Sample records for yttrium-90 labeled resin

  1. Determination of strontium-90 from direct separation of yttrium-90 by solid phase extraction using DGA Resin for seawater monitoring.

    PubMed

    Tazoe, Hirofumi; Obata, Hajime; Yamagata, Takeyasu; Karube, Zin'ichi; Nagai, Hisao; Yamada, Masatoshi

    2016-05-15

    It is important for public safety to monitor strontium-90 in aquatic environments in the vicinity of nuclear related facilities. Strontium-90 concentrations in seawater exceeding the background level have been observed in accidents of nuclear facilities. However, the analytical procedure for measuring strontium-90 in seawater is highly demanding. Here we show a simple and high throughput analytical technique for the determination of strontium-90 in seawater samples using a direct yttrium-90 separation. The DGA Resin is used to determine the abundance of strontium-90 by detecting yttrium-90 decay (beta-emission) in secular equilibrium. The DGA Resin can selectively collect yttrium-90 and remove naturally occurring radionuclides such as (40)K, (210)Pb, (214)Bi, (238)U, and (232)Th and anthropogenic radionuclides such as (140)Ba, and (140)La. Through a sample separation procedure, a high chemical yield of yttrium-90 was achieved at 95.5±2.3%. The result of IAEA-443 certified seawater analysis (107.7±3.4 mBq kg(-1)) was in good agreement with the certified value (110±5 mBq kg(-1)). By developed method, we can finish analyzing 8 samples per day after achieving secular equilibrium, which is a reasonably fast throughput in actual seawater monitoring. By processing 3 L of seawater sample and applying a counting time of 20 h, minimum detectable activity can be as low as 1.5 mBq kg(-1), which could be applied to monitoring for the contaminated marine environment. Reproducibility was found to be 3.4% according to 10 independent analyses of natural seawater samples from the vicinity of the Fukushima Daiichi Nuclear Power Plant in September 2013. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Patient Selection and Activity Planning Guide for Selective Internal Radiotherapy With Yttrium-90 Resin Microspheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lau, Wan-Yee, E-mail: josephlau@surgery.cuhk.edu.hk; Kennedy, Andrew S.; Department of Biomedical Engineering, North Carolina State University, Raleigh, NC

    Purpose: Selective internal radiotherapy (SIRT) with yttrium-90 ({sup 90}Y) resin microspheres can improve the clinical outcomes for selected patients with inoperable liver cancer. This technique involves intra-arterial delivery of {beta}-emitting microspheres into hepatocellular carcinomas or liver metastases while sparing uninvolved structures. Its unique mode of action, including both {sup 90}Y brachytherapy and embolization of neoplastic microvasculature, necessitates activity planning methods specific to SIRT. Methods and Materials: A panel of clinicians experienced in {sup 90}Y resin microsphere SIRT was convened to integrate clinical experience with the published data to propose an activity planning pathway for radioembolization. Results: Accurate planning is essentialmore » to minimize potentially fatal sequelae such as radiation-induced liver disease while delivering tumoricidal {sup 90}Y activity. Planning methods have included empiric dosing according to degree of tumor involvement, empiric dosing adjusted for the body surface area, and partition model calculations using Medical Internal Radiation Dose principles. It has been recommended that at least two of these methods be compared when calculating the microsphere activity for each patient. Conclusions: Many factors inform {sup 90}Y resin microsphere SIRT activity planning, including the therapeutic intent, tissue and vasculature imaging, tumor and uninvolved liver characteristics, previous therapies, and localization of the microsphere infusion. The influence of each of these factors has been discussed.« less

  3. Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva, Suresh de, E-mail: suresh.desilva@unsw.edu.au; Mackie, Simon; Aslan, Peter

    BackgroundIntra-arterial brachytherapy with yttrium-90 ({sup 90}Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of {sup 90}Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with {sup 90}Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extentmore » of tissue necrosis from {sup 90}Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with {sup 90}Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the {sup 90}Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10{sup 6}) of bland microspheres.ConclusionThis study showed that radioembolization with {sup 90}Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of {sup 90}Y resin microspheres for the localized treatment of kidney tumors.« less

  4. Temporary balloon occlusion of the common hepatic artery for administration of yttrium-90 resin microspheres in a patient with patent hepatoenteric collaterals.

    PubMed

    Mahvash, Armeen; Zaer, Navid; Shaw, Colette; Chasen, Beth; Avritscher, Rony; Murthy, Ravi

    2012-02-01

    The most common serious complication of yttrium-90 ((90)Y) therapy is gastrointestinal ulceration caused by extrahepatic microsphere dispersion. The authors describe the use of a balloon catheter for temporary occlusion of the common hepatic artery to reverse hepatoenteric flow for lobar administration of resin microspheres when coil embolization of a retroportal artery was impossible. At 9 months after treatment, the patient had no gastrointestinal side effects and showed a partial response. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  5. Biodistribution of Yttrium-90-Labeled Anti-CD45 Antibody in a Nonhuman Primate Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nemecek, Eneida; Hamlin, Donald K.; Fisher, Darrell R.

    2005-01-15

    Radioimmunotherapy may improve the outcome of hematopoietic cell transplantation for hematologic malignancies by delivering targeted radiation to hematopoietic organs while relatively sparing nontarget organs. We evaluated the organ localization of yttrium-90-labeled anti-CD45 (90Y-anti-CD45) antibody in macaques, a model that had previously predicted iodine-131-labeled anti-CD-45 (131I-anti-CD45) antibody biodistribution in humans. Experimental Design: Twelve Macaca nemestrina primates received anti-CD45 antibody labeled with 1 to 2 mCi of 90Y followed by serial blood sampling and marrow and lymph node biopsies, and necropsy. The content of 90Y per gram of tissue was determined by liquid scintillation spectrometry. Time-activity curves were constructed using average isotopemore » concentrations in each tissue at measured time points to yield the fractional residence time and estimate radiation absorbed doses for each organ per unit of administered activity. The biodistribution of 90Y-anti-CD45 antibody was then compared with that previously obtained with 131I-anti-CD45 antibody in macaques. Results: The spleen received 2,120, marrow 1,060, and lymph nodes 315 cGy/mCi of 90Y injected. The liver and lungs were the nontarget organs receiving the highest radiation absorbed doses (440 and 285 cGy/mCi, respectively). Ytrrium-90-labeled anti-CD45 antibody delivered 2.5- and 3.7-fold more radiation to marrow than to liver and lungs, respectively. The ratios previously observed with 131I-antiCD45 antibody were 2.5-and 2.2-fold more radiation to marrow than to liver and lungs, respectively. Conclusions: This study shows that 90Y-anti-CD45 antibody can deliver relatively selective radiation to hematopoietic tissues, with similar ratios of radiation delivered to target versus nontarget organs, as compared with the 131I immunoconjugate in the same animal model.« less

  6. Optimized conditions for chelation of yttrium-90-DOTA immunoconjugates.

    PubMed

    Kukis, D L; DeNardo, S J; DeNardo, G L; O'Donnell, R T; Meares, C F

    1998-12-01

    Radioimmunotherapy (RIT) with 90Y-labeled immunoconjugates has shown promise in clinical trials. The macrocyclic chelating agent 1,4,7,10-tetraazacyclododecane-N,N',N",N"'-tetraacetic acid (DOTA) binds 90Y with extraordinary stability, minimizing the toxicity of 90Y-DOTA immunoconjugates arising from loss of 90Y to bone. However, reported 90Y-DOTA immunoconjugate product yields have been typically only < or =50%. Improved yields are needed for RIT with 90Y-DOTA immunoconjugates to be practical. (S) 2-[p-(bromoacetamido)benzyl]-DOTA (BAD) was conjugated to the monoclonal antibody Lym-1 via 2-iminothiolane (2IT). The immunoconjugate product, 2IT-BAD-Lym-1, was labeled in excess yttrium in various buffers over a range of concentrations and pH. Kinetic studies were performed in selected buffers to estimate radiolabeling reaction times under prospective radiopharmacy labeling conditions. The effect of temperature on reaction kinetics was examined. Optimal radiolabeling conditions were identified and used in eight radiolabeling experiments with 2IT-BAD-Lym-1 and a second immunoconjugate, DOTA-peptide-chimeric L6, with 248-492 MBq (6.7-13.3 mCi) of 90Y. Ammonium acetate buffer (0.5 M) was associated with the highest uptake of yttrium. On the basis of kinetic data, the time required to chelate 94% of 90Y (four half-times) under prospective radiopharmacy labeling conditions in 0.5 M ammonium acetate was 17-148 min at pH 6.5, but it was only 1-10 min at pH 7.5. Raising the reaction temperature from 25 degrees C to 37 degrees C markedly increased the chelation rate. Optimal radiolabeling conditions were identified as: 30-min reaction time, 0.5 M ammonium acetate buffer, pH 7-7.5 and 37 degrees C. In eight labeling experiments under optimal conditions, a mean product yield (+/- s.d.) of 91%+/-8% was achieved, comparable to iodination yields. The specific activity of final products was 74-130 MBq (2.0-3.5 mCi) of 90Y per mg of monoclonal antibody. The immunoreactivity of 90Y-labeled

  7. Safety of Radioembolization with {sup 90}Yttrium Resin Microspheres Depending on Coiling or No-Coiling of Aberrant/High-Risk Vessels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paprottka, P. M., E-mail: philipp.paprottka@med.lmu.de, E-mail: philipp.paprottka@med.uni-muenchen.de; Paprottka, K. J., E-mail: karolin.paprottka@med.lmu.de; Walter, A., E-mail: alexandra.Walter@campus.lmu.de

    2015-08-15

    PurposeTo evaluate the safety of radioembolization (RE) with {sup 90}Yttrium ({sup 90}Y) resin microspheres depending on coiling or no-coiling of aberrant/high-risk vessels.Materials and MethodsEarly and late toxicity after 566 RE procedures were analyzed retrospectively in accordance with the National Cancer Institute’s Common Terminology Criteria for Adverse Events (CTCAE v3.0). For optimal safety, aberrant vessels were either coil embolized (n = 240/566, coiling group) or a more peripheral position of the catheter tip was chosen to treat right or left liver lobes (n = 326/566, no-coiling group).ResultsClinically relevant late toxicities (≥Grade 3) were observed in 1 % of our overall cohort. The no-coiling group had significantlymore » less “any” (P = 0.0001) or “clinically relevant” (P = 0.0003) early toxicity. There was no significant difference (P > 0.05) in delayed toxicity in the coiling versus the no-coiling group. No RE-induced liver disease was noted after all 566 procedures.ConclusionRE with {sup 90}Y resin microspheres is a safe and effective treatment option. Performing RE without coil embolization of aberrant vessels prior to treatment could be an alternative for experienced centers.« less

  8. Use of Chelex-100 for selectively removing Y-90 from its parent Sr-90

    DOEpatents

    Huntley, Mark W.

    1996-01-01

    A method for selectively removing yttrium-90 from its parent strontium-90 contained in an environmental sample includes loading the sample onto a column containing a chelating ion-exchange resin capable of retaining yttrium-90; washing the column with a solution capable of removing strontium, calcium, and other contaminants from the yttrium-90 fraction retained on the column; removing excess acetate salts from the column; eluting yttrium-90 solution from the column and adjusting the pH of this solution to about 2.7; filtering the yttrium-90 solution and weighing this solution for gravimetric yield; and, counting the yttrium-90 containing solution with a radiological counter for a time sufficient to achieve the statistical accuracy desired. It is preferred that the chelating ion-exchange resin is a bidente ligand having the chemical name iminodiacetic acid mounted on a divinyl benzene substrate, converted from sodium form to ammonia form.

  9. Use of Chelex-100 for selectively removing Y-90 from its parent Sr-90

    DOEpatents

    Huntley, M.W.

    1996-02-27

    A method for selectively removing yttrium-90 from its parent strontium-90 contained in an environmental sample includes loading the sample onto a column containing a chelating ion-exchange resin capable of retaining yttrium-90; washing the column with a solution capable of removing strontium, calcium, and other contaminants from the yttrium-90 fraction retained on the column; removing excess acetate salts from the column; eluting yttrium-90 solution from the column and adjusting the pH of this solution to about 2.7; filtering the yttrium-90 solution and weighing this solution for gravimetric yield; and, counting the yttrium-90 containing solution with a radiological counter for a time sufficient to achieve the statistical accuracy desired. It is preferred that the chelating ion-exchange resin is a ligand having the chemical name iminodiacetic acid mounted on a divinyl benzene substrate, converted from sodium form to ammonia form.

  10. Yttrium-90 (Y-90) Resin Microsphere Therapy for Patients with Unresectable Hepatocellular Carcinoma: a Single-Center Experience.

    PubMed

    İnce, Semra; Karaman, Bülent; Alagoz, Engin; Karadurmuş, Nuri; Şan, Hüseyin; Erçin, Cemal Nuri; Arslan, Nuri

    2017-09-01

    Selective intraarterial radionuclide therapy (SIRT) with yttrium-90 (Y-90) resin microspheres presently has successful results in primary or metastatic inoperable liver tumors. This procedure, which is also known as radioembolisation, delivers high doses of radiation selectively to hepatic tumors while minimum healthy liver exposure. The aim of this study was to present our clinical experience of radiomicrosphere therapy for the treatment of patients with unresectable hepatocellular carcinoma (HCC). We performed 40 Y-90 microsphere therapies in 28 patients (5 females, 23 males; mean age ± SD 48 ± 8) with HCC during the period from April 2008 through December 2016. Pretreatment Tc-99m microaggregated albumin (MAA) scintigraphy was performed to all patients in order to detect eligibility for SIRT. All patients had pre- and post-biochemical tests (hemogram and serologic tests) and imaging methods (CT or MRI or PET/CT) at regular intervals to detect any possible complication and determine response rates. The mean shunting to the lungs on MAA scan was 6.5% and the mean ± SD administered dose of Y-90 was 1.55 ± 0.32 GBq in all patients. The estimated doses to the target tumors, normal liver parenchyma and lungs were 105.7 ± 55.3, 25.5 ± 8.2 and 5.8 ± 1.7 Gy, respectively. No significant complication was observed during or early after (first week) the treatment procedure and it was well tolerated by all the patients. Only one patient developed a treatment-related gastroduodenal ulcer 3 weeks after the treatment. In control imaging tests (MRI or FDG PET/CT) performed 2.5 months after the treatment, we observed complete response in 2 (7%) patients, partial response in 10 (36%) patients, stable disease in 5 (18%) patients and progressive disease in 11 (39%) patients. According to our clinical experience, we can conclude that Y-90 microsphere therapy is a safe and effective treatment option for the patients with unresectable HCC without any serious

  11. Shape-Controlled Synthesis of Isotopic Yttrium-90-Labeled Rare Earth Fluoride Nanocrystals for Multimodal Imaging.

    PubMed

    Paik, Taejong; Chacko, Ann-Marie; Mikitsh, John L; Friedberg, Joseph S; Pryma, Daniel A; Murray, Christopher B

    2015-09-22

    Isotopically labeled nanomaterials have recently attracted much attention in biomedical research, environmental health studies, and clinical medicine because radioactive probes allow the elucidation of in vitro and in vivo cellular transport mechanisms, as well as the unambiguous distribution and localization of nanomaterials in vivo. In addition, nanocrystal-based inorganic materials have a unique capability of customizing size, shape, and composition; with the potential to be designed as multimodal imaging probes. Size and shape of nanocrystals can directly influence interactions with biological systems, hence it is important to develop synthetic methods to design radiolabeled nanocrystals with precise control of size and shape. Here, we report size- and shape-controlled synthesis of rare earth fluoride nanocrystals doped with the β-emitting radioisotope yttrium-90 ((90)Y). Size and shape of nanocrystals are tailored via tight control of reaction parameters and the type of rare earth hosts (e.g., Gd or Y) employed. Radiolabeled nanocrystals are synthesized in high radiochemical yield and purity as well as excellent radiolabel stability in the face of surface modification with different polymeric ligands. We demonstrate the Cerenkov radioluminescence imaging and magnetic resonance imaging capabilities of (90)Y-doped GdF3 nanoplates, which offer unique opportunities as a promising platform for multimodal imaging and targeted therapy.

  12. Survival after yttrium-90 resin microsphere radioembolization of hepatocellular carcinoma across Barcelona clinic liver cancer stages: a European evaluation.

    PubMed

    Sangro, Bruno; Carpanese, Livio; Cianni, Roberto; Golfieri, Rita; Gasparini, Daniele; Ezziddin, Samer; Paprottka, Philipp M; Fiore, Francesco; Van Buskirk, Mark; Bilbao, Jose Ignacio; Ettorre, Giuseppe Maria; Salvatori, Rita; Giampalma, Emanuela; Geatti, Onelio; Wilhelm, Kai; Hoffmann, Ralf Thorsten; Izzo, Francesco; Iñarrairaegui, Mercedes; Maini, Carlo Ludovico; Urigo, Carlo; Cappelli, Alberta; Vit, Alessandro; Ahmadzadehfar, Hojjat; Jakobs, Tobias Franz; Lastoria, Secondo

    2011-09-02

    A multicenter analysis was conducted to evaluate the main prognostic factors driving survival after radioembolization using yttrium-90-labeled resin microspheres in patients with hepatocellular carcinoma at eight European centers. In total, 325 patients received a median activity of 1.6 GBq between September 2003 and December 2009, predominantly as whole-liver (45.2%) or right-lobe (38.5%) infusions. Typically, patients were Child-Pugh class A (82.5%), had underlying cirrhosis (78.5%), and had good Eastern Cooperative Oncology Group (ECOG) performance status (ECOG 0-1; 87.7%), but many had multinodular disease (75.9%) invading both lobes (53.1%) and/or portal vein occlusion (13.5% branch; 9.8% main). Over half had advanced Barcelona Clinic Liver Cancer (BCLC) staging (BCLC C, 56.3%) and one-quarter had intermediate staging (BCLC B, 26.8%). The median overall survival was 12.8 months (95% confidence interval, 10.9-15.7), which varied significantly by disease stage (BCLC A, 24.4 months [95% CI, 18.6-38.1 months]; BCLC B, 16.9 months [95% CI, 12.8-22.8 months]; BCLC C, 10.0 months [95% CI, 7.7-10.9 months]). Consistent with this finding , survival varied significantly by ECOG status, hepatic function (Child-Pugh class, ascites, and baseline total bilirubin), tumor burden (number of nodules, alpha-fetoprotein), and presence of extrahepatic disease. When considered within the framework of BCLC staging, variables reflecting tumor burden and liver function provided additional prognostic information. The most significant independent prognostic factors for survival upon multivariate analysis were ECOG status, tumor burden (nodules >5), international normalized ratio >1.2, and extrahepatic disease. Common adverse events were: fatigue, nausea/vomiting, and abdominal pain. Grade 3 or higher increases in bilirubin were reported in 5.8% of patients. All-cause mortality was 0.6% and 6.8% at 30 and 90 days, respectively. This analysis provides robust evidence of the survival

  13. Yttrium 90 ibritumomab tiuxetan radioimmunotherapy for relapsed or refractory low-grade non-Hodgkin's lymphoma.

    PubMed

    Gordon, Leo I; Witzig, Thomas E; Wiseman, Greg A; Flinn, Ian W; Spies, Stewart S; Silverman, Daniel H; Emmanuolides, Christos; Cripe, Larry; Saleh, Mansoor; Czuczman, Myron S; Olejnik, Teresa; White, Christine A; Grillo-López, Antonio J

    2002-02-01

    The treatment of malignant lymphoma has improved over the past 20 years, but the majority of patients are not cured. New modalities using targeted therapy based on new information in molecular biology and immunology hold promise for better outcomes with less toxicity. We review data on the use of radiolabeled monoclonal antibodies directed against the CD20 antigen on malignant B cells. We discuss the major radionuclides available, iodine 131 ( 131 I), tositumomab, and yttrium 90 ( 90 Y) ibritumomab tiuxetan (Zevalin; IDEC Pharmaceuticals, San Diego, CA) and present data on new approaches in labeling antibodies that have facilitated their use. Clinical trial data with the yttrium-labeled antibodies are discussed. The use of dosimetry as a means for predicting toxicity is discussed, and the questions of long-term toxicity (late effects) are addressed. These targeted approaches to the treatment of malignancy, and lymphoma in particular, hold great promise. Semin Oncol 29 (suppl 2):87-92. Copyright © 2002 by W.B. Saunders Company. Copyright © 2002 W.B. Saunders Company. All rights reserved.

  14. Intraprocedural yttrium-90 positron emission tomography/CT for treatment optimization of yttrium-90 radioembolization.

    PubMed

    Bourgeois, Austin C; Chang, Ted T; Bradley, Yong C; Acuff, Shelley N; Pasciak, Alexander S

    2014-02-01

    Radioembolization with yttrium-90 ((90)Y) microspheres relies on delivery of appropriate treatment activity to ensure patient safety and optimize treatment efficacy. We report a case in which (90)Y positron emission tomography (PET)/computed tomography (CT) was performed to optimize treatment planning during a same-day, three-part treatment session. This treatment consisted of (i) an initial (90)Y infusion with a dosage determined using an empiric treatment planning model, (ii) quantitative (90)Y PET/CT imaging, and (iii) a secondary infusion with treatment planning based on quantitative imaging data with the goal of delivering a specific total tumor absorbed dose. © 2014 SIR Published by SIR All rights reserved.

  15. Effects of radiolysis on yttrium-90-labeled Lym-1 antibody preparations.

    PubMed

    Salako, Q A; O'Donnell, R T; DeNardo, S J

    1998-04-01

    The physical half-life of 2.6 days and 2.2 MeV beta emissions of 90Y provide excellent properties for radioimmunotherapy applications. However, the clinically useful beta particles may be a source of radiation-induced damage of 90Y-labeled immunoconjugate radiopharmaceuticals during preparation or short-term storage. The stability of 90Y-labeled Lym-1 antibody was studied in standard radiopharmacy conditions to establish a formulation at which radiolysis is not a problem. Lym-1-21T-BAD immunoconjugate intermediate was prepared according to our standard procedure, then labeled with 90Y at 1, 2, 4 and 9.4 mCi/mg Lym-1 using 0.5 M tetramethylammonium acetate, pH 7, labeling buffer. Each mixture was challenged in diethylenetriaminepentaacetic acid to remove nonspecifically bound 90Y. The 90Y-21T-BAD-Lym-1 products were purified by centrifuged molecular sieving column chromatography. The radiochemical purity and immunoreactivity of each preparation was monitored daily by high-performance liquid chromatography (HPLC) and solid-phase radioimmunoassay, respectively, for 3 days. The preparation at 2 mCi/mg was also formulated in 4% (wt/vol) human serum albumin (HSA) overall and at 9.4 mCi/mg in five-fold water, 4 and 10% (wt/vol) HSA overall; all were monitored as above. The monomeric quality and purity profile of products at 1 and 2 mCi/mg were retained (> or = 80%) as was their immunoreactivity (> or = 75%) over 3 days. The radiochemical purity and immunoreactivity of the product at 4 mCi/mg declined to 65% and 28%, respectively, by 3 days after preparation and in just 48 hr, the product at 9.4 mCi/mg had degraded to 21% in radiochemical purity with only 3% immunoreactivity. The current HPLC data and earlier published chromatographic evidence did not support a compromised radiochemical integrity of 90Y-DOTA complexes by loss of 90Y from the DOTA chelate. Radiolysis of 90Y-labeled antibody preparations did not appear to be a problem at 90Y-21T-BAD-Lym-1 products < or = 2 m

  16. Yttrium-90 -- current status, expected availability and applications of a high beta energy emitter.

    PubMed

    Montaña, R Leyva; González, I Hernández; Ramirez, A Alberti; Garaboldi, L; Chinol, M

    2012-07-01

    Yttrium-90 ((90)Y, T(1/2) 64.14 h) is a key example of a high beta energy-emitting radionuclide which is available from the strontium-90 ((90)Sr)/(90)Y radionuclide generator system. Clinical uses of (90)Y-labeled radiopharmaceutical agents have been pursued for many years and many applications have proven to be clinical effective. These most notably include the application of 90Y-labeled antibodies for a variety of applications such as for effective treatment of non-Hodgkin's lymphoma. One of the major advantages for use of (90)Y is ready availability from the very long-lived (90)Sr parent (T(1/2) 28.78 y). Because of the importance of maintaining generator performance and minimizing parent breakthrough, this paper describes development, use and quality control of both high capacity cation adsorption-type and electrochemical generator systems. In addition, the preparation and targeting to tumors in mice of DOTA-conjugated Nimotuzamab (h-R3) antibody which recognizes the external domain of the EPFR antibody radiolabeled with (90)Y obtained from the electrochemical generator is also described. As a key example for clinical applications of (90)Y, the use of (90)Y-labeled biotin for intra-operative pre-targeting for radionuclide therapy (IART®) of breast cancer is also described.

  17. Rapid determination of strontium-90 by solid phase extraction using DGA Resin® for seawater monitoring

    NASA Astrophysics Data System (ADS)

    Tazoe, H.; Obata, H.; Yamagata, T.; Karube, Z.; Yamada, M.

    2015-12-01

    Strontium-90 concentrations in seawater exceeding the background level have been observed at the accidents of nuclear facilities, such as Chernobyl and Fukushima. However, analytical procedure for strontium-90 in seawater is still quite complicated and challenging. Here we show a simple and rapid analytical technique for the determination of strontium-90 in seawater samples without time-consuming separation of strontium from calcium. The separation with DGA Resin® is used to determine the abundance of strontium-90, which selectively collects yttrium-90, progeny of strontium-90. Naturally occurring radioactive nuclides (such as potassium, lead, bismuth, uranium, and thorium) and anthropogenic radionuclides (such as cesium, barium, lanthanum, and cerium) were separated from yttrium. Through a sample separation procedure, a high chemical yield of yttrium-90 was achieved at 93.9 % for seawater. The result of IAEA 443 certified seawater analysis was in good agreement with the certified value. At 20 hrs counting a lower detection limit of 1.5 mBq L-1 was obtained from 3 L of seawater. The proposed method can finish analyzing 8 samples per day, which is a reasonably fast throughput in actual seawater monitoring. Reproducibility was found to be 3.4 % according to 10 separate analyses of natural seawater samples from the vicinity of Fukushima Daiichi Nuclear Power Plant in September 2013.

  18. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morshedi, Maud M., E-mail: maud.morshedi@my.rfums.org; Bauman, Michael, E-mail: mbauman@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu

    2015-04-15

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose,more » radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.« less

  19. Availability of yttrium-90 from strontium-90: a nuclear medicine perspective.

    PubMed

    Chakravarty, Rubel; Dash, Ashutosh; Pillai, M R A

    2012-12-01

    Yttrium-90 (T(½) 64.1 hours, E(βmax)=2.28 MeV) is a pure β⁻ particle emitting radionuclide with well-established applications in targeted therapy. There are several advantages of ⁹⁰Y as a therapeutic radionuclide. It has a suitable physical half-life (∼64 hours) and decays to a stable daughter product ⁹⁰Zr by emission of high-energy β⁻ particles. Yttrium has a relatively simple chemistry and its suitability for forming complexes with a variety of chelating agents is well established. The ⁹⁰Sr/⁹⁰Y generator is an ideal source for the long-term continuous availability of no-carrier-added ⁹⁰Y suitable for the preparation of radiopharmaceuticals for radionuclide therapy. The parent radionuclide ⁹⁰Sr, which is a long-lived fission product, is available in large quantities from spent fuel. Several useful technologies have been developed for the preparation of ⁹⁰Sr/⁹⁰Y generators. There are several well-established radiopharmaceuticals based on monoclonal antibodies, peptides, and particulates labeled with ⁹⁰Y, that are in regular use for the treatment of some forms of primary cancers and arthritis. At present, there are no generators for the elution of ⁹⁰Y that can be set up in a hospital radiopharmacy. The radionuclide is procured from manufacturers and the radiopharmaceuticals are formulated on site. This article reviews the development of ⁹⁰Sr/⁹⁰Y generator and the development of ⁹⁰Y radiopharmaceuticals.

  20. Root Cause Analysis of Gastroduodenal Ulceration After Yttrium-90 Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lam, Marnix G. E. H.; Banerjee, Subhas; Louie, John D.

    IntroductionA root cause analysis was performed on the occurrence of gastroduodenal ulceration after hepatic radioembolization (RE). We aimed to identify the risk factors in the treated population and to determine the specific mechanism of nontarget RE in individual cases. Methods: The records of 247 consecutive patients treated with yttrium-90 RE for primary (n = 90) or metastatic (n = 157) liver cancer using either resin (n = 181) or glass (n = 66) microspheres were reviewed. All patients who developed a biopsy-proven microsphere-induced gastroduodenal ulcer were identified. Univariate and multivariate analyses were performed on baseline parameters and procedural data tomore » determine possible risk factors in the total population. Individual cases were analyzed to ascertain the specific cause, including identification of the culprit vessel(s) leading to extrahepatic deposition of the microspheres. Results: Eight patients (3.2 %) developed a gastroduodenal ulcer. Stasis during injection was the strongest independent risk factor (p = 0.004), followed by distal origin of the gastroduodenal artery (p = 0.004), young age (p = 0.040), and proximal injection of the microspheres (p = 0.043). Prolonged administrations, pain during administration, whole liver treatment, and use of resin microspheres also showed interrelated trends in multivariate analysis. Retrospective review of intraprocedural and postprocedural imaging showed a probable or possible culprit vessel, each a tiny complex collateral vessel, in seven patients. Conclusion: Proximal administrations and those resulting in stasis of flow presented increased risk for gastroduodenal ulceration. Patients who had undergone bevacizumab therapy were at high risk for developing stasis.« less

  1. Efficacy and safety of selective internal radiotherapy with yttrium-90 resin microspheres compared with sorafenib in locally advanced and inoperable hepatocellular carcinoma (SARAH): an open-label randomised controlled phase 3 trial.

    PubMed

    Vilgrain, Valérie; Pereira, Helena; Assenat, Eric; Guiu, Boris; Ilonca, Alina Diana; Pageaux, Georges-Philippe; Sibert, Annie; Bouattour, Mohamed; Lebtahi, Rachida; Allaham, Wassim; Barraud, Hélène; Laurent, Valérie; Mathias, Elodie; Bronowicki, Jean-Pierre; Tasu, Jean-Pierre; Perdrisot, Rémy; Silvain, Christine; Gerolami, René; Mundler, Olivier; Seitz, Jean-Francois; Vidal, Vincent; Aubé, Christophe; Oberti, Frédéric; Couturier, Olivier; Brenot-Rossi, Isabelle; Raoul, Jean-Luc; Sarran, Anthony; Costentin, Charlotte; Itti, Emmanuel; Luciani, Alain; Adam, René; Lewin, Maïté; Samuel, Didier; Ronot, Maxime; Dinut, Aurelia; Castera, Laurent; Chatellier, Gilles

    2017-12-01

    Sorafenib is the recommended treatment for patients with advanced hepatocellular carcinoma. We aimed to compare the efficacy and safety of sorafenib to that of selective internal radiotherapy (SIRT) with yttrium-90 ( 90 Y) resin microspheres in patients with hepatocellular carcinoma. SARAH was a multicentre, open-label, randomised, controlled, investigator-initiated, phase 3 trial done at 25 centres specialising in liver diseases in France. Patients were eligible if they were aged at least 18 years with a life expectancy greater than 3 months, had an Eastern Cooperative Oncology Group (ECOG) performance status of 0 or 1, Child-Pugh liver function class A or B score of 7 or lower, and locally advanced hepatocellular carcinoma (Barcelona Clinic Liver Cancer [BCLC] stage C), or new hepatocellular carcinoma not eligible for surgical resection, liver transplantation, or thermal ablation after a previously cured hepatocellular carcinoma (cured by surgery or thermoablative therapy), or hepatocellular carcinoma with two unsuccessful rounds of transarterial chemoembolisation. Patients were randomly assigned (1:1) by a permutated block method with block sizes two and four to receive continuous oral sorafenib (400 mg twice daily) or SIRT with 90 Y-loaded resin microspheres 2-5 weeks after randomisation. Patients were stratified according to randomising centre, ECOG performance status, previous transarterial chemoembolisation, and presence of macroscopic vascular invasion. The primary endpoint was overall survival. Analyses were done on the intention-to-treat population; safety was assessed in all patients who received at least one dose of sorafenib or underwent at least one of the SIRT work-up exams. This study has been completed and the final results are reported here. The trial is registered with ClinicalTrials.gov, number NCT01482442. Between Dec 5, 2011, and March 12, 2015, 467 patients were randomly assigned; after eight patients withdrew consent, 237 were assigned to

  2. Abscopal Effects and Yttrium-90 Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghodadra, Anish; Bhatt, Sumantha; Camacho, Juan C.

    2016-07-15

    We present the case of an 80-year-old male with squamous cell carcinoma with bilobar hepatic metastases who underwent targeted Yttrium-90 radioembolization of the right hepatic lobe lesion. Subsequently, there was complete regression of the nontargeted, left hepatic lobe lesion. This may represent the first ever reported abscopal effect in radioembolization. The abscopal effect refers to the phenomenon of tumor response in nontargeted sites after targeted radiotherapy. In this article, we briefly review the immune-mediated mechanisms responsible for the abscopal effect.

  3. Yttrium-90 microspheres for the treatment of hepatocellular carcinoma: A review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salem, Riad; Hunter, Russell D.

    2006-10-01

    To present a critical review of yttrium-90 (TheraSphere) for the treatment of hepatocellular carcinoma (HCC). Medical literature databases (Medline, Cochrane Library, and CANCERLIT) were searched for available literature concerning the treatment of HCC with TheraSphere. These publications were reviewed for scientific and clinical validity. Studies pertaining to the use of yttrium-90 for HCC date back to the 1960s. The results from the early animal safety studies established a radiation exposure range of 50-100 Gy to be used in human studies. Phase I dose escalation studies followed, which were instrumental in delineating radiation dosimetry and safety parameters in humans. These earlymore » studies emphasized the importance of differential arteriolar density between hypervascular HCC and surrounding liver parenchyma. Current trends in research have focused on advancing techniques to safely implement this technology as an alternative to traditional methods of treating unresectable HCC, such as external beam radiotherapy, conformal beam radiotherapy, ethanol ablation, trans-arterial chemoembolization, and radiofrequency ablation. Yttrium-90 (TheraSphere) is an outpatient treatment option for HCC. Current and future research should focus on implementing multicenter phase II and III trials comparing TheraSphere with other therapies for HCC.« less

  4. Treatment of unresectable intrahepatic cholangiocarcinoma with yttrium-90 radioembolization: a systematic review and pooled analysis.

