Sample records for years laboratory tests

  1. An analysis of reference laboratory (send out) testing: an 8-year experience in a large academic medical center.

    PubMed

    MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent

    2004-01-01

    Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.

  2. Electromedical devices test laboratories accreditation

    NASA Astrophysics Data System (ADS)

    Murad, C.; Rubio, D.; Ponce, S.; Álvarez Abri, A.; Terrón, A.; Vicencio, D.; Fascioli, E.

    2007-11-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University.

  3. Crime Laboratory Proficiency Testing Research Program.

    ERIC Educational Resources Information Center

    Peterson, Joseph L.; And Others

    A three-year research effort was conducted to design a crime laboratory proficiency testing program encompassing the United States. The objectives were to: (1) determine the feasibility of preparation and distribution of different classes of physical evidence; (2) assess the accuracy of criminalistics laboratories in the processing of selected…

  4. [Economic impact of external laboratory test].

    PubMed

    Takura, Tomoyuki

    2006-11-01

    The realities of the spread and the aim of the introduction, and an economical influence of an external laboratory tests were researched. As a result, 90% or more the ratio to have consigned the external whole became clear. But it is preferable to correspond about inspection item of about 70% in own facilities because of the characteristic of the medical institution and the inspection item. Moreover, when correct the unbridgeable gulf of characteristic of the realities of spread of present external laboratory tests inspection and the ranging of ideal external laboratory tests inspection that specialist thinks about, the needed medical payment was thought that the investment of about 50 billion yen a year was necessary to expand the inspection in own facilities, by calculated based on the stochastic model.

  5. Use of laboratory testing for genital chlamydial infection in Norway.

    PubMed Central

    Aavitsland, P

    1993-01-01

    OBJECTIVE--To assess the use of laboratory tests for genital chlamydial infection in Norway. DESIGN--Questionnaire survey of general practitioners' practice in chlamydial testing, retrospective survey of laboratory records, 1986-91, and prospective study of testing in one laboratory during four weeks. SETTING--All 18 microbiological laboratories in Norway (4.2 million population), including one serving all doctors in Vestfold county (0.2 million population). SUBJECTS--302 general practitioners. MAIN MEASURES--GPs' routine practice, methods used for testing, 1986-91, and sex specific and age group specific testing in 1991. RESULTS--201(69%) GPs replied to the questionnaire: 101(51%) would test all women younger than 25 years at routine pelvic examination, 107(54%) all girls at first pelvic examination, 131(66%) all pregnant women, and 106(54%) all men whose female partner had urogenital complaints. Nationwide in 1986, 122,000 tests were performed (2.9 per 100 population); 10% were positive and 51% were cell culture tests. In 1991, 341,000 tests were performed (8.0 per 100 population); 4.5% were positive and 15% were cell culture tests. 13,184 tests were performed in Vestfold in 1991 (6.6 per 100 population). The age group specific rates (per 100 population) among women were: age 15-19 years, 22.0(95% confidence interval 18.2 to 25.8); 20-24 years, 47.2(42.1 to 52.3); 25-29 years, 42.3(37.1 to 47.5); 30-34 years, 29.8(25.4 to 34.2); and 35-39 years, 12.5(9.5 to 15.5). CONCLUSIONS--GPs use liberal indications for testing. The dramatic increase in testing, especially by enzyme immunoassays, in populations with a low prevalence of infection results in low cost effectiveness and low predictive value of positive tests, which in women over 29 years is estimated as 17-36%. IMPLICATIONS--Doctors should be educated about the limitations of enzyme immunoassays in screening low prevalence populations, and laboratories should apply a confirmatory test to specimens testing

  6. Cookstove Laboratory Research - Fiscal Year 2016 Report ...

    EPA Pesticide Factsheets

    This report provides an overview of the work conducted by the EPA cookstove laboratory research team in Fiscal Year 2016. The report describes research and activities including (1) ISO standards development, (2) capacity building for international testing and knowledge centers, (3) laboratory assessments of cookstove systems, (4) journal publications, and (5) cookstove events. The U.S. Environmental Protection Agency’s (EPA’s) cookstove laboratory research program was first developed to assist the EPA-led Partnership for Clean Indoor Air and is now part of the U.S. Government’s commitment to the Global Alliance for Clean Cookstoves (the Alliance). Goals of the program are to: (1) support the development of testing protocols and standards for cookstoves through ISO (International Organization for Standardization) TC (Technical Committee) 285: Clean Cookstoves and Clean Cooking Solutions, (2) support the development of international Regional Testing and Knowledge Centers (many sponsored by the Alliance) for scientifically evaluating and certifying cookstoves to international standards, and (3) provide an independent source of data to Alliance partners. This work supports EPA’s mission to protect human health and the environment. Household air pollution, mainly from solid-fuel cookstoves in the developing world, is estimated to cause approximately 4 million premature deaths per year, and emissions of black carbon and other pollutants from cookstoves aff

  7. Cookstove Laboratory Research - Fiscal Year 2016 Report

    EPA Science Inventory

    This report provides an overview of the work conducted by the EPA cookstove laboratory research team in Fiscal Year 2016. The report describes research and activities including (1) ISO standards development, (2) capacity building for international testing and knowledge centers, ...

  8. [Laboratory accreditation and proficiency testing].

    PubMed

    Kuwa, Katsuhiko

    2003-05-01

    ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.

  9. Lipid and lipoprotein testing in resource-limited laboratories.

    PubMed

    Myers, Gary L

    2003-01-01

    The role of total cholesterol (TC) and lipoproteins in the assessment of coronary heart disease (CHD) is firmly established from population and intervention studies. Total and low-density lipoprotein cholesterol (LDLC) levels are positively associated with CHD, and high-density lipoprotein cholesterol (HDLC) levels are negatively associated with CHD. Efforts to identify and treat people at increased risk based on cholesterol and lipoprotein levels have led to more lipid testing and the need for very reliable test results. Thus, quality laboratory services are an essential component of healthcare delivery and play a vital role in any strategy to reduce morbidity and mortality from CHD. In laboratories with limited resources, establishing laboratory capability to measure CHD risk markers may be a considerable challenge. Laboratories face problems in selecting proper techniques, difficulties in equipment availability and maintenance, and shortage of supplies, staffing, and supervision. The Centers for Disease Control and Prevention (CDC) has been providing technical assistance for more than 30 years to laboratories that measure lipids and lipoproteins and is willing to provide technical assistance as needed for other laboratories to develop this capability. CDC can provide technical assistance to establish lipid and lipoprotein testing capability to support a CHD public health program in areas with limited laboratory resources. This assistance includes: selecting a suitable testing instrument; providing training for laboratory technicians; establishing a simple quality control plan; and instructing staff on how to prepare frozen serum control materials suitable for assessing accuracy of lipid and lipoprotein testing.

  10. Use of proficiency test performance to determine clinical laboratory director qualifications.

    PubMed

    Howanitz, P J

    1988-04-01

    Many activities and policies influence laboratory test quality. Proficiency test results are one measure of laboratory quality, and during the past 25 years, five studies have examined the relationship of laboratory director educational requirements to proficiency test results. Data from three studies support the association between director qualifications and quality as measured by proficiency test performance, whereas no relationship was found in the other two studies. Possible reasons for conflicting results include differences in database size and demographics; in addition, proficiency test results may be inappropriate, although widely used, as the sole measure of laboratory director performance.

  11. Managing demand for laboratory tests: a laboratory toolkit.

    PubMed

    Fryer, Anthony A; Smellie, W Stuart A

    2013-01-01

    Healthcare budgets worldwide are facing increasing pressure to reduce costs and improve efficiency, while maintaining quality. Laboratory testing has not escaped this pressure, particularly since pathology investigations cost the National Health Service £2.5 billion per year. Indeed, the Carter Review, a UK Department of Health-commissioned review of pathology services in England, estimated that 20% of this could be saved by improving pathology services, despite an average annual increase of 8%-10% in workload. One area of increasing importance is managing the demands for pathology tests and reducing inappropriate requesting. The Carter Review estimated that 25% of pathology tests were unnecessary, representing a huge potential waste. Certainly, the large variability in levels of requesting between general practitioners suggests that inappropriate requesting is widespread. Unlocking the key to this variation and implementing measures to reduce inappropriate requesting would have major implications for patients and healthcare resources alike. This article reviews the approaches to demand management. Specifically, it aims to (a) define demand management and inappropriate requesting, (b) assess the drivers for demand management, (c) examine the various approaches used, illustrating the potential of electronic requesting and (d) provide a wider context. It will cover issues, such as educational approaches, information technology opportunities and challenges, vetting, duplicate request identification and management, the role of key performance indicators, profile composition and assessment of downstream impact of inappropriate requesting. Currently, many laboratories are exploring demand management using a plethora of disparate approaches. Hence, this review seeks to provide a 'toolkit' with the view to allowing laboratories to develop a standardised demand management strategy.

  12. Quality in laboratory medicine: 50years on.

    PubMed

    Plebani, Mario

    2017-02-01

    The last 50years have seen substantial changes in the landscape of laboratory medicine: its role in modern medicine is in evolution and the quality of laboratory services is changing. The need to control and improve quality in clinical laboratories has grown hand in hand with the growth in technological developments leading to an impressive reduction of analytical errors over time. An essential cause of this impressive improvement has been the introduction and monitoring of quality indicators (QIs) such as the analytical performance specifications (in particular bias and imprecision) based on well-established goals. The evolving landscape of quality and errors in clinical laboratories moved first from analytical errors to all errors performed within the laboratory walls, subsequently to errors in laboratory medicine (including errors in test requesting and result interpretation), and finally, to a focus on errors more frequently associated with adverse events (laboratory-associated errors). After decades in which clinical laboratories have focused on monitoring and improving internal indicators of analytical quality, efficiency and productivity, it is time to shift toward indicators of total quality, clinical effectiveness and patient outcomes. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Laboratory testing in hyperthyroidism.

    PubMed

    Grebe, Stefan K G; Kahaly, George J

    2012-09-01

    The clinical diagnosis of hypo- or hyperthyroidism is difficult (full text available online: http://education.amjmed.com/pp1/272). Clinical symptoms and signs are often non-specific, and there is incomplete correlation between structural and functional thyroid gland changes. Laboratory testing is therefore indispensible in establishing the diagnosis of thyrotoxicosis. Similar considerations apply to treatment monitoring. Laboratory testing also plays a crucial role in establishing the most likely cause for a patient's hyperthyroidism. Finally, during pregnancy, when isotopic scanning is relatively contraindicated and ultrasound is more difficult to interpret, laboratory testing becomes even more important. Copyright © 2012. Published by Elsevier Inc.

  14. Duplicate laboratory test reduction using a clinical decision support tool.

    PubMed

    Procop, Gary W; Yerian, Lisa M; Wyllie, Robert; Harrison, A Marc; Kottke-Marchant, Kandice

    2014-05-01

    Duplicate laboratory tests that are unwarranted increase unnecessary phlebotomy, which contributes to iatrogenic anemia, decreased patient satisfaction, and increased health care costs. We employed a clinical decision support tool (CDST) to block unnecessary duplicate test orders during the computerized physician order entry (CPOE) process. We assessed laboratory cost savings after 2 years and searched for untoward patient events associated with this intervention. This CDST blocked 11,790 unnecessary duplicate test orders in these 2 years, which resulted in a cost savings of $183,586. There were no untoward effects reported associated with this intervention. The movement to CPOE affords real-time interaction between the laboratory and the physician through CDSTs that signal duplicate orders. These interactions save health care dollars and should also increase patient satisfaction and well-being.

  15. Impact of Laboratory Test Use Strategies in a Turkish Hospital

    PubMed Central

    Yılmaz, Fatma Meriç; Kahveci, Rabia; Aksoy, Altan; Özer Kucuk, Emine; Akın, Tezcan; Mathew, Joseph Lazar; Meads, Catherine; Zengin, Nurullah

    2016-01-01

    Objectives Eliminating unnecessary laboratory tests is a good way to reduce costs while maintain patient safety. The aim of this study was to define and process strategies to rationalize laboratory use in Ankara Numune Training and Research Hospital (ANH) and calculate potential savings in costs. Methods A collaborative plan was defined by hospital managers; joint meetings with ANHTA and laboratory professors were set; the joint committee invited relevant staff for input, and a laboratory efficiency committee was created. Literature was reviewed systematically to identify strategies used to improve laboratory efficiency. Strategies that would be applicable in local settings were identified for implementation, processed, and the impact on clinical use and costs assessed for 12 months. Results Laboratory use in ANH differed enormously among clinics. Major use was identified in internal medicine. The mean number of tests per patient was 15.8. Unnecessary testing for chloride, folic acid, free prostate specific antigen, hepatitis and HIV testing were observed. Test panel use was pinpointed as the main cause of overuse of the laboratory and the Hospital Information System test ordering page was reorganized. A significant decrease (between 12.6–85.0%) was observed for the tests that were taken to an alternative page on the computer screen. The one year study saving was equivalent to 371,183 US dollars. Conclusion Hospital-based committees including laboratory professionals and clinicians can define hospital based problems and led to a standardized approach to test use that can help clinicians reduce laboratory costs through appropriate use of laboratory tests. PMID:27077653

  16. Text Messaging Improves Participation in Laboratory Testing in Adolescent Liver Transplant Patients.

    PubMed

    McKenzie, Rebecca B; Berquist, William E; Foley, Megan A; Park, K T; Windsheimer, Jered E; Litt, Iris F

    In solid organ transplant patients, non-participation in all aspects of the medical regimen is a prevalent problem associated with adverse consequences particularly in the adolescent and young adult (AYA) age group. This study is the first to evaluate the feasibility, utility and impact of a text messaging (TM) intervention to improve participation in laboratory testing in adolescent liver transplant patients. AYA patients, aged 12 to 21 years, were recruited for a prospective pilot trial evaluating a TM intervention delivered over a 1-year period. The intervention involved automated TM reminders with feedback administered according to a prescribed laboratory testing frequency. Participation rate in laboratory testing after the intervention was compared to the year prior. Patient responses and feedback by text and survey were used to assess feasibility, acceptability and use of the intervention. Forty-two patients were recruited and 33 patients remained enrolled for the study duration. Recipients of the TM intervention demonstrated a significant improvement in participation rate in laboratory testing from 58% to 78% (P<.001). This rate was also significantly higher than in non-intervention controls (P=.003). There was a high acceptability, response rate and a significant correlation with reported versus actual completion of laboratory tests by TM. TM reminders significantly improved participation in laboratory testing in AYA liver transplant patients. The intervention demonstrated feasibility, acceptability, and use with a high proportion of patients who engaged in and perceived a benefit from using this technology.

  17. Developing a cardiopulmonary exercise testing laboratory.

    PubMed

    Diamond, Edward

    2007-12-01

    Cardiopulmonary exercise testing is a noninvasive and cost-effective technique that adds significant value to the assessment and management of a variety of symptoms and diseases. The penetration of this testing in medical practice may be limited by perceived operational and financial barriers. This article reviews coding and supervision requirements related to both simple and complex pulmonary stress testing. A program evaluation and review technique diagram is used to describe the work flow process. Data from our laboratory are used to generate an income statement that separates fixed and variable costs and calculates the contribution margin. A cost-volume-profit (break-even) analysis is then performed. Using data from our laboratory including fixed and variable costs, payer mix, reimbursements by payer, and the assumption that the studies are divided evenly between simple and complex pulmonary stress tests, the break-even number is calculated to be 300 tests per year. A calculator with embedded formulas has been designed by the author and is available on request. Developing a cardiopulmonary exercise laboratory is challenging but achievable and potentially profitable. It should be considered by a practice that seeks to distinguish itself as a quality leader. Providing this clinically valuable service may yield indirect benefits such as increased patient volume and increased utilization of other services provided by the practice. The decision for a medical practice to commit resources to managerial accounting support requires a cost-benefit analysis, but may be a worthwhile investment in our challenging economic environment.

  18. Analytical performances of food microbiology laboratories - critical analysis of 7 years of proficiency testing results.

    PubMed

    Abdel Massih, M; Planchon, V; Polet, M; Dierick, K; Mahillon, J

    2016-02-01

    Based on the results of 19 food microbiology proficiency testing (PT) schemes, this study aimed to assess the laboratory performances, to highlight the main sources of unsatisfactory analytical results and to suggest areas of improvement. The 2009-2015 results of REQUASUD and IPH PT, involving a total of 48 laboratories, were analysed. On average, the laboratories failed to detect or enumerate foodborne pathogens in 3·0% of the tests. Thanks to a close collaboration with the PT participants, the causes of outliers could be identified in 74% of the cases. The main causes of erroneous PT results were either pre-analytical (handling of the samples, timing of analysis), analytical (unsuitable methods, confusion of samples, errors in colony counting or confirmation) or postanalytical mistakes (calculation and encoding of results). PT schemes are a privileged observation post to highlight analytical problems, which would otherwise remain unnoticed. In this perspective, this comprehensive study of PT results provides insight into the sources of systematic errors encountered during the analyses. This study draws the attention of the laboratories to the main causes of analytical errors and suggests practical solutions to avoid them, in an educational purpose. The observations support the hypothesis that regular participation to PT, when followed by feed-back and appropriate corrective actions, can play a key role in quality improvement and provide more confidence in the laboratory testing results. © 2015 The Society for Applied Microbiology.

  19. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    PubMed

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  20. 3. VIEW LOOKING NORTH, COMPONENTS TEST LABORATORY, DYNAMIC TEST FACILITY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. VIEW LOOKING NORTH, COMPONENTS TEST LABORATORY, DYNAMIC TEST FACILITY (SATURN V IN BACKGROUND). - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL

  1. Closing the brain-to-brain loop in laboratory testing.

    PubMed

    Plebani, Mario; Lippi, Giuseppe

    2011-07-01

    Abstract The delivery of laboratory services has been described 40 years ago and defined with the foremost concept of "brain-to-brain turnaround time loop". This concept consists of several processes, including the final step which is the action undertaken on the patient based on laboratory information. Unfortunately, the need for systematic feedback to improve the value of laboratory services has been poorly understood and, even more risky, poorly applied in daily laboratory practice. Currently, major problems arise from the unavailability of consensually accepted quality specifications for the extra-analytical phase of laboratory testing. This, in turn, does not allow clinical laboratories to calculate a budget for the "patient-related total error". The definition and use of the term "total error" refers only to the analytical phase, and should be better defined as "total analytical error" to avoid any confusion and misinterpretation. According to the hierarchical approach to classify strategies to set analytical quality specifications, the "assessment of the effect of analytical performance on specific clinical decision-making" is comprehensively at the top and therefore should be applied as much as possible to address analytical efforts towards effective goals. In addition, an increasing number of laboratories worldwide are adopting risk management strategies such as FMEA, FRACAS, LEAN and Six Sigma since these techniques allow the identification of the most critical steps in the total testing process, and to reduce the patient-related risk of error. As a matter of fact, an increasing number of laboratory professionals recognize the importance of understanding and monitoring any step in the total testing process, including the appropriateness of the test request as well as the appropriate interpretation and utilization of test results.

  2. Serving the Nation for Fifty Years: 1952 - 2002 Lawrence Livermore National Laboratory [LLNL], Fifty Years of Accomplishments

    DOE R&D Accomplishments Database

    2002-01-01

    For 50 years, Lawrence Livermore National Laboratory has been making history and making a difference. The outstanding efforts by a dedicated work force have led to many remarkable accomplishments. Creative individuals and interdisciplinary teams at the Laboratory have sought breakthrough advances to strengthen national security and to help meet other enduring national needs. The Laboratory's rich history includes many interwoven stories -- from the first nuclear test failure to accomplishments meeting today's challenges. Many stories are tied to Livermore's national security mission, which has evolved to include ensuring the safety, security, and reliability of the nation's nuclear weapons without conducting nuclear tests and preventing the proliferation and use of weapons of mass destruction. Throughout its history and in its wide range of research activities, Livermore has achieved breakthroughs in applied and basic science, remarkable feats of engineering, and extraordinary advances in experimental and computational capabilities. From the many stories to tell, one has been selected for each year of the Laboratory's history. Together, these stories give a sense of the Laboratory -- its lasting focus on important missions, dedication to scientific and technical excellence, and drive to made the world more secure and a better place to live.

  3. The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system.

    PubMed

    Massambu, Charles; Mwangi, Christina

    2009-06-01

    The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.

  4. Quality assurance of laboratory work and clinical use of laboratory tests in general practice in norway: a survey.

    PubMed

    Thue, Geir; Jevnaker, Marianne; Gulstad, Guri Andersen; Sandberg, Sverre

    2011-09-01

    Virtually all the general practices in Norway participate in the Norwegian Quality Improvement of Laboratory Services in Primary Care, NOKLUS. In order to assess and develop NOKLUS's services, it was decided to carry out an investigation in the largest participating group, general practices. In autumn 2008 a questionnaire was sent to all Norwegian general practices asking for feedback on different aspects of NOKLUS's main services: contact with medical laboratory technologists, sending of control materials, use and maintenance of practice-specific laboratory binders, courses, and testing of laboratory equipment. In addition, attitudes were elicited towards possible new services directed at assessing other technical equipment and clinical use of tests. Responses were received from 1290 of 1552 practices (83%). The great majority thought that the frequency of sending out control material should continue as at present, and they were pleased with the feedback reports and follow-up by the laboratory technologists in the counties. Even after many years of practical experience, there is still a need to update laboratory knowledge through visits to practices, courses, and written information. Practices also wanted quality assurance of blood pressure meters and spirometers, and many doctors wanted feedback on their use of laboratory tests. Services regarding quality assurance of point-of-care tests, guidance, and courses should be continued. Quality assurance of other technical equipment and of the doctor's clinical use of laboratory tests should be established as part of comprehensive quality assurance.

  5. Evaluation of analytical errors in a clinical chemistry laboratory: a 3 year experience.

    PubMed

    Sakyi, As; Laing, Ef; Ephraim, Rk; Asibey, Of; Sadique, Ok

    2015-01-01

    Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified.

  6. Error identification in a high-volume clinical chemistry laboratory: Five-year experience.

    PubMed

    Jafri, Lena; Khan, Aysha Habib; Ghani, Farooq; Shakeel, Shahid; Raheem, Ahmed; Siddiqui, Imran

    2015-07-01

    Quality indicators for assessing the performance of a laboratory require a systematic and continuous approach in collecting and analyzing data. The aim of this study was to determine the frequency of errors utilizing the quality indicators in a clinical chemistry laboratory and to convert errors to the Sigma scale. Five-year quality indicator data of a clinical chemistry laboratory was evaluated to describe the frequency of errors. An 'error' was defined as a defect during the entire testing process from the time requisition was raised and phlebotomy was done until the result dispatch. An indicator with a Sigma value of 4 was considered good but a process for which the Sigma value was 5 (i.e. 99.977% error-free) was considered well controlled. In the five-year period, a total of 6,792,020 specimens were received in the laboratory. Among a total of 17,631,834 analyses, 15.5% were from within hospital. Total error rate was 0.45% and of all the quality indicators used in this study the average Sigma level was 5.2. Three indicators - visible hemolysis, failure of proficiency testing and delay in stat tests - were below 5 on the Sigma scale and highlight the need to rigorously monitor these processes. Using Six Sigma metrics quality in a clinical laboratory can be monitored more effectively and it can set benchmarks for improving efficiency.

  7. Some new tests at the Gottingen laboratory

    NASA Technical Reports Server (NTRS)

    1921-01-01

    The tests at the Gottingen laboratory included: friction tests on a surface treated with omelette, verification tests on the M.V.A. 356 wing, and comparative tests of wing no. 36 at the Eiffel laboratory. The examination of all these experiments leads to the belief that, at large incidences, the speeds registered by the suction manometer of the testing chamber of the Eiffel laboratory wind tunnel are, owing to pressure drop, greater than the actual speeds. Therefore, the values of k(sub x) and k(sub y) measured at the Eiffel laboratory at large incidences are too low.

  8. Impact of add-on laboratory testing at an academic medical center: a five year retrospective study.

    PubMed

    Nelson, Louis S; Davis, Scott R; Humble, Robert M; Kulhavy, Jeff; Aman, Dean R; Krasowski, Matthew D

    2015-01-01

    Clinical laboratories frequently receive orders to perform additional tests on existing specimens ('add-ons'). Previous studies have examined add-on ordering patterns over short periods of time. The objective of this study was to analyze add-on ordering patterns over an extended time period. We also analyzed the impact of a robotic specimen archival/retrieval system on add-on testing procedure and manual effort. In this retrospective study at an academic medical center, electronic health records from were searched to obtain all add-on orders that were placed in the time period of May 2, 2009 to December 31, 2014. During the time period of retrospective study, 880,359 add-on tests were ordered on 96,244 different patients. Add-on testing comprised 3.3 % of total test volumes. There were 443,411 unique ordering instances, leading to an average of 1.99 add-on tests per instance. Some patients had multiple episodes of add-on test orders at different points in time, leading to an average of 9.15 add-on tests per patient. The majority of add-on orders were for chemistry tests (78.8 % of total add-ons) with the next most frequent being hematology and coagulation tests (11.2 % of total add-ons). Inpatient orders accounted for 66.8 % of total add-on orders, while the emergency department and outpatient clinics had 14.8 % and 18.4 % of total add-on orders, respectively. The majority of add-ons were placed within 8 hours (87.3 %) and nearly all by 24 hours (96.8 %). Nearly 100 % of add-on orders within the emergency department were placed within 8 hours. The introduction of a robotic specimen archival/retrieval unit saved an average of 2.75 minutes of laboratory staff manual time per unique add-on order. This translates to 24.1 hours/day less manual effort in dealing with add-on orders. Our study reflects the previous literature in showing that add-on orders significantly impact the workload of the clinical laboratory. The majority of add-on orders are clinical chemistry

  9. Syphilis testing in antenatal care: Policies and practices among laboratories in the Americas.

    PubMed

    Luu, Minh; Ham, Cal; Kamb, Mary L; Caffe, Sonja; Hoover, Karen W; Perez, Freddy

    2015-06-01

    To asses laboratory syphilis testing policies and practices among laboratories in the Americas. Laboratory directors or designees from PAHO member countries were invited to participate in a structured, electronically-delivered survey between March and August, 2014. Data on syphilis tests, algorithms, and quality control (QC) practices were analyzed, focusing on laboratories receiving specimens from antenatal clinics (ANCs). Surveys were completed by 69 laboratories representing 30 (86%) countries. Participating laboratories included 36 (52%) national or regional reference labs and 33 (48%) lower-level laboratories. Most (94%) were public sector facilities and 71% reported existence of a national algorithm for syphilis testing in pregnancy, usually involving both treponemal and non-treponemal testing (72%). Less than half (41%) used rapid syphilis tests (RSTs); and only seven laboratories representing five countries reported RSTs were included in the national algorithm for pregnant women. Most (83%) laboratories serving ANCs reported using some type of QC system; 68% of laboratories reported participation in external QC. Only 36% of laboratories reported data to national/local surveillance. Half of all laboratories serving ANC settings reported a stockout of one or more essential supplies during the previous year (median duration, 30days). Updating laboratory algorithms, improving testing standards, integrating data into existing surveillance, and improved procurement and distribution of commodities may be needed to ensure elimination of MTCT of syphilis in the Americas. Copyright © 2015. Published by Elsevier Ireland Ltd.

  10. Misleading biochemical laboratory test results

    PubMed Central

    Nanji, Amin A.

    1984-01-01

    This article reviews the general and specific factors that interfere with the performance of common biochemical laboratory tests and the interpretation of their results. The clinical status of the patient, drug interactions, and in-vivo and in-vitro biochemical interactions and changes may alter the results obtained from biochemical analysis of blood constituents. Failure to recognize invalid laboratory test results may lead to injudicious and dangerous management of patients. PMID:6375845

  11. Evaluation of Analytical Errors in a Clinical Chemistry Laboratory: A 3 Year Experience

    PubMed Central

    Sakyi, AS; Laing, EF; Ephraim, RK; Asibey, OF; Sadique, OK

    2015-01-01

    Background: Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. Aim: We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. Materials and Methods: We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). Results: A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Conclusion: Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified. PMID:25745569

  12. Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008-2010.

    PubMed

    Dimech, Wayne; Lim, Megan S C; Van Gemert, Caroline; Guy, Rebecca; Boyle, Douglas; Donovan, Basil; Hellard, Margaret

    2014-06-12

    Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data highlight much lower levels of testing in

  13. [How do hospital clinical laboratories and laboratory testing companies cooperate and build reciprocal relations?].

    PubMed

    Kawano, Seiji

    2014-12-01

    As the 2nd Joint Symposium of the Japanese Society of Laboratory Medicine and the Japanese Association of Laboratory Pathologists, the symposium on clinical test out-sourcing and branch laboratories was held at the 60th General Meeting of the Japanese Society of Laboratory Medicine on November 2nd, 2013 in Kobe. For the symposium, we conducted a questionnaire survey on the usage of clinical test out-sourcing and the introduction of branch laboratories to clinical laboratories of Japanese university hospitals, both private and public, between July 25th and August 20th, 2013. Seventy-two hospitals responded to the questionnaire survey, consisting of 41 public medical school hospitals and 31 private ones. According to the survey, the selection of each clinical test for out-sourcing was mainly determined by the capacities of hospital clinical laboratories and their equipment, as well as the profitability of each test. The main concerns of clinical laboratory members of university hospitals involved the continuity of measurement principles, traceability, and standardization of reference values for each test. They strongly requested the interchangeability and computerization of test data between laboratory testing companies. A branch laboratory was introduced to six hospitals, all of which were private medical college hospitals, out of 72 university hospitals, and eight of the other hospitals were open to its introduction. The merits and demerits of introducing a branch laboratory were also discussed. (Review).

  14. [Point-of-care-testing--the intensive care laboratory].

    PubMed

    Müller, M M; Hackl, W; Griesmacher, A

    1999-01-01

    After successful centralization of laboratory analyses since more than 30 years, advances in biosensors, microprocessors, measurement of undiluted whole blood and miniaturization of laboratory analyzers are leading nowadays more and more to a re-decentralization in the laboratory medicine. Point-of-care-testing (POCT), which is defined as any laboratory test performed outside central or decentralized laboratories, is becoming more and more popular. The theoretical advantages of POCT are faster turn-around-times (TAT), more rapid medical decisions, avoidance of sample identification and sample transport problems and the need of only small specimen volumes. These advantages are frequently mentioned, but are not associated with a clear clinical benefit. The disadvantages of POCT such as incorrect handling and/or maintenance of the analyzers by nontrained clinical staff, inadequate or even absent calibrations and/or quality controls, lack of cost-effectiveness because of an increased number of analyzers and more expensive reagents, insufficient documentation and difficult comparability of the obtained POCT-results with routine laboratory results, are strongly evident. According to the authors' opinion the decision for the establishing of POCT has only to be made in a close co-operation between physicians and laboratorians in order to vouch for necessity and high quality of the analyses. Taking the local situation into consideration (24-h-central laboratory, etc.) the spectrum of parameters measured by means of POCT should be rigorously restricted to the vital functions. Such analytes should be: hemoglobin or hematocrit, activated whole blood clotting time, blood gases, sodium, potassium, ionized calcium, glucose, creatinine, ammonia and lactate.

  15. Structural Test Laboratory | Water Power | NREL

    Science.gov Websites

    Structural Test Laboratory Structural Test Laboratory NREL engineers design and configure structural components can validate models, demonstrate system reliability, inform design margins, and assess , including mass and center of gravity, to ensure compliance with design goals Dynamic Characterization Use

  16. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  17. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  18. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  19. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  20. 49 CFR 199.107 - Drug testing laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Drug testing laboratory. 199.107 Section 199.107... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this...

  1. Fuel Cell Development and Test Laboratory | Energy Systems Integration

    Science.gov Websites

    Facility | NREL Fuel Cell Development and Test Laboratory Fuel Cell Development and Test Laboratory The Energy System Integration Facility's Fuel Cell Development and Test Laboratory supports fuel a fuel cell test in the Fuel Cell Development and Test Laboratory. Capability Hubs The Fuel Cell

  2. Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008–2010

    PubMed Central

    2014-01-01

    Background Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. Methods The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. Results From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). Conclusions The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data

  3. External quality assessment of medical laboratories in Croatia: preliminary evaluation of post-analytical laboratory testing.

    PubMed

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana

    2017-02-15

    Proper standardization of laboratory testing requires assessment of performance after the tests are performed, known as the post-analytical phase. A nationwide external quality assessment (EQA) scheme implemented in Croatia in 2014 includes a questionnaire on post-analytical practices, and the present study examined laboratory responses in order to identify current post-analytical phase practices and identify areas for improvement. In four EQA exercises between September 2014 and December 2015, 145-174 medical laboratories across Croatia were surveyed using the Module 11 questionnaire on the post-analytical phase of testing. Based on their responses, the laboratories were evaluated on four quality indicators: turnaround time (TAT), critical values, interpretative comments and procedures in the event of abnormal results. Results were presented as absolute numbers and percentages. Just over half of laboratories (56.3%) monitored TAT. Laboratories varied substantially in how they dealt with critical values. Most laboratories (65-97%) issued interpretative comments with test results. One third of medical laboratories (30.6-33.3%) issued abnormal test results without confirming them in additional testing. Our results suggest that the nationwide post-analytical EQA scheme launched in 2014 in Croatia has yet to be implemented to the full. To close the gaps between existing recommendations and laboratory practice, laboratory professionals should focus on ensuring that TAT is monitored and lists of critical values are established within laboratories. Professional bodies/institutions should focus on clarify and harmonized rules to standardized practices and applied for adding interpretative comments to laboratory test results and for dealing with abnormal test results.

  4. [Quality use of commercial laboratory for clinical testing services - considering laboratory's role].

    PubMed

    Ogawa, Shinji

    2014-12-01

    The number of commercial laboratories for clinical testing in Japan run privately has decreased to about 30 companies, and their business is getting tougher. Branch Lab. and FMS businesses have not expanded recently due to the new reimbursement system which adds an additional sample management fee, becoming effective in 2010. This presentation gives an outline of each role for hospital and commercial laboratories, and their pros & cons considering the current medical situation. Commercial laboratories have investigated how to utilize ICT systems for sharing test information between hospitals and our facilities. It would be very helpful to clarify issues for each hospital. We will develop and create new values for clinical laboratory testing services and forge mutually beneficial relationships with medical institutions. (Review).

  5. 19 CFR 151.54 - Testing by Customs laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Testing by Customs laboratory. 151.54 Section 151... Other Metal-Bearing Materials § 151.54 Testing by Customs laboratory. Samples taken in accordance with § 151.52 shall be promptly forwarded to the appropriate Customs laboratory for testing in accordance...

  6. How Reliable Is Laboratory Testing?

    MedlinePlus

    ... laboratory testing. (See Who's Who in the Lab .) Post-Analytic Activities After the test is completed, the result must be delivered in ... View Sources NOTE: This article is based on research that ... of the Lab Tests Online Editorial Review Board . This article is periodically ...

  7. Point-Counterpoint: The FDA Has a Role in Regulation of Laboratory-Developed Tests.

    PubMed

    Caliendo, Angela M; Hanson, Kimberly E

    2016-04-01

    Since the Food and Drug Administration (FDA) released its draft guidance on the regulation of laboratory-developed tests (LDTs) in October 2014, there has been a flurry of responses from commercial and hospital-based laboratory directors, clinicians, professional organizations, and diagnostic companies. The FDA defines an LDT as an "in vitrodiagnostic device that is intended for clinical use and is designed, manufactured, and used within a single laboratory." The draft guidance outlines a risk-based approach, with oversight of high-risk and moderate-risk tests being phased in over 9 years. High-risk tests would be regulated first and require premarket approval. Subsequently, moderate-risk tests would require a 510(k) premarket submission to the FDA and low-risk tests would need only to be registered. Oversight discretion would be exercised for LDTs focused on rare diseases (defined as fewer than 4,000 tests, not cases, per year nationally) and unmet clinical needs (defined as those tests for which there is no alternative FDA-cleared or -approved test). There was an open comment period followed by a public hearing in early January of 2015, and we are currently awaiting the final decision regarding the regulation of LDTs. Given that LDTs have been developed by many laboratories and are essential for the diagnosis and monitoring of an array of infectious diseases, changes in their regulation will have far-reaching implications for clinical microbiology laboratories. In this Point-Counterpoint, Angela Caliendo discusses the potential benefits of the FDA guidance for LDTs whereas Kim Hanson discusses the concerns associated with implementing the guidance and why these regulations may not improve clinical care. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  8. Mars Science Laboratory Spacecraft Assembled for Testing

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The major components of NASA's Mars Science Laboratory spacecraft cruise stage atop the aeroshell, which has the descent stage and rover inside were connected together in October 2008 for several weeks of system testing, including simulation of launch vibrations and deep-space environmental conditions.

    These components will be taken apart again, for further work on each of them, after the environmental testing. The Mars Science Laboratory spacecraft is being assembled and tested for launch in 2011.

    This image was taken inside the Spacecraft Assembly Facility at NASA's Jet Propulsion Laboratory, Pasadena, Calif., which manages the Mars Science Laboratory Project for the NASA Science Mission Directorate, Washington. JPL is a division of the California Institute of Technology.

  9. Grid Modernization Laboratory Consortium - Testing and Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroposki, Benjamin; Skare, Paul; Pratt, Rob

    This paper highlights some of the unique testing capabilities and projects being performed at several national laboratories as part of the U. S. Department of Energy Grid Modernization Laboratory Consortium. As part of this effort, the Grid Modernization Laboratory Consortium Testing Network isbeing developed to accelerate grid modernization by enablingaccess to a comprehensive testing infrastructure and creating a repository of validated models and simulation tools that will be publicly available. This work is key to accelerating thedevelopment, validation, standardization, adoption, and deployment of new grid technologies to help meet U. S. energy goals.

  10. Association of Reference Pricing for Diagnostic Laboratory Testing With Changes in Patient Choices, Prices, and Total Spending for Diagnostic Tests.

    PubMed

    Robinson, James C; Whaley, Christopher; Brown, Timothy T

    2016-09-01

    Prices for laboratory and other clinical services vary widely. Employers and insurers increasingly are adopting "reference pricing" policies to create incentives for patients to select lower-priced facilities. To measure the association between implementation of reference pricing and patient choice of laboratory, test prices, patient out-of-pocket spending, and insurer spending. We conducted an observational study of changes in laboratory pricing and selection by employees of a large national grocery firm (n = 30 415) before and after the firm implemented a reference pricing policy for laboratory services and compared the findings with changes over the same period for policy holders of a large national insurer that did not implement reference pricing (n = 181 831). The grocery firm established a maximum payment limit at the 60th percentile of the distribution of prices for each laboratory test in each region. Employees were provided with data on prices at all laboratories through a mobile digital platform. Patients selecting a laboratory that charged more than the payment limit were required to pay the full difference themselves. A total of 2.13 million claims were analyzed for 285 types of in vitro diagnostic tests between 2010 and 2013. Patient choice of laboratory, price paid per test, patient out-of-pocket costs, and employer spending. Compared with trends in prices paid by insurance policy holders not subject to reference pricing, and after adjusting for characteristics of tests and patients, implementation of reference pricing was associated with a 31.9% reduction (95% CI, 20.6%-41.6%) in average price paid per test by the third year of the program. In these 3 years, total spending on laboratory tests declined by $2.57 million (95% CI, $1.59-$3.35 million). Out-of-pocket costs by patients declined by $1.05 million (95% CI, $0.73-$1.37 million). Spending by the employer declined by $1.70 million (95% CI, $0.92-$2.48 million). When combined with

  11. Changing resident test ordering behavior: a multilevel intervention to decrease laboratory utilization at an academic medical center.

    PubMed

    Vidyarthi, Arpana R; Hamill, Timothy; Green, Adrienne L; Rosenbluth, Glenn; Baron, Robert B

    2015-01-01

    Hospital laboratory test volume is increasing, and overutilization contributes to errors and costs. Efforts to reduce laboratory utilization have targeted aspects of ordering behavior, but few have utilized a multilevel collaborative approach. The study team partnered with residents to reduce unnecessary laboratory tests and associated costs through multilevel interventions across the academic medical center. The study team selected laboratory tests for intervention based on cost, volume, and ordering frequency (complete blood count [CBC] and CBC with differential, common electrolytes, blood enzymes, and liver function tests). Interventions were designed collaboratively with residents and targeted components of ordering behavior, including system changes, teaching, social marketing, academic detailing, financial incentives, and audit/feedback. Laboratory ordering was reduced by 8% cumulatively over 3 years, saving $2 019 000. By involving residents at every stage of the intervention and targeting multiple levels simultaneously, laboratory utilization was reduced and cost savings were sustained over 3 years. © 2014 by the American College of Medical Quality.

