges, Boniek Castillo Dutra; Medeiros, Maria Cristina Dos Santos; de Oliveira, Raiza Freitas; da Silva, Ademir Oliveira

    2016-01-01

    The surface degree of conversion and crosslink density of composites should not be affected by the use of instrument lubricants in order to provide long-lasting tooth restorations. This study aimed to analyze the effect of instrument lubricants on the degree of conversion and crosslink density of nanocomposites. Samples (N = 10) were fabricated according to the composites (Filtek Z350 XT, 3M ESPE, St. Paul, MN, USA; and IPS Empress Direct, Ivoclar Vivadent AG, Schaan, Liechtenstein and lubricants used (Adper Single Bond 2 and Scotchbond Multi-Purpose bonding agent adhesive systems, 3M ESPE; 70% ethanol, absolute ethanol, and no lubricant). Single composite increments were inserted into a Teflon mold using the same dental instrument. The composite surface was then modeled using a brush wiped with each adhesive system and a spatula wiped with each ethanol. The control group was fabricated with no additional modeling. The surface degree of conversion and crosslink density were measured by Fourier transform infrared spectroscopy and the hardness decrease test, respectively. Data were analyzed using two-way analysis of variance and the Tukey's test (p < 0.05). Filtek Z350 XT showed statistically similar degree of conversion regardless of the lubricant used, whereas the use of adhesive systems and 70% ethanol decreased the degree of conversion for IPS Empress Direct. Only Scotchbond Multi-Purpose bonding agent decreased crosslink density for Filtek Z350 XT, whereas both adhesive systems decreased crosslink density for IPS Empress Direct. Filtek Z350 XT appeared to be less sensitive to the effects of lubricants, and absolute ethanol did not affect the degree of conversion and crosslink density of the nanocomposites tested. Although the use of lubricants may be recommended to minimize the stickiness of dental instruments and composite resin, dentists should choose materials that do not have a negative effect on the surface properties of composites. Only the use of

  2. 21 CFR 862.1390 - 5-Hydroxyindole acetic acid/serotonin test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false 5-Hydroxyindole acetic acid/serotonin test system... Test Systems § 862.1390 5-Hydroxyindole acetic acid/serotonin test system. (a) Identification. A 5-hydroxyindole acetic acid/serotonin test system is a device intended to measure 5-hydroxyindole acetic acid...

  3. 21 CFR 862.1390 - 5-Hydroxyindole acetic acid/serotonin test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false 5-Hydroxyindole acetic acid/serotonin test system... Test Systems § 862.1390 5-Hydroxyindole acetic acid/serotonin test system. (a) Identification. A 5-hydroxyindole acetic acid/serotonin test system is a device intended to measure 5-hydroxyindole acetic acid...

  4. 21 CFR 862.1390 - 5-Hydroxyindole acetic acid/serotonin test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false 5-Hydroxyindole acetic acid/serotonin test system... Test Systems § 862.1390 5-Hydroxyindole acetic acid/serotonin test system. (a) Identification. A 5-hydroxyindole acetic acid/serotonin test system is a device intended to measure 5-hydroxyindole acetic acid...

  5. 21 CFR 862.1390 - 5-Hydroxyindole acetic acid/serotonin test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false 5-Hydroxyindole acetic acid/serotonin test system... Test Systems § 862.1390 5-Hydroxyindole acetic acid/serotonin test system. (a) Identification. A 5-hydroxyindole acetic acid/serotonin test system is a device intended to measure 5-hydroxyindole acetic acid...

  6. SITE TECHNOLOGY CAPSULE: INPLANT SYSTEMS, INC. SFC 0.5 OLEOFILTRATION SYSTEM

    EPA Science Inventory

    Oleofiltration is used to separate suspended, emulsified and a portion of dissolved hydrocarbons from water. The InPlant Systems, Inc., SFC 0.5 Oleofiltration System was demonstrated under the SITE Program in June 1994 at a Superfund site in Florida that was contaminated with 29,...

  7. 5 CFR 843.210 - Transfers between retirement systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 2 2013-01-01 2013-01-01 false Transfers between retirement systems. 843... REGULATIONS (CONTINUED) FEDERAL EMPLOYEES RETIREMENT SYSTEM-DEATH BENEFITS AND EMPLOYEE REFUNDS One-time Payments § 843.210 Transfers between retirement systems. Transfers of employees' contributions between the...

  8. 5 CFR 843.210 - Transfers between retirement systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Transfers between retirement systems. 843... REGULATIONS (CONTINUED) FEDERAL EMPLOYEES RETIREMENT SYSTEM-DEATH BENEFITS AND EMPLOYEE REFUNDS One-time Payments § 843.210 Transfers between retirement systems. Transfers of employees' contributions between the...

  9. 5 CFR 843.210 - Transfers between retirement systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 2 2014-01-01 2014-01-01 false Transfers between retirement systems. 843... REGULATIONS (CONTINUED) FEDERAL EMPLOYEES RETIREMENT SYSTEM-DEATH BENEFITS AND EMPLOYEE REFUNDS One-time Payments § 843.210 Transfers between retirement systems. Transfers of employees' contributions between the...

  10. 5 CFR 843.210 - Transfers between retirement systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 2 2012-01-01 2012-01-01 false Transfers between retirement systems. 843... REGULATIONS (CONTINUED) FEDERAL EMPLOYEES RETIREMENT SYSTEM-DEATH BENEFITS AND EMPLOYEE REFUNDS One-time Payments § 843.210 Transfers between retirement systems. Transfers of employees' contributions between the...

  11. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  12. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  13. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  14. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  15. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  16. Pre-treating dentin with chlorhexadine and CPP-ACP: self-etching and universal adhesive systems

    PubMed Central

    dos Santos, Ricardo Alves; de Lima, Eliane Alves; Montes, Marcos Antônio Japiassu Resende; Braz, Rodivan

    2016-01-01

    Abstract Objective: The aim of the present study was to compare the effect of pre-treating dentin with chlorhexidine, at concentrations of 0.2% and 2%, and remineralizing paste containing CPP-ACP (MI Paste – GC) on the bond strength of adhesive systems. Material and methods: In total, 80 slides of dentin were used. These slides were 2 mm thick and were obtained from bovine incisors. Standard cavities were created using diamond bur number 3131. In the control groups, a Scotchbond Universal Adhesive (SUA) self-etching adhesive system of 3M ESPE and a Clearfil SE Bond (CSE) adhesive system of Kuraray were applied, following the manufacturer’s instructions. In the other groups, dentin was pretreated with chlorhexidine (0.2% and 2%) for 1 min and with MI Paste for 3 min. The cavities were restored with Z350 XT resin (3M ESPE). After 24 h of storage, the push-out test was applied at a speed of 0.5 mm/min. Results: The different dentin pretreatment techniques did not affect the intra-adhesive bond strength. There was a difference between treatment with MI Paste and chlorhexidine 0.2% in favor of the SUA, with values of 15.22 and 20.25 Mpa, respectively. Conclusions: The different pretreatment methods did not alter the immediate bond strength to dentin. Differences were only recorded when comparing the adhesives. PMID:28642915

  17. Pre-treating dentin with chlorhexadine and CPP-ACP: self-etching and universal adhesive systems.

    PubMed

    Dos Santos, Ricardo Alves; de Lima, Eliane Alves; Montes, Marcos Antônio Japiassu Resende; Braz, Rodivan

    2016-12-01

    Objective: The aim of the present study was to compare the effect of pre-treating dentin with chlorhexidine, at concentrations of 0.2% and 2%, and remineralizing paste containing CPP-ACP (MI Paste - GC) on the bond strength of adhesive systems. Material and methods: In total, 80 slides of dentin were used. These slides were 2 mm thick and were obtained from bovine incisors. Standard cavities were created using diamond bur number 3131. In the control groups, a Scotchbond Universal Adhesive (SUA) self-etching adhesive system of 3M ESPE and a Clearfil SE Bond (CSE) adhesive system of Kuraray were applied, following the manufacturer's instructions. In the other groups, dentin was pretreated with chlorhexidine (0.2% and 2%) for 1 min and with MI Paste for 3 min. The cavities were restored with Z350 XT resin (3M ESPE). After 24 h of storage, the push-out test was applied at a speed of 0.5 mm/min. Results: The different dentin pretreatment techniques did not affect the intra-adhesive bond strength. There was a difference between treatment with MI Paste and chlorhexidine 0.2% in favor of the SUA, with values of 15.22 and 20.25 Mpa, respectively. Conclusions: The different pretreatment methods did not alter the immediate bond strength to dentin. Differences were only recorded when comparing the adhesives.

  18. 32 CFR 327.5 - Systems of records.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 2 2014-07-01 2014-07-01 false Systems of records. 327.5 Section 327.5 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY OF DEFENSE (CONTINUED) PRIVACY PROGRAM... disclosure within the Department of Defense (DoD). The contractor is considered the agent of DeCA and is to...

  19. Optic Nerve Sheath Tethering in Adduction Occurs in Esotropia and Hypertropia, But Not in Exotropia

    PubMed Central

    Suh, Soh Youn; Clark, Robert A.; Demer, Joseph L.

    2018-01-01

    Purpose Repetitive strain to the optic nerve (ON) due to tethering in adduction has been recently proposed as an intraocular pressure-independent mechanism of optic neuropathy in primary open-angle glaucoma. Since strabismus may alter adduction, we investigated whether gaze-related ON straightening and associated globe translation differ in horizontal and vertical strabismus. Methods High-resolution orbital magnetic resonance imaging was obtained in 2-mm thick quasi-coronal planes using surface coils in 25 subjects (49 orbits) with esotropia (ET, 19 ± 3.6Δ SEM), 11 (15 orbits) with exotropia (XT, 33.7 ± 7.3Δ), 7 (12 orbits) with hypertropia (HT, 14.6 ± 3.2Δ), and 31 normal controls (62 orbits) in target-controlled central gaze, and in maximum attainable abduction and adduction. Area centroids were used to determine ON path sinuosity and globe positions. Results Adduction angles achieved in ET (30.6° ± 0.9°) and HT (27.2° ± 2.3°) did not significantly differ from normal (28.3° ± 0.7°), but significantly less adduction was achieved in XT (19.0° ± 2.5°, P = 0.005). ON sheath tethering in adduction occurred in ET and HT similarly to normal, but did not in XT. The globe translated significantly less than normal, nasally in adduction in XT and temporally in abduction in ET and HT (P < 0.02, for all). Globe retraction did not occur during abduction or adduction in any group. Conclusions Similar to normal subjects, the ON and sheath become tethered without globe retraction in ET and HT. In XT, adduction tethering does not occur, possibly due to limited adduction angle. Thus, therapeutic limitation of adduction could be considered as a possible treatment for ON sheath tethering.

  20. Effect of different polishing systems on the surface roughness of nano-hybrid composites

    PubMed Central

    Patel, Brijesh; Chhabra, Naveen; Jain, Disha

    2016-01-01

    Objective: The study aimed to investigate the influence of different polishing systems on the surface roughness of nano-hybrid composite resins. Background: Different shapes of polishing systems are available according to the site of work. To minimize variability, a new system with single shape is developed that can be utilized in both anterior as well as posterior teeth. Materials and Methods: Seventy composite discs were fabricated using Teflon well (10 mm × 3 mm). Two main group of nano-hybrid composite Group I — Filtek Z350 and Group II — Tetric N-Ceram were used (n = 35 for each group). Both groups were further divided into four subgroups. Subgroup a — OneGloss (n = 10), Subgroup b - PoGo (n = 10), Subgroup c — Sof-Lex spiral (n = 10), Subgroup d - Mylar strip (control, n = 5). Samples were polished according to the manufacturer's recommendations. Surface roughness test was performed using contact profilometer. The obtained data were analyzed using the one-way analysis of variance test. Result: Tetric N-Ceram produced smoother surfaces than Filtek Z350 (P < 0.05). Mylar strip and “PoGo” created equally smooth surfaces, while significantly rougher surfaces were obtained after applications of “Sof-Lex spiral” and “OneGloss” (P < 0.05). Conclusion: Polishing ability of Tetric N-Ceram is better than Filtek Z350 XT. “PoGo” seems to be a better polishing system than “OneGloss” and “Sof-Lex Spiral.” PMID:26957791

  1. Effect of the Polishing Procedures on Color Stability and Surface Roughness of Composite Resins

    PubMed Central

    Schmitt, Vera Lucia; Puppin-Rontani, Regina Maria; Naufel, Fabiana Scarparo; Nahsan, Flávia Pardo Salata; Alexandre Coelho Sinhoreti, Mário; Baseggio, Wagner

    2011-01-01

    Objectives. To evaluate the polishing procedures effect on color stability and surface roughness of composite resins. Methods. Specimens were distributed into 6 groups: G1: Filtek Supreme XT + PoGo; G2: Filtek Supreme XT + Sof-Lex; G3: Filtek Supreme XT + no polishing; G4: Amelogen + PoGo; G5: Amelogen + Sof-Lex.; G6: Amelogen + no polishing. Initial color values were evaluated using the CIELab scale. After polishing, surface roughness was evaluated and the specimens were stored in coffee solution at 37°C for 7 days. The final color measurement and roughness were determined. Results. Sof-Lex resulted in lower staining. Amelogen showed the highest roughness values than Filtek Supreme on baseline and final evaluations regardless of the polishing technique. Filtek Supreme polished with PoGo showed the lowest roughness values. All groups presented discoloration after storage in coffee solution, regardless of the polishing technique. Conclusion. Multiple-step polishing technique provided lower degree of discoloration for both composite resins. The final surface texture is material and technique dependent. PMID:21991483

  2. 5 CFR 1330.403 - System certification.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false System certification. 1330.403 Section 1330.403 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET JOINT REGULATIONS WITH THE OFFICE OF PERSONNEL MANAGEMENT HUMAN RESOURCES MANAGEMENT Performance Appraisal Certification for Pay Purposes § 1330...

  3. Well-posedness for a class of doubly nonlinear stochastic PDEs of divergence type

    NASA Astrophysics Data System (ADS)

    Scarpa, Luca

    2017-08-01

    We prove well-posedness for doubly nonlinear parabolic stochastic partial differential equations of the form dXt - div γ (∇Xt) dt + β (Xt) dt ∋ B (t ,Xt) dWt, where γ and β are the two nonlinearities, assumed to be multivalued maximal monotone operators everywhere defined on Rd and R respectively, and W is a cylindrical Wiener process. Using variational techniques, suitable uniform estimates (both pathwise and in expectation) and some compactness results, well-posedness is proved under the classical Leray-Lions conditions on γ and with no restrictive smoothness or growth assumptions on β. The operator B is assumed to be Hilbert-Schmidt and to satisfy some classical Lipschitz conditions in the second variable.

  4. Identifiability and Problems of Model Selection for Time-Series Analysis in Econometrics.

    DTIC Science & Technology

    1980-01-01

    Z is defined by (2.1) Fx + ( y( If x(t), T c R;dt for discrete-time, that is, with the time set T = Z = integers, a system F is given by * The...O1/14/81 cb (2.2) x(t + 1) Fx (t) + Gu(t), y(t) = Hx(t), t c Z. In (2.1-2.2), the real (or complex) vectors x, u, and y are called state, inpuI, and...compulsory. Astro - loryi has been tried. No optimist would quarrel with the declaration of one of von NE!MAfrIiI’s direct successors that "exposure to the

  5. Expert systems built by the Expert: An evaluation of OPS5

    NASA Technical Reports Server (NTRS)

    Jackson, Robert

    1987-01-01

    Two expert systems were written in OPS5 by the expert, a Ph.D. astronomer with no prior experience in artificial intelligence or expert systems, without the use of a knowledge engineer. The first system was built from scratch and uses 146 rules to check for duplication of scientific information within a pool of prospective observations. The second system was grafted onto another expert system and uses 149 additional rules to estimate the spacecraft and ground resources consumed by a set of prospective observations. The small vocabulary, the IF this occurs THEN do that logical structure of OPS5, and the ability to follow program execution allowed the expert to design and implement these systems with only the data structures and rules of another OPS5 system as an example. The modularity of the rules in OPS5 allowed the second system to modify the rulebase of the system onto which it was grafted without changing the code or the operation of that system. These experiences show that experts are able to develop their own expert systems due to the ease of programming and code reusability in OPS5.

  6. 18 CFR 301.5 - Changes in Average System Cost methodology.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Changes in Average System Cost methodology. 301.5 Section 301.5 Conservation of Power and Water Resources FEDERAL ENERGY... ACT § 301.5 Changes in Average System Cost methodology. (a) The Administrator, at his or her...

  7. 18 CFR 301.5 - Changes in Average System Cost methodology.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Changes in Average System Cost methodology. 301.5 Section 301.5 Conservation of Power and Water Resources FEDERAL ENERGY... ACT § 301.5 Changes in Average System Cost methodology. (a) The Administrator, at his or her...

  8. 18 CFR 301.5 - Changes in Average System Cost methodology.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Changes in Average System Cost methodology. 301.5 Section 301.5 Conservation of Power and Water Resources FEDERAL ENERGY... ACT § 301.5 Changes in Average System Cost methodology. (a) The Administrator, at his or her...

  9. 18 CFR 301.5 - Changes in Average System Cost methodology.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Changes in Average System Cost methodology. 301.5 Section 301.5 Conservation of Power and Water Resources FEDERAL ENERGY... ACT § 301.5 Changes in Average System Cost methodology. (a) The Administrator, at his or her...

  10. Thermophilic fermentation of acetoin and 2,3-butanediol by a novel Geobacillus strain

    PubMed Central

    2012-01-01

    Background Acetoin and 2,3-butanediol are two important biorefinery platform chemicals. They are currently fermented below 40°C using mesophilic strains, but the processes often suffer from bacterial contamination. Results This work reports the isolation and identification of a novel aerobic Geobacillus strain XT15 capable of producing both of these chemicals under elevated temperatures, thus reducing the risk of bacterial contamination. The optimum growth temperature was found to be between 45 and 55°C and the medium initial pH to be 8.0. In addition to glucose, galactose, mannitol, arabionose, and xylose were all acceptable substrates, enabling the potential use of cellulosic biomass as the feedstock. XT15 preferred organic nitrogen sources including corn steep liquor powder, a cheap by-product from corn wet-milling. At 55°C, 7.7 g/L of acetoin and 14.5 g/L of 2,3-butanediol could be obtained using corn steep liquor powder as a nitrogen source. Thirteen volatile products from the cultivation broth of XT15 were identified by gas chromatography–mass spectrometry. Acetoin, 2,3-butanediol, and their derivatives including a novel metabolite 2,3-dihydroxy-3-methylheptan-4-one, accounted for a total of about 96% of all the volatile products. In contrast, organic acids and other products were minor by-products. α-Acetolactate decarboxylase and acetoin:2,6-dichlorophenolindophenol oxidoreductase in XT15, the two key enzymes in acetoin metabolic pathway, were found to be both moderately thermophilic with the identical optimum temperature of 45°C. Conclusions Geobacillus sp. XT15 is the first naturally occurring thermophile excreting acetoin and/or 2,3-butanediol. This work has demonstrated the attractive prospect of developing it as an industrial strain in the thermophilic fermentation of acetoin and 2,3-butanediol with improved anti-contamination performance. The novel metabolites and enzymes identified in XT15 also indicated its strong promise as a precious

  11. A comparison of shear bond strength of orthodontic brackets bonded with four different orthodontic adhesives

    PubMed Central

    Sharma, Sudhir; Tandon, Pradeep; Nagar, Amit; Singh, Gyan P; Singh, Alka; Chugh, Vinay K

    2014-01-01

    Objectives: The objective of this study is to compare the shear bond strength (SBS) of stainless steel (SS) orthodontic brackets bonded with four different orthodontic adhesives. Materials and Methods: Eighty newly extracted premolars were bonded to 0.022 SS brackets (Ormco, Scafati, Italy) and equally divided into four groups based on adhesive used: (1) Rely-a-Bond (self-cure adhesive, Reliance Orthodontic Product, Inc., Illinois, USA), (2) Transbond XT (light-cure adhesive, 3M Unitek, CA, USA), (3) Transbond Plus (sixth generation self-etch primer, 3M Unitek, CA, USA) with Transbond XT (4) Xeno V (seventh generation self-etch primer, Dentsply, Konstanz, Germany) with Xeno Ortho (light-cure adhesive, Dentsply, Konstanz, Germany) adhesive. Brackets were debonded with a universal testing machine (Model No. 3382 Instron Corp., Canton, Mass, USA). The adhesive remnant index (ARI) was recordedIn addition, the conditioned enamel surfaces were observed under a scanning electron microscope (SEM). Results: Transbond XT (15.49 MPa) attained the highest bond strength. Self-etching adhesives (Xeno V, 13.51 MPa; Transbond Plus, 11.57 MPa) showed clinically acceptable SBS values and almost clean enamel surface after debonding. The analysis of variance (F = 11.85, P < 0.0001) and Chi-square (χ2 = 18.16, P < 0.05) tests revealed significant differences among groups. The ARI score of 3 (i.e., All adhesives left on the tooth) to be the most prevalent in Transbond XT (40%), followed by Rely-a-Bond (30%), Transbond Plus with Transbond XT (15%), and Xeno V with Xeno Ortho (10%). Under SEM, enamel surfaces after debonding of the brackets appeared porous when an acid-etching process was performed on the surfaces of Rely-a-Bond and Transbond XT, whereas with self-etching primers enamel presented smooth and almost clean surfaces (Transbond Plus and Xeno V group). Conclusion: All adhesives yielded SBS values higher than the recommended bond strength (5.9-7–8 MPa), Seventh generation

  12. 46 CFR 112.01-5 - Manual emergency lighting and power system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...

  13. 46 CFR 112.01-5 - Manual emergency lighting and power system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...

  14. 46 CFR 112.01-5 - Manual emergency lighting and power system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...

  15. 46 CFR 112.01-5 - Manual emergency lighting and power system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...

  16. 46 CFR 112.01-5 - Manual emergency lighting and power system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...

  17. 5 CFR 9901.405 - Performance management system requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Performance management system requirements. 9901.405 Section 9901.405 Administrative Personnel DEPARTMENT OF DEFENSE HUMAN RESOURCES MANAGEMENT AND LABOR RELATIONS SYSTEMS (DEPARTMENT OF DEFENSE-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF...

  18. Magnon modes and magnon-vortex scattering in two-dimensional easy-plane ferromagnets

    NASA Astrophysics Data System (ADS)

    Ivanov, B. A.; Schnitzer, H. J.; Mertens, F. G.; Wysin, G. M.

    1998-10-01

    We calculate the magnon modes in the presence of a vortex on a circular system, combining analytical calculations in the continuum limit with a numerical diagonalization of the discrete system. The magnon modes are expressed by the S matrix for magnon-vortex scattering, as a function of the parameters and the size of the system and for different boundary conditions. Certain quasilocal translational modes are identified with the frequencies which appear in the trajectory X-->(t) of the vortex center in recent molecular dynamics simulations of the full many-spin model. Using these quasilocal modes we calculate the two parameters of a third-order equation of motion for X-->(t). This equation was recently derived by a collective variable theory and describes very well the trajectories observed in the simulations. Both parameters, the vortex mass and the factor in front of X-->⃛, depend strongly on the boundary conditions.

  19. 5 CFR 838.911 - Identifying the retirement system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Identifying the retirement system. 838.911 Section 838.911 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE... Former Spouse Survivor Annuities Identification of Benefits § 838.911 Identifying the retirement system...

  20. 5 CFR 838.911 - Identifying the retirement system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Identifying the retirement system. 838.911 Section 838.911 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE... Former Spouse Survivor Annuities Identification of Benefits § 838.911 Identifying the retirement system...

  1. 5 CFR 838.911 - Identifying the retirement system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 2 2013-01-01 2013-01-01 false Identifying the retirement system. 838.911 Section 838.911 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE... Former Spouse Survivor Annuities Identification of Benefits § 838.911 Identifying the retirement system...

  2. 5 CFR 838.911 - Identifying the retirement system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 2 2012-01-01 2012-01-01 false Identifying the retirement system. 838.911 Section 838.911 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE... Former Spouse Survivor Annuities Identification of Benefits § 838.911 Identifying the retirement system...

  3. 5 CFR 838.911 - Identifying the retirement system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 2 2014-01-01 2014-01-01 false Identifying the retirement system. 838.911 Section 838.911 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE... Former Spouse Survivor Annuities Identification of Benefits § 838.911 Identifying the retirement system...

  4. 5 CFR 430.304 - SES performance management systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false SES performance management systems. 430.304 Section 430.304 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.304 SES performance management systems. (a...

  5. 5 CFR 843.210 - Transfers between retirement systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Transfers between retirement systems. 843.210 Section 843.210 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) FEDERAL EMPLOYEES RETIREMENT SYSTEM-DEATH BENEFITS AND EMPLOYEE REFUNDS One-time...

  6. 5 CFR 4001.105 - Purchase of System institution assets.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Purchase of System institution assets... SUPPLEMENTAL STANDARDS OF ETHICAL CONDUCT FOR EMPLOYEES OF THE FARM CREDIT SYSTEM INSURANCE CORPORATION § 4001.105 Purchase of System institution assets. (a) Prohibition on purchasing assets owned by a System...

  7. The extent of aortic annulus calcification is a predictor of postprocedural eccentricity and paravalvular regurgitation: a pre- and postinterventional cardiac computed tomography angiography study.

    PubMed

    Bekeredjian, Raffi; Bodingbauer, Dorothea; Hofmann, Nina P; Greiner, Sebastian; Schuetz, Moritz; Geis, Nicolas A; Kauczor, Hans U; Bryant, Mark; Chorianopoulos, Emmanuel; Pleger, Sven T; Mereles, Derliz; Katus, Hugo A; Korosoglou, Grigorios

    2015-03-01

    To investigate if the extent of aortic valve calcification is associated with postprocedural prosthesis eccentricity and paravalvular regurgitation (PAR) in patients undergoing transcatheter aortic valve implantation (TAVI). Cardiac computed tomography angiography (CCTA) was performed before and 3 months after TAVI in 46 patients who received the self-expanding CoreValve and in 22 patients who underwent balloon-expandable Edwards Sapien XT implantation. Aortic annulus calcification was measured with CCTA prior to TAVI and prosthesis eccentricity was assessed with post-TAVI CCTA. Standard echocardiography was also performed in all patients at 3-month follow-up exam. Annulus eccentricity was reduced during TAVI using both implantation systems (from 0.23 ± 0.06 to 0.18 ± 0.07 using CoreValve and from 0.20 ± 0.07 to 0.05 ± 0.03 using Edwards Sapien XT; P<.001 for both). With Edwards Sapien XT, eccentricity reduction at the level of the aortic annulus was significantly higher compared with CoreValve (P<.001). Annulus eccentricity after CoreValve use was significantly related to absolute valve calcification and to valve calcification indexed to body surface area (BSA) (r = 0.48 and 0.50, respectively; P<.001 for both). Furthermore, a significant association was observed between aortic valve calcification and PAR (P<.01 by ANOVA) in patients who received CoreValve. Using ROC analysis, a cut-off value over 913 mm² aortic valve calcification predicted the occurrence of moderate or severe PAR with a sensitivity of 92% and a specificity of 63% (area under the curve = 0.75). Furthermore, multivariable analysis showed that aortic valve calcification was a robust predictor of postprocedural eccentricity and PAR, independent of the aortic annulus size and native valve eccentricity and of CoreValve prosthesis size (adjusted r = 0.46 and 0.50, respectively; P<.01 for both). Such associations were not present with the Edwards Sapien XT system. The extent of native aortic

  8. 37 CFR 1.824 - Form and format for nucleotide and/or amino acid sequence submissions in computer readable form.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... which the data were recorded on the computer readable form, the operating system used, a reference... in a self-extracting format that will decompress on one of the systems described in paragraph (b) of... these format requirements: (1) Computer Compatibility: IBM PC/XT/AT or Apple Macintosh; (2) Operating...

  9. An intrinsic representation of atomic structure: From clusters to periodic systems

    NASA Astrophysics Data System (ADS)

    Li, Xiao-Tian; Xu, Shao-Gang; Yang, Xiao-Bao; Zhao, Yu-Jun

    2017-10-01

    We have improved our distance matrix and eigen-subspace projection function (EPF) [X.-T. Li et al., J. Chem. Phys. 146, 154108 (2017)] to describe the atomic structure for periodic systems. Depicting the local structure of an atom, the EPF turns out to be invariant with respect to the choices of the unit cell and coordinate frame, leading to an intrinsic representation of the crystal with a set of EPFs of the nontrivial atoms. The difference of EPFs reveals the difference of atoms in local structure, while the accumulated difference between two sets of EPFs can be taken as the distance between configurations. Exemplified with the cases of carbon allotropes and boron sheets, our EPF approach shows exceptional rationality and efficiency to distinguish the atomic structures, which is crucial in structure recognition, comparison, and analysis.

  10. An intrinsic representation of atomic structure: From clusters to periodic systems.

    PubMed

    Li, Xiao-Tian; Xu, Shao-Gang; Yang, Xiao-Bao; Zhao, Yu-Jun

    2017-10-14

    We have improved our distance matrix and eigen-subspace projection function (EPF) [X.-T. Li et al., J. Chem. Phys. 146, 154108 (2017)] to describe the atomic structure for periodic systems. Depicting the local structure of an atom, the EPF turns out to be invariant with respect to the choices of the unit cell and coordinate frame, leading to an intrinsic representation of the crystal with a set of EPFs of the nontrivial atoms. The difference of EPFs reveals the difference of atoms in local structure, while the accumulated difference between two sets of EPFs can be taken as the distance between configurations. Exemplified with the cases of carbon allotropes and boron sheets, our EPF approach shows exceptional rationality and efficiency to distinguish the atomic structures, which is crucial in structure recognition, comparison, and analysis.

