Sample records for yag crystal investigated

  1. Study of structural and optical properties of YAG and Nd:YAG single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kostić, S.; Lazarević, Z.Ž., E-mail: lzorica@yahoo.com; Radojević, V.

    2015-03-15

    Highlights: • Transparent YAG and pale pink Nd:YAG single crystals were produced by the Czochralski technique. • Growth mechanisms and shape of the liquid/solid interface and incorporation of Nd{sup 3+} were studied. • The structure of the crystals was investigated by X-ray diffraction, Raman and IR spectroscopy. • The 15 Raman and 17 IR modes were observed. • The obtained YAG and Nd:YAG single crystals were without core and of good optical quality. - Abstract: Yttrium aluminum garnet (YAG, Y{sub 3}Al{sub 5}O{sub 12}) and yttrium aluminum garnet doped with neodymium (Nd:YAG) single crystals were grown by the Czochralski technique. Themore » critical diameter and the critical rate of rotation were calculated. Suitable polishing and etching solutions were determined. As a result of our experiments, the transparent YAG and pale pink Nd:YAG single crystals were produced. The obtained crystals were studied by X-ray diffraction, Raman and IR spectroscopy. The crystal structure was confirmed by XRD. The 15 Raman and 17 IR modes were observed. The Raman and IR spectroscopy results are in accordance with X-ray diffraction analysis. The obtained YAG and Nd:YAG single crystals were without core and of good optical quality. The absence of a core was confirmed by viewing polished crystal slices. Also, it is important to emphasize that the obtained Nd:YAG single crystal has a concentration of 0.8 wt.% Nd{sup 3+} that is characteristic for laser materials.« less

  2. Microchip laser based on Yb:YAG/V:YAG monolith crystal

    NASA Astrophysics Data System (ADS)

    Nejezchleb, Karel; Šulc, Jan; Jelínková, Helena; Škoda, Václav

    2016-03-01

    V:YAG crystal was investigated as a passive Q-switch of longitudinally diode-pumped microchip laser, emitting radiation at wavelength 1030.5 nm. This laser was based on diffusion bonded monolith crystal (diameter 3 mm) which combines in one piece an active laser part (Yb:YAG crystal, 10 at.% Yb/Y, 3 mm long) and saturable absorber (V:YAG crystal, 2 mm long, initial transmission 86 % @ 1031 nm). The microchip resonator consisted of dielectric mirrors directly deposited on the monolith surfaces (pump mirror HT @ 968 nm and HR @ 1031 nm on Yb:YAG part, output coupler with reflection 55 % @ 1031 nm on the V:YAG part). For longitudinal CW pumping of Yb:YAG part, a fibre coupled (core diameter 100 μm, NA = 0.22, emission @ 968 nm) laser diode was used. The laser threshold was 3.8W. The laser slope efficiency for output mean in respect to incident pumping was 16 %. The linearly polarized generated transversal intensity beam profile was close to the fundamental Gaussian mode. The generated pulse length, stable and mostly independent on pumping power, was equal to 1.3 ns (FWHM). The single pulse energy was increasing with the pumping power and for the maximum pumping 9.7W it was 78 μJ which corresponds to the pulse peak-power 56 kW. The maximum Yb:YAG/V:YAG microchip laser mean output power of 1W was reached without observable thermal roll-over. The corresponding Q-switched pulses repetition rate was 13.1 kHz.

  3. Growth and luminescent properties of Yb:YAG and Ca co-doped Yb:YAG ultrafast scintillation crystals

    NASA Astrophysics Data System (ADS)

    Zhu, Maodong; Qi, Hongji; Pan, Mingyan; Hou, Qing; Jiang, Benxue; Jin, Yaxue; Han, Hetong; Song, Zhaohui; Zhang, Hui

    2018-05-01

    In this work, Yb-doped Y3Al5O12 [yttrium aluminum garnet (YAG)] crystals and Ca co-doped Yb:YAG crystals were grown by the Czochralski (CZ) method. The chemical formulas of the two crystals are (Yb0.1Y0.9)3Al5O12 and (Ca0.001Yb0.1Y0.899)3Al5O12, respectively. The structural, optical and luminescent properties of the Yb:YAG and Ca, Yb:YAG crystals were investigated by X-ray rocking curve, X-ray diffraction, Raman spectra, UV-Visble-NIR absorption spectra and X-ray fluorescence. X-ray fluorescence spectrum with two emission peaks at 330 nm and 490 nm were observed in the two kinds of crystals, which would increase slightly after the annealing. Comparing to the Yb:YAG crystal, Ca co-doped Yb:YAG crystal behaved the better luminescent intensity without changing the crystal structure and vibrational modes. This indicates that by doping Ca2+ in Yb:YAG crystal may be an appropriate way to enhance the luminescent property of the scintillation crystal.

  4. Enhanced performance of Cr,Yb:YAG microchip laser by bonding Yb:YAG crystal.

    PubMed

    Cheng, Ying; Dong, Jun; Ren, Yingying

    2012-10-22

    Highly efficient, laser-diode pumped Yb:YAG/Cr,Yb:YAG self-Q-switched microchip lasers by bonding Yb:YAG crystal have been demonstrated for the first time to our best knowledge. The effect of transmission of output coupler (T(oc)) on the enhanced performance of Yb:YAG/Cr,Yb:YAG microchip lasers has been investigated and found that the best laser performance was achieved with T(oc) = 50%. Slope efficiency of over 38% was achieved. Average output power of 0.8 W was obtained at absorbed pump power of 2.5 W; corresponding optical-to-optical efficiency of 32% was obtained. Laser pulses with pulse width of 1.68 ns, pulse energy of 12.4 μJ, and peak power of 7.4 kW were obtained. The lasers oscillated in multi-longitudinal modes. The wide separation of longitudinal modes was attributed to the mode selection by combined etalon effect of Cr,Yb:YAG, Yb:YAG thin plates and output coupler. Stable periodical pulse trains at different pump power levels have been observed owing to the longitudinal modes coupling and competition.

  5. Control of optical properties of YAG crystals by thermal annealing

    NASA Astrophysics Data System (ADS)

    Tkachenko, S.; Arhipov, P.; Gerasymov, I.; Kurtsev, D.; Vasyukov, S.; Nesterkina, V.; Shiran, N.; Mateichenko, P.; Sidletskiy, O.

    2018-02-01

    Optical properties of YAG crystals grown and annealed under different atmosphere conditions have been compared. Simultaneously we have registered the surface composition of crystals and content of basic admixtures in the crystals grown under the reducing conditions. Unlike YAG grown under weakly oxidizing conditions in Ir crucibles and bleached under oxidizing annealing, YAGMo crystals grown in Mo crucibles under reducing Ar + CO atmosphere can be bleached by both oxidizing and reducing thermal annealing. The bleaching of YAGMo is not reversed by further annealing under any available conditions. Mechanisms of this phenomenon have been discussed, including a possible role of admixtures in elimination of color centers in YAG grown under the reducing conditions.

  6. Resonantly diode-pumped eye-safe Er:YAG laser with fiber-shaped crystal

    NASA Astrophysics Data System (ADS)

    Němec, Michal; Šulc, Jan; Hlinomaz, Kryštof; Jelínková, Helena; Nejezchleb, Karel; Čech, Miroslav

    2018-02-01

    Solid-state eye-safe lasers are interesting sources for various applications, such as lidar, remote sensing, and ranging. A resonantly diode-pumped Er:YAG laser could be one of them allowing to reach a tunable laser emission in 1.6 μm spectral region. To overcome low pump absorption and poor pumping beam quality generated by commercially available laser diode, an active medium could be formed to long and thin laser rod guiding pumping radiation. Such an effective cooling during a high power pumping, which is a "crystal-fiber" benefit, may be useful for "standard" crystal active medium. The main goal of this work was to investigate the laser characteristics of new developed Er:YAG crystal with a special shape for diode-pumping. Er:YAG fiber-shape crystal with square cross-section (1x1mm) and 40mm in length was doped by 0.1% Er3+ ions. All sides of this crystal were polished and in addition the end-faces of it were antireflection coatings for the wavelength 1470 and 1645 nm. As a pump system, a fiber coupled laser diode (f = 10 Hz, t = 10 ms) emitting radiation at 1465 nm wavelength was used. Er:YAG fiber-shape crystal was placed onto a copper holder in the 85 mm long plan-concave resonator consisting of a pump flat mirror and output curved (r = 150 mm) coupler with a reflectivity of 96 % @ 1645 nm. The dependence of the output peak power on absorbed pump power was investigated and the maximum 0.8 W was obtained. The corresponding slope efficiency was 14.5 %. The emitting wavelength was equaled to 1645 nm (4 nm linewidth, FWHM). The spatial beam structure was close to the Gaussian mode.

  7. Erbium Distribution in Single Crystal YAG Fibers Grown by Laser-Heated Pedestal Growth Technique

    DTIC Science & Technology

    2015-08-28

    single crystal YAG fibers grown by laser - heated pedestal growth technique Single crystal (SC) yttrium aluminum garnet (YAG, Y3Al5O12) as a host...inserted into a SC YAG tube. This rod-in-tube was used as a preform in our laser -heated pedestal growth (LHPG) apparatus to grow a fiber with a radial...fibers grown by laser -heated pedestal growth technique Report Title Single crystal (SC) yttrium aluminum garnet (YAG, Y3Al5O12) as a host material has

  8. Growth of single-crystal YAG fiber optics.

    PubMed

    Nie, Craig D; Bera, Subhabrata; Harrington, James A

    2016-07-11

    Single-crystal YAG (Y3Al5O12) fibers have been grown by the laser heated pedestal growth technique with losses as low as 0.3 dB/m at 1.06 μm. These YAG fibers are as long as about 60 cm with diameters around 330 μm. The early fibers were grown from unoriented YAG seed fibers and these fibers exhibited facet steps or ridges on the surface of the fiber. However, recently we have grown fibers using an oriented seed to grow step-free fibers. Scattering losses made on the fibers indicate that the scattering losses are equal to about 30% of the total loss.

  9. Pump beam waist-dependent pulse energy generation in Nd:YAG/Cr4+:YAG passively Q-switched microchip laser

    NASA Astrophysics Data System (ADS)

    Li, Chao-yu; Dong, Jun

    2016-08-01

    The incident pump beam waist-dependent pulse energy generation in Nd:YAG/Cr4+:YAG composite crystal passively Q-switched microchip laser has been investigated experimentally and theoretically by moving the Nd:YAG/Cr4+:YAG composite crystal along the pump beam direction. Highest pulse energy of 0.4 mJ has been generated when the Nd:YAG/Cr4+:YAG composite crystal is moved about 6 mm away from the focused pump beam waist. Laser pulses with pulse width of 1.7 ns and peak power of over 235 kW have been achieved. The theoretically calculated effective laser beam area at different positions of Nd:YAG/Cr4+:YAG composite crystal along the pump beam direction is in good agreement with the experimental results. The highest peak power can be generated by adjusting the pump beam waist incident on the Nd:YAG/Cr4+:YAG composite crystal to optimize the effective laser beam area in passively Q-switched microchip laser.

  10. Spectroscopic investigation of the Cr to Tm energy transfer in Yttrium Aluminum Garnet (YAG) crystals

    NASA Technical Reports Server (NTRS)

    Dibartolo, B.

    1988-01-01

    New and interesting schemes have recently been considered for the efficient operation of solid-state ionic laser systems. Often the available data on these systems were obtained only because they seemed directly related to the laser performance and provide no insight into the physical processes. A more systematic approach is desirable, where more attention is devoted to the elementary basic processes and to the nature of the mechanisms at work. It is with this aim that we have undertaken the present study. Yttrium Aluminum Garnet (Y4Al5O12), called YAG, has two desirable properties as host for rare earth impurities: (1) trivalent rare earth ions can replace the yttrium without any charge compensation problem, and (2) YAG crystals have high cutoff energies. The results of measurements and calculations indicate that the Cr(3+) ion in YAG can be used to sensitize efficiently the Tm(3+) ion.

  11. Kinetics and pathways for crystallization of amorphous mullite and YAG

    NASA Astrophysics Data System (ADS)

    Johnson, Bradley Richard

    The crystallization behavior of quenched mullite (3Al2O 3•2SiO2) and YAG (Y3Al5O 12) composition glasses (made using containerless methods) were characterized with the ultimate goal of producing single crystal, structural, ceramic oxide fibers from these materials. The kinetics for crystallization were determined from thermal analysis experiments. From the results, time-temperature-transformation (TTT) curves were calculated. The crystallization pathways were determined by examining the crystal structure, microstructure, and chemical composition of heat treated specimens using x-ray diffraction (XRD), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). A machine was also designed and built to facilitate controlled crystallization of amorphous fibers. Quenched, Y3Al5O12 composition beads crystallized at temperatures as low as 840°C. The as-received specimens contained a few, small YAG crystals, in addition to a mixture of different amorphous phases. The coexistence of two different amorphous phases of the same composition, but having different densities is termed polyamorphism, and this has been reported to occur in Y3Al5O12 composition quenched melts. Although various crystallization pathways have been reported for chemically synthesized YAG precursors, these specimens crystallized directly into YAG, which was the only phase formed. Quenched, 3Al2O3•2SiO2 composition mullite beads and fibers crystallized at temperatures as low as 920°C. Due to phase separation in the quenched melts, multiple phases with slightly different compositions and different crystallization activation energies crystallized. These phases were not equilibrium, 3:2 mullite, but metastable, alumina-rich, pseudotetragonal mullite. The residual, amorphous, silica-rich phase existed as numerous, 7--10 nm sized inclusions embedded within pseudotetragonal mullite. A large amount of internal strain was detected in pseudotetragonal mullite, and the source of this

  12. Study on growth techniques and macro defects of large-size Nd:YAG laser crystal

    NASA Astrophysics Data System (ADS)

    Quan, Jiliang; Yang, Xin; Yang, Mingming; Ma, Decai; Huang, Jinqiang; Zhu, Yunzhong; Wang, Biao

    2018-02-01

    Large-size neodymium-doped yttrium aluminum garnet (Nd:YAG) single crystals were grown by the Czochralski method. The extinction ratio and wavefront distortion of the crystal were tested to determine the optical homogeneity. Moreover, under different growth conditions, the macro defects of inclusion, striations, and cracking in the as-grown Nd:YAG crystals were analyzed. Specifically, the inclusion defects were characterized using scanning electron microscopy and energy dispersive spectroscopy. The stresses of growth striations and cracking were studied via a parallel plane polariscope. These results demonstrate that improper growth parameters and temperature fields can enhance defects significantly. Thus, by adjusting the growth parameters and optimizing the thermal environment, high-optical-quality Nd:YAG crystals with a diameter of 80 mm and a total length of 400 mm have been obtained successfully.

  13. Investigations of YAG:Er(3+),Yb(3+) and YAG:Co(2+) Crystals for Laser Applications

    DTIC Science & Technology

    2001-01-01

    incident laser radiation wavelength of 1535 nm obtained for YAG:Co2÷ sample of initial transmission of 24.9%. As it can be seen from the presented...longitudinally pumped microlasers generating at 1535 tnm made of YAG:Er3 + ,Ylb3 + were carried out. A schematic of the laser cavity is shown in Fig. 4. The...I 17, Bellingham, Washington, 1995. 3. R. Fluck, U. Keller, E. Gini, H. Melchior, Eyesafe pulsed microchip laser , OSA TOPS Advanced Solid State

  14. Influence of temperature on Yb:YAG/Cr:YAG microchip laser operation

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Eisenschreiber, Jan; Jelínková, Helena; Nejezchleb, Karel; Å koda, Václav

    2017-02-01

    The goal of this work was an investigation of the temperature influence (in range from 80 up to 320 K) on the laser properties of Yb:YAG/Cr:YAG Q-switched diode-pumped microchip laser. This laser was based on monolith crystal (diameter 3mm) which combines in one piece an active laser part (Yb:YAG crystal, 10 at.% Yb/Y, 3mm long) and saturable absorber (Cr:YAG crystal, 1.36mm long, initial transmission 90% @ 1031 nm). The laser resonator pump mirror (HT for pump radiation, HR for generated radiation) was directly deposited on the Yb:YAG monolith part. The output coupler with reflection 55% for the generated wavelength was placed on the Cr:YAG part. The microchip laser was placed in the temperature controlled cupreous holder inside vacuum chamber of the liquid nitrogen cryostat. For Yb:YAG part longitudinal pulsed pumping (pumping pulse length 2.5 ms, rep-rate 20 Hz, power amplitude 21W) a fibre coupled (core diameter 400 μm, NA= 0:22) laser diode, operating at wavelength 933 nm, was used. The microchip laser mean output power, pulse duration, repetition rate, emission wavelength, and laser beam profile were measured in dependence on temperature. The generated pulse length was in range from 2.2 ns to 1.1 ns (FWHM) with the minimum at 230 K. The single pulse energy was peaking (0.4 mJ) at 180 K. The highest peak power (325 kW) was obtained at 220 K. The highest pulse repetition rate (38 kHz) and output mean power (370mW) was reached for temperature 80 K.

  15. Coilable single crystal fibers of doped-YAG for high power laser applications

    NASA Astrophysics Data System (ADS)

    Maxwell, Gisele; Soleimani, Nazila; Ponting, Bennett; Gebremichael, Eminet

    2013-05-01

    Single crystal fibers are an intermediate between laser crystals and doped glass fibers. They can combine the advantages of both by guiding laser light and matching the efficiencies found in bulk crystals, making them ideal candidates for high-power laser and fiber laser applications. In particular, a very interesting feature of single crystal fiber is that they can generate high power in the eye-safe range (Er:YAG) with a high efficiency, opening new possibilities for portable directed energy weapons. This work focuses on the growth of a flexible fiber with a core of dopant (Er, Nd, Yb, etc…) that will exhibit good waveguiding properties. Direct growth or a combination of growth and cladding experiments are described. We have, to date, demonstrated the growth of a flexible foot long 45 microns doped YAG fiber. Scattering loss measurements at visible wavelengths along with dopant profile characterization are also presented. Laser characterization for these fibers is in progress.

  16. Laser-induced damage of coatings on Yb:YAG crystals at cryogenic condition

    NASA Astrophysics Data System (ADS)

    Wang, He; Zhang, Weili; Chen, Shunli; Zhu, Meiping; He, Hongbo; Fan, Zhengxiu

    2011-12-01

    As large amounts of heat need to be dissipated during laser operation, some diode pumped solid state lasers (DPSSL), especially Yb:YAG laser, operate at cryogenic condition. This work investigated the laser induced damage of coatings (high-reflective and anti-reflective coatings) on Yb:YAG crystals at cryogenic temperature and room temperature. The results show that the damage threshold of coatings at cryogenic temperature is lower than the one at room temperature. Field-emission scanning electron microscopy (FESEM), optical profiler, step profiler and Atomic force microscope (AFM) were used to obtain the damage morphology, size and depth. Taking alteration of physical parameters, microstructure of coatings and the environmental pollution into consideration, we analyzed the key factor of lowering the coating damage threshold at cryogenic conditions. The results are important to understand the mechanisms leading to damage at cryogenic condition.

  17. Growth and lasing of single crystal YAG fibers with different Ho3+ concentrations

    NASA Astrophysics Data System (ADS)

    Bera, Subhabrata; Nie, Craig D.; Soskind, Michael G.; Li, Yuan; Harrington, James A.; Johnson, Eric G.

    2018-01-01

    A method to grow single crystal (SC) yttrium aluminum garnet (YAG) fibers with varied rare-earth ion dopant concentration has been proposed. Crystalline holmium aluminum garnet (HoAG), prepared via sol-gel process, was dip-coated on to previously grown SC YAG fibers. The HoAG coated SC YAG fiber preforms were re-grown to a smaller diameter using the laser heated pedestal growth (LHPG) technique. The final dopant concentration of the re-grown SC fiber was varied by changing the number of HoAG coatings on the preform. 120 μm diameter SC Ho:YAG fibers with four different dopant concentrations were grown. Lasing was demonstrated at 2.09 μm for these fibers. A maximum of 58.5% optical-to-optical slope efficiency was obtained.

  18. Femtosecond laser irradiation on Nd:YAG crystal: Surface ablation and high-spatial-frequency nanograting

    NASA Astrophysics Data System (ADS)

    Ren, Yingying; Zhang, Limu; Romero, Carolina; Vázquez de Aldana, Javier R.; Chen, Feng

    2018-05-01

    In this work, we systematically study the surface modifications of femtosecond (fs) laser irradiated Nd:YAG crystal in stationary focusing case (i.e., the beam focused on the target in the steady focusing geometry) or dynamic scanning case (i.e., focused fs-laser beam scanning over the target material). Micro-sized structures (e.g. micro-craters or lines) are experimentally produced in a large scale of parameters in terms of pulse energy as well as (effective) pulse number. Surface ablation of Nd:YAG surface under both processing cases are investigated, involving the morphological evolution, parameter dependence, the ablation threshold fluences and the incubation factors. Meanwhile, under specific irradiation conditions, periodic surface structures with high-spatial-frequency (<λ/2) can be generated. The obtained period is as short as 157 nm in this work. Investigations on the evolution of nanograting formation and fluence dependence of period are performed. The experimental results obtained under different cases and the comparison between them reveal that incubation effect plays an important role not only in the ablation of Nd:YAG surface but also in the processes of nanograting formation.

  19. A spatio-spectral polarization analysis of 1 µm-pumped bulk supercontinuum in a cubic crystal (YAG)

    NASA Astrophysics Data System (ADS)

    Choudhuri, Aradhana; Chatterjee, Gourab; Zheng, Jiaan; Hartl, Ingmar; Ruehl, Axel; Dwayne Miller, R. J.

    2018-06-01

    We present the first systematic study of the spatio-spectral polarization properties of a supercontinuum generated in a cubic crystal, yttrium-aluminum garnet (YAG), including a full spectral analysis of the white light core and surrounding ring structure. We observe no depolarization of the supercontinuum, and no spatial dependence of polarization ratios for any wavelength. We discuss the discrepancy of YAG's polarization behavior in the context of well-established results in literature reporting self-induced depolarization in other cubic crystals.

  20. Sensitivity-enhanced Tm3+/Yb3+ co-doped YAG single crystal optical fiber thermometry based on upconversion emissions

    NASA Astrophysics Data System (ADS)

    Yu, Lu; Ye, Linhua; Bao, Renjie; Zhang, Xianwei; Wang, Li-Gang

    2018-03-01

    Optical thermometry based on Y3Al5O12 (YAG) single crystal optical fiber with end Tm3+/Yb3+ co-doped is presented. The YAG crystal fiber with end Tm3+/Yb3+ co-doped was grown by laser heated pedestal growth (LHPG) method. Under a 976 nm laser diode excitation, the upconversion (UC) emissions, originating from 3F2,3 →3H6 and 3H4 →3H6 transitions of Tm3+ ions, were investigated in the temperature range from 333 K to 733 K. Interestingly, the UC emission intensity of 3F2,3 →3H6 transition was significantly enhanced with increase of temperature, as compared with the other Tm3+/Yb3+ co-doped materials. The temperature dependence of fluorescence intensity ratio (FIR) of these two emission bands (3F2,3/3H4 →3H6) suggests that this doped YAG crystal fiber can be used as a highly sensitive optical thermal probe, which demonstrates a high absolute sensitivity with the maximum value of 0.021 K-1 at 733 K. In addition, due to the compact structure, strong mechanical strength and high thermal stability, such thermal probe may be a more promising candidate for temperature sensor with a high spatial resolution.

  1. 10J water-cooled DPSSL system based on Yb:YAG crystal edge-cladded by Cr:YAG ceramics (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zheng, Jian-Gang; Yan, Xiongwei; Jiang, Xinying; Wang, Zhenguo; Li, Mingzhong; Zhang, Jun; Zhu, Qihua; Zheng, Wanguo

    2017-05-01

    Laser Inertial Fusion Energy (IFE) has been attracting the interests of the researchers around the world, because of the promising to the future energy. The Yb:YAG was broadly used in the research field of high-peak power and large energy laser with repetition-rate for IFE because of its outstanding performance, including significant thermal and mechanical capacities, long upper energy level lifetime, high quantum efficiency and highly doping capacity. But it exhibits high saturation fluence at room temperature because of the small emission and absorption cross-section. And at the same time this gain material exhibits self-absorption of laser because of the thermal population at lower laser level at room temperature. Ant it appears to have been solved by means of the cryogenic temperature, but the total efficiency of the laser system will be decreased as the use of cryogenic temperature. The amplified spontaneous emission (ASE) effect of the amplifier can be relaxed by means of edge-cladded absorption material. And the difficulties of edge cladding can be will solved as the emergence of ceramics. But at present the ceramics exhibits high scattering and many disfigurements, which limited the application in the high-power large-energy laser system. So the edge-cladding of Yb:YAG crystal will be a key issue for solution the ASE in amplifier. In this paper, we will introduce a 10J water-cooled DPSSL system, based on Yb:YAG crystal at room temperature. In this system a new edge cladding method has been used, that the Yb:YAG crystal was edge cladded by Cr:YAG ceramics, which was used as the absorption material of ASE. The amplifier was an active mirror water-cooled room temperature amplifier. With the help of this edge cladding the ASE has been lowered, and about 5 times small signal gain has been obtained in a single pass amplification, which was much higher than the earlier of 2 times. And the wavefront aberrance of the laser beam was also reduced due to the thermal

  2. Comparative study of optical and scintillation properties of Tm3+:YAG, and Tm3+:LuAG single crystals

    NASA Astrophysics Data System (ADS)

    Fujimoto, Yutaka; Sugiyama, Makoto; Yanagida, Takayuki; Wakahara, Shingo; Suzuki, Shotaro; Kurosawa, Shunsuke; Chani, Valery; Yoshikawa, Akira

    2013-09-01

    The optical and scintillation properties of Tm3+-doped yttrium aluminum garnet Y3Al5O12 (YAG) and Tm3+-doped lutetium aluminum garnet Lu3Al5O12 (LuAG) are compared. The Tm3+-doped single crystals were grown by the micro-pulling down (μ-PD) technique. Both crystals demonstrated some emission peaks originated from 4f-4f forbidden transition of Tm3+ under 241Am alpha-ray excitation. The scintillation decay time of Tm3+-doped YAG was similar to that of LuAG. When irradiated by the gamma-rays from a 137Cs source, the relative scintillation light yields of Tm:YAG was 90% greater than that of Tm:LuAG.

  3. Actively Q-switched laser with novel Nd:YAG/YAG polygonal active-mirror

    NASA Astrophysics Data System (ADS)

    Lang, Ye; Chen, Yanzhong; Ge, Wenqi; He, Jianguo; Zhang, Hongbo; Liao, Lifen; Xin, Jianguo; Zhang, Jian; Fan, Zhongwei

    2018-03-01

    In this work, we demonstrate an efficient actively Q-switched laser based on a novel crystal Nd:YAG/YAG polygonal active mirror. A passively cooled crystal Nd:YAG/YAG polygonal active mirror with an end pump scheme was used as the gain medium. For the overlap between the TEM00 laser mode and large gain profile, a cavity was carefully designed with a large fundamental mode volume. With a maximum absorbed power of 3.1 W, a 685 mW average output power with a pulse repetition of 5 kHz was attained, and the corresponding optical-optical and slope efficiency were 22.1% and 27.7%, respectively. The pulse width was 133.9 ns. The beam quality (M 2) was 1.561 in the horizontal direction and 1.261 in the vertical direction.

  4. Efficient dual-wavelength laser at 946 and 1064 nm with compactly combined Nd:YAG and Nd:YVO4 crystals

    NASA Astrophysics Data System (ADS)

    Cho, C. Y.; Chang, C. C.; Chen, Y. F.

    2013-04-01

    We originally employ a compact combination of a Nd:YAG crystal and a Nd:YVO4 crystal to develop an efficient dual-wavelength laser operating at 946 and 1064 nm. We exploit a short Nd:YAG crystal to generate 946 nm laser by reducing the reabsorption loss and a follow-up Nd:YVO4 crystal to generate a 1064 nm laser by absorbing the residual pump light. The output power ratio between the 946 and 1064 nm emissions can be flexibly adjusted from 0.3 to 0.9 by varying the separation between the two output couplers. At an incident pump power of 17 W, the total output power is generally higher than 5.2 W, with an overall optical-to-optical efficiency greater than 30%.

  5. Yb:YAG disc for high energy laser systems

    NASA Astrophysics Data System (ADS)

    Nejezchleb, Karel; Kubát, Jan; Å ulc, Jan; Jelínková, Helena

    2017-02-01

    Large Yb:YAG crystals were grown using of new improved technology enabling to produce YAG crystals without central growth defect. The crystals diameter reached 115-120mm and their central part was used for manufacturing of discs with the diameter larger than 55 mm. Both sides of this discs were polished and coated. Doping concentration of Yb3+ ions in Yb:YAG crystals was measured using of X-ray fluorescence spectrometry. Absorption coefficient of Yb:YAG was measured for different doping concentration of Yb3+ ions. Fluorescence decay time of Yb:YAG was measured at temperatures of 300K and 80 K. We found the fluorescence decay time of the values of 0.95-1 ms at both temperatures stable and independent on the Yb3+ doping concentration in the range of 1-10 at.% Yb/Y demonstrating high chemical purity of grown crystals. Optical homogeneity as measured using of Fizeau double pass interferometer at 633nm resulted with PV values lower than 0.15 λ on clear aperture of 35 mm. Polished surfaces were ideally parallel with the wedge lower than 2 arcsec. Uniformity of laser properties of Yb:YAG was verified by scanning of the disc as active media in plan-convex pulsed laser resonator pumped by semiconductor diode (wavelength 969 nm, pumping beam diameter 100 μm). It was confirmed, that newly developed technology allows to manufacture very large high quality Yb:YAG discs suitable for high power lasers and amplifiers.

  6. Color centers inside crystallic active media

    NASA Astrophysics Data System (ADS)

    Mierczyk, Zygmunt; Kaczmarek, Slawomir M.; Kopczynski, Krzysztof

    1995-03-01

    This paper presents research results on color centers induced by radiation of a xenon lamp in non doped crystals of yttrium aluminum garnet Y3Al5O12 (YAG), strontium- lanthanum aluminate SrLaAlO4 (SLAO), strontium-lanthanum gallate SrLaGa3O7 (SLGO), and in doped crystals: Nd:YAG, Cr, Tm, Ho:YAG (CTH:YAG), Nd:SLAO and Nd:SLGO. In all these investigated crystals under the influence of intensive exposure by xenon lamp radiation additional bands connected with centers O-2, O2 and centers F came up near the short-wave absorption edge. In the case of doped crystals the observed processes are much more complicated. In crystals CTH:YAG the greatest perturbations in relation to basic state are present at the short-wave absorption edge, as well as on areas of absorption bands of ions Cr+3 and Tm+3 conditioning the sensibilization process of ions Ho+3. These spectral structure disturbances essentially influence the efficiency of this process, as proven during generating investigations. In the case of SrLaGa3O7:Nd+3 under the influence of exposure substantial changes of absorption spectrum occurred on spectral areas 346 divided by 368 nm, 429 divided by 441 nm and 450 divided by 490 nm. Those changes have an irreversible character. They disappear not before the plate is being held at oxidizing atmosphere. Investigations of laser rods Nd:SLGO, CTH:YAG, and Nd:YAG in a free generation demonstrated that the color centers of these crystals are induced by pomp radiation from the spectral area up to 450 nm.

  7. Q-switched Nd:YAG/V:YAG microchip 1338 nm laser for laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Jelínková, Helena; Nejezchleb, Karel; Škoda, Václav

    2017-12-01

    Q-switched microchip laser emitting radiation at wavelength 1338nm was tested as a radiation source for laser induced breakdown spectroscopy (LIBS). This laser used sandwich crystal which combined in one piece the cooling part (undoped YAG crystal 4mm long), the active laser part (Nd:YAG crystal 12mm long), and the saturable absorber (V:YAG crystal 0.7mm long). The diameter of this crystal was 5 mm. The microchip resonator consisted of dielectric mirrors directly deposited on the monolith crystal surfaces. The pump mirror (HT @ 808 nm, HR @ 1.3 ¹m) was placed on the undoped YAG part. The output coupler (R = 90% @ 1338 nm) was placed on the V:YAG part. The fibre-coupled 808nm pumping laser diode was operating in pulsed regime (rep. rate 250 Hz, pulse width 300 ¹s, pulse energy 6 mJ). Using this pumping, stable and high reproducible Q-switched pulses were generated at wavelength 1338 nm. Pulse length was 6.2 ns (FWHM) and the mean output power was 33mW. The single pulse energy and peak power was 0.13mJ and 21kW, respectively. Laser was operating in fundamental TEM00 mode. The laser radiation was focused on a tested sample using single plano-convex lens (focal length 75 mm). The focal spot radius was 40 ¹m. The corresponding peak-power density was 0.83GW/cm2. The laser induced break-down was successfully reached and corresponding laser-induced plasma spectra were recorded for set of metallic elements (Cu, Ag, Au, In, Zn, Al, Fe, Ni, Cr) and alloys (Sn-Pb solder, duralumin, stainless-steel, brass). To record the spectra, StellarNet BLACK-Comet concave grating CCD-based spectrometer was used without any special collimation optics. Thanks to used laser wavelength far from the detector sensitivity, no special filtering was needed to overcome the CCD dazzling. The constructed laser could significantly improve repletion-rate of up-to-date LIBS devices.

  8. Passively Q-switched Nd:YAG/Cr(4+):YAG bonded crystal microchip laser operating at 1112  nm and its application for second-harmonic generation.

    PubMed

    Fu, S G; Ouyang, X Y; Liu, X J

    2015-10-10

    A passively Q-switched Nd:YAG/Cr4+:YAG microchip laser operating at 1112 nm is demonstrated. Under a pump power of 5.5 W, a maximum average output power of 623 mW was obtained with T=6% output coupler, corresponding to an optical-to-optical conversion efficiency of 11.3% and a slope efficiency of 19.5%. The minimum pulse width was 2.8 ns, the pulse energy and peak power were 39.3 μJ and 14 kW, respectively. Additionally, based on the 1112 nm laser, a 230 mW 556 nm green-yellow laser was achieved within an LBO crystal.

  9. Highly efficient solar-pumped Nd:YAG laser.

    PubMed

    Liang, Dawei; Almeida, Joana

    2011-12-19

    The recent progress in solar-pumped laser with Fresnel lens and Cr:Nd:YAG ceramic medium has revitalized solar laser researches, revealing a promising future for renewable reduction of magnesium from magnesium oxide. Here we show a big advance in solar laser collection efficiency by utilizing an economical Fresnel lens and a most widely used Nd:YAG single-crystal rod. The incoming solar radiation from the sun is focused by a 0.9 m diameter Fresnel lens. A dielectric totally internally reflecting secondary concentrator is employed to couple the concentrated solar radiation from the focal zone to a 4 mm diameter Nd:YAG rod within a conical pumping cavity. 12.3 W cw laser power is produced, corresponding to 19.3 W/m(2) collection efficiency, which is 2.9 times larger than the previous results with Nd:YAG single-crystal medium. Record-high slope efficiency of 3.9% is also registered. Laser beam quality is considerably improved by pumping a 3 mm diameter Nd:YAG rod.

  10. Y-junctions based on circular depressed-cladding waveguides fabricated with femtosecond pulses in Nd:YAG crystal: A route to integrate complex photonic circuits in crystals

    NASA Astrophysics Data System (ADS)

    Ajates, Javier G.; Romero, Carolina; Castillo, Gabriel R.; Chen, Feng; Vázquez de Aldana, Javier R.

    2017-10-01

    We have designed and fabricated photonic structures such as, Y-junctions (one of the basic building blocks for construction any integrated photonic devices) and Mach-Zehnder interferometers, based on circular depressed-cladding waveguides by direct femtosecond laser irradiation in Nd:YAG crystal. The waveguides were optically characterized at 633 nm, showing nearly mono-modal behaviour for the selected waveguide radius (9 μm). The effect of the splitting angle in the Y structures was investigated finding a good preservation of the modal profiles up to more than 2°, with 1 dB of additional losses in comparison with straight waveguides. The dependence with polarization of these splitters keeps in a reasonable low level. Our designs pave the way for the fabrication of arbitrarily complex 3D photonic circuits in crystals with cladding waveguides.

  11. CIE colorimetric system fails to calculate the chroma of a Nd:YAG crystal under the fluorescent illuminant F7

    NASA Astrophysics Data System (ADS)

    Liu, Yan; Chen, Qinghan; Bu, Xianhui; Feng, Pingyun

    2002-06-01

    The rare earth element neodymium doped yttrium aluminum garnet (Nd:YAG) is a laser crystal widely used for producing laser in the infrared range. Neodymium causes many characteristic absorption peaks in the transmittance spectrum of the Nd:YAG crystal in the visible range. The crystal appears pink under daylight and incandescent light, and colorless under fluorescent light. The colorimetric calculation results of chroma under the CIE standard fluorescent illuminant F7 do not agree with the color appearance under fluorescent light. The calculated chroma values should be near zero to agree with a colorless appearance, but it is actually 11.79 in the CIELAB color space. This failure of the colorimetric calculation is caused by the color matching functions of the CIE colorimetric observers. The color matching functions do not agree with the spectral sensitivity curves of the human eye, especially the x(λ) function does not matches the spectral sensitivity curve of the long wavelength cone photoreceptors.

  12. 160 W 800 fs Yb:YAG single crystal fiber amplifier without CPA.

    PubMed

    Markovic, Vesna; Rohrbacher, Andreas; Hofmann, Peter; Pallmann, Wolfgang; Pierrot, Simonette; Resan, Bojan

    2015-10-05

    We demonstrate a compact and simple two-stage Yb:YAG single crystal fiber amplifier which delivers 160 W average power, 800 fs pulses without chirped pulse amplification. This is the highest average power of femtosecond laser based on SCF. Additionally, we demonstrate the highest small signal gain of 32.5 dB from the SCF in the first stage and the highest extraction efficiency of 42% in the second stage. The excellent performance of the second stage was obtained using the bidirectional pumping scheme, which is applied to SCF for the first time.

  13. Femtosecond-laser inscribed double-cladding waveguides in Nd:YAG crystal: a promising prototype for integrated lasers.

    PubMed

    Liu, Hongliang; Chen, Feng; Vázquez de Aldana, Javier R; Jaque, D

    2013-09-01

    We report on the design and implementation of a prototype of optical waveguides fabricated in Nd:YAG crystals by using femtosecond-laser irradiation. In this prototype, two concentric tubular structures with nearly circular cross sections of different diameters have been inscribed in the Nd:YAG crystals, generating double-cladding waveguides. Under 808 nm optical pumping, waveguide lasers have been realized in the double-cladding structures. Compared with single-cladding waveguides, the concentric tubular structures, benefiting from the large pump area of the outermost cladding, possess both superior laser performance and nearly single-mode beam profile in the inner cladding. Double-cladding waveguides of the same size were fabricated and coated by a thin optical film, and a maximum output power of 384 mW and a slope efficiency of 46.1% were obtained. Since the large diameters of the outer claddings are comparable with those of the optical fibers, this prototype paves a way to construct an integrated single-mode laser system with a direct fiber-waveguide configuration.

  14. Scanning electron microscope comparative surface evaluation of glazed-lithium disilicate ceramics under different irradiation settings of Nd:YAG and Er:YAG lasers.

    PubMed

    Viskic, Josko; Jokic, Drazen; Jakovljevic, Suzana; Bergman, Lana; Ortolan, Sladana Milardovic; Mestrovic, Senka; Mehulic, Ketij

    2018-01-01

    To evaluate the surface of glazed lithium disilicate dental ceramics after irradiation under different irradiation settings of Nd:YAG and Er:YAG lasers using a scanning electron microscope (SEM). Three glazed-press lithium disilicate ceramic discs were treated with HF, Er:YAG, and Nd:YAG, respectively. The laser-setting variables tested were laser mode, repetition rate (Hz), power (W), time of exposure (seconds), and laser energy (mJ). Sixteen different variable settings were tested for each laser type, and all the samples were analyzed by SEM at 500× and 1000× magnification. Surface analysis of the HF-treated sample showed a typical surface texture with a homogenously rough pattern and exposed ceramic crystals. Er:YAG showed no effect on the surface under any irradiation setting. The surface of Nd:YAG-irradiated samples showed cracking, melting, and resolidifying of the ceramic glaze. These changes became more pronounced as the power increased. At the highest power setting (2.25 W), craters on the surface with large areas of melted or resolidified glaze surrounded by globules were visible. However, there was little to no exposure of ceramic crystals or visible regular surface roughening. Neither Er:YAG nor Nd:YAG dental lasers exhibited adequate surface modification for bonding of orthodontic brackets on glazed lithium disilicate ceramics compared with the control treated with 9.5% HF.

  15. Modeling Cr-to-Tm and Cr-to-Tm-to-Ho energy transfer in YAG crystals

    NASA Technical Reports Server (NTRS)

    Swetits, John J.

    1991-01-01

    A systematic analysis of energy transfer processes in crystals of YAG doped with varying concentrations of Cr and Tm is described. Both spectral measurements and measurements of the temporal response to pulsed excitation are used to give independent determinations of the microscopic interaction parameter for Cr to Tm transfer. The different factors in influencing the temperature dependence of the Cr to Tm transfer are discussed. The dependence of the Tm cross-relaxation rate on Tm concentration is determined.

  16. Experimental investigation of a diode-pumped powerful continuous-wave dual-wavelength Nd:YAG laser at 946 and 938.6 nm

    NASA Astrophysics Data System (ADS)

    Chen, F.; Yu, X.; Yan, R. P.; Li, X. D.; Li, D. J.; Yang, G. L.; Xie, J. J.; Guo, J.

    2013-05-01

    In this paper, a diode-pumped high-power continuous-wave (cw) dual-wavelength Nd:YAG laser at 946 and 938.6 nm is reported. By using an end-pumped structure, comparative experiments indicate that a 5 mm-length Nd:YAG crystal with a Nd3+-doping concentration of 0.3 at.% is favorable for high-power laser operation, and the optimal transmissivity of the output coupler is 9%. As a result, a maximum output power of 17.2 W for a dual-wavelength laser at 946 and 938.6 nm is obtained at an incident pump power of 75.9 W, corresponding to a slope efficiency of 26.5%. To the best of our knowledge, this is the highest output power of a quasi-three-level dual-wavelength laser using a conventional Nd:YAG crystal achieved to date. By using a traveling knife-edge method, the beam quality factor and far-field divergence angle at 17 W power level are estimated to be 4.0 and 6.13 mrad, respectively.

  17. Thermal Stress Analysis of a Continuous and Pulsed End-Pumped Nd:YAG Rod Crystal Using Non-Classic Conduction Heat Transfer Theory

    NASA Astrophysics Data System (ADS)

    Mojahedi, Mahdi; Shekoohinejad, Hamidreza

    2018-02-01

    In this paper, temperature distribution in the continuous and pulsed end-pumped Nd:YAG rod crystal is determined using nonclassical and classical heat conduction theories. In order to find the temperature distribution in crystal, heat transfer differential equations of crystal with consideration of boundary conditions are derived based on non-Fourier's model and temperature distribution of the crystal is achieved by an analytical method. Then, by transferring non-Fourier differential equations to matrix equations, using finite element method, temperature and stress of every point of crystal are calculated in the time domain. According to the results, a comparison between classical and nonclassical theories is represented to investigate rupture power values. In continuous end pumping with equal input powers, non-Fourier theory predicts greater temperature and stress compared to Fourier theory. It also shows that with an increase in relaxation time, crystal rupture power decreases. Despite of these results, in single rectangular pulsed end-pumping condition, with an equal input power, Fourier theory indicates higher temperature and stress rather than non-Fourier theory. It is also observed that, when the relaxation time increases, maximum amounts of temperature and stress decrease.

  18. Fine wavelength control in 1.3 μm Nd:YAG lasers by electro-optical crystal lens

    NASA Astrophysics Data System (ADS)

    Lü, Yanfei; Zhang, Jing; Liu, Huilong; Xia, Jing; Fu, Xihong; Zhang, Anfeng

    2014-02-01

    A diode-pumped tunable and multi-wavelength continuous-wave Nd:YAG laser based on the 4F3/2-4I13/2 transition has been demonstrated for the first time. The combination of the glass plane positioned at the Brewster angle and the electro-optical crystal KH2PO4 (KDP) lens formed a Lyot filter in the cavity and compressed the available gain bandwidth. With an adjustable voltage applied to the KDP crystal lens, the laser wavelength could be tuned from 1333.8 to 1338.2 nm. Moreover, we can also realize cw dual-wavelength and triple-wavelength lasers with smaller wavelength separation by adjusting the free spectral range of the Lyot filter.

  19. Effects of carbon dioxide, Nd:YAG and carbon dioxide-Nd:YAG combination lasers at high energy densities on synthetic hydroxyaptite.

    PubMed

    Meurman, J H; Voegel, J C; Rauhamaa-Mäkinen, R; Gasser, P; Thomann, J M; Hemmerle, J; Luomanen, M; Paunio, I; Frank, R M

    1992-01-01

    The aim of this study was to determine the crystalline structure and chemical alterations of synthetic hydroxyapatite after irradiation with either CO2, Nd:YAG or CO2-Nd:YAG combination lasers at high energy densities of 500-3,230 J.cm2. Further, dissolution kinetics of the lased material were analysed and compared with those of unlased apatite. Electron microscopy showed that the lased material consisted of two kinds of crystals. From the micrographs their diameters varied from 600 to 1,200 A and from 3,000 to 6,000 A, respectively. The larger crystals showed 6.9-Angström periodic lattice fringes in the transmission electron microscope. alpha-Tricalcium phosphate (TCP) was identified by X-ray diffraction. Selective-area electron diffraction identified the large crystals to consist of tricalcium phosphate while the smaller crystals were probably hydroxyapatite. Assays of dissolution kinetics showed that at these high energy densities lased material dissolved more rapidly than unlased synthetic hydroxyapatite due to the higher solubility of TCP.

  20. Erbium:YAG laser contouring of the nasal dorsum: a preliminary investigation

    NASA Astrophysics Data System (ADS)

    Truong, Mai T.; Majaron, Boris; Pandoh, Nidhi S.; Wong, Brian J.

    2001-05-01

    In conventional aesthetic rhinoplasty operations, manual or powered rasps are used to reduce the osseo-cartilagenous nasal dorsum. This tactile method requires palpation of the instrument and the dorsum during surgery to estimate the degree of volume reduction, and often requires forceful manipulation of the dorsum which may illicit pain during surgery and contribute to post-operative edema and echymosis. In this preliminary study, we investigated the use of the Erbium:YAG laser ((lambda) equals294 micrometers ) to reduce bone and cartilage using ex-vivo porcine nasal dorsum and human cadaveric tissues. The short pulsed length and high absorption of this laser in biologic tissues results in minimization of thermal injury which are ideal for non- contact optical contouring of osseous and cartilagenous tissues in the face. Two Erbium:YAG lasers were used to ablate fresh porcine nasal bone and compared for their use. One Erbium:YAG laser, the Fidelis Laser, Fontana Medical Lasers, Ljubljana, Slovenija with variable pulse repetition rates (2 to 50 Hz), pulse energy (80 to 1000 mJ), and pulse duration (100, 300, 750 and 1000 microsecond(s) ) was used and compared to the Ultrafine Erbium:YAG laser, Coherent Inc., Santa Clara California, with variable pulse repetition rate (2 to 10 Hz), pulse energy (2-16 J/cm2), and spot diameter (2-6 mm). Only laser parameters approximating the conditions for thermal confinement were evaluated.

  1. Periodic grain-boundary formation in a poly-Si thin film crystallized by linearly polarized Nd:YAG pulse laser with an oblique incident angle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaki, Hirokazu; Horita, Susumu

    2005-01-01

    We investigated the periodic grain-boundary formation in the polycrystalline silicon film crystallized by a linearly polarized Nd:YAG (where YAG is yttrium aluminum garnet) pulse laser with an oblique incident angle {theta}{sub i}=25 deg. , compared with the normal incident angle {theta}{sub i}=0. The alignment of the grain boundary was uncontrollable and fluctuated in the case of the oblique incident and large irradiation pulse number while that in the case of the normal incident was performed stably. It was found that the main cause for its low controllability was the nonphase matching between the periodic surface corrugation of the crystallized siliconmore » film and the periodic temperature profile induced by the laser irradiation. Also, it was found that, in the case of {theta}{sub i}=25 deg. , the dominant periodic width of the grain boundary depended on the pulse number N. That is, it was around {lambda}/(1+sin {theta}{sub i}) for small N{approx_equal}10 and {lambda}/(1-sin {theta}{sub i}) for large N{approx_equal}100 at the laser wavelength of {lambda}=532 nm. In order to explain this dependence, we proposed a model to take into account the periodic corrugation height proportional to the molten volume of the silicon film, the impediment in interference between the incident beam and diffracted beam on the irradiated surface due to the corrugation height, and the reduction of the liquid surface roughness during melting-crystallization process due to liquid-silicon viscosity.« less

  2. Optimizing alignment and growth of low-loss YAG single crystal fibers using laser heated pedestal growth technique.

    PubMed

    Bera, Subhabrata; Nie, Craig D; Soskind, Michael G; Harrington, James A

    2017-12-10

    The effect of misalignments of different optical components in the laser heated pedestal growth apparatus have been modeled using Zemax optical design software. By isolating the misalignments causing the non-uniformity in the melt zone, the alignment of the components was fine-tuned. Using this optimized alignment, low-loss YAG single crystal fibers of 120 μm diameter were grown, with total attenuation loss as low as 0.5 dB/m at 1064 nm.

  3. Tunable, diode side-pumped Er: YAG laser

    DOEpatents

    Hamilton, Charles E.; Furu, Laurence H.

    1997-01-01

    A discrete-element Er:YAG laser, side pumped by a 220 Watt peak-power InGaAs diode array, generates >500 mWatts at 2.94 .mu.m, and is tunable over a 6 nm range near about 2.936 .mu.m. The oscillator is a plano-concave resonator consisting of a concave high reflector, a flat output coupler, a Er:YAG crystal and a YAG intracavity etalon, which serves as the tuning element. The cavity length is variable from 3 cm to 4 cm. The oscillator uses total internal reflection in the Er:YAG crystal to allow efficient coupling of the diode emission into the resonating modes of the oscillator. With the tuning element removed, the oscillator produces up to 1.3 Watts of average power at 2.94 .mu.m. The duty factor of the laser is 6.5% and the repetition rate is variable up to 1 kHz. This laser is useful for tuning to an atmospheric transmission window at 2.935 .mu.m (air wavelength). The laser is also useful as a spectroscopic tool because it can access several infrared water vapor transitions, as well as transitions in organic compounds. Other uses include medical applications (e.g., for tissue ablation and uses with fiber optic laser scalpels) and as part of industrial effluent monitoring systems.

  4. Tunable, diode side-pumped Er:YAG laser

    DOEpatents

    Hamilton, C.E.; Furu, L.H.

    1997-04-22

    A discrete-element Er:YAG laser, side pumped by a 220 Watt peak-power InGaAs diode array, generates >500 mWatts at 2.94 {micro}m, and is tunable over a 6 nm range near about 2.936 {micro}m. The oscillator is a plano-concave resonator consisting of a concave high reflector, a flat output coupler, a Er:YAG crystal and a YAG intracavity etalon, which serves as the tuning element. The cavity length is variable from 3 cm to 4 cm. The oscillator uses total internal reflection in the Er:YAG crystal to allow efficient coupling of the diode emission into the resonating modes of the oscillator. With the tuning element removed, the oscillator produces up to 1.3 Watts of average power at 2.94 {micro}m. The duty factor of the laser is 6.5% and the repetition rate is variable up to 1 kHz. This laser is useful for tuning to an atmospheric transmission window at 2.935 {micro}m (air wavelength). The laser is also useful as a spectroscopic tool because it can access several infrared water vapor transitions, as well as transitions in organic compounds. Other uses include medical applications (e.g., for tissue ablation and uses with fiber optic laser scalpels) and as part of industrial effluent monitoring systems. 4 figs.

  5. Investigation of 2.1-micron lasing properties of Ho:Tm:Cr:YAG crystals under flash-lamp pumping at various operating conditions

    NASA Technical Reports Server (NTRS)

    Kim, Kyong H.; Choi, Young S.; Barnes, Norman P.; Hess, Robert V.; Bair, Clayton H.; Brockman, Philip

    1993-01-01

    Flash-lamp-pumped normal-mode and Q-switched 2.1-micron laser operations of Ho:Tm:Cr:YAG crystals have been evaluated under a wide variety of experimental conditions in order to determine an optimum lasing condition and to characterize the laser outputs. Q-switched laser-output energies equal to, or in some cases exceeding the normal-mode laser energies, were obtained in the form of a strong single spike through an optimization of the opening time of a lithium niobate Q switch. The increase of the normal-mode laser slope efficiency was observed with the increase of the Tm concentration from 2.5 to 4.5 at. pct at operating temperatures from 120 K to near room temperature. Laser transitions were observed only at 2.098 and 2.091 microns under various conditions. The 2.091-micron laser transition appeared to be dominant at high-temperature operations with low-reflective-output couplers.

  6. Passive Q switching of a solar-pumped Nd:YAG laser.

    PubMed

    Lando, M; Shimony, Y; Noter, Y; Benmair, R M; Yogev, A

    2000-04-20

    Passive Q switching is a preferable choice for switching the Q factor of a solar-pumped laser because it requires neither a driver nor an electrical power supply. The superior thermal characteristics and durability of Cr(4+):YAG single crystals as passive Q switches for lamp and diode-pumped high-power lasers has been demonstrated. Here we report on an average power of 37 W and a switching efficiency of 80% obtained by use of a solar-pumped Nd:YAG laser Q switched by a Cr(4+):YAG saturable absorber. Concentration of the pumping solar energy on the laser crystal was obtained with a three-stage concentrator, composed of 12 heliostats, a three-dimensional compound parabolic concentrator (CPC) and a two-dimensional CPC. The water-cooled passive Q switch also served as the laser rear mirror. Repetition rates of as much as 50 kHz, at pulse durations between 190 and 310 ns (FWHM) were achieved. From the experimental results, the saturated single-pass power absorption of the Cr(4+):YAG device was estimated as 3 ? 1%.

  7. High-energy azimuthally polarized laser beam generation from an actively Q-switched Nd:YAG laser with c-cut YVO4 crystal

    NASA Astrophysics Data System (ADS)

    Guo, Jing; Zhang, Baofu; Jiao, Zhongxing; He, Guangyuan; Wang, Biao

    2018-05-01

    A high-energy, azimuthally polarized (AP) and actively Q-switched Nd:YAG laser is demonstrated. The thermal bipolar lensing effect in the Nd:YAG laser rod is used as a polarization discriminator, and a c-cut YVO4 crystal is inserted into the laser cavity to increase the mode-selecting ability of the cavity for AP mode. The laser generated AP pulses with maximum pulse energy as high as 4.2 mJ. To the best of our knowledge, this is the highest pulse energy obtained from an actively Q-switched AP laser. The pulse energy remained higher than 1 mJ over a wide range of repetition rates from 5 kHz to 25 kHz.

  8. Delivery of high energy Er:YAG pulsed laser light at 2.94 µm through a silica hollow core photonic crystal fibre.

    PubMed

    Urich, A; Maier, R R J; Mangan, B J; Renshaw, S; Knight, J C; Hand, D P; Shephard, J D

    2012-03-12

    In this paper the delivery of high power Er:YAG laser pulses through a silica hollow core photonic crystal fibre is demonstrated. The Er:YAG wavelength of 2.94 µm is well beyond the normal transmittance of bulk silica but the unique hollow core guidance allows silica to guide in this regime. We have demonstrated for the first time the ability to deliver high energy pulses through an all-silica fibre at 2.94 µm. These silica fibres are mechanically and chemically robust, biocompatible and have low sensitivity to bending. A maximum pulse energy of 14 mJ at 2.94 µm was delivered through the fibre. This, to our knowledge, is the first time a silica hollow core photonic crystal fibre has been shown to transmit 2.94 μm laser light at a fluence exceeding the thresholds required for modification (e.g. cutting and drilling) of hard biological tissue. Consequently, laser delivery systems based on these fibres have the potential for the realization of novel, minimally-invasive surgical procedures.

  9. Holmium:YAG surgical lasers.

    PubMed

    1995-03-01

    "Holmium:YAG (Ho:YAG)" is the shorthand name for a family of solid-state lasers that use the doping element holmium in a laser crystal (e.g., YAG [yttrium-aluminum-garnet]) and that emit energy at approximately 2.1 microns. This wavelength is relatively new to medicine and has been used in laser surgery for only about the last six years. Like the carbon dioxide (CO2) laser when it was first used clinically, the Ho:YAG laser is poised for rapid and wide-spread use. Ho:YAG lasers, like CO2 lasers, offer precise cutting with minimal damage to adjacent tissue; however, unlike CO2 lasers, they also offer fiberoptic delivery (which is ideal for endoscopic use) and the ability to treat tissue in a liquid-filled environment (e.g., saline, blood). The initial specialty for which the Ho:YAG laser was used was arthroscopic surgery, especially diskectomy. Today, it is effectively used in many surgical specialties, including general surgery, urology, laparoscopy, neurosurgery, lithotripsy, angioplasty, orthopedic surgery (which includes procedures such as meniscectomy, bone sculpting [may also be performed in plastic surgery], and some experimental surgery, such as cartilage shrinking to tighten loose joints), and dentistry. Because of its broad range of potential applications, it has been called the "Swiss Army Knife" of lasers. High-powered Ho:YAG lasers, which enable surgeons to work more quickly and cut more smoothly, have been made available only within the last three years (units offering > 20 W) to 18 months (units offering > 60 W). Because of this rapid increase, high-powered units are still relatively expensive, and it is not yet clear whether maximum power outputs will continue to increase or whether the cost of higher-power units will begin to come down. Although low-power and high-power Ho:YAG lasers can be used for the same procedures, their different ranges of possible clinical techniques make them better suited to different applications: low-power units are

  10. High-efficient Nd:YAG microchip laser for optical surface scanning

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Jelínková, Helena; Nejezchleb, Karel; Škoda, Václav

    2017-12-01

    A CW operating, compact, high-power, high-efficient diode pumped 1064nm laser, based on Nd:YAG active medium, was developed for optical surface scanning and mapping applications. To enhance the output beam quality, laser stability, and compactness, a microchip configuration was used. In this arrangement the resonator mirrors were deposited directly on to the laser crystal faces. The Nd-doping concentration was 1 at.% Nd/Y. The Nd:YAG crystal was 5mm long. The laser resonator without pumping radiation recuperation was investigated {the output coupler was transparent for pumping radiation. For the generated laser radiation the output coupler reflectivity was 95%@1064 nm. The diameter of the samples was 5 mm. For the laser pumping two arrangements were investigated. Firstly, a fibre coupled laser diode operating at wavelength 808nm was used in CW mode. The 400 ¹m fiber was delivering up to 14W of pump power amplitude to the microchip laser. The maximum CW output power of 7.2W @ 1064nm in close to TEM00 beam was obtained for incident pumping power 13.7W @ 808 nm. The differential efficiency in respect to the incident pump power reached 56 %. Secondly, a single-emitter, 1W laser diode operating at 808nm was used for Nd:YAG microchip pumping. The laser pumping was directly coupled into the microchip laser using free-space lens optics. Slope efficiency up to 70% was obtained in stable, high-quality, 1064nm laser beam with CW power up to 350mW. The system was successfully used for scanning of super-Gaussian laser mirrors reflectivity profile.

  11. Single-Frequency Nd:YAG Ring Lasers with Corner Cube Prism

    NASA Astrophysics Data System (ADS)

    Wu, Ke-Ying; Yang, Su-Hui; Zhao, Chang-Ming; Wei, Guang-Hui

    2000-10-01

    We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single-frequency generating power. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix.

  12. Optical triggering of a Q-switched Nd:YAG laser via transverse bleaching of a Cr:YAG saturable absorber.

    PubMed

    Cole, Brian; Lei, Jonathan; DiLazaro, Tom; Schilling, Bradley; Goldberg, Lew

    2009-11-01

    Optical triggering via direct bleaching of a Cr:YAG saturable absorber was applied to a monolithic Nd:YAG/Cr:YAG laser crystal. The method uses a single laser diode bar to bleach a thin sheet within the saturable absorber from a direction orthogonal to the lasing axis. By placing the Q-switch at the time corresponding to the steepest slope (dT/dt) for change in transmission during bleaching, the pulse-to-pulse timing jitter showed a 13.2x reduction in standard deviation, from 132 ns for free-running operation to 10 ns with optical triggering. We measured that a fluence of 60 kW/cm(2) was sufficient to enable optical triggering, where a diode appropriately sized for the length of the Cr:YAG (approximately 3 mm) would then require only approximately 150 W of optical power over a 1-2 micros duration to enable effective jitter reduction. Additionally, we measured an increase in optical-to-optical efficiency with optical triggering, where the efficiency improved from 12% to 13.5%.

  13. Thermo-optical and spectroscopic properties of Nd:YAG fine grain ceramics: towards a better performance than the Nd:YAG laser crystals

    NASA Astrophysics Data System (ADS)

    Santos, W. Q.; Benayas, A.; Jaque, D.; García-Solé, J.; Catunda, T.; Jacinto, C.

    2016-02-01

    In this work, we investigated the thermo-optical properties of highly Nd3+ doped YAG ceramics. The normalized lifetime thermal lens method was used to obtain the fluorescence quantum efficiency (η) versus Nd3+ concentration (N t) and to study the energy transfer microparameters C DD and C DA. The N t dependence of η was compared to the results of the previous literature. The C DA found is very similar to those of the previous literature, while the C DD is very different and higher than C DA, although the main dependence of η with N t is assigned to C DA. The figure of merit (η.N t versus N t) indicated a maximum around 3.8 at.% Nd2O3, which in addition to the very low ds/dT value, evidences the YAG ceramic as an excellent material for an ultra-high-power microchip laser system and for devices requiring minimum pump-induced local heating generation.

  14. YAG glass-ceramic phosphor for white LED (II): luminescence characteristics

    NASA Astrophysics Data System (ADS)

    Tanabe, Setsuhisa; Fujita, Shunsuke; Yoshihara, Satoru; Sakamoto, Akihiko; Yamamoto, Shigeru

    2005-09-01

    Optical properties of the Ce:YAG glass-ceramic (GC) phosphor for the white LED were investigated. Concentration dependence of fluorescence intensity of Ce3+:5d→4f transition in the GC showed a maximum at 0.5mol%Ce2O3. Quantum efficiency (QE) of Ce3+ fluorescence in the GC materials, the color coordinate and luminous flux of electroluminescence of LED composite were evaluated with an integrating sphere. QE increased with increasing ceramming temperature of the as-made glass. The color coordinates (x,y) of the composite were increased with increasing thickness of the GC mounted on a blue LED chip. The effect of Gd2O3 substitution on the optical properties of the GC materials was also investigated. The excitation and emission wavelength shifted to longer side up to Gd/(Y+Gd)=0.40 in molar composition. As a result, the color coordinate locus of the LED with various thickness of the GdYAG-GC shifted to closer to the Planckian locus for the blackbody radiation. These results were explained by partial substitution of Gd3+ ions in the precipitated YAG micro-crystals, leading to the increase of lattice constant of unit cell, which was confirmed by X-ray diffraction.

  15. Electronic refractive index changes and measurement of saturation intensity in Cr3+-doped YAG crystal

    NASA Astrophysics Data System (ADS)

    Kesavulu, C. R.; Moncorgé, R.; Fromager, M.; Ait-Ameur, K.; Catunda, T.

    2018-04-01

    The electronic refractive index variation is associated with the difference in the polarizabilities (Δαp) of the Cr3+ ion in its ground and excited states. In order to further address the physical origin of Δαp in a Cr3+-doped YAG crystal, time-resolved Z-scan measurements were performed and analyzed at λ = 457 nm by using a chopped Ar+ ion laser. It is found a nonlinear refractive index with the real and imaginary parts n2‧ = 2.2 × 10-8 cm2/W and n2‧‧ = 2.8 × 10-10 cm2/W, respectively. The real part is associated with a polarizability difference Δαp = 2.2 × 10-25 cm3. The imaginary part indicates that excited state absorption (ESA) occurs and that Cr:YAG behaves as a saturable absorber. The transient response of the Z-scan signal decreases with the laser intensity as τ-1 = τo-1(1+I/Is), where τo is the excited state lifetime and Is the saturation intensity. By measuring this transient response at different laser intensities, it was possible to confirm the τo value which can be derived from fluorescence measurements and to determine a Is value of 8.3 kW/cm2.

  16. Investigations on nonlinear absorption and nonlinear refraction of a new photonic crystal using Z-scan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shetty, T. C. S., E-mail: tcsshetty@gmail.com; Department of Post Graduate Studies in Physics, St Aloysius College; Sandeep, K. M.

    A new photonic material, (2E)-1-(3-chlorophenyl)-3-(2,4-dichlorophenyl)prop-2-en-1-one (DCPP) was synthesized and crystallised at room temperature. The functional groups of synthesised material were confirmed using FT-IR. The third order nonlinear optical (NLO) properties were investigated using Z-scan technique with 5 ns Nd:YAG laser pulses operating at a wavelength of 532 nm. Linear absorption spectrum of DCPP crystals shows an optical transmittance window and a lower cutoff wavelength of absorption at 380 nm. The direct transition band gap energy was determined using Tauc’s plot. The melting point and thermal stability of the crystal have been investigated by thermo gravimetric analysis/differential thermal analysis (TGA/DTA). Themore » Thermo gravimetric curve showed absence of any phase transition before melting point.« less

  17. Laboratory investigation of the efficacy of holmium:YAG laser irradiation in removing intracanal debris

    NASA Astrophysics Data System (ADS)

    Nuebler-Moritz, Michael; Gutknecht, Norbert; Sailer, Hermann F.; Hering, Peter; Prettl, Wilhelm

    1997-05-01

    Current endodontic therapy involves debridement and disinfection of the root canal by means of mechanical instrumentation and chemical irrigation. However, several studies have shown that these techniques fail to achieve complete cleansing. Recently, lasers have been suggested for use within root canals. This study was conducted to determine the efficacy of Holmium:YAG laser irradiation in removing intracanal debris and smear layer. Root canal surfaces of freshly-extracted human teeth were exposed to pulsed Ho:YAG laser radiation. Subsequently, laser induced structural changes were investigated using scanning electron microscopy. Temperature measurements during irradiation were performed by means of thermocouples. The result of this survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment modalities. However, limitations exist with regard to circumscribed and well-quantified irradiation of root canal surfaces, due to the lack of perpendicular delivery of the laser beam. Additional studies will be required to develop suitable optical transmission systems, in order to achieve complete cleansing and to avoid damage to the periradicular tissues, respectively.

  18. Laser performance and modeling of RE3+:YAG double-clad crystalline fiber waveguides

    NASA Astrophysics Data System (ADS)

    Li, Da; Lee, Huai-Chuan; Meissner, Stephanie K.; Meissner, Helmuth E.

    2018-02-01

    We report on laser performance of ceramic Yb:YAG and single crystal Tm:YAG double-clad crystalline fiber waveguide (CFW) lasers towards the goal of demonstrating the design and manufacturing strategy of scaling to high output power. The laser component is a double-clad CFW, with RE3+:YAG (RE = Yb, Tm respectively) core, un-doped YAG inner cladding, and ceramic spinel or sapphire outer cladding. Laser performance of the CFW has been demonstrated with 53.6% slope efficiency and 27.5-W stable output power at 1030-nm for Yb:YAG CFW, and 31.6% slope efficiency and 46.7-W stable output power at 2019-nm for Tm:YAG CFW, respectively. Adhesive-Free Bond (AFB®) technology enables a designable refractive index difference between core and inner cladding, and designable core and inner cladding sizes, which are essential for single transverse mode CFW propagation. To guide further development of CFW designs, we present thermal modeling, power scaling and design of single transverse mode operation of double-clad CFWs and redefine the single-mode operation criterion for the double-clad structure design. The power scaling modeling of double-clad CFW shows that in order to achieve the maximum possible output power limited by the physical properties, including diode brightness, thermal lens effect, and simulated Brillion scattering, the length of waveguide is in the range of 0.5 2 meters. The length of an individual CFW is limited by single crystal growth and doping uniformity to about 100 to 200 mm lengths, and also by availability of starting crystals and manufacturing complexity. To overcome the limitation of CFW lengths, end-to-end proximity-coupling of CFWs is introduced.

  19. Multi-watt passively Q-switched Yb:YAB/Cr:YAG microchip lasers

    NASA Astrophysics Data System (ADS)

    Serres, Josep Maria; Loiko, Pavel; Mateos, Xavier; Liu, Junhai; Zhang, Huaijing; Yumashev, Konstantin; Griebner, Uwe; Petrov, Valentin; Aguiló, Magdalena; Díaz, Francesc

    2017-02-01

    A trigonal 5.6 at.% Yb:YAl3(BO3)4 (Yb:YAB) crystal is employed in continuous-wave (CW) and passively Q-switched microchip lasers pumped by a diode at 978 nm. Using a 3 mm-thick, c-cut Yb:YAB crystal, which has a higher pump absorption efficiency, efficient CW microchip laser operation is demonstrated. This laser generated a maximum output power of 7.18 W at 1041-1044 nm with a slope efficiency η of 67% (with respect to the absorbed pump power) and an almost diffraction-limited beam, M2 x,y < 1.1. Inserting a Cr:YAG saturable absorber, stable passive Q-switching of the Yb:YAB microchip laser was obtained. The maximum average output power from the Yb:YAB/Cr:YAG laser reached 2.82 W at 1042 nm with η = 53% and a conversion efficiency with respect to the CW mode of 65% (when using a 0.7 mm-thick Cr:YAG). The latter corresponded to a pulse duration and energy of 7.1 ns / 47 μJ at a pulse repetition rate (PRR) of 60 kHz. Using a 1.3 mm-thick Cr:YAG, 2.02 W were achieved at 1041 nm corresponding to η = 38%. The pulse characteristics were 4.9 ns / 83 μJ at PRR = 24.3 kHz and the maximum peak power reached 17 kW. Yb:YAB crystals are very promising for compact sub-ns power-scalable microchip lasers.

  20. 12 mJ Yb:YAG/Cr:YAG microchip laser

    NASA Astrophysics Data System (ADS)

    Guo, Xiaoyang; Tokita, Shigeki; Kawanaka, Junji

    2018-02-01

    By cryogenically cooling the Yb:YAG/Cr:YAG medium, one can break through the damage limit of Yb:YAG/Cr:YAG passively Q-switched microchip lasers at room temperature and thus achieve a shorter minimum pulse duration. In the proof of principle experiment we carried out, a 160.6 ps pulse duration was obtained. To the best of our knowledge, this is the first realization of sub-200 ps pulse operation for an Yb:YAG/Cr:YAG microchip laser

  1. Micro-pulling-down furnace modification and single crystal fibers growth

    NASA Astrophysics Data System (ADS)

    Yuan, Dongsheng; Jia, Zhitai; Li, Yang; Wu, Baiyi; Tao, Xutang

    2016-03-01

    Single crystal fiber (SCF) combines the excellent instinct properties of conventional bulk laser crystals, and the special geometry advantage of active optical fibers. YAG and LuAG are proper host candidates for single crystal fiber laser with high thermal conductivity. Despite a lower thermal conductivity for pure crystal than YAG, LuAG crystal is easier to obtain homogeneous optical quality, and has a thermal conductivity nearly independent from the doping level. Micropulling- down (μ-PD) has relatively small thermal gradient, and here we use μ-PD to carry out high quality SCFs. Through the μ-PD furnace manufactured by ourselves, crystal fibers with different diameters have been grown successfully. We designed and fabricated a method to adjust the thermal distribution, and with the favor of pulling-down rate, the specific diameter can be controlled perfectly. The crystalline quality and homogeneity along the whole fiber were investigated, and LuAG SCF was confirmed to have a fine crystal quality for laser.

  2. A compact Nd:YAG DPSSL using diamond-cooled technology

    NASA Astrophysics Data System (ADS)

    Chou, Hsian P.; Wang, Yu-Lin; Hasson, Victor H.; Trainor, Daniel W.

    2005-03-01

    In our diamond-cooled approach, thin disks of laser gain material, e.g., Nd:YAG, are alternated between thin disks of single crystal synthetic diamond whose heat conductivity is over 2000 W/m-°K. The gain medium is face-pumped (along the optical axis) by the output of laser diode arrays. This optical configuration produces heat transfer from Nd:YAG to the diamond, in the direction of the optical axis, and then heat is rapidly conducted radially outward through the diamond to the cooling fluid circulating at the circumference of the diamond/YAG assembly. This geometry effectively removes the heat from the gain material in a manner that permits the attainment of high power output with excellent beam quality.

  3. Low loss depressed cladding waveguide inscribed in YAG:Nd single crystal by femtosecond laser pulses.

    PubMed

    Okhrimchuk, Andrey; Mezentsev, Vladimir; Shestakov, Alexander; Bennion, Ian

    2012-02-13

    A depressed cladding waveguide with record low loss of 0.12 dB/cm is inscribed in YAG:Nd(0.3at.%) crystal by femtosecond laser pulses with an elliptical beam waist. The waveguide is formed by a set of parallel tracks which constitute the depressed cladding. It is a key element for compact and efficient CW waveguide laser operating at 1064 nm and pumped by a multimode laser diode. Special attention is paid to mechanical stress resulting from the inscription process. Numerical calculation of mode distribution and propagation loss with the elasto-optical effect taken into account leads to the conclusion that the depressed cladding is a dominating factor in waveguide mode formation, while the mechanical stress only slightly distorts waveguide modes.

  4. A comparison of the effects of Nd:YAG and Ho:YAG laser irradiation on dentine and enamel.

    PubMed

    Cernavin, I

    1995-04-01

    This preliminary study was undertaken to investigate the effects of Nd:YAG and Ho:YAG lasers on enamel and dentine of extracted teeth. The Ho:YAG laser (spot size 250 microns, energy density 4160 J/cm2) produced a cleaner puncture in dentine with less melting of the surrounding tissue than did the Nd:YAG laser (spot size 20 microns), energy density 50,000 J/cm2), which produced considerable melting and recrystallization of dentine and was more difficult to control. It was possible to cut enamel and dentine with both lasers, but considerable melted and recrystallized enamel was produced. From the limited observations of this study it appears that the Ho:YAG laser is more suitable for cutting both enamel and dentine than the Nd:YAG laser. More work needs to be done to ascertain the effect on enamel and dentine of modification of the parameters of both lasers.

  5. Primary investigations on the potential of a novel diode pumped Er:YAG laser system for middle ear surgery

    NASA Astrophysics Data System (ADS)

    Stock, Karl; Wurm, Holger; Hausladen, Florian

    2016-02-01

    Flashlamp pumped Er:YAG lasers are successfully used clinically for both precise soft and hard tissue ablation. Since several years a novel diode pumped Er:YAG laser system (Pantec Engineering AG) is available, with mean laser power up to 40 W and pulse repetition rate up to 1 kHz. The aim of the study was to investigate the suitability of the laser system specifically for stapedotomy. Firstly an experimental setup was realized with a beam focusing unit and a computer controlled translation stage to move the samples (slices of porcine bone) with a defined velocity while irradiation with various laser parameters. A microphone was positioned in a defined distance to the ablation point and the resulting acoustic signal of the ablation process was recorded. For comparison, measurements were also performed with a flash lamp pumped Er:YAG laser system. After irradiation the resulting ablation quality and efficacy were determined using light microscopy. Using a high speed camera and "Töpler-Schlierentechnik" the cavitation bubble in water after perforation of a bone slice was investigated. The results show efficient bone ablation using the diode pumped Er:YAG laser system. Also a decrease of the sound level and of the cavitation bubble volume was observed with decreasing pulse duration. Higher repetition rates lead to a slightly increase of thermal side effects but have no influence on the ablation efficiency. In conclusion, these first experiments demonstrate the high potential of the diode pumped Er:YAG laser system for use in middle ear surgery.

