Sample records for yard waste parameter

  1. Determination of reaction rates and activation energy in aerobic composting processes for yard waste.

    PubMed

    Uma, R N; Manjula, G; Meenambal, T

    2007-04-01

    The reaction rates and activation energy in aerobic composting processes for yard waste were determined using specifically designed reactors. Different mixture ratios were fixed before the commencement of the process. The C/N ratio was found to be optimum for a mixture ratio of 1:6 containing one part of coir pith to six parts of other waste which included yard waste, yeast sludge, poultry yard waste and decomposing culture (Pleurotosis). The path of stabilization of the wastes was continuously monitored by observing various parameters such as temperature, pH, Electrical Conductivity, C.O.D, VS at regular time intervals. Kinetic analysis was done to determine the reaction rates and activation energy for the optimum mixture ratio under forced aeration condition. The results of the analysis clearly indicated that the temperature dependence of the reaction rates followed the Arrhenius equation. The temperature coefficients were also determined. The degradation of the organic fraction of the yard waste could be predicted using first order reaction model.

  2. 40 CFR 62.15370 - What is yard waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false What is yard waste? 62.15370 Section 62.15370 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Incinerators That Burn 100 Percent Yard Waste § 62.15370 What is yard waste? Yard waste is grass, grass...

  3. 40 CFR 62.15370 - What is yard waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false What is yard waste? 62.15370 Section 62.15370 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Incinerators That Burn 100 Percent Yard Waste § 62.15370 What is yard waste? Yard waste is grass, grass...

  4. 40 CFR 60.1915 - What is yard waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false What is yard waste? 60.1915 Section 60.1915 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Incinerators That Burn 100 Percent Yard Waste § 60.1915 What is yard waste? Yard waste is grass, grass...

  5. 40 CFR 60.1915 - What is yard waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false What is yard waste? 60.1915 Section 60.1915 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Incinerators That Burn 100 Percent Yard Waste § 60.1915 What is yard waste? Yard waste is grass, grass...

  6. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  7. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  8. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  9. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  10. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  11. 40 CFR 60.1440 - What is yard waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false What is yard waste? 60.1440 Section 60.1440 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....1440 What is yard waste? Yard waste is grass, grass clippings, bushes, shrubs, and clippings from...

  12. 40 CFR 60.1440 - What is yard waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false What is yard waste? 60.1440 Section 60.1440 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED....1440 What is yard waste? Yard waste is grass, grass clippings, bushes, shrubs, and clippings from...

  13. Solid state anaerobic co-digestion of yard waste and food waste for biogas production.

    PubMed

    Brown, Dan; Li, Yebo

    2013-01-01

    Food and yard wastes are available year round at low cost and have the potential to complement each other for SS-AD. The goal of this study was to determine optimal feedstock/effluent (F/E) and food waste/yard waste mixing ratios for optimal biogas production. Co-digestion of yard and food waste was carried out at F/E ratios of 1, 2, and 3. For each F/E ratio, food waste percentages of 0%, 10%, and 20%, based on dry volatile solids, were evaluated. Results showed increased methane yields and volumetric productivities as the percentage of food waste was increased to 10% and 20% of the substrate at F/E ratios of 2 and 1, respectively. This study showed that co-digestion of food waste with yard waste at specific ratios can improve digester operating characteristics and end performance metrics over SS-AD of yard waste alone. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. 40 CFR 60.1445 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1445 Section 60.1445 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1445 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If your air curtain incinerator combusts...

  15. 40 CFR 60.1445 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1445 Section 60.1445 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1445 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If your air curtain incinerator combusts...

  16. 40 CFR 60.1925 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1925 Section 60.1925 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1925 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use...

  17. 40 CFR 60.1925 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1925 Section 60.1925 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1925 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use...

  18. 40 CFR 60.1920 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1920 Section 60.1920 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1920 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If...

  19. 40 CFR 60.1920 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1920 Section 60.1920 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1920 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If...

  20. 40 CFR 60.1445 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1445 Section 60.1445 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1445 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If your air curtain incinerator combusts...

  1. 40 CFR 60.1920 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1920 Section 60.1920 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1920 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If...

  2. 40 CFR 60.1925 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1925 Section 60.1925 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1925 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use...

  3. 40 CFR 60.1445 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1445 Section 60.1445 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1445 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If your air curtain incinerator combusts...

  4. 40 CFR 60.1445 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1445 Section 60.1445 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1445 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If your air curtain incinerator combusts...

  5. 40 CFR 60.1925 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1925 Section 60.1925 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1925 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use...

  6. 40 CFR 60.1925 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1925 Section 60.1925 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1925 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use...

  7. 40 CFR 60.1920 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1920 Section 60.1920 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1920 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If...

  8. 40 CFR 60.1920 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1920 Section 60.1920 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1920 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If...

  9. Compost: Brown gold or toxic trouble?

    USGS Publications Warehouse

    Kovacic, D.A.; Cahill, R.A.; Bicki, T.J.

    1992-01-01

    Limited data are available regarding the occurrence of potentially hazardous constituents in raw, uncomposted yard wastes, partially composted yard wastes, and finished compost (15, 16). Environmental monitoring at composting operations or facilities is lacking, and currently published research on the environmental fate of composted yard waste constituents is extremely limited. The cost of thoroughly investigating the fate of toxicants in yard waste may seem needlessly expensive, but it is much less than the cost of cleaning up contaminated sites and groundwater. Could yard waste compost sites become Superfund sites? The cost of a thorough testing program throughout the United States may be several million dollars, but that is only a fraction of the funds spent initiating and developing yard waste composting facilities, let alone the potentially much greater cost of environmental remediation. There is still time to address these problems and to develop sound state and federal guidelines for siting and operating yard waste compost facilities. The rush to implement landfill alternatives such as composting should not be the major driving force in determining legislation governing solid waste management. ?? 1991 American Chemical Society.

  10. 40 CFR 60.1440 - What is yard waste?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....1440 What is yard waste? Yard waste is grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs. They come from residential, commercial/retail, institutional, or industrial sources as...

  11. 40 CFR 60.1450 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1450 Section 60.1450 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1450 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use EPA Reference Method 9 in appendix A of...

  12. 40 CFR 60.1450 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1450 Section 60.1450 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1450 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use EPA Reference Method 9 in appendix A of...

  13. 40 CFR 60.1450 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1450 Section 60.1450 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1450 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use EPA Reference Method 9 in appendix A of...

  14. 40 CFR 60.1450 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1450 Section 60.1450 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1450 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use EPA Reference Method 9 in appendix A of...

  15. 40 CFR 60.1450 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1450 Section 60.1450 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1450 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use EPA Reference Method 9 in appendix A of...

  16. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Within...

  17. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  18. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  19. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  20. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  1. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Within...

  2. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  3. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Within...

  4. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  5. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  6. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  7. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  8. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  9. Microbiological degradation of pesticides in yard waste composting.

    PubMed

    Fogarty, A M; Tuovinen, O H

    1991-06-01

    Changes in public opinion and legislation have led to the general recognition that solid waste treatment practices must be changed. Solid-waste disposal by landfill is becoming increasingly expensive and regulated and no longer represents a long-term option in view of limited land space and environmental problems. Yard waste, a significant component of municipal solid waste, has previously not been separated from the municipal solid-waste stream. The treatment of municipal solid waste including yard waste must urgently be addressed because disposal via landfill will be prohibited by legislation. Separation of yard waste from municipal solid waste will be mandated in many localities, thus stressing the importance of scrutinizing current composting practices in treating grass clippings, leaves, and other yard residues. Yard waste poses a potential environmental health problem as a result of the widespread use of pesticides in lawn and tree care and the persistence of the residues of these chemicals in plant tissue. Yard waste containing pesticides may present a problem due to the recalcitrant and toxic nature of the pesticide molecules. Current composting processes are based on various modifications of either window systems or in-vessel systems. Both types of processes are ultimately dependent on microbial bioconversions of organic material to innocuous end products. The critical stage of the composting process is the thermophilic phase. The fate and mechanism of removal of pesticides in composting processes is largely unknown and in need of comprehensive analysis.

  10. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of this...

  11. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of this...

  12. 40 CFR 62.15380 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15380 Section 62.15380 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15380 How must I monitor opacity for air curtain incinerators that burn 100 percent yard...

  13. 40 CFR 62.15380 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15380 Section 62.15380 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15380 How must I monitor opacity for air curtain incinerators that burn 100 percent yard...

  14. 40 CFR 62.15380 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15380 Section 62.15380 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15380 How must I monitor opacity for air curtain incinerators that burn 100 percent yard...

  15. 40 CFR 62.15375 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15375 Section 62.15375 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15375 What are the emission limits for air curtain incinerators that burn 100 percent yard...

  16. 40 CFR 62.15375 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15375 Section 62.15375 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15375 What are the emission limits for air curtain incinerators that burn 100 percent yard...

  17. 40 CFR 62.15375 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15375 Section 62.15375 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15375 What are the emission limits for air curtain incinerators that burn 100 percent yard...

  18. 40 CFR 62.15380 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15380 Section 62.15380 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15380 How must I monitor opacity for air curtain incinerators that burn 100 percent yard...

  19. 40 CFR 62.15380 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15380 Section 62.15380 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15380 How must I monitor opacity for air curtain incinerators that burn 100 percent yard...

  20. 40 CFR 62.15375 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15375 Section 62.15375 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15375 What are the emission limits for air curtain incinerators that burn 100 percent yard...

  1. 40 CFR 62.15375 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15375 Section 62.15375 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15375 What are the emission limits for air curtain incinerators that burn 100 percent yard...

  2. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  3. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  4. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  5. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  6. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  7. 40 CFR 60.1930 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1930 Section 60... Incinerators That Burn 100 Percent Yard Waste § 60.1930 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  8. 40 CFR 62.15385 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 62.15385 Section 62... Incinerators That Burn 100 Percent Yard Waste § 62.15385 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  9. 40 CFR 60.1930 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1930 Section 60... Incinerators That Burn 100 Percent Yard Waste § 60.1930 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  10. 40 CFR 62.15385 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 62.15385 Section 62... Incinerators That Burn 100 Percent Yard Waste § 62.15385 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  11. 40 CFR 62.15385 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 62.15385 Section 62... Incinerators That Burn 100 Percent Yard Waste § 62.15385 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  12. 40 CFR 62.15385 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 62.15385 Section 62... Incinerators That Burn 100 Percent Yard Waste § 62.15385 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  13. 40 CFR 62.15385 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 62.15385 Section 62... Incinerators That Burn 100 Percent Yard Waste § 62.15385 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  14. 40 CFR 60.1930 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1930 Section 60... Incinerators That Burn 100 Percent Yard Waste § 60.1930 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  15. 40 CFR 60.1930 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1930 Section 60... Incinerators That Burn 100 Percent Yard Waste § 60.1930 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  16. 40 CFR 60.1930 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1930 Section 60... Incinerators That Burn 100 Percent Yard Waste § 60.1930 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  17. Effects of moisture content and initial pH in composting process on heavy metal removal characteristics of grass clipping compost used for stormwater filtration.

    PubMed

    Khan, Eakalak; Khaodhir, Sutha; Ruangrote, Darin

    2009-10-01

    Heavy metals are common contaminants in stormwater runoff. One of the devices that can be used to effectively and economically remove heavy metals from runoff is a yard waste compost stormwater filter. The primary goal of composting is to reduce waste volume rather than to produce stormwater filter media. Moisture content (MC) and initial pH, the two important parameters in composting, were studied for their effects on yard waste volume reduction and heavy metal adsorption performances of the compost. The main objective of this investigation was to examine whether the conditions that provided high yard waste volume reduction would also result in compost with good heavy metal removal performances. Manila grass was composted at different initial pHs (5-9) and MCs (30-70%) and the composts were used to adsorb cadmium, copper, lead and zinc from water. Results indicated that MC is more critical than initial pH for both volume reduction and production of compost with high metal adsorption performances. The most optimal conditions for the two attributes were not exactly the same but lower MCs of 30-40% and pH 7 or higher tended to satisfy both high volume reduction and effective metal adsorption.

  18. 40 CFR 60.1440 - What is yard waste?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Construction, renovation, and demolition wastes that are exempt from the definition of “municipal solid waste... 40 Protection of Environment 7 2012-07-01 2012-07-01 false What is yard waste? 60.1440 Section 60...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste...

  19. 40 CFR 60.1440 - What is yard waste?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Construction, renovation, and demolition wastes that are exempt from the definition of “municipal solid waste... 40 Protection of Environment 6 2011-07-01 2011-07-01 false What is yard waste? 60.1440 Section 60...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste...

  20. 40 CFR 60.1915 - What is yard waste?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... lands. Yard waste does not include two items: (a) Construction, renovation, and demolition wastes that are exempt from the definition of “municipal solid waste” in § 60.1940. (b) Clean wood that is exempt...

  1. 40 CFR 62.15370 - What is yard waste?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... lands. Yard waste does not include two items: (a) Construction, renovation, and demolition wastes that are exempt from the definition of “municipal solid waste” in § 62.15410. (b) Clean wood that is exempt...

  2. 40 CFR 60.3062 - What is an air curtain incinerator?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3062 What is... this subpart. (1) 100 percent wood waste. (2) 100 percent clean lumber. (3) 100 percent yard waste. (4...

  3. 40 CFR 60.2994 - Are air curtain incinerators regulated under this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and Compliance Times for Other Solid Waste Incineration Units That Commenced Construction On or Before... percent wood waste. (2) 100 percent clean lumber. (3) 100 percent yard waste. (4) 100 percent mixture of only wood waste, clean lumber, and/or yard waste. Model Rule—Use of Model Rule ...

  4. 40 CFR 60.2888 - Are air curtain incinerators regulated under this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Other Solid Waste Incineration Units for Which Construction is Commenced After December 9... other requirements of this subpart. (1) 100 percent wood waste. (2) 100 percent clean lumber. (3) 100 percent yard waste. (4) 100 percent mixture of only wood waste, clean lumber, and/or yard waste. ...

  5. 40 CFR 60.3062 - What is an air curtain incinerator?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3062 What is... this subpart. (1) 100 percent wood waste. (2) 100 percent clean lumber. (3) 100 percent yard waste. (4...

  6. 40 CFR 60.3062 - What is an air curtain incinerator?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3062 What is... this subpart. (1) 100 percent wood waste. (2) 100 percent clean lumber. (3) 100 percent yard waste. (4...

  7. 40 CFR 60.3062 - What is an air curtain incinerator?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3062 What is... this subpart. (1) 100 percent wood waste. (2) 100 percent clean lumber. (3) 100 percent yard waste. (4...

  8. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste...

  9. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste...

  10. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... percent wood wastes, clean lumber and/or yard waste? (a) After the date the initial test for opacity is...

  11. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... percent wood wastes, clean lumber and/or yard waste? (a) After the date the initial test for opacity is...

  12. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to...

  13. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to...

  14. MINE WASTE TECHNOLOGY PROGRAM; PHOSPHATE STABILIZATION OF HEAVY METALS CONTAMINATED MINE WASTE YARD SOILS, JOPLIN, MISSOURI NPL SITE

    EPA Science Inventory

    This document summarizes the results of Mine Waste Technology Project 22-Phosphate Stabilization of Heavy Metals-Contaminated Mine Waste Yard Soils. Mining, milling, and smelting of ores near Joplin, Missouri, have resulted in heavy metal contamination of the area. The Joplin s...

  15. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14815 What are the emission limitations for air curtain incinerators that burn 100...

  16. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... PERFORMANCE FOR NEW STATIONARY SOURCES Operator Training and Qualification Air Curtain Incinerators That Burn... incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of this...

  17. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14815 What are the emission limitations for air curtain incinerators that burn 100...

  18. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14815 What are the emission limitations for air curtain incinerators that burn 100...

  19. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  20. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  1. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  2. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2973 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  3. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  4. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  5. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2973 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  6. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2973 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  7. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14820 How must I monitor opacity for air curtain incinerators that burn 100 percent...

  8. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... and Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  9. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14820 How must I monitor opacity for air curtain incinerators that burn 100 percent...

  10. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn...

  11. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn...

  12. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14820 How must I monitor opacity for air curtain incinerators that burn 100 percent...

  13. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... and Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  14. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... and Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  15. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Modification or Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only... requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Prior to...

  16. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Modification or Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only... requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Prior to...

  17. Biochemical methane potential, biodegradability, alkali treatment and influence of chemical composition on methane yield of yard wastes.

    PubMed

    Gunaseelan, Victor Nallathambi

    2016-03-01

    In this study, the biochemical CH4 potential, rate, biodegradability, NaOH treatment and the influence of chemical composition on CH4 yield of yard wastes generated from seven trees were examined. All the plant parts were sampled for their chemical composition and subjected to the biochemical CH4 potential assay. The component parts exhibited significant variation in biochemical CH4 potential, which was reflected in their ultimate CH4 yields that ranged from 109 to 382 ml g(-1) volatile solids added and their rate constants that ranged from 0.042 to 0.173 d(-1). The biodegradability of the yard wastes ranged from 0.26 to 0.86. Variation in the biochemical CH4 potential of the yard wastes could be attributed to variation in the chemical composition of the different fractions. In the Thespesia yellow withered leaf, Tamarindus fruit pericarp and Albizia pod husk, NaOH treatment enhanced the ultimate CH4 yields by 17%, 77% and 63%, respectively, and biodegradability by 15%, 77% and 61%, respectively, compared with the untreated samples. The effectiveness of NaOH treatment varied for different yard wastes, depending on the amounts of acid detergent fibre content. Gliricidia petals, Prosopis leaf, inflorescence and immature pod, Tamarindus seeds, Albizia seeds, Cassia seeds and Delonix seeds exhibited CH4 yields higher than 300 ml g(-1) volatile solids added. Multiple linear regression models for predicting the ultimate CH4 yield and biodegradability of yard wastes were designed from the results of this work. © The Author(s) 2016.

  18. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  19. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  20. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  1. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  2. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  3. 19th century London dust-yards: a case study in closed-loop resource efficiency.

    PubMed

    Velis, Costas A; Wilson, David C; Cheeseman, Christopher R

    2009-04-01

    The material recovery methods used by dust-yards in early 19th century London, England and the conditions that led to their development, success and decline are reported. The overall system developed in response to the market value of constituents of municipal waste, and particularly the high coal ash content of household 'dust'. The emergence of lucrative markets for 'soil' and 'breeze' products encouraged dust-contractors to recover effectively 100% of the residual wastes remaining after readily saleable items and materials had been removed by the thriving informal sector. Contracting dust collection to the private sector allowed parishes to keep the streets relatively clean, without the need to develop institutional capacity, and for a period this also generated useful income. The dust-yard system is, therefore, an early example of organised, municipal-wide solid waste management, and also of public-private sector participation. The dust-yard system had been working successfully for more than 50 years before the Public Health Acts of 1848 and 1875, and was thus important in facilitating a relatively smooth transition to an institutionalised, municipally-run solid waste management system in England. The dust-yards can be seen as early precursors of modern materials recycling facilities (MRFs) and mechanical-biological treatment (MBT) plants; however, it must be emphasised that dust-yards operated without any of the environmental and occupational health considerations that are indispensable today. In addition, there are analogies between dust-yards and informal sector recycling systems currently operating in many developing countries.

  4. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  5. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  6. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  7. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  8. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  9. The feasibility of applying immature yard-waste compost to remove nitrate from agricultural drainage effluents: A preliminary assessment

    USGS Publications Warehouse

    Tsui, L.; Krapac, I.G.; Roy, W.R.

    2007-01-01

    Nitrate is a major agricultural pollutant found in drainage waters. Immature yard-waste compost was selected as a filter media to study its feasibility for removing nitrate from drainage water. Different operation parameters were tested to examine the denitrification efficiency, including the amounts of compost packed in columns, the flow rate, and the compost storage periods. The experimental results suggested that hydraulic retention time was the major factor to determine the extent of nitrate removal, although the amount of compost packed could also contribute to the nitrate removal efficiency. The effluent nitrate concentration increased as the flow rate decreased, and the compost column reduced nitrate concentrations from 20 mg/L to less than 5 mg/L within 1.5 h. The solution pH increased at the onset of experiment because of denitrification, but stabilized at a pH of about 7.8, suggesting that the compost had a buffering capacity to maintain a suitable pH for denitrification. Storing compost under air-dried conditions may diminish the extent nitrate removed initially, but the effects were not apparent after longer applications. It appeared that immature yard-waste compost may be a suitable material to remove nitrate from tile drainage water because of its relatively large organic carbon content, high microbial activity, and buffering capacity. ?? 2006 Elsevier B.V. All rights reserved.

  10. ASSESSMENT OF THE BACTERIOLOGICAL QUALITY OF COMPOST FROM A YARD WASTE PROCESSING FACILITY

    EPA Science Inventory

    Citizen concern over possible pathogenic microorganism contamination in compost and in a runoff collection pond prompted a U.S. Environmental Protection Agency (EPA) investigation. One out of eight samples collected from the distribution pile at a yard waste compost processing f...

  11. Laboratory Investigation of Rill Erosion on Compost Blankets under Concentrated Flow Conditions

    EPA Science Inventory

    A flume study was conducted using a soil, yard waste compost, and an erosion control compost to investigate the response to concentrated flow and determine if the shear stress model could be used to describe the response. Yard waste compost (YWC) and the bare Cecil soil (CS) cont...

  12. Co-composting of organic fraction of municipal solid waste mixed with different bulking waste: characterization of physicochemical parameters and microbial enzymatic dynamic.

    PubMed

    Awasthi, Mukesh Kumar; Pandey, Akhilesh Kumar; Bundela, Pushpendra Singh; Khan, Jamaluddin

    2015-04-01

    The effect of various bulking waste such as wood shaving, agricultural and yard trimming waste combined with organic fraction of municipal solid waste (OFMSW) composting was investigated through assessing their influence on microbial enzymatic activities and quality of finished compost. All three piles of OFMSW with different bulking waste were inoculated with microbial consortium. The results revealed that OFMSW combined with wood shaving and microbial consortium (Phanerochaete chrysosporium, Trichoderma viride and Pseudomonas aeruginosa) were helpful tool to facilitate the enzymatic activity and shortened composting period within 4 weeks. Maximum enzymatic activity were observed in pile 1 and 3 during the first 3 weeks, while in pile 2 relatively very low. But phosphatase activity was relatively higher in all piles until the end of the process. Maturity parameters of compost quality also favored the pile 1 as the best formulation for OFMSW composting. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. 40 CFR 60.1455 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1455 Section 60... Reconstruction is Commenced After June 6, 2001 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1455 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

  14. 40 CFR 60.1455 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1455 Section 60... Reconstruction is Commenced After June 6, 2001 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1455 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

  15. 40 CFR 60.1455 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1455 Section 60... Reconstruction is Commenced After June 6, 2001 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1455 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

  16. 40 CFR 60.1455 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1455 Section 60... Reconstruction is Commenced After June 6, 2001 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1455 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

  17. 40 CFR 60.1455 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1455 Section 60... Reconstruction is Commenced After June 6, 2001 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1455 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

  18. 7 CFR 1450.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Food waste and yard waste; and (4) Algae. Eligible material owner, for purposes of the matching payment... and trees; or (D) Algae; (ii) Waste material, including: (A) Crop residue; (B) Other vegetative waste...

  19. Urban tree and woody yard residues : another wood resource

    Treesearch

    David B. McKeever; Kenneth E. Skog

    2003-01-01

    Urban tree and woody yard residues are an important component of the municipal solid waste (MSW) stream in the United States. In 2000, approximately 14.5 million tons of urban tree and woody yard residues was generated, nearly 7% of total MSW. Some woody residues are being recovered for recycling, composting, or other uses, but a large proportion is simply discarded....

  20. Superfund Record of Decision (EPA Region 5): Allied Chemical and Ironton Coke, Ironton, OH. (Second remedial action), December 1990. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-12-28

    The 95-acre Allied Chemical and Ironton Coke site is comprised of a former coke plant and an operating tar plant in Ironton, Lawrence County, Ohio. The site is located within a coal mining region, and surrounding land use is predominantly industrial and residential. The ROD addresses contamination at all areas not previously addressed, and provides a final remedy at the site. The primary contaminants of concern affecting the soil, sediment, and ground water are VOCs including benzene; other organics including PAHs and phenols; metals including arsenic; and other inorganics including cyanide. The selected remedial action for this site includes excavatingmore » and incinerating onsite approximately 122,000 cubic yards of waste material from Lagoon 5, and 31,000 cubic yards of waste coal, followed by onsite waste fuel recovery and disposing of the residual ash offsite; in-situ bioremediation of approximately 475,000 cubic yards of waste material from Lagoons.« less

  1. Assessing Rail Yard Impact on Local Air Quality

    EPA Science Inventory

    This is a technical presentation at the Air and Waste Management Association Measurements Symposium occurring in Durham, NC in April, 2012. The presentation describes preliminary results from air pollution measurements collected surrounding a rail yard in Chicago, IL.

  2. 40 CFR 60.51 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., yard wastes, food wastes, plastics, leather, rubber, and other combustibles, and noncombustible... subpart A of this part. (a) Incinerator means any furnace used in the process of burning solid waste for the purpose of reducing the volume of the waste by removing combustible matter. (b) Solid waste means...

  3. Municipal Solid Waste Management: Recycling, Resource Recovery, and Landfills. LC Science Tracer Bullet.

    ERIC Educational Resources Information Center

    Meikle, Teresa, Comp.

    Municipal solid waste refers to waste materials generated by residential, commercial, and institutional sources, and consists predominantly of paper, glass, metals, plastics, and food and yard waste. Within the definition of the Solid Waste Disposal Act, municipal solid waste does not include sewage sludge or hazardous waste. The three main…

  4. Napropamide residues in runoff and infiltration water from pepper production.

    PubMed

    Antonious, George F; Patterson, Matthew A

    2005-01-01

    A field study was conducted on a Lowell silty loam soil of 2.7% organic matter at the Kentucky State University Research Farm, Franklin County, Kentucky. Eighteen universal soil loss equation (USLE) standard plots (22 x 3.7 m each) were established on a 10% slope. Three soil management practices were used: (i) class-A biosolids (sewage sludge), (ii) yard waste compost, each mixed with native soil at a rate of 50 ton acre(-1) on a dry-weight basis, and (iii) a no-mulch (NM) treatment (rototilled bare soil), used for comparison purposes. Devrinol 50-DF "napropamide" [N,N-diethyl-2-(1-naphthyloxy) propionamide] was applied as a preemergent herbicide, incorporated into the soil surface, and the plots were planted with 60-day-old sweet bell pepper seedlings. Napropamide residues one hour following spraying averaged 0.8, 0.4, and 0.3 microg g(-1) dry soil in sewage sludge, yard waste compost, and no-mulch treatments, respectively. Surface runoff water, runoff sediment, and napropamide residues in runoff were significantly reduced by the compost and biosolid treatments. Yard waste compost treatments increased water infiltration and napropamide residues in the vadose zone compared to sewage sludge and NM treatments. Total pepper yields from yard waste compost amended soils (9187 lbs acre(-1)) was significantly higher (P < 0.05) than yield from either the soil amended with class-A biosolids (6984 lbs acre(-1)) or the no-mulch soil (7162 lbs acre(-1)).

  5. Characterization of Products from Fast Micropyrolysis of Municipal Solid Waste Biomass

    DOE PAGES

    Klemetsrud, Bethany; Ukaew, Suchada; Thompson, Vicki S.; ...

    2016-09-05

    Biomass feedstock costs remain one of the largest impediments to biofuel production economics. Municipal solid waste (MSW) represents an attractive feedstock with year-round availability, an established collection infrastructure paid for by waste generators, low cost and the potential to be blended with higher cost feedstocks to reduce overall feedstock costs. Paper waste, yard waste and construction and demolition waste (C&D) were examined for their applicability in the pyrolysis conversion pathway. Paper waste consisted of non-recyclable paper such as mixed low grade paper, food and beverage packaging, kitchen paper wastes and coated paper; yard waste consisted of grass clippings and C&Dmore » wastes consisted of engineered wood products obtained from a construction waste landfill. We tested the waste materials for thermochemical conversion potential using a bench scale fast micro-pyrolysis process. Bio-oil yields were the highest for the C&D materials and lowest for the paper waste. The C&D wastes had the highest level of lignin derived compounds (phenolic and cyclics) while the paper waste had higher levels of carbohydrate derived compounds (aldehydes, organic acids, ketones, alcohols and sugar derived). But, the paper material had higher amounts of lignin derived compounds than expected based upon lignin content that is likely due to the presence of polyphenolic resins used in paper processing. The paper and yard wastes had significantly higher levels of ash content than the C&D wastes (14-15% versus 0.5-1.3%), which further correlated to higher levels of alkali and alkaline earth metals, which are known to reduce pyrolysis bio-oil yields. There appeared to be an inverse correlation of both calcium and potassium content with the amount of chromatographic product peaks, indicative of cracking reactions occurring during product formation. Furthermore the effect of acid washing was evaluated for grass clipping and waste paper and the bio-oil yield was increased from 58% to 73% and 67% to 73%, respectively.« less

  6. Characterization of Products from Fast Micropyrolysis of Municipal Solid Waste Biomass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klemetsrud, Bethany; Ukaew, Suchada; Thompson, Vicki S.

    Biomass feedstock costs remain one of the largest impediments to biofuel production economics. Municipal solid waste (MSW) represents an attractive feedstock with year-round availability, an established collection infrastructure paid for by waste generators, low cost and the potential to be blended with higher cost feedstocks to reduce overall feedstock costs. Paper waste, yard waste and construction and demolition waste (C&D) were examined for their applicability in the pyrolysis conversion pathway. Paper waste consisted of non-recyclable paper such as mixed low grade paper, food and beverage packaging, kitchen paper wastes and coated paper; yard waste consisted of grass clippings and C&Dmore » wastes consisted of engineered wood products obtained from a construction waste landfill. We tested the waste materials for thermochemical conversion potential using a bench scale fast micro-pyrolysis process. Bio-oil yields were the highest for the C&D materials and lowest for the paper waste. The C&D wastes had the highest level of lignin derived compounds (phenolic and cyclics) while the paper waste had higher levels of carbohydrate derived compounds (aldehydes, organic acids, ketones, alcohols and sugar derived). But, the paper material had higher amounts of lignin derived compounds than expected based upon lignin content that is likely due to the presence of polyphenolic resins used in paper processing. The paper and yard wastes had significantly higher levels of ash content than the C&D wastes (14-15% versus 0.5-1.3%), which further correlated to higher levels of alkali and alkaline earth metals, which are known to reduce pyrolysis bio-oil yields. There appeared to be an inverse correlation of both calcium and potassium content with the amount of chromatographic product peaks, indicative of cracking reactions occurring during product formation. Furthermore the effect of acid washing was evaluated for grass clipping and waste paper and the bio-oil yield was increased from 58% to 73% and 67% to 73%, respectively.« less

  7. Solid Waste Management Practices in EBRP Schools.

    ERIC Educational Resources Information Center

    Mann, Nadine L.

    1994-01-01

    A Louisiana school district has made tremendous progress toward developing and implementing an environmentally friendly solid waste management program. Packaging changes in school food service, newspaper and aluminum can recycling, and composting of leaf and yard waste have contributed to reduced waste sent to the local landfill. (MLF)

  8. 40 CFR 80.1401 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... algae species or planted trees), providing that they were intentionally applied by humans to the ground... wildfire. (6) Algae. (7) Separated yard waste or food waste, including recycled cooking and trap grease...

  9. 40 CFR 80.1401 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... algae species or planted trees), providing that they were intentionally applied by humans to the ground... wildfire. (6) Algae. (7) Separated yard waste or food waste, including recycled cooking and trap grease...

  10. Call It Trash, Garbage or Refuse: Four Case Studies Illustrate Community Waste Management Options.

    ERIC Educational Resources Information Center

    Kazzi, John W.

    1990-01-01

    Describes four successful community programs dealing with waste management issues, developed with assistance from Keep America Beautiful System: litter prevention (Beatrice, Nebraska); composting yard waste (Centralia, Illinois); recycling (Lake Jackson, Texas); and waste-to-energy incineration (Gastonia, North Carolina). Notes related education…

  11. Performance evaluation of an anaerobic/aerobic landfill-based digester using yard waste for energy and compost production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yazdani, Ramin, E-mail: ryazdani@sbcglobal.net; Civil and Environmental Engineering, University of California, One Shields Avenue, Ghausi Hall, Davis, CA 95616; Barlaz, Morton A., E-mail: barlaz@eos.ncsu.edu

    2012-05-15

    Highlights: Black-Right-Pointing-Pointer Biochemical methane potential decreased by 83% during the two-stage operation. Black-Right-Pointing-Pointer Net energy produced was 84.3 MWh or 46 kWh per million metric tons (Mg). Black-Right-Pointing-Pointer The average removal efficiency of volatile organic compounds (VOCs) was 96-99%. Black-Right-Pointing-Pointer The average removal efficiency of non-methane organic compounds (NMOCs) was 68-99%. Black-Right-Pointing-Pointer The two-stage batch digester proved to be simple to operate and cost-effective. - Abstract: The objective of this study was to evaluate a new alternative for yard waste management by constructing, operating and monitoring a landfill-based two-stage batch digester (anaerobic/aerobic) with the recovery of energy and compost. Themore » system was initially operated under anaerobic conditions for 366 days, after which the yard waste was aerated for an additional 191 days. Off gas generated from the aerobic stage was treated by biofilters. Net energy recovery was 84.3 MWh, or 46 kWh per million metric tons of wet waste (as received), and the biochemical methane potential of the treated waste decreased by 83% during the two-stage operation. The average removal efficiencies of volatile organic compounds and non-methane organic compounds in the biofilters were 96-99% and 68-99%, respectively.« less

  12. 40 CFR 60.2810 - What is an air curtain incinerator?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Commercial and Industrial Solid Waste Incineration Units that Commenced Construction On or Before November 30... “Air Curtain Incinerators” (§§ 60.2810 through 60.2870). (1) 100 percent wood waste. (2) 100 percent clean lumber. (3) 100 percent mixture of only wood waste, clean lumber, and/or yard waste. ...

  13. 40 CFR 60.2970 - What is an air curtain incinerator?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which... Wood Waste, Clean Lumber, and Yard Waste § 60.2970 What is an air curtain incinerator? (a) An air... through 60.2974 and are exempt from all other requirements of this subpart. (1) 100 percent wood waste. (2...

  14. 40 CFR 60.2970 - What is an air curtain incinerator?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which... Wood Waste, Clean Lumber, and Yard Waste § 60.2970 What is an air curtain incinerator? (a) An air... through 60.2974 and are exempt from all other requirements of this subpart. (1) 100 percent wood waste. (2...

  15. 40 CFR 60.56b - Standards for air curtain incinerators.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Municipal Waste Combustors for Which Construction is Commenced After September 20, 1994 or for Which... the capacity to combust greater than 250 tons per day of municipal solid waste and that combusts a fuel feed stream composed of 100 percent yard waste and no other municipal solid waste materials shall...

  16. Modeling the energy content of combustible ship-scrapping waste at Alang-Sosiya, India, using multiple regression analysis.