  11. C-Language Integrated Production System, Version 5.1

    NASA Technical Reports Server (NTRS)

    Riley, Gary; Donnell, Brian; Ly, Huyen-Anh VU; Culbert, Chris; Savely, Robert T.; Mccoy, Daniel J.; Giarratano, Joseph

    1992-01-01

    CLIPS 5.1 provides cohesive software tool for handling wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming provides representation of knowledge by use of heuristics. Object-oriented programming enables modeling of complex systems as modular components. Procedural programming enables CLIPS to represent knowledge in ways similar to those allowed in such languages as C, Pascal, Ada, and LISP. Working with CLIPS 5.1, one can develop expert-system software by use of rule-based programming only, object-oriented programming only, procedural programming only, or combinations of the three.

  12. Evaluation of novel scoring system named 5-5-5 exacerbation grading scale for allergic conjunctivitis disease.

    PubMed

    Shoji, Jun; Inada, Noriko; Sawa, Mitsuru

    2009-12-01

    The objective of this study is to evaluate the practical usefulness of a scoring system using the 5-5-5 exacerbation grading scale for allergic conjunctivitis disease (ACD). Subjects were 103 patients with ACD including 40 patients with vernal keratoconjunctivitis (VKC), 20 patients with atopic keratoconjunctivitis (AKC), and 43 patients with allergic conjunctivitis (AC). The 5-5-5 exacerbation grading scale consists of the following 3 graded groups of clinical observations: the 100-point-grade group (100 points for each observation) includes active giant papillae, gelatinous infiltrates of the limbus, exfoliative epithelial keratopathy, shield ulcer and papillary proliferation at lower palpebral conjunctiva; the 10-point-grade group (10 points for each observation) includes blepharitis, papillary proliferation with velvety appearance, Horner-Trantas spots, edema of bulbal conjunctiva, and superficial punctate keratopathy; and the 1-point-grade group (1 point for each observation) includes papillae at upper palpebral conjunctiva, follicular lesion at lower palpebral conjunctiva, hyperemia of palpebral conjunctiva, hyperemia of bulbal conjunctiva, and lacrimal effusion. The total points in each grade group were determined as the severity score of the 5-5-5 exacerbation grading scale. The median severity scores of the 5-5-5 exacerbation grading scale in VKC, AKC and AC were 243 (range: 12-444), 32.5 (11-344), and 13 (2-33), respectively. The severity score of each ACD disease type was significantly different (P < 0.001, Kruskal-Wallis test). The severity of each type of ACD was classified as severe, moderate, or mild according to the severity score. The 5-5-5 exacerbation grading scale is a useful clinical tool for grading the severity of each type of ACD.

  13. 6 CFR 5.32 - Contracts for the operation of record systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Contracts for the operation of record systems. 5.32 Section 5.32 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY DISCLOSURE OF RECORDS AND INFORMATION Privacy Act § 5.32 Contracts for the operation of record systems. Under 5...

  14. Porting the AVS/Express scientific visualization software to Cray XT4.

    PubMed

    Leaver, George W; Turner, Martin J; Perrin, James S; Mummery, Paul M; Withers, Philip J

    2011-08-28

    Remote scientific visualization, where rendering services are provided by larger scale systems than are available on the desktop, is becoming increasingly important as dataset sizes increase beyond the capabilities of desktop workstations. Uptake of such services relies on access to suitable visualization applications and the ability to view the resulting visualization in a convenient form. We consider five rules from the e-Science community to meet these goals with the porting of a commercial visualization package to a large-scale system. The application uses message-passing interface (MPI) to distribute data among data processing and rendering processes. The use of MPI in such an interactive application is not compatible with restrictions imposed by the Cray system being considered. We present details, and performance analysis, of a new MPI proxy method that allows the application to run within the Cray environment yet still support MPI communication required by the application. Example use cases from materials science are considered.

  15. Systemic Manifestations in Pyridox(am)ine 5'-Phosphate Oxidase Deficiency.

    PubMed

    Guerriero, Réjean M; Patel, Archana A; Walsh, Brian; Baumer, Fiona M; Shah, Ankoor S; Peters, Jurriaan M; Rodan, Lance H; Agrawal, Pankaj B; Pearl, Phillip L; Takeoka, Masanori

    2017-11-01

    Pyridoxine is converted to its biologically active form pyridoxal-5-phosphate (P5P) by the enzyme pyridox(am)ine 5'-phosphate oxidase and serves as a cofactor in nearly 200 reactions in the central nervous system. Pyridox(am)ine 5'-phosphate oxidase deficiency leads to P5P dependent epilepsy, typically a neonatal- or infantile-onset epileptic encephalopathy treatable with P5P or in some cases, pyridoxine. Following identification of retinopathy in a patient with pyridox(am)ine 5'-phosphate oxidase deficiency that was reversible with P5P therapy, we describe the systemic manifestations of pyridox(am)ine 5'-phosphate oxidase deficiency. A series of six patients with homozygous mutations of PNPO, the gene coding pyridox(am)ine 5'-phosphate oxidase, were evaluated in our center over the course of two years for phenotyping of neurological and systemic manifestations. Five of six were born prematurely, three had anemia and failure to thrive, and two had elevated alkaline phosphatase. A movement disorder was observed in two children, and a reversible retinopathy was observed in the most severely affected infant. All patients had neonatal-onset epilepsy and were on a continuum of developmental delay to profound encephalopathy. Electroencephalographic features included background slowing and disorganization, absent sleep features, and multifocal and generalized epileptiform discharges. All the affected probands carried a homozygous PNPO mutation (c.674 G>T, c.686 G>A and c.352G>A). In addition to the well-described epileptic encephalopathy, pyridox(am)ine 5'-phosphate oxidase deficiency causes a range of neurological and systemic manifestations. A movement disorder, developmental delay, and encephalopathy, as well as retinopathy, anemia, and failure to thrive add to the broadening clinical spectrum of P5P dependent epilepsy. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. 10 CFR 960.5-1 - System guidelines.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REPOSITORY Preclosure Guidelines § 960.5-1 System guidelines. (a) Qualifying conditions—(1) Preclosure... radioactive materials to restricted and unrestricted areas during repository operation and closure shall meet... repository siting, construction, operation, closure, and decommissioning the public and the environment shall...

  17. 40 CFR 61.242-5 - Standards: Sampling connecting systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Standards: Sampling connecting systems... for Equipment Leaks (Fugitive Emission Sources) § 61.242-5 Standards: Sampling connecting systems. (a) Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed vent...

  18. 5 CFR 4101.105 - Purchase of System institution assets.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... ETHICAL CONDUCT FOR EMPLOYEES OF THE FARM CREDIT ADMINISTRATION § 4101.105 Purchase of System institution assets. (a) Prohibition on purchasing assets owned by a System institution. No covered employee, or... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Purchase of System institution assets...

  19. Physicochemical Properties of α-Form Hydrated Crystalline Phase of 3-(10-Carboxydecyl)-1,1,1,3,5,5,5-heptamethyl Trisiloxane/Higher alcohol/Polyoxyethylene (5 mol) Glyceryl monostearate/Water System.

    PubMed

    Uyama, Makoto; Araki, Hidefumi; Fukuhara, Tadao; Watanabe, Kei

    2018-06-07

    The α-form hydrated crystalline phase (often called as an α-gel) is one of the hydrated crystalline phases which can be exhibited by surfactants and lipids. In this study, a novel system of an α-form hydrated crystal was developed, composed of 3-(10-carboxydecyl)-1,1,1,3,5,5,5-heptamethyl trisiloxane (CDTS), polyoxyethylene (5 mol) glyceryl monostearate (GMS-5), higher alcohol. This is the first report to indicate that a silicone surfactant can form an α-form hydrated crystal. The physicochemical properties of this system were characterized by small and wide angle X-ray scattering (SWAXS), differential scanning calorimetry (DSC), and diffusion-ordered NMR spectroscopy (DOSY) experiments. SWAXS and DSC measurements revealed that a plurality of crystalline phases coexist in the CDTS/higher alcohol/water ternary system. By adding GMS-5 to the ternary system, however, a wide region of a single α-form hydrated crystalline phase was obtained. The self-diffusion coefficients (D sel ) from the NMR measurements suggested that all of the CDTS, GMS-5, and higher alcohol molecules were incorporated into the same α-form hydrated crystals.

  20. The advanced progress of precoding technology in 5g system

    NASA Astrophysics Data System (ADS)

    An, Chenyi

    2017-09-01

    With the development of technology, people began to put forward higher requirements for the mobile system, the emergence of the 5G subvert the track of the development of mobile communication technology. In the research of the core technology of 5G mobile communication, large scale MIMO, and precoding technology is a research hotspot. At present, the research on precoding technology in 5G system analyzes the various methods of linear precoding, the maximum ratio transmission (MRT) precoding algorithm, zero forcing (ZF) precoding algorithm, minimum mean square error (MMSE) precoding algorithm based on maximum signal to leakage and noise ratio (SLNR). Precoding algorithms are analyzed and summarized in detail. At the same time, we also do some research on nonlinear precoding methods, such as dirty paper precoding, THP precoding algorithm and so on. Through these analysis, we can find the advantages and disadvantages of each algorithm, as well as the development trend of each algorithm, grasp the development of the current 5G system precoding technology. Therefore, the research results and data of this paper can be used as reference for the development of precoding technology in 5G system.

  1. 49 CFR 173.5b - Portable and mobile refrigeration systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Portable and mobile refrigeration systems. 173.5b...-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS General § 173.5b Portable and mobile refrigeration... refrigeration systems, which may or may not be permanently mounted to a transport vehicle, used for agricultural...

  2. 49 CFR 173.5b - Portable and mobile refrigeration systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Portable and mobile refrigeration systems. 173.5b...-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS General § 173.5b Portable and mobile refrigeration... refrigeration systems, which may or may not be permanently mounted to a transport vehicle, used for agricultural...

  3. 49 CFR 173.5b - Portable and mobile refrigeration systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Portable and mobile refrigeration systems. 173.5b...-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS General § 173.5b Portable and mobile refrigeration... refrigeration systems, which may or may not be permanently mounted to a transport vehicle, used for agricultural...

  4. Sparse Bayesian Information Filters for Localization and Mapping

    DTIC Science & Technology

    2008-02-01

    a set of smaller, more manageable maps [76, 51, 139, 77, 12]. These appropriately-named submap algorithms greatly reduce the effects of map size on...An intuitive way of dealing with this limitation is to divide the world into numerous sub-environments, each comprised of a more manageable number of...p (xt, M I z t , u t) = p (M I xt, zt) • p (xt zt, ut) (2.16) 6 This assumes knowledge of the mean, which is necessary for observations that are

  5. 5 CFR 930.301 - Information systems security awareness training program.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ....g., system and network administrators, and system/application security officers) must receive... 5 Administrative Personnel 2 2013-01-01 2013-01-01 false Information systems security awareness... (MISCELLANEOUS) Information Security Responsibilities for Employees who Manage or Use Federal Information Systems...

  6. 5 CFR 930.301 - Information systems security awareness training program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ....g., system and network administrators, and system/application security officers) must receive... 5 Administrative Personnel 2 2014-01-01 2014-01-01 false Information systems security awareness... (MISCELLANEOUS) Information Security Responsibilities for Employees who Manage or Use Federal Information Systems...

  7. Development of a personal-computer-based intelligent tutoring system

    NASA Technical Reports Server (NTRS)

    Mueller, Stephen J.

    1988-01-01

    A large number of Intelligent Tutoring Systems (ITSs) have been built since they were first proposed in the early 1970's. Research conducted on the use of the best of these systems has demonstrated their effectiveness in tutoring in selected domains. A prototype ITS for tutoring students in the use of CLIPS language: CLIPSIT (CLIPS Intelligent Tutor) was developed. For an ITS to be widely accepted, not only must it be effective, flexible, and very responsive, it must also be capable of functioning on readily available computers. While most ITSs have been developed on powerful workstations, CLIPSIT is designed for use on the IBM PC/XT/AT personal computer family (and their clones). There are many issues to consider when developing an ITS on a personal computer such as the teaching strategy, user interface, knowledge representation, and program design methodology. Based on experiences in developing CLIPSIT, results on how to address some of these issues are reported and approaches are suggested for maintaining a powerful learning environment while delivering robust performance within the speed and memory constraints of the personal computer.

  8. Microtensile bond strength of three simplified adhesive systems to caries-affected dentin.

    PubMed

    Scholtanus, J D; Purwanta, Kenny; Dogan, Nilgun; Kleverlaan, Cees J; Feilzer, Albert J

    2010-08-01

    The purpose of the study was to determine the microtensile bond strength of three different simplified adhesive systems to caries-affected dentin. Fifteen extracted human molars with primary carious lesions were ground flat until dentin was exposed. Soft caries-infected dentin was excavated with the help of caries detector dye. On the remaining hard dentin, a standardized smear layer was created by polishing with 600-grit SiC paper. Teeth were divided into three groups and treated with one of the three tested adhesives: Adper Scotchbond 1 XT (3M ESPE), a 2-step etch-andrinse adhesive, Clearfil S3 Bond (Kuraray), a 1-step self-etching or all-in-one adhesive, and Clearfil SE Bond (Kuraray), a 2-step self-etching adhesive. Five-mm-thick composite buildups (Z-250, 3M ESPE) were built and light cured. After water storage for 24 h at 37ºC, the bonded specimens were sectioned into bars (1.0 x 1.0 mm; n = 20 to 30). Microtensile bond strength of normal dentin specimens and caries-affected dentin specimens was measured in a universal testing machine (crosshead speed = 1 mm/min). Data were analyzed using two-way ANOVA and Tukey's post-hoc test (p < 0.05). No significant differences in bond strength values to normal dentin between the three adhesives were found. Adper Scotchbond 1 XT and Clearfil S3 Bond showed significantly lower bond strength values to caries-affected dentin. For Clearfil SE Bond, bond strength values to normal and caries-affected dentin were not significantly different. All the tested simplified adhesives showed similar bond strength values to normal dentin. For the tested 2-step etch-and-rinse adhesive and the all-in-one adhesive, the bond strength values to caries-affected dentin were lower than to normal dentin.

  9. A Compact X-Ray System for Macromolecular Crystallography. 5

    NASA Technical Reports Server (NTRS)

    Gubarev, Mikhail; Ciszak, Ewa; Ponomarev, Igor; Joy, Marshall

    2000-01-01

    We describe the design and performance of a high flux x-ray system for macromolecular crystallography that combines a microfocus x-ray generator (40 gm FWHM spot size at a power level of 46.5Watts) and a 5.5 mm focal distance polycapillary optic. The Cu K(sub alpha) X-ray flux produced by this optimized system is 7.0 times above the X-ray flux previously reported. The X-ray flux from the microfocus system is also 3.2 times higher than that produced by the rotating anode generator equipped with a long focal distance graded multilayer monochromator (Green optic; CMF24-48-Cu6) and 30% less than that produced by the rotating anode generator with the newest design of graded multilayer monochromator (Blue optic; CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 Watts, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42,540 reflections collected at ambient temperature from a lysozyme crystal yielded R(sub sym) 5.0% for the data extending to 1.7A, and 4.8% for the complete set of data to 1.85A. The amplitudes of the reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model.

  10. 5 CFR 297.103 - Designations of authority by system manager.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Designations of authority by system manager. 297.103 Section 297.103 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE... system manager. The responsible Office system manager having jurisdiction over a system of records may...

  11. Dietary supplementation of young broiler chickens with Capsicum and turmeric oleoresins increases resistance to necrotic enteritis

    USDA-ARS?s Scientific Manuscript database

    The Clostridium-related poultry disease, necrotic enteritis (NE), causes substantial economic losses on a global scale. In this study, a mixture of two plant-derived phytonutrients, Capsicum oleoresin and turmeric oleoresin (XT), was evaluated for its effects on local and systemic immune responses ...

  12. Dietary supplementation of young broiler chickens with capsicum and turmeric oleoresin increases resistance to necrotic enteris

    USDA-ARS?s Scientific Manuscript database

    The Clostridium-related poultry disease, necrotic enteritis (NE), causes substantial economic losses on a global scale. In this study, a mixture of two plant-derived phytonutrients, Capsicum oleoresin and turmeric oleoresin (XT), was evaluated for its effects on local and systemic immune responses ...

  13. Optimization of degradation of Reactive Black 5 (RB5) and electricity generation in solar photocatalytic fuel cell system.

    PubMed

    Khalik, Wan Fadhilah; Ho, Li-Ngee; Ong, Soon-An; Voon, Chun-Hong; Wong, Yee-Shian; Yusoff, NikAthirah; Lee, Sin-Li; Yusuf, Sara Yasina

    2017-10-01

    The photocatalytic fuel cell (PFC) system was developed in order to study the effect of several operating parameters in degradation of Reactive Black 5 (RB5) and its electricity generation. Light irradiation, initial dye concentration, aeration, pH and cathode electrode are the operating parameters that might give contribution in the efficiency of PFC system. The degradation of RB5 depends on the presence of light irradiation and solar light gives better performance to degrade the azo dye. The azo dye with low initial concentration decolorizes faster compared to higher initial concentration and presence of aeration in PFC system would enhance its performance. Reactive Black 5 rapidly decreased at higher pH due to the higher amount of OH generated at higher pH and Pt-loaded carbon (Pt/C) was more suitable to be used as cathode in PFC system compared to Cu foil and Fe foil. The rapid decolorization of RB5 would increase their voltage output and in addition, it would also increase their V oc , J sc and P max . The breakage of azo bond and aromatic rings was confirmed through UV-Vis spectrum and COD analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Latino children's body mass index at 2-3.5 years predicts sympathetic nervous system activity at 5 years.

    PubMed

    Alkon, Abbey; Harley, Kim G; Neilands, Torsten B; Tambellini, Katelyn; Lustig, Robert H; Boyce, W Thomas; Eskenazi, Brenda

    2014-06-01

    To understand whether the relationship between young children's autonomic nervous system (ANS) responses predicted their BMI, or vice versa, the association between standardized BMI (zBMI) at 2, 3.5, and 5 years of age and ANS reactivity at 3.5-5 years of age, and whether zBMI predicts later ANS reactivity or whether early ANS reactivity predicts later zBMI, was studied. Low-income, primarily Latino children (n=112) were part of a larger cohort study of mothers recruited during early pregnancy. Study measures included maternal prenatal weight, children's health behaviors (i.e., time watching television, fast food consumption, and time playing outdoors), children's height and weight at 2, 3.5, and 5 years, and children's ANS reactivity at 3.5 and 5 years. ANS measures of sympathetic nervous system (i.e., pre-ejection period) and parasympathetic nervous system (i.e., respiratory sinus arrhythmia) activity were monitored during rest and four challenges. Reactivity was calculated as the difference between mean challenge response and rest. Structural equation models analyzed the relationship between children's zBMI at 2, 3.5, and 5 years and ANS reactivity at 3.5 and 5 years, adjusting for mother's BMI, children's behaviors, and changes in height. There was no association between zBMI and ANS cross-sectionally. Children with high zBMI at 2 or 3.5 years or large zBMI increases from 2 to 3.5 years of age had decreased sympathetic activity at 5 years. Neither sympathetic nor parasympathetic reactivity at 3.5 years predicted later zBMI. Increased zBMI early in childhood may dampen young children's SNS responses later in life.

  15. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF TECHNOLOGIES FOR MEASURING TRACE ELEMENTS IN SOIL AND SEDIMENT XCALIBUR ELVAX XRF ANALYZER

    EPA Science Inventory

    The Innov-X XT400 Series (XT400) x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kenned...

  16. Indomethacin-5-fluorouracil-methyl ester dry emulsion: a potential oral delivery system for 5-fluorouracil.

    PubMed

    Wang, Jing; Hu, Yanchen; Li, Ling; Jiang, Tongying; Wang, Siling; Mo, Fengkui

    2010-06-01

    To produce a combined effect of indomethacin (IDM) and 5-fluorouracil (5FU) for cancer therapy, the side effects of IDM on the gastrointestinal (GI) tract were reduced and the oral adsorption of 5FU was improved. Indomethacin-5-fluorouracil-methyl ester (IFM) dry emulsion was prepared and evaluated as a potential oral delivery system for 5FU. IFM was synthesized by formation of an ester between IDM and 5FU intermediate and then characterized by structure, melting point, solubility, apparent partition coefficient, and incubation with GI tract contents and plasma. Gum acacia and sodium carboxymethyl cellulose (CMC-Na) were applied as the adsorbent and solid carrier to prepare IFM dry emulsion. IFM dry emulsion was then characterized by reconstitution in water and in situ intestinal perfusion experiment. Physicochemical properties of the new synthesized compound confirmed the formation of IFM. Incubation of IFM in the contents of the GI tract and plasma revealed that IFM was not relatively stable in GI contents during the time period of transit through the GI tract, whereas it was very unstable in plasma and released 5FU rapidly. The IFM dry emulsion could be easily reconstituted in water, and the mean particle size was 2.416 microm. The absorption rate constant (K) for IFM with concentration of 2, 5, and 10 microg/mL in the in situ perfusion experiment were 0.473, 0.423, and 0.433/h, respectively, demonstrating passive diffusion of IFM across the biological membranes. This study indicates that the IFM dry emulsion may represent a potentially useful oral delivery system for 5FU.

  17. The open quantum Brownian motions

    NASA Astrophysics Data System (ADS)

    Bauer, Michel; Bernard, Denis; Tilloy, Antoine

    2014-09-01

    Using quantum parallelism on random walks as the original seed, we introduce new quantum stochastic processes, the open quantum Brownian motions. They describe the behaviors of quantum walkers—with internal degrees of freedom which serve as random gyroscopes—interacting with a series of probes which serve as quantum coins. These processes may also be viewed as the scaling limit of open quantum random walks and we develop this approach along three different lines: the quantum trajectory, the quantum dynamical map and the quantum stochastic differential equation. We also present a study of the simplest case, with a two level system as an internal gyroscope, illustrating the interplay between the ballistic and diffusive behaviors at work in these processes. Notation H_z : orbital (walker) Hilbert space, {C}^{{Z}} in the discrete, L^2({R}) in the continuum H_c : internal spin (or gyroscope) Hilbert space H_sys=H_z\\otimesH_c : system Hilbert space H_p : probe (or quantum coin) Hilbert space, H_p={C}^2 \\rho^tot_t : density matrix for the total system (walker + internal spin + quantum coins) \\bar \\rho_t : reduced density matrix on H_sys : \\bar\\rho_t=\\int dxdy\\, \\bar\\rho_t(x,y)\\otimes | x \\rangle _z\\langle y | \\hat \\rho_t : system density matrix in a quantum trajectory: \\hat\\rho_t=\\int dxdy\\, \\hat\\rho_t(x,y)\\otimes | x \\rangle _z\\langle y | . If diagonal and localized in position: \\hat \\rho_t=\\rho_t\\otimes| X_t \\rangle _z\\langle X_t | ρt: internal density matrix in a simple quantum trajectory Xt: walker position in a simple quantum trajectory Bt: normalized Brownian motion ξt, \\xi_t^\\dagger : quantum noises

  18. Tuning HDF5 subfiling performance on parallel file systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byna, Suren; Chaarawi, Mohamad; Koziol, Quincey

    Subfiling is a technique used on parallel file systems to reduce locking and contention issues when multiple compute nodes interact with the same storage target node. Subfiling provides a compromise between the single shared file approach that instigates the lock contention problems on parallel file systems and having one file per process, which results in generating a massive and unmanageable number of files. In this paper, we evaluate and tune the performance of recently implemented subfiling feature in HDF5. In specific, we explain the implementation strategy of subfiling feature in HDF5, provide examples of using the feature, and evaluate andmore » tune parallel I/O performance of this feature with parallel file systems of the Cray XC40 system at NERSC (Cori) that include a burst buffer storage and a Lustre disk-based storage. We also evaluate I/O performance on the Cray XC30 system, Edison, at NERSC. Our results show performance benefits of 1.2X to 6X performance advantage with subfiling compared to writing a single shared HDF5 file. We present our exploration of configurations, such as the number of subfiles and the number of Lustre storage targets to storing files, as optimization parameters to obtain superior I/O performance. Based on this exploration, we discuss recommendations for achieving good I/O performance as well as limitations with using the subfiling feature.« less

  19. 5 CFR 9901.371 - Conversion into NSPS pay system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 3 2011-01-01 2011-01-01 false Conversion into NSPS pay system. 9901.371... SECURITY PERSONNEL SYSTEM (NSPS) Pay and Pay Administration Conversion Provisions § 9901.371 Conversion....231 for conversion rules related to determining an employee's career group, pay schedule, and band...

  20. A Multicenter Performance Evaluation of a Blood Glucose Monitoring System in 21 Leading Hospitals in Spain

    PubMed Central

    Bedini, José Luis; Wallace, Jane F.; Petruschke, Thorsten; Pardo, Scott

    2015-01-01

    Background: Self-monitoring of blood glucose is crucial for the effective self-management of diabetes. The present study evaluated the accuracy of the Contour® XT blood glucose monitoring system (BGMS) compared to the reference method in a large multicenter study under routine lab conditions at each hospital site. Methods: This study was conducted at 21 leading hospitals in Spain using leftover whole blood samples (n = 2100). Samples were tested with the BGMS using 1 commercial strip lot and the local laboratory hexokinase method. BGMS accuracy was assessed and results were compared to ISO 15197:2013 accuracy limit criteria and by using mean absolute relative difference analysis (MARD), consensus (Parkes) error grid (CEG), and surveillance error grid analyses (SEG). Results: Pooled analysis of 2100 measurements from all sites showed that 99.43% of the BGMS results were within the ranges accepted by the accuracy limit criteria. The overall MARD was 3.85%. MARD was 4.47% for glucose concentrations < 70 mg/dL and 3.81% for concentrations of 70-300 mg/dL. In CEG, most results (99.8%) were within zone A (“no effect on clinical action”); the remaining ones (0.2%) were in zone B (“little to no effect on clinical action”). The SEG analysis showed that most of the results (98.4%) were in the “no risk” zone, with the remaining results in the “slight, lower” risk zone. Conclusions: This is the largest multicenter study of Contour XT BGMS to date, and shows that this BGMS meets the ISO 15197:2013 accuracy limit criteria under local routine conditions in 21 leading Spanish hospitals. PMID:26253142

  1. A Multicenter Performance Evaluation of a Blood Glucose Monitoring System in 21 Leading Hospitals in Spain.

    PubMed

    Bedini, José Luis; Wallace, Jane F; Petruschke, Thorsten; Pardo, Scott

    2015-08-07

    Self-monitoring of blood glucose is crucial for the effective self-management of diabetes. The present study evaluated the accuracy of the Contour® XT blood glucose monitoring system (BGMS) compared to the reference method in a large multicenter study under routine lab conditions at each hospital site. This study was conducted at 21 leading hospitals in Spain using leftover whole blood samples (n = 2100). Samples were tested with the BGMS using 1 commercial strip lot and the local laboratory hexokinase method. BGMS accuracy was assessed and results were compared to ISO 15197:2013 accuracy limit criteria and by using mean absolute relative difference analysis (MARD), consensus (Parkes) error grid (CEG), and surveillance error grid analyses (SEG). Pooled analysis of 2100 measurements from all sites showed that 99.43% of the BGMS results were within the ranges accepted by the accuracy limit criteria. The overall MARD was 3.85%. MARD was 4.47% for glucose concentrations < 70 mg/dL and 3.81% for concentrations of 70-300 mg/dL. In CEG, most results (99.8%) were within zone A ("no effect on clinical action"); the remaining ones (0.2%) were in zone B ("little to no effect on clinical action"). The SEG analysis showed that most of the results (98.4%) were in the "no risk" zone, with the remaining results in the "slight, lower" risk zone. This is the largest multicenter study of Contour XT BGMS to date, and shows that this BGMS meets the ISO 15197:2013 accuracy limit criteria under local routine conditions in 21 leading Spanish hospitals. © 2015 Diabetes Technology Society.

  2. The USL NASA PC R and D project: General specifications of objectives

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor)

    1984-01-01

    Given here are the general specifications of the objectives of the University of Southwestern Louisiana Data Base Management System (USL/DBMS) NASA PC R and D Project, a project initiated to address future R and D issues related to PC-based processing environments acquired pursuant to the NASA contract work; namely, the IBM PC/XT systems.

  3. Approximating Smooth Step Functions Using Partial Fourier Series Sums

    DTIC Science & Technology

    2012-09-01

    interp1(xt(ii), smoothstepbez( t(ii), min(t(ii)), max(t(ii)), ’y’), t(ii), ’linear’, ’ extrap ’); ii = find( abs(t - tau/2) <= epi ); iii = t(ii...interp1( xt(ii), smoothstepbez( rt, min(rt), max(rt), ’y’), t(ii), ’linear’, ’ extrap ’ ); % stepm(ii) = 1 - interp1(xt(ii), smoothstepbez( t(ii...min(t(ii)), max(t(ii)), ’y’), t(ii), ’linear’, ’ extrap ’); In this case, because x is also defined as a function of the independent parameter

  4. 49 CFR 570.5 - Service brake system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... force applied by the brake on a front wheel or a rear wheel shall not differ by more than 20 percent from the force applied by the brake on the other front wheel or the other rear wheel respectively. (i... Pounds or Less § 570.5 Service brake system. Unless otherwise noted, the force to be applied during...

  5. 49 CFR 570.5 - Service brake system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... force applied by the brake on a front wheel or a rear wheel shall not differ by more than 20 percent from the force applied by the brake on the other front wheel or the other rear wheel respectively. (i... Pounds or Less § 570.5 Service brake system. Unless otherwise noted, the force to be applied during...