  6. Preparation and characterization of highly transparent Nd:YAG/YAG composite ceramics

    NASA Astrophysics Data System (ADS)

    Ma, Benyuan; Zhang, Wei; Shen, Bizhou; Wang, Yuezhong; Song, Haizhi; Li, Feng; Xie, Xiumin; Zhang, Zhibin; Yang, Yongqiang; Guan, Zhouguo

    2018-05-01

    Using the co-precipitated Nd:YAG and YAG powders as raw materials, the Nd:YAG/YAG composite ceramics (Ф 50 mm × 5 mm) were prepared by vacuum sintering (1790 °C 50 h), followed by hot isostatic pressing (HIP) post treatment (1700 °C 2 h, 200 MPa Ar atmosphere) and air annealing (1250 °C 100 h). The optical properties of Nd:YAG/YAG samples were improved markedly by HIP post-treatment, mainly due to the elimination of residual pores in the samples. The composite sample showed a perfect bonding interface from Nd:YAG to YAG regions without obvious grain size difference, pores or other defects. This structure should be responsible for the thermal conductivity larger than that of non-composite sample. The composite sample revealed good optical properties with transmittance up to 83.9% at 1064 nm and 80.8% at 400 nm, and a maximum laser output power of 1.38 KW with the slope efficiency of 36.7% was obtained.

  7. Growth of rare-earth doped single crystal yttrium aluminum garnet fibers

    NASA Astrophysics Data System (ADS)

    Bera, Subhabrata; Nie, Craig D.; Harrington, James A.; Cheng, Long; Rand, Stephen C.; Li, Yuan; Johnson, Eric G.

    2018-02-01

    Rare-earth doped single crystal (SC) yttrium aluminum garnet (YAG) fibers have great potential as high-power laser gain media. SC fibers combine the superior material properties of crystals with the advantages of a fiber geometry. Improving processing techniques, growth of low-loss YAG SC fibers have been reported. A low-cost technique that allows for the growth of optical quality Ho:YAG single crystal (SC) fibers with different dopant concentrations have been developed and discussed. This technique is a low-cost sol-gel based method which offers greater flexibility in terms of dopant concentration. Self-segregation of Nd ions in YAG SC fibers have been observed. Such a phenomenon can be utilized to fabricate monolithic SC fibers with graded index.

  8. Solid state saturable absorbers for Q-switching at 1 and 1.3μm: investigation and modeling

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Arátor, Pavel; Jelínková, Helena; Nejezchleb, Karel; Škoda, Václav; Kokta, Milan R.

    2008-02-01

    Yttrium and Lutecium garnets (YAG and LuAG) doped by Chromium or Vanadium ions (Cr 4+ or V 3+) were investigated as saturable absorbers potentially useful for passive Q-switching at wavelengths 1 μm and/or 1.3 μm. For comparison also color center saturable absorber LiF:F - II and Cobalt doped spinel (Co:MALO) were studied. Firstly, low power absorption spectra were recorded for all samples. Next, absorbers transmission in dependence on incident energy/power density was measured using the z-scan method. Crystals Cr:YAG, Cr:LuAG, V:YAG, and LiF:F - II were tested at wavelength 1064 nm. Therefore Alexandrite laser pumped Q-switched Nd:YAG laser was used as a radiation source (pulse length 6.9 ns, energy up to 1.5 mJ). Crystals V:YAG, V:LuAG, and Co:MALO were tested at wavelength 1338 nm. So diode pumped Nd:YAG/V:YAG microchip laser was used as a radiation source (pulse length 6.2 ns, energy up to 0.1 mJ). Using measured data fitting, and by their comparison with numerical model of a "thick" saturable absorber transmission for Q-switched Gaussian laser beam, following parameters were estimated: saturable absorber initial transmission T 0, saturation energy density w s, ground state absorption cross-section σ GSA, saturated absorber transmission T s, excited state absorption cross-section σ ESA, ratio γ = σ GSA/σ ESA, and absorbing ions density. For V:YAG crystal, a polarization dependence of T s was also investigated. With the help of rate equation numerical solution, an impact of saturable absorber parameters on generated Q-switched pulse properties was studied in plane wave approximation. Selected saturable absorbers were also investigated as a Q-switch and results were compared with the model.

  9. Influence of doping on thermal diffusivity of single crystals used in photonics: measurements based on thermal wave methods.

    PubMed

    Bodzenta, Jerzy; Kaźmierczak-Bałata, Anna; Wokulska, Krystyna B; Kucytowski, Jacek; Łukasiewicz, Tadeusz; Hofman, Władysław

    2009-03-01

    Three crystals used in solid-state lasers, namely, yttrium aluminum garnet (YAG), yttrium orthovanadate (YVO(4)), and gadolinium calcium oxoborate (GdCOB), were investigated to determine the influence of dopants on their thermal diffusivity. The thermal diffusivity was measured by thermal wave method with a signal detection based on mirage effect. The YAG crystals were doped with Yb or V, the YVO(4) with Nd or Ca and Tm, and the GdCOB crystals contained Nd or Yb. In all cases, the doping caused a decrease in thermal diffusivity. The analysis of complementary measurements of ultrasound velocity changes caused by dopants leads to the conclusion that impurities create phonon scattering centers. This additional scattering reduces the phonon mean free path and accordingly results in the decrease of the thermal diffusivity of the crystal. The influence of doping on lattice parameters was investigated, additionally.

  10. Improvement of thermal management in the composite Yb:YAG/YAG thin-disk laser

    NASA Astrophysics Data System (ADS)

    Kuznetsov, I. I.; Mukhin, I. B.; Palashov, O. V.

    2016-04-01

    To improve the thermal management in the composite Yb:YAG/YAG thin-disk laser a new design of laser head is developed. Thermal-induced phase distortions, small signal gain and lasing in the upgraded laser head are investigated and compared with previously published results. A substantial decrease of the thermal lens optical power and phase aberrations and increase of the laser slope efficiency are observed. A continuous-wave laser with 440 W average power and 44% slope efficiency is constructed.

  11. Effects of nano-YAG (Y 3Al 5O 12) crystallization on the structure and photoluminescence properties of Nd 3+-doped K 2O-SiO 2-Y 2O 3-Al 2O 3 glasses

    NASA Astrophysics Data System (ADS)

    Tarafder, Anal; Molla, Atiar Rahaman; Karmakar, Basudeb

    2010-10-01

    Nd 3+-doped precursor glass in the K 2O-SiO 2-Y 2O 3-Al 2O 3 (KSYA) system was prepared by the melt-quench technique. The transparent Y 3Al 5O 12 (YAG) glass-ceramics were derived from this glass by a controlled crystallization process at 750 °C for 5-100 h. The formation of YAG crystal phase, size and morphology with progress of heat-treatment was examined by X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM) and Fourier transformed infrared reflectance spectroscopy (FT-IRRS). The crystallite sizes obtained from XRD are found to increase with heat-treatment time and vary in the range 25-40 nm. The measured photoluminescence spectra have exhibited emission transitions of 4F 3/2 → 4I J ( J = 9/2, 11/2 and 13/2) from Nd 3+ ions upon excitation at 829 nm. It is observed that the photoluminescence intensity and excited state lifetime of Nd 3+ ions decrease with increase in heat-treatment time. The present study indicates that the incorporation of Nd 3+ ions into YAG crystal lattice enhance the fluorescence performance of the glass-ceramic nanocomposites.

  12. Use of the holmium:YAG laser in urology.

    PubMed

    Johnson, D E; Cromeens, D M; Price, R E

    1992-01-01

    The tissue effects of a holmium:YAG (Ho:YAG) laser operating at a wavelength of 2.1 mu with a maximum power of 15 watts (W) and 10 different energy-pulse settings was systematically evaluated on kidney, bladder, prostate, ureteral, and vasal tissue in the dog. In addition, various urologic surgical procedures (partial nephrectomy, transurethral laser incision of the prostate, and laser-assisted vasovasostomy) were performed in the dog, and a laparoscopic pelvic lymph node dissection was carried out in a pig. Although the Ho:YAG laser has a strong affinity for water, precise tissue ablation was achieved in both the contact and non-contact mode when used endoscopically in a fluid medium to ablate prostatic and vesical tissue. Using the usual parameters for tissue destruction (blanching without charring), the depth of thermal injury in the bladder and ureter was kept superficial. In performing partial nephrectomies, a 2-fold reduction in the zone of coagulative necrosis was demonstrated compared to the use of the continuous wave Neodymium:YAG laser (Nd:YAG). When used through the laparoscope, the Ho:YAG laser provided precise cutting and, combined with electrocautery, allowed the dissection to proceed quickly and smoothly. Hemostatic control was adequate in all surgical procedures. Although the results of these investigations are preliminary, our initial experience with the Ho:YAG laser has been favorable and warrants further investigations.

  13. 12  mJ Yb:YAG/Cr:YAG microchip laser.

    PubMed

    Guo, Xiaoyang; Tokita, Shigeki; Kawanaka, Junji

    2018-02-01

    We have developed a quasi-continuous wave diode end-pumped cryogenically cooled Yb:YAG/Cr:YAG passively Q-switched microchip laser. A maximum energy of 12.1 mJ with 3.7 MW of peak power was obtained. To the best of our knowledge, this is the highest energy and peak power obtained by an Yb:YAG/Cr:YAG microchip laser so far.

  14. Ablation of porcine ligamentum flavum with Ho:YAG, q-switched Ho:YAG, and quadrupled Nd:YAG lasers.

    PubMed

    Johnson, Matt R; Codd, Patrick J; Hill, Westin M; Boettcher, Tara

    2015-12-01

    Ligamentum flavum (LF) is a tough, rubbery connective tissue providing a portion of the ligamentous stability to the spinal column, and in its hypertrophied state forms a significant compressive pathology in degenerative spinal stenosis. The interaction of lasers and this biological tissue have not been thoroughly studied. Technological advances improving endoscopic surgical access to the spinal canal makes selective removal of LF using small, flexible tools such as laser-coupled fiber optics increasingly attractive for treatment of debilitating spinal stenosis. Testing was performed to assess the effect of Ho:YAG, Q-switched Ho:YAG, and frequency quadrupled Nd:YAG lasers on samples of porcine LF. The objective was to evaluate the suitability of these lasers for surgical removal of LF. LF was resected from porcine spine within 2 hours of sacrifice and stored in saline until immediately prior to laser irradiation, which occurred within an additional 2 hours. The optical absorbance of a sample was measured over the spectral band from 190 to 2,360 nm both before and after dehydration. For the experiments using the Ho:YAG (λ = 2,080 nm, tp  = 140 µs, FWHM) and Q-Switched Ho:YAG (λ = 2,080 nm, tp  = 260 ns, FWHM) lasers, energy was delivered to the LF through a laser-fiber optic with 600 µm core and NA = 0.39. For the experiment using the frequency quadrupled Nd:YAG laser (λ = 266 nm, tp  = 5 ns FWHM), rather than applying the laser energy through a laser-fiber, the energy was focused through an aperture and lens directly onto the LF. Five experiments were conducted to evaluate the effect of the given lasers on LF. First, using the Ho:YAG laser, the single-pulse laser-hole depth versus laser fluence was measured with the laser-fiber in direct contact with the LF (1 g force) and with a standoff distance of 1 mm between the laser-fiber face and the LF. Second, with the LF remaining in situ and the spine bisected

  15. Single-frequency Nd:YAG ring lasers with corner cube prism

    NASA Astrophysics Data System (ADS)

    Wu, Ke Ying; Yang, Su Hui; Zhao, Chang Ming; Wei, Guang Hui

    2000-04-01

    Kane and Byer reported the first monolithic non-planar miniature ring lasers in 1985. An intrinsic optical diode enforces unidirectional and hence single-frequency oscillation of this device. It has the advantages of compactness, reliability and high efficiency. We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single- frequency generating. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix. The results of our initial experiment are given in the paper.

  16. LD side-pumped Nd:YAG Q-switched laser without water cooling

    NASA Astrophysics Data System (ADS)

    Ling, Ming; Jin, Guang-yong; Tan, Xue-chun; Wu, Zhi-chao; Liang, Zhu

    2009-07-01

    A novel LD side-pumped Nd:YAG Q-switched solid-state laser, which made use of the special pumping strcture with conductive cooling instead of water cooling, was investigated.After selecting an appropriate length and diameter of Nd:YAG laser crystal rod and using three groups of laser diode centimeter bar which was composed by 12 laser diodes and uniformly arranged according to the angle of 120°,side-pumping structure of laser was accomplished.Adopting plano-concave resonator ,mending double end face of laser crystal and designing heat-stability resonator made the resonator steadily oscillate.Laser crystal rod which was tight fastened by copper net was conductively cooled and radiation block was furnished on the external of copper net for increasing the radiation capacity.High reflection gold film was plated on the cooling wall in the opposite way of pumping light, so that the laser crystal was uniformly pumped and the laser with low order mode output.Making the use of pillar lens focus and ray trace computing, reasonable parameters were caculated to couple pumping light to laser with high-efficiency.It was the electrooptic Q-switched which was made to be micro-integration eliminating voltage by KD*P crystal that improved the ratio between acting and unacting.Inner heat radiated from laser in good time with TE cooler and the laser ran at constant temperature with water cooling when the big external heat sink emanated a steady heat to periphery. Experiments revealed that the syetem pumping efficiency riseed by 18% and the laser threshold energy was 192 mJ under the condition of this novel pumping structure. The low mode output of 10-12ns pulse width and the maximum output energy of 98 mJ was achieved with an incident pump energy of 720 mJ in 1064nm.The optical-to-optical conversion efficiency was up to 13. 6 %,and the power instability in 24 h was better than +/-1. 7 %.

  17. Thermal conductivity investigation of adhesive-free bond laser components

    NASA Astrophysics Data System (ADS)

    Li, Da; Hong, Pengda; Vedula, MahaLakshmi; Meissner, Helmuth E.

    2017-02-01

    An interferometric method has been developed and employed at Onyx Optics, Inc. to accurately measure the thermal conductivity of laser-active crystals as function of dopant concentration or inactive materials such as single crystals, optical ceramics and glasses relative to a standard of assumed to be known thermal conductivity [1]. This technique can also provide information on heat transfer resistance at the interface between two materials in close thermal contact. While the technique appears generally applicable to composites between optically homogeneous materials, we report on thermal conductivities and heat transfer coefficients of selected adhesive-free bond (AFB®) laser composites. Single crystal bars and AFB bonded crystal doublets with the combinations of various rare-earth (Nd3+, Yb3+, Er3+, and Tm3+ trivalent ion doped YAG, and un-doped YAG have been fabricated with the AFB technique. By loading the test sample in a vacuum cryostat, with a precisely controlled heat load at one end of the doublets, the temperature distribution inside the single crystal or the composite samples can been precisely mapped by measuring the optical path difference interferometrically, given the material's thermal-optical properties. No measurable heat transfer resistance can be identified for the AFB interfaces between low-concentration doped YAG and un-doped YAG. For the heavily doped RE3+:YAG, for example, 10% Yb:YAG, the thermal conductivity measured in our experiment is 8.3 W/m•K, using the thermal conductivity of undoped YAG reported in [1] as basis. The thermal transfer resistance of the AFB interface with un-doped YAG, if there is any at the AFB interface, could be less than 1.29×10-6 m2•K/W.

  18. Nd:YAG laser ablation and acid resistance of enamel.

    PubMed

    Kwon, Yong Hoon; Kwon, Oh-Won; Kim, Hyung-Il; Kim, Kyo-Han

    2003-09-01

    The acid resistance of Nd:YAG laser-ablated enamel surfaces was studied by evaluating crystal structure, mineral distribution, and fluorescence radiance and image in the present study. For comparison, 37% phosphoric acid etching was performed. The formation of beta-tricalcium phosphate (beta-TCP) was confirmed in the laser-ablated surface. The Ca/P ratio increased after ablation due to mineral re-distribution. In contrast, the Ca/P ratio decreased after acid etching due to mineral loss. The laser-ablated enamels showed a smaller increase of fluorescence radiances and less clear laser confocal scanning microscope images than those observed in the acid-etched enamels. The former suggests a minimized mineral loss. The Nd:YAG laser irradiation will enhance the acid resistance and retard the carious progression in enamel.

  19. Development of an eye-safe solid-state tunable laser transmitter in the 1.4-1.5 μm wavelength region based on Cr4+:YAG crystal for lidar applications

    NASA Astrophysics Data System (ADS)

    Petrova-Mayor, Anna; Wulfmeyer, Volker; Weibring, Petter

    2008-04-01

    An experimental optimization of the efficiency of a gain switched tunable Cr4+:YAG laser at 10 Hz is described. The thermal lensing during pulsed operation was measured. Optimal performance occurred at a crystal temperature of 34 °C and resulted in an output energy of ~7 mJ and a pulse duration of ~35 ns. Tunability in the range of 1350-1500 nm, spectral linewidth of ~200 GHz, and M2<4 are demonstrated. The main laser material parameters are estimated. Such a laser could be employed in a laboratory-based nonscanning lidar system if a narrowband birefringent filter is installed. The tunability will permit the improvement of the Cr4+:YAG transmitter for water-vapor differential absorption lidar if injection seeding is applied.

  20. Stress Tuning of Laser Crystals

    NASA Technical Reports Server (NTRS)

    Carty, Atherton A.

    1995-01-01

    The topic of stress tunable laser crystals is addressed in this study with the purpose of determining the piezo-optic coefficients of a new laser material. This data was collected using a quadruple pass birefringence technique because of its high degree of sensitivity relative to the other methods examined including fringe shift analysis using a Mach-Zender interferometer. A green He-Ne laser was passed through a light chopper and Glan-Thompson prism before entering a crystal of Erbium doped Yttrium Aluminum Garnet (Er:YAG) (used in order to validate the experimental technique). The Er:YAG crystal is mounted in a press mechanism and the laser is quadruple passed through test specimen before being returned through the prism and the orthogonally polarized portion of the beam measured with a optical sensor. At a later stage, the Er:YAG crystal was replaced with a new crystal in order to determine the piezo-optic coefficients of this uncharacterized material. The applied load was monitored with the use of a 50 lb. load cell placed in line with the press. Light transmission readings were taken using a lock-in amplifier while load cell measurements were taken with a voltmeter from a 5 volt, 0.5 amp power supply. Despite the fact that an effective crystal press damping system was developed, size limitations precluded the use of the complete system. For this reason, data points were taken only once per full turn so as to minimize the effect of non uniform load application on the collected data. Good correlation was found in the transmission data between the experimentally determined Er:YAG and the previously known peizo-optic constants of non-doped crystal with which it was compared. The variation which was found between the two could be accounted for by the aforementioned presence of Erbium in the experimental sample (for which exact empirical data was not known). The same test procedure was then carried out on a Yttrium Gallium Aluminum garnet (YGAG) for the purpose of

  1. Holmium:YAG and erbium:YAG laser interaction with hard and soft tissue

    NASA Astrophysics Data System (ADS)

    Charlton, Andrew; Dickinson, Mark R.; King, Terence A.; Freemont, Anthony J.

    1991-06-01

    The holmium YAG and erbium YAG lasers operating at 2.1 micrometers and 2.9 micrometers respectively, are the subject of great interest for various medical applications. The interaction of both these pulsed lasers with biological tissue involves absorption of the radiation by water leading to rapid heating and ablation, however the different absorption coefficients at these two wavelengths give rise to different ablation efficiencies and haemostatic properties for the two lasers. It is this cut/seal ratio that determines for which medical applications each of these lasers is most suited. The lasers were used to produce incisions in various tissues by translating the tissue at fixed speed beneath a focused laser beam. The laser energy density was varied between 100 and 500 J/cm2 and the lasers were operated at 2 Hz. After irradiation the tissues were fixed in formalin, processed routinely into paraffin wax, sectioned at 5 micrometers and stained with haemotoxylin and eosin. This allowed the dimensions of the incisions to be measured, as well as the depth of coagulative denatured tissue surrounding each incision. In this way the cut/seal ratio was determined for both the holmium YAG and erbium YAG laser in a range of hard and soft tissues. Results show that the latent heat of ablation for the holmium YAG laser interacting with soft tissue varies between 20-50 kJ/cm3, almost an order of magnitude larger than with the erbium YAG laser. Furthermore, the depth of coagulative necrosis with holmium YAG extends 100-400 micrometers , compared with 10-30 micrometers for erbium YAG. The two interactions clearly lead to vastly different results suggesting that the holmium YAG laser is suitable for producing lesions in highly vascular tissue where haemostasis is important, whereas the erbium YAG laser is better suited to avascular tissue requiring large depths of incision.

  2. Development and performance characteristics of flash lamp pumped Yb:YAG, Cr:Tm:Ho:YAG, Er:Tm:Ho:YLF laser sources and investigation of their potential biological applications

    NASA Astrophysics Data System (ADS)

    Karadimitriou, N.; Klinkenberg, B.; Papadopoulos, D. N.; Serafetinides, A. A.

    2007-07-01

    Laser ablation for the formation of apodized patterns on intraocular lenses, as an alternative of the conventional injection molding, has been proved to be a very promising new technique. For the precise lenses ablation, the use of suitable laser wavelength and pulse duration, resulting in a small optical penetration depth in the lens and in confinement of the energy deposition in a small volume, as well as the reduced thermal damage to the surrounding tissue, is essential. Mid-infrared laser wavelengths, at which the organic biological simulators absorption coefficient is large, meet well the above conditions. Towards the complete understanding of the intraocular lens ablation procedure and therefore the choice of the optimum laser beam characteristics for the most accurate, efficient and safe surgical application, the comparative study of various mid-infrared laser sources is of great interest. In this work we investigate the potential of the development of three different mid-infrared laser sources, namely the Yb:YAG, the Cr:Tm:Ho:YAG and the Er:Tm:Ho:YLF laser, operating at 1029 nm, 2060 nm and 2080 nm respectively and their ability in forming patterns on biomaterials. Pumping was achieved with conventional Xe flash lamps in a double elliptical pump chamber. A properly designed Pulse-Forming- Network capable of delivering energy up to 800 J, in variable lamp illumination durations is used. Several hundreds of mJoules were achieved from the Yb:YAG laser oscillator and several Joules from the Ho:YAG and Ho:YLF laser oscillators. Free running and Q-switched laser operation studies and preliminary experiments on laser and biomaterials (biopolymers and animal tissues) interactions will be reported.

  3. Ho:YAG Single Crystal Fiber: Fabrication and Optical Characterization

    DTIC Science & Technology

    2014-06-16

    between the 5I8 and 5I7 energy levels. The results verified the absorption peaks suitable for in- band direct pumping at 1908 nm and 1932 nm with the...Efficient high-power Ho:YAG laser directly in- band pumped by a GaSb -based laser diode stack at 1.9 μm,” Appl. Phys. B 106(2), 315–319 (2012). 21. M...characterized for its optical absorption and emission properties involving transitions between the 5I8 and 5I7 energy levels. The results verified

  4. Ceramic planar waveguide laser of non-aqueous tape casting fabricated YAG/Yb:YAG/YAG

    PubMed Central

    Wang, Chao; Li, Wenxue; Yang, Chao; Bai, Dongbi; Li, Jiang; Ge, Lin; Pan, Yubai; Zeng, Heping

    2016-01-01

    Ceramic YAG/Yb:YAG/YAG planar waveguide lasers were realized on continuous-wave and mode-locked operations. The straight waveguide, fabricated by non-aqueous tape casting and solid state reactive sintering, enabled highly efficient diode-pumped waveguide continuous-wave laser with the slope efficiency of 66% and average output power of more than 3 W. The influence of the waveguide structure on the wavelength tunability was also experimentally investiccgated with a dispersive prism. Passively mode-locked operation of the ceramic waveguide laser was achieved by using a semiconductor saturable absorber mirror (SESAM), output 2.95 ps pulses with maximum power of 385 mW at the central wavelength of 1030 nm. PMID:27535577

  5. Investigations on the potential of a low power diode pumped Er:YAG laser system for oral surgery

    NASA Astrophysics Data System (ADS)

    Stock, Karl; Wurm, Holger; Hausladen, Florian; Wagner, Sophia; Hibst, Raimund

    2015-02-01

    Flash lamp pumped Er:YAG-lasers are used in clinical practice for dental applications successfully. As an alternative, several diode pumped Er:YAG laser systems (Pantec Engineering AG) become available, with mean laser power of 2W, 15W, and 30W. The aim of the presented study is to investigate the potential of the 2W Er:YAG laser system for oral surgery. At first an appropriate experimental set-up was realized with a beam delivery and both, a focusing unit for non-contact tissue cutting and a fiber tip for tissue cutting in contact mode. In order to produce reproducible cuts, the samples (porcine gingiva) were moved by a computer controlled translation stage. On the fresh samples cutting depth and quality were determined by light microscopy. Afterwards histological sections were prepared and microscopically analyzed regarding cutting depth and thermal damage zone. The experiments show that low laser power ≤ 2W is sufficient to perform efficient oral soft tissue cutting with cut depth up to 2mm (sample movement 2mm/s). The width of the thermal damage zone can be controlled by the irradiation parameters within a range of about 50μm to 110μm. In general, thermal injury is more pronounced using fiber tips in contact mode compared to the focused laser beam. In conclusion the results reveal that even the low power diode pumped Er:YAG laser is an appropriate tool for oral surgery.

  6. Modeling of thermal lensing in a [1 1 1]-cut Nd:YAG rod with temperature-dependent parameters and different pumping profiles

    NASA Astrophysics Data System (ADS)

    Bričkus, D.; Dement'ev, A. S.

    2017-05-01

    Temperature dependences of the thermo-optical coefficients of YAG crystals are often neglected when thermal lensing in laser rods is investigated, though their influence is very significant. It is especially significant for transversally non-uniform thermal loading. An analytical solution of the heat transfer equation with only the radial heat flow is found in the integral form, which is very convenient for numerical simulations. Uniform, top-hat, parabolic, Gaussian, super-Gaussian and annular heat source distributions are used in the calculations. The generalization of the thermally-induced refractive index change for long enough [1 1 1]-cut YAG rods to the case of temperature-dependent YAG parameters is developed and applied to the calculation of the corresponding optical path differences. Different definitions of the optical power of the aberrated thermal lens (TL) are discussed in detail. It is shown that for each of the heat source distributions, the temperature dependences of the YAG parameters significantly increase (1.5-1.8 times) the paraxial optical power of the induced TL.

  7. Evaluation of erbium:YAG and holmium:YAG laser radiation and dental hard tissue

    NASA Astrophysics Data System (ADS)

    Attrill, David Cameron

    Lasers have become increasingly established in medicine as effective alternatives or adjuncts to conventional techniques. In dentistry, several clinical laser systems have been developed and marketed, but their applications have been limited to soft tissue surgery. To date, no laser has been capable of effectively cutting or modifying the highly mineralised dental tissues of enamel and dentine. The aim of this study was to evaluate two new laser systems for use in dentistry through a series of in vitro experiments. Both generic erbium and holmium lasers have theoretically superior operating characteristics over currently established lasers for applications with dental hard tissues. The two lasers investigated in this study were pulsed Er:YAG (lambda=2.94) a.m. and Cr-Tm-Ho:YAG (lambda=2.1mu.m). Both operated with a macropulse duration of approximately 200lambdas, at pulse repetition rates of 2-8Hz and mean pulse energies up to 230mJ. Radiation was focused using CaF[2] lenses (f=50-120mm). The lasers could be operated with or without the addition of a surface water film at the interaction site. Tissue removal efficiency was expressed as a latent heat of ablation (LHA, kJ/cm[3]) using a modification of the technique described by Charlton et al. (1990). The mean LHA's for the Er:YAG laser were 6.24kJ/cm[3] and 22.99kJ/cm[3] with dentine and enamel respectively without water, and 10.07kJ/cm[3] and 18.73kJ/cm[3] for dentine and enamel with water. The Cr-Tm-Ho:YAG laser was unable to effectively remove enamel at the fluences and pulse energies available; the mean LHA's for the Cr-Tm- Ho:YAG laser with dentine were 82.79kJ/cm3 and 57.57kJ/cm3 with and without water respectively. The Cr-Tm-Ho;YAG was approximately 8-9 times less efficient for tissue removal than the Er:YAG system. Er:YAG tissue removal with water was characterised by clean "surgical" cuts, comparable in histological appearance to those obtained using conventional instrumentation. Some thermal disruption

  8. Er:YAG laser debonding of porcelain veneers

    NASA Astrophysics Data System (ADS)

    Buu, Natalie; Morford, Cynthia; Finzen, Frederick; Sharma, Arun; Rechmann, Peter

    2010-02-01

    The removal of porcelain veneers using Er:YAG lasers has not been previously described in the scientific literature. This study was designed to systematically investigate the efficacy of an Er:YAG laser on veneer debonding without damaging the underlying tooth structure, as well as preserving a new or misplaced veneer. Initially, Fourier Transform Infrared Spectroscopy (FTIR) was used on flat porcelain veneer samples (IPS Empress Esthetic; Ivoclar Vivadent, Amherst, NY) to assess which infrared laser wavelengths are transmitted through the veneer. Additionally, FTIR spectra from a veneer bonding cement (RelyX Veneer Cement A1; 3M ESPE, St. Paul, MN) were obtained. While the veneer material showed no characteristic water absorption bands in the FTIR, the bonding cement has a broad H2O/OH absorption band coinciding with the ER:YAG laser emission wavelength. Consequently Er:YAG laser energy transmission through different veneer thicknesses was measured. The porcelain veneers transmitted 11 - 18 % of the incident Er:YAG laser energy depending on their thicknesses (Er:YAG laser: LiteTouch by Syneron; wavelength 2,940 nm, 10 Hz repetition rate, pulse duration 100 μs at 133 mJ/pulse; straight sapphire tip 1,100 μm diameter; Syneron, Yokneam, Israel). Initial signs of cement ablation occurred at approximately 1.8 - 4.0 J/cm2. This can be achieved by irradiating through the veneer with the fiber tip positioned at a distance of 3-6 mm from the veneer surface, and operating the Er:YAG laser with 133 mJ output energy. All eleven veneers bonded on extracted anterior incisor teeth were easily removed using the Er:YAG laser. The removal occurred without damaging underlying tooth structure as verified by light microscopic investigation (Incident Light Microscope Olympus B 50, Micropublisher RTV 3.3 MP, Image Pro software, Olympus). The debonding mainly occurred at the cement/veneer interface. When the samples were stored in saline solution for 5 days and/or an air-waterspray was

  9. Growth and optical properties of Dy:Y3Al5O12 crystal

    NASA Astrophysics Data System (ADS)

    Pan, Yuxin; Zhou, Shidong; Li, Dongzhen; Liu, Bin; Song, Qingsong; Liu, Jian; Liu, Peng; Ding, Yuchong; Wang, Xiaodan; Xu, Xiaodong; Xu, Jun

    2018-02-01

    High optical quality Dy:Y3Al5O12 (Dy:YAG) crystal has been grown by the Czochralski method. Absorption spectra, fluorescence spectra and fluorescence decay curve of Dy:YAG have been recorded at room temperature. The strongest emission of Dy:YAG crystal is near 583 nm, corresponding to the 4F9/2 → 6H13/2 transition. The Judd-Ofelt parameters Ω2, Ω4 and Ω6 were calculated to be 1.49 × 10-20 cm2, 0.94 × 10-20 cm2 and 3.20 × 10-20 cm2, respectively. The radiative transition rates, branching ratios and the emission cross sections were calculated. The fluorescence and radiative lifetimes are 0.40 ms and 1.02 ms, respectively, resulting in a quantum efficiency of 39.2%. The results indicate that the Dy:YAG crystal would be a promising yellow solid state laser material.

  10. Continuous-wave and Q-switched microchip laser performance of Yb:Y3Sc2Al3O12 crystals.

    PubMed

    Dong, Jun; Ueda, Ken-ichi; Kaminskii, Alexander A

    2008-04-14

    Optical properties of Yb:Y(3)Sc(2)Al(3)O(12) crystal were investigated and compared with those from Yb:YAG crystals. The broad absorption and emission spectra of Yb:Y(3)Sc(2)Al(3)O(12) show that this crystal is very suitable for laser-diode pumping and ultrafast laser pulse generation. Laser-diode pumped continuous-wave and passively Q-switched Yb:Y(3)Sc(2)Al(3)O(12) lasers with Cr(4+):YAG crystals as saturable absorber have been demonstrated for the first time. Continuous-wave output power of 1.12 W around 1032 nm (multi-longitudinal modes) was measured with an optical-to-optical efficiency of 30%. Laser pulses with pulse energy of over 31 microJ and pulse width of 2.5 ns were measured at repetition rate of over 12.7 kHz; a corresponding peak power of over 12 kW was obtained. The longitudinal mode selection by a thin plate of Cr(4+):YAG as an intracavity etalon was also observed in passively Q-switched Yb:Y(3)Sc(2)Al(2)O(12) microchip lasers.

  11. TEM00 mode Nd:YAG solar laser by side-pumping a grooved rod

    NASA Astrophysics Data System (ADS)

    Vistas, Cláudia R.; Liang, Dawei; Almeida, Joana; Guillot, Emmanuel

    2016-05-01

    A simple TEM00 mode solar laser system with a grooved Nd:YAG rod pumped through a heliostat-parabolic mirror system is reported here. The radiation coupling capacity of a fused silica tube lens was combined with the multipass pumping ability of a 2 V-shaped cavity to provide efficient side-pumping along a 4.0 mm diameter grooved Nd:YAG single-crystal rod. TEM00 mode solar laser power of 3.4 W was measured by adopting an asymmetric large-mode laser resonant cavity. Record TEM00 mode solar laser collection efficiency of 3.4 W/m2and slope efficiency of 1.9% was achieved, which corresponds to 1.8 and 2.4 times more than the previous TEM00 mode Nd:YAG solar laser using the PROMES-CNRS heliostat-parabolic mirror system, respectively.

  12. Millijoule-level 20 ps Nd:YAG oscillator-amplifier laser system for investigation of stimulated Raman scattering and optical parametric generation

    NASA Astrophysics Data System (ADS)

    Jelínek, Michal; Kubecek, Vàclav

    2012-06-01

    We report on quasi-continuously pumped oscillator-amplifier laser system. The laser oscillator was based on highly 2.4 at.% doped crystalline Nd:YAG in a bounce geometry and passively mode locked by a semiconductor saturable absorber mirror. Using the cavity dumping technique, 19 ps pulses with the energy of 20 μJ and Gaussian spatial beam profile were generated directly from the oscillator at the repetition rate up to 50 Hz. For applications requiring more energetic pulses the amplification was studied using either an identical highly doped Nd:YAG module in bounce geometry or flashlamp pumped Nd:YAG laser rod. Using compact all diode pumped oscillator-amplifier system, 130 μJ pulses were generated. The flashlamp pumped amplifier with 100 mm long Nd:YAG enabled to obtain higher energy. In the single pass configuration the pulse was amplified to 4.5 mJ, using the double pass configuration the pulse energy was further increased up to 20 mJ with the duration of 25 ps at 10 Hz. The developed laser system was used for investigation of stimulated Raman scattering in Strontium Barium Niobate and optical parametric generation in CdSiP2.

  13. Small Business Innovations (Crystal Components)

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Scientific Materials Corporation, Bozeman, MT developed the SciMax line of improved Nd:Yag crystals under an Small Business Innovation Research (SBIR) contract with Langley Research Center. They reduced the amount of water trapped in the crystals during growth to improve the optical quality and efficiency. Applications of the crystals include fiber optics, telecommunications, welding, drilling, eye surgery and medical instrumentation.

  14. Experimental investigations of the use of an erbium:YAG laser on temporomandibular joint (TMJ) structures: first experimental results

    NASA Astrophysics Data System (ADS)

    Nuebler-Moritz, Michael; Niederdellmann, Herbert; Hering, Peter; Deuerling, Christian; Dammer, Ralf; Behr, M.

    1995-04-01

    The following paper introduces the results of an interdisciplinary research project. With the aid of photomacroscopic examination, light and scanning electron microscope investigations, changes to temporomandibular joint structures were detected in vitro after irradiation with an Erbium:YAG laser system. The solid-state Erbium:YAG laser, operating at a wavelength of 2.94 micrometers was used in the normal- spiking mode. The free-running laser beam was focussed onto freshly excised porcine tissue samples using a 108-mm sapphire lens. In this study the output was generally pulsed at a repetition rate of 4 Hz, with a pulse duration varying from 120 microsecond(s) to 500 microsecond(s) . Between 50 mJ and 500 mJ per pulse were applied to create pinpoint lesions. The optimum average energy density and pulse duration of the Erbium:YAG laser radiation for the purpose of TMJ-surgery (as far as it concerns meniscus and articulating facets) - which means efficient etch rate and minimal adjacent injury - seems to be about 24-42 J/cm2 and 120 microsecond(s) -240 microsecond(s) , respectively.

  15. Stable continuous-wave single-frequency Nd:YAG blue laser at 473 nm considering the influence of the energy-transfer upconversion.

    PubMed

    Wang, Yaoting; Liu, Jianli; Liu, Qin; Li, Yuanji; Zhang, Kuanshou

    2010-06-07

    We report a continuous-wave (cw) single frequency Nd:YAG blue laser at 473 nm end-pumped by a laser diode. A ring laser resonator was designed, the frequency doubling efficiency and the length of nonlinear crystal were optimized based on the investigation of the influence of the frequency doubling efficiency on the thermal lensing effect induced by energy-transfer upconversion. By intracavity frequency doubling with PPKTP crystal, an output power of 1 W all-solid-state cw blue laser of single-frequency operation was achieved. The stability of the blue output power was better than +/- 1.8% in the given four hours.

  16. Performance study of highly efficient 520 W average power long pulse ceramic Nd:YAG rod laser

    NASA Astrophysics Data System (ADS)

    Choubey, Ambar; Vishwakarma, S. C.; Ali, Sabir; Jain, R. K.; Upadhyaya, B. N.; Oak, S. M.

    2013-10-01

    We report the performance study of a 2% atomic doped ceramic Nd:YAG rod for long pulse laser operation in the millisecond regime with pulse duration in the range of 0.5-20 ms. A maximum average output power of 520 W with 180 J maximum pulse energy has been achieved with a slope efficiency of 5.4% using a dual rod configuration, which is the highest for typical lamp pumped ceramic Nd:YAG lasers. The laser output characteristics of the ceramic Nd:YAG rod were revealed to be nearly equivalent or superior to those of high-quality single crystal Nd:YAG rod. The laser pump chamber and resonator were designed and optimized to achieve a high efficiency and good beam quality with a beam parameter product of 16 mm mrad (M2˜47). The laser output beam was efficiently coupled through a 400 μm core diameter optical fiber with 90% overall transmission efficiency. This ceramic Nd:YAG laser will be useful for various material processing applications in industry.

  17. Synthesis, crystal growth, optical, thermal, and mechanical properties of a nonlinear optical single crystal: ammonium sulfate hydrogen sulphamate (ASHS)

    NASA Astrophysics Data System (ADS)

    Sudhakar, K.; Nandhini, S.; Muniyappan, S.; Arumanayagam, T.; Vivek, P.; Murugakoothan, P.

    2018-04-01

    Ammonium sulfate hydrogen sulphamate (ASHS), an inorganic nonlinear optical crystal, was grown from the aqueous solution by slow evaporation solution growth technique. The single-crystal XRD confirms that the grown single crystal belongs to the orthorhombic system with the space group of Pna21. Powder XRD confirms the crystalline nature and the diffraction planes were indexed. Crystalline perfection of grown crystal was analysed by high-resolution X-ray diffraction rocking curve technique. UV-Vis-NIR studies revealed that ASHS crystal has optical transparency 65% and lower cut-off wavelength at 218 nm. The violet light emission of the crystal was identified by photoluminescence studies. The particle size-dependent second-harmonic generation efficiency for ASHS crystal was evaluated by Kurtz-Perry powder technique using Nd:YAG laser which established the existence of phase matching. Surface laser damage threshold value was evaluated using Nd:YAG laser. Optical homogeneity of the crystal was evaluated using modified channel spectrum method through birefringence study. Thermal analysis reveals that ASHS crystal is stable up to 213 °C. The mechanical behaviour of the ASHS crystal was analysed using Vickers microhardness study.

  18. Potential applications of Erbium:YAG laser in periodontics.

    PubMed

    Ishikawa, Isao; Aoki, Akira; Takasaki, Aristeo Atsushi

    2004-08-01

    Since lasers were introduced for the treatment of oral diseases, there has been considerable advancement in technology. As a result, numerous laser systems are currently available for oral use. Neodymium:Yttrium-Aluminum:Garnet (Nd:YAG), carbon dioxide (CO(2)) laser and the semiconductor Diode lasers have already been approved by the US Food and Drug Administration for soft tissue treatment in oral cavity. The Erbium:YAG (Er:YAG) laser was approved in 1997 for hard tissue treatment in dentistry and recent studies have reported positive results. This suggests that the Er:YAG laser system is a promising apparatus, which will be able to revolutionize and improve dental practice, in particular periodontal treatment. In this mini-review, we would like to describe the positive characteristics of the Er:YAG laser which indicate its potential as a new treatment modality in periodontics. Recent findings are summarized briefly to evaluate the potential of the Er:YAG laser for clinical application in periodontics. The Er:YAG laser possesses suitable characteristics for oral soft and hard tissue ablation. Recently, it has been applied for effective elimination of granulation tissue, gingival melanin pigmentation and gingival discoloration. Contouring and cutting of bone with minimal damage and even or faster healing can also be performed with this laser. In addition, irradiation with the Er:YAG laser has a bactericidal effect with reduction of lipopolysaccharide, high ability of plaque and calculus removal, with the effect limited to a very thin layer of the surface and is effective for implant maintenance. The Er:YAG laser seems to be an effective tool for periodontal therapy, however, further clinical and basic investigations are required to confirm its clinical application. Copyright Blackwell Munksgaard, 2004

  19. Theoretical model predictions and experimental results for a wavelength switchable Tm:YAG laser.

    PubMed

    Niu, Yanxiong; Wang, Caili; Liu, Wenwen; Niu, Haisha; Xu, Bing; Man, Da

    2014-07-01

    We present a theoretical model study of a quasi-three-level laser with particular attention given to the Tm:YAG laser. The oscillating conditions of this laser were theoretically analyzed from the point of the pump threshold while taking into account reabsorption loss. The laser oscillation at 2.02 μm with large stimulated emission sections was suppressed by selecting the appropriate coating for the cavity mirrors, then an efficient laser-diode side-pumped continuous-wave Tm:YAG crystal laser operating at 2.07 μm was realized. Experiments with the Tm:YAG laser confirmed the accuracy of the model, and the model was able to accurately predict that the high Stark sub-level within the H36 ground state manifold has a low laser threshold and long laser wavelength, which was achieved by decreasing the transmission of the output coupler.

  20. Morphological and ultrastructural comparative analysis of bone tissue after Er:YAG laser and surgical drill osteotomy.

    PubMed

    Panduric, Dragana Gabric; Juric, Ivona Bago; Music, Svetozar; Molčanov, Krešimir; Sušic, Mato; Anic, Ivica

    2014-07-01

    The purpose of this study was to analyze morphological, chemical, and crystallographic changes of bone tissue after osteotomy performed with an erbium:yttrium-aluminium-garnet (Er:YAG) laser and a low speed pilot drill. Bone blocks were prepared from porcine ribs, and on each block, two tunnel preparations were performed using the Er:YAG laser (pulse energy: 1000 mJ, pulse duration: 300 μs, pulse repetition rate: 20 Hz) or the low-speed surgical pilot drill. The morphological changes of the cortical and the spongious surface of the tunnel preparations were analyzed under the field emission scanning electron microscopy (FE-SEM) at low and high resolution. The distribution and the level of chemical elements in the treated surfaces were evaluated by qualitative and semiquantitative energy dispersive x-ray analysis (SEM-EDX). Diffraction x-ray analysis was used to detect any differences and thermally induced modifications of hydroxyapatite crystals. FE-SEM revealed sharp edges of the Er:YAG preparations, with empty intertrabecular spaces and no signs of carbonization. In the drill group, the surface of the preparations was smooth, completely covered with smear layer and microcracks, and with hairy-like irregularities on the edges. SEM-EDX analysis did not reveal any differences in the number of specific chemical elements between the laser and the drill group. There were no thermally induced modifications of hydroxyapatite crystal structure in the bone tissue in either group. The Er:YAG laser ablation did not cause any chemical or crystallographic changes of the bone tissue. Compared with the drill, Er:YAG laser created well-defined edges of the preparations, and cortical bone had no smear layer.

  1. The possibility of clinical application of the solid state lasers: Nd:YAG, Ho:YAG, and Er:YAG in otolaryngology - head and neck surgery

    NASA Astrophysics Data System (ADS)

    Tomaszewska, M.; Kukwa, A.; Tulibacki, M.; Wójtowicz, P.; Olędzka, I.; Jeżewska, E.

    2007-02-01

    The purpose of this study was to summarize our experiences in clinical application of Nd:YAG, Ho:YAG and Er:YAG in otolaryngology- head and neck surgery. Choosing the laser type and parameters for the particular procedures was based on our previous research on tissue effects of those lasers. During the period of 1993-2006 we performed 3988 surgical procedures with the Nd:YAG laser. Over 87% of those were made for the nasal cavity pathologies as polyps, hyperplasia of inferior nasal turbinate, granulation tissue, postoperative adhesions, vascular malformations, under the local anesthesia conditions. In our experience Nd:YAG laser gives the possibility of good clinical control and low risk of side effects for disorders of high recurrence and frequent interventions necessity, as nasal polyps or respiratory papillomatosis. Nd:YAG assisted uvulopalatoplasty gives an interesting alternative for surgical procedures for snoring and slight/mild OSA-recognized patients. Due to its good hemostatic properties, it is a perfect tool for removal of the chemodectoma from meddle ear. During the period of 1995-2006 we performed 229 surgical procedures with the Ho:YAG laser, mostly for larynx pathologies (adhesion and scar tissue removal). In our experience Ho:YAG laser can serve as a precise laser knife for both soft and bony tissue. The ER:YAG laser still remain under clinical trial. Since 2001 year we performed 24 procedures of removing stone deposits from salivary glands. We believe it may become a promising method to cope with sialolithiasis which allows for glandule function preservation. All of the laser types mentioned above, can be easily coupled with endoscopes, what makes them available for all of the head and necklocalized disorders.

  2. Continuous two-wave lasing in microchip Nd : YAG lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ievlev, Ivan V; Koryukin, Igor' V; Lebedeva, Yu S

    2011-08-31

    Simultaneous two-wave lasing was obtained in microchip end-pumped Nd:YAG lasers at the wavelengths of 1061.5 and 1064.17 nm at room temperature. Laser wave intensities were studied as functions of crystal temperature and pump power. The ranges of parameters were determined in which the two-wave lasing occurs and the reasons for such lasing were established. A model is suggested, which adequately describes the experimental results obtained. (control of radiation parameters)

  3. 120 watt continuous wave solar-pumped laser with a liquid light-guide lens and an Nd:YAG rod.

    PubMed

    Dinh, T H; Ohkubo, T; Yabe, T; Kuboyama, H

    2012-07-01

    We propose a simple and efficient pumping approach for a high-power solar-pumped laser by using a liquid light-guide lens (LLGL) and a hybrid pumping cavity. A 2×2 m Fresnel lens is used as a primary concentrator to collect natural sunlight; 120 W cw laser power and a 4.3% total slope efficiency are achieved with a 6-mm diameter Nd:YAG rod within a 14-mm diameter LLGL. The corresponded collection efficiency is 30.0 W/m(2), which is 1.5 times larger than the previous record. This result is unexpectedly better than that of Cr:Nd:YAG ceramics. It is because the scattering coefficient of Cr:Nd:YAG ceramics is 0.004cm(1), which is 2 times larger than that of the Nd:YAG crystal, although both have similar saturation gains.

  4. 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System

    NASA Technical Reports Server (NTRS)

    Yu, Anthony

    2012-01-01

    The performance of a traditional diode pumped solid-state laser that is typically pumped with 808-nm laser diode array (LDA) and crystalline Nd:YAG was improved by using 885-nm LDAs and ceramic Nd:YAG. The advantage is lower quantum defect, which will improve the thermal loading on laser gain medium, resulting in a higher-performance laser. The use of ceramic Nd:YAG allows a higher Nd dopant level that will make up the lower absorption at the 885-nm wavelength on Nd:YAG. When compared to traditional 808-nm pump, 885-nm diodes will have 30% less thermal load (or wasted heat) and will thus see a similar percentage improvement in the overall laser efficiency. In order to provide a more efficient laser system for future flight missions that require the use of low-repetition- rate (YAG laser crystal. This pumping scheme has many potential advantages for improved reliability, efficiency, thermal management, contamination control, and mechanical flexibility. The advantages of using 885-nm pump diodes in Nd:YAG laser systems are numerous. The epitaxial structures of these 885-nm diodes are aluminum-free. There is a significant reduction in the thermal load generated from the Stokes shift or quantum defects. A Stokes shift is the energetic difference between the pump and laser photons. Pumping at a wavelength band closer to the lasing wavelength can reduce the thermal load by .30% compared to traditional pumping at 808 nm, and increase the optical- to-optical efficiency by the same factor. The slope efficiency is expected to increase with a reduction in the thermal load. The typical crystalline Nd:YAG can be difficult to produce with doping level >1% Nd. To make certain that the absorption at 885 nm is on the same par as the 808-nm diode, the Nd:YAG material needs to be doped with higher concentration of Nd. Ceramic Nd:YAG is the only material that can be tailored

  5. Single, composite, and ceramic Nd:YAG 946-nm lasers

    NASA Astrophysics Data System (ADS)

    Lan, Rui-Jun; Yang, Guang; Zheng-Ping, Wang

    2015-06-01

    Single, composite crystal and ceramic continuous wave (CW) 946-nm Nd:YAG lasers are demonstrated, respectively. The ceramic laser behaves better than the crystal laser. With 5-mm long ceramic, a CW output power of 1.46 W is generated with an optical conversion efficiency of 13.9%, while the slope efficiency is 17.9%. The optimal ceramic length for a 946-nm laser is also calculated. Project supported by the National Natural Science Foundation of China (Grant No. 61405171), the Natural Science Foundation of Shandong Province, China (Grant No. ZR2012FQ014), and the Science and Technology Program of the Shandong Higher Education Institutions of China (Grant No. J13LJ05).

  6. 11-GHz waveguide Nd:YAG laser CW mode-locked with single-layer graphene.

    PubMed

    Okhrimchuk, Andrey G; Obraztsov, Petr A

    2015-06-08

    We report stable, passive, continuous-wave (CW) mode-locking of a compact diode-pumped waveguide Nd:YAG laser with a single-layer graphene saturable absorber. The depressed cladding waveguide in the Nd:YAG crystal is fabricated with an ultrafast laser inscription method. The saturable absorber is formed by direct deposition of CVD single-layer graphene on the output coupler. The few millimeter-long cavity provides generation of 16-ps pulses with repetition rates in the GHz range (up to 11.3 GHz) and 12 mW average power. Stable CW mode-locking operation is achieved by controlling the group delay dispersion in the laser cavity with a Gires-Tournois interferometer.

  7. 11-GHz waveguide Nd:YAG laser CW mode-locked with single-layer graphene

    PubMed Central

    Okhrimchuk, Andrey G.; Obraztsov, Petr A.

    2015-01-01

    We report stable, passive, continuous-wave (CW) mode-locking of a compact diode-pumped waveguide Nd:YAG laser with a single-layer graphene saturable absorber. The depressed cladding waveguide in the Nd:YAG crystal is fabricated with an ultrafast laser inscription method. The saturable absorber is formed by direct deposition of CVD single-layer graphene on the output coupler. The few millimeter-long cavity provides generation of 16-ps pulses with repetition rates in the GHz range (up to 11.3 GHz) and 12 mW average power. Stable CW mode-locking operation is achieved by controlling the group delay dispersion in the laser cavity with a Gires–Tournois interferometer. PMID:26052678

  8. Crystalline perfection and optical studies of L-Histidinium dihydrogen phosphate orthophosphoric acid (LHDP) single crystals

    NASA Astrophysics Data System (ADS)

    Ittyachan, Reena; Arunkumar, A.; Bhagavannarayana, G.

    2015-10-01

    Single crystals of L-Histidinium dihydrogenphosphate orthophosphoric acid (LHDP) were grown by slow evaporation solution growth technique. The grown crystals were confirmed by single crystal X-ray diffraction techniques. The HRXRD rocking curve measurements revealed the crystalline perfection of grown crystal and the absence of structural grain boundaries. The lower optical cut-off wavelength for this crystal was observed at 240 nm. The third order nonlinear refractive index (n2), nonlinear absorption coefficient (β) and susceptibility (χ(3)) were calculated by Z-scan studies using Nd: YAG laser as a source. The single shot laser damage threshold of grown crystal was measured to be 6.286 GW/cm2 using Nd: YAG laser.

  9. Clinical development of holmium:YAG laser prostatectomy

    NASA Astrophysics Data System (ADS)

    Kabalin, John N.

    1996-05-01

    Holmium:YAG (Ho:YAG) laser vaporization and resection of the prostate offers advantages in immediate tissue removal compared to the Neodymium:YAG (Nd:YAG) laser. Ongoing development of appropriate operative techniques and Ho:YAG laser delivery systems suitable for endoscopic prostate surgery, including side-firing optical delivery fibers, have facilitated this approach. We performed Ho:YAG laser prostatectomy in 20 human subjects, including 2 men treated immediately prior to radical prostatectomy to assess Ho:YAG laser effects in the prostate. A total of 18 men were treated in an initial clinical trial of Ho:YAG prostatectomy. Estimated excess hyperplastic prostate tissue averaged 24 g (range 5 - 50 g). A mean of 129 kj Ho:YAG laser energy was delivered, combined with a mean of 11 kj Nd:YAG energy to provide supplemental coagulation for hemostasis. We have observed no significant perioperative or late complications. No significant intraoperative changes in hematocrit or serum electrolytes were documented. In addition to providing acute removal of obstructing prostate tissue, Ho:YAG laser resection allowed tissue specimen to be obtained for histologic examination. A total of 16 of 18 patients (90%) underwent successful removal of their urinary catheter and voiding trial within 24 hours following surgery. Immediate improvement in voiding, comparable to classic transurethral electrocautery resection of the prostate (TURP), was reported by all patients. Ho:YAG laser resection of the prostate appears to be a viable surgical technique associated with minimal morbidity and immediate improvement in voiding.

  10. Single Crystal Faceplate Evaluation

    DTIC Science & Technology

    1993-10-25

    conventional powder phosphor. The utility of garnets is amplified by the high state of the art of liquid phase epitaxy ( LPE ). Liquid phase epitaxy of...7]. Much the research at Allied-Signal, Inc. in garnet layer growth has been involved with the kinetics of crystallization of garnet from LPE melts...acceptable resolution and light output characteristics. Single crystal faceplates being evaluated are composed of yttrium aluminum garnet (YAG) with an

  11. Diode pumped, regenerative Nd:YAG ring amplifier for space application

    NASA Technical Reports Server (NTRS)

    Coyle, D. B.; Kay, Richard B.; Degnan, John J.; Krebs, Danny J.; Seery, Bernard D.

    1992-01-01

    The study reviews the research and development of a prototype laser used to study one possible method of short-pulse production and amplification, in particular, a pulsed Nd:YAG ring laser pumped by laser diode arrays and injected seeded by a 100-ps source. The diode array pumped, regenerative amplifier consists of only five optical elements, two mirrors, one thin film polarizer, one Nd:YAG crystal, and one pockels cell. The pockels cell performed both as a Q-switch and a cavity dumper for amplified pulse ejection through the thin film polarizer. The total optical efficiency was low principally due to the low gain provided by the 2-bar pumped laser head. After comparison with a computer model, a real seed threshold of about 10 exp -15 J was achieved because only about 0.1 percent of the injected energy mode-matched with the ring.

  12. Comparative study of blue laser diode driven cerium-doped single crystal phosphors in application of high-power lighting and display technologies

    NASA Astrophysics Data System (ADS)

    Balci, Mustafa H.; Chen, Fan; Cunbul, A. Burak; Svensen, Øyvind; Akram, M. Nadeem; Chen, Xuyuan

    2018-02-01

    Cerium-doped single crystals (Ce:LuAG, Ce:YAG, Ce:GAGG, Ce:GdYAG) have been investigated as stationary phosphor candidates for blue laser driven solid-state lighting without heat sink. The luminous properties of the single crystals are superior compared to the commercial ceramic powder phosphor wheels (Ce3+: Y3Al5O12). The high-power blue laser diode driven temperature increase of the crystals versus quantum efficiency is experimentally measured and discussed. We have carried out realistic measurements at high excitation power levels and at high temperatures. Limitation of phosphors as stationary sources is determined for commercial usage. The measurements were done without any heat sink to see the relative comparison of SCPs in the worst-case scenarios. The results indicate that Gd and Ga addition decreases the luminescence quenching temperature. Based on their superior properties, these single crystals can serve as potential phosphor candidates for high-power blue diode laser driven picture projectors for the green and red channels.

  13. Highly efficient end-side-pumped Nd:YAG solar laser by a heliostat-parabolic mirror system.

    PubMed

    Almeida, J; Liang, D; Vistas, C R; Guillot, E

    2015-03-10

    We report a large improvement in the collection and slope efficiency of an Nd:YAG solar laser pumped by a heliostat-parabolic mirror system. A conical fused silica lens was used to further concentrate the solar radiation from the focal zone of a 2 m diameter primary concentrator to a Nd:YAG single-crystal rod within a conical pump cavity, which enabled multipass pumping to the active medium. A 56 W cw laser power was measured, corresponding to 21.1  W/m2 record-high solar laser collection efficiency with the heliostat-parabolic mirror system. 4.9% slope efficiency was calculated, corresponding to 175% enhancement over our previous result.

  14. Measurements of striae in CR+ doped YAG laser crystals

    NASA Astrophysics Data System (ADS)

    Cady, Fredrick M.

    1994-12-01

    Striations in Czochralski (CZ) grown crystals have been observed in materials such as GaAs, silicon, photorefractive crystals used for data storage, potassium titanyl phosphate crystals and LiNbO3. Several techniques have been used for investigating these defects including electron microscopy, laser scanning tomography, selective photoetching, X-ray diffuse scattering, interference orthoscopy, laser interferometry and micro-Fourier transform infrared spectroscopy mapping. A 2mm thick sample of the material to be investigated is illuminated with light that is absorbed and non-absorbed by the ion concentration to be observed. The back surface of the sample is focused onto a solid-state image detector and images of the input beam and absorbed (and diffracted) beams are captured at two wavelengths. The variation of the coefficient of absorption asa function of distance on the sample can be derived from these measurements. A Big Sky Software Beamcode system is used to capture and display images. Software has been written to convert the Beamcode data files to a format that can be imported into a spreadsheet program such as Quatro Pro. The spreadsheet is then used to manipulate and display data. A model of the intensity map of the striae collected by the imaging system has been proposed and a data analysis procedure derived. From this, the variability of the attenuation coefficient alpha can be generated. Preliminary results show that alpha may vary by a factor of four or five over distances of 100 mu m. Potential errors and problems have been discovered and additional experiments and improvements to the experimental setup are in progress and we must now show that the measurement techniques and data analysis procedures provide 'real' information. Striae are clearly visible at all wavelengths including white light. Their basic spatial frequency does not change radically, at least when changing from blue to green to white light. Further experimental and theoretical work can

  15. Quantification of holmium:YAG optical tip degradation

    NASA Astrophysics Data System (ADS)

    Mues, Adam C.; Teichman, Joel M. H.; Knudsen, Bodo E.

    2009-02-01

    The holmium:yttrium aluminum garnet (YAG) laser is the gold standard laser for intracorporeal lithotripsy. Optical fibers are utilized to transmit laser energy to the surface of a stone for fragmentation. During lithotripsy, fiber tip degradation (burn back) can occur. The exact mechanism for tip degradation and related factors are not completely understood, and have not been investigated. This characteristic is important because fiber burn back may affect diminish fragmentation efficiency, increase operative time, and increase cost due to the need for fiber replacement. We hypothesize that fiber tip degradation (burn back) varies amongst different commercially available holmium:YAG laser fibers.

  16. Stone Retropulsion with Ho: YAG and Tm: YAG Lasers: A Clinical Practice-Oriented Experimental Study.

    PubMed

    Kamal, Wissam; Kallidonis, Panagiotis; Koukiou, Georgia; Amanatides, Lefteris; Panagopoulos, Vasileios; Ntasiotis, Pantelis; Liatsikos, Evangelos

    2016-11-01

    To compare the retropulsion of stones with the use of holmium: yttrium aluminum garnet (Ho: YAG) laser and thulium: yttrium aluminum garnet (Tm: YAG) laser in settings that could be used in clinical practice. The experimental configuration included a glass tube set in a water bath filled with physiologic saline. Plaster of Paris stones were inserted in the tube. Tm: YAG and Ho: YAG laser systems were used along with a high-speed slow-motion camera. The lasers were activated with different settings. The displacement of the stone was measured according to a custom-made algorithm. Ho: YAG: the retropulsion of stones was the lowest with the energy setting of 0.5 J and the frequency of 20 Hz with long pulse duration. The highest retropulsion was observed in the case of 3 J, 5 Hz, and short pulse. Tm: YAG: the retropulsion of stones was the lowest with the energy setting of 1 J and the frequency of 10 Hz with either long or short pulse duration. Practically, there was no retropulsion at all. The highest retropulsion was observed in the case of 8 J, 5 Hz, and short pulse. Ho: YAG laser has a linear increase in stone retropulsion with increased pulse energy. On the other hand, the retropulsion rate was kept to the minimum with Tm: YAG as much as the energy level of 8 J. The activation of lasers with short pulse resulted in further displacement of the stone. Lower frequency with the same power setting seemed to result in further stone retropulsion. Higher power with the same frequency setting resulted in further displacement of the stone.

  17. YAG Laser Vitreolysis vs Sham YAG Vitreolysis for Symptomatic Vitreous Floaters: A Randomized Clinical Trial.

    PubMed

    Shah, Chirag P; Heier, Jeffrey S

    2017-09-01

    Vitreous floaters are common and can worsen visual quality. YAG vitreolysis is an untested treatment for floaters. To evaluate YAG laser vitreolysis vs sham vitreolysis for symptomatic Weiss ring floaters from posterior vitreous detachment. This single-center, masked, sham-controlled randomized clinical trial was performed from March 25, 2015, to August 3, 2016, in 52 eyes of 52 patients (36 cases and 16 controls) treated at a private ophthalmology practice. Patients were randomly assigned to YAG laser vitreolysis or sham YAG (control). Primary 6-month outcomes were subjective change measured from 0% to 100% using a 10-point visual disturbance score, a 5-level qualitative scale, and National Eye Institute Visual Functioning Questionnaire 25 (NEI VFQ-25). Secondary outcomes included objective change assessed by masked grading of color fundus photography and Early Treatment Diabetic Retinopathy Study best-corrected visual acuity. Fifty-two patients (52 eyes; 17 men and 35 women; 51 white and 1 Asian) with symptomatic Weiss rings were enrolled in the study (mean [SD] age, 61.4 [8.0] years for the YAG laser group and 61.1 [6.6] years for the sham group). The YAG laser group reported greater symptomatic improvement (54%) than controls (9%) (difference, 45%; 95% CI, 25%-64%; P < .001). In the YAG laser group, the 10-point visual disturbance score improved by 3.2 vs 0.1 in the sham group (difference, -3.0; 95% CI, -4.3 to -1.7; P < .001). A total of 19 patients (53%) in the YAG laser group reported significantly or completely improved symptoms vs 0 individuals in the sham group (difference, 53%; 95% CI, 36%-69%, P < .001). Compared with sham, NEI VFQ-25 revealed improved general vision (difference, 16.3; 95% CI, 0.9-31.7; P = .04), peripheral vision (difference, 11.6; 95% CI, 0.8-22.4; P = .04), role difficulties (difference, 17.3; 95% CI, 8.0-26.6; P < .001), and dependency (difference, 5.6; 95% CI, 0.5-10.8; P = .03) among the YAG laser group

  18. Structural, optical, thermal and mechanical properties of Urea tartaric acid single crystals.

    PubMed

    Vinothkumar, P; Rajeswari, K; Kumar, R Mohan; Bhaskaran, A

    2015-06-15

    Urea tartaric acid (UT) an organic nonlinear optical (NLO) material was synthesized from aqueous solution and the crystals were grown by the slow evaporation technique. The single crystal X-ray diffraction (XRD) analysis revealed that the UT crystal belongs to the orthorhombic system. The functional groups of UT have been identified by the Fourier transform infrared spectral studies. The optical transparent window in the visible and near the IR regions was investigated. The transmittance of UT has been used to calculate the refractive index (n) as a function of the wavelength. The nonlinear optical property of the grown crystal has been confirmed by the Kurtz powder second harmonic generation test. The birefringence of the crystal was determined using a tungsten halogen lamp source. The laser induced surface damage threshold for the grown crystal was measured using the Nd:YAG laser. The anisotropic in mechanical property of the grown crystals was studied using Vicker's microhardness tester at different planes. The etch pit density of UT crystals was investigated. The thermal behavior of UT was investigated using the TG-DTA and DSC studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Structural, thermal and optical properties of a semiorganic nonlinear optical single crystal: glycine zinc sulphate.

    PubMed

    Balakrishnan, T; Ramamurthi, K

    2007-10-01

    Glycine zinc sulphate salt was synthesized and the solubility and metastable zonewidth were estimated from the aqueous solution. Single crystals of glycine zinc sulphate were grown by solvent evaporation method from aqueous solution. Grown crystals were characterized by X-ray diffraction and FT-IR spectral analyses. The range and percentage of optical transmission was ascertained by recording UV-vis-NIR spectrum. Thermal properties of the crystal were investigated by thermogravimetric analysis. Microhardness study was carried out on (01-1) face of the grown crystal. Its powder second harmonic generation efficiency was measured using Nd:YAG laser and the value was observed to be 0.7 times that of potassium dihydrogen orthophosphate.

  20. Multi-Fresnel lenses pumping approach for improving high-power Nd:YAG solar laser beam quality.

    PubMed

    Liang, Dawei; Almeida, Joana

    2013-07-20

    To significantly improve the present-day high-power solar laser beam quality, a three-stage multi-Fresnel lenses approach is proposed for side-pumping either a Nd:YAG single-crystal or a core-doped Sm(3+)Nd:YAG ceramic rod. Optimum pumping and laser beam parameters are found through ZEMAX and LASCAD numerical analysis. The proposed scheme offers a uniform absorption profile along the rod. 167 W laser power can be achieved, corresponding to 29.3 W/m(2) collection efficiency. High brightness figure of merit of 8.34 W is expected for the core-doped rod within a convex-concave resonator, which is 1300 times higher than that of the most-recent high-power solar laser.

  1. Primary investigations on the potential of a novel diode pumped Er:YAG laser system for bone surgery

    NASA Astrophysics Data System (ADS)

    Stock, Karl; Diebolder, Rolf; Hausladen, Florian; Wurm, Holger; Lorenz, Swetlana; Hibst, Raimund

    2013-03-01

    Flashlamp pumped Er:YAG-lasers are successfully clinically used for both precise soft and hard tissue ablation. As an alternative, actually a novel diode pumped Er:YAG laser system (Pantec Engineering AG) becomes available, with mean laser power up to 15W and pulse repetition rate up to 1kHz. The aim of the presented study is to investigate the effect of this laser system on bone tissue at various irradiation parameters, particular at repetition rates exceeding 100 Hz. For reproducible experiments, firstly an appropriate experimental set-up was realized with a beam delivery and focusing unit, a computer controlled stepper unit with sample holder, and a shutter unit. It allowed to move the sample (1mm- 3mm sawed slices of pig bone) with a defined velocity while irradiation by various laser parameters. A water spray served to moisten the sample surfaces. After irradiation the grooves were analyzed by light microscopy and laser scanning microscopy regarding to the ablation quality, the groove geometry, the ablation efficacy, and the thermal effects. The resulting grooves are slightly cone shaped (groove depth up to 3mm, width about 200μm) with sharp edges at the surface. At 1W, 200Hz, 5mm/s sample movement and with water irrigation the measured ablation speed Δz/Δt is 10.8 mm/s. The ablation depth per pulse is 54μm. In conclusion, these first experiments demonstrate that the diode pumped Er:YAG laser system is an efficient tool for use in bone surgery.

  2. Development of flashlamp-pumped Q-switched Ho:Tm:Cr:YAG lasers for mid-infrared LIDAR application

    NASA Technical Reports Server (NTRS)

    Choi, Young S.; Kim, Kyong H.; Whitney, Donald A.; Hess, Robert V.; Barnes, Norman P.; Bair, Clayton H.; Brockman, Philip

    1989-01-01

    A flashlamp-pumped 2.1 micron Ho:Tm:Cr:YAG laser was studied for both normal mode and Q-switched operations under a wide variety of experimental conditions in order to optimize performance. Laser output energy, slope efficiency, threshold and pulselength were determined as a function of operating temperature, output mirror reflectivity, input electrical energy and Q-switch opening time. The measured normal-mode laser thresholds of a Ho(3+) (0.45 atomic percent):Tm(3+) (2.5 atomic percent):Cr(3+) (0.8 atomic percent):YAG crystal ranged form 26 to 50 J between 120 and 200 K with slope efficiencies up to 0.36 percent with a 60 percent reflective output mirror. Under Q-switched operation the slope efficiency was 90 percent of the normal-mode result. Development of solid state lasers with Ho(3+), Tm(3+) and/or Er(3+) doped crystals has been pursued by NASA for eye-dafe mid-infrared LIDAR (light detection and ranging) application. As a part of the project, the authors have been working on evaluating Ho(3+):Tm(3+):Cr(3+):YAG crystals for normal-mode and Q-switched 2.1 micron laser operations in order to determine an optimum Tm(3+) concentration under flashlamp pumping conditions. Lasing properties of the Ho(3+) in the mid-infrared region have been studied by many research groups since the early 1960's. However, the technology of those lasers is still premature for lidar application. In order to overcome the inefficiency related to narrow absorption bands of the Ho(3+), Tm(3+) and Er(3+), the erbium has been replaced by chromium. The improvement in flashlamp-pumped Ho(3+) laser efficiency has been demonstrated recently by several research groups by utilizing the broad absorption spectrum of Cr(3+) which covers the flashlamp's emission spectrum. Efficient energy transfer to the Tm(3+) and then the Ho(3+) occurs subsequently. It is known that high Tm(3+) concentration and low Ho(3+) concentration are preferred to achieve a quantum efficiency approaching two and to avoid

  3. An in vitro investigation of the temperature rises produced in dentine by Nd:YAG laser light with and without water cooling.

    PubMed

    Gow, A M; McDonald, A V; Pearson, G J; Setchell, D J

    1999-01-01

    Infrared lasers are reported to have thermal side effects which may damage pulp tissue. This study investigated the thermal effects of the pulsed Nd:YAG laser. Prepared, extracted teeth were measured prior to irradiation. Temperature was recorded using a thermocouple/data logging system. Laser irradiation was carried out with or without water spray for an exposure time of ten seconds. Results indicated that dry irradiation produced unacceptable temperature rises with dentine thicknesses used. Wet irradiation produced a significantly lower temperature rise. It was concluded that the Nd:YAG laser produced thermal effects which could potentially cause pulpal trauma. A water coolant was effective in reducing these thermal effects, but the temperature rise achieved whilst using water coolant may still cause pulpal damage.

  4. A protected annealing strategy to enhanced light emission and photostability of YAG:Ce nanoparticle-based films

    NASA Astrophysics Data System (ADS)

    Revaux, Amelie; Dantelle, Geraldine; George, Nathan; Seshadri, Ram; Gacoin, Thierry; Boilot, Jean-Pierre

    2011-05-01

    A significant obstacle in the development of YAG:Ce nanoparticles as light converters in white LEDs and as biological labels is associated with the difficulty of finding preparative conditions that allow simultaneous control of structure, particle size and size distribution, while maintaining the optical properties of bulk samples. Preparation conditions frequently involve high-temperature treatments of precursors (up to 1400 °C), which result in increased particle size and aggregation, and lead to oxidation of Ce(iii) to Ce(iv). We report here a process that we term protected annealing, that allows the thermal treatment of preformed precursor particles at temperatures up to 1000 °C while preserving their small size and state of dispersion. In a first step, pristine nanoparticles are prepared by a glycothermal reaction, leading to a mixture of YAG and boehmite crystalline phases. The preformed nanoparticles are then dispersed in a porous silica. Annealing of the composite material at 1000 °C is followed by dissolution of the amorphous silica by hydrofluoric acid to recover the annealed particles as a colloidal dispersion. This simple process allows completion of YAG crystallization while preserving their small size. The redox state of Ce ions can be controlled through the annealing atmosphere. The obtained particles of YAG:Ce (60 +/- 10 nm in size) can be dispersed as nearly transparent aqueous suspensions, with a luminescence quantum yield of 60%. Transparent YAG:Ce nanoparticle-based films of micron thickness can be deposited on glass substrates using aerosol spraying. Films formed from particles prepared by the protected annealing strategy display significantly improved photostability over particles that have not been subject to such annealing.A significant obstacle in the development of YAG:Ce nanoparticles as light converters in white LEDs and as biological labels is associated with the difficulty of finding preparative conditions that allow simultaneous

  5. Light and scanning electron microscope investigations comparing calculus removal using an Er:YAG laser and a frequency-doubled alexandrite laser

    NASA Astrophysics Data System (ADS)

    Rechmann, Peter; Hennig, Thomas; Sadegh, Hamid M. M.; Goldin, Dan S.

    1997-05-01

    With respect to lasers emitting within the mid-IR spectral domain fiber applicators are being developed. Intended is the use of these lasers in periodontal therapy and their application inside the gingival pocket. Aim of the study presented here is to compare the effect of an Er:YAG laser on dental calculus with the results following irradiation with a frequency doubled Alexandrite laser. The surface of freshly extracted wisdom teeth and of extracted teeth suffering from severe periodontitis were irradiated with both laser wavelengths using a standardized application protocol. Calculus on the enamel surface, at the enamel cementum junction and on the root surface was irradiated. For light microscope investigations undecalcified histological sections were prepared after treatment. For the scanning electron microscope teeth were dried in alcohol and sputtered with gold. Investigations revealed that with both laser systems calculus can be removed. Using the frequency doubled Alexandrite laser selective removal of calculus is possible while engaging the Er:YAG laser even at lowest energies necessary for calculus removal healthy cementum is ablated without control.

  6. Investigations of Q-switching and mode locking in diode-pumped Nd:YVO4 laser with passive saturable absorbers

    NASA Astrophysics Data System (ADS)

    Kwiatkowski, Jacek; Jabczynski, Jan K.; Zendzian, Waldemar

    2005-03-01

    The saturable absorbers (Cr4+:YAG, GaAs and LiF crystals for 1064-nm wavelength, V3+:YAG crystals for 1340-nm respectively) were examined as passive Mode Lockers and Q-switches in diode pumped Nd:YVO4 lasers in the Z-type resonators. In each case, partially modulated long trains of QML pulses were observed. As a rule, envelopes with about 1 μs duration and more than 50% depth of modulation were observed. For stabilization of the mode locking trains nonlinear crystals (KTP or LBO) as negative feedback elements were inserted. The fully modulated QML trains for intracavity II harmonic conversion at 670-nm wavelength in V3+:YAG Q-switched Nd:YVO4 laser with LBO crystal were demonstrated.