    PubMed

    Reddy, M Srinivasa; Basha, Shaik; Joshi, H V; Sravan Kumar, V G; Jha, B; Ghosh, P K

    2005-01-01

    Alang-Sosiya is the largest ship-scrapping yard in the world, established in 1982. Every year an average of 171 ships having a mean weight of 2.10 x 10(6)(+/-7.82 x 10(5)) of light dead weight tonnage (LDT) being scrapped. Apart from scrapped metals, this yard generates a massive amount of combustible solid waste in the form of waste wood, plastic, insulation material, paper, glass wool, thermocol pieces (polyurethane foam material), sponge, oiled rope, cotton waste, rubber, etc. In this study multiple regression analysis was used to develop predictive models for energy content of combustible ship-scrapping solid wastes. The scope of work comprised qualitative and quantitative estimation of solid waste samples and performing a sequential selection procedure for isolating variables. Three regression models were developed to correlate the energy content (net calorific values (LHV)) with variables derived from material composition, proximate and ultimate analyses. The performance of these models for this particular waste complies well with the equations developed by other researchers (Dulong, Steuer, Scheurer-Kestner and Bento's) for estimating energy content of municipal solid waste.

  17. 40 CFR 60.1435 - What is an air curtain incinerator?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which... Yard Waste § 60.1435 What is an air curtain incinerator? An air curtain incinerator operates by...

  18. 40 CFR 60.1435 - What is an air curtain incinerator?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which... Yard Waste § 60.1435 What is an air curtain incinerator? An air curtain incinerator operates by...

  19. 40 CFR 60.1435 - What is an air curtain incinerator?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which... Yard Waste § 60.1435 What is an air curtain incinerator? An air curtain incinerator operates by...

  20. 40 CFR 60.1435 - What is an air curtain incinerator?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which... Yard Waste § 60.1435 What is an air curtain incinerator? An air curtain incinerator operates by...

  1. 40 CFR 62.14810 - What must I do if I plan to permanently close my air curtain incinerator and not restart it?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14810 What must I do if I...

  2. 40 CFR 62.14765 - What is an air curtain incinerator?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14765 What is an air curtain incinerator? An air curtain incinerator...

  3. 40 CFR 62.14765 - What is an air curtain incinerator?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14765 What is an air curtain incinerator? An air curtain incinerator...

  4. 40 CFR 62.14810 - What must I do if I plan to permanently close my air curtain incinerator and not restart it?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14810 What must I do if I...

  5. 40 CFR 62.14770 - When must I achieve final compliance?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14770 When must I achieve final compliance? If you plan to continue...

  6. 40 CFR 62.14770 - When must I achieve final compliance?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14770 When must I achieve final compliance? If you plan to continue...

  7. 40 CFR 62.14765 - What is an air curtain incinerator?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14765 What is an air curtain incinerator? An air curtain incinerator...

  8. 40 CFR 62.14765 - What is an air curtain incinerator?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14765 What is an air curtain incinerator? An air curtain incinerator...

  9. 40 CFR 62.14810 - What must I do if I plan to permanently close my air curtain incinerator and not restart it?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14810 What must I do if I...

  10. 40 CFR 62.14770 - When must I achieve final compliance?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14770 When must I achieve final compliance? If you plan to continue...

  11. 40 CFR 62.14765 - What is an air curtain incinerator?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14765 What is an air curtain incinerator? An air curtain incinerator...

  12. 40 CFR 62.14770 - When must I achieve final compliance?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14770 When must I achieve final compliance? If you plan to continue...

  13. 40 CFR 62.14810 - What must I do if I plan to permanently close my air curtain incinerator and not restart it?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14810 What must I do if I...

  14. 40 CFR 62.14770 - When must I achieve final compliance?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14770 When must I achieve final compliance? If you plan to continue...

  15. 40 CFR 62.14810 - What must I do if I plan to permanently close my air curtain incinerator and not restart it?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14810 What must I do if I...

  16. 40 CFR 60.56b - Standards for air curtain incinerators.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... fuel feed stream composed of 100 percent yard waste and no other municipal solid waste materials shall...-minute average) is permitted during startup periods during the first 30 minutes of operation of the unit...

  17. HEAVY METAL ASPECTS OF COMPOST USE

    EPA Science Inventory

    Composts prepared from municipal solid waste, biosolids, food processing wastes, manures, yard debris, and agricultural byproducts and residues are increasingly available for agricultural use. Although many benefits are possible from use of composts, these products must be safe f...

  18. 40 CFR 60.2970 - What is an air curtain incinerator?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2970 What is an air... incinerators include both firebox and trench burner units. (b) Air curtain incinerators that burn only the...

  19. Quantification and classification of ship scraping waste at Alang-Sosiya, India.

    PubMed

    Srinivasa Reddy, M; Basha, Shaik; Sravan Kumar, V G; Joshi, H V; Ghosh, P K

    2003-12-01

    Alang-Sosiya located on the Western Coast of Gulf of Cambay, is the largest ship recycling yard in the world. Every year on average 365 ships having a mean weight (2.10x10(6)+/-7.82x10(5) LDT) are scrapped. This industry generates a huge quantity of solid waste in the form of broken wood, rubber, insulation materials, paper, metals, glass and ceramics, plastics, leather, textiles, food waste, chemicals, paints, thermocol, sponge, ash, oil mixed sponges, miscellaneous combustible and non-combustible. The quantity and composition of solid waste was collected for a period of three months and the average values are presented in this work. Sosiya had the most waste 15.63 kg/m(2) compared to Alang 10.19 kg/m(2). The combustible solid waste quantity was around 83.0% of the total solid waste available at the yard, which represents an average weight of 9.807 kg/m(2); whereas, non-combustible waste is 1.933 kg/m(2). There is not much difference between the average of total solid waste calculated from the sampling data (96.71 MT/day) and the data provided by the port authorities (96.8 MT/day).

  20. 40 CFR 62.14795 - How do I achieve final compliance?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14795 How do I achieve final compliance? For the final compliance, you must...

  1. 40 CFR 62.14795 - How do I achieve final compliance?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14795 How do I achieve final compliance? For the final compliance, you must...

  2. 40 CFR 62.14795 - How do I achieve final compliance?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14795 How do I achieve final compliance? For the final compliance, you must...

  3. 40 CFR 62.14795 - How do I achieve final compliance?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14795 How do I achieve final compliance? For the final compliance, you must...

  4. 40 CFR 62.14795 - How do I achieve final compliance?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14795 How do I achieve final compliance? For the final compliance, you must...

  5. Municipal Solid Waste Resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-06-01

    Municipal solid waste (MSW) is a source of biomass material that can be utilized for bioenergy production with minimal additional inputs. MSW resources include mixed commercial and residential garbage such as yard trimmings, paper and paperboard, plastics, rubber, leather, textiles, and food wastes. Waste resources such as landfill gas, mill residues, and waste grease are already being utilized for cost-effective renewable energy generation. MSW for bioenergy also represents an opportunity to divert greater volumes of residential and commercial waste from landfills.

  6. Waste-to-Energy Laboratory. Grades 8-12.

    ERIC Educational Resources Information Center

    HAZWRAP, The Hazardous Waste Remedial Actions Program.

    This brochure contains an activity for grades 8-12 students that focuses on the reuse of waste as an energy source by burning and converting it into energy. For this experiment students construct a calorimeter from simple recyclable material. The calorimeter is used to measure the amount of energy stored in paper and yard waste that could be used…

  7. 77 FR 43002 - Hazardous Waste Management System: Identification and Listing of Hazardous Waste Amendment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-23

    ... Subjects in 40 CFR Part 261 Environmental protection, Hazardous waste, Recycling, and Reporting and... a maximum annual rate of 200 cubic yards per year must be disposed in a lined Subtitle D landfill... forth in paragraph 1, Phillips 66 can dispose of the processed sludge in a lined Subtitle D landfill...

  8. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  9. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  10. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  11. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  12. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  13. Life cycle assessment of biochar systems: estimating the energetic, economic, and climate change potential.

    PubMed

    Roberts, Kelli G; Gloy, Brent A; Joseph, Stephen; Scott, Norman R; Lehmann, Johannes

    2010-01-15

    Biomass pyrolysis with biochar returned to soil is a possible strategy for climate change mitigation and reducing fossil fuel consumption. Pyrolysis with biochar applied to soils results in four coproducts: long-term carbon (C) sequestration from stable C in the biochar, renewable energy generation, biochar as a soil amendment, and biomass waste management. Life cycle assessment was used to estimate the energy and climate change impacts and the economics of biochar systems. The feedstocks analyzed represent agricultural residues (corn stover), yard waste, and switchgrass energy crops. The net energy of the system is greatest with switchgrass (4899 MJ t(-1) dry feedstock). The net greenhouse gas (GHG) emissions for both stover and yard waste are negative, at -864 and -885 kg CO(2) equivalent (CO(2)e) emissions reductions per tonne dry feedstock, respectively. Of these total reductions, 62-66% are realized from C sequestration in the biochar. The switchgrass biochar-pyrolysis system can be a net GHG emitter (+36 kg CO(2)e t(-1) dry feedstock), depending on the accounting method for indirect land-use change impacts. The economic viability of the pyrolysis-biochar system is largely dependent on the costs of feedstock production, pyrolysis, and the value of C offsets. Biomass sources that have a need for waste management such as yard waste have the highest potential for economic profitability (+$69 t(-1) dry feedstock when CO(2)e emission reductions are valued at $80 t(-1) CO(2)e). The transportation distance for feedstock creates a significant hurdle to the economic profitability of biochar-pyrolysis systems. Biochar may at present only deliver climate change mitigation benefits and be financially viable as a distributed system using waste biomass.

  14. 40 CFR 60.3078 - What definitions must I know?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shavings. Wood waste does not include: (1) Grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs from residential, commercial/retail, institutional, or industrial sources as part of..., flake board, and oriented strand board). Yard waste means grass, grass clippings, bushes, shrubs, and...

  15. 40 CFR 60.2977 - What definitions must I know?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shavings. Wood waste does not include: (1) Grass, grass clippings, bushes, shrubs, and clippings from bushes and shrubs from residential, commercial/retail, institutional, or industrial sources as part of..., flake board, and oriented strand board). Yard waste means grass, grass clippings, bushes, shrubs, and...

  16. Comparison of solid-state to liquid anaerobic digestion of lignocellulosic feedstocks for biogas production.

    PubMed

    Brown, Dan; Shi, Jian; Li, Yebo

    2012-11-01

    Lignocellulosic biomass feedstocks (switchgrass, corn stover, wheat straw, yard waste, leaves, waste paper, maple, and pine) were evaluated for methane production under liquid anaerobic digestion (L-AD) and solid-state anaerobic digestion (SS-AD). No significant difference in methane yield between L-AD and SS-AD, except for waste paper and pine, were found. However, the volumetric productivity was 2- to 7-fold greater in the SS-AD system compared with the L-AD system, except for paper. Methane yields from corn stover, wheat straw, and switchgrass were 2-5 times higher than those from yard waste, maple, and pine biomass. Waste paper had a methane yield of only 15 L/kg VS caused by souring during SS-AD due to organic overloading. Pine also had very low biogas yield of 17 L/kg VS, indicating the need for pretreatment prior to SS-AD. The findings of this study can guide future studies to improve the efficiency and stability of SS-AD of lignocellulosic biomass. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2974 Am I required to apply for and obtain a title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber...

  18. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2974 Am I required to apply for and obtain a title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber...

  19. The Three Rs: Reduce, Reuse, Recycle.

    ERIC Educational Resources Information Center

    Science Activities, 1991

    1991-01-01

    A student hand-out for a recycling unit defines the terms reduce, recycle, and reuse as they relate to solid waste management. Presents the characteristics of recyclable items such as yard wastes, metals, glass, and paper. Lists organizations through which more information about recycling can be obtained. (MCO)

  20. Innovative Soft-Sided Waste Packaging System Implementation at a Small Department of Energy Environmental Restoration/Waste Management (ER/WM) Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolf, J.

    2002-02-28

    Weiss Associates (WA) performs a broad range of environmental restoration/waste management (ER/WM) activities for the U.S. Department of Energy (DOE) at the former Laboratory for Energy-Related Health Research (LEHR), University of California, Davis (UC Davis). Over the last three years, the LEHR ER/WM program transitioned from a baseline packaging system of steel, 2.7 cubic meter (3.5-cubic yard) B-25 boxes to a 7.0 cubic meter (9.1-cubic yard) soft-sided container (Lift Liner) system. The transition increased efficiencies in processing, packaging, and storage, and when combined with decreased procurement costs, achieved a $402,000 cost savings (Table I). Additional disposal costs between $128,600 andmore » $182,600 were avoided by minimizing void space. Future cost savings by the end of fiscal year 2003 are projected between $250,640 and $1,003,360.« less

  1. 40 CFR 62.14805 - What must I do if I close my air curtain incinerator and then restart it?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... DESIGNATED FACILITIES AND POLLUTANTS Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14805 What must I do if I close my...

  2. 40 CFR 62.14805 - What must I do if I close my air curtain incinerator and then restart it?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... DESIGNATED FACILITIES AND POLLUTANTS Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14805 What must I do if I close my...

  3. 40 CFR 62.14805 - What must I do if I close my air curtain incinerator and then restart it?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... DESIGNATED FACILITIES AND POLLUTANTS Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14805 What must I do if I close my...

  4. 40 CFR 62.14805 - What must I do if I close my air curtain incinerator and then restart it?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... DESIGNATED FACILITIES AND POLLUTANTS Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14805 What must I do if I close my...

  5. 40 CFR 62.14805 - What must I do if I close my air curtain incinerator and then restart it?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14805 What must I do if I close my...

  6. The seasonal evolution of fruit, vegetable and yard wastes by mono, co and tri-digestion at Hyderabad, Sindh Pakistan.

    PubMed

    Korai, Muhammad Safar; Mahar, Rasool Bux; Uqaili, Muhammad Aslam

    2018-01-01

    The contribution of biowastes in municipal solid waste (MSW) is increasing day by day and being dumped in open atmosphere along with other wastes in every city of Pakistan. This study was formulated to evaluate the feasibility of biowastes such as fruit, vegetable and yard wastes of different seasons individual and mixing at different ratios to optimize methane production at Hyderabad Sindh, Pakistan. Batch digestion of selected samples was conducted for 40 days under mesophilic condition. Methane yield of individual fruit, vegetable and yard wastes (FrVYW) of summer and winter season was obtained in the range of 0.36-0.40 L/g VS and 0.39-0.44 L/g VS added respectively. The results of co-digestion of FrVYW of summer and winter season were observed in the range of 0.42-0.45 L/g VS added and 0.46 to 0.54 L/g VS added respectively. The results of tri-digestion of FrVYW of summer and winter season were achieved in the range of 0.46-0.53 L/g VS added and 0.56-0.62 L/g VS added respectively. Findings of study showed that methane production potential of tri-digestions were highest than all of others and that of co-digestion were higher than mono-digestion of FrVYW. Overall results of study concluded that tri-digestion of FrVYW at the equal blending ratio reported highest methane potential. Therefore, the study recommended that tri-digestion of FrVYW at equal mixing ratio is an optimal ratio for anaerobic digestion process to yield maximum methane production from FrVYW. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Solid-state anaerobic co-digestion of spent mushroom substrate with yard trimmings and wheat straw for biogas production.

    PubMed

    Lin, Yunqin; Ge, Xumeng; Li, Yebo

    2014-10-01

    Spent mushroom substrate (SMS) is a biomass waste generated from mushroom production. About 5 kg of SMS is generated for every kg of mushroom produced. In this study, solid state anaerobic digestion (SS-AD) of SMS, wheat straw, yard trimmings, and their mixtures was investigated at different feedstock to effluent ratios. SMS was found to be highly degradable, which resulted in inhibition of SS-AD due to volatile fatty acid (VFA) accumulation and a decrease in pH. This issue was addressed by co-digestion of SMS with either yard trimmings or wheat straw. SS-AD of SMS/yard trimmings achieved a cumulative methane yield of 194 L/kg VS, which was 16 and 2 times higher than that from SMS and yard trimmings, respectively. SS-AD of SMS/wheat straw obtained a cumulative methane yield of 269 L/kg VS, which was 23 times as high as that from SMS and comparable to that from wheat straw. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Anaerobic digestion of organic waste in Japan: the first demonstration plant at Kyoto City.

    PubMed

    Komatsu, T; Kimura, T; Kuriyama, Y; Isshiki, Y; Kawano, T; Hirao, T; Masuda, M; Yokoyama, K; Matsumoto, T; Takeda, M

    2002-01-01

    Recycling of Municipal Solid Waste is vigorously promoted in Japan and the necessity of energy recovery from organic waste is increasing. An anaerobic digestion demonstration plant for organic waste in Kyoto City, Japan has been operated for about two years. Three kinds of wastes (garbage and leftovers from hotels, yard waste and used paper) mixed at various ratios are used. The plant has maintained stable operations with each mixture, generating biogas by the decomposition of VS at the rate of about 820 m3N/ton-VS.

  9. Effect of Crotalaria juncea Amendment on Squash Infected with Meloidogyne incognita.

    PubMed

    Wang, K-H; McSorley, R; Gallaher, R N

    2004-09-01

    Two greenhouse experiments were conducted to examine the effect of Crotalaria juncea amendment on Meloidogyne incognita population levels and growth of yellow squash (Cucurbita pepo). In the first experiment, four soils with a long history of receiving yard waste compost (YWC+), no-yard-waste compost (YWC-), conventional tillage, or no-tillage treatments were used; in the second experiment, only one recently cultivated soil was used. Half of the amount of each soil received air-dried residues of C. juncea as amendment before planting squash, whereas the other half did not. Crotalaria juncea amendment increased squash shoot and root weights in all soils tested, except in YWC+ soil where the organic matter content was high without the amendment. The amendment suppressed the numbers of M. incognita if the inoculum level was low, and when the soil contained relatively abundant nematode-antagonistic fungi. Microwaved soil resulted in greater numbers of M. incognita and free-living nematodes than frozen or untreated soil, indicating nematode-antagonistic microorganisms played a role in nematode suppression. The effects of C. juncea amendment on nutrient cycling were complex. Amendment with C. juncea increased the abundance of free-living nematodes and Harposporium anguillulae, a fungus antagonistic to them in the second experiment but not in the first experiment. Soil histories, especially long-term yard waste compost treatments that increased soil organic matter, can affect the performance of C. juncea amendment.

  10. Effect of compost age and composition on the atrazine removal from solution.

    PubMed

    Tsui, Lo; Roy, William R

    2007-01-02

    Compost samples from two composting facilities, the Urbana (Illinois) Landscape Recycling Center (ULRC) and Illinois State University (ISU), were selected to examine the effect of compost age on atrazine removal from solution. The ULRC samples were made from yard waste without an additional nitrogen source. The ISU samples were made from yard waste or sawdust with the addition of manure. The 6-month-old ULRC compost had the greater capacity to remove atrazine from solution, which we attributed to its greater organic carbon content. The addition of nitrate into ULRC compost could influence the extent of atrazine removal, but did not have a significant impact on atrazine removal when applied to ISU compost, probably because manure was added to the yard waste to produce the compost. For both ULRC and ISU samples, the presence of sodium azide inhibited atrazine removal, suggesting that microbial activity contributed to the atrazine removal. Metabolic analysis demonstrated that hydroxyatrazine was the major identified metabolite that accumulated in solution before significant ring mineralization could occur. When compared with the ISU compost, the ULRC compost sample had a greater capacity to remove atrazine from solution during the 120 days of study because of the larger humic acid content. The experimental results suggested that less-mature compost may be better suited for environmental applications such as removing atrazine from tile-drainage waters.

  11. Effect of compost age and composition on the atrazine removal from solution

    USGS Publications Warehouse

    Tsui, L.; Roy, W.R.

    2007-01-01

    Compost samples from two composting facilities, the Urbana (Illinois) Landscape Recycling Center (ULRC) and Illinois State University (ISU), were selected to examine the effect of compost age on atrazine removal from solution. The ULRC samples were made from yard waste without an additional nitrogen source. The ISU samples were made from yard waste or sawdust with the addition of manure. The 6-month-old ULRC compost had the greater capacity to remove atrazine from solution, which we attributed to its greater organic carbon content. The addition of nitrate into ULRC compost could influence the extent of atrazine removal, but did not have a significant impact on atrazine removal when applied to ISU compost, probably because manure was added to the yard waste to produce the compost. For both ULRC and ISU samples, the presence of sodium azide inhibited atrazine removal, suggesting that microbial activity contributed to the atrazine removal. Metabolic analysis demonstrated that hydroxyatrazine was the major identified metabolite that accumulated in solution before significant ring mineralization could occur. When compared with the ISU compost, the ULRC compost sample had a greater capacity to remove atrazine from solution during the 120 days of study because of the larger humic acid content. The experimental results suggested that less-mature compost may be better suited for environmental applications such as removing atrazine from tile-drainage waters. ?? 2006 Elsevier B.V. All rights reserved.

  12. Effect of Crotalaria juncea Amendment on Squash Infected with Meloidogyne incognita

    PubMed Central

    Wang, K.-H.; McSorley, R.; Gallaher, R. N.

    2004-01-01

    Two greenhouse experiments were conducted to examine the effect of Crotalaria juncea amendment on Meloidogyne incognita population levels and growth of yellow squash (Cucurbita pepo). In the first experiment, four soils with a long history of receiving yard waste compost (YWC+), no-yard-waste compost (YWC-), conventional tillage, or no-tillage treatments were used; in the second experiment, only one recently cultivated soil was used. Half of the amount of each soil received air-dried residues of C. juncea as amendment before planting squash, whereas the other half did not. Crotalaria juncea amendment increased squash shoot and root weights in all soils tested, except in YWC+ soil where the organic matter content was high without the amendment. The amendment suppressed the numbers of M. incognita if the inoculum level was low, and when the soil contained relatively abundant nematode-antagonistic fungi. Microwaved soil resulted in greater numbers of M. incognita and free-living nematodes than frozen or untreated soil, indicating nematode-antagonistic microorganisms played a role in nematode suppression. The effects of C. juncea amendment on nutrient cycling were complex. Amendment with C. juncea increased the abundance of free-living nematodes and Harposporium anguillulae, a fungus antagonistic to them in the second experiment but not in the first experiment. Soil histories, especially long-term yard waste compost treatments that increased soil organic matter, can affect the performance of C. juncea amendment. PMID:19262819

  13. 40 CFR 60.2970 - What is an air curtain incinerator?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What is an air curtain incinerator? 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2970 What is an air curtain incinerator? (a) An air curtain incinerator operates by forcefully projecting a curtain of air...

  14. Assessing the impacts of changes in treatment technology on energy and greenhouse gas balances for organic waste and wastewater treatment using historical data.

    PubMed

    Poulsen, Tjalfe G; Hansen, Jens Aage

    2009-11-01

    Historical data on organic waste and wastewater treatment during the period of 1970-2020 were used to assess the impact of treatment on energy and greenhouse gas (GHG) balances. The assessment included the waste fractions: Sewage sludge, food waste, yard waste and other organic waste (paper, plastic, etc.). Data were collected from Aalborg, a municipality located in Northern Denmark. During the period from 1970-2005, Aalborg Municipality has changed its waste treatment strategy from landfilling of all wastes toward composting of yard waste and incineration with combined heat and power production from the remaining organic municipal waste. Wastewater treatment has changed from direct discharge of untreated wastewater to full organic matter and nutrient (N, P) removal combined with anaerobic digestion of the sludge for biogas production with power and heat generation. These changes in treatment technology have resulted in the waste and wastewater treatment systems in Aalborg progressing from being net consumers of energy and net emitters of GHG, to becoming net producers of energy and net savers of GHG emissions (due to substitution of fossil fuels elsewhere). If it is assumed that the organic waste quantity and composition is the same in 1970 and 2005, the technology change over this time period has resulted in a progression from a net annual GHG emission of 200 kg CO( 2)-eq. capita(-1) in 1970 to a net saving of 170 kg CO(2)-eq. capita(-1) in 2005 for management of urban organic wastes.

  15. Revisiting the elemental composition and the calorific value of the organic fraction of municipal solid wastes.

    PubMed

    Komilis, Dimitrios; Evangelou, Alexandros; Giannakis, Georgios; Lymperis, Constantinos

    2012-03-01

    In this work, the elemental content (C, N, H, S, O), the organic matter content and the calorific value of various organic components that are commonly found in the municipal solid waste stream were measured. The objective of this work was to develop an empirical equation to describe the calorific value of the organic fraction of municipal solid waste as a function of its elemental composition. The MSW components were grouped into paper wastes, food wastes, yard wastes and plastics. Sample sizes ranged from 0.2 to 0.5 kg. In addition to the above individual components, commingled municipal solid wastes were sampled from a bio-drying facility located in Crete (sample sizes ranged from 8 to 15 kg) and were analyzed for the same parameters. Based on the results of this work, an improved empirical model was developed that revealed that carbon, hydrogen and oxygen were the only statistically significant predictors of calorific value. Total organic carbon was statistically similar to total carbon for most materials in this work. The carbon to organic matter ratio of 26 municipal solid waste substrates and of 18 organic composts varied from 0.40 to 0.99. An approximate chemical empirical formula calculated for the organic fraction of commingled municipal solid wastes was C(32)NH(55)O(16). Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Solid waste and pancreatic cancer: an ecologic study in Florida, USA.

    PubMed

    Schwartz, G G; Skinner, H G; Duncan, R

    1998-10-01

    Other than cigarette smoking, modifiable risk factors for pancreatic cancer have not been consistently identified. This study explored the ecologic relationship between pancreatic cancer incidence and measures of cigarette smoking, income, and solid waste collection for Florida's 67 counties. We used Florida's population-based cancer registry to compare county-specific incidence rates of pancreatic cancer among Whites to median household income, the per county prevalence of cigarette smoking, and to measures of per capita municipal solid waste collected. County-specific incidence rates for pancreatic cancer ranged from 0 to 8.1 per 100,000 per year and were significantly correlated with income (r = 0.35), cigarette smoking (r = 0.39), and solid waste (r = 0.47). The correlation between pancreatic cancer and solid waste was largely attributable to one sub-component of solid waste, yard trash (grass clippings, and tree and shrub trimmings) (r = 0.42). Using a stepwise regression procedure, only cigarette smoking and yard trash remained significant in the model. These data suggest that some factor associated with grass and tree trimmings, e.g. insecticides and herbicides, may increase the risk for pancreatic cancer. This hypothesis is consistent with several reports of pancreatic cancer and insecticide exposure in individuals and may suggest new avenues for research in pancreatic cancer.

  17. An easy-to-use tool for the evaluation of leachate production at landfill sites.

    PubMed

    Grugnaletti, Matteo; Pantini, Sara; Verginelli, Iason; Lombardi, Francesco

    2016-09-01

    A simulation program for the evaluation of leachate generation at landfill sites is herein presented. The developed tool is based on a water balance model that accounts for all the key processes influencing leachate generation through analytical and empirical equations. After a short description of the tool, different simulations on four Italian landfill sites are shown. The obtained results revealed that when literature values were assumed for the unknown input parameters, the model provided a rough estimation of the leachate production measured in the field. In this case, indeed, the deviations between observed and predicted data appeared, in some cases, significant. Conversely, by performing a preliminary calibration for some of the unknown input parameters (e.g. initial moisture content of wastes, compression index), in nearly all cases the model performances significantly improved. These results although showed the potential capability of a water balance model to estimate the leachate production at landfill sites also highlighted the intrinsic limitation of a deterministic approach to accurately forecast the leachate production over time. Indeed, parameters such as the initial water content of incoming waste and the compression index, that have a great influence on the leachate production, may exhibit temporal variation due to seasonal changing of weather conditions (e.g. rainfall, air humidity) as well as to seasonal variability in the amount and type of specific waste fractions produced (e.g. yard waste, food, plastics) that make their prediction quite complicated. In this sense, we believe that a tool such as the one proposed in this work that requires a limited number of unknown parameters, can be easier handled to quantify the uncertainties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. 40 CFR 60.3062 - What is an air curtain incinerator?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain of air across an open, integrated combustion chamber (fire box) or open pit or trench (trench... 40 Protection of Environment 6 2011-07-01 2011-07-01 false What is an air curtain incinerator? 60... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3062 What is...

  19. Prototyping the Use of Dispersion Models to Predict Ground Concentrations During Burning of Deployed Military Waste

    DTIC Science & Technology

    2012-03-22

    Fabric 3.85% Polypropylene (PP) (Class 5 plastics, soda cups, yogurt boxes, syrup bottles, prescription bottles) 1.32% Yard waste 5.67% PVC (Class 3...plastics, milk jugs) 1.23% Cardboard 31.33% Polypropylene (PP) (Class 5 plastics, soda cups, yogurt boxes, syrup bottles, prescription bottles) 0.62

  20. The potential of biogas production from municipal solid waste in a tropical climate.

    PubMed

    Getahun, Tadesse; Gebrehiwot, Mulat; Ambelu, Argaw; Van Gerven, Tom; Van der Bruggen, Bart

    2014-07-01

    The objective of this study was to estimate the potential of organic municipal solid waste generated in an urban setting in a tropical climate to produce biogas. Five different categories of wastes were considered: fruit waste, food waste, yard waste, paper waste, and mixed waste. These fractions were assessed for their efficiency for biogas production in a laboratory-scale batch digester for a total period of 8 weeks at a temperature of 15-30 °C. During this period, fruit waste, food waste, yard waste, paper waste, and mixed waste were observed to produce 0.15, 0.17, 0.10, 0.08, and 0.15 m(3) of biogas per kilogram of volatile solids, respectively. The biogas produced and caloric value of each feedstock was in the range of 1.25 × 10(-3) m(3) (17 kWh)/cap/day (paper waste) to 15 × 10(-3) m(3) (170 kWh)/cap/day (mixed waste). Paper waste produced the least (<1×10(-3)(<17.8 kWh)/cap/day), and mixed waste produced the highest methane yield (10 × 10(-3) m(3) (178 kWh)/cap/day). Thus, mixed waste was found to be more efficient than other feedstocks for biogas and methane production; this was mainly related to the better C/N ratio in mixed waste. Taking the total waste production in Jimma into account, the total mixed organic solid waste could produce 865 × 10(3) m(3) (5.4 m(3)/capita) of biogas or 537 × 10(3) m(3) (3.4 m(3)/capita) of methane per year. The total caloric value of methane production potential from mixed organic municipal solid waste was many times higher than the total energy requirement of the area.

  1. Impacts of soil conditioners and water table management on phosphorus loss in tile drainage from a clay loam soil.

    PubMed

    Zhang, T Q; Tan, C S; Zheng, Z M; Welacky, T W; Reynolds, W D

    2015-03-01

    Adoption of waste-derived soil conditioners and refined water management can improve soil physical quality and crop productivity of fine-textured soils. However, the impacts of these practices on water quality must be assessed to ensure environmental sustainability. We conducted a study to determine phosphorus (P) loss in tile drainage as affected by two types of soil conditioners (yard waste compost and swine manure compost) and water table management (free drainage and controlled drainage with subirrigation) in a clay loam soil under corn-soybean rotation in a 4-yr period from 1999 to 2003. Tile drainage flows were monitored and sampled on a year-round continuous basis using on-site auto-sampling systems. Water samples were analyzed for dissolved reactive P (DRP), particulate P (PP), and total P (TP). Substantially greater concentrations and losses of DRP, PP, and TP occurred with swine manure compost than with control and yard waste compost regardless of water table management. Compared with free drainage, controlled drainage with subirrigation was an effective way to reduce annual and cumulative losses of DRP, PP, and TP in tile drainage through reductions in flow volume and P concentration with control and yard waste compost but not with swine manure compost. Both DRP and TP concentrations in tile drainage were well above the water quality guideline for P, affirming that subsurface loss of P from fine-textured soils can be one critical source for freshwater eutrophication. Swine manure compost applied as a soil conditioner must be optimized by taking water quality impacts into consideration. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  2. Energy content of municipal solid waste bales.

    PubMed

    Ozbay, Ismail; Durmusoglu, Ertan

    2013-07-01

    Baling technology is a preferred method for temporary storage of municipal solid waste (MSW) prior to final disposal. If incineration is intended for final disposal of the bales, the energy content of the baled MSW gains importance. In this study, nine cylindrical bales containing a mix of different waste materials were constructed and several parameters, including total carbon (TC), total organic carbon (TOC), total Kjeldahl nitrogen, moisture content, loss on ignition, gross calorific value and net calorific value (NCV) were determined before the baling and at the end of 10 months of storage. In addition, the relationships between the waste materials and the energy contents of the bales were investigated by the bivariate correlation analyses. At the end, linear regression models were developed in order to forecast the decrease of energy content during storage. While the NCVs of the waste materials before the baling ranged between 6.2 and 23.7 MJ kg(-1) dry basis, they ranged from 1.0 to 16.4 MJ kg(-1) dry basis at the end of the storage period. Moreover, food wastes exhibited the highest negative correlation with NCVs, whereas plastics have significant positive correlation with both NCVs and TCs. Similarly, TOCs and carbon/nitrogen ratios decreased with the increase in food amounts inside the bales. In addition, textile, wood and yard wastes increase the energy content of the bales slightly over the storage period.

  3. 40 CFR 60.1940 - What definitions must I know?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... plastics or rubber recycling unit as specified under Applicability of State Plans (§ 60.1555(h) and (i...) of the combustion unit. Yard waste means grass, grass clippings, bushes, shrubs, and clippings from...

  4. 40 CFR 60.1940 - What definitions must I know?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... plastics or rubber recycling unit as specified under Applicability of State Plans (§ 60.1555(h) and (i...) of the combustion unit. Yard waste means grass, grass clippings, bushes, shrubs, and clippings from...

  5. Agents Contribute to Statewide Program Designs in Yardwaste Management.

    ERIC Educational Resources Information Center

    May, James H.; And Others

    1994-01-01

    A survey of 125 Virginia extension agents received 90 responses demonstrating their knowledge of yard waste management and composting. Results were used to develop public education programs and pilot projects about composting. (SK)

  6. Surface debris inventory at White Wing Scrap Yard, Oak Ridge Reservation, Oak Ridge, Tennessee. Environmental Restoration Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez, R.E.; Tiner, P.F.; Williams, J.K.

    1992-08-01

    An inventory of surface debris in designated grid blocks at the White Wing Scrap Yard [Waste Area Grouping 11 (WAG 11)] was conducted intermittently from February through June 1992 by members of the Measurement Applications and Development Group, Health and Safety Research Division, Oak Ridge National Laboratory (ORNL) at the request of ORNL Environmental Restoration (ER) Program personnel. The objectives of this project are outlined in the following four phases: (1) estimate the amount (volume) and type (e.g., glass, metal and plastics) of surface waste material in 30 designated grid blocks (100- by 100-ft grids); (2) conduct limited air samplingmore » for organic chemical pollutants at selected locations (e.g., near drums, in holes, or other potentially contaminated areas); (3) conduct a walkover gamma radiation scan extending outward (approximately 50 ft) beyond the proposed location of the WAG 11 perimeter fence; and (4) recommend one grid block as a waste staging area. This recommendation is based on location and accessibility for debris staging/transport activities and on low levels of gamma radiation in the grid block.« less

  7. Surface debris inventory at White Wing Scrap Yard, Oak Ridge Reservation, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez, R.E.; Tiner, P.F.; Williams, J.K.

    1992-08-01

    An inventory of surface debris in designated grid blocks at the White Wing Scrap Yard [Waste Area Grouping 11 (WAG 11)] was conducted intermittently from February through June 1992 by members of the Measurement Applications and Development Group, Health and Safety Research Division, Oak Ridge National Laboratory (ORNL) at the request of ORNL Environmental Restoration (ER) Program personnel. The objectives of this project are outlined in the following four phases: (1) estimate the amount (volume) and type (e.g., glass, metal and plastics) of surface waste material in 30 designated grid blocks (100- by 100-ft grids); (2) conduct limited air samplingmore » for organic chemical pollutants at selected locations (e.g., near drums, in holes, or other potentially contaminated areas); (3) conduct a walkover gamma radiation scan extending outward (approximately 50 ft) beyond the proposed location of the WAG 11 perimeter fence; and (4) recommend one grid block as a waste staging area. This recommendation is based on location and accessibility for debris staging/transport activities and on low levels of gamma radiation in the grid block.« less

  8. 40 CFR 62.15410 - What definitions must I know?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pyrolysis or combustion units located at a plastics or rubber recycling unit as specified under § 62.15020(h... furnace (for example, radiant heat transfer section) of the combustion unit. Yard waste means grass, grass...