  6. 49 CFR 570.5 - Service brake system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... force applied by the brake on a front wheel or a rear wheel shall not differ by more than 20 percent from the force applied by the brake on the other front wheel or the other rear wheel respectively. (i... Pounds or Less § 570.5 Service brake system. Unless otherwise noted, the force to be applied during...

  7. Multi-Scale Correlative Tomography of a Li-Ion Battery Composite Cathode

    PubMed Central

    Moroni, Riko; Börner, Markus; Zielke, Lukas; Schroeder, Melanie; Nowak, Sascha; Winter, Martin; Manke, Ingo; Zengerle, Roland; Thiele, Simon

    2016-01-01

    Focused ion beam/scanning electron microscopy tomography (FIB/SEMt) and synchrotron X-ray tomography (Xt) are used to investigate the same lithium manganese oxide composite cathode at the same specific spot. This correlative approach allows the investigation of three central issues in the tomographic analysis of composite battery electrodes: (i) Validation of state-of-the-art binary active material (AM) segmentation: Although threshold segmentation by standard algorithms leads to very good segmentation results, limited Xt resolution results in an AM underestimation of 6 vol% and severe overestimation of AM connectivity. (ii) Carbon binder domain (CBD) segmentation in Xt data: While threshold segmentation cannot be applied for this purpose, a suitable classification method is introduced. Based on correlative tomography, it allows for reliable ternary segmentation of Xt data into the pore space, CBD, and AM. (iii) Pore space analysis in the micrometer regime: This segmentation technique is applied to an Xt reconstruction with several hundred microns edge length, thus validating the segmentation of pores within the micrometer regime for the first time. The analyzed cathode volume exhibits a bimodal pore size distribution in the ranges between 0–1 μm and 1–12 μm. These ranges can be attributed to different pore formation mechanisms. PMID:27456201

  8. Gli3-mediated somitic Fgf10 expression gradients are required for the induction and patterning of mammary epithelium along the embryonic axes.

    PubMed

    Veltmaat, Jacqueline M; Relaix, Frédéric; Le, Lendy T; Kratochwil, Klaus; Sala, Frédéric G; van Veelen, Wendy; Rice, Ritva; Spencer-Dene, Bradley; Mailleux, Arnaud A; Rice, David P; Thiery, Jean Paul; Bellusci, Saverio

    2006-06-01

    Little is known about the regulation of cell fate decisions that lead to the formation of five pairs of mammary placodes in the surface ectoderm of the mouse embryo. We have previously shown that fibroblast growth factor 10 (FGF10) is required for the formation of mammary placodes 1, 2, 3 and 5. Here, we have found that Fgf10 is expressed only in the somites underlying placodes 2 and 3, in gradients across and within these somites. To test whether somitic FGF10 is required for the formation of these two placodes, we analyzed a number of mutants with different perturbations of somitic Fgf10 gradients for the presence of WNT signals and ectodermal multilayering, markers for mammary line and placode formation. The mammary line is displaced dorsally, and formation of placode 3 is impaired in Pax3ILZ/ILZ mutants, which do not form ventral somitic buds. Mammary line formation is impaired and placode 3 is absent in Gli3Xt-J/Xt-J and hypomorphic Fgf10 mutants, in which the somitic Fgf10 gradient is shortened dorsally and less overall Fgf10 is expressed, respectively. Recombinant FGF10 rescued mammogenesis in Fgf10(-/-) and Gli3Xt-J/Xt-J flanks. We correlate increasing levels of somitic FGF10 with progressive maturation of the surface ectoderm, and show that full expression of somitic Fgf10, co-regulated by GLI3, is required for the anteroposterior pattern in which the flank ectoderm acquires a mammary epithelial identity. We propose that the intra-somitic Fgf10 gradient, together with ventral elongation of the somites, determines the correct dorsoventral position of mammary epithelium along the flank.

  9. 21 CFR 862.1520 - 5′-Nucleotidase test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false 5â²-Nucleotidase test system. 862.1520 Section 862.1520 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862...

  10. Large space telescope, phase A. Volume 5: Support systems module

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The development and characteristics of the support systems module for the Large Space Telescope are discussed. The following systems and described: (1) thermal control, (2) electrical, (3) communication and data landing, (4) attitude control system, and (5) structural features. Analyses of maintainability and reliability considerations are included.

  11. 28 CFR 25.5 - Validation and data integrity of records in the system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 1 2011-07-01 2011-07-01 false Validation and data integrity of records in the system. 25.5 Section 25.5 Judicial Administration DEPARTMENT OF JUSTICE DEPARTMENT OF JUSTICE INFORMATION SYSTEMS The National Instant Criminal Background Check System § 25.5 Validation and data integrity...

  12. 28 CFR 25.5 - Validation and data integrity of records in the system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 1 2013-07-01 2013-07-01 false Validation and data integrity of records in the system. 25.5 Section 25.5 Judicial Administration DEPARTMENT OF JUSTICE DEPARTMENT OF JUSTICE INFORMATION SYSTEMS The National Instant Criminal Background Check System § 25.5 Validation and data integrity...

  13. 28 CFR 25.5 - Validation and data integrity of records in the system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 1 2012-07-01 2012-07-01 false Validation and data integrity of records in the system. 25.5 Section 25.5 Judicial Administration DEPARTMENT OF JUSTICE DEPARTMENT OF JUSTICE INFORMATION SYSTEMS The National Instant Criminal Background Check System § 25.5 Validation and data integrity...

  14. 28 CFR 25.5 - Validation and data integrity of records in the system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 1 2014-07-01 2014-07-01 false Validation and data integrity of records in the system. 25.5 Section 25.5 Judicial Administration DEPARTMENT OF JUSTICE DEPARTMENT OF JUSTICE INFORMATION SYSTEMS The National Instant Criminal Background Check System § 25.5 Validation and data integrity...

  15. 75 FR 17434 - In the Matter of Certain Personal Data and Mobile Communications Devices and Related Software...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-06

    ... Mobile Communications Devices and Related Software; Notice of Investigation AGENCY: U.S. International... Apple Computer, Inc. of Cupertino, California and NeXT Software, Inc. f/k/a NeXT Computer, Inc. of... certain personal data and mobile communications devices and related software by reason of infringement of...

  16. 40 CFR 60.482-5a - Standards: Sampling connection systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards: Sampling connection systems..., Reconstruction, or Modification Commenced After November 7, 2006 § 60.482-5a Standards: Sampling connection systems. (a) Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed...

  17. 40 CFR 60.482-5a - Standards: Sampling connection systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Sampling connection systems..., Reconstruction, or Modification Commenced After November 7, 2006 § 60.482-5a Standards: Sampling connection systems. (a) Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed...

  18. The impact of PM2.5 on the human respiratory system.

    PubMed

    Xing, Yu-Fei; Xu, Yue-Hua; Shi, Min-Hua; Lian, Yi-Xin

    2016-01-01

    Recently, many researchers paid more attentions to the association between air pollution and respiratory system disease. In the past few years, levels of smog have increased throughout China resulting in the deterioration of air quality, raising worldwide concerns. PM2.5 (particles less than 2.5 micrometers in diameter) can penetrate deeply into the lung, irritate and corrode the alveolar wall, and consequently impair lung function. Hence it is important to investigate the impact of PM2.5 on the respiratory system and then to help China combat the current air pollution problems. In this review, we will discuss PM2.5 damage on human respiratory system from epidemiological, experimental and mechanism studies. At last, we recommend to the population to limit exposure to air pollution and call to the authorities to create an index of pollution related to health.

  19. 30 CFR 75.1101-5 - Installation of foam generator systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Installation of foam generator systems. 75.1101...-5 Installation of foam generator systems. (a) Foam generator systems shall be located so as to discharge foam to the belt drive, belt takeup, electrical controls, gear reducing unit and the conveyor belt...

  20. 46 CFR 34.05-5 - Fire-extinguishing systems-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Officer in Charge, Marine Inspection. (1) Dry cargo compartments. A carbon dioxide or water spray system... subparagraph. (3) Lamp and paint lockers and similar spaces. A carbon dioxide or water spray system must be..., inert gas, foam or water spray system must be installed for the protection of all pumprooms. (5...

  1. 46 CFR 34.05-5 - Fire-extinguishing systems-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Officer in Charge, Marine Inspection. (1) Dry cargo compartments. A carbon dioxide or water spray system... subparagraph. (3) Lamp and paint lockers and similar spaces. A carbon dioxide or water spray system must be..., inert gas, foam or water spray system must be installed for the protection of all pumprooms. (5...

  2. 46 CFR 193.10-5 - Fire main system, details.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Fire main system, details. 193.10-5 Section 193.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE... 21/2 2 7/8 2 50 1 On vessels of 65 feet in length or less, 3/4-inch hose of good commercial grade...

  3. 46 CFR 193.10-5 - Fire main system, details.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Fire main system, details. 193.10-5 Section 193.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE... 21/2 2 7/8 2 50 1 On vessels of 65 feet in length or less, 3/4-inch hose of good commercial grade...

  4. 46 CFR 193.10-5 - Fire main system, details.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Fire main system, details. 193.10-5 Section 193.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE... 21/2 2 7/8 2 50 1 On vessels of 65 feet in length or less, 3/4-inch hose of good commercial grade...

  5. Transcatheter aortic valve implantation transapical: step by step.

    PubMed

    Walther, Thomas; Möllmann, Helge; van Linden, Arnaud; Kempfert, Jörg

    2011-01-01

    Transcatheter aortic valve implantation (T-AVI) has been introduced into clinical practice to treat high-risk elderly patients with aortic stenosis. T-AVI can be performed by using a retrograde transfemoral (TF), transsubclavian, transaortic, and/or antegrade transapical (TA) approach. For TA-AVI, CE mark approval was granted in 2008 for the Edwards SAPIEN (Edwards Lifesciences, Irvine, CA) prosthesis with the Ascendra delivery system and in 2010 for the second-generation Edwards SAPIEN XT prosthesis and the Ascendra II delivery system, with 23-mm and 26-mm valves. In 2011, CE mark approval has been granted for TA-AVI by using the SAPIEN XT 29-mm prosthesis. Several other devices from different companies (Jenavalve, Jena Valve Inc, Munich, Germany; Embracer, Medtronic Inc, Guilford, CT; Accurate, Symetis Inc, Geneva, Switzerland) have passed "first in man trials" successfully and are being evaluated within multicenter pivotal studies. In this article we will focus on specific aspects of the TA technique for AVI. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. DR5 as a reporter system to study auxin response in Populus.

    PubMed

    Chen, Yiru; Yordanov, Yordan S; Ma, Cathleen; Strauss, Steven; Busov, Victor B

    2013-03-01

    KEY MESSAGE : Auxin responsive promoter DR5 reporter system is functional in Populus to monitor auxin response in tissues including leaves, roots, and stems. We described the behavior of the DR5::GUS reporter system in stably transformed Populus plants. We found several similarities with Arabidopsis, including sensitivity to native and synthetic auxins, rapid induction after treatment in a variety of tissues, and maximal responses in root tissues. There were also several important differences from Arabidopsis, including slower time to maximum response and lower induction amplitude. Young leaves and stem sections below the apex showed much higher DR5 activity than did older leaves and stems undergoing secondary growth. DR5 activity was highest in cortex, suggesting high levels of auxin concentration and/or sensitivity in this tissue. Our study shows that the DR5 reporter system is a sensitive and facile system for monitoring auxin responses and distribution at cellular resolution in poplar.

  7. Polymerization shrinkage stresses in different restorative techniques for non-carious cervical lesions.

    PubMed

    de Oliveira Correia, Ayla Macyelle; Tribst, João Paulo Mendes; de Souza Matos, Felipe; Platt, Jeffrey A; Caneppele, Taciana Marco Ferraz; Borges, Alexandre Luiz Souto

    2018-06-20

    This study evaluated the effect of different restorative techniques for non-carious cervical lesions (NCCL) on polymerization shrinkage stress of resins using three-dimensional (3D) finite element analysis (FEA). 3D-models of a maxillary premolar with a NCCL restored with different filling techniques (bulk filling and incremental) were generated to be compared by nonlinear FEA. The bulk filling technique was used for groups B (NCCL restored with Filtek™ Bulk Fill) and C (Filtek™ Z350 XT). The incremental technique was subdivided according to mode of application: P (2 parallel increments of the Filtek™ Z350 XT), OI (2 oblique increments of the Filtek™ Z350 XT, with incisal first), OIV (2 oblique increments of the Filtek™ Z350 XT, with incisal first and increments with the same volume), OG (2 oblique increments of the Filtek™ Z350 XT, with gingival first) and OGV (2 oblique increments of the Filtek™ Z350 XT, with gingival first and increments with the same volume), resulting in 7 models. All materials were considered isotropic, elastic and linear. The results were expressed in maximum principal stress (MPS). The tension stress distribution was influenced by the restorative technique. The lowest stress concentration occurred in group B followed by OG, OGV, OI, OIV, P and C; the incisal interface was more affected than the gingival. The restoration of NCCLs with bulk fill composite resulted in lower shrinkage stress in the gingival and incisal areas, followed by incremental techniques with the initial increment placed on the gingival wall. The non-carious cervical lesions (NCCLs) restored with bulk fill composite have a more favorable biomechanical behavior. Copyright © 2018. Published by Elsevier Ltd.

  8. Perturbation theory for fractional Brownian motion in presence of absorbing boundaries.

    PubMed

    Wiese, Kay Jörg; Majumdar, Satya N; Rosso, Alberto

    2011-06-01

    Fractional Brownian motion is a Gaussian process x(t) with zero mean and two-time correlations (x(t(1))x(t(2)))=D(t(1)(2H)+t(2)(2H)-|t(1)-t(2)|(2H)), where H, with 0x(t) is a Brownian motion, while for H≠1/2, x(t) is a non-Markovian process. Here we study x(t) in presence of an absorbing boundary at the origin and focus on the probability density P(+)(x,t) for the process to arrive at x at time t, starting near the origin at time 0, given that it has never crossed the origin. It has a scaling form P(+)(x,t)~t(-H)R(+)(x/t(H)). Our objective is to compute the scaling function R(+)(y), which up to now was only known for the Markov case H=1/2. We develop a systematic perturbation theory around this limit, setting H=1/2+ε, to calculate the scaling function R(+)(y) to first order in ε. We find that R(+)(y) behaves as R(+)(y)~y(ϕ) as y→0 (near the absorbing boundary), while R(+)(y)~y(γ)exp(-y(2)/2) as y→∞, with ϕ=1-4ε+O(ε(2)) and γ=1-2ε+O(ε(2)). Our ε-expansion result confirms the scaling relation ϕ=(1-H)/H proposed in Zoia, Rosso, and Majumdar [Phys. Rev. Lett. 102, 120602 (2009)]. We verify our findings via numerical simulations for H=2/3. The tools developed here are versatile, powerful, and adaptable to different situations.

  9. Reference Architecture for MNE 5 Technical System

    DTIC Science & Technology

    2007-05-30

    of being available in most experiments. Core Services A core set of applications whi directories, web portal and collaboration applications etc. A...classifications Messages (xml, JMS, content level…) Meta data filtering, who can initiate services Web browsing Collaboration & messaging Border...Exchange Ref Architecture for MNE5 Tech System.doc 9 of 21 audit logging Person and machine Data lev objects, web services, messages rification el

  10. A comparison between the shear bond strength of brackets bonded to glazed and deglazed porcelain surfaces with resin-reinforced glass-ionomer cement and a bis-GMA resin adhesive.

    PubMed

    Lifshitz, Abraham B; Cárdenas, Marianela

    2006-01-01

    This study compared the shear bond strength of a light-cure resin-reinforced glass-ionomer cement with a bis-GMA light-cure resin system in the bonding of stainless steel brackets to glazed and deglazed porcelain surfaces. Porcelain surfaces were divided into 4 groups: group 1, deglazed porcelain surfaces with Transbond XT, group 2, glazed porcelain surfaces with Transbond XT; group 3, deglazed porcelain surfaces with Fuji Ortho LC; and group 4, porcelain surfaces with Fuji Ortho LC. Microetching with 50-microm aluminum oxide for 2 seconds at a distance of 5 mm deglazed the porcelain surfaces in groups 1 and 3. All brackets were bonded to the porcelain surfaces using the same procedure and light-cured for 40 seconds with a visible light. All samples were thermocycled between 5 degrees C and 55 degrees C for 300 cycles before testing for shear bond strength with a universal testing machine. The analysis of variance showed no significant difference (P < .05) among the 4 groups; ie, group 1, 10.12 MPa; group 2, 7.00 MPa; group 3, 6.78 MPa; and group 4, 11.15 MPa. The F test also failed to demonstrate any statistical difference among the groups. Conditioning the porcelain surfaces with 37% phosphoric acid immediately followed by a nonhydrolyzed silane coupling agent resulted in clinically adequate bond strength when using either a composite resin or a resin-reinforced glass-ionomer cement. Microetching of these porcelain surfaces apparently offers no bonding advantage.

  11. Proton spectral editing in the inhomogeneous radiofrequency field of a surface coil using modified stimulated echoes.

    PubMed

    Lahrech, H; Briguet, A

    1990-11-01

    It is shown that the modified stimulated echo sequence, [theta](+/- x +/- y)-t1-[theta](+ x)-t2/2-[2 theta](+ x)-t2/2- [theta](+ x)-t1-Acq(+/- x +/- y), denoted as MSTE[2 theta]x according to the exciter phase of the 2 theta pulse, is able to perform proton spectral editing without difference spectra. On the other hand, this sequence appears to be suitable for spatial localization. Sensitivity and spatial selectivity of MSTE and conventional stimulated echo sequence (STE) are briefly compared. MSTE is applied to editing lactate in the rat brain using the locally restricted excitation of a surface coil.

  12. Enhanced Traffic Management System (ETMS) : functional description, version 5.0

    DOT National Transportation Integrated Search

    1995-06-30

    This document is a functional description of Version 5.0 of the Enhanced Traffic : Management System (ETMS). The ETMSis an automation system for supporting the : strategic management of air traffic. The ETMS is being developed and maintained in : con...

  13. Portable Life Support System 2.5 Fan Design and Development

    NASA Technical Reports Server (NTRS)

    Quinn, Gregory; Carra, Michael; Converse, David; Chullen, Cinda

    2016-01-01

    NASA is building a high-fidelity prototype of an advanced Portable Life Support System (PLSS) as part of the Advanced Exploration Systems Program. This new PLSS, designated as PLSS 2.5, will advance component technologies and systems knowledge to inform a future flight program. The oxygen ventilation loop of its predecessor, PLSS 2.0, was driven by a centrifugal fan developed using specifications from the Constellation Program. PLSS technology and system parameters have matured to the point where the existing fan will not perform adequately for the new prototype. In addition, areas of potential improvement were identified with the PLSS 2.0 fan that could be addressed in a new design. As a result, a new fan was designed and tested for the PLSS 2.5. The PLSS 2.5 fan is a derivative of the one used in PLSS 2.0, and it uses the same nonmetallic, canned motor, with a larger volute and impeller to meet the higher pressure drop requirements of the PLSS 2.5 ventilation loop. The larger impeller allows it to operate at rotational speeds that are matched to rolling element bearings, and which create reasonably low impeller tip speeds consistent with prior, oxygen-rated fans. Development of the fan also considered a shrouded impeller design that could allow larger clearances for greater oxygen safety, assembly tolerances and particle ingestion. This paper discusses the design, manufacturing and performance testing of the new fans.

  14. Chlorhexidine stabilizes the adhesive interface: a 2 year in vitro study

    PubMed Central

    Breschi, Lorenzo; Mazzoni, Annalisa; Nato, Fernando; Carrilho, Marcela; Visintini, Erika; Tjäderhane, Leo; Ruggeri, Alessandra; Tay, Franklin R; De Stefano Dorigo, Elettra; Pashley, David H

    2013-01-01

    Objectives This study evaluated the role of endogenous dentin MMPs in auto-degradation of collagen fibrils within adhesive-bonded interfaces. The null hypotheses tested were that adhesive blends or chlorhexidine digluconate (CHX) application does not modify dentin MMPs activity and that CHX used as therapeutic primer does not improve the stability of adhesive interfaces over time. Methods Zymograms of protein extracts from human dentin powder incubated with Adper Scotchbond 1XT (SB1XT) on untreated or 0.2–2% CHX treated dentin were obtained to assay dentin MMPs activity. Microtensile bond strength and interfacial nanoleakage expression of SB1XT bonded interfaces (with or without CHX pre-treatment for 30s on the etched surface) were analyzed immediately and after 2 yr of storage in artificial saliva at 37°C. Results Zymograms showed that application of SB1XT to human dentin powder increases MMP-2 activity, while CHX pre-treatment inhibited all dentin gelatinolytic activity, irrespective from the tested concentration. CHX significantly lowered the loss of bond strength and nanoleakage seen in acid-etched resin-bonded dentin artificially aged for 2 yr. Significance The study demonstrates the active role of SB1XT in dentin MMP-2 activation and the efficacy of CHX inhibition of MMPs even if used at low concentration (0.2%). PMID:20045177

  15. Evaluation of shear bond strength of orthodontic brackets bonded with nano-filled composites.

    PubMed

    Chalipa, Javad; Akhondi, Mohammad Sadegh Ahmad; Arab, Sepideh; Kharrazifard, Mohammad Javad; Ahmadyar, Maryam

    2013-09-01

    The purpose of this study was to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with two types of nano-composites in comparison to a conventional orthodontic composite. Sixty extracted human first premolars were randomly divided into 3 groups each containing 20 teeth. In group I, a conventional orthodontic composite (Transbond XT) was used to bond the brackets, while two nano-composites (Filtek TM Supreme XT and AELITE Aesthetic Enamel) were used in groups II and III respectively. The teeth were stored in distilled water at 37°C for 24 hours, thermocycled in distilled water and debonded with a universal testing machine at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was also evaluated using a stereomicroscope. AELITE Aesthetic Enamel nano-composite revealed a SBS value of 8.44±2.09 MPa, which was higher than Transbond XT (6.91±2.13) and Filtek TM Supreme XT (6.04±2.01). Statistical analysis revealed a significant difference between groups II and III (P < 0.05). No significant difference was found between groups I and III, and between groups I and II (P > 0.05). Evaluation of ARI showed that Transbond XT left fewer adhesive remains on teeth after debonding. Results of this study indicate that the aforementioned nano-composites can be successfully used for bonding orthodontic brackets.

  16. HOXA5 plays tissue-specific roles in the developing respiratory system.

    PubMed

    Landry-Truchon, Kim; Houde, Nicolas; Boucherat, Olivier; Joncas, France-Hélène; Dasen, Jeremy S; Philippidou, Polyxeni; Mansfield, Jennifer H; Jeannotte, Lucie

    2017-10-01

    Hoxa5 is essential for development of several organs and tissues. In the respiratory system, loss of Hoxa5 function causes neonatal death due to respiratory distress. Expression of HOXA5 protein in mesenchyme of the respiratory tract and in phrenic motor neurons of the central nervous system led us to address the individual contribution of these Hoxa5 expression domains using a conditional gene targeting approach. Hoxa5 does not play a cell-autonomous role in lung epithelium, consistent with lack of HOXA5 expression in this cell layer. In contrast, ablation of Hoxa5 in mesenchyme perturbed trachea development, lung epithelial cell differentiation and lung growth. Further, deletion of Hoxa5 in motor neurons resulted in abnormal diaphragm innervation and musculature, and lung hypoplasia. It also reproduced the neonatal lethality observed in null mutants, indicating that the defective diaphragm is the main cause of impaired survival at birth. Thus, Hoxa5 possesses tissue-specific functions that differentially contribute to the morphogenesis of the respiratory tract. © 2017. Published by The Company of Biologists Ltd.

  17. Role of TiF4 in Microleakage of Silorane and Methacrylate-based Composite Resins in Class V Cavities.

    PubMed

    Koohpeima, Fatemeh; Sharafeddin, Farahnaz; Jowkar, Zahra; Ahmadzadeh, Samaneh; Mokhtari, Mohammad Javad; Azarian, Babak

    2016-03-01

    This study investigated the effect of TiF4 solution pretreat-ment on microleakage of silorane and nanofilled methacrylate-based composites in class V cavities. Forty-eight intact premolar teeth were randomly allocated to four groups of 12 teeth. Restorative techniques after standard class V tooth preparations were as follows: Group 1, Filtek P90 composite; group 2, Filtek Z350 XT; group 3, TiF4 solution pretreatment and Filtek P90 composite; group 4, TiF4 solution pretreatment and Filtek Z350 XT. After storing the specimens in distilled water at 37°C for 24 hours and followed by immersion of the specimens in a 0.5% basic-fuchsin solution for 24 hours, they were sectioned buccolingually to obtain four surfaces for each specimen for analysis of microleakage using a stereomicroscope. Data analysis was performed using Kruskal-Wallis test to compare the four groups and the Mann-Whitney test for paired comparisons with Statistical Package for the Social Sciences (SPSS) version 17 software. At the enamel margins, microleakage score of the Filtek Z350 XT group was lower than those of the Filtek P90 with and without the application of the TiF4 (p = 0.009 and p = 0.031 respectively). At the dentin margins, groups 3 and 4 (TiF4+Filtek P90 and TiF4+Filtek z350 XT respectively) showed significantly lower microleakage than group 1 (Filtek P90). However, there was no significant difference between other groups (p > 0.05). At the enamel margins, microleakage score of the silorane-based composite was more than that of the nanofilled composite. No significant differences were observed between the other groups. At the dentin margins, for the silorane-based composite restorations, TiF4 solution pretreatment resulted in significantly lower microleakage. However, the similar result was not observed for Filtek Z350 XT. Also, no significant difference was observed between microleakage scores of Filtek P90 and Filtek Z350 XT with or without TiF4 pretreatment. In spite of better mechanical

  18. Sample-to-sample fluctuations of power spectrum of a random motion in a periodic Sinai model.

    PubMed

    Dean, David S; Iorio, Antonio; Marinari, Enzo; Oshanin, Gleb

    2016-09-01

    The Sinai model of a tracer diffusing in a quenched Brownian potential is a much-studied problem exhibiting a logarithmically slow anomalous diffusion due to the growth of energy barriers with the system size. However, if the potential is random but periodic, the regime of anomalous diffusion crosses over to one of normal diffusion once a tracer has diffused over a few periods of the system. Here we consider a system in which the potential is given by a Brownian bridge on a finite interval (0,L) and then periodically repeated over the whole real line and study the power spectrum S(f) of the diffusive process x(t) in such a potential. We show that for most of realizations of x(t) in a given realization of the potential, the low-frequency behavior is S(f)∼A/f^{2}, i.e., the same as for standard Brownian motion, and the amplitude A is a disorder-dependent random variable with a finite support. Focusing on the statistical properties of this random variable, we determine the moments of A of arbitrary, negative, or positive order k and demonstrate that they exhibit a multifractal dependence on k and a rather unusual dependence on the temperature and on the periodicity L, which are supported by atypical realizations of the periodic disorder. We finally show that the distribution of A has a log-normal left tail and exhibits an essential singularity close to the right edge of the support, which is related to the Lifshitz singularity. Our findings are based both on analytic results and on extensive numerical simulations of the process x(t).

  19. On the role of adhesion in single-file dynamics

    NASA Astrophysics Data System (ADS)

    Fouad, Ahmed M.; Noel, John A.

    2017-08-01

    For a one-dimensional interacting system of Brownian particles with hard-core interactions (a single-file model), we study the effect of adhesion on both the collective diffusion (diffusion of the entire system with respect to its center of mass) and the tracer diffusion (diffusion of the individual tagged particles). For the case with no adhesion, all properties of these particle systems that are independent of particle labeling (symmetric in all particle coordinates and velocities) are identical to those of non-interacting particles (Lebowitz and Percus, 1967). We clarify this last fact twice. First, we derive our analytical predictions that show that the probability-density functions of single-file (ρsf) and ordinary (ρord) diffusion are identical, ρsf =ρord, predicting a nonanomalous (ordinary) behavior for the collective single-file diffusion, where the average second moment with respect to the center of mass, < x(t) 2 > , is calculated from ρ for both diffusion processes. Second, for single-file diffusion, we show, both analytically and through large-scale simulations, that < x(t) 2 > grows linearly with time, confirming the nonanomalous behavior. This nonanomalous collective behavior comes in contrast to the well-known anomalous sub-diffusion behavior of the individual tagged particles (Harris, 1965). We introduce adhesion to single-file dynamics as a second inter-particle interaction rule and, interestingly, we show that adding adhesion does reduce the magnitudes of both < x(t) 2 > and the mean square displacement per particle Δx2; but the diffusion behavior remains intact independent of adhesion in both cases. Moreover, we study the dependence of both the collective diffusion constant D and the tracer diffusion constant DT on the adhesion coefficient α.

  20. Climate change projections using the IPSL-CM5 Earth System Model: from CMIP3 to CMIP5

    NASA Astrophysics Data System (ADS)

    Dufresne, J.-L.; Foujols, M.-A.; Denvil, S.; Caubel, A.; Marti, O.; Aumont, O.; Balkanski, Y.; Bekki, S.; Bellenger, H.; Benshila, R.; Bony, S.; Bopp, L.; Braconnot, P.; Brockmann, P.; Cadule, P.; Cheruy, F.; Codron, F.; Cozic, A.; Cugnet, D.; de Noblet, N.; Duvel, J.-P.; Ethé, C.; Fairhead, L.; Fichefet, T.; Flavoni, S.; Friedlingstein, P.; Grandpeix, J.-Y.; Guez, L.; Guilyardi, E.; Hauglustaine, D.; Hourdin, F.; Idelkadi, A.; Ghattas, J.; Joussaume, S.; Kageyama, M.; Krinner, G.; Labetoulle, S.; Lahellec, A.; Lefebvre, M.-P.; Lefevre, F.; Levy, C.; Li, Z. X.; Lloyd, J.; Lott, F.; Madec, G.; Mancip, M.; Marchand, M.; Masson, S.; Meurdesoif, Y.; Mignot, J.; Musat, I.; Parouty, S.; Polcher, J.; Rio, C.; Schulz, M.; Swingedouw, D.; Szopa, S.; Talandier, C.; Terray, P.; Viovy, N.; Vuichard, N.