    PubMed

    Al-Adra, D P; Gill, R S; Axford, S J; Shi, X; Kneteman, N; Liau, S-S

    2015-01-01

    Radioembolization with yttrium-90 microspheres offers an alternative treatment option for patients with unresectable intrahepatic cholangiocarcinoma (ICC). However, the rarity and heterogeneity of ICC makes it difficult to draw firm conclusions about treatment efficacy. Therefore, the goal of the current study is to systematically review the existing literature surrounding treatment of unresectable ICCs with yttrium-90 microspheres and provide a comprehensive review of the current experience and clinical outcome of this treatment modality. We performed a comprehensive search of electronic databases for ICC treatment and identified 12 studies with relevant data regarding radioembolization therapy with yttrium-90 microspheres. Based on pooled analysis, the overall weighted median survival was 15.5 months. Tumour response based on radiological studies demonstrated a partial response in 28% and stable disease in 54% of patients at three months. Seven patients were able to be downstaged to surgical resection. The complication profile of radioembolization is similar to that of other intra-arterial treatment modalities. Overall survival of patients with ICC after treatment with yttrium-90 microspheres is higher than historical survival rates and shows similar survival to those patients treated with systemic chemotherapy and/or trans-arterial chemoembolization therapy. Therefore, the use of yttrium-90 microspheres should be considered in the list of available treatment options for ICC. However, future randomized trials comparing systemic chemotherapy, TACE and local radiation will be required to identify the optimal treatment modality for unresectable ICC. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  5. SPIO-labeled Yttrium Microspheres for MR Imaging Quantification of Transcatheter Intrahepatic Delivery in a Rodent Model

    PubMed Central

    Li, Weiguo; Zhang, Zhuoli; Gordon, Andrew C.; Chen, Jeane; Nicolai, Jodi; Lewandowski, Robert J.; Omary, Reed A.

    2016-01-01

    Purpose To investigate the qualitative and quantitative impacts of labeling yttrium microspheres with increasing amounts of superparamagnetic iron oxide (SPIO) material for magnetic resonance (MR) imaging in phantom and rodent models. Materials and Methods Animal model studies were approved by the institutional Animal Care and Use Committee. The r2* relaxivity for each of four microsphere SPIO compositions was determined from 32 phantoms constructed with agarose gel and in eight concentrations from each of the four compositions. Intrahepatic transcatheter infusion procedures were performed in rats by using each of the four compositions before MR imaging to visualize distributions within the liver. For quantitative studies, doses of 5, 10, 15, or 20 mg 2% SPIO-labeled yttrium microspheres were infused into 24 rats (six rats per group). MR imaging R2* measurements were used to quantify the dose delivered to each liver. Pearson correlation, analysis of variance, and intraclass correlation analyses were performed to compare MR imaging measurements in phantoms and animal models. Results Increased r2* relaxivity was observed with incremental increases of SPIO microsphere content. R2* measurements of the 2% SPIO–labeled yttrium microsphere concentration were well correlated with known phantom concentrations (R2 = 1.00, P < .001) over a broader linear range than observed for the other three compositions. Microspheres were heterogeneously distributed within each liver; increasing microsphere SPIO content produced marked signal voids. R2*-based measurements of 2% SPIO–labeled yttrium microsphere delivery were well correlated with infused dose (intraclass correlation coefficient, 0.98; P < .001). Conclusion MR imaging R2* measurements of yttrium microspheres labeled with 2% SPIO can quantitatively depict in vivo intrahepatic biodistribution in a rat model. © RSNA, 2015 Online supplemental material is available for this article. PMID:26313619

  6. Radioembolization of Symptomatic, Unresectable Neuroendocrine Hepatic Metastases Using Yttrium-90 Microspheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paprottka, Philipp M., E-mail: philipp.paprottka@med.uni-muenchen.de; Hoffmann, Ralf-T.; Haug, Alexander

    2012-04-15

    Purpose: To evaluate safety, efficacy, and symptom-control of radioembolization in patients with unresectable liver metastases from neuroendocrine tumors (NETLMs). Materials and Methods: Forty-two patients (mean age of 62 years) with treatment-refractory NETLMs underwent radioembolization using yttrium-90 ({sup 90}Y) resin microspheres. Posttreatment tumor response was assessed by cross-sectional imaging using the Response Evaluation Criteria in Solid Tumors (RECIST) and tumor-marker levels. Laboratory and clinical toxicities and clinical symptoms were monitored. Results: The median activity delivered was 1.63 GBq (range 0.63-2.36). Imaging follow-up using RECIST at 3-month follow-up demonstrated partial response, stable disease, and progressive disease in 22.5, 75.0, and 2.5% ofmore » patients, respectively. In 97.5% of patients, the liver lesions appeared hypovascular or partially necrotic. The mean follow-up was 16.2 months with 40 patients (95.2%) remaining alive. The median decrease in tumor-marker levels at 3 months was 54.8% (chromogranin A) and 37.3% (serotonin), respectively. There were no acute or delayed toxicities greater than grade 2 according to Common Terminology Criteria for Adverse Events [CTCAE (v3.0)]. No radiation-induced liver disease was noted. Improvement of clinical symptoms 3 months after treatment was observed in 36 of 38 symptomatic patients. Conclusion: Radioembolization with {sup 90}Y-microspheres is a safe and effective treatment option in patients with otherwise treatment-refractory NETLMs. Antitumoral effect is supported by good local tumor control, decreased tumor-marker levels, and improved clinical symptoms. Further investigation is warranted to define the role of radioembolization in the treatment paradigm for NETLMs.« less

  7. Hepatic Abscess After Yttrium-90 Radioembolization for Islet-Cell Tumor Hepatic Metastasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mascarenhas, Neil B., E-mail: neilmascarenhas1@gmail.co; Mulcahy, Mary F.; Lewandowski, Robert J.

    2010-06-15

    Infectious complications after yttrium-90 (y-90) radioembolization of hepatic tumors are rare. Most reports describe hepatic abscesses as complications of other locoregional therapies, such as transcatheter arterial embolization or chemoembolization. These usually occur in patients with a history of biliary intervention and present several weeks after treatment. We report a case of hepatic abscess formed immediately after y-90 radioembolization of a hepatic metastasis in a patient who had no history of previous biliary instrumentation.

  8. Hanford isotope project strategic business analysis yttrium-90 (Y-90)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-10-01

    The purpose of this analysis is to address the short-term direction for the Hanford yttrium-90 (Y-90) project. Hanford is the sole DOE producer of Y-90, and is the largest repository for its source in this country. The production of Y-90 is part of the DOE Isotope Production and Distribution (IP and D) mission. The Y-90 is ``milked`` from strontium-90 (Sr-90), a byproduct of the previous Hanford missions. The use of Sr-90 to produce Y-90 could help reduce the amount of waste material processed and the related costs incurred by the clean-up mission, while providing medical and economic benefits. The costmore » of producing Y-90 is being subsidized by DOE-IP and D due to its use for research, and resultant low production level. It is possible that the sales of Y-90 could produce full cost recovery within two to three years, at two curies per week. Preliminary projections place the demand at between 20,000 and 50,000 curies per year within the next ten years, assuming FDA approval of one or more of the current therapies now in clinical trials. This level of production would incentivize private firms to commercialize the operation, and allow the government to recover some of its sunk costs. There are a number of potential barriers to the success of the Y-90 project, outside the control of the Hanford Site. The key issues include: efficacy, Food and Drug Administration (FDA) approval and medical community acceptance. There are at least three other sources for Y-90 available to the US users, but they appear to have limited resources to produce the isotope. Several companies have communicated interest in entering into agreements with Hanford for the processing and distribution of Y-90, including some of the major pharmaceutical firms in this country.« less

  9. Quantitative and Qualitative Assessment of Yttrium-90 PET/CT Imaging

    PubMed Central

    Büsing, Karen-Anett; Schönberg, Stefan O.; Bailey, Dale L.; Willowson, Kathy; Glatting, Gerhard

    2014-01-01

    Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with 90Y labeled microspheres. The aim of this work was to image and quantify 90Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia). A NEMA IEC body phantom containing 6 fillable spheres (10–37 mm ∅) was used to measure the 90Y distribution with a Biograph mCT PET/CT (Siemens, Erlangen, Germany) with time-of-flight (TOF) acquisition. A sphere to background ratio of 8∶1, with a total 90Y activity of 3 GBq was used. Measurements were performed for one week (0, 3, 5 and 7 d). he acquisition protocol consisted of 30 min-2 bed positions and 120 min-single bed position. mages were reconstructed with 3D ordered subset expectation maximization (OSEM) and point spread function (PSF) for iteration numbers of 1–12 with 21 (TOF) and 24 (non-TOF) subsets and CT based attenuation and scatter correction. Convergence of algorithms and activity recovery was assessed based on regions-of-interest (ROI) analysis of the background (100 voxels), spheres (4 voxels) and the central low density insert (25 voxels). For the largest sphere, the recovery coefficient (RC) values for the 30 min –2-bed position, 30 min-single bed and 120 min-single bed were 1.12±0.20, 1.14±0.13, 0.97±0.07 respectively. For the smaller diameter spheres, the PSF algorithm with TOF and single bed acquisition provided a comparatively better activity recovery. Quantification of Y-90 using Biograph mCT PET/CT is possible with a reasonable accuracy, the limitations being the size of the lesion and the activity concentration present. At this stage, based on our study, it seems advantageous to use different protocols depending on the size of the lesion. PMID:25369020

  10. Process for the separation and purification of yttrium-90 for medical applications

    DOEpatents

    Horwitz, P.E.; Dietz, M.L.

    1994-11-29

    An extraction chromatographic method for the preparation of [sup 90]Y of high chemical and radiochemical purity is disclosed. After an initial purification of a [sup 90]Sr stock solution and a suitable period of [sup 90]Y ingrowth, the solution is passed through a series of strontium-selective chromatographic columns, each of which lowers the [sup 90]Sr content of the mixture by a factor of about 10[sup 3]. The [sup 90]Y remaining is freed from any residual [sup 90]Sr, from its [sup 90]Zr daughter, and from any remaining impurities by passing the sample through a final column designed to selectively retain yttrium. 5 figures.

  11. Process for the separation and purification of yttrium-90 for medical applications

    DOEpatents

    Horwitz, Philip E.; Dietz, Mark L.

    1994-01-01

    An extraction chromatographic method for the preparation of .sup.90 Y of high chemical and radiochemical purity is disclosed. After an initial purification of a .sup.90 Sr stock solution and a suitable period of .sup.90 Y ingrowth, the solution is passed through a series of strontium-selective chromatographic columns, each of which lowers the .sup.90 Sr content of the mixture by a factor of about 10.sup.3. The .sup.90 Y remaining is freed from any residual .sup.90 Sr, from its .sup.90 Zr daughter, and from any remaining impurities by passing the sample through a final column designed to selectively retain yttrium.

  12. Chemical reactivation of fluorescein isothiocyanate immunofluorescence-labeled resin-embedded samples

    NASA Astrophysics Data System (ADS)

    Li, Longhui; Rao, Gong; Lv, Xiaohua; Chen, Ruixi; Cheng, Xiaofeng; Wang, Xiaojun; Zeng, Shaoqun; Liu, Xiuli

    2018-02-01

    Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that the weakened fluorescence could be recovered by reactivating the fluorophore with alkaline buffer. We extended this idea to immunofluorescence-labeling technology. We showed that the fluorescence of pH-sensitive fluorescein isothiocyanate (FITC) was quenched after resin embedding but reactivated after treating by alkaline buffer. We observed 138.5% fluorescence preservation ratio of reactivated state, sixfold compared with the quenched state in embedding resin, which indicated its application for fluorescence imaging of high signal-to-background ratio. Furthermore, we analyzed the chemical reactivation mechanism of FITC fluorophore. This work would show a way for high-resolution imaging of immunofluorescence-labeled samples embedded in resin.

  13. A process for the separation and purification of yttrium-90 for medical applications

    DOEpatents

    Horwitz, P.E.; Dietz, M.L.

    1993-01-01

    An extraction chromatographic method for the preparation of {sup 90}Y of high chemical and radiochemical purity is disclosed. After an initial purification of a {sup 90}Sr stock solution and a suitable period of {sup 90}Y ingrowth, the solution is passed through a series of strontium-selective chromatographic columns, each of which lowers the {sup 90}Sr content of the mixture by a factor of about 10{sup 3}. The {sup 90}Y remaining is freed from any residual {sup 90}Sr, from its {sup 90}Zr daughter, and from any remaining impurities by passing the sample through a final column designed to selectively retain yttrium.

  14. Radiographic Response to Yttrium-90 Radioembolization in Anterior Versus Posterior Liver Segments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ibrahim, Saad M.; Lewandowski, Robert J.; Ryu, Robert K.

    2008-11-15

    The purpose of our study was to determine if preferential radiographic tumor response occurs in tumors located in posterior versus anterior liver segments following radioembolization with yttrium-90 glass microspheres. One hundred thirty-seven patients with chemorefractory liver metastases of various primaries were treated with yttrium-90 glass microspheres. Of these, a subset analysis was performed on 89 patients who underwent 101 whole-right-lobe infusions to liver segments V, VI, VII, and VIII. Pre- and posttreatment imaging included either triphasic contrast material-enhanced CT or gadolinium-enhanced MRI. Responses to treatment were compared in anterior versus posterior right lobe lesions using both RECIST and WHO criteria.more » Statistical comparative studies were conducted in 42 patients with both anterior and posterior segment lesions using the paired-sample t-test. Pearson correlation was used to determine the relationship between pretreatment tumor size and posttreatment tumor response. Median administered activity, delivered radiation dose, and treatment volume were 2.3 GBq, 118.2 Gy, and 1,072 cm{sup 3}, respectively. Differences between the pretreatment tumor size of anterior and posterior liver segments were not statistically significant (p = 0.7981). Differences in tumor response between anterior and posterior liver segments were not statistically significant using WHO criteria (p = 0.8557). A statistically significant correlation did not exist between pretreatment tumor size and posttreatment tumor response (r = 0.0554, p = 0.4434). On imaging follow-up using WHO criteria, for anterior and posterior regions of the liver, (1) response rates were 50% (PR = 50%) and 45% (CR = 9%, PR = 36%), and (2) mean changes in tumor size were -41% and -40%. In conclusion, this study did not find evidence of preferential radiographic tumor response in posterior versus anterior liver segments treated with yttrium-90 glass microspheres.« less

  15. Radiographic response to yttrium-90 radioembolization in anterior versus posterior liver segments.

    PubMed

    Ibrahim, Saad M; Lewandowski, Robert J; Ryu, Robert K; Sato, Kent T; Gates, Vanessa L; Mulcahy, Mary F; Kulik, Laura; Larson, Andrew C; Omary, Reed A; Salem, Riad

    2008-01-01

    The purpose of our study was to determine if preferential radiographic tumor response occurs in tumors located in posterior versus anterior liver segments following radioembolization with yttrium-90 glass microspheres. One hundred thirty-seven patients with chemorefractory liver metastases of various primaries were treated with yttrium-90 glass microspheres. Of these, a subset analysis was performed on 89 patients who underwent 101 whole-right-lobe infusions to liver segments V, VI, VII, and VIII. Pre- and posttreatment imaging included either triphasic contrast material-enhanced CT or gadolinium-enhanced MRI. Responses to treatment were compared in anterior versus posterior right lobe lesions using both RECIST and WHO criteria. Statistical comparative studies were conducted in 42 patients with both anterior and posterior segment lesions using the paired-sample t-test. Pearson correlation was used to determine the relationship between pretreatment tumor size and posttreatment tumor response. Median administered activity, delivered radiation dose, and treatment volume were 2.3 GBq, 118.2 Gy, and 1,072 cm(3), respectively. Differences between the pretreatment tumor size of anterior and posterior liver segments were not statistically significant (p = 0.7981). Differences in tumor response between anterior and posterior liver segments were not statistically significant using WHO criteria (p = 0.8557). A statistically significant correlation did not exist between pretreatment tumor size and posttreatment tumor response (r = 0.0554, p = 0.4434). On imaging follow-up using WHO criteria, for anterior and posterior regions of the liver, (1) response rates were 50% (PR = 50%) and 45% (CR = 9%, PR = 36%), and (2) mean changes in tumor size were -41% and -40%. In conclusion, this study did not find evidence of preferential radiographic tumor response in posterior versus anterior liver segments treated with yttrium-90 glass microspheres.

  16. Radiochemistry, pre-clinical studies and first clinical investigation of 90Y-labeled hydroxyapatite (HA) particles prepared utilizing 90Y produced by (n,γ) route.

    PubMed

    Vimalnath, K V; Chakraborty, Sudipta; Rajeswari, A; Sarma, H D; Nuwad, Jitendra; Pandey, Usha; Kamaleshwaran, K; Shinto, Ajit; Dash, Ashutosh

    2015-05-01

    The scope of using no carrier added (NCA) (90)Y [T(1/2) = 64.1 h, Eβ(max) = 2.28 MeV] obtained from (90)Sr/(90)Y generator in radiation synovectomy (RSV) is widely accepted. In the present study, the prospect of using (90)Y produced by (n,γ) route in a medium flux research reactor for use in RSV was explored. Yttrium-90 was produced by thermal neutron irradiation of Y(2)O(3) target at a neutron flux of ~1×10(14) n/cm(2).s for 14 d. The influence of various experimental parameters were systematically investigated and optimized to arrive at the most favorable conditions for the formulation of (90)Y labeled hydroxyapatite (HA) using HA particles of 1-10 μm size range. An optimized kit formulation strategy was developed for convenient one-step compounding of (90)Y-HA, which is easily adaptable at hospital radiopharmacy. The pre-clinical biological evaluation of (90)Y-HA particles was studied by carrying out biodistribution and bioluminiscence imaging studies in Wistar rats. The first clinical investigation using the radiolabeled preparation was performed on a patient suffering from chronic arthritis in knee joint by administering 185 MBq (90)Y-HA formulated at the hospital radiopharmacy deploying the proposed strategy. Yttrium-90 was produced with a specific activity of 851 ± 111 MBq/mg and radionuclidic purity of 99.95 ± 0.02%. (90)Y-labeled HA particles (185 ± 10 MBq doses) were formulated in high radiochemical purity (>99%) and excellent in vitro stability. The preparation showed promising results in pre-clinical studies carried out in Wistar rats. The preliminary results of the first clinical investigation of (90)Y-HA preparation in a patient with rheumatoid arthritis in knee joints demonstrated the effectiveness of the formulation prepared using (90)Y produced via (n,γ) route in the management of the disease. The studies revealed that effective utilization of (90)Y produced via (n,γ) route in a medium flux research reactor coupled with the developed

  17. Experience with indium-111 and yttrium-90-labeled somatostatin analogs.

    PubMed

    Virgolini, I; Traub, T; Novotny, C; Leimer, M; Füger, B; Li, S R; Patri, P; Pangerl, T; Angelberger, P; Raderer, M; Burggasser, G; Andreae, F; Kurtaran, A; Dudczak, R

    2002-01-01

    lung cancer ((99m)Tc-depreotide), indicating high diagnostic cabability of this type of receptor tracers. Consequently to their use as receptor imaging agents, hSSTR recognizing radioligands have also been implemented for experimental receptor-targeted radionuclide therapy. Beneficial results were reported for high-dose treatment with (111)In-DTPA-DPhe(1)-octreotide, based on the emission of Auger electrons. The Phase IIa study "MAURITIUS" (Multicenter Analysis of a Universal Receptor Imaging and Treatment Initiative, a eUropean Study) showed in progressive cancer patients (therapy entry criteria) with a calculated tumor dose > 10 Gy / GBq (90)Y-DOTA-lanreotide, the proof-of-principle for treating tumor patients with peptide receptor imaging agents. In the "MAURITIUS" study, cummulative treatment doses up to 200 mCi (90)Y-DOTA-lanreotide were given as short-term infusion. Overall treatment results in 70 patients indicated stable tumor disease in 35% of patients and regressive tumor disease in 10% of tumor patients with different tumor entities expressing hSSTR. No acute or chronic severe hematological toxicity, change in renal or liver function parameters due to (90)Y-DOTA-lanreotide treatment, were reported. (90)Y-DOTA-DPhe(1)-Tyr(3)-octreotide may show a higher tumor uptake in neuroendocrine tumor lesions and may therefore be superior for treatment in patients with neuroendocrine tumors. However, there is only limited excess to long-term and survival data at present. Potential indications for (90Y-DOTA-lanreotide are radioiodine-negative thyroid cancer, hepatocellular cancer and lung cancer. Besides newer approaches and recent developments of 188)Re-labeled radioligands, no clinical results on the treatment response are yet available. In conclusion, several radioligands have been implemented on the basis of peptide receptor recognition throughout the last decade. A plentitude of preclinical data and clinical studies confirm their potential use in diagnosis as well as

  18. Factors associated with increased incidence of severe toxicities following yttrium-90 resin microspheres in the treatment of hepatic malignancies.

    PubMed

    Roberson Ii, John D; McDonald, Andrew M; Baden, Craig J; Lin, Chee Paul; Jacob, Rojymon; Burnett Iii, Omer L

    2016-03-14

    To further define variables associated with increased incidences of severe toxicities following administration of yttrium-90 ((90)Y) microspheres. Fifty-eight patients undergoing 79 treatments were retrospectively assessed for development of clinical and laboratory toxicity incidence following (90)Y administration. Severe toxicity events were defined using Common Terminology Criteria for Adverse Events version 4.03 and defined as grade ≥ 3. Univariate logistic regression analyses were used to evaluate the effect of different factors on the incidence of severe toxicity events. Multicollinearity was assessed for all factors with P < 0.1 using Pearson correlation matrices. All factors not excluded due to multicollinearity were included in a multivariate logistic regression model for each measurement of severe toxicity. Severe (grade ≥ 3) toxicities occurred following 21.5% of the 79 treatments included in our analysis. The most common severe laboratory toxicities were severe alkaline phosphatase (17.7%), albumin (12.7%), and total bilirubin (10.1%) toxicities. Decreased pre-treatment albumin (OR = 26.2, P = 0.010) and increased pre-treatment international normalized ratio (INR) (OR = 17.7, P = 0.048) were associated with development of severe hepatic toxicity. Increased pre-treatment aspartate aminotransferase (AST; OR = 7.4, P = 0.025) and decreased pre-treatment hemoglobin (OR = 12.5, P = 0.025) were associated with severe albumin toxicity. Increasing pre-treatment model for end-stage liver disease (MELD) score (OR = 1.8, P = 0.033) was associated with severe total bilirubin toxicity. Colorectal adenocarcinoma histology was associated with severe alkaline phosphatase toxicity (OR = 5.4, P = 0.043). Clinicians should carefully consider pre-treatment albumin, INR, AST, hemoglobin, MELD, and colorectal histology when choosing appropriate candidates for (90)Y microsphere therapy.

  19. Radiosynovectomy in haemophilic synovitis of elbows and ankles: Is the effectiveness of yttrium-90 and rhenium-186 different?

    PubMed

    Rodriguez-Merchan, E C; De La Corte-Rodriguez, H

    2016-04-01

    Radiosynovectomy (RS) reduces the number of haemarthroses and the synovial size in chronic haemophilic synovitis. The purpose of this study was to quantitatively compare the effectiveness of two types of RS (yttrium-90 vs. rhenium-186) in terms of the objective improvement of haemarthroses and synovial size. Seventy RSs were performed in 70 joints (44 elbows, 26 ankles) of 70 haemophiliacs diagnosed with chronic synovitis. Yttrium-90 was used in 21 joints and rhenium-186 was used in 49 joints. The mean patient age was 20.61 years. RS resulted in significant improvement in the three variables studied (six months before RS vs. six months after RS), namely in the number of episodes of haemarthrosis (67.8% improvement); the size of the synovium as measured by means of a clinical scale (43.8% improvement) and imaging techniques in millimetres (26.7% improvement). We did not find significant statistical differences between yttrium-90 and rhenium-186 regarding their efficacy. No correlation was found between the results and other variables: age, joint (ankle or elbow), presence or absence of radiological involvement, type of haemophilia (A or B), grade of haemophilia (mild, moderate or severe), previous haematological treatment (on demand or prophylaxis), and the presence or absence of inhibitor Yttrium-90 RS and rhenium-186 RS were equally effective in reducing the number of haemarthroses and the size of the synovium in ankles and elbows in the short-term (6 months). No correlation was found between the results and other patients' characteristics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Liver Resection for Colorectal Hepatic Metastases after Systemic Chemotherapy and Selective Internal Radiation Therapy with Yttrium-90 Microspheres: A Systematic Review.

    PubMed

    Baltatzis, Minas; Siriwardena, Ajith K

    2018-06-08

    Selective internal radiation therapy (SIRT) using yttrium-90 resin microspheres has been used together with systemic chemotherapy to treat patients with unresectable liver metastases. This study undertook the first systematic pooled assessment of the case profile, treatment and outcome in patients with initially inoperable colorectal hepatic metastases undergoing resection after systemic chemotherapy and SIRT. A systematic review of the literature was performed using Medline and Embase for publications between January 1998 and August 2017. Keywords and MESH headings "SIRT", "Yttrium-99 radio embolization" and "liver metastases" were used. Reports on patients undergoing liver resection after SIRT for colorectal liver metastases were included. Case reports, reviews and papers without original data were excluded. The study protocol was registered with PROSPERO, (registration number: CRD42017072374). The study population comprised of 120 patients undergoing liver resection after chemotherapy and SIRT. The conversion rate to hepatectomy in previously unresectable patients was 13.6% (109 of 802). All studies report a single application of SIRT. The interval from SIRT to surgery ranged from 39 days to 9 months. Overall, there were 4 (3.3%) deaths after hepatectomy in patients treated by chemotherapy and SIRT. This large pooled report of patients undergoing hepatectomy for colorectal liver metastases after chemotherapy and SIRT shows that 13.6% of patients with initially inoperable disease undergo resection with low procedure-related mortality. © 2018 S. Karger AG, Basel.

  1. Y-90-DOTA-hLL2: An Agent for Radioimmunotherapy of Non-Hodgkin's Lymphoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Griffiths, Gary L.; Govindan, Serengulam V.; Sharkey, Robert M.

    2003-01-01

    The goal of this work was to determine an optimal radioimmunotherapy agent for non-Hodgkin's lymphoma. We established the stability profile of yttrium-90-labeled humanized LL2 (hLL2) monoclonal antibody prepared with different chelating agents, and from these data estimated the improvement using the most stable yttrium-90 chelate-hLL2 complex. Methods: The complementary-determining region- (cdr)-grafted (humanized) anti-CD22 mAb, hLL2 (epratuzumab), was conjugated to derivatives of DTPA and 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (DOTA). The conjugates were labeled with Y-90 and tested against a 10,000-fold molar excess of free DTPA and against human serum. The conjugates were also labeled with Y-88 and compared for biodistribution in normal andmore » lymphoma xenograft-bearing athymic mice. In vivo data were analyzed for uptake of yttrium in bone and washed bone when either the DOTA or the Mx-DTPA chelates were used, and dosimetry calculations were made for each. Results: Y-90-DOTA -mAb were stable to either DTPA or serum challenge. DTPA complexes of hLL2 lost 3-4% of Y-90 (days 1-4) and 10-15% thereafter. In vivo, stability differences showed lower Y-90 uptake in bone using DOTA. Absorbed doses per 37 MBq (1 mCi) Y-90-mAb were 3555 and 5405 cGy for bone, and 2664 and 4524 cGy for washed-bone for 90Y-DOTA-hLL2 and 90Y-MxDTPA-hLL2, respectively, amounting to 52% and 69.8% increases in absorbed radiation doses for bone and washed-bone when switching from a DOTA to a Mx-DTPA chelate. Conclusion: Y-90-hLL2 prepared with the DOTA chelate represents a preferred agent for RAIT of non-Hodgkin's lymphoma, with an in vivo model demonstrating a large reduction in bone-deposited yttrium, as compared to yttrium-90-hLL2 agents prepared with open-chain DTPA-type chelating agents. Dosimetry suggests that this will result in a substantial toxicological advantage for a DOTA-based hLL2 conjugate.« less

  2. Chemoembolic Hepatopulmonary Shunt Reduction to Allow Safe Yttrium-90 Radioembolization Lobectomy of Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaba, Ron C., E-mail: rgaba@uic.edu; VanMiddlesworth, Kyle A.

    2012-12-15

    Yttrium-90 ({sup 90}Y) radioembolization represents an emerging transcatheter treatment option for the management of hepatocellular carcinoma (HCC). Elevation of the hepatopulmonary shunt fraction risks nontarget radiation to the lungs and may limit the use of {sup 90}Y therapy in patients with locally advanced disease with vascular invasion, who often demonstrate increased shunting. We present two cases in which patients with HCC and portal vein invasion resulting in elevated hepatopulmonary shunt fractions underwent chemoembolic shunt closure to allow safe {sup 90}Y radioembolization. Both patients demonstrated excellent tumor response and patient survival. On this basis, we propose a role for chemoembolic reductionmore » of the lung shunt fraction before {sup 90}Y radioembolization in patients with extensive tumor-related hepatopulmonary shunting.« less

  3. Complete eradication of hepatic metastasis from colorectal cancer by Yttrium-90 SIRT

    PubMed Central

    Garrean, Sean; Muhs, Amanda; Bui, James T; Blend, Michael J; Owens, Charles; Helton, William S; Espat, N Joseph

    2007-01-01

    Yttrium-90 (Y-90) radioembolization, also known as selective internal radiation therapy (SIRT), is a regional hepatic therapy used in the treatment of unresectable colorectal cancer (CRC) liver metastases. In SIRT, Y-90 impregnated microspheres are injected into the VASCULAR SUPPLY of hepatic tumor, leading to selective irradiation and necrosis of tumor TISSUE. While several studies demonstrate improved local control and survival with SIRT, the specific indications for this therapy have yet to be defined. Typically, SIRT is given in combination with chemotherapy as multimodal treatment for unresectable hepatic CRC. However, it HAS ALSO FOUND INCREASING USE as a salvage therapy in chemo-refractory patients. Herein, the authors describe their experience with SIRT as “stand alone” therapy in a surgically-prohibitive, chemotherapy naive patient with hepatic CRC metastasis. The results suggest that Y-90 SIRT may have potential applications beyond its usual role as a palliative or salvage therapy for unresectable hepatic CRC. PMID:17589957

  4. [Intracoronary brachytherapy with strontium/yttrium-90. Initial experiences in Germany].

    PubMed

    Silber, S; von Rottkay, P; Gielow, A; Schneider, A; Bauer, A; Schöfer, H

    1998-09-01

    Restenosis after PTCA is still an unresolved problem and occurs in approximately 30% of our patients despite a stent implantation rate of up to 63%. Intracoronary brachytherapy has the potential to counteract the proliferative component of restenosis as well as to prevent shrinking of the coronary artery. Two years ago, we applied for the license to use the Novoste Beta-Cath system. This is the first report of its use in Germany. Attaining the license was complicated by the facts that this device did not yet have CE-certification (MPG section 17), that brachytherapy is not yet an approved method of treatment (StrSchV section 41), the report of the BfS and the approval by an accredited ethical committee. The application becomes even more complicated by the amount demanded by the LfU for insurance: 1 Million DM for each individual patient (AtDeckV section 15). The final local inspection needs to be performed by an expert from the LfAS (StrSchV section 76). Strontium-90 decays into Yttrium-90 with a half-life time of approximately 28 years. Yttrium-90, too, is a pure beta-emitter with a shorter half-life time of approximately 64 hours and a considerably higher electron energy of maximum 2.27 MeV. Yttrium-90 is the therapeutic agent. The radiation source of the Beta-Cath system consists of 12 single, separate cylinders (pellets, seeds) with a total length of 3 cm. The activity of the total train is approximately 1.3 to 1.5 GBq (35 to 40 mCi). For verification of the dose rate provided by the manufacturer, we performed a check using the GafChromic film. The test dose (exactly 2 mm from the center of the long axis of the activity train) was 150 Gy. We obtained the following results for the optical density: reference source: 0.29 +/- 0.01, source C: 0.318 +/- 0.013 and source D: 0.317 +/- 0.028. For a dose rate of e.g. 0.083 Gy/s, the radiation times are 169 s for a dose of 14 Gy (vessel diameter 2.7 to 3.35 mm) or 217 s for 18 Gy (vessel diameter 3.36 to 4.0 mm

  5. Current Role of Selective Internal Irradiation With Yttrium-90 Microspheres in the Management of Hepatocellular Carcinoma: A Systematic Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lau, Wan Yee, E-mail: josephlau@cuhk.edu.hk; Lai, Eric C.H.; Leung, Thomas W.T.