  9. 40 CFR 62.15410 - What definitions must I know?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pyrolysis or combustion units located at a plastics or rubber recycling unit as specified under § 62.15020(h... furnace (for example, radiant heat transfer section) of the combustion unit. Yard waste means grass, grass...

  10. Evaluation of composting as a strategy for managing organic wastes from a municipal market in Nicaragua.

    PubMed

    Aulinas Masó, Montserrat; Bonmatí Blasi, August

    2008-07-01

    A pilot-scale study was undertaken to evaluate alternatives to the solid waste management of a Central American municipal market located in Estelí, Nicaragua. The municipal solid waste from the local market is the second largest contributor to the municipal solid waste (MSW) stream. Waste from the market without any previous sorting or treatment is open dumped. The options evaluated in this study were windrow composting, windrow composting with yard waste, bokashi and vermicompost. Significant differences between the properties of composts produced were found; however, all of them reduce the initial waste volume and are potential useful agronomic products for a survival agrarian milieu.

  11. Immobilisation of Cu, Pb and Zn in Scrap Metal Yard Soil Using Selected Waste Materials.

    PubMed

    Kamari, A; Putra, W P; Yusoff, S N M; Ishak, C F; Hashim, N; Mohamed, A; Isa, I M; Bakar, S A

    2015-12-01

    Immobilisation of heavy metals in a 30-year old active scrap metal yard soil using three waste materials, namely coconut tree sawdust (CTS), sugarcane bagasse (SB) and eggshell (ES) was investigated. The contaminated soil was amended with amendments at application rates of 0 %, 1 % and 3 % (w/w). The effects of amendments on metal accumulation in water spinach (Ipomoea aquatica) and soil metal bioavailability were studied in a pot experiment. All amendments increased biomass yield and reduced metal accumulation in the plant shoots. The bioconcentration factor and translocation factor values of the metals were in the order of Zn > Cu > Pb. The addition of ES, an alternative source of calcium carbonate (CaCO3), has significantly increased soil pH and resulted in marked reduction in soil metal bioavailability. Therefore, CTS, SB and ES are promising low-cost immobilising agents to restore metal contaminated land.

  12. Converting lignocellulosic solid waste into ethanol for the State of Washington: an investigation of treatment technologies and environmental impacts.

    PubMed

    Schmitt, Elliott; Bura, Renata; Gustafson, Rick; Cooper, Joyce; Vajzovic, Azra

    2012-01-01

    There is little research literature on the conversion of lignocellulosic rich waste streams to ethanol, and even fewer have investigated both the technical aspects and environmental impacts together. This study assessed technical and environmental challenges of converting three lignocellulosic waste streams to ethanol: municipal solid waste (MSW), low grade mixed waste paper (MWP), and organic yard waste (YW). Experimental results showed high conversion yields for all three streams using suitable conversion methods. Environmental impacts are highly dependent on conversion technology, and process conditions used. Life cycle assessment results showed that both chemicals production and waste collection are important factors to be included within a waste-to-ethanol study. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. 40 CFR 62.14107 - Emission limits for air curtain incinerators.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and that combusts a fuel feed stream composed of 100 percent yard waste and no other municipal solid... level of up to 35 percent (6-minute average) is permitted during startup periods during the first 30...

  14. City of Columbia, Missouri - Clean Water Act Public Notice

    EPA Pesticide Factsheets

    The EPA is providing notice of a proposed Administrative Penalty Assessment against the City of Columbia, MO, regarding alleged violations at the City's Landfill and Yard Waste Compost Facility, located at 5700 Peabody Road, Columbia, Boone County, MO, 652

  15. National markets for organic waste-derived fertilizers and soil amendments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Logan, T.J.; Pierzynski, G.M.; Pepperman, R.E.

    1995-12-31

    The last decade has seen enormous growth in the U.S. in the recycling of organic waste materials like sewage sludge, manures, yard waste, solid waste and various industrial wastes. This has been prompted by real or perceived shortages of landfill capacity, state and federal regulations favoring beneficial use of organic wastes, and public support for recycling. Use of fertilizers and soil amendments derived from these wastes has been stimulated by favorable supply-side economics, a shift to organic/sustainable agriculture, and water quality concerns that favor slow-release nutrient sources. This paper summarizes the properties and beneficial use attributes of the various wastesmore » and their derived products, markets for these materials, and constraints/strategies for market penetration.« less

  16. A comparative study of two composts as filter media for the removal of gaseous reduced sulfur compounds (RSCs) by biofiltration: application at industrial scale.

    PubMed

    Hort, C; Gracy, S; Platel, V; Moynault, L

    2013-01-01

    This work presents the use of two composts as filter media for the treatment by biofiltration of odors emitted during the aerobic composting of a mixture containing sewage sludge and yard waste. The chemical analysis of the waste gas showed that the malodorous compounds at trace level were the reduced sulfur compounds (RSCs) which were dimethyl sulfide (Me(2)S), methanethiol (MeSH) and hydrogen sulfide (H(2)S). Laboratory tests for biofiltration treatment of RSCs were performed in order to compare the properties of two filter media, consisted of a mature compost with yard waste (YW) and a mixture of mature compost with sewage sludge and yard waste (SS/YW). The maximum elimination capacity (EC) values obtained with the YW mature compost as packing material were 12.5 mg m(-3)h(-1) for H(2)S, 7.9 mg m(-3)h(-1) for MeSH and 34 mg m(-3)h(-1) for Me(2)S, and the removal efficiency decreased in the order of: H(2)S>MeSH>Me(2)S. Moreover, the YW compost filter medium had a better behavior than the filter medium based on SS/YW in terms of acclimation of the microbial communities and moisture content. According to these results, a YW mature compost as packing material for an industrial biofilter were designed and this industrial biofilter was found effective under specified conditions (without inoculation and addition of water). The results showed that the maximum EC value of RSCs was 935 mg m(-3)h(-1) (100% removal efficiency, RE) for an inlet loads (IL) between 0 and 1000 mg m(-3)h(-1). Thus, YW compost medium was proven efficient for biofiltration of RSCs both at laboratory and industrial scale. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Great Lakes: Great Gardening.

    ERIC Educational Resources Information Center

    New York Sea Grant Inst., Albany, NY.

    This folder contains 12 fact sheets designed to improve the quality of gardens near the Great Lakes. The titles are: (1) "Your Garden and the Great Lakes"; (2) "Organic Gardening"; (3) "Fruit and Vegetable Gardening"; (4) "Composting Yard Wastes"; (5) "Herbicides and Water Quality"; (6)…

  18. Hazardous Waste Cleanup: Hess Corporation in Port Reading, New Jersey

    EPA Pesticide Factsheets

    The Hess Corporation Port Reading Refinery occupies approximately 210 acres on Cliff Road in an industrial waterfront area of Port Reading, New Jersey. The Conrail Port Reading Rail Yard is located to the north, the Arthur Kill shipping channel to the

  19. Vermicompost derived from different feedstocks as a plant growth medium.

    PubMed

    Warman, P R; Anglopez, M J

    2010-06-01

    This study determined feedstock effects on earthworm populations and the quality of resulting vermicomposts produced from different types of feedstocks using different vermicomposting durations. Feedstock combinations (Kitchen Paper Waste (KPW), Kitchen Yard Waste (KYW), Cattle Manure Yard Waste (CMY)), three durations of vermicomposting (45, 68 or 90 days), and two seed germination methods (with two concentrations of vermicompost) for radish, marigold and upland cress, served as the independent variables. The worms (Eisenia fetida) doubled their weight by day 68 in KPW and CMY vermicomposts and day 90 KPW vermicompost produced the greatest weight of worms. The direct seed germination method (seeding into soil or vermicompost-soil mixtures) indicated that KPW and KYW feedstocks decreased germination compared to the control, even in mature vermicompost. Seed germination was greater in the water extract method; however, most of the vermicompost extracts suppressed germination of the three seed species compared to the water controls. Vermicomposts from all three feedstocks increased leaf area and biomass compared to the control, especially in the 10% vermicompost:soil mix. Thus, seed germination and leaf area or plant biomass for these three species are contrasting vermicompost quality indicators. (c) 2010 Elsevier Ltd. All rights reserved.

  20. Superfund Record of Decision (EPA Region 3): Tyson Dump Number 1, Upper Merion Township, Montgomery County, PA. (Third remedial action), September 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-09-28

    The 4-acre Tyson Dump No. 1 site is an abandoned septic and chemical waste disposal area in Upper Merion Township, Montgomery County, Pennsylvania. The site consists of a series of abandoned unlined lagoons in a former sandstone quarry, and is bordered by unnamed tributaries to the Schuylkill River on the east and west, and a railroad switching yard to the north. Beyond the railroad yard is a floodplain/wetlands area and the Schuylkill River, which flows southeast toward Philadelphia. The river is the main source of drinking water in the area. From 1960 until 1973, the privately owned site was usedmore » for the disposal of liquid septic tank wastes, sludges, and chemical wastes that were hauled onsite in bulk tank trucks. The third ROD addresses OU3, the further remediation of the contaminated ground water that has migrated under the Schuylkill River. Additional ground water investigations will be conducted on the north side of the river, and based on the results, a fourth operable unit may be identified. The primary contaminants of concern affecting the ground water are VOCs including toluene and xylenes.« less

  1. Surface radiological investigations at White Wing Scrap Yard, Oak Ridge Reservation, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, J.K.; Rodriguez, R.E.; Uziel, M.S.

    1991-09-01

    A surface radiological scoping survey of accessible areas at the White Wing Scrap Yard (Waste Area Grouping 11 (WAG 11)) was conducted intermittently from December 1989 through July 1991 by members of the Measurement Applications and Development Group, Health and Safety Research Division, Oak Ridge National Laboratory (ORNL) at the request of Environmental Restoration Program personnel at ORNL. The White Wing Scrap Yard is an estimated 30-acre, predominately wooded area located on the western edge of East Fork Ridge in the McNew Hollow area on the US Department of Energy's Oak Ridge Reservation. The scrap yard was formerly used formore » aboveground storage of contaminated material (e.g., steel tanks, metal, glass, concrete, and miscellaneous industrial trash) from the Oak Ridge K-25 Site, Oak Ridge Y-12 Plant, and ORNL. The purposes of this cursory investigation were (1) to provide an updated contamination status of the site by locating and interpreting the presence, nature, and extent of surface radiological contamination and (2) to provide a basis for the formulation of interim corrective action to limit human exposures to radioactivity and minimize the potential for contaminant dispersion. 13 refs., 17 figs., 5 tabs.« less

  2. All hazardous waste politics is local: Grass-roots advocacy and public participation in siting and cleanup decisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowry, R.C.

    1998-12-31

    The combined effects of federalism and interest group pluralism pose particularly difficult problems for hazardous waste siting and cleanup decisions. Most national environmental groups have only limited involvement in local hazardous waste politics, while local grass-roots advocates have very different interests and sometimes are pitted against one another. Both the Environmental protection Agency and the Department of energy recently have begun to use site-specific citizen advisory boards at cleanup sites. This approach appears to improve communications at some sites, but does not address the issues of ``not in my back yard`` politics and alleged inequitable exposure to hazardous wastes.

  3. Composting: Fast 2.

    ERIC Educational Resources Information Center

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    Composting is a way of using organic wastes from yards and kitchens to help plants grow. This book discusses how composting happens in nature, the classification of composting methods, and their characteristics. Examples of containers for aerobic/anaerobic decomposition are introduced along with sample activities. The process of aerobic/anaerobic…

  4. Enrichment of antibiotic resistance genes in soil receiving composts derived from swine manure, yard wastes, or food wastes, and evidence for multiyear persistence of swine Clostridium spp.

    PubMed

    Scott, Andrew; Tien, Yuan-Ching; Drury, Craig F; Reynolds, W Daniel; Topp, Edward

    2018-03-01

    The impact of amendment with swine manure compost (SMC), yard waste compost (YWC), or food waste compost (FWC) on the abundance of antibiotic resistance genes in soil was evaluated. Following a commercial-scale application of the composts in a field experiment, soils were sampled periodically for a decade, and archived air-dried. Soil DNA was extracted and gene targets quantified by qPCR. Compared with untreated control soil, all 3 amendment types increased the abundance of gene targets for up to 4 years postapplication. The abundance of several gene targets was much higher in soil amended with SMC than in soil receiving either YWC or FWC. The gene target ermB remained higher in the SMC treatment for a decade postapplication. Clostridia were significantly more abundant in the SMC-amended soil throughout the decade following application. Eight percent of Clostridium spp. isolates from the SMC treatment carried ermB. Overall, addition of organic amendments to soils has the potential to increase the abundance of antibiotic resistance genes. Amendments of fecal origin, such as SMC, will in addition entrain bacteria carrying antibiotic resistance genes. Environmentally recalcitrant clostridia, and the antibiotic resistance genes that they carry, will persist for many years under field conditions following the application of SMC.

  5. 7 CFR 1450.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... yard waste; diesel-equivalent fuel derived from renewable biomass including vegetable oil and animal... CCC. Equivalent plan means a plan approved by a State or other State agency or government entity that... required for non-woody perennial crops and woody perennial crops, as specified in a producer contract under...

  6. Greening the Toronto District School Board.

    ERIC Educational Resources Information Center

    Root, Emily

    2002-01-01

    The Toronto District School Board (Ontario) established a department of environmental education to lighten the school board's impact on the environment and to increase ecological literacy among students. School programs have been developed in the areas of eco-literacy, energy conservation, waste management, and school yard greening. One program…

  7. Fermentation of cucumbers brined with calcium chloride instead of sodium chloride

    USDA-ARS?s Scientific Manuscript database

    Generation of waste water containing sodium chloride from cucumber fermentation tank yards could be eliminated if cucumbers were fermented in brines that did not contain this salt. To determine if this is feasible, cucumbers were fermented in brines that contained only calcium chloride to maintain f...

  8. TREATMENT OF ARSENIC AND METALS IN GROUND WATER USING A COMPOST/ZVI PRB

    EPA Science Inventory

    A pilot permeable reactive barrier (PRB) consisting of a mixture of 30% yard waste compost, 20% zero-valent iron (ZVI), 5% limestone and 45% pea gravel by volume was installed at a former phosphate fertilizer manufacturing facility in Charleston, S.C. in September 2002. The pilo...

  9. 101 Things You Can Do to Help Save Animals and Animal Habitats.

    ERIC Educational Resources Information Center

    Clearing, 1988

    1988-01-01

    The improper disposal of toxic or non-biodegradable wastes contributes to the problems of pollution, habitat destruction, and animal extinction. This list suggests ways that individuals can reduce their contribution to these problems in the home, yard, car, business, on vacation, and when shopping. (CW)

  10. Closure Report for Corrective Action Unit 166: Storage Yards and Contaminated Materials, Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2009-08-01

    Corrective Action Unit (CAU) 166 is identified in the Federal Facility Agreement and Consent Order (FFACO) as 'Storage Yards and Contaminated Materials' and consists of the following seven Corrective Action Sites (CASs), located in Areas 2, 3, 5, and 18 of the Nevada Test Site: CAS 02-42-01, Condo Release Storage Yd - North; CAS 02-42-02, Condo Release Storage Yd - South; CAS 02-99-10, D-38 Storage Area; CAS 03-42-01, Conditional Release Storage Yard; CAS 05-19-02, Contaminated Soil and Drum; CAS 18-01-01, Aboveground Storage Tank; and CAS 18-99-03, Wax Piles/Oil Stain. Closure activities were conducted from March to July 2009 according tomore » the FF ACO (1996, as amended February 2008) and the Corrective Action Plan for CAU 166 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2007b). The corrective action alternatives included No Further Action and Clean Closure. Closure activities are summarized. CAU 166, Storage Yards and Contaminated Materials, consists of seven CASs in Areas 2, 3, 5, and 18 of the NTS. The closure alternatives included No Further Action and Clean Closure. This CR provides a summary of completed closure activities, documentation of waste disposal, and confirmation that remediation goals were met. The following site closure activities were performed at CAU 166 as documented in this CR: (1) At CAS 02-99-10, D-38 Storage Area, approximately 40 gal of lead shot were removed and are currently pending treatment and disposal as MW, and approximately 50 small pieces of DU were removed and disposed as LLW. (2) At CAS 03-42-01, Conditional Release Storage Yard, approximately 7.5 yd{sup 3} of soil impacted with lead and Am-241 were removed and disposed as LLW. As a BMP, approximately 22 ft{sup 3} of asbestos tile were removed from a portable building and disposed as ALLW, approximately 55 gal of oil were drained from accumulators and are currently pending disposal as HW, the portable building was removed and disposed as LLW, and accumulators, gas cylinders, and associated debris were removed and are currently pending treatment and disposal as MW. (3) At CAS 05-19-02, Contaminated Soil and Drum, as a BMP, an empty drum was removed and disposed as sanitary waste. (4) At CAS 18-01-01, Aboveground Storage Tank, approximately 165 gal of lead-impacted liquid were removed and are currently pending disposal as HW, and approximately 10 gal of lead shot and 6 yd{sup 3} of wax embedded with lead shot were removed and are currently pending treatment and disposal as MW. As a BMP, approximately 0.5 yd{sup 3} of wax were removed and disposed as hydrocarbon waste, approximately 55 gal of liquid were removed and disposed as sanitary waste, and two metal containers were grouted in place. (5) At CAS 18-99-03, Wax Piles/Oil Stain, no further action was required; however, as a BMP, approximately l.5 yd{sup 3} of wax were removed and disposed as hydrocarbon waste, and one metal container was grouted in place.« less

  11. Synthetic fuel for imitation of municipal solid waste in experimental studies of waste incineration.

    PubMed

    Thipse, S S; Sheng, C; Booty, M R; Magee, R S; Dreizin, E L

    2001-08-01

    Synthetic fuel is prepared to imitate municipal solid waste (MSW) in experimental studies of incineration processes. The fuel is composed based on the Environmental Protection Agency reports on the materials contained in MSW. Uniform synthetic fuel pellets are prepared using available and inexpensive components including newsprint, hardwood mulch, low density polyethylene, iron, animal feed, sand, and water to imitate paperbound, wood, yard trimming, plastic, metal, food wastes, and other materials in MSW. The synthetic fuel preparation procedure enables one to reproduce and modify the fuel for a wide range of experiments in which the mechanisms of waste incineration are addressed. The fuel is characterized using standard ASTM tests and it is shown that its parameters, such as combustion enthalpy, density, as well as moisture, ash and fixed carbon contents are adequate for the representation of municipal solid waste. In addition, chlorine, nitrogen, and sulfur contents of the fuel are shown to be similar to those of MSW. Experiments are conducted in which the synthetic fuel is used for operation of a pilot-scale incinerator research facility. Steady-state temperature operation regimes are achieved and reproduced in these experiments. Thermodynamic equilibrium flame conditions are computed using an isentropic one-dimensional equilibrium code for a wide range of fuel/air ratios. The molecular species used to represent the fuel composition included cellulose, water, iron, polyethylene, methanamine, and silica. The predicted concentrations of carbon monoxide, nitric oxides, and oxygen in the combustion products are compared with the respective experimental concentrations in the pilot-scale incinerator exhaust.

  12. Superfund Record of Decision (EPA Region 5): Summit National Liquid Disposal Service, Deerfield, OH. (First remedial action), (Amendment), November 1990. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The 11.5-acre Summit National Liquid Disposal Service site is a former liquid waste disposal facility in rural Deerfield Township, Ohio. The site contains two ponds, an inactive incinerator, and several vacant buildings. Surrounding the site are several residences, two landfills, light industries, and farmland. From 1973 to 1978, Summit National operated a solvent recycling and waste disposal facility onsite. The Record of Decision (ROD) amends a 1988 ROD that provided for remediation of contaminated soil, sediment, debris, ground water, and surface water. In both the 1990 proposed remedy for the ROD amendment and the 1988 ROD, the remedy for themore » most highly contaminated soil and sediment is excavation and treatment. The amended remedial action for the site includes expanding site boundaries to include contaminated areas along the site perimeters; excavating and incinerating onsite 24,000 cubic yards of soil excavated to a depth of 2 feet, 4,000 cubic yards of sediment from the site perimeter, drainage ditches and offsite ponds, and 900 to 1,600 buried drums.« less

  13. Mixtures of a coal combustion by-product and composted yard wastes for use as soil substitutes and amendments. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckert, D.J.; McCoy, E.L.; Danneberger, T.K.

    Mixtures of coal combustion by-product (CCBP) and yard waste compost (with and without sand), and mixtures of CCBP and soil, were evaluated for use as soil substitutes and amendments for production of container-grown ornamental shrubs and trees, and for establishment and production of forage-groundcover species. Species evaluated were azalea (Rhododendron spp.), burning bush (Euonymous alatus), red maple (Acer rubrum), yew (Taxus spp.), tall fescue (Festuca arundi nacea, cv. {open_quotes}Chesapeake{close_quotes}), alfalfa, and Kentucky bluegrass (Poa pratensis L., cv. {open_quotes}Bronco{close_quotes}). All ornamental species failed to grow when planted in CCBP/compost mixtures when the CCBP concentration was greater than 30 percent by volume.more » Plant toxicity due to high concentrations of soluble salts and boron was responsible for the poor plant performance. When CCBP was used as a soil amendment at concentrations less than 30 percent, growth of tall fescue and Kentucky bluegrass was not affected by the mixture, and alfalfa yield increased at CCBP mixtures up to 20 percent.« less

  14. 76 FR 50757 - Notice of Lodging of a Consent Decree Under the Clean Water Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-16

    ... March 2023 by completing sewer separation projects and upgrades at an approximate cost of $4.2 million... and (3) establish and operate a yard waste pick-up and recycling program for Elkins' residents as a Supplemental Environmental Project (``SEP''). The Department of Justice will receive for a period of thirty (30...

  15. 40 CFR 60.51a - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... specified in § 60.58a(h)(6). MWC acid gases means all acid gases emitted in the exhaust gases from MWC units... or geometric mean (as specified in § 60.58a (e), (g), or (h) as applicable) of all hourly emission... section) of the combustor. Yard waste means grass, grass clippings, bushes, shrubs, and clippings from...

  16. 40 CFR 60.51a - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... specified in § 60.58a(h)(6). MWC acid gases means all acid gases emitted in the exhaust gases from MWC units... or geometric mean (as specified in § 60.58a (e), (g), or (h) as applicable) of all hourly emission... section) of the combustor. Yard waste means grass, grass clippings, bushes, shrubs, and clippings from...

  17. Cover crop frequency and compost effects on a legume-rye cover crop during 8 years of organic vegetables

    USDA-ARS?s Scientific Manuscript database

    Organic matter inputs from compost or cover crops (CC) are important to maintain or improve soil quality, but their impact in high-value vegetable production systems are not well understood. Therefore, we evaluated the effects of CC frequency (every winter versus every 4th winter) and yard-waste co...

  18. Heating value prediction for combustible fraction of municipal solid waste in Semarang using backpropagation neural network

    NASA Astrophysics Data System (ADS)

    Khuriati, Ainie; Setiabudi, Wahyu; Nur, Muhammad; Istadi, Istadi

    2015-12-01

    Backpropgation neural network was trained to predict of combustible fraction heating value of MSW from the physical composition. Waste-to-Energy (WtE) is a viable option for municipal solid waste (MSW) management. The influence of the heating value of municipal solid waste (MSW) is very important on the implementation of WtE systems. As MSW is heterogeneous material, direct heating value measurements are often not feasible. In this study an empirical model was developed to describe the heating value of the combustible fraction of municipal solid waste as a function of its physical composition of MSW using backpropagation neural network. Sampling process was carried out at Jatibarang landfill. The weight of each sorting sample taken from each discharged MSW vehicle load is 100 kg. The MSW physical components were grouped into paper wastes, absorbent hygiene product waste, styrofoam waste, HD plastic waste, plastic waste, rubber waste, textile waste, wood waste, yard wastes, kitchen waste, coco waste, and miscellaneous combustible waste. Network was trained by 24 datasets with 1200, 769, and 210 epochs. The results of this analysis showed that the correlation from the physical composition is better than multiple regression method .

  19. Municipal solid waste flow and waste generation characteristics in an urban--rural fringe area in Thailand.

    PubMed

    Hiramatsu, Ai; Hara, Yuji; Sekiyama, Makiko; Honda, Ryo; Chiemchaisri, Chart

    2009-12-01

    In the urban-rural fringe of the Bangkok Metropolitan Region, rapid urbanization is creating a land-use mixture of agricultural fields and residential areas. To develop appropriate policies to enhance recycling of municipal solid waste (MSW), current MSW management was investigated in the oboto (local administrative district) of Bang Maenang in Nonthaburi Province, adjoining Bangkok. The authors conducted a structural interview survey with waste-related organizations and local residents, analysed household waste generation, and performed global positioning system (GPS) tracking of municipal garbage trucks. It was found that MSW was collected and treated by local government, private-sector entities, and the local community separately. Lack of integrated management of these entities complicated waste flow in the study area, and some residences were not served by MSW collection. Organic waste, such as kitchen garbage and yard waste, accounted for a large proportion of waste generation but was underutilized. Through GPS/GIS analysis, the waste collection rate of the generated waste amount was estimated to be 45.5- 51.1% of total generation.

  20. Effect of Meloidogyne arenaria and Mulch Type on Okra in Microplot Experiments.

    PubMed

    Ritzinger, C H; McSorley, R; Gallaher, R N

    1998-12-01

    The effects of perennial peanut (Arachis glabrata) hay, an aged yard-waste compost (mainly woodchips), and a control treatment without amendment were determined on two population levels of root-knot (Melaidogyne arenaria) nematode over three consecutive years in field microplots. Okra (Hibiscus esculentus, susceptible to the root-knot nematode) and a rye (Secale cereale) cover crop (poor nematode host) were used in the summer and winter seasons, respectively. The organic amendment treatments affected plant growth parameters. In the first year, okra yields were greatest in peanut-amended plots. Yield differences with amendment treatment diminished in the second and third years. Okra plant height, total fruit weight, and fruit number were greater with the lower population level of the root-knot nematode. Residual levels of nutrients in soil were greater where root-knot nematode levels and damage were higher and plant growth was poor. Nutrient levels affected the growth of a subsequent rye cover crop.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Corrective Action Unit (CAU) 390 consists four Corrective Action Sites (CASs) located in Areas 9, 10, and 12 of the Nevada Test Site. The closure activities performed at the CASs include: (1) CAS 09-99-03, Wax, Paraffin: 2 cubic yards of drilling polymer was removed on June 20,2005, and transported to the Area 9 Landfill for disposal. (2) CAS 10-99-01, Epoxy Tar Spill: 2 cubic feet of asphalt waste was removed on June 20,2005, and transported to the Area 9 Landfill for disposal. (3) CAS 10-99-03, Tar Spills: 3 cubic yards of deteriorated asphalt waste was removed on June 20,2005, andmore » transported to the Area 9 Landfill for disposal. (4) CAS 12-25-03, Oil Stains (2); Container: Approximately 16 ounces of used oil were removed from ventilation equipment on June 28,2005, and recycled. One CAS 10-22-19, Drums, Stains, was originally part of CAU 390 but was transferred out of CAU 390 and into CAU 550, Drums, Batteries, and Lead Materials. The transfer was approved by the Nevada Division of Environmental Protection on August 19,2005, and a copy of the approval letter is included in Appendix D of this report.« less

  2. 2-undecanone and 2-tridecanone in field-grown onion.

    PubMed

    Antonious, George F

    2013-01-01

    A field study was conducted to investigate the impact of soil amendments on concentrations of two volatile organic compounds, 2-undecanone and 2-tridecanone, in onion bulbs. The soil in five plots was mixed with sewage sludge, five plots were mixed with yard waste compost, five plots were mixed with laying hen manure each at 15 t acre(-1), and five unamended plots that never received soil amendments were used for comparison purposes. Plots (n = 20) were planted with onion, Allium cepa L. var. Super Star-F1 bulbs. Gas chromatographic/mass spetrometric (GC/MS) analyses of mature onion bulbs crude extracts revealed the presence of two major fragment ions that correspond to 2-undecanone and 2-tridecanone. Soil amended with yard waste compost enhanced 2-undecanone and 2-tridecanone production by 31 and 59%, respectively. Soil amended with chicken manure enhanced 2-undecanone and 2-tridecanone production by 28 and 43%, respectively. Concentrations of 2-undecanone and 2-tridecanone were lowest in onion bulbs of plants grown in sewage sludge and unamended soil, respectively. The increased concentrations of 2-undecanone and 2-tridecanone in onion bulbs may provide a protective character against insect and spider mite attack in field grown onions.

  3. Superfund Record of Decision (EPA Region 5): South Andover Salvage Yards, Operable Unit 1, Anoka County, Andover, MN. (Second remedial action), (amendment), June 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The 50-acre South Andover site is composed of several privately owned parcels of land near Minneapolis in Anoka County, Minnesota. There are several source areas where former activities included drum storage, waste storage, and waste burning. Solid and liquid chemical waste dumping and open pit burning of solvents occurred during the 1960's and 1970's. Investigations showed that drum storage and chemical waste disposal sites were partially obscured by auto salvage operations and more than 3 million waste tires. The ROD amendment changes the 1988 ROD for ground water based on current data from a 1990 Design Investigation. The primary contaminantsmore » of concern affecting the ground water are VOCs, including acetone, ethyl benzene, methylchloride, PCE, TCE, toluene; and metals, including arsenic, chromium, and lead.« less

  4. RCRA Sustainable Materials Management Information

    EPA Pesticide Factsheets

    This asset includes a broad variety of documents, descriptive data, technical analyses and guidance materials relative to voluntary improvements in resource conservation, the beneficial use of sustainable materials and the management of non-hazardous wastes and materials. Included in this asset are participant information and outreach materials of various voluntary programs relating to better materials and waste management programs. An example is the WasteWise program and Sustainable Materials Management (SMM) Challenges, which help organizations and businesses apply sustainable materials management practices to reduce municipal and select industrial wastes. Also included in this asset are guidance materials to assist municipalities in recycling and reuse of municipal solid waste, including diverting materials to composting, and the use of conversion methods such as anaerobic digestion. Another component are the data necessary to compile reports on the characterization of municipal solid waste (including such waste streams as food waste, yard and wood waste, discarded electronics, and household non-hazardous waste), the recycled content of manufactured goods, and other analyses performed using such tools as the Waste Assessment Reduction Model (WARM).For industrial non-hazardous waste, this asset includes guidance and outreach materials on industrial materials recycling and waste minimization. Finally, this asset includes research analyses on sustainable materia

  5. An integrated analytical framework for quantifying the LCOE of waste-to-energy facilities for a range of greenhouse gas emissions policy and technical factors.

    PubMed

    Townsend, Aaron K; Webber, Michael E

    2012-07-01

    This study presents a novel integrated method for considering the economics of waste-to-energy (WTE) facilities with priced greenhouse gas (GHG) emissions based upon technical and economic characteristics of the WTE facility, MSW stream, landfill alternative, and GHG emissions policy. The study demonstrates use of the formulation for six different policy scenarios and explores sensitivity of the results to ranges of certain technical parameters as found in existing literature. The study shows that details of the GHG emissions regulations have large impact on the levelized cost of energy (LCOE) of WTE and that GHG regulations can either increase or decrease the LCOE of WTE depending on policy choices regarding biogenic fractions from combusted waste and emissions from landfills. Important policy considerations are the fraction of the carbon emissions that are priced (i.e. all emissions versus only non-biogenic emissions), whether emissions credits are allowed due to reducing fugitive landfill gas emissions, whether biogenic carbon sequestration in landfills is credited against landfill emissions, and the effectiveness of the landfill gas recovery system where waste would otherwise have been buried. The default landfill gas recovery system effectiveness assumed by much of the industry yields GHG offsets that are very close to the direct non-biogenic GHG emissions from a WTE facility, meaning that small changes in the recovery effectiveness cause relatively larger changes in the emissions factor of the WTE facility. Finally, the economics of WTE are dependent on the MSW stream composition, with paper and wood being advantageous, metal and glass being disadvantageous, and plastics, food, and yard waste being either advantageous or disadvantageous depending upon the avoided tipping fee and the GHG emissions price. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Response of soil microorganisms to radioactive oil waste: results from a leaching experiment

    NASA Astrophysics Data System (ADS)

    Galitskaya, P.; Biktasheva, L.; Saveliev, A.; Ratering, S.; Schnell, S.; Selivanovskaya, S.

    2015-06-01

    Oil wastes produced in large amounts in the processes of oil extraction, refining, and transportation are of great environmental concern because of their mutagenicity, toxicity, high fire hazardousness, and hydrophobicity. About 40% of these wastes contain radionuclides; however, the effects of oil products and radionuclides on soil microorganisms are frequently studied separately. The effects on various microbial parameters of raw waste containing 575 g of total petroleum hydrocarbons (TPH) kg-1 waste, 4.4 of 226Ra, 2.8 of 232Th, and 1.3 kBq kg-1 of 40K and its treated variant (1.6 g kg-1 of TPH, 7.9 of 226Ra, 3.9 of 232Th, and 183 kBq kg-1 of 40K) were examined in a leaching column experiment to separate the effects of hydrocarbons from those of radioactive elements. The raw waste sample (H) was collected from tanks during cleaning and maintenance, and a treated waste sample (R) was obtained from equipment for oil waste treatment. Thermal steam treatment is used in the production yard to reduce the oil content. The disposal of H waste samples on the soil surface led to an increase in the TPH content in soil: it became 3.5, 2.8, and 2.2 times higher in the upper (0-20 cm), middle (20-40 cm), and lower (40-60cm) layers, respectively. Activity concentrations of 226Ra and 232Th increased in soil sampled from both H- and R- columns in comparison to their concentrations in control soil. The activity concentrations of these two elements in samples taken from the upper and middle layers were much higher for the R-column compared to the H-column, despite the fact that the amount of waste added to the columns was equalized with respect to the activity concentrations of radionuclides. The H waste containing both TPH and radionuclides affected the functioning of the soil microbial community, and the effect was more pronounced in the upper layer of the column. Metabolic quotient and cellulase activity were the most sensitive microbial parameters as their levels were changed 5-1.4 times in comparison to control ones. Changes in soil functional characteristics caused by the treated waste containing mainly radionuclides were not observed. PCR-SSCP (polymerase chain reaction - single strand conformation polymorphism) analysis followed by MDS (metric multidimensional scaling) and clustering analysis revealed that the shifts in microbial community structure were affected by both hydrocarbons and radioactivity. Thus, molecular methods permitted to reveal the effects on soil microbial community not only from hydrocarbons, which significantly altered functional characteristics of soil microbiome, but also from radioactive elements.