  7. Nd-YAG Laser Treatment for Tracheobronchial Obstruction

    PubMed Central

    Lee, Yu-Chin; Chiang, Kuo-Hwa

    1996-01-01

    The Nd-YAG laser has good tissue penetration and coagulation effects thus has become an important weapon for photoresection of tracheobronchial obstructive lesions since 1980. Treatment of benign lesions including benign tumors and scar tissues using the Nd-YAG laser has good results. In the treatment of malignant tumors however, it has a lower effectivity rate when compared to benign lesions. From July 1984 to September 1995, a total of 65 patients were treated with Nd-YAG laser for tracheobronchial obstruction. There were 32 (49%) malignant tumors and 33 (51%) benign lesions. 116 resections were performed in 48 patients using the non-contact Nd-YAG laser (MBB, Medilas 2) before 1992. Thereafter, another 41 resections were performed in 17 cases using contact Nd-YAG laser (SLT, CL-X). The overall effectivity rate was 60%. The effectivity rate for benign lesions was 81.3% and 39.4% for malignant tumor. The effectivity rate between non-contact and contact Nd-YAG laser was not significantly different. PMID:18493424

  8. Nd-YAG Laser Treatment for Tracheobronchial Obstruction.

    PubMed

    Perng, R P; Lee, Y C; Chiang, K H

    1996-01-01

    The Nd-YAG laser has good tissue penetration and coagulation effects thus has become an important weapon for photoresection of tracheobronchial obstructive lesions since 1980.Treatment of benign lesions including benign tumors and scar tissues using the Nd-YAG laser has good results. In the treatment of malignant tumors however, it has a lower effectivity rate when compared to benign lesions. From July 1984 to September 1995, a total of 65 patients were treated with Nd-YAG laser for tracheobronchial obstruction. There were 32 (49%) malignant tumors and 33 (51%) benign lesions. 116 resections were performed in 48 patients using the non-contact Nd-YAG laser (MBB, Medilas 2) before 1992. Thereafter, another 41 resections were performed in 17 cases using contact Nd-YAG laser (SLT, CL-X). The overall effectivity rate was 60%. The effectivity rate for benign lesions was 81.3% and 39.4% for malignant tumor. The effectivity rate between non-contact and contact Nd-YAG laser was not significantly different.

  9. Habit modification of bis-thiourea zinc chloride (ZTC) semi organic crystals by impurities

    NASA Astrophysics Data System (ADS)

    Ruby Nirmala, L.; Thomas Joseph Prakash, J.

    2013-06-01

    Single crystals of bis-thiourea zinc chloride (ZTC) doped with metal ion (Li+) possess excellent nonlinear optical properties. These crystals were grown by slow evaporation solution growth technique. The effect of Li+ dopant on the growth and properties of ZTC single crystal were investigated and reported. The grown crystals were crystallized in orthorhombic structure with non-centro symmetric space group Pn21a through the parent compound. The amount of dopant incorporated in the parent crystal was revealed by the inductively coupled plasma (ICP-OES) studies. The FT-IR spectroscopy study was done for finding and confirming the functional groups present in the compound. The UV-Visible spectral study was carried out to find the optical behavior and transparency nature of the grown crystal. TG/DTA measurements and Vickers microhardness measurements were traced to find out the thermal and mechanical stability of the grown crystals respectively. Using Nd:YAG laser, the Second harmonic generation (SHG) for the grown crystals were confirmed.

  10. High peak power Q-switched Er:YAG laser with two polarizers and its ablation performance for hard dental tissues.

    PubMed

    Yang, Jingwei; Wang, Li; Wu, Xianyou; Cheng, Tingqing; Jiang, Haihe

    2014-06-30

    An electro-optically Q-switched high-energy Er:YAG laser with two polarizers is proposed. By using two Al(2)O(3) polarizing plates and a LiNbO(3) crystal with Brewster angle, the polarization efficiency is significantly improved. As a result, 226 mJ pulse energy with 62 ns pulse width is achieved at the repetition rate of 3 Hz, the corresponding peak power is 3.6 MW. To our knowledge, such a high peak power has not been reported in literature. With our designed laser, in-vitro teeth were irradiated under Q-switched and free-running modes. Results of a laser ablation experiment on hard dental tissue with the high-peak-power laser demonstrates that the Q-switched Er:YAG laser has higher ablation precision and less thermal damage than the free-running Er:YAG laser.

  11. Solid-state Yb : YAG amplifier pumped by a single-mode laser at 920 nm

    NASA Astrophysics Data System (ADS)

    Obronov, I. V.; Demkin, A. S.; Myasnikov, D. V.

    2018-03-01

    An optical amplifier scheme for ultrashort 1030-nm pulses is proposed based on an Yb : YAG crystal with axial pumping by a transverse single-mode laser at a wavelength of 920 nm. A small-signal gain up to 40 dB per pass with a high output beam quality is demonstrated. The maximum average power is 14 W with a slope efficiency exceeding 50%.

  12. Influence of bis-thiourea nickel nitrate on the structural, optical, electrical, thermal and mechanical behavior of a KDP single crystal for NLO applications

    NASA Astrophysics Data System (ADS)

    Rasal, Y. B.; Shaikh, R. N.; Shirsat, M. D.; Kalainathan, S.; Hussaini, S. S.

    2017-03-01

    A single crystal of bis-thiourea nickel nitrate (BTNN) doped potassium dihydrogen phosphate (KDP) has been grown from solution at room temperature by a slow evaporation technique. The cell parameters of the grown crystals were determined using single crystal x-ray diffraction analysis. The different functional groups of the grown crystal were confirmed using Fourier transform infrared analysis. The improved optical parameters of the grown crystal have been evaluated in the range of 200-900 nm using UV-visible spectral analysis. The grown crystal was transparent in the entire visible region and the band gap value was found to be 4.96 eV. The influence of BTNN on the third order nonlinear optical properties of KDP crystal has been investigated by means of the Z-scan technique. The second harmonic generation (SHG) efficiency of grown crystal measured using a Nd-YAG laser is 1.98 times higher than that of pure KDP. The third order nonlinear optical susceptibility (χ 3) and nonlinear absorption coefficient (β) of BTNN doped KDP crystal is found to be 1.77  ×  10-5 esu and 5.57  ×  10-6 cm W-1 respectively. The laser damage threshold (LDT) energy for the grown crystal has been measured by using a Q-switched Nd:YAG laser source. The bis-thiourea nickel nitrate shows authoritative impact on the dielectric properties of doped crystal. The influence of bis-thiourea nickel nitrate on the mechanical behavior of KDP crystal has been investigated using Vickers microhardness intender. The thermal behavior of BTNN doped KDP crystal has been analyzed by TGA/DTA analysis.

  13. CTE:YAG laser applications in dentistry

    NASA Astrophysics Data System (ADS)

    Shori, Ramesh K.; Fried, Daniel; Featherstone, John D. B.; Kokta, Milan R.; Duhn, Clifford W.

    1998-04-01

    The suitability of CTE:YAG laser radiation was investigated for caries preventive laser treatments and caries ablation. Although, CTE:YAG laser radiation at 2.69 micrometer is less highly absorbed by dental hard tissues than other erbium laser wavelengths, namely 2.79 and 2.94 micrometer, it can readily be transmitted through a conventional low hydroxyl fiber with minimal loss. These studies show that reasonable ablation rates and efficiencies are obtainable with both free running (200 microseconds) and Q-switched (100 ns) laser pulses on both dentin and enamel with the application of a relatively thick layer of water to the tissue surface. The water served to remove tissue char and debris from the ablation site leaving a clean crater. However, mechanical forces produced during the energetic ablative process resulted in peripheral mechanical damage to the tissue. Surface dissolution studies on enamel indicated that CTE:YAG radiation inhibited surface dissolution by organic acid by 60 - 70% compared to unirradiated controls, albeit, at fluences an order of magnitude higher than those required for CO2 laser radiation. This layer system may be suitable for dental hard tissue applications if mechanical damage can be mitigated. This work was supported by NIH/NIDR Grants R29DE12091 and R01DE09958.

  14. Environmentally benign processing of YAG transparent wafers

    NASA Astrophysics Data System (ADS)

    Yang, Yan; Wu, Yiquan

    2015-12-01

    Transparent yttrium aluminum garnet (YAG) wafers were successfully produced via aqueous tape casting and vacuum sintering techniques using a new environmentally friendly binder, a copolymer of isobutylene and maleic anhydride with the commercial name ISOBAM (noted as ISOBAM). Aqueous YAG slurries were mixed by ball-milling, which was followed by de-gassing and tape casting of wafers. The final YAG green tapes were homogenous and flexible, and could be bent freely without cracking. After the drying and sintering processes, transparent YAG wafers were achieved. The microstructures of both the green tape and vacuum-sintered YAG ceramic were observed by scanning electronic microscopy (SEM). Phase compositions were examined by X-ray diffraction (XRD). Optical transmittance was measured in UV-VIS regions with the result that the transmittance is 82.6% at a wavelength of 800 nm.

  15. Crystal growth, structural, optical, mechanical and thermal properties of a new nonlinear optical single crystal: L-Ornithine monohydrochloride.

    PubMed

    Balakrishnan, T; Ramamurthi, K

    2009-03-01

    Amino acid family crystals exhibit excellent nonlinear optical and electro optical properties. l-Ornithine monohydrochloride single crystal, belongs to the amino acid group, was grown by the slow evaporation solution growth technique at room temperature. The grown crystals were characterized by single crystal and powder X-ray diffraction analysis, Fourier transform infrared (FTIR) spectroscopy, TGA, DTA and DSC analyses. UV-vis-NIR spectrum shows excellent transmission in the UV, visible and NIR region (300-1600nm). The mechanical properties of grown crystals were studied using Vickers microhardness tester. Its second harmonic generation efficiency was tested using Nd:YAG laser and is 1.25 times that of KDP.

  16. Efficient bone cutting with the novel diode pumped Er:YAG laser system: in vitro investigation and optimization of the treatment parameters

    NASA Astrophysics Data System (ADS)

    Stock, Karl; Diebolder, Rolf; Hausladen, Florian; Hibst, Raimund

    2014-03-01

    It is well known that flashlamp pumped Er:YAG lasers allow efficient bone ablation due to strong absorption at 3μm by water. Preliminary experiments revealed also a newly developed diode pumped Er:YAG laser system (Pantec Engineering AG) to be an efficient tool for use for bone surgery. The aim of the present in vitro study is the investigation of a new power increased version of the laser system with higher pulse energy and optimization of the treatment set-up to get high cutting quality, efficiency, and ablation depth. Optical simulations were performed to achieve various focus diameters and homogeneous beam profile. An appropriate experimental set-up with two different focusing units, a computer controlled linear stage with sample holder, and a shutter unit was realized. By this we are able to move the sample (slices of pig bone) with a defined velocity during the irradiation. Cutting was performed under appropriate water spray by moving the sample back and forth. After each path the ablation depth was measured and the focal plane was tracked to the actual bottom of the groove. Finally, the cuts were analyzed by light microcopy regarding the ablation quality and geometry, and thermal effects. In summary, the results show that with carefully adapted irradiation parameters narrow and deep cuts (ablation depth > 6mm, aspect ratio approx. 20) are possible without carbonization. In conclusion, these in vitro investigations demonstrate that high efficient bone cutting is possible with the diode pumped Er:YAG laser system using appropriate treatment set-up and parameters.

  17. Efficacy of long pulse Nd:YAG laser versus fractional Er:YAG laser in the treatment of hand wrinkles.

    PubMed

    Robati, Reza M; Asadi, Elmira; Shafiee, Anoosh; Namazi, Nastaran; Talebi, Atefeh

    2018-04-01

    There are different modalities for hand rejuvenation. Fractional Er:YAG laser and long pulse Nd:YAG laser were introduced for treating hand wrinkles. We plan to compare fractional Er:YAG laser and long pulse Nd:YAG laser in a randomized controlled double-blind design with multiple sessions and larger sample size in comparison with previous studies. Thirty-three participants with hand wrinkles entered this study. They were randomly allocated to undergo three monthly laser treatments on each hand, one with a fractional Er:YAG laser and the other with a long pulse Nd:YAG laser. The evaluations included assessment of clinical improvement determined by two independent dermatologists not enrolled in the treatment along with measuring skin biomechanical property of hands using a sensitive biometrologic device with the assessment of cutaneous resonance running time (CRRT). Moreover, potential side effects and patients' satisfaction have been documented at baseline, 1 month after each treatment, and 3 months after the final treatment session. Clinical evaluation revealed both modalities significantly reduce hand wrinkles (p value < 0.05), with no significant difference between two lasers. Mean CRRT values also decreased significantly after the laser treatment compared to those of the baseline in both laser groups. There was no serious persistent side effect after both laser treatments. Both fractional Er:YAG and long pulse Nd:YAG lasers show substantial clinical improvement of hand skin wrinkles with no serious side effects. However, combination treatment by these lasers along with the other modalities such as fat transfer could lead to better outcomes in hand rejuvenation. IRCT2016032020468N4.

  18. Pulsed Nd:YAG laser beam drilling: A review

    NASA Astrophysics Data System (ADS)

    Gautam, Girish Dutt; Pandey, Arun Kumar

    2018-03-01

    Laser beam drilling (LBD) is one of non contact type unconventional machining process that are employed in machining of stiff and high-strength materials, high strength temperature resistance materials such as; metal alloys, ceramics, composites and superalloys. Most of these materials are difficult-to-machine by using conventional machining methods. Also, the complex and precise holes may not be obtained by using the conventional machining processes which may be obtained by using unconventional machining processes. The laser beam drilling in one of the most important unconventional machining process that may be used for the machining of these materials with satisfactorily. In this paper, the attention is focused on the experimental and theoretical investigations on the pulsed Nd:YAG laser drilling of different categories of materials such as ferrous materials, non-ferrous materials, superalloys, composites and Ceramics. Moreover, the review has been emphasized by the use of pulsed Nd:YAG laser drilling of different materials in order to enhance productivity of this process without adverse effects on the drilled holes quality characteristics. Finally, the review is concluded with the possible scope in the area of pulsed Nd:YAG laser drilling. This review work may be very useful to the subsequent researchers in order to give an insight in the area of pulsed Nd:YAG laser drilling of different materials and research gaps available in this area.

  19. Width of thermal damage after using the YAG contact laser for cutting biological tissue: animal experimental investigation.

    PubMed

    Mecke, H; Schünke, M; Schnaidt, S; Freys, I; Semm, K

    1991-01-01

    At the University Women's Clinic in Kiel, the YAG contact laser has been used as a cutting instrument in pelviscopic operations since 1987. When the laser cuts, it produces only a scant amount of mechanical trauma. The determining factor is the amount of thermal damage produced along the wound margins and in direct neighboring tissue. The extent of the tissue change seen in the uterus and liver parenchyma of rats and the striated muscle of rabbits after application of the YAG contact laser was demonstrated using various staining techniques and stains. Liver parenchyma proved to be the most sensitive to thermal damage. In the uterine horn, enzyme-histochemical ATPase and alkaline phosphatase demonstrations showed a significantly wider zone of thermal damage after laser incision than did hematoxylin-eosin and Goldner staining techniques. A good understanding of the extent of thermal damage is essential for atraumatic pelviscopic operations using the YAG contact laser and also for the preventing of complications.

  20. Diode-pumped quasi-three-level Nd:GdV O4-Nd:YAG sum-frequency laser at 464 nm

    NASA Astrophysics Data System (ADS)

    Lu, Jie

    2014-04-01

    We report a laser architecture to obtain continuous-wave (cw) blue radiation at 464 nm. A 808 nm diode pumped a Nd:GdV O4 crystal emitting at 912 nm. A part of the pump power was then absorbed by the Nd:GdV O4 crystal. The remainder was used to pump a Nd:YAG crystal emitting at 946 nm. Intracavity sum-frequency mixing at 912 and 946 nm was then realized in a LiB3O5 (LBO) crystal to produce blue radiation. We obtained a cw output power of 1.52 W at 464 nm with a pump laser diode emitting 18.4 W at 808 nm.

  1. Diode-pumped cw Nd:YAG three-level laser at 869 nm.

    PubMed

    Lü, Yanfei; Xia, Jing; Cheng, Weibo; Chen, Jifeng; Ning, Guobin; Liang, Zuoliang

    2010-11-01

    We report for the first time (to our knowledge) a diode-pumped Nd:YAG laser emitting at 869 nm based on the (4)F(3/2)-(4)I(9/2) transition, generally used for a 946 nm emission. Power of 453 mW at 869 nm has been achieved in cw operation with a fiber-coupled laser diode emitting 35.4 W at 809 nm. Intracavity second-harmonic generation in the cw mode has also been demonstrated with power of 118 mW at 435 nm by using a BiB(3)O(6) nonlinear crystal. In our experiment, we used a LiNbO(3) crystal lens to complement the thermal lens of the laser rod, and we obtained good beam quality and high output power stability.

  2. Investigations on nucleation, HRXRD, optical, piezoelectric, polarizability and Z-scan analysis of L-arginine maleate dihydrate single crystals

    NASA Astrophysics Data System (ADS)

    Sakthy Priya, S.; Alexandar, A.; Surendran, P.; Lakshmanan, A.; Rameshkumar, P.; Sagayaraj, P.

    2017-04-01

    An efficient organic nonlinear optical single crystal of L-arginine maleate dihydrate (LAMD) has been grown by slow evaporation solution technique (SEST) and slow cooling technique (SCT). The crystalline perfection of the crystal was examined using high-resolution X-ray diffractometry (HRXRD) analysis. Photoluminescence study confirmed the optical properties and defects level in the crystal lattice. Electromechanical behaviour was observed using piezoelectric co-efficient (d33) analysis. The photoconductivity analysis confirmed the negative photoconducting nature of the material. The dielectric constant and loss were measured as a function of frequency with varying temperature and vice-versa. The laser damage threshold (LDT) measurement was carried out using Nd:YAG Laser with a wavelength of 1064 nm (Focal length is 35 cm) and the obtained results showed that LDT value of the crystal is high compared to KDP crystal. The high laser damage threshold of the grown crystal makes it a potential candidate for second and higher order nonlinear optical device application. The third order nonlinear optical parameters of LAMD crystal is determined by open-aperture and closed-aperture studies using Z-scan technique. The third order linear and nonlinear optical parameters such as the nonlinear refractive index (n2), two photon absorption coefficient (β), Real part (Reχ3) and imaginary part (Imχ3) of third-order nonlinear optical susceptibility are calculated.

  3. Laboratory and clinical experience with neodymium:YAG laser prostatectomy

    NASA Astrophysics Data System (ADS)

    Kabalin, John N.

    1996-05-01

    Since 1991, we have undertaken extensive laboratory and clinical studies of the Neodymium:YAG (Nd:YAG) laser for surgical treatment of bladder outlet obstruction due to prostatic enlargement or benign prostatic hyperplasia (BPH). Side-firing optical fibers which emit a divergent, relatively low energy density Nd:YAG laser beam produce coagulation necrosis of obstructing periurethral prostate tissue, followed by gradual dissolution and slough in the urinary stream. Laser-tissue interactions and Nd:YAG laser dosimetry for prostatectomy have been studied in canine and human prostate model systems, enhancing clinical application. Ongoing studies examine comparative Nd:YAG laser dosimetry for various beam configurations produced by available side-firing optical fibers and continue to refine operative technique. We have documented clinical outcomes of Nd:YAG laser prostatectomy in 230 consecutive patients treated with the UrolaseTM side-firing optical fiber. Nd:YAG laser coagulation the prostate produces a remarkably low acute morbidity profile, with no significant bleeding or fluid absorption. No postoperative incontinence has been produced. Serial assessments of voiding outcomes over more than 3 years of followup show objective and symptomatic improvement following Nd:YAG laser prostatectomy which is comparable to older but more morbid electrosurgical approaches. Nd:YAG laser prostatectomy is a safe, efficacious, durable and cost-effective treatment for BPH.

  4. Laser reduction of specific microorganisms in the periodontal pocket using Er:YAG and Nd:YAG lasers: a randomized controlled clinical study.

    PubMed

    Grzech-Leśniak, K; Sculean, A; Gašpirc, Boris

    2018-05-15

    The objective of this study was to evaluate the microbiological and clinical outcomes following nonsurgical treatment by either scaling and root planing, combination of Nd:YAG and Er:YAG lasers, or by Er:YAG laser treatment alone. The study involved 60 patients with generalized chronic periodontitis, randomly assigned into one of three treatment groups of 20 patients. The first group received scaling and root planing by hand instruments (SRP group), the second group received Er:YAG laser treatment alone (Er group), and the third group received combined treatment with Nd:YAG and Er:YAG lasers (NdErNd group). Microbiological samples, taken from the periodontal pockets at baseline and 6 months after treatments, were assessed with PET Plus tests. The combined NdErNd laser (93.0%), followed closely by Er:YAG laser (84.9%), treatment resulted in the highest reduction of all bacteria count after 6 months, whereas SRP (46.2%) failed to reduce Treponema denticola, Peptostreptococcus micros, and Capnocytophaga gingivalis. Full-mouth plaque and bleeding on probing scores dropped after 6 months and were the lowest in both laser groups. The combination of NdErNd resulted in higher probing pocket depth reduction and gain of clinical attachment level (1.99 ± 0.23 mm) compared to SRP (0.86 ± 0.13 mm) or Er:YAG laser alone (0.93 ± 0.20 mm) in 4-6 mm-deep pockets. Within their limits, the present results provide support for the combination of Nd:YAG and Er:YAG lasers to additionally improve the microbiological and clinical outcomes of nonsurgical periodontal therapy in patients with moderate to severe chronic periodontitis.

  5. Healing of rat mouth mucosa after irradiation with CO2, Nd:YAG, and CO2-Nd:YAG combination lasers.

    PubMed

    Luomanen, M; Rauhamaa-Mäkinen, R; Meurman, J H; Kosloff, T; Tiitta, O

    1994-08-01

    The healing process of wounds made by a combination laser was studied in 90 rats. The laser system enabled both separate and combined use of CO2 and Nd:YAG laser irradiations. The laser wounds and the control excision wounds made by alligator forceps appeared on both sides of the tongue. Specimens from the wound sites were taken immediately, 6 h, and 1, 2, 4, 7, 11, 21, 28, and 42 days after surgery. The wound-healing process was studied by macroscopic evaluation before preparing the specimens for light microscopy. Some differences were noted in the wound-healing process among the three groups into which the experimental animals were divided. Tissue coagulation damage was most extensive in the Nd:YAG laser sites, where it was observed in its full extent 4 days after surgery. Epithelial cells were seen to begin to proliferate in all the wounds 6 h after surgery. Re-epithelialization was completed by between 7 (CO2) and 21 days (Nd:YAG) at all the wound sites. The inflammatory cell infiltration was more prominent in the Nd:YAG and the CO2-Nd:YAG combination laser wounds than in the CO2 and excision wounds during healing. Tissue regeneration occurred faster with less contraction in the combination CO2-Nd:YAG wounds than in Nd:YAG wounds. The best macroscopic healing result was seen in the CO2 wound sites. The combination laser was effective both at cutting and at coagulating tissue. Combining the CO2 and Nd:YAG laser irradiation into one beam resulted in a greater incision depth than what could have been expected from using the two lasers separately.

  6. Quenching And Luminescence Efficiency Of Nd3+ In YAG

    NASA Astrophysics Data System (ADS)

    Lupei, Voicu; Lupei, Aurelia; Georgescu, Serban; Ionescu, Christian I.; Yen, William M.

    1989-05-01

    The effect of the concentration luminescence quenching of the 4F 3/2, level of Nd3+ in YAG on the relative efficiency is presented. Based on the analysis of the decay curves in terms of the energy transfer theory, an analytical expression for the relative luminescence efficiency is obtained. In the low concentration range (up to q,1.5 at % Nd3+), the efficiency linearly decreases when Nd3+ concentration increases. It is also stressed that pairs quenching contribute about 20 % to the nonradiative energy transfer losses. Quantum efficiency of luminescence is an important parameter for the characterization of laser active media; its lowering is due to either multiphonon relaxation or energy transfer processes. The multiphonon non-radiative probability depends on the energy gap between levels, on the phonon energy and temperature; usually at low activator doping it is practically independent on concentration. On the other hand, energy transfer losses show a marked dependence on activator concentration, a fact that severely limits the range of useful con-centration of active centers in some laser crystals. In the YAG:Nd case the minimum energy gap between the Stark components of the 4F,I.) and the next lower level 4F15/2 is of about 4700 cm-1. Since in YAG tree phonons most effdbtively coupled to the Rare pi.th ions have an energy of 1, 700 cm-1, the probability for multiphonon relaxation from the 'F3/, level, even at room temperature, is very low and therefore for low Nd 3+ concentrations quantum efficiency is expected to be close to 1.

  7. 20 mJ, 1 ps Yb:YAG Thin-disk Regenerative Amplifier

    PubMed Central

    Alismail, Ayman; Wang, Haochuan; Brons, Jonathan; Fattahi, Hanieh

    2017-01-01

    This is a report on a 100 W, 20 mJ, 1 ps Yb:YAG thin-disk regenerative amplifier. A homemade Yb:YAG thin-disk, Kerr-lens mode-locked oscillator with turn-key performance and microjoule-level pulse energy is used to seed the regenerative chirped-pulse amplifier. The amplifier is placed in airtight housing. It operates at room temperature and exhibits stable operation at a 5 kHz repetition rate, with a pulse-to-pulse stability less than 1%. By employing a 1.5 mm-thick beta barium borate crystal, the frequency of the laser output is doubled to 515 nm, with an average power of 70 W, which corresponds to an optical-to-optical efficiency of 70%. This superior performance makes the system an attractive pump source for optical parametric chirped-pulse amplifiers in the near-infrared and mid-infrared spectral range. Combining the turn-key performance and the superior stability of the regenerative amplifier, the system facilitates the generation of a broadband, CEP-stable seed. Providing the seed and pump of the optical parametric chirped-pulse amplification (OPCPA) from one laser source eliminates the demand of active temporal synchronization between these pulses. This work presents a detailed guide to set up and operate a Yb:YAG thin-disk regenerative amplifier, based on chirped-pulse amplification (CPA), as a pump source for an optical parametric chirped-pulse amplifier. PMID:28745636

  8. Comparative morphological investigation on the rabbit's auricle after exposure to CO2- and Nd:YAG-laser radiation.

    PubMed

    Wandhöfer, A; Bally, G; Kauffmann, G; Karduck, A

    1977-10-31

    By comparing the effects of CO2- and Nd:YAG-laser radiation (mainly differing in wave-length by a factor of 10), a surgical instrument suitable for Otorhinolaryngology had to be found. The studies were performed on the rabbit's auricle in order to examine the effect of the laser irradiation mainly on the cartilage. The CO2-laser was found to be more efficient in cutting and caused less extended tissue damage than the Nd:YAG-laser. The latter seems to be more suitable for soft tissue surgery.

  9. Association of Er:YAG and Nd:YAG irradiation for apicoectomy and retrofilling cavity preparation compared to conventional technique: a permeability study

    NASA Astrophysics Data System (ADS)

    Camargo, Selma C. C.; Gavini, Giulio; Eduardo, Carlos d. P.; Aun, Carlos E.; Ribeiro, Luciano W.; Coil, Jeffrey M.

    1999-05-01

    The aim of this research was to evaluate dentin permeability effects at the apical cut surface prepared with Er:YAG laser and irradiated with Nd:YAG laser compared to conventional techniques. 62 extracted human teeth were divided into four groups of 7 teeth each. For Group 1 apicoectomy was performed using high speed handpiece and diamond burs. Group 2 was prepared as group 1 and lased with Nd:YAG (1W,15Hz of energy before retrograde cavity filling). For group 3 Er:YAG* laser irradiation (wavelength of 2.94μm, pulse width of 250-500μs)was used in 400mJ of energy, frequency of 6Hz, on focus mode under distilled water refrigeration and group 4 was performed as group 3 and lased with Nd:YAG (1W, 15Hz of energy before retrograde cavity filling). Permeability was evaluated by the extent of methylene blue dye penetration into the tubules. There were statistically significant differences in permeability between groups. Nd:YAG laser irradiation significantly reduced apical dentin permeability when compared to unlased groups. Er:YAG laser by itself showed higher percentage of dye penetration.

  10. Transition of Emission Colours as a Consequence of Heat-Treatment of Carbon Coated Ce3+-Doped YAG Phosphors

    PubMed Central

    Yin, Liang-Jun; Dierre, Benjamin; Sekiguchi, Takashi; van Ommen, J. Ruud; Hintzen, Hubertus T. (Bert); Cho, Yujin

    2017-01-01

    To modify the luminescence properties of Ce3+-doped Y3Al5O12 (YAG) phosphors, they have been coated with a carbon layer by chemical vapor deposition and subsequently heat-treated at high temperature under N2 atmosphere. Luminescence of the carbon coated YAG:Ce3+ phosphors has been investigated as a function of heat-treatment at 1500 and 1650 °C. The 540 nm emission intensity of C@YAG:Ce3+ is the highest when heated at 1650 °C, while a blue emission at 400–420 nm is observed when heated at 1500 °C but not at 1650 °C. It is verified by X-ray diffraction (XRD) that the intriguing luminescence changes are induced by the formation of new phases in C@YAG:Ce3+-1500 °C, which disappear in C@YAG:Ce3+-1650 °C. In order to understand the mechanisms responsible for the enhancement of YAG:Ce3+ emission and the presence of the blue emission observed for C@YAG:Ce3+-1500 °C, the samples have been investigated by a combination of several electron microscopy techniques, such as HRTEM, SEM-CL, and SEM-EDS. This local and cross-sectional analysis clearly reveals a gradual transformation of phase and morphology in heated C@YAG:Ce3+ phosphors, which is related to a reaction between C and YAG:Ce3+ in N2 atmosphere. Through reaction between the carbon layer and YAG host materials, the emission colour of the phosphors can be modified from yellow, white, and then back to yellow under UV excitation as a function of heat-treatment in N2 atmosphere. PMID:29035336

  11. Transition of Emission Colours as a Consequence of Heat-Treatment of Carbon Coated Ce3+-Doped YAG Phosphors.

    PubMed

    Yin, Liang-Jun; Dierre, Benjamin; Sekiguchi, Takashi; van Ommen, J Ruud; Hintzen, Hubertus T Bert; Cho, Yujin

    2017-10-16

    To modify the luminescence properties of Ce 3+ -doped Y₃Al₅O 12 (YAG) phosphors, they have been coated with a carbon layer by chemical vapor deposition and subsequently heat-treated at high temperature under N₂ atmosphere. Luminescence of the carbon coated YAG:Ce 3+ phosphors has been investigated as a function of heat-treatment at 1500 and 1650 °C. The 540 nm emission intensity of C@YAG:Ce 3+ is the highest when heated at 1650 °C, while a blue emission at 400-420 nm is observed when heated at 1500 °C but not at 1650 °C. It is verified by X-ray diffraction (XRD) that the intriguing luminescence changes are induced by the formation of new phases in C@YAG:Ce 3+ -1500 °C, which disappear in C@YAG:Ce 3+ -1650 °C. In order to understand the mechanisms responsible for the enhancement of YAG:Ce 3+ emission and the presence of the blue emission observed for C@YAG:Ce 3+ -1500 °C, the samples have been investigated by a combination of several electron microscopy techniques, such as HRTEM, SEM-CL, and SEM-EDS. This local and cross-sectional analysis clearly reveals a gradual transformation of phase and morphology in heated C@YAG:Ce 3+ phosphors, which is related to a reaction between C and YAG:Ce 3+ in N₂ atmosphere. Through reaction between the carbon layer and YAG host materials, the emission colour of the phosphors can be modified from yellow, white, and then back to yellow under UV excitation as a function of heat-treatment in N₂ atmosphere.

  12. Comparative research on medicine application with 0.53-um, 1.06-um, and 1.32-um Nd:YAG lasers

    NASA Astrophysics Data System (ADS)

    Li, Yahua; Li, Zhenjia; Zhu, Changhong; Huang, Yizhong

    1996-09-01

    Because of its high power and excellent optical features, laser has almost been applied to everywhere of medical research and clinic. Over the past several years, laser medical has achieved a rapid progress, and laser medical instruments has developed promptly, each new wavelength can be successfully applied in diagnostic and treatment of diseases. Among the medical lasers, Nd:YAG solid-state laser systems have proven useful in surgical use operate, such as neurosurgery, gastroenterology, cardioangiology, urology, gynecology, dermatology and ENT. As with other solid-state lasers, the Nd:YAG laser can be made to emit various wavelengths by means of suitable resonator configurations and some newest solid-state laser technology, pumped by the Krypton lamp, the Nd:YAG laser at room temperature exhibits transition at 1.06 micrometer Nd:YAG, using nonlinear crystal and Q-switch to double its frequency can attain 0.53 micrometer green beam. In our laser systems, the efficiency at 1.06 micrometer is more than 3 percent, an efficiency of 0.5 percent at 1.32 micrometer and 0.53 micrometer can be attained. For a power of 100w at 1.06 micrometer, 15w at 1.32 micrometer and 0.53 micrometer can therefore be produced. All of three kinds Nd:YAG laser hold these characteristics: high output power; optical fiber transition that can be cooperated with endoscope. The paper mainly discusses laser operating characteristics and clinic applications of three kinds wavelengths at 0.53 micrometer 1.06 micrometer and 1.32 micrometer Nd:YAG laser systems.

  13. A flux-free method for synthesis of Ce{sup 3+}-doped YAG phosphor for white LEDs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qiang, Yaochun; Yu, Yuxi, E-mail: yu_heart@xmu.edu.cn; Chen, Guolong

    2016-02-15

    Highlights: • A series of CeF{sub 3}-doped YAG phosphors were successfully synthesized. • CeF{sub 3} not only can be used as the Ce{sup 3+} source but also can play the role of a flux. • The QY of YAG:CeF{sub 3} phosphor is 91% but the QY of YAG:Ce{sub 2}O{sub 3} phosphor is just 80%. • YAG:CeF{sub 3} phosphor exhibits excellent thermal stability. • Using CeF{sub 3} as the Ce{sup 3+} source is a promising flux-free method to prepare YAG:Ce{sup 3+}. - Abstract: A series of CeF{sub 3}-doped Y{sub 3}Al{sub 5}O{sub 12} (YAG:CeF{sub 3}) phosphor, CeO{sub 2}-doped Y{sub 3}Al{sub 5}O{sub 12}more » (YAG:Ce{sub 2}O{sub 3}) phosphor and 5 wt% BaF{sub 2} added YAG:Ce{sub 2}O{sub 3} (YAG:Ce{sub 2}O{sub 3} + BaF{sub 2}) phosphor were successfully synthesized by a solid-state reaction method. The microstructure, morphology, luminescence spectra, luminescence quantum yield (QY) and thermal quenching of the phosphors were investigated. The QY of YAG:CeF{sub 3} phosphor is 91% but the QY of YAG:Ce{sub 2}O{sub 3} phosphor is just 80%. At 150 °C, the luminescence intensity of YAG:CeF{sub 3} phosphor, YAG:Ce{sub 2}O{sub 3} phosphor and YAG:Ce{sub 2}O{sub 3} + BaF{sub 2} phosphor was 85%, 86% and 89% of that measured at 25 °C, respectively. The comprehensive performance of the white LED lamp employing YAG:CeF{sub 3} phosphor is even better than that of the white LED lamp employing YAG:Ce{sub 2}O{sub 3} + BaF{sub 2} phosphor. The experimental results show that it is a promising flux-free method to synthesize Ce{sup 3+}-doped YAG phosphor by employing CeF{sub 3} as the Ce{sup 3+} source.« less

  14. Clinical comparison of potassium-titanyl-phosphate (KTP) versus neodymium:YAG (Nd:YAG) laser treatment for lower extremity telangiectases.

    PubMed

    Ozden, Müge Güler; Bahçivan, Muzaffer; Aydin, Fatma; Şentürk, Nilgün; Bek, Yüksel; Cantürk, Tayyar; Turanli, Ahmet Yaşar

    2011-06-01

    The Nd:YAG laser has been considered the gold standard of treatment for leg veins, but pain and side effects have fueled physicians to use treatment alternatives. To compare the clinical efficacy of the long-pulsed 1064-nm Nd:YAG laser with KTP laser irradiation in the treatment of leg telangiectasia. A series of 16 patients with size-matched superficial telangiectases of the lower extremities were randomly assigned to receive three consecutive monthly treatments with the long-pulsed 1064-nm Nd:YAG on one leg and 532-nm KTP laser irradiation on the other. For the 16 patients who completed the study, 64 leg vein sites were treated. Average clinical improvement scores were 1.94 and 1.25 for the KTP laser-treated leg and 3.38 and 3.50 for the Nd:YAG laser-treated leg with thin (≤ 1 mm) and large (1-3 mm) vessels, respectively. After the third treatment session, average improvement scores of 2.44, 1.31 and 3.75, 3.23 were given for the KTP and Nd:YAG laser-treated sides, respectively. Both the 1064-nm Nd:YAG and KTP lasers are effective in the treatment of lower extremity telangiectases. However, the KTP laser has very low efficacy with vessels larger than 1 mm and should not be elected when treating such vessels.

  15. Effect of CO2, Nd:YAG and Er:YAG Lasers on Microtensile Bond Strength of Composite to Bleached-Enamel.

    PubMed

    Basir, Mahshid Mohammadi; Rezvani, Mohammad Bagher; Chiniforush, Nasim; Moradi, Zohreh

    2016-01-01

    Tooth restoration immediately after bleaching is challenging due to the potential problems in achieving adequate bond strength. The aim of this study was to evaluate the effect of surface treatment with ER:YAG, ND:YAG, CO2 lasers and 10% sodium ascorbate solution on immediate microtensile bond strength of composite resin to recently bleached enamel. Ninety sound molar teeth were randomly divided into three main groups (n:30) : NB (without bleaching), HB (bleached with 38% carbamide peroxide) and OB (bleached with Heydent bleaching gel assisted by diode laser). Each group was divided into five subgroups (n:6) : Si (without surface treatment), Er (Er:YAG laser), CO2 (CO2 laser), Nd (Nd:YAG laser) and As (Immersion in 10% sodium ascorbate solution). The bonding system was then applied and composite build-ups were constructed. The teeth were sectioned by low speed saw to obtain enamel- resin sticks and submitted to microtensile bond testing. Statistical analyses were done using two- way ANOVA, Tukey and Tamhane tests. µTBS of bleached teeth irradiated with ND:YAG laser was not significantly different from NB-Nd group. Microtensile bond strength of OB-Er group was higher than NB-Er and HB-Er groups. The mean µTBS of HB-CO2 group was higher than NB-CO2 group; the average µTBS of HB-As and OB-As groups was also higher than NB-As group. Use of Nd:YAG, CO2 lasers and 10% sodium ascorbate solution could improve the bond strength in home-bleached specimens. Application of ND:YAG laser on nonbleached specimens and Er:YAG laser on office-bleached specimens led to the highest µTBS in comparison to other surface treatments in each main group.

  16. Habit modification of bis-thiourea zinc chloride (ZTC) semi organic crystals by impurities.

    PubMed

    Ruby Nirmala, L; Thomas Joseph Prakash, J

    2013-06-01

    Single crystals of bis-thiourea zinc chloride (ZTC) doped with metal ion (Li(+)) possess excellent nonlinear optical properties. These crystals were grown by slow evaporation solution growth technique. The effect of Li(+) dopant on the growth and properties of ZTC single crystal were investigated and reported. The grown crystals were crystallized in orthorhombic structure with non-centro symmetric space group Pn21a through the parent compound. The amount of dopant incorporated in the parent crystal was revealed by the inductively coupled plasma (ICP-OES) studies. The FT-IR spectroscopy study was done for finding and confirming the functional groups present in the compound. The UV-Visible spectral study was carried out to find the optical behavior and transparency nature of the grown crystal. TG/DTA measurements and Vickers microhardness measurements were traced to find out the thermal and mechanical stability of the grown crystals respectively. Using Nd:YAG laser, the Second harmonic generation (SHG) for the grown crystals were confirmed. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Experimental Investigation of Orthoenstatite Single Crystal Rheology

    NASA Astrophysics Data System (ADS)

    fraysse, G.; Girard, J.; Holyoke, C. W.; Raterron, P.

    2013-12-01

    The plasticity of enstatite, upper mantle second most abundant mineral, is still poorly constrained, mostly because of its high-temperature (T) transformation into proto- and clino-enstatite at low pressure (P). Mackwell (1991, GRL, 18, 2027) reports a pioneer study of protoenstatite (Pbcn) single-crystal rheology, but the results do not directly apply to the orthorhombic (Pbca) mantle phase. Ohuchi et al. (2011, Contri. Mineral. Petrol , 161, 961) carried out deformation experiments at P=1.3 GPa on oriented orthoenstatite crystals, investigating the activity of [001](100) and [001](010) dislocation slip systems; they report the first rheological laws for orthoenstatite crystals. However, strain and stress were indirectly constrained in their experiments, which questioned whether steady state conditions of deformation were achieved. Also, data reported for [001](100) slip system were obtained after specimens had transformed by twinning into clinoenstatite. We report here new data from deformation experiments carried out at high T and P ranging from 3.5 to 6.2 GPa on natural Fe-bearing enstatite single crystals, using the Deformation-DIA apparatus (D-DIA) that equipped the X17B2 beamline of the NSLS (NY, USA). The applied stress and specimen strain rates were measured in situ by X-ray diffraction and imaging techniques (e.g., Raterron & Merkel, 2009, J. Sync. Rad., 16, 748; Raterron et al., 2013, Rev. Sci. Instr., 84, 043906). Three specimen orientations were tested: i) with the compression direction along [101]c crystallographic direction, which forms a 45° angle with both [100] and [001] axes, to investigate [001](100) slip-system activity; ii) along [011]c direction to investigate [001](010) system activity; iii) and along enstatite [125] axis, to activate both slip systems together. Crystals were deformed two by two, to compare slip system activities, or against enstatite aggregates or orientated olivine crystals of known rheology for comparison. Run products

  18. Cascade conical refraction for annular pumping of a vortex Nd:YAG laser and selective excitation of low- and high-order Laguerre–Gaussian modes

    NASA Astrophysics Data System (ADS)

    Wu, Yongxiao; Wang, Zhongyang; Chen, Sanbin; Shirakwa, Akira; Ueda, Ken-ichi; Li, Jianlang

    2018-05-01

    We proposed an efficient and vortex Nd:YAG laser for selective lasing of low- and high-order vortex modes, in which multiple-ring pump light was originated from cascaded conical refraction of multiple biaxial crystals. In our proof of concept demonstration, we used two-crystal cascade conical refraction to generate two-ring pump light; the mutual intensity ratio and relative separation of the inner ring and outer ring were controlled by rotating the second biaxial crystal and by moving the imaging lens, respectively. As a result, we obtained selective excitation of Laguerre–Gaussian (LG01 and LG03) vortex modes in the end-pump Nd:YAG laser. For LG01-mode output, the laser power reached 439 mW with 52.5% slope efficiency; for LG03-mode output, the laser power reached 160 mW with 41.3% slope efficiency. Our results revealed that the multiple-ring pumping technique based on cascaded conical refraction would pave the way for realization of the efficient and switchable excitation of low- and high-order LG modes in an end-pumped solid-state laser.

  19. Er:YAG and CTH:YAG laser radiation: contact versus non-contact enamel ablation and sonic-activated bulk composite placement

    NASA Astrophysics Data System (ADS)

    Buckova, M.; Kasparova, M.; Dostalova, T.; Jelinkova, H.; Sulc, J.; Nemec, M.; Fibrich, M.; Bradna, P.; Miyagi, M.

    2013-05-01

    Laser radiation can be used for effective caries removal and cavity preparation without significant thermal effects, collateral damage of tooth structure, or patient discomfort. The aim of this study was to compare the quality of tissue after contact or non-contact Er:YAG and CTH:YAG laser radiation ablation. The second goal was to increase the sealing ability of hard dental tissues using sonic-activated bulk filling material with change in viscosity during processing. The artificial caries was prepared in intact teeth to simulate a demineralized surface and then the Er:YAG or CTH:YAG laser radiation was applied. The enamel artificial caries was gently removed by the laser radiation and sonic-activated composite fillings were inserted. A stereomicroscope and then a scanning electron microscope were used to evaluate the enamel surface. Er:YAG contact mode ablation in enamel was quick and precise; the cavity was smooth with a keyhole shaped prism and rod relief arrangement without a smear layer. The sonic-activated filling material was consistently regularly distributed; no cracks or microleakage in the enamel were observed. CTH:YAG irradiation was able to clean but not ablate the enamel surface; in contact and also in non-contact mode there was evidence of melting and fusing of the enamel.

  20. Injection seeded, diode pumped regenerative ring Nd:YAG amplifier for spaceborne laser ranging technology development

    NASA Technical Reports Server (NTRS)

    Coyle, D. Barry; Kay, Richard B.; Degnan, John J.; Krebs, Danny J.; Seery, Bernard D.

    1992-01-01

    A small, all solid state, regenerative ring amplifier designed as a prototype for space application is discussed. Novel features include dual side pumping of the Nd:YAG crystal and a triangular ring cavity design which minimizes the number of optical components and losses. The amplifier is relatively small (3 ns round trip time) even though standard optical elements are employed. The ring regeneratively amplifies a 100 ps single pulse by approximately 10(exp 5) at a repetition rate of 10 to 100 Hz. The amplifier is designed to be injection seeded with a pulsed, 100 ps laser diode at 1.06 microns, but another Nd:YAG laser system supplying higher pulse energies was employed for laboratory experiment. This system is a prototype laser oscillator for the Geoscience Laser Ranging System (GLRS) platform. Results on measurements of beam quality, astigmatism, and gain are given.

  1. A protected annealing strategy to enhanced light emission and photostability of YAG:Ce nanoparticle-based films.

    PubMed

    Revaux, Amelie; Dantelle, Geraldine; George, Nathan; Seshadri, Ram; Gacoin, Thierry; Boilot, Jean-Pierre

    2011-05-01

    A significant obstacle in the development of YAG:Ce nanoparticles as light converters in white LEDs and as biological labels is associated with the difficulty of finding preparative conditions that allow simultaneous control of structure, particle size and size distribution, while maintaining the optical properties of bulk samples. Preparation conditions frequently involve high-temperature treatments of precursors (up to 1400 °C), which result in increased particle size and aggregation, and lead to oxidation of Ce(iii) to Ce(iv). We report here a process that we term protected annealing, that allows the thermal treatment of preformed precursor particles at temperatures up to 1000 °C while preserving their small size and state of dispersion. In a first step, pristine nanoparticles are prepared by a glycothermal reaction, leading to a mixture of YAG and boehmite crystalline phases. The preformed nanoparticles are then dispersed in a porous silica. Annealing of the composite material at 1000 °C is followed by dissolution of the amorphous silica by hydrofluoric acid to recover the annealed particles as a colloidal dispersion. This simple process allows completion of YAG crystallization while preserving their small size. The redox state of Ce ions can be controlled through the annealing atmosphere. The obtained particles of YAG:Ce (60 ± 10 nm in size) can be dispersed as nearly transparent aqueous suspensions, with a luminescence quantum yield of 60%. Transparent YAG:Ce nanoparticle-based films of micron thickness can be deposited on glass substrates using aerosol spraying. Films formed from particles prepared by the protected annealing strategy display significantly improved photostability over particles that have not been subject to such annealing. © The Royal Society of Chemistry 2011

  2. Scanning electron microscopy investigation of PMMA removal by laser irradiation (Er:YAG) in comparison with an ultrasonic system and curettage in hip joint revision arthroplasty.

    PubMed

    Birnbaum, Klaus; Gutknecht, Norbert

    2010-07-01

    The cement often left in the femur socket during hip joint revision arthroplasty is usually removed by curettage. Another method for removing the cement is to use an ultrasonic system, and yet another alternative may be to use a laser system. The aim of these investigations was to determine the pulse rate and pulse energy of the Er:YAG laser for sufficient cement ablation. We also compared the results obtained using the laser with those obtained using an ultrasonic device or curettage by histological and scanning electron microscopy (SEM) investigation of the border zone between the polymethyl methacrylate (PMMA) and unfixed specimens of femoral bone. Therefore we prepared 30 unfixed human femur stems after hip joint replacement and prepared ten sagittal sections from each femur stem (in total 300 sections). Of these 300 specimens, 180 were treated with the Er:YAG laser, 60 with the ultrasonic system and 60 by curettage. The high pulse energy of 500 mJ and a pulse rate of 4 Hz provided the highest PMMA ablation rate, although the boundary surface between PMMA and femoral bone was not as fine-grained as found in samples treated at 15 Hz and 250 mJ. However, the treatment time for the same cement ablation rate with the latter settings was twice that at 4 Hz and 500 mJ. Compared to the boundary surfaces treated with the ultrasonic device or curettage, the laser-treated samples had a more distinct undifferentiated boundary surface between PMMA and femoral bone. After development of the Er:YAG-laser to provide higher pulse energies, it may in the future be an additional efficient method for the removal of PMMA in revision arthroplasty. The Er:YAG laser should be combined with an endoscopic and a rinsing suction system so that PMMA can be removed from the femoral shaft under direct vision.

  3. Generation of orthogonally polarized self-mode-locked Nd:YAG lasers with tunable beat frequencies from the thermally induced birefringence.

    PubMed

    Sung, C L; Cheng, H P; Lee, C Y; Cho, C Y; Liang, H C; Chen, Y F

    2016-04-15

    The simultaneous self-mode-locking of two orthogonally polarized states in a Nd:YAG laser is demonstrated by using a short linear cavity. A total output power of 3.8 W can be obtained at an incident pump power of 8.2 W. The beat frequency Δfc between two orthogonally polarized mode-locked components is observed and measured precisely. It is found that the beat frequency increases linearly with an increase in the absorbed pump power. The origin of the beat frequency can be utterly manifested by considering the thermally induced birefringence in the Nd:YAG crystal. The present result offers a promising approach to generate orthogonally polarized mode-locked lasers with tunable beat frequency.

  4. [Development and medical application of Er-YAG laser].

    PubMed

    Okamoto, Y; Kobayashi, A; Awazu, A; Ogino, H; Ban, T

    1993-09-01

    Result of developments of Er-YAG laser and its delivery system were reported. Er-YAG laser's wavelength is 2.94 microns, the beam absorption rate by water is higher than other laser beam. Er-YAG laser has repeated pulse oscillation, pulse width is 400 mu, sec, the repeat frequency is between 5 to 10 pulse per second. The mean power is 4 W maximum, 10 pps. The fibers of laser are made of zirconium-F-glass. We carried out a study on the possible application of the Er-YAG laser on the rabbit arteries and myocardium and human arteries were examined in vitro. Very clear cuts were observed on the histological examination. There were no evidence of thermal damage, no carbonization on the sharp cutting surface. Experimental result showed that Er-YAG lasers had good potential for angioplastic laser.

  5. An intra-cavity pumped dual-wavelength laser operating at 946 nm and 1064 nm with Nd:YAG  +  Nd:YVO4 crystals

    NASA Astrophysics Data System (ADS)

    He-Dong, Xiao; Yuan, Dong; Yu, Liu; Shu-Tao, Li; Yong-Ji, Yu; Guang-Yong, Jin

    2016-09-01

    We adopt a compact intra-cavity pumped structure of Nd:YAG and Nd:YVO4 crystals to develop an efficient dual-wavelength laser that operates at 946 nm and 1064 nm. A 808 nm laser diode is used to pump the Nd:YAG crystal, which emits at 946 nm, and the Nd:YVO4 crystal, which emits at 1064 nm, is intra-cavity pumped at 946 nm. In order to avoid unnecessary pump light passing though the Nd:YAG crystal, reaching the Nd:YVO4 crystal and having an impact on the cavity pump, the two crystals are placed as far from one another as possible in this experiment. The output power at 1064 nm can be adjusted from 1 W-2.9 W by varying the separation between the two crystals. A total output power of 4 W at the dual-wavelengths is achieved at an incident pump power of 30.5 W, where the individual output powers for the 946 nm and 1064 nm emissions are 1.1 W and 2.9 W, respectively.

  6. Application of the holmium:YAG laser for prostatectomy.

    PubMed

    Kabalin, J N; Gilling, P J; Fraundorfer, M R

    1998-02-01

    The authors review the current knowledge regarding the application of the Holmium: YAG laser for prostatectomy. Conventional surgical therapies for benign prostatic hyperplasia (BPH) are effective but associated with relatively high morbidity. Laser prostatectomy, using either Neodymium:YAG or potassium-titanyl-phosphate lasers, has emerged as a new and much safer operative approach to relieve symptoms of benign prostatic hyperplasia. However, these laser wavelengths possess key disadvantages that have limited their acceptability and dissemination in everyday urologic practice. THE authors review their own extensive experience in the development of clinical application of Holmium: YAG laser technology for prostatectomy, as well as the published reports in the current medical literature now dealing with this subject. In multiple clinical trials, Holmium:YAG laser resection of the prostate has proven efficacious in relieving symptomatic BPH. Both objective urodynamic measures of voiding outcomes and symptomatic improvement have been shown to be equivalent to standard electrocautery resection of the prostate. At the same time, these studies have demonstrated the superior safety and hemostasis of Holmium:YAG laser prostatectomy compared to electrocautery resection, similar to prior laser prostatectomy procedure. Unlike prior forms of laser prostatectomy, Holmium:YAG laser resection of the prostate acutely removes all obstructing prostate tissue, so that the postoperative catheterization requirement is typically only overnight and improvement in voiding is immediate. Current operative techniques and the latest technological developments to facilitate Holmium:YAG laser prostatectomy are described. Holmium: YAG laser prostatectomy combines the best features of prior laser prostatectomy technologies, including minimal complications and morbidity, with the efficacy and immediacy of voiding outcomes associated with conventional electrocautery resection of the prostate.

  7. Investigation of continuous wave and pulsed laser performance based on Nd3+:Gd0.6Y1.4SiO5 crystal

    NASA Astrophysics Data System (ADS)

    Feng, Chao; Liu, Zhaojun; Cong, Zhenhua; Shen, Hongbin; Li, Yongfu; Wang, Qingpu; Fang, Jiaxiong; Xu, Xiaodong; Xu, Jun; Zhang, Xingyu

    2015-12-01

    We systematically investigated a laser diode (LD) pumped Nd:GYSO (Nd3+:Gd0.6Y1.4SiO5) laser. The output power of the continuous wave laser was as high as 3.5 W with a slope efficiency of 31.8%. In the Q-switched operation; the laser exhibited dual-wavelengths output (1073.6 nm and 1074.7 nm) synchronously with a Cr4+:YAG as the saturable absorber (SA). Additionally, a passively mode-locked laser was demonstrated using a semiconductor SA mirror with a maximum average output power of 510 mW at a central wavelength of 1074 nm, while the pulse width of the laser was as short as 5 ps. Our experiment proved that the Nd:GYSO mixed crystal was a promising material for a solid-state laser.

  8. Characterization of caries progression on dentin after irradiation with Nd:YAG laser by FTIR spectroscopy and fluorescence imaging

    NASA Astrophysics Data System (ADS)

    Ana, P. A.; Brito, A. M. M.; Zezell, D. M.; Lins, E. C. C. C.

    2015-06-01

    Considering the use of high intensity lasers for preventing dental caries, this blind in vitro study evaluated the compositional and fluorescence effects promoted by Nd:YAG laser (λ=1064 nm) when applied for prevention of progression of dentin caries, in association or not with topical application of acidulated phosphate fluoride (APF). Sixty bovine root dentin slabs were prepared and demineralized by 32h in order to create early caries lesions. After, the slabs were distributed into six experimental groups: G1- untreated and not submitted to a pH-cycling model; G2- untreated and submitted to a pH-cycling model; G3- acidulated phosphate fluoride application (APF); G4- Nd:YAG irradiation (84.9 J/cm2, 60 mJ/pulse); G5- treated with Nd:YAG+APF; G6- treated with APF+Nd:YAG. After treatments, the samples of groups G2 to G6 were submitted to a 4-day pH-cycling model in order to simulate the progression of early caries lesions. All samples were characterized by the micro-attenuated total reflection technique of Fourier transformed infrared spectroscopy (μATR-FTIR), using a diamond crystal, and by a fluorescence imaging system (FIS), in which it was used an illuminating system at λ= 405±30 nm. Demineralization promoted reduction in carbonate and phosphate contents, exposing the organic matter; as well, it was observed a significant reduction of fluorescence intensity. Nd:YAG laser promoted additional chemical changes, and increased the fluorescence intensity even with the development of caries lesions. It was concluded that the compositional changes promoted by Nd:YAG, when associated to APF, are responsible for the reduction of demineralization progression observed on root dentin.

  9. Ignition of an automobile engine by high-peak power Nd:YAG/Cr⁴⁺:YAG laser-spark devices.

    PubMed

    Pavel, Nicolaie; Dascalu, Traian; Salamu, Gabriela; Dinca, Mihai; Boicea, Niculae; Birtas, Adrian

    2015-12-28

    Laser sparks that were built with high-peak power passively Q-switched Nd:YAG/Cr(4+):YAG lasers have been used to operate a Renault automobile engine. The design of such a laser spark igniter is discussed. The Nd:YAG/Cr(4+):YAG laser delivered pulses with energy of 4 mJ and 0.8-ns duration, corresponding to pulse peak power of 5 MW. The coefficients of variability of maximum pressure (COV(Pmax)) and of indicated mean effective pressure (COV(IMEP)) and specific emissions like hydrocarbons (HC), carbon monoxide (CO), nitrogen oxides (NO(x)) and carbon dioxide (CO2) were measured at various engine speeds and high loads. Improved engine stability in terms of COV(Pmax) and COV(Pmax) and decreased emissions of CO and HC were obtained for the engine that was run by laser sparks in comparison with classical ignition by electrical spark plugs.

  10. Effect of Nd:YAG laser on the solvent evaporation of adhesive systems.

    PubMed

    Batista, Graziela Ribeiro; Barcellos, Daphne Câmara; Rocha Gomes Torres, Carlos; Damião, Álvaro José; de Oliveira, Hueder Paulo Moisés; de Paiva Gonçalves, Sérgio Eduardo

    2015-01-01

    This study evaluated the influence of Nd:YAG laser on the evaporation degree (ED) of the solvent components in total-etch and self-etch adhesives. The ED of Gluma Comfort Bond (Heraeus-Kulzer) one-step self-etch adhesive, and Adper Single Bond 2 (3M ESPE), and XP Bond (Dentsply) total-etch adhesives was determined by weight alterations using two techniques: Control--spontaneous evaporation of the solvent for 5 min; Experimental--Nd:YAG laser irradiation for 1 min, followed by spontaneous evaporation for 4 min. The weight loss due to evaporation of the volatile components was measured at baseline and after 10 s, 20 s, 30 s, 40 s, 50 s, 60 s, 70 s, 80 s, 90 s, 100 s, 110 s, 2 min, 3 min, 4 min, and 5 min. Evaporation of solvent components significantly increased with Nd:YAG laser irradiation for all adhesives investigated. Gluma Comfort Bond showed significantly higher evaporation of solvent components than Adper Single Bond 2 and XP Bond. All the adhesives lost weight quickly during the first min of Nd:YAG laser irradiation. The application of Nd:YAG laser on adhesives before light curing had a significant effect on the evaporation of the solvent components, and the ED of Gluma Comfort Bond one-step self-etch adhesive was significantly higher than with Adper Single Bond 2 and XP Bond total-etch adhesives. The use of the Nd:YAG laser on the uncured adhesive technique can promote a greater ED of solvents, optimizing the longevity of the adhesive restorations.

  11. Two-dimensional microsphere quasi-crystal: fabrication and properties

    NASA Astrophysics Data System (ADS)

    Noginova, Natalia E.; Venkateswarlu, Putcha; Kukhtarev, Nickolai V.; Sarkisov, Sergey S.; Noginov, Mikhail A.; Caulfield, H. John; Curley, Michael J.

    1996-11-01

    2D quasi-crystals were fabricated from polystyrene microspheres and characterized for their structural, diffraction, and non-linear optics properties. The quasi- crystals were produced with the method based on Langmuir- Blodgett thin film technique. Illuminating the crystal with the laser beam, we observed the diffraction pattern in the direction of the beam propagation and in the direction of the back scattering, similar to the x-ray Laue pattern observed in regular crystals with hexagonal structure. The absorption spectrum of the quasi-crystal demonstrated two series of regular maxima and minima, with the spacing inversely proportional to the microspheres diameter. Illumination of the dye-doped microspheres crystal with Q- switched radiation of Nd:YAG laser showed the enhancement of non-linear properties, in particular, second harmonic generation.

  12. Gingival melanin depigmentation by Er:YAG laser: A literature review.

    PubMed

    Pavlic, Verica; Brkic, Zlata; Marin, Sasa; Cicmil, Smiljka; Gojkov-Vukelic, Mirjana; Aoki, Akira

    2018-04-01

    Laser ablation is recently suggested as a most effective and reliable technique for depigmentation of melanin hyperpigmented gingiva. To date, different lasers have been used for gingival depigmentation (CO 2 , diode, Nd:YAG, Er:YAG and Er,Cr:YSGG lasers). The use of Er:YAG laser for depigmentation of melanin hyperpigmented gingiva has gained increasing importance in recent years. The purpose of this study was to report removal of gingival melanin pigmentation using an Er:YAG laser in a literature review. The main outcomes, such as improvement of signs (clinical parameters of bleeding, erythema, swelling and wound healing), symptoms (pain) and melanin recurrence/repigmentation were measured. The literature demonstrated that depigmentation of gingival melanin pigmentation can be performed safely and effectively by Er:YAG laser resulting in healing and an esthetically significant improvement of gingival discoloration. Thus, Er:YAG laser seems to be safe and useful in melanin depigmentation procedure. However, the main issue in giving the final conclusion of the optimal Er:YAG laser use in melanin depigmentation is that, to date, studies are offering completely discrepant Er:YAG laser procedure protocols (complex settings of laser parameters), and different criteria for the assessment of depigmentation and repigmentation (recurrence), thus hampering the comparison of the results. Therefore, further studies are necessary to give an optimal recommendation on the use of Er:YAG laser in gingival melanin hyperpigmentation.

  13. Spectroscopic study of gel grown L-Valine Zinc Glycine Thiourea Sulfate (VZGTS) crystal: A novel NLO crystal

    NASA Astrophysics Data System (ADS)

    Rathod, Kiran T.; Patel, I. B.

    2017-05-01

    In recent years, organometalic non linear optical (NLO) materials have attained immense appeal form researchers due to its range of technological applications in photonic field and optoelectronic technology. In present research work, novel semi organic NLO L-Valine Zinc Glycine Thiourea Sulfate crystals (VZGTS) with different morphologies were grown by gel method at ambient temperature. Presence and identification of functional groups were confirmed by FITR analysis. Spectroscopic studies were carried out for it. The UV-Vis spectroscopy is recorded for crystal. PL study stats that the crystal has insulating nature. Spectroscopic study shows that this crystal has good transparency in the case of fundamental wavelength of Nd : YAG laser. Second Harmonic Generation (SHG) efficiency was confirmed by Kurtz - Perry powder method. Results are discussed in the paper.

  14. Minimally invasive scoliosis treatment with a Ho:YAG laser

    NASA Astrophysics Data System (ADS)

    Rumpf, Christian G.; Lang, Robert D.; Goetz, Marcus H.

    2000-11-01

    Today most surgical treatment of spinal deformations is concentrated on invasive mechanical techniques with long operation times and major effects on the patient's mobility. The proposed minimally invasive technique using laser light for tissue ablation offers a possibility of gentle scoliosis treatment. It is thought that an early removal of the epiphysial growth zone on the convex side over several vertebrae results in a straightening of the spine. In a first evaluation, four different laser systems including argon ion, Nd:YAG (Q-switched), Nd:YAG (cw), and Ho:YAG laser were compared with respect to thermal damage to adjacent tissue, ablation rates, efficiency and laser handling. For in-vivo investigation, fresh lamb spine was used. Comparison showed that the Ho:YAG laser is the most appropriate laser for the given goal, providing efficient photoablation with moderate thermal effects on the adjacent tissue. In a second step the proposed minimally invasive operation technique was performed in in-vivo experiments on young foxhounds using 3D- thoracoscopic operation techniques. During these operations temperature mapping was done using fiber-optic fluorescent probes. After 12 months of normal growth the animals were sacrificed and x-ray as well as MRI was performed on the spine. First results show a positive effect of scoliotic growth in two cases. Being able to produce a scoliosis by hemiepiphysiodesis on the vertebra, It is thought that this technique is successful for a straightening of the spine on patients with scoliosis.

  15. The effect of Ce3+ concentration and heat treatment on the luminescence efficiency of YAG phosphor

    NASA Astrophysics Data System (ADS)

    Valiev, Damir; Han, Tao; Vaganov, Vitaly; Stepanov, Sergey

    2018-05-01

    Y3Al5O12 (YAG) phosphor powders doped with Ce3+ at different concentrations (YAG:xCe, x = 0.02, 0.04, 0.06, 0.08, 0.1 wt%) were synthesized by the solid-state reaction method with the addition of BaF2 flux. The effects of cerium concentration and heat treatment on the luminescence efficiency of the YAG:Ce3+ phosphor were investigated. The introduction of Ce3+ ions leads to an increase in luminescent intensity of the YAG phosphor at 560 nm. The band at 530 nm is attributed to Ce3+ ions (optical transitions from the 4f-5d excited state). We assumed that such an increase in the luminescent intensity is due to the ability of Ce3+ to act as a luminescence sensitizer of intrinsic defects in YAG phosphor. The analysis of luminescence decay kinetics in the investigated samples has shown that the decay time in all samples does not differ significantly and equals τ ≈ 60 ± 3 ns. We showed experimentally that increasing the luminescence intensity has an effect observed with relatively low temperature treatment (T = 400 K). The nature of possible luminescence centers and the effect of low heat treatment on the luminescence properties of the powders are discussed.

  16. Suppression of parasitic oscillations in a core-doped ceramic Nd:YAG laser by Sm:YAG cladding.

    PubMed

    Huss, Rafael; Wilhelm, Ralf; Kolleck, Christian; Neumann, Jörg; Kracht, Dietmar

    2010-06-07

    The onset of parasitic oscillations limits the extraction efficiency and therefore energy scaling of Q-switched lasers. A solid-state laser was end pumped with a fiber-coupled diode laser and operated in q-cw as well as in passively Q-switched operation. For Q-switched operation, we demonstrate the suppression of parasitic oscillations in a core-doped ceramic Nd:YAG laser by Sm:YAG cladding.

  17. Crystal growth, spectral, structural and optical studies of π-conjugated stilbazolium crystal: 4-bromobenzaldehyde-4'-N'-methylstilbazolium tosylate.

    PubMed

    Krishna Kumar, M; Sudhahar, S; Bhagavannarayana, G; Mohan Kumar, R

    2014-05-05

    Nonlinear optical (NLO) organic compound, 4-bromobenzaldehyde-4'-N'-methylstilbazolium tosylate was synthesized by reflux method. The formation of molecular complex was confirmed from (1)H NMR, FT-IR and FT-Raman spectral analyses. The single crystals were grown by slow evaporation solution growth method and the crystal structure and atomic packing of grown crystal was identified. The morphology and growth axis of grown crystal were determined. The crystal perfection was analyzed using high resolution X-ray diffraction study on (001) plane. Thermal stability, decomposition stages and melting point of the grown crystal were analyzed. The optical absorption coefficient (α) and energy band gap (E(g)) of the crystal were determined using UV-visible absorption studies. Second harmonic generation efficiency of the grown crystal was examined by Kurtz powder method with different particle size using 1064 nm laser. Laser induced damage threshold study was carried out for the grown crystal using Nd:YAG laser. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Growth and anisotropic thermal properties of biaxial Ho:YAlO3 crystal

    NASA Astrophysics Data System (ADS)

    Dong, Qin; Zhao, Guangjun; Chen, Jianyu; Ding, Yuchong; Zhao, Chengchun

    2010-07-01

    Ho:YAlO3 (YAP) crystal with large size and good optical quality has been grown by the Czochralski method. Thermal properties of the as-grown Ho:YAP crystal have been investigated by measuring the temperature-dependent, anisotropic thermal expansion, specific heat, thermal diffusion, and thermal conductivity. The results show that Ho:YAP crystal possesses a large anisotropic thermal expansion and good thermal conductivity. The calculated average thermal expansion coefficients along a, b, and c axis are αa=9.18×10-6/K, αb=1.94×10-6/K, and αc=7.61×10-6/K from 293.15 to 770.15 K. The thermal conductivities along a, b, and c axis are up to 11.6, 9.9, and 12.3 W m-1 K-1 at 298.15 K. Compared with Ho: Y3Al5O12 (YAG), Ho:YAP crystal has a larger thermal conductivity along a axis from 298.15 to 568.15 K.

  19. Theoretical and experimental investigations on high peak power Q-switched Nd:YAG laser at 1112 nm

    NASA Astrophysics Data System (ADS)

    He, Miao; Yang, Feng; Wang, Zhi-Chao; Gao, Hong-Wei; Yuan, Lei; Li, Chen-Long; Zong, Nan; Shen, Yu; Bo, Yong; Peng, Qin-Jun; Cui, Da-Fu; Xu, Zu-Yan

    2018-07-01

    We report on the experimental measurement and theoretical analysis on a Q-switched high peak power laser diode (LD) side-pumped 1112 nm Nd:YAG laser by means of special mirrors coating design in cavity. In theory, a numerical model, based on four-wavelength rate equations, is performed to analyze the competition process of different gain lines and the output characteristics of the Q-switched Nd:YAG laser. In the experiment, a maximum output power of 25.2 W with beam quality factor M2 of 1.46 is obtained at the pulse repetition rate of 2 kHz and 210 ns of pulse width, corresponding to a pulse energy and peak power of 12.6 mJ and 60 kW, respectively. The experimental data agree well with the theoretical simulation results.

  20. Solar-Pumped TEM₀₀ Mode Nd:YAG laser.

    PubMed

    Liang, Dawei; Almeida, Joana

    2013-10-21

    Here we show a significant advance in solar-pumped laser beam brightness by utilizing a 1.0 m diameter Fresnel lens and a 3 mm diameter Nd:YAG single-crystal rod. The incoming solar radiation is firstly focused by the Fresnel lens on a solar tracker. A large aspheric lens and a 2D-CPC concentrator are then combined to further compress the concentrated solar radiation along the thin laser rod within a V-shaped pumping cavity. 2.3 W cw TEM₀₀ (M² ≤ 1.1) solar laser power is finally produced, attaining 1.9 W laser beam brightness figure of merit, which is 6.6 times higher than the previous record. For multimode operation, 8.1 W cw laser power is produced, corresponding to 143% enhancement in collection efficiency.

  1. Polarized spectral properties and 1.5-1.6 μm laser operation of Er:Sr3Yb2(BO3)4 crystal

    NASA Astrophysics Data System (ADS)

    Lin, F. L.; Huang, J. H.; Chen, Y. J.; Gong, X. H.; Lin, Y. F.; Luo, Z. D.; Huang, Y. D.

    2013-10-01

    Undoped and Er3+-doped Sr3Yb2(BO3)4 crystals were grown by the Czochralski method. Room temperature polarized spectral properties of the Er:Sr3Yb2(BO3)4 crystal were investigated. The efficiency of the energy transfer from Yb3+ to Er3+ ions in this crystal was calculated to be about 95%. End-pumped by a diode laser at 970 nm in a hemispherical cavity, a 0.75 W quasi-CW laser at 1.5-1.6 μm with a slope efficiency of 7% and an absorbed pump threshold of 3.8 W was achieved in a 0.5-mm-thick Z-cut crystal glued on a 5-mm-thick pure YAG crystal with UV-curable adhesive.

  2. Research progress on laser crystals in China

    NASA Astrophysics Data System (ADS)

    Yingxia, Z.

    1985-01-01

    Current Chinese research on laser crystals is now quite extensive and involves more than 30 research teams with nearly 1,000 technicians and workers actively engaged in the study of more than 20 types of laser cyrstals. Neodymium-doped yttrium aluminum garnet (Nd:YAG) and ruby (Cr:Al2O3) lasers have been manufactured and are widely employed. There are several new and promising crystals now under study which will find applications, and both basic and exploratory research have given rise to new developments.

  3. Neodymium: YAG laser damage threshold. A comparison of injection-molded and lathe-cut polymethylmethacrylate intraocular lenses.

    PubMed

    Wilson, S E; Brubaker, R F

    1987-01-01

    The possibility that injection-molded intraocular lenses (IOLs) with imperfections called iridescent clefts could have a decreased threshold to neodymium: YAG (Nd:YAG) laser-induced damage was investigated. Thresholds for Nd:YAG laser-induced damage were determined for injection-molded and lathe-cut polymethylmethacrylate lenses. When aimed at a membrane in contact with a posterior convex surface, the average thresholds were 0.96 +/- 0.18 mJ (Standard deviation [SD]) and 1.80 +/- 0.55 mJ, respectively. The difference was significant at P = 0.001. When injection-molding polymethylmethacrylate was used to make lathe-cut IOLs, very few iridescent clefts were present, and the threshold to Nd:YAG laser-induced damage was 0.94 +/- 0.25 mJ. Iridescent clefts are therefore produced during the injection-molding process but they do not lower the threshold to Nd:YAG laser-induced damage. Rather, the reduced threshold in injection-molded lenses is most probably a result of the polymethylmethacrylate used in their manufacture. Clinically, iridescent clefts in a lens suggest that it has been manufactured by an injection-molding process and that Nd:YAG laser posterior capsulotomy must be performed at the lowest possible energy level to avoid damage.

  4. Growth and characterization of hexamethylenetetramine crystals grown from solution

    NASA Astrophysics Data System (ADS)

    Babu, B.; Chandrasekaran, J.; Balaprabhakaran, S.

    2014-06-01

    Organic nonlinear optical single crystals of hexamethylenetetramine (HMT; 10 × 10 × 5 mm3) were prepared by crystallization from methanol solution. The grown crystals were subjected to various characterization techniques such as single crystal XRD, powder XRD, UV-Vis and electrical studies. Single crystal XRD analysis confirmed the crystalline structure of the grown crystals. Their crystalline nature was also confirmed by powder XRD technique. The optical transmittance property was identified from UV-Vis spectrum. Dielectric measurements were performed as a function of frequency at different temperatures. DC conductivity and photoconductivity studies were also carried out for the crystal. The powder second harmonic generation efficiency (SHG) of the crystal was measured using Nd:YAG laser and the efficiency was found to be two times greater than that of potassium dihydrogen phosphate (KDP).

  5. Pulsed Tm:YAG laser ablation of knee joint tissues

    NASA Astrophysics Data System (ADS)

    Shi, Wei-Qiang; Vari, Sandor G.; Duffy, J. T.; Miller, J. M.; Weiss, Andrew B.; Fishbein, Michael C.; Grundfest, Warren S.

    1992-06-01

    We investigated the effect of a free-running 2.01 micron pulsed Tm:YAG laser on bovine knee joint tissues. Ablation rates of fresh fibrocartilage, hyaline cartilage, and bone were measured in saline as a function of laser fluence (160 - 640 J/cm2) and fiber core size (400 and 600 microns). All tissues could be effectively ablated and the ablation rate increased linearly with the increasing fluence. Use of fibers of different core sizes, while maintaining constant energy fluence, did not result in significant difference in ablation rate. Histology analyses of the ablated tissue samples reveal average Tm:YAG radiation induced thermal damage (denatunalization) zones ranging between 130 and 540 microns, depending on the laser parameters and the tissue type.