    2011-10-01

    Purpose: This article reviews the role of selective internal irradiation (SIR) with yttrium-90 ({sup 90}Y) microspheres for hepatocellular carcinoma (HCC). Methods and Materials: Studies were identified by searching Medline and PubMed databases for articles from 1990 to 2009 using the keywords 'selective internal irradiation,' 'hepatocellular carcinoma,' 'therapeutic embolization,' and 'yttrium-90.' Results: {sup 90}Y microspheres are a safe and well-tolerated therapy for unresectable HCC (median survival range, 7 -21.6 months). The evidence was limited to cohort studies and comparative studies with historical control. {sup 90}Y microspheres have been reported to downstage unresectable HCC to allow for salvage treatments with curative intent,more » act as a bridging therapy before liver transplantation, and treat HCC with curative intent for patients who are not surgical candidates because of comorbidities. Conclusions: {sup 90}Y microsphere is recommended as an option of palliative therapy for large or multifocal HCC without major portal vein invasion or extrahepatic spread. It can also be used for recurrent unresectable HCC, as a bridging therapy before liver transplantation, as a tumor downstaging treatment, and as a curative treatment for patients with associated comorbidities who are not candidates for surgery.« less

  6. Fast simulation of yttrium-90 bremsstrahlung photons with GATE.

    PubMed

    Rault, Erwann; Staelens, Steven; Van Holen, Roel; De Beenhouwer, Jan; Vandenberghe, Stefaan

    2010-06-01

    Multiple investigators have recently reported the use of yttrium-90 (90Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging for the dosimetry of targeted radionuclide therapies. Because Monte Carlo (MC) simulations are useful for studying SPECT imaging, this study investigates the MC simulation of 90Y bremsstrahlung photons in SPECT. To overcome the computationally expensive simulation of electrons, the authors propose a fast way to simulate the emission of 90Y bremsstrahlung photons based on prerecorded bremsstrahlung photon probability density functions (PDFs). The accuracy of bremsstrahlung photon simulation is evaluated in two steps. First, the validity of the fast bremsstrahlung photon generator is checked. To that end, fast and analog simulations of photons emitted from a 90Y point source in a water phantom are compared. The same setup is then used to verify the accuracy of the bremsstrahlung photon simulations, comparing the results obtained with PDFs generated from both simulated and measured data to measurements. In both cases, the energy spectra and point spread functions of the photons detected in a scintillation camera are used. Results show that the fast simulation method is responsible for a 5% overestimation of the low-energy fluence (below 75 keV) of the bremsstrahlung photons detected using a scintillation camera. The spatial distribution of the detected photons is, however, accurately reproduced with the fast method and a computational acceleration of approximately 17-fold is achieved. When measured PDFs are used in the simulations, the simulated energy spectrum of photons emitted from a point source of 90Y in a water phantom and detected in a scintillation camera closely approximates the measured spectrum. The PSF of the photons imaged in the 50-300 keV energy window is also accurately estimated with a 12.4% underestimation of the full width at half maximum and 4.5% underestimation of the full width at tenth maximum

  7. The evidence base for 'own label' resin-based dental restoratives.

    PubMed

    Burke, F J Trevor

    2013-01-01

    There is anecdotal evidence that sales of 'own-label' (OL) or 'private label' dental products is increasing, as dentists become more cost conscious in times of economic downturn. However, the purchase of such (less expensive) products could be a false economy if their performance falls below accepted standards. So, while the examination of a resin-based product under research conditions alone may not guarantee success, it could be considered that a material which has been subjected to testing under research conditions will demonstrate its effectiveness under laboratory conditions or reveal its shortcomings; either of these being better than the material not being examined in any way. It was therefore considered appropriate to determine the materials on which research was carried out, with particular reference to OL brands. To determine whether there is a research base behind OL resin-based restorative dental materials.

  8. Outcomes of Radioembolization in the Treatment of Hepatocellular Carcinoma with Portal Vein Invasion: Resin versus Glass Microspheres.

    PubMed

    Biederman, Derek M; Titano, Joseph J; Tabori, Nora E; Pierobon, Elisa S; Alshebeeb, Kutaiba; Schwartz, Myron; Facciuto, Marcelo E; Gunasekaran, Ganesh; Florman, Sander; Fischman, Aaron M; Patel, Rahul S; Nowakowski, Francis S; Kim, Edward

    2016-06-01

    To compare outcomes of yttrium-90 radioembolization performed with resin-based ((90)Y-resin) and glass-based ((90)Y-glass) microspheres in the treatment of hepatocellular carcinoma (HCC) with associated portal vein invasion. A single-center retrospective review (January 2005-September 2014) identified 90 patients ((90)Y-resin, 21; (90)Y-glass, 69) with HCC and ipsilateral portal vein thrombosis (PVT). Patients were stratified according to age, sex, ethnicity, Child-Pugh class, Eastern Cooperative Oncology Group status, α-fetoprotein > 400 ng/mL, extent of PVT, tumor burden, and sorafenib therapy. Outcome variables included clinical and laboratory toxicities (Common Terminology Criteria Adverse Events, Version 4.03), imaging response (modified Response Evaluation Criteria in Solid Tumors), time to progression (TTP), and overall survival (OS). Grade 3/4 bilirubin and aspartate aminotransferase toxicities developed at a 2.8-fold (95% confidence interval [CI], 1.3-6.1) and 2.6-fold (95% CI, 1.1-6.1) greater rate in the (90)Y-resin group. The disease control rate was 37.5% in the (90)Y-resin group and 54.5% in the (90)Y-glass group (P = .39). The median (95% CI) TTP was 2.8 (1.9-4.3) months in the (90)Y-resin group and 5.9 (4.2-9.1) months in the (90)Y-glass group (P = .48). Median (95% CI) survival was 3.7 (2.3-6.0) months in the (90)Y-resin group and 9.4 (7.6-15.0) months in the (90)Y-glass group (hazard ratio, 2.6; 95% CI, 1.5-4.3, P < .001). Additional multivariate predictors of improved OS included age < 65 years, Eastern Cooperative Oncology Group status < 1, α-fetoprotein ≤ 400 ng/mL, and unilobar tumor distribution. Imaging response of (90)Y treatment in patients with HCC and PVT was not significantly different between (90)Y-glass and (90)Y-resin groups. Lower toxicity and improved OS were observed in the (90)Y-glass group. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  9. Peptide receptor radionuclide therapy of treatment-refractory metastatic thyroid cancer using 90Yttrium and 177Lutetium labeled somatostatin analogs: toxicity, response and survival analysis

    PubMed Central

    Budiawan, Hendra; Salavati, Ali; Kulkarni, Harshad R; Baum, Richard P

    2014-01-01

    The overall survival rate of non-radioiodine avid differentiated (follicular, papillary, medullary) thyroid carcinoma is significantly lower than for patients with iodine-avid lesions. The purpose of this study was to evaluate toxicity and efficacy (response and survival) of peptide receptor radionuclide therapy (PRRT) in non-radioiodine-avid or radioiodine therapy refractory thyroid cancer patients. Sixteen non-radioiodine-avid and/or radioiodine therapy refractory thyroid cancer patients, including follicular thyroid carcinoma (n = 4), medullary thyroid carcinoma (n = 8), Hürthle cell thyroid carcinoma (n = 3), and mixed carcinoma (n = 1) were treated with PRRT by using 90Yttrium and/or 177Lutetium labeled somatostatin analogs. 68Ga somatostatin receptor PET/CT was used to determine the somatostatin receptor density in the residual tumor/metastatic lesions and to assess the treatment response. Hematological profiles and renal function were periodically examined after treatment. By using fractionated regimen, only mild, reversible hematological toxicity (grade 1) or nephrotoxicity (grade 1) were seen. Response assessment (using EORTC criteria) was performed in 11 patients treated with 2 or more (maximum 5) cycles of PRRT and showed disease stabilization in 4 (36.4%) patients. Two patients (18.2%) showed partial remission, in the remaining 5 patients (45.5%) disease remained progressive. Kaplan-Meier analysis resulted in a mean survival after the first PRRT of 4.2 years (95% CI, range 2.9-5.5) and median progression free survival of 25 months (inter-quartiles: 12-43). In non-radioiodine-avid/radioiodine therapy refractory thyroid cancer patients, PRRT is a promising therapeutic option with minimal toxicity, good response rate and excellent survival benefits. PMID:24380044

  10. Feasibility assessment of yttrium-90 liver radioembolization imaging using amplitude-based gated PET/CT

    PubMed Central

    Acuff, Shelley N.; Neveu, Melissa L.; Syed, Mumtaz; Kaman, Austin D.; Fu, Yitong

    2018-01-01

    Purpose The usage of PET/computed tomography (CT) to monitor hepatocellular carcinoma patients following yttrium-90 (90Y) radioembolization has increased. Respiratory motion causes liver movement, which can be corrected using gating techniques at the expense of added noise. This work examines the use of amplitude-based gating on 90Y-PET/CT and its potential impact on diagnostic integrity. Patients and methods Patients were imaged using PET/CT following 90Y radioembolization. A respiratory band was used to collect respiratory cycle data. Patient data were processed as both standard and motion-corrected images. Regions of interest were drawn and compared using three methods. Activity concentrations were calculated and converted into dose estimates using previously determined and published scaling factors. Diagnostic assessments were performed using a binary scale created from published 90Y-PET/CT image interpretation guidelines. Results Estimates of radiation dose were increased (P<0.05) when using amplitude-gating methods with 90Y PET/CT imaging. Motion-corrected images show increased noise, but the diagnostic determination of success, using the Kao criteria, did not change between static and motion-corrected data. Conclusion Amplitude-gated PET/CT following 90Y radioembolization is feasible and may improve 90Y dose estimates while maintaining diagnostic assessment integrity. PMID:29351124

  11. Process for separation of zirconium-88, rubidium-83 and yttrium-88

    DOEpatents

    Heaton, Richard C.; Jamriska, Sr., David J.; Taylor, Wayne A.

    1994-01-01

    A process for selective separation of strontium-82 and strontium-85 from proton irradiated molybdenum targets is provided and includes dissolving the molybdenum target in a hydrogen peroxide solution to form a first ion-containing solution, passing the first ion-containing solution through a first cationic resin whereby ions selected from the group consisting of molybdenum, niobium, technetium, selenium, vanadium, arsenic, germanium, zirconium and rubidium remain in the first ion-containing solution while ions selected from the group consisting of rubidium, zinc, beryllium, cobalt, iron, manganese, chromium, strontium, yttrium and zirconium are selectively adsorbed by the first resin, contacting the first resin with an acid solution capable of stripping adsorbed ions from the first cationic exchange resin whereby the adsorbed ions are removed from the first resin to form a second ion-containing solution, evaporating the second ion-containing solution for time sufficient to remove substantially all of the acid and water from the second ion-containing solution whereby a residue remains, dissolving the residue from the evaporated second-ion containing solution in a dilute acid to form a third ion-containing solution, said third ion-containing solution having an acid molarity adapted to permit said ions to be adsorbed by a cationic exchange resin, passing the third ion-containing solution through a second cationic resin whereby the ions are adsorbed by the second resin, contacting the second resin with a dilute sulfuric acid solution whereby the adsorbed ions selected from the group consisting of rubidium, zinc, beryllium, cobalt, iron, manganese, chromium, and zirconium are selectively removed from the second resin, and contacting the second resin with a dilute acid solution whereby the adsorbed strontium ions are selectively removed. Zirconium, rubidium, and yttrium radioisotopes can also be recovered with additional steps.

  12. 21 CFR 341.90 - Professional labeling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Professional labeling. 341.90 Section 341.90 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE COLD, COUGH, ALLERGY, BRONCHODILATOR, AND ANTIASTHMATIC DRUG PRODUCTS FOR OVER-THE-COUNTER...

  13. 21 CFR 341.90 - Professional labeling.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Professional labeling. 341.90 Section 341.90 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE COLD, COUGH, ALLERGY, BRONCHODILATOR, AND ANTIASTHMATIC DRUG PRODUCTS FOR OVER-THE-COUNTER...

  14. 21 CFR 341.90 - Professional labeling.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 5 2014-04-01 2014-04-01 false Professional labeling. 341.90 Section 341.90 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE COLD, COUGH, ALLERGY, BRONCHODILATOR, AND ANTIASTHMATIC DRUG PRODUCTS FOR OVER-THE-COUNTER...

  15. 21 CFR 341.90 - Professional labeling.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 5 2012-04-01 2012-04-01 false Professional labeling. 341.90 Section 341.90 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE COLD, COUGH, ALLERGY, BRONCHODILATOR, AND ANTIASTHMATIC DRUG PRODUCTS FOR OVER-THE-COUNTER...

  16. 21 CFR 341.90 - Professional labeling.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 5 2013-04-01 2013-04-01 false Professional labeling. 341.90 Section 341.90 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE COLD, COUGH, ALLERGY, BRONCHODILATOR, AND ANTIASTHMATIC DRUG PRODUCTS FOR OVER-THE-COUNTER...

  17. Optimization of yttrium-90 PET for simultaneous PET/MR imaging: A phantom study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eldib, Mootaz

    2016-08-15

    Purpose: Positron emission tomography (PET) imaging of yttrium-90 in the liver post radioembolization has been shown useful for personalized dosimetry calculations and evaluation of extrahepatic deposition. The purpose of this study was to quantify the benefits of several MR-based data correction approaches offered by using a combined PET/MR system to improve Y-90 PET imaging. In particular, the feasibility of motion and partial volume corrections were investigated in a controlled phantom study. Methods: The ACR phantom was filled with an initial concentration of 8 GBq of Y-90 solution resulting in a contrast of 10:1 between the hot cylinders and the background.more » Y-90 PET motion correction through motion estimates from MR navigators was evaluated by using a custom-built motion stage that simulated realistic amplitudes of respiration-induced liver motion. Finally, the feasibility of an MR-based partial volume correction method was evaluated using a wavelet decomposition approach. Results: Motion resulted in a large (∼40%) loss of contrast recovery for the 8 mm cylinder in the phantom, but was corrected for after MR-based motion correction was applied. Partial volume correction improved contrast recovery by 13% for the 8 mm cylinder. Conclusions: MR-based data correction improves Y-90 PET imaging on simultaneous PET/MR systems. Assessment of these methods must be studied further in the clinical setting.« less

  18. Labelling of 90Y- and 177Lu-DOTA-Bioconjugates for Targeted Radionuclide Therapy: A Comparison among Manual, Semiautomated, and Fully Automated Synthesis.

    PubMed

    Iori, Michele; Capponi, Pier C; Rubagotti, Sara; Esposizione, Luca Rosario; Seemann, Johanna; Pitzschler, Riccardo; Dreger, Thorsten; Formisano, Debora; Grassi, Elisa; Fioroni, Federica; Versari, Annibale; Asti, Mattia

    2017-01-01

    In spite of the hazard due to the radiation exposure, preparation of 90 Y- and 177 Lu-labelled radiopharmaceuticals is still mainly performed using manual procedures. In the present study the performance of a commercial automatic synthesizer based on disposable cassettes for the labelling of 177 Lu- and 90 Y-DOTA-conjugated biomolecules (namely, DOTATOC and PSMA-617) was evaluated and compared to a manual and a semiautomated approach. The dose exposure of the operators was evaluated as well. More than 300 clinical preparations of both 90 Y- and 177 Lu-labelled radiopharmaceuticals have been performed using the three different methods. The mean radiochemical yields for 90 Y-DOTATOC were 96.2 ± 4.9%, 90.3 ± 5.6%, and 82.0 ± 8.4%, while for 177 Lu-DOTATOC they were 98.3%  ± 0.6, 90.8%  ± 8.3, and 83.1 ± 5.7% when manual, semiautomated, and automated approaches were used, respectively. The mean doses on the whole hands for yttrium-90 preparations were 0.15 ± 0.4 mSv/GBq, 0.04 ± 0.1 mSv/GBq, and 0.11 ± 0.3 mSv/GBq for manual, semiautomated, and automated synthesis, respectively, and for lutetium-177 preparations, they were 0.02 ± 0.008 mSv/GBq, 0.01 ± 0.03 mSv/GBq, and 0.01 ± 0.02 mSv/GBq, respectively. In conclusion, the automated approach guaranteed reliable and reproducible preparations of pharmaceutical grade therapeutic radiopharmaceuticals in a decent RCY. The radiation exposure of the operators remained comparable to the manual approach mainly due to the fact that a dedicated shielding was still not available for the system.

  19. Yttrium-90 radioembolization as a bridge to liver transplantation: a single-institution experience.

    PubMed

    Tohme, Samer; Sukato, Daniel; Chen, Hui-Wei; Amesur, Nikhil; Zajko, Albert B; Humar, Abhinav; Geller, David A; Marsh, James W; Tsung, Allan

    2013-11-01

    To evaluate our experience with the use of yttrium-90 ((90)Y) radioembolization in maintaining potential candidacy and, in some instances, downstaging hepatocellular carcinoma (HCC) that does not meet Milan criteria for liver transplantation. A retrospective review of 20 consecutive patients with HCC who were listed to receive a liver transplant and were treated with (90)Y radioembolization as a sole modality for locoregional "bridge" therapy was performed. Demographics, radiographic and pathologic response, survival, and recurrences were examined. Twenty-two (90)Y treatments were performed in 20 patients before transplantation. Median time from first treatment to transplantation was 3.5 months. HCC in 14 patients met the Milan criteria at the time of the first (90)Y treatment, and HCC in six did not. All cases that originally met the Milan criteria remained within the criteria before transplantation, and two of six patients whose disease did not meet the criteria (33%) had their disease successfully downstaged to meet the criteria. Overall, nine patients (45%) had complete or partial radiologic response to (90)Y radioembolization according to modified Response Evaluation Criteria In Solid Tumors. Complete necrosis of tumor with no evidence of viable tumor on pathologic examination was observed in five patients (36%) whose disease met the Milan criteria. Particularly in regions with long wait list times, (90)Y treatment is effective in maintaining tumor size in potential liver transplantation candidates with HCC. In addition, it can also be considered as a downstaging therapy in select patients before transplantation. © SIR, 2013.

  20. Yttrium-90 and indium-111 labelling, receptor binding and biodistribution of [DOTA0,d-Phe1,Tyr3]octreotide, a promising somatostatin analogue for radionuclide therapy.

    PubMed

    de Jong, M; Bakker, W H; Krenning, E P; Breeman, W A; van der Pluijm, M E; Bernard, B F; Visser, T J; Jermann, E; Béhé, M; Powell, P; Mäcke, H R

    1997-04-01

    In vitro octreotide receptor binding of [111In-DOTA0,d-Phe1, Tyr3]octreotide (111In-DOTATOC) and the in vivo metabolism of 90Y- or 111In-labelled DOTATOC were investigated in rats in comparison with [111In-DTPA0]octreotide [111In-DTPAOC). 111In-DOTATOC was found to have an affinity similar to octreotide itself for the octreotide receptor in rat cerebral cortex microsomes. Twenty-four hours after injection of 90Y- or 111In-labelled DOTATOC, uptake of radioactivity in the octreotide receptor-expressing tissues pancreas, pituitary, adrenals and tumour was a factor of 2-6 that after injection of 111In-DTPAOC. Uptake of labelled DOTATOC in pituitary, pancreas, adrenals and tumour was almost completely blocked by pretreatment with 0.5 mg unlabelled octreotide, indicating specific binding to the octreotide receptors. These findings strongly indicate that 90Y-DOTATOC is a promising radiopharmaceutical for radiotherapy and that 111In-DOTATOC is of potential value for diagnosis of patients with octreotide receptor-positive lesions, such as most neuroendocrine tumours.

  1. Predictive Value of 99mTc-MAA SPECT for 90Y-Labeled Resin Microsphere Distribution in Radioembolization of Primary and Secondary Hepatic Tumors.

    PubMed

    Ilhan, Harun; Goritschan, Anna; Paprottka, Philipp; Jakobs, Tobias F; Fendler, Wolfgang P; Todica, Andrei; Bartenstein, Peter; Hacker, Marcus; Haug, Alexander R

    2015-11-01

    This study analyzed the predictive value of (99m)Tc-labeled macroaggregated albumin ((99m)Tc-MAA) SPECT for (90)Y-labeled resin microsphere therapy (radioembolization) by comparing uptake on pretherapeutic (99m)Tc-MAA SPECT with uptake on posttherapeutic (90)Y-bremsstrahlung SPECT. We included 502 patients (55% male; mean age ± SD, 62 ± 11 y) who underwent radioembolization between 2005 and 2013 because of primary or secondary liver malignancies (colorectal cancer [n = 195, 38.8%], neuroendocrine tumors [n = 77, 15.3%], breast cancer [n = 68, 13.5%], hepatocellular carcinoma [n = 59, 11.8%], cholangiocellular carcinoma [n = 40, 8.0%], or urologic tumors [n = 14, 2.8%]). Manually drawn regions of interest around tumors and adjacent healthy liver tissue for up to 3 lesions per patient on (99m)Tc-MAA and (90)Y-bremsstrahlung scans were used to quantify mean counts per pixel and evaluate the mean tumor-to-background ratio (TBR). Data were given as mean ± SD. Additionally, uptake in lesions on (99m)Tc-MAA and (90)Y-bremsstrahlung scans was graded visually as homogeneously higher than (grade 1), heterogeneously higher than (grade 2), equal to (grade 3), or lower than (grade 4) uptake in normal liver tissue. The Mann-Whitney U test and Spearman correlation were used to evaluate statistically significant differences between (99m)Tc-MAA and (90)Y-bremsstrahlung SPECT. In total, 1,008 lesions were analyzed. Of the 23% (230/1,008) of lesions that had grade 1 uptake on (99m)Tc-MAA SPECT, 81% (186/230) remained grade 1 after radioembolization whereas 16% (37/230) were grade 2. Of the lesions with grade 2 uptake on (99m)Tc-MAA SPECT, 16% had grade 1 uptake and 82% grade 2 uptake after radioembolization. Of the lesions with grade 3 uptake, however, 27% had grade 1 uptake and 47% grade 2 uptake after radioembolization. Even among the lesions with grade 4 uptake on (99m)Tc-MAA SPECT, 21% had grade 1 uptake and 46% grade 2 uptake after radioembolization. The mean TBR on (99m

  2. (90)Y microspheres prepared by sol-gel method, promising medical material for radioembolization of liver malignancies.

    PubMed

    Łada, Wiesława; Iller, Edward; Wawszczak, Danuta; Konior, Marcin; Dziel, Tomasz

    2016-10-01

    A new technology for the production of radiopharmaceutical (90)Y microspheres in the form of spherical yttrium oxide grains obtained by sol-gel method has been described. The authors present and discuss the results of investigations performed in the development of new production technology of yttrium microspheres and determination of their physic-chemical properties. The final product has the structure of spherical yttrium oxide grains with a diameter 25-100μm, is stable and free from contaminants. Irradiation of 20mg samples of grains with diameter of 20-50μm in the thermal neutron flux of 1.7×10(14)cm(-2)s(-1) at the core of MARIA research nuclear reactor allowed to obtain microspheres labelled with the (90)Y isotope on the way of the nuclear reaction (89)Y(n, ɤ)(90)Y. Specific activity of irradiated microspheres has been determined by application of absolute triple to double coincidence ratio method (TDCR) and has been evaluated at 190MBq/mg Y. (90)Y microspheres prepared by the proposed technique can be regarded as a promising medical material for radioembolization of liver malignancies. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Synthesis, Radiolabelling and In Vitro Characterization of the Gallium-68-, Yttrium-90- and Lutetium-177-Labelled PSMA Ligand, CHX-A''-DTPA-DUPA-Pep.

    PubMed

    Baur, Benjamin; Solbach, Christoph; Andreolli, Elena; Winter, Gordon; Machulla, Hans-Jürgen; Reske, Sven N

    2014-04-29

    Since prostate-specific membrane antigen (PSMA) has been identified as a diagnostic target for prostate cancer, many urea-based small PSMA-targeting molecules were developed. First, the clinical application of these Ga-68 labelled compounds in positron emission tomography (PET) showed their diagnostic potential. Besides, the therapy of prostate cancer is a demanding field, and the use of radiometals with PSMA bearing ligands is a valid approach. In this work, we describe the synthesis of a new PSMA ligand, CHX-A''-DTPA-DUPA-Pep, the subsequent labelling with Ga-68, Lu-177 and Y-90 and the first in vitro characterization. In cell investigations with PSMA-positive LNCaP C4-2 cells, KD values of ≤14.67 ± 1.95 nM were determined, indicating high biological activities towards PSMA. Radiosyntheses with Ga-68, Lu-177 and Y-90 were developed under mild reaction conditions (room temperature, moderate pH of 5.5 and 7.4, respectively) and resulted in nearly quantitative radiochemical yields within 5 min.

  4. Synthesis, Radiolabelling and In Vitro Characterization of the Gallium-68-, Yttrium-90- and Lutetium-177-Labelled PSMA Ligand, CHX-A''-DTPA-DUPA-Pep

    PubMed Central

    Baur, Benjamin; Solbach, Christoph; Andreolli, Elena; Winter, Gordon; Machulla, Hans-Jürgen; Reske, Sven N.

    2014-01-01

    Since prostate-specific membrane antigen (PSMA) has been identified as a diagnostic target for prostate cancer, many urea-based small PSMA-targeting molecules were developed. First, the clinical application of these Ga-68 labelled compounds in positron emission tomography (PET) showed their diagnostic potential. Besides, the therapy of prostate cancer is a demanding field, and the use of radiometals with PSMA bearing ligands is a valid approach. In this work, we describe the synthesis of a new PSMA ligand, CHX-A''-DTPA-DUPA-Pep, the subsequent labelling with Ga-68, Lu-177 and Y-90 and the first in vitro characterization. In cell investigations with PSMA-positive LNCaP C4-2 cells, KD values of ≤14.67 ± 1.95 nM were determined, indicating high biological activities towards PSMA. Radiosyntheses with Ga-68, Lu-177 and Y-90 were developed under mild reaction conditions (room temperature, moderate pH of 5.5 and 7.4, respectively) and resulted in nearly quantitative radiochemical yields within 5 min. PMID:24787458

  5. Immune activation underlies a sustained clinical response to Yttrium-90 radioembolisation in hepatocellular carcinoma.

    PubMed

    Chew, Valerie; Lee, Yun Hua; Pan, Lu; Nasir, Nurul J M; Lim, Chun Jye; Chua, Camillus; Lai, Liyun; Hazirah, Sharifah Nur; Lim, Tony Kiat Hon; Goh, Brian K P; Chung, Alexander; Lo, Richard H G; Ng, David; Filarca, Rene L F; Albani, Salvatore; Chow, Pierce K H

    2018-02-13

    Yttrium-90 (Y90)-radioembolisation (RE) significantly regresses locally advanced hepatocellular carcinoma and delays disease progression. The current study is designed to deeply interrogate the immunological impact of Y90-RE, which elicits a sustained therapeutic response. Time-of-flight mass cytometry and next-generation sequencing (NGS) were used to analyse the immune landscapes of tumour-infiltrating leucocytes (TILs), tumour tissues and peripheral blood mononuclear cells (PBMCs) at different time points before and after Y90-RE. TILs isolated after Y90-RE exhibited signs of local immune activation: higher expression of granzyme B (GB) and infiltration of CD8 + T cells, CD56 + NK cells and CD8 + CD56 + NKT cells. NGS confirmed the upregulation of genes involved in innate and adaptive immune activation in Y90-RE-treated tumours. Chemotactic pathways involving CCL5 and CXCL16 correlated with the recruitment of activated GB + CD8 + T cells to the Y90-RE-treated tumours. When comparing PBMCs before and after Y90-RE, we observed an increase in tumour necrosis factor-α on both the CD8 + and CD4 + T cells as well as an increase in percentage of antigen-presenting cells after Y90-RE, implying a systemic immune activation. Interestingly, a high percentage of PD-1 + /Tim-3 + CD8 + T cells coexpressing the homing receptors CCR5 and CXCR6 denoted Y90-RE responders. A prediction model was also built to identify sustained responders to Y90-RE based on the immune profiles from pretreatment PBMCs. High-dimensional analysis of tumour and systemic immune landscapes identified local and systemic immune activation that corresponded to the sustained response to Y90-RE. Potential biomarkers associated with a positive clinical response were identified and a prediction model was built to identify sustained responders prior to treatment. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is

  6. Phase II trial of yttrium-90-DOTA-biotin pretargeted by NR-LU-10 antibody/streptavidin in patients with metastatic colon cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knox, S J.; Goris, M L.; Tempero, M

    A Phase II study of yttrium-90-tetra-azacyclododecanetetra-acetic acid-biotin (Y-90-DOTA-biotin) pretargeted by NR-LU-10 antibody/streptavidin (SA) was performed. The primary objectives of the study were to evaluate the efficacy and safety of this therapy in patients with metastatic colon cancer. Twenty-five patients were treated with a single dose of 110 mCi/m{sup 2} (mean administered dose, 106.5-10.3 mCi/m{sup 2}) of Y-90-DOTA-biotin. There were three components of the therapy. Patients first received NR-LU-10/SA on day 1. A clearing agent (biotin-galactose-human serum albumin) was administered 48 h after the NR-LU-10/SA to remove residual circulating unbound NR-LU-10/SA. Lastly, 24 h after administration of clearing agent, patients receivedmore » biotin-DOTA-labeled with 110 mCi/m{sup 2} Y-90. All three components of the therapy were administered i.v. Both hematological and nonhematological toxicities were observed. Diarrhea was the most frequent grade 4 nonhematological toxicity (16%; with 16% grade 3 diarrhea). Hematological toxicity was less severe with 8% grade 3 and 8% grade 4 neutropenia and 8% grade 3 and 16% grade 4 thrombocytopenia. The overall response rate was 8%. Two partial responders had freedom from progression of 16 weeks. Four patients (16%) had stable disease with freedom from progression of 10-20 weeks. Despite the relatively disappointing results of this study in terms of therapeutic efficacy and toxicity, proof of principle was obtained for the pretargeting approach. In addition, valuable new information was obtained about normal tissue tolerance to low-dose-rate irradiation that will help to provide useful guidelines for future study designs.« less

  7. Method of separation of yttrium-90 from strontium-90

    DOEpatents

    Bray, Lane A.; Wester, Dennis W.

    1996-01-01

    A method for purifying Y-90 from a Sr-90/Y-90 "cow" wherein raw Sr-90/Y-90 source containing impurities is obtained from nuclear material reprocessing. Raw Sr-90/Y-90 source is purified to a fresh Sr-90/Y-90 source "cow" by removing impurities by addition of sodium hydroxide and by removing Cs-137 by further addition of sodium carbonate. The "cow" is set aside to allow ingrowth. An HDEHP organic extractant is obtained from a commercial supplier and further purified by saturation with Cu(II), precipitation with acetone, and washing with nitric acid. The "cow" is then dissolved in nitric acid and the purified HDEHP is washed with nitric acid and scrubbed with either nitric or hydrochloric acid. The dissolved "cow" and scrubbed HDEHP are combined in an organic extraction, separating Y-90 from Sr-90, resulting in a Sr-90/Y-90 concentration ratio of not more than 10(E-7), and a metal impurity concentration of not more than 10 ppm per curie of Y-90. The separated Y-90 may then be prepared for delivery.

  8. Production of Zr-89 using sputtered yttrium coin targets 89Zr using sputtered yttrium coin targets.

    PubMed

    Queern, Stacy Lee; Aweda, Tolulope Aramide; Massicano, Adriana Vidal Fernandes; Clanton, Nicholas Ashby; El Sayed, Retta; Sader, Jayden Andrew; Zyuzin, Alexander; Lapi, Suzanne Elizabeth

    2017-07-01

    An increasing interest in zirconium-89 ( 89 Zr) can be attributed to the isotope's half-life which is compatible with antibody imaging using positron emission tomography (PET). The goal of this work was to develop an efficient means of production for 89 Zr that provides this isotope with high radionuclidic purity and specific activity. We investigated the irradiation of yttrium sputtered niobium coins and compared the yields and separation efficiency to solid yttrium coins. The sputtered coins were irradiated with an incident beam energy of 17.5MeV or 17.8MeV providing a degraded transmitted energy through an aluminum degrader of 12.5MeV or 12.8MeV, respectively, with various currents to determine optimal cyclotron conditions for 89 Zr production. Dissolution of the solid yttrium coin took 2h with 50mL of 2M HCl and dissolution of the sputtered coin took 15-30min with 4mL of 2M HCl. During the separation of 89 Zr from the solid yttrium coins, 77.9 ± 11.2% of the activity was eluted off in an average of 7.3mL of 1M oxalic acid whereas for the sputtered coins, 91 ± 6% was eluted off in an average of 1.2mL of 1M oxalic acid with 100% radionuclidic purity. The effective specific activity determined via DFO-SCN titration from the sputtered coins was 108±7mCi/μmol as compared to 20.3mCi/μmol for the solid yttrium coin production. ICP-MS analysis of the yttrium coin and the sputtered coins showed 99.99% yttrium removed with 178μg of yttrium in the final solution and 99.93-100% of yttrium removed with remaining range of 0-42μg of yttrium in the final solution, respectively. The specific activity calculated for the solid coin and 3 different sputtered coins using the concentration of Zr found via ICP-MS was 140±2mCi/μmol, 300±30mCi/μmol, 410±60mCi/μmol and 1719±5mCi/μmol, respectively. Labeling yields of the 89 Zr produced via sputtered targets for 89 Zr- DFO-trastuzumab were >98%. Overall, these results show the irradiation of yttrium sputtered niobium coins

  9. Method of separation of yttrium-90 from strontium-90

    DOEpatents

    Bray, L.A.; Wester, D.W.

    1996-04-30

    A method is described for purifying Y-90 from a Sr-90/Y-90 ``cow`` wherein raw Sr-90/Y-90 source containing impurities is obtained from nuclear material reprocessing. Raw Sr-90/Y-90 source is purified to a fresh Sr-90/Y-90 source ``cow`` by removing impurities by addition of sodium hydroxide and by removing Cs-137 by further addition of sodium carbonate. The ``cow`` is set aside to allow ingrowth. An HDEHP organic extractant is obtained from a commercial supplier and further purified by saturation with Cu(II), precipitation with acetone, and washing with nitric acid. The ``cow`` is then dissolved in nitric acid and the purified HDEHP is washed with nitric acid and scrubbed with either nitric or hydrochloric acid. The dissolved ``cow`` and scrubbed HDEHP are combined in an organic extraction, separating Y-90 from Sr-90, resulting in a Sr-90/Y-90 concentration ratio of not more than 10(E-7), and a metal impurity concentration of not more than 10 ppm per curie of Y-90. The separated Y-90 may then be prepared for delivery. 1 fig.

  10. Therapeutic equivalence in survival for hepatic arterial chemoembolization and 90Yttrium microspheres (Y90) treatments in unresectable hepatocellular carcinoma: a 2 cohort study

    PubMed Central

    Carr, Brian I.; Kondragunta, Venkateswarlu; Buch, Shama C.; Branch, Robert A.