    2013-05-01

    We present the global general circulation model IPSL-CM5 developed to study the long-term response of the climate system to natural and anthropogenic forcings as part of the 5th Phase of the Coupled Model Intercomparison Project (CMIP5). This model includes an interactive carbon cycle, a representation of tropospheric and stratospheric chemistry, and a comprehensive representation of aerosols. As it represents the principal dynamical, physical, and bio-geochemical processes relevant to the climate system, it may be referred to as an Earth System Model. However, the IPSL-CM5 model may be used in a multitude of configurations associated with different boundary conditions and with a range of complexities in terms of processes and interactions. This paper presents an overview of the different model components and explains how they were coupled and used to simulate historical climate changes over the past 150 years and different scenarios of future climate change. A single version of the IPSL-CM5 model (IPSL-CM5A-LR) was used to provide climate projections associated with different socio-economic scenarios, including the different Representative Concentration Pathways considered by CMIP5 and several scenarios from the Special Report on Emission Scenarios considered by CMIP3. Results suggest that the magnitude of global warming projections primarily depends on the socio-economic scenario considered, that there is potential for an aggressive mitigation policy to limit global warming to about two degrees, and that the behavior of some components of the climate system such as the Arctic sea ice and the Atlantic Meridional Overturning Circulation may change drastically by the end of the twenty-first century in the case of a no climate policy scenario. Although the magnitude of regional temperature and precipitation changes depends fairly linearly on the magnitude of the projected global warming (and thus on the scenario considered), the geographical pattern of these changes

  1. Stellar Inertial Navigation Workstation

    NASA Technical Reports Server (NTRS)

    Johnson, W.; Johnson, B.; Swaminathan, N.

    1989-01-01

    Software and hardware assembled to support specific engineering activities. Stellar Inertial Navigation Workstation (SINW) is integrated computer workstation providing systems and engineering support functions for Space Shuttle guidance and navigation-system logistics, repair, and procurement activities. Consists of personal-computer hardware, packaged software, and custom software integrated together into user-friendly, menu-driven system. Designed to operate on IBM PC XT. Applied in business and industry to develop similar workstations.

  2. Testudinibacter aquarius gen. nov., sp. nov., a member of the family Pasteurellaceae isolated from the oral cavity of freshwater turtles.

    PubMed

    Hansen, Mie Johanne; Pennanen, Elin Anna Erica; Bojesen, Anders Miki; Christensen, Henrik; Bertelsen, Mads Frost

    2016-02-01

    A total of 13 Pasteurellaceae isolates from healthy freshwater turtles were characterized by genotypic and phenotypic tests. Phylogenetic analysis of partial 16S rRNA and rpoB gene sequences showed that the isolates investigated formed a monophyletic group. The closest related species based on 16S rRNA gene sequencing was Chelonobacter oris CCUG 55632T with 94.4 % similarity and the closest related species based on rpoB gene sequence comparison was [Pasteurella] testudinis CCUG 19802T with 91.5 % similarity. All the investigated isolates exhibited phenotypic characteristics of the family Pasteurellaceae. However, they could be separated from existing genera of the Pasteurellaceae by the following test results: indole, ornithine decarboxylase and Voges-Proskauer positive; and methyl red, urease and PNPG (α-glucosidase) negative. No X- or V-factor requirement was observed. A zone of β-haemolysis surrounded the colonies after 24 h of incubation on bovine blood agar at 37 °C. Acid was produced from l-arabinose, dulcitol, d-mannitol, sucrose and trehalose. Representative strain ELNT2xT had a fatty acid profile that was characteristic for members of the Pasteurellaceae. ELNT2xT expressed only one respiratory quinone, ubiquinone-8 (100 %). The DNA G+C content of strain ELNT2xT was 42.8 mol%. On the basis of both phylogenetic and phenotypic evidence, it is proposed that the strains should be classified as representatives of a novel species of a new genus, Testudinibacter aquarius gen. nov., sp. nov. The type strain of Testudinibacter aquarius is ELNT2xT ( = CCUG 65146T = DSM 28140T), which was isolated from the oral cavity of a captive eastern long-necked turtle (Chelodina longicollis) in Denmark in 2012.

  3. On diagrammatic technique for nonlinear dynamical systems

    NASA Astrophysics Data System (ADS)

    Semenyakin, Mykola

    2014-11-01

    In this paper, we investigate phase flows over ℂn and ℝn generated by vector fields V = ∑ Pi∂i where Pi are finite degree polynomials. With the convenient diagrammatic technique, we get expressions for evolution operators ev{V|t} : x(0) ↦ x(t) through the series in powers of x(0) and t, represented as sum over all trees of a particular type. Estimates are made for the radius of convergence in some particular cases. The phase flows behavior in the neighborhood of vector field fixed points are examined. Resonance cases are considered separately.

  4. Power System Electronics Accommodation for a Lithium Ion Battery on the Space Technology 5 (ST5) Mission

    NASA Technical Reports Server (NTRS)

    Castell, Karen; Day, John H. (Technical Monitor)

    2001-01-01

    ST5 mission requirements include validation of Lithium-ion battery in orbit. Accommodation in the power system for Li-ion battery can be reduced with smaller amp-hour size, highly matched cells when compared to the larger amp-hour size approach. Result can be lower system mass and increased reliability.

  5. The Device Centric Communication System for 5G Networks

    NASA Astrophysics Data System (ADS)

    Biswash, S. K.; Jayakody, D. N. K.

    2017-01-01

    The Fifth Generation Communication (5G) networks have several functional features such as: Massive Multiple Input and Multiple Output (MIMO), Device centric data and voice support, Smarter-device communications, etc. The objective for 5G networks is to gain the 1000x more throughput, 10x spectral efficiency, 100 x more energy efficiency than existing technologies. The 5G system will provide the balance between the Quality of Experience (QoE) and the Quality of Service (QoS), without compromising the user benefit. The data rate has been the key metric for wireless QoS; QoE deals with the delay and throughput. In order to realize a balance between the QoS and QoE, we propose a cellular Device centric communication methodology for the overlapping network coverage area in the 5G communication system. The multiple beacon signals mobile tower refers to an overlapping network area, and a user must be forwarded to the next location area. To resolve this issue, we suggest the user centric methodology (without Base Station interface) to handover the device in the next area, until the users finalize the communication. The proposed method will reduce the signalling cost and overheads for the communication.

  6. Revisiting Parallel Cyclic Reduction and Parallel Prefix-Based Algorithms for Block Tridiagonal System of Equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seal, Sudip K; Perumalla, Kalyan S; Hirshman, Steven Paul

    2013-01-01

    Simulations that require solutions of block tridiagonal systems of equations rely on fast parallel solvers for runtime efficiency. Leading parallel solvers that are highly effective for general systems of equations, dense or sparse, are limited in scalability when applied to block tridiagonal systems. This paper presents scalability results as well as detailed analyses of two parallel solvers that exploit the special structure of block tridiagonal matrices to deliver superior performance, often by orders of magnitude. A rigorous analysis of their relative parallel runtimes is shown to reveal the existence of a critical block size that separates the parameter space spannedmore » by the number of block rows, the block size and the processor count, into distinct regions that favor one or the other of the two solvers. Dependence of this critical block size on the above parameters as well as on machine-specific constants is established. These formal insights are supported by empirical results on up to 2,048 cores of a Cray XT4 system. To the best of our knowledge, this is the highest reported scalability for parallel block tridiagonal solvers to date.« less

  7. Bisphenol A release from orthodontic adhesives measured in vitro and in vivo with gas chromatography.

    PubMed

    Moreira, Marília Rodrigues; Matos, Leonardo Gontijo; de Souza, Israel Donizeti; Brigante, Tamires Amabile Valim; Queiroz, Maria Eugênia Costa; Romano, Fábio Lourenço; Nelson-Filho, Paulo; Matsumoto, Mírian Aiko Nakane

    2017-03-01

    The objectives of this study were to quantify in vitro the Bisphenol A (BPA) release from 5 orthodontic composites and to assess in vivo the BPA level in patients' saliva and urine after bracket bonding with an orthodontic adhesive system. For the in-vitro portion of this study, 5 orthodontic composites were evaluated: Eagle Spectrum (American Orthodontics, Sheboygan, Wis), Enlight (Ormco, Orange, Calif), Light Bond (Reliance Orthodontic Products, Itasca, Ill), Mono Lok II (Rocky Mountain Orthodontics, Denver, Colo), and Transbond XT (3M Unitek, Monrovia, Calif). Simulating intraoral conditions, the specimens were immersed in a water/ethanol solution, and the BPA (ng.g -1 ) liberation was measured after 30 minutes, 24 hours, 1 day, 1 week, and 1 month by the gas chromatography system coupled with mass spectrometry. Twenty patients indicated for fixed orthodontic treatment participated in the in-vivo study. Saliva samples were collected before bracket bonding and then 30 minutes, 24 hours, 1 day, 1 week, and 1 month after bonding the brackets. Urine samples were collected before bonding and then at 1 day, 1 week, and 1 month after bonding. The results were analyzed statistically using analysis of variance and Tukey posttest, with a significance level of 5%. All composites evaluated in vitro released small amounts of BPA. Enlight composite showed the greatest release, at 1 month. Regarding the in-vivo study, the mean BPA level in saliva increased significantly only at 30 minutes after bonding in comparison with measurements recorded before bonding. All orthodontic composites released BPA in vitro. Enlight and Light Bond had, respectively, the highest and lowest BPA releases in vitro. The in-vivo experiment showed that bracket bonding with the Transbond XT orthodontic adhesive system resulted in increased BPA levels in saliva and urine. The levels were significant but still lower than the reference dose for daily ingestion. Copyright © 2016

  8. Structural transition in Mg-doped LiMn 2O 4: a comparison with other M-doped Li-Mn spinels

    NASA Astrophysics Data System (ADS)

    Capsoni, Doretta; Bini, Marcella; Chiodelli, Gaetano; Massarotti, Vincenzo; Mozzati, Maria Cristina; Azzoni, Carlo B.

    2003-01-01

    The charge distribution in the Mg-doped lithium manganese spinel Li 1.02Mg xMn 1.98- xO 4 with 0.00< x≤0.20 is discussed and compared to those pertinent to other M-doped samples (M=Ni 2+, Co 3+, Cr 3+, Al 3+ and Ga 3+). EPR spectra, low temperature X-ray diffraction and conductivity data are related to the cooperative Jahn-Teller (J-T) transition occurring at about 280 K in the undoped sample. The sensitivity of the cationic sublattice in displaying electronic and magnetic changes after substitution is remarked. The inhibition of the J-T transition is related to the ratio r=|Mn 4+|/|Mn 3+| as deduced from the charge distribution model [Li 1- xt+Mg xt2+] tetr[Li y+ xt+Mg xo2+Mn 1-3 y-2 x3+Mn 1+2 y+ x4+] octa where x= xo+ xt. For y=0.02 and x=0.02, a value r=1.177 is obtained, very close to rlim=1.18, the limit value beyond which the transition is inhibited.

  9. Crosstalk-aware virtual network embedding over inter-datacenter optical networks with few-mode fibers

    NASA Astrophysics Data System (ADS)

    Huang, Haibin; Guo, Bingli; Li, Xin; Yin, Shan; Zhou, Yu; Huang, Shanguo

    2017-12-01

    Virtualization of datacenter (DC) infrastructures enables infrastructure providers (InPs) to provide novel services like virtual networks (VNs). Furthermore, optical networks have been employed to connect the metro-scale geographically distributed DCs. The synergistic virtualization of the DC infrastructures and optical networks enables the efficient VN service over inter-DC optical networks (inter-DCONs). While the capacity of the used standard single-mode fiber (SSMF) is limited by their nonlinear characteristics. Thus, mode-division multiplexing (MDM) technology based on few-mode fibers (FMFs) could be employed to increase the capacity of optical networks. Whereas, modal crosstalk (XT) introduced by optical fibers and components deployed in the MDM optical networks impacts the performance of VN embedding (VNE) over inter-DCONs with FMFs. In this paper, we propose a XT-aware VNE mechanism over inter-DCONs with FMFs. The impact of XT is considered throughout the VNE procedures. The simulation results show that the proposed XT-aware VNE can achieves better performances of blocking probability and spectrum utilization compared to conventional VNE mechanisms.

  10. Lectures in Complex Systems, (1992). Volume 5

    DTIC Science & Technology

    1993-05-01

    Lattice Gas Methods for Partial Differential Equations, 1989 V P. W. Anderson, K. Arrow, The Economy as an Evolving Complex System, D. Pines 1988 VI C...to Improve EEG Classification and to Explore GA Parametrization Cathleen Barczys, Laura Bloom, and Leslie Kay 569 Symbiosis in Society and Monopoly in...Appeal of Evolution 1.2 Elements of Genetic Algorithms 1.3 A Simple GA 1.4 Overview of Some Applications of Genetic Algorithms 1.5 A Brief Example

  11. Historical review of C-5A lift distribution control systems

    NASA Technical Reports Server (NTRS)

    Disney, T. E.; Eckholdt, D. C.

    1976-01-01

    Analytical and experimental development work on various load alleviation systems for the C-5A is reviewed to trace the development of the technical and hardware concepts to the present time. Variations in system objectives, means of implementation and effects on loads and airplane performance, stability and control are discussed.

  12. Update on the NASA GEOS-5 Aerosol Forecasting and Data Assimilation System

    NASA Technical Reports Server (NTRS)

    Colarco, Peter; da Silva, Arlindo; Aquila, Valentina; Bian, Huisheng; Buchard, Virginie; Castellanos, Patricia; Darmenov, Anton; Follette-Cook, Melanie; Govindaraju, Ravi; Keller, Christoph; hide

    2017-01-01

    GEOS-5 is the Goddard Earth Observing System model. GEOS-5 is maintained by the NASA Global Modeling and Assimilation Office. Core development is within GMAO,Goddard Atmospheric Chemistry and Dynamics Laboratory, and with external partners. Primary GEOS-5 functions: Earth system model for studying climate variability and change, provide research quality reanalyses for supporting NASA instrument teams and scientific community, provide near-real time forecasts of meteorology,aerosols, and other atmospheric constituents to support NASA airborne campaigns.

  13. Bandlimited computerized improvements in characterization of nonlinear systems with memory

    NASA Astrophysics Data System (ADS)

    Nuttall, Albert H.; Katz, Richard A.; Hughes, Derke R.; Koch, Robert M.

    2016-05-01

    The present article discusses some inroads in nonlinear signal processing made by the prime algorithm developer, Dr. Albert H. Nuttall and co-authors, a consortium of research scientists from the Naval Undersea Warfare Center Division, Newport, RI. The algorithm, called the Nuttall-Wiener-Volterra 'NWV' algorithm is named for its principal contributors [1], [2],[ 3] over many years of developmental research. The NWV algorithm significantly reduces the computational workload for characterizing nonlinear systems with memory. Following this formulation, two measurement waveforms on the system are required in order to characterize a specified nonlinear system under consideration: (1) an excitation input waveform, x(t) (the transmitted signal); and, (2) a response output waveform, z(t) (the received signal). Given these two measurement waveforms for a given propagation channel, a 'kernel' or 'channel response', h= [h0,h1,h2,h3] between the two measurement points, is computed via a least squares approach that optimizes modeled kernel values by performing a best fit between measured response z(t) and a modeled response y(t). New techniques significantly diminish the exponential growth of the number of computed kernel coefficients at second and third order in order to combat and reasonably alleviate the curse of dimensionality.

  14. 46 CFR 111.52-5 - Systems 1500 kilowatts or above.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Systems 1500 kilowatts or above. 111.52-5 Section 111.52-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC... procedure for utility or industrial applications. [CGD 94-108, 61 FR 28279, June 4, 1996, as amended by USCG...

  15. 46 CFR 111.52-5 - Systems 1500 kilowatts or above.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Systems 1500 kilowatts or above. 111.52-5 Section 111.52-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC... procedure for utility or industrial applications. [CGD 94-108, 61 FR 28279, June 4, 1996, as amended by USCG...

  16. 46 CFR 111.52-5 - Systems 1500 kilowatts or above.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Systems 1500 kilowatts or above. 111.52-5 Section 111.52-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC... procedure for utility or industrial applications. [CGD 94-108, 61 FR 28279, June 4, 1996, as amended by USCG...

  17. 46 CFR 111.52-5 - Systems 1500 kilowatts or above.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Systems 1500 kilowatts or above. 111.52-5 Section 111.52-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC... procedure for utility or industrial applications. [CGD 94-108, 61 FR 28279, June 4, 1996, as amended by USCG...

  18. 46 CFR 111.52-5 - Systems 1500 kilowatts or above.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Systems 1500 kilowatts or above. 111.52-5 Section 111.52-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC... procedure for utility or industrial applications. [CGD 94-108, 61 FR 28279, June 4, 1996, as amended by USCG...

  19. A 4-year clinical evaluation of direct composite build-ups for space closure after orthodontic treatment.

    PubMed

    Demirci, Mustafa; Tuncer, Safa; Öztaş, Evren; Tekçe, Neslihan; Uysal, Ömer

    2015-12-01

    To evaluate the medium-term clinical performance of direct composite build-ups for diastema closures and teeth recontouring using a nano and a nanohybrid composite in combination with three- or two-step etch-and-rinse adhesives following treatment with fixed orthodontic appliances. A total of 30 patients (mean age, 19.5 years) received 147 direct composite additions for teeth recontouring and diastema closures. A nano and a nanohybrid composite (Filtek Supreme XT and CeramX Duo) were bonded to tooth structure by using a three-step (Scotchbond Multipurpose) or a two-step (XP Bond) etch and rinse adhesive. Ten out of 147 composite build-ups (composite addition) constituted tooth recontouring cases, and the remaining 137 constituted diastema closure cases. The restorations were evaluated by two experienced, calibrated examiners according to modified Ryge criteria at the following time intervals: baseline, 1, 2, 3, and 4 years. The 4-year survival rates were 92.8 % for Filtek Supreme XT/Scotchbond Multi-Purpose Plus and 93 % for CeramX Duo/XP Bond. Only ten restorations failed (5 Filtek Supreme XT and 5 CeramX Duo). Statistical analysis revealed no significant differences between the two composite-adhesive combinations with respect to color match, marginal discoloration, wear/loss of anatomical form, caries formation, marginal adaptation, and surface texture on comparing the five time periods (baseline, 1, 2, 3, and 4 years) The 4-year survival rates in the present study were favorable. The restorations exhibited excellent scores with regard to color match, marginal adaptation, surface texture, marginal discoloration, wear/loss of anatomical form, and caries formation, after 4 years of clinical evaluation. Clinical relevance An alternative clinical approach for correcting discrepancies in tooth size and form, such as performing direct composite restorations following fixed orthodontic treatment, may be an excellent and minimally invasive treatment.

  20. [Effects of surface treatment and adhesive application on shear bond strength between zirconia and enamel].

    PubMed

    Li, Yinghui; Wu, Buling; Sun, Fengyang

    2013-03-01

    To evaluate the effects of sandblasting and different orthodontic adhesives on shear bond strength between zirconia and enamel. Zirconia ceramic samples were designed and manufactured for 40 extracted human maxillary first premolars with CAD/CAM system. The samples were randomized into 4 groups for surface treatment with sandblasting and non-treated with adhesives of 3M Transbond XT or Jingjin dental enamel bonding resin. After 24 h of bonded fixation, the shear bond strengths were measured by universal mechanical testing machine and analyzed with factorial variance analysis. The shear bond strength was significantly higher in sandblasting group than in untreated group (P<0.05) and comparable between the two groups with the adhesives of Transbond XT and dental enamel bonding resin (P>0.05). The shear bond strength between zirconia and enamel is sufficient after sandblasting regardless of the application of either adhesive.

  1. Measurements of Multi-star Systems LEO 5 and MKT 13

    NASA Astrophysics Data System (ADS)

    AlZaben, Faisal; Priest, Allen; Priest, Stephen; Qiu, Rex; Boyce, Grady; Boyce, Pat

    2016-04-01

    We report measurements of the position angles and separations of two multi-star systems observed during the fall of 2015. Image data was obtained using an online 17-inch iTelescope system in Nerpio, Spain. Image data was analyzed using Maxim DL Pro 6 and Mira Pro x64 software tools at the Army and Navy Academy in Carlsbad, California. Our measurements of the LEO 5 system are consistent with historical data, although inconclusive as to the nature of the system. Our measurements and the historical data for the MKT 13 system show a consistent linearity in the position angle and separation.

  2. 5 CFR 534.406 - Conversion to the SES pay system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Conversion to the SES pay system. 534.406... UNDER OTHER SYSTEMS Pay and Performance Awards Under the Senior Executive Service § 534.406 Conversion... senior executive's converted rate of basic pay. Conversion to a new SES rate of basic pay is not...

  3. Shear bond strength of different adhesives tested in accordance with DIN 13990-1/-2 and using various methods of enamel conditioning.

    PubMed

    Richter, C; Jost-Brinkmann, P-G

    2015-03-01

    The purpose of this work was to analyze the shear bond strength (SBS) of different adhesives for orthodontic brackets in accordance with DIN 13990-1/-2, also taking into consideration potential effects arising from different scenarios of enamel conditioning and specimen storage. A total of 390 experiments were performed, with groups of 10 specimens subjected to identical treatments. Three adhesives were tested: Transbond™ XT (3M Unitek, Monrovia, USA), Beauty Ortho Bond (Shofu, Kyoto, Japan), and Fuji Ortho LC (GC Europe, Leuven, Belgium). SBS was evaluated separately at the bracket-adhesive and adhesive-enamel interfaces, as well as the total (enamel-adhesive-bracket) interface. The brackets were metal brackets for upper right central incisors (Discovery® from Dentaurum, Ispringen, Germany). A universal testing machine (Zwick Z010, Ulm, Germany) was used for testing the SBS after 15 min, or after storage in distilled water at 37 °C for 24 h, or after 24 h followed by 500 thermocycles alternating between 5 and 55 °C. Transbond™ XT produced the highest levels of SBS. The least favorable performance was observed with Fuji Ortho LC after enamel conditioning with 10 % polyacrylic acid. Thermocycling did not have a significant influence. Transbond™ XT and Beauty Ortho Bond (but not Fuji Ortho LC) yielded levels of SBS adequate for clinical application (≥ 7 MPa).

  4. Access 5 - Step 1: Human Systems Integration Program Plan (HSIPP)

    NASA Technical Reports Server (NTRS)

    2005-01-01

    This report describes the Human System Interface (HSI) analysis, design and test activities that will be performed to support the development of requirements and design guidelines to facilitate the incorporation of High Altitude Long Endurance (HALE) Remotely Operated Aircraft (ROA) at or above FL400 in the National Airspace System (NAS). These activities are required to support the design and development of safe, effective and reliable ROA operator and ATC interfaces. This plan focuses on the activities to be completed for Step 1 of the ACCESS 5 program. Updates to this document will be made for each of the four ACCESS 5 program steps.

  5. Impact of Noise on a Dynamical System: Prediction and Uncertainties from a Swarm-Optimized Neural Network

    PubMed Central

    López-Caraballo, C. H.; Lazzús, J. A.; Salfate, I.; Rojas, P.; Rivera, M.; Palma-Chilla, L.

    2015-01-01

    An artificial neural network (ANN) based on particle swarm optimization (PSO) was developed for the time series prediction. The hybrid ANN+PSO algorithm was applied on Mackey-Glass chaotic time series in the short-term x(t + 6). The performance prediction was evaluated and compared with other studies available in the literature. Also, we presented properties of the dynamical system via the study of chaotic behaviour obtained from the predicted time series. Next, the hybrid ANN+PSO algorithm was complemented with a Gaussian stochastic procedure (called stochastic hybrid ANN+PSO) in order to obtain a new estimator of the predictions, which also allowed us to compute the uncertainties of predictions for noisy Mackey-Glass chaotic time series. Thus, we studied the impact of noise for several cases with a white noise level (σ N) from 0.01 to 0.1. PMID:26351449

  6. Impact of Noise on a Dynamical System: Prediction and Uncertainties from a Swarm-Optimized Neural Network.

    PubMed

    López-Caraballo, C H; Lazzús, J A; Salfate, I; Rojas, P; Rivera, M; Palma-Chilla, L

    2015-01-01

    An artificial neural network (ANN) based on particle swarm optimization (PSO) was developed for the time series prediction. The hybrid ANN+PSO algorithm was applied on Mackey-Glass chaotic time series in the short-term x(t + 6). The performance prediction was evaluated and compared with other studies available in the literature. Also, we presented properties of the dynamical system via the study of chaotic behaviour obtained from the predicted time series. Next, the hybrid ANN+PSO algorithm was complemented with a Gaussian stochastic procedure (called stochastic hybrid ANN+PSO) in order to obtain a new estimator of the predictions, which also allowed us to compute the uncertainties of predictions for noisy Mackey-Glass chaotic time series. Thus, we studied the impact of noise for several cases with a white noise level (σ(N)) from 0.01 to 0.1.

  7. ERDC MSRC (Major Shared Resource Center) Resource. Spring 2008

    DTIC Science & Technology

    2008-01-01

    obtained from ADCIRC results. The alpha test was performed on the Cray XT3 machine (Sapphire) at ERDC and the IBM P575+ system ( Babbage ) at the...2008 20 Scotty Swillie (center) and Charles Ray (far right) were part of the team that constructed the DoD HPCMP booth for the Conference (From

  8. Association of a common interferon regulatory factor 5 (IRF5) variant with increased risk of systemic lupus erythematosus (SLE).

    PubMed

    Demirci, F Y K; Manzi, S; Ramsey-Goldman, R; Minster, R L; Kenney, M; Shaw, P S; Dunlop-Thomas, C M; Kao, A H; Rhew, E; Bontempo, F; Kammerer, C; Kamboh, M I

    2007-05-01

    Interferon regulatory factor 5 (IRF5) belongs to a family of transcription factors that control the transactivation of type I interferon system-related genes, as well as the expression of several other genes involved in immune response, cell signalling, cell cycle control and apoptosis. Two recent studies reported a significant association between the IRF5/rs2004640 T allele and systemic lupus erythematosus (SLE). The purpose of this study was to determine whether the reported rs2004640 T allele association could be replicated in our independent SLE case-control sample. We genotyped DNA samples from 370 white SLE-affected female subjects and 462 white healthy female controls using the TaqMan Assay-on-Demand for rs2004640, and performed a case-control genetic association analysis. Frequency of the rs2004640 T allele was significantly higher in cases than in controls (56.5% vs. 50%; P= 0.008). The odds ratio for T allele carriers was 1.68 (95% CI: 1.20 - 2.34; P= 0.003). Our results in an independent case-control sample confirm the robust association of the IRF5/rs2004640 T allele with SLE risk, and further support the relevance of the type I interferon system in the pathogenesis of SLE and autoimmunity.

  9. Evaluation of Shear Bond Strength of Orthodontic Brackets Bonded with Nano-Filled Composites

    PubMed Central

    Chalipa, Javad; Akhondi, Mohammad Sadegh Ahmad; Arab, Sepideh; Kharrazifard, Mohammad Javad; Ahmadyar, Maryam

    2013-01-01

    Objectives: The purpose of this study was to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with two types of nano-composites in comparison to a conventional orthodontic composite. Materials and Methods: Sixty extracted human first premolars were randomly divided into 3 groups each containing 20 teeth. In group I, a conventional orthodontic composite (Transbond XT) was used to bond the brackets, while two nano-composites (Filtek TM Supreme XT and AELITE Aesthetic Enamel) were used in groups II and III respectively. The teeth were stored in distilled water at 37°C for 24 hours, thermocycled in distilled water and debonded with a universal testing machine at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was also evaluated using a stereomicroscope. Results: AELITE Aesthetic Enamel nano-composite revealed a SBS value of 8.44±2.09 MPa, which was higher than Transbond XT (6.91±2.13) and Filtek TM Supreme XT (6.04±2.01). Statistical analysis revealed a significant difference between groups II and III (P < 0.05). No significant difference was found between groups I and III, and between groups I and II (P > 0.05). Evaluation of ARI showed that Transbond XT left fewer adhesive remains on teeth after debonding. Conclusion: Results of this study indicate that the aforementioned nano-composites can be successfully used for bonding orthodontic brackets. PMID:24910655

  10. Comparison of shear bond strengths of conventional orthodontic composite and nano-ceramic restorative composite: an in vitro study.

    PubMed

    Nagar, Namit; Vaz, Anna C

    2013-01-01

    To compare the shear bond strength of a nano-ceramic restorative composite Ceram-X Mono(TM♦), a restorative resin with the traditional orthodontic composite Transbond XT(TM†) and to evaluate the site of bond failure using Adhesive Remnant Index. Sixty extracted human premolars were divided into two groups of 30 each. Stainless steel brackets were bonded using Transbond XT(TM†) (Group I) and Ceram-X Mono(TM♦) (Group II) according to manufacturer's protocol. Shear bond strength was measured on Universal testing machine at crosshead speed of 1 mm/minute. Adhesive Remnant Index scores were assigned to debonded brackets of each group. Data was analyzed using unpaired 't' test and Chi square test. The mean shear bond strength of Group I (Transbond XT(TM†)) was 12.89 MPa ± 2.19 and that of Group II (Ceram-X Mono(TM)) was 7.29 MPa ± 1.76. Unpaired 't' test revealed statistically significant differences amongst the shear bond strength of the samples measured. Chi-square test revealed statistically insignificant differences amongst the ARI scores of the samples measured. Ceram-X Mono(TM♦) had a lesser mean shear bond strength when compared to Transbond XT(TM†) which was statistically significant difference. However, the mean shear bond of Ceram X Mono was within the clinically acceptable range for bonding. Ceram-X Mono(TM†) and Transbond XT(TM†) showed cohesive fracture of adhesive in 72.6% and 66.6% of the specimens, respectively.