  12. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1993-03-01

    Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.

  13. Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory

    NASA Astrophysics Data System (ADS)

    Aubert, Cédric; Osmond, Mélanie

    2008-08-01

    For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it [1]. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as "Interlaboratory Comparisons" for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance. Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements

  14. Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aubert, Cedric; Osmond, Melanie

    2008-08-14

    For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratorymore » Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements

  15. Evaluation of Mycology Laboratory Proficiency Testing

    PubMed Central

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601

  16. 42 CFR 493.1441 - Condition: Laboratories performing high complexity testing; laboratory director.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; laboratory director. 493.1441 Section 493.1441 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  17. 42 CFR 493.1441 - Condition: Laboratories performing high complexity testing; laboratory director.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; laboratory director. 493.1441 Section 493.1441 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  18. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    PubMed

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  19. Energy Systems High-Pressure Test Laboratory | Energy Systems Integration

    Science.gov Websites

    Facility | NREL Energy Systems High-Pressure Test Laboratory Energy Systems High-Pressure Test Laboratory In the Energy Systems Integration Facility's High-Pressure Test Laboratory, researchers can safely test high-pressure hydrogen components. Photo of researchers running an experiment with a hydrogen fuel

  20. Testing activities at the National Battery Test Laboratory

    NASA Astrophysics Data System (ADS)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  1. College of American Pathologists' laboratory standards for next-generation sequencing clinical tests.

    PubMed

    Aziz, Nazneen; Zhao, Qin; Bry, Lynn; Driscoll, Denise K; Funke, Birgit; Gibson, Jane S; Grody, Wayne W; Hegde, Madhuri R; Hoeltge, Gerald A; Leonard, Debra G B; Merker, Jason D; Nagarajan, Rakesh; Palicki, Linda A; Robetorye, Ryan S; Schrijver, Iris; Weck, Karen E; Voelkerding, Karl V

    2015-04-01

    The higher throughput and lower per-base cost of next-generation sequencing (NGS) as compared to Sanger sequencing has led to its rapid adoption in clinical testing. The number of laboratories offering NGS-based tests has also grown considerably in the past few years, despite the fact that specific Clinical Laboratory Improvement Amendments of 1988/College of American Pathologists (CAP) laboratory standards had not yet been developed to regulate this technology. To develop a checklist for clinical testing using NGS technology that sets standards for the analytic wet bench process and for bioinformatics or "dry bench" analyses. As NGS-based clinical tests are new to diagnostic testing and are of much greater complexity than traditional Sanger sequencing-based tests, there is an urgent need to develop new regulatory standards for laboratories offering these tests. To develop the necessary regulatory framework for NGS and to facilitate appropriate adoption of this technology for clinical testing, CAP formed a committee in 2011, the NGS Work Group, to deliberate upon the contents to be included in the checklist. Results . -A total of 18 laboratory accreditation checklist requirements for the analytic wet bench process and bioinformatics analysis processes have been included within CAP's molecular pathology checklist (MOL). This report describes the important issues considered by the CAP committee during the development of the new checklist requirements, which address documentation, validation, quality assurance, confirmatory testing, exception logs, monitoring of upgrades, variant interpretation and reporting, incidental findings, data storage, version traceability, and data transfer confidentiality.

  2. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2013-10-01 2013-10-01 false What drugs do laboratories test for? 40.85 Section...

  3. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2014-10-01 2014-10-01 false What drugs do laboratories test for? 40.85 Section...

  4. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2011-10-01 2011-10-01 false What drugs do laboratories test for? 40.85 Section...

  5. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2012-10-01 2012-10-01 false What drugs do laboratories test for? 40.85 Section...

  6. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2010-10-01 2010-10-01 false What drugs do laboratories test for? 40.85 Section...

  7. 10 CFR 431.18 - Testing laboratories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... EQUIPMENT Electric Motors Test Procedures, Materials Incorporated and Methods of Determining Efficiency... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory... of the National Institute of Standards and Technology (NIST) which is part of the U.S. Department of...

  8. Laboratory testing under managed care dominance in the USA

    PubMed Central

    Takemura, Y; Beck, J

    2001-01-01

    The uncontrolled escalation of total health care expenditure despite the government's endeavours during the past decades in the USA had led to the rapid infiltration of managed care organisations (MCOs). Traditional hospital based laboratories have been placed in a crucial situation with the advent of the managed care era. A massive reduction of in house testing urged them to develop strategies against financial difficulty. Consolidation and networking, participation in the outreach testing market, and emphasis on point of care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for the survival of hospital laboratories. Several physicians' office laboratories (POLS) have closed their doors in response both to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988 and to managed care infiltration. It seems likely that POLs and hospital laboratories will continue to reduce test volumes, whereas commercial reference laboratories will thrive through contracting with MCOs. In the current climate of managed care dominance in the USA, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Key Words: laboratory testing • managed care organisations • survival strategies PMID:11215291

  9. Laboratory Diagnostics Market in East Africa: A Survey of Test Types, Test Availability, and Test Prices in Kampala, Uganda.

    PubMed

    Schroeder, Lee F; Elbireer, Ali; Jackson, J Brooks; Amukele, Timothy K

    2015-01-01

    Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda. Test types (identity) and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI). AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015. Test volumes and menus were obtained for 95% (907/954) of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests), moderate (33 tests), and minimal (55 tests) availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46). One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.

  10. 7 CFR 75.43 - Laboratory testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory testing. 75.43 Section 75.43 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... AND CERTIFICATION OF QUALITY OF AGRICULTURAL AND VEGETABLE SEEDS Fees and Charges § 75.43 Laboratory...

  11. 7 CFR 75.43 - Laboratory testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory testing. 75.43 Section 75.43 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... AND CERTIFICATION OF QUALITY OF AGRICULTURAL AND VEGETABLE SEEDS Fees and Charges § 75.43 Laboratory...

  12. LabRS: A Rosetta stone for retrospective standardization of clinical laboratory test results.

    PubMed

    Hauser, Ronald George; Quine, Douglas B; Ryder, Alex

    2018-02-01

    Clinical laboratories in the United States do not have an explicit result standard to report the 7 billion laboratory tests results they produce each year. The absence of standardized test results creates inefficiencies and ambiguities for secondary data users. We developed and tested a tool to standardize the results of laboratory tests in a large, multicenter clinical data warehouse. Laboratory records, each of which consisted of a laboratory result and a test identifier, from 27 diverse facilities were captured from 2000 through 2015. Each record underwent a standardization process to convert the original result into a format amenable to secondary data analysis. The standardization process included the correction of typos, normalization of categorical results, separation of inequalities from numbers, and conversion of numbers represented by words (eg, "million") to numerals. Quality control included expert review. We obtained 1.266 × 109 laboratory records and standardized 1.252 × 109 records (98.9%). Of the unique unstandardized records (78.887 × 103), most appeared <5 times (96%, eg, typos), did not have a test identifier (47%), or belonged to an esoteric test with <100 results (2%). Overall, these 3 reasons accounted for nearly all unstandardized results (98%). Current results suggest that the tool is both scalable and generalizable among diverse clinical laboratories. Based on observed trends, the tool will require ongoing maintenance to stay current with new tests and result formats. Future work to develop and implement an explicit standard for test results would reduce the need to retrospectively standardize test results. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  13. Crush Testing at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, Matthew R

    2011-01-01

    The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type packagemore » designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.« less

  14. 40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What transient duty cycles apply for... Procedures § 1048.510 What transient duty cycles apply for laboratory testing? (a) Starting with the 2007 model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in...

  15. Space Electric Research Test in the Electric Propulsion Laboratory

    NASA Image and Video Library

    1964-06-21

    Technicians prepare the Space Electric Research Test (SERT-I) payload for a test in Tank Number 5 of the Electric Propulsion Laboratory at the National Aeronautics and Space Administration (NASA) Lewis Research Center. Lewis researchers had been studying different methods of electric rocket propulsion since the mid-1950s. Harold Kaufman created the first successful engine, the electron bombardment ion engine, in the early 1960s. These electric engines created and accelerated small particles of propellant material to high exhaust velocities. Electric engines have a very small amount of thrust, but once lofted into orbit by workhorse chemical rockets, they are capable of small, continuous thrust for periods up to several years. The electron bombardment thruster operated at a 90-percent efficiency during testing in the Electric Propulsion Laboratory. The package was rapidly rotated in a vacuum to simulate its behavior in space. The SERT-I mission, launched from Wallops Island, Virginia, was the first flight test of Kaufman’s ion engine. SERT-I had one cesium engine and one mercury engine. The suborbital flight was only 50 minutes in duration but proved that the ion engine could operate in space. The Electric Propulsion Laboratory included two large space simulation chambers, one of which is seen here. Each uses twenty 2.6-foot diameter diffusion pumps, blowers, and roughing pumps to remove the air inside the tank to create the thin atmosphere. A helium refrigeration system simulates the cold temperatures of space.

  16. Managing laboratory test ordering through test frequency filtering.

    PubMed

    Janssens, Pim M W; Wasser, Gerd

    2013-06-01

    Modern computer systems allow limits to be set on the periods allowed for repetitive testing. We investigated a computerised system for managing potentially overtly frequent laboratory testing, calculating the financial savings obtained. In consultation with hospital physicians, tests were selected for which 'spare periods' (periods during which tests are barred) might be set to control repetitive testing. The tests were selected and spare periods determined based on known analyte variations in health and disease, variety of tissues or cells giving rise to analytes, clinical conditions and rate of change determining analyte levels, frequency with which doctors need information about the analytes and the logistical needs of the clinic. The operation and acceptance of the system was explored with 23 analytes. Frequency filtering was subsequently introduced for 44 tests, each with their own spare periods. The proportion of tests barred was 0.56%, the most frequent of these being for total cholesterol, uric acid and HDL-cholesterol. The financial savings were 0.33% of the costs of all testing, with HbA1c, HDL-cholesterol and vitamin B12 yielding the largest savings. Following the introduction of the system the number of barred tests ultimately decreased, suggesting accommodation by the test requestors. Managing laboratory testing through computerised limits to prevent overtly frequent testing is feasible. The savings were relatively low, but sustaining the system takes little effort, giving little reason not to apply it. The findings will serve as a basis for improving the system and may guide others in introducing similar systems.

  17. Testing a Constrained MPC Controller in a Process Control Laboratory

    ERIC Educational Resources Information Center

    Ricardez-Sandoval, Luis A.; Blankespoor, Wesley; Budman, Hector M.

    2010-01-01

    This paper describes an experiment performed by the fourth year chemical engineering students in the process control laboratory at the University of Waterloo. The objective of this experiment is to test the capabilities of a constrained Model Predictive Controller (MPC) to control the operation of a Double Pipe Heat Exchanger (DPHE) in real time.…

  18. Clinical Laboratory Sciences: The Next Twenty Years.

    ERIC Educational Resources Information Center

    Morris, Frances J.

    The views of professionals concerning the future of the clinical laboratory sciences were assessed using a modification of the Delphi technique. The participating administrators, educators, and bench technologists were asked what they felt the clinical laboratory sciences would be like in 20 years, and their responses were used to develop…

  19. [Unnecessary routine laboratory tests in patients referred for surgical services].

    PubMed

    Mata-Miranda, María del Pilar; Cano-Matus, Norberto; Rodriguez-Murrieta, Margarita; Guarneros-Zapata, Idalia; Ortiz, Mario

    2016-01-01

    To question the usefulness of the lab analysis considered routine testing for the identification of abnormalities in the surgical care. To determine the percentage of unnecessary laboratory tests in the preoperative assessment as well as to estimate the unnecessary expenses. A descriptive, cross-sectional study of patients referred for surgical evaluation between January 1st and March 31st 2013. The database of laboratory testing and electronic files were reviewed. Reference criteria from surgical services were compared with the tests requested by the family doctor. In 65% of the patients (n=175) unnecessary examinations were requested, 25% (n=68) were not requested the tests that they required, and only 10% of the patients were requested laboratory tests in accordance with the reference criteria (n=27). The estimated cost in unnecessary examinations was $1,129,552 in a year. The results were similar to others related to this theme, however, they had not been revised from the perspective of the first level of attention regarding the importance of adherence to the reference criteria which could prevent major expenditures. It is a priority for leaders and operational consultants in medical units to establish strategies and lines of action that ensure compliance with institutional policies so as to contain spending on comprehensive services, and which in turn can improve the medical care. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  20. 42 CFR 493.1487 - Condition: Laboratories performing high complexity testing; testing personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; testing personnel. 493.1487 Section 493.1487 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  1. 42 CFR 493.1487 - Condition: Laboratories performing high complexity testing; testing personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; testing personnel. 493.1487 Section 493.1487 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  2. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis & Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during FY-92 on both single cells and multi-cell modules that encompass six battery technologies (Na/S, Li/FeS, Ni/Metal-Hydride, Ni/Zn, Ni/Cd, Ni/Fe). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  3. Total laboratory automation: Do stat tests still matter?

    PubMed

    Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro

    2017-07-01

    During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  4. State 'laboratories' test health care reform solutions.

    PubMed

    Elliott, B A

    1993-02-01

    Widely recognized by the states as a pressing policy issue, health care reform appears to have moved up on the national policy agenda as well. President Clinton has promised to address the issue during his first 100 days in office. Previously, however, the federal government has been deadlocked on health care reform, leaving the states to become the laboratories for developing and testing proposed solutions to our health care crisis. By passing MinnesotaCare in last year's legislative session, Minnesota joined the growing number of states attempting to provide access to affordable, quality health care to their citizens.

  5. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  6. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  7. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  8. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  9. 21 CFR 640.67 - Laboratory tests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit of Source Plasma shall be tested for evidence of infection due to communicable disease agents as required...

  10. Laboratory testing of two prototype in-vehicle breath test devices

    DOT National Transportation Integrated Search

    1985-08-01

    This report presents the results of laboratory testing of two recently developed prototype in-vehicle breath test devices. These devices are designed to prevent persons with alcohol on their breath from driving a car. The devices tested were the SOBE...

  11. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    PubMed

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  12. Characterization of Orbital Debris via Hyper-Velocity Laboratory-Based Tests

    NASA Technical Reports Server (NTRS)

    Cowardin, Heather; Liou, J.-C.; Anz-Meador, Phillip; Sorge, Marlon; Opiela, John; Fitz-Coy, Norman; Huynh, Tom; Krisko, Paula

    2017-01-01

    Existing DOD and NASA satellite breakup models are based on a key laboratory test, Satellite Orbital debris Characterization Impact Test (SOCIT), which has supported many applications and matched on-orbit events involving older satellite designs reasonably well over the years. In order to update and improve these models, the NASA Orbital Debris Program Office, in collaboration with the Air Force Space and Missile Systems Center, The Aerospace Corporation, and the University of Florida, replicated a hypervelocity impact using a mock-up satellite, DebriSat, in controlled laboratory conditions. DebriSat is representative of present-day LEO satellites, built with modern spacecraft materials and construction techniques. Fragments down to 2 mm in size will be characterized by their physical and derived properties. A subset of fragments will be further analyzed in laboratory radar and optical facilities to update the existing radar-based NASA Size Estimation Model (SEM) and develop a comparable optical-based SEM. A historical overview of the project, status of the characterization process, and plans for integrating the data into various models will be discussed herein.

  13. Characterization of Orbital Debris via Hyper-Velocity Laboratory-Based Tests

    NASA Technical Reports Server (NTRS)

    Cowardin, Heather; Liou, J.-C.; Krisko, Paula; Opiela, John; Fitz-Coy, Norman; Sorge, Marlon; Huynh, Tom

    2017-01-01

    Existing DoD and NASA satellite breakup models are based on a key laboratory test, Satellite Orbital debris Characterization Impact Test (SOCIT), which has supported many applications and matched on-orbit events involving older satellite designs reasonably well over the years. In order to update and improve these models, the NASA Orbital Debris Program Office, in collaboration with the Air Force Space and Missile Systems Center, The Aerospace Corporation, and the University of Florida, replicated a hypervelocity impact using a mock-up satellite, DebriSat, in controlled laboratory conditions. DebriSat is representative of present-day LEO satellites, built with modern spacecraft materials and construction techniques. Fragments down to 2 mm in size will be characterized by their physical and derived properties. A subset of fragments will be further analyzed in laboratory radar and optical facilities to update the existing radar-based NASA Size Estimation Model (SEM) and develop a comparable optical-based SEM. A historical overview of the project, status of the characterization process, and plans for integrating the data into various models will be discussed herein.

  14. Thermal-Structures and Materials Testing Laboratory

    NASA Technical Reports Server (NTRS)

    Teate, Anthony A.

    1997-01-01

    Since its inception and successful implementation in 1997 at James Madison University, the Thermal Structures and Materials Testing Laboratory (T-SaMTL) funded by the NASA Langley Research Center is evolving into one of the University's premier and exemplary efforts to increase minority representation in the sciences and mathematics. Serving ten (10) students and faculty directly and almost fifty (50) students indirectly, T-SAMTL, through its recruitment efforts, workshops, mentoring program, tutorial services and its research and computational laboratories has marked the completion of the first year with support from NASA totaling $ 100,000. Beginning as an innovative academic research and mentoring program for underrepresented minority science and mathematics students, the program now boasts a constituency which consists of 50% graduating seniors in the spring of 1998 with 50% planning to go to graduate school. The program's intent is to increase the number of underrepresented minorities who receive doctoral degrees in the sciences by initiating an academically enriched research program aimed at strengthening the academic and self actualization skills of undergraduate students with the potential to pursue doctoral study in the sciences. The program provides financial assistance, academic enrichment, and professional and personal development support for minority students who demonstrate the potential and strong desire to pursue careers in the sciences and mathematics. James Madison University was awarded the first $100,000, in April 1997, by The NASA Langley Research Center for establishment and support of its Thermal Structures and Materials Testing

  15. 42 CFR 493.1403 - Condition: Laboratories performing moderate complexity testing; laboratory director.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate complexity testing; laboratory director. 493.1403 Section 493.1403 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  16. 42 CFR 493.1403 - Condition: Laboratories performing moderate complexity testing; laboratory director.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing moderate complexity testing; laboratory director. 493.1403 Section 493.1403 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  17. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    PubMed

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  18. Laboratory development and testing of spacecraft diagnostics

    NASA Astrophysics Data System (ADS)

    Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric

    2017-10-01

    The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.

  19. Routine admission laboratory testing for general medical patients.

    PubMed

    Hubbell, F A; Frye, E B; Akin, B V; Rucker, L

    1988-06-01

    We evaluated the usefulness of commonly ordered routine admission laboratory tests in 301 patients admitted consecutively to the internal medicine wards of a university teaching hospital. Using a consensus analysis approach, three Department of Medicine faculty members reviewed the charts of admitted patients to determine the impact of the test results on patient care. The evaluated tests were the urinalysis, hematocrit, white blood cell count, platelet count, six-factor automated multiple analysis (serum sodium, potassium, chloride, bicarbonate, glucose, and blood urea nitrogen), prothrombin time, partial thromboplastin time, chest x-ray, and electrocardiogram. Forty-five percent of the 3,684 tests were ordered for patients without recognizable medical indications. Twelve percent of these routine tests were abnormal, 5% led to additional laboratory testing, but only 0.5% led to change in the treatment of patients. We conclude that the impact of routine admission laboratory testing on patient care is very small and that there is little justification for ordering tests solely because of hospital admission.

  20. Using pathology-specific laboratory profiles in Clinical Pathology to reduce inappropriate test requesting: two completed audit cycles

    PubMed Central

    2012-01-01

    Background Systematic reviews have shown that, although well prepared, the Consensus Guidelines have failed to change clinical practice. In the healthcare district of Castelnovo né Monti (Reggio Emilia, Italy), it became necessary for the GPs and Clinical Pathologists to work together to jointly define laboratory profiles. Methods Observational study with two cycles of retrospective audit on test request forms, in a primary care setting. Objectives of the study were to develop pathology-specific laboratory profiles and to increase the number of provisional diagnoses on laboratory test request forms. A Multiprofessional Multidisciplinary Inter-hospital Work Team developed pathology-specific laboratory profiles for more effective test requesting. After 8 training sessions that used a combined strategy with multifaceted interventions, the 23 General Practitioners (GPs) in the trial district (Castelnovo nè Monti) tested the profiles; the 21 GPs in the Puianello district were the control group; all GPs in both districts participated in the trial. All laboratory tests for both healthcare districts are performed at the Laboratory located in the trial district. A baseline and a 1-year audit were performed in both districts on the GPs’ request forms. Results Seven pathology-specific laboratory profiles for outpatients were developed. In the year after the first audit cycle: 1) the number of tests requested in the trial district was distinctly lower than that in the previous year, with a decrease of about 5% (p < 0.001); 2) the provisional diagnosis on the request forms was 52.8% in the trial district and 42% in the control district (P < 0.001); 3) the decrease of the number of tests on each request form was much more marked in the trial district (8.73 vs. 10.77; p < 0.001). Conclusions The first audit cycle showed a significant decrease in the number of tests ordered only in the trial district. The combined strategy used in this study improved the

  1. Using pathology-specific laboratory profiles in clinical pathology to reduce inappropriate test requesting: two completed audit cycles.

    PubMed

    Baricchi, Roberto; Zini, Michele; Nibali, Maria Grazia; Vezzosi, Walter; Insegnante, Vincenzo; Manfuso, Clotilde; Polese, Alessandra; Costoli, Valmer; Spelti, Antonio; Formisano, Debora; Orlandini, Danilo; Nicolini, Fausto; Poli, Antonio

    2012-07-03

    Systematic reviews have shown that, although well prepared, the Consensus Guidelines have failed to change clinical practice. In the healthcare district of Castelnovo né Monti (Reggio Emilia, Italy), it became necessary for the GPs and Clinical Pathologists to work together to jointly define laboratory profiles. Observational study with two cycles of retrospective audit on test request forms, in a primary care setting. Objectives of the study were to develop pathology-specific laboratory profiles and to increase the number of provisional diagnoses on laboratory test request forms. A Multiprofessional Multidisciplinary Inter-hospital Work Team developed pathology-specific laboratory profiles for more effective test requesting. After 8 training sessions that used a combined strategy with multifaceted interventions, the 23 General Practitioners (GPs) in the trial district (Castelnovo nè Monti) tested the profiles; the 21 GPs in the Puianello district were the control group; all GPs in both districts participated in the trial. All laboratory tests for both healthcare districts are performed at the Laboratory located in the trial district. A baseline and a 1-year audit were performed in both districts on the GPs' request forms. Seven pathology-specific laboratory profiles for outpatients were developed. In the year after the first audit cycle: 1) the number of tests requested in the trial district was distinctly lower than that in the previous year, with a decrease of about 5% (p < 0.001); 2) the provisional diagnosis on the request forms was 52.8% in the trial district and 42% in the control district (P < 0.001); 3) the decrease of the number of tests on each request form was much more marked in the trial district (8.73 vs. 10.77; p < 0.001). The first audit cycle showed a significant decrease in the number of tests ordered only in the trial district. The combined strategy used in this study improved the prescriptive compliance of most of the GPs involved

  2. Methodology in diagnostic laboratory test research in clinical chemistry and clinical chemistry and laboratory medicine.

    PubMed

    Lumbreras-Lacarra, Blanca; Ramos-Rincón, José Manuel; Hernández-Aguado, Ildefonso

    2004-03-01

    The application of epidemiologic principles to clinical diagnosis has been less developed than in other clinical areas. Knowledge of the main flaws affecting diagnostic laboratory test research is the first step for improving its quality. We assessed the methodologic aspects of articles on laboratory tests. We included articles that estimated indexes of diagnostic accuracy (sensitivity and specificity) and were published in Clinical Chemistry or Clinical Chemistry and Laboratory Medicine in 1996, 2001, and 2002. Clinical Chemistry has paid special attention to this field of research since 1996 by publishing recommendations, checklists, and reviews. Articles were identified through electronic searches in Medline. The strategy combined the Mesh term "sensitivity and specificity" (exploded) with the text words "specificity", "false negative", and "accuracy". We examined adherence to seven methodologic criteria used in the study by Reid et al. (JAMA1995;274:645-51) of papers published in general medical journals. Three observers evaluated each article independently. Seventy-nine articles fulfilled the inclusion criteria. The percentage of studies that satisfied each criterion improved from 1996 to 2002. Substantial improvement was observed in reporting of the statistical uncertainty of indices of diagnostic accuracy, in criteria based on clinical information from the study population (spectrum composition), and in avoidance of workup bias. Analytical reproducibility was reported frequently (68%), whereas information about indeterminate results was rarely provided. The mean number of methodologic criteria satisfied showed a statistically significant increase over the 3 years in Clinical Chemistry but not in Clinical Chemistry and Laboratory Medicine. The methodologic quality of the articles on diagnostic test research published in Clinical Chemistry and Clinical Chemistry and Laboratory Medicine is comparable to the quality observed in the best general medical journals

  3. 1. VIEW EAST, COMPONENTS TEST LABORATORY SHOWING CATCH BASINS, TURBINE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW EAST, COMPONENTS TEST LABORATORY SHOWING CATCH BASINS, TURBINE TESTING AREA, AND PUMP TESTING TOWER. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL

  4. Laboratory testing of Alcoscan saliva-alcohol test strips

    DOT National Transportation Integrated Search

    1986-10-01

    This report describes a laboratory evaluation of Alcoscan saliva-alcohol test strips. The objectives of this work were: (1) to determine the precision and accuracy of the Alcoscan strips; and (2) to determine what effect extreme ambient temperatures ...

  5. Performance Evaluation of "Low-cost" Sensors for Measuring Gaseous and Particle Air Pollutants: Results from Two Years of Field and Laboratory Testing

    NASA Astrophysics Data System (ADS)

    Feenstra, B. J.; Polidori, A.; Tisopulos, L.; Papapostolou, V.; Zhang, H.; Pathmanabhan, J.

    2016-12-01

    In recent years great progress has been made in development of low-cost miniature air quality sensing technologies. Such low-cost sensors offer a prospect of providing a real-time spatially dense information on pollutants, however, the quality of the data produced by these sensors is so far untested. In an effort to inform the general public about the actual performance of commercially available low-cost air quality sensors, in June 2014 the South Coast Air Quality Management District (SCAQMD) has established the Air Quality Sensor Performance Evaluation Center (AQ-SPEC). This program performs a thorough characterization of low-cost sensors under ambient (in the field) and controlled (in the laboratory) conditions. During the field testing, air quality sensors are operated side-by-side with Federal Reference Methods and Federal Equivalent Methods (FRM and FEM, respectively), which are routinely used to measure the ambient concentration of gaseous or particle pollutants for regulatory purposes. Field testing is conducted at two of SCAQMD's existing air monitoring stations, one in Rubidoux and one near the I-710 freeway. Sensors that demonstrate an acceptable performance in the field are brought back to the lab where a "characterization chamber" is used to challenge these devices with known concentrations of different particle and gaseous pollutants under different temperature and relative humidity levels. Testing results for each sensor are then summarized in a technical report and, along with other relevant information, posted online on a dedicated website (www.aqmd.gov/aq-spec) to educate the public about the capabilities of commercially available sensors and their potential applications. During this presentation, the results from two years of field and laboratory testing will be presented. The major strengths and weaknesses of some of the most commonly available particle and gaseous sensors will be discussed.

  6. Quality-assurance results for routine water analysis in US Geological Survey laboratories, water year 1991

    USGS Publications Warehouse

    Maloney, T.J.; Ludtke, A.S.; Krizman, T.L.

    1994-01-01

    phosphorus. A negative or positive bias condition was indicated in three of five nutrient constituents. There was acceptable precision and no indication of bias for the 14 low ionic-strength analytical procedures tested in the National Water Quality Laboratory program and for the 32 inorganic and 5 nutrient analytical procedures tested in the Quality of Water Service Unit during water year 1991.

  7. Reduction in Unnecessary Clinical Laboratory Testing Through Utilization Management at a US Government Veterans Affairs Hospital.

    PubMed

    Konger, Raymond L; Ndekwe, Paul; Jones, Genea; Schmidt, Ronald P; Trey, Marty; Baty, Eric J; Wilhite, Denise; Munshi, Imtiaz A; Sutter, Bradley M; Rao, Maddamsetti; Bashir, Chowdry M

    2016-03-01

    To implement an electronic laboratory utilization management system (laboratory expert system [LES]) to provide safe and effective reductions in unnecessary clinical laboratory testing. The LES is a set of frequency filter subroutines within the Veterans Affairs hospital and laboratory information system that was formulated by an interdisciplinary medical team. Since implementing the LES, total test volume has decreased by a mean of 11.18% per year compared with our pre-LES test volume. This change was not attributable to fluctuations in outpatient visits or inpatient days of care. Laboratory cost savings were estimated at $151,184 and $163,751 for 2012 and 2013, respectively. A significant portion of these cost savings was attributable to reductions in high-volume, large panel testing. No adverse effects on patient care were reported, and mean length of stay for patients remained unchanged. Electronic laboratory utilization systems can effectively reduce unnecessary laboratory testing without compromising patient care. Published by Oxford University Press on behalf of the American Society for Clinical Pathology, 2016. This work is written by US Government employees and is in the public domain in the US.

  8. Laboratory and clinical evaluation of on-site urine drug testing.

    PubMed

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  9. Collaborative Testing in Practical Laboratories: An Effective Teaching-Learning Method in Histology.

    PubMed

    Guo, Yuping; Li, Enzhong

    2016-01-01

    This article presents an experimental teaching and learning program used in histology with first-year students in the second term in the Faculty of Biology at Huanghuai University, China. Eighty-six students were divided randomly into two groups (n=43 per group). Tests were conducted at the end of each practical laboratory (10 laboratories in total) in which collaborative testing was used in the experimental group and traditional testing in the control group. To assess achievement, a final examination in histology was carried out at the end of the course. To determine students' attitude to the teaching styles, a questionnaire survey was conducted at the end of the term. Results showed that students preferred the collaborative testing format. In the experimental group, students' scores were significantly higher than those of students in the control group in final examinations. These findings indicate that collaborative testing enhances student learning and understanding of the material taught, and suggest that collaborative testing is an effective teaching-learning method in histology.

  10. A system dynamics approach to analyze laboratory test errors.

    PubMed

    Guo, Shijing; Roudsari, Abdul; Garcez, Artur d'Avila

    2015-01-01

    Although many researches have been carried out to analyze laboratory test errors during the last decade, it still lacks a systemic view of study, especially to trace errors during test process and evaluate potential interventions. This study implements system dynamics modeling into laboratory errors to trace the laboratory error flows and to simulate the system behaviors while changing internal variable values. The change of the variables may reflect a change in demand or a proposed intervention. A review of literature on laboratory test errors was given and provided as the main data source for the system dynamics model. Three "what if" scenarios were selected for testing the model. System behaviors were observed and compared under different scenarios over a period of time. The results suggest system dynamics modeling has potential effectiveness of helping to understand laboratory errors, observe model behaviours, and provide a risk-free simulation experiments for possible strategies.

  11. Iowa Central Quality Fuel Testing Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heach, Don; Bidieman, Julaine

    2013-09-30

    The objective of this project is to finalize the creation of an independent quality fuel testing laboratory on the campus of Iowa Central Community College in Fort Dodge, Iowa that shall provide the exploding biofuels industry a timely and cost-effective centrally located laboratory to complete all state and federal fuel and related tests that are required. The recipient shall work with various state regulatory agencies, biofuel companies and state and national industry associations to ensure that training and testing needs of their members and American consumers are met. The recipient shall work with the Iowa Department of Ag and Landmore » Stewardship on the development of an Iowa Biofuel Quality Standard along with the Development of a standard that can be used throughout industry.« less

  12. Request of laboratory liver tests in primary care in Spain: potential savings if appropriateness indicator targets were achieved.

    PubMed

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-10-01

    Liver laboratory tests are used to screen for liver disease, suggest the underlying cause, estimate the severity, assess prognosis, and monitor the efficacy of therapy. The aim of this study was to compare the liver laboratory tests requesting patterns by GPs in Spain, according to geographic and hospital characteristics, to investigate the degree of requesting appropriateness. One hundred and forty-one clinical laboratories were invited to participate from diverse regions across Spain. They filed out the number of laboratory liver tests requested by GPs for the year 2012. Two types of appropriateness indicators were calculated: every test request per 1000 inhabitants or ratios of related tests requests. The indicator results obtained were compared between the different hospitals, according to their setting, location, and management. The savings generated, if each area would have achieved indicator targets, were calculated. We recruited 76 laboratories covering a population of 17,679,195 inhabitants. GPs requested 20,916,780 laboratory liver tests in the year 2012. No differences were obtained according to their setting. Lactate dehydrogenase and direct bilirubin per 1000 inhabitants were significantly higher in institutions with private management. Largest differences were observed between communities. Nine, 31, 0, and 13 laboratories, respectively, achieved the aspartate aminotransferase, lactate dehydrogenase, γ-glutamyl transpeptidase, and total bilirubin-related alanine aminotransferase indicator targets. Reaching ratios would have resulted in savings of €1,028,468. There was a high variability in the request of liver tests. This emphasizes the need to implement interventions to improve appropriate use of liver tests.

  13. Reference values for 34 frequently used laboratory tests in 80-year-old men and women.

    PubMed

    Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders

    2016-10-01

    Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. CTBTO Contractor Laboratory Test Sample Production Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bob Hague; Tracy Houghton; Nick Mann

    2013-08-01

    In October 2012 scientists from both Idaho National Laboratory (INL) and the CTBTO contact laboratory at Seibersdorf, Austria designed a system and capability test to determine if the INL could produce and deliver a short lived radio xenon standard in time for the standard to be measured at the CTBTO contact laboratory at Seibersdorf, Austria. The test included sample standard transportation duration and potential country entrance delays at customs. On October 23, 2012 scientists at the Idaho National Laboratory (INL) prepared and shipped a Seibersdorf contract laboratory supplied cylinder. The canister contained 1.0 scc of gas that consisted of 70%more » xenon and 30% nitrogen by volume. The t0 was October 24, 2012, 1200 ZULU. The xenon content was 0.70 +/ 0.01 scc at 0 degrees C. The 133mXe content was 4200 +/ 155 dpm per scc of stable xenon on t0 (1 sigma uncertainty). The 133Xe content was 19000 +/ 800 dpm per scc of stable xenon on t0 (1 sigma uncertainty).« less

  15. Parachute Testing for Mars Science Laboratory

    NASA Technical Reports Server (NTRS)

    2007-01-01

    The team developing the landing system for NASA's Mars Science Laboratory tested the deployment of an early parachute design in mid-October 2007 inside the world's largest wind tunnel, at NASA Ames Research Center, Moffett Field, California.

    In this image, an engineer is dwarfed by the parachute, which holds more air than a 280-square-meter (3,000-square-foot) house and is designed to survive loads in excess of 36,000 kilograms (80,000 pounds).

    The parachute, built by Pioneer Aerospace, South Windsor, Connecticut, has 80 suspension lines, measures more than 50 meters (165 feet) in length, and opens to a diameter of nearly 17 meters (55 feet). It is the largest disk-gap-band parachute ever built and is shown here inflated in the test section with only about 3.8 meters (12.5 feet) of clearance to both the floor and ceiling.

    The wind tunnel, which is 24 meters (80 feet) tall and 37 meters (120 feet) wide and big enough to house a Boeing 737, is part of the National Full-Scale Aerodynamics Complex, operated by the U.S. Air Force, Arnold Engineering Development Center.

    NASA's Jet Propulsion Laboratory, Pasadena, California, is building and testing the Mars Science Laboratory spacecraft for launch in 2009. The mission will land a roving analytical laboratory on the surface of Mars in 2010. JPL is a division of the California Institute of Technology.

  16. Inter-laboratory Comparison of Three Earplug Fit-test Systems

    PubMed Central

    Byrne, David C.; Murphy, William J.; Krieg, Edward F.; Ghent, Robert M.; Michael, Kevin L.; Stefanson, Earl W.; Ahroon, William A.

    2017-01-01

    The National Institute for Occupational Safety and Health (NIOSH) sponsored tests of three earplug fit-test systems (NIOSH HPD Well-Fit™, Michael & Associates FitCheck, and Honeywell Safety Products VeriPRO®). Each system was compared to laboratory-based real-ear attenuation at threshold (REAT) measurements in a sound field according to ANSI/ASA S12.6-2008 at the NIOSH, Honeywell Safety Products, and Michael & Associates testing laboratories. An identical study was conducted independently at the U.S. Army Aeromedical Research Laboratory (USAARL), which provided their data for inclusion in this report. The Howard Leight Airsoft premolded earplug was tested with twenty subjects at each of the four participating laboratories. The occluded fit of the earplug was maintained during testing with a soundfield-based laboratory REAT system as well as all three headphone-based fit-test systems. The Michael & Associates lab had highest average A-weighted attenuations and smallest standard deviations. The NIOSH lab had the lowest average attenuations and the largest standard deviations. Differences in octave-band attenuations between each fit-test system and the American National Standards Institute (ANSI) sound field method were calculated (Attenfit-test - AttenANSI). A-weighted attenuations measured with FitCheck and HPD Well-Fit systems demonstrated approximately ±2 dB agreement with the ANSI sound field method, but A-weighted attenuations measured with the VeriPRO system underestimated the ANSI laboratory attenuations. For each of the fit-test systems, the average A-weighted attenuation across the four laboratories was not significantly greater than the average of the ANSI sound field method. Standard deviations for residual attenuation differences were about ±2 dB for FitCheck and HPD Well-Fit compared to ±4 dB for VeriPRO. Individual labs exhibited a range of agreement from less than a dB to as much as 9.4 dB difference with ANSI and REAT estimates. Factors such as

  17. 30 CFR 14.21 - Laboratory-scale flame test apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Laboratory-scale flame test apparatus. 14.21 Section 14.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... Technical Requirements § 14.21 Laboratory-scale flame test apparatus. The principal parts of the apparatus...

  18. 30 CFR 14.21 - Laboratory-scale flame test apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Laboratory-scale flame test apparatus. 14.21 Section 14.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... Technical Requirements § 14.21 Laboratory-scale flame test apparatus. The principal parts of the apparatus...

  19. Fifteen Years of Laboratory Astrophysics at Ames

    NASA Technical Reports Server (NTRS)

    Allamandola, L. J.; Sandford, S. A.; Salama, F.; Hudgins, D. M.; Bernstein, M.; Goorvitch, David (Technical Monitor)

    1998-01-01

    Tremendous strides have been made in our understanding of interstellar material over the past fifteen years thanks to significant, parallel developments in two closely related areas: observational astronomy and laboratory astrophysics. Fifteen years ago the composition of interstellar dust was largely guessed at, the concept of ices in dense molecular clouds ignored, and the notion of large, abundant, gas phase, carbon-rich molecules widespread throughout the interstellar medium (ISM) considered impossible. Today the composition of dust in the diffuse ISM is reasonably well constrained to cold refractory materials comprised of amorphous and crystalline silicates mixed with an amorphous carbonaceous material containing aromatic structural units and short, branched aliphatic chains. In the dense ISM, these cold dust particles are coated with mixed-molecular ices whose compositions are very well known. Lastly, the signature of carbon-rich polycyclic aromatic hydrocarbons (PAHs), shockingly large molecules by early interstellar chemistry standards, is widespread throughout the ISM. This great progress has only been made possible by the close collaboration of laboratory experimentalists with observers and theoreticians, all with the goal of applying their skills to astrophysical problems of direct interest to NASA programs. Such highly interdisciplinary collaborations ensure fundamental, in depth coverage of the wide-ranging challenges posed by astrophysics. These challenges include designing astrophysically focused experiments and data analysis, tightly coupled with astrophysical searches spanning 2 orders of magnitude in wavelength, and detailed theoretical modeling. The impact of our laboratory has been particularly effective as there is constant cross-talk and feedback between quantum theorists; theoretical astrophysicists and chemists; experimental physicists; organic, physical and petroleum chemists; and infrared and UV/Vis astronomers. In this paper, two examples

  20. 11. Interior view of control room in Components Test Laboratory ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Interior view of control room in Components Test Laboratory (T-27), looking north. Photograph shows upgraded instrumentation, piping, and technological modifications installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  1. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  2. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  3. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  4. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  5. 19 CFR 151.71 - Laboratory testing for clean yield.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.71... director. (b) Notification to importer. Where samples of wool or hair have been tested in a Customs... laboratory test is not feasible, the wool or hair may be retested by a commercial laboratory in accordance...