    2009-01-01

    BACKGROUND Intra-hepatic arterial 90Yttrium (Y90) microspheres (Theraspheres) have been proposed as a less toxic, invasive therapeutic option to trans-hepatic arterial chemoembolization (TACE) for surgically unresectable hepatocellular carcinoma (HCC). TACE has been shown to prolong survival. However, long term survival remains uncertain. METHODS A 2 cohort experience of the treatment of advanced, unresectable and biopsy-proven HCC in North American patients is presented. 691 patients received repetitive cisplatin-based chemoembolization and a following 99 patient cohort with similar treatment criteria, received a planned single dose of Y90. Over this time period, an additional 142 patients were followed without treatment (total: 932 patients). RESULTS Overall survival was slightly better in the Y90 group compared to TACE, median of 11.5 vs. 8.5 months. However, selection criteria indicated a small but significant bias towards milder disease in the Y90 group. Using stratification in a 3 tier model, with cases dichotomized by bilirubin of less than 1.5 mg/dL, patients without PVT or with low alpha-fetoprotein plasma levels of less than 25 units/dL, analysis of survival in clinical subgroups showed that the 2 treatments resulted in similar survival. Similarly, patients with PVT or a high alpha-fetoprotein also had similar survival in the 2 treatment groups. CONCLUSION Given the present evidence of therapeutic equivalence in survival, Y90 and TACE seem to be equivalent regional therapies for patients with unresectable, non-metastatic HCC. PMID:20066715

  11. SU-C-204-01: A Dosimetric Investigation Into the Effects of Yttrium-90 Radioembolization On the GI Tract: In-Vivo and Histological Analysis in An Animal Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pasciak, A; The University of Tennessee Graduate School of Medicine, Knoxville, TN; Nodit, L

    Purpose: In Yttrium-90 (90Y) radioembolization, non-target embolization (NTE) to the stomach or small bowel can result in ulceration, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed-dose endpoints. Methods: Under approval of the University of Tennessee IACUC, 6 female pigs were included in this study. Animals underwent transfemoral angiography and infusion of calibrated dosages of 90Y resin microspheres into arteries supplying part of the gastric wall.more » A 99mTc-MAA simulation study was performed first to determine perfused tissue volume for treatment planning along with contrast-enhanced CT. The pigs were monitored for side effects for 9 weeks, after which time they were euthanized and their upper gastrointestinal tracts were harvested for analysis. Results: 90Y radioembolization was infused resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1–2 small (<3.0 cm2) healed or healing superficial gastric lesions in 5 out of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastric wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed based on microsphere deposition patterns confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a reasonable estimate of absorbed dose. Conclusion: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal

  12. Effectiveness of radiation synovectomy with Yttrium-90 and Samarium-153 particulate hydroxyapatite in rheumatoid arthritis patients with knee synovitis: a controlled, randomized, double-blinded trial.

    PubMed

    Dos Santos, Marla Francisca; Furtado, Rita Nely Vilar; Konai, Monique Sayuri; Castiglioni, Mario Luiz Vieira; Marchetti, Renata Rosa; Silva, Constancia Pagano Gonçalves; Natour, Jamil

    2011-01-01

    The aim of the present study was to investigate the long-term effectiveness of and tolerance to Yttrium-90 and Samarium-153-particulate hydroxyapatite radiation synovectomy in patients with rheumatoid arthritis (RA) and chronic knee synovitis. Eight-four patients (90 knees) with chronic knee synovitis and RA (according to the American College of Rheumatology criteria) participated in a controlled, double-blinded trial. Patients were randomized to receive an intra-articular injection with either 5 mCi Yttrium-90 plus 40 mg of triamcinolone hexacetonide (Y/TH Group), 15 mCi Samarium-153 hydroxyapatite plus 40 mg of triamcinolone hexacetonide (Sm/TH Group), or 40 mg triamcinolone hexacetonide alone (Control Group). Blinded examination at baseline, 1, 4, 12, 32, and 48 weeks post-intervention included a visual analog scale for joint pain and swelling, morning stiffness, range of motion, knee circumference, Likert scale, percentage of improvement, Stanford Health Assessment Questionnaire, Lequesne index, use of non-steroidal anti-inflammatory drugs and corticosteroids, events and adverse effects, calls to the physician, and hospital visits. There were three withdrawals prior to the injections. Regarding the pain, there was a significantly better response in the Y/TH Group versus the Sm/TH Group at T1 (p = 0.025) and versus TH alone at T48 (p = 0.026). The Sm/TH group had more adverse effects (p = 0.042), but these were mild and transitory. For the pain parameter alone, Yttrium-90 radiosynovectomy associated to TH proved superior to Samarium-153 hydroxyapatite radiosynovectomy associated to TH at T1 and to synovectomy with TH at T48. No other statistically significant inter-group differences were detected.

  13. High removal performance of a magnetic FPA90-Cl anion resin for bromate and coexisting precursors: kinetics, thermodynamics, and equilibrium studies.

    PubMed

    Xu, Zhengming; Han, Dexia; Li, Yuan; Zhang, Pingling; You, Lijun; Zhao, Zhengang

    2018-04-23

    In this study, the FPA90-Cl resin was magnetized with supported Fe 3 O 4 particles using a chemical co-precipitation method and its removal performance of bromate and coexisting precursors was explored. The magnetized FPA90-Cl resin was structurally characterized by SEM, FT-IR, and XRD. The effects of the initial concentrations, temperature, and resin dosage on bromate and bromide ion removal in drinking water were investigated using batch experiments. The magnetized FPA90-Cl resin exhibited a high removal efficiency for bromate and bromide ions at three initial concentrations, and the residual bromate concentrations were under the maximum contaminant level (MCL) of 10 μg L -1 after 80 min. The adsorption data of bromate and bromide ion could be well described by a pseudo-first-order kinetic model (R 2  ˃ 0.98). The bromate removal alone was further studied by varying the initial solution pH, temperature, and competitive anions. The results showed that the magnetized FPA90-Cl resin could be used over a wide pH range (4.0-9.0). The maximum sorption capacity of the magnetized FPA90-Cl resin for bromate reached 132.83 mg g -1 at 298 K. The Freundlich and Redlich-Peterson isotherm models fit the bromate adsorption equilibrium better (R 2  ˃ 0.99) than the Langmuir isotherm model (R 2  ˃ 0.98). The thermodynamic analysis showed that the bromate adsorption process was endothermic. The negative ΔG and positive ΔS indicated that the process was spontaneous and that randomness increased after adsorption, respectively. The competition of coexisting anions with bromate was in the order of SO 4 2-  > CO 3 2-  > Cl -  > NO 3 -  > HCO 3 -  > PO 4 3- . Additionally, the magnetized FPA90-Cl resin could maintain a high bromate and bromide ion adsorption capacity after five cycles of regeneration by a 0.1 M NaCl solution. Graphical abstract ᅟ.

  14. Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu; Nambiar, Ashwin, E-mail: uvashwin@gmail.com; Hagspiel, Lauren M., E-mail: lmh4gg@virginia.edu

    2013-06-15

    Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Fivemore » arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.« less

  15. Experiments in Radiochemistry: Paper Electrophorectic Separation of Superscript 90 Sr and Superscript 90 Y.

    ERIC Educational Resources Information Center

    Miekely, N.; Roldao, L. A.

    1982-01-01

    Using different supporting electrolytes, the influence of complex-forming equilibria on migration velocities of strontium-90 and yttrium-90 can be demonstrated in this experiment. Includes procedures and materials needed. (SK)

  16. Rapid sequential determination of Pu, 90Sr and 241Am nuclides in environmental samples using an anion exchange and Sr-Spec resins.

    PubMed

    Lee, M H; Ahn, H J; Park, J H; Park, Y J; Song, K

    2011-02-01

    This paper presents a quantitative and rapid method of sequential separation of Pu, (90)Sr and (241)Am nuclides in environmental soil samples with an anion exchange resin and Sr Spec resin. After the sample solution was passed through an anion exchange column connected to a Sr Spec column, Pu isotopes were purified from the anion exchange column. Strontium-90 was separated from other interfering elements by the Sr Spec column. Americium-241 was purified from lanthanides by the anion exchange resin after oxalate co-precipitation. Measurement of Pu and Am isotopes was carried out using an α-spectrometer. Strontium-90 was measured by a low-level liquid scintillation counter. The radiochemical procedure of Pu, (90)Sr and (241)Am nuclides investigated in this study validated by application to IAEA reference materials and environmental soil samples. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Three-year clinical follow-up after strontium-90/yttrium-90 beta-irradiation for the treatment of in-stent coronary restenosis.

    PubMed

    Baierl, Verena; Baumgartner, Simone; Pöllinger, Barbara; Leibig, Marcus; Rieber, Johannes; König, Andreas; Krötz, Florian; Sohn, Hae-Young; Siebert, Uwe; Haimerl, Wolfgang; Dühmke, Eckhart; Theisen, Karl; Klauss, Volker; Schiele, Thomas M

    2005-11-15

    Because late vessel failure has been speculated as a possible limitation of vascular brachytherapy, we conducted a prospective clinical evaluation at 6, 12, 24, and 36 months of follow-up after irradiation with strontium-90/yttrium-90 for in-stent restenosis, regardless of the patient's symptomatic status. We report complete 3-year follow-up data for 106 consecutive patients. The cumulative rate of death at 6, 12, 24, and 36 months was 0.9%, 0.9%, 0.9%, and 1.9% respectively. The corresponding rates for acute ST-elevation myocardial infarction were 2.8%, 4.7%, 4.7%, and 4.7%, respectively. The cumulative rate of late thrombotic occlusion at 6, 12, 24, and 36 months was 3.8%, 4.7%, 4.7%, and 4.7%, respectively. The corresponding rates of target lesion revascularization and target vessel revascularization were 8.5% and 12.3% (p = 0.046), 14.2% (p = 0.157) and 18.0% (p = 0.046), 12.3% and 18.9% (p = 0.008), and 21.7% (p = 0.083) and 29.2% (p = 0.005), respectively. The cumulative rate of all major adverse cardiovascular events at 6, 12, 24, and 36 months was 16.1%, 24.5% (p = 0.003), 27.4% (p = 0.083), and 35.8% (p = 0.003), respectively. In conclusion, these results indicate a delayed and, even in the third year after the index procedure, continued restenotic process after beta irradiation of in-stent restenotic lesions.

  18. Treating and Downstaging Hepatocellular Carcinoma in the Caudate Lobe with Yttrium-90 Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ibrahim, Saad M.; Kulik, Laura; Baker, Talia

    2012-10-15

    Purpose: This study was designed to determine the technical feasibility, safety, efficacy, and potential to downstage patients to within transplantation criteria when treating patients with hepatocellular carcinoma (HCC) of the caudate lobe using Y90 radioembolization. Methods: During a 4-year period, 8 of 291 patients treated with radioembolization for unresectable HCC had disease involving the caudate lobe. All patients were followed for treatment-related clinical/biochemical toxicities, serum tumor marker response, and treatment response. Imaging response was assessed with the World Health Organization (WHO) and European Association for the Study of the Liver (EASL) classification schemes. Pathologic response was reported as percent necrosismore » at explantation. Results: Caudate lobe radioembolization was successfully performed in all eight patients. All patients presented with both cirrhosis and portal hypertension. Half were United Network for Organ Sharing (UNOS) stage T3 (n = 4, 50%). Fatigue was reported in half of the patients (n = 4, 50%). One (13%) grade 3/4 bilirubin toxicity was reported. One patient (13%) showed complete tumor response by WHO criteria, and three patients (38%) showed complete response using EASL guidelines. Serum AFP decreased by more than 50% in most patients (n = 6, 75%). Four patients (50%) were UNOS downstaged from T3 to T2, three of who underwent transplantation. One specimen showed histopathologic evidence of 100% complete necrosis, and two specimens demonstrated greater than 50% necrosis. Conclusions: Radioembolization with yttrium-90 appears to be a feasible, safe, and effective treatment option for patients with unresectable caudate lobe HCC. It has the potential to downstage patients to transplantation.« less

  19. EMBOLIZATION OF DOG PROSTATES WITH YTTRIUM-90 MICROSPHERES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greene, W.M.

    1963-10-01

    Experiments exploring means for the protection of adjacent normal tissue while delivering a destructive dose of radiation to malignant tissue were conducted. By injection of radioactive ceramic spheres or particles, too large to pass through capillaries or arteriovenous shunts, relatively high doses of radiation can be distributed homogeneously to a circumscribed area. Attempts were made to determine the uniformity of distribution and the radiation effect of varying doses of spheres injected into the arterial supply of the dog prostate. Nonradioactive and radioactive ceramic microspheres of 60 mu dia were used since this size exceeds the diameter of capillaries and arteriovenousmore » shunts. Yttrium-90 microspheres of varying radioactivity were used. Doses injected into right and left hypogastric arteries varied from 0.69 to 28.4 mc/side (92-1260 mc/ g prostate). Homogeneous distribution of radioactivity within the prostate was demonstrated by autoradiography. Distribution to some other organs (rectum, penis, and bladder) occurred because arterial supply to these structures was not isolated and occluded. The amount of radioactivity found in the lungs suggested more venous drainage in some cases than seemed apparent, and because of the infarctions of pelvic organs may have leaked radioactive spheres into the venous circuit. In 6 of the 8 dogs which died prematurely (2 to 7 days after surgery) obvious infarction of the prostate and in some other pelvic structures had occurred. That the radioactivity contributed to the infarction is suggested by the results in the dogs which received large doses of radioactivity (18.9 and 28.4 mc per side) in minimal amounts of spheres (100to 150 mg per side). The intensely concentrated radioactivity within the arteriolar lumens may have caused vasculitis and subsequent thrombosis. Although homogeneous destruction of the prostate gland occurred, the effect of a given dose ranged unpredictably through three groups: no apparent

  20. Activating Photodynamic Therapy in vitro with Cerenkov Radiation Generated from Yttrium-90

    PubMed Central

    Hartl, Brad A.; Hirschberg, Henry; Marcu, Laura; Cherry, Simon R.

    2017-01-01

    The translation of photodynamic therapy (PDT) to the clinical setting has primarily been limited to easily accessible and/or superficial diseases, for which traditional light delivery can be performed noninvasively. Cerenkov radiation, as generated from medically relevant radionuclides, has been suggested as a means to deliver light to deeper tissues noninvasively to overcome this depth limitation. This article investigates the utility of Cerenkov radiation, as generated from the radionuclide yttrium-90, for activating the PDT process using clinically approved aminolevulinic acid at 1.0 mm and also the more efficient porphyrin-based photosensitizer mesotetraphenylporphine with two sulfonate groups on adjacent phenyl rings (TPPS2a) at 1.2 μM. Experiments were conducted with monolayer cultured glioma and breast tumor cell lines. Although aminolevulinic acid proved to be ineffective for generating a therapeutic effect at all but the highest activity levels, TPPS2a produced at least a 20% therapeutic effect at activities ranging from 6 to 60 μCi/well for the C6 glioma cell line. Importantly, these results demonstrate for the first time, to our knowledge, that Cerenkov radiation generated from a radionuclide can be used to activate PDT using clinically relevant photosensitizers. These results therefore provide evidence that it may be possible to generate a phototherapeutic effect in vivo using Cerenkov radiation and clinically relevant photosensitizers. PMID:27481495

  1. Model-Based Radiation Dose Correction for Yttrium-90 Microsphere Treatment of Liver Tumors With Central Necrosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ching-Sheng; Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan; Lin, Ko-Han

    Purpose: The objectives of this study were to model and calculate the absorbed fraction {phi} of energy emitted from yttrium-90 ({sup 90}Y) microsphere treatment of necrotic liver tumors. Methods and Materials: The tumor necrosis model was proposed for the calculation of {phi} over the spherical shell region. Two approaches, the semianalytic method and the probabilistic method, were adopted. In the former method, the range--energy relationship and the sampling of electron paths were applied to calculate the energy deposition within the target region, using the straight-ahead and continuous-slowing-down approximation (CSDA) method. In the latter method, the Monte Carlo PENELOPE code wasmore » used to verify results from the first method. Results: The fraction of energy, {phi}, absorbed from {sup 90}Y by 1-cm thickness of tumor shell from microsphere distribution by CSDA with complete beta spectrum was 0.832 {+-} 0.001 and 0.833 {+-} 0.001 for smaller (r{sub T} = 5 cm) and larger (r{sub T} = 10 cm) tumors (where r is the radii of the tumor [T] and necrosis [N]). The fraction absorbed depended mainly on the thickness of the tumor necrosis configuration, rather than on tumor necrosis size. The maximal absorbed fraction {phi} that occurred in tumors without central necrosis for each size of tumor was different: 0.950 {+-} 0.000, and 0.975 {+-} 0.000 for smaller (r{sub T} = 5 cm) and larger (r{sub T} = 10 cm) tumors, respectively (p < 0.0001). Conclusions: The tumor necrosis model was developed for dose calculation of {sup 90}Y microsphere treatment of hepatic tumors with central necrosis. With this model, important information is provided regarding the absorbed fraction applicable to clinical {sup 90}Y microsphere treatment.« less

  2. Radioimmunotherapy of pancreatic cancer xenografts in nude mice using 90Y-labeled anti-α6β4 integrin antibody

    PubMed Central

    Aung, Winn; Tsuji, Atsushi B.; Sudo, Hitomi; Sugyo, Aya; Ukai, Yoshinori; Kouda, Katsushi; Kurosawa, Yoshikazu; Furukawa, Takako; Saga, Tsuneo

    2016-01-01

    The contribution of integrin α6β4 (α6β4) overexpression to the pancreatic cancer invasion and metastasis has been previously shown. We have reported immunotargeting of α6β4 for radionuclide-based and near-infrared fluorescence imaging in a pancreatic cancer model. In this study, we prepared yttrium-90 labeled anti-α6β4 antibody (90Y-ITGA6B4) and evaluated its radioimmunotherapeutic efficacy against pancreatic cancer xenografts in nude mice. Mice bearing xenograft tumors were randomly divided into 5 groups: (1) single administration of 90Y-ITGA6B4 (3.7MBq), (2) double administrations of 90Y-ITGA6B4 with once-weekly schedule (3.7MBq × 2), (3) single administration of unlabeled ITGA6B4, (4) double administrations of unlabeled ITGA6B4 with once-weekly schedule and (5) the untreated control. Biweekly tumor volume measurements and immunohistochemical analyses of tumors at 2 days post-administration were performed to monitor the response to treatments. To assess the toxicity, body weight was measured biweekly. Additionally, at 27 days post-administration, blood samples were collected through cardiac puncture, and hematological parameters, hepatic and renal functions were analyzed. Both 90Y-ITGA6B4 treatment groups showed reduction in tumor volumes (P < 0.04), decreased cell proliferation marker Ki-67-positive cells and increased DNA damage marker p-H2AX-positive cells, compared with the other groups. Mice treated with double administrations of 90Y-ITGA6B4, exhibited myelosuppression. There were no significant differences in hepatic and renal functions between the 2 treatment groups and the other groups. Our results suggest that 90Y-ITGA6B4 is a promising radioimmunotherapeutic agent against α6β4 overexpressing tumors. In the future studies, dose adjustment for fractionated RIT should be considered carefully in order to get the optimal effect while avoiding myelotoxicity. PMID:27246980

  3. Evaluation of microtensile and tensile bond strength tests determining effects of erbium, chromium: yttrium-scandium-gallium-garnet laser pulse frequency on resin-enamel bonding.

    PubMed

    Yildirim, T; Ayar, M K; Yesilyurt, C; Kilic, S

    2016-01-01

    The aim of the present study was to compare two different bond strength test methods (tensile and microtensile) in investing the influence of erbium, chromium: yttrium-scandium-gallium-garnet (Er, Cr: YSGG) laser pulse frequency on resin-enamel bonding. One-hundred and twenty-five bovine incisors were used in the present study. Two test methods were used: Tensile bond strength (TBS; n = 20) and micro-TBS (μTBS; n = 5). Those two groups were further split into three subgroups according to Er, Cr: YSGG laser frequency (20, 35, and 50 Hz). Following adhesive procedures, microhybrid composite was placed in a custom-made bonding jig for TBS testing and incrementally for μTBS testing. TBS and μTBS tests were carried out using a universal testing machine and a microtensile tester, respectively. Analysis of TBS results showed that means were not significantly different. For μTBS, the Laser-50 Hz group showed the highest bond strength (P < 0.05), and increasing frequency significantly increased bond strength (P < 0.05). Comparing the two tests, the μTBS results showed higher means and lower standard deviations. It was demonstrated that increasing μTBS pulse frequency significantly improved immediate bond strength while TBS showed no significant effect. It can, therefore, be concluded that test method may play a significant role in determining optimum laser parameters for resin bonding.

  4. 'Own-Label' Versus Branded Commercial Dental Resin Composite Materials: Mechanical And Physical Property Comparisons.

    PubMed

    Shaw, Kathryn; Martins, Ricardo; Hadis, Mohammed Abdul; Burke, Trevor; Palin, William

    2016-09-01

    A majority of dental materials are manufactured by companies who have experience in the field. However, a number of "own label" materials have become available, principally marketed by distributors and other companies with little or no experience in the field. These materials are attractive because of their reduced cost, but they may have no research on which clinicians might base their potential performance. It is therefore the purpose of this work to compare the performance of different batches of a number of "own-label" dental materials with a similar number from manufacturers with experience in the field, using a variety of laboratory test regimes which include filler determination, degree of conversion, flexural strength and flexural modulus, in order to evaluate key material properties. The results indicated that own-label dental resin composites produced similar results to materials from established companies in terms of flexural strength characteristics and degree of conversion. However, a greater batch-to-batch variation in several mechanical and physical properties of the own-label materials was noted. Copyright© 2016 Dennis Barber Ltd.

  5. Cohort study of somatostatin-based radiopeptide therapy with [(90)Y-DOTA]-TOC versus [(90)Y-DOTA]-TOC plus [(177)Lu-DOTA]-TOC in neuroendocrine cancers.

    PubMed

    Villard, Linda; Romer, Anna; Marincek, Nicolas; Brunner, Philippe; Koller, Michael T; Schindler, Christian; Ng, Quinn K T; Mäcke, Helmut R; Müller-Brand, Jan; Rochlitz, Christoph; Briel, Matthias; Walter, Martin A

    2012-04-01

    Radiopeptide therapy is commonly performed with a single radioisotope. We aimed to compare the effectiveness of somatostatin-based radiopeptide therapy with a single versus a combination of radioisotopes. In a cohort study, patients with metastasized neuroendocrine cancer were treated with repeated cycles of (90)yttrium-labeled tetraazacyclododecane-tetraacetic acid modified Tyr-octreotide ([(90)Y-DOTA]-TOC) or with cycles alternating between [(90)Y-DOTA]-TOC and (177)lutetium-labeled DOTA-TOC ([(177)Lu-DOTA]-TOC) until tumor progression or permanent toxicity. Multivariable Cox regression and competing risk regression were used to study predictors of survival and renal toxicity in patients completing three or more treatment cycles. A total of 486 patients completed three or more treatment cycles; 237 patients received [(90)Y-DOTA]-TOC and 249 patients received [(90)Y-DOTA]-TOC + [(177)Lu-DOTA]-TOC. Patients receiving [(90)Y-DOTA]-TOC + [(177)Lu-DOTA]-TOC had a significantly longer survival than patients receiving [(90)Y-DOTA]-TOC alone (5.51 v 3.96 years; hazard ratio, 0.64; 95% CI, 0.47 to 0.88; P = .006). The rates of severe hematologic toxicities (6.3% v 4.4%; P = .25) and severe renal toxicity (8.9% v 11.2%; P = .47) were comparable in both groups. [(90)Y-DOTA]-TOC + [(177)Lu-DOTA]-TOC was associated with improved overall survival compared with [(90)Y-DOTA]-TOC alone in patients completing three or more cycles of treatment. Contrary to the current practice in radiopeptide therapy, our results suggest an advantage of using a combination of radioisotopes.

  6. Intra-articular radioactive yttrium and triamcinolone hexacetonide: an inconclusive trial. Arthritis and Rheumatism Council Multicentre Radiosynoviorthesis Trial Group.

    PubMed

    1984-08-01

    A restricted sequential design multicentre controlled trial of yttrium-90 against triamcinolone intra-articularly was undertaken in patients with rheumatoid arthritis with knee involvement. The trial had to be discontinued because of dwindling recruitment over time. The reasons for this and other features contributing to an inconclusive outcome are noted. This experience lends little encouragement to the idea that yttrium-90 therapy is more or less advantageous than triamcinolone hexacetonide.

  7. Standardization of Procedures for the Preparation of (177)Lu- and (90)Y-labeled DOTA-Rituximab Based on the Freeze-dried Kit Formulation.

    PubMed

    Wojdowska, Wioletta; Karczmarczyk, Urszula; Maurin, Michal; Garnuszek, Piotr; Mikołajczak, Renata

    2015-01-01

    Rituximab when radiolabelled with (177)Lu or (90)Y has been investigated for the treatment of patients with Non-Hodgkin's Lymphoma. In this study, we optimized the preparation of antibody conjugates with chelating agent in the freeze-dried kit. It shortens procedures needed for the successful radiolabeling with lutetium-177 and yttrium-90 and assures reproducible labelling yields. Various molar ratios of Rituximab:DOTA (from 1:5 to 1:100) were used at the conjugation step and different purification method to remove unbound DOTA were investigated (size-exclusion chromatography, dialysis, ultrafiltration). The final monoclonal antibody concentration was quantified by Bradford method, and the number of DOTA molecules was determined by radiolabeling assay using (64)Cu. The specific activity of (177)Lu-DOTA-Rituximab and (90)Y-DOTA-Rituximab were optimized using various amounts of radiometal. Quality control (SE-HPLC, ITLC) and stability study were performed. An average of 4.2 ± 0.8 p-SCN-Bz-DOTA molecules could be randomly conjugated to a single molecule of Rituximab. The ultrafiltration system was the most efficient for purification and resulted in the highest recovery efficiency (77.2%). At optimized conditions the (177)Lu-DOTARituximab and (90)Y-DOTA-Rituximab were obtained with radiochemical purity >99% and specific activity ca. 600 MBq/mg. The radioimmunoconjugates were stable in human serum and 0.9% NaCl. After 72 h of incubation the radiochemical purity of (177)Lu-DOTA-Rituximab decreased to 94% but it was still more than 88% for (90)Y-DOTA-Rituximab. The radioimmunoconjugate showed stability after six months storage at 2 - 8(0)C, as a lyophilized formulation. Our study shows that Rituximab-DOTA can be efficiently radiolabeled with (177)Lu and (90)Y via p-SCN-Bn-DOTA using a freezedried kit.

  8. The behaviour of selected yttrium containing bioactive glass microspheres in simulated body environments.

    PubMed

    Cacaina, D; Ylänen, H; Simon, S; Hupa, M

    2008-03-01

    The study aims at the manufacture and investigation of biodegradable glass microspheres incorporated with yttrium potentially useful for radionuclide therapy of cancer. The glass microspheres in the SiO2-Na2O-P2O5-CaO-K2O-MgO system containing yttrium were prepared by conventional melting and flame spheroidization. The behaviour of the yttrium silicate glass microspheres was investigated under in vitro conditions using simulated body fluid (SBF) and Tris buffer solution (TBS), for different periods of time, according to half-life time of the Y-90. The local structure of the glasses and the effect of yttrium on the biodegradability process were evaluated by Fourier Transform Infrared (FT-IR) spectroscopy and Back Scattered Electron Imaging of Scanning Electron Microscopy (BEI-SEM) equipped with Energy Dispersive X-ray (EDX) analysis. UV-VIS spectrometry and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used for analyzing the release behaviour of silica and yttrium in the two used solutions. The results indicate that the addition of yttrium to a bioactive glass increases its structural stability which therefore, induced a different behaviour of the glasses in simulated body environments.

  9. Comparison of TOF-PET and Bremsstrahlung SPECT Images of Yttrium-90: A Monte Carlo Simulation Study.

    PubMed

    Takahashi, Akihiko; Himuro, Kazuhiko; Baba, Shingo; Yamashita, Yasuo; Sasaki, Masayuki

    2018-01-01

    Yttrium-90 ( 90 Y) is a beta particle nuclide used in targeted radionuclide therapy which is available to both single-photon emission computed tomography (SPECT) and time-of-flight (TOF) positron emission tomography (PET) imaging. The purpose of this study was to assess the image quality of PET and Bremsstrahlung SPECT by simulating PET and SPECT images of 90 Y using Monte Carlo simulation codes under the same conditions and to compare them. In-house Monte Carlo codes, MCEP-PET and MCEP-SPECT, were employed to simulate images. The phantom was a torso-shaped phantom containing six hot spheres of various sizes. The background concentrations of 90 Y were set to 50, 100, 150, and 200 kBq/mL, and the concentrations of the hot spheres were 10, 20, and 40 times of those of the background concentrations. The acquisition time was set to 30 min, and the simulated sinogram data were reconstructed using the ordered subset expectation maximization method. The contrast recovery coefficient (CRC) and contrast-to-noise ratio (CNR) were employed to evaluate the image qualities. The CRC values of SPECT images were less than 40%, while those of PET images were more than 40% when the hot sphere was larger than 20 mm in diameter. The CNR values of PET images of hot spheres of diameter smaller than 20 mm were larger than those of SPECT images. The CNR values mostly exceeded 4, which is a criterion to evaluate the discernibility of hot areas. In the case of SPECT, hot spheres of diameter smaller than 20 mm were not discernable. On the contrary, the CNR values of PET images decreased to the level of SPECT, in the case of low concentration. In almost all the cases examined in this investigation, the quantitative indexes of TOF-PET 90 Y images were better than those of Bremsstrahlung SPECT images. However, the superiority of PET image became critical in the case of low activity concentrations.

  10. Intra-articular radioactive yttrium and triamcinolone hexacetonide: an inconclusive trial. Arthritis and Rheumatism Council Multicentre Radiosynoviorthesis Trial Group.

    PubMed Central

    1984-01-01

    A restricted sequential design multicentre controlled trial of yttrium-90 against triamcinolone intra-articularly was undertaken in patients with rheumatoid arthritis with knee involvement. The trial had to be discontinued because of dwindling recruitment over time. The reasons for this and other features contributing to an inconclusive outcome are noted. This experience lends little encouragement to the idea that yttrium-90 therapy is more or less advantageous than triamcinolone hexacetonide. PMID:6383234

  11. Prospective study to determine early hypertrophy of the contra-lateral liver lobe after unilobar, Yttrium-90, selective internal radiation therapy in patients with hepatocellular carcinoma.

    PubMed

    Teo, Jin Yao; Allen, John Carson; Ng, David Chee Eng; Abdul Latiff, Julianah Bee; Choo, Su Pin; Tai, David Wai-Meng; Low, Albert Su Chong; Cheah, Foong Koon; Chang, Jason Pik Eu; Kam, Juinn Huar; Lee, Victor T W; Chung, Alexander Yaw Fui; Chan, Chung Yip; Chow, Pierce Kah Hoe; Goh, Brian K P

    2018-05-01

    Liver resection is a major curative option in patients presenting with hepatocellular carcinoma. An inadequate functional liver remnant is a major limiting factor precluding liver resection. In recent years, hypertrophy of the functional liver remnant after selective internal radiation therapy hypertrophy has been observed, but the degree of hypertrophy in the early postselective internal radiation therapy period has not been well studied. We conducted a prospective study on patients undergoing unilobar, Yttrium-90 selective internal radiation therapy for hepatocellular carcinoma to evaluate early hypertrophy at 4-6 weeks and 8-12 weeks after selective internal radiation therapy. In the study, 24 eligible patients were recruited and had serial volumetric measurements performed. The median age was 66 years (38-75 years). All patients were either Child-Pugh Class A or B, and 6/24 patients had documented, clinically relevant portal hypertension; 15 of the 24 patients were hepatitis B positive. At 4-6 weeks, modest hypertrophy was seen (median 3%; range -12 to 42%) and this increased at 8-12 weeks (median 9%; range -12 to 179%). No preprocedural factors predictive of hypertrophy were identified. Hypertrophy of the functional liver remnant after selective internal radiation therapy with Yttrium-90 occurred in a subset of patients but was modest and unpredictable in the early stages. Selective internal radiation therapy cannot be recommended as a standard treatment modality to induce early hypertrophy for patients with hepatocellular carcinoma. (Surgery 2017;160:XXX-XXX.). Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Risk of Liver Abscess Formation in Patients with Prior Biliary Intervention Following Yttrium-90 Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cholapranee, Aurada; Houten, Diana van; Deitrick, Ginna

    PurposePatients without a competent sphincter of Oddi due to prior surgical or endoscopic therapy are at high risk for liver abscess following chemoembolization despite aggressive antimicrobial prophylaxis. We examined a cohort of such patients undergoing Y-90 resin radioembolization and compared them to a cohort of chemoembolized patients.MethodsReview of our quality-assurance database identified 24 radioembolizations performed in 16 patients with prior biliary intervention. An aggressive prophylactic regimen of oral levofloxacin and metronidazole 2 days pre-procedure continuing for 14 days after, oral neomycin/erythromycin bowel prep the day before, and IV levofloxacin/metronidazole the day of treatment was prescribed. Patients underwent resin microsphere radioembolization dosed accordingmore » to the BSA method. Patients had clinical, imaging, and laboratory assessment 1 month after each treatment, and then every 3 months. The chemoembolization cohort consisted of 13 patients with prior biliary intervention who had undergone 24 chemoembolization procedures.ResultsNo radioembolization patient developed an abscess. In the cohort of chemoembolized patients who received the same prophylaxis, liver abscess occurred following 3 of 24 (12.5 %) procedures in 3 of 13 (23 %) patients, one fatal.ConclusionsThis preliminary experience suggests that the risk of liver abscess among patients with prior biliary intervention may be lower following radioembolization than chemoembolization, which could potentially expand treatment options in this high-risk population.« less

  13. Yttrium-90 DOTA peptide chimeric L6 toxicity and therapeutic potential in nude mice with human breast tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeNardo, S.J.; Zhong, G.R.; Miers, L.A.