  7. Remedial Investigation Work Plan for Upper East Fork Poplar Creek Operable Unit 3 at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Environmental Restoration Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-08-01

    Upper East Fork Popular Creek Operable Unit 3 (UEFPC OU 3) is a source term OU composed of seven sites, and is located in the western portion of the Y-12 Plant. For the most part, the UEFPC OU 3 sites served unrelated purposes and are geographically removed from one another. The seven sites include the following: Building 81-10, the S-2 Site, Salvage Yard oil storage tanks, the Salvage Yard oil/solvent drum storage area, Tank Site 2063-U, the Salvage Yard drum deheader, and the Salvage Yard scrap metal storage area. All of these sites are contaminated with at least one ormore » more hazardous and/or radioactive chemicals. All sites have had some previous investigation under the Y-12 Plant RCRA Program. The work plan contains summaries of geographical, historical, operational, geological, and hydrological information specific to each OU 3 site. The potential for release of contaminants to receptors through various media is addressed, and a sampling and analysis plan is presented to obtain objectives for the remedial investigation. Proposed sampling activities are contingent upon the screening level risk assessment, which includes shallow soil sampling, soil borings, monitoring well installation, groundwater sampling, and surface water sampling. Data from the site characterization activities will be used to meet the above objectives. A Field Sampling Investigation Plan, Health and Safety Plan, and Waste Management Plan are also included in this work plan.« less

  8. Performance of five Montreal West Island home composters.

    PubMed

    Adhikari, Bijaya K; Trémier, Anne; Barrington, Suzelle

    2012-01-01

    Even if home composting can eliminate municipal organic waste collection, handling and treatment costs, its compost quality requires investigation outside the laboratory. A study was thus conducted to evaluate the influence of the following management practices on the compost quality produced by five backyards home composters in Montreal West Island from June to October 2010: the type and backyard location of the home composter (HC), and the rate and type of organic waste (OW) fed into the home composter. The parameters monitored were compost temperature and final characteristics including trace elements and pathogens. For all HC compost, maximum but not necessarily thermophilic temperatures were highly probable within one week of adding more than 10 kg of OW composed of equal volumes of food waste (FW) and yard trimmings (YT). Top and bottom HC perforations enhanced convective aeration but concentrated OW decomposition within the bottom layer. Fed an equal volume of FW and YT, the final HC compost had a dry and organic matter content exceeding 30%, and 50%, respectively, and a total nitrogen, phosphorous and potassium level of 2, 1 and 3% on a dry matter basis, representing a good quality soil amendment. Clean OW feeding resulted in compost respecting Canadian and European regulations for Escherichia coli and Salmonella, irrespective of the temperature regime. For trace elements, regulatory limits may be exceeded when the home composter is fed ashes and soil. Homeowners must also be careful when applying pesticides to their lawns and gardens and then feeding the residues to the home composter.

  9. Evaluating the dynamical characteristics of particle matter emissions in an open ore yard with industrial operation activities.

    PubMed

    Cong, X C; Yang, G S; Qu, J H; Dai, M X

    2016-11-01

    A study to investigate the dynamical characteristics of particle matter emissions in a working open yard is conducted in Caofeidian Port of Hebei Province, China. The average diurnal concentrations of the total suspended particulate (TSP) matter and respirable particulate matter (PM 10 and PM 5 ) are monitored during the field measurement campaign. Sampling is performed at a regular interval at 8 monitoring stations in the yard with normal industrial activities. The average TSP, PM 10 and PM 5 concentrations range from 285 to 568, 198 to 423 and 189 to 330 μg.m-3 in the yard, respectively. The linear regression correlation coefficient of TSP/PM 10 and TSP/PM 5 is 0.95±0.01 and 0.88±0.02, respectively.By using the Spearman correlation method, the wind speed and relative humidity are both weakly correlated with the PM 10 and PM 5 concentrations according to the measurements. In addition, industrial operation activities, such as vehicular traffic in the yard and the loading time of stackers, are significantly positively correlated with the PM concentration. Using the multivariate regression method, the main parameters influencing the TSP concentration variations are integratedly analysed. The traffic volume is found to be a significant predictor of TSP concentration variation, with the smallest P value (P<0.05).To understand the dynamical characteristics of particle emissions in the yard, the emissions from the truck transports, that is, from unpaved haul roads and from the loading process, are established. Then, the dynamical emission factor (EF D ) based on the industrial activities in the yard is proposed. The dynamical emissions average 5.25x10 5 kg.year -1 and EF D is evaluated to be 0.29 kg.(ton.day) -1 during the measurement period. These outcomes have meaningful implications not only for understanding the dynamical characteristics of particle emissions in the working stockyard but also for implementing effective control measures at appropriate sites in the harbour area.

  10. Wealth distribution under Yard-Sale exchange with proportional taxes

    NASA Astrophysics Data System (ADS)

    Bustos-Guajardo, R.; Moukarzel, Cristian F.

    2016-03-01

    Recent analysis of a Yard-Sale (YS) exchange model supplemented with redistributive proportional taxation suggested an asymptotic behavior P(w)˜1/wμ for the wealth distribution, with a parameter-dependent exponent μ. Revisiting this problem, it is here shown analytically, and confirmed by extensive numerical simulation, that the asymptotic behavior of P(w) is not power-law but rather a Gaussian. When taxation is weak, we furthermore show that a restricted-range power-law behavior appears for wealths around the mean value. The corresponding power-law exponent equals 3/2 when the return distribution has zero mean.

  11. Harvesting southern pines with taproots is economic way to boost tonnage per acre 20 percent

    Treesearch

    P. Koch

    1977-01-01

    At the Southern Forest Experiment Station, we've been trying to extend the pulpwood resource by bringing more of each pine tree to the mill yard. The taproot of a 15- to 30-year-old southern pine weighs about 20% as much as the merchantable stem (Table I). Harvesting and pulping this wasted material would greatly increase pulpwood tonnage yield per acre. But is it...

  12. Harvesting southern pines with taproots is economic way to boost tonnage per acre 20 percent.

    Treesearch

    P. Koch

    1977-01-01

    At the Southern Forest Experiment Station, we've been trying to exten the pulpwood resource by bringing more of each pine tree to the mill yard. The taproot of a 15- to 30-year-old southern pine weighs about 20% as much as the merchantable stem (Table 1). Harvesting and pulping this wasted material would greatly increase pulpwood tonnage yield per acre. But is it...

  13. Sediment characteristics and configuration within three dam impoundments on the Kalamazoo River, Michigan, 2000

    USGS Publications Warehouse

    Rheaume, S.J.; Rachol, C.M.; Hubbell, D.L.; Simard, Andreanne

    2002-01-01

    The removal of the remnants of three hydroelectric dams on the Kalamazoo River near Plainwell, Otsego, and Allegan, Michigan, has been proposed. The benefits of this removal include returning the Kalamazoo River to its pre-dam flow, increasing recreational use and safety on the river, and improving aquatic habitat. The U.S. Environmental Protection Agency has designated this reach of the Kalamazoo River as a Federal Superfund site because of the historical discharge of papermill waste containing polychlorinated biphenyls. Much of this waste material remains concentrated in organic sediment and kaolinite clay deposited upstream from the three dam foundations. Sediment containing up to 150 milligrams per kilogram polychlorinated biphenyls could move if dam foundations are removed; therefore, it is necessary to estimate the characteristic and configuration of the sediment before work begins. Data collected from augered sections and sediment cores show that impoundment sediments were deposited in two distinctly different sedimentary environments. Interbedded lacustrine sediments that overlie the pre-dam channel surface consist of organic-rich silt and clay, fine to medium sand, and some gravel. These materials were deposited in a repetitive, cyclic fashion related to former stream velocities when the impoundment water levels were 5-10 feet higher. Lowering of these water levels and demolition of the superstructures of these dams resulted in erosion of much of these instream lacustrine sediments and subsequent deposition of coarse-grained alluvium in the impounded channel behind the remaining dam foundations. The composite thicknesses of the lacustrine deposits and overlying alluvium was determined from sediment cores collected from each impoundment. The volume of instream sediment contained in each impoundment is estimated to be about 77,600 cubic yards at the Plainwell impoundment; 268,900 cubic yards at the Otsego impoundment; and 1,192,600 cubic yards at the Trowbridge impoundment. Estimates do not include bank or flood-plain deposits.

  14. Environmental assessment for the Plating Shop Replacement, Y-12 Plant, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-03-01

    The existing of Y-12 Plant Plating Shop provides vital support functions for the US Department of Energy (DOE) Defense Programs operations. In addition to weapon component plating, the facility performs other plating services to support existing operations for the Y-12 Plant, other DOE facilities, and other federal agencies. In addition, the facility would also provide essential deplating services for weapons reclamation and teardown. The existing Y-12 Plant Plating Shop is presently located in a structure which is rapidly deteriorating and obsolete. The existing building structure was originally designed to house a steam plant, not chemical plating operations. As such, vaporsmore » from plating operations have deteriorated the structure to a point where a new facility is needed for continued safe operations. The potential environmental impacts of the proposed action was anticipated to be minimal and would affect no environmentally sensitive areas. Some short-term construction- and demolition-related effects would occur in an already highly industrialized setting. These include temporarily disturbing 72,000 square feet of land for the new plating shop and related site preparation activities, constructing a permanent building on part of the area, and using 80 construction personnel over a period of 18 months for site preparation and construction. Demolition effects vary depending on the environmentally suitable option selected, but they could involve as much as 262 cubic yards of concrete rubble and approximately 1600 cubic yards of soil disposed as waste. Either 1600 cubic yards of fresh soil or 1850 yards of clay and fresh soil could be required. Soil erosion would be minimal. Approximately 20 construction personnel would be involved for 12 months in demolition activities.« less

  15. Railroad Classification Yard Technology Manual. Volume I : Yard Design Methods

    DOT National Transportation Integrated Search

    1981-02-01

    This volume documents the procedures and methods associated with the design of railroad classification yards. Subjects include: site location, economic analysis, yard capacity analysis, design of flat yards, overall configuration of hump yards, hump ...

  16. Repeated compost application effects on phosphorus runoff in the Virginia Piedmont.

    PubMed

    Spargo, John T; Evanylo, Gregory K; Alley, Marcus M

    2006-01-01

    Increasing amounts of animal and municipal wastes are being composted before land application to improve handling and spreading characteristics, and to reduce odor and disease incidence. Repeated applications of composted biosolids and manure to cropland may increase the risk for P enrichment of agricultural runoff. We conducted field research in 2003 and 2004 on a Fauquier silty clay loam (Ultic Hapludalfs) to compare the effects of annual (since 1999) applications of composted and uncomposted organic residuals on P runoff characteristics. Biosolids compost (BSC), poultry litter-yard waste compost (PLC), and uncomposted poultry litter (PL) were applied based on estimated plant-available N. A commercial fertilizer treatment (CF) and an unamended control treatment (CTL) were also included. Corn (Zea mays L.) and a cereal rye (Secale cereal L.) cover crop were planted each year. We applied simulated rainfall in fall 2004 and analyzed runoff for dissolved reactive P (DRP), total dissolved P (TDP), total P (TP), total organic C (TOC), and total suspended solids (TSS). End of season soil samples were analyzed for Mehlich-3 P (M3P), EPA 3050 P (3050P), water soluble P (WSP), degree of P saturation (DPS), soil C, and bulk density. Compost treatments significantly increased soil C, decreased bulk density, and increased M3P, 3050P, WSP, and DPS. The concentration of DRP, TDP, and TP in runoff was highest in compost treatments, but the mass of DRP and TDP was not different among treatments because infiltration was higher and runoff lower in compost-amended soil. Improved soil physical properties associated with poultry litter-yard waste compost application decreased loss of TP and TSS.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    In 1990, the Lower Savannah Council of Governments (LSCOG) began dialogue with the United States Department of Energy (DOE) regarding possibilities for cooperation and coordination of solid waste management practices among the local governments and the Savannah River Site. The Department of Energy eventually awarded a grant to the Lower Savannah Council of Governments for the development of a study, which was initiated on March 5, 1992. After careful analysis of the region`s solid waste needs, this study indicates a network approach to solid waste management to be the most viable. The network involves the following major components: (1) Ruralmore » Collection Centers, designed to provide convenience to rural citizens, while allowing some degree of participation in recycling; (2) Rural Drop-Off Centers, designed to give a greater level of education and recycling activity; (3) Inert landfills and composting centers, designed to reduce volumes going into municipal (Subtitle D) landfills and produce useable products from yard waste; (4) Transfer Stations, ultimate landfill disposal; (5) Materials Recovery Facilities, designed to separate recyclables into useable and sellable units, and (6) Subtitle D landfill for burial of all solid waste not treated through previous means.« less

  18. Estimation of waste component-specific landfill decay rates using laboratory-scale decomposition data.

    PubMed

    De la Cruz, Florentino B; Barlaz, Morton A

    2010-06-15

    The current methane generation model used by the U.S. EPA (Landfill Gas Emissions Model) treats municipal solid waste (MSW) as a homogeneous waste with one decay rate. However, component-specific decay rates are required to evaluate the effects of changes in waste composition on methane generation. Laboratory-scale rate constants, k(lab), for the major biodegradable MSW components were used to derive field-scale decay rates (k(field)) for each waste component using the assumption that the average of the field-scale decay rates for each waste component, weighted by its composition, is equal to the bulk MSW decay rate. For an assumed bulk MSW decay rate of 0.04 yr(-1), k(field) was estimated to be 0.298, 0.171, 0.015, 0.144, 0.033, 0.02, 0.122, and 0.029 yr(-1), for grass, leaves, branches, food waste, newsprint, corrugated containers, coated paper, and office paper, respectively. The effect of landfill waste diversion programs on methane production was explored to illustrate the use of component-specific decay rates. One hundred percent diversion of yard waste and food waste reduced the year 20 methane production rate by 45%. When a landfill gas collection schedule was introduced, collectable methane was most influenced by food waste diversion at years 10 and 20 and paper diversion at year 40.

  19. 23 CFR 751.7 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... This definition includes scrap metal processors, auto-wrecking yards, salvage yards, scrap yards, autorecycling yards, used auto parts yards and temporary storage of automobile bodies and parts awaiting...

  20. 23 CFR 751.7 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... This definition includes scrap metal processors, auto-wrecking yards, salvage yards, scrap yards, autorecycling yards, used auto parts yards and temporary storage of automobile bodies and parts awaiting...

  1. Democratic input into the nuclear waste disposal problem: The influence of geographical data on decision making examined through a Web-based GIS

    NASA Astrophysics Data System (ADS)

    Evans, Andrew J.; Kingston, Richard; Carver, Steve

    This paper elucidates the manner in which users of an online decision support system respond to spatially distributed data when assessing the solution to environmental risks, specifically, nuclear waste disposal. It presents tests for revealing whether users are responding to geographical data and whether they are influenced by their home location (Not in My Back Yard - style behavior). The tests specifically cope with problems associated with testing home-to-risk distances where both locations are constrained by the shape of the landmass available. In addition, we detail the users' wider feelings towards such a system, and reflect upon the possibilities such systems offer for participatory democracy initiatives.

  2. Installation Restoration Program Records Search for Air Force Plant 4, Texas.

    DTIC Science & Technology

    1984-08-01

    treatment, landfills, waste oil pits, chrome and die yard pits, disposal and spill sites. A total of 20 sites were ranked using the HARM (Hazard...Meteorology Iii-i B. Physical Geography 111-3 C. Hydrology 111-24 D. Ecology 111-44 1. Habitat 111-44 2. Threatened or Endangered Species 111-45 IV. FINDINGS A...ASSESSMENT RATING METHODOLOGY K. SITE RATING FORMS L. GLOSSARY OF TERMS M. LIST OF ACRONYMS, ABBREVIATIONS, AND SYMBOLS USED IN THE TEXT N. REFERENCES 0

  3. Electronic waste - an emerging threat to the environment of urban India.

    PubMed

    Needhidasan, Santhanam; Samuel, Melvin; Chidambaram, Ramalingam

    2014-01-20

    Electronic waste or e-waste is one of the emerging problems in developed and developing countries worldwide. It comprises of a multitude of components with valuable materials, some containing toxic substances, that can have an adverse impact on human health and the environment. Previous studies show that India has generated 0.4 million tons of e-waste in 2010 which may increase to 0.5 to 0.6 million tons by 2013-2014. Coupled with lack of appropriate infrastructural facilities and procedures for its disposal and recycling have posed significant importance for e-waste management in India. In general, e-waste is generated through recycling of e-waste and also from dumping of these wastes from other countries. More of these wastes are ending up in dumping yards and recycling centers, posing a new challenge to the environment and policy makers as well. In general electronic gadgets are meant to make our lives happier and simpler, but the toxicity it contains, their disposal and recycling becomes a health nightmare. Most of the users are unaware of the potential negative impact of rapidly increasing use of computers, monitors, and televisions. This review article provides a concise overview of India's current e-waste scenario, namely magnitude of the problem, environmental and health hazards, current disposal, recycling operations and mechanisms to improve the condition for better environment.

  4. Electronic waste – an emerging threat to the environment of urban India

    PubMed Central

    2014-01-01

    Electronic waste or e-waste is one of the emerging problems in developed and developing countries worldwide. It comprises of a multitude of components with valuable materials, some containing toxic substances, that can have an adverse impact on human health and the environment. Previous studies show that India has generated 0.4 million tons of e-waste in 2010 which may increase to 0.5 to 0.6 million tons by 2013–2014. Coupled with lack of appropriate infrastructural facilities and procedures for its disposal and recycling have posed significant importance for e-waste management in India. In general, e-waste is generated through recycling of e-waste and also from dumping of these wastes from other countries. More of these wastes are ending up in dumping yards and recycling centers, posing a new challenge to the environment and policy makers as well. In general electronic gadgets are meant to make our lives happier and simpler, but the toxicity it contains, their disposal and recycling becomes a health nightmare. Most of the users are unaware of the potential negative impact of rapidly increasing use of computers, monitors, and televisions. This review article provides a concise overview of India’s current e-waste scenario, namely magnitude of the problem, environmental and health hazards, current disposal, recycling operations and mechanisms to improve the condition for better environment. PMID:24444377

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Uisung; Han, Jeongwoo; Wang, Michael

    The amount of municipal solid waste (MSW) generated in the United States was estimated at 254 million wet tons in 2013, and around half of that generated waste was landfilled. There is a huge potential in recovering energy from that waste, since around 60% of landfilled material is biomass-derived waste that has high energy content. In addition, diverting waste for fuel production avoids huge fugitive emissions from landfills, especially uncontrolled CH 4 emissions, which are the third largest anthropogenic CH 4 source in the United States. Lifecycle analysis (LCA) is typically used to evaluate the environmental impact of alternative fuelmore » production pathways. LCA of transportation fuels is called well-to-wheels (WTW) and covers all stages of the fuel production pathways, from feedstock recovery (well) to vehicle operation (wheels). In this study, the Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation (GREET ®) model developed by Argonne National Laboratory is used to evaluate WTW greenhouse gas (GHG) emissions and fossil fuel consumption of waste-derived fuels. Two waste-to-energy (WTE) pathways have been evaluated – one for compressed natural gas (CNG) production using food waste via anaerobic digestion, and the other for ethanol production from yard trimmings via fermentation processes. Because the fuel production pathways displace current waste management practices (i.e., landfilling waste), we use a marginal approach that considers only the differences in emissions between the counterfactual case and the alternative fuel production case.« less

  6. Railroad classification yard technology : computer system methodology : case study : Potomac Yard

    DOT National Transportation Integrated Search

    1981-08-01

    This report documents the application of the railroad classification yard computer system methodology to Potomac Yard of the Richmond, Fredericksburg, and Potomac Railroad Company (RF&P). This case study entailed evaluation of the yard traffic capaci...

  7. Railroad classification yard design methodology study Elkhart Yard Rehabilitation : a case study

    DOT National Transportation Integrated Search

    1980-02-01

    This interim report documents the application of a railroad classification : yard design methodology to CONRAIL's Elkhart Yard Rehabilitation. This : case study effort represents Phase 2 of a larger effort to develop a yard : design methodology, and ...

  8. Railroad classification yard design methodology study : East Deerfield Yard, a case study

    DOT National Transportation Integrated Search

    1980-02-01

    This interim report documents the application of a railroad classification yard design methodology to Boston and Maine's East Deerfield Yard Rehabiliation. This case study effort represents Phase 2 of a larger effort to develop a yard design methodol...

  9. American black bears and bee yard depredation at Okefenokee Swamp, Georgia

    USGS Publications Warehouse

    Clark, J.D.; Dobey, S.; Masters, D.V.; Scheick, B.K.; Pelton, M.R.; Sunquist, M.E.

    2005-01-01

    We studied American black bears (Ursus americanus), on the northwest periphery of Okefenokee Swamp in southeast Georgia, to assess landowner attitudes toward bears, estimate the extent of damage to commercial honey bee operations by bears, and evaluate methods to reduce bear depredations to apiaries. We collected 8,351 black bear radiolocations and identified 51 bee yards on our study area. Twenty-seven of 43 home ranges contained ≥1 bee yard, averaging 11.3 and 5.1 bee yards/home range of males (n = 7) and females (n = 20), respectively. From 1996 to 1998, we documented 7 instances of bears raiding bee yards within our study area and 6 instances in adjacent areas. All but 1 of the 13 raided yards were enclosed by electric fencing. In the 12 cases of damage to electrically fenced yards, however, the fences were not active because of depleted batteries. Based on compositional analysis, bear use of areas 800–1,400 m from bee yards was disproportionately greater than use 0–800 m from bee yards. Bears disproportionately used bay (red bay: Persea borbonia, loblolly bay: Gordonia lasianthus, and southern magnolia: Magnolia virginia), gum (water tupelo: Nyssa aquatic and black gum: N. sylvatica), and cypress (Taxodium spp.) and loblolly bay habitats, however, compared with slash pine (Pinus elliottii) or pine–oak (Quercus spp.), where bee yards usually were placed. The distribution of bear radiolocations likely reflected the use of those swamp and riparian areas, rather than avoidance of bee yards. Distances to streams from damaged bee yards (x̄ = 1,750 m) were less than from undamaged yards (x̄ = 4,442 m), and damaged bee yards were closer to unimproved roads (x̄ = 134 m) than were undamaged bee yards (x̄ = 802 m). Our analysis suggests that bee yard placement away from bear travel routes (such as streams and unimproved roads) can reduce bear depredation problems. Our results strongly indicate that working electric fences are effective deterrents to bear damage to bee yards, even in areas frequented by bears. A survey of beekeepers indicated that apiarists often relied on more expensive, less effective, and sometimes illegal methods to protect their bee yards from bears. Beekeepers within bear range should be urged to consider electric fencing, which can almost eliminate bear damage to their yards.

  10. Summer cover crops and soil amendments to improve growth and nutrient uptake of okra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Q.R.; Li, Y.C.; Klassen, W.

    2006-04-15

    A pot experiment with summer cover crops and soil amendments was conducted in two consecutive years to elucidate the effects of these cover crops and soil amendments on 'Clemson Spineless 80' okra (Abelmoschus esculentus) yields and biomass production, and the uptake and distribution of soil nutrients and trace elements. The cover crops were sunn hemp (Crotalaria juncea), cowpea (Vigna unguiculata), velvetbean (Mucuna deeringiana), and sorghum sudan-grass (Sorghum bicolor x S. bicolor var. sudanense) with fallow as the control. The organic soil amendments were biosolids (sediment from wastewater plants), N-Viro Soil (a mixture of biosolids and coal ash), coal ash (amore » combustion by-product from power plants), co-compost (a mixture of 3 biosolids: 7 yard waste), and yard waste compost (mainly from leaves and branches of trees and shrubs, and grass clippings) with a soil-incorporated cover crop as the control. As a subsequent vegetable crop, okra was grown after the cover crops, alone or together with the organic soil amendments, had been incorporated. All of the cover crops, except sorghum sudangrass in 2002-03, significantly improved okra fruit yields and the total biomass production. Both cover crops and soil amendments can substantially improve nutrient uptake and distribution. The results suggest that cover crops and appropriate amounts of soil amendments can be used to improve soil fertility and okra yield without adverse environmental effects or risk of contamination of the fruit. Further field studies will be required to confirm these findings.« less

  11. Simulation of rail yard emissions transport to the near-source environment

    EPA Science Inventory

    Rail yards are critical nodes in the freight transportation network and locations of clustered emission sources. When people reside in close proximity to an active rail yard, the near-field effect of rail yard emissions is of concern. Field characterization of near-rail yard ai...

  12. University of Wisconsin Oshkosh Anaerobic Dry Digestion Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koker, John; Lizotte, Michael

    The University of Wisconsin Oshkosh Anaerobic Dry Digestion Facility is a demonstration project that supported the first commercial-scale use in the United States of high solids, static pile technology for anaerobic digestion of organic waste to generate biogas for use in generating electricity and heat. The research adds to the understanding of startup, operation and supply chain issues for anaerobic digester technology. Issues and performance were documented for equipment installation and modifications, feedstock availability and quality, weekly loading and unloading of digestion chambers, chemical composition of biogas produced, and energy production. This facility also demonstrated an urban industrial ecology approachmore » to siting such facilities near sewage treatment plants (to capture and use excess biogas generated by the plants) and organic yard waste collection sites (a source of feedstock).« less

  13. Superfund Record of Decision (EPA Region 1): Otis Air National Guard/Camp Edwards, MA. (First remedial action), May 1992. Interim report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-05-20

    The 22,000-acre Otis National Guard/Camp Edwards site is a former military vehicle maintenance facility on Cape Cod, Massachusetts, within the Massachusetts Military Reservation (MMR). The Area of Contamination Chemical Spill Area Number 4 (AOC CS-4) plume extends 11,000 feet and is located 1.1 miles from the southern boundary of MMR. Wastes and equipment handled at AOC CS-4 included oils, solvents, antifreeze, battery electrolytes, paint, and waste fuels. Additionally, the northern portion of AOC CS-4 was used as a storage yard for wastes generated by shops and laboratories operating at MMR. Liquid wastes were stored in containers or underground storage tanksmore » (USTs) in an unbermed area or deposited in USTs designated for motor gasoline. The ROD addresses OU2, the interim action for MMR AOC CS-4 ground water to prevent further down gradient migration of the contaminants. The primary contaminants of concern affecting the ground water are VOCs, including PCE and TCE.« less

  14. Hurricane Andrew: Impact on hazardous waste management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kastury, S.N.

    1993-03-01

    On August 24, 1992, Hurricane Andrew struck the eastern coast of South Florida with winds of 140 mph approximately and a storm surge of 15 ft. The Florida Department of Environmental Regulation finds that the Hurricane Andrew caused a widespread damage throughout Dade and Collier County as well as in Broward and Monroe County and has also greatly harmed the environment. The Department has issued an emergency final order No. 92-1476 on August 26, 1992 to address the environmental cleanup and prevent any further spills of contaminants within the emergency area. The order authorizes the local government officials to designatemore » certain locations in areas remote from habitation for the open burning in air certain incinerators of hurricane generated yard trash and construction and demolition debris. The Department staff has assisted the county and FEMA staff in establishing procedures for Hazardous Waste Management, Waste Segregation and disposal and emergency responses. Local governments have issued these burn permits to public agencies including FDOT and Corps of Engineering (COE). Several case studies will be discussed on the Hazardous Waste Management at this presentation.« less

  15. A Study of Strategic Lessons Learned in Vietnam. Volume 8. Results of the War

    DTIC Science & Technology

    1980-05-09

    and magnitude as to literally put uur system on trial.. They [Am’ericans] still want leaders who operate within the parameters of consent of the...governed. But they also desDerately want the leaders to know that the parameters of consenrt are changing drastically, radically, a barn-yard wide. Make no...mistake about it, this electorate no !Tnjer wants to be governed by leaders wed to the old parameters of consent, nor by those who would try to soothe

  16. Using liquid waste streams as the moisture source during the hydrothermal carbonization of municipal solid wastes.

    PubMed

    Li, Liang; Hale, McKenzie; Olsen, Petra; Berge, Nicole D

    2014-11-01

    Hydrothermal carbonization (HTC) is a thermal conversion process that can be an environmentally beneficial approach for the conversion of municipal solid wastes to value-added products. The influence of using activated sludge and landfill leachate as initial moisture sources during the carbonization of paper, food waste and yard waste over time at 250°C was evaluated. Results from batch experiments indicate that the use of activated sludge and landfill leachate are acceptable alternative supplemental liquid sources, ultimately imparting minimal impact on carbonization product characteristics and yields. Regression results indicate that the initial carbon content of the feedstock is more influential than any of the characteristics of the initial liquid source and is statistically significant when describing the relationship associated with all evaluated carbonization products. Initial liquid-phase characteristics are only statistically significant when describing the solids energy content and the mass of carbon in the gas-phase. The use of these alternative liquid sources has the potential to greatly increase the sustainability of the carbonization process. A life cycle assessment is required to quantify the benefits associated with using these alternative liquid sources. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. A system dynamics approach for hospital waste management in a city in a developing country: the case of Nablus, Palestine.

    PubMed

    Al-Khatib, Issam A; Eleyan, Derar; Garfield, Joy

    2016-09-01

    Hospitals and health centers provide a variety of healthcare services and normally generate hazardous waste as well as general waste. General waste has a similar nature to that of municipal solid waste and therefore could be disposed of in municipal landfills. However, hazardous waste poses risks to public health, unless it is properly managed. The hospital waste management system encompasses many factors, i.e., number of beds, number of employees, level of service, population, birth rate, fertility rate, and not in my back yard (NIMBY) syndrome. Therefore, this management system requires a comprehensive analysis to determine the role of each factor and its influence on the whole system. In this research, a hospital waste management simulation model is presented based on the system dynamics technique to determine the interaction among these factors in the system using a software package, ithink. This model is used to estimate waste segregation as this is important in the hospital waste management system to minimize risk to public health. Real data has been obtained from a case study of the city of Nablus, Palestine to validate the model. The model exhibits wastes generated from three types of hospitals (private, charitable, and government) by considering the number of both inpatients and outpatients depending on the population of the city under study. The model also offers the facility to compare the total waste generated among these different types of hospitals and anticipate and predict the future generated waste both infectious and non-infectious and the treatment cost incurred.

  18. Superfund Record of Decision (EPA Region 6): Petro-Chemical (Turtle Bayou), Liberty County, TX. (Second remedial action), September 1991. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-09-06

    The 500-acre Petro-Chemical (Turtle Bayou) site is in Liberty County, Texas. Current land use in the area is divided among cropland, pasture, range, forest, and small rural communities. Since 1971, numerous undocumented disposal activities occurred onsite involving primarily petrochemical wastes. The ROD for OU2 focuses on three areas of contamination at the site affecting soil and ground water contamination, known as the main waste area, the east disposal area, and the Bayou disposal area. The primary contaminants of concern affecting the soil and ground water are VOCs including benzene and xylenes; other organics including PAHs; and metals including lead. Themore » selected remedial action for the site includes treating 302,800 cubic yards of contaminated soil onsite using in-situ vapor extraction to remove VOCs, controlling vertical air infiltration using an engineered soil and synthetic liner cap; consolidating lead-contaminated soil in the Main Waste Area, followed by capping.« less

  19. Influence of aboveground tree biomass, home age, and yard maintenance on soil carbon levels in residential yards

    USDA-ARS?s Scientific Manuscript database

    In the past decade, research in urban soils has focused on the soil carbon (C) sequestration capacity in residential yards. We performed a case study to examine four potential drivers for soil C levels in residential yards. In 67 yards containing trees, we examined the relationship of soil C (kg m-2...

  20. Railroad Classification Yard Technology Manual: Volume II : Yard Computer Systems

    DOT National Transportation Integrated Search

    1981-08-01

    This volume (Volume II) of the Railroad Classification Yard Technology Manual documents the railroad classification yard computer systems methodology. The subjects covered are: functional description of process control and inventory computer systems,...

  1. Conservation and protection

    USGS Publications Warehouse

    Leopold, Luna Bergere

    1960-01-01

    When I was a child we had a burro I called Gacho. He was a typical burro, omnivorous in his eating habits and prone to streaks of extreme recalcitrance.Our yard wasn't very large, but it did produce enough grass and weeds to keep old Gacho in good fettle. His first preference was for the native grasses, and he chose to graze the lush patches rather than the shriveled plants on the areas of thin soil. Nevertheless, he was not particular and seemed to graze to some extent all over the yard. He often nibbled in the flower beds and I sometimes wondered whether he did this just for spite.After a time I arranged some crude fences and a tethering rope to keep him out of the most important flower beds.The yard was so small that we had a waste problem. To ignore the problem would hardly have been civilized, but, on the other hand, one couldn't follow him around all day with a shovel. So a workable compromise was adopted by keeping him penned up at night in a small enclosure, which, of course, could not be kept immaculate but was at least reasonably clean.We had the burro and we weren't getting rid of him. He was useful; we enjoyed riding him and hitching him up to our wagons. But he was a bother sometimes.Here was a simple case of resource use and resource development. The case is incomplete, but it demonstrates a principle.The resource, represented by the vegetation, was being utilized, or developed if you will, by a small juggernaut which was only partly controllable by my youthful skills. There was no need to urge utilization. That followed as a matter of course. The problem was that the one who utilized the resource, in this case the burro, was not very discerning of relative values. To Gacho the choice of which plant to eat and where to get rid of the waste was governed only by his own interests and convenience.Now, when a planning body convenes, one may bet that either the burro has Jain down in a flower bed or he has messed up the yard. By this time everybody is already in a lather.An appreciation of the existence of problems usually leads to a period of organizing the facts, assessing the current situation, and surveying the future possibilities. In the New England area such an assessment has recently been completed. Since that stage has been reached, it is logical to discuss the function of a planning unit as a prelude to the next phase. I should like to outline my own thoughts on this matter, but I do so without expecting to convince all others.

  2. Naturally Occurring Asbestos in Washington State: Swift Creek at the Intersection of Science, Law, and Risk Perception

    NASA Astrophysics Data System (ADS)

    Melious, J. O.

    2012-12-01

    In the northwestern corner of Washington state, a large landslide on Sumas Mountain deposits more than 100,000 cubic yards of soil containing asbestos fibers and heavy metals into Swift Creek every year. Engineers predict that asbestos-laden soils will slide into Swift Creek for at least the next 400 years. Swift Creek joins the Sumas River, which crosses the border into Canada, serving as an international delivery system for asbestos-laden soils. When the rivers flood, as happens regularly, they deliver asbestos into field, yards, and basements. The tools available to address the Swift Creek situation are at odds with the scope and nature of the problem. Asbestos regulation primarily addresses occupational settings, where exposures can be estimated. Hazardous waste regulation primarily addresses liability for abandoned waste products from human activities. Health and environmental issues relating to naturally occurring asbestos (NOA) are fundamentally different from either regulatory scheme. Liability is not a logical lever for a naturally occurring substance, the existence of which is nobody's fault, and exposures to NOA in the environment do not necessarily resemble occupational exposures. The gaps and flaws in the legal regime exacerbate the uncertainties created by uncertainties in the science. Once it is assumed that no level of exposure is safe, legal requirements adopted in very different contexts foreclose the options for addressing the Swift Creek problem. This presentation will outline the applicable laws and how they intersect with issues of risk perception, uncertainty and politics in efforts to address the Swift Creek NOA site.