  6. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  7. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  8. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  9. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  10. 7 CFR 58.523 - Laboratory and quality control tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  11. The development of Metacognition test in genetics laboratory for undergraduate students

    NASA Astrophysics Data System (ADS)

    A-nongwech, Nattapong; Pruekpramool, Chaninan

    2018-01-01

    The purpose of this research was to develop a Metacognition test in a Genetics Laboratory for undergraduate students. The participants were 30 undergraduate students of a Rajabhat university in Rattanakosin group in the second semester of the 2016 academic year using purposive sampling. The research instrument consisted of 1) Metacognition test and 2) a Metacognition test evaluation form for experts focused on three main points which were an accurate evaluation form of content, a consistency between Metacognition experiences and questions and the appropriateness of the test. The quality of the test was analyzed by using the Index of Consistency (IOC), discrimination and reliability. The results of developing Metacognition test were summarized as 1) The result of developing Metacognition test in a Genetics Laboratory for undergraduate students found that the Metacognition test contained 56 items of open - ended questions. The test composed of 1) four scientific situations, 2) fourteen items of open - ended questions in each scientific situation for evaluating components of Metacognition. The components of Metacognition consisted of Metacognitive knowledge, which were divided into person knowledge, task knowledge and strategy knowledge and Metacognitive experience, which were divided into planning, monitoring and evaluating, and 3) fourteen items of scoring criteria divided into four scales. 2) The results of the item analysis of Metacognition in Genetics Laboratory for undergraduate students found that Index of Consistency between Metacognitive experiences and questions were in the range between 0.75 - 1.00. An accuracy of content equaled 1.00. The appropriateness of the test equaled 1.00 in all situations and items. The discrimination of the test was in the range between 0.00 - 0.73. Furthermore, the reliability of the test equaled 0.97.

  12. Nuclear Test-Experimental Science: Annual report, fiscal year 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Struble, G.L.; Donohue, M.L.; Bucciarelli, G.

    1988-01-01

    Fiscal year 1988 has been a significant, rewarding, and exciting period for Lawrence Livermore National Laboratory's nuclear testing program. It was significant in that the Laboratory's new director chose to focus strongly on the program's activities and to commit to a revitalized emphasis on testing and the experimental science that underlies it. It was rewarding in that revolutionary new measurement techniques were fielded on recent important and highly complicated underground nuclear tests with truly incredible results. And it was exciting in that the sophisticated and fundamental problems of weapons science that are now being addressed experimentally are yielding new challengesmore » and understanding in ways that stimulate and reward the brightest and best of scientists. During FY88 the program was reorganized to emphasize our commitment to experimental science. The name of the program was changed to reflect this commitment, becoming the Nuclear Test-Experimental Science (NTES) Program.« less

  13. 18. Interior view of HVAC room in Components Test Laboratory ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Interior view of HVAC room in Components Test Laboratory (T-27), showing northwest corner. Photograph shows upgraded instrumentation, piping, and technological modifications for HVAC system installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  14. 19. Interior view of HVAC room in Components Test Laboratory ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Interior view of HVAC room in Components Test Laboratory (T-27), looking toward east wall. Photograph shows upgraded instrumentation, machinery, and technological modifications for HVAC system installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  15. 5. AERIAL PHOTO OF THE COMPONENTS TEST LABORATORY DURING THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. AERIAL PHOTO OF THE COMPONENTS TEST LABORATORY DURING THE CONSTRUCTION OF THE EAST TEST AREA. 1955, FRED ORDWAY COLLECTION, U.S. SPACE AND ROCKET CENTER, HUNTSVILLE, AL. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL

  16. Extracting laboratory test information from biomedical text

    PubMed Central

    Kang, Yanna Shen; Kayaalp, Mehmet

    2013-01-01

    Background: No previous study reported the efficacy of current natural language processing (NLP) methods for extracting laboratory test information from narrative documents. This study investigates the pathology informatics question of how accurately such information can be extracted from text with the current tools and techniques, especially machine learning and symbolic NLP methods. The study data came from a text corpus maintained by the U.S. Food and Drug Administration, containing a rich set of information on laboratory tests and test devices. Methods: The authors developed a symbolic information extraction (SIE) system to extract device and test specific information about four types of laboratory test entities: Specimens, analytes, units of measures and detection limits. They compared the performance of SIE and three prominent machine learning based NLP systems, LingPipe, GATE and BANNER, each implementing a distinct supervised machine learning method, hidden Markov models, support vector machines and conditional random fields, respectively. Results: Machine learning systems recognized laboratory test entities with moderately high recall, but low precision rates. Their recall rates were relatively higher when the number of distinct entity values (e.g., the spectrum of specimens) was very limited or when lexical morphology of the entity was distinctive (as in units of measures), yet SIE outperformed them with statistically significant margins on extracting specimen, analyte and detection limit information in both precision and F-measure. Its high recall performance was statistically significant on analyte information extraction. Conclusions: Despite its shortcomings against machine learning methods, a well-tailored symbolic system may better discern relevancy among a pile of information of the same type and may outperform a machine learning system by tapping into lexically non-local contextual information such as the document structure. PMID:24083058

  17. 10. Interior view of control room in Components Test Laboratory ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Interior view of control room in Components Test Laboratory (T-27), looking east. The control room is located in the center of the building and abuts the Test Cell 8, 9, and 10 and equipment room wings. Photograph shows upgraded instrumentation, piping, and technological modifications installed in 1997-99 to accommodate component testing requirements for the Atlas V missile. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  18. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    PubMed

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  19. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Choosing the right laboratory: a review of clinical and forensic toxicology services for urine drug testing in pain management.

    PubMed

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2015-01-01

    Urine drug testing (UDT) services are provided by a variety of clinical, forensic, and reference/specialty laboratories. These UDT services differ based on the principal activity of the laboratory. Clinical laboratories provide testing primarily focused on medical care (eg, emergency care, inpatients, and outpatient clinics), whereas forensic laboratories perform toxicology tests related to postmortem and criminal investigations, and drug-free workplace programs. Some laboratories now provide UDT specifically designed for monitoring patients on chronic opioid therapy. Accreditation programs for clinical laboratories have existed for nearly half a century, and a federal certification program for drug-testing laboratories was established in the 1980s. Standards of practice for forensic toxicology services other than workplace drug testing have been established in recent years. However, no accreditation program currently exists for UDT in pain management, and this review considers several aspects of laboratory accreditation and certification relevant to toxicology services, with the intention to provide guidance to clinicians in their selection of the appropriate laboratory for UDT surveillance of their patients on opioid therapy.

  1. Selective testing of women based on age for genital Chlamydia trachomatis and Neisseria gonorrhoeae infection in a centralized regional microbiology laboratory.

    PubMed

    Church, Deirdre L; Amante, L; Semeniuk, H; Gregson, D B

    2007-04-01

    Calgary Laboratory Services, Alberta, Canada, provides microbiology services via a centralized laboratory to the Calgary Health Region. A selective genital Chlamydia trachomatis (CT)/Neisseria gonorrhoeae (GC) testing policy for women >35 years was implemented. The changes in physician ordering practice, the rate of detection of infections, and the test turnaround times were monitored. The volume of tests, the cost/test, and the total service costs accrued in the year before and after this policy change were compared. An immediate impact was a 30% decrease in tests performed due to the laboratory rejecting samples from older women. Subsequently, physicians' practice changed so that tests were ordered when test criteria were met. Detection rates did not change in any age group. A 27.9% decrease in the total service costs resulted in a labor reduction of 0.2 FTE. Selective testing of women >35 years with a low prevalence of CT/GC infection is clinically relevant and cost-effective.

  2. 42 CFR 493.25 - Laboratories performing tests of high complexity.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND....25 Laboratories performing tests of high complexity. (a) A laboratory must obtain a certificate for...

  3. 42 CFR 493.25 - Laboratories performing tests of high complexity.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND....25 Laboratories performing tests of high complexity. (a) A laboratory must obtain a certificate for...

  4. Cruise Stage Testing for Mars Science Laboratory

    NASA Image and Video Library

    2010-09-02

    Testing of the cruise stage for NASA Mars Science Laboratory in August 2010 included a session in a facility that simulates the environment found in interplanetary space. Spacecraft technicians at JPL prepare a space-simulation test.

  5. 4. Exterior view of Components Test Laboratory (T27), looking northeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Exterior view of Components Test Laboratory (T-27), looking northeast. The building wing on the left houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault, and that on the right houses Test Cell 10 (environmental). - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  6. 5. Exterior view of Components Test Laboratory (T27), looking northwest. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Exterior view of Components Test Laboratory (T-27), looking northwest. The building wing on the left houses Test Cell 10 (environmental), and that on the right houses Test Cell 9 (fuel) and the fuel storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  7. [National External Quality Assessment for medical biology laboratories in Burkina Faso: an overview of three years of activity].

    PubMed

    Sakande, Jean; Nikièma, Abdoulaye; Kabré, Elie; Nacoulma, Eric; Sawadogo, Charles; Lingani, Virginie; Traoré, Lady Kady; Kouanda, Abdoulaye; Kientéga, Youssouf; Somda, Joseph; Kagambéga, Faustin; Sanou, Mahamoudou; Sangaré, Lassana; Traoré-Ouédraogo, Rasmata

    2010-01-01

    We report results of the National External Quality Assessment for (NEQA) laboratories in Burkina Faso, a country with limited resources located in West Africa whose epidemiology is dominated by infectious diseases. The national laboratory network consists of 160 laboratories including 40 private. The Government of Burkina Faso has adopted a national laboratory policy. One of the objectives of this policy is to improve the quality of laboratory results. One of the strategies to achieve this objective is the establishment of a NEQA. The NEQA is a panel testing also called proficiency testing. It is mandatory for all laboratories to participate to the NEQA. The NEQA is organized twice a year and covers all areas of laboratories (bacteriology-virology, biochemistry, hematology, parasitology and immunology). The review of three years of activity (2006-2008) shows the following results: (1) for microscopic examination of bacteria after Gram staining, the error rate decreased from 24.7% in 2006 to 13.1% in 2007 and 13% in 2008; (2) errors rate in reading slides for the microscopic diagnosis of malaria were 23.4%, 14.6% and 10.2% respectively in 2006, 2007 and 2008; (3) for biochemistry, the percentages of unsatisfactory results were respectively 12.5%, 14.8% and 13.8% in 2006, 2007 and 2008 for the overall parameters assessed. The analysis of the results generated by the laboratories during these three years shows a quality improvement. However, the NEQA should be strengthened through ongoing training and quality control of reagents and equipment.

  8. 42 CFR 493.25 - Laboratories performing tests of high complexity.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Provisions § 493.25 Laboratories performing tests of high...

  9. 42 CFR 493.20 - Laboratories performing tests of moderate complexity.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Laboratories performing tests of moderate complexity. 493.20 Section 493.20 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Provisions § 493.20 Laboratories performing tests of...

  10. High-Value, Cost-Conscious Care: Iterative Systems-Based Interventions to Reduce Unnecessary Laboratory Testing.

    PubMed

    Sadowski, Brett W; Lane, Alison B; Wood, Shannon M; Robinson, Sara L; Kim, Chin Hee

    2017-09-01

    Inappropriate testing contributes to soaring healthcare costs within the United States, and teaching hospitals are vulnerable to providing care largely for academic development. Via its "Choosing Wisely" campaign, the American Board of Internal Medicine recommends avoiding repetitive testing for stable inpatients. We designed systems-based interventions to reduce laboratory orders for patients admitted to the wards at an academic facility. We identified the computer-based order entry system as an appropriate target for sustainable intervention. The admission order set had allowed multiple routine tests to be ordered repetitively each day. Our iterative study included interventions on the automated order set and cost displays at order entry. The primary outcome was number of routine tests controlled for inpatient days compared with the preceding year. Secondary outcomes included cost savings, delays in care, and adverse events. Data were collected over a 2-month period following interventions in sequential years and compared with the year prior. The first intervention led to 0.97 fewer laboratory tests per inpatient day (19.4%). The second intervention led to sustained reduction, although by less of a margin than order set modifications alone (15.3%). When extrapolating the results utilizing fees from the Centers for Medicare and Medicaid Services, there was a cost savings of $290,000 over 2 years. Qualitative survey data did not suggest an increase in care delays or near-miss events. This series of interventions targeting unnecessary testing demonstrated a sustained reduction in the number of routine tests ordered, without adverse effects on clinical care. Published by Elsevier Inc.

  11. Project Laboratory for First-Year Students

    ERIC Educational Resources Information Center

    Planinsic, Gorazd

    2007-01-01

    This paper reports the modification of an existing experimental subject into a project laboratory for first-year physics students studying in the first cycle of university level and at a higher professional level. The subject is aimed at developing important science-related competences and skills through concrete steps under circumstances that are…

  12. Bridging naturalistic and laboratory assessment of memory: the Baycrest mask fit test.

    PubMed

    Armson, Michael J; Abdi, Hervé; Levine, Brian

    2017-09-01

    Autobiographical memory tests provide a naturalistic counterpoint to the artificiality of laboratory research methods, yet autobiographical events are uncontrolled and, in most cases, unverifiable. In this study, we capitalised on a scripted, complex naturalistic event - the mask fit test (MFT), a standardised procedure required of hospital employees - to bridge the gap between naturalistic and laboratory memory assessment. We created a test of recognition memory for the MFT and administered it to 135 hospital employees who had undertaken the MFT at various points over the past five years. Multivariate analysis revealed two dimensions defined by accuracy and response bias. Accuracy scores showed the expected relationship to encoding-test delay, supporting the validity of this measure. Relative to younger adults, older adults' memory for this naturalistic event was better than would be predicted from the cognitive ageing literature, a result consistent with the notion that older adults' memory performance is enhanced when stimuli are naturalistic and personally relevant. These results demonstrate that testing recognition memory for a scripted event is a viable method of studying autobiographical memory.

  13. Shield evaluation and performance testing at the USMB`s Strategic Structures Testing Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barczak, T.M.; Gearhart, D.F.

    1996-12-31

    Historically, shield performance testing is conducted by the support manufacturers at European facilities. The U.S. Bureau of Mines (USBM) has conducted extensive research in shield Mechanics and is now opening its Strategic Structures Testing (SST) Laboratory to the mining industry for shield performance testing. The SST Laboratory provides unique shield testing capabilities using the Mine Roof Simulator (MRS) load frame. The MRS provides realistic and cost-effective shield evaluation by combining both vertical and horizontal loading into a single load cycle; whereas, several load cycles would be required to obtain this loading in a static frame. In addition to these advantages,more » the USBM acts as an independent research organization to provide an unbiased assessment of shield performance. This paper describes the USBM`s shield testing program that is designed specifically to simulate in-service mining conditions using the unique the capabilities of the SST Laboratory.« less

  14. 7 CFR 58.442 - Laboratory and quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  15. 7 CFR 58.442 - Laboratory and quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  16. Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories

    PubMed Central

    Jang, Mi-Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong-Ho; Min, Won-Ki; Lee, Ji Sung

    2017-01-01

    Background Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. Methods We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Results Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. Conclusions These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. PMID:28224767

  17. Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories.

    PubMed

    Jang, Mi Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong Ho; Min, Won Ki; Lee, Ji Sung; Lee, Yong Wha; Lee, You Kyoung

    2017-05-01

    Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. © The Korean Society for Laboratory Medicine

  18. Could light meal jeopardize laboratory coagulation tests?

    PubMed

    Lima-Oliveira, Gabriel; Salvagno, Gian Luca; Lippi, Giuseppe; Danese, Elisa; Gelati, Matteo; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2014-01-01

    Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests. A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV). A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104-117) and 111 (107-120) vs. 109 (102-118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9-34.8) vs. 34.1 (32.2-35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV. A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake.

  19. Impact of providing fee data on laboratory test ordering: a controlled clinical trial.

    PubMed

    Feldman, Leonard S; Shihab, Hasan M; Thiemann, David; Yeh, Hsin-Chieh; Ardolino, Margaret; Mandell, Steven; Brotman, Daniel J

    2013-05-27

    Inpatient care providers often order laboratory tests without any appreciation for the costs of the tests. To determine whether we could decrease the number of laboratory tests ordered by presenting providers with test fees at the time of order entry in a tertiary care hospital, without adding extra steps to the ordering process. Controlled clinical trial. Tertiary care hospital. All providers, including physicians and nonphysicians, who ordered laboratory tests through the computerized provider order entry system at The Johns Hopkins Hospital. We randomly assigned 61 diagnostic laboratory tests to an "active" arm (fee displayed) or to a control arm (fee not displayed). During a 6-month baseline period (November 10, 2008, through May 9, 2009), we did not display any fee data. During a 6-month intervention period 1 year later (November 10, 2009, through May 9, 2010), we displayed fees, based on the Medicare allowable fee, for active tests only. We examined changes in the total number of orders placed, the frequency of ordered tests (per patient-day), and total charges associated with the orders according to the time period (baseline vs intervention period) and by study group (active test vs control). For the active arm tests, rates of test ordering were reduced from 3.72 tests per patient-day in the baseline period to 3.40 tests per patient-day in the intervention period (8.59% decrease; 95% CI, -8.99% to -8.19%). For control arm tests, ordering increased from 1.15 to 1.22 tests per patient-day from the baseline period to the intervention period (5.64% increase; 95% CI, 4.90% to 6.39%) (P < .001 for difference over time between active and control tests). Presenting fee data to providers at the time of order entry resulted in a modest decrease in test ordering. Adoption of this intervention may reduce the number of inappropriately ordered diagnostic tests.

  20. 42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...

  1. 42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...

  2. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.

    PubMed

    Plebani, Mario

    2017-07-01

    An important priority in the current healthcare scenario should be to address errors in laboratory testing, which account for a significant proportion of diagnostic errors. Efforts made in laboratory medicine to enhance the diagnostic process have been directed toward improving technology, greater volumes and more accurate laboratory tests being achieved, but data collected in the last few years highlight the need to re-evaluate the total testing process (TTP) as the unique framework for improving quality and patient safety. Valuable quality indicators (QIs) and extra-analytical performance specifications are required for guidance in improving all TTP steps. Yet in literature no data are available on extra-analytical performance specifications based on outcomes, and nor is it possible to set any specification using calculations involving biological variability. The collection of data representing the state-of-the-art based on quality indicators is, therefore, underway. The adoption of a harmonized set of QIs, a common data collection and standardised reporting method is mandatory as it will not only allow the accreditation of clinical laboratories according to the International Standard, but also assure guidance for promoting improvement processes and guaranteeing quality care to patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. 60 Years of Great Science (Oak Ridge National Laboratory)

    DOE R&D Accomplishments Database

    2003-01-01

    This issue of Oak Ridge National Laboratory Review (vol. 36, issue 1) highlights Oak Ridge National Laboratory's contributions in more than 30 areas of research and related activities during the past 60 years and provides glimpses of current activities that are carrying on this heritage.

  4. 2. Exterior view of Components Test Laboratory (T27), looking southeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Exterior view of Components Test Laboratory (T-27), looking southeast. The building wing on the left houses the equipment room and that on the right houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  5. 3. Exterior view of Components Test Laboratory (T27), looking southeast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Exterior view of Components Test Laboratory (T-27), looking southeast. The building wing on the left houses the equipment room, and that on the right houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  6. Parachute Testing for Mars Science Laboratory

    NASA Image and Video Library

    2007-12-20

    The team developing the landing system for NASA Mars Science Laboratory tested the deployment of an early parachute design in mid-October 2007 inside the world largest wind tunnel, at NASA Ames Research Center, Moffett Field, California.

  7. Airborne Proximity Warning Instrument Laboratory Tests

    DOT National Transportation Integrated Search

    1977-01-01

    An Airborne Proximity Warning Instrument (APWI) designed and manufactured by Rock Avionics, New York, was subjected to a short laboratory test at the Transportation Systems Center to determine the suitability of this product for further evaluation as...

  8. Albuquerque Seismological Laboratory--50 years of global seismology

    USGS Publications Warehouse

    Hutt, C.R.; Peterson, Jon; Gee, Lind; Derr, John; Ringler, Adam; Wilson, David

    2011-01-01

    The U.S. Geological Survey Albuquerque Seismological Laboratory is about 15 miles southeast of Albuquerque on the Pueblo of Isleta, adjacent to Kirtland Air Force Base. The Albuquerque Seismological Laboratory supports the Global Seismographic Network Program and the Advanced National Seismic System through the installation, operation, and maintenance of seismic stations around the world and serves as the premier seismological instrumentation test facility for the U.S. Government.

  9. The effects of total laboratory automation on the management of a clinical chemistry laboratory. Retrospective analysis of 36 years.

    PubMed

    Sarkozi, Laszlo; Simson, Elkin; Ramanathan, Lakshmi

    2003-03-01

    Thirty-six years of data and history of laboratory practice at our institution has enabled us to follow the effects of analytical automation, then recently pre-analytical and post-analytical automation on productivity, cost reduction and enhanced quality of service. In 1998, we began the operation of a pre- and post-analytical automation system (robotics), together with an advanced laboratory information system to process specimens prior to analysis, deliver them to various automated analytical instruments, specimen outlet racks and finally to refrigerated stockyards. By the end of 3 years of continuous operation, we compared the chemistry part of the system with the prior 33 years and quantitated the financial impact of the various stages of automation. Between 1965 and 2000, the Consumer Price Index increased by a factor of 5.5 in the United States. During the same 36 years, at our institution's Chemistry Department the productivity (indicated as the number of reported test results/employee/year) increased from 10,600 to 104,558 (9.3-fold). When expressed in constant 1965 dollars, the total cost per test decreased from 0.79 dollars to 0.15 dollars. Turnaround time for availability of results on patient units decreased to the extent that Stat specimens requiring a turnaround time of <1 h do not need to be separately prepared or prioritized on the system. Our experience shows that the introduction of a robotics system for perianalytical automation has brought a large improvement in productivity together with decreased operational cost. It enabled us to significantly increase our workload together with a reduction of personnel. In addition, stats are handled easily and there are benefits such as safer working conditions and improved sample identification, which are difficult to quantify at this stage.

  10. Are laboratory tests always needed? Frequency and causes of laboratory overuse in a hospital setting.

    PubMed

    Cadamuro, Janne; Gaksch, Martin; Wiedemann, Helmut; Lippi, Giuseppe; von Meyer, Alexander; Pertersmann, Astrid; Auer, Simon; Mrazek, Cornelia; Kipman, Ulrike; Felder, Thomas K; Oberkofler, Hannes; Haschke-Becher, Elisabeth

    2018-04-01

    Inappropriate utilization of laboratory resources is an increasing concern especially in high-throughput facilities. Until now, no reliable information has been published addressing to which extent laboratory results are actually used for clinical decision-making. Therefore, we aimed to close this gap using a novel retrospective approach including a survey of clinicians and nurses. We retrospectively evaluated the number of re-orders for potassium (K), lactate dehydrogenase (LD), aspartate-aminotransferase (AST), activated partial thromboplastin-time (APTT) and prothrombin-time/INR (PT/INR), after the initial order had to be cancelled due to preanalytical non-conformities. We analyzed subgroups regarding time to re-order, ward and sample priority (urgent vs. routine). Subsequently, we surveyed clinicians and nurses, asking for their estimate of the amount of failed re-orders as well as for possible reasons. From initially cancelled tests, only ~20% of K, LD, AST and ~30% of APTT and PT/INR tests were re-ordered within 24 h. 70% of the investigated clinical chemistry and 60% of coagulation tests were re-ordered one week after cancellation or not at all. Survey participants quite accurately estimated these numbers. Routine laboratory panels, short stay of out-patients, obsolete test results and avoiding additional phlebotomies were the main reasons for not re-ordering cancelled tests. Overall, 60-70% of test results in the investigated assays ordered in a high throughput laboratory are potentially inappropriate or of doubtful clinically importance. Although clinicians and nurses are aware of this situation, it is the duty of laboratory specialists to overcome overutilization in close collaboration with all involved healthcare workers. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Towards a rational antimicrobial testing policy in the laboratory.

    PubMed

    Banaji, N; Oommen, S

    2011-01-01

    Antimicrobial policy for prophylactic and therapeutic use of antimicrobials in a tertiary care setting has gained importance. A hospital's antimicrobial policy as laid down by its hospital infection control team needs to include inputs from the microbiology laboratory, besides the pharmacy and therapeutic committee. Therefore, it is of utmost importance that clinical microbiologists across India follow international guidelines and also take into account local settings, especially detection and presence of resistance enzymes. This article draws a framework for rational antimicrobial testing in our laboratories in tertiary care centers, from the Clinical and Laboratory Standards Institute guidelines. It does not address testing methodologies but suggests ways and means by which antimicrobial susceptibility reporting can be rendered meaningful not only to the treating physician but also to the resistance monitoring epidemiologist. It hopes to initiate some standardization in rational choice of antimicrobial testing in laboratories in the country pertaining to nonfastidious bacteria.

  12. 7. Exterior view of Components Test Laboratory (T27), looking south. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Exterior view of Components Test Laboratory (T-27), looking south. The wing in the immediate foreground houses the equipment room. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  13. Laboratory or Field Tests for Evaluating Firefighters' Work Capacity?

    PubMed Central

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = −0.81) and barbell shoulder press (rs = −0.77), for Pulling: IE shoulder extension (rs = −0.82) and bench press (rs = −0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = −0.83) and bench press (rs = −0.82), and for the Terrain work task: IE trunk flexion (rs = −0.58) and upright barbell row (rs = −0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity. PMID:24614596

  14. Laboratory or field tests for evaluating firefighters' work capacity?

    PubMed

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = -0.81) and barbell shoulder press (rs = -0.77), for Pulling: IE shoulder extension (rs = -0.82) and bench press (rs = -0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = -0.83) and bench press (rs = -0.82), and for the Terrain work task: IE trunk flexion (rs = -0.58) and upright barbell row (rs = -0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity.

  15. The role of laboratory in ensuring appropriate test requests.

    PubMed

    Ferraro, Simona; Panteghini, Mauro

    2017-07-01

    This review highlights the role of laboratory professionals and the strategies to be promoted in strict cooperation with clinicians for auditing, monitoring and improving the appropriateness of test request. The introduction of local pathways and care maps in agreement with international and national guidelines as well as the implementation of reflex testing and algorithms have a central role in guiding test request and in correcting the overuse/misuse of tests. Furthermore, removing obsolete tests from laboratory menu and vetting of restricted tests is recommended to increase cost-effectiveness. This saves costs and permits to introduce new biomarkers with increased diagnostic accuracy with a better impact on patient outcome. An additional issue is concerning the periodicity of (re)testing, accounting that only a minority of tests may be ordered as often as necessary. In the majority of cases, a minimum retesting interval should be introduced. The availability of effective computerised order entry systems is relevant in ensuring appropriate test requests and in providing an aid by automated rules that may stop inappropriate requests before they reach the laboratory. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Diagnosis of canine hypothyroidism. Perspectives from a testing laboratory.

    PubMed

    Kemppainen, R J; Behrend, E N

    2001-09-01

    The most common sample received by our endocrine testing laboratory is submitted for the diagnosis of hypothyroidism in a dog. The current tests most frequently employed in our laboratory for thyroid evaluation in dogs are total T4, free T4 by dialysis, and canine TSH measurement. Each test has strengths and weaknesses and suffers from the possibility of both false positive and false negative results. This article provides a working description of each test and an approach to interpretation of results. Other tests that are less commonly used are also discussed. Examples of interpretation of test results in individual hypothyroid-suspect dogs are presented for illustration.

  17. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  18. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  19. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  20. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  1. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  2. NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

    NASA Technical Reports Server (NTRS)

    Akers, James C.; Cooper, Beth A.

    2004-01-01

    NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive

  3. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  4. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  5. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  6. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  7. 7 CFR 3300.91 - List of approved testing stations, approved testing laboratories, and fees for certificates.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... testing stations, approved testing laboratories, and fees for certificates. A current list of U.S. ATP testing stations, U.S. ATP testing laboratories, and fees for issuance of U.S. ATP certificates may be...

  8. Financial incentives and the supply of laboratory tests.

    PubMed

    Carlsen, Fredrik; Grytten, Jostein; Skau, Irene

    2003-11-01

    This study examined how the number of laboratory tests taken by a sample of Norwegian contract physicians is influenced by their private economy outside of the practice and by changes in remuneration. The data are drawn from 40,000 consultations carried out by 44 contract physicians in 1991-1994. Two factors which led to changes in the level of physicians' income are considered: changes in remuneration for consultations and laboratory tests and changes in interest rates on loans and bank deposits. The effect which changes in interest rates have on physicians' disposable income was calculated using information about their financial assets and debts obtained from tax assessments. The main finding was that changes in private economy and changes in remuneration have no or only a small effect on the number of laboratory tests taken. Our results suggest that fee regulation can be an effective means of controlling physicians' income and therefore government expenditure on primary physician services.

  9. Eight year experience in open ended instrumentation laboratory

    NASA Astrophysics Data System (ADS)

    Marques, Manuel B.; Rosa, Carla C.; Marques, Paulo V. S.

    2015-10-01

    When designing laboratory courses in a Physics Major we consider a range of objectives: teaching Physics; developing lab competencies; instrument control and data acquisition; learning about measurement errors and error propagation; an introduction to project management; team work skills and scientific writing. But nowadays we face pressure to decrease laboratory hours due to the cost involved. Many universities are replacing lab classes for simulation activities, hiring PhD. and master students to give first year lab classes, and reducing lab hours. This leads to formatted lab scripts and poor autonomy of the students, and failure to enhance creativity and autonomy. In this paper we present our eight year experience with a laboratory course that is mandatory in the third year of Physics and Physical Engineering degrees. Since the students had previously two standard laboratory courses, we focused on teaching instrumentation and giving students autonomy. The course is divided in two parts: one third is dedicated to learn computer controlled instrumentation and data acquisition (based in LabView); the final 2/3 is dedicated to a group project. In this project, the team (2 or 3 students) must develop a project and present it in a typical conference format at the end of the semester. The project assignments are usually not very detailed (about two or three lines long), giving only general guidelines pointing to a successful project (students often recycle objectives putting forward a very personal project); all of them require assembling some hardware. Due to our background, about one third of the projects are related to Optics.

  10. Automated cognitive testing of monkeys in social groups yields results comparable to individual laboratory-based testing.

    PubMed

    Gazes, Regina Paxton; Brown, Emily Kathryn; Basile, Benjamin M; Hampton, Robert R

    2013-05-01

    Cognitive abilities likely evolved in response to specific environmental and social challenges and are therefore expected to be specialized for the life history of each species. Specialized cognitive abilities may be most readily engaged under conditions that approximate the natural environment of the species being studied. While naturalistic environments might therefore have advantages over laboratory settings for cognitive research, it is difficult to conduct certain types of cognitive tests in these settings. We implemented methods for automated cognitive testing of monkeys (Macaca mulatta) in large social groups (Field station) and compared the performance to that of laboratory-housed monkeys (Laboratory). The Field station animals shared access to four touch-screen computers in a large naturalistic social group. Each Field station subject had an RFID chip implanted in each arm for computerized identification and individualized assignment of cognitive tests. The Laboratory group was housed and tested in a typical laboratory setting, with individual access to testing computers in their home cages. Monkeys in both groups voluntarily participated at their own pace for food rewards. We evaluated performance in two visual psychophysics tests, a perceptual classification test, a transitive inference test, and a delayed matching-to-sample memory test. Despite the differences in housing, social environment, age, and sex, monkeys in the two groups performed similarly in all tests. Semi-free ranging monkeys living in complex social environments are therefore viable subjects for cognitive testing designed to take advantage of the unique affordances of naturalistic testing environments.

  11. Automated cognitive testing of monkeys in social groups yields results comparable to individual laboratory based testing

    PubMed Central

    Gazes, Regina Paxton; Brown, Emily Kathryn; Basile, Benjamin M.; Hampton, Robert R.

    2013-01-01

    Cognitive abilities likely evolved in response to specific environmental and social challenges and are therefore expected to be specialized for the life history of each species. Specialized cognitive abilities may be most readily engaged under conditions that approximate the natural environment of the species being studied. While naturalistic environments might therefore have advantages over laboratory settings for cognitive research, it is difficult to conduct certain types of cognitive tests in these settings. We implemented methods for automated cognitive testing of monkeys (Macaca mulatta) in large social groups (Field station) and compared the performance to that of laboratory housed monkeys (Laboratory). The Field station animals shared access to four touch screen computers in a large naturalistic social group. Each Field station subject had an RFID chip implanted in each arm for computerized identification and individualized assignment of cognitive tests. The Laboratory group was housed and tested in a typical laboratory setting, with individual access to testing computers in their home cages. Monkeys in both groups voluntarily participated at their own pace for food rewards. We evaluated performance in two visual psychophysics tests, a perceptual classification test, a transitive inference test, and a delayed matching to sample memory test. Despite differences in housing, social environment, age, and sex, monkeys in the two groups performed similarly in all tests. Semi-free ranging monkeys living in complex social environments are therefore viable subjects for cognitive testing designed to take advantage of the unique affordances of naturalistic testing environments. PMID:23263675

  12. 9 CFR 590.580 - Laboratory tests and analyses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Laboratory tests and analyses. 590.580 Section 590.580 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... sequence, frequency, and approved laboratory methods as prescribed by the AMS Science Division Director...

  13. 9 CFR 590.580 - Laboratory tests and analyses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Laboratory tests and analyses. 590.580 Section 590.580 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... sequence, frequency, and approved laboratory methods as prescribed by the AMS Science Division Director...

  14. 9 CFR 590.580 - Laboratory tests and analyses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Laboratory tests and analyses. 590.580 Section 590.580 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... sequence, frequency, and approved laboratory methods as prescribed by the AMS Science Division Director...

  15. First-year Engineering Education with the Creative Electrical Engineering Laboratory

    NASA Astrophysics Data System (ADS)

    Tsukamoto, Takehiko; Sugito, Tetsumasa; Ozeki, Osamu; Ushiroda, Sumio

    The Department of Electrical and Electronic Engineering in Toyota National College of Technology has put great emphasis on fundamental subjects. We introduced the creative electrical engineering laboratory into the first-year engineering education since 1998. The laboratory concentrates on the practice exercise. The final questionnaire of students showed that our first-year education is very effective to promote students motivation and their scholastic ability in engineering.

  16. Exploration of task performance tests in a physics laboratory

    NASA Astrophysics Data System (ADS)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  17. Hydrocephalus shunt technology: 20 years of experience from the Cambridge Shunt Evaluation Laboratory.

    PubMed

    Chari, Aswin; Czosnyka, Marek; Richards, Hugh K; Pickard, John D; Czosnyka, Zofia H

    2014-03-01

    The Cambridge Shunt Evaluation Laboratory was established 20 years ago. This paper summarizes the findings of that laboratory for the clinician. Twenty-six models of valves have been tested long-term in the shunt laboratory according to the expanded International Organization for Standardization 7197 standard protocol. The majority of the valves had a nonphysiologically low hydrodynamic resistance (from 1.5 to 3 mm Hg/[ml/min]), which may result in overdrainage related to posture and during nocturnal cerebral vasogenic waves. A long distal catheter increases the resistance of these valves by 100%-200%. Drainage through valves without a siphon-preventing mechanism is very sensitive to body posture, which may result in grossly negative intracranial pressure. Siphon-preventing accessories offer a reasonable resistance to negative outlet pressure; however, accessories with membrane devices may be blocked by raised subcutaneous pressure. In adjustable valves, the settings may be changed by external magnetic fields of intensity above 40 mT (exceptions: ProGAV, Polaris, and Certas). Most of the magnetically adjustable valves produce large distortions on MRI studies. The behavior of a valve revealed during testing is of relevance to the surgeon and may not be adequately described in the manufacturer's product information. The results of shunt testing are helpful in many circumstances, such as the initial choice of shunt and the evaluation of the shunt when its dysfunction is suspected.

  18. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  19. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  20. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  1. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  2. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  3. Trends in laboratory test volumes for Medicare Part B reimbursements, 2000-2010.

    PubMed

    Shahangian, Shahram; Alspach, Todd D; Astles, J Rex; Yesupriya, Ajay; Dettwyler, William K

    2014-02-01

    Changes in reimbursements for clinical laboratory testing may help us assess the effect of various variables, such as testing recommendations, market forces, changes in testing technology, and changes in clinical or laboratory practices, and provide information that can influence health care and public health policy decisions. To date, however, there has been no report, to our knowledge, of longitudinal trends in national laboratory test use. To evaluate Medicare Part B-reimbursed volumes of selected laboratory tests per 10,000 enrollees from 2000 through 2010. Laboratory test reimbursement volumes per 10,000 enrollees in Medicare Part B were obtained from the Centers for Medicare & Medicaid Services (Baltimore, Maryland). The ratio of the most recent (2010) reimbursed test volume per 10,000 Medicare enrollees, divided by the oldest data (usually 2000) during this decade, called the volume ratio, was used to measure trends in test reimbursement. Laboratory tests with a reimbursement claim frequency of at least 10 per 10,000 Medicare enrollees in 2010 were selected, provided there was more than a 50% change in test reimbursement volume during the 2000-2010 decade. We combined the reimbursed test volumes for the few tests that were listed under more than one code in the Current Procedural Terminology (American Medical Association, Chicago, Illinois). A 2-sided Poisson regression, adjusted for potential overdispersion, was used to determine P values for the trend; trends were considered significant at P < .05. Tests with the greatest decrease in reimbursement volumes were electrolytes, digoxin, carbamazepine, phenytoin, and lithium, with volume ratios ranging from 0.27 to 0.64 (P < .001). Tests with the greatest increase in reimbursement volumes were meprobamate, opiates, methadone, phencyclidine, amphetamines, cocaine, and vitamin D, with volume ratios ranging from 83 to 1510 (P < .001). Although reimbursement volumes increased for most of the selected tests, other

  4. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    PubMed

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn

  5. Laboratory Testing Protocols for Heparin-Induced Thrombocytopenia (HIT) Testing.

    PubMed

    Lau, Kun Kan Edwin; Mohammed, Soma; Pasalic, Leonardo; Favaloro, Emmanuel J

    2017-01-01

    Heparin-induced thrombocytopenia (HIT) represents a significant high morbidity complication of heparin therapy. The clinicopathological diagnosis of HIT remains challenging for many reasons; thus, laboratory testing represents an important component of an accurate diagnosis. Although there are many assays available to assess HIT, these essentially fall into two categories-(a) immunological assays, and (b) functional assays. The current chapter presents protocols for several HIT assays, being those that are most commonly performed in laboratory practice and have the widest geographic distribution. These comprise a manual lateral flow-based system (STiC), a fully automated latex immunoturbidimetric assay, a fully automated chemiluminescent assay (CLIA), light transmission aggregation (LTA), and whole blood aggregation (Multiplate).

  6. Constrained Laboratory vs. Unconstrained Steering-Induced Rollover Crash Tests.

    PubMed

    Kerrigan, Jason R; Toczyski, Jacek; Roberts, Carolyn; Zhang, Qi; Clauser, Mark

    2015-01-01

    The goal of this study was to evaluate how well an in-laboratory rollover crash test methodology that constrains vehicle motion can reproduce the dynamics of unconstrained full-scale steering-induced rollover crash tests in sand. Data from previously-published unconstrained steering-induced rollover crash tests using a full-size pickup and mid-sized sedan were analyzed to determine vehicle-to-ground impact conditions and kinematic response of the vehicles throughout the tests. Then, a pair of replicate vehicles were prepared to match the inertial properties of the steering-induced test vehicles and configured to record dynamic roof structure deformations and kinematic response. Both vehicles experienced greater increases in roll-axis angular velocities in the unconstrained tests than in the constrained tests; however, the increases that occurred during the trailing side roof interaction were nearly identical between tests for both vehicles. Both vehicles experienced linear accelerations in the constrained tests that were similar to those in the unconstrained tests, but the pickup, in particular, had accelerations that were matched in magnitude, timing, and duration very closely between the two test types. Deformations in the truck test were higher in the constrained than the unconstrained, and deformations in the sedan were greater in the unconstrained than the constrained as a result of constraints of the test fixture, and differences in impact velocity for the trailing side. The results of the current study suggest that in-laboratory rollover tests can be used to simulate the injury-causing portions of unconstrained rollover crashes. To date, such a demonstration has not yet been published in the open literature. This study did, however, show that road surface can affect vehicle response in a way that may not be able to be mimicked in the laboratory. Lastly, this study showed that configuring the in-laboratory tests to match the leading-side touchdown conditions

  7. Good Laboratory Practices of Materials Testing at NASA White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Hirsch, David; Williams, James H.