  6. FT-Raman spectroscopic characterization of enamel surfaces irradiated with Nd:YAG and Er:YAG lasers

    PubMed Central

    Shahabi, Sima; Fekrazad, Reza; Johari, Maryam; Chiniforoush, Nasim; Rezaei, Yashar

    2016-01-01

    Background. Despite recent advances in dental caries prevention, caries is common and remains a serious health problem. Laser irradiation is one of the most common methods in preventive measures in recent years. Raman spectroscopy technique is utilized to study the microcrystalline structure of dental enamel. In this study, FT-Raman spectroscopy was used to evaluate chemical changes in enamel structure irradiated with Nd:YAG and Er:YAG lasers. Methods. We used 15 freshly-extracted, non-carious, human molars that were treated as follows: No treatment was carried out in group A (control group); Group B was irradiated with Er:YAG laser for 10 seconds under air and water spray; and Group C was irradiated with Nd:YAG laser for 10 seconds under air and water spray. After treatment, the samples were analyzed by FT-Raman spectroscopy. Results. The carbonate content evaluation with regard to the integrated area under the curve (1065/960 cm–1) exhibited a significant reduction in its ratio in groups B and C. The organic content (2935/960 cm-1) area exhibited a significant decrease after laser irradiation in group B and C. Conclusion. The results showed that the mineral and organic matrices of enamel structure were affected by laser irradiation; therefore, it might be a suitable method for caries prevention. PMID:28096945

  7. Photoablation of the cornea with a Q-switched Er:YAG laser

    NASA Astrophysics Data System (ADS)

    Lubatschowski, Holger; Hetzel, U.; Kermani, Omid; Ziolek, Carsten; Drommer, Wolfgang; Ertmer, Wolfgang

    1997-12-01

    In this study the ablation characteristics and the wound healing process of rabbit cornea irradiated with a Q- switched Er:YAG laser was evaluated. The laser, emitting at 2.94 micrometers wavelength, has a pulse width of 100 ns. The spot size on the corneal surface was 1 mm in diameter at a fluence of 750 mJ/cm2. The laser beam was applied by a `flying spot' mode, performing refractive ablations of -7 to -8 dpt. As a biological model, the corneas of 9 rabbits were irradiated. The post-treatment follow-up was as long as 39 days. The treated corneas were investigated by light and electron microscopy. The wound healing on rabbit cornea of the Q-switched Er:YAG laser radiation in corneal tissue processing resembles to what is known from ArF- excimer laser application. To shorten the pulse width by means of Q-switching is one major key to the successful application of the Er:YAG laser for PRK.

  8. SPF-RR sequential photothermal fractional resurfacing and remodeling with the variable pulse Er:YAG laser and scanner-assisted Nd:YAG laser.

    PubMed

    Marini, Leonardo

    2009-12-01

    Many different lasers, polychromatic high-intensity light sources (PCLs), and RF devices have claimed clinical efficacy in rejuvenating the skin. In this study, the sequential combination of two different laser wavelengths was evaluated to produce reliably significant clinical improvements optimizing treatment parameters. The left volar aspects of the forearms of four volunteers were treated with nine different parameter settings using a variable pulsewidth fractional Er:YAG 2940-nm laser with and without air cooling. The pain perception level was recorded on a 0-10 point scale (0=No pain; 10=Most severe pain). Three evaluations were made: during treatment, immediately after treatment, and 5 minutes after treatment. The same investigation was made on the right volar aspects of the same four volunteers using a short-pulse, random pattern, 3-mm spot, scanner-assisted Nd-YAG 1064-nm laser at 0.3 ms pulsewidth at seven different parameter settings. Clinical evaluations were made concerning erythema and edema 3 days after treatment, as well as pre-operative and 60 days postoperative skin texture plus color uniformity. Considering that the majority of cosmetic patients are willing to accept a relatively short and uneventful downtime (2-4 days according to a study we are presently conducting) and do prefer to limit their intra- and postoperative pain to a minimum, the best combination of clinical improvement matching these two important parameters were selected for our study. A treatment strategy combining two sequential passes of long-pulse Nd:YAG laser (Nd:YAG-LP) at 0.3 and 35 ms followed by two passes of long-pulse fractional Er:YAG laser (Er:YAG-FT) at 600 micros was designed to treat the facial regions of 10 volunteers affected by a combination of intrinsic (chrono-) and extrinsic (mostly photo-) aging. The pain perception level was recorded on a 0-10 scale (0=No pain; 10=Most severe pain). Three evaluations were made: during, immediately after, and 5 minutes after

  9. A compound crystal with film scintillator for electron detection

    NASA Astrophysics Data System (ADS)

    McKinney, George; McDonnald, Warren; Tzolov, Marian

    2015-03-01

    Yttrium Aluminum Garnets (YAG) and Yttrium Aluminum Perovskite (YAP) are widely used as electron detectors. This application requires a top conducting layer which hinders their application at low electron energies. We have developed a layer of zinc tungstate which delivers conductivity large enough to prevent charging while still being an efficient scintillator. For better coupling between the two systems we have studied their optical properties. Ce doping is an essential element in YAP and YAG in order for them to be efficient scintillators. We have studied the Ce content and we show that higher Ce content leads to reabsorption in the YAP scintillators. These details were revealed by using photoluminescence emission and excitation spectroscopy. The absorption spectrum for the YAG scintillators coincides with the excitation for the main emission lines. The optical studies of the zinc tungstate films and a single crystal have shown that the films are more efficient light emitters. We have integrated the zinc tungstate films with YAG scintillators and we will report on the performance of this compound scintillator. It is expected that it will perform well at low and high electron energies, which makes it a very cost effective platform for electron detectors.

  10. Analysis of erythema after Er:YAG laser skin resurfacing.

    PubMed

    Ko, Na Young; Ahn, Hyo-Hyun; Kim, Soo-Nam; Kye, Young-Chul

    2007-11-01

    Postoperative erythema can be expected to occur in every patient after laser resurfacing, and pigmentary disturbances may be related to the intensity and the duration of erythema. This study was undertaken to assess the clinical features of erythema, the factors that influence its duration, and the relation between the duration of erythema and the incidence of hyperpigmentation and hypopigmentation in skin of Asian persons after Er:YAG laser resurfacing. A total of 218 patients (skin phototypes III to V) were recruited and treated with a short-pulsed Er:YAG laser, a variable-pulsed Er:YAG laser, or a dual-mode Er:YAG laser for skin resurfacing. Clinical assessments were performed retrospectively using medical charts and serial photographs. Postoperative erythema was observed in all patients after Er:YAG laser resurfacing with a mean duration of 4.72 months. In 98.2% of patients, erythema faded completely within 12 months. Postinflammatory hyperpigmentation was observed in 38.1% of patients after Er:YAG laser resurfacing. Skin phototype, level of ablation, and depth of thermal damage caused by a long-pulsed laser appear to be important factors that affect the duration of erythema. Moreover, prolonged erythema was related to the risk of postinflammatory hyperpigmentation.

  11. Investigation of crystallization kinetics of sodium bicarbonate in a continuous stirred tank crystallizer

    NASA Astrophysics Data System (ADS)

    Zhu, Yi; Haut, Benoît; Halloin, Veronique; Delplancke-Ogletree, Marie-Paule

    2005-08-01

    In our previous work [J. Crystal Growth 263 (2004) 459], a supersaturation determination method using a high-precision densimeter was designed and developed for monitoring sodium bicarbonate supersaturation in the sodium carbonate-bicarbonate system, a two-component solution in equilibrium. In the present paper, we apply this method to the study of sodium bicarbonate continuous crystallization. It gives us access to the sodium bicarbonate supersaturation evolution. The sodium bicarbonate supersaturation evolution and their crystallization kinetics obtained in a continuous stirred tank crystallizer are investigated under different operational conditions, such as residence time, initial supersaturation and seeding. The induction time determined by density measurements is discussed. Mathematical modeling is used to interpret the supersaturation evolution. It is shown that measuring the density gives satisfying performances for studying the crystallization of a two-component solution in equilibrium, such as the sodium carbonate-bicarbonate system.

  12. The effect of Fe 3+ doping in Potassium Hydrogen Phthalate single crystals on structural and optical properties

    NASA Astrophysics Data System (ADS)

    Kumar, R. Ashok; Sivakumar, N.; Vizhi, R. Ezhil; Babu, D. Rajan

    2011-02-01

    This work investigates the influence of iron doping on Potassium Hydrogen Phthalate (KHP) single crystals by the slow evaporation solution growth technique. Factors such as evaporation rate, solution pH, solute concentration, super saturation limit, etc. are very important in order to have optically transparent single crystals. As part of the work, the effects of metallic salt FeCl 3 in different concentrations were analyzed with pure KHP. Powder X-ray diffraction suggests that the grown crystals are crystallized in the orthorhombic structure. The functional groups and the effect of moisture on the doped crystals can be analyzed with the help of a FTIR spectrum. The pure and doped KHP single crystal shows good transparency in the entire visible region, which is suitable for optical device applications. The refractive indices along b axis of pure and doped KHP single crystals were analyzed by the prism coupling technique. The emission of green light with the use of a Nd:YAG laser ( λ=1064 nm) confirmed the second harmonic generation properties of the grown crystals.

  13. Low-threshold, nanosecond, high-repetition-rate vortex pulses with controllable helicity generated in Cr,Nd:YAG self-Q-switched microchip laser

    NASA Astrophysics Data System (ADS)

    He, Hong-Sen; Chen, Zhen; Li, Hong-Bin; Dong, Jun

    2018-05-01

    A high repetition rate, nanosecond, pulsed optical vortex beam has been generated in a Cr,Nd:YAG self-Q-switched microchip laser pumped by the annular-beam formed with a hollow focus lens. The lasing threshold for vortex pulses is 0.9 W. A pulse width of 6.5 ns and a repetition rate of over 330 kHz have been achieved. The average output power of 1 W and the slope efficiency of 46.6% have been obtained. The helicity of the optical vortices has been controlled by adjusting the tilted angle between Cr,Nd:YAG crystal and output coupler. The work provides a new method for developing pulsed optical vortices for potential applications on quantum communication and optical trapping.

  14. Continuous-wave operation of a room-temperature, diode-laser-pumped, 946-nm Nd:YAG laser

    NASA Technical Reports Server (NTRS)

    Fan, T. Y.; Byer, Robert L.

    1987-01-01

    Single-stripe diode-laser-pumped operation of a continuous-wave 946-nm Nd:YAG laser with less than 10-mW threshold has been demonstrated. A slope efficiency of 16 percent near threshold was shown with a projected slope efficiency well above a threshold of 34 percent based on results under Rhodamine 6G dye-laser pumping. Nonlinear crystals for second-harmonic generation of this source were evaluated. KNbO3 and periodically poled LiNbO3 appear to be the most promising.

  15. Temperature rises during application of Er:YAG laser under different primary dentin thicknesses.

    PubMed

    Hubbezoglu, Ihsan; Unal, Murat; Zan, Recai; Hurmuzlu, Feridun

    2013-05-01

    The present study investigated the effects of the Er:YAG laser's different pulse repetition rates on temperature rise under various primary dentin thicknesses. The Er:YAG laser can be used for restorative approaches in clinics and is used to treat dental caries. There are some reports that explain the temperature rise effect of the Er:YAG laser. Recently, the Er:YAG laser has been found to play an important role in temperature rises during the application on dentin. Caries-free primary mandibular molars were prepared to obtain dentin discs with 0.5, 1, 1.5, and 2 mm thicknesses (n=10). These discs were placed between the Teflon mold cylinders of a temperature test apparatus. We preferred three pulse repetition rates of 10, 15, and 20 Hz with an energy density of 12.7 J/cm2 and a 230 μs pulse duration. All dentin discs were irradiated for 30 sec by the Er:YAG laser. Temperature rises were recorded using an L-type thermocouple and universal data loggers/scanners (E-680, Elimko Co., Turkey). Data were analyzed by two-way ANOVA and Tukey tests. Whereas the lowest temperature rise (0.44±0.09 °C) was measured from a 10 Hz pulse repetition rate at a dentin thickness of 2 mm, the highest temperature rise (3.86±0.43 °C) was measured from a 20 Hz pulse repetition rate at a 0.5 mm dentin thickness. Temperature rise did not reach critical value for pulpal injury in any primary dentin thicknesses irradiated by a high repetition rate of the Er:YAG laser.

  16. Effect of doping of KDP crystal with amino acid L-arginine on the strength properties and character of laser damage

    NASA Astrophysics Data System (ADS)

    Dolzhenkova, E. F.; Kostenyukova, E. I.; Bezkrovnaya, O. N.; Pritula, I. M.

    2017-11-01

    Studied were the strength characteristics of KDP crystals doped with L-arginine under a concentrated load and irradiation of the first harmonic YAG:Nd3+ laser. The crystals were obtained by means of the temperature reduction method on a point seed, the content of L-arginine in the aqueous solution being 0.3, 0.4, 1.0 and 1.4 wt%. The character of the dependence of KDP microhardness versus the concentration of amino acid in the crystal was investigated. The regularities of brittle damage of the doped KDP crystal at mechanical testing and laser irradiation were shown to be similar. As confirmed in the study, the planes of easy crack extension in the crystal are {2 2 1}, (1 0 0), and (0 0 1) planes, the cracks mainly propagate parallel to {2 2 1} planes. The mechanical and laser strength values of doped KDP crystals were evaluated.

  17. Solid-state synthesis of YAG powders through microwave coupling of oxide/carbon particulate mixtures

    DOE PAGES

    Wildfire, Christina; Sabolsky, Edward M.; Spencer, Michael J.; ...

    2017-06-14

    The rapid synthesis of yttrium aluminum garnet (Y 3Al 15O 12, YAG) powder was investigated through the use of microwave irradiation of the oxide precursor system. For this investigation, an external hybrid heating source was not used. Instead, the rapid heating of the precursor materials (yttria and alumina powders, which are typically transparent to 2.45 GHz microwaves) was initiated by mixing an intrinsic absorbing material (carbon) into the original oxide precursors. The effect of the carbon characteristics, such as carbon source, concentration, particle size, and agglomerate microstructure were evaluated on the efficiency of coupling and resultant oxide reaction. The microwavemore » power was varied to optimize the YAG conversion and eliminate intermediate phase formation. Interactions between the conductive carbon particles and the dielectric oxides within the microwave exposure produced local arching and micro-plasma formation within the powder bed, resulting in the rapid formation of the refractory YAG composition. This optimal conduction led to temperatures of 1000°C that could be achieved in less than 5 min resulting in the formation of > 90 vol% YAG. The understanding of a conductor/dielectric particulate system here, provided insight into possible application of similar systems where microwave irradiation could be used for enhanced solid-state formation, local melting events, and gas phase reactions with a composite powder media.« less

  18. Heat treatment of transparent Yb:YAG and YAG ceramics and its influence on laser performance

    NASA Astrophysics Data System (ADS)

    Fujioka, Kana; Mochida, Tetsuo; Fujimoto, Yasushi; Tokita, Shigeki; Kawanaka, Junji; Maruyama, Momoko; Sugiyama, Akira; Miyanaga, Noriaki

    2018-05-01

    Composite transparent ceramic materials are promising for improving the performance of high-average-power lasers. A combination of room-temperature bonding via surface treatment by a fast atom beam and diffusion bonding via heating, which effectively controls the ion diffusion distance near the interface, makes the laser materials suitable for a variety of oscillator/amplifier. During the heat treatment of yttrium aluminum garnet (YAG) ceramics, the Si ions in the solid solution of the sintering aid incorporated within the grains were seen to segregate at the grain boundary, resulting in an increase of scattering sites. The number density and size of the scattering sites strongly depended on the post-heating temperature rather than the heating time. Specifically, heating at 1300 °C did not affect the transmittance of the YAG ceramic, whereas both the size and number of scattering sites substantially increased with a heat treatment at 1400 °C. The laser oscillation experiment using cryogenically-cooled Yb:YAG ceramics exhibited heating temperature dependence of the slope efficiency owing to the increasing scattering loss.

  19. CO2 and Er:YAG laser interaction with grass tissues

    NASA Astrophysics Data System (ADS)

    Kim, Jaehun; Ki, Hyungson

    2013-01-01

    Plant leaves are multi-component optical materials consisting of water, pigments, and dry matter, among which water is the predominant constituent. In this article, we investigate laser interaction with grass using CO2 and Er:YAG lasers theoretically and experimentally, especially targeting water in grass tissues. We have first studied the optical properties of light absorbing constituents of grass theoretically, and then have identified interaction regimes and constructed interaction maps through a systematic experiment. Using the interaction maps, we have studied how interaction regimes change as process parameters are varied. This study reveals some interesting findings concerning carbonization and ablation mechanisms, the effect of laser beam diameter, and the ablation efficiency and quality of CO2 and Er:YAG lasers.

  20. Efficient, frequency-stable laser-diode-pumped Nd:YAG laser

    NASA Technical Reports Server (NTRS)

    Zhou, B.; Kane, T. J.; Dixon, G. J.; Byer, R. L.

    1985-01-01

    One of the main goals of the study was to demonstrate a low-power efficient Nd:YAG laser oscillator for applications in remote coherent Doppler anemometry. An electrical-to-optical slope efficiency of 6.5 percent has been achieved by using commercially available CW laser diodes of up to 100 mW to pump monolithic Nd:YAG rod lasers. The observed Nd:YAG oscillation threshold is at 2.3 mW of laser-diode output power, i.e., a small fraction of the rated output power. The highest Nd:YAG CW output power reached is 4.4 mW at an overall electrical-to-optical efficiency of 1.5 percent. The frequency jitter is less than 10 kHz in 0.3 s.

  1. Scanning electron microscopic study of the effects of Er:YAG laser on root cementum.

    PubMed

    Fujii, T; Baehni, P C; Kawai, O; Kawakami, T; Matsuda, K; Kowashi, Y

    1998-11-01

    Use of Er:YAG laser has been proposed for the removal of microbial deposits and calculus present on teeth affected by periodontal disease. However, the influence of Er:YAG laser irradiation on root surfaces has not yet been fully investigated. The aim of the present study was to evaluate the effects of Er:YAG laser irradiation on root cementum by scanning electron microscopy (SEM). Specimens were obtained from extracted human periodontally-diseased teeth using a water-cooled high-speed bur. An Er:YAG laser beam was then applied at various powers ranging from 25 to 100 mJ/ pulse/sec. The laser irradiation was performed under water irrigation, with the tip held perpendicular to the root surface in the contact mode. Following laser exposure, specimens were fixed, dehydrated, and dried at critical-point in liquid CO2. After mounting on SEM plates and sputter-coating with gold, the cementum surface was examined by SEM. Observations of the root surface showed a relatively flat surface in control specimens. In Er:YAG exposed specimens, the laser beam created a circular, notched-edge, crater-like defect on the root. The bottom of the lesion showed an irregular and sharp-pointed surface. Subsequently, the specimens were fractured with a sharp scalpel perpendicularly to the surface. SEM observations of these specimens showed a 15 microm layer of damaged tissue within the laser-irradiated cementum. The tissue presented an amorphous appearance and the Sharpey's and matrix fiber bundles were not clearly distinguishable. These observations indicate that cementum tissue could be damaged by Er:YAG laser irradiation.

  2. Effects of Er:YAG laser irradiation on human dentin: polarizing microscopic, light microscopic and microradiographic observations, and FT-IR analysis.

    PubMed

    Ishizaka, Yaeko; Eguro, Toru; Maeda, Toru; Tanaka, Hisayoshi

    2002-01-01

    The effects of Er:YAG laser irradiation on dentin have not been sufficiently investigated. The purpose of this study was to investigate the effects of Er:YAG laser irradiation on dentin. After cavities were prepared using Er:YAG laser irradiation or rotary cutting instruments, histological observations of cavity-floor dentin utilizing polarizing microscopy, microradiography and light microscopy, and analysis of composition of cavity-floor dentin using Fourier-transformed (FT-IR) spectrometry were conducted. In the laser-treated side, a deeply stained basophilic layer was observed. The number of odontoblastic processes present was obviously less in the laser-treated side than in the bur-treated side. FT-IR analysis revealed that compared to the bur-treated side, a broad background peak at around 1,600 cm(-1) was present. Er:YAG laser irradiation might have denatured the organic materials of dentin. Copyright 2002 Wiley-Liss, Inc.

  3. Development and Fabrication of a Space Hardened Nd(3+) YAG Laser Transmitter System for Orbital Range and Altitude Control

    DTIC Science & Technology

    1975-05-06

    YAG system, to. be able to operate’in a ground launched satellite. ) Study was conducted to identify and eliminate all sources of laser degradation...further studies and the design of the space-hardened Laser Transmitter.I The study included such topics as general interferometer stability, internally...generated perturbances, external perturbations and their effects on the I’ laser stability. Further study covered the Laser Crystal parameters such as

  4. Effect of Li and NH4 doping on the crystal perfection, second harmonic generation efficiency and laser damage threshold of potassium pentaborate crystals

    NASA Astrophysics Data System (ADS)

    Vigneshwaran, A. N.; Kalainathan, S.; Raja, C. Ramachandra

    2018-03-01

    Potassium pentaborate (KB5) is an excellent nonlinear optical material especially in the UV region. In this work, Li and NH4 doped KB5 crystals were grown using slow evaporation solution growth method. The incorporation of dopant has been confirmed and analysed by Energy dispersive X-ray analysis (EDAX), Inductively coupled plasma (ICP) analysis and Raman spectroscopy. The crystalline perfection of pure and doped KB5 crystals was studied by High resolution X-ray diffraction (HRXRD) analysis. Structural grain boundaries were observed in doped crystals. Second harmonic generation was confirmed for pure and doped crystals and output values revealed the enhancement of SHG efficiency in doped crystals. Resistance against laser damage was carried out using 1064 nm Nd-YAG laser of pulse width 10 ns. The laser damage threshold value is increased in Li doped crystal and decreased in NH4 doped crystal when compared to pure KB5 crystal.

  5. Microstructure development and photoluminescence of annealed nanosized Ce:YAG/Al2O3 and Ce:YAG/Cr:Al2O3 powder composites

    NASA Astrophysics Data System (ADS)

    Peter, Samuel; Kuyanov, Paul; Isik Goktas, Nebile; LaPierre, Ray; Kitai, Adrian

    2018-03-01

    In an effort to control aggregation and sintering of phosphor nanoparticles at elevated annealing temperatures, glycothermally synthesized cerium-doped yttrium aluminum garnet (Ce:YAG) nanoparticles were annealed in a matrix of aluminum oxide between 1000 °C and 1200 °C. Scanning electron microscopy images showed that glycothermal synthesis yields ∼100 nm particles, and that the alumina matrix was able to control grain growth of Ce:YAG at annealing temperatures up to 1200 °C. Analysis by x-ray diffraction and Fourier transform infrared spectroscopy showed an increase in the degree of crystallinity at increasing temperatures as well as the evolution of alumina phases. Photoluminescence of the composite product showed the expected broad Ce:YAG spectrum, with characteristic chromium R lines present due to the formation of corundum at 1200 °C with trace chromium content. The same procedure was performed to synthesize a Ce:YAG/Cr:Al2O3 nanocomposite, yielding photoluminescence of both the expected Ce:YAG and Cr:Al2O3 peaks as well as clear evidence of energy transfer between Ce and Cr centers in YAG. The luminescence of these composites was used to determine their CIE colour co-ordinates. It was found that the colour profile of the resulting emission may be tuned by adjusting the Cr content and annealing conditions of the composite materials.

  6. Composite, all-ceramics, high-peak power Nd:YAG/Cr(4+):YAG monolithic micro-laser with multiple-beam output for engine ignition.

    PubMed

    Pavel, Nicolaie; Tsunekane, Masaki; Taira, Takunori

    2011-05-09

    A passively Q-switched Nd:YAG/Cr(4+):YAG micro-laser with three-beam output was realized. A single active laser source made of a composite, all-ceramics Nd:YAG/Cr(4+):YAG monolithic cavity was pumped by three independent lines. At 5 Hz repetition rate, each line delivered laser pulses with ~2.4 mJ energy and 2.8-MW peak power. The M(2) factor of a laser beam was 3.7, and stable air breakdowns were realized. The increase of pump repetition rate up to 100 Hz improved the laser pulse energy by 6% and required ~6% increase of the pump pulse energy. Pulse timing of the laser-array beams can by adjusted by less than 5% tuning of an individual line pump energy, and therefore simultaneous multi-point ignition is possible. This kind of laser can be used for multi-point ignition of an automobile engine. © 2011 Optical Society of America

  7. Structural and optical behavior due to thermal effects in end-pumped Yb:YAG disk lasers.

    PubMed

    Sazegari, Vahid; Milani, Mohammad Reza Jafari; Jafari, Ahmad Khayat

    2010-12-20

    We employ a Monte Carlo ray-tracing code along with the ANSYS package to predict the optical and structural behavior in end-pumped CW Yb:YAG disk lasers. The presence of inhomogeneous temperature, stress, and strain distributions is responsible for many deleterious effects for laser action through disk fracture, strain-induced birefringence, and thermal lensing. The thermal lensing, in turn, results in the optical phase distortion in solid-state lasers. Furthermore, the dependence of optical phase distortion on variables such as the heat transfer coefficient, the cooling fluid temperature, and crystal thickness is discussed.

  8. Er:YAG and Nd:YAG laser in treatment of patients with contraindications of conventional dental and maxillofacial surgery

    NASA Astrophysics Data System (ADS)

    Smucler, Roman; Mazanek, Jiri

    2000-03-01

    In clinical praxis we must treat patients with some relative or absolute contraindications every day. Need of hospitalization, antibiotics, hemostyptics and complex examinations makes dentoalveolar and maxillofacial surgery in those cases quite expensive. Combination of Nd:YAG and Er:YAG laser gives us new possibilities. We can help some untreatable patients or transfer care from hospital to dental office. We have been trying to solve contraindications for laser therapy five years. In the center of our work are disorders of blood coagulation, immunity and metabolism. Nd:YAG laser is very useful in coagulation and vaporization of dental gum hypertrophies, benign and malign tumors in case of chronic anticoagulation therapy and immunosupress / in combination for example- after heart transplantation /. Special chapter is the care of patients with disseminated tumors. Er:YAG laser large solve big lesions because of minimal invasivity of course but for small benign tumors are recidives is ideal. Better and quicker healing make new standard of patients' cooperation. Generally fashionable and more comfortable laser treatment minimize need of general anesthesia. After five years we use complex laser therapy in our routine. Aim of our new work is to find ideal combination of cutting lasers to minimize classical complications of laser surgery / carbonization, long and secondary healing /.

  9. Development of YAG:Dy Thermographic Phosphor Coatings for Turbine Engine Applications

    NASA Technical Reports Server (NTRS)

    Eldridge, J. I.; Jenkins, T. P.; Allison, S. W.; Wolfe, D. E.; Jordan, E. H.

    2012-01-01

    The selection and development of thermographic phosphor coatings were pursued to meet the objective of demonstrating luminescence-decay-based temperature measurements up to 1300C on the surface of a vane in an operating demonstrator turbine engine. To meet this objective, YAG:Dy was selected based on the desirable luminescence performance observed for YAG:Dy powder: (1) excellent temperature sensitivity and intensity at operating turbine engine temperatures, (2) an emission peak at the relatively short wavelength of 456 nm, where the interference from background blackbody radiation is fairly low, and (3) its nearly single exponential decay which makes for a simple, reliable temperature calibration. However, implementation of YAG:Dy for surface temperature measurements required application of YAG:Dy as a coating onto the surface of a superalloy component with a preexisting yttria-stabilized zirconia (YSZ) thermal barrier coating (TBC). An inherent dilemma in producing a YAG:Dy coating is that coating processing is constrained to be performed at temperatures below (less than 1200C) what is considered safe for the superalloy component, much lower than temperatures used to produce the high quality crystalline powder. Therefore, YAG:Dy coatings tend to exhibit lower luminescence performance compared to well prepared YAG:Dy powder, and the luminescence performance of the coating will depend on the method of coating deposition. In this presentation, the luminescence performance of YAG:Dy coatings prepared by the different methods of (1) application of a binder-based YAG:Dy-containing paint, (2) solution precursor plasma spray (SPPS), and (3) electron-beam physical vapor deposition (EB-PVD) and the effect of post-deposition heat treatments will be discussed.

  10. Treatment of pigmented keratosis pilaris in Asian patients with a novel Q-switched Nd:YAG laser.

    PubMed

    Kim, Sangeun

    2011-06-01

    Treatment for most cases of keratosis pilaris requires simple reassurance and general skin care recommendations. Many Asian patients find lesions due to pigmented keratosis pilaris to be cosmetically unappealing. Treatment of post-inflammatory hyperpigmentation using a 1064-nm Q-switched Nd:YAG laser with low fluence is reported. To investigate the efficacy of a novel Q-switched Nd:YAG laser for the treatment of pigmented keratosis pilaris in Asian patients. Ten patients with pigmented keratosis pilaris underwent five weekly treatments using a Q-switched Nd:YAG laser (RevLite(®); HOYA ConBio(®), Freemont, CA, USA) at 1064 nm with a 6-mm spot size and a fluence of 5.9 J/cm(2). Photographic documentation was obtained at baseline and 2 months after the final treatment. Clinical improvement was achieved in all 10 patients with minimal adverse effects. For the treatment of keratosis pilaris, the use of a Q-switched Nd:YAG laser can be helpful for improving cosmetic appearance as it can improve pigmentation.

  11. A novel dual‐wavelength, Nd:YAG, picosecond‐domain laser safely and effectively removes multicolor tattoos

    PubMed Central

    Schomacker, Kevin T.; Basilavecchio, Lisa D.; Plugis, Jessica M.; Bhawalkar, Jayant D.

    2015-01-01

    Background and Objectives Although nanosecond‐domain lasers have been the mainstay of laser tattoo removal for decades, recent disruptive innovations in laser design have introduced a new class of commercial Q‐switched lasers that generate picosecond‐domain pulses. Study A picosecond‐domain, Nd:YAG laser with a KTP frequency‐doubling crystal was used to treat 31 decorative tattoos in 21 subjects. Safety and effectiveness were determined by blinded evaluation of digital images in this prospective clinical study. Results The average clearance overall as evaluated by blinded observers evaluating randomized digital photographs was 79 ± 0.9% (mean ± sem) after an average of 6.5 treatments. Of the 31 tattoos completing treatment, 6 had evidence of mild hyper‐ or hypo‐pigmentation by evaluation of photographs. Conclusion The 350 picosecond, 532 nm, and 450 picosecond 1,064 nm Nd:YAG laser is safe and effective for removing decorative tattoos. Lasers Surg. Med. 47:542–548, 2015. © 2015 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. PMID:26175187

  12. Growth and characterization of organic material 4-dimethylaminobenzaldehyde single crystal.

    PubMed

    Jebin, R P; Suthan, T; Rajesh, N P; Vinitha, G; Madhusoodhanan, U

    2015-01-25

    The organic material 4-dimethylaminobenzaldehyde single crystals were grown by slow evaporation technique. The grown crystal was confirmed by the single crystal and powder X-ray diffraction analyses. The functional groups of the crystal have been identified from the Fourier Transform Infrared (FTIR) and FT-Raman studies. The optical property of the grown crystal was analyzed by UV-Vis-NIR and photoluminescence (PL) spectral measurements. The thermal behavior of the grown crystal was analyzed by thermogravimetric (TG) and differential thermal analyses (DTA). Dielectric measurements were carried out with different frequencies by using parallel plate capacitor method. The third order nonlinear optical properties of 4-dimethylaminobenzaldehyde was measured by the Z-scan technique using 532 nm diode pumped continuous wave (CW) Nd:YAG laser. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Growth of crystals for synchrotron radiation Mössbauer investigation

    NASA Astrophysics Data System (ADS)

    Kotrbova, M.; Hejduk, J.; Malnev, V. V.; Seleznev, V. N.; Yagupov, S. V.; Andronova, N. V.; Chechin, A. I.; Mikhailov, A. Yu.

    1991-10-01

    Iron borate crystals (FeBO 3) were flux grown at the Physical Institute (Prague) and at Simferopol State University. During the crystal growth procedure the temperature regime was held constant to 0.1°C accuracy. Crystals were investigated with the help of a double crystal X-ray diffractometer DRON-2 (SiO 2(30 overline33)FeBO 3(444), MoK α 1 radiation). The rocking curve measurements were carried out in a constant magnetic field of 1kG. Most of the crystal surface has a rocking curve 10″-15″ wide. Some parts of some crystals with the area 1 × 1 mm 2 have rocking curves of 3″-4″ width and can be considered ideal.

  14. Characteristics of AFB interfaces of dissimilar crystal composites as components for solid state lasers

    NASA Astrophysics Data System (ADS)

    Lee, H. C.; Meissner, O. R.; Meissner, H. E.

    2005-06-01

    Adhesive-free bonded (AFB®) composite crystals have proven to be useful components in diode-pumped solid-state lasers (DPSSL). The combination of a lasing medium of higher index of refraction with laser-inactive cladding layers of lower index results in light- or wave-guided slab architectures. The cladding layers also serve to provide mechanical support, thermal uniformity and a heat sink during laser operation. Therefore, the optical and mechanical properties of these components are of interest for the design of DPSSL, especially at high laser fluencies and output power. We report on process parameters and material attributes that result in stress-free AFB® composites that are resistant to thermally induced failure. Formation of stress-free and durable bonds between two dissimilar materials requires heat-treatment of composites to a temperature high enough to ensure durable bonds and low enough to prevent forming of permanent chemical bonds. The onset temperature for forming permanent bonds at the interface sets the upper limit for heat treatment. This limiting temperature is dependent on the chemical composition, crystallographic orientation, and surface characteristics. We have determined the upper temperature limits for forming stress-free bonds between YAG and sapphire, YAG and GGG, YAG and spinel, spinel and sapphire, spinel and GGG, and sapphire and GGG composites. We also deduce the relative magnitude of thermal expansion coefficients amongst the respective single crystals as αGGG > αsapp_c > αspinel > αYAG > αsapp_a from interferometric analysis.

  15. Trivalent cerium coped crystals as tunable laser systems: two bad apples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamilton, D.S.

    1985-01-01

    The 5d-4f transitions of trivalent doped crystals have broad emission bands with large oscillator strengths and near unity quantum efficiency. These characteristics make cerium systems strong candidates for tunable solid state lasers. However, two such cerium crystals will probably never lase. The first is Ce/sup 3 +/:YAG where a strong excited state absorption quenches the lasing transition. Our recent measurements have indicated that the excited state absorption terminates in the YAG conduction band with a peak cross section of 1.0 x 10/sup -17/ cm/sup 2/ at 700 nm. Some of the general features of impurity ion to band spectra aremore » discussed. The second system is Ce/sup 3 +/:CaF/sub 2/ where a uv pump induced photochromic center is produced following excitation of the cerium ions. The initial measurements of cerium related transient absorptions in Ce/sup 3 +/:YLF are also presented.« less

  16. 21 CFR 886.4392 - Nd:YAG laser for posterior capsulotomy and peripheral iridotomy.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nd:YAG laser for posterior capsulotomy and...:YAG laser for posterior capsulotomy and peripheral iridotomy. (a) Identification. The Nd:YAG laser for... laser intended for disruption of the posterior capsule or the iris via optical breakdown. The Nd:YAG...

  17. 21 CFR 886.4392 - Nd:YAG laser for posterior capsulotomy and peripheral iridotomy.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nd:YAG laser for posterior capsulotomy and...:YAG laser for posterior capsulotomy and peripheral iridotomy. (a) Identification. The Nd:YAG laser for... laser intended for disruption of the posterior capsule or the iris via optical breakdown. The Nd:YAG...

  18. 21 CFR 886.4392 - Nd:YAG laser for posterior capsulotomy and peripheral iridotomy.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nd:YAG laser for posterior capsulotomy and...:YAG laser for posterior capsulotomy and peripheral iridotomy. (a) Identification. The Nd:YAG laser for... laser intended for disruption of the posterior capsule or the iris via optical breakdown. The Nd:YAG...

  19. 21 CFR 886.4392 - Nd:YAG laser for posterior capsulotomy and peripheral iridotomy.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nd:YAG laser for posterior capsulotomy and...:YAG laser for posterior capsulotomy and peripheral iridotomy. (a) Identification. The Nd:YAG laser for... laser intended for disruption of the posterior capsule or the iris via optical breakdown. The Nd:YAG...

  20. Application of erbium: YAG laser in ocular ablation.

    PubMed

    Tsubota, K

    1990-01-01

    Recent developments in lasers have provided us the possibility of laser ocular surgery. The xenon, argon, neodymium:YAG and dye lasers have been successfully used in out-patient clinics. The excimer laser has been attracting researchers' interest in the new application of laser to cornea and lens. The erbium:YAG laser emits a 2.94-microns beam that can ablate the transparent ocular tissues such as lenses and corneas. The author has applied this laser to the cornea, lens, vitreous and other ocular tissues. The erbium:YAG laser beam was directed through a 1.5-meter-long, 200-microns-diameter fiberoptic guide. The radiant energy measured about 50 mJ at the end of the probe. The laser was emitted as a 400-microsecond pulse. Freshly enucleated rabbit eyes were used in this study. Laser burns were applied to the tissue surface at various energy settings. At minimal power, the tissues were coagulated by the erbium:YAG laser application. At a power of more than 636-954 mJ/mm2, tissue began to evaporate; the tissue loss was observed under a surgical light microscope. Corneal photoablation, lens ablation, iridotomy, trabeculotomy, cutting of the vitreous and retinal ablation were easily performed. Like the excimer laser, the erbium:YAG laser is a potential tool for ocular surgery.

  1. Reduction of timing jitter in a Q-Switched Nd:YAG laser by direct bleaching of a Cr4+:YAG saturable absorber.

    PubMed

    Cole, Brian; Goldberg, Lew; Trussell, C Ward; Hays, Alan; Schilling, Bradley W; McIntosh, Chris

    2009-02-02

    A method for optical triggering of a Q-switched Nd:YAG laser by direct bleaching of a Cr:YAG saturable absorber is described. This method involves the bleaching of a thin sheet of the saturable absorber from a direction orthogonal to the lasing axis using a single laser diode bar, where the Cr:YAG transmission increased from a non-bleached value of 47% to a bleached value of 63%. For steady state operation of a passively Q-switched laser (PRF=10 Hz), the pulse-to-pulse timing jitter showed approximately 12X reduction in standard deviation, from 241 nsec for free running operation to 20 nsec with optical triggering.

  2. Thermal Shock Behavior of Single Crystal Oxide Refractive Concentrators for High Temperatures Solar Thermal Propulsion

    NASA Technical Reports Server (NTRS)

    Zhu, Dongming; Choi, Sung R.; Jacobson, Nathan S.; Miller, Robert A.

    1999-01-01

    Single crystal oxides such as yttria-stabilized zirconia (Y2O3-ZrO2), yttrium-aluminum-garnet (Y3Al5O12, or YAG), magnesium oxide (MgO) and sapphire (Al2O3) have been considered as refractive secondary concentrator materials for high temperature solar propulsion applications. However, thermal mechanical reliability of the oxide components in severe thermal environments during space mission sun/shade transitions is of great concern. In this paper, critical mechanical properties of these oxide crystals are determined by the indentation technique. Thermal shock resistance of the oxides is evaluated using a high power CO, laser under high temperature-high thermal gradients. Thermal stress fracture behavior and failure mechanisms of these oxide materials are investigated under various temperature and heating conditions.

  3. Growth, structural, optical and thermal properties of gamma-glycine crystal.

    PubMed

    Balakrishnan, T; Babu, R Ramesh; Ramamurthi, K

    2008-04-01

    Single crystals of gamma-glycine were grown from a mixture of glycine, water and lithium bromide. Single crystal X-ray diffraction analysis confirmed the growth of gamma-glycine phase. Presence of various functional groups of gamma-glycine was identified by FTIR spectrum. Optical absorbance spectrum recorded in the wavelength range of UV-vis-NIR revealed that this crystal has good optical transparency in the range 250-1500 nm. Vickers microhardness values were estimated on the prominent (100) face. Thermogravimetric and differential scanning calorimetric analyses were carried out to study the thermal properties of gamma-glycine. Second harmonic generation efficiency of the crystal measured by Kurtz's powder method using Nd:YAG laser is about three times that of KDP.

  4. High-power laser with Nd:YAG single-crystal fiber grown by the micro-pulling-down technique

    NASA Astrophysics Data System (ADS)

    Didierjean, Julien; Castaing, Marc; Balembois, François; Georges, Patrick; Perrodin, Didier; Fourmigué, Jean Marie; Lebbou, Kherreddine; Brenier, Alain; Tillement, Olivier

    2006-12-01

    We present optical characterization and laser results achieved with single-crystal fibers directly grown by the micro-pulling-down technique. We investigate the spectroscopic and optical quality of the fiber, and we present the first laser results. We achieved a cw laser power of 10 W at 1064 nm for an incident pump power of 60 W at 808 nm and 360 kW peak power for 12 ns pulses at 1 kHz in the Q-switched regime. It is, to the best of our knowledge, the highest laser power ever achieved with directly grown single-crystal fibers.

  5. Structural, thermal and optical characterization of an organic NLO material--benzaldehyde thiosemicarbazone monohydrate single crystals.

    PubMed

    Santhakumari, R; Ramamurthi, K

    2011-02-01

    Single crystals of the organic NLO material, benzaldehyde thiosemicarbazone (BTSC) monohydrate, were grown by slow evaporation method. Solubility of BTSC monohydrate was determined in ethanol at different temperatures. The grown crystals were characterized by single crystal X-ray diffraction analysis to determine the cell parameters and by FT-IR technique to study the presence of the functional groups. Thermogravimetric and differential thermal analyses reveal the thermal stability of the crystal. UV-vis-NIR spectrum shows excellent transmission in the region of 200-1100 nm. Theoretical calculations were carried out to determine the linear optical constants such as extinction coefficient and refractive index. Further the optical nonlinearities of BTSC have been investigated by Z-scan technique with He-Ne laser radiation of wavelength 632.8 nm. Mechanical properties of the grown crystal were studied using Vickers microhardness tester. Second harmonic generation efficiency of the powdered BTSC monohydrate was tested using Nd:YAG laser and it is found to be ∼5.3 times that of potassium dihydrogen orthophosphate. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Nd:YAG Laser-aided ceramic brackets debonding: Effects on shear bond strength and enamel surface

    NASA Astrophysics Data System (ADS)

    Han, Xianglong; Liu, Xiaolin; Bai, Ding; Meng, Yao; Huang, Lan

    2008-11-01

    In order to evaluate the efficiency of Nd:YAG laser-aided ceramic brackets debonding technique, both ceramic brackets and metallic brackets were bonded with orthodontic adhesive to 30 freshly extracted premolars. The specimens were divided into three groups, 10 in each, according to the brackets employed and the debonding techniques used: (1) metallic brackets with shear debonding force, (2) ceramic brackets with shear debonding force, and (3) ceramic brackets with Nd:YAG laser irradiation. The result showed that laser irradiation could diminish shear bond strength (SBS) significantly and produce the most desired ARI scores. Moreover, scanning electron microscopy investigation displayed that laser-aided technique induced little enamel scratch or loss. It was concluded that Nd:YAG laser could facilitate the debonding of ceramic brackets and diminish the amount of remnant adhesive without damaging enamel structure.

  7. Cryogenic Yb: YAG Thin-Disk Laser

    DTIC Science & Technology

    2016-09-09

    AFRL-RD-PS- TP-2016-0004 AFRL-RD-PS- TP-2016-0004 CRYOGENIC Yb: YAG THINN-DISK LASER N . Vretenar, et al. 19 August 2011 Technical Paper...Cryogenic Yb: YAG Thin-Disk Laser 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) * N . Vretenar, R. Carson, ***T. Lucas, T. Newell, W.P. Latham...Thin-Disk Laser N . Vretenar,1 T. Carson,2 T. Lucas,3T. Newell,2 W. P. Latham,2 and P. Peterson,3 H. Bostanci,4 J. J. Lindauer4, B. A. Saarloos,4

  8. Multi-wavelength Yb:YAG/Nd3+:YVO4 continuous-wave microchip Raman laser.

    PubMed

    Wang, Xiao-Lei; Dong, Jun; Wang, Xiao-Jie; Xu, Jie; Ueda, Ken-Ichi; Kaminskii, Alexander A

    2016-08-01

    Multi-wavelength continuous-wave (CW) Raman lasers in a laser diode pumped Yb:YAG/Nd3+:YVO4 microchip Raman laser have been demonstrated for the first time to our best knowledge. The multi-wavelength laser of the first Stokes radiation around 1.08 μm has been achieved with a Raman shift of 261  cm-1 for a-cut Nd:YVO4 crystal corresponding to the fundamental wavelength at 1.05 μm. Multi-wavelength laser operation simultaneously around 1.05 and 1.08 μm has been achieved under the incident pump power between 1.5 and 1.7 W. Multi-wavelength Raman laser with frequency separation of 1 THz around 1.08 μm has been obtained when the incident pump power is higher than 1.7 W. The maximum Raman laser output power of 260 mW at 1.08 μm is obtained and the corresponding optical-to-optical conversion efficiency is 4.2%. Elliptically polarized fundamental laser and linearly polarized Raman laser were observed in an Yb:YAG/Nd:YVO4 CW microchip Raman laser. The experimental results of linearly polarized, multi-wavelength Yb:YAG/Nd:YVO4 CW microchip Raman laser with adjustable frequency separation provide a novel approach for developing potential compact laser sources for Terahertz generation.

  9. Efficient Q-switched Tm:YAG ceramic slab laser.

    PubMed

    Zhang, Shuaiyi; Wang, Mingjian; Xu, Lin; Wang, Yan; Tang, Yulong; Cheng, Xiaojin; Chen, Weibiao; Xu, Jianqiu; Jiang, Benxue; Pan, Yubai

    2011-01-17

    Characteristics of Tm:YAG ceramic for high efficient 2-μm lasers are analyzed. Efficient diode end-pumped continuous-wave and Q-switched Tm:YAG ceramic lasers are demonstrated. At the absorbed pump power of 53.2W, the maximum continuous wave (cw) output power of 17.2 W around 2016 nm was obtained with the output transmission of 5%. The optical conversion efficiency is 32.3%, corresponding to a slope efficiency of 36.5%. For Q-switched operation, the shortest width of 69 ns was achieved with the pulse repetition frequency of 500 Hz and single pulse energy of 20.4 mJ, which indicates excellent energy storage capability of the Tm:YAG ceramic.

  10. > 6 MW peak power at 532 nm from passively Q-switched Nd:YAG/Cr4+:YAG microchip laser.

    PubMed

    Bhandari, Rakesh; Taira, Takunori

    2011-09-26

    Megawatt peak power, giant pulse microchip lasers are attractive for wavelength conversion, provided their output is linearly polarized. We use a [110] cut Cr(4+):YAG for passively Q-switched Nd:YAG microchip laser to obtain a stable, linearly polarized output. Further, we optimize the conditions for second harmonic generation at 532 nm wavelength to achieve > 6 MW peak power, 1.7 mJ, 265 ps, 100 Hz pulses with a conversion efficiency of 85%. © 2011 Optical Society of America

  11. Damage thresholds of silica fibers in holmium:YAG laser energy delivery for medical applications

    NASA Astrophysics Data System (ADS)

    Marolda, Matthew D.; Perrault, Donald F., Jr.; Pankratov, Michail M.; Shapshay, Stanley M.

    1993-07-01

    Pulsed Holmium:YAG (Ho:YAG) laser has been approved for some clinical applications and is under investigation for others. There is little published evidence on the durability or damage parameters for the fibers used in delivering energy from pulsed Ho:YAG laser. This study makes an initial attempt to investigate the damage threshold of different silica fibers under various conditions. Three types of fibers supplied by different manufacturers underwent laboratory testing. The overall finding of the study is that a new `perfect' fiber sustains no damage when fired without a target in air or in saline at energies up to 1.5 J/pulse and repetition rate up to 10 Hz. This study suggests that one may need to chose a fiber according to the clinical procedure to be performed: in cases where only soft tissue is to be manipulated - - any fiber may fare well, in cases where bone or calcified tissue is to be lased -- one may need fiber with aluminized or other hard coating. We also conclude that only professional refinishing with the removal of all exposed core-cladding material can insure trouble free performance.

  12. Effect of CO2, Nd:YAG, and Er:YAG lasers on dentin and pulp tissues in dogs

    NASA Astrophysics Data System (ADS)

    Abt, Elliot; Wigdor, Harvey A.; Walsh, Joseph T., Jr.; Brown, Joseph D.

    1992-06-01

    Although there has been interest in lasers in dentistry since lasers were first developed in the early 1960's, this interest was limited until recently. Over the past five years there has been a flurry of interest to find the most effective wavelength and parameters of treatment. With this interest has come clinical and experimental reports. This project is a pilot study to investigate laser effects on dogs teeth. Multiple teeth from 2 dogs (n equals 40) were treated using either a CO2, Nd:YAG, or an Er:YAG laser, or slow-speed rotary instrumentation. One dog died after treatment and was not used in this study. The second dog was sacrificed four days after treatment with the lasers and the teeth were decalcified and processed for light microscopy. The dentin and pulpal tissues were then evaluated for changes from their normal histologic patterns. The purpose of this study was to first determine if the dog would be a good model for in-vivo histologic testing of lasers and second to evaluate the histologic effects of different lasers on dog's teeth. Our findings suggest that each laser causes a different degree of effect to the treated teeth. The specifics of these effects are discussed herein.

  13. Operation of Ho:YAG ultrafast laser inscribed waveguide lasers.

    PubMed

    McDaniel, Sean; Thorburn, Fiona; Lancaster, Adam; Stites, Ronald; Cook, Gary; Kar, Ajoy

    2017-04-20

    We report fabrication and operation of multi-watt level waveguide lasers utilizing holmium-doped yttrium aluminum garnet (Ho:YAG). The waveguides were fabricated using ultrafast laser inscription, which relies on a chirped pulse ytterbium fiber laser to create depressed cladding structures inside the material. A variety of waveguides were created inside the Ho:YAG samples. We demonstrate output powers of ∼2  W from both a single-mode 50 μm waveguide laser and a multimode 80 μm waveguide laser. In addition, laser action from a co-doped Yb:Ho:YAG sample under in-band pumping conditions was demonstrated.

  14. Successful treatment of acne keloidalis nuchae with erbium:YAG laser: a comparative study.

    PubMed

    Gamil, Hend D; Khater, Elsayed M; Khattab, Fathia M; Khalil, Mona A

    2018-05-14

    Acne keloidalis nuchae (AKN) is a chronic inflammatory disease involving hair follicles of the neck. It is a form of keloidal scarring alopecia that is often refractory to medical or surgical management. To evaluate the efficacy of Er:YAG laser in the treatment of AKN as compared to long pulsed Nd:YAG laser. This study was conducted on 30 male patients with AKN. Their ages ranged from 19 to 47 years with a mean age of 36.87 ± 7.8 years. Patients were divided randomly into two groups of 15 patients, each receiving six sessions of either Er:YAG or long-pulsed Nd:YAG laser therapy. A statistically significant decrease in the number of papules was detected at the end of therapy in both groups, with a mean of 91.8% improvement in the Er:YAG group versus 88% in the Nd:YAG group. A significant decrease in plaques count was detected only in the Er: YAG group while a significant decrease in plaques size and consistency was recorded in both groups. The Er: YAG laser proved to be a potentially effective and safe modality both in the early and late AKN lesions.

  15. Growth, structural, thermal, linear and nonlinear optical and laser damage threshold studies of picolinium tartrate monohydrate single crystals.

    PubMed

    Peramaiyan, G; Pandi, P; Sornamurthy, B M; Bhagavannarayana, G; Mohan Kumar, R

    2012-09-01

    Picolinium tartrate monohydrate (PTM), a novel organic nonlinear optical material was synthesized and bulk crystals were grown from aqueous solution by slow cooling technique. The cell parameters of the grown crystal were found by single and powder X-ray diffraction analyses. The crystalline perfection of the grown crystals has been analyzed by high-resolution X-ray diffraction (HRXRD) rocking curve measurements. The presence of functional groups in the grown crystal was identified by FTIR and FT-Raman spectral analyses. UV-Vis spectral studies reveal PTM crystals are transparent in the wavelength region of 295-1100 nm. The thermal characteristics of PTM were analyzed by TGA/DTA studies. The dielectric and mechanical behaviours of PTM crystals were investigated. Dislocation density was estimated to be 2.89 × 10(3) cm(-2) on the flat-surface of PTM crystals from the etching studies. The laser induced surface damage threshold for the grown crystal was measured using Nd:YAG laser. Its second harmonic generation relative efficiency was measured by Kurtz and Perry powder technique and was observed to be comparable with KDP crystal. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Evaluation of the cavity margins after Er:YAG laser ablation of the enamel and dentin

    NASA Astrophysics Data System (ADS)

    Dostalova, Tatjana; Krejsa, Otakar; Jelinkova, Helena; Hamal, Karel

    1994-12-01

    This study investigates the checks of cavity margin after enamel and dentin ablation. The Er:YAG laser enamel and dentin ablation can be directly connected with the danger of cracks originating in the enamel near the cavity. This study evaluates the quality of the enamel edges after Er:YAG laser preparation. The enamel and dentin of buccal surfaces were ablated by the Er:YAG laser radiation. An Erbium:YAG laser system with the energy of 200 mJ was used to generate 200 microsecond(s) long pulses of mid-infrared 2.94 micrometers light in multimode configuration. The laser was operating in a free running mode, the repetition rate being 0.5 Hz with average laser power of 100 mW. Laser radiation was focused on the tooth tissue. Water cooling was used during the procedure in order to prevent tooth tissue destruction. The time of laser preparation was 5 minutes. A cavity of class V was prepared. The teeth were immersed into 0.5% basic fuchsin and then centrifuged at 6000 rev/min for 20 minutes. The microphotographs of the margins stained with 0.5% basic fuchsin were made and then the longitudinal section of the teeth were evaluated. The micrographs of the longitudinal section were checked and measured afterwards. The effect of the investigated laser irradiation on the origin of cracks was analyzed in the scanning electron microscope. Micrographs of each tooth before and after the laser ablation were compared. Micrographs of the intact teeth after extraction present the cracks of the enamel. They depend on the pressure exerted during extraction. The influence of the laser ablation proper is it bears no signs of new cracks. The conclusions of this study demonstrate the non-invasive nature of the Er:YAG laser ablation of the hard dental tissues.

  17. Effects of Different Combinations of Er:YAG Laser-Adhesives on Enamel Demineralization and Bracket Bond Strength.

    PubMed

    Çokakoğlu, Serpil; Nalçacı, Ruhi; Üşümez, Serdar; Malkoç, Sıddık

    2016-04-01

    The purpose of this study was to investigate the demineralization around brackets and shear bond strength (SBS) of brackets bonded to Er:YAG laser-irradiated enamel at different power settings with various adhesive systems combinations. A total of 108 premolar teeth were used in this study. Teeth were assigned into three groups according to the etching procedure, then each group divided into three subgroups based on the application of different adhesive systems. There were a total of nine groups as follows. Group 1: Acid + Transbond XT Primer; group 2: Er:YAG (100 mJ, 10 Hz) etching + Transbond XT Primer; group 3: Er:YAG (200 mJ, 10 Hz) etching + Transbond XT Primer; group 4: Transbond Plus self-etching primer (SEP); group 5: Er:YAG (100 mJ, 10 Hz) etching + Transbond Plus SEP; group 6: Er:YAG (200 mJ, 10 Hz) etching + Transbond Plus SEP; group 7: Clearfil Protect Bond; group 8: Er:YAG (100 mJ, 10 Hz) etching + Clearfil Protect Bond; group 9: Er:YAG (200 mJ, 10 Hz) etching + Clearfil Protect Bond. Brackets were bonded with Transbond XT Adhesive Paste in all groups. Teeth to be evaluated for demineralization and SBS were exposed to pH and thermal cyclings, respectively. Then, demineralization samples were scanned with micro-CT to determine lesion depth values. For SBS test, a universal testing machine was used and adhesive remnant was index scored after debonding. Data were analyzed statistically. No significant differences were found among the lesion depth values of the various groups, except for G7 and G8, in which the lowest values were recorded. The lowest SBS values were in G7, whereas the highest were in G9. The differences between the other groups were not significant. Er:YAG laser did not have a positive effect on prevention of enamel demineralization. When two step self-etch adhesive is preferred for bonding brackets, laser etching at 1 W (100 mJ, 10 Hz) is suggested to improve SBS of brackets.

  18. Nd:YAG-laser-Q-switching with a photo-elastic modulator and applications

    NASA Astrophysics Data System (ADS)

    Bammer, F.; Petkovšek, R.; Dominguez, H.; Liedl, G.

    2010-05-01

    We present a rod-Nd:YAG-Laser, side-pumped with eight 50W-laser diode bars at 808nm, and Q-switched with a Single Crystal Photo-Elastic Modulator at 95.1 kHz. The latter is made of a z-cut LiNbO3-crystal, which is electrically y-excited on the mechanical resonance frequency of the x-longitudinal oscillation. With a voltage amplitude of 3 V the crystal shows a strong oscillation such that due to the photo-elastic effect a high polarization modulation is achieved, which, together with a polarizer, can be used as a simple optical switch. With this inside the laser resonator the average power is 47.8W in cw-mode and 45.5W in pulsed mode, with pulse peak powers of 4 kW and pulse widths of 100ns. This kind of operation is similar to cw-operation but offers due to the high peak powers different interaction physics with matter. The source is therefore suited for micro-welding of metals, LIDAR, rapid prototyping of plastics, marking/engraving/cutting of plastics, marking of glasses. In cases where high precision and a small heat affected zone are necessary this simple kind of pulsed operation may be advantageous, when compared to cw-operation.

  19. Er:YAG laser dentistry in special needs patients

    PubMed Central

    Fornaini, Carlo; Clini, Fabio; Fontana, Matteo; Cella, Luigi; Oppici, Aldo

    2015-01-01

    Objective: Between a quarter and a third of adults with intellectual disability is estimated to have dental anxiety. Unpleasant stimuli, such as the injection of local anaesthesia or the noise and vibration of rotary instruments, may provoke anxiety and subsequent low compliance until the opposition to the treatment. The use of Er:YAG laser in conservative dentistry had a great development in these last years thank to new devices and also to their advantages when compared to the conventional instruments. The aim of this clinical study was to show the advantages of the Er:YAG laser in the conservative treatment of Special Care patients. Methods: Four cases are here described to show the Er:YAG laser use in our Unit on special needs patients. Results and conclusions: Based on the experience gained on conservative laser-assisted treatments performed in a time of 5 years at our Dentistry, Special Needs and Maxillo-Facial Surgery Unit we may affirm that Er:YAG laser may be considered as a good way to improve the cooperation, to reduce anxiety related to rotating instruments and to reach better results with equal or shorter operating times. PMID:26557733

  20. Plasmonic nanoparticles embedded in single crystals synthesized by gold ion implantation for enhanced optical nonlinearity and efficient Q-switched lasing.

    PubMed

    Nie, W J; Zhang, Y X; Yu, H H; Li, R; He, R Y; Dong, N N; Wang, J; Hübner, R; Böttger, R; Zhou, S Q; Amekura, H; Chen, F

    2018-03-01

    We report on the synthesis of embedded gold (Au) nanoparticles (NPs) in Nd:YAG single crystals using ion implantation and subsequent thermal annealing. Both linear and nonlinear absorption of the Nd:YAG crystals have been enhanced significantly due to the embedded Au NPs, which is induced by the surface plasmon resonance (SPR) effect in the visible light wavelength band. Particularly, through a typical Z-scan system excited by a femtosecond laser at 515 nm within the SPR band, the nonlinear absorption coefficients of crystals with Au NPs have been observed to be nearly 5 orders of magnitude larger than that without Au NPs. This giant enhancement of nonlinear absorption properties is correlated with the saturable absorption (SA) effect, which is the basis of passive Q-switching or mode-locking for pulsed laser generation. In addition, the linear and nonlinear absorption enhancement could be tailored by varying the fluence of implanted Au + ions, corresponding to the NP size and concentration modulation. Finally, the Nd:YAG wafer with embedded Au NPs has been applied as a saturable absorber in a Pr:LuLiF 4 crystal laser cavity, and efficient pulsed laser generation at 639 nm has been realized, which presents superior performance to the MoS 2 saturable absorber based system. This work opens an avenue to enhance and modulate the nonlinearities of dielectrics by embedding plasmonic Au NPs for efficient pulsed laser operation.

  1. Phase, compositional, and morphological changes of human dentin after Nd:YAG laser treatment.

    PubMed

    Lin, C P; Lee, B S; Lin, F H; Kok, S H; Lan, W H

    2001-06-01

    Although techniques for repairing root fracture have been proposed, the prognosis is generally poor. If the fusion of a root fracture by laser is possible, it will offer an alternative to extraction. Our group has attempted to use lasers to fuse a low melting-point bioactive glass to fractured dentin. This report is focused on the phase, compositional, and morphological changes observed by means of X-ray diffractometer, Fourier transforming infrared spectroscopy, and scanning electron microscopy-energy dispersive X-ray spectroscopy in human dentin after exposure to Nd:YAG laser. The irradiation energies were from 150 mJ/ pulse-10 pps-4 s to 150 mJ/pulse-30 pps-4 s. After exposure to Nd:YAG laser, dentin showed four peaks on the X-ray diffractometer that corresponding to a-tricalcium phosphate (TCP) and beta-TCP at 20 = 30.78 degrees/34.21 degrees and 32.47 degrees/33.05 degrees, respectively. The peaks of a-TCP and beta-TCP gradually increased in intensity with the elevation of irradiation energy. In Fourier transforming infrared analysis, two absorption bands at 2200 cm(-1) and 2015 cm(-1) could be traced on dentin treated by Nd:YAG laser with the irradiation energies beyond 150 mJ/pulse-10 pps-4 s. The energy dispersive X-ray results showed that the calcium/phosphorus ratios of the irradiated area proportionally increased with the elevation of irradiation energy. The laser energies of 150 mJ/ pulse-30 pps-4 s and 150 mJ/pulse-20 pps-4 s could result in the a-TCP formation and collagen breakdown. However, the formation of glass-like melted substances without a-TCP at the irradiated site was induced by the energy output of 150 mJ/ pulse-10 pps-4 s. Scanning electron micrographs also revealed that the laser energy of 150 mJ/ pulse-10 pps-4 s was sufficient to prompt melting and recrystallization of dentin crystals without cracking. Therefore, we suggest that the irradiation energy of Nd:YAG laser used to fuse a low melting-point bioactive glass to dentin is 150 m

  2. 10-kW-class YAG laser application for heavy components

    NASA Astrophysics Data System (ADS)

    Ishide, Takashi; Tsubota, S.; Nayama, Michisuke; Shimokusu, Yoshiaki; Nagashima, Tadashi; Okimura, K.

    2000-02-01

    The authors have put the YAG laser of the kW class to practical use for repair welding of nuclear power plant steam generator heat exchanger tubes, all-position welding of pipings, etc. This paper describes following developed methods and systems of high power YAG laser processing. First, we apply the 6 kW to 10 kW YAG lasers for welding and cutting in heavy components. The beam guide systems we have used are optical fibers which core diameter is 0.6 mm to 0.8 mm and its length is 200 m as standard one. Using these system, we can get the 1 pass penetration of 15 mm to 20 mm and multi pass welding for more thick plates. Cutting of 100 mm thickness plate data also described for dismantling of nuclear power plants. In these systems we carried out the in-process monitoring by using CCD camera image processing and monitoring fiber which placed coaxial to the YAG optical lens system. In- process monitoring by the monitoring fiber, we measured the light intensity from welding area. Further, we have developed new hybrid welding with the TIG electrode at the center of lens for high power. The hybrid welding with TIG-YAG system aims lightening of welding groove allowances and welding of high quality. Through these techniques we have applied 7 kW class YAG laser for welding in the components of nuclear power plants.

  3. Processing and characterization of polycrystalline YAG (Yttrium Aluminum Garnet) core-clad fibers

    NASA Astrophysics Data System (ADS)

    Kim, Hyun Jun; Fair, Geoff E.; Potticary, Santeri A.; O'Malley, Matthew J.; Usechak, Nicholas G.

    2014-06-01

    Polycrystalline YAG fiber has recently attracted considerable attention for the role it could play as a fiber-laser gain media. This primarily due to its large surface-to-volume ratio, high stimulated Brillouin scattering threshold, and its high thermal conductivity; all of which are superior to that of silica-glass fibers. As a consequence, techniques which enable the fabrication of poly- and single-crystalline YAG fibers have recently been the focus of a number of efforts. In this work we have endeavored to reduce the scattering loss of polycrystalline-YAG-core fibers while simultaneously demonstrating optical gain by enhancing our processing techniques using feedback from mechanical testing and through the development of a technique to encase doped YAG-core fibers with un-doped YAG claddings. To this end we have recently fabricated fibers with both core and claddings made up of polycrystalline YAG and subsequently confirmed that they indeed guide light. In this paper, the processes leading to the fabrication of these fibers will be discussed along with their characterization.

  4. Combination of CO2 and Q-switched Nd:YAG lasers is more effective than Q-switched Nd:YAG laser alone for eyebrow tattoo removal.

    PubMed

    Radmanesh, Mohammad; Rafiei, Zohreh

    2015-04-01

    The eyebrow tattoo removal using Q-switched lasers is usually prolonged. Other modalities may be required to enhance the efficacy and shorten the treatment course. To compare the efficacy of Q-switched neodymium-doped yttrium aluminum garnet (Nd:YAG) laser alone versus combination of Q-switched Nd:YAG and Ultrapulse CO2 lasers for eyebrow tattoo removal after a single session. After local anesthesia, the right eyebrow of 20 patients was treated with Ultrapulse CO2 laser with the parameters of 4 J/cm(2) and 3.2 J/cm(2) for the first and the second passes. Both eyebrows were then treated with 1064-nm and 532-nm Q-switched Nd:YAG laser. The spot size and pulse duration were 3 mm and 5 nanoseconds for both wavelengths, and the fluence was 7 J/cm(2) for 1064 nm and 3 J/cm (2) for 532 nm. The side treated with combination of Q-switched Nd:YAG and CO2 lasers improved 75-100% in 6 of 20 patients versus only 1 of 20 in the side treated with Q-switched Nd:YAG alone. Similarly, the right side in 13 of 20 patients showed more than 50% improvement with combination therapy versus the left side (the monotherapy side), where only 6 of 20 cases showed more than 50% improvement. The Mann-Whitney test was 2.85 for the right side and 1.95 for the left side (P value = 0.007). Using Ultra pulse CO2 laser enhances the efficacy of Q-switched Nd:YAG laser in eyebrow tattoo removal.

  5. Shear Bond Strength of Composite and Ceromer Superstructures to Direct Laser Sintered and Ni-Cr-Based Infrastructures Treated with KTP, Nd:YAG, and Er:YAG Lasers: An Experimental Study.

    PubMed

    Gorler, Oguzhan; Hubbezoglu, Ihsan; Ulgey, Melih; Zan, Recai; Guner, Kubra

    2018-04-01

    The aim of this study was to examine the shear bond strength (SBS) of ceromer and nanohybrid composite to direct laser sintered (DLS) Cr-Co and Ni-Cr-based metal infrastructures treated with erbium-doped yttrium aluminum garnet (Er:YAG), neodymium-doped yttrium aluminum garnet (Nd:YAG), and potassium titanyl phosphate (KTP) laser modalities in in vitro settings. Experimental specimens had four sets (n = 32) including two DLS infrastructures with ceromer and nanohybrid composite superstructures and two Ni-Cr-based infrastructures with ceromer and nanohybrid composite superstructures. Of each infrastructure set, the specimens randomized into four treatment modalities (n = 8): no treatment (controls) and Er:YAG, Nd:YAG, and KTP lasers. The infrastructures were prepared in the final dimensions of 7 × 3 mm. Ceromer and nanohybrid composite was applied to the infrastructures after their surface treatments according to randomization. The SBS of specimens was measured to test the efficacy of surface treatments. Representative scanning electron microscopy (SEM) images after laser treatments were obtained. Overall, in current experimental settings, Nd:YAG, KTP, and Er:YAG lasers, in order of efficacy, are effective to improve the bonding of ceromer and nanohybrid composite to the DLS and Ni-Cr-based infrastructures (p < 0.05). Nd:YAG laser is more effective in the DLS/ceromer infrastructures (p < 0.05). KTP laser, as second more effective preparation, is more effective in the DLS/ceromer infrastructures (p < 0.05). SEM findings presented moderate accordance with these findings. The results of this study supported the bonding of ceromer and nanohybrid composite superstructures to the DLS and Ni-Cr-based infrastructures suggesting that laser modalities, in order of success, Nd:YAG, KTP, and Er:YAG, are effective to increase bonding of these structures.

  6. Evaluation of the bactericidal effect of Nd:YAG, Er:YAG, Er,Cr:YSGG laser radiation, and antimicrobial photodynamic therapy (aPDT) in experimentally infected root canals.

    PubMed

    Cheng, Xiaogang; Guan, Sumin; Lu, Hong; Zhao, Chunmiao; Chen, Xingxing; Li, Na; Bai, Qian; Tian, Yu; Yu, Qing

    2012-12-01

    In recent years, various laser systems have been introduced into the field of laser-assisted endodontic therapy. The aim of this study was to evaluate the bactericidal effect of Nd:YAG, Er:YAG, Er,Cr:YSGG laser radiation, and antimicrobial photodynamic therapy (aPDT) in experimentally infected root canals compared with standard endodontic treatment of 5.25% sodium hypochlorite (NaClO) irrigation. Two hundred and twenty infected root canals from extracted human teeth (contaminated with Enterococcus faecalis ATCC 4083 for 4 weeks) were randomly divided into five experimental groups (Nd:YAG, Er:YAG + 5.25% NaClO + 0.9% normal saline + distilled water (Er:YAG/NaClO/NS/DW), Er:YAG + 0.9% normal saline + distilled water (Er:YAG/NS/DW), Er,Cr:YSGG, and aPDT) and two control groups (5.25% NaClO as positive control and 0.9% normal saline (NS) as negative control). The numbers of bacteria on the surface of root canal walls and at different depths inside dentinal tubules before and after treatment were analyzed by means of one-way analysis of variance (one-way ANOVA). The morphology of bacterial cells before and after treatment was examined by scanning electron microscopy (SEM). After treatment, the bacterial reductions in the experimental groups and the positive control group were significantly greater than that of the negative control group (P < 0.001). However, only Er:YAG/NaClO/NS/DW group showed no bacterial growth (the bacterial reduction reached up to 100%) on the surface of root canal walls or at 100/200 µm inside the dentinal tubules. All the laser radiation protocols tested, especially Er:YAG/NaClO/NS/DW, have effective bactericidal effect in experimentally infected root canals. Er:YAG/NaClO/NS/DW seems to be an ideal protocol for root canal disinfection during endodontic therapy. Copyright © 2012 Wiley Periodicals, Inc.

  7. Laser-diode pumped 40-W Yb:YAG ceramic laser.

    PubMed

    Hao, Qiang; Li, Wenxue; Pan, Haifeng; Zhang, Xiaoyi; Jiang, Benxue; Pan, Yubai; Zeng, Heping

    2009-09-28

    We demonstrated a high-power continuous-wave (CW) polycrystalline Yb:YAG ceramic laser pumped by fiber-pigtailed laser diode at 968 nm with 400 mum fiber core. The Yb:YAG ceramic laser performance was compared for different Yb(3+) ion concentrations in the ceramics by using a conventional end-pump laser cavity consisting of two flat mirrors with output couplers of different transmissions. A CW laser output of 40 W average power with M(2) factor of 5.8 was obtained with 5 mol% Yb concentration under 120 W incident pump power. This is to the best of our knowledge the highest output power in end-pumped bulk Yb:YAG ceramic laser.

  8. Electrically Tunable Nd:YAG waveguide laser based on Graphene

    PubMed Central

    Ma, Linan; Tan, Yang; Akhmadaliev, Shavkat; Zhou, Shengqiang; Chen, Feng

    2016-01-01

    We demonstrate a tunable hybrid Graphene-Nd:YAG cladding waveguide laser exploiting the electro-optic and the Joule heating effects of Graphene. A cladding Nd:YAG waveguide was fabricated by the ion irradiation. The multi-layer graphene were transferred onto the waveguide surface as the saturable absorber to get the Q-switched pulsed laser oscillation in the waveguide. Composing with appropriate electrodes, graphene based capacitance and heater were formed on the surface of the Nd:YAG waveguide. Through electrical control of graphene, the state of the hybrid waveguide laser was turned on or off. And the laser operation of the hybrid waveguide was electrically tuned between the continuous wave laser and the nanosecond pulsed laser. PMID:27833114

  9. Fabrication of optical element from unidirectional grown imidazole-imidazolium picrate monohydrate (IIP) organic crystals for nonlinear optical applications

    NASA Astrophysics Data System (ADS)

    Vivek, P.; Murugakoothan, P.

    2014-12-01

    Nonlinear optical bulk single crystal of Imidazole-imidazolium picrate monohydrate (IIP) has been grown by Sankaranarayanan-Ramasamy (SR) method using acetonitrile as solvent. First time we report the bulk growth of IIP crystal by SR method. The transparent IIP single crystal of maximum diameter 21 mm and length 46 mm was obtained by employing SR method. The grown crystal was subjected to high resolution X-ray diffraction, UV-vis-NIR transmittance, refractive index, hardness, dielectric and laser damage threshold studies. The crystalline perfection of the grown crystal was analyzed using HRXRD. Cut off wavelength and optical transmission window of the crystal was assessed by UV-vis-NIR and the refractive index of the crystal was found. The mechanical property of the crystal was estimated by Vicker's hardness test. The dielectric property of the crystal was measured as a function of frequency. The laser damage threshold value was determined. The particle size dependent second harmonic generation efficiency for IIP was evaluated with standard reference material potassium dihydrogen phosphate (KDP) by Kurtz-Perry powder method using Nd:YAG laser, which established the existence of phase matching. The second harmonic generation (SHG) of IIP crystal was investigated by the SHG Maker fringes technique. The mechanism of growth is revealed by carrying out chemical etching using acetonitrile as etchant.

  10. Can YAG screen accept LEReC bunch train?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seletskiy, S.; Thieberger, P.; Miller, T.

    2016-05-18

    LEReC RF diagnostic beamline is supposed to accept 250 us long pulse trains of 1.6 MeV – 2.6 MeV (kinetic energy) electrons. This beamline is equipped with YAG profile monitor. Since we are interested in observing only the last macro bunch in the train, one of the possibilities is to install a fast kicker and a dedicated dump upstream of the YAG screen (and related diagnostics equipment). This approach is expensive and challenging from engineering point of view. Another possibility is to send the whole pulse train to the YAG screen and to use a fast gated camera (such asmore » Imperex B0610 with trigger jitter under 60ns) to observe the image from the last pulse only. In this paper we study the feasibility of the last approach.« less

  11. Yb:YAG Lasers for Space Based Remote Sensing

    NASA Technical Reports Server (NTRS)

    Ewing, J.J.; Fan, T. Y.

    1998-01-01

    Diode pumped solid state lasers will play a prominent role in future remote sensing missions because of their intrinsic high efficiency and low mass. Applications including altimetry, cloud and aerosol measurement, wind velocity measurement by both coherent and incoherent methods, and species measurements, with appropriate frequency converters, all will benefit from a diode pumped primary laser. To date the "gold standard" diode pumped Nd laser has been the laser of choice for most of these concepts. This paper discusses an alternate 1 micron laser, the YB:YAG laser, and its potential relevance for lidar applications. Conceptual design analysis and, to the extent possible at the time of the conference, preliminary experimental data on the performance of a bread board YB:YAG oscillator will be presented. The paper centers on application of YB:YAG for altimetry, but extension to other applications will be discussed.