    1994-05-01

    Chimeric L6 MoAb (ChL6) as I-131 ChL6 has shown therapeutic promise for radioimmunotherapy in breast cancer patients. In order to enhance this therapeutic potential, we have developed an yttrium-90 (Y-90) ChL6 radiopharmaceutical by conjugating Y-90 DOTA peptide to ChL6 using DOTA-Gly-3L(p-isothiocyanato)-Phe-NH2. This DOTA peptide forms neutral complexes with trivalent metals allowing excess chelating agents and divalent metal complexes to be removed by ion exchange chromatography prior to conjugation, thus yielding a high Y-90/DOTA ratio on the final immune conjugate. Groups of 9-10 nude mice bearing subcutaneous 40-200 mg HBT 3477 xenographs were given 150,250,350,400,450 or 500 {mu}Ci of Y-90 DOTAmore » peptide ChL6 (specific activity 1.1-3.5 {mu}Ci/{mu}g). Live cell immunoreactivity was 73-80% and 100% Y-90 moved with ChL6 on SEC3000 HPLC and TLC. Peripheral blood counts, weight, tumor size, blood and body clearance of Y-90 were monitored for 10 weeks. Whole body autoradiography was performed at 1,3 and 5 days post injection at the 250 and 450 {mu}Ci dose levels. No mouse that received less than 450 {mu}Ci of Y-90 died. The LD50/30 was 479 {mu}Ci. The nadirs of RBC, WBC and platelets were 10-20 days post 479 {mu}Ci. The nadirs of RBC, WBC and platelets were 10-20 days post injection. The depth of the nadir was dose dependent but occured in all groups. In the lowest dose group having substantial tumor response (350{mu}Ci) mean tumor volume decreased by >50% and 5 of 19 tumors completely regressed over the 10 week follow-up. This is the greatest LD50/30 for Y-90 immunoconjugate reported in nude mice to date. These results confirm the significance of the biodistribution and autoradiographic studies demonstrating tumor uptake of 18 {plus_minus} 8% ID/gm with 3/1 tumor to liver and 8/1 tumor to bone ratios 1, 3, and 5 days post injection.« less

  14. Embolisation of the Gastroduodenal Artery is Not Necessary in the Presence of Reversed Flow Before Yttrium-90 Radioembolisation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daghir, Ahmed A., E-mail: ahmeddaghir@doctors.net.uk; Gungor, Hatice; Haydar, Ali A.

    2012-08-15

    Introduction: The gastroduodenal artery (GDA) is usually embolised to avoid nontarget dispersal before yttrium-90 (Y{sup 90}) radioembolisation to treat liver metastases. In a minority of patients, there is retrograde flow in the GDA. The purpose of this study was to determine if there is any increased risk from maintaining a patent GDA in patients with reversed flow. Materials and Methods: A retrospective review was performed of all patients undergoing Y{sup 90} radioembolisation at our institution. The incidence of toxicities arising from nontarget radioembolisation by way of the GDA (gastric/duodenal ulceration, gastric/duodenal bleeding, and pancreatitis) and death occurring within 2 monthsmore » of treatment were compared between the reversed and the antegrade GDA groups. Results: Ninety-two patients underwent preliminary angiography. Reversed GDA flow was found on angiography in 14.1% of cases; the GDA was not embolised in these patients. The GDA was coiled in 55.7% of patients with antegrade GDA flow to prevent inadvertent dispersal of radioembolic material. There was no increased toxicity related to nontarget dispersal by way of the GDA, or increased early mortality, in patients with reversed GDA flow (P > 0.05). Conclusion: In patients with reversed GDA flow, maintenance of a patent GDA before administration of Y{sup 90} radioembolisation does not increase the risk of toxicity from nontarget dispersal. Therapeutic injection, with careful monitoring to identify early vascular stasis, may be safely performed beyond the origin of the patent GDA. A patent GDA with reversed flow provides forward drive for infused particles and may allow alternative access to the hepatic circulation.« less

  15. Determination of strontium-90 in milk samples using a controlled precipitation clean-up step prior to ion-chromatography.

    PubMed

    Cobb, J; Warwick, P; Carpenter, R C; Morrison, R T

    1995-12-01

    Strontium-90 may be determined by beta-counting its yttrium-90 daughter following separation by ion-chromatography, using a three column system comprising a chelating concentrator column, a cation-exchange column and an anion-exchange separator column. The column system has previously been applied to the determination of strontium-90 in water and urine samples. The applicability of the system to the analysis of milk is hampered by the large concentrations of calcium present, which significantly reduces the extraction of yttrium-90 by the concentrator column. A maximum of approximately 200 mg of calcium can be present for the successful extraction of yttrium-90, which greatly limits the quantity of milk that can be analysed. The quantity of milk analysed can be increased by the inclusion of a controlled precipitation step prior to the ion-chromatographic separation. The precipitation is carried out on acid digested milk samples by the addition of ammonia solution until the addition of one drop causes a reduction in pH resulting in the precipitation of calcium hydrogenphosphate. Under these conditions, approximately 20% of the calcium present in the original milk sample is precipitated, yttrium-90 is precipitated whereas strontium-90 is not precipitated. Dissolution of the precipitate, followed by separation of yttrium-90 using the ion-chromatography system facilitates the analysis of a litre of milk with recoveries of greater than 80%.

  16. [Contralateral hepatic hypertrophy following unilateral yttrium-90 radioembolization : Implications for liver surgery].

    PubMed

    Garlipp, B; Seidensticker, M; Jechorek, D; Ptok, H; Bruns, C J; Ricke, J

    2016-05-01

    Preservation of an adequate future liver remnant (FLR) is the principal limitation to liver surgery in patients with primary or secondary liver malignancies. Hence, methods to increase the volume of the FLR in preparation for liver resection are gaining in importance. In addition to the traditional methods for induction of FLR hypertrophy, such as portal vein embolization (PVE) or portal vein ligation (PVL) with or without parenchymal dissection (ALPPS, in situ split), radioembolization (RE) using yttrium-90 microspheres also leads to a volume increase of non-embolized liver parenchyma. This review outlines its potential role as an alternative procedure for induction of liver hypertrophy. Synopsis and critical discussion of the available literature on the mechanisms of induction of liver hypertrophy, the advantages and drawbacks of the traditional methods, and current research on volume changes associated with RE as well as their implications for possible clinical use in preparation for liver surgery. Both PVE and PVL can achieve a substantial contralateral volume gain of up to 70 %. The development of contralateral hypertrophy can be accelerated by dissecting the liver parenchyma along the intended plane of resection in addition to PVL (in situ split). Compared to these methods, RE achieves less contralateral liver hypertrophy; however, this effect should not be disregarded as RE provides effective treatment of ipsilateral liver tumors along with induction of hypertrophy and may be associated with a reduced risk of tumor progression compared to PVE and PVL. The available data suggest that RE can complement the armamentarium of methods for induction of FLR hypertrophy in specific situations. Further studies are needed to establish its definitive role for this indication and are in preparation.

  17. Optimized anion exchange column isolation of zirconium-89 ( 89 Zr) from yttrium cyclotron target: Method development and implementation on an automated fluidic platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O’Hara, Matthew J.; Murray, Nathaniel J.; Carter, Jennifer C.

    Zirconium-89 (89Zr), produced by the (p,n) reaction from naturally monoisotopic yttrium (natY), is a promising positron emitting isotope for immunoPET imaging. Its long half-life of 78.4 h is sufficient for evaluating slow physiological processes. A prototype automated fluidic system, coupled to on-line and in-line detectors, has been constructed to facilitate development of new 89Zr purification methodologies. The highly reproducible reagent delivery platform and near-real time monitoring of column effluents allows for efficient method optimization. The separation of Zr from dissolved Y metal targets was evaluated using several anion exchange resins. Each resin was evaluated against its ability to quantitatively capturemore » Zr from a load solution that is high in dissolved Y. The most appropriate anion exchange resin for this application was identified, and the separation method was optimized. The method is capable of a high Y decontamination factor (>105) and has been shown to separate Fe, an abundant contaminant in Y foils, from the 89Zr elution fraction. Finally, the performance of the method was evaluated using cyclotron bombarded Y foil targets. The separation method was shown to achieve >95% recovery of the 89Zr present in the foils. The 89Zr eluent, however, was in a chemical matrix not immediately conducive to labeling onto proteins. The main intent of this study was to develop a tandem column 89Zr purification process, wherein the anion exchange column method described here is the first separation in a dual-column purification process.« less

  18. Quantitative Comparison of PET and Bremsstrahlung SPECT for Imaging the In Vivo Yttrium-90 Microsphere Distribution after Liver Radioembolization

    PubMed Central

    Elschot, Mattijs; Vermolen, Bart J.; Lam, Marnix G. E. H.; de Keizer, Bart; van den Bosch, Maurice A. A. J.; de Jong, Hugo W. A. M.

    2013-01-01

    Background After yttrium-90 (90Y) microsphere radioembolization (RE), evaluation of extrahepatic activity and liver dosimetry is typically performed on 90Y Bremsstrahlung SPECT images. Since these images demonstrate a low quantitative accuracy, 90Y PET has been suggested as an alternative. The aim of this study is to quantitatively compare SPECT and state-of-the-art PET on the ability to detect small accumulations of 90Y and on the accuracy of liver dosimetry. Methodology/Principal Findings SPECT/CT and PET/CT phantom data were acquired using several acquisition and reconstruction protocols, including resolution recovery and Time-Of-Flight (TOF) PET. Image contrast and noise were compared using a torso-shaped phantom containing six hot spheres of various sizes. The ability to detect extra- and intrahepatic accumulations of activity was tested by quantitative evaluation of the visibility and unique detectability of the phantom hot spheres. Image-based dose estimates of the phantom were compared to the true dose. For clinical illustration, the SPECT and PET-based estimated liver dose distributions of five RE patients were compared. At equal noise level, PET showed higher contrast recovery coefficients than SPECT. The highest contrast recovery coefficients were obtained with TOF PET reconstruction including resolution recovery. All six spheres were consistently visible on SPECT and PET images, but PET was able to uniquely detect smaller spheres than SPECT. TOF PET-based estimates of the dose in the phantom spheres were more accurate than SPECT-based dose estimates, with underestimations ranging from 45% (10-mm sphere) to 11% (37-mm sphere) for PET, and 75% to 58% for SPECT, respectively. The differences between TOF PET and SPECT dose-estimates were supported by the patient data. Conclusions/Significance In this study we quantitatively demonstrated that the image quality of state-of-the-art PET is superior over Bremsstrahlung SPECT for the assessment of the 90Y

  19. Proteomic Identification and Quantification of S-glutathionylation in Mouse Macrophages Using Resin-Assisted Enrichment and Isobaric Labeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su, Dian; Gaffrey, Matthew J.; Guo, Jia

    2014-02-11

    Protein S-glutathionylation (SSG) is an important regulatory posttranslational modification of protein cysteine (Cys) thiol redox switches, yet the role of specific cysteine residues as targets of modification is poorly understood. We report a novel quantitative mass spectrometry (MS)-based proteomic method for site-specific identification and quantification of S-glutathionylation across different conditions. Briefly, this approach consists of initial blocking of free thiols by alkylation, selective reduction of glutathionylated thiols and enrichment using thiol affinity resins, followed by on-resin tryptic digestion and isobaric labeling with iTRAQ (isobaric tags for relative and absolute quantitation) for MS-based identification and quantification. The overall approach was validatedmore » by application to RAW 264.7 mouse macrophages treated with different doses of diamide to induce glutathionylation. A total of 1071 Cys-sites from 690 proteins were identified in response to diamide treatment, with ~90% of the sites displaying >2-fold increases in SSG-modification compared to controls.. This approach was extended to identify potential SSG modified Cys-sites in response to H2O2, an endogenous oxidant produced by activated macrophages and many pathophysiological stimuli. The results revealed 364 Cys-sites from 265 proteins that were sensitive to S-glutathionylation in response to H2O2 treatment. These proteins covered a range of molecular types and molecular functions with free radical scavenging, and cell death and survival included as the most significantly enriched functional categories. Overall the results demonstrate that our approach is effective for site-specific identification and quantification of S-glutathionylated proteins. The analytical strategy also provides a unique approach to determining the major pathways and cell processes most susceptible to glutathionylation at a proteome-wide scale.« less

  20. BCR-ABL1 molecular remission after 90Y-epratuzumab tetraxetan radioimmunotherapy in CD22+ Ph+ B-ALL: proof of principle.

    PubMed

    Chevallier, Patrice; Bodet-Milin, Caroline; Robillard, Nelly; Eugene, Thomas; Menard, Audrey; Le Houerou, Claire; Guillaume, Thierry; Delaunay, Jacques; Escoffre-Barbe, Martine; Wegener, William A; Goldenberg, David M; Kraeber-Bodéré, Francoise

    2013-12-01

    Although targeted therapies are used increasingly in hematologic malignancies, we are unaware of any prior studies of radioimmunotherapy (RAIT) in B-acute lymphoblastic leukemia (ALL), even though this radiosensitive tumor expresses CD22, potentially a good target for this approach. Here, we report a patient with Philadelphia chromosome-positive B-ALL in third relapse who received RAIT with (90) yttrium ((90) Y)-labeled anti-CD22 epratuzumab tetraxetan. Seven weeks after initiating therapy, the patient achieved a BCR-ABL1 molecular remission documented by RT-qPCR, which is now continuing at 6 months while awaiting an allogeneic hematopoietic stem cell transplant. (90) Y-Epratuzumab tetraxetan may be a promising therapeutic option for CD22(+) B-ALL patients. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Comparison of Micro-Leakage from Resin-Modified Glass Ionomer Restorations in Cavities Prepared by Er:YAG (Erbium-Doped Yttrium Aluminum Garnet) Laser and Conventional Method in Primary Teeth

    PubMed Central

    Bahrololoomi, Zahra; Razavi, Forooghosadat; Soleymani, Ali Asghar

    2014-01-01

    Introduction: In recent years, significant developments have been taking place in caries removal and cavity preparation using laser in dentistry. As laser use is considered for cavity preparation, it is necessary to determine the quality of restoration margins. Glass ionomer cements have great applications for conservative restoration in the pediatric field. The purpose of this in vitro study was to compare resin-modified glass ionomer restorations micro-leakage in cavities prepared by Er:YAG (Erbium-Doped Yttrium Aluminum Garnet) laser irradiation and conventional method in primary teeth. Methods: This was an in vitro experimental study. Forty primary canine teeth were divided into 2 groups: group 1 represented cavities prepared by the no. 008 diamond bur, group 2 represented cavities prepared by Er:YAG laser. After cavity preparation, samples were restored by resin-modified glass ionomer. The teeth were thermocycled for 700 cycles, placed in 2% methylene blue for 24h and sectioned in the buccolingual direction. The degree of dye penetration was scored by 3 examiners. Data was analyzed using Mann-Whitney Test. Results: There was no statistical difference in micro-leakage between the two modes of cavity preparation (P=0.862) Conclusion: Since preparing conservative cavities is very important in pediatric dentistry, it is possible to use Er:YAG laser because of its novel and portable technology. However, further investigations of other restorative materials and other laser powers are required. PMID:25653819

  2. Chemical reactivation of quenched fluorescent protein molecules enables resin-embedded fluorescence microimaging

    PubMed Central

    Xiong, Hanqing; Zhou, Zhenqiao; Zhu, Mingqiang; Lv, Xiaohua; Li, Anan; Li, Shiwei; Li, Longhui; Yang, Tao; Wang, Siming; Yang, Zhongqin; Xu, Tonghui; Luo, Qingming; Gong, Hui; Zeng, Shaoqun

    2014-01-01

    Resin embedding is a well-established technique to prepare biological specimens for microscopic imaging. However, it is not compatible with modern green-fluorescent protein (GFP) fluorescent-labelling technique because it significantly quenches the fluorescence of GFP and its variants. Previous empirical optimization efforts are good for thin tissue but not successful on macroscopic tissue blocks as the quenching mechanism remains uncertain. Here we show most of the quenched GFP molecules are structurally preserved and not denatured after routine embedding in resin, and can be chemically reactivated to a fluorescent state by alkaline buffer during imaging. We observe up to 98% preservation in yellow-fluorescent protein case, and improve the fluorescence intensity 11.8-fold compared with unprocessed samples. We demonstrate fluorescence microimaging of resin-embedded EGFP/EYFP-labelled tissue block without noticeable loss of labelled structures. This work provides a turning point for the imaging of fluorescent protein-labelled specimens after resin embedding. PMID:24886825

  3. Activation of photodynamic therapy in vitro with Cerenkov luminescence generated from Yttrium-90 (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Hartl, Brad A.; Hirschberg, Henry; Marcu, Laura; Cherry, Simon R.

    2016-03-01

    Translation of photodynamic therapy to the clinical setting has primarily been limited to easily accessible and/or superficial diseases where traditional light delivery can be performed noninvasively. Cerenkov luminescence, as generated from medically relevant radionuclides, has been suggested as a means to deliver light to deeper tissues noninvasively in order to overcome this depth limitation. We report on the use of Cerenkov luminescence generated from Yttrium-90 as a means to active the photodynamic therapy process in monolayer tumor cell cultures. The current study investigates the utility of Cerenkov luminescence for activating both the clinically relevant aminolevulinic acid at 1.0 mM and also the more efficient photosensitizer TPPS2a at 1.2 µM. Cells were incubated with aminolevulinic acid for 6 hours prior to radionuclide addition, as well as additional daily treatments for three days. TPPS2a was delivered as a single treatment with an 18 hour incubation time before radionuclide addition. Experiments were completed for both C6 glioma cells and MDA-MB-231 breast tumor cells. Although aminolevulinic acid proved ineffective for generating a therapeutic effect at any activity for either cell line, TPPS2a produced at least a 20% therapeutic effect at activities ranging from 6 to 60 µCi/well for the C6 cell line. Current results demonstrate that it may be possible to generate a therapeutic effect in vivo using Cerenkov luminescence to activate the photodynamic therapy process with clinically relevant photosensitizers.

  4. Evaluation of Liver Biomarkers as Prognostic Factors for Outcomes to Yttrium-90 Radioembolization of Primary and Secondary Liver Malignancies.

    PubMed

    Henrie, Adam M; Wittstrom, Kristina; Delu, Adam; Deming, Paulina

    2015-09-01

    The objective of this study was to examine indicators of liver function and inflammation for prognostic value in predicting outcomes to yttrium-90 radioembolization (RE). In a retrospective analysis, markers of liver function and inflammation, biomarkers required to stage liver function and inflammation, and data regarding survival, tumor response, and progression after RE were recorded. Univariate regression models were used to investigate the prognostic value of liver biomarkers in predicting outcome to RE as measured by survival, tumor progression, and radiographic and biochemical tumor response. Markers from all malignancy types were analyzed together. A subgroup analysis was performed on markers from patients with metastatic colorectal cancer. A total of 31 patients received RE from 2004 to 2014. Median survival after RE for all malignancies combined was 13.6 months (95% CI: 6.7-17.6 months). Results from an exploratory analysis of patient data suggest that liver biomarkers, including albumin concentrations, international normalized ratio, bilirubin concentrations, and the model for end-stage liver disease score, possess prognostic value in predicting outcomes to RE.

  5. Early Dose Response to Yttrium-90 Microsphere Treatment of Metastatic Liver Cancer by a Patient-Specific Method Using Single Photon Emission Computed Tomography and Positron Emission Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, Janice M.; Department of Radiation Oncology, Wayne State University, Detroit, MI; Wong, C. Oliver

    2009-05-01

    Purpose: To evaluate a patient-specific single photon emission computed tomography (SPECT)-based method of dose calculation for treatment planning of yttrium-90 ({sup 90}Y) microsphere selective internal radiotherapy (SIRT). Methods and Materials: Fourteen consecutive {sup 90}Y SIRTs for colorectal liver metastasis were retrospectively analyzed. Absorbed dose to tumor and normal liver tissue was calculated by partition methods with two different tumor/normal liver vascularity ratios: an average 3:1 and a patient-specific ratio derived from pretreatment technetium-99m macroaggregated albumin SPECT. Tumor response was quantitatively evaluated from fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography scans. Results: Positron emission tomography showed a significant decrease in total tumor standardizedmore » uptake value (average, 52%). There was a significant difference in the tumor absorbed dose between the average and specific methods (p = 0.009). Response vs. dose curves fit by linear and linear-quadratic modeling showed similar results. Linear fit r values increased for all tumor response parameters with the specific method (+0.20 for mean standardized uptake value). Conclusion: Tumor dose calculated with the patient-specific method was more predictive of response in liver-directed {sup 90}Y SIRT.« less

  6. Lung Shunt Fraction prior to Yttrium-90 Radioembolization Predicts Survival in Patients with Neuroendocrine Liver Metastases: Single-Center Prospective Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ludwig, Johannes M.; Ambinder, Emily McIntosh; Ghodadra, Anish

    ObjectiveTo investigate survival outcomes following radioembolization with Yttrium-90 (Y90) for neuroendocrine tumor liver metastases (NETLMs). This study was designed to assess the efficacy of Y90 radioembolization and to evaluate lung shunt fraction (LSF) as a predictor for survival.MethodsA single-center, prospective study of 44 consecutive patients (median age: 58.5 years, 29.5 % male) diagnosed with pancreatic (52.3 %) or carcinoid (47.7 %) NETLMs from 2006 to 2012 who underwent Y90 radioembolization was performed. Patients’ baseline characteristics, including LSF and median overall survival (OS) from first Y90 radioembolization, were recorded and compared between patients with high (≥10 %) and low (<10 %) LSF. Baseline comparisons were performed usingmore » Fisher’s exact tests for categorical and Mann–Whitney U test for continuous variables. Survival was calculated using the Kaplan–Meier method. Univariate (Wilcoxon rank-sum test) and multivariate analyses (Cox Proportional Hazard Model) for risk factor analysis were performed.ResultsThere was no statistically significant difference in age, gender, race, tumor properties, or previous treatments between patients with high (n = 15) and low (n = 29) LSF. The median OS was 27.4 months (95 %CI 12.73–55.23), with 4.77 months (95 %CI 2.87–26.73) for high and 42.77 months (95 %CI 18.47–59.73) for low LSF (p = 0.003). Multivariate analysis identified high LSF (p = 0.001), total serum bilirubin >1.2 mg (p = 0.016), and lack of pretreatment with octreotide (p = 0.01) as independent prognostic factors for poorer survival. Tumor type and total radiation dose did not predict survival.ConclusionsLSF ≥10 %, elevated bilirubin levels, and lack of pretreatment with octreotide were found to be independent prognostic factors for poorer survival in patients with NETLMs.« less

  7. Complex upper arm reconstruction using an antero-lateral thigh free flap after an extravasation of Yttrium-90-ibritumomab Tiuxetan: A case report and literature review.

    PubMed

    Baus, A; Keilani, C; Bich, C-S; Entine, F; Brachet, M; Duhamel, P; Amabile, J-C; Malfuson, J V; Bey, E

    2018-04-01

    Yttrium-90-Ibritumomab Tiuxetan (Zevalin ® ) is used in the treatment of non- Hodgkin's lymphoma. Extravasation is an iatrogenic complication that is fortunately rare. However, the treatment of this complication is often complex due to the risk of extensive skin necrosis and unpredictable evolution of localized irradiation. This vesicant drug requires emergency management when extravasation occured. Radiations burns have specificities. Therefore, wound coverage involves specific plastic surgical techniques. Here, we report the case of a man presenting a chronic and extensive skin necrosis of upper arm treated with an antero-lateral thigh free flap. Moreover, we compare our experience of Zevalin ® extravasation management to other past publications and propose recommendations to prevent this unacceptable complication. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Absolute measurements of fast neutrons using yttrium.

    PubMed

    Roshan, M V; Springham, S V; Rawat, R S; Lee, P; Krishnan, M

    2010-08-01

    Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f(n) approximately 4.1x10(-4) with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10(8) neutrons per discharge.

  9. Effect of repair resin type and surface treatment on the repair strength of heat-polymerized denture base resin.

    PubMed

    Alkurt, Murat; Yeşil Duymuş, Zeynep; Gundogdu, Mustafa

    2014-01-01

    Acrylic resin denture fracture is common in prosthodontic practice. When fractured denture bases are repaired, recurrent fractures frequently occur at the repair surface interface or adjacent areas. The purpose of this study was to evaluate the effect of different surface treatments on the flexural strength of the acrylic resin denture base repaired with heat-polymerized acrylic resin, autopolymerizing resin, and light-polymerized acrylic resin. Ninety-six specimens of heat-polymerized acrylic resin were prepared according to the American Dental Association Specification No. 12 (65.0 × 10.0 × 2.5 mm) and sectioned into halves to create a repair gap (3.0 × 10 × 2.5 mm). The sectioned specimens were divided into 3 groups according to their repair materials. The specimens from each group were divided into 4 subgroups according to their surface treatments: a control group without any surface treatment; an experimental group treated with methyl methacrylate monomer (MMA group); an experimental group treated with airborne-particle abrasion with aluminum oxide particles of 250-μm particle size (abrasion group); and an experimental group treated with erbium:yttrium-aluminum-garnet laser (laser group). After the surface treatments, the 3 materials were placed into the repair gaps and then polymerized. After all of the specimens had been ground and polished, they were stored in distilled water at 37°C for 1 week and subjected to a 3-point bend test. Data were analyzed with a 2-way analysis of variance, and the Tukey honestly significant difference test was performed to identify significant differences (α=.05). The effects of the surface treatments and repair resins on the surface of the denture base resin were examined with scanning electron microscopy. Significant differences were found among the groups in terms of repair resin type (P<.001). All surface-treated specimens had higher flexural strength than controls, except the surface treated with the methyl

  10. Incidence and risk factors of early arterial blood flow stasis during first radioembolization of primary and secondary liver malignancy using resin microspheres: an initial single-center analysis.

    PubMed

    Pieper, Claus Christian; Willinek, Winfried A; Thomas, Daniel; Ahmadzadehfar, Hojjat; Essler, Markus; Nadal, Jennifer; Wilhelm, Kai E; Schild, Hans Heinz; Meyer, Carsten

    2016-08-01

    To retrospectively determine incidence of early arterial blood flow stasis and its influencing factors during resin-based radioembolization (RE) of liver tumours. Data of patients undergoing resin-based RE from 06/2006-12/2013 were reviewed. Second RE procedures of the same liver lobe were excluded. 90-yttrium dose was calculated according to the body surface area method. Data were categorized according to RE without full dose application because of early stasis and with full dose application. Clinical/procedural characteristics were recorded. Logistic regression was performed to identify associations between clinical/procedural characteristics and early stasis. 362 patients [220 male; mean age 62 years (range 26-90)] underwent 416 RE sessions with early stasis occurring in 103 REs (24.8 %). Highest incidence and degree of stasis were observed in breast cancer metastases [42.6 % (20/47); 55.8 % of mean intended dose administered]. Independent risk factors were: metastasized breast cancer (odds ratio [OR] 2.18, p = 0.02), liver tumour-burden <25 % and 25-50 % (ORs 5.33, 15.64; p < 0.0001), tumour hypovascularity (OR 2.70, p = 0.04), previous bevacizumab therapy (OR 2.79, p = 0.0009) and concurrent chemotherapy (OR 8.69, p < 0.0001). Early stasis was observed in 24.8 % of resin-based REs. In the presence of the identified risk factors, extra care should be taken during microsphere administration. • Early arterial blood flow stasis is a known problem of resin-based RE. • The study showed that early stasis occurs in 25 % of REs. • Several clinical and procedural factors are associated with early stasis. • In patients at risk extra care should be taken during RE.

  11. [(90)Yttrium-DOTA]-TOC response is associated with survival benefit in iodine-refractory thyroid cancer: long-term results of a phase 2 clinical trial.

    PubMed

    Iten, Fabienne; Muller, Beat; Schindler, Christian; Rasch, Helmut; Rochlitz, Christoph; Oertli, Daniel; Maecke, Helmut R; Muller-Brand, Jan; Walter, Martin A

    2009-05-15

    The authors aimed to explore the efficacy of (90)Yttrium-1,4,7,10-tetra-azacyclododecane N,N',N'',N'''-tetraacetic acid [(90)Y-DOTA]-Tyr(3)-octreotide (TOC) in advanced iodine-refractory thyroid cancer. In a phase 2 trial, the authors investigated biochemical response (assessed by serum thyroglobulin levels), survival, and the long-term safety profile of systemic [(90)Y-DOTA]-TOC treatment in metastasized iodine-refractory thyroid cancer. Adverse events were assessed according to the National Cancer Institute criteria. Survival analyses were performed by using multiple regression models. A total of 24 patients were enrolled. A median cumulative activity of 13.0 GBq (range, 1.7-30.3 GBq) was administered. Response was found in 7 (29.2%) patients. Eight (33.3%) patients developed hematologic toxicity grade 1-3, and 4 (16.7%) patients developed renal toxicity grade 1-4. The median survival was 33.4 months (range, 3.6-126.8 months) from time of diagnosis and 16.8 months (range, 1.8-99.1 months) from time of first [(90)Y-DOTA]-TOC treatment. Response to treatment was associated with longer survival from time of diagnosis (hazard ratio [HR], 0.17; 95% confidence interval [CI], 0.03-0.92; P = .04) and from time of first [(90)Y-DOTA]-TOC therapy (HR, 0.20; 95% CI, 0.04-0.94; P = .04). The visual grade of scintigraphic tumor uptake was not associated with treatment response (odds ratio [OR], 0.98; 95% CI, 0.26-3.14; P = 1.00). Response to [(90)Y-DOTA]-TOC in metastasized iodine-refractory thyroid cancer was associated with longer survival. Upcoming trials should aim to increase the number of treatment cycles.

  12. Dense nanocrystalline yttrium iron garnet films formed at room temperature by aerosol deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Scooter D., E-mail: scooter.johnson@nrl.navy.mil; Glaser, Evan R.; Cheng, Shu-Fan

    Highlights: • We deposit yttrium iron garnet films at room temperature using aerosol deposition. • Films are 96% of theoretical density for yttrium iron garnet. • We report magnetic and structural properties post-deposition and post-annealing. • Low-temperature annealing decreases the FMR linewidth. • We discuss features of the FMR spectra at each anneal temperature. - Abstract: We have employed aerosol deposition to form polycrystalline yttrium iron garnet (YIG) films on sapphire at room temperature that are 90–96% dense. We characterize the structural and dynamic magnetic properties of the dense films using scanning electron microscopy, X-ray diffraction, and ferromagnetic resonance techniques.more » We find that the as-deposited films are pure single-phase YIG formed of compact polycrystallites ∼20 nm in size. The ferromagnetic resonance mode occurs at 2829 G with a linewidth of 308 G. We perform a series of successive anneals up to 1000 °C on a film to explore heat treatment on the ferromagnetic resonance linewidth. We find the narrowest linewidth of 98 G occurs after a 750 °C anneal.« less

  13. High Throughput Method of Extracting and Counting Strontium-90 in Urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shkrob, I.; Kaminski, M.; Mertz, C.

    2016-03-01

    A method has been developed for the rapid extraction of Sr-90 from the urine of individuals exposed to radiation in a terrorist attack. The method employs two chromatographic ion-exchange materials: Diphonix resin and Sr resin, both of which are commercially available. The Diphonix resin reduces the alkali ion concentrations below 10 mM, and the Sr resin concentrates and decontaminates strontium-90. Experimental and calculational data are given for a variety of test conditions. On the basis of these results, a flowsheet has been developed for the rapid concentration and extraction of Sr-90 from human urine samples for subsequent beta-counting.

  14. Relative biocompatibility of micro-hybrid and nano-hybrid light-activated composite resins.

    PubMed

    Olabisi Arigbede, Abiodun; Folasade Adeyemi, Bukola; Femi-Akinlosotu, Omowumi

    2017-01-01

    Background. In vitro studies have revealed a direct association between resin content and cytotoxicity of composite resins; however, implantation studies in this regard are sparse. This study investigates the relationship between filler content of composite resins and biocompatibility. Methods. This research employed twelve 180‒200-gr male Wistar rats, 1 nano-hybrid (Prime-Dent Inc.) and 1 micro-hybrid (Medental Inc.) composite resins containing 74% and 80‒90% filler content, respectively. The samples were assessed on the 2nd, 14th and 90th day of implantation. Four rats were allocated to each day in this experimental study. A section of 1.5mm long cured nano-hybrid and micro-hybrid materials were implanted into the right and left upper and lower limbs of the rats, respectively. Eight samples were generated on each day of observation. Inflammation was graded according to the criteria suggested by Orstavik and Major. Pearson's chi-squared test was employed to determine the relationship between the tissue responses of the two materials. Statistical significance was set at P < 0.05. Results . The average grade of inflammation for the nano-hybrid on the 2nd day of implantation was 3.3. The micro-hybrid resin had a score of 3.0 for cellular inflammation. On the 14th day, the micro-hybrid resin also exhibited a lower average grade for cellular inflammation. On the 90th day, the micro-hybrid resin had a higher grade of inflammation (0.9) compared to 0.3 recorded for nano-hybrid. The composite resins with higher filler content elicited a significantly lower grade of inflammation irrespective of the duration (χ=20.000, df=8, P=0.010) while the composite resins with lower filler content elicited a significantly lower inflammatory response on the 90th day (χ=4.000, df=1, P=0.046). Conclusion. The composite resins with higher filler content generally elicited significantly lower grades of inflammation, and the composite resins with lower filler content exhibited

  15. Relative biocompatibility of micro-hybrid and nano-hybrid light-activated composite resins

    PubMed Central

    Olabisi Arigbede, Abiodun; Folasade Adeyemi, Bukola; Femi-Akinlosotu, Omowumi

    2017-01-01

    Background. In vitro studies have revealed a direct association between resin content and cytotoxicity of composite resins; however, implantation studies in this regard are sparse. This study investigates the relationship between filler content of composite resins and biocompatibility. Methods. This research employed twelve 180‒200-gr male Wistar rats, 1 nano-hybrid (Prime-Dent Inc.) and 1 micro-hybrid (Medental Inc.) composite resins containing 74% and 80‒90% filler content, respectively. The samples were assessed on the 2nd, 14th and 90th day of implantation. Four rats were allocated to each day in this experimental study. A section of 1.5mm long cured nano-hybrid and micro-hybrid materials were implanted into the right and left upper and lower limbs of the rats, respectively. Eight samples were generated on each day of observation. Inflammation was graded according to the criteria suggested by Orstavik and Major. Pearson’s chi-squared test was employed to determine the relationship between the tissue responses of the two materials. Statistical significance was set at P < 0.05. Results. The average grade of inflammation for the nano-hybrid on the 2nd day of implantation was 3.3. The micro-hybrid resin had a score of 3.0 for cellular inflammation. On the 14th day, the micro-hybrid resin also exhibited a lower average grade for cellular inflammation. On the 90th day, the micro-hybrid resin had a higher grade of inflammation (0.9) compared to 0.3 recorded for nano-hybrid. The composite resins with higher filler content elicited a significantly lower grade of inflammation irrespective of the duration (χ=20.000, df=8, P=0.010) while the composite resins with lower filler content elicited a significantly lower inflammatory response on the 90th day (χ=4.000, df=1, P=0.046). Conclusion. The composite resins with higher filler content generally elicited significantly lower grades of inflammation, and the composite resins with lower filler content exhibited

  16. Biokinetics of yttrium and comparison with its geochemical twin holmium

    DOE PAGES

    Leggett, Rich

    2017-06-01

    The transition metal yttrium (Y, atomic number 39) is chemically similar to elements in the lanthanide family (atomic numbers 57-71, lanthanum through lutetium) and is always present with the lanthanides in rare earth ores. Yttrium and the lanthanide holmium are particularly close chemical and physical analogues and are referred to as geochemical twins because they typically show little fractionation in geological material. Extensive measurements on rocks, soils, and meteorites indicate that the Y/Ho mass concentration ratio rarely falls far from the “chondritic” or “solar system” ratio of ~26. Our paper presents a new biokinetic model for yttrium in adult humansmore » and examines whether yttrium and holmium may be biological as well as geochemical twins. Collected data on yttrium and holmium in plants and human tissues do not allow precise derivations of Y/Ho concentration ratios but with occasional exceptions yield ratios that are reasonably consistent with chondritic values. Predictions of the time-dependent behavior of yttrium in adult humans based on the yttrium model presented here closely approximate predictions of the behavior of holmium based on a previously developed model for holmium. We know that yttrium and holmium are close biological analogues, but the available comparative data are too limited and imprecise to reveal whether there are any significant differences in their biological behavior.« less

  17. Rare earths, the lanthanides, yttrium and scandium

    USGS Publications Warehouse

    Hedrick, J.B.