  11. 47 CFR 5.64 - Special provisions for satellite systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Section 5.64 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EXPERIMENTAL RADIO SERVICE... experimental satellite facilities may begin prior to Commission grant of an authorization. Such construction is..., applicants for an experimental authorization involving a satellite system must submit a description of the...

  12. 5 CFR 930.205 - Administrative law judge pay system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Administrative law judge pay system. 930.205 Section 930.205 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) PROGRAMS FOR SPECIFIC POSITIONS AND EXAMINATIONS (MISCELLANEOUS) Administrative Law...

  13. 5 CFR 930.205 - Administrative law judge pay system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 2 2014-01-01 2014-01-01 false Administrative law judge pay system. 930.205 Section 930.205 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) PROGRAMS FOR SPECIFIC POSITIONS AND EXAMINATIONS (MISCELLANEOUS) Administrative Law...

  14. 5 CFR 930.205 - Administrative law judge pay system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Administrative law judge pay system. 930.205 Section 930.205 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) PROGRAMS FOR SPECIFIC POSITIONS AND EXAMINATIONS (MISCELLANEOUS) Administrative Law...

  15. 5 CFR 930.205 - Administrative law judge pay system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 2 2013-01-01 2013-01-01 false Administrative law judge pay system. 930.205 Section 930.205 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) PROGRAMS FOR SPECIFIC POSITIONS AND EXAMINATIONS (MISCELLANEOUS) Administrative Law...

  16. 5 CFR 930.205 - Administrative law judge pay system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 2 2012-01-01 2012-01-01 false Administrative law judge pay system. 930.205 Section 930.205 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) PROGRAMS FOR SPECIFIC POSITIONS AND EXAMINATIONS (MISCELLANEOUS) Administrative Law...

  17. Accuracy Progressive Calculation of Lagrangian Trajectories from Gridded Velocity Field

    DTIC Science & Technology

    2014-01-01

    traced (Vries and Doos 2001). The two types of velocity are convertible. Routine ocean data 36 assimilation systems (Galanis et al. 2006; Lozano et...1b) 54 The position of each fluid particle, R(t) = [x(t), y(t), z(t)], is specified in the Lagrangian system . 55 The connection...coordinate 233 system at the southwest corner (Fig. 6). The x*- and y*- axes point eastward and northward, 234 respectively. Here, the superscript

  18. Is EQ-5D-5L Better Than EQ-5D-3L? A Head-to-Head Comparison of Descriptive Systems and Value Sets from Seven Countries.

    PubMed

    Janssen, Mathieu F; Bonsel, Gouke J; Luo, Nan

    2018-06-01

    This study describes the first empirical head-to-head comparison of EQ-5D-3L (3L) and EQ-5D-5L (5L) value sets for multiple countries. A large multinational dataset, including 3L and 5L data for eight patient groups and a student cohort, was used to compare 3L versus 5L value sets for Canada, China, England/UK (5L/3L, respectively), Japan, The Netherlands, South Korea and Spain. We used distributional analyses and two methods exploring discriminatory power: relative efficiency as assessed by the F statistic, and an area under the curve for the receiver-operating characteristics approach. Differences in outcomes were explored by separating descriptive system effects from valuation effects, and by exploring distributional location effects. In terms of distributional evenness, efficiency of scale use and the face validity of the resulting distributions, 5L was superior, leading to an increase in sensitivity and precision in health status measurement. When compared with 5L, 3L systematically overestimated health problems and consequently underestimated utilities. This led to bias, i.e. over- or underestimations of discriminatory power. We conclude that 5L provides more precise measurement at individual and group levels, both in terms of descriptive system data and utilities. The increased sensitivity and precision of 5L is likely to be generalisable to longitudinal studies, such as in intervention designs. Hence, we recommend the use of the 5L across applications, including economic evaluation, clinical and public health studies. The evaluative framework proved to be useful in assessing preference-based instruments and might be useful for future work in the development of descriptive systems or health classifications.

  19. Orbits and masses in the young triple system TWA 5

    NASA Astrophysics Data System (ADS)

    Köhler, R.; Ratzka, T.; Petr-Gotzens, M. G.; Correia, S.

    2013-10-01

    Aims: We aim to improve the orbital elements and determine the individual masses of the components in the triple system TWA 5. Methods: Five new relative astrometric positions in the H band were recorded with the adaptive optics system at the Very Large Telescope (VLT). We combine them with data from the literature and a measurement in the Ks band. We derive an improved fit for the orbit of TWA 5Aa-b around each other. Furthermore, we use the third component, TWA 5B, as an astrometric reference to determine the motion of Aa and Ab around their center of mass and compute their mass ratio. Results: We find an orbital period of 6.03 ± 0.01 years and a semi-major axis of 63.7 ± 0.2 mas (3.2 ± 0.1 AU). With the trigonometric distance of 50.1 ± 1.8 pc, this yields a system mass of 0.9 ± 0.1 M⊙, where the error is dominated by the error of the distance. The dynamical mass agrees with the system mass predicted by a number of theoretical models if we assume that TWA5 is at the young end of the age range of the TW Hydrae association. We find a mass ratio of MAb/MAa = 1.3-0.4+0.6 , where the less luminous component Ab is more massive. This result is likely to be a consequence of the large uncertainties due to the limited orbital coverage of the observations. Based on observations made with ESO Telescopes at the La Silla Paranal Observatory under programme ID 079.C-0103, 081.C-0393, 386.C-0205, 087.C-0209, 088.C-0046, 089.C-0167, and 090.C-0184.

  20. Performance evaluation of the Abbott CELL-DYN Emerald for use as a bench-top analyzer in a research setting.

    PubMed

    Khoo, T-L; Xiros, N; Guan, F; Orellana, D; Holst, J; Joshua, D E; Rasko, J E J

    2013-08-01

    The CELL-DYN Emerald is a compact bench-top hematology analyzer that can be used for a three-part white cell differential analysis. To determine its utility for analysis of human and mouse samples, we evaluated this machine against the larger CELL-DYN Sapphire and Sysmex XT2000iV hematology analyzers. 120 human (normal and abnormal) and 30 mouse (normal and abnormal) samples were analyzed on both the CELL-DYN Emerald and CELL-DYN Sapphire or Sysmex XT2000iV analyzers. For mouse samples, the CELL-DYN Emerald analyzer required manual recalibration based on the histogram populations. Analysis of the CELL-DYN Emerald showed excellent precision, within accepted ranges (white cell count CV% = 2.09%; hemoglobin CV% = 1.68%; platelets CV% = 4.13%). Linearity was excellent (R² ≥ 0.99), carryover was minimal (<1%), and overall interinstrument agreement was acceptable for both human and mouse samples. Comparison between the CELL-DYN Emerald and Sapphire analyzers for human samples or Sysmex XT2000iV analyzer for mouse samples showed excellent correlation for all parameters. The CELL-DYN Emerald was generally comparable to the larger reference analyzer for both human and mouse samples. It would be suitable for use in satellite research laboratories or as a backup system in larger laboratories. © 2012 John Wiley & Sons Ltd.

  1. One-year multicentre outcomes of transapical aortic valve implantation using the SAPIEN XT™ valve: the PREVAIL transapical study.

    PubMed

    Walther, Thomas; Thielmann, Matthias; Kempfert, Joerg; Schroefel, Holger; Wimmer-Greinecker, Gerhard; Treede, Hendrik; Wahlers, Thorsten; Wendler, Olaf

    2013-05-01

    The study aimed to evaluate 1-year outcomes of the multicentre PREVAIL transapical (TA) study of TA-aortic valve implantation (AVI) in high-risk patients. From September 2009 to August 2010, a total of 150 patients, aged 81.6 ± 5.8 years, 40.7% female, were included at 12 European TA-AVI experienced sites. Patients received 23 (n = 36), 26 (n = 57) and 29 mm (n = 57) second-generation SAPIEN XT™ (Edwards Lifesciences, Irvine, CA, USA) valves. The mean logistic EuroSCORE was 24.3 ± 7.0, and mean Society Thoracic Surgeons score was 7.5 ± 4.4%. Survival was 91.3% at 30 days and 77.9% at 1 year. Subgroup analysis revealed survivals of 91.7/88.9, 86.0/70.2, 96.55/91.2% for patients receiving 23-, 26- and 29-mm valves at 30 days and at 1 year, respectively. Transthoracic echocardiography revealed preserved left ventricular ejection fraction and low gradients. Aortic incompetence was none in 41/48, trace 30/36, mild 22/12 and moderate in 7/4% at discharge and 1 year. Walking distance increased from 221 (postimplant) to 284 m (at 1 year, P = 0.0004). Three patients required reoperation due to increasing aortic incompetence during follow-up. Causes of mortality at 1 year were cardiac (n = 7), stroke (n = 1) and others (n = 5). The European PREVAIL multicentre trial demonstrates good functionality and good outcomes for TA-AVI using the second-generation SAPIEN XT prosthesis and the ASCENDRA-II delivery system. The 29-mm SAPIEN XT valve was successfully introduced and showed excellent results.

  2. Effect of different surface treatments on the shear bond strength of nanofilled composite repairs

    PubMed Central

    Ahmadizenouz, Ghazaleh; Esmaeili, Behnaz; Taghvaei, Arnica; Jamali, Zahra; Jafari, Toloo; Amiri Daneshvar, Farshid; Khafri, Soraya

    2016-01-01

    Background. Repairing aged composite resin is a challenging process. Many surface treatment options have been proposed to this end. This study evaluated the effect of different surface treatments on the shear bond strength (SBS) of nano-filled composite resin repairs. Methods. Seventy-five cylindrical specimens of a Filtek Z350XT composite resin were fabricated and stored in 37°C distilled water for 24 hours. After thermocycling, the specimens were divided into 5 groups according to the following surface treatments: no treatment (group 1); air abrasion with 50-μm aluminum oxide particles (group 2); irradiation with Er:YAG laser beams (group 3); roughening with coarse-grit diamond bur + 35% phosphoric acid (group 4); and etching with 9% hydrofluoric acid for 120 s (group 5). Another group of Filtek Z350XT composite resin samples (4×6 mm) was fabricated for the measurement of cohesive strength (group 6). A silane coupling agent and an adhesive system were applied after each surface treatment. The specimens were restored with the same composite resin and thermocycled again. A shearing force was applied to the interface in a universal testing machine. Data were analyzed using one-way ANOVA and post hoc Tukey tests (P < 0.05). Results. One-way ANOVA indicated significant differences between the groups (P < 0.05). SBS of controls was significantly lower than the other groups; differences between groups 2, 3, 4, 5 and 6 were not significant. Surface treatment with diamond bur + 35% phosphoric acid resulted in the highest bond strength. Conclusion. All the surface treatments used in this study improved the shear bond strength of nanofilled composite resin used. PMID:27092209

  3. History of Canaveral District: 1950 - 1971

    DTIC Science & Technology

    1971-07-01

    world, the Canaveral sites had from the beginning required special precautions to alienate corrosion of exposed items. Special finishes were required...SHA’d rtr,. 111 E.xt 240 PAGE 5 UlI!IIIISTRATIVE Sl/PP(I!T NASA r-- __ .... J___ -. OfF I CZ Ufo ’ ,W,.:m. ’:;ERVI C:.s J. H. DAVl.:l Rrn 109

  4. Entropy-driven loss of gas-phase Group 5 species from GOLD/3-5 compound semiconductor systems

    NASA Astrophysics Data System (ADS)

    Pugh, J. H.; Williams, R. S.

    1986-02-01

    Temperature dependent chemical interactions between Au and nine 3-5 compound semiconductors (3=A1, Ga, In and V=P, As, Sb) have been calculated using bulk thermodynamic properties. Enthalpic considerations alone are insufficient to predict metal/compound-semiconductor reactivities. The entropy of vaporization of the group 5 elements is shown to be an extremely important driving force for chemical reactions involving the 3-5's, since it enables several endothermic reactions to occur spontaneously under certain temperature and pressure conditions. Plots of either Gibb's free energies of reaction or equilibrium vapor pressure of the group 5 element versus temperature are used to predict critical reaction temperatures for each of the systems studied. These plots agree extremely well with previous experimental observations of thin film reactions of Au on GaAs.

  5. PIC simulation of the vacuum power flow for a 5 terawatt, 5 MV, 1 MA pulsed power system

    NASA Astrophysics Data System (ADS)

    Liu, Laqun; Zou, Wenkang; Liu, Dagang; Guo, Fan; Wang, Huihui; Chen, Lin

    2018-03-01

    In this paper, a 5 Terawatt, 5 MV, 1 MA pulsed power system based on vacuum magnetic insulation is simulated by the particle-in-cell (PIC) simulation method. The system consists of 50 100-kV linear transformer drive (LTD) cavities in series, using magnetically insulated induction voltage adder (MIVA) technology for pulsed power addition and transmission. The pulsed power formation and the vacuum power flow are simulated when the system works in self-limited flow and load-limited flow. When the pulsed power system isn't connected to the load, the downstream magnetically insulated transmission line (MITL) works in the self-limited flow, the maximum of output current is 1.14 MA and the amplitude of voltage is 4.63 MV. The ratio of the electron current to the total current is 67.5%, when the output current reached the peak value. When the impedance of the load is 3.0 Ω, the downstream MITL works in the self-limited flow, the maximums of output current and the amplitude of voltage are 1.28 MA and 3.96 MV, and the ratio of the electron current to the total current is 11.7% when the output current reached the peak value. In addition, when the switches are triggered in synchronism with the passage of the pulse power flow, it effectively reduces the rise time of the pulse current.

  6. Sustained Effects of Ecstasy on the Human Brain: A Prospective Neuroimaging Study in Novel Users

    ERIC Educational Resources Information Center

    de Win, Maartje M. L.; Jager, Gerry; Booij, Jan; Reneman, Liesbeth; Schilt, Thelma; Lavini, Christina; Olabarriaga, Silvia D.; den Heeten, Gerard J.; van den Brink, Wim

    2008-01-01

    Previous studies have suggested toxic effects of recreational ecstasy use on the serotonin system of the brain. However, it cannot be excluded that observed differences between users and non-users are the cause rather than the consequence of ecstasy use. As part of the Netherlands XTC Toxicity (NeXT) study, we prospectively assessed sustained…

  7. Conceptual communications system design in the 25.25-27.5 and 37.0-40.5 GHz frequency bands

    NASA Technical Reports Server (NTRS)

    Thompson, Michael W.

    1993-01-01

    Future space applications are likely to rely heavily on Ka-band frequencies (20-40 GHz) for communications traffic. Many space research activities are now conducted using S-band and X-band frequencies, which are becoming congested and require a degree of pre-coordination. In addition to providing relief from frequency congestion, Ka-band technologies offer potential size, weight, and power savings when compared to lower frequency bands. The use of the 37.0-37.5 and 40.0-40.5 GHz bands for future planetary missions was recently approved at the 1992 World Administrative Radio Conference (WARC-92). WARC-92 also allocated the band 25.25-27.5 GHz to the Intersatellite Service on a primary basis to accommodate Data Relay Satellite return link requirements. Intersatellite links are defined to be between artificial satellites and thus a communication link with the surface of a planetary body, such as the moon, and a relay satellite orbiting that body are not permitted in this frequency band. This report provides information about preliminary communications system concepts for forward and return links for earth-Mars and earth-lunar links using the 37.0-37.5 (return link) and 40.0-40.5 (forward link) GHz frequency bands. In this study we concentrate primarily on a conceptual system for communications between earth and a single lunar surface terminal (LST), and between earth and a single Mars surface terminal (MST). Due to large space losses, these links have the most stringent link requirements for an overall interplanetary system. The earth ground station is assumed to be the Deep Space Network (DSN) using either 34 meter or 70 meter antennas. We also develop preliminary communications concepts for a space-to-space system operating at near 26 GHz. Space-to-space applications can encompass a variety of operating conditions, and we consider several 'typical' scenarios described in more detail later in this report. Among these scenarios are vehicle-to-vehicle communications

  8. OAP- OFFICE AUTOMATION PILOT GRAPHICS DATABASE SYSTEM

    NASA Technical Reports Server (NTRS)

    Ackerson, T.

    1994-01-01

    The Office Automation Pilot (OAP) Graphics Database system offers the IBM PC user assistance in producing a wide variety of graphs and charts. OAP uses a convenient database system, called a chartbase, for creating and maintaining data associated with the charts, and twelve different graphics packages are available to the OAP user. Each of the graphics capabilities is accessed in a similar manner. The user chooses creation, revision, or chartbase/slide show maintenance options from an initial menu. The user may then enter or modify data displayed on a graphic chart. The cursor moves through the chart in a "circular" fashion to facilitate data entries and changes. Various "help" functions and on-screen instructions are available to aid the user. The user data is used to generate the graphics portion of the chart. Completed charts may be displayed in monotone or color, printed, plotted, or stored in the chartbase on the IBM PC. Once completed, the charts may be put in a vector format and plotted for color viewgraphs. The twelve graphics capabilities are divided into three groups: Forms, Structured Charts, and Block Diagrams. There are eight Forms available: 1) Bar/Line Charts, 2) Pie Charts, 3) Milestone Charts, 4) Resources Charts, 5) Earned Value Analysis Charts, 6) Progress/Effort Charts, 7) Travel/Training Charts, and 8) Trend Analysis Charts. There are three Structured Charts available: 1) Bullet Charts, 2) Organization Charts, and 3) Work Breakdown Structure (WBS) Charts. The Block Diagram available is an N x N Chart. Each graphics capability supports a chartbase. The OAP graphics database system provides the IBM PC user with an effective means of managing data which is best interpreted as a graphic display. The OAP graphics database system is written in IBM PASCAL 2.0 and assembler for interactive execution on an IBM PC or XT with at least 384K of memory, and a color graphics adapter and monitor. Printed charts require an Epson, IBM, OKIDATA, or HP Laser

  9. Thermodynamic Modeling of the YO(l.5)-ZrO2 System

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Liu, Zi-Kui; Kaufman, Larry; Zhang, Fan

    2003-01-01

    The YO1.5-ZrO2 system consists of five solid solutions, one liquid solution, and one intermediate compound. A thermodynamic description of this system is developed, which allows calculation of the phase diagram and thermodynamic properties. Two different solution models are used-a neutral species model with YO1.5 and ZrO2 as the components and a charged species model with Y(+3), Zr(+4), O(-2), and vacancies as components. For each model, regular and sub-regular solution parameters are derived fiom selected equilibrium phase and thermodynamic data.

  10. Spectrophotometric Evaluation of Colour Stability of Nano Hybrid Composite Resin in Commonly Used Food Colourants in Asian Countries.

    PubMed

    Chittem, Jyothi; Sajjan, Girija S; Varma Kanumuri, Madhu

    2017-01-01

    There is growing interest in colour stability of aesthetic restorations. So far few studies have been reported. This study was designed to investigate the effects of different common food colourants i.e., Turmeric and Carmoisine (orange red dye) consumed by patients in Asian countries on a recent nano hybrid composite resin. A total of sixty disk shaped specimens measuring 10 mm in diameter and 2 mm in thickness were prepared. The samples were divided into two groups {Z 100 (Dental restorative composite) Filtek Z 250 XT (Nano hybrid universal restorative)}. Baseline colour measurement of all specimens were made using reflectance spectrophotometer with CIE L*a*b* system. Specimens were immersed in artificial saliva and different experimental solutions containing food colourants (carmoisine solution and turmeric solution) for three hours per day at 37°C. Colour measurements were made after 15 days. Colour difference (ΔE*) was calculated. Mean values were compared by one-way analysis of variance (ANOVA). Multiple range test by Tukey Post-hoc test procedure was employed to identify the significant groups at 5% level. Z 100 showed minimum staining capacity when compared to Z 250 XT in both the colourant solutions. The nanohybrid composite resin containing TEGDMA showed significant colour change when compared to that of microhybrid composite resin as a result of staining in turmeric and carmoisine solution.

  11. Development of the 5-HT2CR-Tango System Combined with an EGFP Reporter Gene.

    PubMed

    Watanabe, Yoshihisa; Tsujimura, Atsushi; Aoki, Miku; Taguchi, Katsutoshi; Tanaka, Masaki

    2016-02-01

    The serotonin 2C receptor (5-HT2CR) is a G-protein-coupled receptor implicated in emotion, feeding, reward, and cognition. 5-HT2CRs are pharmacological targets for mental disorders and metabolic and reward system abnormalities, as alterations in 5-HT2CR expression, RNA editing, and SNPs are involved in these disturbances. To date, 5-HT2CR activity has mainly been measured by quantifying inositol phosphate production and intracellular Ca(2+) release, but these assays are not suitable for in vivo analysis. Here, we developed a 5-HT2CR-Tango assay system, a novel analysis tool of 5-HT2CR activity based on the G-protein-coupled receptor (GPCR)-arrestin interaction. With desensitization of activated 5-HT2CR by arrestin, this system converts the 5-HT2CR-arrestin interaction into EGFP reporter gene signal via the LexA transcriptional activation system. For validation of our system, we measured activity of two 5-HT2CR RNA-editing isoforms (INI and VGV) in HEK293 cells transfected with EGFP reporter gene. The INI isoform displayed both higher basal- and 5-HT-stimulated activities than the VGV isoform. Moreover, an inhibitory effect of 5-HT2CR antagonist SB242084 was also detected by 5-HT2CR-Tango system. This novel tool is useful for in vitro high-throughput targeted 5-HT2CR drug screening and can be applied to future in vivo brain function studies associated with 5-HT2CRs in transgenic animal models.

  12. System Simulation of Nuclear Power Plant by Coupling RELAP5 and Matlab/Simulink

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meng Lin; Dong Hou; Zhihong Xu

    2006-07-01

    Since RELAP5 code has general and advanced features in thermal-hydraulic computation, it has been widely used in transient and accident safety analysis, experiment planning analysis, and system simulation, etc. So we wish to design, analyze, verify a new Instrumentation And Control (I and C) system of Nuclear Power Plant (NPP) based on the best-estimated code, and even develop our engineering simulator. But because of limited function of simulating control and protection system in RELAP5, it is necessary to expand the function for high efficient, accurate, flexible design and simulation of I and C system. Matlab/Simulink, a scientific computation software, justmore » can compensate the limitation, which is a powerful tool in research and simulation of plant process control. The software is selected as I and C part to be coupled with RELAP5 code to realize system simulation of NPPs. There are two key techniques to be solved. One is the dynamic data exchange, by which Matlab/Simulink receives plant parameters and returns control results. Database is used to communicate the two codes. Accordingly, Dynamic Link Library (DLL) is applied to link database in RELAP5, while DLL and S-Function is applied in Matlab/Simulink. The other problem is synchronization between the two codes for ensuring consistency in global simulation time. Because Matlab/Simulink always computes faster than RELAP5, the simulation time is sent by RELAP5 and received by Matlab/Simulink. A time control subroutine is added into the simulation procedure of Matlab/Simulink to control its simulation advancement. Through these ways, Matlab/Simulink is dynamically coupled with RELAP5. Thus, in Matlab/Simulink, we can freely design control and protection logic of NPPs and test it with best-estimated plant model feedback. A test will be shown to illuminate that results of coupling calculation are nearly the same with one of single RELAP5 with control logic. In practice, a real Pressurized Water Reactor (PWR

  13. Reversible Parallel Discrete-Event Execution of Large-scale Epidemic Outbreak Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perumalla, Kalyan S; Seal, Sudip K

    2010-01-01

    The spatial scale, runtime speed and behavioral detail of epidemic outbreak simulations together require the use of large-scale parallel processing. In this paper, an optimistic parallel discrete event execution of a reaction-diffusion simulation model of epidemic outbreaks is presented, with an implementation over themore » $$\\mu$$sik simulator. Rollback support is achieved with the development of a novel reversible model that combines reverse computation with a small amount of incremental state saving. Parallel speedup and other runtime performance metrics of the simulation are tested on a small (8,192-core) Blue Gene / P system, while scalability is demonstrated on 65,536 cores of a large Cray XT5 system. Scenarios representing large population sizes (up to several hundred million individuals in the largest case) are exercised.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shamis, Pavel; Graham, Richard L; Gorentla Venkata, Manjunath

    The scalability and performance of collective communication operations limit the scalability and performance of many scientific applications. This paper presents two new blocking and nonblocking Broadcast algorithms for communicators with arbitrary communication topology, and studies their performance. These algorithms benefit from increased concurrency and a reduced memory footprint, making them suitable for use on large-scale systems. Measuring small, medium, and large data Broadcasts on a Cray-XT5, using 24,576 MPI processes, the Cheetah algorithms outperform the native MPI on that system by 51%, 69%, and 9%, respectively, at the same process count. These results demonstrate an algorithmic approach to the implementationmore » of the important class of collective communications, which is high performing, scalable, and also uses resources in a scalable manner.« less

  15. NIMBUS-5 sounder data processing system. Part 2: Results

    NASA Technical Reports Server (NTRS)

    Smith, W. L.; Woolf, H. M.; Hayden, C. M.; Shen, W. C.

    1975-01-01

    The Nimbus-5 spacecraft carries infrared and microwave radiometers for sensing the temperature distribution of the atmosphere. Methods developed for obtaining temperature profiles from the combined set of infrared and microwave radiation measurements are described. Algorithms used to determine (a) vertical temperature and water vapor profiles, (b) cloud height, fractional coverage, and liquid water content, (c) surface temperature, and (d) total outgoing longwave radiation flux are described. Various meteorological results obtained from the application of the Nimbus-5 sounding data processing system during 1973 and 1974 are presented.

  16. Using Heuristics for Supportability Analysis of Adaptive Weapon Systems in Combat

    DTIC Science & Technology

    2017-01-01

    a n/a Customer Requirements Im p o rt an ce w ei g ht f ac to r F o rc e to o p en E xt er na l d im en si o ns C D p o si ti o ni ng f ea tu...usually include Contractor Logistics Support (CLS), and the contract structure normally incentivizes CLS to exceed the KPP Operational Readiness...adaptive baseline, a viable plan for maximizing availability and reducing costs would involve an early design effort for replacing contractor maintenance

  17. Porting and redesign of Geotool software system to Qt

    NASA Astrophysics Data System (ADS)

    Miljanovic Tamarit, V.; Carneiro, L.; Henson, I. H.; Tomuta, E.

    2016-12-01

    Geotool is a software system that allows a user to interactively display and process seismoacoustic data from International Monitoring System (IMS) station. Geotool can be used to perform a number of analysis and review tasks, including data I/O, waveform filtering, quality control, component rotation, amplitude and arrival measurement and review, array beamforming, correlation, Fourier analysis, FK analysis, event review and location, particle motion visualization, polarization analysis, instrument response convolution/deconvolution, real-time display, signal to noise measurement, spectrogram, and travel time model display. The Geotool program was originally written in C using the X11/Xt/Motif libraries for graphics. It was later ported to C++. Now the program is being ported to the Qt graphics system to be more compatible with the other software in the International Data Centre (IDC). Along with this port, a redesign of the architecture is underway to achieve a separation between user interface, control, and data model elements, in line with design patterns such as Model-View-Controller. Qt is a cross-platform application framework that will allow geotool to easily run on Linux, Mac, and Windows. The Qt environment includes modern libraries and user interfaces for standard utilities such as file and database access, printing, and inter-process communications. The Qt Widgets for Technical Applications library (QWT) provides tools for displaying standard data analysis graphics.

  18. CRN5EXP: Expert system for statistical quality control

    NASA Technical Reports Server (NTRS)

    Hentea, Mariana

    1991-01-01

    The purpose of the Expert System CRN5EXP is to assist in checking the quality of the coils at two very important mills: Hot Rolling and Cold Rolling in a steel plant. The system interprets the statistical quality control charts, diagnoses and predicts the quality of the steel. Measurements of process control variables are recorded in a database and sample statistics such as the mean and the range are computed and plotted on a control chart. The chart is analyzed through patterns using the C Language Integrated Production System (CLIPS) and a forward chaining technique to reach a conclusion about the causes of defects and to take management measures for the improvement of the quality control techniques. The Expert System combines the certainty factors associated with the process control variables to predict the quality of the steel. The paper presents the approach to extract data from the database, the reason to combine certainty factors, the architecture and the use of the Expert System. However, the interpretation of control charts patterns requires the human expert's knowledge and lends to Expert Systems rules.

  19. The Effect of a Combination of Implant Controller and Handpiece from Different Manufacturers on the Torque Value.

    PubMed

    Lee, Du-Hyeong; Kim, Yong-Gun; Lee, Jong-Ho; Hong, Sam-Pyo; Lim, Young-Jun; Lee, Kyu-Bok

    2015-01-01

    To determine the accuracy of applied torque of different implant controller and handpiece combinations by using an electronic torque gauge. Four combinations of the following devices were tested: Surgic XT controller (NSK), XIP10 controller (Saeshin), X-SG20L handpiece (NSK), CRB26LX handpiece (Saeshin). For five torque settings, 30 measurements were recorded at 30 revolutions per minute by using an electronic torque gauge fixed to jigs, and means were calculated. Applied torques were generally higher than the set torque of 10 and 20 Ncm and lower than the set values of 40 and 50 Ncm. The average torque deviations differed significantly among the combinations (P < .05). At 10 and 20 Ncm, the Surgic XT/X-SG20L combination yielded the closest value to the intended torque, followed by the XIP10/X-SG20L combination. At 30 Ncm, the XIP10/X-SG20L combination showed the nearest value. At 40 Ncm, the Surgic XT/X-SG20L, XIP10/CRB26LX, and XIP10/X-SG20L combinations showed deviations within 10%. At 50 Ncm, all the combinations showed lower applied torque than the set value. Large standard deviations were observed in the Surgic XT/CRB26LX (13.288) and Surgic XT/X-SG20L (7.858) combinations. Different combinations of implant controllers and handpieces do not generate significant variations in applied torque. The actual torque varies according to the torque setting. It is necessary to calibrate devices before use to reduce potentially problematic torque.