    2005-01-01

    An approach to good laboratory practices of materials testing at NASA White Sands Test Facility is presented. The contents include: 1) Current approach; 2) Data analysis; and 3) Improvements sought by WSTF to enhance the diagnostic capability of existing methods.

  8. 42 CFR 493.1421 - Condition: Laboratories performing moderate complexity testing; testing personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate complexity testing; testing personnel. 493.1421 Section 493.1421 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  9. 42 CFR 493.1421 - Condition: Laboratories performing moderate complexity testing; testing personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing moderate complexity testing; testing personnel. 493.1421 Section 493.1421 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  10. 7 CFR 75.43 - Laboratory testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Laboratory testing. 75.43 Section 75.43 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 AND THE...

  11. Mars Science Laboratory Workstation Test Set

    NASA Technical Reports Server (NTRS)

    Henriquez, David A.; Canham, Timothy K.; Chang, Johnny T.; Villaume, Nathaniel

    2009-01-01

    The Mars Science Laboratory developed the Workstation TestSet (WSTS) is a computer program that enables flight software development on virtual MSL avionics. The WSTS is the non-real-time flight avionics simulator that is designed to be completely software-based and run on a workstation class Linux PC.

  12. 1. Exterior view of Components Test Laboratory (T27), looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Exterior view of Components Test Laboratory (T-27), looking southeast from hill north of structure. The building wing in the right foreground houses Test Cell 8 (oxidizer) and the oxidizer storage pit or vault. Test Cell 10 is located in the center background, Test Cell 9 is at the far left, and the equipment room is in the immediate left foreground. The control room is in the center of the structure and abuts the aforementioned test cell and equipment room wings. This structure served as a facility for testing, handling, and storage of Titan II's hydrazine- and nitrogen teteroxide-based propellant system components for compatability determinations. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  13. Nondestructive Testing and Evaluation of Wood—50 Years of Research: International Nondestructive Testing and Evaluation of Wood Symposium Series

    Treesearch

    Robert J. Ross; Xiping Wang

    2012-01-01

    The International Nondestructive Testing and Evaluation of Wood Symposium Series was initiated by Washington State University and the USDA Forest Products Laboratory (FPL) in 1963 with the convening of a symposium on the topic of nondestructive testing of wood at FPL. Including that meeting, 17 symposia have been held during the last 50 years at various sites around...

  14. Laboratory testing of alcohol safety interlock systems employing divided attention tests

    DOT National Transportation Integrated Search

    1975-12-01

    Author's abstract: Prototype Alcohol Safety Interlock Systems employing measurements of tracking ability, reaction time, and response accuracy to discern alcohol impairment were submitted to laboratory testing. These systems were modified versions of...

  15. Electronics systems test laboratory testing of shuttle communications systems

    NASA Technical Reports Server (NTRS)

    Stoker, C. J.; Bromley, L. K.

    1985-01-01

    Shuttle communications and tracking systems space to space and space to ground compatibility and performance evaluations are conducted in the NASA Johnson Space Center Electronics Systems Test Laboratory (ESTL). This evaluation is accomplished through systems verification/certification tests using orbiter communications hardware in conjunction with other shuttle communications and tracking external elements to evaluate end to end system compatibility and to verify/certify that overall system performance meets program requirements before manned flight usage. In this role, the ESTL serves as a multielement major ground test facility. The ESTL capability and program concept are discussed. The system test philosophy for the complex communications channels is described in terms of the major phases. Results of space to space and space to ground systems tests are presented. Several examples of the ESTL's unique capabilities to locate and help resolve potential problems are discussed in detail.

  16. Long-term pavement performance project laboratory materials testing and handling guide

    DOT National Transportation Integrated Search

    2007-09-01

    The Long Term Pavement Performance (LTPP) Laboratory Material Testing Guide was originally prepared for laboratory material handling and testing of material specimens and samples of asphalt materials, portland cement concrete, aggregates, and soils u...

  17. Impact of external haematology proficiency testing programme on quality of laboratories.

    PubMed

    Saxena, Renu; Katoch, S C; Srinivas, Upendra; Rao, Seema; Anand, Hema

    2007-11-01

    A reliable and reproducible report from a laboratory needs internal quality control within the laboratory and participation in external proficiency testing programmes (EPTP). This study conducted at the Department of Haematology, All India Institute of Medical Sciences (AIIMS), New Delhi, which has been conducting an EPTP since 1992, was undertaken to assess the efficacy of this programme in improving the performance of participating laboratories in reporting test samples sent for Hb, total leucocyte count (TLC), reticulocyte count and assessment of peripheral blood smear (PBS). The samples were prepared in our laboratory according to the International Standards Organization (ISO) guidelines. The performance of individual laboratories was assessed using robust Z score, which is an indicator of acceptability of the test result. An improvement in the overall percentage of laboratories with acceptable reports was seen during the study period. It has increased from 38,40,40 per cent in 1992 to 85, 90,94.7 per cent in 2006 for Hb, TLC, reticulocyte count, respectively. However, the results for peripheral smear assessment improved only marginally. The external haematology proficiency testing programme run by our department for Hb, TLC, reticulocyte count, and peripheral blood smear assessment, has helped in improving the reporting standards of these parameters in Indian laboratories.

  18. The Mars Science Laboratory Touchdown Test Facility

    NASA Technical Reports Server (NTRS)

    White, Christopher; Frankovich, John; Yates, Phillip; Wells Jr, George H.; Losey, Robert

    2009-01-01

    In the Touchdown Test Program for the Mars Science Laboratory (MSL) mission, a facility was developed to use a full-scale rover vehicle and an overhead winch system to replicate the Skycrane landing event.

  19. Mars Science Laboratory Spacecraft Assembled for Testing

    NASA Image and Video Library

    2008-11-19

    The major components of NASA Mars Science Laboratory spacecraft -- cruise stage atop the aeroshell, which has the descent stage and rover inside -- were connected together in October 2008 for several weeks of system testing.

  20. 24th geotechnical laboratory testing short course

    DOT National Transportation Integrated Search

    2008-02-01

    This is a 3-day workshop/short course to teach practicing professionals techniques and procedures for conducting high quality geotechnical laboratory tests. Transportation facility design and construction begins with an investigation of the type, ext...

  1. 9. Exterior view, Test Cell 7, Systems Integration Laboratory Building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Exterior view, Test Cell 7, Systems Integration Laboratory Building (T-28), looking southwest. The enclosure discussed in CO-88-B-8 is at the right. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  2. Approaches to quality management and accreditation in a genetic testing laboratory

    PubMed Central

    Berwouts, Sarah; Morris, Michael A; Dequeker, Elisabeth

    2010-01-01

    Medical laboratories, and specifically genetic testing laboratories, provide vital medical services to different clients: clinicians requesting a test, patients from whom the sample was collected, public health and medical-legal instances, referral laboratories and authoritative bodies. All expect results that are accurate and obtained in an efficient and effective manner, within a suitable time frame and at acceptable cost. There are different ways of achieving the end results, but compliance with International Organization for Standardization (ISO) 15189, the international standard for the accreditation of medical laboratories, is becoming progressively accepted as the optimal approach to assuring quality in medical testing. We present recommendations and strategies designed to aid genetic testing laboratories with the implementation of a quality management system, including key aspects such as document control, external quality assessment, internal quality control, internal audit, management review, validation, as well as managing the human side of change. The focus is on pragmatic approaches to attain the levels of quality management and quality assurance required for accreditation according to ISO 15189, within the context of genetic testing. Attention is also given to implementing efficient and effective quality improvement. PMID:20720559

  3. Quality assurance practices in Europe: a survey of molecular genetic testing laboratories

    PubMed Central

    Berwouts, Sarah; Fanning, Katrina; Morris, Michael A; Barton, David E; Dequeker, Elisabeth

    2012-01-01

    In the 2000s, a number of initiatives were taken internationally to improve quality in genetic testing services. To contribute to and update the limited literature available related to this topic, we surveyed 910 human molecular genetic testing laboratories, of which 291 (32%) from 29 European countries responded. The majority of laboratories were in the public sector (81%), affiliated with a university hospital (60%). Only a minority of laboratories was accredited (23%), and 26% was certified. A total of 22% of laboratories did not participate in external quality assessment (EQA) and 28% did not use reference materials (RMs). The main motivations given for accreditation were to improve laboratory profile (85%) and national recognition (84%). Nearly all respondents (95%) would prefer working in an accredited laboratory. In accredited laboratories, participation in EQA (P<0.0001), use of RMs (P=0.0014) and availability of continuous education (CE) on medical/scientific subjects (P=0.023), specific tasks (P=0.0018), and quality assurance (P<0.0001) were significantly higher than in non-accredited laboratories. Non-accredited laboratories expect higher restriction of development of new techniques (P=0.023) and improvement of work satisfaction (P=0.0002) than accredited laboratories. By using a quality implementation score (QIS), we showed that accredited laboratories (average score 92) comply better than certified laboratories (average score 69, P<0.001), and certified laboratories better than other laboratories (average score 44, P<0.001), with regard to the implementation of quality indicators. We conclude that quality practices vary widely in European genetic testing laboratories. This leads to a potentially dangerous situation in which the quality of genetic testing is not consistently assured. PMID:22739339

  4. 6. Exterior view of Components Test Laboratory (T27), looking southwest. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Exterior view of Components Test Laboratory (T-27), looking southwest. The building wing on the left houses Test Cell 9 (fuel), and that on the right houses the equipment room. The corrugated aluminum shed that is taller than the main building in the left foreground houses a citric acid air pollution control room (also known as scrubber room), the interior of which may be seen in CO-88-A-21. - Air Force Plant PJKS, Systems Integration Laboratory, Components Test Laboratory, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  5. Hydrogen Field Test Standard: Laboratory and Field Performance

    PubMed Central

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors < 0.1 % and < 0.04 % in the PVT and master meter methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give

  6. Workgroup for Hydraulic laboratory Testing and Verification of Hydroacoustic Instrumentation

    USGS Publications Warehouse

    Fulford, Janice M.; Armstrong, Brandy N.; Thibodeaux, Kirk G.

    2015-01-01

    An international workgroup was recently formed for hydraulic laboratory testing and verification of hydroacoustic instrumentation used for water velocity measurements. The activities of the workgroup have included one face to face meeting, conference calls and an inter-laboratory exchange of two acoustic meters among participating laboratories. Good agreement was found among four laboratories at higher tow speeds and poorer agreement at the lowest tow speed.

  7. Laboratory testing of gross solids removal devices.

    DOT National Transportation Integrated Search

    2005-05-01

    This report details the outcome of tests carried out at the Hydraulics Laboratory : of the University of California, Davis to assess the performance of three : alternative Gross Solids Removal Devices (GSRDs) developed by Caltrans to : remove litter ...

  8. LABORATORY TOXICITY TESTS FOR EVALUATING POTENTIAL EFFECTS OF ENDOCRINE-DISRUPTING COMPOUNDS

    EPA Science Inventory

    The scope of the Laboratory Testing Work Group was to evaluate methods for testing aquatic and terrestrial invertebrates in the laboratory. Specifically, discussions focused on the following objectives: 1) assess the extent to which consensus-based standard methods and other pub...

  9. Quality-assurance results for routine water analyses in U.S. Geological Survey laboratories, water year 1998

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.

    2000-01-01

    (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).

  10. Indications for laboratory tests in primary care: assessment of the most frequent indications and requests with blank clinical information

    PubMed Central

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Leiva-Salinas, Maria; Esteban, Patricia; Ahumada, Miguel; Leiva-Salinas, Carlos

    2016-01-01

    Introduction The aim of this work is twofold. Firstly, to study the temporal evolution in the number of laboratory requests from primary care without clinical indication, and to analyse the number of such requests before and after the implementation of an automated requesting procedure. Secondly, to investigate what are the most frequent clinical indications that prompted laboratory testing. Materials and methods This is a retrospective observational study conducted from January 2009 to December 2015. We counted the requests without clinical question, calculated the number of such requests per total number of requests and listed the most frequent indications. Results The number of tests requests with a blank clinical indication was significantly higher in 2009 when compared to 2015 (80% vs. 20%; P < 0.001). For every year in this 7-year period, dyslipidemia, essential hypertension and diabetes were the most prevalent diagnoses that prompted a laboratory test in primary care, accounting for more than 20% of all indications. Conclusions The number of primary care requests without patient clinical question has decreased after the implementation of an automated requesting procedure. Disorders of lipid metabolism, essential hypertension and diabetes mellitus were the most prevalent diagnoses that prompted a laboratory test in primary care. PMID:27812310

  11. 2000-hour cyclic endurance test of a laboratory model multipropellant resistojet

    NASA Technical Reports Server (NTRS)

    Morren, W. Earl; Sovey, James S.

    1987-01-01

    The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.

  12. The testing effect for mediator final test cues and related final test cues in online and laboratory experiments.

    PubMed

    Coppens, Leonora C; Verkoeijen, Peter P J L; Bouwmeester, Samantha; Rikers, Remy M J P

    2016-05-31

    The testing effect is the finding that information that is retrieved during learning is more often correctly retrieved on a final test than information that is restudied. According to the semantic mediator hypothesis the testing effect arises because retrieval practice of cue-target pairs (mother-child) activates semantically related mediators (father) more than restudying. Hence, the mediator-target (father-child) association should be stronger for retrieved than restudied pairs. Indeed, Carpenter (2011) found a larger testing effect when participants received mediators (father) than when they received target-related words (birth) as final test cues. The present study started as an attempt to test an alternative account of Carpenter's results. However, it turned into a series of conceptual (Experiment 1) and direct (Experiment 2 and 3) replications conducted with online samples. The results of these online replications were compared with those of similar existing laboratory experiments through small-scale meta-analyses. The results showed that (1) the magnitude of the raw mediator testing effect advantage is comparable for online and laboratory experiments, (2) in both online and laboratory experiments the magnitude of the raw mediator testing effect advantage is smaller than in Carpenter's original experiment, and (3) the testing effect for related cues varies considerably between online experiments. The variability in the testing effect for related cues in online experiments could point toward moderators of the related cue short-term testing effect. The raw mediator testing effect advantage is smaller than in Carpenter's original experiment.

  13. Advanced Materials Laboratory User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Orndoff, Evelyne

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the Advanced Materials Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  14. 19 CFR 151.54 - Testing by Customs laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 2 2014-04-01 2014-04-01 false Testing by Customs laboratory. 151.54 Section 151.54 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Metal-Bearing Ores and...

  15. 19 CFR 151.54 - Testing by Customs laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 2 2011-04-01 2011-04-01 false Testing by Customs laboratory. 151.54 Section 151.54 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Metal-Bearing Ores and...

  16. 19 CFR 151.54 - Testing by Customs laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 2 2013-04-01 2013-04-01 false Testing by Customs laboratory. 151.54 Section 151.54 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Metal-Bearing Ores and...

  17. ISO 15189 accreditation: Requirements for quality and competence of medical laboratories, experience of a laboratory I.

    PubMed

    Guzel, Omer; Guner, Ebru Ilhan

    2009-03-01

    Medical laboratories are the key partners in patient safety. Laboratory results influence 70% of medical diagnoses. Quality of laboratory service is the major factor which directly affects the quality of health care. The clinical laboratory as a whole has to provide the best patient care promoting excellence. International Standard ISO 15189, based upon ISO 17025 and ISO 9001 standards, provides requirements for competence and quality of medical laboratories. Accredited medical laboratories enhance credibility and competency of their testing services. Our group of laboratories, one of the leading institutions in the area, had previous experience with ISO 9001 and ISO 17025 Accreditation at non-medical sections. We started to prepared for ISO 15189 Accreditation at the beginning of 2006 and were certified in March, 2007. We spent more than a year to prepare for accreditation. Accreditation scopes of our laboratory were as follows: clinical chemistry, hematology, immunology, allergology, microbiology, parasitology, molecular biology of infection serology and transfusion medicine. The total number of accredited tests is 531. We participate in five different PT programs. Inter Laboratory Comparison (ILC) protocols are performed with reputable laboratories. 82 different PT Program modules, 277 cycles per year for 451 tests and 72 ILC program organizations for remaining tests have been performed. Our laboratory also organizes a PT program for flow cytometry. 22 laboratories participate in this program, 2 cycles per year. Our laboratory has had its own custom made WEB based LIS system since 2001. We serve more than 500 customers on a real time basis. Our quality management system is also documented and processed electronically, Document Management System (DMS), via our intranet. Preparatory phase for accreditation, data management, external quality control programs, personnel related issues before, during and after accreditation process are presented. Every laboratory has

  18. Feasibility study of an orbiting laboratory for testing CSI technology

    NASA Technical Reports Server (NTRS)

    Bicos, Andrew S.; Loboda, Gregory G.

    1993-01-01

    A concept for an orbiting laboratory for testing Controls-Structures Integration (CSI) technology is described. The CSI-Star concept reflects a lower cost, higher risk approach. The concept supports demonstration and validation testing for critical CSI technologies at a cost of $20M to $26M with a 1-year reliability of approximately 0.9. The Ball Aerospace QuickStar bus is the carrier for the CSI test article. QuickStar is launched as a secondary payload on the McDonnell Douglas Delta 2. The QuickStar/Delta 2 approach is flight proven. The CSI test article is a 20 foot, 1 Hz, truss beam which is deployed from the QuickStar bus. The test article is well instrumented for quality system identification. The laboratory provides three layers of active control consisting of global vibration suppression along the truss beam, vibration isolation between the beam and instrument platforms, and vibration compensation through the use of gimbaled platforms which point lasers relative to optical sensor targets. The configuration simulates the dynamics of multi-instrument science platforms such as those of the Earth Observation System (EOS) while maintaining strong ties to astrophysics missions such as the Optical Interferometer. Uplink/downlink services and a reprogrammable computer provide flexibility for long-term investigations by members of the CSI community (NASA, DoD, academia, and industry). CSI-Star fills the gap between short-term experiments, which have been conducted primarily on the Shuttle, and future science missions which require the technology. The on-orbit maturity of CSI technology must be established to obtain acceptance by project managers and to promote injection of the technology into future science missions.

  19. Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Broerman, Craig; Jimenez, Javier; Sweterlitsch, Jeff

    2012-01-01

    The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory.

  20. Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Broerman, Craig; Jimenez, Javier; Sweterlitsch, Jeff

    2011-01-01

    The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory

  1. Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females

    PubMed Central

    Ryden, Ingvar; Lind, Lars

    2012-01-01

    Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333

  2. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    PubMed

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  3. A 50-year research journey. From laboratory to clinic.

    PubMed

    Ross, John

    2009-01-01

    Prior important research is not always cited, exemplified by Oswald Avery's pioneering discovery that DNA is the genetic transforming factor; it was not cited by Watson and Crick 10 years later. My first laboratory research (National Institutes of Health 1950s) resulted in the clinical development of transseptal left heart catheterization. Laboratory studies on cardiac muscle mechanics in normal and failing hearts led to the concept of afterload mismatch with limited preload reserve. At the University of California, San Diego in La Jolla (1968) laboratory experiments on coronary artery reperfusion after sustained coronary occlusion showed salvage of myocardial tissue, a potential treatment for acute myocardial infarction proven in clinical trials of thrombolysis 14 years later. Among 60 trainees who worked with me in La Jolla, one-third were Japanese and some of their important laboratory experiments are briefly recounted, beginning with Sasayama, Tomoike and Shirato in the 1970 s. Recently, we developed a method for cardiac gene transfer, and subsequently we showed that gene therapy for the defect in cardiomyopathic hamsters halted the progression of advanced disease. Cardiovascular research and medicine are producing continuing advances in technologies for gene transfer and embryonic stem cell transplantation, targeting of small molecules, and tissue and organ engineering.

  4. Familiarisation and Reliability of Sprint Test Indices During Laboratory and Field Assessment

    PubMed Central

    Hopker, James G.; Coleman, Damian A.; Wiles, Jonathan D.; Galbraith, Andrew

    2009-01-01

    The aim of the study was to assess the reliability of sprint performance in both field and laboratory conditions. Twenty-one male (mean ± s: 19 ± 1 years, 1.79 ± 0.07 m, 77.6 ± 7.1 kg) and seventeen female team sport players (mean ± s: 21 ± 4 years, 1.68 ± 0. 07 m, 62.7 ± 4.7 kg) performed a maximal 20-metre sprint running test on eight separate occasions. Four trials were conducted on a non-motorised treadmill in the laboratory; the other four were conducted outdoors on a hard-court training surface with time recorded by single-beam photocells. Trials were conducted in random order with no familiarisation prior to testing. There was a significant difference between times recorded during outdoor field trials (OFT) and indoor laboratory trials (ILT) using a non-motorised treadmill (3.47 ± 0.53 vs. 6.06 ±1.17s; p < 0.001). The coefficient of variation (CV) for time was 2.55-4.22% for OFT and 5.1-7.2% for ILT. During ILT peak force (420.9 ± 87.7N), mean force (147.2 ± 24.7N), peak power (1376.8 ± 451.9W) and mean power (514.8 ± 164.4W), and were measured. The CV for all ILT variables was highest during trial 1-2 comparison. The CV (95% confidence interval) for the trial 3-4 comparison yielded: 9.4% (7.7-12. 1%), 7.9% (6.4-10.2%), 10.1% (8.2-13.1%) and 6.2% (5.1-8.0%) for PF, MF, PP and MP and respectively. The results indicate that reliable data can be derived for single maximal sprint measures, using fixed distance protocols. However, significant differences in time/speed over 20-m exist between field and laboratory conditions. This is primarily due to the frictional resistance in the non- motorised treadmill. Measures of force and power during ILT require at least 3 familiarisations to reduce variability in test scores. Key points Reliable data can be derived from single maximal sprint measures in both indoor and outdoor environments using fixed distance protocols. There may be significant time differences to complete fixed distance trials between the

  5. Corrections of clinical chemistry test results in a laboratory information system.

    PubMed

    Wang, Sihe; Ho, Virginia

    2004-08-01

    The recently released reports by the Institute of Medicine, To Err Is Human and Patient Safety, have received national attention because of their focus on the problem of medical errors. Although a small number of studies have reported on errors in general clinical laboratories, there are, to our knowledge, no reported studies that focus on errors in pediatric clinical laboratory testing. To characterize the errors that have caused corrections to have to be made in pediatric clinical chemistry results in the laboratory information system, Misys. To provide initial data on the errors detected in pediatric clinical chemistry laboratories in order to improve patient safety in pediatric health care. All clinical chemistry staff members were informed of the study and were requested to report in writing when a correction was made in the laboratory information system, Misys. Errors were detected either by the clinicians (the results did not fit the patients' clinical conditions) or by the laboratory technologists (the results were double-checked, and the worksheets were carefully examined twice a day). No incident that was discovered before or during the final validation was included. On each Monday of the study, we generated a report from Misys that listed all of the corrections made during the previous week. We then categorized the corrections according to the types and stages of the incidents that led to the corrections. A total of 187 incidents were detected during the 10-month study, representing a 0.26% error detection rate per requisition. The distribution of the detected incidents included 31 (17%) preanalytic incidents, 46 (25%) analytic incidents, and 110 (59%) postanalytic incidents. The errors related to noninterfaced tests accounted for 50% of the total incidents and for 37% of the affected tests and orderable panels, while the noninterfaced tests and panels accounted for 17% of the total test volume in our laboratory. This pilot study provided the rate and

  6. Laboratory test results for an airborne ASTER simulator

    NASA Astrophysics Data System (ADS)

    Ezaka, Teruya; Kannari, Yoshiaki; Mills, Franklin P.; Watanabe, Hiroshi; Sano, Masaharu; Chang, Sheng-Huei

    1993-08-01

    An airborne ASTER simulator (AAS) is being developed by the Geophysical Environmental Research Corporation (GER) to study land surface temperature and emittance in the thermal infrared. Laboratory tests in October 1992 at NASA's Stennis Space Center (SSC) measured the AAS's spectral, approximate NEdT, and approximate spatial response characteristics. The spectral FWHM for most channels is smaller than 0.3 micrometers ; the NEdT for most TIR channels is better than 0.4 K; and the nominal IFOV is 5 mrad. Flight data was collected over Cuprite and Goldfield, Nevada and near Valencia, California in November 1992. The silicified and opalized zones at Cuprite could be discriminated using decorrelation-stretch images. AAS decorrelation-stretch images agree, qualitatively, with data from NASA's thermal infrared mapping spectrometer (TIMS). These results indicate the AAS may be a good tool for remote sensing studies of geological materials. Lower noise detector arrays and linear variable (optical) filters for the TIR channels will be tested in flights over Cuprite, Nevada later this year. These and other improvements may reduce the NEdT and improve the signal-to-noise ratio.

  7. CAP/ACMG proficiency testing for biochemical genetics laboratories: a summary of performance.

    PubMed

    Oglesbee, Devin; Cowan, Tina M; Pasquali, Marzia; Wood, Timothy C; Weck, Karen E; Long, Thomas; Palomaki, Glenn E

    2018-01-01

    PurposeTesting for inborn errors of metabolism is performed by clinical laboratories worldwide, each utilizing laboratory-developed procedures. We sought to summarize performance in the College of American Pathologists' (CAP) proficiency testing (PT) program and identify opportunities for improving laboratory quality. When evaluating PT data, we focused on a subset of laboratories that have participated in at least one survey since 2010.MethodsAn analysis of laboratory performance (2004 to 2014) on the Biochemical Genetics PT Surveys, a program administered by CAP and the American College of Medical Genetics and Genomics. Analytical and interpretive performance was evaluated for four tests: amino acids, organic acids, acylcarnitines, and mucopolysaccharides.ResultsSince 2010, 150 laboratories have participated in at least one of four PT surveys. Analytic sensitivities ranged from 88.2 to 93.4%, while clinical sensitivities ranged from 82.4 to 91.0%. Performance was higher for US participants and for more recent challenges. Performance was lower for challenges with subtle findings or complex analytical patterns.ConclusionUS clinical biochemical genetics laboratory proficiency is satisfactory, with a minority of laboratories accounting for the majority of errors. Our findings underscore the complex nature of clinical biochemical genetics testing and highlight the necessity of continuous quality management.

  8. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  9. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  10. Improvement of coagulation laboratory practice in Thailand: the first-year experience of the national external quality assessment scheme for blood coagulation.

    PubMed

    Tientadakul, Panutsaya; Opartkiattikul, Nisarat; Wongtiraporn, Wanida

    2009-01-01

    In Thailand until 2005 there had been no external quality assessment scheme at the national level for blood coagulation tests. Only a few laboratories had an external quality assessment for these tests. In the year 2005, the Thailand National External Quality Assessment Scheme for Blood Coagulation was founded. To describe the establishment of the Thailand National External Quality Assessment Scheme for Blood Coagulation (including problems encountered and solutions), its progression and expansion, and the improvement of coagulation laboratory practice in Thailand during 2 trial surveys and 4 formal surveys conducted in the first 1 1/2 years. Between 2005 and 2006, the external quality assessment samples for prothrombin time/international normalized ratio and activated partial thromboplastin time were distributed to the participants as well as the instructions and suggestions for the improvement of laboratory practice. From the data collected, the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time was calculated for each survey. The number of participants increased during the first 1 1/2 years that the surveys were conducted, from 109 to 127. Survey data demonstrate an improvement in response rate and an increase in the number of laboratories that determine their own reference ranges and repeat this for every change of reagent lot, using the appropriate anticoagulant. The increased precision of tests is indicated by the decrease of the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time. Examples of individual laboratory improvement through feedback are also described. The improvement of coagulation laboratory practice both through the instructions provided and liaison with participants was observed during the course of this scheme.

  11. Laboratory Testing of Waste Isolation Pilot Plant Surrogate Waste Materials

    NASA Astrophysics Data System (ADS)

    Broome, S.; Bronowski, D.; Pfeifle, T.; Herrick, C. G.

    2011-12-01

    The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy geological repository for the permanent disposal of defense-related transuranic (TRU) waste. The waste is emplaced in rooms excavated in the bedded Salado salt formation at a depth of 655 m below the ground surface. After emplacement of the waste, the repository will be sealed and decommissioned. WIPP Performance Assessment modeling of the underground material response requires a full and accurate understanding of coupled mechanical, hydrological, and geochemical processes and how they evolve with time. This study was part of a broader test program focused on room closure, specifically the compaction behavior of waste and the constitutive relations to model this behavior. The goal of this study was to develop an improved waste constitutive model. The model parameters are developed based on a well designed set of test data. The constitutive model will then be used to realistically model evolution of the underground and to better understand the impacts on repository performance. The present study results are focused on laboratory testing of surrogate waste materials. The surrogate wastes correspond to a conservative estimate of the degraded containers and TRU waste materials after the 10,000 year regulatory period. Testing consists of hydrostatic, uniaxial, and triaxial tests performed on surrogate waste recipes that were previously developed by Hansen et al. (1997). These recipes can be divided into materials that simulate 50% and 100% degraded waste by weight. The percent degradation indicates the anticipated amount of iron corrosion, as well as the decomposition of cellulosics, plastics, and rubbers. Axial, lateral, and volumetric strain and axial and lateral stress measurements were made. Two unique testing techniques were developed during the course of the experimental program. The first involves the use of dilatometry to measure sample volumetric strain under a hydrostatic condition. Bulk

  12. Frederick National Laboratory Celebrates 40 Years | Poster

    Cancer.gov

    By Ashley DeVine, Staff Writer Forty years ago, what we now call the Frederick National Laboratory for Cancer Research was born. Here are some highlights in the facility’s history. October 19, 1971 – President Richard Nixon announced that Fort Detrick would be converted from a biological warfare facility to a cancer research center (Covert, Norman M., Cutting Edge: A History

  13. Access to laboratory testing: the impact of managed care in the Pacific Northwest.

    PubMed

    LaBeau, K M; Simon, M; Steindel, S J

    1999-01-01

    Patient access to health-care services has become an important issue owing to the growth of managed care organizations and the number of patients enrolled. To better understand the current issues related to access to laboratory testing, with a particular focus on the impact of managed care, we gathered information from a network of clinical laboratories in the Pacific Northwest. Two questionnaires were sent to the 257 Laboratory Medicine Sentinel Monitoring Network participants in November 1995 and March 1996 to investigate trends in the availability and utilization of laboratory testing services and changes in onsite testing menus. Although laboratories reported that managed care was a factor in their decisions about laboratory practices, testing decisions were more likely made for business reasons, based on medical practice changes and marketplace influences not associated with managed care.

  14. In-flight and laboratory vacuum-friction test results

    NASA Technical Reports Server (NTRS)

    Devine, E. J.; Evans, H. E.; Leasure, W. A.

    1973-01-01

    Coefficient of friction measurements were made for six unlubricated metal couples exposed to the space environment aboard the OV-1-13 spacecraft and exposed to laboratory vacuum. Materials studied included mutually soluble, partially soluble, and insoluble metal combinations. Two samples of each material couple were tested in space and in the laboratory using the disk and rider technique. Linear velocity was 0.10 cm/s (2.5 in/min) and rider normal load was 4.45 N (1 lb) for the gold versus silver couples and 8.90 N (2lb) for the other combinations. Results showed that friction data obtained in a clean ion-pumped laboratory vacuum of 10 to the minus 10 power materials with low mutual solubility can be correlated to operation in the vicinity of a typical scientific spacecraft that is exposed to an ambient pressure as low as 10 to the minus 12 power torr. The expected increase in coefficient of friction with solubility was shown. Material couples with high mutual solubility present the hazard of unpredictable drastic friction increase in orbit which may not be evident in laboratory testing at levels down to 10 to the minus 10 power torr. It was also shown that gross cold welding of unlubricated metals exposed to a satellite environment does not occur.

  15. Mars Science Laboratory Rover System Thermal Test

    NASA Technical Reports Server (NTRS)

    Novak, Keith S.; Kempenaar, Joshua E.; Liu, Yuanming; Bhandari, Pradeep; Dudik, Brenda A.

    2012-01-01

    On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. The MSL rover is scheduled to land on Mars on August 5, 2012. Prior to launch, the Rover was successfully operated in simulated mission extreme environments during a 16-day long Rover System Thermal Test (STT). This paper describes the MSL Rover STT, test planning, test execution, test results, thermal model correlation and flight predictions. The rover was tested in the JPL 25-Foot Diameter Space Simulator Facility at the Jet Propulsion Laboratory (JPL). The Rover operated in simulated Cruise (vacuum) and Mars Surface environments (8 Torr nitrogen gas) with mission extreme hot and cold boundary conditions. A Xenon lamp solar simulator was used to impose simulated solar loads on the rover during a bounding hot case and during a simulated Mars diurnal test case. All thermal hardware was exercised and performed nominally. The Rover Heat Rejection System, a liquid-phase fluid loop used to transport heat in and out of the electronics boxes inside the rover chassis, performed better than predicted. Steady state and transient data were collected to allow correlation of analytical thermal models. These thermal models were subsequently used to predict rover thermal performance for the MSL Gale Crater landing site. Models predict that critical hardware temperatures will be maintained within allowable flight limits over the entire 669 Sol surface mission.

  16. Trends in Testing for Mycobacterium tuberculosis Complex From US Public Health Laboratories, 2009-2013.

    PubMed

    Tyrrell, Frances; Stafford, Cortney; Yakrus, Mitchell; Youngblood, Monica; Hill, Andrew; Johnston, Stephanie

    We investigated data from US public health laboratories funded through the Centers for Disease Control and Prevention's Tuberculosis Elimination and Laboratory Cooperative Agreement to document trends and challenges in meeting national objectives in tuberculosis (TB) laboratory diagnoses. We examined data on workload and turnaround time from public health laboratories' progress reports during 2009-2013. We reviewed methodologies, laboratory roles, and progress toward rapid detection of Mycobacterium tuberculosis complex through nucleic acid amplification (NAA) testing. We compared selected data with TB surveillance reports to estimate public health laboratories' contribution to national diagnostic services. During the study period, culture and drug susceptibility tests decreased, but NAA testing increased. Public health laboratories achieved turnaround time benchmarks for drug susceptibility tests at lower levels than for acid-fast bacilli smear and identification from culture. NAA positivity in laboratories among surveillance-reported culture-positive TB cases increased from 26.6% (2355 of 8876) in 2009 to 40.0% (2948 of 7358) in 2013. Public health laboratories provided an estimated 50.9% (4285 of 8413 in 2010) to 57.2% (4210 of 7358 in 2013) of culture testing and 88.3% (6822 of 7727 in 2011) to 94.4% (6845 of 7250 in 2012) of drug susceptibility tests for all US TB cases. Public health laboratories contribute substantially to TB diagnoses in the United States. Although testing volumes mostly decreased, the increase in NAA testing indicates continued progress in rapid M tuberculosis complex detection.

  17. Laboratory test for ice adhesion strength using commercial instrumentation.

    PubMed

    Wang, Chenyu; Zhang, Wei; Siva, Adarsh; Tiea, Daniel; Wynne, Kenneth J

    2014-01-21

    A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM.

  18. Pilot instrumentation of a Superpave test section at the Kansas Accelerated Testing laboratory

    DOT National Transportation Integrated Search

    2003-04-01

    Two Superpave test sections were constructed at the Kansas Accelerated Testing Laboratory (K-ATL) with 12.5 mm (2 in) nominal maximum size Superpave mixture (SM-2A) with varying percentages (15 and 30 percent) of river sand. A 150 kN (34 kip) tandem ...

  19. Bill Kerslake Preparing a Test in the Rocket Laboratory

    NASA Image and Video Library

    1952-10-21

    William Kerslake, a combustion researcher at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory, examines the setup of a transparent rocket in a Rocket Laboratory test cell. Kerslake joined NACA Lewis the previous summer after graduating from the Case Institute of Technology with a chemistry degree. His earliest professional research concentrated on combustion instability in small rocket engines. While at Case the quiet, 250-pound Kerslake also demonstrated his athletic prowess on the wrestling team. He continued wrestling for roughly a decade afterwards while conducting his research with the NACA. Kerslake participated in Olympic competitions in Helsinki (1952), Melbourne (1956), and Rome (1960). He won 30 national championships in three different weight classes and captured the gold at the 1955 Pan American Games in Mexico City. Kerslake accomplished all this while maintaining his research career, raising a family, and paying his own expenses. As his wrestling career was winding down in the early 1960s, Kerslake’s professional career changed, as well. He was transferred to Harold Kaufman’s Electrostatic Propulsion Systems Section in the new Electromagnetic Propulsion Division. Kaufman was developing the first successful ion engine at the time, and Kerslake spent the remainder of his career working in the electric propulsion field. He was heavily involved in the two Space Electric Rocket Test (SERT) missions which demonstrated that the ion thrusters could successfully operate in space. Kerslake retired in 1985 with over 30 years of service.

  20. Returning Fourth-Year Students to the Classroom/Laboratory.

    ERIC Educational Resources Information Center

    Markert, Ronald J.; Ogilvie, Charles D.

    1980-01-01

    The Eighth Semester Program of the Texas College of Osteopathic Medicine reintroduces classroom-laboratory activities into the medical students' clinical years in an attempt to "round out" students' education. Topics include development of a medical practice, government and the physician, counseling skills, and nutrition inpatient care.…

  1. Performance testing of radiobioassay laboratories: In vivo measurements, Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLellan, J.A.; Traub, R.J.; Olsen, P.C.

    1990-04-01

    A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less

  2. Analysis and Test Support for Phillips Laboratory Precision Structures

    DTIC Science & Technology

    1998-11-01

    Air Force Research Laboratory ( AFRL ), Phillips Research Site . Task objectives centered...around analysis and structural dynamic test support on experiments within the Space Vehicles Directorate at Kirtland Air Force Base. These efforts help...support for Phillips Laboratory Precision Structures." Mr. James Goodding of CSA Engineering was the principal investigator for this task. Mr.

  3. Educational ultrasound nondestructive testing laboratory.

    PubMed

    Genis, Vladimir; Zagorski, Michael

    2008-09-01

    The ultrasound nondestructive evaluation (NDE) of materials course was developed for applied engineering technology students at Drexel University's Goodwin College of Professional Studies. This three-credit, hands-on laboratory course consists of two parts: the first part with an emphasis on the foundations of NDE, and the second part during which ultrasound NDE techniques are utilized in the evaluation of parts and materials. NDE applications are presented and applied through real-life problems, including calibration and use of the latest ultrasonic testing instrumentation. The students learn engineering and physical principles of measurements of sound velocity in different materials, attenuation coefficients, material thickness, and location and dimensions of discontinuities in various materials, such as holes, cracks, and flaws. The work in the laboratory enhances the fundamentals taught during classroom sessions. This course will ultimately result in improvements in the educational process ["The greater expectations," national panel report, http://www.greaterexpectations.org (last viewed February, 2008); R. M. Felder and R. Brent "The intellectual development of Science and Engineering Students. Part 2: Teaching to promote growth," J. Eng. Educ. 93, 279-291 (2004)] since industry is becoming increasingly reliant on the effective application of NDE technology and the demand on NDE specialists is increasing. NDE curriculum was designed to fulfill levels I and II NDE in theory and training requirements, according to American Society for Nondestructive Testing, OH, Recommended Practice No. SNT-TC-1A (2006).

  4. Laboratory test data on the stability of the STIS MAMAs

    NASA Technical Reports Server (NTRS)

    Joseph, Charles L.