  12. Crystal growth and characterization of semi-organic 2-amino-5-nitropyridinium bromide (2A5NPBr) single crystals for third-order nonlinear optical (NLO) applications

    NASA Astrophysics Data System (ADS)

    Vediyappan, Sivasubramani; Arumugam, Raja; Pichan, Karuppasamy; Kasthuri, Ramachandran; Muthu, Senthil Pandian; Perumal, Ramasamy

    2017-12-01

    Semi-organic nonlinear optical (NLO) 2-amino-5-nitropyridinium bromide (2A5NPBr) single crystals have been grown by slow evaporation solution technique (SEST) with the growth period of 60 days. The single-crystal XRD analysis confirms the unit cell parameters of the grown crystal. The crystallinity of grown 2A5NPBr was analyzed by powder X-ray diffraction (PXRD) measurement. The presence of functional groups of 2A5NPBr crystal was confirmed by Fourier transform infrared (FTIR) spectrum analysis. The optical transmittance of the grown crystal was analyzed by UV-Vis-NIR analysis. It shows good transparency in the visible and NIR region and it is favorable for nonlinear optical (NLO) device applications. The chemical etching study was carried out and it reveals that the grown crystal has less dislocation density. The photoconductivity study reveals that the grown crystal possesses positive photoconductive nature. The thermal stability of the crystal has been investigated by thermogravimetric (TG) and differential thermal analysis (DTA). The dielectric constant and dielectric loss as a function of frequency were measured. The electronic polarizability (α) of 2A5NPBr molecule has been calculated theoretically by different ways such as Penn analysis, Clausius-Mossotti relation, Lorentz-Lorenz equation, optical bandgap, and coupled dipole method (CDM). The obtained values of electronic polarizability (α) are in good agreement with each other. Laser damage threshold (LDT) of 2A5NPBr crystal has been measured using Nd:YAG laser with the wavelength of 1064 nm. Third-order nonlinear optical property of the grown crystal was studied by Z-scan technique using He-Ne laser of wavelength 632.8 nm.

  13. 21 CFR 886.4392 - Nd:YAG laser for posterior capsulotomy and peripheral iridotomy.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Parameters: Device must emit a laser beam with the following parameters: wavelength = 1064 nanometers; spot... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nd:YAG laser for posterior capsulotomy and...:YAG laser for posterior capsulotomy and peripheral iridotomy. (a) Identification. The Nd:YAG laser for...

  14. Fractional Er:YAG laser assisting topical betamethasone solution in combination with NB-UVB for resistant non-segmental vitiligo.

    PubMed

    Yan, Ru; Yuan, Jinping; Chen, Hongqiang; Li, Yuan-Hong; Wu, Yan; Gao, Xing-Hua; Chen, Hong-Duo

    2017-09-01

    Resistant non-segmental vitiligo is difficult to be treated. Ablative erbium-YAG (Er:YAG) laser has been used in the treatment of vitiligo, but the ablation of entire epidermis frustrated the compliance of patients. The purpose of this study is to investigate the effects of fractional Er:YAG laser followed by topical betamethasone and narrow band ultraviolet B (NB-UVB) therapy in the treatment of resistant non-segmental vitiligo. The vitiligo lesions of each enrolled patient were divided into four treatment parts, which were all irradiated with NB-UVB. Three parts were, respectively, treated with low, medium, or high energy of Er:YAG laser, followed by topical betamethasone solution application. A control part was spared with laser treatment and topical betamethasone. The treatment period lasted 6 months. The efficacy was assessed by two blinded dermatologists. Treatment protocol with high energy of 1800 mJ/P of fractional Er:YAG laser followed by topical betamethasone solution and in combination with NB-UVB made 60% patients achieve marked to excellent improvement in white patches. The protocol with medium energy of 1200 mJ/P of laser assisted approximate 36% patients achieve such improvement. The two protocols, respectively, showed better efficacies than NB-UVB only protocol. However, fractional Er:YAG laser at low energy of 600 mJ/P did not provide such contributions to the treatment of vitiligo. The fractional Er:YAG laser in combination with topical betamethasone solution and NB-UVB was suitable for resistant non-segmental vitiligo. The energy of laser was preferred to be set at relatively high level.

  15. One Step Combustion Synthesis Of YAG:Ce Phosphor For Solid State Lighting

    NASA Astrophysics Data System (ADS)

    Yadav, Pooja; Gupta, K. Vijay Kumar; Muley, Aarti; Joshi, C. P.; Moharil, S. V.

    2011-10-01

    YAG:Ce is an important phosphor having applications in various fields ranging from solid state lighting to scintillation detectors. YAG phosphors doped with activators are mainly synthesized by solid state reaction techniques that require high sintering temperatures (above 1500°C) to eliminate YAM and YAP phases. Though several soft chemical routes have been explored for synthesis of YAG, most of these methods are complex and phase pure materials are not obtained in one step, but prolonged annealing at temperatures around 1000 C or above becomes necessary. One step combustion synthesis of YAG:Ce3+ and related phosphors carried out at 500 C furnace temperature is reported here. Activation with Ce3+ could be achieved during the synthesis without taking recourse to any post-combustion thermal treatment. LEDs prepared from the combustion synthesized YAG:Ce3+, exhibited properties comparable to those produced from the commercial phosphor.

  16. Effects of Different Combinations of Er:YAG Laser-Adhesives on Enamel Demineralization and Bracket Bond Strength

    PubMed Central

    Nalçacı, Ruhi; Üşümez, Serdar; Malkoç, Sıddık

    2016-01-01

    Abstract Objective: The purpose of this study was to investigate the demineralization around brackets and shear bond strength (SBS) of brackets bonded to Er:YAG laser-irradiated enamel at different power settings with various adhesive systems combinations. Methods: A total of 108 premolar teeth were used in this study. Teeth were assigned into three groups according to the etching procedure, then each group divided into three subgroups based on the application of different adhesive systems. There were a total of nine groups as follows. Group 1: Acid + Transbond XT Primer; group 2: Er:YAG (100 mJ, 10 Hz) etching + Transbond XT Primer; group 3: Er:YAG (200 mJ, 10 Hz) etching + Transbond XT Primer; group 4: Transbond Plus self-etching primer (SEP); group 5: Er:YAG (100 mJ, 10 Hz) etching + Transbond Plus SEP; group 6: Er:YAG (200 mJ, 10 Hz) etching + Transbond Plus SEP; group 7: Clearfil Protect Bond; group 8: Er:YAG (100 mJ, 10 Hz) etching + Clearfil Protect Bond; group 9: Er:YAG (200 mJ, 10 Hz) etching + Clearfil Protect Bond. Brackets were bonded with Transbond XT Adhesive Paste in all groups. Teeth to be evaluated for demineralization and SBS were exposed to pH and thermal cyclings, respectively. Then, demineralization samples were scanned with micro-CT to determine lesion depth values. For SBS test, a universal testing machine was used and adhesive remnant was index scored after debonding. Data were analyzed statistically. Results: No significant differences were found among the lesion depth values of the various groups, except for G7 and G8, in which the lowest values were recorded. The lowest SBS values were in G7, whereas the highest were in G9. The differences between the other groups were not significant. Conclusions: Er:YAG laser did not have a positive effect on prevention of enamel demineralization. When two step self-etch adhesive is preferred for bonding brackets, laser etching at 1 W (100 mJ, 10 Hz) is

  17. Fractionated Er:YAG laser versus fully ablative Er:YAG laser for scar revision: Results of a split scar, double blinded, prospective trial.

    PubMed

    Tidwell, W James; Owen, Cindy E; Kulp-Shorten, Carol; Maity, Abhishek; McCall, Michael; Brown, Timothy S

    2016-11-01

    Ablative laser resurfacing is a common treatment for post-surgical scars. Fractional ablative laser resurfacing has been an emerging treatment option that is replacing fully ablative lasers in many applications. Data comparing fractionated and fully ablative lasers in treating post-operative scars are lacking. Twenty patients were enrolled in a split scar study following excisions from dermatologic surgery. Wounds had to be older than 8 weeks but less than 1 year. The scars were randomly divided into two halves. One half of the scar was treated with fully ablative erbium-doped yttrium aluminum garnet (Er:YAG) and the other was treated with fractionated Er:YAG. The scars were treated at monthly intervals for 3 months, then followed up at months 1 and 2 after the last treatment. POSAS was used to evaluate the scars by a panel of dermatologists blinded to the lasers in conjunction with the patients, who were also blinded. Physicians and patients both observed a superior outcome of 32.5% (P = 0.019) and 58.1% (P = 0.001), respectively, using the POSAS. There was no trend in difference in pain reported by the patient between the two lasers. Patients overwhelmingly preferred the fractionated Er:YAG laser (94%) to the fully ablative laser when asked at the end of the study. Although this study is limited by a short follow-up period, it shows a statistically significant superior outcome in fractionated Er:YAG over fully ablative Er:YAG for scar revision. It also adds quantitative values to the assessment of scar appearance when treated with fractionated lasers compared to fully ablative lasers. It was also found that the fractionated Er:YAG had increased patient satisfaction, but there was no difference in reported pain scores. These data are useful when counseling patients undergoing laser surgery. Lasers Surg. Med. 48:837-843, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Resonantly diode-pumped Er:YAG laser: 1470-nm versus 1530-nm CW pumping case

    NASA Astrophysics Data System (ADS)

    Kudryashov, Igor; Ter-Gabrielyan, Nikolai; Dubinskii, Mark

    2009-05-01

    Growing interest to high power lasers in the eye-safe spectral domain initiated a new wave of activity in developing solid-state lasers based on bulk Er3+-doped materials. The resonant pumping of SSL allows for shifting significant part of thermal load from gain medium itself to the pump diodes, thus greatly reducing gain medium thermal distortions deleterious to SSL power scaling with high beam quality. The two major resonant pumping bands in Er:YAG are centered around 1470 and 1532 nm. Pumping into each of these bands has its pros and contras. The best approach to resonant pumping of Er:YAG active media in terms of pump wavelength is yet to be determined. We report the investigation results of high power diode-pumped Er:YAG laser aimed at direct comparison of resonant pumping at 1470 and 1532 nm. Two sources used for pumping were: 1530-nm 10-diode bar stack (>300 W CW) and 1470-nm 10-diode bar stack (>650 W CW). Both pumps were spectrally narrowed by external volume Bragg gratings. The obtained spectral width of less than 1 nm allowed for 'in-line' pumping of Er3+ in either band. The obtained CW power of over 87 W is, to the best of our knowledge, the record high power reported for resonantly pumped Er:YAG DPSSL at room temperature.

  19. Application of Yb:YAG short pulse laser system

    DOEpatents

    Erbert, Gaylen V.; Biswal, Subrat; Bartolick, Joseph M.; Stuart, Brent C.; Crane, John K.; Telford, Steve; Perry, Michael D.

    2004-07-06

    A diode pumped, high power (at least 20W), short pulse (up to 2 ps), chirped pulse amplified laser using Yb:YAG as the gain material is employed for material processing. Yb:YAG is used as the gain medium for both a regenerative amplifier and a high power 4-pass amplifier. A single common reflective grating optical device is used to both stretch pulses for amplification purposes and to recompress amplified pulses before being directed to a workpiece.

  20. Growth and characterization of unidirectional benzil single crystal for photonic applications

    NASA Astrophysics Data System (ADS)

    Saranraj, A.; Thirupathy, J.; Dhas, S. Sahaya Jude; Jose, M.; Vinitha, G.; Dhas, S. A. Martin Britto

    2018-06-01

    Organic nonlinear optical benzil single crystal of fine quality with the dimensions of 168 × 14 mm2 was successfully grown in (100) plane from saturated solution by unidirectional SR method. The structural identity of the grown crystal was confirmed by powder XRD. High-resolution X-ray diffraction analysis indicates the crystalline perfection of the grown benzil crystal. The optical analysis was carried out by UV-visible spectroscopy which shows that the benzil crystal's cut off wavelength is 437 nm. The dielectric constant and dielectric loss of benzil crystal are found to be very much depending upon temperature and frequency. Ferroelectric nature of grown crystal was identified by P- E hysteresis analysis and to find the values of spontaneous polarization and coercive field. The laser damage threshold energy was studied with the help of Nd:YAG laser. The presence of third harmonic generation was identified by z-scan techniques.

  1. An investigation of the optical properties of cholesterol crystals in human synovial fluid

    NASA Astrophysics Data System (ADS)

    Zakharova, M. M.; Nasonova, V. A.; Konstantinova, A. F.; Chudakov, V. S.; Gaĭnutdinov, R. V.

    2009-05-01

    The synovial fluid of patients with rheumatoid diseases has been investigated. The presence of cholesterol crystals in the synovial fluid is revealed by polarization microscopy. A comparative analysis of the composition and properties of synovial fluid and the optical properties of cholesterol crystals is performed. It is established that the size, number, and growth of cholesterol crystals are interrelated to the synovial fluid composition. It is shown that rheumatoid diseases can be accompanied by the formation of cholesterol crystals in the synovial fluid from different joints and in rheumatic nodules. It is shown that all investigated crystals have a significant birefringence.

  2. Treatment of Melasma with the Photoacoustic Twin Pulse Mode of Low-Fluence 1,064 nm Q-Switched Nd:YAG Laser.

    PubMed

    Kim, Jee Young; Choi, Misoo; Nam, Chan Hee; Kim, Ji Seok; Kim, Myung Hwa; Park, Byung Cheol; Hong, Seung Phil

    2016-06-01

    Low-fluence 1,064 nm Q-switched Nd:YAG laser has been widely used for the treatment of melasma. Although new Q-switched Nd:YAG lasers with photoacoustic twin pulse (PTP) mode have been recently developed for high-efficiency, there is limited information available for the new technique. This study was designed to investigate the efficacy and adverse effects after few sessions of repeated low fluence 1,064 nm Q-switched Nd:YAG laser treatment with PTP mode in Asian women with melasma. Twenty-two Korean women were treated with a total of five sessions of low-fluence PTP mode Nd:YAG laser treatment (Pastelle®) at 2 weeks interval. Responses to treatments were evaluated by using Melasma Area and Severity Index (MASI) scoring, colorimeter measurement, and the investigators' and patients' overall assessments. Adverse events were recorded at each visit. Investigators' and patients' overall assessment showed that 'significantly improved' was assessed by 13 (59.1%) and 19 of 22 patients (86.4%), respectively. MASI scores were significantly reduced by 20.4%. The lightness, measured by using a colorimeter, was significantly increased by 1.3 point. Notable adverse events were not observed. After 5 sessions of laser therapy alone, about 60% of the subjects showed significant improvement. Few sessions of repeated laser toning treatment using the PTP mode is a safe and effective way to treat facial melasma.

  3. Injection-seeded operation of a Q-switched Cr,Tm,Ho:YAG laser

    NASA Technical Reports Server (NTRS)

    Henderson, Sammy W.; Hale, Charley P.; Magee, James R.

    1991-01-01

    Single-frequency Tm,Ho:YAG lasers operating near 2 microns are attractive sources for several applications including eye-safe laser radar (lidar) and pumping of AgGaSe2 parametric oscillators for efficient generation of longer wavelengths. As part of a program to develop a coherent lidar system using Tm,Ho:YAG lasers, a diode laser-pumped tunable CW single-longitudinal-mode (SLM) Cr:Tm:Ho:YAG laser and a flashlamp-pumped single-transverse-mode Q-switched Cr,Tm,Ho:YAG laser were developed. The CW laser was used to injection-seed the flashlamp-pumped laser, resulting in SLM Q-switched output. Operational characteristics of the CW and Q-switched lasers and injection-seeding results are reported.

  4. Synthesis, growth, structural, thermal and optical studies of pyrrolidinium-2-carboxylate-4-nitrophenol single crystals.

    PubMed

    Swarna Sowmya, N; Sampathkrishnan, S; Vidyalakshmi, Y; Sudhahar, S; Mohan Kumar, R

    2015-06-15

    Organic nonlinear optical material, pyrrolidinium-2-carboxylate-4-nitrophenol (PCN) was synthesized and single crystals were grown by slow evaporation solution growth method. Single crystal X-ray diffraction analysis confirmed the structure and lattice parameters of PCN crystals. Infrared, Raman and NMR spectral analyses were used to elucidate the functional groups present in the compound. The thermal behavior of synthesized compound was studied by thermogravimetric and differential scanning calorimetry (TG-DSC) analyses. The photoluminescence property was studied by exciting the crystal at 360 nm. The relative second harmonic generation (SHG) efficiency of grown crystal was estimated by using Nd:YAG laser with fundamental wavelength of 1,064 nm. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Resonantly pumped high efficiency Ho:YAG laser.

    PubMed

    Shen, Ying-Jie; Yao, Bao-Quan; Duan, Xiao-Ming; Dai, Tong-Yu; Ju, You-Lun; Wang, Yue-Zhu

    2012-11-20

    High-efficient CW and Q-switched Ho:YAG lasers resonantly dual-end-pumped by two diode-pumped Tm:YLF lasers at 1908 nm were investigated. A maximum slope efficiency of 74.8% in CW operation as well as a maximum output power of 58.7 W at 83.2 W incident pump power was achieved, which corresponded to an optical-to-optical conversion efficiency of 70.6%. The maximum pulse energy of 2.94 mJ was achieved, with a 31 ns FWHM pulse width and a peak power of approximately 94.7 kW.

  6. Next generation Er:YAG fractional ablative laser

    NASA Astrophysics Data System (ADS)

    Heinrich, A.; Vizhanyo, A.; Krammer, P.; Summer, S.; Gross, S.; Bragagna, T.; Böhler, C.

    2011-03-01

    Pantec Biosolutions AG presents a portable fractional ablative laser system based on a miniaturized diode pumped Er:YAG laser. The system can operate at repetition rates up to 500 Hz and has an incorporated beam deflection unit. It is smaller, lighter and cost efficient compared to systems based on lamp pumped Er:YAG lasers and incorporates a skin layer detection to guarantee precise control of the microporation process. The pulse parameters enable a variety of applications in dermatology and in general medicine, as demonstrated by first results on transdermal drug delivery of FSH (follicle stimulating hormone).

  7. Investigation and characterization of ZnO single crystal microtubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Naser, Qusay A.H.; Zhou, Jian, E-mail: jianzhou@whut.edu.cn; Liu, Guizhen

    2016-04-15

    Morphological, structural, and optical characterization of microwave synthesized ZnO single crystal microtubes were investigated in this work. The structure and morphology of the ZnO microtubes are characterized using X-ray diffraction (XRD), single crystal diffraction (SCD), field emission scanning electron microscopy (FESEM), energy dispersive X-ray spectroscopy (EDX), and transmission electron microscopy (TEM). The results reveal that the as-synthesized ZnO microtube has a highly regular hexagonal cross section and smooth surfaces with an average length of 650–700 μm, an average outer diameter of 50 μm and wall thickness of 1–3 μm, possessing a single crystal wurtzite hexagonal structure. Optical properties of ZnOmore » single crystal microtubes were investigated by photoluminescence (PL) and ultraviolet-visible (UV-vis) absorption techniques. Room-temperature PL spectrum of the microtube reveal a strong UV emission peak at around 375.89 nm and broad and a weak visible emission with a main peak identified at 577 nm, which was assigned to the nearest band-edge emission and the deep-level emission, respectively. The band gap energy of ZnO microtube was found to be 3.27 eV. - Highlights: • ZnO microtube length of 650–700 μm, diameter of 50 μm, wall thickness of 1–3 μm • ZnO microtube possesses a single crystal wurtzite hexagonal structure. • The crystal system is hexahedral oriented along a-axis with indices of (100). • A strong and sharp UV emission at 375.89 nm (3.29 eV) • One prominent absorption band around 378.88 nm (3.27 eV)« less

  8. Genotoxic effects of 1064-nm Nd:YAG and 532-nm KTP lasers on fibroblast cell cultures.

    PubMed

    Senturk, N; Bedir, A; Bilgici, B; Aydin, F; Okuyucu, A; Ozmen, Z C; Turanli, A Y

    2010-07-01

    Several different laser types are used in cutaneous surgery. The neodymium:yttrium-aluminium-garnet (Nd:YAG) and frequency-doubled Nd:YAG (KTP, potassium titanyl phosphate) lasers are widely used in dermatology. To investigate the possible genotoxic effects on fibroblasts of irradiation with a 1064-nm Nd:YAG laser and a 532-nm KTP laser. Fibroblast cell cultures were exposed to each of the lasers, using 10-mm spot size at 60 ms pulse duration with 10, 20, 40 J/cm(2) and 3, 6, 12 J/cm(2) fluences, respectively. Fibroblasts in passages 1-6 were used. During laser irradiation, 96-well microplate cultures were kept on a cooling block and transported on ice and in the dark, and processed immediately for single-cell gel electrophoresis (SCGE) assay (also known as a comet assay). DNA damage was determined by computerized assessment of comet assay. There was increasing damage with increasing numbers of passages. For the Nd:YAG laser, the greatest damage occurred on passages 5 and 6, whereas the greatest damage appeared at passages 3 and 4 for KTP and returned to baseline at passages 5 and 6. Damage also increased with each dose increment for both wavelengths. At the highest dose for both wavelengths (Nd:YAG 40 J/cm(2) and KTP 12 J/cm(2)), damage was higher with the Nd:YAG laser. Different patterns of cellular damage were seen for different cell-culture passages, treatment doses, and laser wavelengths. These dose ranges are generally used for the treatment of vascular and pigmented lesions and for rejuvenation purposes. As replicative ageing or cell senescence is one of the critical factors determining the extent of cell damage induced by laser therapy, these results may have important implications for clinical practice.

  9. Nd:YAG laser therapy for rectal and vaginal venous malformations.

    PubMed

    Gurien, Lori A; Jackson, Richard J; Kiser, Michelle M; Richter, Gresham T

    2017-08-01

    Limited therapeutic options exist for rectal and vaginal venous malformations (VM). We describe our center's experience using Nd:YAG laser for targeted ablation of abnormal veins to treat mucosally involved pelvic VM. Records of patients undergoing non-contact Nd:YAG laser therapy of pelvic VM at a tertiary children's hospital were reviewed. Symptoms, operative findings and details, complications, and outcomes were evaluated. Nine patients (age 0-24) underwent Nd:YAG laser therapy of rectal and/or vaginal VM. Rectal bleeding was present in all patients and vaginal bleeding in all females (n = 5). 5/7 patients had extensive pelvic involvement on MRI. Typical settings were 30 (rectum) and 20-25 W (vagina), with 0.5-1.0 s pulse duration. Patients underwent the same-day discharge. Treatment intervals ranged from 14 to 180 (average = 56) weeks, with 6.1-year mean follow-up. Five patients experienced symptom relief with a single treatment. Serial treatments managed recurrent bleeding successfully in all patients, with complete resolution of vaginal lesions in 40% of cases. No complications occurred. Nd:YAG laser treatment of rectal and vaginal VM results in substantial improvement and symptom control, with low complication risk. Given the high morbidity of surgical resection, Nd:YAG laser treatment of pelvic VM should be considered as first line therapy.

  10. The choice: Welding with CO2 or Nd:YAG lasers

    NASA Astrophysics Data System (ADS)

    Leong, Keng H.

    The recent commercial availability of multi-kilowatt Nd:YAG lasers has opened new avenues for rapid laser processing as well as intensified the competition (cost effectiveness) between CO2 and Nd:YAG laser systems. Vendors offering Nd:YAG laser systems may claim lower operating costs (than CO2) and fiberoptic beam delivery flexibility while CO2 systems vendors may emphasize lower capital cost and well established processing requirements and experience. The capital and operating costs of a laser system are impacted by demand and supply economics and technological advances. Frequently the total cost of a workcell using a laser for processing has to be considered rather than the laser system alone. Consequently it is not very practical to approach the selection of a laser system based on its capital cost and estimated operating cost only. This presentation describes a more pragmatic approach to aid the user in the selection of the optimal multi-kilowatt laser system for a particular processing requirement with emphasis on welding. CO2 laser systems are well established on the factory floor. Consequently, emphasis is given to the comparative application of Nd:YAG lasers, process requirements and performance. Requirements for the laser welding of different metals are examined in the context of hardware (laser system and beam delivery) selection and examples of welding speeds that can be achieved using CO2 and Nd:YAG lasers are examined.

  11. ND:YAG laser for preretinal hemorrhage in diabetic retinopathy.

    PubMed

    Karagiannis, Dimitrios; Kontadakis, Georgios A; Flanagan, Declan

    2018-06-01

    To present fundus images of a case with severe preretinal hemorrhage in diabetic retinopathy that was treated with posterior hyaloidotomy with an Nd:YAG laser. A 35-year-old diabetic patient presented with sudden painless loss of vision due to severe preretinal hemorrhage over the macular area and high risk proliferative diabetic retinopathy. Her visual acuity was counting fingers. Posterior hyaloid face was treated with Nd:YAG laser (posterior hyaloidotomy). Panretinal laser photocoagulation was first performed to control the proliferative diabetic retinopathy. Blood drained inferiorly into the vitreous cavity with clearance of the premacular area. Prompt treatment with Panretinal laser photocoagulation followed by posterior hyaloidotomy with the YAG laser is a viable option in order to avoid further proliferative diabetic retinopathy complications and vision loss. The current image clearly depicts treatment efficacy.

  12. Heat effect of pulsed Er:YAG laser radiation

    NASA Astrophysics Data System (ADS)

    Hibst, Raimund; Keller, Ulrich

    1990-06-01

    Pulsed Er:YAG laser radiation has been found to be effective for dental enamel and dentin removal. Damage to the surrounding hard tissue is little, but before testing the Er:YAG laser clinically for the preparation of cavities, possible effects on the soft tissue of the pulp must be known. In order to estimate pulp damage , temperature rise in dentin caused by the laser radiation was measured by a thermocouple. Additionally, temperature distributions were observed by means of a thermal imaging system. The heat effect of a single Er:YAG laser pulse is little and limited to the vicinity of the impact side. Because heat energy is added with each additional pulse , the temperature distribution depends not only on the radiant energy, but also on the number of pulses and the repetition rate. Both irradiation conditions can be found , making irreversible pulp damage either likely or unlikely. The experimental observations can be explained qualitatively by a simple model of the ablation process.

  13. Growth and characterization of Cadmium Thiosemicarbazide Bromide crystals for antibacterial and nonlinear optical applications

    NASA Astrophysics Data System (ADS)

    Thomas Joseph Prakash, J.; Martin Sam Gnanaraj, J.

    2015-01-01

    Semiorganic nonlinear optical crystals of Cadmium Thiosemicarbazide Bromide was grown by slow evaporation solution growth technique. The unit cell parameters were estimated by subjecting the crystals to single crystal X-ray diffraction. The grown crystals were subjected to Powder X-ray diffraction for analyzing the crystalline nature of the sample. FTIR studies reveal the functional groups and the optical characters were analyzed by UV-Vis spectral studies. Mechanical stability of the sample was assessed by Vicker's micro hardness test. The presence of surface dislocations was identified by chemical etching technique. Antibacterial study was carried out against ACDP declared harmful pathogens. SHG efficiency of CTSB crystal was tested using Nd: YAG laser and it was found to be ∼1.8 times that of potassium dihydrogen phosphate.

  14. Effect of ammonium carbonate to metal ions molar ratio on synthesis and sintering of Nd:YAG nanopowders

    NASA Astrophysics Data System (ADS)

    Liu, Qiang; Chen, Cong; Dai, Jiawei; Hu, Zewang; Chen, Haohong; Li, Jiang

    2018-06-01

    Using the nanopowders synthesized by a reverse co-precipitation method, neodymium doped yttrium aluminum garnet (Nd:YAG) transparent ceramics were fabricated by vacuum sintering method. The influence of ammonium carbonate to metal ions (NH4HCO3/M3+) molar ratio (R value) on the properties of Nd:YAG precursors and powders, as well as the densification, microstructure, and transmittance of the resultant ceramics was systematically investigated. The results show that the precursors have similar compositions and the calcined powders have pure Y3Al5O12 (YAG) phase. However, the R value is closely related to the morphologies of the precursors and powders. It is found that the powder with R = 3.0 has strongest agglomeration and the powders with R = 3.2-4.0 show better dispersity. Using these powders as starting materials, the corresponding ceramics were sintered at 1720 °C for 20 h in vacuum. As a result, the ceramic with R = 3.2 obtains the best transmittance of about 72% at the wavelength of 1064 nm. The grain growth exponent and activation energy of the Nd:YAG ceramics fabricated from the powder with R = 3.2 were also studied.

  15. Lamp pumped Nd:YAG laser. Space-qualifiable Nd:YAG laser for optical communications

    NASA Technical Reports Server (NTRS)

    Ward, K. B.

    1973-01-01

    Results are given of a program concerned with the design, fabrication, and evaluation of alkali pump lamps for eventual use in a space qualified Nd:YAG laser system. The study included evaluation of 2mm through 6mm bore devices. Primary emphasis was placed upon the optimization of the 4mm bore lamp and later on the 6mm bore lamp. As part of this effort, reference was made to the Sylvania work concerned with the theoretical modeling of the Nd:YAG laser. With the knowledge gained, a projection of laser performance was made based upon realistic lamp parameters which should easily be achieved during following developmental efforts. Measurements were made on the lamp performance both in and out of the cavity configuration. One significant observation was that for a constant vapor pressure device, the spectral and fluorescent output did not vary for vacuum or argon environment. Therefore, the laser can be operated in an inert environment (eg. argon) with no degradation in output. Laser output of 3.26 watts at 430 watts input was obtained for an optimized 4mm bore lamp.

  16. Effect of water on dental material ablation of the Er:YAG laser

    NASA Astrophysics Data System (ADS)

    Wigdor, Harvey A.; Visuri, Steven R.; Walsh, Joseph T., Jr.

    1994-09-01

    It is understood that if a laser is to replace the dental high speed handpiece it must be able to ablate dental materials which are present in teeth being treated with the laser. It is the intent of this paper to evaluate the effects of the Er:YAG laser on dental composite restorative material concentrating on the etch rate with and without waterspray. Composite dental material is used to form plugs of known thickness and the etch rate of the Er:YAG laser on this material is determined. The results are compared with those obtained from studies of the Er:YAG on dentin and enamel. In these studies the water reduced the efficiency of the Er:YAG laser 15 - 20% on these tissues.

  17. Diode-side-pumped intracavity frequency-doubled Nd:YAG/BaWO4 Raman laser generating average output power of 3.14 W at 590 nm.

    PubMed

    Li, Shutao; Zhang, Xingyu; Wang, Qingpu; Zhang, Xiaolei; Cong, Zhenhua; Zhang, Huaijin; Wang, Jiyang

    2007-10-15

    We report a linear-cavity high-power all-solid-state Q-switched yellow laser. The laser source comprises a diode-side-pumped Nd:YAG module that produces 1064 nm fundamental radiation, an intracavity BaWO(4) Raman crystal that generates a first-Stokes laser at 1180 nm, and a KTP crystal that frequency doubles the first-Stokes laser to 590 nm. A convex-plane cavity is employed in this configuration to counteract some of the thermal effect caused by high pump power. An average output power of 3.14 W at 590 nm is obtained at a pulse repetition frequency of 10 kHz.

  18. Crystal growth, perfection, linear and nonlinear optical, photoconductivity, dielectric, thermal and laser damage threshold properties of 4-methylimidazolium picrate: an interesting organic crystal for photonic and optoelectronic devices

    NASA Astrophysics Data System (ADS)

    Rajesh, K.; Arun, A.; Mani, A.; Praveen Kumar, P.

    2016-10-01

    The 4-methylimidazolium picrate has been synthesized and characterized successfully. Single and powder x-ray diffraction studies were conducted which confirmed the crystal structure, and the value of the strain was calculated. The crystal perfection was determined by a HRXR diffractometer. The transmission spectrum exhibited a better transmittance of the crystal in the entire visible region with a lower cut-off wavelength of 209 nm. The linear absorption value was calculated by the optical limiting method. A birefringence study was also carried out. Second and third order nonlinear optical properties of the crystal were found by second harmonic generation and the z-scan technique. The crystals were also characterized by dielectric measurement and a photoconductivity analyzer to determine the dielectric property and the optical conductivity of the crystal. The laser damage threshold activity of the grown crystal was studied by a Q-switched Nd:YAG laser beam. Thermal studies established that the compound did not undergo a phase transition and was stable up to 240 °C.

  19. High-average-power CTH:YAG for the medical environment

    NASA Astrophysics Data System (ADS)

    Wright, Sidney P.; Adamkiewicz, Edward J.; Moulton, Peter F.

    1992-06-01

    Medical procedures such as arthroscopy have placed increasing demands on the output performance of the CTH:YAG laser at 2.1 micrometers . Intensive research has been conducted to improve the average power, pulse energies, and rep rates while reducing any failure mechanisms. The results of this work is reported along with a discussion of the important engineering parameters concerning the design of a high power medical CTH:YAG laser.

  20. Optical phase conjugation by four-wave mixing in Nd:YAG laser oscillator for optical energy transfer to a remote target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawakami, K., E-mail: k.kawakami@al.t.u-tokyo.ac.jp; Komurasaki, K.; Okamura, H.

    2015-02-28

    A self-starting phase conjugator was designed for optical energy transfer to a remote target. Saturable-gain four-wave mixing in a laser resonator was achieved using a flash-lamp pumped Nd:YAG crystal and phase-conjugate light (PCL) generation were verified. Wavefront correction experimentation revealed that beam wander caused by air turbulence is compensated. Tracking capability was demonstrated in the range of 9 mrad with tracking accuracy of ±0.04 mrad. The maximum field of view was measured to be 4.7°. Dependence of phase-conjugate light energy on reference light energy was investigated. The maximum output of 320 mJ was obtained. The temporal behavior of PCL ismore » discussed based on the four-wave mixing mechanism. Unlike a conventional loop resonator type phase conjugator, this system is applicable for wireless energy transfer to a remote target.« less

  1. Comparison of Er:YAG and Er:YSGG laser ablation of dental hard tissues

    NASA Astrophysics Data System (ADS)

    Stock, Karl; Hibst, Raimund; Keller, Ulrich

    1997-12-01

    To compare ablation quality of Er:YAG and Er:YSGG laser the surface quality, crater shape, mass loss, and temperature development were determined using the same fiber transmission system and handpiece. Similar crater depths for both lasers but greater diameters for the Er:YAG laser were measured. Also mass loss per pulse of the Er:YAG laser exceeds that of the Er:YSGG laser. Temperature development while ablation of dentin is more pronounced for the Er:YSGG laser. The observed minor ablation quality of the Er:YSGG laser can be explained by the lower absorption coefficient of dental hard substances compared to the Er:YAG laser.

  2. Growth and characterization of Bis(L-threonine) copper (II) monohydrate single crystals: A semiorganic second order nonlinear optical material

    NASA Astrophysics Data System (ADS)

    Subhashini, R.; Sathya, D.; Sivashankar, V.; Latha Mageshwari, P. S.; Arjunan, S.

    2016-12-01

    Highly transparent solitary nonlinear semiorganic optical material Bis(L-threonine) copper (II) monohydrate [BLTCM], was synthesized by a conventional slow evaporation solution growth technique. The grown crystals were subjected to structural, optical, electrical, thermal, mechanical, SHG and Laser damage threshold studies. Single crystal XRD shows that the material crystallizes in monoclinic system with noncentrosymmetric space group P21. FT-IR and FT-RAMAN analyses confirm the various functional groups present in the grown crystal. The transparency range of BLTCM was determined by UV-vis-NIR studies and various optical constants such as extinction coefficient (K), refractive index, optical conductivity and electric susceptibility with real and imaginary parts of dielectric constant were calculated using the transmittance data which have applications in optoelectronic devices. Dielectric studies of the crystal were carried out at different frequencies and temperatures to analyze the electrical properties. TGA and DSC analyses were performed to study the thermal behaviour of the sample. The hardness stability of the grown specimen was investigated by Vickers microhardness test. The output intensity of second harmonic generation was confirmed using the Kurtz and Perry powder method. The laser induced surface damage threshold of the crystal was measured using Nd:YAG laser.

  3. Room temperature operation of 2.67 mJ pulse LD end pumped Q-switched Tm:YAG laser

    NASA Astrophysics Data System (ADS)

    Song, Xuedi; Wu, Chunting; Chen, Xinyu; Yu, Kai; Jin, Guangyong

    2014-12-01

    Due to 2 μm band in the absorption of water and CO2, the diode pumped solid state lasers with wavelength around 2 μm have important applications in laser medicine and remote sensing, such as it can be used as a scalpe or a light source of Coherent Doppler Wind Lidar and Differential Absorption Lidar. In the recently years, scientists have done much work on the development of such lasers. There're many reports on continuous Tm:YAG laser. However, the study on Q-switched Tm:YAG laser, which is more useful in applications, was very rare. As the light source of Coherent Doppler Wind Lidar, large energy and wide pulse width is desired. Current reports mostly adopted CW pumped source, but it would make a mount of heat. Pulse pumping method could reduce the heat accumulation and improve the heat stability of the laser. How to improve the single pulse energy was the focus of current study. In this paper, a single end bonding Tm:YAG crystal with Tm3+ doping concentration of 3.5at.% was used. Acousto-optic (AO) Q-switched (GOOCH and HOUSEGO QS041-10M-HI8) operation was adopted in our experiment. In the repetition frequency of 100Hz, a maximum single energy of 2.67 mJ (measured by Ophir 30A-BB) and the narrowest pulse width of 149 ns (measured by Vigo PCI-3TE-12 detector) were achieved at room temperature. The M2x was 1.31 and the M2y was 1.35 (measured by Spiricon Pyrocam-III). Tm:YAG laser was developed by using a pulse diode pumped L shape resonant cavity. The transmittance of the curve output mirror was 4% and the curvature radius of which was 300 mm. The output center wavelength of the laser was measured to be 2013.5 nm (measured by YOKOGAWA AQ6375).

  4. The threshold effects of Nd and Ho: YAG laser-induced surface modification on demineralization of dentin surfaces.

    PubMed

    Kinney, J H; Haupt, D L; Balooch, M; White, J M; Bell, W L; Marshall, S J; Marshall, G W

    1996-06-01

    Laser irradiation alters the structure of dentin and produces surface layers that give the appearance of being more enamel-like. The laser-modified surface may be more resistant to demineralization; hence, many investigators are proposing continued development of the laser as a possible preventive treatment for caries. The purpose of this study was to explore the morphological changes that occur in dentin when treated at threshold illuminance with two clinically interesting laser wavelengths, and to evaluate the effectiveness of the laser-treated surface at resisting demineralization in an acid-gel solution. The Nd: YAG laser (wavelength 1060 nm) produced significant recrystallization and grain growth of the apatite, without the formation of second phases such as beta-tricalcium phosphate. This recrystallized surface layer showed resistance to demineralization; however, the layer did not provide protection of the underlying dentin from demineralization because of cracks and macroscopic voids that allowed for penetration of the demineralizing gel. The Ho: YAG laser-treated surface (wavelength 2100 nm) did not show significant evidence of recrystallization and grain growth, and only a trace amount of an acid-resistant layer was observed with demineralization. It is speculated that the Ho:YAG laser is coupling with absorbed water, and that the heat transfer from the water to the mineral phase is inefficient. For the purposes of creating a demineralization-resistant layer, threshold illuminance with both Nd: YAG and Ho: YAG was ineffective.

  5. Stone retropulsion during holmium:YAG lithotripsy.

    PubMed

    Lee, Ho; Ryan, R Tres; Teichman, Joel M H; Kim, Jeehyun; Choi, Bernard; Arakeri, Navanit V; Welch, A J

    2003-03-01

    We modeled retropulsion during holmium:YAG lithotripsy on the conservation of momentum, whereby the force of ejected fragment debris off of the calculous surface should equal the force of retropulsion displacing the stone. We tested the hypothesis that retropulsion occurs as a result of ejected stone debris. Uniform calculous phantoms were irradiated with holmium:YAG energy in air and in water. Optical fiber diameter and pulse energy were varied. Motion of the phantom was monitored with high speed video imaging. Laser induced crater volume and geometry were characterized by optical coherence tomography. To determine the direction of plume laser burn paper was irradiated at various incident angles. Retropulsion was greater for phantoms irradiated in air versus water. Retropulsion increased as fiber diameter increased and as pulse energy increased (p <0.001). Crater volumes increased as pulse energy increased (p <0.05) and generally increased as fiber diameter increased. Crater geometry was wide and shallow for larger fibers, and narrow and deeper for smaller fibers. The ejected plume propagated in the direction normal to the burn paper surface regardless of the laser incident angle. Retropulsion increases as pulse energy and optical fiber diameter increase. Vector analysis of the ejected plume and crater geometry explains increased retropulsion using larger optical fibers. Holmium:YAG lithotripsy should be performed with small optical fibers to limit retropulsion.

  6. Calcium oxalate crystal growth modification; investigations with confocal Raman microscopy

    NASA Astrophysics Data System (ADS)

    McMulkin, Calum J.; Massi, Massimiliano; Jones, Franca

    2017-06-01

    Confocal Raman Microscopy (CRM) in combination with a photophysical investigation has been employed to give insight into the interaction between calcium oxalate monohydrate (COM) and a series of tetrazole containing crystal growth modifier's (CGM's), in conjunction with characterisation of morphological changes using scanning electron and optical microscopy. The tetrazole CGM's were found to interact by surface adsorption with minimal morphological changes to the COM crystals however, significant interactions via chemisorption were observed; it was discovered that the chemisorption is sufficiently strong for aggregation of the tetrazole species to occur within the crystal during crystallisation.

  7. EFFECTS OF LASER RADIATION ON MATTER. LASER PLASMA: Thermally induced optical damage to barium-sodium niobate crystals

    NASA Astrophysics Data System (ADS)

    Baryshev, S. A.; Goncharova, I. F.; Konvisar, P. G.; Kuznetsov, V. A.

    1990-06-01

    Thermally induced optical damage (TIOD) was observed in undoped barium-sodium niobate (BSN) crystals as a result of changes in their temperature. This damage was deduced from the behavior of YAG:Nd3+ laser radiation when a BSN crystal was inserted in the resonator and also using a helium-neon laser probe beam. The experimental results were satisfactorily explained by the familiar pyroelectric model of TIOD and, in the crystals studied, an inhomogeneity of the conductivity rather than an inhomogeneity of the pyroelectric constant played the main role.

  8. Growth and characterization of a novel nonlinear optical borate crystal - Yttrium calcium borate (YCB)

    NASA Astrophysics Data System (ADS)

    Arun Kumar, R.; Arivanandhan, M.; Dhanasekaran, R.; Hayakawa, Y.

    2013-06-01

    A new nonlinear optical single crystal yttrium calcium borate Y2CaB10O19 (YCB) was grown for the first time from its melt. The starting materials were prepared by the solid-state reaction method. The melting point of the synthesized material was identified to be 967 °C. YCB crystal exhibits monoclinic crystal structure with the space group C2. The crystalline perfection of the grown YCB crystal was found to be good. From the UV-VIS-NIR studies, the lower cutoff wavelength of the crystal occurs below 200 nm. The functional groups of the grown crystal were assigned using the FTIR data. The second harmonic generation (SHG) of the YCB crystal was observed using a Nd:YAG laser with a fundamental wavelength of 1064 nm. The laser damage threshold value of the YCB crystal was found to be very high - 10.5 GW/cm2.

  9. Dual-laser-beam-induced breakdown spectroscopy of copper using simultaneous continuous wave CO(2) and Q-switched Nd:YAG lasers.

    PubMed

    Shoursheini, S Z; Parvin, P; Sajad, B; Bassam, M A

    2009-04-01

    In this work, we investigate the enhancement of Cu emission lines of a micro-plasma induced by a Nd:YAG laser due to the thermal effect of simultaneous irradiation by a continuous wave (CW) CO(2) laser. The enhancement of the emission lines was achieved at a higher temperature with minimal distortion of the target when the focal point of the Nd:YAG laser was located approximately 1 mm away from the sample surface.

  10. Treatment of Melasma with the Photoacoustic Twin Pulse Mode of Low-Fluence 1,064 nm Q-Switched Nd:YAG Laser

    PubMed Central

    Kim, Jee Young; Choi, Misoo; Nam, Chan Hee; Kim, Ji Seok; Kim, Myung Hwa; Park, Byung Cheol

    2016-01-01

    Background Low-fluence 1,064 nm Q-switched Nd:YAG laser has been widely used for the treatment of melasma. Although new Q-switched Nd:YAG lasers with photoacoustic twin pulse (PTP) mode have been recently developed for high-efficiency, there is limited information available for the new technique. Objective This study was designed to investigate the efficacy and adverse effects after few sessions of repeated low fluence 1,064 nm Q-switched Nd:YAG laser treatment with PTP mode in Asian women with melasma. Methods Twenty-two Korean women were treated with a total of five sessions of low-fluence PTP mode Nd:YAG laser treatment (Pastelle®) at 2 weeks interval. Responses to treatments were evaluated by using Melasma Area and Severity Index (MASI) scoring, colorimeter measurement, and the investigators' and patients' overall assessments. Adverse events were recorded at each visit. Results Investigators' and patients' overall assessment showed that 'significantly improved' was assessed by 13 (59.1%) and 19 of 22 patients (86.4%), respectively. MASI scores were significantly reduced by 20.4%. The lightness, measured by using a colorimeter, was significantly increased by 1.3 point. Notable adverse events were not observed. Conclusion After 5 sessions of laser therapy alone, about 60% of the subjects showed significant improvement. Few sessions of repeated laser toning treatment using the PTP mode is a safe and effective way to treat facial melasma. PMID:27274626

  11. Evaluation of six holmium:YAG optical fibers for ureteroscopy: What's new in 2009?

    NASA Astrophysics Data System (ADS)

    Knudsen, Bodo E.; Teichman, Joel M. H.

    2010-02-01

    The holmium:yttrium aluminum garnet (YAG) laser is the gold standard laser for intracorporeal lithotripsy.1 Optical fibers are utilized to transmit laser energy to the surface of a stone for fragmentation via a predominant photothermal mechanism.2 Previous work has demonstrated that performance characteristics of holmium:YAG optical fibers used for laser lithotripsy varies. Performance may difference not only between fibers made by different manufacturers but also between individual fibers produced by the same manufacturer.3,4 Fiber failure with bending, such as during lower pole ureterorenoscopy, can lead to catastrophic endoscope damage resulting in costly repair. Manufacturers continue to develop new holmium:YAG optical fibers. In this study we evaluate a series of newly commercially available fibers using a previously designed testing protocol. This study was designed to determine the performance and threshold for failure of six newly available holmium:YAG laser fibers from Cook Medical and Fibertech Gmbh. We hypothesize that fiber performance will continue to vary amongst different holmium:YAG optical fibers.

  12. Direct observation of crystal growth from solution using optical investigation of a growing crystal face

    NASA Technical Reports Server (NTRS)

    Lal, Ravindra

    1994-01-01

    The first technical report for the period 1 Jan. 1993 till 31 Dec. 1993 for the research entitled, 'Direct observation of crystal growth from solution using Optical Investigation of a growing crystal Face' is presented. The work on the project did not start till 1 June 1993 due to the non-availability of the required personnel. The progress of the work during the period 1 June 1993 till the end of 1993 is described. Significant progress was made for testing various optical diagnostic techniques for monitoring crystal solution. Some of the techniques that are being tested are: heterodyne detection technique, in which changes in phase are measured as a interferometric function of time/crystal growth; a conventional technique, in which a fringe brightness is measured as a function of crystal growth/time; and a Mach-Zehnder interferometric technique in which a fringe brightness is measured as a function of time to obtain information on concentration changes. During the second year it will be decided to incorporate the best interferometric technique along with the ellipsometric technique, to obtain real time in-situ growth rate measurements. A laboratory mock-up of the first two techniques were made and tested.

  13. Er:YAG Laser Versus Cold Knife Excision in the Treatment of Nondysplastic Oral Lesions: A Randomized Comparative Study for the Postoperative Period.

    PubMed

    Broccoletti, Roberto; Cafaro, Adriana; Gambino, Alessio; Romagnoli, Ercole; Arduino, Paolo Giacomo

    2015-12-01

    The aim of this prospective study was to estimate the effects of Erbium substituted: Yttrium Aluminium Garnet (Er:YAG) laser, compared with traditional scalpel, on the early postoperative sequelae of nondysplastic oral lesion removal. There is limited evidence that laser surgery could exhibit advantages over scalpel in oral mucosal surgery. The investigators studied a cohort of 344 patients; 394 lesions were randomized and treated. Outcome statistically evaluated variables were: age, gender, the site and size of investigated lesions, visual analogue score (VAS) of pain, the Oral Health Impact Profile questionnaire (OHIP-14) and the Quality of Life test (QOL), and number of analgesics taken in the 1st week after surgery. Significant differences were found if considering the surgical time, VAS, and QOL and OHIP-14 questionnaires; regarding those data, the Er:YAG laser appeared to be faster and less painful than traditional scalpel (p < 0.05). For bigger lesions, patients statistically took more painkillers if they had undergone traditional surgery. Considering the site of the treated lesions, Er:YAG laser was less painful, especially in the gingiva and palate (p < 0.05). This is the first randomized controlled surgical trial reported for the management of nondysplastic oral lesions with the use of an Er:YAG laser. With many limitations, the present report identifies significant difference in the immediate postoperative surgical period between the two treatments, meaning that the Er:YAG laser seemed to be less painful, and better accepted by patients, than traditional scalpel.

  14. Theoretical modeling of diode-laser-pumped 3-μm Er3+ crystal lasers

    NASA Astrophysics Data System (ADS)

    Tikerpae, Mark; Jackson, Stuart D.; King, Terence A.

    1997-05-01

    We present results from a theoretical model that has been developed to simulate the 3-micrometer laser transition in Er3+ doped Y3Al5O12 (YAG), Y2Sc2Ga3O12 (YSGG), LiYF4 (YLF) and BaY2F8 (BaYF) host crystals. The rate equations for the lowest seven energy levels of Er3+ were solved numerically and laser action was simulated under cw, gain-switched (pulse pumped) and Q-switched operation with optical pumping at wavelengths of 975 nm and 795 nm. The relative performance of each laser crystal was compared under identical pumping and cavity conditions to establish the optimum crystal host, doping concentration and pump wavelength for each mode of operation. Some unexpected saturation effects were investigated that could limit the maximum practical pump fluence used for high energy Q-switched systems. We investigate possible additional multi-ion energy transfer processes that may cause the decrease in efficiency that is observed experimentally at high Er3+ ion concentrations. In addition, lower laser level deactivation by co-doping with Pr3+ in BaYF was simulated and compared with singly doped Er:BaYF for a range of Er3+ and Pr3+ concentrations. It was found that co-doping was not as effective as the cooperative upconversion process present in singly doped Er3+ crystals for efficient laser operation.

  15. Effect of Er:YAG laser irradiation on bonding property of zirconia ceramics to resin cement.

    PubMed

    Lin, Yihua; Song, Xiaomeng; Chen, Yaming; Zhu, Qingping; Zhang, Wei

    2013-12-01

    This study aimed to investigate whether or not an erbium: yttrium-aluminum-garnet (Er:YAG) laser could improve the bonding property of zirconia ceramics to resin cement. Surface treatments can improve the bonding properties of dental ceramics. However, little is known about the effect of Er:YAG laser irradiated on zirconia ceramics. Specimens of zirconia ceramic pieces were made, and randomly divided into 11 groups according to surface treatments, including one control group (no treatment), one air abrasion group, and nine Er:YAG laser groups. The laser groups were subdivided by applying different energy intensities (100, 200, or 300 mJ) and irradiation times (5, 10, or 15 sec). After surface treatments, ceramic pieces had their surface morphology observed, and their surface roughness was measured. All specimens were bonded to resin cement. Shear bond strength was measured after the bonded specimens were stored in water for 24 h, and additionally aged by thermocycling. Statistical analyses were performed using one way analysis of variance (ANOVA) and Tukey's test for shear bond strength, and Dunnett's t test for surface roughness, with α=0.05. Er:YAG laser irradiation changed the morphological characteristics of zirconia ceramics. Higher energy intensities (200, 300 mJ) could roughen the ceramics, but also caused surface cracks. There were no significant differences in the bond strength between the control group and the laser groups treated with different energy intensities or irradiation times. Air abrasion with alumina particles induced highest surface roughness and shear bond strength. Er:YAG laser irradiation cannot improve the bonding property of zirconia ceramics to resin cement. Enhancing irradiation intensities and extending irradiation time have no benefit on the bond of the ceramics, and might cause material defect.

  16. 15 ps quasi-continuously pumped passively mode-locked highly doped Nd:YAG laser in bounce geometry

    NASA Astrophysics Data System (ADS)

    Jelínek, M., Jr.; Kubeček, V.

    2011-09-01

    A semiconductor saturable absorber mirror mode-locking of a quasi-continuously pumped laser based on 2.4 at.% Nd:YAG slab in a bounce geometry was demonstrated and investigated. Output mode-locked and Q-switched train containing 15 pulses with total energy of 500 μJ was generated directly from the oscillator. The measured 15 ps pulse duration and excellent temporal stability ±2 ps are the best values for pure passively mode-locked and Q-switched Nd:YAG laser with the pulse pumping. Furthermore, using the cavity dumping technique, single 19 ps pulse with energy of 25 μJ was extracted directly from the oscillator.

  17. Compact conductively cooled electro-optical Q-switched Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Li, Chaoyang; Lu, Chengqiang; Li, Chuan; Zang, Yannan; Yang, Zhen; Han, Song; Li, Ye; Yang, Ning; Shi, Junfeng; Zhou, Zewu

    2017-11-01

    We report on a compact conductively cooled high-repetition-rate nanosecond Nd:YAG laser. The oscillator was an laser diode side-pumped electro-optical (EO) Q-switched Nd:YAG rod laser adopting unstable cavity with a variable reflectivity mirror. A pulse train of 142 mJ with duration of 10 ns, repetition rate of 80 Hz at 1064 nm has been achieved. Maximum pulse energy was obtained at the pump energy of 1380 mJ, corresponding to the optical-optical conversion efficiency of 10.3%. The peak power was deduced to be 14.2 MW. The near-field pattern demonstrated a nearly super Gaussian flat top profile. To our knowledge, this is the highest repetition rate operation for a conductively cooled EO Q-switched Nd:YAG rod laser.

  18. Treatment of patients with OSAS using Nd-YAG laser

    NASA Astrophysics Data System (ADS)

    Kukwa, Andrzej; Tulibacki, Marek P.; Zajac, Andrzej; Dudziec, Katarzyna

    2000-06-01

    The authors present their clinical experience regarding the possibilities of application of Nd:YAG and Ho:YAG lasers for the treatment of disorders in the are of the upper respiratory tract. The patients with symptoms of Obstructive Sleep Aphnoe Syndrom need a various operations techniques. Lasers techniques makes it possible to perform a number of procedures in local anesthesia which considerably improves the economic effectiveness of the treatment. The surgeries performed using laser beam enabled very good effect of treatment.

  19. On the use of a chirped Bragg grating as a cavity mirror of a picosecond Nd : YAG laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zubko, A E; Shashkov, E V; Smirnov, A V

    2016-02-28

    The first experimental evidence is presented that the use of a chirped volume Bragg grating (CVBG) as a cavity mirror of a Q-switched picosecond Nd : YAG laser with self-mode-locking leads to significant changes in the temporal parameters of the laser output. Measurements have been performed at two positions of the CVBG: with the grating placed so that shorter wavelengths reflected from its front part lead longer wavelengths or with the grating rotated through 180°, so that longer wavelengths are reflected first. In the former case, the duration of individual pulses in a train increased from ∼35 to ∼300 ps,more » whereas the pulse train shape and duration remained the same as in the case of a conventional laser with a mirror cavity. In the latter case, the full width at half maximum of pulse trains increased from ∼70 ns (Nd : YAG laser with a mirror cavity) to ∼1 ms, and the duration of individual pulses increased from 35 ps to ∼1.2 ns, respectively, which is more typical of free-running laser operation. (laser crystals and braggg ratings)« less

  20. Vapor emissions resulting from Nd:YAG laser interaction with tooth structure.

    PubMed

    Gelskey, S C; White, J M; Gelskey, D E; Kremers, W

    1998-11-01

    The Neodymium:yttrium aluminum garnet (Nd:YAG) dental laser has been cleared by the United States Food and Drug Administration (FDA) for marketing in intraoral soft tissue treatment. The efficacy and safety of the Nd:YAG laser in the treatment of hard dental tissue as well as the effects of dental irradiation on the pulp and periodontium have been investigated. Odors resulting from laser irradiation have been reported, but the nature and toxicity of associated decomposition vapors is unknown and the health consequences of their inhalation have not yet been studied. The purpose of this in vitro study was to identify vapors emitted during interaction of the Nd:YAG laser with carious human enamel and dentin and sound enamel and dentin coated with organic ink. Vapor emissions were collected from prepared sections of extracted human teeth receiving laser irradiation of 100 mJ and 10 Hz for a duration of 1, 10, or 60 s. Emissions were collected by means of charcoal absorption tubes, and subsequently analyzed using a Gas Chromatograph equipped with Mass Selective (GC/MS) and Flame Ionization Detectors to identify the chemical constituents of the vapors. No compounds were identified in Nd:YAG laser-treated caries, enamel and dentin. No volatile vapors were identified from samples of tooth materials exposed to the laser for 1 or 10 s. Camphor was positively identified in the test sample which consisted of India ink-coated dentin and the reference sample of India ink-coated glass beads, both exposed to the laser for 60 s. 2,5-norbornadiene was tentatively identified in these samples. The Threshold Limit Value (TLV) of camphor is 2 ppm with a Lethal Dose Level (LDLo) of 50 mg/kg (human oral), while the TLV and LDLo of 2,5-norbornadiene is unknown. Occupational and public health safety measures are discussed in this article. Further research is needed to quantify the compounds produced and to determine their toxicity to patients and to dental care providers.

  1. Changes in nail keratin observed by Raman spectroscopy after Nd:YAG laser treatment.

    PubMed

    Shin, Min Kyung; Kim, Tae In; Kim, Wan Sun; Park, Hun-Kuk; Kim, Kyung Sook

    2017-04-01

    Lasers and photodynamic therapy have been considered a convergence treatment for onychomycosis, which is a fungal infection on the nail bed and nail plate. Laser therapies have shown satisfactory results without significant complications for onychomycosis; however, the mechanism of clearing remains unknown. In this work, we investigated changes in the chemical structure of nail keratin induced by Nd:YAG laser using Raman spectroscopy. Toe nails with onychomycosis were treated with 1064 nm Nd:YAG laser. After laser treatment, the disulfide band (490-590 cm -1 ) of nail keratin was rarely observed or was reduced in intensity. The amide I band (1500-1700 cm -1 ) also showed changes induced by the laser. The α-helical (1652 cm -1 ) structures dominated the β-sheet (1673 cm -1 ) in nontreated nail, but the opposite phenomenon was observed after laser treatment. © 2016 Wiley Periodicals, Inc.

  2. NdYag Laser for Acne Keloidalis Nuchae

    ClinicalTrials.gov

    2013-03-27

    Acne Keloidalis Nuchae; NdYag Laser; AKN; Acne Keloidalis; AK; Dermatitis Papillaris Capillitii; Folliculitis Keloidalis Nuchae; Sycosis Nuchae; Acne Keloid; Keloidal Folliculitis; Lichen Keloidalis Nuchae; Folliculitis Nuchae Scleroticans; Sycosis Framboesiformis

  3. Synthesis and physicochemical properties of bis(L-asparaginato) zinc(II): A promising new semiorganic crystal with high laser damage threshold for shorter wavelength generation

    NASA Astrophysics Data System (ADS)

    Subhashini, R.; Arjunan, S.

    2018-05-01

    An exceedingly apparent nonlinear semiorganic optical crystals of bis(L-asparaginato)zinc(II) [BLAZ], was synthesized by a traditional slow evaporation solution growth technique. The cell parameters were estimated from single crystal X-ray diffraction analysis. Spectroscopic study substantiates the presence of functional groups. The UV spectrum shows the sustenance of wide transparency window and several optical constants, such as extinction coefficient (K), refractive index, optical conductivity and electric susceptibility with real and imaginary parts of dielectric constant were calculated using the transmittance data. The fluorescence emission spectrum of the crystal pronounces red emission. The laser induced surface damage threshold of the crystal was measured using Nd:YAG laser. The output intensity of second harmonic generation was estimated using the Kurtz and Perry powder method. The hardness stability was investigated by Vickers microhardness test. The decomposition and thermal stability of the compound were scrutinized by TGA-DSC studies. Dielectric studies were carried out to anatomize the electrical properties of the crystal. SEM analysis reveals the existence of minute crystallites on the growth surface.

  4. Vortex operation in Er:LuYAG crystal laser at ∼1.6 μm

    NASA Astrophysics Data System (ADS)

    Liu, Qiyao; Zhao, Yongguang; Zhou, Wei; Shen, Deyuan

    2017-09-01

    An Er3+-doped Lu1.5Y1.5Al5O12 (Er:LuYAG) solid-state laser with direct generation of optical vortex is reported. The vortex laser operation was realized through being pumped by an annular beam at 1532 nm, which was reformatted by a specially fabricated optical mirror. With two different laser output couplers of 10% and 20% transmissions, pure LG01 mode lasers with right-handedness at 1647.7 nm and 1619.5 nm were yielded from a simple two-mirror cavity, respectively, without any helicity control optical element. Furthermore, stable pulse trains at 1647.7 nm have been achieved via employing an acousto-optic Q-switch, and ∼0.66 mJ pulsed energy and ∼65 ns pulse duration were finally obtained at 1 kHz repetition rate, corresponding to a peak power of ∼10.2 kW. The generated pulse vortex maintained LG01 mode with well-determined right-handedness, as in the case of cw laser operation.

  5. Acute and chronic response of meniscal fibrocartilage to holmium:YAG laser irradiation

    NASA Astrophysics Data System (ADS)

    Horan, Patrick J.; Popovic, Neven A.; Islinger, Richard B.; Kuklo, Timothy R.; Dick, Edward J.

    1997-05-01

    The acute and chronic (10 week) histological effects of the holmium:YAG laser during partial meniscectomy in an in vivo rabbit model were investigated. Twenty-four adult male New Zealand rabbits underwent bilateral parapatellar medial knee arthrotomies. In the right knee, a partial medial meniscectomy was done through the avascular zone using a standard surgical blade. In the left knee, an anatomically similar partial medial meniscectomy was performed using a Ho:YAG laser (Coherent, USA). This study indicates that the laser creates two zones of damage in the meniscal fibrocartilage and that the zone of thermal change may act as a barrier to healing. The zone of thermal change which is eventually debrided was thought at the time of surgery to be viable. In the laser cut menisci, the synovium appears to have greater inflammation early and to be equivalent with the scalpel cut after three weeks. At all time periods there appeared more cellular damage in the laser specimens.

  6. Idler-resonant intracavity KTA-based OPO pumped by a dual-loss modulated-Q-switched-laser with AOM and Cr4+:YAG

    NASA Astrophysics Data System (ADS)

    Qiao, Junpeng; Zhao, Shengzhi; Yang, Kejian; Zhao, Jia; Li, Guiqiu; Li, Dechun; Li, Tao; Qiao, Wenchao

    2017-06-01

    An idler-resonant KTiOAsO4 (KTA)-based intracavity optical parametric oscillator (IOPO) pumped by a dual-loss-modulated Q-switched laser with an acousto-optic modulator (AOM) and a Cr4+:YAG saturable absorber (Cr4+:YAG-SA) has been presented. By utilizing a type-II non-critically phase-matched KTA crystal, signal wave at 1535 nm and idler wave at 3467 nm have been generated. Under an incident pump power of 18.3 W, maximum output powers of 615 mW for signal wave and 228 mW for idler wave were obtained at an AOM modulation rate of 10 kHz, corresponding to a whole optical-to-optical conversion efficiency of 4.6%. The shortest pulse widths of signal and idler wave were measured to be 898 ps and 2.9 ns, corresponding to the highest peak powers of 68.4 and 7.9 kW, respectively. In comparison with IOPO pumped by a singly Q-switched laser with an AOM, the IOPO pumped by a doubly Q-switched laser (DIOPO) with an AOM and a Cr4+:YAG-SA can generate signal wave and idler wave with shorter pulse width and higher peak power. By considering the spatial Gaussian distribution of intracavity photon density, a set of coupled rate equations for the idler-resonant DIOPO were built for the first time to the best of our knowledge. The simulation results agreed well with the experimental results.

  7. Crystal growth, physical properties and computational insights of semi-organic non-linear optical crystal diphenylguanidinium perchlorate grown by conventional solvent evaporation method

    NASA Astrophysics Data System (ADS)

    Kajamuhideen, M. S.; Sethuraman, K.; Ramamurthi, K.; Ramasamy, P.

    2018-02-01

    A splendid nonlinear optical single crystals diphenylguanidinium perchlorate (DPGP) was lucratively grown by low cost solvent evaporation method with the dimensions of 8 × 4 × 2 mm3. Structural and morphological studies of grown crystal were confirmed using X-ray diffraction studies. The presence of diverse functional groups was identified using FTIR and RAMAN studies. The molecular structure of a grown crystal was inveterate by NMR studies. The optical transmittance of DPGP crystal was analyzed using UV-vis-NIR studies. Photoluminescence spectrum shows sharp, well defined emission peak at 388 nm. Thermal studies assign that adduct is stable with the melting point of 164 °C. Microhardness studies declare that DPGP crystal belongs to the soft material class and their yield strength and elastic stiffness constant values were evaluated. Photoconductivity studies revealed the negative photoconductive nature of DPGP crystal. Second harmonic generation (SHG) efficiency of the DPGP crystal was 1.4 times that of potassium dihydrogen phosphate. Etching studies were carried out for different etching time. The dielectric studies were performed at different frequency. Laser damage threshold properties of DPGP crystal were examined using Nd:YAG laser system. The HOMO-LUMO energy gap evident the charge transfer interaction of the molecule. The calculated first order hyperpolarizability value is 5 times greater than that of urea. Thus, the grown DPGP single crystals are well suited for NLO device fabrications.

  8. Treatment of vitreous floaters with neodymium YAG laser.

    PubMed Central

    Tsai, W F; Chen, Y C; Su, C Y

    1993-01-01

    Fifteen cases of vitreous floaters with serious psychological reactions have been collected. By using a direct ophthalmoscope, causal vitreous opacities were detected. The opacities were photodisrupted with neodymium YAG laser, using energy levels of 5 to 7.1 mJ and total energy 71 to 742.0 mJ. Symptoms completely disappeared immediately after treatment in all 15 cases. There were no intraoperative or postoperative complications noted during a follow up period of at least 1 year. To our knowledge, the use of neodymium YAG laser to treat vitreous floaters has not been previously described. Our initial experience indicates that the treatment is simple, safe, and effective. Images PMID:8025044

  9. Retinal damage from a Q-switched YAG laser.

    PubMed

    Jampol, L M; Goldberg, M F; Jednock, N

    1983-09-01

    A 42-year-old woman with sickle cell anemia and proliferative retinopathy underwent neodymium-YAG laser therapy for a taut posterior hyaloid membrane causing peripapillary and peripheral traction detachment of the retina. Vitrectomy was not done because the patient required anticoagulation. A Q-switched YAG laser was capable of cutting holes in the taut membrane, but treatment 2 to 3 mm from the retina resulted in microperforation of a retinal vein and focal areas of damage to the retinal pigment epithelium. The damage to the retinal pigment epithelium was not immediately apparent, and ophthalmoscopically visible lesions were seen only when the patient was reexamined 48 hours later.

  10. Comparison of diode laser and Er:YAG lasers in the treatment of ankyloglossia.

    PubMed

    Aras, Mutan Hamdi; Göregen, Mustafa; Güngörmüş, Metin; Akgül, Hayati Murat

    2010-04-01

    The purpose of this study was to compare the tolerance of lingual frenectomy with regard to a local anesthesia requirement and comparison of postsurgical discomfort experienced by patients operated on with both diode and erbium:yttrium-aluminium-garnet (Er:YAG) lasers. Ankyloglossia, commonly known as tongue-tie, is a congenital oral anomaly characterized by a short lingual frenulum. A short lingual frenulum may contribute to feeding, speech, and mechanical tongue problems. Sixteen referred patients with tongue mobility complaints were included in this study. A GaAlAs laser device with a continuous wavelength of 808 nm was used in the diode group. Frenulums were incised by applying 2 W of laser power. The Er:YAG laser device with a continuous wavelength of 2940 nm was used in the Er:YAG group. Frenulums were incised by applying 1 W of laser power. The acceptability of the lingual frenectomy without local anesthesia and the degree of the postsurgical discomfort were evaluated. Although the majority of patients (six) could be operated on without local anesthesia in the Er:YAG group, all patients could not be operated on without local anesthetic agent in the diode group. There were no differences between the two groups with regard to pain, chewing, and speaking on the first or seventh day after surgery, whereas patients had more pain in the Er:YAG group than in the diode group the first 3 h after surgery. The results indicate that only the Er:YAG laser can be used for lingual frenectomy without local anesthesia, and there was no difference between the two groups regarding the degree of the postsurgical discomfort except in the first 3 h. In conclusion, these results indicate that the Er:YAG laser is more advantageous than the diode laser in minor soft-tissue surgery because it can be performed without local anesthesia and with only topical anesthesia.

  11. Dual-wavelength, continuous-wave Yb:YAG laser for high-resolution photothermal common-path interferometry.

    PubMed

    Zhuang, Fengjiang; Jungbluth, Bernd; Gronloh, Bastian; Hoffmann, Hans-Dieter; Zhang, Ge

    2013-07-20

    We present a continuous-wave (CW) intracavity frequency-doubled Yb:YAG laser providing 1030 and 515 nm output simultaneously. This laser system was designed for photothermal common-path interferometry to measure spatially resolved profiles of the linear absorption in dielectric media and coatings for visible or infrared light as well as of the nonlinear absorption for the combination of both. A Z-shape laser cavity was designed, providing a beam waist in which an LBO crystal was located for effective second-harmonic generation (SHG). Suitable frequency conversion parameters and cavity configurations were discussed to achieve the optimal performance of a diode-pumped CW SHG laser. A 12.4 W 1030 nm laser and 5.4 W 515 nm laser were developed simultaneously in our experiment.

  12. Response of feline intradental nerve fibers to tooth cutting by Er:YAG laser.

    PubMed

    Chaiyavej, S; Yamamoto, H; Takeda, A; Suda, H

    2000-01-01

    The aim of this study was to investigate the response of intradental A- and C-fibers during tooth cutting by Er:YAG laser. Bipolar electrical stimulation was applied to the cat's canine to identify functional single nerve fibers of the inferior alveolar nerve. The tip of the canine tooth was cut in 0.5-mm steps until the pulp was exposed. Teeth were alternately cut by using Er:YAG laser (50 mJ, 5 pps) and micromotor under water cooling. The nerve response recorded from the single nerve fibers during laser cutting was compared with that during micromotor cutting. All 26 A-fibers responded to laser cutting with high frequency of nerve firings. The nerve firing rate was significantly higher during laser cutting compared with that during micromotor cutting of superficial dentin (Chi(2) test, P < 0.05) but was not significantly different at deep dentin (P > or = 0. 05). Nine of 11 C-fibers responded to laser cutting when the deep dentin was cut. Among those nine nerve fibers, three also showed a low frequency response to laser cutting of the superficial dentin. During the tooth cutting, Er:YAG laser was more effective in activating intradental A-fibers compared with micromotor and also caused the activation of intradental C-fibers. Copyright 2000 Wiley-Liss, Inc.

  13. Nd:YAG laser-induced morphology change and photothermal conversion of gold nanorods with potential application in the treatment of port-wine stain.

    PubMed

    Xing, Linzhuang; Chen, Bin; Li, Dong; Ma, Jun; Wu, Wenjuan; Wang, Guoxiang

    2017-04-01

    Based on the principle of selective photothermolysis, 1064 nm Nd:YAG laser has great potential for the treatment of deeper and larger PWS. However, the clinical effectiveness is limited because of the weak absorption of blood to Nd:YAG laser. The aim of this study is to obtain the optimal irradiation conditions to effectively destroy vascular lesions with the assistance of PEG-modified gold NRs to enhance blood absorption of Nd:YAG laser. In our study, PEG-modified gold NRs were prepared by the seeded growth method. Gold NRs after exposure to Nd:YAG laser were characterized using absorption spectra and transmission electron microscope images. The tissue-like phantom containing a glass capillary with blood was prepared and exposed to Nd:YAG laser to investigate the laser energy density and pulse number required for blood coagulation before and after the addition of gold NRs in blood. The results show that the millisecond Nd:YAG laser irradiation does not result in the shape change of gold NRs. After injection of gold NRs into the bloodstream (4.60 mg/kg), the absorbance of blood at 1064 nm increased 3.9 times. The threshold energy density for the treatment of PWS decreased by 33% (from 30 to 20 J/cm 2 ). Our findings provide an experimental guide for choosing laser parameters and gold NRs concentration for the treatment of deeper and larger PWS with the assistance of PEG-modified gold NRs in vivo in the future.

  14. Er:YAG delamination of immersed biological membranes using sealed flexible hollow waveguides

    NASA Astrophysics Data System (ADS)

    Sagi-Dolev, A. M.; Dror, Jacob; Inberg, Alexandra; Ferencz, J. R.; Croitoru, Nathan I.

    1996-04-01

    The radiation of Er-YAG laser ((lambda) equals 2.94 micrometer) gives selective interaction with tissues. The extinction in soft tissues is only a few micrometers and in hard tissues is of the order of hundreds of micrometers. This makes this type of laser very suitable for treatments in dentistry, orthopedy, or ophthalmology. Because the usual silica fibers are not transmitting the radiation at lambda equals 2.94 micrometer of this laser, many applications cannot be presently performed. Fused silica hollow fibers for Er-YAG radiation were developed in our laboratory and several possible applications in dentistry, orthopedy and ophthalmology were indicated. Hole opening and implantation preparation of teeth were experimented, using Er-YAG laser and hollow plastic waveguide delivery systems. Hole drilling in cow bones was demonstrated for applications in orthopedy. A new procedure of delivering Er-YAG radiation on fibrotic membranes of inner eggshell as a model of the membranes in eyes was developed employing silica hollow waveguides of 0.5 and 0.7 mm ID or a plastic waveguide of 1.0 mm ID. For this purpose waveguides with sealed distal tip were employed to enable us to approach the delivery system through liquid media near to the membrane. This experiment demonstrates the possibility of surgical applications in vitectomy in ophthalmology using Er-YAG laser and silica hollow waveguides.

  15. Cumulative probability of neodymium: YAG laser posterior capsulotomy after phacoemulsification.

    PubMed

    Ando, Hiroshi; Ando, Nobuyo; Oshika, Tetsuro

    2003-11-01

    To retrospectively analyze the cumulative probability of neodymium:YAG (Nd:YAG) laser posterior capsulotomy after phacoemulsification and to evaluate the risk factors. Ando Eye Clinic, Kanagawa, Japan. In 3997 eyes that had phacoemulsification with an intact continuous curvilinear capsulorhexis, the cumulative probability of posterior capsulotomy was computed by Kaplan-Meier survival analysis and risk factors were analyzed using the Cox proportional hazards regression model. The variables tested were sex; age; type of cataract; preoperative best corrected visual acuity (BCVA); presence of diabetes mellitus, diabetic retinopathy, or retinitis pigmentosa; type of intraocular lens (IOL); and the year the operation was performed. The IOLs were categorized as 3-piece poly(methyl methacrylate) (PMMA), 1-piece PMMA, 3-piece silicone, and acrylic foldable. The cumulative probability of capsulotomy after cataract surgery was 1.95%, 18.50%, and 32.70% at 1, 3, and 5 years, respectively. Positive risk factors included a better preoperative BCVA (P =.0005; risk ratio [RR], 1.7; 95% confidence interval [CI], 1.3-2.5) and the presence of retinitis pigmentosa (P<.0001; RR, 6.6; 95% CI, 3.7-11.6). Women had a significantly greater probability of Nd:YAG laser posterior capsulotomy (P =.016; RR, 1.4; 95% CI, 1.1-1.8). The type of IOL was significantly related to the probability of Nd:YAG laser capsulotomy, with the foldable acrylic IOL having a significantly lower probability of capsulotomy. The 1-piece PMMA IOL had a significantly higher risk than 3-piece PMMA and 3-piece silicone IOLs. The probability of Nd:YAG laser capsulotomy was higher in women, in eyes with a better preoperative BCVA, and in patients with retinitis pigmentosa. The foldable acrylic IOL had a significantly lower probability of capsulotomy.