  20. The combined effect of food-simulating solutions, brushing and staining on color stability of composite resins

    PubMed Central

    Silva, Tânia Mara Da; Sales, Ana Luísa Leme Simões; Pucci, Cesar Rogerio; Borges, Alessandra Bühler; Torres, Carlos Rocha Gomes

    2017-01-01

    Abstract Objective: This study evaluated the effect of food-simulating media associated with brushing and coffee staining on color stability of different composite resins. Materials and methods: Eighty specimens were prepared for each composite: Grandio SO (Voco), Amaris (Voco), Filtek Z350XT (3M/ESPE), Filtek P90 (3M/ESPE). They were divided into four groups according to food-simulating media for 7 days: artificial saliva (control), heptane, citric acid and ethanol. The composite surface was submitted to 10,950 brushing cycles (200 g load) in an automatic toothbrushing machine. The specimens were darkened with coffee solution at 37 °C for 24 h. After each treatment, color measurements were assessed by spectrophotometry, using CIE L*a*b* system. The overall color change (ΔE) was determined for each specimen at baseline (C1) and after the treatments (food-simulating media immersion/C2, brushing/C3 and dye solution/C4). Data were analyzed by two-way repeated measures ANOVA and Tukey’s tests (p < .05). Results: The results of RM-ANOVA showed significant differences for composites (p = .001), time (p = .001) and chemical degradation (p = .002). The mean of ΔE for composites were: Z350XT (5.39)a, Amaris (3.89)b, Grandio (3.75)bc, P90 (3.36)c. According to food-simulating media: heptane (4.41)a, citric acid (4.24)a, ethanol (4.02)ab, artificial saliva (3.76)b. For the treatments: dye solution (4.53)a, brushing (4.26)a, after food-simulating media (3.52)b. Conclusions: The composite resin Filtek Z350XT showed significantly higher staining than all other composite resin tested. The immersion in heptane and citric acid produced the highest color alteration than other food-simulating media. The exposure of samples to brushing protocols and darkening in coffee solution resulted in significant color alteration of the composite resins. PMID:28642926

  1. Design, fabrication and testing of a 5-Hz acoustic exciter system

    NASA Technical Reports Server (NTRS)

    Lundy, D. H.; Robinson, G. D.

    1973-01-01

    A 5-Hz acoustic excitation system was designed, fabricated and checked out for use in the modulation of a stagnant gas volume contained in an absorption cell. A detailed system description of the test equipment, both mechanical and electronic, and an operating procedure are included. Conclusions are also presented.

  2. Bond strengths of brackets bonded to enamel surfaces conditioned with femtosecond and Er:YAG laser systems.

    PubMed

    Aglarci, Cahide; Demir, Necla; Aksakalli, Sertac; Dilber, Erhan; Sozer, Ozlem Akinci; Kilic, Hamdi Sukur

    2016-08-01

    The aim of this study was to compare femtosecond and Er:YAG laser systems with regard to enamel demineralization and bracket bond strength. Human-extracted premolars were randomized to three groups (n = 17) depending on the conditioning treatment used for the buccal surfaces: 37 % orthophosphoric acid, Er:YAG laser etching (MSP mode 120 mJ, 10 Hz, 1.2 W), and femtosecond laser etching (0.4 W, 800 nm, 90 fs/pulse, 1 kHz). Metal brackets were bonded with Transbond XT to the conditioned surfaces and light cured for 20 s. The samples were thermocycled (5000 cycles, 5-55 °C) and subjected to shear bond strength (SBS) testing using a universal testing machine. Failure types were analyzed under an optical stereomicroscope and SEM. The adhesive remnant index (ARI) was evaluated to assess residual adhesive on the enamel surface. The results revealed no significant differences in SBS between the Er:YAG laser (7.2 ± 3.3 MPa) and acid etching groups (7.3 ± 2.7 MPa; p < 0.05), whereas a significant difference was observed between the femtosecond laser etching group (3.3 ± 1.2 MPa) and the other two groups (p < 0.01). ARI scores were significantly different among the three groups. The results of our study suggest that laser conditioning with an Er:YAG system results in successful etching, similar to that obtained with acid. The sole use of a femtosecond laser system may not provide an adequate bond strength at the bracket-enamel interface.

  3. Streptococcus mutans forms xylitol-resistant biofilm on excess adhesive flash in novel ex-vivo orthodontic bracket model.

    PubMed

    Ho, Cindy S F; Ming, Yue; Foong, Kelvin W C; Rosa, Vinicius; Thuyen, Truong; Seneviratne, Chaminda J

    2017-04-01

    During orthodontic bonding procedures, excess adhesive is invariably left on the tooth surface at the interface between the bracket and the enamel junction; it is called excess adhesive flash (EAF). We comparatively evaluated the biofilm formation of Streptococcus mutans on EAF produced by 2 adhesives and examined the therapeutic efficacy of xylitol on S mutans formed on EAF. First, we investigated the biofilm formation of S mutans on 3 orthodontic bracket types: stainless steel preadjusted edgewise, ceramic preadjusted edgewise, and stainless steel self-ligating. Subsequently, tooth-colored Transbond XT (3M Unitek, Monrovia, Calif) and green Grengloo (Ormco, Glendora, Calif) adhesives were used for bonding ceramic brackets to extracted teeth. S mutans biofilms on EAF produced by the adhesives were studied using the crystal violet assay and scanning electron microscopy. Surface roughness and surface energy of the EAF were examined. The therapeutic efficacies of different concentrations of xylitol were tested on S mutans biofilms. Significantly higher biofilms were formed on the ceramic preadjusted edgewise brackets (P = 0.003). Transbond XT had significantly higher S mutans biofilms compared with Grengloo surfaces (P = 0.007). There was no significant difference in surface roughness between Transbond XT and Grengloo surfaces (P >0.05). Surface energy of Transbond XT had a considerably smaller contact angle than did Grengloo, suggesting that Transbond XT is a more hydrophilic material. Xylitol at low concentrations had no significant effect on the reduction of S mutans biofilms on orthodontic adhesives (P = 0.016). Transbond XT orthodontic adhesive resulted in more S mutans biofilm compared with Grengloo adhesive on ceramic brackets. Surface energy seemed to play a more important role than surface roughness for the formation of S mutans biofilm on EAF. Xylitol does not appear to have a therapeutic effect on mature S mutans biofilm. Copyright © 2017 American

  4. UniSat-5: a space-based optical system for space debris monitoring

    NASA Astrophysics Data System (ADS)

    Di Roberto, Riccardo; Cappelletti, Chantal

    2012-07-01

    Micro-satellite missions, thanks to the miniaturization process of electronic components, now have a broader range of applications. Gauss Group at School of Aerospace Engineering has been a pioneer in educational micro-satellites, namely with UNISAT and EDUSAT missions. Moreover it has been long involved in space debris related studies, such as optical observations as well as mitigation. A new project is under development for a compact digital imaging system. The purpose will be in situ observation of space debris on board Unisat-5 micro-satellite. One of the key elements of observing on orbit is that many atmospheric phenomena would be avoided, such as diffraction and EM absorption. Hence images would gain more contrast and solar spectral irradiance would be higher for the whole visible spectrum Earlier limitations of power and instrument size prevented the inclusion of these payloads in educational satellite missions. The system is composed of an optical tube, a camera, C band and S band transceivers and two antennas. The system is independent from the rest of the spacecraft. The optical tube is a Schmidt-Cassegrain reflector, and the magnitude limit is 13. The camera is equipped with a panchromatic 5Mpix sensor, capable of direct video streaming, as well as local storage of recorded images. The transceivers operate on ISM 2.4GHz and 5 GHz Wi-Fi bands, and they provide stand-alone communication capabilities to the payload, and Unisat-5 OBDH can switch between the two. Both transceivers are connected to their respective custom-designed patch antenna. The ground segment is constituted of a high gain antenna dish, which will use the same transceiver on board the spacecraft as the feed, in order to establish a TCP/IP wireless link. Every component of this system is a consumer grade product. Therefore price reduction of cutting edge imaging technology now allows the use of professional instruments, that combined with the new wireless technology developed for

  5. 0.5-45GHz Simultaneous Transmit and Receive (STAR) Antenna System for Electronic Attack

    DTIC Science & Technology

    2016-03-17

    0.5-45GHz Simultaneous Transmit and Receive (STAR) Antenna System for Electronic Attack Mohamed Elmansouri, Prathap Valaleprasannakumar, Elie...Colorado, US, 80309 Abstract: A shared antenna aperture for simultaneous transmit and receive (STAR) operating from 0.5 to 45GHz with isolation...50dB over the entire band is discussed. The co-located antenna aperture system is designed across 4 overlapping bands: 0.5-2.5GHz, 2-7GHz, 6-19GHz

  6. Comparison of microleakage in Class II cavities restored with silorane-based and methacrylate-based composite resins using different restorative techniques over time.

    PubMed

    Khosravi, Kazem; Mousavinasab, Seyed-Mostafa; Samani, Mahsa Sahraneshin

    2015-01-01

    Despite the growing tendency toward tooth-colored restorations in dentistry, polymerization shrinkage and subsequent marginal microleakage remains a problem. The aim of this in vitro study was to compare microleakage between silorane-based and methacrylate-based composite resins at different time intervals and with different restorative techniques. In this in vitro study, 108 sound extracted human molar teeth were used. Mesial and distal proximal class II boxes with dimensions of 1.5 mm depth and 4 mm width were prepared. The gingival margins of all cavities were 1 mm below the cement enamel junction. The teeth were randomly divided into three groups based on test materials. In the first group, the teeth were restored by a nanocomposite (Filtek Z350XT, 3MESPE) and SE Bond adhesive (Kuraray, Japan), in the second group, the teeth were restored with a silorane-based (Filtek P90, 3MESPE) and Filtek P90 Adhesive (3M ESPE, USA) and in the third group, the teeth were restored with a microhybrid posterior composite resin (Filtek P60, 3MESPE) and SE Bond adhesive (Kuraray, Japan). Half of the proximal cavities in each of these three groups were restored in two horizontal layers and the other half in four horizontal layers. After a period of aging (24-h, 3-month and 6-month) in water and then application of 500 thermal cycles, the teeth were immersed for 24-h in 0.5% fuchsin and evaluated under a stereomicroscope at ×36 magnification to evaluate leakage in gingival margin. Data was statistically analyzed using Kruskal-Wallis and Mann-Whitney U-tests. P ≤ 0.05 was considered as significant. In Z350XT statistically significant differences were observed in microleakage in comparison of 24-h and 6-month intervals (P = 0.01) that was higher in 6-month. Comparison of microleakage in P90 and P60 composite resins was also statistically significant and was less in P90. Microleakage was not significantly different between P90 and Z350XT at 24-h. However, this difference was

  7. Hybrid Modified K-Means with C4.5 for Intrusion Detection Systems in Multiagent Systems

    PubMed Central

    Laftah Al-Yaseen, Wathiq; Ali Othman, Zulaiha; Ahmad Nazri, Mohd Zakree

    2015-01-01

    Presently, the processing time and performance of intrusion detection systems are of great importance due to the increased speed of traffic data networks and a growing number of attacks on networks and computers. Several approaches have been proposed to address this issue, including hybridizing with several algorithms. However, this paper aims at proposing a hybrid of modified K-means with C4.5 intrusion detection system in a multiagent system (MAS-IDS). The MAS-IDS consists of three agents, namely, coordinator, analysis, and communication agent. The basic concept underpinning the utilized MAS is dividing the large captured network dataset into a number of subsets and distributing these to a number of agents depending on the data network size and core CPU availability. KDD Cup 1999 dataset is used for evaluation. The proposed hybrid modified K-means with C4.5 classification in MAS is developed in JADE platform. The results show that compared to the current methods, the MAS-IDS reduces the IDS processing time by up to 70%, while improving the detection accuracy. PMID:26161437

  8. Hybrid Modified K-Means with C4.5 for Intrusion Detection Systems in Multiagent Systems.

    PubMed

    Laftah Al-Yaseen, Wathiq; Ali Othman, Zulaiha; Ahmad Nazri, Mohd Zakree

    2015-01-01

    Presently, the processing time and performance of intrusion detection systems are of great importance due to the increased speed of traffic data networks and a growing number of attacks on networks and computers. Several approaches have been proposed to address this issue, including hybridizing with several algorithms. However, this paper aims at proposing a hybrid of modified K-means with C4.5 intrusion detection system in a multiagent system (MAS-IDS). The MAS-IDS consists of three agents, namely, coordinator, analysis, and communication agent. The basic concept underpinning the utilized MAS is dividing the large captured network dataset into a number of subsets and distributing these to a number of agents depending on the data network size and core CPU availability. KDD Cup 1999 dataset is used for evaluation. The proposed hybrid modified K-means with C4.5 classification in MAS is developed in JADE platform. The results show that compared to the current methods, the MAS-IDS reduces the IDS processing time by up to 70%, while improving the detection accuracy.

  9. 5. DETAIL VIEW OF OLD, PUNCHTYPE MASTER FIRE ALARM SYSTEM, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. DETAIL VIEW OF OLD, PUNCH-TYPE MASTER FIRE ALARM SYSTEM, LOCATED ON S WALL OF ENGINE STORAGE ROOM; LOOKING S. (Ceronie and Ryan) - Watervliet Arsenal, Building No. 22, Westervelt Avenue & Buffington Street, Watervliet, Albany County, NY

  10. 5 MV 30 mA industrial electron processing system

    NASA Astrophysics Data System (ADS)

    Hoshi, Y.; Mizusawa, K.

    1991-05-01

    Industrial electron beam processing systems have been in use in various application fields such as: improving heat resistivity of wire insulation; controlling quality of automobile rubber tires and melt index characteristics of PE foams; and curing paintings or printing inks. Recently, there has come up a need for electron beam with an energy higher than 3 MV in order to disinfect salmonella in chicken meat, to kill bugs in fruits, and to sterilize medical disposables. To meet this need we developed a 5 MV 30 mA electron processing system with an X-ray conversion target. The machine was tested in NHV's plant in Kyoto at continuous operation of full voltage and full current. It proved to be very steady in operation with a high efficiency (as much as 72%). Also, the X-ray target was tested in a continuous run of 5 MV 30 mA (150 kW). It proved to be viable in industrial utilization. This paper introduces the process and the results of the development.

  11. Structural, Electrical and Magnetic Properties in the System {Na}_{0.5} {CoO}_{3} Na 0.5 CoO 3

    NASA Astrophysics Data System (ADS)

    Estrada Rodriguez, C. A.; Pimentel, J. L.; Turatti, A. M.; Lopes, L. F.; Lopes, R. F.; Parra Vargas, C. A.

    2018-03-01

    The present study reports the structural, magnetic and electrical properties of the Na_{0.5}CoO3 system produced by the conventional solid state reaction method. The X-ray diffraction analysis allows to infer that the compound crystallizes in a monoclinic system with spatial group it{C2/m} and network parameters: a = 5.55 (8) Å, b = 4.87 (3) Å y c = 2.85 (8) Å. It is found that the mean grain size of the stoichiometric of system amounts approximately to 76 nm. Below 40 K, an antiferromagnetic behavior with {T}_{N }≈ 40 K was observed, while in the region between 80 and 190 K the system obeys the law of Curie-Weiss, and the effective magnetic moment was determined experimentally of 5.62{μ }B, indicating a high spin configuration for the Co^{2+ }ion ( S = 3/2) in the fundamental state 4T_{1g}. The system shows cluster spin glass properties with low temperatures, the temperature of magnetic moment freezing from ˜ 40 K. The behavior of the resistivity under absence of magnetic field and the presence of an insulating state between two different metallic states was observed. The metal-insulator transition occurred at two temperatures, the first around 170 K, and the second around 40 K, the latter in accordance with the magnetic transition temperature.

  12. 46 CFR 50.05-5 - Existing boilers, pressure vessels or piping systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Existing boilers, pressure vessels or piping systems. 50... ENGINEERING GENERAL PROVISIONS Application § 50.05-5 Existing boilers, pressure vessels or piping systems. (a) Whenever doubt exists as to the safety of an existing boiler, pressure vessel, or piping system, the marine...

  13. Computer-Aided System Engineering and Analysis (CASE/A) Programmer's Manual, Version 5.0

    NASA Technical Reports Server (NTRS)

    Knox, J. C.

    1996-01-01

    The Computer Aided System Engineering and Analysis (CASE/A) Version 5.0 Programmer's Manual provides the programmer and user with information regarding the internal structure of the CASE/A 5.0 software system. CASE/A 5.0 is a trade study tool that provides modeling/simulation capabilities for analyzing environmental control and life support systems and active thermal control systems. CASE/A has been successfully used in studies such as the evaluation of carbon dioxide removal in the space station. CASE/A modeling provides a graphical and command-driven interface for the user. This interface allows the user to construct a model by placing equipment components in a graphical layout of the system hardware, then connect the components via flow streams and define their operating parameters. Once the equipment is placed, the simulation time and other control parameters can be set to run the simulation based on the model constructed. After completion of the simulation, graphical plots or text files can be obtained for evaluation of the simulation results over time. Additionally, users have the capability to control the simulation and extract information at various times in the simulation (e.g., control equipment operating parameters over the simulation time or extract plot data) by using "User Operations (OPS) Code." This OPS code is written in FORTRAN with a canned set of utility subroutines for performing common tasks. CASE/A version 5.0 software runs under the VAX VMS(Trademark) environment. It utilizes the Tektronics 4014(Trademark) graphics display system and the VTIOO(Trademark) text manipulation/display system.

  14. Land Boundary Conditions for the Goddard Earth Observing System Model Version 5 (GEOS-5) Climate Modeling System: Recent Updates and Data File Descriptions

    NASA Technical Reports Server (NTRS)

    Mahanama, Sarith P.; Koster, Randal D.; Walker, Gregory K.; Takacs, Lawrence L.; Reichle, Rolf H.; De Lannoy, Gabrielle; Liu, Qing; Zhao, Bin; Suarez, Max J.

    2015-01-01

    The Earths land surface boundary conditions in the Goddard Earth Observing System version 5 (GEOS-5) modeling system were updated using recent high spatial and temporal resolution global data products. The updates include: (i) construction of a global 10-arcsec land-ocean lakes-ice mask; (ii) incorporation of a 10-arcsec Globcover 2009 land cover dataset; (iii) implementation of Level 12 Pfafstetter hydrologic catchments; (iv) use of hybridized SRTM global topography data; (v) construction of the HWSDv1.21-STATSGO2 merged global 30 arc second soil mineral and carbon data in conjunction with a highly-refined soil classification system; (vi) production of diffuse visible and near-infrared 8-day MODIS albedo climatologies at 30-arcsec from the period 2001-2011; and (vii) production of the GEOLAND2 and MODIS merged 8-day LAI climatology at 30-arcsec for GEOS-5. The global data sets were preprocessed and used to construct global raster data files for the software (mkCatchParam) that computes parameters on catchment-tiles for various atmospheric grids. The updates also include a few bug fixes in mkCatchParam, as well as changes (improvements in algorithms, etc.) to mkCatchParam that allow it to produce tile-space parameters efficiently for high resolution AGCM grids. The update process also includes the construction of data files describing the vegetation type fractions, soil background albedo, nitrogen deposition and mean annual 2m air temperature to be used with the future Catchment CN model and the global stream channel network to be used with the future global runoff routing model. This report provides detailed descriptions of the data production process and data file format of each updated data set.

  15. Novel orthodontic cement containing dimethylaminohexadecyl methacrylate with strong antibacterial capability.

    PubMed

    Feng, Xiaodong; Zhang, Ning; Xu, Hockin H K; Weir, Michael D; Melo, Mary Anne S; Bai, Yuxing; Zhang, Ke

    2017-09-26

    Orthodontic treatments increase the incidence of white spot lesions. The objectives of this study were to develop an antibacterial orthodontic cement to inhibit demineralization, and to evaluate its enamel shear bond strength and anti-biofilm properties. Novel antibacterial monomer dimethylaminohexadecyl methacrylate (DMAHDM) was synthesized and incorporated into Transbond XT at 0, 1.5 and 3% by mass. Anti-biofilm activity was assessed using a human dental plaque microcosm biofilm model. Shear bond strength and adhesive remnant index were also tested. Biofilm activity precipitously dropped when contacting orthodontic cement with DMAHDM. Orthodontic cement containing 3% DMAHDM significantly reduced biofilm metabolic activity and lactic acid production (p<0.05), and decreased biofilm colony-forming unit (CFU) by two log. Water-aging for 90 days had no adverse influence on enamel shear bond strength (p>0.1). By incorporating DMAHDM into Transbond XT for the first time, the modified orthodontic cement obtained a strong antibacterial capability without compromising the enamel bond strength.

  16. [Musculoskeletal biopsies in an open 0.5-T-MR system].

    PubMed

    Pretzsch, M; Scholz, R; Moche, M; Thomas, M; Tannapfel, A; von Salis-Soglio, G

    2005-01-01

    MR-guided interventions have been successful in different medical disciplines. The aim of this paper is to report our results with the application of MR-guided biopsies of musculoskeletal lesions using an open 0.5-T-MR scanner and further to discuss these results on the basis of the available literature. Between 1998 and 2003 30 patients (average age 44.1 years) underwent a total of 31 biopsies. The interventions were performed in an open 0.5-T MRI system using an active optical localization system as well as a navigation system. For the motion tracking we used T (1)-weighted real-time sequences with 0.25 pictures per second. For the sampling MR-compatible instruments were used that were specially developed for this purpose. The data of this retrospective investigation are based on the evaluation of the patient documents and the radiological findings. On the basis of the histological findings the technical success rate and the histological overall accuracy were determined. In 81 % of the biopsies the histological diagnosis was correct. In cases of suspected inflammation the histological accuracy was smaller (70 %). No differences were observed between skeletal and soft-tissue lesions. The technical success rate amounted to 77.5 %. No procedural or anesthesiological complications occurred. The mean operating time amounted to 65 min including the time for motion tracking. In cases of suspected lesions of the musculoskeletal system, the MR-guided biopsy represents a promising and safe procedure to get a histological diagnosis. In cases of sufficient size of the lesion sampling of a representative probe is possible. On account of the outstanding performance in soft-part contrasting, the sensitive structures surrounding the lesion can be saved. Substantial disadvantages of the procedure are the high costs for personal and material and the long operating time.

  17. Novel procedure for characterizing nonlinear systems with memory: 2017 update

    NASA Astrophysics Data System (ADS)

    Nuttall, Albert H.; Katz, Richard A.; Hughes, Derke R.; Koch, Robert M.

    2017-05-01

    The present article discusses novel improvements in nonlinear signal processing made by the prime algorithm developer, Dr. Albert H. Nuttall and co-authors, a consortium of research scientists from the Naval Undersea Warfare Center Division, Newport, RI. The algorithm, called the Nuttall-Wiener-Volterra or 'NWV' algorithm is named for its principal contributors [1], [2],[ 3] . The NWV algorithm significantly reduces the computational workload for characterizing nonlinear systems with memory. Following this formulation, two measurement waveforms are required in order to characterize a specified nonlinear system under consideration: (1) an excitation input waveform, x(t) (the transmitted signal); and, (2) a response output waveform, z(t) (the received signal). Given these two measurement waveforms for a given propagation channel, a 'kernel' or 'channel response', h= [h0,h1,h2,h3] between the two measurement points, is computed via a least squares approach that optimizes modeled kernel values by performing a best fit between measured response z(t) and a modeled response y(t). New techniques significantly diminish the exponential growth of the number of computed kernel coefficients at second and third order and alleviate the Curse of Dimensionality (COD) in order to realize practical nonlinear solutions of scientific and engineering interest.

  18. Hydrogen-Bonding System in Barium Nitroprusside 6.5-Hydrate

    NASA Astrophysics Data System (ADS)

    Navaza, A.; Chevrier, G.; Guida, J. A.

    1995-01-01

    The hydrogen-bond system in barium nitroprusside 6.5-hydrate, [Ba 2(H 2O) 10][Fe(CN) 5NOl 23H 2O], has been determined by neutron diffraction on monocrystals. Results show the compound to be orthorhombic, space group Cmc2 1 (36), a = 16.008(43), b = 11.550(3), c = 16.648(5) Å, V = 3078(3) Å 3, Z = 4. Refinement of the structure, using 973 observed structure factors, converged to the final RW factor of 0.058. The 2 independent barium atoms, separated 4.60 Å, share a plane of three water molecules forming dimeric tetravalent units. The nitroprusside anions deviate from the C4r ideal symmetry, but this deviation is less than that observed in other nitroprussides. The 10 crystallographically independent water molecules have been classified according to their coordination. Analysis of the H-bond strength, together with a comparison of the packing of the two known barium nitroprusside hydrates (3-hydrate and 6.5-hydrate), suggests that the water molecules labeled as W(1), W(7), W(8), and W(9) could be lost during the partial dehydration of 6.5-hydrate into 3-hydrate.

  19. Does Undersizing of Transcatheter Aortic Valve Bioprostheses during Valve-in-Valve Implantation Avoid Coronary Obstruction? An In Vitro Study.

    PubMed

    Stock, Sina; Scharfschwerdt, Michael; Meyer-Saraei, Roza; Richardt, Doreen; Charitos, Efstratios I; Sievers, Hans-Hinrich; Hanke, Thorsten

    2017-04-01

    Background  The transcatheter aortic valve-in-valve implantation (TAViVI) is an evolving treatment strategy for degenerated surgical aortic valve bioprostheses (SAVBs) in patients with high operative risk. Although hemodynamics is excellent, there is some concern regarding coronary obstruction, especially in SAVB with externally mounted leaflet tissue, such as the Trifecta (St. Jude Medical Inc., St. Paul, Minnesota, United States). We investigated coronary flow and hydrodynamics before and after TAViVI in a SAVB with externally mounted leaflet tissue (St. Jude Medical, Trifecta) with an undersized transcatheter aortic valve bioprosthesis (Edwards Sapien XT; Edwards Lifesciences LLC, Irvine, California, United States) in an in vitro study. Materials and Methods  An aortic root model was constructed incorporating geometric dimensions known as risk factors for coronary obstruction. Investigating the validity of this model, we primarily performed recommended TAViVI with the Sapien XT (size 26 mm) in a Trifecta (size 25 mm) in a mock circulation. Thereafter, hydrodynamic performance and coronary flow (left/right coronary diastolic flow [lCF/rCF]) after TAViVI with an undersized Sapien XT (size 23 mm) in a Trifecta (size 25 mm) were investigated at two different coronary ostia heights (COHs, 8 and 10 mm). Results  Validation of the model led to significant coronary obstruction ( p  < 0.001). Undersized TAViVI showed no significant reduction with respect to coronary flow (lCF: COH 8 mm, 0.90-0.87 mL/stroke; COH 10 mm, 0.89-0.82 mL/stroke and rCF: COH 8 mm, 0.64-0.60 mL/stroke; COH 10 mm, 0.62-0.58 mL/stroke). Mean transvalvular gradients (4-5 mm Hg, p  < 0.001) increased significantly after TAViVI. Conclusions  In our in vitro model, undersized TAViVI with the balloon-expandable Sapien XT into a modern generation SAVB (Trifecta) successfully avoided coronary flow obstruction. Georg Thieme Verlag KG Stuttgart · New York.

  20. Investigation of Differences Between Measured and Predicted Pressures in AEDC/VKF Hypersonic Tunnel B

    DTIC Science & Technology

    1997-01-01

    coordinates are presented in Fig. 4b. The primary calibration data used in this paper is derived from the rake . The 42 pitot probes cov- ered a range...the lateral (YT) direction. Figures 5 and 6 show examples of the pitot pressure and total temperature rake data from a lateral survey and American...Figure 5. Rake pitot measurements, XT = 16 in. 0 10 YT, in. b. Local Mach number 20 Total Temperature Contours, R Static Temperature Contours, R

  1. Finite-Size Scaling Analysis of Binary Stochastic Processes and Universality Classes of Information Cascade Phase Transition

    NASA Astrophysics Data System (ADS)

    Mori, Shintaro; Hisakado, Masato

    2015-05-01

    We propose a finite-size scaling analysis method for binary stochastic processes X(t) in { 0,1} based on the second moment correlation length ξ for the autocorrelation function C(t). The purpose is to clarify the critical properties and provide a new data analysis method for information cascades. As a simple model to represent the different behaviors of subjects in information cascade experiments, we assume that X(t) is a mixture of an independent random variable that takes 1 with probability q and a random variable that depends on the ratio z of the variables taking 1 among recent r variables. We consider two types of the probability f(z) that the latter takes 1: (i) analog [f(z) = z] and (ii) digital [f(z) = θ(z - 1/2)]. We study the universal functions of scaling for ξ and the integrated correlation time τ. For finite r, C(t) decays exponentially as a function of t, and there is only one stable renormalization group (RG) fixed point. In the limit r to ∞ , where X(t) depends on all the previous variables, C(t) in model (i) obeys a power law, and the system becomes scale invariant. In model (ii) with q ≠ 1/2, there are two stable RG fixed points, which correspond to the ordered and disordered phases of the information cascade phase transition with the critical exponents β = 1 and ν|| = 2.