    1997-01-01

    STIS has two MAMA detectors systems with distinctly different tube configurations. The first (designated BAND 1) has an opaque CsI photocathode deposited on the microchannel plate (MCP) providing wavelength coverage from 1150A to 1700A. The other MAMA (designated BAND 2) has a semitransparent CS2Te photocathode deposited on the faceplate in close proximity to the input of the MCP. It covers the 1650A to 3100A bandpass and serves as a backup for the short wavelength detector. Laboratory test data indicate that both of these detectors have good sensitivity, have good uniformity and provide stable response, making each capable of collecting data with a signal-to-noise ratio in excess of 100 per Space Telescope Imaging Spectrograph (STIS) optical resolution element. Over a multiyear development effort, a substantial body of laboratory test data (more than 6 GBytes spanning more than 6 years of collection) has accumulated on more than a dozen fabricated tubes. These tests even included a few destructive evaluations to examine the limitations and operating life. In addition, analyses where conducted regarding impact caused by the specified electronic tolerances and expected changes in the Hubble Space Telescope (HST) thermal environment. Perhaps the simplest test of stability is to collect a sequence of images, each with a uniform illumination, and use these individual "flat fields" to remove the pixel-to-pixel sensitivity in the other flat fields. These sequences typically spanned 3-5 weeks of time. The detectors are very stable, allowing the pixel-to-pixel sensitivity to be removed with good precision. The STIS specification for stability is 1% (sufficient for data with a S/N = 100) over a 1 week period and 2% over 30 days. All Engineering Model Units as well as Flight Detectors tested exceeded this specification.

  5. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    PubMed

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  6. Laboratory testing in primary care: A systematic review of health IT impacts.

    PubMed

    Maillet, Éric; Paré, Guy; Currie, Leanne M; Raymond, Louis; Ortiz de Guinea, Ana; Trudel, Marie-Claude; Marsan, Josianne

    2018-08-01

    Laboratory testing in primary care is a fundamental process that supports patient management and care. Any breakdown in the process may alter clinical information gathering and decision-making activities and can lead to medical errors and potential adverse outcomes for patients. Various information technologies are being used in primary care with the goal to support the process, maximize patient benefits and reduce medical errors. However, the overall impact of health information technologies on laboratory testing processes has not been evaluated. To synthesize the positive and negative impacts resulting from the use of health information technology in each phase of the laboratory 'total testing process' in primary care. We conducted a systematic review. Databases including Medline, PubMed, CINAHL, Web of Science and Google Scholar were searched. Studies eligible for inclusion reported empirical data on: 1) the use of a specific IT system, 2) the impacts of the systems to support the laboratory testing process, and were conducted in 3) primary care settings (including ambulatory care and primary care offices). Our final sample consisted of 22 empirical studies which were mapped to a framework that outlines the phases of the laboratory total testing process, focusing on phases where medical errors may occur. Health information technology systems support several phases of the laboratory testing process, from ordering the test to following-up with patients. This is a growing field of research with most studies focusing on the use of information technology during the final phases of the laboratory total testing process. The findings were largely positive. Positive impacts included easier access to test results by primary care providers, reduced turnaround times, and increased prescribed tests based on best practice guidelines. Negative impacts were reported in several studies: paper-based processes employed in parallel to the electronic process increased the potential

  7. Remotely accessible laboratory for MEMS testing

    NASA Astrophysics Data System (ADS)

    Sivakumar, Ganapathy; Mulsow, Matthew; Melinger, Aaron; Lacouture, Shelby; Dallas, Tim E.

    2010-02-01

    We report on the construction of a remotely accessible and interactive laboratory for testing microdevices (aka: MicroElectroMechancial Systems - MEMS). Enabling expanded utilization of microdevices for research, commercial, and educational purposes is very important for driving the creation of future MEMS devices and applications. Unfortunately, the relatively high costs associated with MEMS devices and testing infrastructure makes widespread access to the world of MEMS difficult. The creation of a virtual lab to control and actuate MEMS devices over the internet helps spread knowledge to a larger audience. A host laboratory has been established that contains a digital microscope, microdevices, controllers, and computers that can be logged into through the internet. The overall layout of the tele-operated MEMS laboratory system can be divided into two major parts: the server side and the client side. The server-side is present at Texas Tech University, and hosts a server machine that runs the Linux operating system and is used for interfacing the MEMS lab with the outside world via internet. The controls from the clients are transferred to the lab side through the server interface. The server interacts with the electronics required to drive the MEMS devices using a range of National Instruments hardware and LabView Virtual Instruments. An optical microscope (100 ×) with a CCD video camera is used to capture images of the operating MEMS. The server broadcasts the live video stream over the internet to the clients through the website. When the button is pressed on the website, the MEMS device responds and the video stream shows the movement in close to real time.

  8. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Duty Cycles for Laboratory Testing II.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld engines with the following steady-state duty cycle: G3 mode No. Engine speed a Torque(percent) b Weighting...

  9. 42 CFR 493.20 - Laboratories performing tests of moderate complexity.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Laboratories performing tests of moderate complexity. 493.20 Section 493.20 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General...

  10. 42 CFR 493.20 - Laboratories performing tests of moderate complexity.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Laboratories performing tests of moderate complexity. 493.20 Section 493.20 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General...

  11. Laboratory Practices of Beginning Secondary Science Teachers: A Five-Year Study

    ERIC Educational Resources Information Center

    Wong, Sissy S.; Firestone, Jonah B.; Luft, Julie A.; Weeks, Charles B.

    2013-01-01

    During the beginning years of teaching, science teachers develop the knowledge and skills needed to design and implement science laboratories. In this regard, this quantitative study focused on the reported laboratory practices of 61 beginning secondary science teachers who participated in four different induction programs. The results…

  12. The laboratory test utilization management toolbox

    PubMed Central

    Baird, Geoffrey

    2014-01-01

    Efficiently managing laboratory test utilization requires both ensuring adequate utilization of needed tests in some patients and discouraging superfluous tests in other patients. After the difficult clinical decision is made to define the patients that do and do not need a test, a wealth of interventions are available to the clinician and laboratorian to help guide appropriate utilization. These interventions are collectively referred to here as the utilization management toolbox. Experience has shown that some tools in the toolbox are weak and other are strong, and that tools are most effective when many are used simultaneously. While the outcomes of utilization management studies are not always as concrete as may be desired, what data is available in the literature indicate that strong utilization management interventions are safe and effective measures to improve patient health and reduce waste in an era of increasing financial pressure. PMID:24969916

  13. SOFIA®RSV: prospective laboratory evaluation and implementation of a rapid diagnostic test in a pediatric emergency ward.

    PubMed

    Tran, Léa C; Tournus, Céline; Dina, Julia; Morello, Rémy; Brouard, Jacques; Vabret, Astrid

    2017-06-26

    Respiratory syncytial virus (RSV) is responsible for severe respiratory infections and higher costs in medical care. The two aims of this work were to assess the performances of SOFIA ® RSV tests in "real-life-laboratory" conditions (study 1) and implemented at point-of-care testing in a pediatric emergency department (ED, study 2), during two consecutive winter seasons. In study 1, fresh nasopharyngeal swabs from patients of all ages were sampled in 1.5 ml of Universal virological Transport Medium (UTM) and prospectively tested using SOFIA ® RSV tests. In study 2, conducted in a pediatric ED, nasopharyngeal swabs were placed in 3 ml of UTM. All SOFIA ® RSV tests were confirmed by molecular testing, considered as reference method. The epidemiological and clinical features of tested patients, as well as the care of these patients after obtaining quick results were evaluated. The sensitivities of SOFIA ® RSV in infants (aged under 24 months) performed in the laboratory and in the pediatric ED were respectively 95% (95% CI: 86.8-98.1) and 74.8% (95% CI: 68.0-80.9) compared to PCR. In study 1, the sensitivity among children (from 2 to 15 years old) and adults (above 15 years old) dropped to 45% (95% CI: 23.1-68.5) and 59% (95% CI: 32.9-81.6), respectively. In study 2, there were some differences in bed-management of SOFIA ® RSV positive compared to SOFIA ® RSV negative infants. SOFIA ® RSV tests performed in the laboratory and in the pediatric ED show high and satisfactory sensitivities among young children under 24 months, which supports its robustness and reliability. However, the impact of these tests on patient care at point-of-care cannot be clearly assessed when considering the limits of the study 2 design.

  14. A 2000-hour cyclic endurance test of a laboratory model multipropellant resistojet

    NASA Technical Reports Server (NTRS)

    Morren, W. Earl; Sovey, James S.

    1987-01-01

    The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.

  15. Effectiveness of a computerized alert system based on re-testing intervals for limiting the inappropriateness of laboratory test requests.

    PubMed

    Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo

    2015-11-01

    There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; p<0.001). The total financial saving of test withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. System reliability of randomly vibrating structures: Computational modeling and laboratory testing

    NASA Astrophysics Data System (ADS)

    Sundar, V. S.; Ammanagi, S.; Manohar, C. S.

    2015-09-01

    The problem of determination of system reliability of randomly vibrating structures arises in many application areas of engineering. We discuss in this paper approaches based on Monte Carlo simulations and laboratory testing to tackle problems of time variant system reliability estimation. The strategy we adopt is based on the application of Girsanov's transformation to the governing stochastic differential equations which enables estimation of probability of failure with significantly reduced number of samples than what is needed in a direct simulation study. Notably, we show that the ideas from Girsanov's transformation based Monte Carlo simulations can be extended to conduct laboratory testing to assess system reliability of engineering structures with reduced number of samples and hence with reduced testing times. Illustrative examples include computational studies on a 10-degree of freedom nonlinear system model and laboratory/computational investigations on road load response of an automotive system tested on a four-post test rig.

  17. Laboratory Tests

    MedlinePlus

    ... PI CONNECT Research Network USIDNET Patient Registry IDF Survey Research IDF Surveys National Health Insurance Surveys Clinical Trials ... and Fellows Research USIDNET IDF Research Fund IDF Survey Research IDF Surveys Contact Us Search form Search Laboratory ...

  18. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2013-10-01 2013-10-01 false What is validity testing, and are laboratories...

  19. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2011-10-01 2011-10-01 false What is validity testing, and are laboratories...

  20. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2010-10-01 2010-10-01 false What is validity testing, and are laboratories...

  1. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2012-10-01 2012-10-01 false What is validity testing, and are laboratories...

  2. 49 CFR 40.89 - What is validity testing, and are laboratories required to conduct it?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.89 What is validity testing, and are laboratories required to conduct it? (a) Specimen validity testing is... 49 Transportation 1 2014-10-01 2014-10-01 false What is validity testing, and are laboratories...

  3. 42 CFR 493.1453 - Condition: Laboratories performing high complexity testing; clinical consultant.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... testing; clinical consultant. 493.1453 Section 493.1453 Public Health CENTERS FOR MEDICARE & MEDICAID... Condition: Laboratories performing high complexity testing; clinical consultant. The laboratory must have a clinical consultant who meets the requirements of § 493.1455 of this subpart and provides clinical...

  4. 42 CFR 493.1415 - Condition: Laboratories performing moderate complexity testing; clinical consultant.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... complexity testing; clinical consultant. 493.1415 Section 493.1415 Public Health CENTERS FOR MEDICARE... § 493.1415 Condition: Laboratories performing moderate complexity testing; clinical consultant. The laboratory must have a clinical consultant who meets the qualification requirements of § 493.1417 of this...

  5. A comparison of relative toxicity rankings by some small-scale laboratory tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Small-scale laboratory tests for fire toxicity, suitable for use in the average laboratory hood, are needed for screening and ranking materials on the basis of relative toxicity. The performance of wool, cotton, and aromatic polyamide under several test procedures is presented.

  6. Frederick National Laboratory Celebrates 40 Years | Poster

    Cancer.gov

    By Ashley DeVine, Staff Writer Forty years ago, what we now call the Frederick National Laboratory for Cancer Research was born. Here are some highlights in the facility’s history. October 19, 1971 – President Richard Nixon announced that Fort Detrick would be converted from a biological warfare facility to a cancer research center (Covert, Norman M., Cutting Edge: A History of Fort Detrick, Maryland, 1943–1993, pp. 85–87).

  7. Laboratory- and field-based testing as predictors of skating performance in competitive-level female ice hockey.

    PubMed

    Henriksson, Tommy; Vescovi, Jason D; Fjellman-Wiklund, Anncristine; Gilenstam, Kajsa

    2016-01-01

    The purpose of this study was to examine whether field-based and/or laboratory-based assessments are valid tools for predicting key performance characteristics of skating in competitive-level female hockey players. Cross-sectional study. Twenty-three female ice hockey players aged 15-25 years (body mass: 66.1±6.3 kg; height: 169.5±5.5 cm), with 10.6±3.2 years playing experience volunteered to participate in the study. The field-based assessments included 20 m sprint, squat jump, countermovement jump, 30-second repeated jump test, standing long jump, single-leg standing long jump, 20 m shuttle run test, isometric leg pull, one-repetition maximum bench press, and one-repetition maximum squats. The laboratory-based assessments included body composition (dual energy X-ray absorptiometry), maximal aerobic power, and isokinetic strength (Biodex). The on-ice tests included agility cornering s-turn, cone agility skate, transition agility skate, and modified repeat skate sprint. Data were analyzed using stepwise multivariate linear regression analysis. Linear regression analysis was used to establish the relationship between key performance characteristics of skating and the predictor variables. Regression models (adj R (2)) for the on-ice variables ranged from 0.244 to 0.663 for the field-based assessments and from 0.136 to 0.420 for the laboratory-based assessments. Single-leg tests were the strongest predictors for key performance characteristics of skating. Single leg standing long jump alone explained 57.1%, 38.1%, and 29.1% of the variance in skating time during transition agility skate, agility cornering s-turn, and modified repeat skate sprint, respectively. Isokinetic peak torque in the quadriceps at 90° explained 42.0% and 32.2% of the variance in skating time during agility cornering s-turn and modified repeat skate sprint, respectively. Field-based assessments, particularly single-leg tests, are an adequate substitute to more expensive and time

  8. Laboratory- and field-based testing as predictors of skating performance in competitive-level female ice hockey

    PubMed Central

    Henriksson, Tommy; Vescovi, Jason D; Fjellman-Wiklund, Anncristine; Gilenstam, Kajsa

    2016-01-01

    Objectives The purpose of this study was to examine whether field-based and/or laboratory-based assessments are valid tools for predicting key performance characteristics of skating in competitive-level female hockey players. Design Cross-sectional study. Methods Twenty-three female ice hockey players aged 15–25 years (body mass: 66.1±6.3 kg; height: 169.5±5.5 cm), with 10.6±3.2 years playing experience volunteered to participate in the study. The field-based assessments included 20 m sprint, squat jump, countermovement jump, 30-second repeated jump test, standing long jump, single-leg standing long jump, 20 m shuttle run test, isometric leg pull, one-repetition maximum bench press, and one-repetition maximum squats. The laboratory-based assessments included body composition (dual energy X-ray absorptiometry), maximal aerobic power, and isokinetic strength (Biodex). The on-ice tests included agility cornering s-turn, cone agility skate, transition agility skate, and modified repeat skate sprint. Data were analyzed using stepwise multivariate linear regression analysis. Linear regression analysis was used to establish the relationship between key performance characteristics of skating and the predictor variables. Results Regression models (adj R2) for the on-ice variables ranged from 0.244 to 0.663 for the field-based assessments and from 0.136 to 0.420 for the laboratory-based assessments. Single-leg tests were the strongest predictors for key performance characteristics of skating. Single leg standing long jump alone explained 57.1%, 38.1%, and 29.1% of the variance in skating time during transition agility skate, agility cornering s-turn, and modified repeat skate sprint, respectively. Isokinetic peak torque in the quadriceps at 90° explained 42.0% and 32.2% of the variance in skating time during agility cornering s-turn and modified repeat skate sprint, respectively. Conclusion Field-based assessments, particularly single-leg tests, are an adequate

  9. SINGLE EVENT EFFECTS TEST FACILITY AT OAK RIDGE NATIONAL LABORATORY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riemer, Bernie; Gallmeier, Franz X; Dominik, Laura J

    2015-01-01

    Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of ICs and systems for use in radiation environments requiresmore » the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.« less

  10. Changes in laboratory test results and diagnostic imaging presentation before the detection of occupational cholangiocarcinoma.

    PubMed

    Kubo, Shoji; Takemura, Shigekazu; Sakata, Chikaharu; Urata, Yorihisa; Nishioka, Takayoshi; Nozawa, Akinori; Kinoshita, Masahiko; Hamano, Genya; Nakanuma, Yasuni; Endo, Ginji

    2014-01-01

    A cholangiocarcinoma outbreak among workers of an offset color proof-printing department in a printing company was recently reported. It is important to understand the clinical course leading to occupational cholangiocarcinoma development for investigation of the carcinogenesis process and for surveillance and early detection. We evaluated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma. We investigated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma in 2 patients because the data were available. Results The clinical courses observed in the 2 participating patients showed persistent elevation of serum γ-glutamyl transpeptidase levels with or without elevated serum levels of alanine aminotransferase and/or aspartate aminotransferase before cholangiocarcinoma detection. Dilatation of the bile ducts without tumor-induced stenosis was observed several years before cholangiocarcinoma detection and progressed gradually in both patients. The serum concentration of carbohydrate 19-9 also increased prior to cholangiocarcinoma detection in both patients. Eventually, observation of stenosis of the bile duct and a space-occupying lesion strongly suggested cholangiocarcinoma. Pathological examination of the resected specimens showed chronic bile duct injury and neoplastic lesions, such as "biliary intraepithelial neoplasia" and "intraductal papillary neoplasm of the bile duct" in various sites of the bile ducts, particularly in the dilated bile ducts. The changes in laboratory test results and diagnostic imaging might be related to the development of cholangiocarcinoma. It is important to monitor diagnostic imaging presentation and laboratory test results in workers with extended exposure to organic solvents.

  11. Flight Testing the Landing Radar for Mars Science Laboratory

    NASA Image and Video Library

    2011-06-21

    A NASA Dryden Flight Research Center F/A-18 852 aircraft performs a roll during June 2011 flight tests of a Mars landing radar. A test model of the landing radar for NASA Mars Science Laboratory mission is inside a pod under the aircraft left wing.

  12. Reflections on "YouTestTube.com": An Online Video-Sharing Platform to Engage Students with Chemistry Laboratory Classes

    ERIC Educational Resources Information Center

    McClean, Stephen; McCartan, Kenneth G.; Meskin, Sheryl; Gorges, Beronia; Hagan, W. Paul

    2016-01-01

    This paper describes the construction and development of YouTestTube.com, a YouTube clone website to facilitate video-sharing, social networking, and reflections of chemistry laboratory classes for year one students within the School of Biomedical Sciences at Ulster University. The practice was first introduced in the 2008/09 academic year and has…

  13. The Role of Laboratory Tests in Crohn’s Disease

    PubMed Central

    Cappello, Maria; Morreale, Gaetano Cristian

    2016-01-01

    In the past, laboratory tests were considered of limited value in Crohn’s disease (CD). In the era of biologics, laboratory tests have become essential to evaluate the inflammatory burden of the disease (C-reactive protein, fecal calprotectin) since symptoms-based scores are subjective, to predict the response to pharmacological options and the risk of relapse, to discriminate CD from ulcerative colitis, to select candidates to anti-tumor necrosis factors [screening tests looking for hepatitis B virus and hepatitis C virus status and latent tuberculosis], to assess the risk of adverse events (testing for thiopurine metabolites and thiopurine-methyltransferase activity), and to personalize and optimize therapy (therapeutic drug monitoring). Pharmacogenetics, though presently confined to the assessment of thiopurineme methyltransferase polymorphisms and hematological toxicity associated with thiopurine treatment, is a promising field that will contribute to a better understanding of the molecular mechanisms of the variability in response to the drugs used in CD with the attempt to expand personalized care and precision medicine strategies. PMID:27656094

  14. An experimental test of an extended discretion approach for high school biology laboratory investigations

    NASA Astrophysics Data System (ADS)

    Leonard, William H.; Cavana, Gordon R.; Lowery, Lawrence F.

    Discretion-the exercise of independent judgment-was observed to be lacking in most commercially available laboratory investigations for high school biology. An Extended Discretion (ED) laboratory approach was developed and tested experimentally against the BSCS Green Version laboratory program, using ten classes of 10th-grade biology in a suburban California high school. Five teachers were each assigned one experimental and one control group. The primary differences between the two approaches were that the BSCS was more prescriptive and directive than the ED approach and the ED approach increased discretionary demands upon the student over the school year. A treatment verification procedure showed statistically significant differences between the two approaches. The hypothesis under test was that when high school biology students are taught laboratory concepts under comparatively high discretionary demands, they would perform as well as or better than a similar group of students taught with BSCS Green Version investigations. A second hypothesis was that teachers would prefer to use the ED approach over the BSCS approach for their future classes. A t analysis between experimental and control groups for each teacher was employed. There were significant differences in favor of the ED group on laboratory report scores for three teachers and no differences for two teachers. There were significant differences in favor of the ED group on laboratory concepts quiz scores for three teachers, no differences for one teacher, and significant differences in favor of the BSCS group for only one teacher. A t analysis of teacher evaluation of the two approaches showed a significant teacher preference overall for the ED approach. Both experimental hypotheses were accepted. The ED approach was observed to be difficult for students at first, but it was found to be a workable and productive means of teaching laboratory concepts in biology which also required extensive use of individual

  15. Content of children's loss of control eating episodes assessed by self-report and laboratory test meal

    PubMed Central

    Theim, Kelly R.; Wilfley, Denise E.; Beach, Elizabeth; Tanofsky-Kraff, Marian; Goldschmidt, Andrea B.

    2014-01-01

    Pediatric loss of control (LOC) eating heightens risk for excessive weight gain and further disordered eating. Assessment of LOC typically involves self-report interview or laboratory test meal, although no study has concurrently examined data from both methods. We gathered eating episode data via interview (Child Eating Disorder Examination; ChEDE) and a laboratory test meal, among 22 overweight girls (aged 7-12 years) reporting LOC eating. Children consumed more energy during ChEDE episodes, although ChEDE and test meal episodes did not differ in macronutrient content. Episodes' correlation for amount consumed (grams) did not reach significance, p=.076. In exploratory analyses among the 7 children reporting LOC during the test meal, episodes were significantly correlated for grams consumed. Findings provide preliminary data to suggest that semi-structured interviews accurately capture children's LOC episode quantity. Episodes did not qualitatively differ, although children reported consuming more energy during self-reported episodes. Replication is warranted in larger studies. PMID:24019221

  16. Multi-Sensor Testing for Automated Rendezvous and Docking Sensor Testing at the Flight Robotics Laboratory

    NASA Technical Reports Server (NTRS)

    Brewster, L.; Johnston, A.; Howard, R.; Mitchell, J.; Cryan, S.

    2007-01-01

    The Exploration Systems Architecture defines missions that require rendezvous, proximity operations, and docking (RPOD) of two spacecraft both in Low Earth Orbit (LEO) and in Low Lunar Orbit (LLO). Uncrewed spacecraft must perform automated and/or autonomous rendezvous, proximity operations and docking operations (commonly known as AR&D). The crewed missions may also perform rendezvous and docking operations and may require different levels of automation and/or autonomy, and must provide the crew with relative navigation information for manual piloting. The capabilities of the RPOD sensors are critical to the success of the Exploration Program. NASA has the responsibility to determine whether the Crew Exploration Vehicle (CEV) contractor proposed relative navigation sensor suite will meet the requirements. The relatively low technology readiness level of AR&D relative navigation sensors has been carried as one of the CEV Project's top risks. The AR&D Sensor Technology Project seeks to reduce the risk by the testing and analysis of selected relative navigation sensor technologies through hardware-in-the-loop testing and simulation. These activities will provide the CEV Project information to assess the relative navigation sensors maturity as well as demonstrate test methods and capabilities. The first year of this project focused on a series of"pathfinder" testing tasks to develop the test plans, test facility requirements, trajectories, math model architecture, simulation platform, and processes that will be used to evaluate the Contractor-proposed sensors. Four candidate sensors were used in the first phase of the testing. The second phase of testing used four sensors simultaneously: two Marshall Space Flight Center (MSFC) Advanced Video Guidance Sensors (AVGS), a laser-based video sensor that uses retroreflectors attached to the target vehicle, and two commercial laser range finders. The multi-sensor testing was conducted at MSFC's Flight Robotics Laboratory (FRL

  17. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  18. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  19. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  20. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  1. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  2. Field Test: Results from the One Year Mission

    NASA Technical Reports Server (NTRS)

    Reschke, M. F.; Kozlovskaya, I. B.; Kofman, I. S.; Tomilovskaya, E. S.; Cerisano, J. M.; Rosenberg, M. J. F.; Bloomberg, J. J.; Stenger, M. B.; Lee, S. M. C.; Laurie, S. S.; hide

    2017-01-01

    The One Year Mission was designed to aid in determining the effect that extending the duration on orbit aboard the International Space Station (ISS) would have on a number of biological and physiological systems. Two crewmembers were selected to participate in this endeavor, one U.S. On-Orbit Segment (USOS) astronaut and one Russian cosmonaut. The Neuroscience and Cardiovascular and Vision Laboratories at the Johnson Space Center and the Sensory-Motor and Countermeasures Division within the Institute for Biomedical Problems were selected to investigate vestibular, sensorimotor and cardiovascular function with the two long-duration crewmembers using the established methodology developed for the Field Test (FT).

  3. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  4. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  5. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  6. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  7. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  8. A nationwide genetic testing survey in Italy, year 2007.

    PubMed

    Dallapiccola, Bruno; Torrente, Isabella; Agolini, Emanuele; Morena, Arnaldo; Mingarelli, Rita

    2010-02-01

    The aim of this study was to collect the practices of cytogenetic and molecular genetic testing and genetic counseling activities in Italy in the year 2007 and provide guidance to the national and regional health systems to improve the organization of genetic services. A web-based survey was carried out to assess the total number and the type of analyses, the number and type of genetic counseling sessions, and the personnel attending these activities. The quality management system of the responding structures, in terms of certification and accreditation standards, was also investigated. The appropriateness of requests for genetic testing was evaluated for six disorders. Data were collected from 278 responding centers, half of which were located in the northern regions of the country. Twenty-eight percent of the total were certified according to quality standards. A total of 217 molecular genetic and 171 cytogenetic laboratories, and 102 clinical genetic services were surveyed. About 560,000 genetic tests, including 311,069 cytogenetic and 248,691 molecular genetic analyses of 556 genes, were recorded. The fetal karyotype was examined on either trophoblast or amniocytes in about one of every 4.4 pregnancies. Only 11.5% of cytogenetic analyses and 13.5% of molecular tests were accompanied by genetic counseling. Concerning the appropriateness of a request for genetic testing, a low congruity was found between the clinical diagnosis and the laboratory results. This study highlights the need for reorganizing the genetic structure network in Italy, which at present is oversized, improving the quality management systems, expanding the availability of testing for rare disease genes, and improving access to pretest and posttest genetic counseling.

  9. The demand for pregnancy testing: The Aschheim–Zondek reaction, diagnostic versatility, and laboratory services in 1930s Britain

    PubMed Central

    Olszynko-Gryn, Jesse

    2014-01-01

    The Aschheim–Zondek reaction is generally regarded as the first reliable hormone test for pregnancy and as a major product of the ‘heroic age’ of reproductive endocrinology. Invented in Berlin in the late 1920s, by the mid 1930s a diagnostic laboratory in Edinburgh was performing thousands of tests every year for doctors around Britain. In her classic history of antenatal care, sociologist Ann Oakley claimed that the Aschheim–Zondek test launched a ‘modern era’ of obstetric knowledge, which asserted its superiority over that of pregnant women. This article reconsiders Oakley’s claim by examining how pregnancy testing worked in practice. It explains the British adoption of the test in terms less of the medicalisation of pregnancy than of clinicians’ increasing general reliance on laboratory services for differential diagnosis. Crucially, the Aschheim–Zondek reaction was a test not directly for the fetus, but for placental tissue. It was used, less as a yes-or-no test for ordinary pregnancy, than as a versatile diagnostic tool for the early detection of malignant tumours and hormonal deficiencies believed to cause miscarriage. This test was as much a product of oncology and the little-explored world of laboratory services as of reproductive medicine. PMID:24388014

  10. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  11. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  12. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  13. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  14. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If... request that a commercial test be made to determine the percentage clean yield of the wool or hair. (b... the wool or hair in dispute to be selected and tested by a commercial method approved by the...

  15. Human Papillomavirus (HPV) Genotyping: Automation and Application in Routine Laboratory Testing

    PubMed Central

    Torres, M; Fraile, L; Echevarria, JM; Hernandez Novoa, B; Ortiz, M

    2012-01-01

    A large number of assays designed for genotyping human papillomaviruses (HPV) have been developed in the last years. They perform within a wide range of analytical sensitivity and specificity values for the different viral types, and are used either for diagnosis, epidemiological studies, evaluation of vaccines and implementing and monitoring of vaccination programs. Methods for specific genotyping of HPV-16 and HPV-18 are also useful for the prevention of cervical cancer in screening programs. Some commercial tests are, in addition, fully or partially automated. Automation of HPV genotyping presents advantages such as the simplicity of the testing procedure for the operator, the ability to process a large number of samples in a short time, and the reduction of human errors from manual operations, allowing a better quality assurance and a reduction of cost. The present review collects information about the current HPV genotyping tests, with special attention to practical aspects influencing their use in clinical laboratories. PMID:23248734

  16. Laboratory compliance with the American Society of Clinical Oncology/College of American Pathologists human epidermal growth factor receptor 2 testing guidelines: a 3-year comparison of validation procedures.

    PubMed

    Dyhdalo, Kathryn S; Fitzgibbons, Patrick L; Goldsmith, Jeffery D; Souers, Rhona J; Nakhleh, Raouf E

    2014-07-01

    The American Society of Clinical Oncology/College of American Pathologists (ASCO/CAP) published guidelines in 2007 regarding testing accuracy, interpretation, and reporting of results for HER2 studies. A 2008 survey identified areas needing improved compliance. To reassess laboratory response to those guidelines following a full accreditation cycle for an updated snapshot of laboratory practices regarding ASCO/CAP guidelines. In 2011, a survey was distributed with the HER2 immunohistochemistry (IHC) proficiency testing program identical to the 2008 survey. Of the 1150 surveys sent, 977 (85.0%) were returned, comparable to the original survey response in 2008 (757 of 907; 83.5%). New participants submitted 124 of 977 (12.7%) surveys. The median laboratory accession rate was 14,788 cases with 211 HER2 tests performed annually. Testing was validated with fluorescence in situ hybridization in 49.1% (443 of 902) of the laboratories; 26.3% (224 of 853) of the laboratories used another IHC assay. The median number of cases to validate fluorescence in situ hybridization (n = 40) and IHC (n = 27) was similar to those in 2008. Ninety-five percent concordance with fluorescence in situ hybridization was achieved by 76.5% (254 of 332) of laboratories for IHC(-) findings and 70.4% (233 of 331) for IHC(+) cases. Ninety-five percent concordance with another IHC assay was achieved by 71.1% (118 of 168) of the laboratories for negative findings and 69.6% (112 of 161) of the laboratories for positive cases. The proportion of laboratories interpreting HER2 IHC using ASCO/CAP guidelines (86.6% [798 of 921] in 2011; 83.8% [605 of 722] in 2008) remains similar. Although fixation time improvements have been made, assay validation deficiencies still exist. The results of this survey were shared within the CAP, including the Laboratory Accreditation Program and the ASCO/CAP panel revising the HER2 guidelines published in October 2013. The Laboratory Accreditation Program checklist was

  17. Proficiency testing of Hb A1c: a 4-year experience in Taiwan and the Asian Pacific region.

    PubMed

    Shiesh, Shu-Chu; Wiedmeyer, Hsiao-Mei; Kao, Jau-Tsuen; Vasikaran, Samuel D; Lopez, Joseph B

    2009-10-01

    The correlation between hemoglobin A(1c) (Hb A(1c)) and risk for complications in diabetic patients heightens the need to measure Hb A(1c) with accuracy. We evaluated the current performance for measuring Hb A(1c) in the Asian and Pacific region by examining data submitted by laboratories participating in the Taiwan proficiency-testing program. Five fresh-pooled blood samples were sent to participating laboratories twice each year. The results were evaluated against target values assigned by the National Glycohemoglobin Standardization Program network laboratories; a passing criterion of +/-7% of the target value was used. Measurement uncertainty at Hb A(1c) concentrations of 7.0% and 8.0% were determined. A total of 276 laboratories from 11 countries took part in the Hb A(1c) survey. At the Hb A(1c) concentrations tested method-specific interlaboratory imprecision (CVs) were 1.1%-13.9% in 2005, 1.3%-10.1% in 2006, 1.2%-8.2% in 2007, and 1.1%-6.1% in 2008. Differences between target values and median values from the commonly used methods ranged from -0.24% to 0.22% Hb A(1c) in 2008. In 2005 83% of laboratories passed the survey, and in 2008 93% passed. At 7.0% Hb A(1c), measurement uncertainty was on average 0.49% Hb A(1c). The use of accuracy-based proficiency testing with stringent quality criteria has improved the performance of Hb A(1c) testing in the Asian and Pacific laboratories during the 4 years of assessment.

  18. Safety in the Chemical Laboratory: Tested Disposal Methods for Chemical Wastes from Academic Laboratories.

    ERIC Educational Resources Information Center

    Armour, M. A.; And Others

    1985-01-01

    Describes procedures for disposing of dichromate cleaning solution, picric acid, organic azides, oxalic acid, chemical spills, and hydroperoxides in ethers and alkenes. These methods have been tested under laboratory conditions and are specific for individual chemicals rather than for groups of chemicals. (JN)

  19. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  20. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  1. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  2. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  3. Impact of routine real-time PCR testing of imported malaria over 4 years of implementation in a clinical laboratory.

    PubMed

    Shokoples, Sandra; Mukhi, Shamir N; Scott, Allison N; Yanow, Stephanie K

    2013-06-01

    In clinical laboratories, diagnosis of imported malaria is commonly performed by microscopy. However, the volume of specimens is generally low and maintaining proficiency in reading blood smears, particularly at the species level, is challenging in this setting. To address this problem, the Provincial Laboratory for Public Health (ProvLab) in Alberta, Canada, implemented real-time PCR for routine confirmation of all smear-positive samples in the province. Here we report our experience over a 4-year period (2008 to 2012) with this new diagnostic algorithm. While detection of Plasmodium falciparum by microscopy alone was accurate, real-time PCR served as an important adjunct to microscopy for the identification of non-falciparum species. In 18% of cases, the result was reported as non-falciparum or the species could not be identified by microscopy alone, and in all cases, the species was resolved by real-time PCR. In another 4% of cases, the species was misidentified by microscopy. To enhance surveillance for malaria, we integrated our demographic, clinical, and laboratory data into a new system developed by the Canadian Network for Public Health Intelligence, called the Malaria System for Online Surveillance (SOS). Using this application, we characterized our patient populations and travel history to identify risk factors associated with malaria infection abroad.

  4. The Altitude Laboratory for the Test of Aircraft Engines

    NASA Technical Reports Server (NTRS)

    Dickinson, H C; Boutell, H G

    1920-01-01

    Report presents descriptions, schematics, and photographs of the altitude laboratory for the testing of aircraft engines constructed at the Bureau of Standards for the National Advisory Committee for Aeronautics.

  5. Laboratory Diagnosis and Susceptibility Testing for Mycobacterium tuberculosis.

    PubMed

    Procop, Gary W

    2016-12-01

    The laboratory, which utilizes some of the most sophisticated and rapidly changing technologies, plays a critical role in the diagnosis of tuberculosis. Some of these tools are being employed in resource-challenged countries for the rapid detection and characterization of Mycobacterium tuberculosis. Foremost, the laboratory defines appropriate specimen criteria for optimal test performance. The direct detection of mycobacteria in the clinical specimen, predominantly done by acid-fast staining, may eventually be replaced by rapid-cycle PCR. The widespread use of the Xpert MTB/RIF (Cepheid) assay, which detects both M. tuberculosis and key genetic determinants of rifampin resistance, is important for the early detection of multidrug-resistant strains. Culture, using both broth and solid media, remains the standard for establishing the laboratory-based diagnosis of tuberculosis. Cultured isolates are identified far less commonly by traditional biochemical profiling and more commonly by molecular methods, such as DNA probes and broad-range PCR with DNA sequencing. Non-nucleic acid-based methods of identification, such as high-performance liquid chromatography and, more recently, matrix-assisted laser desorption/ionization-time of flight mass spectrometry, may also be used for identification. Cultured isolates of M. tuberculosis should be submitted for susceptibility testing according to standard guidelines. The use of broth-based susceptibility testing is recommended to significantly decrease the time to result. Cultured isolates may also be submitted for strain typing for epidemiologic purposes. The use of massive parallel sequencing, also known as next-generation sequencing, promises to continue to this molecular revolution in mycobacteriology, as whole-genome sequencing provides identification, susceptibility, and typing information simultaneously.

  6. [Patient satisfaction in a laboratory test collection unit].

    PubMed

    de Moura, Gisela Maria Schebella Souto; Hilleshein, Eunice Fabiani; Schardosim, Juliana Machado; Delgado, Kátia Simone

    2008-06-01

    This exploratory descriptive study aimed at identifying customer satisfaction attributes in the field of laboratory tests. Data were collected in 2006, using 104 interviews in a laboratorial unit inside a teaching hospital, using the critical incident technique, and submitted to content analysis. Three attribute categories were identified: time spent in waiting for care, interpersonal contact, and technical skills. These results subsidize the assessment of the current satisfaction survey tool, and point to its reformulation. They also allow the identification of improvement needs in customer attention, and provide elements to be taken into account in personnel selection, training programs, personnel performance assessment.

  7. Measurement accuracy of weighing and tipping-bucket rainfall intensity gauges under dynamic laboratory testing

    NASA Astrophysics Data System (ADS)

    Colli, M.; Lanza, L. G.; La Barbera, P.; Chan, P. W.

    2014-07-01

    The contribution of any single uncertainty factor in the resulting performance of infield rain gauge measurements still has to be comprehensively assessed due to the high number of real world error sources involved, such as the intrinsic variability of rainfall intensity (RI), wind effects, wetting losses, the ambient temperature, etc. In recent years the World Meteorological Organization (WMO) addressed these issues by fostering dedicated investigations, which revealed further difficulties in assessing the actual reference rainfall intensity in the field. This work reports on an extensive assessment of the OTT Pluvio2 weighing gauge accuracy when measuring rainfall intensity under laboratory dynamic conditions (time varying reference flow rates). The results obtained from the weighing rain gauge (WG) were also compared with a MTX tipping-bucket rain gauge (TBR) under the same test conditions. Tests were carried out by simulating various artificial precipitation events, with unsteady rainfall intensity, using a suitable dynamic rainfall generator. Real world rainfall data measured by an Ogawa catching-type drop counter at a field test site located within the Hong Kong International Airport (HKIA) were used as a reference for the artificial rain generation system. Results demonstrate that the differences observed between the laboratory and field performance of catching-type gauges are only partially attributable to the weather and operational conditions in the field. The dynamics of real world precipitation events is responsible for a large part of the measurement errors, which can be accurately assessed in the laboratory under controlled environmental conditions. This allows for new testing methodologies and the development of instruments with enhanced performance in the field.

  8. 42 CFR 493.1481 - Condition: Laboratories performing high complexity testing; cytotechnologist.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; cytotechnologist. 493.1481 Section 493.1481 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  9. 42 CFR 493.1481 - Condition: Laboratories performing high complexity testing; cytotechnologist.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; cytotechnologist. 493.1481 Section 493.1481 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  10. Simpler score of routine laboratory tests predicts liver fibrosis in patients with chronic hepatitis B.