  16. Endobronchial occlusive disease: Nd:YAG or PDT?

    NASA Astrophysics Data System (ADS)

    Regal, Anne-Marie; Takita, Hiroshi

    1991-06-01

    Patients with endobronchial occlusion commonly experience dyspnea, cough, hemoptysis, pneumonitis, and atelectasis. If luminal patency is not re-established, obstructive symptoms may progress to sepsis and death. Although the overall survival of patients with lung cancer may not be altered by relief of airway obstruction, the prognosis for this subset of patients may be improved by eliminating the septic complications of bronchial occlusion. Techniques to treat occluded bronchi include electro-fulguration, cryotherapy, brachytherapy, laser (CO2, Nd-YAG) therapy, and photodynamic therapy (PDT). These represent local forms of treatment and are intended to be palliative. Nd-YAG and PDT are the modalities more frequently utilized in this setting. Comparison of the two treatment forms may furnish insight regarding the appropriate role for each as individual therapies and as part of the armamentarium of cancer therapies.

  17. Hollow-core photonic-crystal fibres for laser dentistry.

    PubMed

    Konorov, Stanislav O; Mitrokhin, Vladimir P; Fedotov, Andrei B; Sidorov-Biryukov, Dmitrii A; Beloglazov, Valentin I; Skibina, Nina B; Wintner, Ernst; Scalora, Michael; Zheltikov, Aleksei M

    2004-04-07

    Hollow-core photonic-crystal fibres (PCFs) for the delivery of high-fluence laser radiation capable of ablating tooth enamel are developed. Sequences of picosecond pulses of 1.06 microm Nd:YAG-laser radiation with a total energy of about 2 mJ are transmitted through a hollow-core photonic-crystal fibre with a core diameter of approximately 14 microm and are focused on a tooth surface in vitro to ablate dental tissue. The hollow-core PCF is shown to support the single-fundamental-mode regime for 1.06 microm laser radiation, serving as a spatial filter and allowing the laser beam quality to be substantially improved. The same fibre is used to transmit emission from plasmas produced by laser pulses on the tooth surface in the backward direction for detection and optical diagnostics.

  18. Growth and characterization of Yb:Ho:YAG single crystal fiber

    NASA Astrophysics Data System (ADS)

    Yang, Yilun; Ye, Linhua; Bao, Renjie; Li, Shanming; Zhang, Peixiong; Xu, Min; Hang, Yin

    2018-06-01

    High quality Yb and Ho co-doped Y3Al5O12 single crystal fibers have been successfully grown by the laser heated pedestal growth method of up to 124 mm in length and 450 μm in diameter for the first time. The results of inductively coupled plasma-atomic emission spectrometry analysis, X-ray diffraction and Raman spectroscopy reveal that the lattice structure and doping concentrations of the SCF are the same as that of the bulk. Scanning electron microscopy microphotographs shows that the fibers only have minor diameter fluctuations within 0.5%.

  19. Studies on the growth aspects, structural, thermal, dielectric and third order nonlinear optical properties of solution grown 4-methylpyridinium p-nitrophenolate single crystal

    NASA Astrophysics Data System (ADS)

    Devi, S. Reena; Kalaiyarasi, S.; Zahid, I. MD.; Kumar, R. Mohan

    2016-11-01

    An ionic organic optical crystal of 4-methylpyridinium p-nitrophenolate was grown from methanol by slow evaporation method at ambient temperature. Powder and single crystal X-ray diffraction studies revealed the crystal system and its crystalline perfection. The rocking curve recorded from HRXRD study confirmed the crystal quality. FTIR spectral analysis confirmed the functional groups present in the title compound. UV-visible spectral study revealed the optical window and band gap of grown crystal. The thermal, electrical and surface laser damage threshold properties of harvested crystal were examined by using TGA/DTA, LCR/Impedance Analyzer and Nd:YAG laser system respectively. The third order nonlinear optical property of grown crystal was elucidated by Z-scan technique.

  20. 2D SiNx photonic crystal coated Y3Al5O12:Ce3+ ceramic plate phosphor for high-power white light-emitting diodes.

    PubMed

    Park, Hoo Keun; Oh, Jeong Rok; Do, Young Rag

    2011-12-05

    This paper reports the optical effects of a two-dimensional (2D) SiNx photonic crystal layer (PCL) on Y3Al5O12:Ce3+ (YAG:Ce) yellow ceramic plate phosphor (CPP) in order to enhance the forward emission of YAG:Ce CPP-capped high-power white light-emitting diodes (LEDs). By adding the 2D SiNx PCL with a 580 nm lattice constant, integrated yellow emission was improved by a factor of 1.72 compared to that of a conventional YAG:Ce CPP capped on a blue LED cup. This enhanced forward yellow emission is attributed to increased extraction of yellow emission light and improved absorption of blue excitation light through Bragg scattering and/or the leaky modes produced by the 2D PCLs. The introduction of 2D PCL can also reduce the wide variation of optical properties as a function of both ambient temperature and applied current, compared to those of a high-power YAG:Ce CPP-capped LED.

  1. Retinotomy using an erbium:YAG laser on human autopsy eyes

    NASA Astrophysics Data System (ADS)

    Ellsworth, Lansing G.; Kramer, Theresa R.; Noecker, Robert J.; Snyder, Robert W.; Yarborough, J. Michael

    1994-06-01

    Mid-IR lasers that operate near the absorption peak of water have a short penetration depth in ocular tissues. Ablation of tissue can be accomplished with minimal coagulative damage to underlying structures. We used an erbium:YAG laser equipped with a contact probe to create retinotomy sites in the human retina of eye bank eyes. An erbium:YAG laser (2.94 micrometers ) equipped with an infrared transmitting glass fiber and a sapphire tip (400 micrometers ) was used to directly ablate the surface of the retina. We administered both single and multiple pulses to the macula and peripheral retina using energy levels from 4 to 16 mJ per pulse. The retinas were then examined histopathologically to evaluate the extent of ablation and coagulative damage. Single pulses at low energy levels were noted to cause ablative damage to the nerve fiber layer and ganglion cell layer without a notable coagulative effect. The mean ablation depth at lower energy levels was less than the mean ablation depth at higher energy levels. Extensive laser application produced disruption of the retinal pigment epithelium, choroid and sclera. the erbium:YAG laser equipped with a contact probe is an effective means of creating retinotomies in human autopsy eyes. When used in the single pulse mode at lower energy levels, the erbium:YAG laser appears capable of removing superficial retinal layers without damaging deeper structures.

  2. Low threshold CW Nc laser oscillator at 1060 nm study

    NASA Technical Reports Server (NTRS)

    Birnbaum, M.; Deshazer, L. G.

    1976-01-01

    A broad range of characteristics of neodymium/yag lasers were investigated. With Nd:YVO4 crystals, CW 1.06 mu lasers were operated with thresholds a factor of 2 lower than Nd:YAG and with greater slope efficiencies. Thus, the first step in the development of new oscillators suitable for application in high data rate laser communication systems which surpass the present performance of the Nd:YAG laser has been successfully demonstrated.

  3. Crystal growth, thermal and optical studies of semiorganic nonlinear optical material: L-lysine hydrochloride dihydrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalaiselvi, D.; Mohan Kumar, R.; Jayavel, R.

    2008-07-01

    Single crystals of L-lysine hydrochloride dihydrate (LLHCD), a nonlinear optical material, have been grown by slow cooling technique from its aqueous solution. LLHCD was found to be highly soluble in water. The grown crystals have been subjected to single crystal X-ray diffraction to confirm the structure and to estimate the lattice parameters. The vibrational structure of the molecule is elucidated from FTIR spectra. Thermal analysis revealed the thermal stability of the grown crystals. The optical transmittance spectrum shows that the material possesses good optical transparency in the entire visible region with a UV cut-off wavelength at 228 nm. The mechanicalmore » properties of the grown crystal have been studied using Vicker's microhardness test. The laser damage threshold of 52.25 MW/cm{sup 2} has been measured by irradiating Q-switched Nd:YAG laser (1064 nm)« less

  4. Directly diode-pumped high-energy Ho:YAG oscillator.

    PubMed

    Lamrini, Samir; Koopmann, Philipp; Schäfer, Michael; Scholle, Karsten; Fuhrberg, Peter

    2012-02-15

    We report on the high-energy laser operation of an Ho:YAG oscillator resonantly pumped by a GaSb-based laser diode stack at 1.9 μm. The output energy was extracted from a compact plano-concave acousto-optically Q-switched resonator optimized for low repetition rates. Operating at 100 Hz, pulse energies exceeding 30 mJ at a wavelength of 2.09 μm were obtained. The corresponding pulse duration at the highest pump power was 100 ns, leading to a maximum peak power above 300 kW. Different pulse repetition rates and output coupling transmissions of the Ho:YAG resonator were studied. In addition, intracavity laser-induced damage threshold measurements are discussed.

  5. Nd:YAG development for spaceborne laser ranging system

    NASA Technical Reports Server (NTRS)

    Harper, L. L.; Logan, K. E.; Williams, R. H.; Stevens, D. A.

    1979-01-01

    The results of the development of a unique modelocked laser device to be utilized in future NASA space-based, ultraprecision laser ranger systems are summarized. The engineering breadboard constructed proved the feasibility of the pump-pulsed, actively modelocked, PTM Q-switched Nd:YAG laser concept for the generation of subnanosecond pulses suitable for ultra-precision ranging. The laser breadboard also included a double-pass Nd:YAG amplifier and provision for a Type II KD*P frequency doubler. The specific technical accomplishment was the generation of single 150 psec, 20-mJ pulses at 10 pps at a wavelength of 1.064 micrometers with 25 dB suppression of pre-and post-pulses.

  6. Optimization of diode-pumped doubly QML laser with neodymium-doped vanadate crystals at 1.34 μm

    NASA Astrophysics Data System (ADS)

    Zhang, Gang; Jiao, Zhiyong

    2018-05-01

    We present a theoretical model for a diode-pumped, 1.34 μm V3+:YAG laser that is equipped with an acoustic-optic modulator. The model includes the loss introduced by the acoustic-optic modulator combined with the physical properties of the laser resonator, the neodymium-doped vanadate crystals and the output coupler. The parameters are adjusted within a reasonable range to optimize the pulse output characteristics. A typical Q-switched and mode-locked Nd:Lu0.15Y0.85VO4 laser at 1.34 μm with acoustic-optic modulator and V3+:YAG is set up, and the experimental output characteristics are consistent with the theoretical simulation results.

  7. Soft tissue effects of the THC:YAG laser on canine vocal cords.

    PubMed

    Kay, S L; Oz, M C; Haber, M; Blitzer, A; Treat, M R; Trokel, S L

    1992-09-01

    Recently, a laser based on a thulium-holmium-chromium (THC) doped Yttrium-aluminum-garnet (YAG) rod has been developed that produces light of 2.15 microns wavelength and can be transmitted through a low OH- silica fiberoptic cable. This wavelength falls on one of the peaks of the energy absorption spectrum of water. Thus, the THC:YAG laser eliminates the disadvantage of a cumbersome delivery system found in the CO2 laser while still providing precise cutting and minimal tissue injury inherent in lasers emitting light absorbed by water. We evaluated the soft tissue effects of this laser on canine vocal cords. Ablative lesions were produced by the THC:YAG laser and histologically examined on postoperative days 1, 7, and 28. Results indicate that the depth of tissue penetration is easily controlled and the healing response to tissue injury is comparable to that of the CO2 laser. The THC:YAG laser should prove to be a superior laser for use in otorhinolaryngology, especially when adapted to a flexible endoscope.

  8. Cystoscopic suture removal by Holmium-YAG laser after Burch procedure

    PubMed Central

    Karaşahin, Emre Kazım; Esin, Sertaç; Alanbay, İbrahim; Ercan, Mutlu Cihangir; Mutlu, Erol; Başer, İskender; Basal, Şeref

    2011-01-01

    Burch colposuspension remains one of the successful operations performed for stress incontinence. Accidental suturing of the bladder wall during the procedure or subsequent erosion may lead to lower urinary tract symptoms. Diagnosis and management of these sutures indicate precise evaluation for which a 70 degree cystoscope is used. In selected cases, Holmium-YAG laser may enable us to manage long-standing, encrustated neglected sutures. Here we would like to report successful removal of intravesical sutures using the Holmium-YAG laser. PMID:24591960

  9. Scintillation properties of Pr 3+-doped lutetium and yttrium aluminum garnets: Comparison with Ce 3+-doped ones

    NASA Astrophysics Data System (ADS)

    Mares, Jiri A.; Nikl, Martin; Beitlerova, Alena; Blazek, Karel; Horodysky, Petr; Nejezchleb, Karel; D'Ambrosio, Carmelo

    2011-12-01

    Scintillation properties of Pr 3+-doped LuAG and YAG crystals were investigated and compared with those of Ce 3+-doped ones. The highest L.Y.'s were observed with the longest shaping time 10 μs. They can reach up to ˜16,000 ph/MeV or ˜23,500 ph/MeV for LuAG:Pr and LuAG:Ce, respectively. Energy resolutions (FWHM) are a bit better with LuAG:Pr than those of LuAG:Ce, e.g. at 662 keV FWHM are around 6% and between 8-12%, respectively. There were observed no large changes in proportionality of Pr 3+- or Ce 3+-doped LuAG or YAG crystals but the best proportionality has YAP:Ce crystal. Pr 3+- or Ce 3+-doped LuAG crystals exhibit slow decay components in the time range 1.5-3.5 μs while those of YAG ones have shorter decay components between 0.3-1.7 μs.

  10. Improvement of the technique in treatment of internal hemorrhoids with Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Bao, Xiao-qing; Zhu, Jing; Shi, Hong-Min

    2005-07-01

    Objective: To observe and study the improvement of the technique in treatment of internal hemorrhoids with Nd:YAG laser and evaluate the effective rate. Methods: 60 patients of internal hemorrhoids were treated with Nd:YAG laser (10-15mw) irradiating on the mucosa of the lesions. Results: Among 60 patients, 57 patients were primarily cured with one treatment, 3 patients were primarily cured with two treatments. The effective rate was 95% with one treatment, and it reached to 100% with two treatments. Conclusions: the improvement of the technique in treatment of internal hemorrhoids with Nd:YAG laser is effective and easy to operate.

  11. Phase conjugation of Nd:YAG laser radiation

    NASA Astrophysics Data System (ADS)

    Chen, Jun

    1988-06-01

    The phase conjugation of Nd:YAG laser radiation by four-wave mixing in silicon and by stimulated Brillouin scattering in acetone and other organic liquids was experimentally and theoretically investigated. Due to nonlinear absorption in Si a saturation of the reflection of the phase conjugator was theoretically predicted, and experimentally observed. It is theoretically and experimentally shown that the radiation profile behind the Si-sample is annular due to defocusing. The experiments show that CS2 and acetone have the lowest thresholds for stimulated Brillouin scattering. A laser resonator was built using a Brillouin cell and two normal mirrors; the emitted laser beam is insensitive to phase perturbations in the resonator, and has a pulse duration of 5 ns and a pulse energy of 220 m.

  12. Influence of tartaric acid on linear-nonlinear optical and electrical properties of KH2PO4 crystal

    NASA Astrophysics Data System (ADS)

    Baig, M. I.; Anis, Mohd; Muley, G. G.

    2017-10-01

    KH2PO4 (KDOP) is widely demanded technological crystal for applications in laser driven photonic devices. Therefore, present article is focused to investigate the effect of tartaric acid (TA) on laser induced nonlinear optical properties of KDOP crystal. The optically transparent TA doped KDOP crystal of size 15 × 10 × 04 mm3 has been grown by slow solvent evaporation technique at 35 °C. The structural analysis of pure and TA doped KDOP crystal has been achieved by means of single crystal X-ray diffraction technique. The functional groups of TA doped KDOP crystal has been identified by means of Fourier transform infrared spectral analysis. The UV-visible studies have been performed to determine the optical transparency and evaluate the linear optical constants of pure and TA doped KDOP crystal. The Kurtz-Perry test has been employed to confirm the frequency doubling phenomenon of crystal and the SHG efficiency of TA doped KDOP crystal is found to be 5.68 times higher than that of standard KDP material. The Z-scan technique has been employed to explore the third order nonlinear optical (TONLO) refraction (n2), absorption (β) and susceptibility (χ3) of pure and TA doped KDOP crystal at 632.8 nm. The TA facilitated optical switching in TONLO response of KDOP crystal is found to be an interesting effect to examine. The laser damage threshold of TA doped KDOP crystal has been determined at 1064 nm using the Nd:YAG laser. The comparative electrical analysis on pure and TA doped KDOP crystal has been accomplished by means of dielectric and photoconductivity characterization studies.

  13. Laser emission from diode-pumped Nd:YAG ceramic waveguide lasers realized by direct femtosecond-laser writing technique.

    PubMed

    Salamu, Gabriela; Jipa, Florin; Zamfirescu, Marian; Pavel, Nicolaie

    2014-03-10

    We report on realization of buried waveguides in Nd:YAG ceramic media by direct femtosecond-laser writing technique and investigate the waveguides laser emission characteristics under the pump with fiber-coupled diode lasers. Laser pulses at 1.06 μm with energy of 2.8 mJ for the pump with pulses of 13.1-mJ energy and continuous-wave output power of 0.49 W with overall optical efficiency of 0.13 were obtained from a 100-μm diameter circular cladding waveguide realized in a 0.7-at.% Nd:YAG ceramic. A circular waveguide of 50-μm diameter yielded laser pulses at 1.3 μm with 1.2-mJ energy.

  14. Analysis of Shear Bond Strength and Morphology of Er:YAG Laser-Recycled Ceramic Orthodontic Brackets.

    PubMed

    Han, Ruo-qiao; Yang, Kai; Ji, Ling-fei; Ling, Chen

    2016-01-01

    The aim of this study was to compare the recycling of deboned ceramic brackets via an Er:YAG laser or via the traditional chairside processing methods of flaming and sandblasting; shear bond strength and morphological changes were evaluated in recycled brackets versus new brackets. 3M Clarity Self-Ligating Ceramic Brackets with a microcrystalline base were divided into groups subjected to flaming, sandblasting, or exposure to an Er:YAG laser. New ceramic brackets served as a control group. Shear bond strengths were determined with an Electroforce test machine and tested for statistical significance through analysis of variance. Morphological examinations of the recycled ceramic bracket bases were conducted with scanning electron microscopy and confocal laser scanning microscopy. Residue on the bracket base was analyzed with Raman spectroscopy. Faded, dark adhesive was left on recycled bracket bases processed via flaming. Adhesive was thoroughly removed by both sandblasting and exposure to an Er:YAG laser. Compared with new brackets, shear bond strength was lower after sandblasting (p < 0.05), but not after exposure to an Er:YAG laser. The Er:YAG laser caused no damage to the bracket. Er:YAG lasers effectively remove adhesive from the bases of ceramic brackets without damaging them; thus, this method may be preferred over other recycling methods.

  15. Periodontal tissue healing following flap surgery using an Er:YAG laser in dogs.

    PubMed

    Mizutani, Koji; Aoki, Akira; Takasaki, Aristeo Atsushi; Kinoshita, Atsuhiro; Hayashi, Chie; Oda, Shigeru; Ishikawa, Isao

    2006-04-01

    The purpose of this study was to compare periodontal tissue healing following flap surgery using an Er:YAG laser with that of conventional surgery. Bilateral premolars with experimentally induced periodontitis in six dogs were treated by periodontal flap surgery. Degranulation and root debridement in the furcation were performed using an Er:YAG laser or curet. At 3 months postsurgery, animals were sacrificed and decalcified specimens were prepared for histological and histometric analysis. Degranulation and root debridement were effectively performed with an Er:YAG laser without major thermal damage and significantly faster than with a curet. Histologically, the amount of newly formed bone was significantly greater in the laser group than in the curet group, although both groups showed similar amounts of cementum formation and connective tissue attachment. The Er:YAG laser irradiation can be safely and effectively utilized in periodontal flap surgery, and has the potential to promote new bone formation. Copyright 2006 Wiley-Liss, Inc.

  16. Low-threshold ablation of enamel and dentin using Nd:YAG laser assisted with chromophore with different pulse shapes

    NASA Astrophysics Data System (ADS)

    Bonora, Stefano; Benazzato, Paolo; Stefani, Alessandro; Villoresi, Paolo

    2004-05-01

    Neodimium laser treatment has several drawbacks when used in the hard tissue cutting, because of the low absorption of the dental tissues at its wavelength. This investigation proved that the Nd:YAG radiation is a powerful ablation tool if it is used with the dye assisted method. Several in vitro tests on enamel and dentin were accomplished changing some laser parameters to have different pulse shapes and durations from 125μs up to 1.4ms. The importance of short time high power peaks, typical of crystal lasers, in the ablation process was investigated. The pulse shapes were analyzed by their intensity in space and time profiles. A first set of results found the optimum dye concentration be used in all the following tests. Furthermore the ablation threshold for this technique was found for each different pulse shapes and durations. A low energy ablation method was found to avoid temperature increase and surface cracks formation. In vitro temperature analysis was reported comparing the differences between no dye application laser treatment and with a dye spray applied. A strong reduction of the temperature increase was found in the dye assisted method. A discussion on the general findings and their possible clinical applications is presented.

  17. Efficacy of percutaneous treatment of biliary tract calculi using the holmium:YAG laser.

    PubMed

    Hazey, J W; McCreary, M; Guy, G; Melvin, W S

    2007-07-01

    Few Western studies have focused on percutaneous techniques using percutaneous transhepatic choledochoscopy (PTHC) and holmium:yttrium-aluminum-garnet (YAG) laser to ablate biliary calculi in patients unable or unwilling to undergo endoscopic or surgical removal of the calculi. The authors report the efficacy of the holmium:YAG laser in clearing complex biliary calculi using percutaneous access techniques. This study retrospectively reviewed 13 non-Asian patients with complex secondary biliary calculi treated percutaneously using holmium:YAG laser. Percutaneous access was accomplished via left, right, or bilateral hepatic ducts and upsized for passage of a 7-Fr video choledochoscope. Lithotripsy was performed under choledochoscopic vision using a holmium:YAG laser with 200- or 365-microm fibers generating 0.6 to 1.0 joules at 8 to 15 Hz. Patients underwent treatment until stone clearance was confirmed by PTHC. Downsizing and subsequent removal of percutaneous catheters completed the treatment course. Seven men and six women with an average age of 69 years underwent treatment. All the patients had their biliary tract stones cleared successfully. Of the 13 patients, 3 were treated solely as outpatients. The average length of percutaneous access was 108 days. At this writing, one patient still has a catheter in place. The average number of holmium:YAG laser treatments required for stone clearance was 1.6, with no patients requiring more than 3 treatments. Of the 13 patients, 8 underwent a single holmium:YAG laser treatment to clear their calculi. Prior unsuccessful attempts at endoscopic removal of the calculi had been experienced by 7 of the 13 patients. Five patients underwent percutaneous access and subsequent stone removal as their sole therapy for biliary stones. Five patients were cleared of their calculi after percutaneous laser ablation of large stones and percutaneous basket retrieval of the remaining stone fragments. There was one complication of pain

  18. Investigation of magnesium fluoride crystals for imaging acousto-optic tunable filter applications.

    PubMed

    Voloshinov, Vitaly B; Gupta, Neelam

    2006-05-01

    Results of an investigation of acousto-optic (AO) cells using single crystals of magnesium fluoride (MgF2) are presented. Two acousto-optic tunable filter (AOTF) cells for imaging application have been designed and tested in the visible and ultraviolet (UV) regions of the spectrum from 190 to 490 nm. The two imaging filters were developed by using the wide-angle AO interaction geometry in the (010) and (11 0) planes of the crystal. These filters were used to obtain spectral images at the shortest wavelengths achieved so far. Advantages and drawbacks of this crystal are discussed and photoelastic, acoustic, and AO properties of MgF2 are examined. The investigation confirmed that MgF2-based AOTF cells can be used in the deep UV region up to 110 nm.

  19. Platelet derived growth factor secretion and bone healing after Er:YAG laser bone irradiation.

    PubMed

    Kesler, Gavriel; Shvero, Dana Kesler; Tov, Yariv Siman; Romanos, George

    2011-03-01

    Er:YAG laser irradiation has been reported to enhance wound healing. However, no studies have evaluated the synthesis of growth factors after laser irradiation. The present study investigated the effects of laser irradiation on the amount of secretion of platelet derived growth factor (PDGF) in the wound, clarifying the effects of the Er:YAG laser on the bone healing. Osteotomies were prepared in the tibiae of 28 rats using an Er:YAG laser (test group). Maximum power of 8 watts, energy per pulse of 700 mJ, and frequency up to 50 Hz were used. The laser was used with external water irrigation, a spot size of 2 mm, energy per pulse of 500 to 1000 mJ/pulse, and energy density of 32 J/cm(2). Twenty eight additional rats served as a control group and their osteotomies were prepared with a drill 1.3 mm in diameter at 1000 rpm, with simultaneous saline irrigation. Two rats from the tested group and 2 from the control group were sacrificed on each day following surgery (1-14 days), and the tissue specimens were prepared for histologic evaluation. Immunohistochemical staining with anti-PDGF was performed after histologic examination. The difference between the PDGF staining intensities of the 2 treatment groups was analyzed using a multivariate logistic regression test. A significant rise in PDGF staining occurred in both groups 2-3 days following surgery. However, while high PDGF counts remained for the 2-week experimental period in the laser group, PDGF levels in the control group returned to baseline levels 8 days post surgery. The 2 groups (laser and control) were found to be different throughout the experiment, and the rat type was found to be a significant predictor (P  =  .000011). The present study demonstrated that Er:YAG laser irradiation seems to stimulate the secretion of PDGF in osteotomy sites in a rat model. It is possible that the high levels of PDGF are part of the mechanism that Er:YAG irradiation enhances and improves the healing of

  20. THF water hydrate crystallization: an experimental investigation

    NASA Astrophysics Data System (ADS)

    Devarakonda, Surya; Groysman, Alexander; Myerson, Allan S.

    1999-08-01

    Supersaturated solutions of THF-water hydrate system were experimentally studied before and during crystallization, to examine the system's behavior in the metastable zone and observe any anomalies suggesting cluster formation. Nucleation induction time measurements, with and without additives, were performed to screen potential growth inhibitors. Shifts in the onset points of crystallization for water and THF-water mixtures with additives were measured using differential scanning calorimetry (DSC). Aspartame was among one of the few successfully screened inhibitors. Preliminary on-line crystal size distribution (CSD) measurements were performed on this system to monitor the crystal size during crystallization. The CSD data was also used to compute the hydrate crystal growth rates, which were found to be in the order of 145 μm/h.

  1. Investigation of YAG:Ce Scintillating Fiber Properties Using Silicon Photomultipliers

    DTIC Science & Technology

    2011-03-01

    Maj Benjamin R. Kowash (Chairman) Date ____________________________________ ________________ Lt Col Michael R. Hawks...Member) Date ____________________________________ ________________ Abigail Bickley, PhD (Member) Date iv AFIT/GNE/ENP/11-M11 Abstract...Properties of Rare Earth Garnet Crystals ...........................................................36 Page vii 4. 2. Properties of the

  2. Clinical studies of Nd:YAG laser and Chinese herbal medicine in treatment of patients with tinea unguium

    NASA Astrophysics Data System (ADS)

    Dan, Ming-bing; Chen, Nanjin; Chao, Changyuan

    1993-03-01

    Forty-seven patients with tinea unguium and 110 tinea unguium, proven bacteriologically and pathologically, were treated with an Nd:YAG laser and Chinese herbal medicine, after which they were analyzed. All patients were adult men and women. The duration of illness varied from 1 to 10 years. The patients were treated with Nd:YAG laser wavelength 1.06 micrometers and the ending output power 500 w/cm2. The diseased nail was removed by laser scanning or cauterization, charring, gasification and coagulation layer by layer until the nail matrix was exposed, and then it was bandaged with a small amount of Chinese herbal medicine. The cure rate is 80.0%. The tinea unguium infection rate of pars super finialis is very high in cities, accounting for more than 80% of the cases among the population. It influences patients' lives and finger appearance. However, removal of tinea unguium with Nd:YAG laser cauterization and coagulation is simple, painless, and does not require disinfection. Also, the reoccurrence rate is low. Treatment of tinea unguium is intractable. Oral administration of griseofulvin and ketoconazole are not completely satisfactory and hardly persist for a long-term treatment course. Moreover, long-term administration of these drugs might produce serious side effects such as renal injuries, leukopenia, psychosis, etc. Thus, we conclude from this data that Nd:YAG laser and Chinese herbal medicine are an effective treatment for hypertrophic scarand kiloid and valuable for further investigations.

  3. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting

    PubMed Central

    Kim, Jin-Soo; Choi, Jung Yeol; Kwon, Ji-Won; Wee, Won Ryang; Han, Young Keun

    2018-01-01

    AIM To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG) laser posterior capsulotomy with vitreous strand cutting METHODS A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO) were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern). The best corrected visual acuity (BCVA), intraocular pressure (IOP), refractive error, endothelial cell count (ECC), anterior segment parameters, including anterior chamber depth (ACD) and anterior chamber angle (ACA) were measured before and 1mo after the laser posterior capsulotomy. RESULTS In both groups, the BCVA improved significantly (P<0.001 for the modified round pattern group, P=0.001 for the cruciate pattern group); the IOP and ECC did not significantly change. The ACD significantly decreased (P<0.001 for both) and the ACA significantly increased (P=0.001 for the modified round pattern group and P=0.034 for the cruciate group). The extent of changes in these parameters was not significantly different between the groups. CONCLUSION Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO. PMID:29487812

  4. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting.

    PubMed

    Kim, Jin-Soo; Choi, Jung Yeol; Kwon, Ji-Won; Wee, Won Ryang; Han, Young Keun

    2018-01-01

    To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG) laser posterior capsulotomy with vitreous strand cutting. A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO) were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern). The best corrected visual acuity (BCVA), intraocular pressure (IOP), refractive error, endothelial cell count (ECC), anterior segment parameters, including anterior chamber depth (ACD) and anterior chamber angle (ACA) were measured before and 1mo after the laser posterior capsulotomy. In both groups, the BCVA improved significantly ( P <0.001 for the modified round pattern group, P =0.001 for the cruciate pattern group); the IOP and ECC did not significantly change. The ACD significantly decreased ( P <0.001 for both) and the ACA significantly increased ( P =0.001 for the modified round pattern group and P =0.034 for the cruciate group). The extent of changes in these parameters was not significantly different between the groups. Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO.

  5. Resonantly diode-pumped continuous-wave and Q-switched Er:YAG laser at 1645 nm.

    PubMed

    Chang, N W H; Simakov, N; Hosken, D J; Munch, J; Ottaway, D J; Veitch, P J

    2010-06-21

    We describe an efficient Er:YAG laser that is resonantly pumped using continuous-wave (CW) laser diodes at 1470 nm. For CW lasing, it emits 6.1 W at 1645 nm with a slope efficiency of 36%, the highest efficiency reported for an Er:YAG laser that is pumped in this manner. In Q-switched operation, the laser produces diffraction-limited pulses with an average power of 2.5 W at 2 kHz PRF. To our knowledge this is the first Q-switched Er:YAG laser resonantly pumped by CW laser diodes.

  6. Growth, structural, spectral, optical, and thermal studies on amino acid based new NLO single crystal: L-phenylalanine-4-nitrophenol.

    PubMed

    Prakash, M; Lydia Caroline, M; Geetha, D

    2013-05-01

    A new organic nonlinear optical single crystal, L-phenylalanine-4-nitrophenol (LPAPN) belonging to the amino acid group has been successfully grown by slow evaporation technique. The lattice parameters of the grown crystal have been determined by X-ray diffraction studies. FT-IR spectrum was recorded to identify the presence of functional group and molecular structure was confirmed by NMR spectrum. Thermal strength of the grown crystal has been studied using TG-DTA analyses. The grown crystals were found to be transparent in the entire visible region. The existence of second harmonic generation signals was observed using Nd:YAG laser with fundamental wavelength of 1064 nm. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Studies on synthesis, growth, structural, thermal, linear and nonlinear optical properties of organic picolinium maleate single crystals.

    PubMed

    Pandi, P; Peramaiyan, G; Sudhahar, S; Chakkaravarthi, G; Mohan Kumar, R; Bhagavannarayana, G; Jayavel, R

    2012-12-01

    Picolinium maleate (PM), an organic material has been synthesised and single crystals were grown by slow evaporation technique. The structure of the grown crystal was elucidated by using single crystal X-ray diffraction analysis. PM crystal belongs to the monoclinic crystallographic system with space group P2(1)/c. The crystalline perfection of the grown crystals was analyzed by high-resolution X-ray diffraction rocking curve measurements. The presence of functional groups in PM was identified by FTIR and FT-NMR spectral analyses. Thermal behaviour and stability of picolinium maleate were studied by TGA/DTA analyses. UV-Vis spectral studies reveal that PM crystals are transparent in the wavelength region 327-1100 nm. The laser damage threshold value of PM crystal was found to be 4.3 GW/cm(2) using Nd:YAG laser. The Kurtz and Perry powder second harmonic generation technique confirms the nonlinear optical property of the grown crystal. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Eligibility criteria for Nd-YAG laser treatment of highly symptomatic vitreous floaters.

    PubMed

    Vandorselaer, T; Van De Velde, F; Tassignon, M J

    2001-01-01

    Ten eyes of nine patients were treated for very disturbing vitreous floaters with the technique of Nd-YAG laser vitreolysis. The Scanning Laser Ophthalmoscope (SLO) was used to objectivate the position, the size and the motility of the vitreous floaters with respect to the patient's visual axis, which can be precisely located with the SLO. With this technique it was possible to define more precisely some eligibility criteria for Nd-YAG laser treatment of vitreous floaters and to classify the vitreous floaters in ill-suspended and well-suspended floaters in the vitreous body, the well-suspended floaters responding better to treatment compared to the ill-suspended vitreous floaters. The treatment was performed using the Q-Switched Nd-YAG Laser type Nanolas 15S of Alcon.

  9. Impact of pulse duration on Ho:YAG laser lithotripsy: fragmentation and dusting performance.

    PubMed

    Bader, Markus J; Pongratz, Thomas; Khoder, Wael; Stief, Christian G; Herrmann, Thomas; Nagele, Udo; Sroka, Ronald

    2015-04-01

    In vitro investigations of Ho:YAG laser-induced stone fragmentation were performed to identify potential impacts of different pulse durations on stone fragmentation characteristics. A Ho:YAG laser system (Swiss LaserClast, EMS S.A., Nyon, Switzerland) with selectable long or short pulse mode was tested with regard to its fragmentation and laser hardware compatibility properties. The pulse duration is depending on the specific laser parameters. Fragmentation tests (hand-held, hands-free, single-pulse-induced crater) on artificial BEGO stones were performed under reproducible experimental conditions (fibre sizes: 365 and 200 µm; laser settings: 10 W through combinations of 0.5, 1, 2 J/pulse and 20, 10, 5 Hz, respectively). Differences in fragmentation rates between the two pulse duration regimes were detected with statistical significance for defined settings. Hand-held and motivated Ho:YAG laser-assisted fragmentation of BEGO stones showed no significant difference between short pulse mode and long pulse mode, neither in fragmentation rates nor in number of fragments and fragment sizes. Similarly, the results of the hands-free fragmentation tests (with and without anti-repulsion device) showed no statistical differences between long pulse and short pulse modes. The study showed that fragmentation rates for long and short pulse durations at identical power settings remain at a comparable level. Longer holmium laser pulse duration reduces stone pushback. Therefore, longer laser pulses may result in better clinical outcome of laser lithotripsy and more convenient handling during clinical use without compromising fragmentation effectiveness.

  10. Melasma treatment using an erbium:YAG laser: a clinical, immunohistochemical, and ultrastructural study.

    PubMed

    Attwa, Enayat; Khater, Mohamed; Assaf, Magda; Haleem, Manal Abdel

    2015-02-01

    Melasma is a common pigmentary disorder that remains resistant to available therapies. The aim of the present study was to evaluate the efficacy of erbium:YAG lasers in the treatment of refractory melasma and investigate the histopathological and ultrastructural changes between melasma skin and adjacent control skin before and after surgery. Fifteen Egyptian female patients with melasma unresponsive to previous therapy of bleaching creams and chemical peels were included in this study. Full-face skin resurfacing using an erbium:YAG laser was performed. Clinical parameters included physician and patient assessment, and melasma area and severity index score were done. Adverse effects after laser resurfacing were recorded. Biopsies of lesions and adjacent healthy skin were stained using hematoxylin-eosin, immunohistochemically marked for Melan-A, and evaluated by electron microscopy. The amount of melanin, staining intensity, and number of epidermal melanocytes are increased in melasma lesions as compared to normal skin. Electron microscopic analysis revealed an increased number of mature melanosomes in keratinocytes and melanocytes, with more marked cytoplasmic organelles in melasma skin than in biopsy specimens from normal skin, suggesting increased cell activity. After surgery, the number of melanocytes and concentration of melanin decreased in melasma skin, and the mean melasma area and severity index score decreased dramatically. Erbium:YAG laser resurfacing effectively improves melasma; however, the almost universal appearance of transient postinflammatory hyperpigmentation necessitates prompt and persistent intervention. © 2014 The International Society of Dermatology.

  11. Er:YAG laser-assisted hair transplantation in cicatricial alopecia.

    PubMed

    Podda, M; Spieth, K; Kaufmann, R

    2000-11-01

    Autologous hair transplantation and its combination with flap or reduction procedures is a common surgical approach to cover defects in cicatricial alopecias. Due to the poor recipient conditions present in scar tissue, it is crucial to minimize the trauma exerted on implantation holes in order to achieve good transplantation results. We sought to evaluate the "cold"-ablative properties of the Er:YAG laser for the generation of recipient holes in cicatricial alopecia. Patients with cicatricial alopecia of diverse etiology were treated with Er:YAG laser-assisted hair transplantation. Mini- or micrografts were inserted into recipient holes ablated with a pulse energy of 900-1200 mJ and a spot size of 1.0-1.6 mm. A fluence of 80-120 J/cm2 and 8-12 pulses gave an almost ideal combination of minimal thermal damage and tissue ablation down to the subcutis. With an apparent mini- and micrograft survival of 95% we achieved good cosmetic results after two to five transplant sessions in all patients. The Er:YAG laser is a novel effective tool to ablate recipient holes for autologous hair transplantation in cicatricial alopecia.

  12. Bactericidal effect of Nd:YAG laser irradiation in endodontics

    NASA Astrophysics Data System (ADS)

    Aun, Carlos E.; Barberini, Alexandre F.; Camargo, Selma C. C.; Silva Kfouri, Luciana; Lorenzetti Simionato, Maria R.

    1999-05-01

    The success of endodontic therapy is based on the elimination of bacterial colonization from the endodontic system and periapical tissues. Recent studies have been showing the bactericidal effect of laser in root canal treatment. The propose of the study is to evaluate the effect of Nd:YAG laser irradiation in contaminated root canal treatment. The propose of the study is to evaluate the effect of Nd:YAG laser irradiation in contaminated root canals from upper central incisor. For the experiment 12 teeth were selected, respect at the apical third, sterilized, and 10 μm Streptococcus sanguis liquid culture were inoculated in the root canals. The laser test groups were irradiated with Nd:YAG laser at standard setting of 15Hz, 100mj and 1,5 W for 10, 20 and 30 seconds each in slow helicoidal movements from the apex to the top using a 300 micrometers fiber. After the procedure the specimens were placed in Tryptic Soy Agar, the number of colony forming units was evaluated. The experiment showed a significant reduction on viability of Streptococcus sanguis at the respective time of 20 and 30 seconds.

  13. Composite Yb:YAG/SiC-prism thin disk laser.

    PubMed

    Newburgh, G A; Michael, A; Dubinskii, M

    2010-08-02

    We report the first demonstration of a Yb:YAG thin disk laser wherein the gain medium is intracavity face-cooled through bonding to an optical quality SiC prism. Due to the particular design of the composite bonded Yb:YAG/SiC-prism gain element, the laser beam impinges on all refractive index interfaces inside the laser cavity at Brewster's angles. The laser beam undergoes total internal reflection (TIR) at the bottom of the Yb(10%):YAG thin disk layer in a V-bounce cavity configuration. Through the use of TIR and Brewster's angles, no optical coatings, either anti-reflective (AR) or highly reflective (HR), are required inside the laser cavity. In this first demonstration, the 936.5-nm diode pumped laser performed with approximately 38% slope efficiency at 12 W of quasi-CW (Q-CW) output power at 1030 nm with a beam quality measured at M(2) = 1.5. This demonstration opens up a viable path toward novel thin disk laser designs with efficient double-sided room-temperature heatsinking via materials with the thermal conductivity of copper on both sides of the disk.

  14. Effect of pulsed Nd:YAG on dentin morphological changes

    NASA Astrophysics Data System (ADS)

    Moriyama, Eduardo H.; Zangaro, Renato A.; Villaverde, Antonio G. J. B.; Watanabe-Sei, Ii; Munin, Egberto; Sasaki, Luis H.; Otsuka, Daniel K.; Lobo, Paulo D. d. C.; Pacheco, Marcos T. T.; Junior, Durval R.

    2002-06-01

    Infrared lasers have been used for several clinical applications in dentistry, including laser ablation, oral surgeries and dentin hypersensitivity treatment. Despite of dentin low absorption coefficient in the near infrared spectrum, Nd:YAG laser radiation ((lambda) = 1064 nm) is able to melt the human dentin surface resulting in dentin tubules closure that can suppress the symptoms of dentin hypersensitivity pathology. Objectives: This study aims to analyze, through SEM technique, the morphological changes in dentin surface after Nd:YAG laser irradiation using different parameters in energy distribution. Materials and Methods: In this study sixteen human dentin samples were submitted to Nd:YAG laser radiation using a total energy of 900mJ distributed in one, two, three or six laser pulses with energy for each pulse of 900, 450, 300 or 150 mJ respectively. All the samples were irradiated with laser pulse width of 90ms, pulse intervals of 300 ms and spot size area of 0,005 cm2. Results: SEM analysis suggests that differences in energy distribution results in morphological differences even though the same energy is used for all the samples.

  15. Comparison of tensile bond strengths of four one-bottle self-etching adhesive systems with Er:YAG laser-irradiated dentin.

    PubMed

    Jiang, Qianzhou; Chen, Minle; Ding, Jiangfeng

    2013-12-01

    This study aimed to investigate the interaction of current one-bottle self-etching adhesives and Er:YAG laser with dentin using a tensile bond strength (TBS) test and scanning electron microscopy (SEM) in vitro. Two hundred and thirteen dentin discs were randomly distributed to the Control Group using bur cutting and to the Laser Group using an Er:YAG laser (200 mJ, VSP, 20 Hz). The following adhesives were investigated: one two-step total-etch adhesive [Prime & Bond NT (Dentsply)] and four one-step self-etch adhesives [G-Bond plus (GC), XENO V (Dentsply), iBond Self Etch (Heraeus) and Adper Easy One (3 M ESPE)]. Samples were restored with composite resin, and after 24-hour storage in distilled water, subjected to the TBS test. For morphological analysis, 12 dentin specimens were prepared for SEM. No significant differences were found between the control group and laser group (p = 0.899); dentin subjected to Prime & Bond NT, XENOV and Adper Easy One produced higher TBS. In conclusion, this study indicates that Er:YAG laser-prepared dentin can perform as well as bur on TBS, and some of the one-step one-bottle adhesives are comparable to the total-etch adhesives in TBS on dentin.

  16. Synthesis, crystal growth, structural, thermal and optical properties of naphthalene picrate an organic NLO material.

    PubMed

    Chandramohan, A; Bharathikannan, R; Kandavelu, V; Chandrasekaran, J; Kandhaswamy, M A

    2008-12-01

    Crystalline substance of naphthalene picrate (NP) was synthesized and single crystals were grown using slow evaporation solution growth technique. The solubility of the naphthalene picrate complex was estimated using different solvents such as chloroform and benzene. The material was characterized by elemental analysis, powder X-ray diffraction (XRD), nuclear magnetic resonance (NMR) and fourier transform-infrared (FT-IR) techniques. The electronic absorption was studied through UV-vis spectrophotometer. Thermal behavior and stability of the crystal were studied using thermogravimetric (TG) and differential thermal analysis (DTA) techniques. The second harmonic generation (SHG) of the material was confirmed using Nd:YAG laser.

  17. Synthesis, crystal growth and studies on non-linear optical property of new chalcones

    NASA Astrophysics Data System (ADS)

    Sarojini, B. K.; Narayana, B.; Ashalatha, B. V.; Indira, J.; Lobo, K. G.

    2006-09-01

    The synthesis, crystal growth and non-linear optical (NLO) property of new chalcone derivatives are reported. 4-Propyloxy and 4-butoxy benzaldehydes were made to under go Claisen-Schmidt condensation with 4-methoxy, 4-nitro and 4-phenoxy acetophenones to form corresponding chalcones. The newly synthesized compounds were characterized by analytical and spectral data. The Second harmonic generation (SHG) efficiency of these compounds was measured by powder technique using Nd:YAG laser. Among tested compounds three chalcones showed NLO property. The chalcone 1-(4-methoxyphenyl)-3-(4-propyloxy phenyl)-2-propen-1-one exhibited SHG conversion efficiency 2.7 times that of urea. The bulk crystal of 1-(4-methoxyphenyl)-3-(4-butoxyphenyl)-2-propen-1-one (crystal size 65×28×15 mm 3) was grown by slow-evaporation technique from acetone. Microhardness of the crystal was tested by Vicker's microhardness method.

  18. Effect of Nd:YAG laser capsulotomy on refraction in multifocal apodized diffractive pseudophakia.

    PubMed

    Vrijman, Violette; van der Linden, Jan Willem; Nieuwendaal, Carla P; van der Meulen, Ivanka J E; Mourits, Maarten P; Lapid-Gortzak, Ruth

    2012-08-01

    To evaluate the effect on refraction of neodymium:YAG (Nd:YAG) laser posterior capsulotomy for posterior capsule opacification (PCO), and to evaluate the correlation between automated and subjective refraction in multifocal apodized diffractive pseudophakia. A retrospective study of 75 pseudophakic eyes (50 patients) with multifocal apodized diffractive pseudophakia, treated for PCO with Nd:YAG laser posterior capsulotomy, was performed. Pre- and postintervention values of refractive and visual parameters were compared. The outcomes of autorefraction and subjective refraction were also compared. Uncorrected and corrected distance visual acuity improved significantly after Nd:YAG capsulotomy (P<.001). No significant changes were noted in defocus equivalent, astigmatic power vectors J(0) and J(45), and overall blurring strength in subjective refraction and autorefraction. Spherical equivalent changed significantly in autorefraction (P=.008), but not in subjective refraction. Autorefraction and subjective refraction were highly correlated in spherical equivalent, defocus equivalent, and blurring strength (r(2)>0.59). In approximately 7% of eyes, a change of more than 0.50 diopters in spherical equivalent in subjective refraction occurred. In most cases, Nd:YAG laser capsulotomy in patients with multifocal pseudophakia did not result in a change in refraction. However, 7% of eyes experienced a significant change in subjective refraction. Autorefraction correlated well with subjective refraction in apodized diffractive multifocal IOLs. Copyright 2012, SLACK Incorporated.

  19. Effects of Er:YAG laser irradiation on human cartilage

    NASA Astrophysics Data System (ADS)

    Glinkowski, Wojciech; Brzozowska, Malgorzata; Ciszek, Bogdan; Rowinski, Jan; Strek, Wieslaw

    1996-03-01

    Irradiation of the hyaline or fibrous cartilage excised from the body of a human cadaver with Er:YAG laser beam, single pulse with a dose of 1 J, produces a crater with a depth of approximately 500 micrometers and a diameter varying from 5 to 300 micrometers. Histological examination has revealed that the laser-made craters were surrounded by a thin rim (2-10 micrometer) of charred and coagulated tissue. No damage was observed in the cartilage surrounding the rim. The presence of sharp demarcation between the tissue areas ablated by laser energy and the undamaged areas argues for the potential usefulness of the Er:YAG laser in surgery of cartilages.

  20. Further characterization of photothermal breakdown products of uric acid stones following holmium:YAG laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Glickman, Randolph D.; Weintraub, Susan T.; Kumar, Neeru; Corbin, Nicole S.; Lesani, Omid; Teichman, Joel M. H.

    2000-06-01

    Previously we found that Ho:YAG laser (2120 nm) lithotripsy of uric acid stones produced cyanide, a known thermal breakdown product of uric acid. We now report that alloxan, another thermal breakdown product, is also likely produced. Uric acid stones (approximately 98% pure) of human origin were placed in distilled water and subjected to one of the following experimental treatments: unexposed control, exposed to Ho:YAG laser, Nd:YAG laser, or mechanically crushed. Samples were then processed for HPLC analysis with UV detection. Peaks were identified by comparison to authentic standards. All samples contained uric acid, with retention time (RT) about 6 min. All of the laser-exposed samples contained a peak that eluted at 2.5 min, identical to the RT of authentic alloxan. Ho:YAG laser irradiation, however, produced a larger presumed alloxan peak than did the Nd:YAG laser. The peak at 2.5 min, as well as unidentified later-eluting peaks, were present in the laser-exposed, but not the unexposed or mechanically crushed, samples. These results confirm the thermal nature of lithotripsy performed with long-pulse IR lasers.

  1. Forskolin and rutin prevent intraocular pressure spikes after Nd:YAG laser iridotomy.

    PubMed

    Nebbioso, M; Belcaro, G; Librando, A; Rusciano, D; Steigerwalt, R D; Pescosolido, N

    2012-12-01

    the purpose of this research was to evaluate whether an oral treatment with an association of forskolin and rutin can blunt the intraocular pressure (IOP) spikes and avoid the damage that may occur after laser iridotomy. Ten patients underwent bilateral Neodymium:YAG (Nd:YAG) laser iridotomy (Visulas YAG III Laser, Zeiss), for the prevention of primary closed-angle glaucoma. IOP was measured in subjects before and after 7 days of pretreatment with placebo or forskolin and rutin by Goldman applanation tonometry. The IOP was measured before surgery and after surgery at 30-60-120 minutes, and 4-7 days. Analysis of variance indicated a significant increase of the postoperative values in patients receiving treatment with placebo (p < 0.001), but not in those who received treatment with the forskolin and rutin association. T test analysis confirmed that IOP still remained significantly elevated 7 days after laser intervention in placebo treated patients, whereas it stayed within normal values in forskolin/rutin treated patients. Forskolin and rutin can blunt the increase of IOP that occurs after Nd-YAG laser iridotomy. This can avoid serious risk to the optic nerve of the patients under laser treatment for iridotomy.

  2. Cutting and coagulation during intraoral soft tissue surgery using Er: YAG laser.

    PubMed

    Onisor, I; Pecie, R; Chaskelis, I; Krejci, I

    2013-06-01

    To find the optimal techniques and parameters that enables Er:YAG laser to be used successfully for small intraoral soft tissue interventions, in respect to its cutting and coagulation abilities. In vitro pre-tests: 4 different Er:YAG laser units and one CO2 unit as the control were used for incision and coagulation on porcine lower jaws and optimal parameters were established for each type of intervention and each laser unit: energy, frequency, type, pulse duration and distance. 3 different types of intervention using Er:YAG units are presented: crown lengthening, gingivoplasty and maxillary labial frenectomy with parameters found in the in vitro pre-tests. The results showed a great decrease of the EMG activity of masseter and anterior temporalis muscles. Moreover, the height and width of the chewing cycles in the frontal plane increased after therapy. Er:YAG is able to provide good cutting and coagulation effects on soft tissues. Specific parameters have to be defined for each laser unit in order to obtain the desired effect. Reduced or absent water spray, defocused light beam, local anaesthesia and the most effective use of long pulses are methods to obtain optimal coagulation and bleeding control.

  3. Analysis of Shear Bond Strength and Morphology of Er:YAG Laser-Recycled Ceramic Orthodontic Brackets

    PubMed Central

    Han, Ruo-qiao; Ji, Ling-fei; Ling, Chen

    2016-01-01

    Objective. The aim of this study was to compare the recycling of deboned ceramic brackets via an Er:YAG laser or via the traditional chairside processing methods of flaming and sandblasting; shear bond strength and morphological changes were evaluated in recycled brackets versus new brackets. Materials and Methods. 3M Clarity Self-Ligating Ceramic Brackets with a microcrystalline base were divided into groups subjected to flaming, sandblasting, or exposure to an Er:YAG laser. New ceramic brackets served as a control group. Shear bond strengths were determined with an Electroforce test machine and tested for statistical significance through analysis of variance. Morphological examinations of the recycled ceramic bracket bases were conducted with scanning electron microscopy and confocal laser scanning microscopy. Residue on the bracket base was analyzed with Raman spectroscopy. Results. Faded, dark adhesive was left on recycled bracket bases processed via flaming. Adhesive was thoroughly removed by both sandblasting and exposure to an Er:YAG laser. Compared with new brackets, shear bond strength was lower after sandblasting (p < 0.05), but not after exposure to an Er:YAG laser. The Er:YAG laser caused no damage to the bracket. Conclusion. Er:YAG lasers effectively remove adhesive from the bases of ceramic brackets without damaging them; thus, this method may be preferred over other recycling methods. PMID:27047964

  4. Development of cryogenic Yb:YAG ceramics amplifier for over 100 J DPSSL

    NASA Astrophysics Data System (ADS)

    Sekine, T.; Takeuchi, Y.; Kurita, T.; Hatano, Y.; Muramatsu, Y.; Mizuta, Y.; Kabeya, Y.; Tamaoki, Y.; Kato, Y.

    2017-02-01

    A high gain cryogenic Yb:YAG ceramics laser amplifier for a high energy laser amplification system has been developed. The laser system consists of a fiber oscillator and two stage LD pumped cryogenic Yb:YAG ceramic amplifiers. The preamplifier stage has a 5-pass laser amplifier head and the main amplifier stage has a 2-pass laser amplifier head, respectively. The preamplifier obtained an average stored energy density of 0.836 J/cc and small-signal gain (SSG) of 60 with 33 J of stored energy. Then about 1 μJ of input energy from the oscillator was amplified to 3.6 J. The main amplifier head had four pumping LD modules which irradiated the Yb:YAG ceramics directly. This original angular pumping scheme ideally increases irradiation intensity and homogenizes irradiation pattern on the Yb:YAG ceramics due to superposition effect of all of the LD modules. A maximum peak power of over 100 kW was generated by one LD module. When the output energy of the LD modules was 450 J, a 20 of SSG at single pass was obtained. Stored energy density was evaluated to 0.429 J/cc when 148 J energy was stored in 346 cc of Yb:YAG ceramics. As a result, a 55-J output energy with 10 ns pulse duration was demonstrated at a pumping energy of 450 J. The optical-tooptical conversion efficiency which includes transmissivity of the LD modules was 12 %. The extraction efficiency was estimated to 37%.

  5. Experimental study using ER-YAG laser in discs: changes in glycosaminoglycan content and synthesis in discs

    NASA Astrophysics Data System (ADS)

    Maehara, Kazuyuki; Nakai, Sadaaki; Naga, Kumi; Nishimoto, Seiji

    2004-09-01

    Changes in discs after Er-Yag laser irradiation are scarcely reported. We made an experimental study using white rabbits and Er-Yag laser. Under general anesthesia, Er-Yag laser was irradiated into lumbar discs. Three or 8 weeks after irradiation, rabbits were sacrificed, and these discs were extracted. The quantitative analysis of the glycosaminoglycan content in the annulus fibrosus, and the incorporation of 35S-sulfate in chondroitin 4 sulfate were measured. The results showed, the increased incorporation of 35S-sulfate in chondroitin 4 sulfate and chondroitin 6 sulfates in groups of laser irradiation may indicate Er-Yag laser irradiation in nucleus pulposus, accelerated glycosaminoglycan production, in the annulus fibrosus. But no difference of unsaturated isomers of chondroitin 4 sulfate, and chondroitin 6 sulfate, and no difference of saturated isomer of keratan sulfate indicate, the influence of Er-Yag laser irradiation was not so high, as to bring the quantitative changes of matrix of annulus fibrosus in term of 8 weeks.

  6. Comparison of holmium:YAG and thulium fiber laser lithotripsy: ablation thresholds, ablation rates, and retropulsion effects.

    PubMed

    Blackmon, Richard L; Irby, Pierce B; Fried, Nathaniel M

    2011-07-01

    The holmium:YAG (Ho:YAG) laser lithotriptor is capable of operating at high pulse energies, but efficient operation is limited to low pulse rates (∼10 Hz) during lithotripsy. On the contrary, the thulium fiber laser (TFL) is limited to low pulse energies, but can operate efficiently at high pulse rates (up to 1000 Hz). This study compares stone ablation threshold, ablation rate, and retropulsion for the two different Ho:YAG and TFL operation modes. The TFL (λ = 1908 nm) was operated with pulse energies of 5 to 35 mJ, 500-μs pulse duration, and pulse rates of 10 to 400 Hz. The Ho:YAG laser (λ = 2120 nm) was operated with pulse energies of 30 to 550 mJ, 350-μs pulse duration, and a pulse rate of 10 Hz. Laser energy was delivered through 200- and 270-μm-core optical fibers in contact mode with human calcium oxalate monohydrate (COM) stones for ablation studies and plaster-of-Paris stone phantoms for retropulsion studies. The COM stone ablation threshold for Ho:YAG and TFL measured 82.6 and 20.8 J∕cm(2), respectively. Stone retropulsion with the Ho:YAG laser linearly increased with pulse energy. Retropulsion with TFL was minimal at pulse rates less than 150 Hz, then rapidly increased at higher pulse rates. For minimal stone retropulsion, Ho:YAG operation at pulse energies less than 175 mJ at 10 Hz and TFL operation at 35 mJ at 100 Hz is recommended, with both lasers producing comparable ablation rates. Further development of a TFL operating with both high pulse energies of 100 to 200 mJ and high pulse rates of 100 to 150 Hz may also provide an alternative to the Ho:YAG laser for higher ablation rates, when retropulsion is not a primary concern.

  7. Double Stokes-Mueller polarimetry in KTP (Potassium Titanyl Phosphate) crystal

    NASA Astrophysics Data System (ADS)

    Shaji, Chitra; S B, Sruthil Lal; Sharan, Alok

    2017-04-01

    Ultra-structural properties of material are being probed by Double Stokes-Mueller polarimetry (DSMP) technique. It makes use of higher dimensions of Stokes vector (9 X 1) and Mueller matrix (4 X9) to characterize the nonlinear optical properties of a material. Second harmonic generation (SHG) at 532nm using 1064nm as fundamental cw beam from Nd: YAG laser in type II phase matched KTP (Potassium Titanyl Phosphate) crystal is studied using DSMP. The experimental measurements for determining double Mueller matrix are carried out in the ``Polarization In Polarization Out'' (PIPO) arrangement. Nine input polarization states are incident on the sample and the linear Stokes vector of the emerging light from the sample is measured. The KTP crystal is oriented such that the SHG signal efficiency at the incident horizontal and vertical polarizations is high as compared to diagonal polarization states. The susceptibility tensor components and the phase difference between them at this orientation are determined from the double Mueller matrix elements. These determined values give information regarding the crystal axis orientations. To our knowledge, this is the first report of the use of DSMP technique to determine the crystal orientations of a biaxial crystal.

  8. 36 W Q-switched Ho:YAG laser at 2097 nm pumped by a Tm fiber laser: evaluation of different Ho3+ doping concentrations

    NASA Astrophysics Data System (ADS)

    Antipov, O. L.; Eranov, I. D.; Kositsyn, R. I.

    2017-01-01

    A laser oscillator based on Ho:YAG crystal pumped by a Tm fiber laser with an acousto-optical Q-switch was optimized for maximum output power and pulse-to-pulse stability. Stable operation at 2097 nm in Q-switched mode is demonstrated, with pulse repetition rates from 10 to 30 kHz, and output power of 36 W (at 55 W of pump power at 1908 nm) in the good quality beam. The influence of Ho ion up-conversion and thermal lensing on the oscillation efficiency is discussed.

  9. Structural changes in the irradiated dentin with Nd:YAG and Er:YAG lasers for cervical hypersensitivity treatment and their influence on the microtensile resistance in resin-dentin interface

    NASA Astrophysics Data System (ADS)

    Mota, Cláudia C. B. O.; Sena, Tatiane V. N. S.; Castro, Roseane F.; Araújo, Ana C. S.; Gomes, Anderson S. L.

    2016-02-01

    This study aimed to evaluate, in vitro, the structural changes in dentin surfaces irradiated with Er:YAG (2940 nm, 90 mJ, 2 Hz, 300 μs, spot diameter 0.9 mm, 60 s/cm2, using the handpiece at 6 cm of distance to surface) and Nd:YAG (1064 nm, 1 W, 10 Hz, 300 μs, optical fiber diameter 300 μm, 60 s/cm2, using the handpiece at 2 mm of distance to surface) lasers to the treatment of cervical hypersensitivity and the respective bond strength compromising of resin composite restorations over these surfaces. 45 bovine teeth were selected, and removed the enamel portion of the buccal surface for laser irradiation and restorative procedure. Samples were divided into three groups: G1: control, only fluoride therapy; G2: irradiated with Er:YAG laser; G3: irradiated with Nd:YAG laser. Samples were submitted to optical coherence tomography analysis and subsequently they were restored with resin composite and sectioned into sticks for microtensile tests of achievement. ANOVA analysis of variance for the maximum force (N) and strength (MPa), with a significance level of 5% was performed. It was observed that G3 presented lower performance of maximum force (38,8 +/- 11,3 N) and resistance (26,0 +/- 9,3 MPa), and the G2 presented better results (51,0 +/- 13,5 N and 36,5 +/- 10,1 MPa), but still lower than those one obtained for G1 (56,0 +/- 12,3 N and 43,5 +/- 8,6 MPa). Although both lasers are effective in the cervical hypersensitivity treatment, when the aesthetic factor is the priority, the use of Er:YAG is preferable.

  10. Spherical quartz crystals investigated with synchrotron radiation

    DOE PAGES

    Pereira, N. R.; Macrander, A. T.; Hill, K. W.; ...

    2015-10-27

    The quality of x-ray spectra and images obtained from plasmas with spherically bent crystals depends in part on the crystal's x-ray diffraction across the entire crystal surface. We employ the energy selectivity and high intensity of synchrotron radiation to examine typical spherical crystals from alpha-quartz for their diffraction quality, in a perpendicular geometry that is particularly convenient to examine sagittal focusing. The crystal's local diffraction is not ideal: the most noticeable problems come from isolated regions that so far have failed to correlate with visible imperfections. In conclusion, excluding diffraction from such problem spots has little effect on the focusmore » beyond a decrease in background.« less

  11. Direct inkjet printing of miniaturized luminescent YAG:Er3+ from sol-gel precursor

    NASA Astrophysics Data System (ADS)

    Hong, Yuzhe; Chen, Zhaoxi; Trofimov, Artem A.; Lei, Jincheng; Chen, Jie; Yuan, Lei; Zhu, Wenge; Xiao, Hai; Xu, Dong; Jacobsohn, Luiz G.; Kornev, Konstantin G.; Bordia, Rajendra K.; Peng, Fei

    2017-06-01

    This work focuses on demonstrating the fabrication of miniaturized scintillators based on rare earth activated YAG ceramics using the direct inkjet printing method. Erbium was chosen as the activator, and YAG sol-gel precursor inks were prepared under precise hydrolysis and polycondensation reactions. The precursors showed excellent control over rheology and surface tension, resulting in good printability. One of the most important challenges of inkjet printing of lines is the stability of lines. Line stability during printing is highly dependent on the printing frequency, drop spacing and substrate temperature. When a line was printed drop by drop, bulges were always observed during printing at 25 °C. This instability was significantly suppressed when the substrates were slightly heated. Adding polyvinylpyrrolidone to the precursor helped eliminate pores and cracks during firing. Crack-free YAG lines with ∼200 nm thickness were obtained after firing. The photoluminescence of YAG:Er heat-treated at 1200 °C for 1 h was optimized for an Er concentration of 2 wt%. X-ray induced radioluminescence was dominated by emission lines at 398 and 567 nm.

  12. Multi-Billion Shot, High-Fluence Exposure of Cr(4+): YAG Passive Q-Switch

    NASA Technical Reports Server (NTRS)

    Stephen, Mark A.; Dallas, Joseph L.; Afzal, Robert S.

    1997-01-01

    NASA's Goddard Space Flight Center is developing the Geoscience Laser Altimeter System (GLAS) employing a diode pumped, Q-Switched, ND:YAG laser operating at 40 Hz repetition rate. To meet the five-year mission lifetime goal, a single transmitter would accumulate over 6.3 billion shots. Cr(4+):YAG is a promising candidate material for passively Q-switching the laser. Historically, the performance of saturable absorbers has degraded over long-duration usage. To measure the multi-billion shot performance of Cr(4+):YAG, a passively Q-switched GLAS-like oscillator was tested at an accelerated repetition rate of 500 Hz. The intracavity fluence was calculated to be approximately 2.5 J/cm(exp 2). The laser was monitored autonomously for 165 days. There was no evidence of change in the material optical properties during the 7.2 billion shot test.. All observed changes in laser operation could be attributed to pump laser diode aging. This is the first demonstration of multi-billion shot exposure testing of Cr(4+):YAG in this pulse energy regime

  13. Transmyocardial revascularization on canine with Ho:YAG laser - an experimental study

    NASA Astrophysics Data System (ADS)

    Bao, Xiaoqing; Zhu, Jing; Zhang, Hui-Guo

    2005-07-01

    Background and Objective: To evaluate the efficiency of transmyocardial revascularization with Ho:YAG laser and find out adequate physical parameters of the laser. Materials and Methods: 10 dogs were studied. All the samples were divided into two groups: the laser group (5 dogs) and the control group (5 dogs). Acute myocardial ischemia was induced in all the samples, and transmyocardial laser revascularization (TMLR) was only done in the laser group. We compared the difference of improvement in myocardial perfusion between the two groups with single photon emission computed tomograph (SPECT) and observed the patency of the laser channels and heat injures in the tissue adjacent to the channels with light- and electro-scope. Results: After 4 weeks, the recovery of myocardial perfusion was significantly faster in the laser group than in the control group through SPECT (P<0.05). Most of the laser channels drilled with Ho:YAG laser were filled with fibrin. There were amount of microvessels and erythrocytes inside and around the channels. Only slight heat injures were seen in the tissue adjacent to the channels. Only 20-30 watts were needed in TMLR. Conclusions: Transmyocardial revascularization with Ho:YAG laser limits infarct expansion and reduces myocardial ischemia efficiently. TMLR with Ho:YAG laser can become a new technique to treat ischemic heart disease.

  14. Histologic comparison of the CO2 laser and Nd:YAG with and without water/air surface cooling on tooth root structure

    NASA Astrophysics Data System (ADS)

    Cobb, Charles M.; Spencer, Paulette; McCollum, Mark H.

    1995-05-01

    Specimens consisted of 18 extracted single rooted teeth unaffected by periodontal disease. After debriding roots, specimens were randomly divided into 4 treatment groups and subjected to a single pass, at varying energy densities, of a CO2, Nd:YAG, and Nd:YAG with air/water surface cooling (Nd:YAG-C). The rate of exposure was controlled at 4 mm/sec. Approximate energy densities were: CO2, 138, 206, 275, and 344 J/cm2; Nd:YAG, 114, 171, 229, and 286 J/cm2; Nd:YAG-C, 286, 343, 514, and 571 J/cm2. The CO2 laser was used both in continuous and pulsed beam modes (20 Hz, 0.01 sec pulse length and 0.8 mm dia spot size) whereas the Nd:YAG and Nd:YAG-C were preset at 50 Hz, 0.08 sec pulse length and 0.6 mm dia spot size. Specimen examination by SEM revealed, for all lasers, a direct correlation between increasing energy densities and depth of tissue ablation and width of tissue damage. However, to achieve the same relative dept of tissue ablation, the Nd:YAG-C required higher energy densities than either the CO2 or Nd:YAG lasers. The Nd:YAG-C generated a cavitation with sharply defined margins. Furthermore, regardless of energy density, and in contrast with other laser types, areas treated with the Nd:YAG-C did not exhibit collateral zones of heat damaged surface tissue.

  15. Study of thin film production of ceramic ZrO2 on silicon wafer using second harmonic Nd-Yag laser with pulsed laser deposition technique

    NASA Astrophysics Data System (ADS)

    Suliyanti, Maria M.; Hidayah, Affi Nur; Kurniawan, K. H.

    2012-06-01

    Study about thin film production using technique pulsed laser deposition have been done. The Pulsed Laser Deposition (PLD) method has been used for growing thin film of ZrO2 on silicon wafer substrate (111 single crystal, thickness 400μm and diameter 7.5 cm). The target made from Zirconia oxide powder mixing with PVA and press using pressure 100kgN. The laser beam was focused by a lens (f = 100mm) through a quartz window onto the sample surface and the substrate was placed in parallel line with target. The distance between the target and the substrate is about 1 cm. The early results of this synthesis using 75 mJ Nd-YAG second harmonic laser pulse (532 nm Nd-YAG) and low pressure chamber surrounding gas 5 Torr. The irradiation of laser take around 6000 shoots or 10 minutes using frequencies laser 10 Hz. The micro thickness of film can be produced on silicon wafer using this technique. The results of ZrO2 thin film on substrate about 26.92%.

  16. Latest MIG, TIG arc-YAG laser hybrid welding systems for various welding products

    NASA Astrophysics Data System (ADS)

    Ishide, Takashi; Tsubota, Shuho; Watanabe, Masao

    2003-03-01

    Laser welding is capable of high-efficiency low-strain welding, and so its applications are started to various products. We have also put the high-power YAG laser of up to 10 kW to practical welding use for various products. On the other hand the weakest point of this laser welding is considered to be strict in the welding gap aiming allowance. In order to solve this problem, we have developed hybrid welding of TIG, MIG arc and YAG laser, taking the most advantages of both the laser and arc welding. Since the electrode is coaxial to the optical axis of the YAG laser in this process, it can be applied to welding of various objects. In the coaxial MIG, TIG-YAG welding, in order to make irradiation positions of the YAG laser beams having been guided in a wire or an electrode focused to the same position, the beam transmitted in fibers is separated to form a space between the separated beams, in which the laser is guided. With this method the beam-irradiating area can be brought near or to the arc-generating point. This enables welding of all directions even for the member of a three-dimensional shape. This time we carried out welding for various materials and have made their welding of up to 1 mm or more in welding groove gap possible. We have realized high-speed 1-pass butt welding of 4m/min in welding speed with the laser power of 3 kW for an aluminum alloy plate of approximately 4 mm thick. For a mild steel plate also we have realized butt welding of 1m/min with 5 kW for 6 mm thick. Further, in welding of stainless steel we have shown its welding possibility, by stabilizing the arc with the YAG laser in the welding atmosphere of pure argon, and shown that this welding is effective in high-efficiency welding of various materials. Here we will report the fundamental welding performances and applications to various objects for the coaxial MIG, TIG-YAG welding we have developed.

  17. Treatment of actinic cheilitis with the Er:YAG laser.

    PubMed

    Armenores, Paul; James, Craig L; Walker, Patrick C; Huilgol, Shyamala C

    2010-10-01

    Actinic cheilitis is a common condition with the potential to develop into squamous cell carcinoma. Current treatments have varying cure rates and complications. The role of the erbium:yttrium-aluminum-garnet (Er:YAG) laser in the treatment of actinic cheilitis has not been widely published, despite offering theoretical advantages over current treatment modalities. To evaluate the outcome of a series of patients treated with the Er:YAG laser for actinic cheilitis. This was a retrospective, interventional, nonrandomized, sequential case series set in a tertiary referral, dermatologic surgery unit. Ninety-nine consecutive patients with actinic cheilitis treated with the Er:YAG laser between January 2001 and June 2008 underwent a case note review, of which 77 went on to a structured telephone interview. The main outcome measures were a subjective improvement in lip symptoms related to actinic cheilitis and objective improvement in the lips at routine follow-up. Mean time to interview follow-up was 65.7 months. Of those interviewed, 92.2% believed there had been an improvement in the cosmetic appearance of their lips; one hundred percent believed the function of their lips had improved or remained unchanged; and 84.8% remained completely disease free at the time of follow-up. The majority of patients (93.5%) were satisfied with the laser treatment. Scarring as a direct result of the laser occurred in 5.1% of patients. Retrospective nature of data collection; inability to interview all patients who underwent treatment. The Er:YAG laser is a successful modality for the treatment of actinic cheilitis with good functional and cosmetic results and only a small risk of long-term scarring. It should be considered as a first-line treatment for the disease. Copyright © 2009 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Generation of Ince-Gaussian beams in highly efficient, nanosecond Cr, Nd:YAG microchip lasers

    NASA Astrophysics Data System (ADS)

    Dong, J.; Ma, J.; Ren, Y. Y.; Xu, G. Z.; Kaminskii, A. A.

    2013-08-01

    Direct generation of higher-order Ince-Gaussian (IG) beams from laser-diode end-pumped Cr, Nd:YAG self-Q-switched microchip lasers was achieved with high efficiency and high repetition rate. An average output power of over 2 W was obtained at an absorbed pump power of 8.2 W a corresponding optical-to-optical efficiency of 25% was achieved. Various IG modes with nanosecond pulse width and peak power of over 2 kW were obtained in laser-diode pumped Cr, Nd:YAG microchip lasers under different pump power levels by applying a tilted, large area pump beam. The effect of the inversion population distribution induced by the tilted pump beam and nonlinear absorption of Cr4+-ions for different pump power levels on the oscillation of higher-order IG modes in Cr, Nd:YAG microchip lasers is addressed. The higher-order IG mode oscillation has a great influence on the laser performance of Cr, Nd:YAG microchip lasers.

  19. Comparative study of excimer and erbium:YAG lasers for ablation of structural components of the knee

    NASA Astrophysics Data System (ADS)

    Vari, Sandor G.; Shi, Wei-Qiang; van der Veen, Maurits J.; Fishbein, Michael C.; Miller, J. M.; Papaioannou, Thanassis; Grundfest, Warren S.

    1991-05-01

    This study was designed to compare the efficiency and thermal effect of a 135 ns pulsed-stretched XeCl excimer laser (308 nm) and a free-running Erbium:YAG laser (2940 nm) with 200 microsecond(s) pulse duration for ablation of knee joint structures (hyaline and fibrous cartilage, tendon and bone). The radiant exposure used for tissue ablation ranged from 2 to 15 J/cm2 for the XeCl excimer and from 33 to 120 J/cm2 for Er:YAG. The excimer and Er:YAG lasers were operated at 4 and 5 Hz respectively. The ablative laser energy was delivered to tissue through fibers. Ablation rates of soft tissues (hyaline and fibrous cartilage, tendon) varied from 8.5 to 203 micrometers /pulse for excimer and from 8.2 to 273 micrometers /pulse for Er:YAG lasers. Ablation rates of soft tissues are linearly dependent on the radiant exposure. Within the range of parameters tested all the tissues except the bone could be rapidly ablated by both lasers. Bone ablation was much less efficient, requiring 15 J/cm2 and 110 J/cm2 radiant exposure for excimer and Er:YAG lasers to ablate 9.5 and 8.2 micrometers tissue per pulse. However, excimer laser ablation produced less thermal damage in the tissues studied compared to Er:YAG at the same laser parameters. The authors conclude that both lasers are capable of efficient knee joint tissue ablation. XeCl excimer laser requires an order of magnitude less energy than Er:YAG laser for comparable tissue ablation.