  2. WISE Brown Dwarf Binaries: The Discovery of a T5+T5 and a T8.5+T9 System

    NASA Astrophysics Data System (ADS)

    Gelino, Christopher R.; Kirkpatrick, J. Davy; Cushing, Michael C.; Eisenhardt, Peter R.; Griffith, Roger L.; Mainzer, Amanda K.; Marsh, Kenneth A.; Skrutskie, Michael F.; Wright, Edward L.

    2011-08-01

    The multiplicity properties of brown dwarfs are critical empirical constraints for formation theories, while multiples themselves provide unique opportunities to test evolutionary and atmospheric models and examine empirical trends. Studies using high-resolution imaging cannot only uncover faint companions, but they can also be used to determine dynamical masses through long-term monitoring of binary systems. We have begun a search for the coolest brown dwarfs using preliminary processing of data from the Wide-field Infrared Survey Explorer and have confirmed many of the candidates as late-type T dwarfs. In order to search for companions to these objects, we are conducting observations using the Laser Guide Star Adaptive Optics system on Keck II. Here we present the first results of that search, including a T5 binary with nearly equal mass components and a faint companion to a T8.5 dwarf with an estimated spectral type of T9. Some of the data presented herein were obtained at the W. M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space Administration. The Observatory was made possible by the generous financial support of the W. M. Keck Foundation.

  3. Design and application of a web-based real-time personal PM2.5 exposure monitoring system.

    PubMed

    Sun, Qinghua; Zhuang, Jia; Du, Yanjun; Xu, Dandan; Li, Tiantian

    2018-06-15

    Growing demand from public health research for conduct large-scale epidemiological studies to explore health effect of PM 2.5 was well-documented. To address this need, we design a web-based real-time personal PM 2.5 exposure monitoring system (RPPM2.5 system) which can help researcher to get big data of personal PM 2.5 exposure with low-cost, low labor requirement, and low operating technical requirements. RPPM2.5 system can provide relative accurate real-time personal exposure data for individuals, researches, and decision maker. And this system has been used in a survey of PM 2.5 personal exposure level conducted in 5 cities of China and has provided mass of valuable data for epidemiological research. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. 5 CFR 1330.405 - Procedures for certifying agency appraisal systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Procedures for certifying agency appraisal systems. 1330.405 Section 1330.405 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET JOINT REGULATIONS WITH THE OFFICE OF PERSONNEL MANAGEMENT HUMAN RESOURCES MANAGEMENT Performance Appraisal...

  5. Evaluation and improvement of sticky traps as monitoring tools for Glossina austeni and G. brevipalpis (Diptera: Glossinidae) in north-eastern KwaZulu-Natal, South Africa.

    PubMed

    Green, K Kappmeier; Venter, G J

    2007-12-01

    The attractiveness of various colours, colour combinations and sizes of sticky traps of the 3-dimensional trap (3DT), cross-shaped target (XT), rectangular screen (RT) and monopanels were evaluated for their efficacy to capture Glossina austeni Newstead and G. brevipalpis Newstead in north-eastern KwaZulu-Natal, South Africa. The 3-dimensional shapes of the XT and 3DT in light blue (l.blue) and white were significantly (ca. 3.1-6.9 times) better than the RT for G. austeni. On bicoloured XTs, G. austeni landed preferentially on electric blue (e.blue) (58%) and black (63%) surfaces when used with white; while for G. brevipalpis, significantly more landed on e.blue (60-66%) surfaces when used with l.blue, black or white surfaces. Increased trap size increased the catches of G. brevipalpis females and both sexes of G. austeni significantly. Temoocid and polybutene sticky materials were equally effective and remained durable for 2-3 weeks. The glossy shine of trap surfaces did not have any significant effect on the attraction and landing responses of the two species. The overall trap efficiency of the e.blue/l.blue XT was 23% for G. brevipalpis and 28% for G. austeni, and that of the e.blue/black XT was 16% for G. brevipalpis and 51% for G. austeni. Larger monopanels, painted e.blue/black on both sides, increased the catches of G. austeni females significantly by up to four times compared to the standard e.blue/black XT. This monopanel would be recommended for use as a simple and cost effective survey tool for both species in South Africa.

  6. Novel nano-particles as fillers for an experimental resin-based restorative material.

    PubMed

    Rüttermann, S; Wandrey, C; Raab, W H-M; Janda, R

    2008-11-01

    The purpose of this study is to compare the properties of two experimental materials, nano-material (Nano) and Microhybrid, and two trade products, Clearfil AP-X and Filtek Supreme XT. The flexural strength and modulus after 24h water storage and 5000 thermocycles, water sorption, solubility and X-ray opacity were determined according to ISO 4049. The volumetric behavior (DeltaV) after curing and after water storage was investigated with the Archimedes principle. ANOVA was calculated with p<0.05. Clearfil AP-X showed the highest flexural strength (154+/-14 MPa) and flexural modulus (11,600+/-550 MPa) prior to and after thermocycling (117+/-14 MPa and 13,000+/-300 MPa). The flexural strength of all materials decreased after thermocycling, but the flexural modulus decreased only for Filtek Supreme XT. After thermocycling, there were no significant differences in flexural strength and modulus between Filtek Supreme XT, Microhybrid and Nano. Clearfil AP-X had the lowest water sorption (22+/-1.1 microg mm(-3)) and Nano had the highest water sorption (82+/-2.6 microg mm(-3)) and solubility (27+/-2.9 microg mm(-3)) of all the materials. No significant differences occurred between the solubility of Clearfil AP-X, Filtek Supreme XT and Microhybrid. Microhybrid and Nano provided the highest X-ray opacity. Owing to the lower filler content, Nano showed higher shrinkage than the commercial materials. Nano had the highest expansion after water storage. After thermocycling, Nano performed as well as Filtek Supreme XT for flexural strength, even better for X-ray opacity but significantly worse for flexural modulus, water sorption and solubility. The performances of microhybrids were superior to those of the nano-materials.

  7. The USL NASA PC R and D development environment standards

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Moreau, Dennis R.

    1984-01-01

    The development environment standards which have been established in order to control usage of the IBM PC/XT development systems and to prevent interference between projects being currently developed on the PC's are discussed. The standards address the following areas: scheduling PC resources; login/logout procedures; training; file naming conventions; hard disk organization; diskette care; backup procedures; and copying policies.

  8. Materials interactions between the thermoelectric converter and the 5kwe reactor system

    NASA Technical Reports Server (NTRS)

    Ferry, P. B.

    1973-01-01

    The integration of a compact thermoelectric converter with a 5-kwe reactor system is described. Material interaction uncertainties study is also presented. This includes degradation of the required austenitic - refractory metal transition joint during operation at high temperatures; loss of corrosion resistance; embrittlement by the presence of hydrogen; and loss of design margin by transport of interstitial elements. Analysis and limited experimental evidence indicate that these potential materials interactions can be adequately controlled. Group 5-2 refractory metals can be utilized without unacceptable adverse effect on system reliability.

  9. Investigation of the FK5 system in the equatorial zone. Application to the instrumental system of the Second Quito astrolabe catalogue.

    NASA Astrophysics Data System (ADS)

    Kolesnik, Y. B.

    1995-12-01

    15 catalogues produced in the 1980s and 12 catalogues made from 1960 to 1978 have been used to assess the consistency of the FK5 system with observations in the declination zone from -30deg to 30deg. Classical δ-dependent and α-dependent systematic differences (Cat-FK5) have been formed for individual instrumental systems of the catalogues. The weighted mean instrumental systems for two subsets of catalogues centred at the epochs 1970 and 1987 have been constructed. External systematic and random accuracy of the catalogues under analysis and errors of the mean instrumental systems for both selections of catalogues have been estimated and presented in tables. The individual systematic differences of the catalogues and the mean instrumental systems are shown in figures. Numerical values of the total systematic deviations for both mean instrumental systems are given in tables. The results of intercomparison are discussed to assess the actual systematic deviations of the FK5 at the respective epochs and its actual random accuracy. It has been found that the mutual consistency of individual instrumental systems of catalogues of 1980s with respect to zonal systematic differences in both right ascension and declination is significantly better when comparing with the earlier catalogues. Consistency of both catalogue subsets is comparable with respect to α-dependent systematic differences. It is shown that the claimed random errors of the FK5 positions and proper motions are rather realistic, while deviations of the FK5 right ascension and declination system in the equatorial zone for both mean epochs exceed expected ones from the formal considerations. Quick degradation of the FK5 system with time is detected in right ascension. The results in declination are recognized to be less reliable, due to larger inconsistency of the individual instrumental systems. The system of the Second Quito Astrolabe Catalogue (QAC 2) has been investigated by comparison with two subsets of

  10. Effect of saliva contamination on cementation of orthodontic brackets using different adhesive systems.

    PubMed

    Robaski, Aliden-Willian; Pamato, Saulo; Tomás-de Oliveira, Marcelo; Pereira, Jefferson-Ricardo

    2017-07-01

    The enamel condition and the quality of surface are points that need to be considered for achieving optimal efficiency in the treatment with orthodontic brackets. The aim of this study was to assess the immediate bond strength of metallic brackets cemented to dental. Forty human premolars were double-sectioned, placed in PVC matrices and randomly divided into 10 groups (n=8). They received artificial saliva contamination before or after the application of adhesive systems, except for the control groups. The metallic brackets were cemented using two orthodontic cements (Transbond™ Plus Color Change, 3M Unitek e Transbond™ XT Light, 3M Unitek). The specimens were subjected to mechanical shear bond strength testing and classified according to the fracture pattern. The results were analyzed using a two-way ANOVA and Tukey's test for multiple comparisons ( p <0.05). ANOVA analysis showed statistically significant differences between the groups ( p =0.01). The Tukey's multiple comparison test indicated statistically significant difference between G6 and G7 groups ( p <0.05). A high prevalence of adhesive failure in the groups receiving the hydrophobic adhesive system. The saliva contamination prior to the application of a hydrophobic simplified conventional adhesive system was responsible for decreasing the immediate bond strength values of brackets cemented on the dental enamel. Key words: Bonding, orthodontic brackets, shear bond strength, saliva, adhesive systems.

  11. Understanding Aprun Use Patterns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Hwa-Chun Wendy

    2009-05-06

    On the Cray XT, aprun is the command to launch an application to a set of compute nodes reserved through the Application Level Placement Scheduler (ALPS). At the National Energy Research Scientific Computing Center (NERSC), interactive aprun is disabled. That is, invocations of aprun have to go through the batch system. Batch scripts can and often do contain several apruns which either use subsets of the reserved nodes in parallel, or use all reserved nodes in consecutive apruns. In order to better understand how NERSC users run on the XT, it is necessary to associate aprun information with jobs. Itmore » is surprisingly more challenging than it sounds. In this paper, we describe those challenges and how we solved them to produce daily per-job reports for completed apruns. We also describe additional uses of the data, e.g. adjusting charging policy accordingly or associating node failures with jobs/users, and plans for enhancements.« less

  12. Parallel implementation of a Lagrangian-based model on an adaptive mesh in C++: Application to sea-ice

    NASA Astrophysics Data System (ADS)

    Samaké, Abdoulaye; Rampal, Pierre; Bouillon, Sylvain; Ólason, Einar

    2017-12-01

    We present a parallel implementation framework for a new dynamic/thermodynamic sea-ice model, called neXtSIM, based on the Elasto-Brittle rheology and using an adaptive mesh. The spatial discretisation of the model is done using the finite-element method. The temporal discretisation is semi-implicit and the advection is achieved using either a pure Lagrangian scheme or an Arbitrary Lagrangian Eulerian scheme (ALE). The parallel implementation presented here focuses on the distributed-memory approach using the message-passing library MPI. The efficiency and the scalability of the parallel algorithms are illustrated by the numerical experiments performed using up to 500 processor cores of a cluster computing system. The performance obtained by the proposed parallel implementation of the neXtSIM code is shown being sufficient to perform simulations for state-of-the-art sea ice forecasting and geophysical process studies over geographical domain of several millions squared kilometers like the Arctic region.

  13. 5 CFR 430.405 - Procedures for certifying agency appraisal systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... information; (ii) Applicable administrative instructions and implementing guidance; and (iii) The system's use of rating levels that are capable of clearly differentiating among senior employees based on..., and which include— (A) For the agency's senior executives covered by 5 CFR part 430, subpart C, at...

  14. Construction of a fast, inexpensive rapid-scanning diode-array detector and spectrometer.

    PubMed

    Carter, T P; Baek, H K; Bonninghausen, L; Morris, R J; van Wart, H E

    1990-10-01

    A 512-element diode-array spectroscopic detection system capable of acquiring multiple spectra at a rate of 5 ms per spectrum with an effective scan rate of 102.9 kHz has been constructed. Spectra with fewer diode elements can also be acquired at scan rates up to 128 kHz. The detector utilizes a Hamamatsu silicon photodiode-array sensor that is interfaced to Hamamatsu driver/amplifier and clock generator boards and a DRA laboratories 12-bit 160-kHz analog-to-digital converter. These are standard, commercially available devices which cost approximately $3500. The system is interfaced to and controlled by an IBM XT microcomputer. Detailed descriptions of the home-built detector housing and control/interface circuitry are presented and its application to the study of the reaction of horseradish peroxidase with hydrogen peroxide is demonstrated.

  15. 6 CFR Appendix C to Part 5 - DHS Systems of Records Exempt From the Privacy Act

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... DISCLOSURE OF RECORDS AND INFORMATION Pt. 5, App. C Appendix C to Part 5—DHS Systems of Records Exempt From... Homeland Security (DHS) Freedom of Information Act (FOIA) and Privacy Act (PA) Record System allows the DHS... information contained in other systems of records subject to such exemptions pursuant to 5 U.S.C. 552a(j)(2...

  16. Effect of Nanoscale Fillers on the Local Mechanical Behavior of Polymer Nanocomposites

    DTIC Science & Technology

    2009-12-01

    the interparticle spacing can be related to the particle volume fraction, vp, and the particle diameter, d, by [2] r = d 6v„ d) I I (b) Figure...VGCNFs), namely as- fabricated (PR-24-XT PS), high temperature hear treated (PR-24-XT-HHT-LD), and high temperature hear treated and oxidatively...Therefore, hear treatment had a severe effect on the fracture toughness of composites with embedded VGCNFs. This agrees with composite level

  17. A scoring system to predict breast cancer mortality at 5 and 10 years.

    PubMed

    Paredes-Aracil, Esther; Palazón-Bru, Antonio; Folgado-de la Rosa, David Manuel; Ots-Gutiérrez, José Ramón; Compañ-Rosique, Antonio Fernando; Gil-Guillén, Vicente Francisco

    2017-03-24

    Although predictive models exist for mortality in breast cancer (BC) (generally all cause-mortality), they are not applicable to all patients and their statistical methodology is not the most powerful to develop a predictive model. Consequently, we developed a predictive model specific for BC mortality at 5 and 10 years resolving the above issues. This cohort study included 287 patients diagnosed with BC in a Spanish region in 2003-2016. time-to-BC death. Secondary variables: age, personal history of breast surgery, personal history of any cancer/BC, premenopause, postmenopause, grade, estrogen receptor, progesterone receptor, c-erbB2, TNM stage, multicentricity/multifocality, diagnosis and treatment. A points system was constructed to predict BC mortality at 5 and 10 years. The model was internally validated by bootstrapping. The points system was integrated into a mobile application for Android. Mean follow-up was 8.6 ± 3.5 years and 55 patients died of BC. The points system included age, personal history of BC, grade, TNM stage and multicentricity. Validation was satisfactory, in both discrimination and calibration. In conclusion, we constructed and internally validated a scoring system for predicting BC mortality at 5 and 10 years. External validation studies are needed for its use in other geographical areas.

  18. Systemic Regulation of RAS/MAPK Signaling by the Serotonin Metabolite 5-HIAA.

    PubMed

    Schmid, Tobias; Snoek, L Basten; Fröhli, Erika; van der Bent, M Leontien; Kammenga, Jan; Hajnal, Alex

    2015-05-01

    Human cancer is caused by the interplay of mutations in oncogenes and tumor suppressor genes and inherited variations in cancer susceptibility genes. While many of the tumor initiating mutations are well characterized, the effect of genetic background variation on disease onset and progression is less understood. We have used C. elegans genetics to identify genetic modifiers of the oncogenic RAS/MAPK signaling pathway. Quantitative trait locus analysis of two highly diverged C. elegans isolates combined with allele swapping experiments identified the polymorphic monoamine oxidase A (MAOA) gene amx-2 as a negative regulator of RAS/MAPK signaling. We further show that the serotonin metabolite 5-hydroxyindoleacetic acid (5-HIAA), which is a product of MAOA catalysis, systemically inhibits RAS/MAPK signaling in different organs of C. elegans. Thus, MAOA activity sets a global threshold for MAPK activation by controlling 5-HIAA levels. To our knowledge, 5-HIAA is the first endogenous small molecule that acts as a systemic inhibitor of RAS/MAPK signaling.

  19. Analysis of Characteristics and Requirements for 5G Mobile Communication Systems

    NASA Astrophysics Data System (ADS)

    Ancans, G.; Stafecka, A.; Bobrovs, V.; Ancans, A.; Caiko, J.

    2017-08-01

    One of the main objectives of the fifth generation (5G) mobile communication systems, also known as IMT-2020, is to increase the current data rates up to several gigabits per second (Gbit/s) or even up to 10 Gbit/s and higher. One of the possibilities to consider is the use of higher frequencies in order to enlarge the available bandwidth. Wider bandwidth is necessary to achieve much higher data rates. It should be noted that wireless broadband transmission technologies require frequencies for their development. The main goal of the research is to investigate the characteristics and requirements of 5G mobile communication systems. The paper provides an insight into deployment scenario and radio wave propagation in frequencies above 24 GHz of IMT-2020.

  20. Nonparametric Statistics Test Software Package.

    DTIC Science & Technology

    1983-09-01

    statis- tics because of their acceptance in the academic world, the availability of computer support, and flexibility in model builling. Nonparametric...25 I1l,lCELL WRITE(NCF,12 ) IvE (I ,RCCT(I) 122 FORMAT(IlXt 3(H5 9 1) IF( IeLT *NCELL) WRITE (NOF1123 J PARTV(I1J 123 FORMAT( Xll----’,FIo.3J 25 CONT

  1. An efficient supersonic wind tunnel drive system for Mach 2.5 flows

    NASA Technical Reports Server (NTRS)

    Wolf, Stephen W. D.; Laub, James A.; King, Lyndell S.

    1991-01-01

    A novel efficient drive system has been developed which provides for the continuous operation of a pitot Mach 2.5 wind tunnel at compression ratios down to 0.625:1. The drive system does not require an overpressure to start, and no hysteresis has been observed. The general design of the proof-of-concept wind tunnel using the new drive system and its modifications are described.

  2. Proceedings of the Annual Conference of the Military Testing Association (27th) Held in San Diego, California on 21-25 October 1985. Volume 2

    DTIC Science & Technology

    1985-10-25

    supports. Study II was intended as a replication of Study I. Study Ill was de - signed to follow up on the unexpected outcomes of Studies I and II, In...cadre varied widely. Some responded to increased contact with more support for this study, some de - veloped a vested interest in their own cadets...usable results applicable to both the San De ,go and Washington areas. SYSTEM DESIGN The system components consisted of IBM PC AT & XT’: with specially

  3. x-y-recording in transmission electron microscopy. A versatile and inexpensive interface to personal computers with application to stereology.

    PubMed

    Rickmann, M; Siklós, L; Joó, F; Wolff, J R

    1990-09-01

    An interface for IBM XT/AT-compatible computers is described which has been designed to read the actual specimen stage position of electron microscopes. The complete system consists of (i) optical incremental encoders attached to the x- and y-stage drivers of the microscope, (ii) two keypads for operator input, (iii) an interface card fitted to the bus of the personal computer, (iv) a standard configuration IBM XT (or compatible) personal computer optionally equipped with a (v) HP Graphic Language controllable colour plotter. The small size of the encoders and their connection to the stage drivers by simple ribbed belts allows an easy adaptation of the system to most electron microscopes. Operation of the interface card itself is supported by any high-level language available for personal computers. By the modular concept of these languages, the system can be customized to various applications, and no computer expertise is needed for actual operation. The present configuration offers an inexpensive attachment, which covers a wide range of applications from a simple notebook to high-resolution (200-nm) mapping of tissue. Since section coordinates can be processed in real-time, stereological estimations can be derived directly "on microscope". This is exemplified by an application in which particle numbers were determined by the disector method.

  4. Quantifying phase synchronization using instances of Hilbert phase slips

    NASA Astrophysics Data System (ADS)

    Govindan, R. B.

    2018-07-01

    We propose to quantify phase synchronization between two signals, x(t) and y(t), by calculating variance in the Hilbert phase of y(t) at instances of phase slips exhibited by x(t). The proposed approach is tested on numerically simulated coupled chaotic Roessler systems and second order autoregressive processes. Furthermore we compare the performance of the proposed and original approaches using uterine electromyogram signals and show that both approaches yield consistent results A standard phase synchronization approach, which involves unwrapping the Hilbert phases (ϕ1(t) and ϕ2(t)) of the two signals and analyzing the variance in the | n ṡϕ1(t) - m ṡϕ2(t) | , mod 2 π, (n and m are integers), was used for comparison. The synchronization indexes obtained from the proposed approach and the standard approach agree reasonably well in all of the systems studied in this work. Our results indicate that the proposed approach, unlike the traditional approach, does not require the non-invertible transformations - unwrapping of the phases and calculation of mod 2 π and it can be used to reliably to quantify phase synchrony between two signals.

  5. A T8.5 BROWN DWARF MEMBER OF THE {xi} URSAE MAJORIS SYSTEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, Edward L.; Mace, Gregory; McLean, Ian S.

    The Wide-field Infrared Survey Explorer has revealed a T8.5 brown dwarf (WISE J111838.70+312537.9) that exhibits common proper motion with a solar-neighborhood (8 pc) quadruple star system-{xi} Ursae Majoris. The angular separation is 8.'5, and the projected physical separation is Almost-Equal-To 4000 AU. The sub-solar metallicity and low chromospheric activity of {xi} UMa A argue that the system has an age of at least 2 Gyr. The infrared luminosity and color of the brown dwarf suggests the mass of this companion ranges between 14 and 38 M{sub J} for system ages of 2 and 8 Gyr, respectively.

  6. Parallel Flux Tensor Analysis for Efficient Moving Object Detection

    DTIC Science & Technology

    2011-07-01

    computing as well as parallelization to enable real time performance in analyzing complex video [3, 4 ]. There are a number of challenging computer vision... 4 . TITLE AND SUBTITLE Parallel Flux Tensor Analysis for Efficient Moving Object Detection 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...We use the trace of the flux tensor matrix, referred to as Tr JF , that is defined below, Tr JF = ∫ Ω W (x− y)(I2xt(y) + I2yt(y) + I2tt(y))dy ( 4 ) as

  7. ENSO Prediction in the NASA GMAO GEOS-5 Seasonal Forecasting System

    NASA Astrophysics Data System (ADS)

    Kovach, R. M.; Borovikov, A.; Marshak, J.; Pawson, S.; Vernieres, G.

    2016-12-01

    Seasonal-to-Interannual coupled forecasts are conducted in near-real time with the Goddard Earth Observing System (GEOS) Atmosphere-Ocean General Circulation Model (AOGCM). A 30-year suite of 9-month hindcasts is available, initialized with the MERRA-Ocean, MERRA-Land, and MERRA atmospheric fields. These forecasts are used to predict the timing and magnitude of ENSO and other short-term climate variability. The 2015 El Niño peaked in November 2015 and was considered a "very strong" event with the Equatorial Pacific Ocean sea-surface-temperature (SST) anomalies higher than 2.0 °C. These very strong temperature anomalies began in Sep/Oct/Nov (SON) of 2015 and persisted through Dec/Jan/Feb (DJF) of 2016. The other two very strong El Niño events recently recorded occurred in 1981/82 and 1997/98. The GEOS-5 system began predicting a very strong El Niño for SON starting with the March 2015 forecast. At this time, the GMAO forecast was an outlier in both the NMME and IRI multi-model ensemble prediction plumes. The GMAO May 2015 forecast for the November 2015 peak in temperature anomaly in the Niño3.4 region was in excellent agreement with the real event, but in May this forecast was still one of the outliers in the multi-model forecasts. The GEOS-5 May 2015 forecast also correctly predicted the weakening of the Eastern Pacific (Niño1+2) anomalies for SON. We will present a summary of the NASA GMAO GEOS-5 Seasonal Forecast System skills based on historic hindcasts. Initial conditions, prediction of ocean surface and subsurface evolution for the 2015/16 El Niño will be compared to the 1998/97 event. GEOS-5 capability to predict the precipitation, i.e. to model the teleconnection patterns associated with El Niño will also be shown. To conclude, we will highlight some new developments in the GEOS forecasting system.

  8. Gluconacetobacter diazotrophicus PAL5 possesses an active quorum sensing regulatory system.

    PubMed

    Bertini, Elisa V; Nieto Peñalver, Carlos G; Leguina, Ana C; Irazusta, Verónica P; de Figueroa, Lucía I C

    2014-09-01

    The endophytic bacterium Gluconacetobacter diazotrophicus colonizes a broad range of host plants. Its plant growth-promoting capability is related to the capacity to perform biological nitrogen fixation, the biosynthesis of siderophores, antimicrobial substances and the solubilization of mineral nutrients. Colonization of and survival in these endophytic niche requires a complex regulatory network. Among these, quorum sensing systems (QS) are signaling mechanisms involved in the control of several genes related to microbial interactions, host colonization and stress survival. G. diazotrophicus PAL5 possesses a QS composed of a luxR and a luxI homolog, and produces eight molecules from the AHL family as QS signals. In this report data are provided showing that glucose concentration modifies the relative levels of these signal molecules. The activity of G. diazotrophicus PAL5 QS is also altered in presence of other carbon sources and under saline stress conditions. Inactivation of the QS system of G. diazotrophicus PAL5 by means of a quorum quenching strategy allowed the identification of extracellular and intracellular proteins under the control of this regulatory mechanism.

  9. 32 CFR 323.5 - Access to systems of records information.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) PRIVACY PROGRAM DEFENSE LOGISTICS AGENCY PRIVACY PROGRAM § 323.5 Access to systems of records... Logistics Agency, ATTN: DGA, 8725 John J. Kingman Road, Suite 1644, Fort Belvoir, VA 22060-6221. Any written... General Counsel, Defense Logistics Agency, ATTN: DGA, Suite 1644, 8725 John J. Kingman Road, Fort Belvoir...

  10. 32 CFR 323.5 - Access to systems of records information.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) PRIVACY PROGRAM DEFENSE LOGISTICS AGENCY PRIVACY PROGRAM § 323.5 Access to systems of records... Logistics Agency, ATTN: DGA, 8725 John J. Kingman Road, Suite 1644, Fort Belvoir, VA 22060-6221. Any written... General Counsel, Defense Logistics Agency, ATTN: DGA, Suite 1644, 8725 John J. Kingman Road, Fort Belvoir...

  11. Impact of rheology on probabilistic forecasts of sea ice trajectories: application for search and rescue operations in the Arctic

    NASA Astrophysics Data System (ADS)

    Rabatel, Matthias; Rampal, Pierre; Carrassi, Alberto; Bertino, Laurent; Jones, Christopher K. R. T.