    PubMed

    Zhou, Kun; Gao, Chun-Fang; Zhao, Yun-Peng; Liu, Hai-Lin; Zheng, Rui-Dan; Xian, Jian-Chun; Xu, Hong-Tao; Mao, Yi-Min; Zeng, Min-De; Lu, Lun-Gen

    2010-09-01

    In recent years, a great interest has been dedicated to the development of noninvasive predictive models to substitute liver biopsy for fibrosis assessment and follow-up. Our aim was to provide a simpler model consisting of routine laboratory markers for predicting liver fibrosis in patients chronically infected with hepatitis B virus (HBV) in order to optimize their clinical management. Liver fibrosis was staged in 386 chronic HBV carriers who underwent liver biopsy and routine laboratory testing. Correlations between routine laboratory markers and fibrosis stage were statistically assessed. After logistic regression analysis, a novel predictive model was constructed. This S index was validated in an independent cohort of 146 chronic HBV carriers in comparison to the SLFG model, Fibrometer, Hepascore, Hui model, Forns score and APRI using receiver operating characteristic (ROC) curves. The diagnostic values of each marker panels were better than single routine laboratory markers. The S index consisting of gamma-glutamyltransferase (GGT), platelets (PLT) and albumin (ALB) (S-index: 1000 x GGT/(PLT x ALB(2))) had a higher diagnostic accuracy in predicting degree of fibrosis than any other mathematical model tested. The areas under the ROC curves (AUROC) were 0.812 and 0.890 for predicting significant fibrosis and cirrhosis in the validation cohort, respectively. The S index, a simpler mathematical model consisting of routine laboratory markers predicts significant fibrosis and cirrhosis in patients with chronic HBV infection with a high degree of accuracy, potentially decreasing the need for liver biopsy.

  11. [Contribution of HCV core antigen testing in HCV diagnosis by test from the company Abbott Laboratories].

    PubMed

    Trbusek, J

    2009-11-01

    Detection of HCV core antigen as direct marker of hepatitis C infection clearly improves diagnosis of this disease (especially reduction of window period) and brings broad clinical utilization. The company Abbott Laboratories offers fully automated laboratory test for measurement of HCV core antigen on ARCHITECT analyzers.

  12. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  13. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  14. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  15. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  16. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  17. Expert Assessment of Conditions for Accredited Quality Management System Functioning in Testing Laboratories

    NASA Astrophysics Data System (ADS)

    Mytych, Joanna; Ligarski, Mariusz J.

    2018-03-01

    The quality management systems compliant with the ISO 9001:2009 have been thoroughly researched and described in detail in the world literature. The accredited management systems used in the testing laboratories and compliant with the ISO/IEC 17025:2005 have been mainly described in terms of the system design and implementation. They have also been investigated from the analytical point of view. Unfortunately, a low number of studies concerned the management system functioning in the accredited testing laboratories. The aim of following study was to assess the management system functioning in the accredited testing laboratories in Poland. On 8 October 2015, 1,213 accredited testing laboratories were present in Poland. They investigated various scientific areas and substances/objects. There are more and more such laboratories that have various problems and different long-term experience when it comes to the implementation, maintenance and improvement of the management systems. The article describes the results of the conducted expert assessment (survey) carried out to examine the conditions for the functioning of a management system in an accredited laboratory. It also focuses on the characteristics of the accredited research laboratories in Poland. The authors discuss the selection of the external and internal conditions that may affect the accredited management system. They show how the experts assessing the selected conditions were chosen. The survey results are also presented.

  18. Laboratory Directed Research and Development Annual Report - Fiscal Year 2000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, Darrell R.; Hughes, Pamela J.; Pearson, Erik W.

    The projects described in this report represent the Laboratory's investment in its future and are vital to maintaining the ability to develop creative solutions for the scientific and technical challenges faced by DOE and the nation. In accordance with DOE guidelines, the report provides, a) a director's statement, b) an overview of the laboratory's LDRD program, including PNNL's management process and a self-assessment of the program, c) a five-year project funding table, and d) project summaries for each LDRD project.

  19. Laboratory pavement polishing device (wear machine) versus field friction test units and accumulative traffic (ADT). Phase 2. Correlation study

    NASA Astrophysics Data System (ADS)

    Godwin, H. F.; Loyed, D. B.; Miley, W. G.; Page, G. C.

    1981-04-01

    The degree to which pavement wear (vehicular traffic) could be predicted from testing samples of in-service pavements in the laboratory pavement polishing device was determined. This investigation was made on asphaltic concrete pavements, primarily friction courses used in Florida. These pavements were tested at different levels of accumulative traffic (ADT) for approximately 2 years.

  20. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-02-15

    The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken.

  1. Diagnostic and laboratory test ordering in Northern Portuguese Primary Health Care: a cross-sectional study

    PubMed Central

    Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo

    2017-01-01

    Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family

  2. Continual planning and scheduling for managing patient tests in hospital laboratories.

    PubMed

    Marinagi, C C; Spyropoulos, C D; Papatheodorou, C; Kokkotos, S

    2000-10-01

    Hospital laboratories perform examination tests upon patients, in order to assist medical diagnosis or therapy progress. Planning and scheduling patient requests for examination tests is a complicated problem because it concerns both minimization of patient stay in hospital and maximization of laboratory resources utilization. In the present paper, we propose an integrated patient-wise planning and scheduling system which supports the dynamic and continual nature of the problem. The proposed combination of multiagent and blackboard architecture allows the dynamic creation of agents that share a set of knowledge sources and a knowledge base to service patient test requests.

  3. Nasolabial cyst: 18.5 year experience in a pathology laboratory.

    PubMed

    Lopes-Rocha, R; Dornela Verli, F; Lages Lima, N; Rocha Dos Santos, C R; Aparecida Marinho, S

    2011-01-01

    This paper offers a survey of nasolabial cysts diagnosed at the Pathology Laboratory of the Universidade Federal dos Vales do Jequitinhonha e Mucuri (Brazil) over a period of 18.5 years, and a case report. A retrospective study was carried out on biopsies performed at the Pathology Laboratory of the UFVJM School of Dentistry between January 1992 and July 2010. Among a total of 2730 histopathological exams of biopsies performed at the UFVJM Pathology Laboratory, 288 (10.54%) were different types of cysts, The prevalence of NLC was 0.29% (8 cases) in relation to the overall sample and 2.43% among all cysts. NLC only occurred in the female gender in the age group spanning from 25 to 62 years (mean: 40.00 years; standard deviation (SD): 13.48 years). The duration of evolution ranged from six to 18 months (mean: 12 months; SD: 3.79 months). The cysts were asymptomatic in 62.5% of cases. Cyst size ranged from 10 to 30 mm (mean: 16.86; SD: 8.00 mm). In six cases (75%), the radiographic exams were consistent with the final diagnosis, whereas there were no records of radiographic images in two cases (25%). Surgical excision was the treatment of choice for all cases. The characteristics of NLC, such as location, elevation of the nasal wing, disappearance of the nasolabial sulcus, nasal obstruction, floatation of the cyst and the presence of cystic liquid in the interior, are enough to suggest the diagnosis of this cyst. However, the confirmation of the diagnosis is performed through biopsy and histopathological analysis.

  4. 42 CFR 493.807 - Condition: Reinstatement of laboratories performing nonwaived testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Reinstatement of laboratories performing nonwaived testing. 493.807 Section 493.807 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS...

  5. 42 CFR 493.807 - Condition: Reinstatement of laboratories performing nonwaived testing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Reinstatement of laboratories performing nonwaived testing. 493.807 Section 493.807 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS...

  6. 42 CFR 493.1361 - Condition: Laboratories performing PPM procedures; testing personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing PPM procedures; testing personnel. 493.1361 Section 493.1361 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS...

  7. 42 CFR 493.1361 - Condition: Laboratories performing PPM procedures; testing personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing PPM procedures; testing personnel. 493.1361 Section 493.1361 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS...

  8. Motivational project-based laboratory for a common first year electrical engineering course

    NASA Astrophysics Data System (ADS)

    Nedic, Zorica; Nafalski, Andrew; Machotka, Jan

    2010-08-01

    Over the past few years many universities worldwide have introduced a common first year for all engineering disciplines. This is despite the opinion of many academics that large classes have negative effects on the learning outcomes of first year students. The University of South Australia is also faced with low motivation amongst engineering students studying non-major courses. In 2006, a project-based laboratory was successfully introduced for first year students enrolled in electrical disciplines, which increased student satisfaction, reduced the attrition rate and improved students' success rate. This paper presents the experiences with the project-based laboratory's implementation in three different projects in the common first year course, Electrical and Energy Systems, where each project aims to increase the motivation of students in one of three disciplines: electrical, mechanical or civil engineering.

  9. Beta-Testing Agreement | Frederick National Laboratory for Cancer Research

    Cancer.gov

    Beta-Testing Agreements are appropriate forlimited term evaluation and applications development of new software, technology, or equipment platforms by the Frederick National Laboratory in collaboration with an external commercial partner. It ma

  10. Dispensability of Annual Laboratory Follow-Up After More than 2 Years of Valproic Acid Use: A Systematic Review.

    PubMed

    Meijboom, Rosanne W; Grootens, Koen P

    2017-11-01

    The necessity of annual laboratory follow-up in patients treated with valproic acid (VPA) is controversial. We investigated the need for annual laboratory follow-up of liver enzymes, electrolytes, and full blood count (FBC) in patients treated with VPA. A systematic search in Evidence-Based Medicine Reviews (EBMR), MEDLINE, and EMBASE was undertaken in December 2016 to identify all published articles investigating or citing valproic acid, liver function disorders, electrolyte disorders, and FBC deviations. This review included 108 articles. As the number of participants and duration of the study was not adequate in most studies to detect rare adverse events, studies did not demonstrate a clear prevalence of hepatotoxicity. While a transient increase of transaminases is common and seldom harmful, severe hepatotoxicity is a rare phenomenon and is not prevented by routine laboratory monitoring. VPA had no relevant effect on serum calcium, sodium, potassium, and albumin. The prevalence of FBC varied from 0.6 to 27.8%, occurred mostly in the first 2 years of therapy, and was usually asymptomatic. Long-term monitoring in VPA treatment is only necessary when there have been dose adjustments, co-medication switches, or co-morbidity. In uncomplicated cases, annual laboratory follow-up may be discontinued after 2 years of VPA treatment. Encouraging patients to be vigilant is more effective in the detection of hepatotoxicity than laboratory testing. Follow-up of FBC at 3-6 months, 1 year, and 2 years after start or after a dose increase of VPA or interacting medication is sufficient.

  11. Transferability and inter-laboratory variability assessment of the in vitro bovine oocyte fertilization test.

    PubMed

    Tessaro, Irene; Modina, Silvia C; Crotti, Gabriella; Franciosi, Federica; Colleoni, Silvia; Lodde, Valentina; Galli, Cesare; Lazzari, Giovanna; Luciano, Alberto M

    2015-01-01

    The dramatic increase in the number of animals required for reproductive toxicity testing imposes the validation of alternative methods to reduce the use of laboratory animals. As we previously demonstrated for in vitro maturation test of bovine oocytes, the present study describes the transferability assessment and the inter-laboratory variability of an in vitro test able to identify chemical effects during the process of bovine oocyte fertilization. Eight chemicals with well-known toxic properties (benzo[a]pyrene, busulfan, cadmium chloride, cycloheximide, diethylstilbestrol, ketoconazole, methylacetoacetate, mifepristone/RU-486) were tested in two well-trained laboratories. The statistical analysis demonstrated no differences in the EC50 values for each chemical in within (inter-runs) and in between-laboratory variability of the proposed test. We therefore conclude that the bovine in vitro fertilization test could advance toward the validation process as alternative in vitro method and become part of an integrated testing strategy in order to predict chemical hazards on mammalian fertility. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Three-year customer satisfaction survey in laboratory medicine in a Chinese university hospital.

    PubMed

    Guo, Siqi; Duan, Yifei; Liu, Xiaojuan; Jiang, Yongmei

    2018-04-25

    Customer satisfaction is a key quality indicator of laboratory service. Patients and physicians are the ultimate customers in medical laboratory, and their opinions are essential components in developing a customer-oriented laboratory. A longitudinal investigation of customer satisfaction was conducted through questionnaires. We designed two different questionnaires and selected 1200 customers (600 outpatients and 600 physicians) to assess customer satisfaction every other year from 2012 to 2016. Items with scores <4 were considered unsatisfactory, and corrective actions should be taken. The completion rates of physicians were 96.8% in 2012, 97% in 2014 and 96.5% in 2016, whereas the rates of patients were 95.3%, 96.2% and 95.2%, respectively. In 2012, the most dissatisfaction items were test turnaround time (3.77 points) and service attitude (3.87 points) from physicians, whereas waiting time (3.58 points) and examination environment (3.64 points) were the most dissatisfaction items from patients. After corrective actions were taken, the result of satisfaction in 2014 was better, which illustrated our strategy was effective. However, some items remained to be less than 4, so we repeated the survey after modifying questionnaires in 2016. However, the general satisfaction points of the physicians and patients reduced in 2016, which reminded us of some influential factors we had neglected. By using dynamic survey of satisfaction, we can continuously find deficiencies in our laboratory services and take suitable corrective actions, thereby improving our service quality.

  13. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in the 80000 series of the Current Procedural Terminology published by the American Medical... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  14. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  15. Facilities to Support Beamed Energy Launch Testing at the Laser Hardened Materials Evaluation Laboratory (LHMEL)

    NASA Astrophysics Data System (ADS)

    Lander, Michael L.

    2003-05-01

    The Laser Hardened Materials Evaluation Laboratory (LHMEL) has been characterizing material responses to laser energy in support of national defense programs and the aerospace industry for the past 26 years. This paper reviews the overall resources available at LHMEL to support fundamental materials testing relating to impulse coupling measurement and to explore beamed energy launch concepts. Located at Wright-Patterson Air Force Base, Ohio, LHMEL is managed by the Air Force Research Laboratory Materials Directorate AFRL/MLPJ and operated by Anteon Corporation. The facility's advanced hardware is centered around carbon dioxide lasers producing output power up to 135kW and neodymium glass lasers producing up to 10 kilojoules of repetitively pulsed output. The specific capabilities of each laser device and related optical systems are discussed. Materials testing capabilities coupled with the laser systems are also described including laser output and test specimen response diagnostics. Environmental simulation capabilities including wind tunnels and large-volume vacuum chambers relevant to beamed energy propulsion are also discussed. This paper concludes with a summary of the procedures and methods by which the facility can be accessed.

  16. Environmental Measurements Laboratory fiscal year 1998: Accomplishments and technical activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, M.D.

    1999-01-01

    The Environmental Measurements Laboratory (EML) is government-owned, government-operated, and programmatically under the DOE Office of Environmental Management. The Laboratory is administered by the Chicago Operations Office. EML provides program management, technical assistance and data quality assurance for measurements of radiation and radioactivity relating to environmental restoration, global nuclear nonproliferation, and other priority issues for the Department of Energy, as well as for other government, national, and international organizations. This report presents the technical activities and accomplishments of EML for Fiscal Year 1998.

  17. Quality performance of laboratory testing in pharmacies: a collaborative evaluation.

    PubMed

    Zaninotto, Martina; Miolo, Giorgia; Guiotto, Adriano; Marton, Silvia; Plebani, Mario

    2016-11-01

    The quality performance and the comparability between results of pharmacies point-of-care-testing (POCT) and institutional laboratories have been evaluated. Eight pharmacies participated in the project: a capillary specimen collected by the pharmacist and, simultaneously, a lithium-heparin sample drawn by a physician of laboratory medicine for the pharmacy customers (n=106) were analyzed in the pharmacy and in the laboratory, respectively. Glucose, cholesterol, HDL-cholesterol, triglycerides, creatinine, uric acid, aspartate aminotransferase, alanine aminotransferase, were measured using: Reflotron, n=5; Samsung, n=1; Cardiocheck PA, n=1; Cholestech LDX, n=1 and Cobas 8000. The POCT analytical performance only (phase 2) were evaluated testing, in pharmacies and in the laboratory, the lithium heparin samples from a female drawn fasting daily in a week, and a control sample containing high concentrations of glucose, cholesterol and triglycerides. For all parameters, except triglycerides, the slopes showed a satisfactory correlation. For triglycerides, a median value higher in POCT in comparison to the laboratory (1.627 mmol/L vs. 0.950 mmol/L) has been observed. The agreement in the subjects classification, demonstrates that for glucose, 70% of the subjects show concentrations below the POCT recommended level (5.8-6.1 mmol/L), while 56% are according to the laboratory limit (<5.6 mmol/L). Total cholesterol exhibits a similar trend while POCT triglycerides show a greater percentage of increased values (21% vs. 9%). The reduction in triglycerides bias (phase 2) suggests that differences between POCT and central laboratory is attributable to a pre-analytical problem. The results confirm the acceptable analytical performance of POCT pharmacies and specific criticisms in the pre- and post-analytical phases.

  18. ["How can hospitals develop a beneficial relationship with laboratory testing companies?" - Chairmen's introductory remarks].

    PubMed

    Morita, Toshisuke; Kawano, Seiji

    2014-12-01

    The symposium was held with the Japanese Society of Laboratory Medicine and JACLaP to discuss the way to develop a beneficial relationship between hospitals and laboratory testing companies with co-chairing by Seiji Kawano, Kobe University and Toshisuke Morita, Toho University. Clinical testing is considered to be essential for medical diagnosis and treatment; however, it is difficult for a hospital to perform all clinical testing for various reasons, including cost-effectiveness. In this session, 4 guest speakers gave a talk from their viewpoints. Doctor Kawano talked about the results of a questionnaire filled out by 114 university hospitals on how to develop a beneficial relationship between hospitalsoand laboratory testing companies. Next, Mr. Shinji Ogawa, president and CEO of SRL, talked about favorable ways to utilize laboratory testing companies, sayingthat such companies, which have a variety of skills, are expected to offer new and advanced technologies to hospitals continuously, and abundant data which laboratory testing companies have should be used for the advancement of community medicine. Professor Koshiba, Hyogo Medical School, expressed his apprehension to develop a so-called branch lab. in university hospitals from his own experience, and concluded that a beneficial relationship with companies to perform tasks required by hospitals should be sought. The last speaker, Yuichi Setoyama, Mitsubishi Chemical Medience, talked about the new relationship between hospitals and laboratory testing companies, and emphasized that hospitals and such companies should know the strong and weak points of each other and build a mutually complementary system. After all presentations were over, a discussion with participants was held. Doctors of clinics said that the role of laboratory testing companies for large hospitals is different from that for small clinics, and such companies are indispensable for his everyday medical activities. Each medical institute has its

  19. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-01-01

    Introduction The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. Materials and methods A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. Results A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Conclusion Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken. PMID:28392741

  20. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    DTIC Science & Technology

    2018-03-26

    HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...Report March 2016 – August 2017 Approved for public release; distribution is unlimited U.S. Army Natick Soldier Research ...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  1. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    PubMed

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  2. Can MOND type hypotheses be tested in a free fall laboratory environment?

    NASA Astrophysics Data System (ADS)

    Das, Saurya; Patitsas, S. N.

    2013-05-01

    The extremely small accelerations of objects required for the onset of modified Newtonian dynamics, or modified Newtonian dynamics (MOND), makes testing the hypothesis in conventional terrestrial laboratories virtually impossible. This is due to the large background acceleration of Earth, which is transmitted to the acceleration of test objects within an apparatus. We show, however, that it may be possible to test MOND-type hypotheses with experiments using a conventional apparatus capable of tracking very small accelerations of its components but performed in locally inertial frames such as artificial satellites and other freely falling laboratories. For example, experiments involving an optical interferometer or a torsion balance in these laboratories would show nonlinear dynamics and displacement amplitudes larger than expected. These experiments may also be able to test potential violations of the strong equivalence principle by MOND and to distinguish between its two possible interpretations (modified inertia and modified gravity).

  3. ChemCam for Mars Science Laboratory rover, undergoing pre-flight testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2011-10-20

    Los Alamos National Laboratory and partners developed a laser instrument, ChemCam, that will ride on the elevated mast of the Mars Science Laboratory rover Curiosity. The system allows Curiosity to "zap" rocks from a distance, reading their chemical composition through spectroscopic analysis. In this video, laboratory shaker-table testing of the instrument ensures that all of its components are solidly attached and resistant to damage from the rigors of launch, travel and landing.

  4. ChemCam for Mars Science Laboratory rover, undergoing pre-flight testing

    ScienceCinema

    None

    2018-06-06

    Los Alamos National Laboratory and partners developed a laser instrument, ChemCam, that will ride on the elevated mast of the Mars Science Laboratory rover Curiosity. The system allows Curiosity to "zap" rocks from a distance, reading their chemical composition through spectroscopic analysis. In this video, laboratory shaker-table testing of the instrument ensures that all of its components are solidly attached and resistant to damage from the rigors of launch, travel and landing.

  5. LOINC, a universal standard for identifying laboratory observations: a 5-year update.

    PubMed

    McDonald, Clement J; Huff, Stanley M; Suico, Jeffrey G; Hill, Gilbert; Leavelle, Dennis; Aller, Raymond; Forrey, Arden; Mercer, Kathy; DeMoor, Georges; Hook, John; Williams, Warren; Case, James; Maloney, Pat

    2003-04-01

    The Logical Observation Identifier Names and Codes (LOINC) database provides a universal code system for reporting laboratory and other clinical observations. Its purpose is to identify observations in electronic messages such as Health Level Seven (HL7) observation messages, so that when hospitals, health maintenance organizations, pharmaceutical manufacturers, researchers, and public health departments receive such messages from multiple sources, they can automatically file the results in the right slots of their medical records, research, and/or public health systems. For each observation, the database includes a code (of which 25 000 are laboratory test observations), a long formal name, a "short" 30-character name, and synonyms. The database comes with a mapping program called Regenstrief LOINC Mapping Assistant (RELMA(TM)) to assist the mapping of local test codes to LOINC codes and to facilitate browsing of the LOINC results. Both LOINC and RELMA are available at no cost from http://www.regenstrief.org/loinc/. The LOINC medical database carries records for >30 000 different observations. LOINC codes are being used by large reference laboratories and federal agencies, e.g., the CDC and the Department of Veterans Affairs, and are part of the Health Insurance Portability and Accountability Act (HIPAA) attachment proposal. Internationally, they have been adopted in Switzerland, Hong Kong, Australia, and Canada, and by the German national standards organization, the Deutsches Instituts für Normung. Laboratories should include LOINC codes in their outbound HL7 messages so that clinical and research clients can easily integrate these results into their clinical and research repositories. Laboratories should also encourage instrument vendors to deliver LOINC codes in their instrument outputs and demand LOINC codes in HL7 messages they get from reference laboratories to avoid the need to lump so many referral tests under the "send out lab" code.

  6. The changing face of hemostasis testing in modern laboratories: consolidation, automation, and beyond.

    PubMed

    Lippi, Giuseppe; Plebani, Mario; Favaloro, Emmanuel J

    2015-04-01

    The reality of laboratory diagnostics as a whole, and hemostasis testing in particular, is evolving under new paradigms of efficiency. The driving forces of health care and laboratory diagnostics in the third millennium are mainly represented by macro- and microeconomics. In a world with limited resources, shattered by an unprecedented economic crisis, laboratory diagnostics is undergoing a substantial reorganization, with emergence of new models under the imperative of terms, such as bedside testing, consolidation, and networking. The paradigms under which these changes are being developed include a variety of environment, preanalytical, technological, professional, and health-care aspects. The maintenance of continued quality is indeed the major challenge to be faced in the foreseeable future. In fact, some challenges prepotently emerge during a consolidation process, which basically involve delayed testing, centrifugation, transportation, and stability of the specimens, as well as the potential mismatch of sample matrix. This article is aimed to provide an overview of the current economic scenario of laboratory diagnostics and discuss the changing face of hemostasis testing in modern laboratories, providing a synthetic overview about potential drawbacks of actualized solutions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Laboratory Safety Monitoring of Chronic Medications in Ambulatory Care Settings

    PubMed Central

    Hurley, Judith S; Roberts, Melissa; Solberg, Leif I; Gunter, Margaret J; Nelson, Winnie W; Young, Linda; Frost, Floyd J

    2005-01-01

    OBJECTIVE To evaluate laboratory safety monitoring in patients taking selected chronic prescription drugs. DESIGN Retrospective study using 1999–2001 claims data to calculate rates of missed laboratory tests (potential laboratory monitoring errors). Eleven drugs/drug groups and 64 laboratory tests were evaluated. SETTING Two staff/network model health maintenance organizations. PATIENTS Continuously enrolled health plan members age≥19 years taking ≥1 chronic medications. MEASUREMENTS AND MAIN RESULTS Among patients taking chronic medications (N=29,823 in 1999, N=32,423 in 2000, and N=36,811 in 2001), 47.1% in 1999, 45.0% in 2000, and 44.0% in 2001 did not receive ≥1 test recommended for safety monitoring. Taking into account that patients were sometimes missing more than 1 test for a given drug and that patients were frequently taking multiple drugs, the rate of all potential laboratory monitoring errors was 849/1,000 patients/year in 1999, 810/1,000 patients/year in 2000, and 797/1,000 patients/year in 2001. Rates of potential laboratory monitoring errors varied considerably across individual drugs and laboratory tests. CONCLUSIONS Lapses in laboratory monitoring of patients taking selected chronic medications were common. Further research is needed to determine whether, and to what extent, this failure to monitor patients is associated with adverse clinical outcomes. PMID:15857489

  8. Metastable Radioxenon Verification Laboratory (MRVL) Year-End Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, Matthew W.; Hayes, James C.; Lidey, Lance S.

    2014-11-07

    This is the year end report that is due to the client. The MRVL system is designed to measure multiple radioxenon isotopes ( 135Xe, 133Xe, 133mXe and 133mXe) simultaneously. The system has 12 channels to load samples and make nuclear measurements. Although the MRVL system has demonstrated excellent stability in measurements of Xe-133 and Xe-135 over the year of evaluation prior to delivery, there has been concern about system stability over measurements performed on samples with orders of magnitude different radioactivity, and samples containing multiple isotopes. To address these concerns, a series of evaluation test have been performed at themore » end-user laboratory. The evaluation was performed in two separate phases. Phase 1 made measurements on isotopically pure Xe-133 from high radioactivity down to the system background levels of activity, addressing the potential count rate dependencies when activities change from extreme high to very low. The second phase performed measurements on samples containing multiple isotopes (Xe-135, Xe-133 and Xe-133m), and addressed concerns about the dependence of isotopic concentrations on the presence of additional isotopes. The MRVL showed a concentration dependence on the Xe-133 due to the amount of Xe-133m that was in the sample. The dependency is due to the decay of Xe-133m into Xe-133. This document focuses on the second phase and will address the analysis used to account for ingrowth of Xe-133 from Xe-133m.« less

  9. 76 FR 49491 - Medicare Program; Section 3113: The Treatment of Certain Complex Diagnostic Laboratory Tests...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-10

    ...] Medicare Program; Section 3113: The Treatment of Certain Complex Diagnostic Laboratory Tests Demonstration... code under the Treatment of Certain Complex Diagnostic Laboratory Tests Demonstration. The deadline for... interested parties of an opportunity to participate in the Treatment of Certain Complex Diagnostic Laboratory...

  10. Celebrating 50 Years of Testing

    NASA Image and Video Library

    2016-04-19

    What better way to mark 50 years of rocket engine testing than with a rocket engine test? Stennis Space Center employees enjoyed a chance to view an RS-68 engine test at the B-1 Test Stand on April 19, almost 50 years to the day that the first test was conducted at the south Mississippi site in 1966. The test viewing was part of a weeklong celebration of the 50th year of rocket engine testing at Stennis. The first test at the site occurred April 23, 1966, with a 15-second firing of a Saturn V second stage prototype (S-II-C) on the A-2 Test Stand. The center subsequently tested Apollo rocket stages that carried humans to the moon and every main engine used to power 135 space shuttle missions. It currently tests engines for NASA’s new Space Launch System vehicle.

  11. The role biomedical science laboratories can play in improving science knowledge and promoting first-year nursing academic success

    NASA Astrophysics Data System (ADS)

    Arneson, Pam

    The Role Biomedical Science Laboratories Can Play In Improving Science Knowledge and Promoting First-Year Nursing Academic Success The need for additional nursing and health care professionals is expected to increase dramatically over the next 20 years. With this in mind, students must have strong biomedical science knowledge to be competent in their field. Some studies have shown that participation in bioscience laboratories can enhance science knowledge. If this is true, an analysis of the role bioscience labs have in first-year nursing academic success is apposite. In response, this study sought to determine whether concurrent enrollment in anatomy and microbiology lecture and lab courses improved final lecture course grades. The investigation was expanded to include a comparison of first-year nursing GPA and prerequisite bioscience concurrent lecture/lab enrollment. Additionally, research has indicated that learning is affected by student perception of the course, instructor, content, and environment. To gain an insight regarding students' perspectives of laboratory courses, almost 100 students completed a 20-statement perception survey to understand how lab participation affects learning. Data analyses involved comparing anatomy and microbiology final lecture course grades between students who concurrently enrolled in the lecture and lab courses and students who completed the lecture course alone. Independent t test analyses revealed that there was no significant difference between the groups for anatomy, t(285) = .11, p = .912, but for microbiology, the lab course provided a significant educational benefit, t(256) = 4.47, p = .000. However, when concurrent prerequisite bioscience lecture/lab enrollment was compared to non-concurrent enrollment for first-year nursing GPA using independent t test analyses, no significant difference was found for South Dakota State University, t(37) = -1.57, p = .125, or for the University of South Dakota, t(38) = -0.46, p

  12. Public health consequences of a false-positive laboratory test result for Brucella--Florida, Georgia, and Michigan, 2005.

    PubMed

    2008-06-06

    Human brucellosis, a nationally notifiable disease, is uncommon in the United States. Most human cases have occurred in returned travelers or immigrants from regions where brucellosis is endemic, or were acquired domestically from eating illegally imported, unpasteurized fresh cheeses. In January 2005, a woman aged 35 years who lived in Nassau County, Florida, received a diagnosis of brucellosis, based on results of a Brucella immunoglobulin M (IgM) enzyme immunoassay (EIA) performed in a commercial laboratory using analyte specific reagents (ASRs); this diagnosis prompted an investigation of dairy products in two other states. Subsequent confirmatory antibody testing by Brucella microagglutination test (BMAT) performed at CDC on the patient's serum was negative. The case did not meet the CDC/Council of State and Territorial Epidemiologists' (CSTE) definition for a probable or confirmed brucellosis case, and the initial EIA result was determined to be a false positive. This report summarizes the case history, laboratory findings, and public health investigations. CDC recommends that Brucella serology testing only be performed using tests cleared or approved by the Food and Drug Administration (FDA) or validated under the Clinical Laboratory Improvement Amendments (CLIA) and shown to reliably detect the presence of Brucella infection. Results from these tests should be considered supportive evidence for recent infection only and interpreted in the context of a clinically compatible illness and exposure history. EIA is not considered a confirmatory Brucella antibody test; positive screening test results should be confirmed by Brucella-specific agglutination (i.e., BMAT or standard tube agglutination test) methods.

  13. Implementation of a virtual laboratory for training on sound insulation testing and uncertainty calculations in acoustic tests.

    PubMed

    Asensio, C; Gasco, L; Ruiz, M; Recuero, M

    2015-02-01

    This paper describes a methodology and case study for the implementation of educational virtual laboratories for practice training on acoustic tests according to international standards. The objectives of this activity are (a) to help the students understand and apply the procedures described in the standards and (b) to familiarize the students with the uncertainty in measurement and its estimation in acoustics. The virtual laboratory will not focus on the handling and set-up of real acoustic equipment but rather on procedures and uncertainty. The case study focuses on the application of the virtual laboratory for facade sound insulation tests according to ISO 140-5:1998 (International Organization for Standardization, Geneva, Switzerland, 1998), and the paper describes the causal and stochastic models and the constraints applied in the virtual environment under consideration. With a simple user interface, the laboratory will provide measurement data that the students will have to process to report the insulation results that must converge with the "virtual true values" in the laboratory. The main advantage of the virtual laboratory is derived from the customization of factors in which the student will be instructed or examined (for instance, background noise correction, the detection of sporadic corrupted observations, and the effect of instrument precision).

  14. Mars Science Laboratory Boot Robustness Testing

    NASA Technical Reports Server (NTRS)

    Banazadeh, Payam; Lam, Danny

    2011-01-01

    Mars Science Laboratory (MSL) is one of the most complex spacecrafts in the history of mankind. Due to the nature of its complexity, a large number of flight software (FSW) requirements have been written for implementation. In practice, these requirements necessitate very complex and very precise flight software with no room for error. One of flight software's responsibilities is to be able to boot up and check the state of all devices on the spacecraft after the wake up process. This boot up and initialization is crucial to the mission success since any misbehavior of different devices needs to be handled through the flight software. I have created a test toolkit that allows the FSW team to exhaustively test the flight software under variety of different unexpected scenarios and validate that flight software can handle any situation after booting up. The test includes initializing different devices on spacecraft to different configurations and validate at the end of the flight software boot up that the flight software has initialized those devices to what they are suppose to be in that particular scenario.

  15. 23 CFR 637.209 - Laboratory and sampling and testing personnel qualifications.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... sampling and testing personnel. (c) Conflict of interest. In order to avoid an appearance of a conflict of interest, any qualified non-STD laboratory shall perform only one of the following types of testing on the...

  16. Balance Screening of Vestibular Function in Subjects Aged 4 Years and Older: A Living Laboratory Experience

    PubMed Central

    Bermúdez Rey, María Carolina; Clark, Torin K.; Merfeld, Daniel M.

    2017-01-01

    To better understand the various individual factors that contribute to balance and the relation to fall risk, we performed the modified Romberg Test of Standing Balance on Firm and Compliant Support, with 1,174 participants between 4 and 83 years of age. This research was conducted in the Living Laboratory® at the Museum of Science, Boston. We specifically focus on balance test condition 4, in which individuals stand on memory foam with eyes closed, and must rely on their vestibular system; therefore, performance in this balance test condition provides a proxy for vestibular function. We looked for balance variations associated with sex, race/ethnicity, health factors, and age. We found that balance test performance was stable between 10 and 39 years of age, with a slight increase in the failure rate for participants 4–9 years of age, suggesting a period of balance development in younger children. For participants 40 years and older, the balance test failure rate increased progressively with age. Diabetes and obesity are the two main health factors we found associated with poor balance, with test condition 4 failure rates of 57 and 19%, respectively. An increase in the odds of having fallen in the last year was associated with a decrease in the time to failure; once individuals dropped below a time to failure of 10 s, there was a significant 5.5-fold increase in the odds of having fallen in the last 12 months. These data alert us to screen for poor vestibular function in individuals 40 years and older or suffering from diabetes, in order to undertake the necessary diagnostic and rehabilitation measures, with a focus on reducing the morbidity and mortality of falls. PMID:29234301

  17. Balance Screening of Vestibular Function in Subjects Aged 4 Years and Older: A Living Laboratory Experience.

    PubMed

    Bermúdez Rey, María Carolina; Clark, Torin K; Merfeld, Daniel M

    2017-01-01

    To better understand the various individual factors that contribute to balance and the relation to fall risk, we performed the modified Romberg Test of Standing Balance on Firm and Compliant Support, with 1,174 participants between 4 and 83 years of age. This research was conducted in the Living Laboratory ® at the Museum of Science, Boston. We specifically focus on balance test condition 4, in which individuals stand on memory foam with eyes closed, and must rely on their vestibular system; therefore, performance in this balance test condition provides a proxy for vestibular function. We looked for balance variations associated with sex, race/ethnicity, health factors, and age. We found that balance test performance was stable between 10 and 39 years of age, with a slight increase in the failure rate for participants 4-9 years of age, suggesting a period of balance development in younger children. For participants 40 years and older, the balance test failure rate increased progressively with age. Diabetes and obesity are the two main health factors we found associated with poor balance, with test condition 4 failure rates of 57 and 19%, respectively. An increase in the odds of having fallen in the last year was associated with a decrease in the time to failure; once individuals dropped below a time to failure of 10 s, there was a significant 5.5-fold increase in the odds of having fallen in the last 12 months. These data alert us to screen for poor vestibular function in individuals 40 years and older or suffering from diabetes, in order to undertake the necessary diagnostic and rehabilitation measures, with a focus on reducing the morbidity and mortality of falls.

  18. Laboratory testing in management of patients with suspected Ebolavirus disease: infection control and safety.

    PubMed

    Gilbert, G L

    2015-08-01

    If routine laboratory safety precautions are followed, the risk of laboratory-acquired infection from handling specimens from patients with Ebolavirus disease (EVD) is very low, especially in the early 'dry' stage of disease. In Australia, border screening to identify travellers returning from EVD-affected west African countries during the 2014-2015 outbreak has made it unlikely that specimens from patients with unrecognised EVD would be sent to a routine diagnostic laboratory. Australian public health and diagnostic laboratories associated with hospitals designated for the care of patients with EVD have developed stringent safety precautions for EVD diagnostic and other tests likely to be required for supportive care of the sickest (and most infectious) patients with EVD, including as wide a range of point-of-care tests as possible. However, it is important that the stringent requirements for packaging, transport and testing of specimens that might contain Ebolavirus--which is a tier 1 security sensitive biology agent--do not delay the diagnosis and appropriate management of other potentially serious but treatable infectious diseases, which are far more likely causes of a febrile illness in people returning from west Africa. If necessary, urgent haematology, biochemistry and microbiological tests can be performed safely, whilst awaiting the results of EVD tests, in a PC-2 laboratory with appropriate precautions including: use of recommended personal protective equipment (PPE) for laboratory staff; handling any unsealed specimens in a class 1 or II biosafety cabinet; using only centrifuges with sealed rotors; and safe disposal or decontamination of all used equipment and laboratory waste.

  19. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... request approval to conduct one or more types of scrapie test or genotype test on one or more types of... type of test and for each type of tissue for which they request approval. (c) The Administrator may... the laboratory and shall give the director an opportunity to respond. If there are conflicts as to any...

  20. Productivity of Veterans Health Administration laboratories: a College of American Pathologists Laboratory Management Index Program (LMIP) study.

    PubMed

    Valenstein, Paul N; Wang, Edward; O'Donohue, Tom

    2003-12-01

    The Veterans Health Administration (VA) operates the largest integrated laboratory network in the United States. To assess whether the unique characteristics of VA laboratories impact efficiency of operations, we compared the productivity of VA and non-VA facilities. Financial and activity data were prospectively collected from 124 VA and 131 non-VA laboratories enrolled in the College of American Pathologists Laboratory Management Index Program (LMIP) during 2002. In addition, secular trends in 5 productivity ratios were calculated for VA and non-VA laboratories enrolled in LMIP from 1997 through 2002. Veterans Health Administration and non-VA facilities did not differ significantly in size. Inpatients accounted for a lower percentage of testing at VA facilities than non-VA facilities (21.7% vs 37.3%; P <.001). Technical staff at the median VA facility were paid more than at non-VA facilities (28.11/h dollars vs 22.60/h dollars, salaries plus benefits; P <.001), VA laboratories employed a smaller percentage of nontechnical staff (30.0% vs 41.9%; P <.001), and workers at VA laboratories worked less time per hour paid (85.5% vs 88.5%; P <.001). However, labor productivity was significantly higher at VA than at non-VA facilities (30 448 test results/total full-time equivalent (FTE)/y vs 19 260 results/total FTE; P <.001), resulting in lower labor expense per on-site test at VA sites than at non-VA sites (1.79 dollars/result vs 2.08 dollars/result; P <.001). Veterans Health Administration laboratories paid less per test for consumables (P =.003), depreciation, and maintenance than their non-VA counterparts (all P <.001), resulting in lower overall cost per on-site test result (2.64 dollars vs 3.40 dollars; P <.001). Cost per referred (sent-out) test did not differ significantly between the 2 groups. Analysis of 6-year trends showed significant increases in both VA (P <.001) and non-VA (P =.02) labor productivity (on-site tests/total FTE). Expenses at VA laboratories

  1. 42 CFR 493.1459 - Condition: Laboratories performing high complexity testing; general supervisor.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; general supervisor. 493.1459 Section 493.1459 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  2. 42 CFR 493.1453 - Condition: Laboratories performing high complexity testing; clinical consultant.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; clinical consultant. 493.1453 Section 493.1453 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  3. 42 CFR 493.1447 - Condition: Laboratories performing high complexity testing; technical supervisor.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; technical supervisor. 493.1447 Section 493.1447 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  4. 42 CFR 493.1459 - Condition: Laboratories performing high complexity testing; general supervisor.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; general supervisor. 493.1459 Section 493.1459 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  5. 42 CFR 493.1447 - Condition: Laboratories performing high complexity testing; technical supervisor.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; technical supervisor. 493.1447 Section 493.1447 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  6. An Alternative to the Physiological Psychology Laboratory: Identification of an Unknown Drug Through Behavioral Testing.

    ERIC Educational Resources Information Center

    Schumacher, Susan J.