  20. Effect of the Crystal Environment on Side-Chain Conformational Dynamics in Cyanovirin-N Investigated through Crystal and Solution Molecular Dynamics Simulations

    PubMed Central

    Ahlstrom, Logan S.; Vorontsov, Ivan I.; Shi, Jun; Miyashita, Osamu

    2017-01-01

    Side chains in protein crystal structures are essential for understanding biochemical processes such as catalysis and molecular recognition. However, crystal packing could influence side-chain conformation and dynamics, thus complicating functional interpretations of available experimental structures. Here we investigate the effect of crystal packing on side-chain conformational dynamics with crystal and solution molecular dynamics simulations using Cyanovirin-N as a model system. Side-chain ensembles for solvent-exposed residues obtained from simulation largely reflect the conformations observed in the X-ray structure. This agreement is most striking for crystal-contacting residues during crystal simulation. Given the high level of correspondence between our simulations and the X-ray data, we compare side-chain ensembles in solution and crystal simulations. We observe large decreases in conformational entropy in the crystal for several long, polar and contacting residues on the protein surface. Such cases agree well with the average loss in conformational entropy per residue upon protein folding and are accompanied by a change in side-chain conformation. This finding supports the application of surface engineering to facilitate crystallization. Our simulation-based approach demonstrated here with Cyanovirin-N establishes a framework for quantitatively comparing side-chain ensembles in solution and in the crystal across a larger set of proteins to elucidate the effect of the crystal environment on protein conformations. PMID:28107510

  1. Effect of the Crystal Environment on Side-Chain Conformational Dynamics in Cyanovirin-N Investigated through Crystal and Solution Molecular Dynamics Simulations.

    PubMed

    Ahlstrom, Logan S; Vorontsov, Ivan I; Shi, Jun; Miyashita, Osamu

    2017-01-01

    Side chains in protein crystal structures are essential for understanding biochemical processes such as catalysis and molecular recognition. However, crystal packing could influence side-chain conformation and dynamics, thus complicating functional interpretations of available experimental structures. Here we investigate the effect of crystal packing on side-chain conformational dynamics with crystal and solution molecular dynamics simulations using Cyanovirin-N as a model system. Side-chain ensembles for solvent-exposed residues obtained from simulation largely reflect the conformations observed in the X-ray structure. This agreement is most striking for crystal-contacting residues during crystal simulation. Given the high level of correspondence between our simulations and the X-ray data, we compare side-chain ensembles in solution and crystal simulations. We observe large decreases in conformational entropy in the crystal for several long, polar and contacting residues on the protein surface. Such cases agree well with the average loss in conformational entropy per residue upon protein folding and are accompanied by a change in side-chain conformation. This finding supports the application of surface engineering to facilitate crystallization. Our simulation-based approach demonstrated here with Cyanovirin-N establishes a framework for quantitatively comparing side-chain ensembles in solution and in the crystal across a larger set of proteins to elucidate the effect of the crystal environment on protein conformations.

  2. Instrumentation For The Surgical Application Of The Nd:YAG Laser

    NASA Astrophysics Data System (ADS)

    Frank, F.; Bailer, P.; Beck, O.; Bowering, R.; Hofstetter, A.

    1984-03-01

    The Nd:YAG laser has become a coagulation instrument, which has found acceptance in interdisciplinary surgery. The main contributors are its highly efficient coagulation capability in interaction with tissue and the fact that the Nd:YAG laser beam can be transmitted by means of a simple quartz-glass fiber. Appropriate systems and instruments for transmission and operation have been developed for the various applications in neurosurgery, pulmology, gastroenterology, urology, gynaecology and dermatology. Operation methods in open and endoscopic surgery under use of several hand held devices and flexible as well as rigid endoscopes are being demonstrated by clinical examples of application.

  3. Growth and characterization of an efficient new NLO single crystal L-phenylalanine D-methionine for frequency conversion and optoelectronic applications

    NASA Astrophysics Data System (ADS)

    Sangeetha, P.; Jayaprakash, P.; Nageshwari, M.; Rathika Thaya Kumari, C.; Sudha, S.; Prakash, M.; Vinitha, G.; Lydia Caroline, M.

    2017-11-01

    Optically active single crystals of L-phenylalanine D-methionine (LPDM) were grown by slow evaporation technique by co-crystallization of amino acids L-phenylalanine and D-methionine in water. The unit cell dimensions have been identified from single crystal X-ray diffraction technique. The existences of various hydrocarbyls were examined by FTIR and FT-Raman spectroscopy. The carbon and hydrogen environment of the grown crystals were analyzed by FT NMR spectrum. The optical absorption studies show that the crystal is transparent in the visible region with a lower cut-off wavelength of 259 nm and there by optical band gap energy Eg is calculated to be 5.35 eV. The Urbach energy, extinction coefficient, reflectance were calculated from UV-absorption data. Further, the thermal stability and accurate melting point has been investigated by TG/DSC techniques. The Kurtz powder SHG was confirmed using Nd:YAG laser with fundamental wavelength of 1064 nm. The dielectric behavior of the specimen has been determined for various temperatures (313 K, 333 K, 353 K, 373 K) at different frequencies. Fluorescence study and the time resolved decay calculation was also performed for the LPDM crystal. Optical nonlinear susceptibility was measured in LPDM and the real and imaginary part of χ3 was evaluated by Z-scan technique using open and closed apertures.

  4. Nd:YAG laser system for ophthalmic microsurgery

    NASA Astrophysics Data System (ADS)

    Savastru, Dan; Ristici, Esofina; Dragu, T.; Cotirlan, C.; Miclos, Sorin; Mustata, Marina

    2005-04-01

    The Nd:YAG solid state laser can be used in ophthalmologic microsurgery because of its specific wavelength of 1064 nm, which has the property to penetrate the transparent medium of the eye. We design a specific ophthalmic system, containing a Q-switch Nd:YAG laser, an optical stereomicroscope and an aiming system. This laser-stereomicroscope system is used for eye examination and for microsurgical proceedings like posterior capsulotomy and pupilar membranectomy. We had to design an optical scheme of the laser to settle the radiation route. In order to cover the medical domain of the energies, we calibrate eleven attenuation filters using ratiometric method. For a correct position of the place where the laser pulse strikes, we used an original system consisting of two red laser diodes mounted on each side of the binocular One of the advantages of this laser system is taht the output energies can be varied widely (0.8-15 mJ), making a great numbers of applications in clinical ophthalmology possible.

  5. Nd:YAG vitreolysis and pars plana vitrectomy: surgical treatment for vitreous floaters.

    PubMed

    Delaney, Y M; Oyinloye, A; Benjamin, L

    2002-01-01

    To determine the efficacy of Nd:YAG vitreolysis and pars plana vitrectomy in the treatment of vitreous floaters. This is a single centre retrospective study of 31 patients (42 eyes) who underwent 54 procedures, Nd:YAG vitreolysis or pars plana vitrectomy, for the treatment of vitreous floaters between January 1992 and December 2000. Main outcome measures were percentage symptomatic improvement following treatment and incidence of post-operative complications. Statistical analysis was performed using the Fisher exact test. Posterior vitreous detachment was the primary cause of floaters in all 42 eyes with co-existing vitreous veils in three eyes and asteroid hyalosis in two eyes. Thirty-nine of 42 eyes received Nd:YAG vitreolysis. Thirty-eight percent found Nd:YAG vitreolysis moderately improved their symptoms while 61.5% found no improvement. After an average of 14.7 months follow-up no post-operative complications were recorded. Fifteen eyes underwent a pars plana vitrectomy, one with combined phacoemulsification and posterior chamber implantation and 11 following unsuccessful laser vitreolysis. Pars plana vitrectomy resulted in full resolution of symptoms in 93.3% of eyes. One patient developed a post-operative retinal detachment which was successfully treated leaving the patient with 6/5 VA. Patients' symptoms from vitreous floaters are often underestimated resulting in no intervention. This paper shows Nd:YAG vitreolysis to be a safe but only moderately effective primary treatment conferring clinical benefit in one third of patients. Pars plana vitrectomy, while offering superior results, should be reserved for patients who remain markedly symptomatic following vitreolysis, until future studies further clarify its role in the treatment of patients with floaters and posterior vitreous detachment.

  6. Resonantly pumped single-mode channel waveguide Er:YAG laser with nearly quantum defect limited efficiency.

    PubMed

    Ter-Gabrielyan, N; Fromzel, V; Mu, X; Meissner, H; Dubinskii, M

    2013-07-15

    We demonstrated the continuous-wave operation of a resonantly pumped Er:YAG single-mode channel waveguide laser with diffraction-limited output and nearly quantum defect limited efficiency. Using a longitudinally core-pumped, nearly square (61.2 μm×61.6 μm) Er3+:YAG waveguide embedded in an undoped YAG cladding, an output power of 9.1 W with a slope efficiency of 92.8% (versus absorbed pump power) has been obtained. To the best of our knowledge, this optical-to-optical efficiency is the highest ever demonstrated for a channel waveguide laser.

  7. Water-assisted pulsed Er:YAG laser interaction with silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Jaehun; Ki, Hyungson, E-mail: hski@unist.ac.kr

    2015-07-07

    Silicon is virtually transparent to the Er:YAG laser with a wavelength of 2.94 μm. In this study, we report that moderately doped silicon (1–10 Ω cm) can be processed by a pulsed Er:YAG laser with a pulse duration of 350 μs and a peak laser intensity of 1.7 × 10{sup 5} W/cm{sup 2} by applying a thin water layer on top of silicon as a light absorbing medium. In this way, water is heated first by strongly absorbing the laser energy and then heats up the silicon wafer indirectly. As the silicon temperature rises, the free carrier concentration and therefore the absorption coefficient of silicon willmore » increase significantly, which may enable the silicon to get directly processed by the Er:YAG laser when the water is vaporized completely. We also believe that the change in surface morphology after melting could contribute to the increase in the laser beam absorptance. It was observed that 525 nm-thick p-type wafer specimens were fully penetrated after 15 laser pulses were irradiated. Bright yellow flames were observed during the process, which indicates that the silicon surface reached the melting point.« less

  8. Variation on Molecular Structure, Crystallinity, and Optical Properties of Dentin Due to Nd:YAG Laser and Fluoride Aimed at Tooth Erosion Prevention

    PubMed Central

    Freitas, Anderson Z.; Bachmann, Luciano; Benetti, Carolina; Ana, Patricia A.

    2018-01-01

    This in vitro study evaluated the compositional, crystalline, and morphological effects promoted by Nd:YAG laser on root dentin, and verified the effects of laser and topical acidulated phosphate fluoride application (APF-gel) on dentin erosion. 180 bovine dentin slabs were randomized into 4 groups (n = 45): G1–untreated, G2–APF-gel (1.23% F−, 4 min), G3–Nd:YAG (1064 nm, 84.9 J/cm2, 10 Hz), and G4–APF-gel application followed by Nd:YAG laser irradiation. The compositional, crystalline, and morphological effects promoted by treatments were investigated on five samples of each experimental group. The other samples were submitted to a 5-day, 10-day, or 15-day erosive and abrasive demineralization and remineralization cycling in order to create erosion lesions. The area and depth of lesions, as well as the optical attenuation coefficient, were assessed, and all data were statistically analysed (p < 0.05). Nd:YAG laser promoted the reduction of carbonate, the formation of tetracalcium phosphate, as well as the melting and recrystallization of the dentin surface. Laser significantly decreased the area and depth of erosion lesions and altered the optical attenuation coefficient when compared to untreated and APF-gel groups, but the association of APF-gel and laser did not promote an additional effect. Nd:YAG laser irradiation can be a promissory treatment to prevent dentin erosion and the abrasion process. PMID:29389868

  9. An Investigation into the Polymorphism and Crystallization of Levetiracetam and the Stability of its Solid Form.

    PubMed

    Xu, Kailin; Xiong, Xinnuo; Guo, Liuqi; Wang, Lili; Li, Shanshan; Tang, Peixiao; Yan, Jin; Wu, Di; Li, Hui

    2015-12-01

    Levetiracetam (LEV) crystals were prepared using different solvents at different temperatures. The LEV crystals were systematically characterized by X-ray powder diffraction (XRPD) and morphological analysis. The results indicated that many kinds of crystal habits exist in a solid form of LEV. To investigate the effects of LEV concentration, crystallization temperature, and crystallization type on crystallization and solid phase transformation of LEV, multiple methods were performed for LEV aqueous solution to determine if a new solid form exists in solid-state LEV. However, XRPD data demonstrate that the LEV solid forms possess same spatial arrangements that are similar to the original solid form. This result indicates that the LEV concentration, crystallization temperature, and crystallization type in aqueous solution have no influence on the crystallization and solid phase transformation of LEV. Moreover, crystallization by sublimation, melt cooling, and quench cooling, as well as mechanical effect, did not result in the formation of new LEV solid state. During melt cooling, the transformation of solid form LEV is a direct process from melting amorphous phase to the original LEV crystal phase, and the conversion rate is very quick. In addition, stability investigation manifested that LEV solid state is very stable under various conditions. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  10. Low-cost Engineering of Laser Rods and Slabs with Liquid Phase Epitaxy

    DTIC Science & Technology

    2011-09-01

    SUPPLEMENTARY NOTES 14. ABSTRACT We investigated the use of a liquid phase epitaxial ( LPE ) coating to improve the performance of a rod or slab laser. A...single crystal erbium-doped yttrium aluminum garnet (Er:YAG) rod coated with undoped YAG, and an uncoated sample were procured, then compared on the...the whispering gallery modes, which otherwise would deplete the gain in ~50% of the rod volume. We also investigated LPE growth on a ceramic sample

  11. Optical Investigation of Nanoconfined Crystal Growth

    NASA Astrophysics Data System (ADS)

    Kohler, F.; Dysthe, D. K.

    2015-12-01

    Crystals growing in a confined space exert forces on their surroundings. This crystallization force causes deformation of solids and is therefore particularly relevant for the comprehension of geological processes such as replacement and weathering [1]. In addition, these forces are relevant for the understanding of damages in porous building materials caused by crystallization, which is of great economical importance and fundamental for methods that can help to preserve our cultural heritage [2,3]. However, the exact behavior of the growth and the dissolution process in close contact to an interface are still not known in detail. The crystallization, the dissolution and the transport of material is mediated by a nanoconfined water film. We observe brittle NaClO3 crystals growing against a glass surface by optical methods such as reflective interference contrast microscopy (RICM) [4]. In order to carefully control the supersaturation of the fluid close to the crystal interface, a temperature regulated microfluidic system is used (fig. A). The interference based precision of RICM enables to resolve distance variations down to the sub nanometer range without any unwanted disturbances by the measuring method. The combination of RICM with a sensitive camera allows us to observe phenomena such as periodic, wavelike growth of atomic layers. These waves are particularly obvious when observing the difference between two consecutive images (fig. B). In contradiction to some theoretical results, which predict a smooth interface, some recent experiments have shown that the nanoconfined growth surfaces are rough. In combination with theoretical studies and Kinetic Monte Carlo simulations we aim at providing more realistic descriptions of surface energies and energy barriers which are able to explain the discrepancies between experiments and current theory. References:[1] Maliva, Diagenetic replacement controlled by force of crystallization, Geology, August (1988), v. 16 [2] G

  12. Stress-induced waveguides in Nd:YAG by simultaneous double-beam irradiation with femtosecond pulses

    NASA Astrophysics Data System (ADS)

    Castillo, Gabriel R.; Romero, Carolina; Lifante, Ginés; Jaque, Daniel; Chen, Feng; Varela, Óscar; García-García, Enrique; Méndez, Cruz; Camacho-López, Santiago; Vázquez de Aldana, Javier R.

    2016-01-01

    We report on the fabrication of stress-induced waveguides in Nd:YAG (neodymium doped yttrium aluminum garnet, Nd:Y3Al5O12) by simultaneous double-beam irradiation with femtosecond laser pulses. An interferometer was used to generate two femtosecond laser beams that, focused with certain lateral separation inside the crystal, produced two parallel damage tracks with a single scan. The propagation of the mechanical waves simultaneously created in both focal spots produced a highly symmetrical stress field that is clearly revealed in micro-luminescence maps. The optical properties of the double-beam waveguides are studied and compared to those of single-beam irradiation, showing relevant differences. The creation of more symmetric stress patterns and a slight reduction of propagation losses are explained in terms of the fact that simultaneous inscription allows for a drastic reduction in the magnitude of "incubation" effects related to the existence of pre-damaged states.

  13. A new solid-state, frequency-doubled neodymium-YAG photocoagulation system.

    PubMed

    Jalkh, A E; Pflibsen, K; Pomerantzeff, O; Trempe, C L; Schepens, C L

    1988-06-01

    We have developed a solid-state laser system that produces a continuous green monochromatic laser beam of 532 nm by doubling the frequency of a neodymium-YAG laser wavelength of 1064 nm with a potassium-titamyl-phosphate crystal. Photocoagulation burns of equal size and intensity were placed in two rabbit eyes with the solid-state laser system and the regular green argon laser system, respectively, using the same slit-lamp mode of delivery. Histologic findings of lesion sections revealed no important differences between the two systems. In theory, the longer wavelength of the solid-state laser offers the advantages of less scattering in ocular media, higher absorption by oxyhemoglobin, and less absorption by macular xanthophyll than the 514-nm wavelength of the regular green argon laser. The solid-state laser has impressive technical advantages: it contains no argon-ion gas tube that wears out and is expensive to replace; it is much more power efficient, and thus considerably smaller and compact; it is sturdier and easily movable; it does not require external cooling; it uses a 220-V monophasic alternating current; and it requires little maintenance.

  14. Composite phase ceramic phosphor of Al₂O₃-Ce:YAG for high efficiency light emitting.

    PubMed

    Tang, Yanru; Zhou, Shengming; Chen, Chong; Yi, Xuezhuan; Feng, Yue; Lin, Hui; Zhang, Shuai

    2015-07-13

    We present our achievement which is a ceramic plate phosphorable to produce white light when directly combined with commercially available blue light emitting diodes. The ceramic phase structure is that the Al₂O₃ particle is uniformly distributed in the Ce:YAG matrix. The Al₂O₃-Ce:YAG ceramic phosphor has a better luminous efficacy than the transparent Ce:YAG ceramic phosphor under the same test condition. The Al₂O₃ particle plays an important role in promoting the luminous efficacy. The Al₂O₃ particle changes the propagation of the light in ceramic, and it reduces the total internal reflection. That is why the composite phase ceramic phosphor improves extraction efficiency of light.

  15. Q-switched pulse laser generation from double-cladding Nd:YAG ceramics waveguides.

    PubMed

    Tan, Yang; Luan, Qingfang; Liu, Fengqin; Chen, Feng; Vázquez de Aldana, Javier Rodríguez

    2013-08-12

    This work reports on the Q-switched pulsed laser generation from double-cladding Nd:YAG ceramic waveguides. Double-cladding waveguides with different combination of diameters were inscribed into a sample of Nd:YAG ceramic. With an additional semiconductor saturable absorber, stable pulsed laser emission at the wavelength of 1064 nm was achieved with pulses of 21 ns temporal duration and ~14 μJ pulse energy at a repetition rate of 3.65 MHz.

  16. Lack of adjunctive benefit of Er:YAG laser in non-surgical periodontal treatment: a randomized split-mouth clinical trial.

    PubMed

    Rotundo, Roberto; Nieri, Michele; Cairo, Francesco; Franceschi, Debora; Mervelt, Jana; Bonaccini, Daniele; Esposito, Marco; Pini-Prato, Giovanpaolo

    2010-06-01

    This split-mouth, randomized, clinical trial aimed to evaluate the efficacy of erbium-doped:yttrium-aluminium-garnet (Er:YAG) laser application in non-surgical periodontal treatment. A total of 27 patients underwent four modalities of non-surgical therapy: supragingival debridement; scaling and root planing (SRP)+Er:YAG laser; Er:YAG laser; and SRP. Each strategy was randomly assigned and performed in one of the four quadrants. Clinical outcomes were evaluated at 3 and 6 months. Subjective benefits of patients have been evaluated by means of questionnaires. Six months after therapy, Er:YAG laser showed no statistical difference in clinical attachment gain with respect to supragingival scaling [0.15 mm (95% CI -0.16; 0.46)], while SRP showed a greater attachment gain than the supragingival scaling [0.37 mm (95% CI 0.05; 0.68)]. No difference resulted between Er:YAG laser+SRP and SRP alone [0.05 mm (95% CI -0.25; 0.36)]. The adjunctive use of Er:YAG laser to conventional SRP did not reveal a more effective result than SRP alone. Furthermore, the sites treated with Er:YAG laser showed similar results of the sites treated with supragingival scaling.

  17. Temperature variation during apicectomy with Er:YAG laser.

    PubMed

    Bodrumlu, Emre; Keskiner, Ilker; Sumer, Mahmut; Sumer, A Pinar; Telcıoglu, N Tuba

    2012-08-01

    The purpose of this in vitro study was to evaluate the generated temperature of the Er:YAG laser, with three different pulse durations for apicectomy, compared with tungsten bur and surgical saw. Apicectomy is an endodontic surgery performed to remove the root apex and curette adjacent periapical tissue because of lesions of the apical area that are not healing properly. Sixty single-rooted extracted human teeth were resected by three cutting methods: tungsten bur, surgical saw, and Er:YAG laser irradiation with three different pulse durations; pulse duration 50 μs, pulse duration 100 μs, and pulse duration 300 μs. Teflon-insulated, type K thermocouples were used to measure temperature changes during the apicectomy process. Data were analyzed using the general linear models procedure of the SPSS statistical software program. Although there was no statistically significant difference for the mean values of temperature changes at 1 mm away to the cutting site of teeth, there was statistically significant difference among groups for the mean values of temperature changes at 3 mm away to the cutting site of teeth. Additionally, there was statistically significant difference among groups for the total time required for apicectomy. The laser irradiation with pulse duration 50 μs appears to have the lowest temperature rise and the shortest time required for apicectomy of the three pulse durations. However, Er:YAG laser for apicectomy in all pulse durations could be used safely for resection in endodontics in the presence of sufficient water.

  18. Effect of the PVA (polyvinyl alcohol) concentration on the optical properties of Eu-doped YAG phosphors

    NASA Astrophysics Data System (ADS)

    Hora, Daniela A.; Andrade, Adriano B.; Ferreira, Nilson S.; Teixeira, Verônica C.; dos S. Rezende, Marcos V.

    2016-10-01

    The influence of the polyvinyl alcohol (PVA) concentration on the synthesis and structural, morphological and optical properties of Y3Al5O13: Eu (Eu-doped YAG) was systematically investigated in this work. The final concentration of PVA in the preparation step influenced the crystallite size and also the degree of particle agglomeration in Eu-doped YAG phosphors. X-ray excited optical luminescence (XEOL) emission spectra results indicated typical Eu3+ emission lines and an abnormally intense 5D0 → 7F4. The intensity parameters Ω2 and Ω4 were calculated and indicated the PVA concentration affects the ratio Ω2:Ω4. X-ray absorption spectroscopy (XAS) results showed Eu valence did not change and the symmetry around the Eu3+ is influenced by the PVA concentration. XEOL-XAS showed the luminescence increases as a function of energy.

  19. Thermal-Mechanical Stability of Single Crystal Oxide Refractive Concentrators for High-Temperature Solar Thermal Propulsion

    NASA Technical Reports Server (NTRS)

    Zhu, Dongming; Jacobson, Nathan S.; Miller, Robert A.

    1999-01-01

    Single crystal oxides such as yttria-stabilized zirconia (Y2O3-ZrO2), yttrium aluminum garnet (Y3Al5O12, or YAG), magnesium oxide (MgO) and sapphire (Al2O3) are candidate refractive secondary concentrator materials for high temperature solar propulsion applications. However, thermo-mechanical reliability of these components in severe thermal environments during the space mission sun/shade transition is of great concern. Simulated mission tests are important for evaluating these candidate oxide materials under a variety of transient and steady-state heat flux conditions, and thus provide vital information for the component design. In this paper, a controlled heat flux thermal shock test approach is established for the single crystal oxide materials using a 3.0 kW continuous wave CO2 laser, with a wavelength 10.6 micron. Thermal fracture behavior and failure mechanisms of these oxide materials are investigated and critical temperature gradients are determined under various temperature and heating conditions. The test results show that single crystal sapphire is able to sustain the highest temperature gradient and heating-cooling rate, and thus exhibit the best thermal shock resistance, as compared to the yttria-stabilized zirconia, yttrium aluminum garnet and magnesium oxide.

  20. Thermal-Mechanical Stability of Single Crystal Oxide Refractive Concentrators for High-Temperature Solar Thermal Propulsion

    NASA Technical Reports Server (NTRS)

    Zhu, Dongming; Jacobson, Nathan S.; Miller, Robert A.

    1999-01-01

    Single crystal oxides such as yttria-stabilized zirconia (Y2O3-ZrO2), yttrium aluminum garnet (Y3Al5O12, or YAG), magnesium oxide (MgO) and sapphire (Al2O3) are candidate refractive secondary concentrator materials for high temperature solar propulsion applications. However, thermo-mechanical reliability of these components in severe thermal environments during the space mission sun/shade transition is of great concern. Simulated mission tests are important for evaluating these candidate oxide materials under a variety of transient and steady-state heat flux conditions, and thus provide vital information for the component design. In this paper, a controlled heat flux thermal shock test approach is established for the single crystal oxide materials using a 3.0 kW continuous wave CO2 laser, with a wavelength 10.6 micron. Thermal fracture behavior and failure mechanisms of these oxide materials are investigated and critical temperature gradients are determined under various temperature and heating conditions. The test results show that single crystal sapphire is able to sustain the highest temperature gradient and heating-cooling rate, and thus exhibit the best thermal shock resistance, as compared to the yttria-stabilized zirconia, yttrium aluminum garnet, and magnesium oxide.

  1. Diode pumped Nd:YAG laser development

    NASA Technical Reports Server (NTRS)

    Reno, C. W.; Herzog, D. G.

    1976-01-01

    A low power Nd:YAG laser was constructed which employs GaAs injection lasers as a pump source. Power outputs of 125 mW TEM CW with the rod at 250 K and the pump at 180 K were achieved for 45 W input power to the pump source. Operation of the laser, with array and laser at a common heat sink temperature of 250 K, was inhibited by difficulties in constructing long-life GaAs LOC laser arrays. Tests verified pumping with output power of 20 to 30 mW with rod and pump at 250 K. Although life tests with single LOC GaAs diodes were somewhat encouraging (with single diodes operating as long as 9000 hours without degradation), failures of single diodes in arrays continue to occur, and 50 percent power is lost in a few hundred hours at 1 percent duty factor. Because of the large recent advances in the state of the art of CW room temperature AlGaAs diodes, their demonstrated lifetimes of greater than 5,000 hours, and their inherent advantages for this task, it is recommended that these sources be used for further CW YAG injection laser pumping work.

  2. Loss of structural water and carbonate of Nd:YAG laser-irradiated human enamel.

    PubMed

    Corrêa-Afonso, Alessandra Marques; Bachmann, Luciano; de Almeida, Cíntia Guimarães; Dibb, Regina Guenka Palma; Borsatto, Maria Cristina

    2015-05-01

    The objective of this study was to use Fourier Transform Infrared (FTIR) spectroscopy and Scanning Electron Microscopy (SEM) to assess whether Nd:YAG laser irradiation associated with a dye or not alters the chemical constitution of the enamel. Fourteen enamel sections were randomly divided into two groups: (1) Nd:YAG and (2) dye + Nd:YAG. First, the untreated enamel surfaces were analyzed by FTIR to acquire the control absorption spectrum. Next, Group 2 received a layer of inactivated coal diluted in deionized water before laser treatment. Enamel samples belonging to groups 1 and 2 were then irradiated with a 1,064-nm Nd:YAG laser (80 mJ, 10 Hz) in the contact mode; the carbonate absorption band and the water absorption band were measured in each sample after irradiation. The water band was measured again 24 h, 48 h, and 7 days after irradiation. Group 1 had statistically similar water and carbonate contents before and after irradiation. Group 2 displayed significantly lower (p < 0.05) water content after irradiation, which remained constant along time at 24 and 48 h. After 7 days, the water content increased slightly, being statistically higher than in the other experimental periods, except for the control. The carbonate/phosphate ratio was measured only at the beginning, and after irradiation, it decreased only in Group 2 indicating carbonate loss (p < 0.05). Irradiation with 1,064-nm Nd:YAG laser associated with a dye reduces the carbonate and structural water content in the enamel.

  3. Growth and physicochemical properties of second-order nonlinear optical 2-amino-5-chloropyridinium trichloroacetate single crystals

    NASA Astrophysics Data System (ADS)

    Renugadevi, R.; Kesavasamy, R.

    2015-09-01

    The growth of organic nonlinear optical (NLO) crystal 2-amino-5-chloropyridinium trichloroacetate (2A5CPTCA) has been synthesized and single crystals have been grown from methanol solvent by slow evaporation technique. The grown crystals were subjected to various characterization analyses in order to find out the suitability for device fabrication. Single crystal X-ray diffraction analysis reveals that 2A5CPTCA crystallizes in monoclinic system with the space group Cc. The grown crystal was further characterized by Fourier transform infrared spectral analysis to find out the functional groups. The nuclear magnetic resonance spectroscopy is a research technique that exploits the magnetic properties of certain atomic nuclei. The optical transparency window in the visible and near-IR (200--1100 nm) regions was found to be good for NLO applications. Thermogravimetric analysis and differential thermal analysis were used to study its thermal properties. The powder second harmonic generation efficiency measurement with Nd:YAG laser (1064 nm) radiation shows that the highest value when compared with the standard potassium dihydrogen phosphate crystal.

  4. Er:YAG laser for the surgical treatment of the carpal tunnel syndrome

    NASA Astrophysics Data System (ADS)

    Russ, Detlef; Ebinger, Thomas; Illich, Wolfgang; Steiner, Rudolf W.

    2003-10-01

    We developed a new surgical procedure to improve the recurrence rate using an Er:YAG laser as dissection tool for the carpal ligament with the objective to ablate a small amount of the carpal ligament and to denaturate its ends. The Er:YAG Laser was transmitted to the applicator via a GeO fiber. With this system we proceeded 10 carpal ligament dissections without any complications in the follow-up period. All patients were free of pain and recurrence.

  5. Novel treatment of Hori's nevus: A combination of fractional nonablative 2,940-nm Er:YAG and low-fluence 1,064-nm Q-switched Nd:YAG laser.

    PubMed

    Tian, Brian Wei Cheng Anthony

    2015-01-01

    To demonstrate a combination laser therapy to treat Hori's nevus. A prospective study. A Singapore-based clinic. Five female patients, aged 30-46 years, with bilateral malar Hori's nevus. Photographs were taken before treatment and 1 month after laser treatment was completed. These were graded by three independent physicians. The patients were also asked to grade their treatment response subjectively. They were followed up for a total of 3 months after laser treatment to monitor recurrence. The fractional nonablative 2,940-nm Er:YAG laser with a fluence of 0.7 J/cm(2), spot size 12 mm, and frequency 15 Hz was used to perform a full-face single-pass treatment. Subsequently, a second pass and third pass over Hori's nevi were done bilaterally till the clinical endpoint of skin whitening. The 1,064-nm Q-switched (QS) Nd:YAG at a fluence of 2.0 J/cm(2), frequency 2 Hz, and 4-mm spot size was used to deliver multiple passes over Hori's nevus till erythema with mild petechiae appeared. We repeated the treatment once a week for 3 more consecutive weeks. All five patients had above 80% improvement in their pigmentation and two (skin type III) achieved complete 100% clearance. Based on the patients' subjective assessments, all five of them expressed satisfaction and felt that their pigmentation had improved. There were no complications noted. The fractional nonablative 2940 nm Er:YAG laser and Q-switched 1064nm laser Nd:YAG combination is an effective and safe treatment for Hori's nevus.

  6. Multiple minimally invasive Erbium:YAG laser mini-peels for skin rejuvenation: An objective assessment

    PubMed Central

    El-Domyati, Moetaz; El-Ammawi, Tarek S.; Medhat, Walid; Moawad, Osama; Mahoney, Mỹ G.; Uitto, Jouni

    2012-01-01

    Summary Background As the demand for minimally invasive rejuvenation is increasing, micro-peel resurfacing using Erbium:Yttrium Aluminium Garnet (Er:YAG ) laser 2940 nm has been reported for the treatment of photoaged skin without ablation of the epidermis. However, little is known about the efficacy and underlying histologic changes associated with this type of treatment. Aims The purpose of this study is to evaluate the clinical effect and objectively quantify the histological changes in response to multiple sessions of Er:YAG laser 2940 nm mini-peels. Patients and methods Six female volunteers of Fitzpatrick skin type III-IV and Glogau’s class I-III wrinkles were subjected to six microresurfacing peels at 2-week intervals using Er:YAG 2940 nm laser at sub-ablative fluences of 2 - 3 J/cm2 to treat periorbital rhytides. Quantitative evaluation of collagen types I, III and VII, newly synthesized collagen, total elastin and tropoelastin was performed by histochemistry and immunohistochemistry coupled with computerized morphometric analysis at base line, end of treatment, and three months post treatment. Results Compared to the base line, evaluation of volunteers revealed obvious clinical improvement in response to Er:YAG mini-peels. Collagen types I, III, and VII, as well as newly synthesized collagen, together with tropoelastin showed a statistically significant increase in response to treatment, while the mean level of total elastin was significantly decreased in response to treatment. However, this was followed by regression of improvement at 3 months post treatment, but was still better than baseline. Conclusions The present study revealed that multiple Er:YAG mini-peels is a promising treatment option for photoaging as it reverses the signs of photoaged skin with little downtime and side effects. However, to maintain the short term improvement achieved after treatment, continued Er:YAG 2940 nm laser mini-peels is required. PMID:22672276

  7. Treatment of onychomycosis using a 1064nm Nd:YAG laser.

    PubMed

    Noguchi, Hiromitsu; Miyata, Keishi; Sugita, Takashi; Hiruma, Midori; Hiruma, Masataro

    2013-01-01

    We investigated the efficacy of 1064nm Nd:YAG laser for the treatment of onychomycosis caused by dermatophytes. The study population consisted of 12 patients (6 male, 6 female ; average age 53.5 years), with onychomycosis confirmed by fungal culture and/or real-time PCR identification of the pathogen. The causative agent was identified as Trichophyton rubrum in 11 cases and a mixture of T. rubrum and T. mentagrophytes in 1 case. For each patient, laser treatment was given to a single hallux nail, with turbidity at baseline affecting <75% of the nail surface and thickness at baseline <3mm. Treatment was given in 3 sessions at 4-week intervals, and nail turbidity was evaluated 3 and 6 months after the first laser treatment. After 6 months the efficacy results were as follows: 3 cases, turbidity significantly improved ( >70%) ; 2 cases, turbidity improved (50-70%), 1 case, turbidity slightly improved (30-50%) ; 5 cases, no change in turbidity (<30% improvement) ; and 1 case, turbidity worsened. Overall, the total lesion area with turbidity in 12 patients decreased from 664.4mm(2) to 481.0mm(2), corresponding to a 27.6% improvement after treatment. Pain during laser treatment was well tolerated, and all patients underwent all 3 treatments. These results suggest that the 1064nm Nd:YAG laser could be a useful treatment alternative for patients with mild onychomycosis.

  8. Efficient eye-safe neodymium doped composite yttrium gallium garnet crystal laser.

    PubMed

    Yu, Haohai; Wang, Shuxian; Han, Shuo; Wu, Kui; Su, Liangbi; Zhang, Huaijin; Wang, Zhengping; Xu, Jun; Wang, Jiyang

    2014-03-15

    We report a laser-diode pumped continuous-wave (cw) and passively Q-switched eye-safe laser at about 1.42 μm with the neodymium-doped yttrium gallium garnet (Nd:YGG) crystal for the first time to our knowledge. The composite Nd:YGG crystal was developed originally. A systematic comparison of laser performance between the homogeneously doped and composite Nd:YGG crystal was made, which showed that the composite Nd:YGG manifested less thermally induced effects. Cw output power of 2.06 W was obtained with the slope efficiency of 20.7%. With a V:YAG as a saturable absorber, the passive Q-switching at 1.42 μm was gotten with the pulse width, pulse energy, and peak power of 34 ns, 46.7 μJ, and 1.4 kW, respectively. The present work should provide a potential candidate for the generation of eye-safe lasers.

  9. Short-term clinical results of knee arthroscopy utilizing the 1.44-um Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Maes, Kirk E.; Cummings, Robert S.; Mooar, Pekka A.; Sherk, Henry H.

    1994-09-01

    Two orthopedic surgeons performed 27 knee arthroscopies on 26 patients using the 1.44 micrometers Nd:YAG. Mean patient age was 52.6 years. Six patients had their entire procedure done using the Nd:YAG alone and 20 had their procedures done using both the laser and a conventional arthroscopic side-shaver. Three patients had an additional knee procedure done immediately following their arthroscopy. The mean operative procedure time was 47.25 minutes (SD equals 14.75). The mean energy setting used was 2.2 Joules/Pulse (SD equals 0.89), mean frequency 16.6 Hz (SD equals 6.4), and mean total energy delivered was 9418.7 Joules (SD equals 6032.5). There were 15 patients with a minimum follow-up of at least 4 weeks (mean 8.26 weeks). The final results showed 35% returned to normal baseline, 43% improved from pre-op condition, and 21% were the same as pre-op. None of the patients were worse. The 1.44 micrometers Nd:YAG has a water absorption coefficient nearly identical to the 2.1 micrometers Ho:YAG, which is currently a popular arthroscopic tool. We conclude that the 1.44 micrometers Nd:YAG is an effective alternative for arthroscopic procedures of the knee.

  10. Thermal, mechanical, optical and conductivity studies of a novel NLO active L-phenylalanine L-phenylalaninium dihydrogenphosphate single crystal

    NASA Astrophysics Data System (ADS)

    Sujatha, T.; Cyrac Peter, A.; Vimalan, M.; Merline Shyla, J.; Madhavan, J.

    2010-08-01

    An efficient, novel, semi-organic, nonlinear optical (NLO) material L-phenylalanine L-phenylalaninium dihydrogenphosphate (LPADHP), single crystal of dimension 11×5×2 mm 3, has been grown by the slow evaporation solution growth technique. Single crystal X-ray diffraction studies confirm that the grown crystal belongs to monoclinic system with the space group P2 1. The functional groups present in the crystal were confirmed by the Fourier transform infrared technique. Optical absorption spectrum shows that the material possesses very low absorption in the entire visible region. Thermal analysis confirmed that the crystal is thermally stable up to 161 °C. The frequency dependent dielectric properties of the grown crystal were studied for various temperatures. The second harmonic generation (SHG) efficiency of the grown crystal is 1.2 times greater than that of the potassium dihydrogenphosphate (KDP) single crystal. The laser induced surface damage threshold for the grown crystal was found to be 6.3 GW cm -2 with Nd:YAG laser assembly AC and DC conductivity and photoconductivity experiments are also carried out and the results are discussed.

  11. Growth and characterization of a new nonlinear optical organic crystal: 2,4,6-Trimethylacetanilide

    NASA Astrophysics Data System (ADS)

    Upadhyaya, V.; Prabhu, Sharada G.

    2015-09-01

    A new nonlinear optical organic material, 2,4,6-trimethylacetanilide (246TMAA), also known as N-[2,4,6- trimethylphenyl]acetamide, has been synthesized and grown as a single crystal by the slow evaporation technique by organic solvents. The grown crystals have been characterized by morphology study. The crystals are prismatic. Surface examination shows granular dendritic pattern in optical micrograph. The Scanning Electron Micrograph shows the layered growth of the crystal. The Differential Scanning Calorimeter plot shows no phase change until melting point (219°C). The density of the crystals is 1.1g/cc and the crystals are soft. The crystals are transparent in the visible region and in the ultra-violet region till 280 nm. 246TMAA crystallizes with 2 molecules in a monoclinic unit cell in the noncentrosymmetric point group m, space group Pn. Refractive indices of this optically biaxial crystal along the three crystallophysical axes have been measured at 633 nm. The optical second harmonic generation efficiency of the crystal at 1064 nm is about half that of the urea crystal, measured by powder method using Nd:YAG laser. The results show that the 246TMAA crystal can efficiently be used for up-conversion of infrared radiation into visible green light. The powder X-ray diffraction spectrum of the crystal has been obtained.

  12. Wavelength switchable high-power diode-side-pumped rod Tm:YAG Laser around 2µm.

    PubMed

    Wang, Caili; Du, Shifeng; Niu, Yanxiong; Wang, Zhichao; Zhang, Chao; Bian, Qi; Guo, Chuan; Xu, Jialin; Bo, Yong; Peng, Qinjun; Cui, Dafu; Zhang, Jingyuan; Lei, Wenqiang; Xu, Zuyan

    2013-03-25

    We report a high-power diode-side-pumped rod Tm:YAG laser operated at either 2.07 or 2.02 µm depending on the transmission of pumped output coupler. The laser yields 115W of continuous-wave output power at 2.07 µm with 5% output coupling, which is the highest output power for all solid-state 2.07 μm cw rod Tm:YAG laser reported so far. With an output coupler of 10% transmission, the center wavelength of the laser is switched to 2.02 μm with an output power of 77.1 W. This is the first observation of high-power wavelength switchable diode-side-pumped rod Tm:YAG laser around 2 µm.

  13. Neodymium:YAG laser cutting of intraocular lens haptics in vitro and in vivo.

    PubMed

    Feder, J M; Rosenberg, M A; Farber, M D

    1989-09-01

    Various complications following intraocular lens (IOL) surgery result in explantation of the lenses. Haptic fibrosis may necessitate cutting the IOL haptics prior to removal. In this study we used the neodymium: YAG (Nd:YAG) laser to cut polypropylene and poly(methyl methacrylate) (PMMA) haptics in vitro and in rabbit eyes. In vitro we were able to cut 100% of both haptic types successfully (28 PMMA and 30 polypropylene haptics). In rabbit eyes we were able to cut 50% of the PMMA haptics and 43% of the polypropylene haptics. Poly(methyl methacrylate) haptics were easier to cut in vitro and in vivo than polypropylene haptics, requiring fewer shots for transection. Complications of Nd:YAG laser use frequently interfered with haptic transections in rabbit eyes. Haptic transection may be more easily accomplished in human eyes.

  14. A systematic review of comparative studies of CO2 and erbium:YAG lasers in resurfacing facial rhytides (wrinkles).

    PubMed

    Chen, Kee-Hsin; Tam, Ka-Wai; Chen, I-Fan; Huang, Shihping Kevin; Tzeng, Pei-Chuan; Wang, Hsian-Jenn; Chen, Chiehfeng Cliff

    2017-08-01

    Laser resurfacing is used to minimize wrinkles, solar scars and sequelae of acne. Purpose of the systematic review was to compare resurfacing outcomes of CO 2 laser and erbium: yttrium aluminium garnet (erb:YAG) laser therapies. Medline, Cochrane Library, EMBASE and Google Scholar databases were searched until 9 April 2015 using the following terms: laser, carbon dioxide/CO 2 , facial wrinkles, rhytides and erbium-doped yttrium aluminium garnet/erbium:YAG/Er:YAG. Two-armed controlled split faced studies that compared CO 2 laser and erbium:YAG laser in patients with mild-to-moderate facial wrinkles or rhytides were included. The pooled data in this study and findings of other studies support the greater efficacy with the CO 2 laser in improving facial wrinkles, but the erb:YAG laser was associated with a better complication profile compared with the CO 2 laser. Except one case of hypopigmentation, other complications (i.e., erythema, hyperpigmentation and crusting) and their rates were reported by studies examining both lasers. In general, the CO 2 laser appeared to be more efficacious then the erb:YAG laser in treating facial wrinkles. Both lasers treatments were well tolerated.

  15. Regulatory role of XynR (YagI) in catabolism of xylonate in Escherichia coli K-12.

    PubMed

    Shimada, Tomohiro; Momiyama, Eri; Yamanaka, Yuki; Watanabe, Hiroki; Yamamoto, Kaneyoshi; Ishihama, Akira

    2017-12-01

    The genome of Escherichia coli K-12 contains ten cryptic phages, altogether constituting about 3.6% of the genome in sequence. Among more than 200 predicted genes in these cryptic phages, 14 putative transcription factor (TF) genes exist, but their regulatory functions remain unidentified. As an initial attempt to make a breakthrough for understanding the regulatory roles of cryptic phage-encoded TFs, we tried to identify the regulatory function of CP4-6 cryptic prophage-encoded YagI with unknown function. After SELEX screening, YagI was found to bind mainly at a single site within the spacer of bidirectional transcription units, yagA (encoding another uncharacterized TF) and yagEF (encoding 2-keto-3-deoxy gluconate aldolase, and dehydratase, respectively) within this prophage region. YagEF enzymes are involved in the catabolism of xylose downstream from xylonate. We then designated YagI as XynR (regulator of xylonate catabolism), one of the rare single-target TFs. In agreement with this predicted regulatory function, the activity of XynR was suggested to be controlled by xylonate. Even though low-affinity binding sites of XynR were identified in the E. coli K-12 genome, they all were inside open reading frames, implying that the regulation network of XynR is still fixed within the CR4-6 prophage without significant influence over the host E. coli K-12. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Comparative laser-tissue interaction effects at 1.96 and 2.01 um of Cr; Tm:YAG laser

    NASA Astrophysics Data System (ADS)

    Pankratov, Michail M.; Perrault, Donald F., Jr.; Shapshay, Stanley M.; Pinto, Joseph F.; Esterowitz, Dina; Aretz, H. Thomas

    1992-08-01

    A pulsed spiking and nonspiking Cr; thulium (Tm):YAG flash lamp pumped laser operating at 1.96 and 2.01 μm was investigated in vitro in the clinically relevant power range for its basic laser-tissue interaction with soft, cartilaginous, and bone tissues. Some explanations of the differences and possible medical applications are discussed.

  17. Nd:YAG end pumped by semiconductor laser arrays for free space optical communications

    NASA Technical Reports Server (NTRS)

    Sipes, D. L., Jr.

    1985-01-01

    Preliminary experimental results are reported for a diode-pumped Nd:YAG laser employing a tightly focused end-pump geometry. The resonator configuration is planoconcave, with the pumped end of the Nd:YAG rod being coated for high reflection at 1.06 microns. This geometry rectifies nearly all the inefficiencies plaguing side-pumped schemes. This laser is further considered as a candidate for optical communication over the deep space channel.

  18. The Construction of a Nd:YAG Laser and Observation of the Output.

    DTIC Science & Technology

    1983-12-01

    State Laser En ineering, p. 55, Springer-Verlag New York, Inc., 97.- 4. Koechner, W., p. 56. 5. Siegman , A. E., An Introduction to Lasers and Masers...AD-A138 855 THE CONSTRUCTION OF A ND YAG LASER AND OBSERVATION OF i/i THE OUTPUT(U) NAVAL POSTGRADUATE SCHOOL MONTEREY CAK H CHUNG DEC 83...CONSTRUCTION OF A Nd:YAG LASER AND OBSERVATION OF THE OUTPUT by Im. Ki Hyun Chung December 1983 Thesis Advisor: A. W. Cooper Approved for public release

  19. In vitro testing of Nd:YAG laser processed calcium phosphate coatings.

    PubMed

    De Carlos, A; Lusquiños, F; Pou, J; León, B; Pérez-Amor, M; Driessens, F C M; Hing, K; Best, S; Bonfield, W

    2006-11-01

    Nd:YAG laser cladding is a new method for deposition of a calcium phosphate onto metallic surfaces of interest in implantology. The aim of this study was to compare the biologic response of MG-63 human osteoblast-like cells grown on Ti-6Al-4V substrates coated with a calcium phosphate layer applied using different methods: plasma spraying as reference material and Nd:YAG laser cladding as test material. Tissue culture polystyrene was used as negative control. The Nd:YAG laser clad material showed a behaviour similar to the reference material, plasma spray, respective to cell morphology (SEM observations), cell proliferation (AlamarBlue assay) and cytotoxicity of extracts (MTT assay). Proliferation, as measured by the AlamarBlue assay, showed little difference in the metabolic activity of the cells on the materials over an 18 day culture period. There were no significant differences in the cellular growth response on the test material when compared to the ones exhibited by the reference material. In the solvent extraction test all the extracts had some detrimental effect on cellular activity at 100% concentration, although cells incubated in the test material extract showed a proliferation rate similar to that of the reference material. To better understand the scope of these results it should be taken into account that the Nd:YAG clad coating has recently been developed. The fact that its in vitro performance is comparable to that produced by plasma spray, a material commercially available for more than ten years, indicates that this new laser based method could be of commercial interest in the near future.

  20. Nd: YAG photodisruptors. American Academy of Ophthalmology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Nd: YAG laser surgery can cut lens capsule, vitreous and capsular membranes, strands, and adhesions, and the iris within the surgically unopened eye, thereby avoiding infection, wound leaks, and other complications of conventional intraocular surgery. The technique has found its most widespread use in performing posterior capsulotomies after extracapsular cataract surgery. It has an extremely low complication rate when used in the anterior segment and is a preferred alternative to surgical discission. The uncertainties regarding its safety in creating iridotomies in phakic eyes have lessened with its extensive use in patients with pupillary-block glaucoma. However, caution is urged in othermore » applications in phakic eyes. Following each Nd: YAG laser procedure, the eye should be monitored for elevation of intraocular pressure during the first two hours, and for retinal tears, retinal detachment, or cystoid macular edema during the first month after the procedure. Uncertainties persist regarding the circumstances under which the laser in its current configuration should be used in the vitreous cavity.« less

  1. Compact Nd:YAG laser operating at 1.06, 1.32, and 1.44 μm for dental caries effective disinfection

    NASA Astrophysics Data System (ADS)

    Dostálová, Tat'jana; Jelínková, Helena; Kadlecová, Martina; Němec, Michal; Å ulc, Jan; Fibrich, Martin; Nejezchleb, Karel; Kapitch, Nickalai; Å koda, Václav

    2017-02-01

    The analysis of the disinfection effect of Nd:YAG laser radiation was investigated for patients with high concentration of Streptococcus mutans in saliva (positive result in Saliva-check mutans test). For the interaction the Nd:YAG laser system generated separate switchable wavelengths with the maximum output energies 1.1, 0.6, and 0.3 J for wavelength 1.06 μm, 1.32, μm and 1.44 μm, respectively, was used. Our study proved that after the laser irradiation the Saliva-check test showed negative presence of Streptococcus mutans. The disinfection effect was confirmed for all used radiation wavelength. For 1.44 μm this effect was reached with a smallest energy density.

  2. Arthroscopic contact Nd:YAG laser meniscectomy: basic science, surgical technique, and clinical follow up

    NASA Astrophysics Data System (ADS)

    O'Brien, Stephen J.; Fealy, Stephen V.; Gibney, Mary A.; Miller, Drew V.; Kelly, Anne M.

    1990-06-01

    Recent basic science studies (5) have provided a scientific foundation for the use of the Contact Nd:YAG Laser as an arthroscopic tool for xneniscal resection and acroxnioplasty of the shoulder in a saline medium. This study prospectively evaluates the results of a three stage laboratory investigation as well as the clinical results of arthroscopic xneniscal resection. Fifteen patients with meniscal tears underwent subtotal meniscectomies utilizing a Contact Nd:YAG Laser (Surgical Laser Technologies; Malvern, Pennsylvania) . This was done in a saline medium with an average laser wattage of 25 W, (range 20 W to 30 W). Patients were evaluated postoperatively with reference to subjective and objective parameters at one week and four weeks postoperatively. Patients were evaluated with regard to wound healing, intraarticular swelling and pain. Assessment of technical parameters such as ease of resection, time of resection and instrument access were compared to conventional instruments. All fifteen patients were rated as having clinically excellent results based on pain relief, wound healing and swelling. In addition, although there was increased time with setting up the laser and calibrating it, there was not an increase in time for meniscal resection. Little, or no, secondary "trimmuning" was necessary with the laser. Increased accessibility was noted due to the small size of the laser. Arthroscopic Contact Nd:YAG Laser surgery is a safe and effective tool for menisca]. resection and coagulation in arthroscopic acromioplasties. It provides significant advantages over conventional cutting instruments with regard to accessibility and reduced need for secondary instruments.

  3. New long-wavelength Nd:YAG laser at 1.44 micron: effect on brain.

    PubMed

    Martiniuk, R; Bauer, J A; McKean, J D; Tulip, J; Mielke, B W

    1989-02-01

    A wavelength-shifted Nd:YAG laser, tuned to coincide with the infrared absorption peak of water at 1.44 microns, was used to make lesions in normal rabbit brain. A total of 48 lesions were made with power up to 20 W, with energy up to 40 joules, and with two different spot sizes. These lesions were compared to lesions made with 1.06 microns radiation from an Nd:YAG laser under identical operating conditions. Measurements of blood-brain barrier damage and width, depth, and volume of tissue affected were obtained 30 minutes after placement of the lesions. It was found that 1.44-microns lesions produced photoevaporative tissue loss at the highest intensities used. The layer of coagulated tissue remaining after photovaporization had a mean thickness of 0.6 mm irrespective of the volume of tissue removed. There was no photovaporization in the 1.06-microns lesions. In addition, the amount of peripheral edema per unit volume of tissue coagulated was approximately half at the 1.44-microns wavelength. These findings suggest that the 1.44-microns Nd:YAG laser may be a useful surgical instrument since it combines the photoevaporative effect of the CO2 laser while maintaining the advantages of the conventional Nd:YAG laser (quartz fiber delivery and effective hemostasis).

  4. Inhibition of enamel demineralisation using "Nd-YAG and diode laser assisted fluoride therapy".

    PubMed

    Chand, B R; Kulkarni, S; Mishra, P

    2016-02-01

    This in vitro study was to evaluate the irradiation efficacy of the Diode laser and the Nd-YAG laser either un-assisted or assisted by acidulated phosphate fluoride (APF) treatment on enamel's acid resistance. Seventy-two enamel samples, obtained from 12 extracted human molars, were randomly assigned to 6 groups as follows: (1) Control (C); (2) Exposed to APF gel (F); (3) Diode laser (DL); (4) Irradiated with Diode laser through APF gel (DL/F); (5) Nd-YAG laser (NL) and (6) Irradiated with Nd-YAG laser through APF gel (NL/F). The specimens were individually demineralised in an acidified hydroxyethylcellulose system, and the acid resistance was evaluated by determining the calcium ion dissolution using atomic absorption spectrometry. The average concentration of the calcium ion determined in groups 1 to 6 was 901, 757, 736, 592, 497 and 416 parts per million micrograms/gram, respectively. The results showed that demineralisation in the NL/F group was significantly less than the other groups and the control group was significantly greater than the other groups (P < 0.001). The effect of Nd-YAG laser irradiation, used alone or in combination with APF, in decreasing the enamel demineralisation was greater than all the other groups.

  5. Effects of a pulsed Nd:YAG laser on enamel and dentin

    NASA Astrophysics Data System (ADS)

    Myers, Terry D.

    1990-06-01

    Enamel and dentin samples were exposed extraorally to a pulsed neodymium yttriuma1uminumgarnet (Nd:YAG) laser. The lased samples were observed using both scanning electron microscopy and histological techniques to determine the effects of the laser. The present study has provided the following points: (1) Properly treated, enamel can be 1aser etched to a depth comparable to that achieved with phosphoric acid etching; and (2) both carious and noncarious dentin can be vaporized by the Nd:YAG laser. No cracking or chipping of any enamel or dentin sample was observed histologically or under the SEM.

  6. Investigation of the cluster formation in lithium niobate crystals by computer modeling method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voskresenskii, V. M.; Starodub, O. R., E-mail: ol-star@mail.ru; Sidorov, N. V.

    The processes occurring upon the formation of energetically equilibrium oxygen-octahedral clusters in the ferroelectric phase of a stoichiometric lithium niobate (LiNbO{sub 3}) crystal have been investigated by the computer modeling method within the semiclassical atomistic model. An energetically favorable cluster size (at which a structure similar to that of a congruent crystal is organized) is shown to exist. A stoichiometric cluster cannot exist because of the electroneutrality loss. The most energetically favorable cluster is that with a Li/Nb ratio of about 0.945, a value close to the lithium-to-niobium ratio for a congruent crystal.

  7. Tuning the sapphire EFG process to the growth of Al2O3/YAG/ZrO2:Y eutectic

    NASA Astrophysics Data System (ADS)

    Carroz, L.; Duffar, T.

    2018-05-01

    In this work, a model is proposed, in order to analytically study the working point of the Edge defined Film-fed Growth (EFG) pulling of crystal plates. The model takes into account the heat equilibrium at the interface and the pressure equilibrium across the meniscus. It is validated on an industrial device dedicated to the pulling of sapphire ribbons. Then, the model is applied to pulling ceramic alloy plates, of the ternary eutectic Al2O3/YAG/ZrO2:Y. This allowed understanding the experimental difficulties of pulling this new material and suggested improvements of the control software. From these results, pulling net shaped ceramic alloy plates was successful in the same industrial equipment as used for sapphire.

  8. Novel treatment of Hori's nevus: A combination of fractional nonablative 2,940-nm Er:YAG and low-fluence 1,064-nm Q-switched Nd:YAG laser

    PubMed Central

    Tian, Brian Wei Cheng Anthony

    2015-01-01

    Objective: To demonstrate a combination laser therapy to treat Hori's nevus. Design: A prospective study. Setting: A Singapore-based clinic. Participants: Five female patients, aged 30-46 years, with bilateral malar Hori's nevus. Measurements: Photographs were taken before treatment and 1 month after laser treatment was completed. These were graded by three independent physicians. The patients were also asked to grade their treatment response subjectively. They were followed up for a total of 3 months after laser treatment to monitor recurrence. Materials and Methods: The fractional nonablative 2,940-nm Er:YAG laser with a fluence of 0.7 J/cm2, spot size 12 mm, and frequency 15 Hz was used to perform a full-face single-pass treatment. Subsequently, a second pass and third pass over Hori's nevi were done bilaterally till the clinical endpoint of skin whitening. The 1,064-nm Q-switched (QS) Nd:YAG at a fluence of 2.0 J/cm2, frequency 2 Hz, and 4-mm spot size was used to deliver multiple passes over Hori's nevus till erythema with mild petechiae appeared. We repeated the treatment once a week for 3 more consecutive weeks. Results: All five patients had above 80% improvement in their pigmentation and two (skin type III) achieved complete 100% clearance. Based on the patients’ subjective assessments, all five of them expressed satisfaction and felt that their pigmentation had improved. There were no complications noted. Conclusion: The fractional nonablative 2940 nm Er:YAG laser and Q-switched 1064nm laser Nd:YAG combination is an effective and safe treatment for Hori's nevus. PMID:26865788

  9. High-frequency ultrasound evaluation of cellulite treated with the 1064 nm Nd:YAG laser.

    PubMed

    Bousquet-Rouaud, Regine; Bazan, Marie; Chaintreuil, Jean; Echague, Agustina Vila

    2009-03-01

    To investigate non-invasive laser treatment for cellulite using the 1064 nm Nd:YAG laser and to correlate clinical results with high-frequency skin ultrasound images. Twelve individuals of normal weight were treated on either the left or right posterior side of the thigh with the following parameters: fluence 30 J/cm, 18 mm spot size and dynamic cooling device pulse duration of 30 ms. Three treatments were performed at intervals of 3-4 weeks, and followed-up 1 and 3 months after the last session. Photographs and ultrasound imaging were assessed before each session. The 1064 nm Nd:YAG laser resulted in a tightening of the skin and an improvement in cellulite. No side effects were reported. High-resolution ultrasound imaging showed a significant improvement in dermis density and a reduction of dermis thickness. The method is described in detail in Appendix 1. Infra-red lasers may constitute a safe and effective treatment for cellulite and high-frequency ultrasound imaging provides a quantitative and objective measurement of the treatment efficacy.

  10. Investigation the effect of modification with nanopowders on crystallization process and microstructure of some alloys

    NASA Astrophysics Data System (ADS)

    Kuzmanov, P. M.; Popov, S. I.; Yovkov, L. V.; Dimitrova, R. N.; Cherepanov, A. N.; Manolov, V. K.

    2017-10-01

    Modified with nano-powders (NP), AlSi7Mg aluminum alloy, P265GH steel and GG25 gray cast iron, have been investigated. Thermal and metallographic analyses have been made. For modified AlSi7Mg alloy, reduction of overcooling and duration of crystallization at the initial crystallization and their increase at eutectic crystallization have been found. For cast iron GG25, reduction of overcooling at crystallization was established and for P265GH steel, overcooling was not recorded, only a change in the slope of the temperature dependence. The thermal effects obtained in the crystallization correspond to the refinement of micro- and macrostructures. A mathematical model for crystallization of samples for thermal analysis has been developed and solved.

  11. Soft-tissue applications of the holmium:YAG laser in urology

    NASA Astrophysics Data System (ADS)

    Denstedt, John D.; Razvi, Hassan A.; Chun, Samuel S.; Sales, Jack L.

    1995-05-01

    The ideal surgical laser for the treatment of soft tissue pathology should possess both ablative and hemostatic abilities. As well, for use in urologic conditions the laser must also be suitable for endoscopic use. The Holmium:YAG laser possesses these qualities and in preliminary clinical use has demonstrated a variety of potential urologic applications. In this study we review our initial experience with the Holmium:YAG laser over a 18 month period. A total of 51 patients underwent 53 procedures for a variety of soft tissue conditions including: bladder tumor ablation (25), incision of ureteral stricture (15), incision of urethral stricture (6), treatment of ureteropelvic junction obstruction (3), incision of bladder neck contracture (2), and ablation of a ureteral tumor (2). Satisfactory hemostasis was achieved in all cases. Procedures were considered successful (no further intervention being required to treat the condition) in 81% of the cases. Two patients with dense bladder neck contractures required electroincision under the same anesthetic for completion of the procedure. A single complication, that of urinary extravasation following incision of a urethral stricture resolved with conservative management. In summary, the Holmium:YAG laser has demonstrated safety and proficiency in the treatment of a variety of urologic soft tissue conditions.

  12. Spectroscopic and quantum chemical perspectives on 2-amino 5-methylpyridinium 4-nitrobenzoate - An organic single crystals for optoelectronics device applications

    NASA Astrophysics Data System (ADS)

    Gandhimathi, A.; Karunakaran, R. T.; Kumaran, A. Elakkina; Prabahar, S.

    2018-07-01

    In this work, an optical quality single crystals of 2-amino 5-methylpyridinium 4-nitrobenzoate (2A5MPNB) were grown by slow evaporation solution growth technique using methanol as a solvent. The phases and functional groups of 2A5MPNB have been confirmed through powder X-ray diffraction and Fourier transform infrared (FTIR) studies, respectively. The optical transmittance window and the lower cut-off wavelength of the 2A5MPNB have been identified by UV-Vis-NIR studies. Dielectric and photoconductivity studies were also performed for the grown crystals. In order to analyze the mechanical strength Vickers hardness studies were taken for the grown crystal. The thermal behaviour was investigated by TG/DTA studies. NLO and laser damage properties were explored using Nd:YAG laser. Moreover, the quantum chemical calculations on 2A5MPNB have been performed by density functional theory (DFT) calculations using the B3LYP method with 6-311++G(d,p) basis set. The predicted first hyperpolarizability is found to be 14.45 times greater than that of urea and suggests that the title compound could be an attractive material for nonlinear optical applications.

  13. Evaluation of Blood Cell Attachment on Er:Yag Laser Applied Root Surface Using Scanning Electron Microscopy

    PubMed Central

    CEKICI, Ali; MADEN, Ilay; YILDIZ, Sercan; SAN, Tangul; ISIK, Gulden

    2013-01-01

    Background: Periodontal regeneration is dependent on the uninterrupted adhesion, maturation and absorption of fibrin clots to a periodontally compromised root surface. The modification of the root surface with different agents has been used for better fibrin clot formation and blood cell attachment. It is known that Er:YAG laser application on dentin removes the smear layer succesfully. Aim: The aim of this study is to observe blood cell attachment and fibrin network formation following ER:YAG laser irradiation on periodontally compromised root surfaces in comparison to chemical root conditioning techniques in vitro. Materials and methods: 40 dentin blocks prepared from freshly extracted periodontally compromised hopeless teeth. Specimens were divided in 5 groups; those applied with PBS, EDTA, Citric acid and Er:YAG. They were further divided into two groups: those which had received these applications, and the control group. The specimens were evaluated with scanning electron microscope and micrographs were taken. Smear layer and blood cell attachment scoring was performed. Results: In the Er:YAG laser applied group, smear layer were totally removed. In the blood applied specimens, better fibrin clot formation and blood cell attachment were observed in the Er:YAG group. In the group that had been applied with citric acid, the smear layer was also removed. The smear layer could not be fully removed in the EDTA group. Conclusion: Er:YAG laser application on the root dentin seems to form a suitable surface for fibrin clot formation and blood cell attachment. Further clinical studies to support these results are necessitated. PMID:23533017

  14. Investigation on the growth and characterization of 4-aminobenzophenone single crystal by the vertical dynamic gradient freeze technique

    NASA Astrophysics Data System (ADS)

    Prabhakaran, SP.; Ramesh Babu, R.; Sukumar, M.; Bhagavannarayana, G.; Ramamurthi, K.

    2014-03-01

    Growth of bulk single crystal of 4-Aminobenzophenone (4-ABP) from the vertical dynamic gradient freeze (VDGF) setup designed with eight zone furnace was investigated. The experimental parameters for the growth of 4-ABP single crystal with respect to the design of VDGF setup are discussed. The eight zones were used to generate multiple temperature gradients over the furnace, and video imaging system helped to capture the real time growth and solid-liquid interface. 4-ABP single crystal with the size of 18 mm diameter and 40 mm length was grown from this investigation. Structural and optical quality of grown crystal was examined by high resolution X-ray diffraction and UV-visible spectral analysis, respectively and the blue emission was also confirmed from the photoluminescence spectrum. Microhardness number of the crystal was estimated at different loads using Vicker's microhardness tester. The size and quality of single crystal grown from the present investigation are compared with the vertical Bridgman grown 4-ABP.

  15. Investigation of selected structural parameters in Fe 95Si 5 amorphous alloy during crystallization process

    NASA Astrophysics Data System (ADS)

    Fronczyk, Adam

    2007-04-01

    In this study, we report on a crystallization behavior of the Fe 95Si 5 metallic glasses using a differential scanning cabrimetry (DSC), and X-ray diffraction. The paper presents the results of experimental investigation of Fe 95Si 5 amorphous alloy, subjected to the crystallizing process by the isothermal annealing. The objective of the experiment was to determine changes in the structural parameters during crystallization process of the examined alloy. Crystalline diameter and the lattice constant of the crystallizing phase were used as parameters to evaluate structural changes in material.

  16. “Skin-Core-Skin” Structure of Polymer Crystallization Investigated by Multiscale Simulation

    PubMed Central

    Ruan, Chunlei

    2018-01-01

    “Skin-core-skin” structure is a typical crystal morphology in injection products. Previous numerical works have rarely focused on crystal evolution; rather, they have mostly been based on the prediction of temperature distribution or crystallization kinetics. The aim of this work was to achieve the “skin-core-skin” structure and investigate the role of external flow and temperature fields on crystal morphology. Therefore, the multiscale algorithm was extended to the simulation of polymer crystallization in a pipe flow. The multiscale algorithm contains two parts: a collocated finite volume method at the macroscopic level and a morphological Monte Carlo method at the microscopic level. The SIMPLE (semi-implicit method for pressure linked equations) algorithm was used to calculate the polymeric model at the macroscopic level, while the Monte Carlo method with stochastic birth-growth process of spherulites and shish-kebabs was used at the microscopic level. Results show that our algorithm is valid to predict “skin-core-skin” structure, and the initial melt temperature and the maximum velocity of melt at the inlet mainly affects the morphology of shish-kebabs. PMID:29659516

  17. Fragmentation targeted at preferred discontinuities: A new concept in endolithotripsy with Holmium laser:YAG.

    PubMed

    Sánchez-Martín, F M; Emiliani, E; Pueyo-Morer, E; Angerri-Feu, O; Sanguedolce, F; Millán, F; Villavicencio, H

    2018-04-17

    There are currently 3holmium laser, YAG (Ho:YAG) endolithotripsy procedures that are considered basic (fragmentation, pulverisation, "pop-corn" technique). We present the technique of fragmentation targeted at preferred discontinuities (FTPD), a new concept of endolithotripsy by Ho:YAG laser. The FTPD technique is based on the selective application of energy (targeting a specific preselected point) to an area that is visually prone to the formation of a fracture line or preferred discontinuity (conditioned by the anisotropy of the urolithiasis). The ideal energy regimen (setting) is a high range of working energy (2-3J) with a very low frequency range (5-8Hz) and short pulse width. Between January 2015 to February 2017, the FTPD technique was used in 37 procedures (7 NLP, 16 RIRS, 12 URS, 2 cystolithotomies), with a Ho:YAG laser (Lumenis Pulse 120H ® , Tel-Aviv, Israel). Maximum power used: 24W (3J/8Hz) with fibres of 365μ and 273μ (URS, RIRS), and 32W (4J/8Hz) with fibres of 550μ (NLP, cystolithotomy). Strategic improvement was achieved in all cases using the TFPD technique to continue the endolithotripsy or remove fragments. No complications were recorded after the use of this method. FTPD can be considered a complementary option in combination with the basic methods of fragmentation and pulverisation. In our experience, it constitutes significant progress in optimising the performance of Ho:YAG laser endolithotripsy. Copyright © 2018 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. 2940-nm Er:YAG fractional laser enhanced the effect of topical drug for psoriasis.

    PubMed

    Li, Ruilian; Zhou, Jun; Su, Hui; Wang, Mei; Wang, Yongxian; Xiao, Shengxiang; Ma, Huiqun

    2017-08-01

    We observed the promoting effects of the 2940-nm erbium:YAG (Er:YAG) fractional laser in topical drug delivery for psoriasis. A total of five (four males and one female) recalcitrant psoriasis patients were given laser treatment eight times at 1-week intervals with the following parameters: 5-11% spot density and 100-μm energy depth. The psoriatic skin lesions on the left knee and the corresponding lesions at the right ones of each psoriasis patient were randomly divided into two groups: laser + topical drug group (L) and drug alone group (D). The psoriatic lesions in both groups were treated with the same topical treatment (calcipotriol ointment). The corresponding psoriatic lesions in the L group received extra 2940-nm Er:YAG laser irradiation before topical treatment. The photos of psoriatic lesions were taken before each treatment. The final photos were obtained from the patients at the seventh day after the final treatment. Drug alone or in combination with laser Er:YAG both reduced psoriatic lesions. However, with the increase in the number of treatments, increasing differences were observed between the treatment and the control sides. The therapeutic outcomes in the L groups were better than those in the D groups. Psoriasis area and severity index (PASI) scores for five cases of both groups were decreased. However, the scores in the L groups were lower than those in the D groups. The use of 2940 nm Er:YAG promoted the absorption of topical drugs for psoriasis, improving the therapeutic effect.

  19. New application of the long-pulsed Nd-YAG laser as an ablative resurfacing tool for skin rejuvenation: a 7-year study.

    PubMed

    Alshami, Mohammad Ali

    2013-09-01

    Carbon dioxide (CO2 ) and erbium-yttrium aluminum garnet (Er-YAG) lasers are the gold standards in ablative skin resurfacing. Neodymium-doped yttrium aluminum garnet (Nd-YAG) laser is considered a nonablative skin resurfacing laser whose usage is limited due to its high cost. To assess the efficacy and safety of Nd-YAG as an ablative resurfacing laser and to compare the results with those previously published for CO2 and Erbium-YAG lasers. A total of 296 patients (251 female and 45 male) with Fitzpatrick skin types III-IV and dermatological conditions amenable to ablative skin resurfacing participated in this study. Nd-YAG laser parameters assessed were wavelength (1064 nm), pulse duration (5 ms), fluence (10 J/cm(2) ), and spot size (8-10 mm). Efficacy of Nd-YAG laser was assessed by comparing pre- and posttreatment photographs. An improvement of 30-80% was observed in treated patients. The degree of improvement correlated positively with the number of laser sessions. The most common side effect was hyperpigmentation. Other side effects were less common and mild in intensity compared with published results for gold standard ablative lasers. Not only was the Nd-YAG laser found to be as effective as Er-YAG and CO2 lasers, but treated patients also had shorter recovery and treatment times, and at lower cost. © 2013 Wiley Periodicals, Inc.

  20. Czochralski and modified Bridgman-Stockbarger growth of pure, Cd 2+ and Nd 3+ doped benzil single crystals

    NASA Astrophysics Data System (ADS)

    Aggarwal, M. D.; Wang, W. S.; Tambwe, M.

    1993-03-01

    Pure, Cd2+ and Nd3+-doped benzil C6H5COCOC6H5 have been grown from melt using the Czochralski and modified Bridgman-Stockbarger methods. Angle-tuned second harmonic generation of pure benzil from Nd:YAG laser radiation of λ = 1.06 μm with a conversion efficiency η = I2w/Iw = 0.4% has been demonstrated. We have used a Nd:YAG pulse laser to measure the radiation damage threshold as 15.9 MW/cm2 (c-axis) and 23.9 MW/cm2 (a-axis) under the conditions that laser pulse width is 10 ns. Under the same conditions, the conversion efficiency of Nd3+ and Cd2+-doped benzil, η= I2w/Iw = 1.1%, has been demonstrated. The radiation threshold is higher than for pure benzil crystals.

  1. In vitro study of the variable square pulse Er:YAG laser cutting efficacy for apicectomy.

    PubMed

    Grgurević, Josko; Grgurević, Lovro; Miletić, Ivana; Karlović, Zoran; Krmek, Silvana Jukić; Anić, Ivica

    2005-06-01

    Variable square pulse (VSP) Er:YAG laser should be quicker than older Er:YAG lasers. The objectives were: (1) comparison of VSP laser and mechanical handpiece efficacy for apicectomy and (2) determination of optimal pulse width/energy/frequency combination. Sixty extracted, single-rooted mature human teeth with round apical parts were instrumented, root filled, cleaned, and divided into four groups. Apical 2 mm of each root were apicectomized with mechanical handpiece and Er:YAG laser with three different settings (LaserA = 200 mJ/300 microseconds/ 8 Hz; LaserB = 200 mJ/100 microseconds/8 Hz; LaserC = 380 mJ/100 microseconds/20 Hz). Timing results were statistically compared. LaserC was the most efficient setting. Differences between groups were significant except between LaserC-Mechanical and LaserA-LaserC (P < 0.05). VSP Er:YAG laser used for apicectomy is slower by a factor of 7-31 than mechanical handpiece, but treatment outcome is acceptable. Optimal settings for apicectomy with VSP laser are 380 mJ/100 microseconds/20 Hz. Copyright 2005 Wiley-Liss, Inc.