  3. Linking Foraging Decisions to Residential Yard Bird Composition

    PubMed Central

    Lerman, Susannah B.; Warren, Paige S.; Gan, Hilary; Shochat, Eyal

    2012-01-01

    Urban bird communities have higher densities but lower diversity compared with wildlands. However, recent studies show that residential urban yards with native plantings have higher native bird diversity compared with yards with exotic vegetation. Here we tested whether landscape designs also affect bird foraging behavior. We estimated foraging decisions by measuring the giving-up densities (GUD; amount of food resources remaining when the final forager quits foraging on an artificial food patch, i.e seed trays) in residential yards in Phoenix, AZ, USA. We assessed how two yard designs (mesic: lush, exotic vegetation; xeric: drought-tolerant and native vegetation) differed in foraging costs. Further, we developed a statistical model to calculate GUDs for every species visiting the seed tray. Birds foraging in mesic yards depleted seed trays to a lower level (i.e. had lower GUDs) compared to birds foraging in xeric yards. After accounting for bird densities, the lower GUDs in mesic yards appeared largely driven by invasive and synanthropic species. Furthermore, behavioral responses of individual species were affected by yard design. Species visiting trays in both yard designs had lower GUDs in mesic yards. Differences in resource abundance (i.e., alternative resources more abundant and of higher quality in xeric yards) contributed to our results, while predation costs associated with foraging did not. By enhancing the GUD, a common method for assessing the costs associated with foraging, our statistical model provided insights into how individual species and bird densities influenced the GUD. These differences we found in foraging behavior were indicative of differences in habitat quality, and thus our study lends additional support for native landscapes to help reverse the loss of urban bird diversity. PMID:22927974

  4. Assessment and quantification of plastics waste generation in major 60 cities of India.

    PubMed

    Nalini, R; Srinivasulu, B; Shit, Subhas C; Nigam, Suneel Kumar; Akolkar, A B; Dwivedfi, R K

    2013-04-01

    Polymers or plastics materials registered rapid growth in 1970s, 1980s and 1990s at the rate of 2-2.5 times the GDP growth in India. The demand for plastic raw material got more than doubled from 3.3 Million Metric Ton to 6.8 Million Metric Tons in 2010 attributed mainly to rapid urbanization, spread of retail chains, plastics based packaging from grocery to food and vegetable products to cosmetics and consumer items. Plastics packages have its merits over many of conventional materials in the related sector but unless they are collected back effectively after their use to go into recycling process, they become an eyesore in the stream of Municipal Solid Waste (MSW) due to high visibility. As the synthetic and conventional plastics are non-biodegradable in nature, these remain in the dump yards/ landfills for several years, if not collected properly. Due to non- biodegradability, plastics waste remains in the environment for several years, if not collected and disposing plastics wastes at landfills are unsafe since toxic chemicals leach out into the soil and as they contaminate soil and underground water quality. The municipal solid waste also increasing day-by-day due to the inefficient source collection, segregation and transmission of plastics waste for recycling and reusing. In order to find out the realistic plastics waste generation, a study on assessment and quantification of plastics waste has been carried out by CPCB in collaboration with CIPET on selected 60 major cities of India.

  5. Composition variability of spent mushroom compost in Ireland.

    PubMed

    Jordan, S N; Mullen, G J; Murphy, M C

    2008-01-01

    Spent mushroom compost (SMC) has proven to be an attractive material for improving soil structure in tilled soils and increasing dry matter production in grassland soils, owing to its high organic matter content and availability of essential plant nutrients. Because of this, it is important to identify the variability in composition of SMC in order to evaluate its merit as a fertilizer/soil conditioner. For this reason, a study was carried out involving the analysis of SMC samples obtained from five mushroom growers using compost from each of the 13 mushroom composting yards currently operating in both Northern Ireland (5 yd) and the Republic of Ireland (8 yd). The selected parameters measured include dry matter, organic matter, total N, P and K, C/N ratio; plant-available P and K, pH, EC, total Ca, Mg, Na, Cu, Zn, Fe, Mn, Cd, Cr, Ni, Pb; and cellulose, hemicellulose and lignin constituents. Yield of mushroom data were also collected from the selected growers. There were significant differences (P<0.05) within two compost production yards for some parameters, therefore, for the most part, the uniformity of SMC within each yard is relatively consistent. However, significant differences (P<0.05) were evident when comparing SMC obtained from growers supplied with compost from Northern Ireland and the Republic of Ireland independently, particularly among total and available phosphorus and potassium values. The results obtained show that, while SMC has fertilizer merit, its variability of composition must be taken into account when assessing this value. The variability of composition is also of particular interest in the context of recent emphasis on plant nutrient management in agriculture.

  6. STOCK YARD LOOKING SOUTHEAST SHOWING OVERHEAD YARD CRANE RAIL, THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    STOCK YARD LOOKING SOUTHEAST SHOWING OVERHEAD YARD CRANE RAIL, THE MALLEABLE CUPOLAS AND EMISSION RECOVERY SYSTEM, OLD SHED ROOF THAT COVERED THE EARLIER MALLEABLE CUPOLA CHARGING CRANE, MALLEABLE FOUNDRY, AND POLLUTION CONTROL BAGHOUSE. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  7. SIMYAR: a cable-yarding simulation model.

    Treesearch

    R.J. McGaughey; R.H. Twito

    1987-01-01

    A skyline-logging simulation model designed to help planners evaluate potential yarding options and alternative harvest plans is presented. The model, called SIMYAR, uses information about the timber stand, yarding equipment, and unit geometry to estimate yarding co stand productivity for a particular operation. The costs of felling, bucking, loading, and hauling are...

  8. Reverse logistics system and recycling potential at a landfill: A case study from Kampala City.

    PubMed

    Kinobe, J R; Gebresenbet, G; Niwagaba, C B; Vinnerås, B

    2015-08-01

    The rapid growing population and high urbanisation rates in Sub-Saharan Africa has caused enormous pressure on collection services of the generated waste in the urban areas. This has put a burden on landfilling, which is the major waste disposal method. Waste reduction, re-use and recycling opportunities exist but are not fully utilized. The common items that are re-used and re-cycled are plastics, paper, aluminum, glass, steel, cardboard, and yard waste. This paper develops an overview of reverse logistics at Kiteezi landfill, the only officially recognised waste disposal facility for Kampala City. The paper analyses, in details the collection, re-processing, re-distribution and final markets of these products into a reversed supply chain network. Only 14% of the products at Kiteezi landfill are channeled into the reverse chain while 63% could be included in the distribution chain but are left out and disposed of while the remaining 23% is buried. This is because of the low processing power available, lack of market value, lack of knowledge and limited value addition activities to the products. This paper proposes possible strategies of efficient and effective reverse logistics development, applicable to Kampala City and other similar cities. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Superfund Record of Decision (EPA Region 5): Midco II, Gary, IN. (First remedial action), (amendment), April 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The 7-acre Midco II site is an abandoned chemical waste storage and disposal facility in Gary, Indiana. Land use in the surrounding area is predominantly industrial. The underlying aquifer, which is used primarily for non-drinking purposes, is highly susceptible to contamination from surface sources. From 1976 to 1978, the site was used for treatment, storage, and disposal of chemical and bulk liquid wastes. The ROD amends a 1989 ROD that addressed the remaining contaminated soil, pit wastes, and ground water by treatment of an estimated 35,000 cubic yards of soil wastes. The amended remedy reduces the estimated amount of soilmore » to be treated, as a result of new information on arsenic data and amended soil CALs, further defines the site cover requirements, and further defines the requirements for deep well injection of contaminated ground water. The primary contaminants of concern affecting the subsurface soil, sediment, and ground water are VOCs, including methylene chloride, benzene, toluene, TCE, and xylenes; other organics, including PCBs, phenols, and PAHs; and metals, including chromium, and lead. The amended remedial action for the ROD is included.« less

  10. Dustfall design of open coal yard in the power plant-a case study on the closed reconstruction project of coal storage yard in shengli power plant

    NASA Astrophysics Data System (ADS)

    Wang, Kunpeng; Ji, Weidong; Zhang, Feifei; Yu, Wei; Zheng, Runqing

    2018-02-01

    This thesis, based on the closed reconstruction project of the coal storage yard of Shengli Power Plant which is affiliated to Sinopec Shengli Petroleum Administration, first makes an analysis on the significance of current dustfall reconstruction of open coal yard, then summarizes the methods widely adopted in the dustfall of large-scale open coal storage yard of current thermal power plant as well as their advantages and disadvantages, and finally focuses on this project, aiming at providing some reference and assistance to the future closed reconstruction project of open coal storage yard in thermal power plant.

  11. Cleanups In My Community (CIMC) - Hazardous Waste Corrective Actions, National Layer

    EPA Pesticide Factsheets

    This data layer provides access to Hazardous Waste Corrective Action sites as part of the CIMC web service. Hazardous waste is waste that is dangerous or potentially harmful to our health or the environment. Hazardous wastes can be liquids, solids, gases, or sludges. They can be discarded commercial products, like cleaning fluids or pesticides, or the by-products of manufacturing processes. The RCRA Corrective Action Program, run by EPA and 43 authorized states and territories, works with facilities that have treated, stored, or disposed of hazardous wastes (TSDs) to protect public health and the environment by investigating and cleaning up hazardous releases to soil, ground water, surface water, and air at their facilities.RCRA Corrective Action sites in all 50 states and four U.S. territories cover 18 million acres of land.EPA estimates that more than 35 million people, roughly 12 percent of the U.S. population, live within one mile of a RCRA Corrective Action site (based on the 2000 U.S. Census).RCRA Corrective Action facilities include many current and former chemical manufacturing plants, oil refineries, lead smelters, wood preservers, steel mills, commercial landfills, and a variety of other types of entities. Due to poor practices prior to environmental regulations, Corrective Action facilities have left large stretches of river sediments laden with PCBs; deposited lead in residential yards and parks beyond site boundaries; polluted drinking water wells

  12. Near-source air quality in rail yard environments – an overview of recent EPA measurement and modeling findings

    EPA Science Inventory

    This presentation will providing a summary of field measurements conducted in areas surrounding two major rail yards as well as modeling simulations of rail yard emissions dispersion. The Cicero Rail Yard Study (CIRYS) was recently released to the public and includes mobile and ...

  13. 33 CFR 158.240 - Ship repair yards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Ship repair yards. 158.240... Facilities: Oily Mixtures § 158.240 Ship repair yards. The reception facility that services oceangoing ships using a ship repair yard must have a capacity for receiving— (a) An amount of ballast from bunker tanks...

  14. Computer assisted yarding cost analysis.

    Treesearch

    Ronald W. Mifflin

    1980-01-01

    Programs for a programable calculator and a desk-top computer are provided for quickly determining yarding cost and comparing the economics of alternative yarding systems. The programs emphasize the importance of the relationship between production rate and machine rate, which is the hourly cost of owning and operating yarding equipment. In addition to generating the...

  15. 33 CFR 158.240 - Ship repair yards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Ship repair yards. 158.240... Facilities: Oily Mixtures § 158.240 Ship repair yards. The reception facility that services oceangoing ships using a ship repair yard must have a capacity for receiving— (a) An amount of ballast from bunker tanks...

  16. 33 CFR 158.240 - Ship repair yards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Ship repair yards. 158.240... Facilities: Oily Mixtures § 158.240 Ship repair yards. The reception facility that services oceangoing ships using a ship repair yard must have a capacity for receiving— (a) An amount of ballast from bunker tanks...

  17. 33 CFR 158.240 - Ship repair yards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Ship repair yards. 158.240... Facilities: Oily Mixtures § 158.240 Ship repair yards. The reception facility that services oceangoing ships using a ship repair yard must have a capacity for receiving— (a) An amount of ballast from bunker tanks...

  18. Developments of solid materials for UF 6 sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Nicholas; Hebden, Andrew; Savina, Joseph

    2017-11-15

    This project demonstrated that a device using majority Commercial Off the Shelf (COTS) components could be used to collect uranium hexafluoride samples safely from gaseous or solid sources. The device was based on the successful Cristallini method developed by ABACC over the past 10 years. The system was designed to capture and store the UF 6 as an inert fluoride salt to ease transportation regulations. In addition, the method was considerably faster than traditional cryogenic methods, collected enough material to perform analyses without undue waste, and could be used either inside a facility or in the storage yard.

  19. 49 CFR 232.217 - Train brake tests conducted using yard air.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... reduction of brake pipe air pressure at the same, or slower, rate as an engineer's brake valve. (b) The yard... potential overcharge conditions to the train brake system are avoided, the yard air test device may be... section, when yard air is used the train air brake system must be charged and tested as prescribed by...

  20. 16 CFR § 1631.32 - Reasonable and representative tests and recordkeeping requirements-additional requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... records on the basis of linear yards or square yards as provided in § 1631.31 persons furnishing... of square yards. At least one test shall be performed upon commencement of production, importation, or other receipt of such small carpet or rug and every 25,000 units or square yards thereafter. (Sec...

  1. 16 CFR 1631.32 - Reasonable and representative tests and recordkeeping requirements-additional requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... records on the basis of linear yards or square yards as provided in § 1631.31 persons furnishing... of square yards. At least one test shall be performed upon commencement of production, importation, or other receipt of such small carpet or rug and every 25,000 units or square yards thereafter. (Sec...

  2. 16 CFR 1631.32 - Reasonable and representative tests and recordkeeping requirements-additional requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... records on the basis of linear yards or square yards as provided in § 1631.31 persons furnishing... of square yards. At least one test shall be performed upon commencement of production, importation, or other receipt of such small carpet or rug and every 25,000 units or square yards thereafter. (Sec...

  3. 16 CFR 1631.32 - Reasonable and representative tests and recordkeeping requirements-additional requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... records on the basis of linear yards or square yards as provided in § 1631.31 persons furnishing... of square yards. At least one test shall be performed upon commencement of production, importation, or other receipt of such small carpet or rug and every 25,000 units or square yards thereafter. (Sec...

  4. 16 CFR 1631.32 - Reasonable and representative tests and recordkeeping requirements-additional requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... records on the basis of linear yards or square yards as provided in § 1631.31 persons furnishing... of square yards. At least one test shall be performed upon commencement of production, importation, or other receipt of such small carpet or rug and every 25,000 units or square yards thereafter. (Sec...

  5. 32 CFR 707.3 - Yard arm signaling lights.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Yard arm signaling lights. 707.3 Section 707.3... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.3 Yard arm signaling lights. Naval vessels may display, as a means of visual signaling, white all round lights at the ends of the yard arms. These lights...

  6. 32 CFR 707.3 - Yard arm signaling lights.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 5 2014-07-01 2014-07-01 false Yard arm signaling lights. 707.3 Section 707.3... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.3 Yard arm signaling lights. Naval vessels may display, as a means of visual signaling, white all round lights at the ends of the yard arms. These lights...

  7. 32 CFR 707.3 - Yard arm signaling lights.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 5 2012-07-01 2012-07-01 false Yard arm signaling lights. 707.3 Section 707.3... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.3 Yard arm signaling lights. Naval vessels may display, as a means of visual signaling, white all round lights at the ends of the yard arms. These lights...

  8. 32 CFR 707.3 - Yard arm signaling lights.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 5 2011-07-01 2011-07-01 false Yard arm signaling lights. 707.3 Section 707.3... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.3 Yard arm signaling lights. Naval vessels may display, as a means of visual signaling, white all round lights at the ends of the yard arms. These lights...

  9. 32 CFR 707.3 - Yard arm signaling lights.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 5 2013-07-01 2013-07-01 false Yard arm signaling lights. 707.3 Section 707.3... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.3 Yard arm signaling lights. Naval vessels may display, as a means of visual signaling, white all round lights at the ends of the yard arms. These lights...

  10. Environmental Assessment: Reevaluation of the Le Claire Base Construction Storage Yard, Le Claire, Iowa

    DTIC Science & Technology

    1988-06-01

    RUYWAT~POF TU LZ CM AU1 CCRSTCTION STOIAGE YARD TS OF CONENT 3. Pupobe wA X 4 for Action EA- I 11. Project DescriptioO EA- 2 III. Alternatives EA- 4 IV...r W - - 3ENVIRONMENTAL ASSESSMENT REEVALUATION OF THE LE CLAIRE BASE CONSTRUCTION STORAGE YARD LE CLAIRE, IOWA I . PURPOSE AND NEED FOR...IDNR) boat ramp and the Corps storage yard will be relocated to the downstream (western) end of the new storage yard (see plate I ). The new road

  11. A survey of lead contamination in soil along Interstate 880, Alameda County, California.

    PubMed

    Teichman, J; Coltrin, D; Prouty, K; Bir, W A

    1993-09-01

    This study was undertaken to determine the levels of lead in soils taken from yards of homes in close proximity to a major freeway. Soils were collected from the yards of homes in communities adjacent to the freeway and within a 1-mile radius. Samples were analyzed using U.S. Environmental Protection Agency (EPA) methods and atomic absorption instrumentation. Ten percent of the samples were split and sent to a second laboratory for quality control. The possibility of lead-based paint contributing to the contamination was eliminated by sampling more than 20 feet from the homes. The soils closest to the highway showed lead levels exceeding California's and EPA's criteria for hazardous waste. A stratified sample of the depth of contamination in soils was also undertaken. Previously identified "hot spots" (soils with lead levels exceeding 500 ppm in the top 0.75 inch) were core sampled. Results indicated 90% of the subsurface samples contained lead exceeding the surface contaminations. This may be attributed to decades of urban lead-laden dust deposition. As the use of leaded gasolines have diminished in the past decade, the uppermost layers of soil/dust contained lower amounts of lead.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, A.S.C.

    The evaluation addresses the waste reduction/pollution prevention and economic issues involved in replacing chromated copper arsenate (CCA) with ammoniacal copper/quaternary ammonium (ACQ) as a way to preserve wood. The most obvious pollution prevention benefit gained by using ACQ is eliminating the use of arsenic and chromium, both of which generate hazardous wastes and a risk of contaminating the environment via chemical spills. Because most treatment plants are self-contained in that they reuse all wastewater produced within the plant and on the drip pads, no liquid waste problems were addressed for either the CCA or the ACQ treating process. The ACQmore » system generates more air pollution than does the CCA system, mainly as ammonia (NH3). For a plant with an annual production of 1 million cu ft (or about 20 million board feet), 90,000 lb of NH3 would be released per year from the ACQ treatment operations and the ACQ-treated wood. The treated wood, after being transferred from the drip pads to the outside storage yard, could become a major source of contamination.« less

  13. Cost and production analysis of the Bitterroot Miniyarder on an Appalachian hardwood site

    Treesearch

    John E. Baumgras; Penn A. Peters; Penn A. Peters

    1985-01-01

    An 18-horsepower skyline yarder was studied on a steep slope clearcut, yarding small hardwood trees uphill for fuelwood. Yarding cycle characteristics sampled include: total cycle time including delays, 5.20 minutes; yarding distance, 208 feet (350 feet maximum); turn volume, 11.6 cubic feet (24 cubic feet maximum); pieces per turn, 2.3. Cost analysis shows yarding...

  14. 33 CFR 110.46 - Newport Harbor, Newport, R.I.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... beginning. (b) Area No. 2. The waters east of Goat Island beginning at a point bearing 090°, 245 yards from Goat Island Shoal Light; thence 007°, 505 yards; thence 054°, 90 yards; thence 086°, 330 yards; thence... beginning. (c) Area No. 3. The waters north of Goat Island Causeway Bridge beginning at Newport Harbor Light...

  15. Emission of polybrominated diphenyl ethers (PBDEs) in use of electric/electronic equipment and recycling of e-waste in Korea.

    PubMed

    Park, Jong-Eun; Kang, Young-Yeul; Kim, Woo-Il; Jeon, Tae-Wan; Shin, Sun-Kyoung; Jeong, Mi-Jeong; Kim, Jong-Guk

    2014-02-01

    The emission rates of polybrominated diphenyl ethers (PBDEs) from electric/electronic products during their use and disposal were estimated. E-wastes, including televisions and refrigerators, gathered at recycling centers were also analyzed to estimate their emissions. The average concentrations of PBDEs in TV rear covers produced before and after the year 2000 were 145,027 mg/kg and 14,049 mg/kg, respectively. The PBDEs concentration in TV front covers was lower than the concentration in TV rear covers. The concentration in the components of the refrigerator samples ranged from ND to 445 mg/kg. We estimated the atmospheric emissions of PBDEs based on the concentrations. The annual emissions from TV rear covers produced before 2000 were calculated to be approximately 162.1 kg and after 2000, the annual emissions were 18.7 kg. Refrigerators showed the lowest annual emissions of PBDEs (0.7 kg). The atmospheric concentrations were also measured to calculate emissions generated during the recycling process. The highest concentration was 16.86 ng/m(3) emitted from the TV sets during the dismantling process. The concentrations of PBDEs generated in the plastic processing field ranged from 2.05 to 5.43 ng/m(3) depending on the products, and ambient air in open-air yards showed concentrations in the range of 0.32 to 5.55 ng/m(3). Emission factors for the recycling process were calculated using the observed concentrations. The estimated emissions according to the emission factors ranged from 0.3×10(-1) to 90.3 kg/year for open-air yards and from 0.1×10(-1) to 292.7 kg/year for the dismantling and crushing processes of TV set, depending on the production year. © 2013 Elsevier B.V. All rights reserved.

  16. 76 FR 20843 - Security Zone; Increase of Security Zones Under 33 CFR 165.1183 From 100 to 500 Yards; San...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-14

    .... SUMMARY: The Coast Guard will enforce a permanent increase in security zone size from 100 yards (91 meters) to 500 yards (457 meters) for tankers, cruise ships, and High Value Assets (HVAs) while underway on... Ports, Monterey Bay, and Humboldt Bay, CA, the security zone will decrease from 500 yards (457 meters...

  17. 77 FR 5463 - Safety Zones; Annually Recurring Marine Events in Coast Guard Southeastern New England Captain of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-03

    ...]10'83'' W (NAD 83). Safety Zone Dimension: Approximately 300 yard radius circle around the fireworks... Providence River, Providence, RI. Position: Within 500 yards of 41[deg]48'50'' N, 071[deg]23'43'' W (NAD 83... yards of 41[deg]42'37'' N, 071[deg]09'53'' W (NAD 83). Safety Zone Dimension: Approximately 200 yard...

  18. 49 CFR 232.217 - Train brake tests conducted using yard air.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... reduction of brake pipe air pressure at the same, or slower, rate as an engineer's brake valve. (b) The yard... (f). (2) At a minimum, yard air pressure shall be 60 psi at the end of the consist or block of cars... device. (3) If the air pressure of the yard test device is less than 80 psi, then a brake pipe leakage or...

  19. 49 CFR 232.217 - Train brake tests conducted using yard air.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... reduction of brake pipe air pressure at the same, or slower, rate as an engineer's brake valve. (b) The yard... (f). (2) At a minimum, yard air pressure shall be 60 psi at the end of the consist or block of cars... device. (3) If the air pressure of the yard test device is less than 80 psi, then a brake pipe leakage or...

  20. 49 CFR 232.217 - Train brake tests conducted using yard air.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... reduction of brake pipe air pressure at the same, or slower, rate as an engineer's brake valve. (b) The yard... (f). (2) At a minimum, yard air pressure shall be 60 psi at the end of the consist or block of cars... device. (3) If the air pressure of the yard test device is less than 80 psi, then a brake pipe leakage or...

  1. 49 CFR 232.217 - Train brake tests conducted using yard air.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... reduction of brake pipe air pressure at the same, or slower, rate as an engineer's brake valve. (b) The yard... (f). (2) At a minimum, yard air pressure shall be 60 psi at the end of the consist or block of cars... device. (3) If the air pressure of the yard test device is less than 80 psi, then a brake pipe leakage or...

  2. A Community-Designed Play-Yard Intervention to Prevent Microbial Ingestion: A Baby Water, Sanitation, and Hygiene Pilot Study in Rural Zambia.

    PubMed

    Reid, Brie; Seu, Rie; Orgle, Jennifer; Roy, Khrist; Pongolani, Catherine; Chileshe, Modesta; Fundira, Dadirai; Stoltzfus, Rebecca

    2018-06-04

    Malnourished children in low-income contexts usually suffer from environmental enteric dysfunction, which is damage to the intestines caused by chronic exposure to bacterial pathogens from feces hypothesized to contribute to stunting. Many intervention studies are piloting "Baby water, sanitation, and hygiene (WASH)" to help rural farming families reduce infant and young children's (IYC's) exposure to human and free-range livestock feces. One proposed Baby WASH intervention is a play-yard, which consists of a baby-proofed structure (i.e., playpen) that caregivers can place IYC into while doing chores around the household yard. This article describes the pilot development and assessment of a community-built Baby WASH play-yard and a plastic play-yard intervention with 21 caregivers of 6- to 24-month-old IYC in rural Zambia. A modified Trials of Improved Practices approach was used to conduct three visits in each household: an introductory visit during which play-yard use was explained, a second visit consisting of a semi-structured interview and a session of behavioral counseling, and a final visit which included a 2-hour observation of play-yard use. The second and final visits also included 24-hour recalls, and all three visits included spot observations of play-yard use. Reports from caregivers suggest that the community-built play-yard protected IYC from ingesting soil and livestock feces. Barriers to intervention use included caregivers' WASH beliefs and practices, community reactions, and play-yard maintenance. More work is needed to examine the role of women's time use in their home environment, community reactions to the intervention, and the biological efficacy to reduce microbial ingestion.

  3. East yard, north elevation of car department tool house (converted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    East yard, north elevation of car department tool house (converted from express car). - Chesapeake & Ohio Railroad, Thurmond Yards, East side New River, mouths of Arbuckle & Dunlop Circles, Thurmond, Fayette County, WV

  4. The Distribution and Movement of American Cockroaches in Urban Niches of New Orleans.

    PubMed

    Carlson, John C; Rabito, Felicia A; Werthmann, Derek; Fox, Mark

    2017-10-01

    American cockroaches are an important source of household allergens in tropical and semitropical climates. To determine which outdoor niches produce American cockroaches, traps were placed at 40 homes in New Orleans to collect nymphs. Nymphs were collected from the sewers, yards, and within the homes themselves. To compare sewers and yards as sources of cockroaches entering homes, adult cockroaches were collected, marked, and released into yards and sewers. No sewer-released cockroaches were collected in homes. Cockroaches released into yards were collected in the homes, suggesting that yards, rather than sewers, are a more important source niche. A field trial applying boric acid granules to the yard was performed in an effort to reduce entry of cockroaches. There was a significant reduction in the cockroach antigen collected in intervention homes compared with controls.

  5. Yarding cost for the Koller K300 cable yarder: results from field trials and simulations

    Treesearch

    Neil K. Huyler; Chris B. LeDoux

    1997-01-01

    This paper describes results from field studies and simulation that can be used to estimate the yarding cost for the Koller K300 cable yarder. Yarding costs can be estimated for clearcuts and light and heavy thinnings in eastern hardwoods. Yarding costs can be estimated with a handheld calculator, or the data can be incorporated into stump-to-mill desktop PC and...

  6. Optimising waste from electric and electronic equipment collection systems: a comparison of approaches in European countries.

    PubMed

    Friege, Henning; Oberdörfer, Michael; Günther, Marko

    2015-03-01

    The first European waste from electric and electronic equipment directive obliged the Member States to collect 4 kg of used devices per inhabitant and year. The target of the amended directive focuses on the ratio between the amount of waste from electric and electronic equipment collected and the mass of electric and electronic devices put on the market in the three foregoing years. The minimum collection target is 45% starting in 2016, being increased to 65% in 2019 or alternatively 85% of waste from electric and electronic equipment generated. Being aware of the new target, the question arises how Member States with 'best practice' organise their collection systems and how they enforce the parties in this playing field. Therefore the waste from electric and electronic equipment schemes of Sweden, Denmark, Switzerland, Germany and the Flemish region of Belgium were investigated focusing on the categories IT and telecommunications equipment, consumer equipment like audio systems and discharge lamps containing hazardous substances, e.g. mercury. The systems for waste from electric and electronic equipment collection in these countries vary considerably. Recycling yards turned out to be the backbone of waste from electric and electronic equipment collection in most countries studied. For discharge lamps, take-back by retailers seems to be more important. Sampling points like special containers in shopping centres, lidded waste bins and complementary return of used devices in all retail shops for electric equipment may serve as supplements. High transparency of collection and recycling efforts can encourage ambition among the concerned parties. Though the results from the study cannot be transferred in a simplistic manner, they serve as an indication for best practice methods for waste from electric and electronic equipment collection. © The Author(s) 2015.

  7. Macro scale models for freight railroad terminals.

    DOT National Transportation Integrated Search

    2016-03-02

    The project has developed a yard capacity model for macro-level analysis. The study considers the detailed sequence and scheduling in classification yards and their impacts on yard capacities simulate typical freight railroad terminals, and statistic...

  8. Advanced proceedings of the second classification yard technology workshop

    DOT National Transportation Integrated Search

    1981-05-01

    The purpose of this workshop was to present recent developments in yard related research along with discussing problem areas deserving further research. Also, railroad representatives will present reports on recently completed yard projects especiall...

  9. Chemometric evaluation of nitrate contamination in the groundwater of a hard rock area in Dharapuram, south India

    NASA Astrophysics Data System (ADS)

    Sajil Kumar, P. J.; Jegathambal, P.; James, E. J.

    2014-12-01

    This paper presents the results of investigations on groundwater nitrate contamination in the Dharapuram area of Tamil Nadu in south India as a primary step to initiate denitrification. Groundwater samples were collected from 26 selected locations during the pre-monsoon season in July 2010 and analysed for nitrate and other water quality parameters. Two important water types were identified, viz. Ca-Na-HCO3 and mixed Ca-Mg-Cl. It is found that the majority of samples possess high nitrate concentration; 57 % of samples exceeded the permissible limit of Indian (45 mg/L) and WHO (50 mg/L) drinking water standard. Spatial distribution map of NO3 suggested that major contamination was observed in the SW and NW parts of the study area. This result was in agreement with the corresponding land-use pattern in this study area. Denitrification process at greater depths was evident from the negative correlation between NO3 and well depth. The sources and controlling factors of high nitrate were investigated using cross plots of NO3 with other selected hydrochemical parameters. Positive correlation for NO3 was observed with EC, K, Cl and SO4. This analysis was capable of differentiating the various sources of nitrate in groundwater. The major sources of nitrate contamination are identified as areas of high fertilizer application, sewages and animal waste dumping yards. Regulation of these pollutant sources with appropriate and cost-effective denitrification process can restore the water quality in this area.

  10. Superfund record of decision (EPA Region 5): Muskego Sanitary Landfill, Muskego, WI. (First remedial action), June 1992. Interim report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-06-12

    The 56-acre Muskego Sanitary Landfill site was located in the City of Muskego, Waukesha County, Wisconsin. From the 1950's to 1981, municipal waste, waste oils, paint products, and other waste were disposed of at the site. The site was separated into three disposal areas: the Old Fill Area (38 acres); the Southeast Fill Area (16 acres); and the Non-Contiguous Fill Area (4.2 acres), composed of a drum trench, north and south refuse trenches, and an L-shaped fill area, all containing waste similar to the Old Fill Area. As a result of deteriorating water quality at onsite ground water monitoring wells,more » Waste Management of Wisconsin Inc. (WMWI) and the state conducted numerous investigations that revealed elevated levels of contaminants in the ground water. Two separate areas at the site were discovered to contain buried drums and contaminated soil. The first area was located east of the Non-Contiguous Fill Area. The second area, known as the drum trench, was discovered in a portion of the Non-Contiguous Fill Area and contained 989 drums and 2,500 cubic yards of contaminated soil. The interim ROD addressed the control and remediation of the contamination sources, including landfill waste, contaminated soils, leachate, and landfill gas. The primary contaminants of concern affecting the soil and ground water were VOCs, including benzene, toluene, and xylenes; and other organics, including chlorinated ethanes, ketones, PAHs, PCBs, pesticides, phenols, and phthalates.« less

  11. Informal processing of electronic waste at Agbogbloshie, Ghana: workers' knowledge about associated health hazards and alternative livelihoods.

    PubMed

    Yu, Emily A; Akormedi, Matthew; Asampong, Emmanuel; Meyer, Christian G; Fobil, Julius N

    2017-12-01

    This study was conducted to investigate the electronic waste workers' knowledge about the potential health hazards associated with their work as well as the livelihood alternatives that they would prefer if they were given the opportunity. A qualitative cross-sectional study was conducted to gather empirical information on e-waste workers' knowledge about the potential hazards associated with their work and the livelihood alternatives to e-waste recycling with a sample consisting of twenty all-male electronic waste workers at the Agbogbloshie scrap metal yard in Accra, Ghana. Electronic waste workers at Agbogbloshie were found to be exposed to a variety of injuries and illnesses. The workers' knowledge of the association between their health status and their work was generally poor. Apart from the physical injuries, they did not believe their work played any negative role in their health conditions. They preferred occupations such as farming or professional driving located in the northern region of Ghana to be closer to their families. The study concludes that the low knowledge level of the workers on the hazards that are associated with their work has implications for them accepting technologies to protect them and the natural environment from contamination. It is therefore imperative for any intervention to consider the current low level of knowledge and actively educate the workers to raise their awareness level, taking into account the provision of opportunities for workers to acquire applicable skills for future employment in other fields.

  12. Modeling Organic Contaminant Desorption from Municipal Solid Waste Components

    NASA Astrophysics Data System (ADS)

    Knappe, D. R.; Wu, B.; Barlaz, M. A.

    2002-12-01

    Approximately 25% of the sites on the National Priority List (NPL) of Superfund are municipal landfills that accepted hazardous waste. Unlined landfills typically result in groundwater contamination, and priority pollutants such as alkylbenzenes are often present. To select cost-effective risk management alternatives, better information on factors controlling the fate of hydrophobic organic contaminants (HOCs) in landfills is required. The objectives of this study were (1) to investigate the effects of HOC aging time, anaerobic sorbent decomposition, and leachate composition on HOC desorption rates, and (2) to simulate HOC desorption rates from polymers and biopolymer composites with suitable diffusion models. Experiments were conducted with individual components of municipal solid waste (MSW) including polyvinyl chloride (PVC), high-density polyethylene (HDPE), newsprint, office paper, and model food and yard waste (rabbit food). Each of the biopolymer composites (office paper, newsprint, rabbit food) was tested in both fresh and anaerobically decomposed form. To determine the effects of aging on alkylbenzene desorption rates, batch desorption tests were performed after sorbents were exposed to toluene for 30 and 250 days in flame-sealed ampules. Desorption tests showed that alkylbenzene desorption rates varied greatly among MSW components (PVC slowest, fresh rabbit food and newsprint fastest). Furthermore, desorption rates decreased as aging time increased. A single-parameter polymer diffusion model successfully described PVC and HDPE desorption data, but it failed to simulate desorption rate data for biopolymer composites. For biopolymer composites, a three-parameter biphasic polymer diffusion model was employed, which successfully simulated both the initial rapid and the subsequent slow desorption of toluene. Toluene desorption rates from MSW mixtures were predicted for typical MSW compositions in the years 1960 and 1997. For the older MSW mixture, which had a low plastics content, the model predicted that 50% of the initially sorbed toluene desorbed over a period of 5.8 days. In contrast, the model predicted that 50% of the initially sorbed toluene desorbed over a period of 4 years for the newer MSW mixture. These results suggest that toluene desorption rates from old MSW mixtures exceed methanogenic toluene degradation rates (toluene half-lives of about 30 to 100 days have been reported for methanogenic systems) and thus imply that biodegradation kinetics control the rate at which sorbed toluene is mineralized in old landfills. For newer MSW mixtures with a larger plastics content, toluene desorption rates are substantially slower; therefore, toluene desorption kinetics likely control the rate at which sorbed toluene can be mineralized in new landfills.

  13. An examination of railroad yard worker safety

    DOT National Transportation Integrated Search

    2001-07-01

    This report presents the methods, findings and recommendations from a multi-year research program that examined worker safety issues in railroad yards. The research program focused on human factor-related hazards and solutions to railroad yard worker...

  14. Railroad Classification Yard Technology : An Introductory Analysis of Functions and Operations

    DOT National Transportation Integrated Search

    1975-05-01

    A review of the basic operating characteristics and functions of railroad classification yards is presented. Introductory descriptions of terms, concepts, and problems of railroad operations involving classification yards are included in an attempt t...