    1982-01-01

    A laboratory project introduced physiological psychology students to research by requiring them to identify an unknown drug given to laboratory animals. Students read material about drugs and animal drug studies, designed behavioral tests, constructed the testing apparatus, conducted the tests, and wrote progress reports. (SR)

  7. US Highway 84 chip seal field trials and laboratory test results.

    DOT National Transportation Integrated Search

    2009-03-23

    This report contains laboratory and field testing of US Highway 84 in Lincoln county Mississippi. A full scale field test consisting of seven polymer modified asphalt emulsions and a CRS-2 control emulsion was constructed in September of 1989 and sub...

  8. Study of LTPP laboratory resilient modulus test data and response characteristics.

    DOT National Transportation Integrated Search

    2002-10-01

    The resilient modulus of every unbound structural layer of the Long Term Pavement Performance (LTPP) Specific Pavement and : General Pavement Studies Test Sections is being measured in the laboratory using LTPP test protocol P46. A total of 2,014 : r...

  9. 50 Years of Testing

    NASA Image and Video Library

    2016-04-23

    A 15-second test of a Saturn V rocket stage on the A-2 Test Stand at Stennis Space Center ushered in the Space Age for south Mississippi. Fifty years later, Stennis has grown into the nation’s largest rocket engine test site, continuing to test rocket engines and stages that power the nation’s space program.

  10. Potential over request in anemia laboratory tests in primary care in Spain.

    PubMed

    Salinas, María; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-07-01

    The aim was to study the inter-practice variability in anemia laboratory tests requested by general practitioners in Spain, to evaluate for a potential requesting inappropriateness. Laboratories from diverse Spanish regions filled out the number of cell blood count, ferritin, folate, iron, transferrin, and vitamin B12 requested by general practitioners during 2012. The number of test requests per 1000 inhabitants and ratios of related tests requests were calculated. The results obtained in hospitals from different areas (urban, rural, or urban-rural), type of management (public or private), and geographic regions were compared. There was a high variability in the number of test requests and ratios of related tests. Cell blood count was over requested in rural areas and in hospitals with private management. Andalucía was the community with the lowest number of iron requests and the lowest folate/vitamin B12 indicator value. Iron and transferrin seemed over requested in some areas; as were folate and ferritin when compared to vitamin B12 and cell blood count, respectively. The differences observed between areas indicate that other factors besides clinical reasons could be behind that variability and emphasize the need to accomplish interventions to improve the appropriate use of anemia laboratory tests.

  11. Specimen origin, type and testing laboratory are linked to longer turnaround times for HIV viral load testing in Malawi

    PubMed Central

    Chipungu, Geoffrey; Kim, Andrea A.; Sarr, Abdoulaye; Ali, Hammad; Mwenda, Reuben; Nkengasong, John N.; Singer, Daniel

    2017-01-01

    Background Efforts to reach UNAIDS’ treatment and viral suppression targets have increased demand for viral load (VL) testing and strained existing laboratory networks, affecting turnaround time. Longer VL turnaround times delay both initiation of formal adherence counseling and switches to second-line therapy for persons failing treatment and contribute to poorer health outcomes. Methods We utilized descriptive statistics and logistic regression to analyze VL testing data collected in Malawi between January 2013 and March 2016. The primary outcomes assessed were greater-than-median pretest phase turnaround time (days elapsed from specimen collection to receipt at the laboratory) and greater-than-median test phase turnaround time (days from receipt to testing). Results The median number of days between specimen collection and testing increased 3-fold between 2013 (8 days, interquartile range (IQR) = 6–16) and 2015 (24, IQR = 13–39) (p<0.001). Multivariable analysis indicated that the odds of longer pretest phase turnaround time were significantly higher for specimen collection districts without laboratories capable of conducting viral load tests (adjusted odds ratio (aOR) = 5.16; 95% confidence interval (CI) = 5.04–5.27) as well as for Malawi’s Northern and Southern regions. Longer test phase turnaround time was significantly associated with use of dried blood spots instead of plasma (aOR = 2.30; 95% CI = 2.23–2.37) and for certain testing months and testing laboratories. Conclusion Increased turnaround time for VL testing appeared to be driven in part by categorical factors specific to the phase of turnaround time assessed. Given the implications of longer turnaround time and the global effort to scale up VL testing, addressing these factors via increasing efficiencies, improving quality management systems and generally strengthening the VL spectrum should be considered essential components of controlling the HIV epidemic. PMID:28235013

  12. ASVCP quality assurance guidelines: external quality assessment and comparative testing for reference and in-clinic laboratories.

    PubMed

    Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A

    2015-12-01

    The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.

  13. 78 FR 22536 - Procedural Manual for the Election Assistance Commission's Voting System Test Laboratories...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-16

    ... System Test Laboratories Program Manual, Version 2.0 AGENCY: United States Election Assistance Commission (EAC). ACTION: Notice; publication of Voting System Test Laboratories Program Manual, Version 2.0, for 60 day public comment period on EAC Web site. SUMMARY: The U.S. Election Assistance Commission (EAC...

  14. 75 FR 39954 - Oversight of Laboratory Developed Tests; Public Meeting; Change of Meeting Location

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-13

    ...] Oversight of Laboratory Developed Tests; Public Meeting; Change of Meeting Location AGENCY: Food and Drug... location for the upcoming public meeting entitled ``Oversight of Laboratory Developed Tests.'' A new... the public meeting, FDA is announcing in this notice a new location for the public meeting. II. New...

  15. An examination of the usefulness of repeat testing practices in a large hospital clinical chemistry laboratory.

    PubMed

    Deetz, Carl O; Nolan, Debra K; Scott, Mitchell G

    2012-01-01

    A long-standing practice in clinical laboratories has been to automatically repeat laboratory tests when values trigger automated "repeat rules" in the laboratory information system such as a critical test result. We examined 25,553 repeated laboratory values for 30 common chemistry tests from December 1, 2010, to February 28, 2011, to determine whether this practice is necessary and whether it may be possible to reduce repeat testing to improve efficiency and turnaround time for reporting critical values. An "error" was defined to occur when the difference between the initial and verified values exceeded the College of American Pathologists/Clinical Laboratory Improvement Amendments allowable error limit. The initial values from 2.6% of all repeated tests (668) were errors. Of these 668 errors, only 102 occurred for values within the analytic measurement range. Median delays in reporting critical values owing to repeated testing ranged from 5 (blood gases) to 17 (glucose) minutes.

  16. Automation software for a materials testing laboratory

    NASA Technical Reports Server (NTRS)

    Mcgaw, Michael A.; Bonacuse, Peter J.

    1990-01-01

    The software environment in use at the NASA-Lewis Research Center's High Temperature Fatigue and Structures Laboratory is reviewed. This software environment is aimed at supporting the tasks involved in performing materials behavior research. The features and capabilities of the approach to specifying a materials test include static and dynamic control mode switching, enabling multimode test control; dynamic alteration of the control waveform based upon events occurring in the response variables; precise control over the nature of both command waveform generation and data acquisition; and the nesting of waveform/data acquisition strategies so that material history dependencies may be explored. To eliminate repetitive tasks in the coventional research process, a communications network software system is established which provides file interchange and remote console capabilities.

  17. A Different Laboratory Tale: Fifty Years of Mössbauer Spectroscopy

    NASA Astrophysics Data System (ADS)

    Westfall, Catherine

    2006-05-01

    I explore the fifty-year development of Mössbauer spectroscopy by focusing on three episodes in its development at Argonne National Laboratory: work by nuclear physicists using radioactive sources in the early 1960s, work by solid-state physicists using radioactive resources from the mid- 1960s through the 1970s,and work by solid-state physicists using the Advanced Photon Source from the 1980s to 2005. These episodes show how knowledge about the properties of matter was produced in a national-laboratory context and highlights the web of connections that allow nationallaboratory scientists working at a variety of scales to produce both technological and scientific innovations.

  18. Clinical Variant Classification: A Comparison of Public Databases and a Commercial Testing Laboratory.

    PubMed

    Gradishar, William; Johnson, KariAnne; Brown, Krystal; Mundt, Erin; Manley, Susan

    2017-07-01

    There is a growing move to consult public databases following receipt of a genetic test result from a clinical laboratory; however, the well-documented limitations of these databases call into question how often clinicians will encounter discordant variant classifications that may introduce uncertainty into patient management. Here, we evaluate discordance in BRCA1 and BRCA2 variant classifications between a single commercial testing laboratory and a public database commonly consulted in clinical practice. BRCA1 and BRCA2 variant classifications were obtained from ClinVar and compared with the classifications from a reference laboratory. Full concordance and discordance were determined for variants whose ClinVar entries were of the same pathogenicity (pathogenic, benign, or uncertain). Variants with conflicting ClinVar classifications were considered partially concordant if ≥1 of the listed classifications agreed with the reference laboratory classification. Four thousand two hundred and fifty unique BRCA1 and BRCA2 variants were available for analysis. Overall, 73.2% of classifications were fully concordant and 12.3% were partially concordant. The remaining 14.5% of variants had discordant classifications, most of which had a definitive classification (pathogenic or benign) from the reference laboratory compared with an uncertain classification in ClinVar (14.0%). Here, we show that discrepant classifications between a public database and single reference laboratory potentially account for 26.7% of variants in BRCA1 and BRCA2 . The time and expertise required of clinicians to research these discordant classifications call into question the practicality of checking all test results against a database and suggest that discordant classifications should be interpreted with these limitations in mind. With the increasing use of clinical genetic testing for hereditary cancer risk, accurate variant classification is vital to ensuring appropriate medical management

  19. Clinical pharmacology quality assurance program: models for longitudinal analysis of antiretroviral proficiency testing for international laboratories.

    PubMed

    DiFrancesco, Robin; Rosenkranz, Susan L; Taylor, Charlene R; Pande, Poonam G; Siminski, Suzanne M; Jenny, Richard W; Morse, Gene D

    2013-10-01

    Among National Institutes of Health HIV Research Networks conducting multicenter trials, samples from protocols that span several years are analyzed at multiple clinical pharmacology laboratories (CPLs) for multiple antiretrovirals. Drug assay data are, in turn, entered into study-specific data sets that are used for pharmacokinetic analyses, merged to conduct cross-protocol pharmacokinetic analysis, and integrated with pharmacogenomics research to investigate pharmacokinetic-pharmacogenetic associations. The CPLs participate in a semiannual proficiency testing (PT) program implemented by the Clinical Pharmacology Quality Assurance program. Using results from multiple PT rounds, longitudinal analyses of recovery are reflective of accuracy and precision within/across laboratories. The objectives of this longitudinal analysis of PT across multiple CPLs were to develop and test statistical models that longitudinally: (1) assess the precision and accuracy of concentrations reported by individual CPLs and (2) determine factors associated with round-specific and long-term assay accuracy, precision, and bias using a new regression model. A measure of absolute recovery is explored as a simultaneous measure of accuracy and precision. Overall, the analysis outcomes assured 97% accuracy (±20% of the final target concentration of all (21) drug concentration results reported for clinical trial samples by multiple CPLs). Using the Clinical Laboratory Improvement Act acceptance of meeting criteria for ≥2/3 consecutive rounds, all 10 laboratories that participated in 3 or more rounds per analyte maintained Clinical Laboratory Improvement Act proficiency. Significant associations were present between magnitude of error and CPL (Kruskal-Wallis P < 0.001) and antiretroviral (Kruskal-Wallis P < 0.001).

  20. GATE AND VACUUM FLUSHING OF SEWER SEDIMENT: LABORATORY TESTING

    EPA Science Inventory

    The objective of this study was to test the performance of a traditional gate-flushing device and a newly-designed vacuum-flushing device in removing sediment from combined sewers and CSO storage tanks. A laboratory hydraulic flume was used to simulate a reach of sewer or storag...

  1. Single Event Effects Test Facility Options at the Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riemer, Bernie; Gallmeier, Franz X; Dominik, Laura J

    2015-01-01

    Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of integrated circuits (ICs) and systems for use in radiationmore » environments requires the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.« less

  2. Combined ultraviolet and water exposure as a preconditioning method in laboratory fungal durability testing

    Treesearch

    Rebecca E. Ibach; Craig M. Clemons; Nicole M. Stark

    2003-01-01

    During outdoor exposure, woodfiber-plastic composites (WPC) are subject to biological, moisture, and ultraviolet (UV) degradation. The purpose of laboratory evaluations is to simulate outdoor conditions and accelerate the testing for quicker results. Traditionally, biological, moisture, and W laboratory tests are done separately, and only combined in outdoor field...

  3. [What's the point of cost management in clinical laboratories?].

    PubMed

    Setoyama, Tomokazu; Yamauchi, Kazuyoshi; Katsuyama, Tsutomu

    2006-11-01

    Clinical laboratories need to know and manage the costs of laboratory tests, because they need financial data (1) to estimate costs per patient, (2) to request a budget to buy equipment, and (3) to improve their work; however, less than 40% laboratories practice cost management. In 2002, Shinshu University Hospital began to assess the costs of laboratory tests, but it was difficult to evaluate the quality of our cost management because there are few data and papers about the costs of laboratory tests in Japan. In this article, we practiced cost analysis using Shinshu University Hospital's data for 3 years (2002-2004), and studied the features of laboratory test costs and the problems of laboratory cost management. As a result, we listed 7 points to check cost management in clinical laboratories. This check list was established using only one data from our hospital. So, we suggest the benchmarking laboratory test costs between laboratories of the same type of hospitals or various laboratories.

  4. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.

    PubMed

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-02-15

    Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.

  5. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia

    PubMed Central

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-01-01

    Introduction Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. Materials and methods EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Results Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Conclusion Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level. PMID:28392735

  6. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...

  7. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...

  8. Preventing Boredom in the Language Laboratory

    ERIC Educational Resources Information Center

    Obanya, Pai

    1978-01-01

    An experimental year of oral testing using the language laboratory at Victoria University is described. A new first-year 12-credit course is primarily a language course based on audiovisual/lingual methods. The content, evaluation, and administration of oral expression tests and performance tapes are covered. (SW)

  9. A Unique Testing System for Audio Visual Foreign Language Laboratory.

    ERIC Educational Resources Information Center

    Stama, Spelios T.

    1980-01-01

    Described is the design of a low maintenance, foreign language laboratory at Ithaca College, New York, that provides visual and audio instruction, flexibility for testing, and greater student involvement in the lessons. (Author/CS)

  10. National Media Laboratory media testing results

    NASA Technical Reports Server (NTRS)

    Mularie, William

    1993-01-01

    The government faces a crisis in data storage, analysis, archive, and communication. The sheer quantity of data being poured into the government systems on a daily basis is overwhelming systems ability to capture, analyze, disseminate, and store critical information. Future systems requirements are even more formidable: with single government platforms having data rate of over 1 Gbit/sec, greater than Terabyte/day storage requirements, and with expected data archive lifetimes of over 10 years. The charter of the National Media Laboratory (NML) is to focus the resources of industry, government, and academia on government needs in the evaluation, development, and field support of advanced recording systems.

  11. The quality and scope of information provided by medical laboratories to patients before laboratory testing: Survey of the Working Group for Patient Preparation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Nikolac, Nora; Simundic, Ana-Maria; Kackov, Sanja; Serdar, Tihana; Dorotic, Adrijana; Fumic, Ksenija; Gudasic-Vrdoljak, Jelena; Klenkar, Kornelija; Sambunjak, Jadranka; Vidranski, Valentina

    2015-10-23

    The aim of this work was to evaluate to what extent the scope and content of information provided to patients is standardized across medical biochemistry laboratories in Croatia. Two on-line self-report surveys were sent out: Survey A regarding attitudes on importance of patient preparation and Survey B on the contents of patient preparation instructions. 13/118 laboratories (11%) do not provide written instructions to patients on how to prepare for laboratory testing, and 36 (40%) do not include information about water intake in their instructions. Only half of laboratories provide instructions for prostate-specific antigen (53.8%), female sex hormones (53.7%) and therapeutic drug monitoring (TDM) (52.5%). Inadequate information about fasting status (55.0%) and 24 hour urine collection (77.9%) were frequent errors with high severity and were associated with the greatest potential to cause patient harm. Laboratory professionals in Croatia have a positive attitude towards the importance of patient preparation for laboratory testing. However, the information for laboratory testing is not standardized and frequently lacks guidance for tests related to TDM, coagulation and endocrinology. This study highlights the need for standardized, updated and evidence-based recommendations for patient preparation in order to minimize the risk for patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. CERTS Microgrid Laboratory Test Bed - PIER Final Project Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eto, Joseph H.; Eto, Joseph H.; Lasseter, Robert

    2008-07-25

    The objective of the CERTS Microgrid Laboratory Test Bed project was to enhance the ease of integrating small energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; 2) an approach to electrical protection within the microgrid that does not depend on highmore » fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications. The techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers 1547 and power quality requirements. The electrical protections system was able to distinguish between normal and faulted operation. The controls were found to be robust and under all conditions, including difficult motor starts. The results from these test are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or mroe of the CERTS Microgrid concepts.« less

  13. 75 FR 17281 - Changes in Hourly Fee Rates for Science and Technology Laboratory Services-Fiscal Years 2010-2012

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-06

    ..., residue chemistry, proximate analysis for composition, and biomolecular (DNA-based) testing. A user fee... provide greater clarity of reported test analyses and laboratory determinations. DATES: Effective April 7... analyses and laboratory determinations provided by AMS laboratory services apply only to the submitted...

  14. Geographically distributed hybrid testing & collaboration between geotechnical centrifuge and structures laboratories

    NASA Astrophysics Data System (ADS)

    Ojaghi, Mobin; Martínez, Ignacio Lamata; Dietz, Matt S.; Williams, Martin S.; Blakeborough, Anthony; Crewe, Adam J.; Taylor, Colin A.; Madabhushi, S. P. Gopal; Haigh, Stuart K.

    2018-01-01

    Distributed Hybrid Testing (DHT) is an experimental technique designed to capitalise on advances in modern networking infrastructure to overcome traditional laboratory capacity limitations. By coupling the heterogeneous test apparatus and computational resources of geographically distributed laboratories, DHT provides the means to take on complex, multi-disciplinary challenges with new forms of communication and collaboration. To introduce the opportunity and practicability afforded by DHT, here an exemplar multi-site test is addressed in which a dedicated fibre network and suite of custom software is used to connect the geotechnical centrifuge at the University of Cambridge with a variety of structural dynamics loading apparatus at the University of Oxford and the University of Bristol. While centrifuge time-scaling prevents real-time rates of loading in this test, such experiments may be used to gain valuable insights into physical phenomena, test procedure and accuracy. These and other related experiments have led to the development of the real-time DHT technique and the creation of a flexible framework that aims to facilitate future distributed tests within the UK and beyond. As a further example, a real-time DHT experiment between structural labs using this framework for testing across the Internet is also presented.

  15. Vestibular Migraine in Children and Adolescents: Clinical Findings and Laboratory Tests

    PubMed Central

    Langhagen, Thyra; Lehrer, Nicole; Borggraefe, Ingo; Heinen, Florian; Jahn, Klaus

    2015-01-01

    Introduction: Vestibular migraine (VM) is the most common cause of episodic vertigo in children. We summarize the clinical findings and laboratory test results in a cohort of children and adolescents with VM. We discuss the limitations of current classification criteria for dizzy children. Methods: A retrospective chart analysis was performed on 118 children with migraine related vertigo at a tertiary care center. Patients were grouped in the following categories: (1) definite vestibular migraine (dVM); (2) probable vestibular migraine (pVM); (3) suspected vestibular migraine (sVM); (4) benign paroxysmal vertigo (BPV); and (5) migraine with/without aura (oM) plus vertigo/dizziness according to the International Classification of Headache Disorders, 3rd edition (beta version). Results: The mean age of all patients was 12 ± 3 years (range 3–18 years, 70 females). 36 patients (30%) fulfilled criteria for dVM, 33 (28%) for pVM, 34 (29%) for sVM, 7 (6%) for BPV, and 8 (7%) for oM. Somatoform vertigo (SV) co-occurred in 27% of patients. Episodic syndromes were reported in 8%; the family history of migraine was positive in 65%. Mild central ocular motor signs were found in 24% (most frequently horizontal saccadic pursuit). Laboratory tests showed that about 20% had pathological function of the horizontal vestibulo-ocular reflex, and almost 50% had abnormal postural sway patterns. Conclusion: Patients with definite, probable, and suspected VM do not differ in the frequency of ocular motor, vestibular, or postural abnormalities. VM is the best explanation for their symptoms. It is essential to establish diagnostic criteria in clinical studies. In clinical practice, however, the most reasonable diagnosis should be made in order to begin treatment. Such a procedure also minimizes the fear of the parents and children, reduces the need to interrupt leisure time and school activities, and prevents the development of SV. PMID:25674076

  16. Interlaboratory comparison of test results for detection of Lyme disease by 516 participants in the Wisconsin State Laboratory of Hygiene/College of American Pathologists Proficiency Testing Program.

    PubMed Central

    Bakken, L L; Callister, S M; Wand, P J; Schell, R F

    1997-01-01

    In 1991, we reported that 55% of laboratories participating in the Wisconsin Proficiency Testing Program could not accurately identify serum samples from Lyme disease patients containing antibody against Borrelia burgdorferi. The purpose of this study was to determine whether the accuracy of Lyme disease test results reported by approximately 500 participants in the Wisconsin State Laboratory of Hygiene/College of American Pathologists Lyme Disease Survey had improved. From 1992 through 1994, 50 serum samples were sent to participants of the survey. Each laboratory received 28 serum samples from individuals with Lyme disease according to the case definition of the Centers for Disease Control and Prevention and 22 serum samples from healthy individuals. Unfortunately, the serodiagnosis of Lyme disease by participants had not improved. The specificity of the Lyme disease assays steadily decreased from approximately 95% to approximately 81% during the 3-year period of the survey. False-positive test results approached 55% with some of the serum samples from healthy donors. A serum sample containing antibody against Treponema pallidum was reported as positive by 70% of the participants. In addition, the sensitivity fluctuated between 93 and 75%, depending upon the conjugate used by the laboratories. These results suggest that stronger criteria must be applied for approving and continuing to approve commercially available kits for the serodiagnosis of Lyme disease. PMID:9041384

  17. Development, integrated investigation, laboratory and in-flight testing of Chibis-M microsatellite ADCS

    NASA Astrophysics Data System (ADS)

    Ovchinnikov, M. Yu.; Ivanov, D. S.; Ivlev, N. A.; Karpenko, S. O.; Roldugin, D. S.; Tkachev, S. S.

    2014-01-01

    Design, analytical investigation, laboratory and in-flight testing of the attitude determination and control system (ADCS) of a microsatellites are considered. The system consists of three pairs of reaction wheels, three magnetorquers, a set of Sun sensors, a three-axis magnetometer and a control unit. The ADCS is designed for a small 10-50 kg LEO satellite. System development is accomplished in several steps: satellite dynamics preliminary study using asymptotical and numerical techniques, hardware and software design, laboratory testing of each actuator and sensor and the whole ADCS. Laboratory verification is carried out on the specially designed test-bench. In-flight ADCS exploitation results onboard the Russian microsatellite "Chibis-M" are presented. The satellite was developed, designed and manufactured by the Institute of Space Research of RAS. "Chibis-M" was launched by the "Progress-13M" cargo vehicle on January 25, 2012 after undocking from the International Space Station (ISS). This paper assess both the satellite and the ADCS mock-up dynamics. Analytical, numerical and laboratory study results are in good correspondence with in-flight data.

  18. An electronic thesaurus of Evidence Based Laboratory Medicine hematological and biochemical diagnostic tests.

    PubMed

    Dorizzi, R M; Maconi, M; Giavarina, D; Loza, G; Aman, M; Moreira, J; Bisoffi, Z; Gennuso, C

    2009-10-01

    The adoption of Evidence Based Laboratory Medicine (EBLM) has been hampered until today by the lack of effective tools. The SIMeL EBLM e-Thesaurus (on-line Repertoire of the diagnostic effectiveness of the laboratory, radiology and cardiology test) provides a useful support to clinical laboratory professionals and to clinicians for the interpretation of the diagnostic tests. The e-Thesaurus is an application developed using Microsoft Active Server Pages technology and carried out with Web Server Microsoft Internet Information Server and is available at the SIMeL website using a browser running JavaScript scripts (Internet Explorer is recommended). It contains a database (in Italian, English and Spanish) of the sensitivity and specificity (including the 95% confidence interval), the positive and negative likelihood ratios, the Diagnostic Odds Ratio and the Number Needed to Diagnose of more than 2000 diagnostic (most laboratory but also cardiology and radiology) tests. The e-Thesaurus improves the previous SIMeL paper and CD Thesaurus; its main features are a three languages search and a continuous and an easy updating capability.

  19. Laboratories | NREL

    Science.gov Websites

    | Z A Accelerated Exposure Testing Laboratory Advanced Optical Materials Laboratory Advanced Thermal Laboratory Structural Testing Laboratory Surface Analysis Laboratory Systems Performance Laboratory T Thermal Storage Materials Laboratory Thermal Storage Process and Components Laboratory Thin-Film Deposition

  20. Urinary lithogenesis risk tests: comparison of a commercial kit and a laboratory prototype test.

    PubMed

    Grases, Félix; Costa-Bauzá, Antonia; Prieto, Rafel M; Arrabal, Miguel; De Haro, Tomás; Lancina, Juan A; Barbuzano, Carmen; Colom, Sergi; Riera, Joaquín; Perelló, Joan; Isern, Bernat; Sanchis, Pilar; Conte, Antonio; Barragan, Fernando; Gomila, Isabel

    2011-11-01

    Renal stone formation is a multifactorial process depending in part on urine composition. Other parameters relate to structural or pathological features of the kidney. To date, routine laboratory estimation of urolithiasis risk has been based on determination of urinary composition. This process requires collection of at least two 24 h urine samples, which is tedious for patients. The most important feature of urinary lithogenic risk is the balance between various urinary parameters, although unknown factors may be involved. The objective of this study was to compare data obtained using a commercial kit with those of a laboratory prototype, using a multicentre approach, to validate the utility of these methods in routine clinical practice. A simple new commercial test (NefroPlus®; Sarstedt AG & Co., Nümbrecht, Germany) evaluating the capacity of urine to crystallize calcium salts, and thus permitting detection of patients at risk for stone development, was compared with a prototype test previously described by this group. Urine of 64 volunteers produced during the night was used in these comparisons. The commercial test was also used to evaluate urine samples of 83 subjects in one of three hospitals. Both methods were essentially in complete agreement (98%) with respect to test results. The multicentre data were: sensitivity 94.7%; specificity 76.9%; positive predictive value (lithogenic urine) 90.0%; negative predictive value (non-lithogenic urine) 87.0%; test efficacy 89.2%. The new commercial NefroPlus test offers fast and cheap evaluation of the overall risk of development of urinary calcium-containing calculi.

  1. Estrogen and progesterone receptor testing in breast carcinoma: concordance of results between local and reference laboratories in Brazil.

    PubMed

    Wludarski, Sheila Cristina Lordelo; Lopes, Lisandro Ferreira; Duarte, Ivison Xavier; Carvalho, Filomena Marino; Weiss, Lawrence; Bacchi, Carlos Eduardo

    2011-01-01

    Breast cancer accounts for approximately one quarter of all cancers in females. Estrogen and progesterone receptor testing has become an essential part of the clinical evaluation of breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from hormone therapy. The present study had the aim of investigating the concordance of the results from hormone receptor tests between a reference laboratory and local (or community) laboratories in Brazil. Retrospective study at a reference pathology laboratory. The concordance in the results from hormone receptor tests between a reference laboratory and 146 local laboratories in Brazil was compared in relation to 500 invasive breast carcinoma cases, using immunohistochemistry. There was concordance in 89.4% (447/500 cases) and 85.0% (425/500 cases) of the results from estrogen (κ = 0.744, P < 0.001) and progesterone (κ = 0.688, P < 0.001) receptor tests, respectively, between local and reference laboratories. This was similar to findings in other countries. The false negative rates from estrogen and progesterone receptor tests in local laboratories were 8.7% and 14.4%, respectively. The false positive rates from estrogen and progesterone receptor tests in local laboratories were 15.5% and 16.0%, respectively. Technical and result interpretation issues may explain most of the discordances in hormone receptor testing in local laboratories. Validation of estrogen and progesterone receptor tests at local laboratories, with rigorous quality control measures, is strongly recommended in order to avoid erroneous treatment of breast cancer patients.

  2. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds.

    PubMed

    Frank, Jared A; Brill, Anthony; Kapila, Vikram

    2016-08-20

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability.

  3. Second United States Microgravity Laboratory: One Year Report. Volume 1

    NASA Technical Reports Server (NTRS)

    Vlasse, M (Editor); McCauley, D. (Editor); Walker, C. (Editor)

    1998-01-01

    This document reports the one year science results for the important and highly successful Second United States Microgravity Laboratory (USML-2). The USML-2 mission consisted of a pressurized Spacelab module where the crew performed experiments. The mission also included a Glovebox where the crew performed additional experiments for the investigators. Together, about 36 major scientific experiments were performed, advancing the state of knowledge in fields such as fluid physics, solidification of metals, alloys, and semiconductors, combustion, and the growth of protein crystals. The results demonstrate the range of quality science that can be conducted utilizing orbital laboratories in microgravity and provide a look forward to a highly productive Space Station era.

  4. Second United States Microgravity Laboratory: One Year Report. Volume 2

    NASA Technical Reports Server (NTRS)

    Vlasse, M. (Editor); McCauley, D. (Editor); Walker, C. (Editor)

    1998-01-01

    This document reports the one year science results for the important and highly successful Second United States Microgravity Laboratory (USML-2). The USML-2 mission consisted of a pressurized Spacelab module where the crew performed experiments. The mission also included a Glovebox where the crew performed additional experiments for the investigators. Together, about 36 major scientific experiments were performed, advancing the state of knowledge in fields such as fluid physics, solidification of metals, alloys, and semiconductors, combustion, and the growth of protein crystals. The results demonstrate the range of quality science that can be conducted utilizing orbital laboratories in microgravity and provide a look forward to a highly productive Space Station era.

  5. Comparison of basic laboratory test results with more sophisticated laboratory and in-situ tests methods on soils in southeastern Wisconsin : final report, March 21, 2009.

    DOT National Transportation Integrated Search

    2009-03-21

    This study investigates all of the generated soils data in an attempt to use the more 'routine' laboratory tests to determine geotechnical design parameters (such as phiangle, cohesion, wet unit weight, unconfined compression, consolidation character...

  6. Testing the performance of microbiological safety cabinets used in microbiology laboratories in South Korea.

    PubMed

    Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S

    2011-09-01

    To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  7. [Revolution of the health care delivery system and its impacts on laboratory testing in the United States].

    PubMed

    Takemura, Y; Ishibashi, M

    2000-02-01

    Failure to slow the exponential growth of total health care expenditures in the United States through the government policies resulted in a rapid and progressive penetration of managed care organizations(MCOs) in the early 1990s. Diagnostic testing is viewed as a "commodity" rather than a medical service under the managed care environment. Traditional hospital-based laboratories are placed in a downward spiral with the advent of managed care era. A massive reduction of in-house testing resulted from shorter lengths of patients' hospital stay and a marked decrease in admission under the dominance of managed care urges them to develop strategies for restoring tests deprived by the managed care-associated new businesses: consolidation and networking, participation in the outreach-testing market, and point-of-care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for survival of hospital laboratories. A number of physicians' office laboratories(POLs) have been closed owing to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988(CLIA '88), and to the expanded penetration of MCOs which limit reimbursement to a very few in-house procedures. It seems likely that POLs and hospital laboratories continue to reduce test volumes, while commercial reference laboratories(CRLs) gain more tests through contracting with MCOs. In the current stream of managed care dominance in the United States, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Traditional laboratories which are unwilling to adapt themselves to the new environment will not survive in this country.

  8. External quality assessment for arbovirus diagnostics in the World Health Organization Western Pacific Region, 2013–2016: improving laboratory quality over the years

    PubMed Central

    Abdad, Mohammad Yazid; Squires, Raynal C; Cognat, Sebastien; Oxenford, Christopher John

    2017-01-01

    Arboviruses continue to pose serious public health threats in the World Health Organization (WHO) Western Pacific Region. As such, laboratories need to be equipped for their accurate detection. In 2011, to ensure test proficiency, the WHO Regional Office for the Western Pacific piloted an external quality assessment (EQA) programme for arbovirus diagnostics. By 2016, it had grown into a global programme with participation of 96 laboratories worldwide, including 25 laboratories from 19 countries, territories and areas in the Region. The test performance of the 25 laboratories in the Region in 2016 was high with 23 (92%) reporting correct results in all specimens for dengue and chikungunya viruses. For Zika virus, 18 (72%) of the 25 laboratories reported correct results in all specimens, while seven (28%) demonstrated at least one error. When comparing iterations of this EQA programme in the Region between 2013 and 2016, the number of participating laboratories increased from 18 to 25. The first round only included dengue virus, while the latest round additionally included chikungunya, Zika and yellow fever viruses. Proficiency for molecular detection of dengue virus remained high (83–94%) over the four-year period. The observed proficiency for arbovirus diagnostics between 2013 and 2016 is an indicator of laboratory quality improvement in the Region. PMID:29051839

  9. Proficiency Testing Activities of Frequency Calibration Laboratories in Taiwan, 2009

    DTIC Science & Technology

    2009-11-01

    cht.com.tw Abstract In order to meet the requirements of ISO 17025 and the demand of TAF (Taiwan Accreditation Foundation) for calibration inter... IEC 17025 General requirements for the competence of testing and calibration laboratories. The proficiency testing results are then important...on-site evaluation, an assessment team is organized to examine the technical competence of the labs and their compliance with the requirements of ISO

  10. Testing painted wood : past practices at the Forest Products Laboratory and recommendations for future research

    Treesearch

    R. Sam Williams

    2009-01-01

    A brief history of paint research at the Forest Products Laboratory (FPL) in Madison, Wisconsin, sets the stage for a discussion of testing paint on wood and wood products. Tests include laboratory and outdoor tests, and I discuss them in terms of several degradation mechanisms (loss of gloss and fading, mildew growth, extractives bleed, and cracking, flaking, and...

  11. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Approval of laboratories to run official scrapie tests and official genotype tests. 54.11 Section 54.11 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF...

  12. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  13. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  14. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  15. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  16. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Approval of laboratories to run official scrapie tests and official genotype tests. 54.11 Section 54.11 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF...

  17. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF CHRONIC...

  18. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Approval of laboratories to run official scrapie tests and official genotype tests. 54.11 Section 54.11 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF...

  19. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Approval of laboratories to run official scrapie tests and official genotype tests. 54.11 Section 54.11 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE COOPERATIVE CONTROL AND ERADICATION OF LIVESTOCK OR POULTRY DISEASES CONTROL OF...

  20. Validation of laboratory-scale recycling test method of paper PSA label products

    Treesearch

    Carl Houtman; Karen Scallon; Richard Oldack

    2008-01-01

    Starting with test methods and a specification developed by the U.S. Postal Service (USPS) Environmentally Benign Pressure Sensitive Adhesive Postage Stamp Program, a laboratory-scale test method and a specification were developed and validated for pressure-sensitive adhesive labels, By comparing results from this new test method and pilot-scale tests, which have been...

  1. Achieving continuous improvement in laboratory organization through performance measurements: a seven-year experience.

    PubMed

    Salinas, Maria; López-Garrigós, Maite; Gutiérrez, Mercedes; Lugo, Javier; Sirvent, Jose Vicente; Uris, Joaquin

    2010-01-01

    Laboratory performance can be measured using a set of model key performance indicators (KPIs). The design and implementation of KPIs are important issues. KPI results from 7 years are reported and their implementation, monitoring, objectives, interventions, result reporting and delivery are analyzed. The KPIs of the entire laboratory process were obtained using Laboratory Information System (LIS) registers. These were collected automatically using a data warehouse application, spreadsheets and external quality program reports. Customer satisfaction was assessed using surveys. Nine model laboratory KPIs were proposed and measured. The results of some examples of KPIs used in our laboratory are reported. Their corrective measurements or the implementation of objectives led to improvement in the associated KPIs results. Measurement of laboratory performance using KPIs and a data warehouse application that continuously collects registers and calculates KPIs confirmed the reliability of indicators, indicator acceptability and usability for users, and continuous process improvement.

  2. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories.

    PubMed

    Koenen, F; Uttenthal, A; Meindl-Böhmer, A

    2007-12-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning contingency plans. These plans should ensure that in the event of an outbreak access to facilities, equipment, resources, trained personnel, and all other facilities needed for the rapid and efficient eradication of the outbreak is guaranteed, and that the procedures to follow are well rehearsed. It is essential that these plans are established during 'peace-time' and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance of a well-documented laboratory contingency plan. The major pitfalls encountered were shortage of space, difficulties in guaranteeing biosecurity and sufficient supplies of sterile equipment and consumables. The need for a standardised laboratory information management system, that is used by all those involved in order to reduce the administrative load, is also discussed.

  3. From laboratory corrosion tests to a corrosion lifetime for wood fasteners : progress and challenges

    Treesearch

    Samuel L. Zelinka; Dominique Derome; Samuel V. Glass

    2010-01-01

    Determining a “corrosion-lifetime” for fasteners embedded in wood treated with recently adopted preservative systems depends upon successfully relating results of laboratory tests to in-service conditions. In contrast to laboratory tests where metal is embedded in wood at constant temperature and moisture content, the in-service temperature and moisture content of wood...

  4. Trends in testing behaviours for hepatitis C virus infection and associated determinants: results from population-based laboratory surveillance in Alberta, Canada (1998-2001).

    PubMed

    Jayaraman, G C; Lee, B; Singh, A E; Preiksaitis, J K

    2007-04-01

    Little is currently known about hepatitis C virus (HCV) test seeking behaviours at the population level. Given the centralized nature of testing for HCV infection in the province of Alberta, Canada, we had an opportunity to examine HCV testing behaviour at the population level on all newly diagnosed HCV-positive cases using laboratory data to validate the time and number of prior tests for each case. Record linkage identified 3323, 2937, 2660 and 2703 newly diagnosed cases of HCV infections in Alberta during 1998, 1999, 2000 and 2001, respectively, corresponding to age-adjusted rates of 149.8, 129, 114.3 and 113.7 per 100,000 population during these years, respectively. Results from secondary analyses of laboratory data suggest that the majority of HCV cases (95.3%) who were newly diagnosed between 1998 and 2001 were first-time testers for HCV infection. Among repeat testers, analysis of a negative test result within 1 year prior to a first of a positive test report suggests that 211 (38.4%) may be seroconvertors. These findings suggest that 339 or 61.7% of repeat testers may not have discovered their serostatus within 1 year of infection. Among this group, HCV testing was sought infrequently, with a median interval of 2.3 years between the last negative and first positive test. This finding is of concern given the risks for HCV transmission, particularly if risk-taking behaviours are not reduced because of unknown serostatus. These findings also reinforce the need to make the most of each test-seeking event with proper counselling and other appropriate support services.

  5. Clinical utility of routine laboratory testing to identify possible secondary causes in older men with osteoporosis: the Osteoporotic Fractures in Men (MrOS) Study

    PubMed Central

    Fink, Howard A.; Litwack-Harrison, Stephanie; Taylor, Brent C.; Bauer, Douglas C.; Orwoll, Eric S.; Lee, Christine G.; Barrett-Connor, Elizabeth; Schousboe, John T.; Kado, Deborah M.; Garimella, Pranav S.; Ensrud, Kristine E.