    2006-01-01

    In 2005, rare earths were not mined in the United States. The major supplier, Molycorp, continued to maintain a large stockpile of rare-earth concentrates and compounds. Consumption decreased of refined rare-earth products. The United States remained a major importer and exporter of rare earths in 2005. During the same period, yttrium was not mined or refined in the US. Hence, supply of yttrium compounds for refined yttrium products came from China, France and Japan. Scandium was not also mined. World production was primarily in China, Russia and Ukraine. Demand for rare earths in 2006 is expected to be closely tied to economic conditions in the US.

  18. Structural phase transitions in yttrium under ultrahigh pressures

    NASA Astrophysics Data System (ADS)

    Samudrala, Gopi K.; Tsoi, Georgiy M.; Vohra, Yogesh K.

    2012-09-01

    X-ray diffraction studies were carried out on the rare earth metal yttrium up to 177 GPa in a diamond anvil cell at room temperature. Yttrium was compressed to 37% of its initial volume at the highest pressure. The rare earth crystal structure sequence hcp → Sm type → dhcp → mixed(dhcp + fcc) → distorted fcc (dfcc) is observed in yttrium below 50 GPa. The dfcc (hR24) phase has been observed to persist in the pressure range of 50-95 GPa. A structural transition from dfcc to a low symmetry phase has been observed in yttrium at 99 ± 4 GPa with a volume change of - 2.6%. This low symmetry phase has been identified as a monoclinic C2/m phase, which has also been observed in other rare earth elements under high pressures. The appearance of this low symmetry monoclinic phase in yttrium shows that its electronic structure under extreme conditions resembles that of heavy rare earth metals, with a significant increase in d-band character of the valence electrons and possibly some f-electron states near the Fermi level.

  19. Structural phase transitions in yttrium under ultrahigh pressures.

    PubMed

    Samudrala, Gopi K; Tsoi, Georgiy M; Vohra, Yogesh K

    2012-09-12

    X-ray diffraction studies were carried out on the rare earth metal yttrium up to 177 GPa in a diamond anvil cell at room temperature. Yttrium was compressed to 37% of its initial volume at the highest pressure. The rare earth crystal structure sequence hcp → Sm type → dhcp → mixed(dhcp + fcc) → distorted fcc (dfcc) is observed in yttrium below 50 GPa. The dfcc (hR24) phase has been observed to persist in the pressure range of 50-95 GPa. A structural transition from dfcc to a low symmetry phase has been observed in yttrium at 99 ± 4 GPa with a volume change of - 2.6%. This low symmetry phase has been identified as a monoclinic C2/m phase, which has also been observed in other rare earth elements under high pressures. The appearance of this low symmetry monoclinic phase in yttrium shows that its electronic structure under extreme conditions resembles that of heavy rare earth metals, with a significant increase in d-band character of the valence electrons and possibly some f-electron states near the Fermi level.

  20. Compliance in 2017 With Federal Calorie Labeling in 90 Chain Restaurants and 10 Retail Food Outlets Prior to Required Implementation.

    PubMed

    Cleveland, Lauren P; Simon, Denise; Block, Jason P

    2018-06-21

    To examine early compliance with the delayed federal calorie labeling regulation that requires posting calories on menus and menu boards at retail food chains with 20 or more establishments nationally. We explored implementation of calorie labeling at 90 of the largest US chain restaurants and the 10 highest-grossing supermarket chains from May to December 2017. We contacted corporate offices and at least 2 locations for each chain, made site visits when possible, and supplemented these efforts with targeted Internet searches. Overall, 71 (79%) restaurant chains partially or fully implemented labeling, as did 9 (90%) supermarket chains. Fast-food and fast-casual restaurants fully implemented labeling at a modestly higher rate than did full-service restaurants. Most of the retail food chains we assessed implemented calorie labeling policies in advance of the May 2018 compliance date. Public Health Implications. Although implementation of federal calorie labeling has been delayed repeatedly in the 8 years since the passage of the legislation, retail food chains have demonstrated a high rate of compliance with calorie labeling in advance of the required May 2018 implementation date. Despite reports from some retail food industries that compliance will be difficult, current implementation shows the feasibility of complying. (Am J Public Health. Published online ahead of print June 21, 2018: e1-e4. doi:10.2105/AJPH.2018.304513).

  1. Technical note: The calibration of {sup 90}Y-labeled SIR-Spheresusing a nondestructive spectroscopic assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selwyn, R.; Micka, J.; DeWerd, L.

    2008-04-15

    {sup 90}Y-labeled SIR-Spheres are currently used to treat patients with hepatic metastases secondary to colorectal adenocarcinoma. In general, the prescribed activity is based on empirical data collected during clinical trials. The activity of the source vial is labeled by the manufacturer as 3.0 GBq{+-}10% and is not independently verified by the end user. This technical note shows that the results of a nondestructive spectroscopic assay of a SIR-Spheressample was 26% higher than the activity stated by the manufacturer. This difference should not impact the current empirical prescription method but may be problematic for patient-specific dosimetry applications, such as image-based dosimetry.

  2. Combined radiochemical procedure for determination of plutonium, americium and strontium-90 in the soil samples from SNTS

    NASA Astrophysics Data System (ADS)

    Kazachevskii, I. V.; Lukashenko, S. N.; Chumikov, G. N.; Chakrova, E. T.; Smirin, L. N.; Solodukhin, V. P.; Khayekber, S.; Berdinova, N. M.; Ryazanova, L. A.; Bannyh, V. I.; Muratova, V. M.

    1999-01-01

    The results of combined radiochemical procedure for the determination of plutonium, americium and90Sr (via measurement of90Y) in the soil samples from SNTS are presented. The processes of co-precipitation of these nuclides with calcium fluoride in the strong acid solutions have been investigated. The conditions for simultaneous separation of americium and yttrium using extraction chromatography have been studied. It follows from analyses of real soil samples that the procedure developed provides the chemical recovery of plutonium and yttrium in the range of 50-95% and 60-95%, respectively. The execution of the procedure requires 3.5 working days including a sample decomposition study.

  3. Radiopacity of Methacrylate and Silorane Composite Resins Using a Digital Radiographic System.

    PubMed

    Firoozmand, Leily Macedo; Cordeiro, Mariana Gonçalves; Da Silva, Marcos André Dos Santos; De Jesus Tavarez, Rudys Rodolfo; Matos Maia Filho, Etevaldo

    The aim of this study was to evaluate the radiopacity of silorane and methacrylate resin composites, comparing them to the enamel, dentin, and aluminum penetrometer using a digital image. From six resin composites (Filtek ™ P90, Filtek Z350, Filtek Z350 XT flow, Tetric Ceram, TPH Spectrum, and SureFil SDR flow) cylindrical disks (5 × 1 mm) were made and radiographed by a digital method, together with a 15-step aluminum step-wedge and a 1 mm slice of human tooth. The degree of radiopacity of each image was quantified using digital image processing. The mean values of the shades of gray of the tested materials were measured and the equivalent width of aluminum was calculated for each resin. The results of our work yielded the following radiopacity values, given here in descending order: Tetric Ceram > TPH > SDR > Z350 > Z350 flow > P90 > enamel > dentin. The radiopacity of the materials was different both for the enamel and for the dentin, except for resin P90, which was no different than enamel. In conclusion, silorane-based resin exhibited a radiopacity higher than dentin and closest to the enamel; a large portion of the methacrylate-based flow and conventional resins demonstrated greater radiopacity in comparison to dentin and enamel.

  4. [Surface characteristics of the acrylic resins according to the polishing methods].

    PubMed

    Vitalariu, Anca Mihaela; Lazăr, Lenuţa; Buruiană, Tinca; Diaconu, Diana; Tatarciuc, Monica Silvia

    2011-01-01

    The objective of this study was to evaluate the effect of the polishing technique and glazing on the porosity of the dental resins. The studied resins were: Castapress/Vertex, Prothyl Hot/Zermack, Rapid Simplified/Vertex, Duracryl Plus/Spofa Dental, Vertex-Soft/Vertex, Superacryl Plus/Spofa Dental. Thirty specimens, five for every resin, of 50/25/2 cm in size were done. One surface of each sample was polished with extrahard tungsten carbide burs, the other surface being polished with extrahard extrafine and diamond burs. The final polishing was done using a conventional method: pumice, water and lathe bristle brush for 90 seconds, 1500 rpm and soft leather polishing wheel for 90 seconds, 3000 rpm. Twenty surfaces were glazed after polishing with Glaze/Bosworth. Vertex Soft specimens were not polished because this is a resilient material. Surface porosity of the acrylic resin specimens was measured by optical microscopy. The lowest porosity was obtained by conventional polishing combined with glazing techniques. No differences between glazed and non/glazed self-curing resin specimens were noticed, but there were differences between self-curing and heat-curing resins. Conventional lathe polishing method is an effective and reliable technique for polishing dental resins. Specimens of self-curing resin had a higher porosity than heat curing resin following the same surface treatment. Higher surface smoothness was obtained by conventional lathe polishing completed by glazing.

  5. Rare earths, the lanthanides, yttrium and scandium

    USGS Publications Warehouse

    Bedinger, G.; Bleiwas, D.

    2012-01-01

    In 2011, rare earths were recovered from bastnasite concentrates at the Mountain Pass Mine in California. Consumption of refined rare-earth products decreased in 2011 from 2010. U.S. rare-earth imports originated primarily from China, with lesser amounts from Austria, Estonia, France and Japan. The United States imported all of its demand for yttrium metal and yttrium compounds, with most of it originating from China. Scandium was imported in various forms and processed domestically.

  6. Treatment of conjunctival lymphomas by beta-ray brachytherapy using a strontium-90-yttrium-90 applicator.

    PubMed

    Regueiro, C A; Valcárcel, F J; Romero, J; de la Torre, A

    2002-12-01

    We reviewed the outcome of the 10 patients (13 eyes) with localized, biopsy-proven, low-grade lymphoma of the conjunctiva treated at our Department between 1988 and 1997. All patients were treated by beta-ray brachytherapy using a bidirectional 90Sr-90Y ophthalmic applicator (Applicator SIA 2, Amersham plc). Total doses, prescribed at the surface of the applicator, varied between 40 Gy and 80 Gy. With a median follow-up of 78 months (range: 14 to 146 months), seven patients remained with no evidence of relapse (67.5% 10 year disease free survival). Local control was achieved in 10 out of 13 eyes (76.9%). Two of the three local relapses were marginal. One of these three patients also developed a metachronous lymphoma in the contralateral conjunctiva. These three patients underwent a second course of brachytherapy with 90Sr/90Y and remained free of second relapse 109, 68 and 33 months after salvage therapy. No cases of systemic relapse were observed. Late (LENT-SOMA) complications were of grade 2 in five eyes, of grade 3 in one eye and of grade 4 in one eye. Late complications of grade 2 or higher were observed in one out of five patients (20%) treated with doses lower or equal to 50 Gy and in six out of eight patients (75%) treated with doses higher than 50 Gy (P=0.086). Our data indicates that beta-ray brachytherapy was ultimately able to control most conjunctival lymphomas but carried a risk of late complications and marginal relapses that was possibly higher than the rates reported for other radiotherapy techniques.

  7. Monoclonal antibody fragment removal mediated by mixed mode resins.

    PubMed

    O'Connor, Ellen; Aspelund, Matthew; Bartnik, Frank; Berge, Mark; Coughlin, Kelly; Kambarami, Mutsa; Spencer, David; Yan, Huiming; Wang, William

    2017-05-26

    Efforts to increase monoclonal antibody expression in cell culture can result in the presence of fragmented species requiring removal in downstream processing. Capto adhere, HEA Hypercel, and PPA Hypercel anion exchange/hydrophobic interaction mixed mode resins were evaluated for their fragment removal capabilities and found to separate large hinge IgG1 antibody fragment (LHF) from monomer. Removal of greater than 75% of LHF population occurred at pH 8 and low conductivity. The mechanism of fragment removal was investigated in two series of experiments. The first experimental series consisted of comparison to chromatographic behavior on corresponding single mode resins. Both single mode anion exchange and hydrophobic interaction resins failed to separate LHF. The second experimental series studied the impact of phase modifiers, ethylene glycol, urea, and arginine on the mixed mode mediated removal. The addition of ethylene glycol decreased LHF removal by half. Further decreases in LHF separation were seen upon incubation with urea and arginine. Therefore, it was discovered that the purification is the result of a mixed mode phenomena dominated by hydrophobic interaction and hydrogen bonding effects. The site of interaction between the LHF and mixed mode resin was determined by chemical labeling of lysine residues with sulfo-NHS acetate. The labeling identified the antibody hinge and light chain regions as mediating the fragment separation. Sequence analysis showed that under separation conditions, a hydrophobic proline patch and hydrogen bonding serine and threonine residues mediate the hinge interaction with the Capto adhere ligand. Additionally, a case study is presented detailing the optimization of fragment removal using Capto adhere resin to achieve purity and yield targets in a manufacturing facility. This study demonstrated that mixed mode resins can be readily integrated into commercial antibody platform processes when additional chromatographic abilities

  8. THE TREATMENT OF CHILDRENS' HEMANGIOMA AND NEVUS FLAMMEUS WITH Sr$sup 90$ AND Y$sup 9$$sup 0$ (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lossl, H.; Jakob, A.

    The authors report the excellent results obtained in the radiotherapy of the hemangioma of the child and of the nevus flammeus by means of strontium-90 and yttrium-90. The method is preferred to others as it reduces the charge of rays on the growing skeleton of the child ami on the gonads. In case of smaller lesions the application of strontium-90 (total dose 3000 to 5000 rep) and surface irradiation by means of yttrium-90 foils (total dose 3000 to 4000 rep) produce good results. The single dose should be around 1OOO rep. The dosage has to be fixed according to themore » erythema which appears with medium intensity. To judge from the gathered experiences the results of this therapy are equivalent to those of radium treatment or Chaoul's close irradiation. (auth)« less

  9. Correlative Imaging of Fluorescent Proteins in Resin-Embedded Plant Material1

    PubMed Central

    Bell, Karen; Mitchell, Steve; Paultre, Danae; Posch, Markus; Oparka, Karl

    2013-01-01

    Fluorescent proteins (FPs) were developed for live-cell imaging and have revolutionized cell biology. However, not all plant tissues are accessible to live imaging using confocal microscopy, necessitating alternative approaches for protein localization. An example is the phloem, a tissue embedded deep within plant organs and sensitive to damage. To facilitate accurate localization of FPs within recalcitrant tissues, we developed a simple method for retaining FPs after resin embedding. This method is based on low-temperature fixation and dehydration, followed by embedding in London Resin White, and avoids the need for cryosections. We show that a palette of FPs can be localized in plant tissues while retaining good structural cell preservation, and that the polymerized block face can be counterstained with cell wall probes. Using this method we have been able to image green fluorescent protein-labeled plasmodesmata to a depth of more than 40 μm beneath the resin surface. Using correlative light and electron microscopy of the phloem, we were able to locate the same FP-labeled sieve elements in semithin and ultrathin sections. Sections were amenable to antibody labeling, and allowed a combination of confocal and superresolution imaging (three-dimensional-structured illumination microscopy) on the same cells. These correlative imaging methods should find several uses in plant cell biology. PMID:23457228

  10. Size-dependent cytotoxicity of yttrium oxide nanoparticles on primary osteoblasts in vitro

    NASA Astrophysics Data System (ADS)

    Zhou, Guoqiang; Li, Yunfei; Ma, Yanyan; Liu, Zhu; Cao, Lili; Wang, Da; Liu, Sudan; Xu, Wenshi; Wang, Wenying

    2016-05-01

    Yttrium oxide nanoparticles are an excellent host material for the rare earth metals and have high luminescence efficiency providing a potential application in photodynamic therapy and biological imaging. In this study, the effects of yttrium oxide nanoparticles with four different sizes were investigated using primary osteoblasts in vitro. The results demonstrated that the cytotoxicity generated by yttrium oxide nanoparticles depended on the particle size, and smaller particles possessed higher toxicological effects. For the purpose to elucidate the relationship between reactive oxygen species generation and cell damage, cytomembrane integrity, intracellular reactive oxygen species level, mitochondrial membrane potential, cell apoptosis rate, and activity of caspase-3 in cells were then measured. Increased reactive oxygen species level was also observed in a size-dependent way. Thus, our data demonstrated that exposure to yttrium oxide nanoparticles resulted in a size-dependent cytotoxicity in cultured primary osteoblasts, and reactive oxygen species generation should be one possible damage pathway for the toxicological effects produced by yttrium oxide particles. The results may provide useful information for more rational applications of yttrium oxide nanoparticles in the future.

  11. Development of 2024 AA-Yttrium composites by Spark Plasma Sintering

    NASA Astrophysics Data System (ADS)

    Vidyasagar, CH S.; Karunakar, D. B.

    2018-04-01

    The method of fabrication of MMNCs is quite a challenge, which includes advanced processing techniques like Spark Plasma Sintering (SPS), etc. The objective of the present work is to fabricate aluminium based MMNCs with the addition of small amounts of yttrium using Spark Plasma Sintering and to evaluate their mechanical and microstructure properties. Samples of 2024 AA with yttrium ranging from 0.1% to 0.5 wt% are fabricated by Spark Plasma Sintering (SPS). Hardness of the samples is determined using Vickers hardness testing machine. The metallurgical characterization of the samples is evaluated by Optical Microscopy (OM), Field Emission Scanning Electron Microscopy (FE-SEM). Unreinforced 2024 AA sample is also fabricated as a benchmark to compare its properties with those of the composite developed. It is found that the yttrium addition increases the above mentioned properties by altering the precipitation kinetics and intermetallic formation to some extent and then decreases gradually when yttrium wt% increases beyond 0.3 wt%. High density (˂ 99.75) is achieved in the samples and highest hardness achieved is 114 Hv, fabricated by spark plasma sintering and uniform distribution of yttrium is observed.

  12. Biocompatibility, Inflammatory Response, and Recannalization Characteristics of Nonradioactive Resin Microspheres: Histological Findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilbao, Jose I., E-mail: Jibilbao@unav.e; Martino, Alba de; Luis, Esther de

    2009-07-15

    Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was to describe the distribution of spheres within the precapillaries, inflammatory response, and recannalization characteristics after embolization with nonradioactive resin microspheres in the kidney and liver. We performed a partial embolization of the liver and kidney vessels in nine white pigs. The left renal and left hepatic arteries were catheterized and filled with nonradioactive resin microspheres. Embolization wasmore » defined as the initiation of near-stasis of blood flow, rather than total occlusion of the vessels. The hepatic circulation was not isolated so that the effects of reflux of microspheres into stomach could be observed. Animals were sacrificed at 48 h, 4 weeks, and 8 weeks, and tissue samples from the kidney, liver, lung, and stomach evaluated. Microscopic evaluation revealed clusters of 10-30 microspheres (15-30 {mu}m in diameter) in the small vessels of the kidney (the arciform arteries, vasa recti, and glomerular afferent vessels) and liver. Aggregates were associated with focal ischemia and mild vascular wall damage. Occlusion of the small vessels was associated with a mild perivascular inflammatory reaction. After filling of the left hepatic artery with microspheres, there was some evidence of arteriovenous shunting into the lungs, and one case of cholecystitis and one case of marked gastritis and ulceration at the site of arterial occlusion due to the presence of clusters of microspheres. Beyond 48 h, microspheres were progressively integrated into the vascular wall by phagocytosis and the lumen recannalized. Eight-week evaluation found that the perivascular inflammatory reaction was mild. Liver cell damage, bile duct

  13. Development of a neutral embedding resin for optical imaging of fluorescently labeled biological tissue

    NASA Astrophysics Data System (ADS)

    Zhou, Hongfu; Gang, Yadong; Chen, Shenghua; Wang, Yu; Xiong, Yumiao; Li, Longhui; Yin, Fangfang; Liu, Yue; Liu, Xiuli; Zeng, Shaoqun

    2017-10-01

    Plastic embedding is widely applied in light microscopy analyses. Previous studies have shown that embedding agents and related techniques can greatly affect the quality of biological tissue embedding and fluorescent imaging. Specifically, it is difficult to preserve endogenous fluorescence using currently available acidic commercial embedding resins and related embedding techniques directly. Here, we developed a neutral embedding resin that improved the green fluorescent protein (GFP), yellow fluorescent protein (YFP), and DsRed fluorescent intensity without adjusting the pH value of monomers or reactivating fluorescence in lye. The embedding resin had a high degree of polymerization, and its fluorescence preservation ratios for GFP, YFP, and DsRed were 126.5%, 155.8%, and 218.4%, respectively.

  14. Response, survival, and long-term toxicity after therapy with the radiolabeled somatostatin analogue [90Y-DOTA]-TOC in metastasized neuroendocrine cancers.

    PubMed

    Imhof, Anna; Brunner, Philippe; Marincek, Nicolas; Briel, Matthias; Schindler, Christian; Rasch, Helmut; Mäcke, Helmut R; Rochlitz, Christoph; Müller-Brand, Jan; Walter, Martin A

    2011-06-10

    To investigate response, survival, and safety profile of the somatostatin-based radiopeptide (90)yttrium-labeled tetraazacyclododecane-tetraacetic acid modified Tyr-octreotide ([(90)Y-DOTA]-TOC) in neuroendocrine cancers. In a clinical phase II single-center open-label trial, patients with neuroendocrine cancers were treated with repeated cycles of [(90)Y-DOTA]-TOC. Each cycle consisted of a single intravenous injection of 3.7GBq/m(2) body-surface [(90)Y-DOTA]-TOC. Additional cycles were withheld in case of tumor progression and/or permanent toxicity. Overall, 1,109 patients received 2,472 cycles of [(90)Y-DOTA]-TOC (median, two; range, one to 10 cycles per patient). Of the 1,109 patients, 378 (34.1%) experienced morphologic response; 172 (15.5%), biochemical response; and 329 (29.7%), clinical response. During a median follow-up of 23 months, 491 patients (44.3%) died. Longer survival was correlated with each: morphologic (hazard ratio [HR], 0.46; 95% CI, 0.38 to 0.56; median survival, 44.7 v 18.3 months; P < .001), biochemical (HR, 0.75; 95% CI, 0.59 to 0.96; 35.3 v 25.7 months; P = .023), and clinical response (HR, 0.68; 95% CI, 0.56 to 0.82; 36.8 v 23.5 months; P < .001). Overall, 142 patients (12.8%) developed grade 3 to 4 transient hematologic toxicities, and 103 patients (9.2%) experienced grade 4 to 5 permanent renal toxicity. Multivariable regression revealed that tumoral uptake in the initial imaging study was predictive for overall survival (HR, 0.45; 95% CI, 0.29 to 0.69; P < .001), whereas the initial kidney uptake was predictive for severe renal toxicity (HR, 1.59; 95% CI, 1.17 to 2.17; P = .003). This study documents the long-term outcome of [(90)Y-DOTA]-TOC treatment in a large cohort. Response to [(90)Y-DOTA]-TOC is associated with longer survival. Somatostatin receptor imaging is predictive for both survival after [(90)Y-DOTA]-TOC treatment and occurrence of renal toxicity.

  15. Microtensile bond strength of composite resin to human enamel prepared using erbium: Yttrium aluminum garnet laser.

    PubMed

    Delfino, Carina Sinclér; Souza-Zaroni, Wanessa Christine; Corona, Silmara Aparecida Milori; Palma-Dibb, Regina Guenka

    2007-02-01

    The Erbium: Yttrium Aluminum Garnet (YAG) laser used for preparation of cavity can alter the substrate and it could influence the bond strength of enamel. The aim of this in vitro study was to evaluate the influence of Er:YAG laser's energy using microtensile bond test. Three groups were obtained (cavity preparation) and each group was divided into two subgroups (adhesive system). After that the adhesive protocol was performed, sections with a cross-sectional area of 0.8 mm2 (+/-0.2 mm2) were obtained. The specimens were mounted in a universal testing machine (0.5 mm/min). Statistical analysis showed a decrease in bond strength for lased groups (p < 0.01) and when the total-etching adhesive system was used the laser 300 mJ subgroup showed higher bond strength compared to the laser 250 mJ (p < 0.01). It was concluded that the cavities prepared using laser appear less receptive to adhesive procedures than conventional bur-cut cavities. Copyright 2006 Wiley Periodicals, Inc.

  16. (90)Y-labelled anti-CD22 epratuzumab tetraxetan in adults with refractory or relapsed CD22-positive B-cell acute lymphoblastic leukaemia: a phase 1 dose-escalation study.

    PubMed

    Chevallier, Patrice; Eugene, Thomas; Robillard, Nelly; Isnard, Françoise; Nicolini, Franck; Escoffre-Barbe, Martine; Huguet, Françoise; Hunault, Mathilde; Marcais, Antoine; Gaschet, Joelle; Cherel, Michel; Guillaume, Thierry; Delaunay, Jacques; Peterlin, Pierre; Eveillard, Marion; Thomas, Xavier; Ifrah, Norbert; Lapusan, Simona; Bodet-Milin, Caroline; Barbet, Jacques; Faivre-Chauvet, Alain; Ferrer, Ludovic; Bene, Marie C; Le Houerou, Claire; Goldenberg, David M; Wegener, William A; Kraeber-Bodéré, Françoise

    2015-03-01

    Prognosis of patients with relapsed or refractory acute lymphoblastic leukaemia is poor and new treatments are needed. We aimed to assess the feasibility, tolerability, dosimetry, and efficacy of yttrium-90-labelled anti-CD22 epratuzumab tetraxetan ((90)Y-DOTA-epratuzumab) radioimmunotherapy in refractory or relapsed CD22-positive B-cell acute lymphoblastic leukaemia in a standard 3 + 3 phase 1 study. Adults (≥18 years) with relapsed or refractory B-cell acute lymphoblastic leukaemia (with CD22 expression on at least 70% of blast cells) were enrolled at six centres in France. Patients received one cycle of (90)Y-DOTA-epratuzumab on days 1 and 8 (give or take 2 days) successively at one of four dose levels: 2·5 mCi/m(2) (92·5 MBq/m(2); level 1), 5·0 mCi/m(2) (185 MBq/m(2); level 2), 7·5 mCi/m(2) (277·5 MBq/m(2); level 3), and 10·0 mCi/m(2) (370 MBq/m(2); level 4). The primary objective was to identify the maximum tolerated dose of (90)Y-DOTA-epratuzumab. We assessed safety during infusions and regularly after radioimmunotherapy over a 6-month period. Analyses included only patients who received radioimmunotherapy. The trial is closed to inclusion and is registered at ClinicalTrials.gov, NCT01354457. Between Aug 25, 2011, and June 11, 2014, 17 patients (median age 62 years; range 27-77) were treated (five at level 1, three at level 2, three at level 3, and six at level 4). Radioimmunotherapy infusion was overall well tolerated. One dose-limiting toxic effect (aplasia lasting 8 weeks) occurred at level 4, but the maximum tolerated dose was not reached. The most common grade 3-4 adverse events were pancytopenia (one patient at level 2, one at level 3, and six at level 4) and infections (three at level 1, one at level 2, and five at level 4). (90)Y-DOTA-epratuzumab radioimmunotherapy is well tolerated. We recommend the dose of 2 × 10·0 mCi/m(2) 1 week apart per cycle for phase 2 studies. Immunomedics and Direction de la Recherche Clinique of Nantes

  17. Formation of Yttrium Oxysulfide Phosphor at Room Temperature

    NASA Astrophysics Data System (ADS)

    Shoji, Masahiko; Sakurai, Kenji

    2005-12-01

    Europium-doped yttrium oxysulfide (Y2O2S:Eu) phosphor was successfully synthesized at room temperature from yttrium oxide, europium oxide, and sulfur. The method employs high-energy ball milling to enable a substitution reaction between oxygen and sulfur, unlike conventional methods, such as heating in a sulfurizing atmosphere. It was found that the material is fluorescent through X-ray irradiation, and the luminescence spectra exhibit four peaks in the wavelength region from 500 to 800 nm.

  18. Analysis of radioactive strontium-90 in food by Čerenkov liquid scintillation counting.

    PubMed

    Pan, Jingjing; Emanuele, Kathryn; Maher, Eileen; Lin, Zhichao; Healey, Stephanie; Regan, Patrick

    2017-08-01

    A simple liquid scintillation counting method using DGA/TRU resins for removal of matrix/radiometric interferences, Čerenkov counting for measuring 90 Y, and EDXRF for quantifying Y recovery was validated for analyzing 90 Sr in various foods. Analysis of samples containing energetic β emitters required using TRU resin to avoid false detection and positive bias. Additional 34% increase in Y recovery was obtained by stirring the resin while eluting Y with H 2 C 2 O 4 . The method showed acceptable accuracy (±10%), precision (10%), and detectability (~0.09Bqkg -1 ). Published by Elsevier Ltd.

  19. METHOD OF SEPARATING RARE EARTHS BY ION EXCHANGE

    DOEpatents

    Spedding, F.H.; Powell, J.E.

    1960-10-18

    A process is given for separating yttrium and rare earth values having atomic numbers of from 57 through 60 and 68 through 71 from an aqueous solution whose pH value can range from 1 to 9. All rare earths and yttrium are first adsorbed on a cation exchange resin, and they are then eluted with a solution of N-hydroxyethylethylenediaminetriacetic acid (HEDTA) in the order of decreasing atomic number, yttrium behaving like element 61; the effluents are collected in fractions. The HEDTA is recovered by elution with ammonia solution and the resin is regenerated with sulfuric acid. Rare earths are precipitated from the various effluents with oxalic acid, and each supernatant is passed over cation exchange resin for adsorption of HEDTA and nonprecipitated rare earths: the oxalic acid is not retained by the resin.

  20. Enhancement of Superconductivity of Lanthanum and Yttrium Sesquicarbide

    DOEpatents

    Krupka, M. C.; Giorgi, A. L.; Krikorian, N. H.; Szklarz, E. G.

    1972-06-22

    A method of enhancing the superconductivity of body-centered cubic lanthanum and yttrium sesquicarbide through formation of the sesquicarbides from ternary alloys of novel composition (N/sub x/M/sub 1-x/)C/sub z/, where N is yttrium or lanthanum, M is thorium, any of the Group IV and VI transition metals, or gold, germanium or silicon, and z is approximately 1.2 to 1.6. These ternary sesquicarbides have superconducting transition temperatures as high as 17.0/sup 0/K.

  1. Enhancement of superconductivity of lanthanum and yttrium sesquicarbide

    DOEpatents

    Krupka, M.C.; Giorgi, A.L.; Krikorian, N.H.; Szklarz, E.G.

    1971-06-22

    A method of enhancing the superconductivity of body-centered cubic lanthanum and yttrium sesquicarbide through formation of the sesquicarbides from ternary alloys of novel composition (N/sub x/M/sub 1-x/)C/sub z/, where N is yttrium or lanthanum, M is thorium, any of the Group IV and VI transition metals, or gold, germanium or silicon, and z is approximately 1.2 to 1.6. These ternary sesquicarbides have superconducting transition temperatures as high as 17.0/sup 0/K.

  2. Synthesis of wrinkled mesoporous silica and its reinforcing effect for dental resin composites.

    PubMed

    Wang, Ruili; Habib, Eric; Zhu, X X

    2017-10-01

    The aim of this work is to explore the reinforcing effect of wrinkled mesoporous silica (WMS), which should allow micromechanical resin matrix/filler interlocking in dental resin composites, and to investigate the effect of silica morphology, loading, and compositions on their mechanical properties. WMS (average diameter of 496nm) was prepared through the self-assembly method and characterized by the use of the electron microscopy, dynamic light scattering, and the N 2 adsorption-desorption measurements. The mechanical properties of resin composites containing silanized WMS and nonporous smaller silica were evaluated with a universal mechanical testing machine. Field-emission scanning electron microscopy was used to study the fracture morphology of dental composites. Resin composites including silanized silica particles (average diameter of 507nm) served as the control group. Higher filler loading of silanized WMS substantially improved the mechanical properties of the neat resin matrix, over the composites loaded with regular silanized silica particles similar in size. The impregnation of smaller secondary silica particles with diameters of 90 and 190nm, denoted respectively as Si90 and Si190, increased the filler loading of the bimodal WMS filler (WMS-Si90 or WMS-Si190) to 60wt%, and the corresponding composites exhibited better mechanical properties than the control fillers made with regular silica particles. Among all composites, the optimal WMS-Si190- filled composite (mass ratio WMS:Si190=10:90, total filler loading 60wt%) exhibited the best mechanical performance including flexural strength, flexural modulus, compressive strength and Vickers microhardness. The incorporation of WMS and its mixed bimodal fillers with smaller silica particles led to the design and formulation of dental resin composites with superior mechanical properties. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. Evaluation of anion exchange resins Tulsion A-30 and Indion-930A by application of radioanalytical technique

    NASA Astrophysics Data System (ADS)

    Singare, P. U.