  15. Assessing performance of feedlot operations using epidemiology.

    PubMed

    Corbin, Marilyn J; Griffin, Dee

    2006-03-01

    The progressive feedlot veterinarian must be well versed not only in individual production animal medicine, but also in population-based medicine. Feedlot health programs must be goal oriented, and evaluation of these goals is accomplished through diligent use of record systems and analytic evaluation of these record systems. Basic feedlot monitoring parameters include health and economic parameters in addition to the use of bench marking parameters between and among feed yards. When these parameters have significant changes, steps should be initiated to begin field investigations. Feedlot epidemiology uses several novel applications such as partial budgeting, risk assessment, and packing plant audits to provide scientifically sound and economically feasible solutions for the feeding industry.

  16. PES Holdings, LLC, et. al. Bankruptcy Renewable Fuel Standard Settlement

    EPA Pesticide Factsheets

    PES Holdings, LLC, North Yard Financing, LLC, North Yard GP, LLC, North Yard Logistics, L.P., PES Administrative Services, LLC, PES Logistics GP, LLC, PES Logistics Partners, L.P., Philadelphia Energy Solutions Refining and Marketing LLC (PESRM),

  17. East yard, looking southwest at car repairer's locker house (left), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    East yard, looking southwest at car repairer's locker house (left), switchment shanty (center), and material storage rack (right). - Chesapeake & Ohio Railroad, Thurmond Yards, East side New River, mouths of Arbuckle & Dunlop Circles, Thurmond, Fayette County, WV

  18. Gardening/yard work and depressive symptoms in African Americans

    PubMed Central

    Torres, Elisa R.; Sampselle, Carolyn M.; Ronis, David L.; Neighbors, Harold W.; Gretebeck, Kimberlee A.

    2015-01-01

    Background The purpose of this study was to examine the frequency of gardening/yard work in relation to depressive symptoms in African-Americans while controlling for biological and social factors. Methods A secondary analysis was performed on the National Survey of American Life (n=2,903) using logistic regression for complex samples. Gardening/yard work was measured by self-reported frequency. Depressive symptoms were measured with the Center for Epidemiologic Studies Depression scale. Results Biological and social factors, not gardening/yard work, were associated with depressive symptoms. Conclusions Biological and social factors may need to be addressed before the association between gardening/yard work and depressive symptoms can be determined. PMID:26992864

  19. Gardening/Yard Work and Depressive Symptoms in African Americans.

    PubMed

    Torres, Elisa R; Sampselle, Carolyn M; Ronis, David L; Neighbors, Harold W; Gretebeck, Kimberlee A

    2016-04-01

    The purpose of this study was to examine the frequency of gardening/yard work in relation to depressive symptoms in African-Americans while controlling for biological and social factors. A secondary analysis was performed on the National Survey of American Life (n=2,903) using logistic regression for complex samples. Gardening/Yard work was measured by self-reported frequency. Depressive symptoms were measured with the Center for Epidemiologic Studies Depression scale. Biological and social factors, not gardening/yard work, were associated with depressive symptoms. Biological and social factors may need to be addressed before the association between gardening/yard work and depressive symptoms can be determined. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. 33 CFR 110.173 - Port of Charleston, SC.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... located 1800 yards, 118° true from St. Michaels Church Spire and has a diameter of 500 yards. Vessels...°30′ true, 1375 yards from St. Michaels Church Spire and has a diameter of 1400 feet. The use of this...

  1. Antibiotics, Bacteria, and Antibiotic Resistance Genes: Aerial Transport from Cattle Feed Yards via Particulate Matter

    PubMed Central

    McEachran, Andrew D.; Blackwell, Brett R.; Hanson, J. Delton; Wooten, Kimberly J.; Mayer, Gregory D.; Cox, Stephen B.

    2015-01-01

    Background: Emergence and spread of antibiotic resistance has become a global health threat and is often linked with overuse and misuse of clinical and veterinary chemotherapeutic agents. Modern industrial-scale animal feeding operations rely extensively on veterinary pharmaceuticals, including antibiotics, to augment animal growth. Following excretion, antibiotics are transported through the environment via runoff, leaching, and land application of manure; however, airborne transport from feed yards has not been characterized. Objectives: The goal of this study was to determine the extent to which antibiotics, antibiotic resistance genes (ARG), and ruminant-associated microbes are aerially dispersed via particulate matter (PM) derived from large-scale beef cattle feed yards. Methods: PM was collected downwind and upwind of 10 beef cattle feed yards. After extraction from PM, five veterinary antibiotics were quantified via high-performance liquid chromatography with tandem mass spectrometry, ARG were quantified via targeted quantitative polymerase chain reaction, and microbial community diversity was analyzed via 16S rRNA amplification and sequencing. Results: Airborne PM derived from feed yards facilitated dispersal of several veterinary antibiotics, as well as microbial communities containing ARG. Concentrations of several antibiotics in airborne PM immediately downwind of feed yards ranged from 0.5 to 4.6 μg/g of PM. Microbial communities of PM collected downwind of feed yards were enriched with ruminant-associated taxa and were distinct when compared to upwind PM assemblages. Furthermore, genes encoding resistance to tetracycline antibiotics were significantly more abundant in PM collected downwind of feed yards as compared to upwind. Conclusions: Wind-dispersed PM from feed yards harbors antibiotics, bacteria, and ARGs. Citation: McEachran AD, Blackwell BR, Hanson JD, Wooten KJ, Mayer GD, Cox SB, Smith PN. 2015. Antibiotics, bacteria, and antibiotic resistance genes: aerial transport from cattle feed yards via particulate matter. Environ Health Perspect 123:337–343; http://dx.doi.org/10.1289/ehp.1408555 PMID:25633846

  2. Characterization of industrial waste from a natural gas distribution company and management strategies: a case study of the East Azerbaijan Gas Company (Iran).

    PubMed

    Taghipour, Hassan; Aslhashemi, Ahmad; Assadi, Mohammad; Khodaei, Firoz; Mardangahi, Baharak; Mosaferi, Mohammad; Roshani, Babak

    2012-10-01

    Although a fundamental prerequisite for the successful implementation of any waste management plan is the availability of sufficient and accurate data, there are few available studies regarding the characterization and management of gas distribution company waste (GDCW). This study aimed to characterize the industrial waste generated by the East Azerbaijan Gas Distribution Company (EAGDC) and to present environmental management strategies. The EAGDC serves 57 cities and 821 villages with a total population of more than 2.5 million as well as numerous industrial units. The methodology of this study was based on a checklist of data collected from each zone of the company, site visits (observation), and quantity and quality analysis according to the formal data available from different zones. The results indicate that more than 35 different kinds of industrial solid waste are generated in different industrial installations. The most important types of generated waste include empty barrels (including mercaptans, diesel fuel, deionized waters and oil), faulty gas meters and regulators, a variety of industrial oils, sleeves, filter elements and faulty pipes, valves and fittings. The results indicated that, currently, GDCW is generally handled and disposed of with domestic waste, deposited in companies' installation yards and stores or, sometimes, recycled through non-scientific approaches that can create health risks to the public and the environment, even though most of the GDCW was determined to be recyclable or reusable materials. This study concludes that gas distribution companies must pay more attention to source reduction, recycling and reusing of waste to preserve natural resources, landfill space and the environment.

  3. Noise level measurements of railroads : freight yards and wayside

    DOT National Transportation Integrated Search

    1974-05-01

    Noise from railroad operations were measured. Noise level data from freight yard operations were measured at the Argentine Freight Yard of the Santa Fe Railroad in Kansas City, Kansas and on a smaller scale in three facilities of the Boston and Maine...

  4. Composition and parameters of household bio-waste in four seasons.

    PubMed

    Hanc, Ales; Novak, Pavel; Dvorak, Milan; Habart, Jan; Svehla, Pavel

    2011-07-01

    Bio-waste makes up almost half portion of municipal solid waste. The characterization of household bio-waste is important in determining the most appropriate treatment method. The differences in composition and parameters of bio-waste derived from urban settlement (U-bio-waste) and family houses (F-bio-waste) during the four climate seasons are described in this paper. Twelve components and 20 parameters for bio-waste were evaluated. The composition of U-bio-waste was almost steady over those seasons, unlike F-bio-waste. U-bio-waste was comprised mainly (58.2%) of fruit and vegetable debris. F-bio-waste was primarily made up of seasonal garden components. The amount of variation among seasons in both type of bio-waste increased in sequence: basic parameters

  5. 78 FR 49511 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-14

    ... meeting on October 16, 2013, from 8:30 a.m. to 4:00 p.m. at the EPA Conference Facility at Potomac Yard, One Potomac Yard, Potomac Yard South, 2777 S. Crystal Dr., Arlington, VA 22202. Non-EPA attendees will...

  6. 77 FR 52272 - Safety Standard for Play Yards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-29

    ... Standard for Play Yards AGENCY: Consumer Product Safety Commission. ACTION: Notice of proposed rulemaking... to amend the play yard mandatory standard. This proposed rule would address the hazards associated... Improvement Act of 2008 (CPSIA), also known as the ``Danny Keysar Child Product Safety Notification Act...

  7. Gaseous emissions from outdoor concrete yards used by livestock

    NASA Astrophysics Data System (ADS)

    Misselbrook, T. H.; Webb, J.; Chadwick, D. R.; Ellis, S.; Pain, B. F.

    Measurements of ammonia (NH 3), nitrous oxide (N 2O) and methane (CH 4) were made from 11 outdoor concrete yards used by livestock. Measurements of NH 3 emission were made using the equilibrium concentration technique while closed chambers were used to measure N 2O and CH 4 emissions. Outdoor yards used by livestock proved to be an important source of NH 3 emission. Greatest emission rates were measured from dairy cow feeding yards, with a mean of 690 mg NH 3-N m -2 h -1. Smaller emission rates were measured from sheep handling areas, dairy cow collecting yards, beef feeding yards and a pig loading area, with respective mean emission rates of 440, 280, 220 and 140 mg NH 3-N m -2 h -1. Emission rates of N 2O and CH 4 were much smaller and for CH 4, in particular, emission rates were influenced greatly by the presence or absence of dung on the measurement area.

  8. Environmental Management Waste Management Facility Waste Lot Profile 155.5 for K-1015-A Laundry Pit, East Tennessee Technology Park Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bechtel Jacobs, Raymer J.E.

    2008-06-12

    In 1989, the Oak Ridge Reservation (ORR), which includes the East Tennessee Technology Park (ETTP), was placed on the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) National Priorities List. The Federal Facility Agreement (FFA) (DOE 1992), effective January 1, 1992, now governs environmental restoration activities conducted under CERCLA at the ORR. Following signing of the FFA, U.S. Department of Energy (DOE), U.S. Environmental Protection Agency (EPA), and the state of Tennessee signed the Oak Ridge Accelerated Cleanup Plan Agreement on June 18, 2003. The purpose of this agreement is to define a streamlined decision-making process to facilitatemore » the accelerated implementation of cleanup, to resolve ORR milestone issues, and to establish future actions necessary to complete the accelerated cleanup plan by the end of fiscal year 2008. While the FFA continues to serve as the overall regulatory framework for remediation, the Accelerated Cleanup Plan Agreement supplements existing requirements to streamline the decision-making process. The disposal of the K-1015 Laundry Pit waste will be executed in accordance with the 'Record of Decision for Soil, Buried Waste, and Subsurface Structure Actions in Zone, 2, East Tennessee Technology Park, Oak Ridge, Tennessee' (DOB/ORAH-2161&D2) and the 'Waste Handling Plan for the Consolidated Soil and Waste Sites with Zone 2, East Tennessee Technology Park, Oak Ridge, Tennessee' (DOE/OR/01-2328&D1). This waste lot consists of a total of approximately 50 cubic yards of waste that will be disposed at the Environmental Management Waste Management Facility (EMWMF) as non-containerized waste. This material will be sent to the EMWMF in dump trucks. This profile is for the K-1015-A Laundry Pit and includes debris (e.g., concrete, metal rebar, pipe), incidental soil, plastic and wood, and secondary waste (such as plastic sheeting, hay bales and other erosion control materials, wooden pallets, contaminated equipment, decontamination materials, etc.).« less

  9. 2. Long distance view from the SW of former Cotton ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Long distance view from the SW of former Cotton Yards (now used as a parking lot); Cotton Yard Gates at far right, Red Building and Produce Freight Warehouse in background. - Central of Georgia Railway, Cotton Yard Gates, West Broad Street, Savannah, Chatham County, GA

  10. Supertankers Turn Taps to Reveille

    ERIC Educational Resources Information Center

    Larkin, Timothy

    1974-01-01

    Seven years after the Brooklyn Navy Yard was closed, the Yard was reopened through the efforts of Seatrain Shipbuilding Corporation to build oil tankers. A training program for unemployed and unskilled minority group members in the area of the yard was established through JOBS, revitalizing an economically depressed area. (AG)

  11. Ammonia emissions from outdoor concrete yards used by livestock—quantification and mitigation

    NASA Astrophysics Data System (ADS)

    Misselbrook, T. H.; Webb, J.; Gilhespy, S. L.

    Outdoor concrete yards are commonly found on UK livestock farms, and, to a lesser extent, elsewhere in Europe, and represent a potentially significant source of ammonia (NH 3) emissions to the atmosphere. This study provided further measurements from a larger sample than previously made, to improve the robustness of the estimate of total NH 3 emission for inclusion in the UK NH 3 emission inventory. In addition, an assessment was made of a number of potential mitigation strategies. Measurements were made using the equilibrium concentration technique, employing small dynamic chambers and passive diffusion samplers, from 20 yards used by livestock on commercial farms. Mean emission rates (±standard error) were 0.31±0.07, 0.23±0.12, 0.19±0.05 and 0.18±0.09 g NH 3-N m -2 h -1 (0.70±0.21, 0.53±0.34, 0.76±0.22 and 0.18±0.14 g NH 3-N animal -1 h -1) for dairy cow-collecting yards, dairy cow-feeding yards, beef-feeding yards and sheep-feeding/handling areas, respectively, with mean respective livestock densities of 0.3, 0.5, 0.2 and 1.1 animals per m 2. There was a significant effect of season, with lower emission rates in the winter. There was a significant, albeit poor, positive linear relationship between emission rate and ambient air temperature ( r2=0.22) and between emission rate and total ammoniacal N content on the yard surface ( r2=0.14), but not with ambient wind speed. Pooling data from the present study with that from previous studies gave mean emission factors of 0.47±0.09, 0.98±0.39 and 0.13±0.09 g NH 3-N animal -1 h -1 for yards used by dairy cattle, beef cattle and sheep, respectively. Inclusion of these values, together with survey data on yard use, gave a total annual UK emission of approximately 25 kt NH 3 (95% confidence interval of 12-40 kt NH 3), representing almost 10% of total NH 3 emission from UK agriculture. In controlled studies, pressure washing and the use of a urease inhibitor in addition to yard scraping were found to be effective means of reducing emissions compared with yard scraping alone. Reduction of yard area per animal was also an effective strategy to reduce total emissions.

  12. Fate, transport, and interactions of heavy metals.

    PubMed

    Serrano, O R

    1995-02-01

    Mishandling of hazardous wastes, like their unauthorized disposal in abandoned dump yards or sites, in river beds, estuaries or in the sea, causes substantial damage to the environment and its resources and, given the persistence and toxicity of these pollutants, they can seriously damage human health and quality of life. The importance of controlling management, transport, and disposal of toxic and hazardous substances in the years to come will be a crucial issue in the design and implementation of public policies. This is especially true for residents of such areas as the border between the United States and Mexico, where historically hazardous wastes have been a public health and environmental problem. The aim of this Conference on the Fate, Transport, and Interactions of Metals, A Joint United States-Mexico Conference, co-sponsored by the National Institute of Environmental Health Sciences, Superfund Basic Research Program, the National University of Mexico, Program for the Environment and the Pan American Health Organization, and hosted by the University of Arizona Center for Toxicology, College of Pharmacy, is to begin a joint effort by the United States and Mexico to better understand the complex problems related to heavy metals as hazardous wastes.

  13. Fate, transport, and interactions of heavy metals.

    PubMed Central

    Serrano, O R

    1995-01-01

    Mishandling of hazardous wastes, like their unauthorized disposal in abandoned dump yards or sites, in river beds, estuaries or in the sea, causes substantial damage to the environment and its resources and, given the persistence and toxicity of these pollutants, they can seriously damage human health and quality of life. The importance of controlling management, transport, and disposal of toxic and hazardous substances in the years to come will be a crucial issue in the design and implementation of public policies. This is especially true for residents of such areas as the border between the United States and Mexico, where historically hazardous wastes have been a public health and environmental problem. The aim of this Conference on the Fate, Transport, and Interactions of Metals, A Joint United States-Mexico Conference, co-sponsored by the National Institute of Environmental Health Sciences, Superfund Basic Research Program, the National University of Mexico, Program for the Environment and the Pan American Health Organization, and hosted by the University of Arizona Center for Toxicology, College of Pharmacy, is to begin a joint effort by the United States and Mexico to better understand the complex problems related to heavy metals as hazardous wastes. PMID:7621804

  14. Atlanta Rail Yard Study: Evaluation of local-scale air pollution trends using stationary and mobile monitoring

    EPA Science Inventory

    Intermodal rail yards are important nodes in the freight transportation network, where freight is organized and moved from one mode of transport to another, critical equipment is serviced, and freight is routed to its next destination. Rail yard environments are also areas with ...

  15. 27. Historic drawing, Marine Railway. Detail of Emergency Brake, 1917. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. Historic drawing, Marine Railway. Detail of Emergency Brake, 1917. Photographic copy of original. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 13439, #551-16 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  16. 21. Historic drawing, Marine Railway. Equalizing Gear Layout, 1917. Photographic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Historic drawing, Marine Railway. Equalizing Gear Layout, 1917. Photographic copy of original. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 13439, #551-4 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  17. 19. Historic drawing, Marine Railway. Cradle and Track Plan, 1917. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Historic drawing, Marine Railway. Cradle and Track Plan, 1917. Photographic copy of original. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 13439, #551-1 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  18. 24. Historic drawing, Marine Railway. Wrought Iron Details, 1917. Photographic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Historic drawing, Marine Railway. Wrought Iron Details, 1917. Photographic copy of original. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 13439, #551-8A - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  19. 20. Historic drawing, Marine Railway. Design of Cradle, 1917. Photographic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Historic drawing, Marine Railway. Design of Cradle, 1917. Photographic copy of original. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 13439, #551-2 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  20. 23. Historic drawing, Marine Railway. Details of Hauling Machinery, 1917. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. Historic drawing, Marine Railway. Details of Hauling Machinery, 1917. Photographic copy of original. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 13439, #551-7 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  1. 25. Historic drawing, Marine Railway. Proposed Road Over Chains, 1917. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. Historic drawing, Marine Railway. Proposed Road Over Chains, 1917. Photographic copy of original. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 13439, #551-9 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  2. 22. Historic drawing, Marine Railway. Track Plan, 1917. Photographic copy ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. Historic drawing, Marine Railway. Track Plan, 1917. Photographic copy of original. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 13439, #551-5 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  3. Review of log sort yards

    Treesearch

    John Rusty Dramm; Gerry L. Jackson; Jenny Wong

    2002-01-01

    This report provides a general overview of current log sort yard operations in the United States, including an extensive literature review and information collected during on-site visits to several operations throughout the nation. Log sort yards provide many services in marketing wood and fiber by concentrating, merchandising, processing, sorting, and adding value to...

  4. Environmental Compliance Assessment System (ECAS) - Oregon Supplement

    DTIC Science & Technology

    1994-04-01

    m2 square meter yd yard m 3 cubic meter ys 2 square yard mg milligram yd3 cubic yard mi 1inc yr year lag microgram JAm micrometer 4lPa micropascals...Wilderness, Strawberry Mountain Wilder- ness, Diamond Peak Wilderness, Crater Lake National Park, Kalmiopsis Wilderness, Mountain Lake Wilderness, and

  5. Remedial investigation work plan for Bear Creek Valley Operable Unit 2 (Rust Spoil Area, SY-200 Yard, Spoil Area 1) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Environmental Restoration Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-05-01

    The enactment of the Resource Conservation and Recovery Act (RCRA) in 1976 and the Hazardous and Solid Waste Amendments (HSWA) to RCRA in 1984 created management requirements for hazardous waste facilities. The facilities within the Oak Ridge Reservation (ORR) were in the process of meeting the RCRA requirements when ORR was placed on the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) National Priorities List (NPL) on November 21, 1989. Under RCRA, the actions typically follow the RCRA Facility Assessment (RFA)/RCRA Facility Investigation (RFI)/Corrective Measures Study (CMS)/Corrective Measures implementation process. Under CERCLA the actions follow the PA/SI/Remedial Investigation (RI)/Feasibility Studymore » (FS)/Remedial Design/Remedial Action process. The development of this document will incorporate requirements under both RCRA and CERCLA into an RI work plan for the characterization of Bear Creek Valley (BCV) Operable Unit (OU) 2.« less

  6. Lessons Learned: Tribal Community Engagement, Remediation and Restoration of a Uranium Mine Tailings Site, Navajo Nation - 12484

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wadsworth, Donald K.; Hicks, Allison H.

    2012-07-01

    In May, 2011 New World Environmental Inc. was awarded a contract by the Navajo Nation Environmental Protection Agency to remediate an illegal radioactive waste disposal site located in the Navajo Nation. The initial scope included the excavation and shipment of an estimated 3,000 cubic yards of Uranium mine tailings and associated industrial waste. In this instance Stakeholders were supportive of the project, remediation and restoration, yet the movement of residual radioactive materials through tribal communities was a controversial issue. Other Stakeholder issues included site security, water sources for remediation activities, local residents' temporary re-location and care of livestock, right ofmore » way permissions and local workforce development. This presentation recaps the technical and non-technical issues encountered in the remediation and restoration the seven acre site and the outreach to surrounding communities. Cultural and equity issues resulting from historical problems associated with this and other sites in the immediate area and education and training. (authors)« less

  7. 17. General view, 'West End S.P. Inspection Building', view ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. General view, 'West End - S.P. Inspection Building', view to east, August 16, 1939. Bridge Yard Interlocking Tower and main line tracks at left, Oil House and storage yard at right. An Interurban Electric Railway car, with power supply pantograph raised, is visible at left of the building, another is just visible inside the building's left (north) bay, and still others are visible in the storage yard at right. - Interurban Electric Railway Bridge Yard Shop, Interstate 80 at Alameda County Postmile 2.0, Oakland, Alameda County, CA

  8. Electric utility pole yard training facility: Designing an effective learning environment

    NASA Astrophysics Data System (ADS)

    Topping, Robert P.

    The primary responsibility of electric utilities is to supply consistent, dependable, and affordable energy to private customers, businesses, and industries. As with many businesses, electric utilities are experiencing the effects of an aging workforce and expending considerable resources to train their current and replacement workers. Community colleges can partner with electric utilities to provide effective learning environments for these workers, and gain access to new sources of revenue and community support for the colleges. The purpose of this study was to describe the functions, features, and major design issues of an effective learning environment for training electric utility industry workers, the electric utility line-worker pole yard. Case studies of three "state of the art" line-worker pole yard training environments provide the basis for the study's findings and implications. The study was guided by the following research questions: (1) What is the function of a line-worker pole yard in supporting effective training? (2) What are the features of present day ("state of the art") line-worker pole yard learning environments? and (3) What are the major issues that need to be addressed in designing a line-worker pole yard learning environment for the future? The study participants included industry representatives, training coordinators, instructors, and students from the three selected "state of the art" line-worker pole yard sites. The overall findings from the study resulted in composites of the desired features of learning outcomes, learning process, and learning environment for a line-worker pole yard training program and major issues that are affecting the future design of these training programs. Composite findings of a pole-yard training environment included unique features associated with: (a) outdoor, (b) indoor, (c) underground, (d) classroom, (e) gathering places, and (f) work-based learning components. Composite findings with regard to major issues that need to be considered in future designs of pole-yard training environments included: (a) available unrestricted land for expansion, (b) resource commitment level, (c) workforce demographics, (d) aging industrial infrastructure, (e) electronic information and communication capability, (f) quality and quantity of available instructors, and (g) environmental and economic impact.

  9. Reverse logistics system and recycling potential at a landfill: A case study from Kampala City

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinobe, J.R., E-mail: joel.kinobe@slu.se; Department of Civil and Environmental Engineering, Makerere University College of Engineering, Design, Art and Technology; Gebresenbet, G.

    Highlights: • Quantifies the different waste streams delivered at the landfill. • Evaluates the amount of potential waste products that enters into the reverse cycle. • Drawing out the reverse logistics activities from Kampala City to Kiteezi landfill. • Identify the storage, collection and transportation mechanisms of products to the various destinations; and finally. • The study suggests efficient measures to improve reverse logistics system. - Abstract: The rapid growing population and high urbanisation rates in Sub-Saharan Africa has caused enormous pressure on collection services of the generated waste in the urban areas. This has put a burden on landfilling,more » which is the major waste disposal method. Waste reduction, re-use and recycling opportunities exist but are not fully utilized. The common items that are re-used and re-cycled are plastics, paper, aluminum, glass, steel, cardboard, and yard waste. This paper develops an overview of reverse logistics at Kiteezi landfill, the only officially recognised waste disposal facility for Kampala City. The paper analyses, in details the collection, re-processing, re-distribution and final markets of these products into a reversed supply chain network. Only 14% of the products at Kiteezi landfill are channeled into the reverse chain while 63% could be included in the distribution chain but are left out and disposed of while the remaining 23% is buried. This is because of the low processing power available, lack of market value, lack of knowledge and limited value addition activities to the products. This paper proposes possible strategies of efficient and effective reverse logistics development, applicable to Kampala City and other similar cities.« less

  10. The Educational Index: Linking Academic Instruction to Capital Planning

    ERIC Educational Resources Information Center

    Anding, Craig W.; Richards, David; Zoller, Susan C.

    2012-01-01

    The Bailey Yard is the largest rail classification yard in the world, stretching eight miles across the western prairie at North Platte, Nebraska. Trains leave Bailey Yard everyday--coal trains, grain trains, manifest trains--and each one represents a train prototype. Minneapolis Public School buildings are like a manifest train, where the…

  11. Is it time to revisit the log-sort yard?

    Treesearch

    John Dramm; Gerry Jackson

    2000-01-01

    Log-sort yards provide better utilization and marketing with improved value recovery of currently available timber resources in North America. Log-sort yards provide many services in marketing wood and fiber by concentrating, merchandising, manufacturing, sorting, and adding value to logs. Such operations supply forest products firms with desired raw materials, which...

  12. Historic drawing. Oxygen Distribution Piping System, 1944. Photographic copy of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Historic drawing. Oxygen Distribution Piping System, 1944. Photographic copy of original. Boston National Historical Park. Charlestown Navy Yard. BOSTS 13520, #631-1 - Charlestown Navy Yard, Oxygen Plant, Midway along northern boundary of Charlestown Navy Yard, on Little Mystic Channel, near junction of Eighteenth Street & Fourth Avenue, Boston, Suffolk County, MA

  13. 16. Historic view, Marine Railway construction. View to southeast, May ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. Historic view, Marine Railway construction. View to southeast, May 29, 1919. Photographic copy of photo. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 8962, USN #5049, 5/29/19 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  14. 15. Historic view, Marine Railway construction. View to southeast, May ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Historic view, Marine Railway construction. View to southeast, May 28, 1919. Photographic copy of photo. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 8962, USN #5046, 5/29/19 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  15. 11. Historic view, Marine Railway construction. View to southeast, July ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Historic view, Marine Railway construction. View to southeast, July 5, 1918. Photographic copy of photo. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 8962, USN #3988, 7/5/18 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  16. 12. Historic view, Marine Railway construction. View to southeast, September ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Historic view, Marine Railway construction. View to southeast, September 8, 1918. Photographic copy of photo. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 8962, USN #4229, 9/6/18 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  17. 13. Historic view, Marine Railway construction. View to southeast, March ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Historic view, Marine Railway construction. View to southeast, March 9, 1919. Photographic copy of photo. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 8962, USN #4801, 3/9/19 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  18. 28. Historic drawing, Marine Railway. Section showing bilge and keel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. Historic drawing, Marine Railway. Section showing bilge and keel blocks, 1919. Photographic copy of original. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 13439, #551-20 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  19. 14. Historic view, Marine Railway construction. View to southeast, May ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Historic view, Marine Railway construction. View to southeast, May 5, 1919. Photographic copy of photo. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 8962, USN #4930, 5/5/19 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  20. 49 CFR 218.35 - Yard limits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., or special instructions. (b) After August 1, 1977, each railroad must have in effect an operating..., within yard limits must move prepared to stop within onehalf the range of vision but not exceeding 20 m.p.h. unless the main track is known to be clear by block signal indications. (3) Within yard limits...

  1. 49 CFR 218.35 - Yard limits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., or special instructions. (b) After August 1, 1977, each railroad must have in effect an operating..., within yard limits must move prepared to stop within onehalf the range of vision but not exceeding 20 m.p.h. unless the main track is known to be clear by block signal indications. (3) Within yard limits...

  2. 49 CFR 218.35 - Yard limits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., or special instructions. (b) After August 1, 1977, each railroad must have in effect an operating..., within yard limits must move prepared to stop within onehalf the range of vision but not exceeding 20 m.p.h. unless the main track is known to be clear by block signal indications. (3) Within yard limits...

  3. 49 CFR 218.35 - Yard limits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., or special instructions. (b) After August 1, 1977, each railroad must have in effect an operating..., within yard limits must move prepared to stop within onehalf the range of vision but not exceeding 20 m.p.h. unless the main track is known to be clear by block signal indications. (3) Within yard limits...

  4. 49 CFR 218.35 - Yard limits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., or special instructions. (b) After August 1, 1977, each railroad must have in effect an operating..., within yard limits must move prepared to stop within onehalf the range of vision but not exceeding 20 m.p.h. unless the main track is known to be clear by block signal indications. (3) Within yard limits...

  5. [Analysis of accidents at work in building yards: correlation between risk and law defaults in yards of Palermo].

    PubMed

    Arcadipane, C; Verso, M G; Schillaci, S; Picciotto, D

    2007-01-01

    In the last years the building firm underwent real boom for investments and workers but not for safety measures. In the building sector there is a great accidents risks for falls from the top. The aim of present study is to analyze trend of accidents at work in building yards according to INAIL DATA and we will identify causes and risks then we will correlate these risks with frequent law defaults that we noticed in the province of Palermo. At the end we will value possible preventive measures to avoid this phenomenon. DATA INAIL of period 2001-2005 about building sector show us a reduction of denounced accidents at work but this phenomenon is changeable. Palermo is the first sicilian province for accidents at work although the number of denounced accidents (from 2001 to 2005) is decreasing while this number in Catania is increasing, CPT of Palermo gave us data (from 2004 to 2006) about inspections in building yards. Our study interests 609 yards and 1827 work stages. We noticed the most number of rests in civil yards.

  6. A comparison of landfill leachates based on waste composition.

    PubMed

    Moody, Chris M; Townsend, Timothy G

    2017-05-01

    Samples of leachate were collected from fourteen landfills in the state of Florida, United States that contained primarily putrescible waste (municipal solid waste, MSW, and yard waste), MSW incinerator (MSWI) ash, or a combination of both. Assessment of leachates included trace metals, anions, and nutrients in order to create a mass balance of total dissolved solids (TDS). As expected from previously literature, MSW leached a complex matrix of contaminants while MSWI ash leachate TDS was more than 98% metallic salts. The pH of the MSWI ash leachate samples was slightly acidic or neutral in character, which is contradictory to the results commonly reported in the literature. The cause of this is hypothesized to be a short-circuiting of rainfall in the landfill due to low hydraulic conductivities reported in ash landfills. The difference in pH likely contributed to the findings with respect to MSWI ash-characteristic trace metals in leachates such as aluminum. The authors have concluded that the research findings in this study are an indication of the differences between laboratory leachate quality studies and the conditions encountered in the field. In addition, a characterization of organic matter using qualitative and quantitative analyses determined that COD is not an accurate indicator of organic matter in leachates from landfills with a significant fraction of MSWI ash. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Adopted technologies and basis for selection at municipal solid waste landfill facilities constructed in recent years in Japan.

    PubMed

    Asakura, Hiroshi; Matsuto, Toshihiko; Inoue, Yuzo

    2010-08-01

    In Japan, as the construction of new landfill facilities has become extremely difficult and the number of sites procured for landfill construction has decreased due to the 'not in my back yard' (NIMBY) syndrome, it has been assumed that the adoption of new technologies has increased. As the performance of new technologies exceeds that of conventional technologies, it is also assumed that residents would prefer the use of these new technologies and therefore any construction plans should be devised to ensure their use to ensure residents' satisfaction. In the present study, the technologies adopted for municipal solid waste landfill facilities constructed in recent years (2000 to 2004) in Japan and the bases for their adoption were investigated by means of a questionnaire survey. One of the main bases for the adoption of new technologies was the request by residents for new technology for roofing, rather than the other for new technologies for barrier systems, leachate treatment, and monitoring. In addition, it is possible that the municipalities did not recognize the difference between conventional and new technologies as defined in this study. The roof-type landfill that isolates waste from the surrounding environment was one of the requirements for the construction of new landfill facilities identified in the present investigation, and in this regard waste isolation should be required in all circumstances.

  8. Biomass resources in California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tiangco, V.M.; Sethi, P.S.

    1993-12-31

    The biomass resources in California which have potential for energy conversion were assessed and characterized through the project funded by the California Energy Commission and the US Department of Energy`s Western Regional Biomass Energy Program (WRBEP). The results indicate that there is an abundance of biomass resources as yet untouched by the industry due to technical, economic, and environmental problems, and other barriers. These biomass resources include residues from field and seed crops, fruit and nut crops, vegetable crops, and nursery crops; food processing wastes; forest slash; energy crops; lumber mill waste; urban wood waste; urban yard waste; livestock manure;more » and chaparral. The estimated total potential of these biomass resource is approximately 47 million bone dry tons (BDT), which is equivalent to 780 billion MJ (740 trillion Btu). About 7 million BDT (132 billion MJ or 124 trillion Btu) of biomass residue was used for generating electricity by 66 direct combustion facilities with gross capacity of about 800 MW. This tonnage accounts for only about 15% of the total biomass resource potential identified in this study. The barriers interfering with the biomass utilization both in the on-site harvesting, collection, storage, handling, transportation, and conversion to energy are identified. The question whether these barriers present significant impact to biomass {open_quotes}availability{close_quotes} and {open_quotes}sustainability{close_quotes} remains to be answered.« less

  9. Atlanta Rail Yard Study: Evaluation of local-scale air pollution ...

    EPA Pesticide Factsheets

    Intermodal rail yards are important nodes in the freight transportation network, where freight is organized and moved from one mode of transport to another, critical equipment is serviced, and freight is routed to its next destination. Rail yard environments are also areas with multiple sources of air pollutant emissions (e.g., heavy-duty vehicles, locomotives, cranes), which may affect local air quality in residential areas nearby. In order to understand emissions and related air quality impacts, two field studies took place over the time span of 2010-2012 to measure air pollution trends in close proximity to the Inman and Tilford rail yard complex in Atlanta, GA. One field study involved long-term stationary monitoring of black carbon, fine particles, and carbon dioxide at two stations nearby the rail yard. In addition, a second field study performed intensive mobile air monitoring for a one month period in the summer of 2012 at a roadway network surrounding the rail yard complex and measured a comprehensive array of pollutants. Real-time mobile particulate measurements included particle counts, extinction coefficient, black carbon via light-absorption and particle incandescence, and particle composition derived by aerosol mass spectrometry. Gas-phase measurements included oxides of nitrogen, sulfur dioxide, carbon dioxide, and air toxics (e.g., benzene). Both sets of measurements determined detectable local influence from rail yard-related emissions.