    2018-03-01

    We present a sensitivity analysis and discuss the probabilistic forecast capabilities of the novel sea ice model neXtSIM used in hindcast mode. The study pertains to the response of the model to the uncertainty on winds using probabilistic forecasts of ice trajectories. neXtSIM is a continuous Lagrangian numerical model that uses an elasto-brittle rheology to simulate the ice response to external forces. The sensitivity analysis is based on a Monte Carlo sampling of 12 members. The response of the model to the uncertainties is evaluated in terms of simulated ice drift distances from their initial positions, and from the mean position of the ensemble, over the mid-term forecast horizon of 10 days. The simulated ice drift is decomposed into advective and diffusive parts that are characterised separately both spatially and temporally and compared to what is obtained with a free-drift model, that is, when the ice rheology does not play any role in the modelled physics of the ice. The seasonal variability of the model sensitivity is presented and shows the role of the ice compactness and rheology in the ice drift response at both local and regional scales in the Arctic. Indeed, the ice drift simulated by neXtSIM in summer is close to the one obtained with the free-drift model, while the more compact and solid ice pack shows a significantly different mechanical and drift behaviour in winter. For the winter period analysed in this study, we also show that, in contrast to the free-drift model, neXtSIM reproduces the sea ice Lagrangian diffusion regimes as found from observed trajectories. The forecast capability of neXtSIM is also evaluated using a large set of real buoy's trajectories and compared to the capability of the free-drift model. We found that neXtSIM performs significantly better in simulating sea ice drift, both in terms of forecast error and as a tool to assist search and rescue operations, although the sources of uncertainties assumed for the present

  12. Treating childhood intermittent distance exotropia: a qualitative study of decision making.

    PubMed

    Lecouturier, Jan; Clarke, Michael P; Errington, Gail; Hallowell, Nina; Murtagh, Madeleine J; Thomson, Richard

    2015-08-22

    Engaging patients (parents/families) in treatment decisions is increasingly recognised as important and beneficial. Yet where the evidence base for treatment options is limited, as with intermittent distance exotropia (X(T)), this presents a challenge for families and clinicians. The purpose of this study was to explore how decisions are made in the management and treatment of X(T) and what can be done to support decision-making for clinicians, parents and children. This was a qualitative study using face to face interviews with consultant ophthalmologists and orthoptists, and parents of children with X(T). Interview data were analysed using the constant comparative method. The drivers for clinicians in treatment decision-making for X(T) were the proportion of time the strabismus is manifest and parents' views. For parents, decisions were influenced by: fear of bullying and, to a lesser degree, concerns around the impact of the strabismus on their child's vision. Uncertainty around the effectiveness of treatment options caused difficulties for some clinicians when communicating with parents. Parental understanding of the nature of X(T) and rationale for treatment often differed from that of the clinicians, and this affected their involvement in decision-making. Though there were good examples of shared decision-making and parent and child engagement some parents said the process felt rushed and they felt excluded. Parents reported that clinicians provided sufficient information in consultations but they had difficulties in retaining verbal information to convey to other family members. Overall parents were happy with the care their child received but there is scope for better parent and (where appropriate) child engagement in decision-making. There was an expressed need for written information about X(T) to reinforce what was given verbally in consultations and to share with other family members. Access could be via the hospital website, along with videos or blogs

  13. Earth Observatory Satellite system definition study. Report 5: System design and specifications. Volume 1: Baseline system description

    NASA Technical Reports Server (NTRS)

    1974-01-01

    A system baseline design oriented to the requirements of the next generation of Earth Observatory Satellite missions is presented. The first mission (EOS-A) is envisioned as a two-fold mission which (1) provides a continuum of data of the type being supplied by ERTS for the emerging operational applications and also (2) expands the research and development activities for future instrumentation and analysis techniques. The baseline system specifically satisfies the requirements of this first mission. However, EOS-A is expected to be the first of a series of earth observation missions. Thus the baseline design has been developed so as to accommodate these latter missions effectively as the transition is made from conventional, expendable launch vehicles and spacecraft to the Shuttle Space Transportation System era. Further, a subset of alternative missions requirements including Seasat, SEOS, SMM and MSS-5 have been analyzed to verify that the spacecraft design to serve a multi-mission role is economically sound. A key feature of the baseline system design is the concept of a modular observatory system whose elements are compatible with varying levels of launch vehicle capability. The design configuration can be used with either the Delta or Titan launch vehicles and will adapt readily to the space shuttle when that system becomes available in the early 1980's.

  14. The thermal degradation of 5 alpha (H)-cholestane during closed-system pyrolysis

    NASA Astrophysics Data System (ADS)

    Abbott, Geoffrey D.; Bennett, Barry; Stuart Fetch, G.

    1995-06-01

    Involatile hydrocarbons were identified following the heating of 5α(H)-cholestane in water with reaction vessel walls composed of 316 grade stainless steel and borosilicate glass. These analyses were compared with the hydrocarbon product compositions from closed-system pyrolysis experiments with no added water. Unsaturated hydrocarbons dominate their saturated counterparts following hydrous pyrolysis in both stainless steel-316 and borosilicate glass. In the absence of added water the converse is true in that saturated components dominate the hydrocarbon mixture. Backbone rearrangement in the steroid nucleus leading to spirosterene formation was only observed under aqueous conditions in both borosilicate glass and stainless steel-316 vessels. These comparisons demonstrate that water, as opposed to reaction vessel surface catalytic effects, plays a central role in mediating hydrocarbon degradation during closed-system hydrous pyrolysis. 5α(H)-cholestane degradation under aqueous conditions is a complex composite of dissociative and rearrangement processes. These include (I) carbon-carbon bond cleavage in the sidechains as well as the ring system, (2) dehydrogenation, and (3) backbone rearrangement. These laboratory experiments provide a product description of the involatile hydrocarbons which will be the basis for a mechanistic study of 5α(H)-cholestane degradation in hot water.

  15. Performance comparison of two commercial human whole-exome capture systems on formalin-fixed paraffin-embedded lung adenocarcinoma samples.

    PubMed

    Bonfiglio, Silvia; Vanni, Irene; Rossella, Valeria; Truini, Anna; Lazarevic, Dejan; Dal Bello, Maria Giovanna; Alama, Angela; Mora, Marco; Rijavec, Erika; Genova, Carlo; Cittaro, Davide; Grossi, Francesco; Coco, Simona

    2016-08-30

    Next Generation Sequencing (NGS) has become a valuable tool for molecular landscape characterization of cancer genomes, leading to a better understanding of tumor onset and progression, and opening new avenues in translational oncology. Formalin-fixed paraffin-embedded (FFPE) tissue is the method of choice for storage of clinical samples, however low quality of FFPE genomic DNA (gDNA) can limit its use for downstream applications. To investigate the FFPE specimen suitability for NGS analysis and to establish the performance of two solution-based exome capture technologies, we compared the whole-exome sequencing (WES) data of gDNA extracted from 5 fresh frozen (FF) and 5 matched FFPE lung adenocarcinoma tissues using: SeqCap EZ Human Exome v.3.0 (Roche NimbleGen) and SureSelect XT Human All Exon v.5 (Agilent Technologies). Sequencing metrics on Illumina HiSeq were optimal for both exome systems and comparable among FFPE and FF samples, with a slight increase of PCR duplicates in FFPE, mainly in Roche NimbleGen libraries. Comparison of single nucleotide variants (SNVs) between FFPE-FF pairs reached overlapping values >90 % in both systems. Both WES showed high concordance with target re-sequencing data by Ion PGM™ in 22 lung-cancer genes, regardless the source of samples. Exon coverage of 623 cancer-related genes revealed high coverage efficiency of both kits, proposing WES as a valid alternative to target re-sequencing. High-quality and reliable data can be successfully obtained from WES of FFPE samples starting from a relatively low amount of input gDNA, suggesting the inclusion of NGS-based tests into clinical contest. In conclusion, our analysis suggests that the WES approach could be extended to a translational research context as well as to the clinic (e.g. to study rare malignancies), where the simultaneous analysis of the whole coding region of the genome may help in the detection of cancer-linked variants.

  16. Extended System Operations Studies for Automated Guideway Transit Systems : Plan for Task 5--DPM Failure Management

    DOT National Transportation Integrated Search

    1981-06-01

    The purpose of Task 5 in the Extended System Operations Studies Project, DPM Failure Management, is to enhance the capabilities of the Downtown People Mover Simulation (DPMS) and the Discrete Event Simulation Model (DESM) by increasing the failure mo...

  17. LGR5/GPR49 is implicated in motor neuron specification in nervous system.

    PubMed

    Song, Shao-jun; Mao, Xing-gang; Wang, Chao; Han, An-guo; Yan, Ming; Xue, Xiao-yan

    2015-01-01

    The biological roles of stem cell marker LGR5, the receptor for the Wnt-agonistic R-spondins, for nervous system are poorly known. Bioinformatics analysis in normal human brain tissues revealed that LGR5 is closely related with neuron development and functions. Interestingly, LGR5 and its ligands R-spondins (RSPO2 and RSPO3) are specifically highly expressed in projection motor neurons in the spinal cord, brain stem and cerebral. Inhibition of Notch activity in neural stem cells (NSCs) increased the percentage of neuronal cells and promoted LGR5 expression, while activation of Notch signal decreased neuronal cells and inhibited the LGR5 expression. Furthermore, knockdown of LGR5 inhibited the expression of neuronal markers MAP2, NeuN, GAP43, SYP and CHRM3, and also reduced the expression of genes that program the identity of motor neurons, including Isl1, Lhx3, PHOX2A, TBX20 and NEUROG2. Our data demonstrated that LGR5 is highly expressed in motor neurons in nervous system and is involved in their development by regulating transcription factors that program motor neuron identity. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. TWOS - TIME WARP OPERATING SYSTEM, VERSION 2.5.1

    NASA Technical Reports Server (NTRS)

    Bellenot, S. F.

    1994-01-01

    The Time Warp Operating System (TWOS) is a special-purpose operating system designed to support parallel discrete-event simulation. TWOS is a complete implementation of the Time Warp mechanism, a distributed protocol for virtual time synchronization based on process rollback and message annihilation. Version 2.5.1 supports simulations and other computations using both virtual time and dynamic load balancing; it does not support general time-sharing or multi-process jobs using conventional message synchronization and communication. The program utilizes the underlying operating system's resources. TWOS runs a single simulation at a time, executing it concurrently on as many processors of a distributed system as are allocated. The simulation needs only to be decomposed into objects (logical processes) that interact through time-stamped messages. TWOS provides transparent synchronization. The user does not have to add any more special logic to aid in synchronization, nor give any synchronization advice, nor even understand much about how the Time Warp mechanism works. The Time Warp Simulator (TWSIM) subdirectory contains a sequential simulation engine that is interface compatible with TWOS. This means that an application designer and programmer who wish to use TWOS can prototype code on TWSIM on a single processor and/or workstation before having to deal with the complexity of working on a distributed system. TWSIM also provides statistics about the application which may be helpful for determining the correctness of an application and for achieving good performance on TWOS. Version 2.5.1 has an updated interface that is not compatible with 2.0. The program's user manual assists the simulation programmer in the design, coding, and implementation of discrete-event simulations running on TWOS. The manual also includes a practical user's guide to the TWOS application benchmark, Colliding Pucks. TWOS supports simulations written in the C programming language. It is designed

  19. Electrochemical degradation of 5-FU using a flow reactor with BDD electrode: Comparison of two electrochemical systems.

    PubMed

    Ochoa-Chavez, A S; Pieczyńska, A; Fiszka Borzyszkowska, A; Espinoza-Montero, P J; Siedlecka, E M

    2018-06-01

    In this study, the electrochemical degradation process of 5-fluorouracil (5-FU) in aqueous media was performed using a continuous flow reactor in an undivided cell (system I), and in a divided cell with a cationic membrane (Nafion ® 424) (system II). In system I, 75% of 5-FU degradation was achieved (50 mg L -1 ) with a applied current density j app  = 150 A m -2 , volumetric flow rate qv = 13 L h -1 , after 6 h of electrolysis (k app  = 0.004 min -1 ). The removal efficiency of 5-FU was higher (95%) when the concentration was 5 mg L -1 under the same conditions. Nitrates (22% of initial amount of N), fluorides (27%) and ammonium (10%) were quantified after 6 h of electrolysis. System II, 77% of 5-FU degradation was achieved (50 mg L -1 ) after 6 h of electrolysis (k app  = 0.004 min -1 ). The degradation rate of 5-FU was complete when the concentration was 5 mg L -1 under the same conditions. Nitrates (29% of initial amount of N), fluorides (25%) and ammonium (5%) were quantified after 6 h of electrolysis. In addition, the main organic byproducts identified by mass spectroscopy were aliphatic compound with carbonyl and carboxyl functionalities. Due to, the mineralization of 5-FU with acceptable efficiency of 88% found in system II (j app of 200 A m -2 ), this system seems to be more promising in the cytostatic drug removal. Moreover the efficiency of 5-FU removal in diluted solutions is better in system II than in system I. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Optogalvanic spectroscopy of the C"5Pi ui-A' 5Sigma+g electronic system of N2.

    PubMed

    Pirali, O; Tokaryk, D W

    2006-11-28

    We have recorded spectra involving the 3-1, 4-2, 2-0, and 2-2 bands of the C" 5Pi(ui)-A' (5)Sigma+(g) electronic system of N(2) using optogalvanic detection in a discharge through a supersonic jet expansion of argon mixed with a trace of nitrogen gas. The spectra have an effective rotational temperature of about 45 K. They involve all five spin-orbit components of the C" 5Pi(ui) state, which has allowed for precise determination of the spin-orbit coupling in this state. Analysis of the C" 5Pi(ui) state Lambda-doubling shows that it is caused primarily by a first-order spin-spin effect rather than by interaction with Sigma(u) (+/-) states. Our results allow us to assign lines in the 4-2 and 2-0 bands observed in a fluorescence depletion experiment conducted over ten years ago [Ch. Ottinger and A. F. Vilesov, J. Chem. Phys. 103, 9929 (1995)], and to comment on the suggestion that perturbations to the C (3)Pi(u) v=1 level of N(2) arise from interactions with the C" 5Pi(ui) state.

  1. 5.5nm wavelength-tunable high-power MOPA diode laser system at 971 nm

    NASA Astrophysics Data System (ADS)

    Tawfieq, Mahmoud; Müller, André; Fricke, Jörg; Della Casa, Pietro; Ressel, Peter; Ginolas, Arnim; Feise, David; Sumpf, Bernd; Tränkle, Günther

    2018-02-01

    In this work, a widely tunable hybrid master oscillator power amplifier (MOPA) diode laser with 6.2 W of output power at 971.8 nm will be presented. The MO is a DBR laser, with a micro heater embedded on top of the DBR grating for wavelength tunability. The emitted light of the MO is collimated and coupled into a tapered amplifier using micro cylindrical lenses, all constructed on a compact 25 mm × 25 mm conduction cooled laser package. The MOPA system emits light with a measured spectral width smaller than 17 pm, limited by the spectrometer, and with a beam propagation factor of M2 1/e2 = 1.3 in the slow axis. The emission is thus nearly diffraction limited with 79% of the total power within the central lobe (4.9 W diffraction limited). The electrically controlled micro-heater provides up to 5.5 nm of wavelength tunability, up to a wavelength of 977.3 nm, while maintaining an output power variation of only +/- 0.16 % for the entire tuning range.

  2. Surface Roughness and Gloss of Actual Composites as Polished With Different Polishing Systems.

    PubMed

    Rodrigues-Junior, S A; Chemin, P; Piaia, P P; Ferracane, J L

    2015-01-01

    This in vitro study evaluated the effect of polishing with different polishing systems on the surface roughness and gloss of commercial composites. One hundred disk-shaped specimens (10 mm in diameter × 2 mm thick) were made with Filtek P-90, Filtek Z350 XT, Opallis, and Grandio. The specimens were manually finished with #400 sandpaper and polished by a single operator using three multistep systems (Superfix, Diamond Pro, and Sof-lex), one two-step system (Polidores DFL), and one one-step system (Enhance), following the manufacturer's instructions. The average surface roughness (μm) was measured with a surface profilometer (TR 200 Surface Roughness Tester), and gloss was measured using a small-area glossmeter (Novo-Curve, Rhopoint Instrumentation, East Sussex, UK). Data were analyzed by two-way analysis of variance and Tukey's test (α=0.05). Statistically significant differences in surface roughness were identified by varying the polishing systems (p<0.0001) and by the interaction between polishing system and composite (p<0.0001). Pairwise comparisons revealed higher surface roughness for Grandio when polished with Sof-Lex and Filtek Z250 and Opallis when polished with Enhance. Gloss was influenced by the composites (p<0.0001), the polishing systems (p<0.0001), and the interaction between them (p<0.0001). The one-step system, Enhance, produced the lowest gloss for all composites. Surface roughness and gloss were affected by composites and polishing systems. The interaction between both also influenced these surface characteristics, meaning that a single polishing system will not behave similarly for all composites. The multistep systems produced higher gloss, while the one-step system produced the highest surface roughness and the lowest gloss of all.

  3. Influence of Chromium Doping on Electrical and Magnetic Behavior of Nd0.5Sr0.5MnO3 System

    NASA Astrophysics Data System (ADS)

    Lalitha, G.; Pavan Kumar, N.; Venugopal Reddy, P.

    2018-04-01

    With a view to understand the influence of chromium doping at the Mn site on the electrical and magnetic behavior of the Nd0.5Sr0.5MnO3 manganite system, a series of samples were prepared by the citrate sol-gel route method. The samples were characterized structurally by XRD. A systematic investigation of electrical resistivity over a temperature range 5-300 K was carried out mainly to understand the magneto-transport behavior in these materials. Studies on the variation of magnetization with temperature over a temperature range 80-330 K were undertaken. Investigation of magnetization at different magnetic fields at two different temperatures, viz. 80 and 300 K, was also carried out. The results show that chromium doping gave typical electrical and magnetic properties. It has been concluded that the coexistence of charge ordered and ferromagnetic phases induced by chromium doping plays an important role in the low-temperature behavior of the system.

  4. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Innov-X XT400 Series (XT400) x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XT400 analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XT400 analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was as

  5. 5 CFR 110.101 - What are OPM's Notice and Posting System responsibilities?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false What are OPM's Notice and Posting System... REGULATIONS POSTING NOTICES OF NEW OPM REGULATIONS § 110.101 What are OPM's Notice and Posting System... review. (b) A copy of the notice of rulemaking that appears in the Federal Register or a link to a Web...

  6. Neuromodulation of reciprocal glutamatergic inhibition between antagonistic motoneurons by 5-hydroxytryptamine (5-HT) in crayfish walking system.

    PubMed

    Pearlstein, E; Clarac, F; Cattaert, D

    1998-01-23

    In an in vitro preparation of the crayfish thoracic locomotor system, paired intracellular recordings were performed from antagonistic depressor (Dep) and levator (Lev) motoneurons (MNs) that control the second joint of walking legs. Connections between these two groups of MNs consist mainly of inhibitory connections and weak electrotonic synapses. Injection of depolarizing current into a Lev MN results in a hyperpolarization in a Dep MN, and vice versa. This reciprocal glutamatergic inhibition, is not changed in the presence of the sodium channel blocker tetrodotoxin (TTX) and therefore is likely supported by a direct connection between MNs. By contrast, reciprocal inhibition is largely reduced in the presence of 5-hydroxytryptamine (5-HT; 10 microM). Direct micro-application of glutamate pressure-ejected close to an intracellularly recorded MN, evoked an inhibitory response in that MN, accompanied by a decrease of input resistance. These two effects were dramatically reduced in the presence of 5-HT. Thus 5-HT could be involved in mechanisms of dynamic reconfigurations of the neural network controlling leg movements in crayfish.

  7. A simple 5-DoF MR-compatible motion signal measurement system.

    PubMed

    Chung, Soon-Cheol; Kim, Hyung-Sik; Yang, Jae-Woong; Lee, Su-Jeong; Choi, Mi-Hyun; Kim, Ji-Hye; Yeon, Hong-Won; Park, Jang-Yeon; Yi, Jeong-Han; Tack, Gye-Rae

    2011-09-01

    The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were located in a shielded case, which was made of copper and aluminum. The motion signal was modulated to an optic signal using pulse width modulation, and the modulated optic signal was transmitted outside the MR shield room using a high-intensity light-emitting diode and an optic cable. The motion signal was recorded on a PC by demodulating the transmitted optic signal into an electric signal. Various kinematic variables, such as angle, acceleration, velocity, and jerk, can be measured or calculated by using the motion measurement system developed here. This system also enables motion tracking by extracting the position information from the motion signals. It was verified that MR images and motion signals could reliably be measured simultaneously.

  8. PM2.5 monitoring system based on ZigBee wireless sensor network

    NASA Astrophysics Data System (ADS)

    Lin, Lukai; Li, Xiangshun; Gu, Weiying

    2017-06-01

    In the view of the haze problem, aiming at improving the deficiency of the traditional PM2.5 monitoring methods, such as the insufficient real-time monitoring, limited transmission distance, high cost and the difficulty to maintain, the atmosphere PM2.5 monitoring system based on ZigBee technology is designed. The system combines the advantages of ZigBee’s low cost, low power consumption, high reliability and GPRS/Internet’s capability of remote transmission of data. Furthermore, it adopts TI’s Z-Stack protocol stack, and selects CC2530 chip and TI’s MSP430 microcontroller as the core, which establishes the air pollution monitoring network that is helpful for the early prediction of major air pollution disasters.

  9. Effect of Energy Drinks on Discoloration of Silorane and Dimethacrylate-Based Composite Resins.

    PubMed

    Ahmadizenouz, Ghazaleh; Esmaeili, Behnaz; Ahangari, Zohreh; Khafri, Soraya; Rahmani, Aghil

    2016-08-01

    This study aimed to assess the effects of two energy drinks on color change (ΔE) of two methacrylate-based and a silorane-based composite resin after one week and one month. Thirty cubic samples were fabricated from Filtek P90, Filtek Z250 and Filtek Z350XT composite resins. All the specimens were stored in distilled water at 37°C for 24 hours. Baseline color values (L*a*b*) of each specimen were measured using a spectrophotometer according to the CIEL*a*b* color system. Ten randomly selected specimens from each composite were then immersed in the two energy drinks (Hype, Red Bull) and artificial saliva (control) for one week and one month. Color was re-assessed after each storage period and ΔE values were calculated. The data were analyzed using the Kruskal Wallis and Mann-Whitney U tests. Filtek Z250 composite showed the highest ΔE irrespective of the solutions at both time points. After seven days and one month, the lowest ΔE values were observed in Filtek Z350XT and Filtek P90 composites immersed in artificial saliva, respectively. The ΔE values of Filtek Z250 and Z350XT composites induced by Red Bull and Hype energy drinks were not significantly different. Discoloration of Filtek P90 was higher in Red Bull energy drink at both time points. Prolonged immersion time in all three solutions increased ΔE values of all composites. However, the ΔE values were within the clinically acceptable range (<3.3) at both time points.

  10. Air Quality Modeling Using the NASA GEOS-5 Multispecies Data Assimilation System

    NASA Technical Reports Server (NTRS)

    Keller, Christoph A.; Pawson, Steven; Wargan, Krzysztof; Weir, Brad

    2018-01-01

    The NASA Goddard Earth Observing System (GEOS) data assimilation system (DAS) has been expanded to include chemically reactive tropospheric trace gases including ozone (O3), nitrogen dioxide (NO2), and carbon monoxide (CO). This system combines model analyses from the GEOS-5 model with detailed atmospheric chemistry and observations from MLS (O3), OMI (O3 and NO2), and MOPITT (CO). We show results from a variety of assimilation test experiments, highlighting the improvements in the representation of model species concentrations by up to 50% compared to an assimilation-free control experiment. Taking into account the rapid chemical cycling of NO2 when applying the assimilation increments greatly improves assimilation skills for NO2 and provides large benefits for model concentrations near the surface. Analysis of the geospatial distribution of the assimilation increments suggest that the free-running model overestimates biomass burning emissions but underestimates lightning NOx emissions by 5-20%. We discuss the capability of the chemical data assimilation system to improve atmospheric composition forecasts through improved initial value and boundary condition inputs, particularly during air pollution events. We find that the current assimilation system meaningfully improves short-term forecasts (1-3 day). For longer-term forecasts more emphasis on updating the emissions instead of initial concentration fields is needed.

  11. Time-Reversal Based Range Extension Technique for Ultra-Wideband (UWB) Sensors and Applications in Tactical Communications and Networking

    DTIC Science & Technology

    2008-10-16

    signal from the signal generator is also used to synchronize DSO to record the data of the received signal. The tapped -delay-line model of CIR will...between each filter tap . The output y(t) — h(t) *x(t) is then uniformly sampled with sampling period Ts. 1 ’s follows the relation Ta/Th — q, where q... eft ) ProbtagPake ^ p(l> ’HO PriHretuHg Figure 5.5: An equivalent block diagram of channel estimation The success of recovery relies on the

  12. Evaluation of 5 different labeled polymer immunohistochemical detection systems.

    PubMed

    Skaland, Ivar; Nordhus, Marit; Gudlaugsson, Einar; Klos, Jan; Kjellevold, Kjell H; Janssen, Emiel A M; Baak, Jan P A

    2010-01-01

    Immunohistochemical staining is important for diagnosis and therapeutic decision making but the results may vary when different detection systems are used. To analyze this, 5 different labeled polymer immunohistochemical detection systems, REAL EnVision, EnVision Flex, EnVision Flex+ (Dako, Glostrup, Denmark), NovoLink (Novocastra Laboratories Ltd, Newcastle Upon Tyne, UK) and UltraVision ONE (Thermo Fisher Scientific, Fremont, CA) were tested using 12 different, widely used mouse and rabbit primary antibodies, detecting nuclear, cytoplasmic, and membrane antigens. Serial sections of multitissue blocks containing 4% formaldehyde fixed paraffin embedded material were selected for their weak, moderate, and strong staining for each antibody. Specificity and sensitivity were evaluated by subjective scoring and digital image analysis. At optimal primary antibody dilution, digital image analysis showed that EnVision Flex+ was the most sensitive system (P < 0.005), with means of 8.3, 13.4, 20.2, and 41.8 gray scale values stronger staining than REAL EnVision, EnVision Flex, NovoLink, and UltraVision ONE, respectively. NovoLink was the second most sensitive system for mouse antibodies, but showed low sensitivity for rabbit antibodies. Due to low sensitivity, 2 cases with UltraVision ONE and 1 case with NovoLink stained false negatively. None of the detection systems showed any distinct false positivity, but UltraVision ONE and NovoLink consistently showed weak background staining both in negative controls and at optimal primary antibody dilution. We conclude that there are significant differences in sensitivity, specificity, costs, and total assay time in the immunohistochemical detection systems currently in use.

  13. 5 CFR 430.204 - Agency performance appraisal system(s).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Other Employees § 430.204 Agency performance appraisal system(s). (a) Each agency as defined at section... employees covered by this subpart. (b) An agency appraisal system shall establish agencywide policies and... covered by the system. At a minimum, an agency system shall— (1) Provide for— (i) Establishing employee...

  14. 5 CFR 430.204 - Agency performance appraisal system(s).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Other Employees § 430.204 Agency performance appraisal system(s). (a) Each agency as defined at section... employees covered by this subpart. (b) An agency appraisal system shall establish agencywide policies and... covered by the system. At a minimum, an agency system shall— (1) Provide for— (i) Establishing employee...

  15. 5 CFR 430.204 - Agency performance appraisal system(s).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Other Employees § 430.204 Agency performance appraisal system(s). (a) Each agency as defined at section... employees covered by this subpart. (b) An agency appraisal system shall establish agencywide policies and... covered by the system. At a minimum, an agency system shall— (1) Provide for— (i) Establishing employee...

  16. 5 CFR 430.204 - Agency performance appraisal system(s).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Other Employees § 430.204 Agency performance appraisal system(s). (a) Each agency as defined at section... employees covered by this subpart. (b) An agency appraisal system shall establish agencywide policies and... covered by the system. At a minimum, an agency system shall— (1) Provide for— (i) Establishing employee...

  17. HTML 5 Displays for On-Board Flight Systems

    NASA Technical Reports Server (NTRS)

    Silva, Chandika

    2016-01-01

    During my Internship at NASA in the summer of 2016, I was assigned to a project which dealt with developing a web-server that would display telemetry and other system data using HTML 5, JavaScript, and CSS. By doing this, it would be possible to view the data across a variety of screen sizes, and establish a standard that could be used to simplify communication and software development between NASA and other countries. Utilizing a web- approach allowed us to add in more functionality, as well as make the displays more aesthetically pleasing for the users. When I was assigned to this project my main task was to first establish communication with the current display server. This display server would output data from the on-board systems in XML format. Once communication was established I was then asked to create a dynamic telemetry table web page that would update its header and change as new information came in. After this was completed, certain minor functionalities were added to the table such as a hide column and filter by system option. This was more for the purpose of making the table more useful for the users, as they can now filter and view relevant data. Finally my last task was to create a graphical system display for all the systems on the space craft. This was by far the most challenging part of my internship as finding a JavaScript library that was both free and contained useful functions to assist me in my task was difficult. In the end I was able to use the JointJs library and accomplish the task. With the help of my mentor and the HIVE lab team, we were able to establish stable communication with the display server. We also succeeded in creating a fully dynamic telemetry table and in developing a graphical system display for the advanced modular power system. Working in JSC for this internship has taught me a lot about coding in JavaScript and HTML 5. I was also introduced to the concept of developing software as a team, and exposed to the different

  18. 24 CFR 5.233 - Mandated use of HUD's Enterprise Income Verification (EIV) System.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Mandated use of HUD's Enterprise Income Verification (EIV) System. 5.233 Section 5.233 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Disclosure...

  19. Effects of self-etching primer on shear bond strength of orthodontic brackets at different debond times.

    PubMed

    Turk, Tamer; Elekdag-Turk, Selma; Isci, Devrim

    2007-01-01

    To evaluate the effect of a self-etching primer on shear bond strengths (SBS) at the different debond times of 5, 15, 30, and 60 minutes and 24 hours. Brackets were bonded to human premolars with different etching protocols. In the control group (conventional method [CM]) teeth were etched with 37% phosphoric acid. In the study group, a self-etching primer (SEP; Transbond Plus Self Etching Primer; 3M Unitek, Monrovia, Calif) was applied as recommended by the manufacturer. Brackets were bonded with light-cure adhesive paste (Transbond XT; 3M Unitek) and light-cured for 20 seconds in both groups. The shear bond test was performed at the different debond times of 5, 15, 30 and 60 minutes and 24 hours. Lowest SBS was attained with a debond time of 5 minutes for the CM group (9.51 MPa) and the SEP group (8.97 MPa). Highest SBS was obtained with a debond time of 24 hours for the CM group (16.82 MPa) and the SEP group (19.11 MPa). Statistically significant differences between the two groups were not observed for debond times of 5, 15, 30, or 60 minutes. However, the SBS values obtained at 24 hours were significantly different (P < .001). Adequate SBS was obtained with self-etching primer during the first 60 minutes (5, 15, 30 and 60 minutes) when compared with the conventional method. It is reliable to load the bracket 5 minutes after bonding using self-etching primer (Transbond Plus) with the light-cure adhesive (Transbond XT).

  20. Evaluation of a Constrained Facet Analysis Efficiency Model for Identifying the Efficiency of Medical Treatment Facilities in the Army Medical Department

    DTIC Science & Technology

    1990-07-31

    examples on their use is available with the PASS User Documentation Manual. 2 The data structure of PASS requires a three- lvel organizational...files, and missing control variables. A specific problem noted involved the absence of 8087 mathematical co-processor on the target IBM-XT 21 machine...System, required an operational understanding of the advanced mathematical technique used in the model. Problems with the original release of the PASS