    2014-07-01

    Radioanalytical technique using 131I and 82Br was employed to evaluate organic based anion exchange resins Tulsion A-30 and Indion-930A. The evaluation was based on performance of these resins during iodide and bromide ion-isotopic exchange reactions. It was observed that for iodide ion-isotopic exchange reaction by using Tulsion A-30 resin, the values of specific reaction rate (min-1), amount of iodide ion exchanged (mmol), initial rate of iodide ion exchange (mmol/min) and log K d were 0.238, 0.477, 0.114, and 11.0, respectively, which was higher than 0.155, 0.360, 0.056, and 7.3, respectively as that obtained by using Indion-930A resins under identical experimental conditions of 40.0°C, 1.000 g of ion exchange resins and 0.003 M labeled iodide ion solution. Also at a constant temperature of 40.0°C, as the concentration of labeled iodide ion solution increases 0.001 to 0.004 M, for Tulsion A-30 resins the percentage of iodide ions exchanged increases from 59.0 to 65.1%, and from 46.4 to 48.8% for Indion-930A resins under identical experimental conditions. The identical trend was observed for both the resins during bromide ion-isotopic exchange reactions. The overall results indicate that under identical experimental conditions, Tulsion A-30 show superior performance over Indion-930A resins. The results of present experimental work have demonstrated that the radioanalytical technique used here can be successfully applied for characterization of different ion exchange resins so as to evaluate their performance under various process parameters.

  4. Production and characterization of europium doped sol-gel yttrium oxide

    NASA Astrophysics Data System (ADS)

    Krebs, J. K.; Hobson, Christopher; Silversmith, Ann

    2004-03-01

    Sol-gel produced materials have recently gained attention for their use in producing nanoscale dielectric materials for confinement studies. Lanthanide impurities in the dielectric enable experimenters to optically probe the structure and dynamic properties of the nanoparticle hosts. We report on an alkoxide sol-gel production method used to produce trivalent europium doped yttrium oxide. Our process follows the standard hydrolysis of an alkoxide precursor with water containing the lanthanide ions. The sol is then aged and calcined at 800 ^oC to produce the powder samples. X-ray diffraction confirms the structure of the powder is that of Y_2O_3. The emission and excitation of the europium impurities is consistent with that of europium doped single crystal yttrium oxide, where it is known that the europium ions substitute for yttrium in the lattice. We therefore conclude that the sol-gel process enables the incorporation of europium ions into the yttrium oxide structure at temperatures far below the melting temperature. The results of preliminary dynamics measurements will also be discussed.

  5. Electronic structure and electron-phonon interaction in hexagonal yttrium by density functional calculations

    NASA Astrophysics Data System (ADS)

    Singh, Prabhakar P.

    2007-03-01

    To understand the pressure-induced changes in the electronic structure and the electron-phonon interaction in yttrium, we have studied hexagonal-close-packed (hcp) yttrium, stable at ambient pressure, and double hexagonal-close-packed (dhcp) yttrium, stable up to around 44GPa , using density-functional-based methods. Our results show that as one goes from hcp yttrium to dhcp yttrium, there are (i) a substantial charge transfer from s→d with extensive modifications of the d band and a sizable reduction in the density of states at the Fermi energy, (ii) a substantial stiffening of phonon modes with the electron-phonon coupling covering the entire frequency range, and (iii) an increase in the electron-phonon coupling constant λ from 0.55 to 1.24, leading to a change in the superconducting transition temperature Tc from 0.3to15.3K for μ*=0.2 .

  6. Alkali metal yttrium neo-pentoxide double alkoxide precursors to alkali metal yttrium oxide nanomaterials

    DOE PAGES

    Boyle, Timothy J.; Neville, Michael L.; Sears, Jeremiah Matthew; ...

    2016-03-15

    In this study, a series of alkali metal yttrium neo-pentoxide ([AY(ONep) 4]) compounds were developed as precursors to alkali yttrium oxide (AYO 2) nanomaterials. The reaction of yttrium amide ([Y(NR 2) 3] where R=Si(CH 3) 3) with four equivalents of H-ONep followed by addition of [A(NR 2)] (A=Li, Na, K) or A o (A o=Rb, Cs) led to the formation of a complex series of A nY(ONep) 3+n species, crystallographically identified as [Y 2Li 3(μ 3-ONep)(μ 3-HONep)(μ-ONep) 5(ONep) 3(HONep) 2] (1), [YNa 2(μ 3-ONep) 4(ONep)] 2 (2), {[Y 2K 3(μ 3-ONep) 3(μ-ONep) 4(ONep) 2(ηξ-tol) 2][Y 4K 2(μ 4-O)(μ 3-ONep) 8(ONep)more » 4]•η x-tol]} (3), [Y 4K 2(μ 4-O)(μ 3-ONep) 8(ONep) 4] (3a), [Y 2Rb 3(μ 4-ONep) 3(μ-ONep) 6] (4), and [Y 2Cs 4(μ 6-O)(μ 3-ONep) 6(μ 3-HONep) 2(ONep) 2(η x-tol) 4]•tol (5). Compounds 1–5 were investigated as single source precursors to AYOx nanomaterials following solvothermal routes (pyridine, 185 °C for 24h). The final products after thermal processing were found by powder X-ray diffraction experiments to be Y 2O 3 with variable sized particles based on transmission electron diffraction. Energy dispersive X-ray spectroscopy studies indicated that the heavier alkali metal species were present in the isolated nanomaterials.« less

  7. Evidence of yttrium silicate inclusions in YSZ-porcelain veneers.

    PubMed

    Stoner, Brian R; Griggs, Jason A; Neidigh, John; Piascik, Jeffrey R

    2014-04-01

    This report introduces the discovery of crystalline defects that can form in the porcelain veneering layer when in contact with yttria-stabilized zirconia (YSZ). The focus was on dental prostheses and understanding the defects that form in the YSZ/porcelain system; however the data reported herein may have broader implications toward the use and stability of YSZ-based ceramics in general. Specimens were cut from fully sintered YSZ plates and veneering porcelain was applied (<1 mm thick) to one surface and fired under manufacturer's recommended protocol. Scanning electron microscopy (SEM) with integrated electron dispersive X-ray (EDAX) was used for microstructural and elemental analysis. EDAX, for chemical analysis and transmission electron diffraction (TED) for structural analysis were both performed in the transmission electron microscope (TEM). Additionally, in order to spatially resolve Y-rich precipitates, micro-CT scans were conducted at varying depths within the porcelain veneer. Local EDAX (SEM) was performed in the regions of visible inclusions and showed significant increases in yttrium concentration. TEM specimens also showed apparent inclusions in the porcelain and selected area electron diffraction was performed on these regions and found the inclusions to be crystalline and identified as either yttrium-silicate (Y2 SiO5 ) or yttrium-disilicate (Y2 Si2 O7 ). Micro-CT data showed that yttrium-silicate precipitates were distributed throughout the thickness of the porcelain veneer. Future studies are needed to determine whether many of the premature failures associated with this materials system may be the result of crystalline flaws that form as a result of high temperature yttrium diffusion near the surfaces of YSZ. © 2013 Wiley Periodicals, Inc.

  8. Oligosilylarylnitrile: The Thermoresistant Thermosetting Resin with High Comprehensive Properties.

    PubMed

    Wang, Mingcun; Ning, Yi

    2018-04-11

    One of the highest thermoresistant thermosetting resins ever studied so far, oligosilylarylnitrile resin, was investigated first in this study. Oligosilylarylnitrile was synthesized by lithium-reduced Wurtz-Fittig condensation reaction, and the prepared viscous resin exhibited moderate rheological behaviors while heated purely or together with 20% polysilazane as a cross-linking agent. The thermal curing temperatures were found by differential scanning calorimetry at 268 °C (pure) and 158 °C (with the polysilazane cross-linking agent), which is comparably close to that of polysilylarylacetylene resin (normally at 220-250 °C) but much lower than those of polyimide and phthalonitrile resins (normally >300 °C), indicating the admirable material processability of oligosilylnitrile. The cured oligosilylarylnitrile resins have extremely high thermal resistance, indicated by the results of thermogravimetric analysis (the mass residue at 800 °C is >90% under N 2 ) and dynamic mechanical analysis (the glass-transition temperature is >420 °C). The mechanical property of the oligosilylarylnitrile-matrixed silica-cloth reinforced laminate is comparably close to those of polyimide and phthalonitrile but much higher than that of polysilylarylacetylene, indicating the enviable thermal and mechanical properties of oligosilylnitrile. Thus, among the high-temperature resins ever studied so far, the oligosilylarylnitrile resin was found to have the almost best comprehensive characteristics of processability and properties.

  9. Resin composite repair: Quantitative microleakage evaluation of resin-resin and resin-tooth interfaces with different surface treatments

    PubMed Central

    Celik, Cigdem; Cehreli, Sevi Burcak; Arhun, Neslihan

    2015-01-01

    Objective: The aim was to evaluate the effect of different adhesive systems and surface treatments on the integrity of resin-resin and resin-tooth interfaces after partial removal of preexisting resin composites using quantitative image analysis for microleakage testing protocol. Materials and Methods: A total of 80 human molar teeth were restored with either of the resin composites (Filtek Z250/GrandioSO) occlusally. The teeth were thermocycled (1000×). Mesial and distal 1/3 parts of the restorations were removed out leaving only middle part. One side of the cavity was finished with course diamond bur and the other was air-abraded with 50 μm Al2O3. They were randomly divided into four groups (n = 10) to receive: Group 1: Adper Single Bond 2; Group 2: All Bond 3; Group 3: ClearfilSE; Group 4: BeautiBond, before being repaired with the same resin composite (Filtek Z250). The specimens were re-thermocycled (1000×), sealed with nail varnish, stained with 0.5% basic fuchsin, sectioned mesiodistally and photographed digitally. The extent of dye penetration was measured by image analysis software (ImageJ) for both bur-finished and air-abraded surfaces at resin-tooth and resin-resin interfaces. The data were analyzed statistically. Results: BeautiBond exhibited the most microleakage at every site. Irrespective of adhesive and initial composite type, air-abrasion showed less microleakage except for BeautiBond. The type of initial repaired restorative material did not affect the microleakage. BeautiBond adhesive may not be preferred in resin composite repair in terms of microleakage prevention. Conclusions: Surface treatment with air-abrasion produced the lowest microleakage scores, independent of the adhesive systems and the pre-existing resin composite type. Pre-existing composite type does not affect the microleakage issue. All-in-one adhesive resin (BeautiBond) may not be preferred in resin composite repair in terms of microleakage prevention. PMID:25713491

  10. Effects of Different Surface Treatment Methods and MDP Monomer on Resin Cementation of Zirconia Ceramics an In Vitro Study

    PubMed Central

    Tanış, Merve Çakırbay; Akçaboy, Cihan

    2015-01-01

    Introduction: Resin cements are generally preferred for cementation of zirconia ceramics. Resin bonding of zirconia ceramics cannot be done with the same methods of traditional ceramics because zirconia is a silica-free material. In recent years, many methods have been reported in the literature to provide the resin bonding of zirconia ceramics. The purpose of this in vitro study is to evaluate effects of different surface treatments and 10-metacryloxydecyl dihydrogen phosphate (MDP) monomer on shear bond strength between zirconia and resin cement. Methods: 120 zirconia specimens were treated as follows: Group I: sandblasting, group II: sandblasting + tribochemical silica coating + silane, group III: sandblasting + Nd:YAG (neodymium: yttrium-aluminum-garnet) laser. One specimen from each group was evaluated under scanning electron microscope (SEM). Specimens in each group were bonded either with conventional resin cement Variolink II or with a MDP containing resin cement Panavia F2.0. Subgroups of bonded specimens were stored in distilled water (37°C) for 24 hours or 14 days. Following water storage shear bond strength test was performed at a crosshead speed of 1 mm/min in a universal test machine. Then statistical analyses were performed. Results: Highest shear bond strength values were observed in group II. No significant difference between group I and III was found when Panavia F2.0 resin cement was used. When Variolink II resin cement was used group III showed significantly higher bond strength than group I. In group I, Panavia F2.0 resin cement showed statistically higher shear bond strength than Variolink II resin cement. In group II no significant difference was found between resin cements. No significant difference was found between specimens stored in 37°C distilled water for 24 hours and 14 days. In group I surface irregularities with sharp edges and grooves were observed. In group II less roughened surface was observed with silica particles. In group

  11. Effects of Different Surface Treatment Methods and MDP Monomer on Resin Cementation of Zirconia Ceramics an In Vitro Study.

    PubMed

    Tanış, Merve Çakırbay; Akçaboy, Cihan

    2015-01-01

    Resin cements are generally preferred for cementation of zirconia ceramics. Resin bonding of zirconia ceramics cannot be done with the same methods of traditional ceramics because zirconia is a silica-free material. In recent years, many methods have been reported in the literature to provide the resin bonding of zirconia ceramics. The purpose of this in vitro study is to evaluate effects of different surface treatments and 10-metacryloxydecyl dihydrogen phosphate (MDP) monomer on shear bond strength between zirconia and resin cement. 120 zirconia specimens were treated as follows: Group I: sandblasting, group II: sandblasting + tribochemical silica coating + silane, group III: sandblasting + Nd:YAG (neodymium: yttrium-aluminum-garnet) laser. One specimen from each group was evaluated under scanning electron microscope (SEM). Specimens in each group were bonded either with conventional resin cement Variolink II or with a MDP containing resin cement Panavia F2.0. Subgroups of bonded specimens were stored in distilled water (37°C) for 24 hours or 14 days. Following water storage shear bond strength test was performed at a crosshead speed of 1 mm/min in a universal test machine. Then statistical analyses were performed. Highest shear bond strength values were observed in group II. No significant difference between group I and III was found when Panavia F2.0 resin cement was used. When Variolink II resin cement was used group III showed significantly higher bond strength than group I. In group I, Panavia F2.0 resin cement showed statistically higher shear bond strength than Variolink II resin cement. In group II no significant difference was found between resin cements. No significant difference was found between specimens stored in 37°C distilled water for 24 hours and 14 days. In group I surface irregularities with sharp edges and grooves were observed. In group II less roughened surface was observed with silica particles. In group III surface microcracks

  12. Electric, Magnetic, and Magnetoelectric Properties of Yttrium-Containing BaY0.025Ti0.9625O3-SrFe12O19 Composite

    NASA Astrophysics Data System (ADS)

    Rather, Mehraj ud Din; Samad, Rubiya; Want, Basharat

    2018-03-01

    The physical properties of BaY0.025Ti0.9625O3, SrFe12O19, and 0.90BaY0.025Ti0.9625O3-0.10 SrFe12O19 composite have been studied. The proposed composite was synthesized by solid-state reaction method from yttrium barium titanate processed by solid-state reaction and strontium hexaferrite obtained by a sol-gel process. Microstructural analysis revealed monophasic grains for yttrium barium titanate phase, while loosely packed biphasic structure was observed for the composite. Powder x-ray analysis showed that the individual phases retained their crystal structure in the composite, without formation of any new additional phase. Measurement of magnetic hysteresis loops at room temperature indicated that the magnetic parameters of the composite were diluted by the presence of the ferroelectric phase. The ferroelectric hysteresis of yttrium barium titanate confirmed the ferroelectric transition at 119°C. Meanwhile, the symmetrical ferroelectric loops observed at different fields established the ferroelectric nature of the composite. Improved dielectric properties and low dielectric losses were observed due to yttrium doping in the composite. The diffuseness of the ferroelectric transitions for the composite was confirmed by the Curie-Weiss law. Activation energy calculations revealed the charge-hopping conduction mechanism in the composite. Magnetodielectric studies confirmed that the overall magnetocapacitance in the composite exhibited combined effects of magnetoresistance and magnetoelectric coupling.

  13. The prognostic value of functional and anatomical parameters for the selection of patients receiving yttrium-90 microspheres for the treatment of liver cancer

    NASA Astrophysics Data System (ADS)

    Mesoloras, Geraldine

    Yttrium-90 (90Y) microsphere therapy is being utilized as a treatment option for patients with primary and metastatic liver cancer due to its ability to target tumors within the liver. The success of this treatment is dependent on many factors, including the extent and type of disease and the nature of prior treatments received. Metabolic activity, as determined by PET imaging, may correlate with the number of viable cancer cells and reflect changes in viable cancer cell volume. However, contouring of PET images by hand is labor intensive and introduces an element of irreproducibility into the determination of functional target/tumor volume (FTV). A computer-assisted method to aid in the automatic contouring of FTV has the potential to substantially improve treatment individualization and outcome assessment. Commercial software to determine FTV in FDG-avid primary and metastatic liver tumors has been evaluated and optimized. Volumes determined using the automated technique were compared to those from manually drawn contours identified using the same cutoff in the standard uptake value (SUV). The reproducibility of FTV is improved through the introduction of an optimal threshold value determined from phantom experiments. Application of the optimal threshold value from the phantom experiments to patient scans was in good agreement with hand-drawn determinations of the FTV. It is concluded that computer-assisted contouring of the FTV for primary and metastatic liver tumors improves reproducibility and increases accuracy, especially when combined with the selection of an optimal SUV threshold determined from phantom experiments. A method to link the pre-treatment assessment of functional (PET based) and anatomical (CT based) parameters to post-treatment survival and time to progression was evaluated in 22 patients with colorectal cancer liver metastases treated using 90Y microspheres and chemotherapy. The values for pre-treatment parameters that were the best

  14. Marginal integrity of low-shrinkage and methacrylate-based composite resins: Effect of three different hemostatic agents

    PubMed Central

    Khoroushi, Maryam; Sahraneshin-Samani, Mahsa

    2016-01-01

    Background Moisture control is very important in restorative procedures in dentistry. Use of hemostatic agents helps control moisture; however, they might result in changes on enamel and dentin surfaces, affecting composite resin bond quality. The aim of this in vitro study was to evaluate the marginal microleakage of two different composite resins with the use of three different hemostatic agents. Material and Methods Standardized Class V cavities were prepared on the buccal and lingual surfaces of 48 premolars with cervical margins 1 mm apical to the cementoenamel junction (CEJ). The samples were randomly divided into 8 groups. In groups 1 to 4, an etch-and-rinse adhesive (Adper Single Bond) was applied as the bonding system, followed by exposure to different hemostatic agent: group 1: no hemostatic agent (control); group 2: ViscoStat; group 3: ViscoStat Clear; and group 4: trichloracetic acid, as hemostatic agents. The cavities were restored with Z-250 composite resin. In group 5 to 8 Silorane System Adhesive (Filtek P90 Adhesive) was applied as a bonding agent, followed by exposure to different hemostatic agents in a manner similar to that in groups 1to 4. The cavities were restored with Filtek P90, a low-shrinkage composite resin. The samples in each group were evaluated for dye penetration under a stereomicroscope at ×36 after 24 hours and a 500-round thermocycling procedure at enamel and dentin margins. Statistical analysis was carried out using Kruskal-Wallis and Mann-Whitney tests (α=0.05). Results Z-250 composite resin exhibited significantly higher dentin microleakage scores compared to Filtek P90 (P = 0.004). Trichloracetic acid increased dentin microleakage with Filtek P90 (P=0.033). Conclusions Under the limitations of this in vitro study, application of hemostatic agents did not affect microleakage of the two tested composite resins except for trichloracetic acid that increased marginal microleakage when used with Filtek P90. Key words

  15. Yttrium and rare earth stabilized fast reactor metal fuel

    DOEpatents

    Guon, Jerold; Grantham, LeRoy F.; Specht, Eugene R.

    1992-01-01

    To increase the operating temperature of a reactor, the melting point and mechanical properties of the fuel must be increased. For an actinide-rich fuel, yttrium, lanthanum and/or rare earth elements can be added, as stabilizers, to uranium and plutonium and/or a mixture of other actinides to raise the melting point of the fuel and improve its mechanical properties. Since only about 1% of the actinide fuel may be yttrium, lanthanum, or a rare earth element, the neutron penalty is low, the reactor core size can be reduced, the fuel can be burned efficiently, reprocessing requirements are reduced, and the nuclear waste disposal volumes reduced. A further advantage occurs when yttrium, lanthanum, and/or other rare earth elements are exposed to radiation in a reactor, they produce only short half life radioisotopes, which reduce nuclear waste disposal problems through much shorter assured-isolation requirements.

  16. Optimized anion exchange column isolation of zirconium-89 (89Zr) from yttrium cyclotron target: Method development and implementation on an automated fluidic platform.

    PubMed

    O'Hara, Matthew J; Murray, Nathaniel J; Carter, Jennifer C; Morrison, Samuel S

    2018-04-13

    Zirconium-89 ( 89 Zr), produced by the (p, n) reaction from naturally monoisotopic yttrium ( nat Y), is a promising positron emitting isotope for immunoPET imaging. Its long half-life of 78.4 h is sufficient for evaluating slow physiological processes. A prototype automated fluidic system, coupled to on-line and in-line detectors, has been constructed to facilitate development of new 89 Zr purification methodologies. The highly reproducible reagent delivery platform and near-real time monitoring of column effluents allows for efficient method optimization. The separation of Zr from dissolved Y metal targets was evaluated using several anion exchange resins. Each resin was evaluated against its ability to quantitatively capture Zr from a load solution high in dissolved Y. The most appropriate anion exchange resin for this application was identified, and the separation method was optimized. The method is capable of a high Y decontamination factor (>10 5 ) and has been shown to remove Fe, an abundant contaminant in Y foils, from the 89 Zr elution fraction. Finally, the method was evaluated using cyclotron bombarded Y foil targets; the method was shown to achieve >95% recovery of the 89 Zr present in the foils. The anion exchange column method described here is intended to be the first 89 Zr isolation stage in a dual-column purification process. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Optimized anion exchange column isolation of zirconium-89 ( 89Zr) from yttrium cyclotron target: Method development and implementation on an automated fluidic platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O’Hara, Matthew J.; Murray, Nathaniel J.; Carter, Jennifer C.

    Zirconium-89 ( 89Zr), produced by the (p, n) reaction from naturally monoisotopic yttrium ( natY), is a promising positron emitting isotope for immunoPET imaging. Its long half-life of 78.4 h is sufficient for evaluating slow physiological processes. A prototype automated fluidic system, coupled to on-line and in-line detectors, has been constructed to facilitate development of new 89Zr purification methodologies. The highly reproducible reagent delivery platform and near-real time monitoring of column effluents allows for efficient method optimization. The separation of Zr from dissolved Y metal targets was evaluated using several anion exchange resins. Each resin was evaluated against its abilitymore » to quantitatively capture Zr from a load solution high in dissolved Y. The most appropriate anion exchange resin for this application was identified, and the separation method was optimized. The method is capable of a high Y decontamination factor (>10 5) and has been shown to remove Fe, an abundant contaminant in Y foils, from the 89Zr elution fraction. Finally, the method was evaluated using cyclotron bombarded Y foil targets; the method was shown to achieve >95% recovery of the 89Zr present in the foils. The anion exchange column method described here is intended to be the first 89Zr isolation stage in a dual-column purification process.« less

  18. Optimized anion exchange column isolation of zirconium-89 ( 89Zr) from yttrium cyclotron target: Method development and implementation on an automated fluidic platform

    DOE PAGES

    O’Hara, Matthew J.; Murray, Nathaniel J.; Carter, Jennifer C.; ...

    2018-02-24

    Zirconium-89 ( 89Zr), produced by the (p, n) reaction from naturally monoisotopic yttrium ( natY), is a promising positron emitting isotope for immunoPET imaging. Its long half-life of 78.4 h is sufficient for evaluating slow physiological processes. A prototype automated fluidic system, coupled to on-line and in-line detectors, has been constructed to facilitate development of new 89Zr purification methodologies. The highly reproducible reagent delivery platform and near-real time monitoring of column effluents allows for efficient method optimization. The separation of Zr from dissolved Y metal targets was evaluated using several anion exchange resins. Each resin was evaluated against its abilitymore » to quantitatively capture Zr from a load solution high in dissolved Y. The most appropriate anion exchange resin for this application was identified, and the separation method was optimized. The method is capable of a high Y decontamination factor (>10 5) and has been shown to remove Fe, an abundant contaminant in Y foils, from the 89Zr elution fraction. Finally, the method was evaluated using cyclotron bombarded Y foil targets; the method was shown to achieve >95% recovery of the 89Zr present in the foils. The anion exchange column method described here is intended to be the first 89Zr isolation stage in a dual-column purification process.« less

  19. Denture labeling: A new approach

    PubMed Central

    Bansal, Pardeep K.; Sharma, Akshey; Bhanot, Rajesh

    2011-01-01

    The need for denture labeling is important for forensic and social reasons in case patients need to be identified individually. The importance of denture marking has long been acknowledged by the dental profession. Over the years, various denture marking systems have been reported in the literature, but none till date fulfills all the prescribed ADA specifications. A simple, easy, inexpensive procedure for marking accurate identification marks on dentures with a lead foil is described here. The label caring the patient information is incorporated in the acrylic resin during the denture processing. PMID:21957379

  20. Can simultaneous contact allergies to phenyl glycidyl ether and epoxy resins of the bisphenol A/F-types be explained by contamination of the epoxy resins?

    PubMed

    Pontén, Ann; Zimerson, Erik; Bruze, Magnus

    2008-11-01

    Simultaneous contact allergies to epoxy resins based on diglycidyl ether of bisphenol A (DGEBA-R) or epoxy resins of the bisphenol F-type and the reactive diluent phenyl glycidyl ether (PGE) have been reported. The reason might be cross-reactivity, exposure to an epoxy resin system with PGE as a component, or contamination by PGE in the epoxy resin. To study contamination by PGE, 20 commercial epoxy resins were analysed for the presence of PGE. To study contact allergy to PGE and its relation to epoxy resins by inserting PGE in the standard series. Among 2227 patients, 7 reacted to PGE. Of 23 (30%) patients, 7 with contact allergy to DGEBA-R and 7/19 (37%) with contact allergy to an epoxy resin of the bisphenol F-type reacted to PGE. All 7 patients with contact allergy to PGE reacted both to the DGEBA-R and to the epoxy resin of the bisphenol F-type. PGE was found in 90% of the investigated resins. The amounts of PGE ranged between 0.004% w/w and 0.18% w/w. Most probably, the presence of PGE as a contaminant in epoxy resins is of minor importance for the sensitization, but possibly the contamination of PGE might elicit contact dermatitis in individuals with a high reactivity to PGE.

  1. Recovery of yttrium from fluorescent powder of cathode ray tube, CRT: Zn removal by sulphide precipitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Innocenzi, Valentina, E-mail: valentina.innocenzi1@univaq.it; De Michelis, Ida; Ferella, Francesco

    2013-11-15

    Highlights: • Treatment of fluorescent powder of CRT waste. • Factorial experimental designs to study acid leaching of fluorescent powder and the purification of leach liquors. • Recover of yttrium by precipitation using oxalic acid. • Suitable flowsheet to recover yttrium from fluorescent powder. - Abstract: This work is focused on the recovery of yttrium and zinc from fluorescent powder of cathode ray tube (CRT). Metals are extracted by sulphuric acid in the presence of hydrogen peroxide. Leaching tests are carried out according to a 2{sup 2} full factorial plan and the highest extraction yields for yttrium and zinc equalmore » to 100% are observed under the following conditions: 3 M of sulphuric acid, 10% v/v of H{sub 2}O{sub 2} concentrated solution at 30% v/v, 10% w/w pulp density, 70 °C and 3 h of reaction. Two series of precipitation tests for zinc are carried out: a 2{sup 2} full factorial design and a completely randomized factorial design. In these series the factors investigated are pH of solution during the precipitation and the amount of sodium sulphide added to precipitate zinc sulphide. The data of these tests are used to describe two empirical mathematical models for zinc and yttrium precipitation yields by regression analysis. The highest precipitation yields for zinc are obtained under the following conditions: pH equal to 2–2.5% and 10–12% v/v of Na{sub 2}S concentrated solution at 10% w/v. In these conditions the coprecipitation of yttrium is of 15–20%. Finally further yttrium precipitation experiments by oxalic acid on the residual solutions, after removing of zinc, show that yttrium could be recovered and calcined to obtain the final product as yttrium oxide. The achieved results allow to propose a CRT recycling process based on leaching of fluorescent powder from cathode ray tube and recovery of yttrium oxide after removing of zinc by precipitation. The final recovery of yttrium is 75–80%.« less

  2. The effect of processing on autohesive strength development in thermoplastic resins and composites

    NASA Technical Reports Server (NTRS)

    Howes, Jeremy C.; Loos, Alfred C.; Hinkley, Jeffrey A.

    1989-01-01

    In the present investigation of processing effects on the autohesive bond strength of neat polysulfone resin and graphite-reinforced polysulfone-matrix composites measured resin bond strength development in precracked compact tension specimens 'healed' by heating over a contact period at a given temperature. The critical strain energy release rate of refractured composite specimens did not exhibit the strong time or temperature dependence of the neat resin tests; only 80-90 percent of the undamaged fracture energy is recoverable.

  3. Neutron scattering study of yttrium iron garnet

    NASA Astrophysics Data System (ADS)

    Shamoto, Shin-ichi; Ito, Takashi U.; Onishi, Hiroaki; Yamauchi, Hiroki; Inamura, Yasuhiro; Matsuura, Masato; Akatsu, Mitsuhiro; Kodama, Katsuaki; Nakao, Akiko; Moyoshi, Taketo; Munakata, Koji; Ohhara, Takashi; Nakamura, Mitsutaka; Ohira-Kawamura, Seiko; Nemoto, Yuichi; Shibata, Kaoru

    2018-02-01

    The nuclear and magnetic structure and full magnon dispersions of yttrium iron garnet Y3Fe5O12 have been studied using neutron scattering. The refined nuclear structure is distorted to a trigonal space group of R 3 ¯ . The highest-energy dispersion extends up to 86 meV. The observed dispersions are reproduced by a simple model with three nearest-neighbor-exchange integrals between 16 a (octahedral) and 24 d (tetrahedral) sites, Ja a, Ja d, and Jd d, which are estimated to be 0.00 ±0.05 , -2.90 ±0.07 , and -0.35 ±0.08 meV, respectively. The lowest-energy dispersion below 14 meV exhibits a quadratic dispersion as expected from ferromagnetic magnons. The imaginary part of q -integrated dynamical spin susceptibility χ″(E ) exhibits a square-root energy dependence at low energies. The magnon density of state is estimated from χ″(E ) obtained on an absolute scale. The value is consistent with the single chirality mode for the magnon branch expected theoretically.

  4. Experimental Analysis of Critical Current and Alternating Current Losses of High-Temperature Superconductor Tape with Resin and Gallium-Indium-Tin

    PubMed Central

    Sun, Yajie; Zhang, Huiming; Meng, Yuanzhu

    2018-01-01

    This paper experimentally analyzes the critical current degradation and AC (alternating current) losses of second-generation (2G) high-temperature superconductor (HTS) tape during the impregnation process. Two impregnation materials were utilized: Gallium-Indium-Tin (GaInSn), and an epoxy resin, Araldite. The critical current of the impregnation materials was measured after different thermal cycles and compared with the tape with no impregnation process. The experimental results show that the critical current of Yttrium Barium Copper Oxide (YBCO) short samples varies between differently impregnated materials. The resin, Araldite, degraded the critical current; however, the GaInSn showed no degradation. Two degradation patterns with Araldite were identified due to the impregnation process, and the corresponding causes were analyzed. We further measured the AC losses of tapes impregnated with liquid metal at different frequencies, up to 600 Hz. Based on the experimental results, GaInSn liquid metal should be the most suitable impregnation material in terms of critical current degradation. PMID:29642490

  5. Experimental Analysis of Critical Current and Alternating Current Losses of High-Temperature Superconductor Tape with Resin and Gallium-Indium-Tin.

    PubMed

    Yu, Dongmin; Sun, Yajie; Zhang, Huiming; Meng, Yuanzhu; Liu, Huanan

    2018-04-08

    This paper experimentally analyzes the critical current degradation and AC (alternating current) losses of second-generation (2G) high-temperature superconductor (HTS) tape during the impregnation process. Two impregnation materials were utilized: Gallium-Indium-Tin (GaInSn), and an epoxy resin, Araldite. The critical current of the impregnation materials was measured after different thermal cycles and compared with the tape with no impregnation process. The experimental results show that the critical current of Yttrium Barium Copper Oxide (YBCO) short samples varies between differently impregnated materials. The resin, Araldite, degraded the critical current; however, the GaInSn showed no degradation. Two degradation patterns with Araldite were identified due to the impregnation process, and the corresponding causes were analyzed. We further measured the AC losses of tapes impregnated with liquid metal at different frequencies, up to 600 Hz. Based on the experimental results, GaInSn liquid metal should be the most suitable impregnation material in terms of critical current degradation.

  6. Repair Strength in Simulated Restorations of Methacrylate- or Silorane-Based Composite Resins.

    PubMed

    Consani, Rafael Leonardo Xediek; Marinho, Tatiane; Bacchi, Atais; Caldas, Ricardo Armini; Feitosa, Victor Pinheiro; Pfeifer, Carmem Silvia

    2016-01-01

    The study verified the bond strength in simulated dental restorations of silorane- or methacrylate-based composites repaired with methacrylate-based composite. Methacrylate- (P60) or silorane-based (P90) composites were used associated with adhesive (Adper Single Bond 2). Twenty-four hemi-hourglass-shaped samples were repaired with each composite (n=12). Samples were divided according to groups: G1= P60 + Adper Single Bond 2+ P60; G2= P60 + Adper Single Bond 2 + P60 + thermocycling; G3= P90 + Adper Single Bond 2 + P60; and G4= P90 + Adper Single Bond 2 + P60 + thermocycling. G1 and G3 were submitted to tensile test 24 h after repair procedure, and G2 and G4 after submitted to 5,000 thermocycles at 5 and 55 ?#61616;C for 30 s in each bath. Tensile bond strength test was accomplished in an universal testing machine at crosshead speed of 0.5 mm/min. Data (MPa) were analyzed by two-way ANOVA and Tukey's test (5%). Sample failure pattern (adhesive, cohesive in resin or mixed) was evaluated by stereomicroscope at 30?#61655; and images were obtained in SEM. Bond strength values of methacrylate-based composite samples repaired with methacrylate-based composite (G1 and G2) were greater than for silorane-based samples (G3 and G4). Thermocycling decreased the bond strength values for both composites. All groups showed predominance of adhesive failures and no cohesive failure in composite resin was observed. In conclusion, higher bond strength values were observed in methacrylate-based resin samples and greater percentage of adhesive failures in silorane-based resin samples, both composites repaired with methacrylate-based resin.

  7. Recovery of yttrium from cathode ray tubes and lamps’ fluorescent powders: experimental results and economic simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Innocenzi, V., E-mail: valentina.innocenzi1@univaq.it; De Michelis, I.; Ferella, F.