  10. Risk factors for tick exposure in suburban settings in the Northeastern United States.

    PubMed

    Mead, P; Hook, S; Niesobecki, S; Ray, J; Meek, J; Delorey, M; Prue, C; Hinckley, A

    2018-02-01

    Prevention of tick-borne diseases requires an understanding of when and where exposure to ticks is most likely. We used an epidemiologic approach to define these parameters for residents of a Lyme-endemic region. Two persons in each of 500 Connecticut households were asked to complete a log each night for one week during June, 2013. Participants recorded their whereabouts in 15min increments (indoors, outdoors in their yard, outdoors on others' private property, or outdoors in public spaces) and noted each day whether they found a tick on themselves. Demographic and household information was also collected. Logs were completed for 934 participants in 471 households yielding 51,895 time-place observations. Median participant age was 49 years (range 2-91 years); 52% were female. Ninety-one participants (9.8%) reported finding a tick during the week, with slightly higher rates among females and minors. Household factors positively associated with finding a tick included having indoor/outdoor pets (odds ratio (OR)=1.7; 95% confidence interval (CI): 1.1-2.9), the presence of a bird feeder in the yard (OR=1.9; CI:1.2-3.2), and presence of an outdoor dining area (OR=2.2; CI:1.1-4.3). Individual factors associated with finding a tick on a given day were bathing or showering (OR=3.7; CI:1.3-10.3) and hours spent in one's own yard (OR=1.2, CI:1.1-1.3). Nineteen participants found ticks on multiple days, more than expected assuming independence (p<0.001). Participants who found ticks on multiple days did not spend more time outdoors but were significantly more likely to be male than those finding ticks on a single day (p<0.03). Our findings suggest that most tick exposures in the study area occurred on private property controlled by the respective homeowner. Interventions that target private yards are a logical focus for prevention efforts. Published by Elsevier GmbH.

  11. Atlanta Rail Yard Study (ARYS): Evaluation of local-scale air pollution trends and emissions quantification using stationary and mobile monitoring strategies

    EPA Science Inventory

    Intermodal rail yards are important nodes in the freight transportation network, where freight is organized and moved from one mode of transport to another, critical equipment is serviced, and freight is routed to its next destination. Rail yard environments are also areas with ...

  12. 49 CFR 1152.33 - Apportionment rules for the assignment of expenses to on-branch costs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... between diesel and other (electric). The costs for these accounts for yard locomotives shall be assigned to the branch separately for diesel and electric locomotives on the basis of the ratio of branch diesel and electric yard locomotive unit-hours to the total system diesel and electric yard locomotive...

  13. 49 CFR 1152.33 - Apportionment rules for the assignment of expenses to on-branch costs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... between diesel and other (electric). The costs for these accounts for yard locomotives shall be assigned to the branch separately for diesel and electric locomotives on the basis of the ratio of branch diesel and electric yard locomotive unit-hours to the total system diesel and electric yard locomotive...

  14. 49 CFR 1152.33 - Apportionment rules for the assignment of expenses to on-branch costs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... between diesel and other (electric). The costs for these accounts for yard locomotives shall be assigned to the branch separately for diesel and electric locomotives on the basis of the ratio of branch diesel and electric yard locomotive unit-hours to the total system diesel and electric yard locomotive...

  15. Harvesting costs and environmental impacts associated with skyline yarding shelterwood harvests and thinning in Appalachian hardwoods

    Treesearch

    J. E. Baumgras; C. B. LeDoux; J. R. Sherar

    1993-01-01

    To evaluate the potential for moderating the visual impact and soil disturbance associated with timber harvesting on steep-slope hardwood sites, thinning and shelterwood harvests were conducted with a skyline yarding system. Operations were monitored to document harvesting production, residual stand damage, soil disturbance, and visual quality. Yarding costs for...

  16. 49 CFR 1152.33 - Apportionment rules for the assignment of expenses to on-branch costs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... between diesel and other (electric). The costs for these accounts for yard locomotives shall be assigned to the branch separately for diesel and electric locomotives on the basis of the ratio of branch diesel and electric yard locomotive unit-hours to the total system diesel and electric yard locomotive...

  17. 49 CFR 1152.33 - Apportionment rules for the assignment of expenses to on-branch costs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... between diesel and other (electric). The costs for these accounts for yard locomotives shall be assigned to the branch separately for diesel and electric locomotives on the basis of the ratio of branch diesel and electric yard locomotive unit-hours to the total system diesel and electric yard locomotive...

  18. 17. Historic view, Test of Marine Railway, USCC Ossippee. View ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Historic view, Test of Marine Railway, USCC Ossippee. View to southeast, June 2, 1919. Photographic copy of photo. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 8962, USN #5054, 6/7/19 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  19. 33 CFR 110.55 - Connecticut River, Conn.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Vicinity of Mouse Island Bar below Portland. On the north side of the river shoreward of lines described as follows: (1) Beginning at a point bearing 02°, 175 yards, from Mouse Island 73 Light; thence 270°, 480... bearing 02°, 175 yards, from Mouse Island 73 Light; thence 70°, 400 yards; and thence 350°, approximately...

  20. 33 CFR 110.55 - Connecticut River, Conn.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Vicinity of Mouse Island Bar below Portland. On the north side of the river shoreward of lines described as follows: (1) Beginning at a point bearing 02°, 175 yards, from Mouse Island 73 Light; thence 270°, 480... bearing 02°, 175 yards, from Mouse Island 73 Light; thence 70°, 400 yards; and thence 350°, approximately...

  1. Global trade, local impacts: lessons from California on health impacts and environmental justice concerns for residents living near freight rail yards.

    PubMed

    Hricko, Andrea; Rowland, Glovioell; Eckel, Sandrah; Logan, Angelo; Taher, Maryam; Wilson, John

    2014-02-10

    Global trade has increased nearly 100-fold since 1950, according to the World Trade Organization. Today, major changes in trade are occurring with the advent of mega-ships that can transport thousands more containers than cargo ships now in use. Because global trade is expected to increase dramatically, the railroad industry-in the U.S. alone-has invested more than $5 billion a year over the past decade to expand rail yards and enhance rail routes to transport goods from ports to retail destinations. This article describes cancer risks for residents living in close proximity to rail yards with emissions of diesel particulate matter pollution from locomotives, trucks and yard equipment. The article examines the demographics (income, race/ethnicity) of populations living in the highest estimated cancer risk zones near 18 major rail yards in California, concluding that the majority are over-represented by either lower-income or minority residents (or both). The authors also describe a review of the news media and environmental impact reports to determine if rail yards are still being constructed or expanded in close proximity to homes and schools or in working class/working poor communities of color. The paper suggests policy efforts that might provide more public health protection and result in more "environmentally just" siting of rail yards. The authors conclude that diesel pollution from rail yards, which creates significant diesel cancer risks for those living near the facilities, is an often overlooked public health, health disparities and environmental justice issue in the U.S. The conclusions are relevant to other countries where international trade is increasing and large new intermodal rail facilities are being considered.

  2. Global Trade, Local Impacts: Lessons from California on Health Impacts and Environmental Justice Concerns for Residents Living near Freight Rail Yards

    PubMed Central

    Hricko, Andrea; Rowland, Glovioell; Eckel, Sandrah; Logan, Angelo; Taher, Maryam; Wilson, John

    2014-01-01

    Global trade has increased nearly 100-fold since 1950, according to the World Trade Organization. Today, major changes in trade are occurring with the advent of mega-ships that can transport thousands more containers than cargo ships now in use. Because global trade is expected to increase dramatically, the railroad industry—in the U.S. alone—has invested more than $5 billion a year over the past decade to expand rail yards and enhance rail routes to transport goods from ports to retail destinations. This article describes cancer risks for residents living in close proximity to rail yards with emissions of diesel particulate matter pollution from locomotives, trucks and yard equipment. The article examines the demographics (income, race/ethnicity) of populations living in the highest estimated cancer risk zones near 18 major rail yards in California, concluding that the majority are over-represented by either lower-income or minority residents (or both). The authors also describe a review of the news media and environmental impact reports to determine if rail yards are still being constructed or expanded in close proximity to homes and schools or in working class/working poor communities of color. The paper suggests policy efforts that might provide more public health protection and result in more “environmentally just” siting of rail yards. The authors conclude that diesel pollution from rail yards, which creates significant diesel cancer risks for those living near the facilities, is an often overlooked public health, health disparities and environmental justice issue in the U.S. The conclusions are relevant to other countries where international trade is increasing and large new intermodal rail facilities are being considered. PMID:24518649

  3. Refurbishment of uranium hexafluoride cylinder storage yards C-745-K, L, M, N, and P and construction of a new uranium hexafluoride cylinder storage yard (C-745-T) at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    The Paducah Gaseous Diffusion Plant (PGDP) is a uranium enrichment facility owned by the US Department of Energy (DOE). A residual of the uranium enrichment process is depleted uranium hexafluoride (UF6). Depleted UF6, a solid at ambient temperature, is stored in 32,200 steel cylinders that hold a maximum of 14 tons each. Storage conditions are suboptimal and have resulted in accelerated corrosion of cylinders, increasing the potential for a release of hazardous substances. Consequently, the DOE is proposing refurbishment of certain existing yards and construction of a new storage yard. This environmental assessment (EA) evaluates the impacts of the proposedmore » action and no action and considers alternate sites for the proposed new storage yard. The proposed action includes (1) renovating five existing cylinder yards; (2) constructing a new UF6 storage yard; handling and onsite transport of cylinders among existing yards to accommodate construction; and (4) after refurbishment and construction, restacking of cylinders to meet spacing and inspection requirements. Based on the results of the analysis reported in the EA, DOE has determined that the proposed action is not a major Federal action that would significantly affect the quality of the human environment within the context of the National Environmental Policy Act of 1969. Therefore, DOE is issuing a Finding of No Significant Impact. Additionally, it is reported in this EA that the loss of less than one acre of wetlands at the proposed project site would not be a significant adverse impact.« less

  4. Characterization and remediation of a mixed waste-contaminated site at Kirtland Air Force Base, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, J.W.; Thacker, M.S.; DeWitt, C.B.

    In the area of environmental restoration, one of the most challenging problems is the task of remediating mixed waste-contaminated sites. This paper discusses a successful Interim Corrective Measure (ICM) performed at a mixed waste-contaminated site on Kirtland Air Force Base (AFB) in Albuquerque, New Mexico. The site, known as RW-68, Cratering Area and Radium Dump/Slag Piles, was used during the late 1940s and early 1950s for the destruction and incineration of captured World War II aircraft. It contained 19 slag piles totaling approximately 150 tons of slag, ash, refractory brick, and metal debris. The piles were contaminated with radium-226 andmore » RCRA-characteristic levels of heavy metals. Therefore, the piles were considered mixed waste. To eliminate the threat to human health and the environment, an ICM of removal, segregation, stabilization, and disposal was conducted from October through December 1996. Approximately 120 cubic yards (cu yds) of mixed waste, 188 cu yds of low-level radioactive-contaminated soil, 1 cu yd of low-level radioactive-contaminated debris, 5 cu yds of RCRA-characteristic hazardous waste, and 45 tons of nonhazardous debris were stabilized and disposed of during the ICM. To render the RCRA metals and radionuclides insoluble, stabilization was performed on the mixed and RCRA-characteristic waste streams. All stabilized material was subjected to TCLP analysis to verify it no longer exhibited RCRA-characteristic properties. Radiological and geophysical surveys were conducted concurrently with site remediation activities. These surveys provided real-time documentation of site conditions during each phase of the ICM and confirmed successful cleanup of the site. The three radioactive waste streams, stabilized mixed waste, low-level radioactive-contaminated soil, and low-level radioactive-contaminated debris, were disposed of at the Envirocare low-level radioactive disposal facility.« less

  5. Experiences in the field of radioactive materials seizures in the Czech Republic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Svoboda, Karel; Podlaha, Josef; Sir, David

    2007-07-01

    In recent years, the amount of radioactive materials seizures (captured radioactive materials) has been rising. It was above all due to newly installed detection facilities that were able to check metallic scrap during its collection in scrap yards or on the entrance to iron-mills, checking municipal waste upon entrance to municipal disposal sites, even incineration plants, or through checking vehicles going through the borders of the Czech Republic. Most cases bore a relationship to secondary raw materials or they were connected to the application of machines and installations made from contaminated metallic materials. However, in accordance to our experience, themore » number of cases of seizures of materials and devices containing radioactive sources used in the public domain was lower, but not negligible, in the municipal storage yards or incineration plants. Atomic Act No. 18/1997 Coll. will apply to everybody who provides activities leading to exposure, mandatory assurance as high radiation safety as risk of the endangering of life, personal health and environment is as low as reasonably achievable in according to social and economic aspects. Hence, attention on the examination of all cases of the radioactive material seizure based on detection facilities alarm or reasonably grounds suspicion arising from the other information is important. Therefore, a service carried out by group of workers who ensure assessment of captured radioactive materials and eventual retrieval of radioactive sources from the municipal waste has come into existence in the Nuclear Research Institute Rez plc. This service has covered also transport, storage, processing and disposal of found radioactive sources. This service has arisen especially for municipal disposal sites, but later on even other companies took advantage of this service like incineration plants, the State Office for Nuclear Safety, etc. Our experience in the field of ensuring assessment of captured radioactive materials and eventual retrieval of radioactive sources will be presented in the paper. (authors)« less

  6. Yarding-method and slash-treatment effects on compaction, humus, and variation in plantation soils.

    Treesearch

    Don Minore; Howard G. Weatherly

    1988-01-01

    Soil penetration-resistance and soil-humus frequency were measured on 86 progeny-test plantations in southwestern Oregon to determine the effects of yarding method and slash treatment on soil compaction and humus, and a disturbance index was calculated for each plantation. Compaction and humus loss were more severe on tractor-yarded, machine-piled plantations than on...

  7. 18. Historic view, Test of Marine Railway, USS Grebe and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Historic view, Test of Marine Railway, USS Grebe and USS Acushnet. View to soutwest, June 10, 1919. Photographic copy of photo. Boston National Historical Park Archives, Charlestown Navy Yard. BOSTS 8962, USN #5080, 6/10/19 - Charlestown Navy Yard, Marine Railway, Between Piers 2 & 3, on Charlestown Waterfront at west end of Navy Yard, Boston, Suffolk County, MA

  8. Soil compaction after yarding of small-diameter Douglas-fir with a small tractor in southwest Oregon.

    Treesearch

    Michael P. Amaranthus; David E. Steinfeld

    1997-01-01

    This study evaluated the effect on soil bulk density of yarding small-diameter Douglas-fir (Pseudosuga menziesii var. glauca (Beissn.) Franco) with a small tractor. Levels of compaction were measured before yarding and after one trip, three trips, and six trips by the tractor. Bulk densities in the surface (10 cm) and...

  9. 5. Historic American Buildings Survey 'Plan of Navy Yard at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Historic American Buildings Survey 'Plan of Navy Yard at Washington Showing the Position and Dimensions of the Ground Plans of all Buildings as They Were 1st January 1858.' Photocopy of original drawing on file at Naval Station Public Works Department, Washington, D.C. - Navy Yard, Main Gate, Eighth & M Streets Southeast, Washington, District of Columbia, DC

  10. 67. September 1913 "No. 103. Oil being applied and raked ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    67. September 1913 "No. 103. Oil being applied and raked in, oil treated earth surface, experimental section. The frame in foreground was 1 x 5 yards, each square yard being indicated thereon, by which it was possible to determine the amount of oil placed in each square yard." - Crater Lake National Park Roads, Klamath Falls, Klamath County, OR

  11. Production rates and costs of cable yarding wood residue from clearcut units

    Treesearch

    Chris B. LeDoux

    1984-01-01

    Wood residue is a little used source of fiber, chips, and fuel because harvest costs are largely unknown. This study calculates incremental production rates and costs for yarding and loading logging residue in clearcut old-growth Douglas-fir/western hemlock forests. Harvest operations were observed for two timber sales in western Oregon. Three different cable yarding...

  12. Natural phenomena evaluations of the K-25 site UF{sub 6} cylinder storage yards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fricke, K.E.

    1996-09-15

    The K-25 Site UF{sub 6} cylinder storage yards are used for the temporary storage of UF{sub 6} normal assay cylinders and long-term storage of other UF{sub 6} cylinders. The K-25 Site UF{sub 6} cylinder storage yards consist of six on-site areas: K-1066-B, K-1066-E, K-1066-F, K-1066-J, K-1066-K and K-1066-L. There are no permanent structures erected on the cylinder yards, except for five portable buildings. The operating contractor for the K-25 Site is preparing a Safety Analysis Report (SAR) to examine the safety related aspects of the K-25 Site UF{sub 6} cylinder storage yards. The SAR preparation encompasses many tasks terminating inmore » consequence analysis for the release of gaseous and liquid UF{sub 6}, one of which is the evaluation of natural phenomena threats, such as earthquakes, floods, and winds. In support of the SAR, the six active cylinder storage yards were evaluated for vulnerabilities to natural phenomena, earthquakes, high winds and tornados, tornado-generated missiles, floods (local and regional), and lightning. This report summarizes those studies. 30 refs.« less

  13. Recording and Analysis of the Rec Yard at Alcatraz Island

    NASA Astrophysics Data System (ADS)

    Warden, R.; Toz, T. K.; Everett, M.; DeSmet, T.; Billingsley, A.; Hagin, J.

    2013-07-01

    In the summer of 2012 students and professors from the Concrete Industry Management (CIM ) program at California State University Chico, along with their partners at National Park Service, invited Texas A&M students and professors to join forces and perform a condition assessment of the Recreation Yard at Alcatraz Island in San Francisco Bay. The Recreation Yard is a heavily visited area by tourists who are drawn to the island because of its history as a maximum security prison in the 20th c. Because of its history, first as a military fort in the 19thc., later as a military prison, and finally as a federal prison, many difficult historical and preservation related questions exist. This team was formed to begin research on the historical and preservation questions with respect to the Recreation Yard. This paper and presentation will focus on the integration of documentation technologies employed to aid the research necessary for answering preservation and historical questions regarding the recreations yard. Since that yard was constructed on top of the historic 19th c masonry fort it was requested that we also seek the location of tunnels below the Recreation Yard and their relationship with the walls. Teams were formed to perform Non-destructive testing of concrete walls to determine the size and location of rebar, Ground Penetrating Radar for determining the location of the masonry tunnels and photogrammetry and laser scanning to provide both overall and detailed dimensional information of the current state of material decay.

  14. 33 CFR 110.157 - Delaware Bay and River.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...′59″, longitude 75°23′07″ ) bearing 228 from Ship John Shoal Light, 167 yards southwest of the...: Beginning at a point bearing 105° from the northernmost point of Reedy Island, 167 yards easterly of the... Range at latitude 39°31′43″, thence to a point bearing 168°30′, 3,150 yards, from Chesapeake and...

  15. 33 CFR 110.157 - Delaware Bay and River.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...′59″, longitude 75°23′07″) bearing 228 from Ship John Shoal Light, 167 yards southwest of the...: Beginning at a point bearing 105° from the northernmost point of Reedy Island, 167 yards easterly of the... Range at latitude 39°31′43″, thence to a point bearing 168°30′, 3,150 yards, from Chesapeake and...

  16. 33 CFR 110.157 - Delaware Bay and River.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...′59″, longitude 75°23′07″ ) bearing 228 from Ship John Shoal Light, 167 yards southwest of the...: Beginning at a point bearing 105° from the northernmost point of Reedy Island, 167 yards easterly of the... Range at latitude 39°31′43″, thence to a point bearing 168°30′, 3,150 yards, from Chesapeake and...

  17. 33 CFR 110.157 - Delaware Bay and River.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...′59″, longitude 75°23′07″) bearing 228 from Ship John Shoal Light, 167 yards southwest of the...: Beginning at a point bearing 105° from the northernmost point of Reedy Island, 167 yards easterly of the... Range at latitude 39°31′43″, thence to a point bearing 168°30′, 3,150 yards, from Chesapeake and...

  18. 33 CFR 110.157 - Delaware Bay and River.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...′59″, longitude 75°23′07″) bearing 228 from Ship John Shoal Light, 167 yards southwest of the...: Beginning at a point bearing 105° from the northernmost point of Reedy Island, 167 yards easterly of the... Range at latitude 39°31′43″, thence to a point bearing 168°30′, 3,150 yards, from Chesapeake and...

  19. Bucking logs to cable yarder capacity can decrease yarding costs and minimize wood wastage

    Treesearch

    Chris B. LeDoux

    1986-01-01

    Data from select time and motions studies and a forest model plot, used in a simulation model, show that logging managers planning felling, bucking, and limbing for a cable yarding operation must consider the effect of alternate bucking rules on wood wastage, yarding production rates and cost, the number of choker to fly and total logging costs. Results emphasize then...

  20. 77 FR 30188 - Safety Zones; Annually Recurring Marine Events in Coast Guard Southeastern New England Captain of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-22

    ...'83'' W (NAD 83). Safety Zone Dimension: Approximately 300 yard radius circle around the fireworks... Providence River, Providence, RI. Position: Within 500 yards of 41[deg]48'50'' N, 071[deg]23'43'' W (NAD 83... 500 yards of 41[deg]42'37'' N, 071[deg]09'53'' W (NAD 83). Safety Zone Dimension: Approximately 200...

  1. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  2. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  3. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  4. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  5. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  6. Estimating methane emissions from landfills based on rainfall, ambient temperature, and waste composition: The CLEEN model.

    PubMed

    Karanjekar, Richa V; Bhatt, Arpita; Altouqui, Said; Jangikhatoonabad, Neda; Durai, Vennila; Sattler, Melanie L; Hossain, M D Sahadat; Chen, Victoria

    2015-12-01

    Accurately estimating landfill methane emissions is important for quantifying a landfill's greenhouse gas emissions and power generation potential. Current models, including LandGEM and IPCC, often greatly simplify treatment of factors like rainfall and ambient temperature, which can substantially impact gas production. The newly developed Capturing Landfill Emissions for Energy Needs (CLEEN) model aims to improve landfill methane generation estimates, but still require inputs that are fairly easy to obtain: waste composition, annual rainfall, and ambient temperature. To develop the model, methane generation was measured from 27 laboratory scale landfill reactors, with varying waste compositions (ranging from 0% to 100%); average rainfall rates of 2, 6, and 12 mm/day; and temperatures of 20, 30, and 37°C, according to a statistical experimental design. Refuse components considered were the major biodegradable wastes, food, paper, yard/wood, and textile, as well as inert inorganic waste. Based on the data collected, a multiple linear regression equation (R(2)=0.75) was developed to predict first-order methane generation rate constant values k as functions of waste composition, annual rainfall, and temperature. Because, laboratory methane generation rates exceed field rates, a second scale-up regression equation for k was developed using actual gas-recovery data from 11 landfills in high-income countries with conventional operation. The Capturing Landfill Emissions for Energy Needs (CLEEN) model was developed by incorporating both regression equations into the first-order decay based model for estimating methane generation rates from landfills. CLEEN model values were compared to actual field data from 6 US landfills, and to estimates from LandGEM and IPCC. For 4 of the 6 cases, CLEEN model estimates were the closest to actual. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Preparation of biochar from sewage sludge

    NASA Astrophysics Data System (ADS)

    Nieto, Aurora; María Méndez, Ana; Gascó, Gabriel

    2013-04-01

    Biomass waste materials appropriate for biochar production include crop residues (both field residues and processing residues such as nut shells, fruit pits, bagasse, etc), as well as yard, food and forestry wastes, and animal manures. Biochar can and should be made from biomass waste materials and must not contain unacceptable levels of toxins such as heavy metals which can be found in sewage sludge and industrial or landfill waste. Making biochar from biomass waste materials should create no competition for land with any other land use option—such as food production or leaving the land in its pristine state. Large amounts of agricultural, municipal and forestry biomass are currently burned or left to decompose and release CO2 and methane back into the atmosphere. They also can pollute local ground and surface waters—a large issue for livestock wastes. Using these materials to make biochar not only removes them from a pollution cycle, but biochar can be obtained as a by-product of producing energy from this biomass. Sewage sludge is a by-product from wastewater treatment plants, and contains significant amounts of heavy metals, organic toxins and pathogenic microorganisms, which are considered to be harmful to the environment and all living organisms. Agricultural use, land filling and incineration are commonly used as disposal methods. It was, however, reported that sewage sludge applications in agriculture gives rise to an accumulation of harmful components (heavy metals and organic compounds) in soil. For this reason, pyrolysis can be considered as a promising technique to treat the sewage sludge including the production of fuels. The objective of this work is to study the advantages of the biochar prepared from sewage sludge.

  8. Relationship between recycling rate and air pollution: Waste management in the state of Massachusetts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giovanis, Eleftherios, E-mail: giovanis95@gmail.com

    Highlights: • This study examines the relationship between recycling rate of solid waste and air pollution. • Fixed effects Stochastic Frontier Analysis model with panel data are employed. • The case study is a waste municipality survey in the state of Massachusetts during 2009–2012. • The findings support that a negative relationship between air pollution and recycling. - Abstract: This study examines the relationship between recycling rate of solid waste and air pollution using data from a waste municipality survey in the state of Massachusetts during the period 2009–2012. Two econometric approaches are applied. The first approach is a fixedmore » effects model, while the second is a Stochastic Frontier Analysis (SFA) with fixed effects model. The advantage of the first approach is the ability of controlling for stable time invariant characteristics of the municipalities, thereby eliminating potentially large sources of bias. The second approach is applied in order to estimate the technical efficiency and rank of each municipality accordingly. The regressions control for various demographic, economic and recycling services, such as income per capita, population density, unemployment, trash services, Pay-as-you-throw (PAYT) program and meteorological data. The findings support that a negative relationship between particulate particles in the air 2.5 μm or less in size (PM{sub 2.5}) and recycling rate is presented. In addition, the pollution is increased with increases on income per capita up to $23,000–$26,000, while after this point income contributes positively on air quality. Finally, based on the efficiency derived by the Stochastic Frontier Analysis (SFA) model, the municipalities which provide both drop off and curbside services for trash, food and yard waste and the PAYT program present better performance regarding the air quality.« less

  9. TANK 18-F AND 19-F TANK FILL GROUT SCALE UP TEST SUMMARY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stefanko, D.; Langton, C.

    2012-01-03

    High-level waste (HLW) tanks 18-F and 19-F have been isolated from FTF facilities. To complete operational closure the tanks will be filled with grout for the purpose of: (1) physically stabilizing the tanks, (2) limiting/eliminating vertical pathways to residual waste, (3) entombing waste removal equipment, (4) discouraging future intrusion, and (5) providing an alkaline, chemical reducing environment within the closure boundary to control speciation and solubility of select radionuclides. This report documents the results of a four cubic yard bulk fill scale up test on the grout formulation recommended for filling Tanks 18-F and 19-F. Details of the scale upmore » test are provided in a Test Plan. The work was authorized under a Technical Task Request (TTR), HLE-TTR-2011-008, and was performed according to Task Technical and Quality Assurance Plan (TTQAP), SRNL-RP-2011-00587. The bulk fill scale up test described in this report was intended to demonstrate proportioning, mixing, and transportation, of material produced in a full scale ready mix concrete batch plant. In addition, the material produced for the scale up test was characterized with respect to fresh properties, thermal properties, and compressive strength as a function of curing time.« less

  10. Metal sources and exposures in the homes of young children living near a mining-impacted Superfund site.

    PubMed

    Zota, Ami R; Schaider, Laurel A; Ettinger, Adrienne S; Wright, Robert O; Shine, James P; Spengler, John D

    2011-01-01

    Children living near hazardous waste sites may be exposed to environmental contaminants, yet few studies have conducted multi-media exposure assessments, including residential environments where children spend most of their time. We sampled yard soil, house dust, and particulate matter with aerodynamic diameter <2.5 in 59 homes of young children near an abandoned mining area and analyzed samples for lead (Pb), zinc (Zn), cadmium (Cd), arsenic (As), and manganese (Mn). In over half of the homes, dust concentrations of Pb, Zn, Cd, and As were higher than those in soil. Proximity to mine waste (chat) piles and the presence of chat in the driveway significantly predicted dust metals levels. Homes with both chat sources had Pb, Zn, Cd, and As dust levels two to three times higher than homes with no known chat sources after controlling for other sources. In contrast, Mn concentrations in dust were consistently lower than in soil and were not associated with chat sources. Mn dust concentrations were predicted by soil concentrations and occupant density. These findings suggest that nearby outdoor sources of metal contaminants from mine waste may migrate indoors. Populations farther away from the mining site may also be exposed if secondary uses of chat are in close proximity to the home.

  11. Pollutant loads of surface runoff in Wuhan City Zoo, an urban tourist area.

    PubMed

    Zhao, Jian-wei; Shan, Bao-qing; Yin, Cheng-qing

    2007-01-01

    The pollutant loads of surface runoff in an urban tourist area have been investigated for two years in the Wuhan City Zoo, China. Eight sampling sites, including two woodlands, three animal yards, two roofs and one road, were selected for sampling and study. The results indicate that pollutants ranked in a predictable order of decreasing load (e.g. animal yard > roof > woodland > road), with animal yards acting as the key pollution source in the zoo. Pollutants were transported mainly by particulate form in runoff. Particulate nitrogen and particulate phosphorous accounted on average for 61%, 78% of total pollutant, respectively, over 13 monitored rainfall events. These results indicate the treatment practices should be implemented to improve particulate nutrient removal. Analysis of the M(V) curve indicate that no first flush effect existed in the surface runoff from pervious areas (e.g. woodland, animal ground yard), whereas a first flush effect was evident in runoff from impervious surfaces (e.g. animal cement yard, roof, road).

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The 20-acre White Farm Equipment Dump site is an active landfill near the north border of Charles City in Floyd County, Iowa. Drainage from the site toward the northwest and south feeds into adjacent wetland areas. The Charles City municipal wells, located 700 feet east of the site, obtain water from the deep, confined Cedar Valley aquifer. Additionally, six shallow drinking water wells that draw from an uncontrolled water table are 1,000 feet downgradient from the site. Intermittently since 1971, approximately 650,000 cubic yards of wet scrubber sludges, foundry sands, baghouse dusts, and other industrial wastes were disposed of onsite.more » The primary contaminants of concern affecting the soil, debris, and ground water are VOCs including benzene and toluene; and metals including arsenic, lead, and chromium.« less

  13. Geology beneath and beside the notorious Payatas open dump, Metro Manila, Philippines

    NASA Astrophysics Data System (ADS)

    Tomarong, C.; Arcilla, C.; de Sales, L.; Chua, S.; Garcia, E.; Pamintuan, G.

    2003-04-01

    With a minimum of 6000 tonnes/day municipal waste output, and with NO existing operational sanitary landfill and with incineration illegal, Metro Manila has a very serious solid waste disposal problem. Unsorted municipal waste are being piled in open dumps, the most notorious of which is the Payatas open dump. A recent, tragic garbage-slide in this open dump caused dozens of deaths, news of which were broadcast internationally. Political expediency laced with a lot of corruption, rather than sound science, was the main basis for selecting this site as an open dump. As an example, this dump is situated < 1 km from the Novaliches Watershed Reservation, one of the main sources of drinking water for Metro Manila’s 12 million population! Yet, after dumping operations that have lasted more than 10 years, only recently were the preliminary geologic studies begun. Payatas is not a designed landfill and its untreated leachate is openly polluting the headwaters of the Marikina and Pasig Rivers. In addition, during the summer months, there is always the constant threat of fire due to methane induced burning from the dump, aside from the aerial pollution from dioxins and furans derived from incomplete combustion of municipal solid waste. With limited funding from the Quezon City government, a feasibility study was conducted to assess the methane generation potential of Payatas. This interdisciplinary study comprised bedrock geological studies, topographic mapping of the dump, drilling of the dump to obtain stratigraphic solid waste samples for waste characterization, laying of horizontal methane and dewatering pipes, and preliminary methane flow studies. The waste characterization has highlighted the unusually high organic (especially yard waste) component of the solid waste dumped at Payatas. Waste characterization shows that a significant portion of the waste is plastics. Several cross-sections cut across the dump show that the side slopes of the dump are on the average steeper than the pre-dump slopes. The “bedrock” of the Payatas dump are conglomerate members of the Pleistocene volcaniclastic Guadualupe Formation. Studies are still to be done on the extent of pollution on surface and groundwater in the Payatas environs.

  14. 78 FR 7665 - Safety Zones; Pacific Northwest Grain Handlers Association Facilities; Columbia and Willamette...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-04

    .../122-46'28'' then heading 150 yards to the shoreline ending at 45-38'30'' N/122- 46'25'' W. In essence...'' then heading 150 yards to the shoreline ending at 45- 37'44'' N/122-41'31'' W. In essence, these... heading 150 yards to the shoreline ending at 45-59'00'' N/122-50'01'' W. In essence, these boundaries...

  15. The relationship between residential yard management and neighborhood crime: An analysis from Baltimore City and County

    Treesearch

    Austin Troy; Ashley Nunery; Morgan Grove

    2016-01-01

    We analyzed the relationship between crime and indicators of residential yard management in Baltimore City and County. Data came from a survey we conducted of over one thousand front yards that included more than 40 indicators relating to lawns, trees, shrubs, beds and other features. These indicators were related to point counts of crime at the 150 m scale using a...

  16. What parts of a house and yard landscape are homeowners maintaining for wildfire safety?

    Treesearch

    Christine Vogt; Sarah McCaffrey; Greg Winter

    2010-01-01

    Homeownership can be a lot of work. Interior maintenance and housekeeping; outdoor maintenance and weekly yard work–all part of the drill. The investment of time and money can be substantial depending on the size and condition of the home and acreage, or the amount of vegetation, including deciduous trees and other woody matter in a yard. Homeowners in high fire risk...

  17. Residents' Yard Choices and Rationales in a Desert City: Social Priorities, Ecological Impacts, and Decision Tradeoffs

    NASA Astrophysics Data System (ADS)

    Larson, Kelli L.; Casagrande, David; Harlan, Sharon L.; Yabiku, Scott T.

    2009-11-01

    As a dominant land use in urban ecosystems, residential yards impact water and other environmental resources. Converting thirsty lawns into alternative landscapes is one approach to water conservation, yet barriers such as cultural norms reinforce the traditional lawn. Meanwhile, the complex social and ecological implications of yard choices complicate programs aimed at changing grass and other yard features for particular purposes. In order to better understand individual landscape decisions, we qualitatively examined residents’ rationales for their preferred yard types in the desert metropolis of Phoenix, Arizona. After briefly presenting landscape choices across two survey samples, the dominant reasons for preferences are discussed: appearance, maintenance, environment, recreation, microclimate, familiarity, and health/safety. Three broader analytical themes emerged from these descriptive codes: (1) residents’ desires for attractive, comfortable landscapes of leisure encompassing pluralistic tastes, lifestyles, and perceptions; (2) the association of environmental benefits and impacts with different landscape types involving complex social and ecological tradeoffs; and (3) the cultural legacies evident in modern landscape choices, especially in terms of a dichotomous human-nature worldview among long-time residents of the Phoenix oasis. Given these findings, programs aimed at landscape change must recognize diverse preferences and rationalization processes, along with the perceived versus actual impacts and tradeoffs of varying yard alternatives.

  18. Simulation model for port shunting yards

    NASA Astrophysics Data System (ADS)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  19. Ascaris and hookworm transmission in preschool children from rural Panama: role of yard environment, soil eggs/larvae and hygiene and play behaviours.