  2. Healing process of vascular cutting edge using an Nd:YAG laser bipolar dissector.

    PubMed

    Morita, T; Ishida, K; Ookubo, K; Tanaka, K; Nakamura, H; Daikuzono, N

    1995-08-01

    The wound healing process was histopathologically investigated in a rabbit femoral artery (n = 48) after transection using a laser bipolar dissector (LBD, 1064nm the Nd:YAG bipolar contact laser) with laser power of 13W in 0.5-sec pulses. The cutting edges were harvested immediately (n = 6) and at 1 (n = 6), 4 (n = 6), and 7 (n = 6) days, 2 (n = 6), 3 (n = 6), and 4 (n = 6) weeks, and 6 months (n = 6), and evaluated by light microscopy. During the postoperative period, no perforation was seen in the 48 transected sites with the LBD. The healing process after LBD transection was accomplished within 2 weeks by organization of the intraluminal thrombus and by the formation of granulation tissue outside the adventitia of vessels. Characteristic morphological changes after LBD transection were recognized in the tapering area, i.e., cartilage and bone formation. Cartilaginous foci (n = 6) were observed in the media at 4 weeks after transection, and osseous foci (n = 3) in subendothelial space at 6 months. These observations may suggest that the heterotopic cartilaginous and osseous metaplasia of a vessel wall may be a result of the biostimulative effects of the Nd:YAG laser.

  3. Diode-pumped continuous-wave eye-safe Nd:YAG laser at 1415 nm.

    PubMed

    Lee, Hee Chul; Byeon, Sung Ug; Lukashev, Alexei

    2012-04-01

    We describe the output performance of the 1415 nm emission in Nd:YAG in a plane-concave cavity under traditional pumping into the 4F5/2 level (808 nm) and direct in-band pumping into the 4F3/2 level (885 nm). An end-pumped Nd:YAG laser yielded maximum cw output power of 6.3 W and 4.2 W at 885 nm and 808 nm laser diode (LD) pumping, respectively. To the best of our knowledge, this is the highest output power of a LD-pumped 1415 nm laser.

  4. Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

    NASA Technical Reports Server (NTRS)

    Decker, Arthur J.

    1989-01-01

    The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

  5. An expanded study of long-pulsed 1064 nm Nd:YAG laser treatment of basal cell carcinoma.

    PubMed

    Ortiz, Arisa E; Anderson, R Rox; DiGiorgio, Catherine; Jiang, Shang I Brian; Shafiq, Faiza; Avram, Mathew M

    2018-02-13

    Basal cell carcinoma (BCC) is an indolent form of skin cancer that is rarely life threatening, but can cause significant cosmetic and functional morbidity. Surgical treatments often result in disfiguring scars, while topical therapies frequently result in recurrence. The need for a more effective nonsurgical alternative has led to the investigation of laser treatment of BCC. We have previously conducted a pilot study which showed 100% histologic clearance at high fluences. Treatments were well tolerated with no significant adverse events. The objective of this larger study was to confirm preliminary results that the 1064 nm Nd:YAG laser is a safe and effective method for treating non-facial BCC. This is an IRB-approved, prospective, multi-center study evaluating the safety and efficacy of the 1064 nm Nd:YAG laser for the treatment of BCC on the trunk and extremities. Thirty-three subjects seeking treatment for biopsy-proven BCC that did not meet the criteria for Mohs surgery were recruited. Subjects on current anticoagulation therapy, or with a history of immunosuppression were excluded. Subjects received one treatment with the 1064 nm Nd:YAG laser as follows: 5-6 mm spot, fluence of 125-140 J/cm 2 and a pulse duration of 7-10 ms. Standard excision with 5 mm clinical margins was performed at 30 days after laser treatment to evaluate clinical and histologic clearance of BCC. Standardized photographs and adverse assessments were taken at the baseline visit, immediately after laser treatment and on the day of excision. Thirty-one subjects completed the study. BCC tumors had a 90% (28 of 31 BCC tumors) histologic clearance rate after one treatment with the long-pulsed 1064 nm Nd:YAG laser. Treatments were generally well tolerated without any anesthesia. Immediate side effects included edema and erythema. At 1-month follow-up, some patients had residual crusting. No significant adverse events occurred. The 1064 nm long-pulsed Nd:YAG laser is an

  6. Combined pulsed dye laser and fiberoptic Nd-YAG laser for the treatment of hypertrophic port wine stain.

    PubMed

    Radmanesh, Mohammed; Radmanesh, Ramin

    2017-10-01

    The hypertrophic Port Wine Stain (PWS) is only partially and superficially treated with the Pulsed dye laser (PDL) because of its limited depth of penetration. We used combined PDL and fiberoptic 1444-nm Nd-YAG laser to treat a case with hypertrophic PWS. After tumescent anesthesia, few holes were made by a 16-gauge needle on different sides of the lesion. The fiberoptic tip of 1444-nm Nd-YAG laser was inserted within the holes and was pushed forward while triggering. In a fan pattern and by a back and forth movement, the subcutaneous and deep dermal areas were coagulated. The skin and outer mucosal surfaces were then treated by PDL. The fiberoptic system used was Accusculpt 1444-nm Nd-YAG laser (Lutronic lasers, South Korea), and the PDL used was 585 nm Nlite system (Chromogenex UK). The parameters used for PDL were fluence = 9 Joules/cm 2 and the spot size was 5 mm. The parameters used for fiberoptic 1444-nm Nd-YAG laser were: Pulse rate = 30 Hz, pulse energy = 300 mJ, power = 6 W, and the total energy = 4000 J for the whole face and mucosa. Little sign of regression and moderate purpura were detected immediately after combined fiberoptic Nd-YAG and PDL therapy. The lesion gradually regressed within 4 months with satisfactory color and volume change. Combined fiberoptic Nd-YAG laser and PDL can be used for the treatment of deeper and superficial layers of hypertrophic PWS.

  7. [Intraocular pressure after ND: YAG laser capsulotomy in pseudophakic patients with glaucoma].

    PubMed

    Sesar, Antonio; Petric, Irena; Sesar, Ivanka; Lacmnovic-Loncar, Valentina; Jurisić, Darija; Tomić, Zeljka; Mandić, Zdravko

    2006-01-01

    The aim of the study was to analyze changes in intraocular pressure after Nd: YAG laser capsulotomy in pseudophakic patients with glaucoma. Intraocular pressure was recorded before, and 1 and 3 hours after YAG laser capsulotomy in 69 pseudophakic patients with glaucoma. Twenty eight patients received no therapy before capsulotomy, 21 patients received topical brimonidine 0.2%, and 20 patients received topical dorzolamide 2% 1 hour before laser capsulotomy. All patients received topical tropicamide 1% and tetracaine 0.5%. Nd: YAG laser posterior capsulotomy was performed using inverted-U technique to make a 3-4 mm diameter capsulotomy. After capsulotomy, all eyes received topical fluorometholone for 10 days. A pressure rise was greater in patients without any therapy before YAG laser capsulotomy. Eight patients with glaucoma showed intraocular pressure rise of 5 mm Hg, and 2 patients pressure rise of 10 mm Hg after laser capsulotomy. A reduction of intraocular pressure rise was found in patients who received dorzolamide 2% or brimonidine 0.2%, only 1 patient in each group developed a pressure rise of 5 mm Hg. In all patients a significant pressure rise developed within the first hour. It is difficult to compare different studies due to different techniques of cataract surgery and different intraocular lense material and design. Barnes showed that 6 of 29 (21%) developed a pressure rise of 5 mm Hg, and 1 of 29 (3%) patients a pressure rise of 10 mm Hg. In our study, 29% of patients had a pressure rise of > or =5 mm Hg, and 7% of patients had a rise of > or =10 mm Hg after laser capsulotomy. These results may be associated with a large proportion of extracapsular cataract extraction (71%) versus phacoemulsification (29%) in our patients. Pretreatment with dorzolamide 2% or brimonidine 0.2% reduce the intraocular pressure rise after Nd: YAG laser capsulotomy in pseudophakic patients with glaucoma.

  8. Dielectric, optical and mechanical studies of phenolic polyene OH1 organic electrooptic crystal

    NASA Astrophysics Data System (ADS)

    Bharath, D.; Kalainathan, S.

    2014-11-01

    2-{3-[2-(4-Hydroxyphenyl) vinyl]-5, 5-dimethylcyclo-hex-2-en-1-ylidene}malononitrile (OH1) phenolic locked polyene organic material has been synthesized by the Knoevenagel condensation method. OH1 single crystals were grown in methanol by a slow evaporation method. In order to avoid the multinucleation and reduce the metastable zone width, phosphoric acid is added in different concentrations. The linear optical property of OH1 crystal has been studied using UV-vis-NIR spectroscopy in the wavelength range 190-1100 nm and optical constants are calculated theoretically. The magnitude of nonlinear refractive index (10-12 m2/W), nonlinear absorption (10-6 m/W) and third order nonlinear susceptibility (10-6 esu) has been studied using a Z-scan technique. Dielectric property of OH1 crystal has been studied in frequency range 50 Hz-5 MHz. Photoluminescence spectrum was recorded using a xenon lamp in the range of 450-700 nm. Laser optical damage threshold of OH1 crystal was obtained (0.62 GW/cm2) using a pulsed Nd-YAG laser (1064 nm) of repetition rate 10 ns.

  9. The regeneration of thermal wound on mice skin (Mus Musculus) after Q-Switch Nd: YAG laser irradiation for cancer therapy candidate

    NASA Astrophysics Data System (ADS)

    Apsari, R.; Nahdliyatun, E.; Winarni, D.

    2017-09-01

    The aims of this study are to investigate the regeneration of mice skin tissue (Mus Musculus) irradiated by Q-Switch Nd: YAG laser and morphological change due to Q-Switch Nd: YAG laser irradiation compared to conventional heating (hairdryer). The 2-3 month of twenty-seven mice were used for experimental animals. Mice were incised in the dorsum by the damage effect of laser energy dose (therapeutic dose) of 29.5 J/cm2 with 10 seconds of exposure time, 10 Hz of repetition rate, and 100 pulses of the given single pulse energy. The mice skin tissue was injuried by hairdryer to get burned effect. Mice were divided into three groups, Group I (control) were not treated by anything, Group II were treated by Q-Switch Nd: YAG laser irradiation and sacrificed on (0, 1, 3, 5) days, and Group III were treated by hairdryer then sacrificed on (0, 1, 3, 5) days. Pathology examination showed that the energy of 29,5 J/cm2 dose produced the hole effect (ablation) through the hypodermic layer caused by optical breakdown and collagen coagulation. Thus, the 60 °C temperature of burn showed coagulation necrosis because piknosis discovered in the injured area. The regeneration process showed that the mice skin tissue's ability to regenerate was irradiated by fast laser because of the focus of Q-Switch Nd: YAG laser. It was showed by the scab releases on third day and completely reepithelialization formation on the fifth day. The collagen fibers distribution was same as normal skin tissue on day 5 and so did angiogenesis. Therefore, Q-Switch Nd: YAG laser can be applied for problems of dermatology medical therapies, especially melasma, nevus of ota and tatto therapy. For skin cancer therapy application, energy dose of unregenerated skin tissue is chosen because the death expected effect is permanent.

  10. Contact Nd:YAG tonsillectomy: effects on weight loss and recovery.

    PubMed

    Maloney, R W

    1991-01-01

    Contact Nd:YAG tonsillectomy using synthetic sapphire blades appears to meet or exceed standards established by spot monopolar cautery. Subjects' percentage of weight loss and return to work/social activities was measured and the laser group displayed less percentage of weight loss, faster return to pre-operative weight, and less recovery time than the comparative cautery group. Because of the unique nature of Nd:YAG laser light combined with sapphire blades, special consideration should be given to these accessories by physicians before attempting tissue cutting and vessel coagulation. The author believes that the extent of physician training and proficiency may be key to the success of soft tissue head and neck applications, such as tonsillectomy, which will have an effect on the outcome of clinical data.

  11. Growth and characterization of Methyl 2-amino-5-bromobenzoate crystal for NLO applications

    NASA Astrophysics Data System (ADS)

    Parthasarathy, M.; Gopalakrishnan, R.

    2012-11-01

    Good quality single crystal of organic Methyl 2-amino-5-bromobenzoate (M2A5B) was grown using slow evaporation solution growth technique. The grown crystal was confirmed by single crystal X-ray diffraction. The functional groups and vibrational frequencies were identified using FT-IR and FT-Raman spectral analyses. The presence of hydrogen and carbon atoms in the grown sample was confirmed with proton and carbon NMR spectral studies. The optical energy band gap of the title compound is found to be 2.7 eV from the optical transmission spectra. The refractive indices nx, ny, and nz were found to be 1.569, 1.587 and 1.600, respectively using Brewster's angle method. The melting point of the material obtained with melting point apparatus is 74 °C. Thermal stability of the grown crystal was studied by thermogravimetric analysis (TGA) and differential thermal analysis (DTA). The mechanical behaviour of the grown crystal was analyzed with Vicker's microhardness tester. The particle size dependent second harmonic generation efficiency for M2A5B was evaluated by Kurtz-Perry powder method using Nd:YAG laser, which established the existence of phase matching.

  12. Temperature tuning of lasing emission from dye-doped liquid crystal at intermediate twisted phase

    NASA Astrophysics Data System (ADS)

    Liao, Kuan-Cheng; Lin, Ja-Hon; Jian, Li-Hao; Chen, Yao-Hui; Wu, Jin-Jei

    2015-07-01

    Temperature tuning of lasing emission from dye-doped cholesteric liquid crystal (CLC) at intermediate twisted phase has been demonstrated in this work. With heavily doping of 42.5% chiral molecules into the nematic liquid crystals, the shifts of photonic bandgap versus temperature is obviously as thermal controlling of the sample below the certain value. By the differential scanning calorimetr measuremet, we demonstrate the phase transition from the CLC to the smectic phase when the temperature is lowered to be about 15°C. Between CLC and smectic phase, the liquid crystal mixtures are operated at intermediate twisted phase that can be used the temperature related refractive mirror. After pump by the Q-switched Nd:YAG laser, the lasing emission from this dye doped LC mixtures has been demonstrated whose emission wavelength can be tuned from 566 to 637 nm with 1.4°C variation.

  13. Potential emerging treatment in vitiligo using Er:YAG in combination with 5FU and clobetasol.

    PubMed

    Mokhtari, Fatemeh; Bostakian, Anis; Shahmoradi, Zabihollah; Jafari-Koshki, Tohid; Iraji, Fariba; Faghihi, Gita; Hosseini, Sayed Mohsen; Bafandeh, Behzad

    2018-04-01

    Vitiligo is a pigmentary disorder of skin affecting at least 1% of the world population of all races in both sexes. Its importance is mainly due to subsequent social and psychological problems rather than clinical complications. Various treatment choices are available for vitiligo; however, laser-based courses have shown to give more acceptable results. The aim of this trial was to evaluate the efficacy of Er:YAG laser as a supplementary medicine to topical 5FU and clobetasol in vitiligo patients. Two comparable vitiligo patches from 38 eligible patients were randomized to receive topical 5FU and clobetasol in control group and additional Er:YAG laser in intervention group. Major outcomes of interest were the size of patch and pigmentation score at randomization and 2 and 4 months after therapy. Final sample included 18 (47%) male patients and age of 35.66±8.04. The performance Er:YAG group was superior in all sites. Reduction in the size of patches was greater in Er:YAG group (p-value=.004). Also, this group showed a higher pigmentation scores in the trial period than control group (p-value<.001). Greater reduction in the size and increase in pigmentation score was seen in Er:YAG group especially for short periods after therapy and repeating laser sessions may help improving final outcomes. Er:AYG could help in reducing complications of long-term topical treatments, achieving faster response, and improving patient adherence. © 2017 Wiley Periodicals, Inc.

  14. Er:YAG laser for endodontics: efficiency and safety

    NASA Astrophysics Data System (ADS)

    Hibst, Raimund; Stock, Karl; Gall, Robert; Keller, Ulrich

    1997-12-01

    Recently it has been shown that bacterias can be sterilized by Er:YAG laser irradiation. By optical fiber transmission the bactericidal effect can also be used in endodontics. In order to explore potential laser parameters, we further investigated sterilization of caries and measured temperatures in models simulating endodontic treatment. It was found out that the bactericidal effect is cumulative, with single pulses being active. This offers to choose all laser parameters except pulse energy (radiant exposure) from technical, practical or safety considerations. For clinical studies the following parameter set is proposed for efficient and safe application (teeth with a root wall thickness > 1 mm, and prepared up to ISO 50): pulse energy: 50 mJ, repetition rate: 15 Hz, fiber withdrawal velocity: 2 mm/s. With these settings 4 passes must be performed to accumulate the total dose for sterilization.

  15. Time-of-flight spectroscopy characterization of the plasma plume from a laser-ablated potassium titanyl phosphate crystal

    NASA Astrophysics Data System (ADS)

    Ying, Minju; Wang, XiaoXiao; Cheng, Wei; Liao, Bin; Zhang, Xu

    2015-06-01

    Optical emission spectra of the plasma produced by 1.06-μm Nd:YAG laser irradiation of a potassium titanyl phosphate (KTP) crystal were recorded and analyzed in a time- and spatially resolved manner. The composition and evolution of the plasma plume were studied in low vacuum conditions. Emission lines associated with Ti(I), Ti(II) and K(I) were identified in the plasma. The delay times of emission peaks for the ablated species were investigated as a function of the observation distance from the target surface, and the velocities of these species were derived accordingly. Two emission peaks corresponding to a fast and a slow component of ablated Ti(I) were observed by optical time-of-flight spectroscopy. The origins of the two peaks and a possible mechanism for the laser ablation are discussed.

  16. 1.44-μm giant pulse generation

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Arátor, Pavel; Jelínková, Helena; Nejezchleb, Karel; Škoda, Václav

    2007-02-01

    We have compared two solid-state saturable absorbers for Q-switching of longitudinally diode-pumped Nd:YAG laser operating at wavelength 1444 nm: vanadium doped garnet (V 3+:Y 3Al IIO 5, V:YAG), and cobalt doped spinel (Co 2+:MgAl IIO 4, Co:MALO). V:YAG crystal with initial transmission 91% was 2.2mm thick. Co:MALO crystal with initial transmission 91% was 2.0mm thick. Q-switched laser consisted of the Nd:YAG composite rod (8mm long Nd-doped part, 4mm long undoped YAG part) and the saturable absorber placed in 80mm long hemispheric cavity. As an output coupler was used concave mirror (r = 150mm) with reflectivity 98% on lasing wavelength. Giant pulses were obtained with both passive Q-switches. When V:YAG saturable absorber was used, 55 ns long (FWHM) pulses were generated with peak power 0.47kW (pulse energy 26 μJ). Using Co:MALO, more powerful pulses were obtained (40 ns long, 1.0kW peak power, 45 μJ energy). Advantage of less efficient V:YAG consist in possibility of diffusion bonding between Q-switch and laser active medium which allows to prepare miniature compact laser device. This concept was demonstrated by using of Nd:YAG/V:YAG monolith crystal (4mm long undoped YAG part, 8mm long Nd:YAG part, 0.5mm long V:YAG part - initial transmission 97% @ 1444 nm). This monolithic crystal, originally designed for 1338nm lasing, was placed into 23mm long cavity resonating at wavelength 1444 nm. For output coupler reflectivity 96% pulses 39 ns long with peak power 0.64kW were generated at wavelength 1444 nm.

  17. Comparison between Er:YAG laser and bipolar radiofrequency combined with infrared diode laser for the treatment of acne scars: Differential expression of fibrogenetic biomolecules may be associated with differences in efficacy between ablative and non-ablative laser treatment.

    PubMed

    Min, Seonguk; Park, Seon Yong; Moon, Jungyoon; Kwon, Hyuck Hoon; Yoon, Ji Young; Suh, Dae Hun

    2017-04-01

    Fractional Er:YAG minimizes the risk associated with skin ablation. Infrared diode laser and radiofrequency have suggested comparable improvements in acne scar. We compared the clinical efficacy of Er:YAG laser and bipolar radiofrequency combined with diode laser (BRDL) for the treatment of acne scars. Moreover, acute molecular changes of cytokine profile associated with wound healing have been evaluated to suggest mechanisms of improvement of acne scar. Twenty-four subjects with mild-to-moderate acne scars were treated in a split-face manner with Er:YAG and BRDL, with two treatment sessions, 4 weeks apart. Objective and subjective assessments were done at baseline, 1, 3, 7 days after each treatment and 4 weeks after last treatment. Skin biopsy specimens were obtained at baseline, 1, 3, 7, 28 days after one session of treatment for investigation of molecular profile of acute skin changes by laser treatment. Investigator's Global Assessment representing the improvement degree shows 2.1 (50%) in fractional Er:YAG and 1.2 (25%) in BRDL. Er:YAG induced the later and higher peak expression of TGFβs and collagenases, whereas BRDL induced earlier and lower expression of TGFβ and collagenases, relatively. PPARγ dropped rapidly after a peak in Er:YAG-treated side, which is associated with tissue inhibitor of metalloproteinase (TIMP) expression. We observed higher expression of TIMP after Er:YAG treatment compared with BRDL by immunohistochemistry, which may be associated with the expression of upregulation of collagen fibers. The superior efficacy of Er:YAG to BRDL in the treatment of acne scars may be associated with higher expression of collagen which is associated with differential expression of TGFβs, collagenases, PPARγ, and TIMP. Lasers Surg. Med. 49:341-347, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Use of a microsecond Er:YAG laser in laryngeal surgery reduces collateral thermal injury in comparison to superpulsed CO2 laser.

    PubMed

    Böttcher, Arne; Jowett, Nathan; Kucher, Stanislav; Reimer, Rudolph; Schumacher, Udo; Knecht, Rainald; Wöllmer, Wolfgang; Münscher, Adrian; Dalchow, Carsten V

    2014-05-01

    Despite causing significant thermocoagulative insult, use of the carbon dioxide (CO2) laser is considered gold standard in surgery for early stage larynx carcinoma. Limited attention has been paid to the use of the erbium:yttrium-aluminium-garnet (Er:YAG) laser in laryngeal surgery as a means to reduce thermal tissue injury. The objective of this study is to compare the extent of thermal injury and precision of vocal fold incisions made using microsecond Er:YAG and superpulsed CO2 lasers. In the optics laboratory ex vivo porcine vocal folds were incised using Er:YAG and CO2 lasers. Lateral epithelial and subepithelial thermal damage zones and cutting gap widths were histologically determined. Environmental scanning electron microscopy (ESEM) images were examined for signs of carbonization. Temperature rise during Er:YAG laser incisions was determined using infrared thermography (IRT). In comparison to the CO2 laser, Er:YAG laser incisions showed significantly decreased epithelial (236.44 μm) and subepithelial (72.91 μm) damage zones (p < 0.001). Cutting gaps were significantly narrower for CO2 (878.72 μm) compared to Er:YAG (1090.78 μm; p = 0.027) laser. ESEM revealed intact collagen fibres along Er:YAG laser cutting edges without obvious carbonization, in comparison to diffuse carbonization and tissue melting seen for CO2 laser incisions. IRT demonstrated absolute temperature rise below 70 °C for Er:YAG laser incisions. This study has demonstrated significantly reduced lateral thermal damage zones with wider basal cutting gaps for vocal fold incisions made using Er:YAG laser in comparison to those made using CO2 laser.

  19. Crystal growth, structural, optical, thermal, mechanical, laser damage threshold and electrical properties of triphenylphosphine oxide 4-nitrophenol (TP4N) single crystals for nonlinear optical applications

    NASA Astrophysics Data System (ADS)

    Karuppasamy, P.; Senthil Pandian, Muthu; Ramasamy, P.; Verma, Sunil

    2018-05-01

    The optically good quality single crystals of triphenylphosphine oxide 4-nitrophenol (TP4N) with maximum dimension of 15 × 10 × 5 mm3 were grown by slow evaporation solution technique (SEST) at room temperature. The cell dimensions of the grown TP4N crystal were confirmed by single crystal X-ray diffraction (SXRD) and the crystalline purity was confirmed and planes were indexed by powder X-ray diffraction (PXRD) analysis. Functional groups of TP4N crystal were confirmed by Fourier transform infrared (FTIR) spectral analysis. The optical transmittance of the grown crystal was determined by the UV-Vis NIR spectral analysis and it has good optical transparency in the entire visible region. The band tail (Urbach) energy of the grown crystal was analyzed and it appears to be minimum, which indicates that the TP4N has good crystallinity. The position of valence band (Ev) and conduction band (Ec) of the TP4N have been determined from the electron affinity energy (EA) and the ionization energy (EI) of its elements and using the optical band gap. The thermal behaviour of the grown crystal was investigated by thermogravimetric and differential thermal analysis (TG-DTA). Vickers microhardness analysis was carried out to identify the mechanical stability of the grown crystal and their indentation size effect (ISE) was explained by the Meyer's law (ML), Hays-Kendall's (HK) approach, proportional specimen resistance (PSR) model, modified PSR model (MPSR), elastic/plastic deformation (EPD) model and indentation induced cracking (IIC) model. Chemical etching study was carried out to find the etch pit density (EPD) of the grown crystal. Laser damage threshold (LDT) value was measured by using Nd:YAG laser (1064 nm). The dielectric permittivity (ε՛) and dielectric loss (tan δ) as a function of frequency was measured. The electronic polarizability (α) of the TP4N crystal was calculated. It is well matched to the value which was calculated from Clausius-Mossotti relation

  20. Investigation of angular dependence on photonic bandgap for 1-D photonic crystal

    NASA Astrophysics Data System (ADS)

    Nigam, Anjali; Suthar, B.; Bhargava, A.; Vijay, Y. K.

    2018-05-01

    In the present communication, we study the one-dimensional photonic crystal structure. The photonic band structure has been obtained using Plane Wave Expansion Method (PWEM). The studied has been extended to investigate the angular dependence on photonic bandgap for 1-D photonic crystal. The photonic bandgap is same both for TE and TM mode for normal incidence, while both mode move separate with an incidence angle. The photonic bandgap is almost unaffected with angle for TE mode while the bandgap decreases with an incidence angle for TM mode.

  1. Growth, structural, spectroscopic, thermal, dielectric and optical study of cobalt sulphide-doped ADP crystals

    NASA Astrophysics Data System (ADS)

    Kochuparampil, A. P.; Joshi, J. H.; Joshi, M. J.

    2017-09-01

    As ammonium dihydrogen phosphate (ADP) is a popular nonlinear optical crystal, to engineer its linear and nonlinear optical properties, the chalcogenide compound cobalt sulphide (CoS) was doped and the crystals were grown by the slow solvent evaporation method. To increase the solubility of CoS in water, its nanoparticles were synthesized by wet chemical technique using ethylene diamine as the capping agent followed by microwave irradiation. The nanoparticle sample exhibited finite solubility in water and was used to dope in ADP crystals. The powder XRD patterns showed the single phase nature of the doped crystals. The FTIR spectra confirmed the presence of various functional groups and EDAX gave the estimation of Co and S elements. The EPR spectroscopy also confirmed the presence of cobalt in the doped samples. TGA indicated slightly less thermal stability of the doped crystals compared to the pure ADP. The dielectric study was carried out at room temperature in the frequency range from 100Hz to 1MHz. Also, various linear optical parameters were evaluated for pure and doped crystals using UV-Vis spectroscopy. The second harmonic generation (SHG) efficiency of Nd:YAG laser was evaluated by the Kurtz and Parry method for the doped samples, it was found to be slightly lesser than that of the pure ADP crystals.

  2. Use of the Er:YAG laser for improved plating in maxillofacial surgery: comparison of bone healing in laser and drill osteotomies.

    PubMed

    Lewandrowski, K U; Lorente, C; Schomacker, K T; Flotte, T J; Wilkes, J W; Deutsch, T F

    1996-01-01

    Surgical reconstruction of bony defects in the maxillofacial region involves fixation of bony fragments with mini and micro plates. Bone stabilization during hole drilling is often challenging due to the need to apply pressure when using a conventional mechanical Hall drill. In addition, fragmentation of the fragile bones may occur and complicate the reconstruction. The pulsed Er:YAG laser offers an attractive alternative drilling modality because it does not require physical contact with the bone in order to drill holes, cuts bone with minimal thermal damage, and allows precise control of bone cutting. The objective of this study was to investigate the pulsed Er:YAG laser as an alternative to the mechanical bur by comparing bone healing using both modalities. Bone healing in an inferior border defect of the rat mandible was examined using either an Er:YAG laser or a mechanical bur for drilling. The healing of osteotomies in facial bones and of screw holes for plate stabilization of free bone fragments was studied. All defects healed by 4 weeks postoperatively. Histologic evaluation demonstrated no difference in the amount of newly formed woven bone at the osteotomy site or screw holes made by either the laser or the drill. The extent of thermal damage at the osteotomy sites was comparable in laser and mechanically cut bone fragments. On the basis of this study we suggest that the Er: YAG laser can be used clinically in thin, fragile bones in the maxillofacial region.

  3. HOMO-LUMO analysis of multi walled carbon nanotubes doped Tetrafluoro Phthalate crystals for nonlinear optical applications

    NASA Astrophysics Data System (ADS)

    Latha, B.; Kumaresan, P.; Nithiyanantham, S.; Sampathkumar, K.

    2018-01-01

    The MWCNTs doped Tetrafluoro Phthalate (C6H2F4O4) precious stones are constantly having higher transmission rate contrasted with immaculate Tetrafluoro Phthalate crystal. The dependability of Tetrafluoro Phthalate crystal was enhanced by doping MWCNTs.The basic, synthetic, optical, mechanical and non-direct optical properties of the doped precious crystals were dissected with the portrayal concentrates, for example, powder XRD, FT-IR, UV-Visible, Hardness and SHG estimations individually. The dopants are relied upon to substitute the carbon iotas in the Tetrafluoro Phthalate grid because of their change of valency and in addition vicinity of ionic sweep. The strength and charge delocalization of the particle were additionally concentrated on by characteristic security orbital (NBO) examination. The HOMO-LUMO energies depict the charge exchange happens inside the atom. Atomic electrostatic potential has been dissected. The SHG productivity of the immaculate and colors doped TFP crystals were additionally contemplated utilizing Nd:YAG Q-exchanged laser.

  4. Very unusual "needle- and pencil-like" uric acid crystals in the urine unmasked by infrared spectroscopy investigation.

    PubMed

    Baroni, S; Garigali, G; Primiano, A; Gervasoni, J; Fogazzi, G B

    2018-04-01

    In this paper we describe a case with very unusual "needle- and pencil-like" crystals, partly similar to those reported by other investigators, who considered them as due to uric acid. Quite importantly, infrared spectroscopy investigation which, to our knowledge, we have been the first to perform on this type of crystals, confirmed their nature as uric acid structures. This case demonstrates that the planet of urinary crystals still has several unknown facets and still deserves exploration. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Controlled In Meso Phase Crystallization – A Method for the Structural Investigation of Membrane Proteins

    PubMed Central

    Kubicek, Jan; Schlesinger, Ramona; Baeken, Christian; Büldt, Georg; Schäfer, Frank; Labahn, Jörg

    2012-01-01

    We investigated in meso crystallization of membrane proteins to develop a fast screening technology which combines features of the well established classical vapor diffusion experiment with the batch meso phase crystallization, but without premixing of protein and monoolein. It inherits the advantages of both methods, namely (i) the stabilization of membrane proteins in the meso phase, (ii) the control of hydration level and additive concentration by vapor diffusion. The new technology (iii) significantly simplifies in meso crystallization experiments and allows the use of standard liquid handling robots suitable for 96 well formats. CIMP crystallization furthermore allows (iv) direct monitoring of phase transformation and crystallization events. Bacteriorhodopsin (BR) crystals of high quality and diffraction up to 1.3 Å resolution have been obtained in this approach. CIMP and the developed consumables and protocols have been successfully applied to obtain crystals of sensory rhodopsin II (SRII) from Halobacterium salinarum for the first time. PMID:22536388

  6. Nd:(Gd0.3Y0.7)2SiO5 crystal: A novel efficient dual-wavelength continuous-wave medium

    NASA Astrophysics Data System (ADS)

    Xu, Xiaodong; Di, Juqing; Zhang, Jian; Tang, Dingyuan; Xu, Jun

    2016-05-01

    Efficient dual-wavelength continuous-wave (CW) and passively Q-switched laser operation of Nd:(Gd0.3Y0.7)2SiO5 crystal were investigated for the first time to our knowledge. Maximum CW output power of 2.3 W was obtained under the absorbed pump power of 4.6 W, corresponding to the slope efficiency of 55%. Dual-wavelength CW laser with respective wavelengths around 1074 nm and 1078 nm were achieved. With Cr4+:YAG as the saturable absorber, passive Q-switched performance was obtained. The slope efficiency of passively Q-switched operation was 45%. The shortest pulse width, the corresponding pulse energy and peak power were calculated to be 13.1 ns, 50.2 μJ and 3.8 kW, respectively.

  7. Fractured Anterior Chamber Intraocular Lens (ACIOL) Complicating Nd: YAG Laser for Peripheral Iridotomy.

    PubMed

    Farah, Edgard; Koutsandrea, Chryssanthi; Papaefthimiou, Ioannis; Papaconstantinou, Dimitris; Georgalas, Ilias

    2013-01-01

    Laser peripheral iridotomy is the procedure of choice for the treatment of angle-closure glaucoma caused by relative or absolute pupillary block. Nd: YAG laser iridotomy has been reported to have several complications such as Iris bleeding, hyphema, transient IOP elevation, intraocular inflammation, choroidal, retinal detachment and vitreous hemorrhage. We report a case of a 74 year old lady on anticoagulant treatment who developed pupillary block and angle closure glaucoma after cataract surgery and anterior chamber intraocular lens (ACIOL) insertion complicated with intraoperative bleeding. The patient was treated with Nd: YAG laser iridotomy , however, the ACIOL was inadvertently fractured after a single shot of laser and it had to be replaced. Although the incidence is rare. Ophthalmologists and Opticians should be aware that an ACIOL may be fractured even after a single Nd:YAG laser shot and avoid to perform it close to the ACIOL. Pretreatment counseling should include this rare complication.

  8. Using transurethral Ho:YAG-laser resection to treat urethral stricture and bladder neck contracture

    NASA Astrophysics Data System (ADS)

    Bo, Juanjie; Dai, Shengguo; Huang, Xuyuan; Zhu, Jing; Zhang, Huiguo; Shi, Hongmin

    2005-07-01

    Objective: Ho:YAG laser had been used to treat the common diseases of urinary system such as bladder cancer and benign prostatic hyperplasia in our hospital. This study is to assess the efficacy and safety of transurethral Ho:YAG-laser resection to treat the urethral stricture and bladder neck contracture. Methods: From May 1997 to August 2004, 26 cases of urethral stricture and 33 cases of bladder neck contracture were treated by transurethral Ho:YAG-laser resection. These patients were followed up at regular intervals after operation. The uroflow rate of these patients was detected before and one-month after operation. The blood loss and the energy consumption of holmium-laser during the operation as well as the complications and curative effect after operation were observed. Results: The therapeutic effects were considered successful, with less bleeding and no severe complications. The Qmax of one month postoperation increased obviously than that of preoperation. Of the 59 cases, restenosis appeared in 11 cases (19%) with the symptoms of dysuria and weak urinary stream in 3-24 months respectively. Conclusions: The Ho:YAG-laser demonstrated good effect to treat the obstructive diseases of lower urinary tract such as urethral stricture and bladder neck contracture. It was safe, minimal invasive and easy to operate.

  9. A new procedure for refurbishment of power plant Superalloy 617 by pulsed Nd:YAG laser process

    NASA Astrophysics Data System (ADS)

    Taheri, Naser; Naffakh-Moosavy, Homam; Ghaini, Farshid Malek

    2017-06-01

    The present study has evaluated the surface rejuvenation of aged Inconel 617 superalloy by both GTAW and pulsed Nd:YAG laser techniques. The gas tungsten arc welding (GTAW) by heat input per unit length [Q/V(J/mm)] of 280, 291.67, 309.74 and 225.48 (J/mm), and the pulse Nd:YAG laser process by the 15.71, 19.43 and 22.32 (J/mm), were employed. The Rosenthal equation was used for calculation of mushy zone (MZ) and partially-melted zone (PMZ). Size of MZ and PMZ in GTAW are more than 31 and 6 times than that of formed in pulsed Nd:YAG laser. According to the characterizations, solidification and liquation cracks were observed in these areas produced by GTAW whereas no cracks were identified in laser treated samples. Also, line scan EDS analyses demonstrated the interdendritic chromium and molybdenum segregation, which facilitated formation of hot cracks. With reduction in heat input per unit length, the hardness increased and the size of solidified metal microstructure reduced in pulse Nd:YAG laser. These comparative results showed that pulse Nd:YAG laser can easily be utilized as a new rejuvenation technique for aged Alloy 617 in comparison to the conventional processes due to extremely narrow MZ and HAZ and better surface soundness and mechanical properties.

  10. Er:YAG and alexandrite laser radiation propagation in the root canal and its effect on bacteria

    NASA Astrophysics Data System (ADS)

    Jelinkova, Helena; Dostalova, Tatjana; Duskova, Jana; Miyagi, Mitsunobu; Shoji, Shigeru; Sulc, Jan; Nemec, Michal

    1999-05-01

    The goal of the study was to verify differences between the alexandrite and Er:YAG laser energy distribution in the root canal and in the surrounding dentin and bone tissues. For the experiment, two lasers were prepared: the Er:YAG laser (λ=2.94 μm) with a delivery system fluorocarbon polymer-coated silver hollow glass waveguide ended by a special sapphire tip and the alexandrite laser (λ=0.75 μm) with a silicon fiber. The Er:YAG laser was operated in a free-running mode, the length of the generated pulses was 250 μsec and the output energy ranged from 100 to 350 mJ. The pulse length of the free- running alexandrite laser was 70 μsec and the output energy was ranged from 80 up to 200 mJ. For the experiment prepared root canals of molars were used. It was ascertained that the radiation of the alexandrite laser passes through the root canal and hits the surrounding tissue. Nocardia asteroids, Filaments, Micrococcus albus, Lactobacillus sp and Streptococcus sanguis colonies were treated by the Er:YAG or alexandrite laser radiation. The surface was checked by scanning electron microscopy. From the result it follows that the Er:YAG laser destroyed microbial colonies but the differences is in the depth of the affected area.

  11. A solar-pumped Nd:YAG laser in the high collection efficiency regime

    NASA Astrophysics Data System (ADS)

    Lando, Mordechai; Kagan, Jacob; Linyekin, Boris; Dobrusin, Vadim

    2003-07-01

    Solar-pumped lasers can be used for space and terrestrial applications. We report on solar side-pumped Nd:YAG laser experiments, which included comprehensive beam quality measurements and demonstrated record collection efficiency and day long operation. A 6.75 m 2 segmented primary mirror was mounted on a commercial two-axis positioner and focused the solar radiation towards a stationary non-imaging-optics secondary concentrator, which illuminated a Nd:YAG laser rod. Solar side-pumped laser experiments were conducted in both the low and the high pumping density regimes. The low density system was composed of a 89 × 98-mm 2 aperture two-dimensional compound parabolic concentrator (CPC) and a 10-mm diameter 130-mm long Nd:YAG laser rod. The laser emitted up to 46 W and operated continuously for 5 h. The high density system was composed of a three-dimensional CPC with 98 mm entrance diameter and 24 mm exit diameter, followed by a two-dimensional CPC with a rectangular 24 × 33 mm 2 aperture. It pumped a 6-mm diameter 72 mm long Nd:YAG laser rod, which emitted up to 45 W. The results constitute a record collection efficiency of 6.7 W/m 2 of primary mirror. We compare the current results to previous solar side-pumped laser experiments, including experiments at higher pumping density but with low collection efficiency. Finally, we present a scaled up design for a 400 W laser pumped by a solar collection area of 60 m 2, incorporating simultaneously high collection efficiency and high pumping density.

  12. Clinical dental application of Er:YAG laser for Class V cavity preparation.

    PubMed

    Matsumoto, K; Nakamura, Y; Mazeki, K; Kimura, Y

    1996-06-01

    Following the development of the ruby laser by Maiman in 1960, the Nd:YAG laser, the CO2 laser, the semiconductor laser, the He-Ne laser, excimer lasers, the argon laser, and finally the Er:YAG laser capable of cutting hard tissue easily were developed and have come to be applied clinically. In the present study, the Er:YAG laser emitting at a wavelength of 2.94 microns developed by Luxar was used for the clinical preparation of class V cavities. Parameters of 8 Hz and approx. 250 mJ/pulse maximum output were used for irradiation. Sixty teeth of 40 patients were used in this clinical study. The Er:YAG laser used in this study was found to be a system suitable for clinical application. No adverse reaction was observed in any of the cases. Class V cavity preparation was performed without inducing any pain in 48/60 cases (80%). All of the 12 cases that complained of mild or severe intraoperative pain had previously complained of cervical dentin hypersensibility during the preoperative examination. Cavity preparation was completed with this laser system in 58/60 cases (91.7%). No treatment-related clinical problems were observed during the follow-up period of approx. 30 days after cavity preparation and resin filling. Cavity preparation took between approx. 10 sec and 3 min and was related more or less to cavity size and depth. Overall clinical evaluation showed no safety problem with very good rating in 49 cases (81.7%).

  13. New application of a bipolar Nd:YAG handpiece in laser cardiac surgery

    NASA Astrophysics Data System (ADS)

    Mizutani, Tetsuo; Suzuki, Hitoshi; Katayama, Yoshihiko

    1997-05-01

    A bipolar Nd-YAG laser (1.064 micrometer) handpiece was experimentally examined for a venous dissection without scissors and sutures and clinically introduced for the vein graft harvesting in coronary artery bypass grafting (CABG). Experimental study: One hundred and thirty-five segments of the mongrel dog veins were employed. Nd-YAG laser was irradiated on the vein held by the bipolar Nd-YAG handpiece at the power of 5, 9, 13, and 17 watts, and success defined as a complete vein citing without bleeding at the laser-applied sites were gained in all except three; 97.8% of success rate. Laser exposure time for cutting the vein decreased in order to an increase of the applied laser power, and the veins of bigger diameter needed more longer exposure time in the group of the same laser power. An average exposure time was 4.4 seconds for the veins of 1 mm diameter at 13 watts. In histological examination, a vascular lumen at the cutting site was diminished and covered with a degenerated vascular wall, and bleeding was not seen in all specimen. Clinical study: In 18 cases of CABG the bipolar Nd-YAG handpiece was applied to cut the branches of the great saphenous vein without scissors and sutures. Forty-two grafts harvested by this handpiece were used for aortocoronary bypass grating. All were survived and the angiographic examination demonstrated a 90% of graft patency at an average period of 3.5 years after the operation. Laser-induced morphological change such as aneurysmal formation or graft stenosis was not recognized.

  14. 1645-nm single-frequency, injection-seeded Q-switched Er:YAG master oscillator and power amplifier

    NASA Astrophysics Data System (ADS)

    Wang, Shuo; Gao, Chunqing; Shi, Yang; Song, Rui; Na, Quanxin; Gao, Mingwei; Wang, Qing

    2018-02-01

    A 1645-nm injection-seeded Q-switched Er:YAG master oscillator and power amplifier system is reported. The master oscillator generates single-frequency pulse energy of 11.10 mJ with a pulse width of 188.8 ns at 200 Hz. An Er:YAG monolithic nonplanar ring oscillator is employed as a seed laser. The output pulse from the master oscillator is amplified to 14.33-mJ pulse energy through an Er:YAG amplifier, with a pulse width of 183.3 ns. The M2-factors behind the amplifier are 1.14 and 1.23 in x- and y-directions, respectively. The full width at half maximum of the fast Fourier transformation spectrum of the heterodyne beating signal is 2.84 MHz.

  15. Simulation of medical Q-switch flash-pumped Er:YAG laser

    NASA Astrophysics Data System (ADS)

    -Yan-lin, Wang; Huang-Chuyun; Yao-Yucheng; Xiaolin, Zou

    2011-01-01

    Er: YAG laser, the wavelength is 2940nm, can be absorbed strongly by water. The absorption coefficient is as high as 13000 cm-1. As the water strong absorption, Erbium laser can bring shallow penetration depth and smaller surrounding tissue injury in most soft tissue and hard tissue. At the same time, the interaction between 2940nm radiation and biological tissue saturated with water is equivalent to instantaneous heating within limited volume, thus resulting in the phenomenon of micro-explosion to removal organization. Different parameters can be set up to cut enamel, dentin, caries and soft tissue. For the development and optimization of laser system, it is a practical choice to use laser modeling to predict the influence of various parameters for laser performance. Aim at the status of low Erbium laser output power, flash-pumped Er: YAG laser performance was simulated to obtain optical output in theory. the rate equation model was obtained and used to predict the change of population densities in various manifolds and use the technology of Q-switch the simulate laser output for different design parameters and results showed that Er: YAG laser output energy can achieve the maximum average output power of 9.8W under the given parameters. The model can be used to find the potential laser systems that meet application requirements.

  16. Effect of neodymium:YAG laser capsulotomy on visual function in patients with posterior capsule opacification and good visual acuity.

    PubMed

    Yotsukura, Erisa; Torii, Hidemasa; Saiki, Megumi; Negishi, Kazuno; Tsubota, Kazuo

    2016-03-01

    To evaluate the effect of neodymium:YAG (Nd:YAG) laser capsulotomy on the visual function in patients with posterior capsule opacification (PCO) and good visual acuity. Keio University Hospital, Tokyo, Japan. Observational case series. Eyes were evaluated that had previous cataract surgery with a clinical diagnosis of PCO requiring Nd:YAG laser capsulotomy regardless of a good corrected distance visual acuity (CDVA) (at least 20/20). The CDVA, 10% low contrast visual acuity (LCVA), wavefront aberrations from the 3rd to 6th order, and retinal straylight were measured before and after Nd:YAG laser capsulotomy. The study included 16 eyes of 16 patients (10 men, 6 women; mean age 69.5 years ± 9.3 [SD]). The mean CDVA, LCVA, and straylight after Nd:YAG laser capsulotomy improved significantly (P < .05). The root mean square (RMS) of the 3rd Zernike coefficients (S3) and the RMS of the total higher-order aberrations (HOAs) from the 3rd to 6th order decreased significantly after capsulotomy (P < .05). The straylight correlated significantly with the total HOAs (r = 0.727, P = .002) and S3 (r = 0.748, P = .001) before capsulotomy. Subjective symptoms resolved after capsulotomy in all cases. Neodymium:YAG laser capsulotomy enabled a significant improvement in visual function even in patients with PCO with good visual acuity. Straylight measurements might be useful to determine the indications for Nd:YAG laser capsulotomy when patients report visual disturbances without decreased visual acuity. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Urological applications of Ho/Nd:Yag laser

    NASA Astrophysics Data System (ADS)

    Grifoni, Riccardo; Pierangeli, Tiziana; Gioacchini, Andrea; Muraro, Giovanni B.

    2001-10-01

    The introduction of Ho:Yag laser has brought many advantages in urology. By this work we want show you our experience with this technology. Between April 1998 and May 2000 we treated 137 patients. Of these 28 had urinary lithiasis (18 bladder and 10 ureteral stones 3 in the upper, 2 in the middle and 5 in the distal tract), 40 were affected by enlargement of prostatic gland: 32 had B.P.H., 8 P.C.; 36 had T.C.C. and 33 strictures of urethra (27) or bladder neck (6). For ureteral lithiasis we used 200 micrometer fiber, energy of 0.5 - 1.4 J with 10 Hz of frequency. In case of bladder stones a 550 or 1000 micrometer using a power of 80 W. The prostatic gland were resected by a 550 micrometer fiber, 2.2 - 2.8 J, 25 - 30 Hz and 70 -80 W. The superficial bladder tumors were removed by 1.4 J with 10 - 15 Hz and 10 - 14 W. In the large tumors we completed the procedure by Nd:YAG at the base of the tumor. Urethra and bladder neck strictures were treated by 1.2 - 1.8 J and 10 - 30 Hz. We successful treated 26 patients with urinary lithiasis obtained the complete vaporization of the stones, 2 had endoscopic ancillary procedures. Out of 32 patients with B.P.H. 41% had the complete resection of the gland the others the resection of the 3d lobe. We removed 114 superficial bladder tumors and only 4 patients had a local recurrence. Of the patients with the strictures 4 had more than one treatment and about 87% had good result. From our experience the use of Holmium:Yag laser has been very efficacy to treat different urological diseases, also in patients with important comorbid disorders and its use reduce the stay in hospital and so the costs.

  18. Nd:YAG Pulsed Laser Assisted Machining of AMS 5708 Waspaloy Alloy

    NASA Astrophysics Data System (ADS)

    Sharifi, Zahra; Shoja-Razavi, Reza; Vafaei, Reza; Hashemi, Sayed Hamid

    2018-03-01

    Due to very high strenght, low thermal conductivity, and high work hardening rate, the machinability of nickel-based superalloys is poor at room temperature. Laser-assisted machining (LAM) can provide a better aspect of machining such alloys. Since the wavelength of Nd:YAG laser is about 1/10th of that of CO2 laser, absorption and heating efficiency of Nd:YAG laser is much higher on metals and especially superalloys. Transmission of Nd:YAG laser through fiber optics to the heating point on the workpiece is a simple task during machining. This makes the LAM process more convenient and practical than the CM process. In this study a model is introduced for LAM of waspaloy, and its machinability is evaluated in terms of ease of material removal. Also, a temperature generation model is introduced for the Nd:YAG laser beam. Furthemore, wear behavior of an uncoated tungsten carbide and the formed chips were compared during the LAM and the CM of waspolay. To study the wear mechanism, the worn cutting tool was studied via scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS). The formed chips were also evaluated via SEM and optical microscopy. Based on the results, the optimum LAM conditions were obtained at a cutting speed of 24 m/min and a feed rate of 0.06 mm/rev when a 400 W laser mean power and 80 Hz frequency are applied. Under these conditions, the temperature ahead of the cutting tool edge on the surface of workpiece was estimated to be 524°C. In comparison with CM, a significant improvement in tool wear and a better chip morphology were achieved through LAM, and also specific cutting energy and surface roughness were reduced by 25 and 20%, respectively.

  19. Investigation of crystal growth in zero gravity environment and investigation of metallic whiskers

    NASA Technical Reports Server (NTRS)

    Davis, J. H.; Lal, R. B.; Walter, H. U.; Castle, J. G., Jr.

    1972-01-01

    Theoretical and experimental work reported relates to the effects of near-zero gravity on growths of crystals and metallic whiskers during Skylab and Apollo flight experiments. Studies on growth and characterization of candidate materials for flight experiments cover indium-bismuth compounds, bismuth single crystals, gallium arsenide films and single crystals, and cadmium whiskers.

  20. Growth, structural, optical, thermal and laser damage threshold studies of an organic single crystal: 1,3,5 – triphenylbenzene (TPB)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raja, R. Subramaniyan; Babu, G. Anandha; Ramasamy, P., E-mail: E-mail-ramasamyp@ssn.edu.in

    2016-05-23

    Good quality single crystals of pure hydrocarbon 1,3,5-Triphenylbenzene (TPB) have been successfully grown using toluene as a solvent using controlled slow cooling solution growth technique. TPB crystallizes in orthorhombic structure with the space group Pna2{sub 1}. The structural perfection of the grown crystal has been analysed by high resolution X-ray diffraction measurements. The range and percentage of the optical transmission are ascertained by recording the UV-vis spectrum. Thermo gravimetric analysis (TGA) and differential thermal analysis (DTA) were used to study its thermal properties. Powder second harmonic generation studies were carried out to explore its NLO properties. Laser damage threshold valuemore » has been determined using Nd:YAG laser operating at 1064 nm.« less

  1. [Comparison of validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy].

    PubMed

    Bi, Sheng; Xia, Ming

    2015-08-11

    To compare the validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy. A total of 28 patients were divided into two groups (holmium: YAG laser group without renal artery clamping and traditional surgery group with renal artery clamping). The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were recorded. The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were 80 ml, 77 min, 0 min, 7.4 days, 35 ml/min, 0, 0.9 cm, respectively, in holmium: YAG laser group. And in traditional surgery group were 69 ml, 111 min, 25.5 min, 7.3 days, 34 ml/min, 0, 2.0 cm, respectively. The differences of total operative time, renal artery clamping time and depth of tissue injury between two groups were statistically significant. The others were not statistically significant. Holmium: YAG laser is effective and safe in partial nephrectomy. It can decrease the total operative time, minimize the warm ischemia time and enlarge the extent of surgical excision.

  2. Chromium Recharging Processes in the Y3Al5O12: Mg, Cr Single Crystal under the Reducing and Oxidizing Annealing Influence

    DTIC Science & Technology

    2001-01-01

    approximately 0.2% of total number of chromium ions occupied tetrahedral sites forming phototropic centers in the YAG: Mg, Cr crystal. Keywords: yttrium...aluminium garnet, Cr doping, thermal treatment, phototropic centers, optical characterization, electron paramagnetic resonance. 1. INTRODUCTION An...of garnet structure while the main part of chromium occupies octahedral sites in three-valence state. 10-12 The dependence of amount of phototropic

  3. Transmission of Er:YAG laser through different dental ceramics.

    PubMed

    Sari, Tugrul; Tuncel, Ilkin; Usumez, Aslihan; Gutknecht, Norbert

    2014-01-01

    The aim of this study was to determine the erbium-doped yttrium aluminum garnet (Er:YAG) laser transmission ratio through different dental ceramics with different thicknesses. Laser debonding procedure of adhesively luted all-ceramic restorations is based on the transmission of laser energy through the ceramic and the ablation of resin cement, because of the transmitted laser energy. Five different dental ceramics were evaluated in this study: sintered zirconium-oxide core ceramic, monolithic zirconium-oxide ceramic, feldspathic ceramic, leucite-reinforced glass ceramic, and lithium disilicate-reinforced glass ceramic. Two ceramic discs with different thicknesses (0.5 and 1 mm) were fabricated for each group. Ceramic discs were placed between the sensor membrane of the laser power meter and the tip of the contact handpiece of an Er:YAG laser device with the aid of a custom- made acrylic holder. The transmission ratio of Er:YAG laser energy (500 mJ, 2 Hz, 1 W, 1000 μs) through different ceramic discs was measured with the power meter. Ten measurements were made for each group and the results were analyzed with two way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests. The highest transmission ratio was determined for lithium disilicate-reinforced ceramic with 0.5 mm thickness (88%) and the lowest was determined for feldspathic ceramic with 1 mm thickness (44%). The differences among the different ceramics and between the different thicknesses were significant (p<0.05). Ceramic type and thickness should be taken into consideration to adjust the laser irradiation parameters during laser debonding of adhesively luted all-ceramic restorations.

  4. Highly efficient continuous-wave Nd:YAG ceramic lasers at 946 nm

    NASA Astrophysics Data System (ADS)

    Zhu, H. Y.; Xu, C. W.; Zhang, J.; Tang, D. Y.; Luo, D. W.; Duan, Y. M.

    2013-07-01

    Highly efficient CW operation of diode-end-pumped Nd:YAG ceramic lasers at 946 nm is experimentally demonstrated. When a 5 mm long in-house fabricated Nd:YAG ceramic was used as the gain medium, a maximum output power of 10.5 W was obtained under an incident pump power of 35 W, corresponding to an optical conversion efficiency of 30%, while, when a 3 mm long ceramic sample was used, a maximum output power of 8.7 W was generated with a slope efficiency of 65% with respect to the absorbed pump power. Both the optical conversion efficiency and slope efficiency are the highest results reported so far for the diode-pumped 946 nm lasers.

  5. Design of a high-power, high-brightness Nd:YAG solar laser.

    PubMed

    Liang, Dawei; Almeida, Joana; Garcia, Dário

    2014-03-20

    A simple high-power, high-brightness Nd:YAG solar laser pumping approach is presented in this paper. The incoming solar radiation is both collected and concentrated by four Fresnel lenses and redirected toward a Nd:YAG laser head by four plane-folding mirrors. A fused-silica secondary concentrator is used to compress the highly concentrated solar radiation to a laser rod. Optimum pumping conditions and laser resonator parameters are found through ZEMAX and LASCAD numerical analysis. Solar laser power of 96 W is numerically calculated, corresponding to the collection efficiency of 24  W/m². A record-high solar laser beam brightness figure of merit of 9.6 W is numerically achieved.

  6. Enhancement of light absorption by blood to Nd:YAG laser using PEG-modified gold nanorods.

    PubMed

    Xing, Linzhuang; Li, Dong; Chen, Bin; Dai, Yuze; Wu, Wenjuan; Wang, Guoxiang

    2016-10-01

    On the basis of the principle of selective photothermolysis, laser therapy has been the most effective treatment strategy for Port-wine stains (PWSs) caused by the expansion of dermal capillaries. Neodymium:Yttrium Aluminum Garnet (Nd:YAG) laser at 1064 nm wavelength has great potential for deeply buried PWS, although its application is limited because of its weak absorption by blood. The purpose of this study is to investigate the effect of PEG-modified gold nanorods (NRs) on the blood absorption enhancement for Nd:YAG laser. PEG-modified gold nanorods (NRs) were synthesized via the seeded growth method. Then, the effect of PEG-modified gold NRs on blood light absorbance was investigated through adding different concentration of PEG-modified gold NRs to 1 ml of blood at room temperature. Finally, the optical properties of whole mice blood with or without PEG-modified gold NRs under slow heating were investigated. The average length and width of PEG-modified gold NRs are 79.5 ± 10.5 and 13.5 ± 0.9 nm, respectively, with the aspect ratio of 5.89, and a strong absorption peak exists at ∼1050 nm in the near-infrared range. A linear correlation between the blood absorbance at 1064 nm and the amount of PEG-modified gold NRs was obtained. The absorbance at 1064 nm increased 17.6, 33.0, 48.3, and 65.4 times when 0.4, 0.8, 1.2, and 1.6 mg of PEG-modified gold NRs was added to 1 ml of blood at room temperature, respectively. After adding 0.8 mg of PEG-modified gold NRs to 1 ml of blood, blood absorbance at 1064 nm at different temperatures increased by an average of 24.0 times. After intravenously injecting PEG-modified gold NRs (0.87 mg/ml) into Sprague-Dawley mice, the blood absorbance at 1064 nm increased from 0.014 to 0.5. Our findings suggest that PEG-modified gold NRs injection is an efficient way to enhance light absorption by blood to Nd:YAG laser. Lasers Surg. Med. 48:790-803, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley

  7. Novel technique to treat melasma in Chinese: The combination of 2940-nm fractional Er:YAG and 1064-nm Q-switched Nd:YAG laser.

    PubMed

    Tian, Wei Cheng Brian Anthony

    2016-01-01

    Melasma is one of the most common pigmented lesions in Chinese women. Although topical therapies are the mainstay treatment, lasers are being used increasingly to treat pigmented lesions. Laser treatment of melasma is however still controversial. This is because lasers have not been able to produce complete clearance of melasma and recurrence rates are high. Laser treatments also cause complications such as hypopigmentation and post-inflammatory hyperpigmentation. In this article, we report on a novel technique using a combination of fractional 2940-nm Er:YAG and 1064-nm Q-switched Nd:YAG lasers. We achieved a rapid improvement in two cases of melasma in Chinese type III skin. The improvement was seen rapidly within a month of treatment. Follow-up at 6 months showed sustained results with no complications. This novel technique is able to safely confer excellent and sustained clearance within a short treatment time.

  8. Clinical Evaluation of Nd:YAG and 685-nm Diode Laser Therapy for Desensitization of Teeth with Gingival Recession

    PubMed Central

    Canakci, Varol; Ozdemir, Atilla; Kaya, Yavuz

    2009-01-01

    Abstract Objectives: The aim of this study was to evaluate the effectiveness of two types of lasers, the Nd:YAG laser and the 685-nm diode laser, as dentin desensitizers as well as both the immediate and late therapeutic effects on teeth with gingival recession. Materials and Methods: The study was conducted on 56 teeth in 14 patients with Miller's class 1 and 2 gingival recession with clinically elicitable dentin hypersensitivity (DH). The patients were divided into two groups: a Nd:YAG-laser-treated group and a 685-nm diode laser-treated group. DH was assessed by means of an air stimulus, and a visual analog scale (VAS) was used to measure DH. The selected teeth in the two groups received laser therapy for three sessions. Teeth subjected to Nd:YAG-laser treatment were irradiated at 1 W and 10 Hz for 60 sec at 1064 nm, and those receiving 685-nm diode laser treatment were irradiated at 25 mW and 9 Hz for 100 sec. Results: Significant reductions in DH occurred at all time points measured during the three treatment sessions in both treatment groups. Comparing the means of the responses in the three treatment sessions for the two groups revealed that the Nd:YAG laser group had a higher degree of desensitization compared to the other group (p < 0.01). The immediate and late therapeutic effects of the Nd:YAG laser were more evident than those of the 685-nm diode laser. Conclusions: Both of these lasers can be used to reduce DH without adverse effects. Desensitization of teeth with gingival recession with the Nd:YAG laser was more effective than with the diode laser. The Nd:YAG laser appears to be a promising new tool for successfully reducing DH. PMID:19281413

  9. Hyperthermia treatment of spontaneously occurring oral cavity tumors using a computer-controlled Nd:YAG laser system

    NASA Astrophysics Data System (ADS)

    Panjehpour, Masoud; Overholt, Bergein F.; Frazier, Donita L.; Klebanow, Edward R.

    1991-05-01

    Conventional hyperthermia treatment of superficial tumors in the oral cavity is difficult due to inability in accessing the lesion. A new hyperthermia technique employing near infrared Nd:YAG irradiation delivered through an optical fiber is introduced for heating oral and nasal tumors in animals. This system consisted of an Nd:YAG laser, a He-Ne laser, a computer controlled optical shutter, an interstitial thermometer, computer and a printer. The tumors were heated via surface illumination of the lesion. A thermocouple implanted in the base of the tumor provided temperature feedback for laser energy regulation. Three spontaneously occurring canine (two squamous cell carcinoma on the gum, one pigmented melanoma on the hard palate) and one feline tumor (squamous cell carcinoma on the nose) have been treated with the Nd:YAG laser-induced hyperthermia delivered following radiation therapy. The tumor temperature was maintained between 43.2-43.5 degree(s)C for one hour. Nd:YAG hyperthermia allowed efficient delivery of heat to veterinary oral and nasal lesions otherwise impossible to treat with conventional heating techniques.

  10. A randomized controlled clinical and histopathological trial comparing excisional biopsies of oral fibrous hyperplasias using CO2 and Er:YAG laser.

    PubMed

    Suter, Valerie G A; Altermatt, Hans Jörg; Bornstein, Michael M

    2017-04-01

    This study was conducted in order to compare clinical and histopathological outcomes for excisional biopsies when using pulsed CO 2 laser versus Er:YAG laser. Patients (n = 32) with a fibrous hyperplasia in the buccal mucosa were randomly allocated to the CO 2 (140 Hz, 400 μs, 33 mJ) or the Er:YAG laser (35 Hz, 297 μs, 200 mJ) group. The duration of excision, intraoperative bleeding and methods to stop the bleeding, postoperative pain (VAS; ranging 0-100), the use of analgesics, and the width of the thermal damage zone (μm) were recorded and compared between the two groups. The median duration of the intervention was 209 s, and there was no significant difference between the two methods. Intraoperative bleeding occurred in 100% of the excisions with Er:YAG and 56% with CO 2 laser (p = 0.007). The median thermal damage zone was 74.9 μm for CO 2 and 34.0 μm for Er:YAG laser (p < 0.0001). The median VAS score on the evening after surgery was 5 for the CO 2 laser and 3 for the Er:YAG group. To excise oral soft tissue lesions, CO 2 and Er:YAG lasers are both valuable tools with a short time of intervention and postoperative low pain. More bleeding occurs with the Er:YAG than CO 2 laser, but the lower thermal effect of Er:YAG laser seems advantageous for histopathological evaluation.

  11. Sub ablative Er: YAG laser irradiation on surface roughness of eroded dental enamel.

    PubMed

    Curylofo-Zotti, Fabiana Almeida; Lepri, Taísa Penazzo; Colucci, Vivian; Turssi, Cecília Pedroso; Corona, Silmara Aparecida Milori

    2015-11-01

    This study evaluated the effects of Er:YAG laser irradiation applied at varying pulse repetition rate on the surface roughness of eroded enamel. Bovine enamel slabs (n = 10) were embedded in polyester resin, ground, and polished. To erosive challenges, specimens were immersed two times per day in 20mL of concentrated orange juice (pH = 3.84) under agitation, during a two-day period. Specimens were randomly assigned to irradiation with the Er:YAG laser (focused mode, pulse energy of 60 mJ and energy density of 3.79 J/cm(2) ) operating at 1, 2, 3, or 4 Hz. The control group was left nonirradiated. Surface roughness measurements were recorded post erosion-like formation and further erosive episodes by a profilometer and observed through atomic force microscopy (AFM). Analysis of variance revealed that the control group showed the lowest surface roughness, while laser-irradiated substrates did not differ from each other following post erosion-like lesion formation. According to analysis of covariance, at further erosive episodes, the control group demonstrated lower surface roughness (P > 0.05), than any of the irradiated groups (P < 0.05). The pulse repetition rate of the Er:YAG laser did not affect roughness of dental enamel eroded. The AFM images showed that the specimens irradiated by the Er:YAG laser at 1 Hz presented a less rough surface than those irradiated at 2, 3, and 4 Hz. © 2015 Wiley Periodicals, Inc.

  12. Postoperative discomfort after Nd:YAG laser and conventional frenectomy: comparison of both genders.

    PubMed

    Akpınar, A; Toker, H; Lektemur Alpan, A; Çalışır, M

    2016-03-01

    Evidence has suggested that males and females experience and report feeling pain differently. The aim of this study was to determine the postoperative perception levels of both females and males after neodymium-doped yttrium aluminum garnet (Nd:YAG) laser frenectomy and conventional frenectomy, and to compare the perceptions between genders. Eighty-nine patients requiring frenectomy were randomly assigned to have treatment with either the conventional frenectomy or with the Nd:YAG laser. Postoperative discomfort (pain, chewing, talking) was recorded using a visual analog scale (VAS) on the operation day and postoperative days 1, 3, 7 and 10. According to the female VAS scores of the pain, chewing and speaking discomfort were statistically higher in the conventional group than those of the laser group on the operation day, and on the first and third postoperative days. Pain discomfort in males was statistically higher in the conventional group than those of the laser group on the operation day. Speaking discomfort in males was statistically higher in the conventional group than those of the laser group on the operation day and the first postoperative day. The present study indicated that Nd:YAG laser treatment used for frenectomies provides better postoperative comfort for each gender, especially in females in terms of pain, chewing and speaking than the conventional procedure up to the seventh postoperative day. According to our results, Nd:YAG laser may provide a safe, bloodless, painless surgery and an impressive alternative for frenectomy operations. © 2015 Australian Dental Association.

  13. Passive Q-switching of microchip lasers based on Ho:YAG ceramics.

    PubMed

    Lan, R; Loiko, P; Mateos, X; Wang, Y; Li, J; Pan, Y; Choi, S Y; Kim, M H; Rotermund, F; Yasukevich, A; Yumashev, K; Griebner, U; Petrov, V

    2016-06-20

    A Ho:YAG ceramic microchip laser pumped by a Tm fiber laser at 1910 nm is passively Q-switched by single- and multi-layer graphene, single-walled carbon nanotubes (SWCNTs), and Cr2+:ZnSe saturable absorbers (SAs). Employing SWCNTs, this laser generated an average power of 810 mW at 2090 nm with a slope efficiency of 68% and continuous wave to Q-switching conversion efficiency of 70%. The shortest pulse duration was 85 ns at a repetition rate of 165 kHz, and the pulse energy reached 4.9 μJ. The laser performance and pulse stability were superior compared to graphene SAs even for a different number of graphene layers (n=1 to 4). A model for the description of the Ho:YAG laser Q-switched by carbon nanostructures is presented. This modeling allowed us to estimate the saturation intensity for multi-layered graphene and SWCNT SAs to be 1.2±0.2 and 7±1  MW/cm2, respectively. When using Cr2+:ZnSe, the Ho:YAG microchip laser generated 11 ns/25 μJ pulses at a repetition rate of 14.8 kHz.

  14. Hollow fiber optics with improved durability for high-peak-power pulses of Q-switched Nd:YAG lasers.

    PubMed

    Matsuura, Yuji; Tsuchiuchi, Akio; Noguchi, Hiroshi; Miyagi, Mitsunobu

    2007-03-10

    To improve the damage threshold of hollow optical waveguides for transmitting Q-switched Nd:YAG laser pulses, we optimize the metallization processes for the inner coating of fibers. For silver-coated hollow fiber as the base, second, and third Nd:YAG lasers, drying silver films at a moderate temperature and with inert gas flow is found to be effective. By using this drying process, the resistance to high-peak-power optical pulse radiation is drastically improved for fibers fabricated with and without the sensitizing process. The maximum peak power transmitted in the fiber is greater than 20 MW. To improve the energy threshold of aluminum-coated hollow fibers for the fourth and fifth harmonics of Nd:YAG lasers, a thin silver film is added between the aluminum film and the glass substrate to increase adhesion of the aluminum coating. By using this primer layer, the power threshold improves to 3 MW for the fourth harmonics of a Q-switched Nd:YAG laser light.

  15. Synthesis, growth, structure and nonlinear optical properties of a semiorganic 2-carboxy pyridinium dihydrogen phosphate single crystal

    NASA Astrophysics Data System (ADS)

    Nagapandiselvi, P.; Baby, C.; Gopalakrishnan, R.

    2015-09-01

    A new semiorganic compound namely, 2-carboxy pyridinium dihydrogen phosphate (2CPDP) was synthesised and grown as single crystals by slow evaporation solution growth technique. Single crystal XRD showed that 2CPDP belongs to monoclinic crystal system with space group P21/n. The molecular structure was further confirmed by modern spectroscopic techniques like FT-NMR (1H, 13C &31P), FT-IR, UV-Vis-NIR and Fluorescence. The UV-Vis-NIR analysis revealed suitability of the crystal for nonlinear optical applications. The photo active nature of the material is established from fluorescence studies. TG-DSC analysis showed that 2CPDP was thermally stable up to 170 °C. The dependence of dielectric properties on frequency and temperature were also studied. Nonlinear optical absorption determined from open aperture Z-Scan analysis by employing picosecond Nd-YAG laser, revealed that 2CPDP can serve as a promising candidate for optical limiting applications.

  16. High color rendering index WLED based on YAG:Ce phosphor and CdS/ZnS core/shell quantum dots

    NASA Astrophysics Data System (ADS)

    Shen, Changyu; Li, Ke

    2009-08-01

    White LED combining of blue chip and YAG:Ce phosphor suffers from a red spectral deficiency, resulting in a relatively low value of color rendering index (CRI). In our study, for an effort to improve color rendering properties of YAG:Ce phosphor-based white LEDs, highly luminescent red-orange emitting CdS/ZnS QDs were blended with YAG:Ce phosphors. Core/shell CdS/ZnS quantum dots with the emission wavelength of 618nm, was synthesized by thermal deposition using cadmium oxide and selenium as precursors in a hot lauric acid and hexadecylamine trioctylphosphine oxide hybrid. YAG:Ce phosphor was synthesized by high-temperature solid state reaction at 900-1200°C in a slightly reducing atmosphere for 4 hours. Blends of phosphors and QDs exhibited the prominent spectral evolution with an increasing content of QDs. A hybrid white LED, which combines a blue LED with the blend of YAG phosphor and QDs with a weight ratio of 1.5:1,was demonstrated with an improved CRI value of 86.

  17. Shear test of composite bonded to dentin: Er:YAG laser versus dental handpiece preparations

    NASA Astrophysics Data System (ADS)

    Visuri, Steven R.; Gilbert, Jeremy L.; Walsh, Joseph T., Jr.; Wigdor, Harvey A.

    1995-05-01

    The erbium:YAG laser coupled with a cooling stream of water appears to be an effective means of removing dental hard tissues. However, before the procedure is deemed clinically viable, there are several important issues of safety and efficacy that need to be explored. In this study we investigated the surface that remains following laser ablation of dentin and compared the results to the use of a dental handpiece. Specifically, we studied the effect the laser radiation had on the bonding of composite to dentin. The crowns of extracted human molars were removed revealing the underlying dentin. An additional thickness of material was removed with either a dental handpiece or an Er:YAG laser by raster scanning the samples under a fixed handpiece or laser. Comparable surface roughnesses were achieved. A cylinder of composite was bonded onto the prepared surfaces following the manufacturer's directions. The dentin-composite bond was then shear stressed to failure on a universal testing apparatus and the maximum load recorded. Preliminary results indicated that laser irradiated samples had improved bond strengths. SEM photographs of the surfaces were also taken to compare the two methods of tooth preparation.

  18. VCSEL end-pumped passively Q-switched Nd:YAG laser with adjustable pulse energy.

    PubMed

    Goldberg, Lew; McIntosh, Chris; Cole, Brian

    2011-02-28

    A compact, passively Q-switched Nd:YAG laser utilizing a Cr4+:YAG saturable absorber, is end-pumped by the focused emission from an 804 nm vertical-cavity surface-emitting laser (VCSEL) array. By changing the VCSEL operating current, we demonstrated 2x adjustability in the laser output pulse energy, from 9 mJ to 18 mJ. This energy variation was attributed to changes in the angular distribution of VCSEL emission with drive current, resulting in a change in the pump intensity distribution generated by a pump-light-focusing lens.

  19. Nd:YAG-CO(2) double-pulse laser induced breakdown spectroscopy of organic films.

    PubMed

    Weidman, Matthew; Baudelet, Matthieu; Palanco, Santiago; Sigman, Michael; Dagdigian, Paul J; Richardson, Martin

    2010-01-04

    Laser-induced breakdown spectroscopy (LIBS) using double-pulse irradiation with Nd:YAG and CO(2) lasers was applied to the analysis of a polystyrene film on a silicon substrate. An enhanced emission signal, compared to single-pulse LIBS using a Nd:YAG laser, was observed from atomic carbon, as well as enhanced molecular emission from C(2) and CN. This double-pulse technique was further applied to 2,4,6-trinitrotoluene residues, and enhanced LIBS signals for both atomic carbon and molecular CN emission were observed; however, no molecular C(2) emission was detected.

  20. Mechanical properties and molecular structure analysis of subsurface dentin after Er:YAG laser irradiation.

    PubMed

    He, Zhengdi; Chen, Lingling; Hu, Xuejuan; Shimada, Yasushi; Otsuki, Masayuki; Tagami, Junji; Ruan, Shuangchen

    2017-10-01

    The purpose of this study was to evaluate the chemical and mechanical modifications in subsurface dentin layer after Er: YAG (Erbium-Yttrium Aluminium Garnet) laser irradiation, as the guidance of new dental restorative materials specific for laser irradiated dentin. Dentin disks obtained from extracted human molars were prepared and exposed to a single pulse Er:YAG laser irradiation at 80mJ/pulse. After laser irradiation the mechanical and chemical characteristics of intertubular dentin in subsurface layer were studied using nanoindentation tester and micro-Raman spectromy (μ-RS). The dentin 5-50µm depth beneath the lased surface was determined as testing area. Two-way analysis of variance (ANOVA) were used to compare the mechanical values between lased and untreated subsurface dentin (P = 0.05). A laser affected subsurface dentin layer after Er:YAG laser treatment is present. The laser irradiation is considered to decrease the mechanical properties in the superficial subsurface layer (<15µm deep). There was no significant difference in nanohardness and Young's modulus between lased subsurface dentin and untreated dentin (p > 0.05) under the depth of 15µm. However, the dentin at 5µm and 10µm depth beneath the lased surface exhibited significantly lower (~ 47.8% and ~ 33.6% respectively) hardness (p < 0.05). Er:YAG laser irradiation affected both mineral and organic components in subsurface dentin layer, a higher degree of crystallinity and reduced organic compounds occurred in the lased subsurface dentin. Under the tested laser parameters, Er:YAG laser irradiation causes lower mechanical values and reduction of organic components in subsurface dentin, which has deleterious effects on resin adhesion to this area. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.