    2016-01-01

    Purpose To evaluate the utility of recommended laboratory testing to identify secondary causes in older men with osteoporosis, we examined prevalence of laboratory abnormalities in older men with and without osteoporosis. Methods 1572 men aged ≥65 years in the Osteoporotic Fractures in Men study completed bone mineral density (BMD) testing and a battery of laboratory measures, including serum calcium, phosphorus, alkaline phosphatase, parathyroid hormone (PTH), thyroid-stimulating hormone (TSH), 25-OH vitamin D, total testosterone, spot urine calcium/creatinine ratio, spot urine albumin-creatinine ratio, creatinine-derived estimate glomerular filtration rate, 24-hour urine calcium, and 24-hour urine free cortisol. Using cross-sectional analyses, we calculated prevalence ratios (PR) and 95% confidence intervals (CI) for the association of any and specific laboratory abnormalities with osteoporosis, and the number of men with osteoporosis needed to test to identify one additional laboratory abnormality compared to testing men without osteoporosis. Results Approximately 60% of men had ≥1 laboratory abnormality in both men with and without osteoporosis. Among individual tests, only vitamin D insufficiency (PR, 1.13; 95% CI, 1.05–1.22) and high alkaline phosphatase (PR, 3.05; 95% CI, 1.52–6.11) were more likely in men with osteoporosis. Hypercortisolism and hyperthyroidism were uncommon and not significantly more frequent in men with osteoporosis. No osteoporotic men had hypercalciuria. Conclusions Though most of these older men had ≥1 laboratory abnormality, few routinely recommended individual tests were more common in men with osteoporosis than in those without osteoporosis. Possibly excepting vitamin D and alkaline phosphatase, benefit of routine laboratory testing to identify possible secondary causes in older osteoporotic men appears low. Results may not be generalizable to younger men or to older men in whom history and exam findings raise clinical

  6. 2016 Annual Site Environmental report Sandia National Laboratories Tonopah Test Range Nevada & Kaua'i Test Facility Hawai'i.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salas, Angela Maria; Griffith, Stacy R.

    Sandia National Laboratories (SNL) is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s (DOE’s), National Nuclear Security Administration (NNSA) under contract DE-NA0003525. The DOE/NNSA Sandia Field Office administers the contract and oversees contractor operations at the SNL, Tonopah Test Range (SNL/TTR) in Nevada and the SNL, Kaua‘i Test Facility (SNL/KTF) in Hawai‘i. SNL personnel manage and conduct operations at SNL/TTR in support of the DOE/NNSA’s Weapons Ordnance Program and have operated the site since 1957. Navarro Research and Engineeringmore » personnel perform most of the environmental programs activities at SNL/TTR. The DOE/NNSA/Nevada Field Office retains responsibility for cleanup and management of SNL/TTR Environmental Restoration sites. SNL personnel operate SNL/KTF as a rocket preparation launching and tracking facility. This Annual Site Environmental Report (ASER) summarizes data and the compliance status of sustainability, environmental protection, and monitoring programs at SNL/TTR and SNL/KTF during calendar year 2016. Major environmental programs include air quality, water quality, groundwater protection, terrestrial and biological surveillance, waste management, pollution prevention, environmental restoration, oil and chemical spill prevention, and implementation of the National Environmental Policy Act. This ASER is prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety, and Health Reporting.« less

  7. SPHINX Satellite Testing in the Electric Propulsion Laboratory

    NASA Image and Video Library

    1973-12-21

    Researchers examine the Space Plasma-High Voltage Interaction Experiment (SPHINX) satellite in the Electric Propulsion Laboratory at the National Aeronautics and Space Administration (NASA) Lewis Research Center. Lewis’ Spacecraft Technology Division designed SPHINX to study the electrical interaction of its experimental surfaces with space plasma. They sought to determine if higher orbits would improve the transmission quality of communications satellites. Robert Lovell, the Project Manager, oversaw vibrational and plasma simulation testing of the satellite in the Electric Propulsion Laboratory, seen here. SPHINX was an add-on payload for the first Titan/Centaur proof launch in early 1974. Lewis successfully managed the Centaur Program since 1962, but this would be the first Centaur launch with a Titan booster. Since the proof test did not have a scheduled payload, the Lewis-designed SPHINX received a free ride. The February 11, 1974 launch, however, proved to be one of the Launch Vehicle Division’s lowest days. Twelve minutes after the vehicle departed the launch pad, the booster and Centaur separated as designed, but Centaur’s two RL-10 engines failed to ignite. The launch pad safety officer destroyed the vehicle, and SPHINX never made it into orbit. Overall Centaur has an excellent success rate, but the failed SPHINX launch attempt caused deep disappointment across the center.

  8. Implications of the introduction of laboratory demand management at primary care clinics in South Africa on laboratory expenditure

    PubMed Central

    Lekalakala, Ruth; Asmall, Shaidah; Cassim, Naseem

    2016-01-01

    Background Diagnostic health laboratory services are regarded as an integral part of the national health infrastructure across all countries. Clinical laboratory tests contribute substantially to health system goals of increasing quality of care and improving patient outcomes. Objectives This study aimed to analyse current laboratory expenditures at the primary healthcare (PHC) level in South Africa as processed by the National Health Laboratory Service and to determine the potential cost savings of introducing laboratory demand management. Methods A retrospective cross-sectional analysis of laboratory expenditures for the 2013/2014 financial year across 11 pilot National Health Insurance health districts was conducted. Laboratory expenditure tariff codes were cross-tabulated to the PHC essential laboratory tests list (ELL) to determine inappropriate testing. Data were analysed using a Microsoft Access database and Excel software. Results Approximately R35 million South African Rand (10%) of the estimated R339 million in expenditures was for tests that were not listed within the ELL. Approximately 47% of expenditure was for laboratory tests that were indicated in the algorithmic management of patients on antiretroviral treatment. The other main cost drivers for non-ELL testing included full blood count and urea, as well as electrolyte profiles usually requested to support management of patients on antiretroviral treatment. Conclusions Considerable annual savings of up to 10% in laboratory expenditure are possible at the PHC level by implementing laboratory demand management. In addition, to achieve these savings, a standardised PHC laboratory request form and some form of electronic gatekeeping system that must be supported by an educational component should be implemented. PMID:28879107

  9. Princeton Plasma Physics Laboratory Annual Site Environmental Report for Calendar Year 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J.D. Levine; V.L. Finley

    1998-03-01

    The results of the 1996 environmental surveillance and monitoring program for the Princeton Plasma Physics Laboratory (PPPL) are presented and discussed. The purpose of this report is to provide the US Department of Energy and the public with information on the level of radioactive and nonradioactive pollutants, if any, that are added to the environment as a result of PPPL's operations. During Calendar Year 1996, PPPL's Tokamak Fusion Test Reactor (TFTR) continued to conduct fusion experiments. Having set a world record on November 2, 1994, by achieving approximately 10.7 million watts of controlled fusion power during the deuterium-tritium (D-T) plasmamore » experiments, researchers turned their attention to studying plasma science experiments, which included ''enhanced reverse shear techniques.'' Since November 1993, more than 700 tritium-fueled experiments were conducted, which generated more than 4 x 10(superscript 20) neutrons and 1.4 gigajoules of fusion energy. In 1996, the overall performance of Princeton Plasma Physics Laboratory was rated ''excellent'' by the US Department of Energy in the Laboratory Appraisal report issued in early 1997. The report cited the Laboratory's consistently excellent scientific and technological achievements and its successful management practices, which included high marks for environmental management, employee health and safety, human resources administration, science education, and communications. Groundwater investigations continued under a voluntary agreement with the New Jersey Department of Environmental Protection. PPPL monitored for the presence of nonradiological contaminants, mainly volatile organic compounds (components of degreasing solvents) and petroleum hydrocarbons (past leaks of releases of diesel fuel from underground storage tanks). Also, PPPL's radiological monitoring program characterized the ambient, background levels of tritium in the environment and from the TFTR stack; the data are presented in this

  10. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Standard hourly fee rate for laboratory testing, analysis, and other services. 91.37 Section 91.37 Agriculture Regulations of the Department of Agriculture... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and...

  11. Announcement: Guidance for U.S. Laboratory Testing for Zika Virus Infection: Implications for Health Care Providers.

    PubMed

    2016-11-25

    CDC has released updated guidance online for U.S. laboratory testing for Zika virus infection. The guidance is available at https://www.cdc.gov/zika/laboratories/lab-guidance.html. Frequently asked questions are addressed at https://www.cdc.gov/zika/laboratories/lab-guidance-faq.html. This guidance updates recommendations for testing of specimens by U.S. laboratories for possible Zika virus infection. Major updates to the guidance with clinical implications for health care providers include the following.

  12. Tried and True: Tested Ideas for Teaching and Learning from the Regional Educational Laboratories.

    ERIC Educational Resources Information Center

    Levinson, Luna; Stonehill, Robert

    This collection of 16 tested ideas for improving teaching and learning evolved from the work of the 1995 Proven Laboratory Practices Task Force charged with identifying and collecting the best and most useful work from the Regional Educational Laboratories. The Regional Educational Laboratory program is the largest research and development…

  13. Launching a Laboratory Testing Process Quality Improvement Toolkit: From the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP).

    PubMed

    Fernald, Douglas; Hamer, Mika; James, Kathy; Tutt, Brandon; West, David

    2015-01-01

    Family medicine and internal medicine physicians order diagnostic laboratory tests for nearly one-third of patient encounters in an average week, yet among medical errors in primary care, an estimated 15% to 54% are attributed to laboratory testing processes. From a practice improvement perspective, we (1) describe the need for laboratory testing process quality improvements from the perspective of primary care practices, and (2) describe the approaches and resources needed to implement laboratory testing process quality improvements in practice. We applied practice observations, process mapping, and interviews with primary care practices in the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP)-affiliated practice-based research networks that field-tested in 2013 a laboratory testing process improvement toolkit. From the data collected in each of the 22 participating practices, common testing quality issues included, but were not limited to, 3 main testing process steps: laboratory test preparation, test tracking, and patient notification. Three overarching qualitative themes emerged: practices readily acknowledge multiple laboratory testing process problems; practices know that they need help addressing the issues; and practices face challenges with finding patient-centered solutions compatible with practice priorities and available resources. While practices were able to get started with guidance and a toolkit to improve laboratory testing processes, most did not seem able to achieve their quality improvement aims unassisted. Providing specific guidance tools with practice facilitation or other rapid-cycle quality improvement support may be an effective approach to improve common laboratory testing issues in primary care. © Copyright 2015 by the American Board of Family Medicine.

  14. The ACVD task force on canine atopic dermatitis (XVI): laboratory evaluation of dogs with atopic dermatitis with serum-based "allergy" tests.

    PubMed

    DeBoer, D J; Hillier, A

    2001-09-20

    Serum-based in vitro "allergy tests" are commercially available to veterinarians, and are widely used in diagnostic evaluation of a canine atopic patient. Following initial clinical diagnosis, panels of allergen-specific IgE measurements may be performed in an attempt to identify to which allergens the atopic dog is hypersensitive. Methodology for these tests varies by laboratory; few critical studies have evaluated performance of these tests, and current inter-laboratory standardization and quality control measures are inadequate. Other areas where information is critically limited include the usefulness of these tests in diagnosis of food allergy, the effect of extrinsic factors such as season of the year on results, and the influence of corticosteroid treatment on test results. Allergen-specific IgE serological tests are never completely sensitive, nor completely specific. There is only partial correlation between the serum tests and intradermal testing; however, the significance of discrepant results is unknown and unstudied. Variation in test methodologies along with the absence of universal standardization and reporting procedures have created confusion, varying study results, and an inability to compare between studies performed by different investigators.

  15. Laboratory and field tests of the Sutron RLR-0003-1 water level sensor

    USGS Publications Warehouse

    Fulford, Janice M.; Bryars, R. Scott

    2015-01-01

    Three Sutron RLR-0003-1 water level sensors were tested in laboratory conditions to evaluate the accuracy of the sensor over the manufacturer’s specified operating temperature and distance-to-water ranges. The sensor was also tested for compliance to SDI-12 communication protocol and in field conditions at a U.S. Geological Survey (USGS) streamgaging site. Laboratory results were compared to the manufacturer’s accuracy specification for water level and to the USGS Office of Surface Water (OSW) policy requirement that water level sensors have a measurement uncertainty of no more than 0.01 foot or 0.20 percent of the indicated reading. Except for one sensor, the differences for the temperature testing were within 0.05 foot and the average measurements for the sensors were within the manufacturer’s accuracy specification. Two of the three sensors were within the manufacturer’s specified accuracy and met the USGS accuracy requirements for the laboratory distance to water testing. Three units passed a basic SDI-12 communication compliance test. Water level measurements made by the Sutron RLR-0003-1 during field testing agreed well with those made by the bubbler system and a Design Analysis Associates (DAA) H3613 radar, and they met the USGS accuracy requirements when compared to the wire-weight gage readings.

  16. Diagnostic performances of clinical laboratory tests using Triton X-100 to reduce the biohazard associated with routine testing of Ebola virus-infected patients.

    PubMed

    Tempestilli, Massimo; Pucci, Luigia; Notari, Stefania; Di Caro, Antonino; Castilletti, Concetta; Rivelli, Maria Rosaria; Agrati, Chiara; Pucillo, Leopoldo Paolo

    2015-11-01

    Ebola virus, an enveloped virus, is the cause of the largest and most complex Ebola virus disease (EVD) outbreak in West Africa. Blood or body fluids of an infected person may represent a biohazard to laboratory workers. Laboratory tests of virus containing specimens should be conducted in referral centres at biosafety level 4, but based on the severity of clinical symptoms, basic laboratories might be required to execute urgent tests for patients suspected of EVD. The aim of this work was to compare the analytical performances of laboratory tests when Triton X-100, a chemical agent able to inactivate other enveloped viruses, was added to specimens. Results of clinical chemistry, coagulation and haematology parameters on samples before and after the addition of 0.1% (final concentration) of Triton X-100 and 1 h of incubation at room temperature were compared. Overall, results showed very good agreement by all statistical analyses. Triton X-100 at 0.1% did not significantly affect the results for the majority of the analytes tested. Triton X-100 at 0.1% can be used to reduce the biohazard in performing laboratory tests on samples from patients with EVD without affecting clinical decisions.

  17. Description and Laboratory Tests of a Roots Type Aircraft Engine Supercharger

    NASA Technical Reports Server (NTRS)

    Ware, Marsden

    1926-01-01

    This report describes a roots type aircraft engine supercharger and presents the results of some tests made with it at the Langley Field Laboratories of the National Advisory Committee for Aeronautics. The supercharger used in these tests was constructed largely of aluminum, weighed 88 pounds and was arranged to be operated from the rear of a standard aircraft engine at a speed of 1 1/2 engine crankshaft speed. The rotors of the supercharger were cycloidal in form and were 11 inches long and 9 1/2 inches in diameter. The displacement of the supercharger was 0.51 cubic feet of air per revolution of the rotors. The supercharger was tested in the laboratory, independently and in combination with a Liberty-12 aircraft engine, under simulated altitude pressure conditions in order to obtain information on its operation and performance. From these tests it seems evident that the Roots blower compares favorably with other compressor types used as aircraft engine superchargers and that it has several features that make it particularly attractive for such use.

  18. Digital Audio Radio Broadcast Systems Laboratory Testing Nearly Complete

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Radio history continues to be made at the NASA Lewis Research Center with the completion of phase one of the digital audio radio (DAR) testing conducted by the Consumer Electronics Group of the Electronic Industries Association. This satellite, satellite/terrestrial, and terrestrial digital technology will open up new audio broadcasting opportunities both domestically and worldwide. It will significantly improve the current quality of amplitude-modulated/frequency-modulated (AM/FM) radio with a new digitally modulated radio signal and will introduce true compact-disc-quality (CD-quality) sound for the first time. Lewis is hosting the laboratory testing of seven proposed digital audio radio systems and modes. Two of the proposed systems operate in two modes each, making a total of nine systems being tested. The nine systems are divided into the following types of transmission: in-band on-channel (IBOC), in-band adjacent-channel (IBAC), and new bands. The laboratory testing was conducted by the Consumer Electronics Group of the Electronic Industries Association. Subjective assessments of the audio recordings for each of the nine systems was conducted by the Communications Research Center in Ottawa, Canada, under contract to the Electronic Industries Association. The Communications Research Center has the only CCIR-qualified (Consultative Committee for International Radio) audio testing facility in North America. The main goals of the U.S. testing process are to (1) provide technical data to the Federal Communication Commission (FCC) so that it can establish a standard for digital audio receivers and transmitters and (2) provide the receiver and transmitter industries with the proper standards upon which to build their equipment. In addition, the data will be forwarded to the International Telecommunications Union to help in the establishment of international standards for digital audio receivers and transmitters, thus allowing U.S. manufacturers to compete in the

  19. How Do Experienced Physicians Access and Evaluate Laboratory Test Results for the Chronic Patient? A Qualitative Analysis.

    PubMed

    Torsvik, Torbjørn; Lillebo, Børge; Hertzum, Morten

    2018-04-01

     Electronic health records may present laboratory test results in a variety of ways. Little is known about how the usefulness of different visualizations of laboratory test results is influenced by the complex and varied process of clinical decision making.  The purpose of this study was to investigate how clinicians access and utilize laboratory test results when caring for patients with chronic illness.  We interviewed 10 attending physicians about how they access and assess laboratory tests when following up patients with chronic illness. The interviews were audio-recorded, transcribed verbatim, and analyzed qualitatively.  Informants preferred different visualizations of laboratory test results, depending on what aspects of the data they were interested in. As chronic patients may have laboratory test results that are permanently outside standardized reference ranges, informants would often look for significant change, rather than exact values. What constituted significant change depended on contextual information (e.g., the results of other investigations, intercurrent diseases, and medical interventions) spread across multiple locations in the electronic health record. For chronic patients, the temporal relations between data could often be of special interest. Informants struggled with finding and synthesizing fragmented information into meaningful overviews.  The presentation of laboratory test results should account for the large variety of associated contextual information needed for clinical comprehension. Future research is needed to improve the integration of the different parts of the electronic health record. Schattauer GmbH Stuttgart.

  20. The total laboratory solution: a new laboratory E-business model based on a vertical laboratory meta-network.

    PubMed

    Friedman, B A

    2001-08-01

    Major forces are now reshaping all businesses on a global basis, including the healthcare and clinical laboratory industries. One of the major forces at work is information technology (IT), which now provides the opportunity to create a new economic and business model for the clinical laboratory industry based on the creation of an integrated vertical meta-network, referred to here as the "total laboratory solution" (TLS). Participants at the most basic level of such a network would include a hospital-based laboratory, a reference laboratory, a laboratory information system/application service provider/laboratory portal vendor, an in vitro diagnostic manufacturer, and a pharmaceutical/biotechnology manufacturer. It is suggested that each of these participants would add value to the network primarily in its area of core competency. Subvariants of such a network have evolved over recent years, but a TLS comprising all or most of these participants does not exist at this time. Although the TLS, enabled by IT and closely akin to the various e-businesses that are now taking shape, offers many advantages from a theoretical perspective over the current laboratory business model, its success will depend largely on (a) market forces, (b) how the collaborative networks are organized and managed, and (c) whether the network can offer healthcare organizations higher quality testing services at lower cost. If the concept is successful, new demands will be placed on hospital-based laboratory professionals to shift the range of professional services that they offer toward clinical consulting, integration of laboratory information from multiple sources, and laboratory information management. These information management and integration tasks can only increase in complexity in the future as new genomic and proteomics testing modalities are developed and come on-line in clinical laboratories.

  1. Thermocouple Calibration and Accuracy in a Materials Testing Laboratory

    NASA Technical Reports Server (NTRS)

    Lerch, B. A.; Nathal, M. V.; Keller, D. J.

    2002-01-01

    A consolidation of information has been provided that can be used to define procedures for enhancing and maintaining accuracy in temperature measurements in materials testing laboratories. These studies were restricted to type R and K thermocouples (TCs) tested in air. Thermocouple accuracies, as influenced by calibration methods, thermocouple stability, and manufacturer's tolerances were all quantified in terms of statistical confidence intervals. By calibrating specific TCs the benefits in accuracy can be as great as 6 C or 5X better compared to relying on manufacturer's tolerances. The results emphasize strict reliance on the defined testing protocol and on the need to establish recalibration frequencies in order to maintain these levels of accuracy.

  2. Distributed Acoustic Sensing (DAS) for Periodic Hydraulic Tests: Laboratory Data

    DOE Data Explorer

    Coleman, Thomas

    2015-02-27

    These data were collected in the laboratory located at California State University Long Beach. They consist of DAS data collected from a fiber optic cable placed in a tank of water, subjected to oscillating head. These tests are described in the article linked below.

  3. The FAA's postmortem forensic toxicology self-evaluated proficiency test program: the second seven years.

    PubMed

    Chaturvedi, Arvind K; Craft, Kristi J; Cardona, Patrick S; Rogers, Paul B; Canfield, Dennis V

    2009-05-01

    During toxicological evaluations of samples from fatally injured pilots involved in civil aviation accidents, a high degree of quality control/quality assurance (QC/QA) is maintained. Under this philosophy, the Federal Aviation Administration (FAA) started a forensic toxicology proficiency-testing (PT) program in July 1991. In continuation of the first seven years of the PT findings reported earlier, PT findings of the next seven years are summarized herein. Twenty-eight survey samples (12 urine, 9 blood, and 7 tissue homogenate) with/without alcohols/volatiles, drugs, and/or putrefactive amine(s) were submitted to an average of 31 laboratories, of which an average of 25 participants returned their results. Analytes in survey samples were correctly identified and quantitated by a large number of participants, but some false positives of concern were reported. It is anticipated that the FAA's PT program will continue to serve the forensic toxicology community through this important part of the QC/QA for laboratory accreditations.

  4. Artificial Neural Network Approach in Laboratory Test Reporting:  Learning Algorithms.

    PubMed

    Demirci, Ferhat; Akan, Pinar; Kume, Tuncay; Sisman, Ali Riza; Erbayraktar, Zubeyde; Sevinc, Suleyman

    2016-08-01

    In the field of laboratory medicine, minimizing errors and establishing standardization is only possible by predefined processes. The aim of this study was to build an experimental decision algorithm model open to improvement that would efficiently and rapidly evaluate the results of biochemical tests with critical values by evaluating multiple factors concurrently. The experimental model was built by Weka software (Weka, Waikato, New Zealand) based on the artificial neural network method. Data were received from Dokuz Eylül University Central Laboratory. "Training sets" were developed for our experimental model to teach the evaluation criteria. After training the system, "test sets" developed for different conditions were used to statistically assess the validity of the model. After developing the decision algorithm with three iterations of training, no result was verified that was refused by the laboratory specialist. The sensitivity of the model was 91% and specificity was 100%. The estimated κ score was 0.950. This is the first study based on an artificial neural network to build an experimental assessment and decision algorithm model. By integrating our trained algorithm model into a laboratory information system, it may be possible to reduce employees' workload without compromising patient safety. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. The Computerized Laboratory Notebook concept for genetic toxicology experimentation and testing.

    PubMed

    Strauss, G H; Stanford, W L; Berkowitz, S J

    1989-03-01

    We describe a microcomputer system utilizing the Computerized Laboratory Notebook (CLN) concept developed in our laboratory for the purpose of automating the Battery of Leukocyte Tests (BLT). The BLT was designed to evaluate blood specimens for toxic, immunotoxic, and genotoxic effects after in vivo exposure to putative mutagens. A system was developed with the advantages of low cost, limited spatial requirements, ease of use for personnel inexperienced with computers, and applicability to specific testing yet flexibility for experimentation. This system eliminates cumbersome record keeping and repetitive analysis inherent in genetic toxicology bioassays. Statistical analysis of the vast quantity of data produced by the BLT would not be feasible without a central database. Our central database is maintained by an integrated package which we have adapted to develop the CLN. The clonal assay of lymphocyte mutagenesis (CALM) section of the CLN is demonstrated. PC-Slaves expand the microcomputer to multiple workstations so that our computerized notebook can be used next to a hood while other work is done in an office and instrument room simultaneously. Communication with peripheral instruments is an indispensable part of many laboratory operations, and we present a representative program, written to acquire and analyze CALM data, for communicating with both a liquid scintillation counter and an ELISA plate reader. In conclusion we discuss how our computer system could easily be adapted to the needs of other laboratories.

  6. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  7. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  8. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  9. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  10. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  11. SUSCEPTIBILITY TEST FOR FUNGI: CLINICAL AND LABORATORIAL CORRELATIONS IN MEDICAL MYCOLOGY.

    PubMed

    Alastruey-Izquierdo, Ana; Melhem, Marcia S C; Bonfietti, Lucas X; Rodriguez-Tudela, Juan L

    2015-09-01

    During recent decades, antifungal susceptibility testing has become standardized and nowadays has the same role of the antibacterial susceptibility testing in microbiology laboratories. American and European standards have been developed, as well as equivalent commercial systems which are more appropriate for clinical laboratories. The detection of resistant strains by means of these systems has allowed the study and understanding of the molecular basis and the mechanisms of resistance of fungal species to antifungal agents. In addition, many studies on the correlation of in vitro results with the outcome of patients have been performed, reaching the conclusion that infections caused by resistant strains have worse outcome than those caused by susceptible fungal isolates. These studies have allowed the development of interpretative breakpoints for Candida spp. and Aspergillus spp., the most frequent agents of fungal infections in the world. In summary, antifungal susceptibility tests have become essential tools to guide the treatment of fungal diseases, to know the local and global disease epidemiology, and to identify resistance to antifungals.

  12. Decentralization of CD4 testing in resource-limited settings: 7 years of experience in six African countries.

    PubMed

    Marinucci, F; Medina-Moreno, S; Paterniti, A D; Wattleworth, M; Redfield, R R

    2011-05-01

    Improving access to CD4 testing in resource-limited settings can be achieved through both centralized and decentralized testing networks. Decentralized testing models are more suitable for countries where the HIV epidemic affects a large portion of rural populations. Timely access to accurate CD4 results is crucial at the primary level of the health system. For the past 7 years, the Institute of Human Virology of the University of Maryland School of Medicine has implemented a flexible and sustainable three-phase model: (1) site assessment and improvement, (2) appropriate technology selection with capacity building through practical training and laboratory mentoring, and (3) quality management system strengthening and monitoring, to support accessibility to reliable CD4 counting at the point of service. CD4 testing capacity was established in 122 of 229 (53%) laboratories supported in Nigeria, Uganda, Kenya, Zambia, Tanzania, and Rwanda. Among those in rural settings, 46% (69/151) had CD4 testing available at site level, with a functioning flow cytometer installed at 28% (8/29) and 50% (61/122) of level 1 and level 2 sites, respectively. To strengthen local capacity, a total of 1,152 laboratory technicians were trained through 188 training sessions provided both on-site and at central locations. The overall quality of CD4 total testing procedure was assessed at 76% (92/121) of the laboratories, with 25% (23/92), 34% (31/92), and 33% (30/92) of them reporting excellent, good, and satisfactory performance. Balancing country-specific factors with the location of the clinic, number of patients, and the expected workload, was crucial in adapting this flexible model for decentralizing CD4 testing. The close collaboration with local governments and private vendors was key to successfully expanding access to CD4 testing within the framework of HIV care and treatment programs and for the sustainability of medical laboratories in resource-limited settings. Copyright © 2011

  13. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  14. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  15. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  16. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  17. 49 CFR 40.91 - What validity tests must laboratories conduct on primary specimens?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.91 What... testing under § 40.89, you must conduct it in accordance with the requirements of this section. (a) You... responses characteristic of an adulterant obtained during initial or confirmatory drug tests (e.g., non...

  18. Calgary Laboratory Services

    PubMed Central

    2015-01-01

    Calgary Laboratory Services provides global hospital and community laboratory services for Calgary and surrounding areas (population 1.4 million) and global academic support for the University of Calgary Cumming School of Medicine. It developed rapidly after the Alberta Provincial Government implemented an austerity program to address rising health care costs and to address Alberta’s debt and deficit in 1994. Over roughly the next year, all hospital and community laboratory test funding within the province was put into a single budget, fee codes for fee-for-service test billing were closed, roughly 40% of the provincial laboratory budget was cut, and roughly 40% of the pathologists left the province of Alberta. In Calgary, in the face of these abrupt changes in the laboratory environment, private laboratories, publicly funded hospital laboratories and the medical school department precipitously and reluctantly merged in 1996. The origin of Calgary Laboratory Services was likened to an “unhappy shotgun marriage” by all parties. Although such a structure could save money by eliminating duplicated services and excess capacity and could provide excellent city-wide clinical service by increasing standardization, it was less clear whether it could provide strong academic support for a medical school. Over the past decade, iterations of the Calgary Laboratory Services model have been implemented or are being considered in other Canadian jurisdictions. This case study analyzes the evolution of Calgary Laboratory Services, provides a metric-based review of academic performance over time, and demonstrates that this model, essentially arising as an unplanned experiment, has merit within a Canadian health care context. PMID:28725754

  19. Use of the laboratory tests of soil modulus in modelling pile behaviour

    NASA Astrophysics Data System (ADS)

    Dyka, Ireneusz

    2012-10-01

    This article deals with the question of theoretical description of behaviour of a single pile rested in a layered soil medium. Particular attention is paid to soil modulus which is used in calculation method for pile load-settlement curve. A brief analysis of the results obtained by laboratory tests to assess soil modulus and its nonlinear variability has been presented. The results of tests have been used in triaxial apparatus and resonant column/torsional shear device. There have also been presented the results of load-settlement calculation for a single pile under axial load with implementation of different models of soil modulus degradation. On this basis, possibilities of using particular kinds of laboratory tests in calculation procedure of foundation settlement have been presented as well as further developments of them.

  20. EVALUATION OF MIXING ENERGY IN LABORATORY FLASKS USED FOR DISPERSANT EFFECTIVENESS TESTING

    EPA Science Inventory

    The evaluation of dispersant effectiveness used for oil spills is commonly done using tests conducted in laboratory flasks. The success of a test relies on replication of the conditions at sea. We used a hot wire anemometer to characterize the turbulence characteristics in the s...

  1. Portuguese Family Physicians’ Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study

    PubMed Central

    Sá, Luísa; Costa-Santos, Cristina; Teixeira, Andreia; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto; Santos, Paulo; Martins, Carlos

    2015-01-01

    Background Physicians’ ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests. Methods A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician’s level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician’s cost estimate was compared with the true cost and the absolute error was calculated. Results One-quarter (24%; 95% confidence interval: 23%–25%) of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53–56) overestimating and 21% (95% IC: 20–22) underestimating the true actual cost. The majority (76%) of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82%) said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain. Conclusions Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care. PMID:26356625

  2. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis.

    PubMed

    Mohammed, Emad A; Naugler, Christopher

    2017-01-01

    Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. This tool will allow anyone with historic test volume data to model future demand.

  3. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis

    PubMed Central

    Mohammed, Emad A.; Naugler, Christopher

    2017-01-01

    Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand. PMID:28400996

  4. Soils Sampling and Testing Training Guide for Field and Laboratory Technicians on Roadway Construction

    DOT National Transportation Integrated Search

    1999-12-01

    This manual has been developed as a training guide for field and laboratory technicians responsible for sampling and testing of soils used in roadway construction. Soils training and certification will increase the knowledge of laboratory, production...

  5. Underground Test Area Fiscal Year 2013 Annual Quality Assurance Report Nevada National Security Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krenzien, Susan; Marutzky, Sam

    This report is required by the Underground Test Area (UGTA) Quality Assurance Plan (QAP) and identifies the UGTA quality assurance (QA) activities for fiscal year (FY) 2013. All UGTA organizations—U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO); Desert Research Institute (DRI); Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); Navarro-Intera, LLC (N-I); National Security Technologies, LLC (NSTec); and the U.S. Geological Survey (USGS)—conducted QA activities in FY 2013. The activities included conducting assessments, identifying findings and completing corrective actions, evaluating laboratory performance, and publishing documents. In addition, integrated UGTA required reading and correctivemore » action tracking was instituted.« less

  6. Current issues of personnel and laboratory practices in genetic testing

    PubMed Central

    Mark, Hon Fong Louie; Kelly, Thaddeus; Watson, Michael S; Hoeltge, Gerald; Miller, Wayne A; Beauregard, Laurent

    1995-01-01

    As genetic testing is an area with implications extending far beyond that of the primary patient, it is appropriately an area that is under increased scrutiny. To ensure that high quality is maintained in the delivery of genetic services, several agencies have developed standards and guidelines. The present article summarises important recommendations made by the American College of Medical Genetics (ACMG), the College of American Pathologists (CAP), the US Health Care Financing Administration (HCFA), and the US Food and Drug Administration (FDA) as they relate to genetic testing. Some of the standards are based on voluntary compliance, whereas others have the force of regulation. They all address issues of personnel credentials, laboratory operations, and the most critical quality assurance and control measures for diagnostic laboratories from the perspective of various agencies. In most instances, the standards promulgated by these agencies are offered as minimum criteria. The exact impact of these regulations on the practice of medical genetics has yet to be established. Images PMID:8558555

  7. Laboratory and Field Evaluation of a New Rapid Test for Detecting Wuchereria bancrofti Antigen in Human Blood

    PubMed Central

    Weil, Gary J.; Curtis, Kurt C.; Fakoli, Lawrence; Fischer, Kerstin; Gankpala, Lincoln; Lammie, Patrick J.; Majewski, Andrew C.; Pelletreau, Sonia; Won, Kimberly Y.; Bolay, Fatorma K.; Fischer, Peter U.

    2013-01-01

    Global Program to Eliminate Lymphatic Filariasis (GPELF) guidelines call for using filarial antigen testing to identify endemic areas that require mass drug administration (MDA) and for post-MDA surveillance. We compared a new filarial antigen test (the Alere Filariasis Test Strip) with the reference BinaxNOW Filariasis card test that has been used by the GPELF for more than 10 years. Laboratory testing of 227 archived serum or plasma samples showed that the two tests had similar high rates of sensitivity and specificity and > 99% agreement. However, the test strip detected 26.5% more people with filarial antigenemia (124/503 versus 98/503) and had better test result stability than the card test in a field study conducted in a filariasis-endemic area in Liberia. Based on its increased sensitivity and other practical advantages, we believe that the test strip represents a major step forward that will be welcomed by the GPELF and the filariasis research community. PMID:23690552

  8. Economic evaluation of laboratory testing strategies for hospital-associated Clostridium difficile infection.

    PubMed

    Schroeder, Lee F; Robilotti, Elizabeth; Peterson, Lance R; Banaei, Niaz; Dowdy, David W

    2014-02-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and <2 transmissions, if lateral-flow GDH diagnostic sensitivity was >93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI.

  9. Economic Evaluation of Laboratory Testing Strategies for Hospital-Associated Clostridium difficile Infection

    PubMed Central

    Robilotti, Elizabeth; Peterson, Lance R.; Banaei, Niaz; Dowdy, David W.

    2014-01-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and <2 transmissions, if lateral-flow GDH diagnostic sensitivity was >93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI. PMID:24478478

  10. Laboratory tests on the effectiveness of oral vaccination of young children against typhoid and paratyphoid A and B

    PubMed Central

    Vlădoianu, I. R.; Dimache, G.; Antohi, S.; Vlădoianu, Constanța; Zarma, Ortansa

    1965-01-01

    In Romania, pre-school children are excluded from subcutaneous inoculation with typhoid and paratyphoid A and B vaccine. The authors have therefore investigated the possibility of giving them an oral vaccine. Laboratory tests were carried out on 30 children from 3 to 7 years of age. Samples of blood serum were collected before and after vaccination and subsequently tested for (1) seroprotection in chick embryos, (2) seroprotection in white mice, (3) titration of the agglutinating antibodies, and (4) electrophoretic pattern. The results obtained showed that the oral administration of the vaccine can, under the conditions used in the test, afford a considerable degree of protection to young children. PMID:14290078

  11. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds †

    PubMed Central

    Frank, Jared A.; Brill, Anthony; Kapila, Vikram

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability. PMID:27556464

  12. Laboratory based instruction in Pakistan: Comparative evaluation of three laboratory instruction methods in biological science at higher secondary school level

    NASA Astrophysics Data System (ADS)

    Cheema, Tabinda Shahid

    This study of laboratory based instruction at higher secondary school level was an attempt to gain some insight into the effectiveness of three laboratory instruction methods: cooperative group instruction method, individualised instruction method and lecture demonstration method on biology achievement and retention. A Randomised subjects, Pre-test Post-test Comparative Methods Design was applied. Three groups of students from a year 11 class in Pakistan conducted experiments using the different laboratory instruction methods. Pre-tests, achievement tests after the experiments and retention tests one month later were administered. Results showed no significant difference between the groups on total achievement and retention, nor was there any significant difference on knowledge and comprehension test scores or skills performance. Future research investigating a similar problem is suggested.

  13. An inter-laboratory comparison study of the ANSI/BIFMA standard test method M7.1 for furniture

    EPA Science Inventory

    Five laboratories using five different test chambers participated in the study to quantify within- and between-laboratory variability in the measurement of emissions of volatile organic compounds (VOCs) from new commercial furniture test items following ANSI/BIFMA M7.1. Test item...

  14. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    PubMed

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  15. Laboratory testing and economic analysis of high RAP warm mixed asphalt.

    DOT National Transportation Integrated Search

    2009-03-24

    This report contains laboratory testing, economic analysis, literature review, and information obtained from multiple producers throughout the state of Mississippi regarding the use of high RAP (50 % to 100%) mixtures containing warm mix additives. T...

  16. 49 CFR Appendix B to Part 219 - Designation of Laboratory for Post-Accident Toxicological Testing

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Designation of Laboratory for Post-Accident.... 219, App. B Appendix B to Part 219—Designation of Laboratory for Post-Accident Toxicological Testing The following laboratory is currently designated to conduct post-accident toxicological analysis under...

  17. Idaho National Engineering Laboratory, Test Area North, Hangar 629 -- Photographs, written historical and descriptive data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-12-31

    The report describes the history of the Idaho National Engineering Laboratory`s Hangar 629. The hangar was built to test the possibility of linking jet engine technology with nuclear power. The history of the project is described along with the development and eventual abandonment of the Flight Engine Test hangar. The report contains historical photographs and architectural drawings.

  18. Implementing the Mars Science Laboratory Terminal Descent Sensor Field Test Campaign

    NASA Technical Reports Server (NTRS)

    Montgomery, James F.; Bodie, James H.; Brown, Joseph D.; Chen, Allen; Chen, Curtis W.; Essmiller, John C.; Fisher, Charles D.; Goldberg, Hannah R.; Lee, Steven W.; Shaffer, Scott J.

    2012-01-01

    The Mars Science Laboratory (MSL) will deliver a 900 kg rover to the surface of Mars in August 2012. MSL will utilize a new pulse-Doppler landing radar, the Terminal Descent Sensor (TDS). The TDS employs six narrow-beam antennas to provide unprecedented slant range and velocity performance at Mars to enable soft touchdown of the MSL rover using a unique sky crane Entry, De-scent, and Landing (EDL) technique. Prior to use on MSL, the TDS was put through a rigorous verification and validation (V&V) process. A key element of this V&V was operating the TDS over a series of field tests, using flight-like profiles expected during the descent and landing of MSL over Mars-like terrain on Earth. Limits of TDS performance were characterized with additional testing meant to stress operational modes outside of the expected EDL flight profiles. The flight envelope over which the TDS must operate on Mars encompasses such a large range of altitudes and velocities that a variety of venues were neces-sary to cover the test space. These venues included an F/A-18 high performance aircraft, a Eurocopter AS350 AStar helicopter and 100-meter tall Echo Towers at the China Lake Naval Air Warfare Center. Testing was carried out over a five year period from July 2006 to June 2011. TDS performance was shown, in gen-eral, to be excellent over all venues. This paper describes the planning, design, and implementation of the field test campaign plus results and lessons learned.

  19. Creating Best Practices for the Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories.

    PubMed

    Wangsness, Kathryn; Salfinger, Yvonne; Randolph, Robyn; Shea, Shari; Larson, Kirsten

    2017-07-01

    Laboratory accreditation provides a level of standardization in laboratories and confidence in generated food and feed testing results. For some laboratories, ISO/IEC 17025:2005 accreditation may not be fiscally viable, or a requested test method may be out of the scope of the laboratory's accreditation. To assist laboratories for whom accreditation is not feasible, the Association of Public Health Laboratories Data Acceptance Work Group developed a white paper entitled "Best Practices for Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories." The basic elements of a quality management system, along with other best practices that state and local food and feed testing laboratories should follow, are included in the white paper. It also covers program-specific requirements that may need to be addressed. Communication with programs and end data users is regarded as essential for establishing the reliability and accuracy of laboratory data. Following these suggested best practices can facilitate the acceptance of laboratory data, which can result in swift regulatory action and the quick removal of contaminated product from the food supply, improving public health nationally.

  20. Predictive value and efficiency of laboratory testing.

    PubMed

    Galen, R S

    1980-11-01

    Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.