    PubMed

    Krause, Rachel J; Koski, Kristine G; Pons, Emérita; Sandoval, Nidia; Sinisterra, Odalis; Scott, Marilyn E

    2015-10-01

    This study explored whether the yard environment and child hygiene and play behaviours were associated with presence and intensity of Ascaris and hookworm in preschool children and with eggs and larvae in soil. Data were collected using questionnaires, a visual survey of the yard, soil samples and fecal samples collected at baseline and following re-infection. The presence of eggs/larvae in soil was associated negatively with water storage (eggs) but positively with dogs (eggs) and distance from home to latrine (larvae). Baseline and re-infection prevalences were: hookworm (28.0%, 3.4%); Ascaris (16.9%, 9.5%); Trichuris (0.9%, 0.7%). Zero-inflated negative binomial regression models revealed a higher baseline hookworm infection if yards had eggs or larvae, more vegetation or garbage, and if the child played with soil. Baseline Ascaris was associated with dirt floor, dogs, exposed soil in yard, open defecation and with less time playing outdoors, whereas Ascaris re-infection was associated with water storage, vegetation cover and garbage near the home and not playing with animals. Our results show complex interactions between infection, the yard environment and child behaviours, and indicate that transmission would be reduced if latrines were closer to the home, and if open defecation and water spillage were reduced.

  20. Discrete event simulation model for external yard choice of import container terminal in a port buffer area

    NASA Astrophysics Data System (ADS)

    Rusgiyarto, Ferry; Sjafruddin, Ade; Frazila, Russ Bona; Suprayogi

    2017-06-01

    Increasing container traffic and land acquisition problem for terminal expansion leads to usage of external yard in a port buffer area. This condition influenced the terminal performance because a road which connects the terminal and the external yard was also used by non-container traffic. Location choice problem considered to solve this condition, but the previous research has not taken account a stochastic condition of container arrival rate and service time yet. Bi-level programming framework was used to find optimum location configuration. In the lower-level, there was a problem to construct the equation, which correlated the terminal operation and the road due to different time cycle equilibrium. Container moves from the quay to a terminal gate in a daily unit of time, meanwhile, it moves from the terminal gate to the external yard through the road in a minute unit of time. If the equation formulated in hourly unit equilibrium, it cannot catch up the container movement characteristics in the terminal. Meanwhile, if the equation formulated in daily unit equilibrium, it cannot catch up the road traffic movement characteristics in the road. This problem can be addressed using simulation model. Discrete Event Simulation Model was used to simulate import container flow processes in the container terminal and external yard. Optimum location configuration in the upper-level was the combinatorial problem, which was solved by Full Enumeration approach. The objective function of the external yard location model was to minimize user transport cost (or time) and to maximize operator benefit. Numerical experiment was run for the scenario assumption of two container handling ways, three external yards, and thirty-day simulation periods. Jakarta International Container Terminal (JICT) container characteristics data was referred for the simulation. Based on five runs which were 5, 10, 15, 20, and 30 repetitions, operation one of three available external yards (external yard - 3) was the optimum result. Apparently, the model confirmed the hypothesis that there was an optimum configuration of the external yard. Nevertheless, the model needs detail elaboration related to the objective function and the optimization constraint. It requires detail validation, in term of service time value, distribution pattern, and arrival rate in each unit server modeled in the next step of the research. The model gave unique and relatively consistent value of each run. It was indicated that the method has a chance to solve the research problem.

  1. Superfund record of decision amendment (EPA Region 5): Allied Chemical and Ironton Coke, Ironton, OH, September 30, 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This decision document, together with the Allied Chemical/Ironton Coke Record of Decision (ROD) dated December 28, 1990, the first Allied Chemical/Ironton Coke ROD Amendment dated July 31, 1995 (ROD Amendment No 1), and the second ROD Amendment dated September 4, 1997 (ROD Amendment No 2), presents the selected remedial action for the Allied Chemical/Ironton Coke site. The remedy selected in the 1990 ROD, 1995 ROD Amendment No. 1, and 1997 ROD Amendment No. 2 for the site is a final remedial action. Through ROD Amendment No. 3 the following components of the selected remedy are being modified: Replace in-situ bioremediationmore » of 457,000 cubic yards of soil in Lagoons 1--4 with hot spot excavation and wetland development; and Replace incineration of Lagoon 5 materials with recycling, treatment, and/or disposal of the K087 listed waste in an approved off-site hazardous waste facility and the use of the remaining material, excluding debris, as an alternative fuel.« less

  2. Water and wastewater minimization plan in food industries.

    PubMed

    Ganjidoust, H; Ayati, B

    2002-01-01

    Iran is one of the countries located in a dry and semi-dry area. Many provinces like Tehran are facing problems in recent years because of less precipitation. For reduction in wastewater treatment cost and water consumption, many research works have been carried out. One of them concerns food industries group, which consumes a great amount of water in different units. For example, in beverage industries, washing of glass bottles seven times requires large amounts of water but use of plastic bottles can reduce water consumption. Another problem is leakage from pipelines, valves, etc. Their repair plays an important role in the wastage of water. The non-polluted wasted water can be used in washing halls, watering green yards, recycling to the process or reusing in cooling towers. In this paper, after a short review of waste minimization plans in food industries, problems concerning water consuming and wastewater producing units in three Iranian food industries have been investigated. At the end, some suggestions have been given for implementing the water and wastewater minimization plan in the companies.

  3. Relationship between recycling rate and air pollution: Waste management in the state of Massachusetts.

    PubMed

    Giovanis, Eleftherios

    2015-06-01

    This study examines the relationship between recycling rate of solid waste and air pollution using data from a waste municipality survey in the state of Massachusetts during the period 2009-2012. Two econometric approaches are applied. The first approach is a fixed effects model, while the second is a Stochastic Frontier Analysis (SFA) with fixed effects model. The advantage of the first approach is the ability of controlling for stable time invariant characteristics of the municipalities, thereby eliminating potentially large sources of bias. The second approach is applied in order to estimate the technical efficiency and rank of each municipality accordingly. The regressions control for various demographic, economic and recycling services, such as income per capita, population density, unemployment, trash services, Pay-as-you-throw (PAYT) program and meteorological data. The findings support that a negative relationship between particulate particles in the air 2.5 μm or less in size (PM2.5) and recycling rate is presented. In addition, the pollution is increased with increases on income per capita up to $23,000-$26,000, while after this point income contributes positively on air quality. Finally, based on the efficiency derived by the Stochastic Frontier Analysis (SFA) model, the municipalities which provide both drop off and curbside services for trash, food and yard waste and the PAYT program present better performance regarding the air quality. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. 33 CFR 165.168 - Safety Zones; Coast Guard Captain of the Port New York Fireworks Displays.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 074°02′23″ W (NAD 1983), located in Federal Anchorage 20-C, about 360 yards east of Liberty Island. (2... (NAD 1983), about 365 yards east of Ellis Island. (3) South Beach, Staten Island Safety Zone: All...°35′11″ N 074°03′42″ W (NAD 1983), about 350 yards east of South Beach, Staten Island. (4) Raritan Bay...

  5. Progress report of southeastern monazite exploration, 1952

    USGS Publications Warehouse

    Overstreet, W.C.; Theobald, P.K.; White, A.M.; Cuppels, N.P.; Caldwell, D.W.; Whitlow, J.W.

    1953-01-01

    Reconnaissance of placer monazite during the field season of 1952 covered 6,600 square miles drained by streams in the western Piedmont of Virginia 5 North Carolina, South Carolina,, and Georgia. Emphasis during this investigation was placed on the area between the Savannah River at the border of South Carolina and Georgia and the Catawba River in North Carolina because it contains most of the placers formerly mined for monaziteo Four other areas along the strike of the monazite-bearing crystalline rocks were also studied, They center around Mt. Airy, N.C., Athens, Ga. Griffin, Ga. and LaGrange, Ga. In the Savannah River Catawba River district, studies indicate that even the highest grade stream deposits of more than 10 million cubic yards of alluvium contain less than 1 pound of monazite per cubic yard. The average grade of the better deposits is about 0 0 5 pound of monazite per cubic yard. Only trace amounts of niobium, tantalum, and tin have been detected in the placers. Tungsten is absent. Locally gold adds a few cents per cubic yard to the value of placer ground. The best deposits range in size from 1 to 5 million cubic yards and contain 1 to 2 pounds of monazite to the cubic yard. Hundreds of placers smaller than 1 million cubic yards exceed 2 pounds of monazite to the cubic yard and locally attain an average of 10 pounds Monazite deposits around Athens, Ga., are similar to the smaller deposits in the central part of the Savannah River - Catawba River district. A few small very low-grade monazite placers were found near Mt. Airy, N.C., Griffin, Ga., and LaGrange Ga., but they are of no economic value. The larger the flood plain and the farther it lies from the source of the stream, the lower is the monazite content of the sediment. Monazite cannot be profitably mined .from the crystalline rocks in the five areas. The alluvial placers are in stream sediments of post-Wisconsin age. Some pre-Wisconsin terrace gravel of small areal extent is exposed but it contains only a small amount of monazite Pre-Wisconsin to early post-Wisconsin colluvial sediments locally contain 2 pounds of monazite to the cubic yard. Mode of presentation of reports covering field work during the seasons of 1951 - 52 is given. No further reconnaissance will be undertaken, in the western monazite belt.

  6. Environmental and childhood lead contamination in the proximity of boat-repair yards in southern Thailand--I: pattern and factors related to soil and household dust lead levels.

    PubMed

    Maharachpong, Nipa; Geater, Alan; Chongsuvivatwong, Virasakdi

    2006-07-01

    High blood lead levels have recently been documented in schoolchildren living in communities adjacent to boat-repair yards in southern Thailand. In this study, the spatial pattern of lead contamination of soil and household dust in an area surrounding several boat-repair yards is described, and household factors associated with elevated dust lead are identified. A cross-sectional spatial study was conducted in a coastal residential area within a distance of 2 km from three major boat-repair yards situated on the east coast of peninsular Thailand. Household dust specimens were collected from an undisturbed position in the residences of children, aged 4-14 years, sampled randomly from all children living in the study area. Soil specimens were obtained from the interstices of a square grid, 70 x 70 m2, superimposed on the area. Geographic coordinates of residence and soil sampling positions were recorded and semivariograms and kriging used to contour the spatial distribution of lead in dust and soil. Environmental lead levels were also modeled in terms of direction and minimum distance from a boat-repair yard and, for household dust lead content, in terms of household variables, including occupation of household members in boat-repair work, type of house construction, and general cleanliness. Household dust and soil lead content ranged from 10 to 3025 mg/kg and from 1 to 7700 mg/kg, respectively. The distribution of soil lead peaked at the location of the boat-repair yards, but outside the yards the distribution was generally below 400 mg/kg and irregular. About 24% of household dust lead specimens were equal to or above 400 mg/kg, but showed significant decrease with increasing distance from the boat-repair yards, at rates of between 7% and 14% per 100 m. In houses where a family member was a worker in one of the major boatyards and in houses where occasional repair of small boats was undertaken, household dust lead levels were significantly elevated, by 65% (95% CI: 18-130%) and 31% (95% CI: 5-63%), respectively. Siting of boat-repair yards at a distance from residential areas and measures to reduce the spread of lead-containing dust are recommended to alleviate the problem of elevated household dust lead levels.

  7. Changes of parameters during composting of bio-waste collected over four seasons.

    PubMed

    Hanc, Ales; Ochecova, Pavla; Vasak, Filip

    2017-07-01

    This study investigated the evolution of several main parameters during the composting of separately collected household bio-waste originating from urban settlements (U-bio-waste) and family houses (F-bio-waste) from four climate seasons. When comparing both types of composts, U-bio-waste compost contained a higher amount of nutrients, however F-bio-waste compost was characterized by greater yield, greater availability of phosphorus and magnesium, and faster stability. In terms of seasons, compost from bio-waste collected in spring contained the highest amount of nutrients, reflecting the high content of nutrients in plant feedstock. Dissolved organic carbon and pH in U- and F-bio-waste compost, respectively, frequently showed close relationships with other parameters. The seasonal variations of most of the parameters in the composts were found to be lower compared to the variations observed in the feedstocks. The greatest seasonal variation was found in nitrate nitrogen, which is the reason for the more frequent analysis of this parameter.

  8. Urban farming model in South Jakarta

    NASA Astrophysics Data System (ADS)

    Indrawati, E.

    2018-01-01

    The development of infrastructure rapidly, large of population and large of urbanization. Meanwhile, agricultural land is decreasing and agricultural production continues to decline. The productive crops is needed for consumption and it is also to improve the environment from oxygen provisioning, antidote to air pollution and to improve soil conditions. The use of yard land for horticultural crops (vegetables, fruits and ornamental plants), spices, medicines, herbs etc. can benefit for the owners of the yard particularly and the general public. The purpose of this research is to identify the model of home yard utilization, mosque yard, office, school, urban park and main road and sub main road, which can improve environmental quality in Pesanggrahan district. The method of analysis used descriptive analysis method by observation. Then analyzed the percentage of the use of yard with productive crops as urban farming. The results showed that the most productive crops were planted in Kelurahan Pesanggrahan 67% which compared with in Kelurahan Ulujami 47%, and in Kelurahan Petukangan Utara 27%. The most types of productive crops were grown as fruit trees and vegetable crops.

  9. Automatic Adviser on stationary devices status identification and anticipated change

    NASA Astrophysics Data System (ADS)

    Shabelnikov, A. N.; Liabakh, N. N.; Gibner, Ya M.; Pushkarev, E. A.

    2018-05-01

    A task is defined to synthesize an Automatic Adviser to identify the automation systems stationary devices status using an autoregressive model of changing their key parameters. An applied model type was rationalized and the research objects monitoring process algorithm was developed. A complex of mobile objects status operation simulation and prediction results analysis was proposed. Research results are commented using a specific example of a hump yard compressor station. The work was supported by the Russian Fundamental Research Fund, project No. 17-20-01040.

  10. BARBEQUE PIT AND PLAYHOUSE IN (REAR) YARD, LOOKING SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    BARBEQUE PIT AND PLAYHOUSE IN (REAR) YARD, LOOKING SOUTH - Irvine Ranch Agricultural Headquarters, Carillo Tenant House, Southwest of Intersection of San Diego & Santa Ana Freeways, Irvine, Orange County, CA

  11. Comparative assessment of heavy metals content during the composting and vermicomposting of Municipal Solid Waste employing Eudrilus eugeniae.

    PubMed

    Soobhany, Nuhaa; Mohee, Romeela; Garg, Vinod Kumar

    2015-05-01

    This study was undertaken to have comparative assessment of heavy metals content during composting and vermicomposting processing of Municipal Solid Waste (MSW). Six scenarios were set up in which three experiments were for composting (controls) denoted as S1 for food waste, S2 for paper waste and S3 for yard waste and the corresponding replicates for vermicomposting processes were S4, S5 and S6. Vermicomposting caused significant reduction in Cd (43.3-73.5%), Cr (11.3-52.8%), Cu (18.9-62.5%), Co (21.4-47.6%), Zn (34.6%) and Ni (19.9-49.6%) compared to composting which showed a progressive increase. Addition of worms did not show any effect on Fe and Mn, most probably from the genesis of organic-bound complexes. The efficacy of utilizing Eudrilus eugeniae was indicated by the high values of bioconcentration factors (BCFs) which were in the order of Cd>Ni>Cu>Co>Cr>Zn and the increase amount of these metals in the earthworms' tissue after the vermicomposting processes. Different values of BCFs were obtained for different heavy metals and this accounted that earthworms exert different metabolic mechanisms. Regression analysis of the reduction percentages (R) in relation to BCF showed that RCdtot.S6, RCrtot.S5 and RCutot.S6 were significantly correlated with BCFCd.S6, BCFCr.S5 and BCFCu.S6 respectively. Thus, in comparison to simple composting processes, data analysis suggested the feasibility of inoculating E. eugeniae to MSW in order to mitigate the content of toxic heavy metals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Ticks

    MedlinePlus

    ... Tweet Share Compartir PREVENT BITES Avoid ticks on people, on pets and in the yard. More REMOVE TICKS Find ... Follow the Steps Ticks Home Avoiding ticks On people On pets In the yard Removing a tick Symptoms of ...

  13. Superfund record of decision (EPA Region 7): St. Louis Airport/HHS/Futura Coatings Co. , St. Louis County, MO, August 27, 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1999-03-01

    This document presents the selected remedial action for the cleanup of wastes related to Manhattan Engineering District/Atomic Energy Commission (MED/AEC) operations in accessible soils and ground water at the St. Louis Downtown Site (SLDS). The main components of the selected remedial action include: Excavation and off-site disposal of approximately 65,000 cubic meters (85,000 cubic yards) (in-situ) contaminated soil; and No remedial action is required for ground water beneath the site. Perimeter monitoring of the ground water in the Mississippi River alluvial aquifer, designated as the hydrostratigraphic B Unit, will be performed and the need for ground water remediation will bemore » evaluated as part of the periodic reviews performed for the site.« less

  14. FOUNDRY LANDSCAPE LOOKING NORTHWEST FROM MALLEABLE STOCK YARD CRANE SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FOUNDRY LANDSCAPE LOOKING NORTHWEST FROM MALLEABLE STOCK YARD CRANE SHOWING THE MALLEABLE ANNEALING BUILDING AND THE BRASS FOUNDRY. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  15. FOUNDRY LANDSCAPE LOOKING SOUTHWEST FROM MALLEABLE STOCK YARD CRANE SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FOUNDRY LANDSCAPE LOOKING SOUTHWEST FROM MALLEABLE STOCK YARD CRANE SHOWING CRANE RAILS, GREY IRON CUPOLA AND EMISSION RECOVERY SYSTEM. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  16. FOUNDRY LANDSCAPE LOOKING WESTSOUTHWEST FROM MALLEABLE STOCK YARD CRANE SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FOUNDRY LANDSCAPE LOOKING WEST-SOUTHWEST FROM MALLEABLE STOCK YARD CRANE SHOWING SHED ROOF OF OLD MALLEABLE CUPOLA CHARGER. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  17. 7 CFR 1437.309 - Turfgrass sod.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... sod shall be a square yard. (d) Turfgrass sod having any value shall be considered as worth full value... information to CCC regarding the average number of square yards per acre and all unharvested areas. ...

  18. 7 CFR 1437.309 - Turfgrass sod.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... sod shall be a square yard. (d) Turfgrass sod having any value shall be considered as worth full value... information to CCC regarding the average number of square yards per acre and all unharvested areas. ...

  19. 7 CFR 1437.309 - Turfgrass sod.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... sod shall be a square yard. (d) Turfgrass sod having any value shall be considered as worth full value... information to CCC regarding the average number of square yards per acre and all unharvested areas. ...

  20. Cell block four exercise yard with original passage to cell ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Cell block four exercise yard with original passage to cell re-exposed, looking from the baseball field, facing west, with scale - Eastern State Penitentiary, 2125 Fairmount Avenue, Philadelphia, Philadelphia County, PA

  1. Halfthrough girder over entrance to scrap yard at western end ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Half-through girder over entrance to scrap yard at western end of trestle, looking NW. - Pennsylvania Railroad, French Creek Trestle, Spanning French Creek, north of Paradise Street, Phoenixville, Chester County, PA

  2. Superfund Record of Decision (EPA Region 7): Vogel Paint and Wax, Maurice, IA. (First remedial action), September 1989. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-09-20

    The Vogel Paint and Wax (VPW) site is an approximately two-acre disposal area two miles southwest of the town of Maurice, in Sioux County, Iowa. Adjacent land uses are primarily agricultural; however, several private residences are within one-quarter mile of the site. A surficial sand and gravel aquifer underlies the site and supplies nearby private wells and the Southern Sioux County Rural Water System, located a mile and one half southeast of the site. Paint sludge, resins, solvents, and other paint-manufacturing wastes were disposed of at the site between 1971 and 1979. VPW records indicate that approximately 43,000 gallons ofmore » aliphatic and aromatic hydrocarbons and 6,000 pounds of metals waste were buried at the site. The primary contaminants of concern affecting the soil and ground water are VOCs including benzene, toluene, and xylenes; and metals including chromium and lead. The selected remedial action for this site includes excavation of contaminated soil and separation of solid and liquid wastes; onsite bioremediation of 3,000 cubic yards of the contaminated soil in a fully contained surface impoundment unit, or onsite thermal treatment if soil contains high metal content; and stabilization of treated soil, if necessary to prevent leaching of metals, followed by disposal in the excavated area.« less

  3. CHICKEN COOP BEHIND FENCED YARD AND (REAR) OF BARBEQUE PIT, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CHICKEN COOP BEHIND FENCED YARD AND (REAR) OF BARBEQUE PIT, LOOKING NORTH - Irvine Ranch Agricultural Headquarters, Carillo Tenant House, Southwest of Intersection of San Diego & Santa Ana Freeways, Irvine, Orange County, CA

  4. Railroad Classification Yard Technology Manual. Volume III. Freight Car Rollability

    DOT National Transportation Integrated Search

    1981-07-01

    The report presents a survey of rolling resistance research, histograms of rolling resistance from five yards, a statistical regression analysis of causal factors affecting rolling resistance, procedures for constructing a rolling resistance histogra...

  5. 9. Fuel tanks engine piping yard equipment details, sheet 94 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Fuel tanks engine piping yard equipment details, sheet 94 of 130 - Naval Air Station Fallon, Fuel Tanks, 800 Complex, off Carson Road near intersection of Pasture & Berney Roads, Fallon, Churchill County, NV

  6. Simulating settlement during waste placement at a landfill with waste lifts placed under frozen conditions.

    PubMed

    Van Geel, Paul J; Murray, Kathleen E

    2015-12-01

    Twelve instrument bundles were placed within two waste profiles as waste was placed in an operating landfill in Ste. Sophie, Quebec, Canada. The settlement data were simulated using a three-component model to account for primary or instantaneous compression, secondary compression or mechanical creep and biodegradation induced settlement. The regressed model parameters from the first waste layer were able to predict the settlement of the remaining four waste layers with good agreement. The model parameters were compared to values published in the literature. A MSW landfill scenario referenced in the literature was used to illustrate how the parameter values from the different studies predicted settlement. The parameters determined in this study and other studies with total waste heights between 15 and 60 m provided similar estimates of total settlement in the long term while the settlement rates and relative magnitudes of the three components varied. The parameters determined based on studies with total waste heights less than 15m resulted in larger secondary compression indices and lower biodegradation induced settlements. When these were applied to a MSW landfill scenario with a total waste height of 30 m, the settlement was overestimated and provided unrealistic values. This study concludes that more field studies are needed to measure waste settlement during the filling stage of landfill operations and more field data are needed to assess different settlement models and their respective parameters. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Closure Report for Corrective Action Unit 536: Area 3 Release Site, Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    Corrective Action Unit (CAU) 536 is located in Area 3 of the Nevada Test Site. CAU 536 is listed in the Federal Facility Agreement and Consent Order of 1996 as Area 3 Release Site, and comprises a single Corrective Action Site (CAS): {sm_bullet} CAS 03-44-02, Steam Jenny Discharge The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CAS 03-44-02 is clean closure. Closure activities included removing and disposing of total petroleum hydrocarbon (TPH)- and polyaromatic hydrocarbon (PAH)-impacted soil, soil impacted with plutonium (Pu)-239, and concrete pad debris. CAU 536 was closed in accordance with the NDEP-approved CAU 536more » Corrective Action Plan (CAP), with minor deviations as approved by NDEP. The closure activities specified in the CAP were based on the recommendations presented in the CAU 536 Corrective Action Decision Document (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2004). This Closure Report documents CAU 536 closure activities. During closure activities, approximately 1,000 cubic yards (yd3) of hydrocarbon waste in the form of TPH- and PAH-impacted soil and debris, approximately 8 yd3 of Pu-239-impacted soil, and approximately 100 yd3 of concrete debris were generated, managed, and disposed of appropriately. Additionally, a previously uncharacterized, buried drum was excavated, removed, and disposed of as hydrocarbon waste as a best management practice. Waste minimization techniques, such as the utilization of laboratory analysis to characterize and classify waste streams, were employed during the performance of closure« less

  8. Solid waste management in Linamon, Lanao del Norte

    NASA Astrophysics Data System (ADS)

    Paragoso, Glaiza P.; Sapar, Cherine Mae A.; Magsayo, Joy R.; Lahoylahoy, Myrna E.; Guarin, Rica Mae B.

    2018-01-01

    In this modern world, Solid Waste Management is very important in maintaining a high quality of life so humans must manage and store waste efficiently and safely. Almost every day each household generates garbage or wastes. People throw things improperly without knowing the consequences. The main objective of the study was to assess the residents' Solid Waste Management. Specifically, it aimed to answer the following questions: What is the profile of the respondents in terms of age, gender, educational attainment, occupation, monthly income, no. of household member; What is the knowledge of the respondents about Natural Environment?; How do respondents disposed garbage from the household?; What is the level of the respondents concern about proper waste management?; What is the willingness of the respondents to participate in proper Solid Waste Management?; What is the attitude of the respondents towards the Solid Waste Management? The said study was conducted at the Municipality of Linamon, which is a 5th class municipality located at the Eastern Gateway to Lanao del Norte, a south western Province of Northern Mindanao in the Philippines. The study was conducted in the 8 barangays of the Municipality of Linamon, namely: Bosque, Larapan, Mago-ong, Napo, Poblacion, Purakan, Robocon, and Samburon. The Municipality has 3 urban barangays and 4 rural barangays. The study revealed that most of the respondents interviewed were housewives. Out of 313 respondents, 67.10 % did not understand the term natural environment, with major issue currently affecting natural environment as "household garbage'. The respondents dispose the yard trimmings and papers through burning. The plastic and glass is disposed through the garbage truck. The metals and damaged home appliances were disposed by selling it to the junk shop. The respondents disposed their garbage into an open container specifically in a sack, collected by garbage trucks. The study also revealed that the respondents were highly concerned about waste management and willing to participate in proper solid waste management, with attitudes towards solid waste management as highly positive. The researchers recommend initiating educational campaigns for the general public to raise awareness of the natural environment in order to fully understand the term. Incorporate environmental education into school curriculum to raise awareness and develop environmental attitudes in the large youth community.

  9. Tethered Swimming Test: Reliability and the Association to Swimming Performance and Land-based Anaerobic Performance.

    PubMed

    Nagle Zera, Jacquelyn; Nagle, Elizabeth F; Nagai, Takashi; Lovalekar, Mita; Abt, John P; Lephart, Scott M

    2018-02-14

    The purpose of this study was three-fold: (a) to examine the test-retest reliability of a 30 second maximal tethered freestyle swimming test (TST), (b) to assess the validity of the TST by examining the association to sprint swimming performance and, (c) to examine the associations between a swim-specific and land-based measure of anaerobic performance. A total of twenty-nine male and female swimmers were recruited to participate in the study. Each participant completed a Wingate Anaerobic cycling test (WAnT), two or four TST, and a 22.9 meter (25 yard), 45.7 meter (50 yard), and 91.4 meter (100 yard) maximal freestyle performance swims (PS). Mean and peak force (Fmean, Fpeak) were recorded for both the WAnT and TST, and average swimming velocity and time were recorded for the PS. Additionally, physiological and perceptual measures were recorded immediate post exercise for all tests. The results of the present investigation showed strong intersession and intrasession reliability (R= 0.821-0.975; p<0.001) for force parameters of the TST. Moderate correlations were found between Fmean and PS time and velocity of all distances, with slightly weaker correlations between Fpeak and the 22.9 meter (time and velocity) and 45.7 meter (velocity) PS. Finally, moderate correlations were found for Fmean and Fpeak of the TST and WAnT. This study demonstrated that the TST is a reliable measure, with moderate association to swimming performance, producing similar physiological responses compared to free swimming. Therefore, future research shoulSd focus on investigating the potential benefits of utilizing the TST as a regular assessment tool as a part of a competitive swimming training program to track adaptations and inform training decisions.

  10. Defense.gov Special Report: Washington Navy Yard Shooting Review

    Science.gov Websites

    Actions After Navy Yard Shooting Six months after a disturbed federal contractor shot 12 fellow workers to Advocate General List of Actions Press Releases Statement by the President One Year After Shooting

  11. FOUNDRY LANDSCAPE LOOKING WESTNORTHWEST FROM MALLEABLE STOCK YARD CRANE, SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FOUNDRY LANDSCAPE LOOKING WEST-NORTHWEST FROM MALLEABLE STOCK YARD CRANE, SHOWING CRANE MOTOR AND MALLEABLE CUPOLAS WITH OPEN TOPS AND EMISSION RECOVERY DUCTS. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  12. 18. Yards & Docks Drawing 112,447 (463A1) (1931), 'Battery Overhaul ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Yards & Docks Drawing 112,447 (463-A-1) (1931), 'Battery Overhaul Bldg., Acid Mixing Plant & Misc. Details' - Mare Island Naval Shipyard, Acid Mixing Facility, California Avenue & E Street, Vallejo, Solano County, CA

  13. 24. OVERVIEW OF SAR3 AREA, SHOWING SWITCH RACK, SERVICE YARD, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. OVERVIEW OF SAR-3 AREA, SHOWING SWITCH RACK, SERVICE YARD, WAREHOUSE, CARPENTER SHOP, AND STORAGE SHED. VIEW TO SOUTH-SOUTHEAST. PANORAMA 2/2. - Santa Ana River Hydroelectric System, Redlands, San Bernardino County, CA

  14. Railroad Classification Yard Technology : A Survey and Assessment

    DOT National Transportation Integrated Search

    1977-01-01

    This report documents a survey and assessment of the current state of the art in rail freight-car classification yard technology. The major objective was the identification of research and development necessary for technological improvements in railr...

  15. 75 FR 34205 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-16

    ... cars used to haul ore from the mine at Ray Mine yard, in Ray, Arizona, to the Hayden smelter yard in... these proceedings by submitting written views, data, or comments. FRA does not anticipate scheduling a...

  16. 26. NORTHERN VIEW OF ORE YARD WITH ORE BRIDGES IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. NORTHERN VIEW OF ORE YARD WITH ORE BRIDGES IN THE BACKGROUND. BLAST FURNACES ALONG THE RIGHT SIDE. (Martin Stupich) - U.S. Steel Duquesne Works, Blast Furnace Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  17. Data acquisition and PV module power production in upgraded TEP/AzRISE solar test yard

    NASA Astrophysics Data System (ADS)

    Bennett, Whit E.; Fishgold, Asher D.; Lai, Teh; Potter, Barrett G.; Simmons-Potter, Kelly

    2017-08-01

    The Tucson Electric Power (TEP)/University of Arizona AzRISE (Arizona Research Institute for Solar Energy) solar test yard is continuing efforts to improve standardization and data acquisition reliability throughout the facility. Data reliability is ensured through temperature-insensitive data acquisition devices with battery backups in the upgraded test yard. Software improvements allow for real-time analysis of collected data, while uploading to a web server. Sample data illustrates high fidelity monitoring of the burn-in period of a polycrystalline silicon photovoltaic module test string with no data failures over 365 days of data collection. In addition to improved DAQ systems, precision temperature monitoring has been implemented so that PV module backside temperatures are routinely obtained. Weather station data acquired at the test yard provides local ambient temperature, humidity, wind speed, and irradiance measurements that have been utilized to enable characterization of PV module performance over an extended test period

  18. Hazmat transport: a methodological framework for the risk analysis of marshalling yards.

    PubMed

    Cozzani, Valerio; Bonvicini, Sarah; Spadoni, Gigliola; Zanelli, Severino

    2007-08-17

    A methodological framework was outlined for the comprehensive risk assessment of marshalling yards in the context of quantified area risk analysis. Three accident typologies were considered for yards: (i) "in-transit-accident-induced" releases; (ii) "shunting-accident-induced" spills; and (iii) "non-accident-induced" leaks. A specific methodology was developed for the assessment of expected release frequencies and equivalent release diameters, based on the application of HazOp and Fault Tree techniques to reference schemes defined for the more common types of railcar vessels used for "hazmat" transportation. The approach was applied to the assessment of an extended case-study. The results evidenced that "non-accident-induced" leaks in marshalling yards represent an important contribution to the overall risk associated to these zones. Furthermore, the results confirmed the considerable role of these fixed installations to the overall risk associated to "hazmat" transportation.

  19. Translating landfill methane generation parameters among first-order decay models.

    PubMed

    Krause, Max J; Chickering, Giles W; Townsend, Timothy G

    2016-11-01

    Landfill gas (LFG) generation is predicted by a first-order decay (FOD) equation that incorporates two parameters: a methane generation potential (L 0 ) and a methane generation rate (k). Because non-hazardous waste landfills may accept many types of waste streams, multiphase models have been developed in an attempt to more accurately predict methane generation from heterogeneous waste streams. The ability of a single-phase FOD model to predict methane generation using weighted-average methane generation parameters and tonnages translated from multiphase models was assessed in two exercises. In the first exercise, waste composition from four Danish landfills represented by low-biodegradable waste streams was modeled in the Afvalzorg Multiphase Model and methane generation was compared to the single-phase Intergovernmental Panel on Climate Change (IPCC) Waste Model and LandGEM. In the second exercise, waste composition represented by IPCC waste components was modeled in the multiphase IPCC and compared to single-phase LandGEM and Australia's Solid Waste Calculator (SWC). In both cases, weight-averaging of methane generation parameters from waste composition data in single-phase models was effective in predicting cumulative methane generation from -7% to +6% of the multiphase models. The results underscore the understanding that multiphase models will not necessarily improve LFG generation prediction because the uncertainty of the method rests largely within the input parameters. A unique method of calculating the methane generation rate constant by mass of anaerobically degradable carbon was presented (k c ) and compared to existing methods, providing a better fit in 3 of 8 scenarios. Generally, single phase models with weighted-average inputs can accurately predict methane generation from multiple waste streams with varied characteristics; weighted averages should therefore be used instead of regional default values when comparing models. Translating multiphase first-order decay model input parameters by weighted average shows that single-phase models can predict cumulative methane generation within the level of uncertainty of many of the input parameters as defined by the Intergovernmental Panel on Climate Change (IPCC), which indicates that decreasing the uncertainty of the input parameters will make the model more accurate rather than adding multiple phases or input parameters.

  20. Physiological assessment of deer populations by analysis of urine in snow

    USGS Publications Warehouse

    DelGiudice, G.D.; Mech, L.D.; Seal, U.S.

    1989-01-01

    We compared the nutritional status of free-ranging white-tailed deer (Odocoileus virginianus) in 3 natural yards and 1 yard where deer were supplementally fed from 1 January to 31 March 1985 in northeastern Minnesota. We monitored deer nutritonal status by sequential collection and chemical analysis of urine in snow (snow-urine) for urea nitrogen (U), sodium (Na), potassium (K), calcium (Ca), and phosphorus (P). Dilution of urine by snow was corrected by comparing these data as ratios to creatinine (C). All deer remained in an early phase of undernutrition; however, declining trends of U:C, Na:C, and K:C in 2 natural yards indicated increasingly inadequate nutrition as winter progressed. Unaltered values of these ratios and P.C in snow-urine collected from the third natural yard reflected stable levels of nutrient availability. Significant (P < 0.05) elevations of Na:C, K:C, and P:C in 2 natural yards with similar snow regimes suggested initiation of nutritional recovery in deer during late March. In contrast, deep snow in the third natural yard restricted feeding activity and was associated with ratios that remained diminished. Elevated U:C, Na:C, and K:C provided physiological evidence of the higher nutritional status of supplementally fed deer throughout winter and their ability to increase nutrient intake during late March despite prolonged deep snow cover. Frequent and quantitative assessments of the physiological status of deer by snow-urine analysis provided an improved understanding of the relationship between snow cover and the nutritional well-being of these deer.

Top