    2013-11-15

    Highlights: • Fluorescent powder of lamps. • Fluorescent powder of cathode ray rubes. • Recovery of yttrium from fluorescent powders. • Economic simulation for the processes to recover yttrium from WEEE. - Abstract: In this paper, yttrium recovery from fluorescent powder of lamps and cathode ray tubes (CRTs) is described. The process for treating these materials includes the following: (a) acid leaching, (b) purification of the leach liquors using sodium hydroxide and sodium sulfide, (c) precipitation of yttrium using oxalic acid, and (d) calcinations of oxalates for production of yttrium oxides. Experimental results have shown that process conditions necessary tomore » purify the solutions and recover yttrium strongly depend on composition of the leach liquor, in other words, whether the powder comes from treatment of CRTs or lamp. In the optimal experimental conditions, the recoveries of yttrium oxide are about 95%, 55%, and 65% for CRT, lamps, and CRT/lamp mixture (called MIX) powders, respectively. The lower yields obtained during treatments of MIX and lamp powders are probably due to the co-precipitation of yttrium together with other metals contained in the lamps powder only. Yttrium loss can be reduced to minimum changing the experimental conditions with respect to the case of the CRT process. In any case, the purity of final products from CRT, lamps, and MIX is greater than 95%. Moreover, the possibility to treat simultaneously both CRT and lamp powders is very important and interesting from an industrial point of view since it could be possible to run a single plant treating fluorescent powder coming from two different electronic wastes.« less

  8. Results and adverse events of personalized peptide receptor radionuclide therapy with 90Yttrium and 177Lutetium in 1048 patients with neuroendocrine neoplasms.

    PubMed

    Baum, Richard P; Kulkarni, Harshad R; Singh, Aviral; Kaemmerer, Daniel; Mueller, Dirk; Prasad, Vikas; Hommann, Merten; Robiller, Franz C; Niepsch, Karin; Franz, Holger; Jochems, Arthur; Lambin, Philippe; Hörsch, Dieter

    2018-03-30

    Peptide receptor radionuclide therapy (PRRT) of patients with somatostatin receptor expressing neuroendocrine neoplasms has shown promising results in clinical trials and a recently published phase III study. In our center, 2294 patients were screened between 2004 and 2014 by 68 Ga somatostatin receptor (SSTR) PET/CT. Intention to treat analysis included 1048 patients, who received at least one cycle of 90 Yttrium or 177 Lutetium-based PRRT. Progression free survival was determined by 68 Ga SSTR-PET/CT and EORTC response criteria. Adverse events were determined by CTCAE criteria. Overall survival (95% confidence interval) of all patients was 51 months (47.0-54.9) and differed significantly according to radionuclide, grading, previous therapies, primary site and functionality. Progression free survival (based on PET/CT) of all patients was 19 months (16.9-21), which was significantly influenced by radionuclide, grading, and origin of neuroendocrine neoplasm. Progression free survival after initial progression and first and second resumption of PRRT after therapy-free intervals of more than 6 months were 11 months (9.4-12.5) and 8 months (6.4-9.5), respectively. Myelodysplastic syndrome or leukemia developed in 22 patients (2.1%) and 5 patients required hemodialysis after treatment, other adverse events were rare. PRRT is effective and overall survival is favorable in patients with neuroendocrine neoplasms depending on the radionuclide used for therapy, grading and origin of the neuroendocrine neoplasm which is not exactly mirrored in progression free survival as determined by highly sensitive 68 Ga somatostatin receptor PET/CT using EORTC criteria for determining response to therapy.

  9. An artificial test substrate for evaluating electron microscopic immunocytochemical labeling reactions.

    PubMed

    Gagne, G D; Miller, M F

    1987-08-01

    We describe an artificial substrate system for optimization of labeling parameters in electron microscope immunocytochemical studies. The system involves use of blocks of glutaraldehyde-polymerized BSA into which a desired antigen is incorporated by a simple soaking procedure. The resulting antigen-impregnated artificial substrate can then be fixed and embedded identically to a piece of tissue. The BSA substrate can also be dried and then sectioned for immunolabeling with or without chemical fixation and without exposing the antigen to dehydrating agents and embedding resins. The effects of various fixation and embedding procedures can thus be evaluated separately. Other parameters affecting immunocytochemical labeling, such as antibody and conjugate concentration, can also be evaluated. We used this system, along with immunogold labeling, to determine quantitatively the optimal fixation and embedding conditions for labeling of hepatitis B surface antigen (HbsAg), human IgG, and horseradish peroxidase. Using unfixed and unembedded HBsAg, we were able to detect antigen concentrations below 20 micrograms/ml. We have shown that it is not possible to label HBsAg within resin-embedded cells using conventional aldehyde fixation protocols and polyclonal antibodies.

  10. In situ hybridization and immunofluorescence on resin-embedded tissue to identify the components of Nissl substance.

    PubMed

    Singhrao, Sim K; Nair-Roberts, Radha G

    2010-05-01

    It is not clear whether the Nissl substance is present at the axon hillock. To clarify this gap in knowledge, we conducted in situ hybridization (ISH) on mouse brain tissue using 30-microm cryostat and 1-3-microm acrylic resin sections. Cryostat and rehydrated resin sections were exposed to digoxygenin-labeled glutamic acid decarboxylase 1 sense and antisense riboprobes. Consecutive sections from tissue embedded in resin were subjected to the ribosomal protein L26 primary antibody to determine the distribution of the ribo/polysomes. ISH results from the antisense riboprobe in both cryostat and resin-embedded tissue sections demonstrated an abundance of message in the neurons from the substantia nigra pars reticulate. In addition, the resin sections demonstrated hybridization signal in the axon hillock of some neurons. Immunofluorescence labeling of consecutive sections using an antibody to the most abundant ribosomal protein L26 confirmed their distribution in the cell body and the axon hillock of similar neurons. Compared with the 30-microm cryostat sections, the most striking feature of ISH in the thinner resin (2-3 microm) sections was that there was a phenomenal improvement in the overall clarity and spatial resolution. Reexamination of the axon hillock when continuous with the cell body in cryostat sections revealed that the same message was also present, except it was overlooked initially because of overlapping cell populations in thick tissue slices. As ribosomes are a component of Nissl substance, we propose that the axon hillock, like other parts of the neuron, does contain Nissl substance. (c) 2009 Wiley-Liss, Inc.

  11. Effect of sulfuric acid etching of polyetheretherketone on the shear bond strength to resin cements.

    PubMed

    Sproesser, Oliver; Schmidlin, Patrick R; Uhrenbacher, Julia; Roos, Malgorzata; Gernet, Wolfgang; Stawarczyk, Bogna

    2014-10-01

    To examine the influence of etching duration on the bond strength of PEEK substrate in combination with different resin composite cements. In total, 448 PEEK specimens were fabricated, etched with sulfuric acid for 5, 15, 30, 60, 90, 120, and 300 s and then luted with two conventional resin cements (RelyX ARC and Variolink II) and one self-adhesive resin cement (Clearfil SA Cement) (n = 18/subgroup). Non-etched specimens served as the control group. Specimens were stored in distilled water for 28 days at 37°C and shear bond strengths were measured. Data were analyzed nonparametrically using Kruskal-Wallis-H (p < 0.05). Non-etched PEEK demonstrated no bond strength to resin composite cements. The optimal etching duration varied with the type of resin composite: 60 s for RelyX ARC (15.3 ± 7.2 MPa), 90 s for Variolink II (15.2 ± 7.2 MPa), and 120 s for Clearfil SA Cement (6.4 ± 5.9 MPa). Regardless of etching duration, however, the self-etching resin composite cement showed significantly lower shear bond strength values when compared to groups luted with the conventional resin composites. Although sulfuric acid seems to be suitable and effective for PEEK surface pre-treatment, further investigations are required to examine the effect of other adhesive systems and cements.

  12. Effect of humic acid on ciprofloxacin removal by magnetic multifunctional resins

    PubMed Central

    Wang, Wei; Cheng, Jiade; Jin, Jing; Zhou, Qing; Ma, Yan; Zhao, Qingqing; Li, Aimin

    2016-01-01

    Background organic matter significantly influences the removal of emerging contaminants in natural water. In this work, the adsorption of ciprofloxacin (CPX) onto a series of magnetic multifunctional resins (GMA10-GMA90) in the presence and absence of humic acid (HA) was conducted to demonstrate the effect of HA. Both hydrophobic and ion exchange interactions contributed to CPX adsorption. Negative charge-assisted hydrogen bonds also participated in the adsorption process, resulting in the high adsorption amount of anionic CPX onto the negatively charged GMA30 under basic solutions. HA could impact CPX adsorption not only as a competitive adsorbate but also as an additional adsorbent. At pH 5.6, the additional adsorption sites provided by adsorbed HA molecules on the resins dominated and thus facilitated the adsorption process. While at pH 10, HA inhibited the adsorption of CPX by directly competing for ion exchange sites and coexisting with CPX in the solution. The ratio of the amount of CPX adsorbed by dissolved HA to that by the resin reached as high as 1.61 for GMA90. The adsorbed HA molecules onto the resins could provide additional adsorption sites for CPX as proven by the enhanced CPX adsorption in HA-preloading systems at pH 5.6. PMID:27464502

  13. Effect of humic acid on ciprofloxacin removal by magnetic multifunctional resins

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Cheng, Jiade; Jin, Jing; Zhou, Qing; Ma, Yan; Zhao, Qingqing; Li, Aimin

    2016-07-01

    Background organic matter significantly influences the removal of emerging contaminants in natural water. In this work, the adsorption of ciprofloxacin (CPX) onto a series of magnetic multifunctional resins (GMA10-GMA90) in the presence and absence of humic acid (HA) was conducted to demonstrate the effect of HA. Both hydrophobic and ion exchange interactions contributed to CPX adsorption. Negative charge-assisted hydrogen bonds also participated in the adsorption process, resulting in the high adsorption amount of anionic CPX onto the negatively charged GMA30 under basic solutions. HA could impact CPX adsorption not only as a competitive adsorbate but also as an additional adsorbent. At pH 5.6, the additional adsorption sites provided by adsorbed HA molecules on the resins dominated and thus facilitated the adsorption process. While at pH 10, HA inhibited the adsorption of CPX by directly competing for ion exchange sites and coexisting with CPX in the solution. The ratio of the amount of CPX adsorbed by dissolved HA to that by the resin reached as high as 1.61 for GMA90. The adsorbed HA molecules onto the resins could provide additional adsorption sites for CPX as proven by the enhanced CPX adsorption in HA-preloading systems at pH 5.6.

  14. Synthesis and properties of hydroxy acrylic resin with high solid content

    NASA Astrophysics Data System (ADS)

    Yu, Zhen; Hu, Mingguang; Cui, Han; Xiao, Jijun

    2017-10-01

    Manufacturers of automotive repair finishes are tending to reduce more and more the level of volatile organic compounds in their paints in order to comply with increasingly strict environmental legislation. A high solid hydroxy acrylic resin was synthesised using CARDURA E10 and a type of hydroxyacrylic acid resin, its' acid value, hydroxylvalue, viscosity, structure, morphology was measured and film-forming properties after curing were characterised. The results show that the addition of CARDURA E10 in the copolymer composition significantly reduced the viscosity of the polymer system, improved the solid content of the resin and the physical properties of the coating. The hydroxyl acrylate resin with solid content of 90% and excellent comprehensive performance were successfully prepared by controlling the initiator dosage, polymerization temperature and monomer ratio.

  15. Neutron Activated Samarium-153 Microparticles for Transarterial Radioembolization of Liver Tumour with Post-Procedure Imaging Capabilities

    PubMed Central

    Hashikin, Nurul Ab. Aziz; Yeong, Chai-Hong; Abdullah, Basri Johan Jeet; Ng, Kwan-Hoong; Chung, Lip-Yong; Dahalan, Rehir; Perkins, Alan Christopher

    2015-01-01

    Introduction Samarium-153 (153Sm) styrene divinylbenzene microparticles were developed as a surrogate for Yttrium-90 (90Y) microspheres in liver radioembolization therapy. Unlike the pure beta emitter 90Y, 153Sm possess both therapeutic beta and diagnostic gamma radiations, making it possible for post-procedure imaging following therapy. Methods The microparticles were prepared using commercially available cation exchange resin, Amberlite IR-120 H+ (620–830 μm), which were reduced to 20–40 μm via ball mill grinding and sieve separation. The microparticles were labelled with 152Sm via ion exchange process with 152SmCl3, prior to neutron activation to produce radioactive 153Sm through 152Sm(n,γ)153Sm reaction. Therapeutic activity of 3 GBq was referred based on the recommended activity used in 90Y-microspheres therapy. The samples were irradiated in 1.494 x 1012 n.cm-2.s-1 neutron flux for 6 h to achieve the nominal activity of 3.1 GBq.g-1. Physicochemical characterisation of the microparticles, gamma spectrometry, and in vitro radiolabelling studies were carried out to study the performance and stability of the microparticles. Results Fourier Transform Infrared (FTIR) spectroscopy of the Amberlite IR-120 resins showed unaffected functional groups, following size reduction of the beads. However, as shown by the electron microscope, the microparticles were irregular in shape. The radioactivity achieved after 6 h neutron activation was 3.104 ± 0.029 GBq. The specific activity per microparticle was 53.855 ± 0.503 Bq. Gamma spectrometry and elemental analysis showed no radioactive impurities in the samples. Radiolabelling efficiencies of 153Sm-Amberlite in distilled water and blood plasma over 48 h were excellent and higher than 95%. Conclusion The laboratory work revealed that the 153Sm-Amberlite microparticles demonstrated superior characteristics for potential use in hepatic radioembolization. PMID:26382059

  16. Selective liquid chromatographic separation of yttrium from heavier rare earth elements using acetic acid as a novel eluent.

    PubMed

    Kifle, Dejene; Wibetoe, Grethe

    2013-09-13

    One of the major difficulties in the rare earth elements separation is purification of yttrium from heavy rare earth elements. Thus, an HPLC method using acetic acid as novel eluent was explored for selective separation of yttrium form the heavy rare earth elements. When acetic acid is used as a mobile phase yttrium eluted with the lighter lanthanides. This is contrary to its relative position amongst heavier lanthanides when eluents commonly used for separation of rare earth elements were employed. The shift in elution position of yttrium with acetic acid as eluent may reflect a relatively lower stability constant of the yttrium-AcOH complex (in the same order as for the lighter lanthanides) compared to the corresponding AcOH complexes with heavy lanthanides, enabling selective separation of yttrium from the latter. The method was successfully used for selective separation of yttrium in mixed rare earth sample containing about 80% of yttrium and about 20% of heavy rare earth oxides. Thus, the use of AcOH as eluent is an effective approach for separating and determining the trace amounts of heavy rare earth elements in large amounts of yttrium matrix. Separation was performed on C18 column by running appropriate elution programs. The effluent from the column was monitored with diode array detector at absorbance wavelength of 658nm after post column derivatization with Arsenazo III. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Surface flashover performance of epoxy resin microcomposites improved by electron beam irradiation

    NASA Astrophysics Data System (ADS)

    Huang, Yin; Min, Daomin; Li, Shengtao; Li, Zhen; Xie, Dongri; Wang, Xuan; Lin, Shengjun

    2017-06-01

    The influencing mechanism of electron beam irradiation on surface flashover of epoxy resin/Al2O3 microcomposite was investigated. Epoxy resin/Al2O3 microcomposite samples with a diameter of 50 mm and a thickness of 1 mm were prepared. The samples were irradiated by electron beam with energies of 10 and 20 keV and a beam current of 5 μA for 5 min. Surface potential decay, surface conduction, and surface flashover properties of untreated and irradiated samples were measured. Both the decay rate of surface potential and surface conductivity decrease with an increase in the energy of electron beam. Meanwhile, surface flashover voltage increase. It was found that both the untreated and irradiated samples have two trap centers, which are labeled as shallow and deep traps. The increase in the energy and density of deep surface traps enhance the ability to capture primary emitted electrons. In addition, the decrease in surface conductivity blocks electron emission at the cathode triple junction. Therefore, electron avalanche at the interface between gas and an insulating material would be suppressed, eventually improving surface flashover voltage of epoxy resin microcomposites.

  18. Holmium: yttrium aluminum garnet laser-assisted endoscopic sinus surgery: laboratory experience.

    PubMed

    Shapshay, S M; Rebeiz, E E; Bohigian, R K; Hybels, R L; Aretz, H T; Pankratov, M M

    1991-02-01

    Endoscopic sinus surgery has gained wide acceptance since its introduction into the United States. Complex sinus anatomy and troublesome bleeding have been associated with complications, which vary in severity from synechia to blindness and leakage of cerebrospinal fluid. Endoscopic sinus surgery using a holmium: yttrium aluminum garnet pulsed solid-state laser oscillating at 2.1 microns with fiberoptic delivery was performed in the laboratory, and the results were compared with those of conventional endoscopic sinus surgery. Three beagle dogs, six human cadaver heads, and one calf head were used in the in vivo and in vitro studies to evaluate the bone ablation, tissue coagulation, and hemostatic properties of the holmium: yttrium aluminum garnet laser. Modified endoscopic telescopes for sinus surgery, a newly developed handpiece for fiberoptic delivery, and other surgical instruments were used. The results indicate that the holmium: yttrium aluminum garnet laser and new delivery instrumentation provide good hemostasis and controlled soft-tissue ablation and bone removal. The access to all sinuses in the human cadaver model was very good. The canine in vivo study showed delayed but complete healing on the laser-treated side. Clinical evaluation of the holmium: yttrium aluminum garnet laser is warranted to increase the precision and safety of endoscopic sinus surgery.

  19. Monte carlo simulations of Yttrium reaction rates in Quinta uranium target

    NASA Astrophysics Data System (ADS)

    Suchopár, M.; Wagner, V.; Svoboda, O.; Vrzalová, J.; Chudoba, P.; Tichý, P.; Kugler, A.; Adam, J.; Závorka, L.; Baldin, A.; Furman, W.; Kadykov, M.; Khushvaktov, J.; Solnyshkin, A.; Tsoupko-Sitnikov, V.; Tyutyunnikov, S.; Bielewicz, M.; Kilim, S.; Strugalska-Gola, E.; Szuta, M.

    2017-03-01

    The international collaboration Energy and Transmutation of Radioactive Waste (E&T RAW) performed intensive studies of several simple accelerator-driven system (ADS) setups consisting of lead, uranium and graphite which were irradiated by relativistic proton and deuteron beams in the past years at the Joint Institute for Nuclear Research (JINR) in Dubna, Russia. The most recent setup called Quinta, consisting of natural uranium target-blanket and lead shielding, was irradiated by deuteron beams in the energy range between 1 and 8 GeV in three accelerator runs at JINR Nuclotron in 2011 and 2012 with yttrium samples among others inserted inside the setup to measure the neutron flux in various places. Suitable activation detectors serve as one of possible tools for monitoring of proton and deuteron beams and for measurements of neutron field distribution in ADS studies. Yttrium is one of such suitable materials for monitoring of high energy neutrons. Various threshold reactions can be observed in yttrium samples. The yields of isotopes produced in the samples were determined using the activation method. Monte Carlo simulations of the reaction rates leading to production of different isotopes were performed in the MCNPX transport code and compared with the experimental results obtained from the yttrium samples.

  20. Resin impregnation process for producing a resin-fiber composite

    NASA Technical Reports Server (NTRS)

    Palmer, Raymond J. (Inventor); Moore, William E. (Inventor)

    1994-01-01

    Process for vacuum impregnation of a dry fiber reinforcement with a curable resin to produce a resin-fiber composite, by drawing a vacuum to permit flow of curable liquid resin into and through a fiber reinforcement to impregnate same and curing the resin-impregnated fiber reinforcement at a sufficient temperature and pressure to effect final curing. Both vacuum and positive pressure, e.g. autoclave pressure, are applied to the dry fiber reinforcement prior to application of heat and prior to any resin flow to compact the dry fiber reinforcement, and produce a resin-fiber composite of reduced weight, thickness and resin content, and improved mechanical properties. Preferably both a vacuum and positive pressure, e.g. autoclave pressure, are also applied during final curing.

  1. Comparison of resin film infusion, resin transfer molding, and consolidation of textile preforms for primary aircraft structure

    NASA Technical Reports Server (NTRS)

    Suarez, J.; Dastin, S.

    1992-01-01

    Innovative design concepts and cost effective fabrication processes were developed for damage tolerant primary structures that can perform at a design ultimate strain level of 6000 micro inch/inch. Attention focused on the use of textile high performance fiber reinforcement concepts that provide improved damage tolerance and out-of-plane load capability, low cost resin film infusion (RFI) and resin transfer molding (RTM) processes, and thermoplastic forming concepts. The fabrication of wing 'Y' spars by four different materials and/or processes methods is described: fabricated using IM7 angle interlock 0 to 90 deg woven preforms with + or - 45 deg plies stitched with Toray high strength graphite thread and processed using RFI and 3501-6 epoxy; fabricated using G40-800 knitted/stitched preforms and processed using RFI and 3501-6 epoxy; fabricated using G40-800 knitted/stitched preforms using RTM and Tactix 123/H41 epoxy; and fabricated preforms using AS4(6K)/PEEK 150 g commingled angle interlock 0 to 90 deg woven preforms with + or - 45 deg commingled plies stitched using high strength graphite thread and processed by consolidation. Structural efficiency, processability, and acquisition cost are compared.

  2. Results and adverse events of personalized peptide receptor radionuclide therapy with 90Yttrium and 177Lutetium in 1048 patients with neuroendocrine neoplasms

    PubMed Central

    Baum, Richard P.; Kulkarni, Harshad R.; Singh, Aviral; Kaemmerer, Daniel; Mueller, Dirk; Prasad, Vikas; Hommann, Merten; Robiller, Franz C.; Niepsch, Karin; Franz, Holger; Jochems, Arthur; Lambin, Philippe; Hörsch, Dieter

    2018-01-01

    Introduction Peptide receptor radionuclide therapy (PRRT) of patients with somatostatin receptor expressing neuroendocrine neoplasms has shown promising results in clinical trials and a recently published phase III study. Methods In our center, 2294 patients were screened between 2004 and 2014 by 68Ga somatostatin receptor (SSTR) PET/CT. Intention to treat analysis included 1048 patients, who received at least one cycle of 90Yttrium or 177Lutetium-based PRRT. Progression free survival was determined by 68Ga SSTR-PET/CT and EORTC response criteria. Adverse events were determined by CTCAE criteria. Results Overall survival (95% confidence interval) of all patients was 51 months (47.0-54.9) and differed significantly according to radionuclide, grading, previous therapies, primary site and functionality. Progression free survival (based on PET/CT) of all patients was 19 months (16.9-21), which was significantly influenced by radionuclide, grading, and origin of neuroendocrine neoplasm. Progression free survival after initial progression and first and second resumption of PRRT after therapy-free intervals of more than 6 months were 11 months (9.4-12.5) and 8 months (6.4-9.5), respectively. Myelodysplastic syndrome or leukemia developed in 22 patients (2.1%) and 5 patients required hemodialysis after treatment, other adverse events were rare. Conclusion PRRT is effective and overall survival is favorable in patients with neuroendocrine neoplasms depending on the radionuclide used for therapy, grading and origin of the neuroendocrine neoplasm which is not exactly mirrored in progression free survival as determined by highly sensitive 68Ga somatostatin receptor PET/CT using EORTC criteria for determining response to therapy. PMID:29682195

  3. Synthesis of aluminum-based scandium-yttrium master alloys

    NASA Astrophysics Data System (ADS)

    Bazhin, V. Yu.; Kosov, Ya. I.; Lobacheva, O. L.; Dzhevaga, N. V.

    2015-07-01

    The preparation technology for an Al-2% Sc-0.5% Y master alloy using aluminum-manganese alloys has been developed and tested. The microstructure of the prepared master alloy is studied and the compositions of intermetallics is determined. The efficient technological parameters of the synthesis are determined. It is shown that varying the compositions of starting reagents and alloying additions and optimizing the process conditions (temperature, mixing, etc.) allow us to forecast the manufacturing and operating characteristics of aluminum-based master alloys. Joint additions of scandium and yttrium oxides to a charge favor a substantial decrease in the grain size of the formed intermetallics; this effect appears to the utmost in the case of microallying with yttrium up to 0.5 wt %.

  4. Factors affecting marginal integrity of class II bulk-fill composite resin restorations

    PubMed Central

    Savadi Oskoee, Siavash; Bahari, Mahmoud; Jafari Navimipour, Elmira; Ajami, Amir Ahmad; Ghiasvand, Negar; Savadi Oskoee, Ayda

    2017-01-01

    Background. Bulk-fill composite resins are a new type of resin-based composite resins, claimed to have the capacity to be placed in thick layers, up to 4 mm. This study was carried out to evaluate factors affecting gap formation in Cl II cavities restored using the bulk-fill technique. Methods. A total of 60 third molars were used in this study. Two Cl II cavities were prepared in each tooth, one on the mesial aspect 1 mm coronal to the CEJ and one on the distal aspect 1 mm apical to the CEJ. The teeth were divided into 4 groups: A: The cavities were restored using the bulk-fill technique with Filtek P90 composite resin and its adhesive system and light-cured with quartz tungsten halogen (QTH) light-curing unit. B: The cavities were restored similar to that in group A but light-cured with an LED light-curing unit. C: The cavities were restored using the bulk-fill technique with X-tra Fil composite resin and Clearfil SE Bond adhesive system and light-cured with a QTH curing unit. D: The cavities were restored similar to that in group C but light-cured with an LED light-curing unit. The gaps were examined under a stereomicroscope at ×60. Data were analyzed with General Linear Model test. In cases of statistical significance (P<0.05), post hoc Bonferroni test was used for further analyses. Results. The light-curing unit type had no effect on gap formation. However, the results were significant in relation to the composite resin type and margin location (P<0.001). The cumulative effects of light-curing unit*gingival margin and light-curing unit*composite resin type were not significant; however, the cumulative effect of composite rein type*gingival margin was significant (P=0.04) Conclusion. X-tra Fil composite exhibited smaller gaps compared with Filtek P90 composite with both light-curing units. Both composite resins exhibited smaller gaps at enamel margins. PMID:28748051

  5. The influence of erbium:yttrium-aluminum-garnet laser ablation with variable pulse width on morphology and microleakage of composite restorations.

    PubMed

    Navarro, Ricardo Scarparo; Gouw-Soares, Sheila; Cassoni, Alessandra; Haypek, Patricia; Zezell, Denise Maria; de Paula Eduardo, Carlos

    2010-11-01

    The objective of this study was to evaluate the influence of various pulse widths with different energy parameters of erbium:yttrium-aluminum-garnet (Er:YAG) laser (2.94 mum) on the morphology and microleakage of cavities restored with composite resin. Identically sized class V cavities were prepared on the buccal surfaces of 54 bovine teeth by high-speed drill (n = 6, control, group 1) and prepared by Er:YAG laser (Fidelis 320A, Fotona, Slovenia) with irradiation parameters of 350 mJ/ 4 Hz or 400 mJ/2 Hz and pulse width: group 2, very short pulse (VSP); group 3, short pulse (SP); group 4, long pulse (LP); group 5, very long pulse (VLP). All cavities were filled with composite resin (Z-250-3 M), stored at 37 degrees C in distilled water, polished after 24 h, and thermally stressed (700 cycles/5-55 degrees C). The teeth were impermeabilized, immersed in 50% silver nitrate solution for 8 h, sectioned longitudinally, and exposed to Photoflood light for 10 min to reveal the stain. The leakage was evaluated under stereomicroscope by three different examiners, in a double-blind fashion, and scored (0-3). The results were analyzed by Kruskal-Wallis test (P > 0.05) and showed that there was no significant differences between the groups tested. Under scanning electron microscopy (SEM) the morphology of the cavities prepared by laser showed irregular enamel margins and dentin internal walls, and a more conservative pattern than that of conventional cavities. The different power settings and pulse widths of Er:YAG laser in cavity preparation had no influence on microleakage of composite resin restorations.

  6. 50 CFR 216.90 - Purposes.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Dolphin Safe Tuna Labeling § 216.90 Purposes. This subpart governs the requirements for using the official..., to label tuna or tuna products offered for sale in or exported from the United States using the term dolphin-safe or suggesting the tuna were harvested in a manner not injurious to dolphins. [69 FR 55307...

  7. 50 CFR 216.90 - Purposes.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Dolphin Safe Tuna Labeling § 216.90 Purposes. This subpart governs the requirements for using the official..., to label tuna or tuna products offered for sale in or exported from the United States using the term dolphin-safe or suggesting the tuna were harvested in a manner not injurious to dolphins. [69 FR 55307...

  8. 50 CFR 216.90 - Purposes.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Dolphin Safe Tuna Labeling § 216.90 Purposes. This subpart governs the requirements for using the official..., to label tuna or tuna products offered for sale in or exported from the United States using the term dolphin-safe or suggesting the tuna were harvested in a manner not injurious to dolphins. [69 FR 55307...

  9. 50 CFR 216.90 - Purposes.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Dolphin Safe Tuna Labeling § 216.90 Purposes. This subpart governs the requirements for using the official..., to label tuna or tuna products offered for sale in or exported from the United States using the term dolphin-safe or suggesting the tuna were harvested in a manner not injurious to dolphins. [69 FR 55307...

  10. 50 CFR 216.90 - Purposes.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Dolphin Safe Tuna Labeling § 216.90 Purposes. This subpart governs the requirements for using the official..., to label tuna or tuna products offered for sale in or exported from the United States using the term dolphin-safe or suggesting the tuna were harvested in a manner not injurious to dolphins. [69 FR 55307...

  11. Assessment of microleakage of class V restored by resin composite and resin-modified glass ionomer and pit and fissure resin-based sealants following Er:YAG laser conditioning and acid etching: in vitro study

    PubMed Central

    Luong, Emilie; Shayegan, Amir

    2018-01-01

    Aim The aim of this study was to make a comparison between microleakage of conventionally restored class V cavities using acid etchant and the ones conditioned by erbium-doped yttrium aluminum garnet (Er:YAG) laser, and also to assess and compare the effectiveness of enamel surface treatments of occlusal pits and fissures by acid etching and conditioned by Er:YAG laser-etch. Materials and methods Seventy-two extracted third molars were used in this study. The samples were divided into two major groups: class V cavities and pit and fissure sealants. Each subgroup was divided into conventional acid etching, Er:YAG laser conditioning and conventional acid etching, and combination with Er:YAG laser conditioning (n=12). The teeth were placed in 2% methylene blue dye solution, were sectioned, and were evaluated according to the dye penetration criteria. Two samples per subgroup were chosen for scanning electron microscopic (SEM) analysis. Results There was a significant difference between occlusal and cervical margin groups. Laser conventional composite cementum group showed more microleakage values compared to other groups. There was no significant difference between occlusal margin groups. However, there was a significant difference between cervical margin groups in terms of microleakage. In sealant groups, there was a significant difference between laser and conventional with/without laser treatment groups in terms of microleakage. Conclusion Based on the results reported in this study, it can be concluded that the application of the Er:YAG laser beneath the resin composite, the resin-modified glass ionomers (GIs), and the fissure sealant placement may be an alternative enamel and dentin etching method to acid etching. PMID:29881311

  12. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins

    PubMed Central

    da SILVA, Paulo Maurício Batista; ACOSTA, Emílio José Tabaré Rodríguez; JACOBINA, Matheus; PINTO, Luciana de Rezende; PORTO, Vinícius Carvalho

    2011-01-01

    Objective Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. Material and Methods Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%. Results There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. Conclusions Repeated immersion cycles in disinfecting solutions alter ∆E* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye. PMID:22230997

  13. Temperature Rise during Primer, Adhesive, and Composite Resin Photopolymerization of a Low-Shrinkage Composite Resin under Caries-Like Dentin Lesions

    PubMed Central

    Mousavinasab, Sayed-Mostafa; Khoroushi, Maryam; Moharreri, Mohammadreza

    2012-01-01

    Objective. This study evaluated temperature rise of low-shrinkage (LS) self-etch primer (P), LS self-etch adhesive (A), and P90 silorane-based composite resin systems, photopolymerized under normal and artificially demineralized dentin. Methods. Forty 1.5 mm-thick dentin discs were prepared from sound human molars, half of which were demineralized. Temperature rise was measured during photopolymerization using a K-type thermocouple under the discs: 10 s and 40 s irradiation of the discs (controls/groups 1 and 2); 10 s irradiation of primer (P), 10 s irradiation of adhesive (A), 40 s irradiation of P90 without P and A, and 40 s irradiation of P90 with P and A (groups 3 to 6, resp.). The samples were photopolymerized using an LED unit under 550 mW/cm2 light intensity. Data was analyzed using repeated measures ANOVA and paired-sample t-test (α = 0.05). Results. There were no significant differences in temperature rise means between the two dentin samples for each irradiation duration (P > 0.0001), with significant differences between the two irradiation durations (P > 0.0001). Temperature rise measured with 40 s irradiation was significantly higher than that of 10 s duration for undemineralized and demineralized dentin P < 0.0001). Conclusions. Light polymerization of P90 low-shrinkage composite resin resulted in temperature rise approaching threshold value under artificially demineralized and undemineralized dentin. PMID:23320185

  14. Sol-Gel Synthesis and Antioxidant Properties of Yttrium Oxide Nanocrystallites Incorporating P-123.

    PubMed

    Mellado-Vázquez, Rebeca; García-Hernández, Margarita; López-Marure, Arturo; López-Camacho, Perla Yolanda; de Jesús Morales-Ramírez, Ángel; Beltrán-Conde, Hiram Isaac

    2014-09-19

    Yttrium oxide (Y₂O₃) nanocrystallites were synthesized by mean of a sol-gel method using two different precursors. Raw materials used were yttrium nitrate and yttrium chloride, in methanol. In order to promote oxygen vacancies, P-123 poloxamer was incorporated. Synthesized systems were heat-treated at temperatures from 700 °C to 900 °C. Systems at 900 °C were prepared in the presence and absence of P-123 using different molar ratios (P-123:Y = 1:1 and 2:1). Fourier transform infrared spectroscopy (FTIR) results revealed a characteristic absorption band of Y-O vibrations typical of Y₂O₃ matrix. The structural phase was analyzed by X-ray diffraction (XRD), showing the characteristic cubic phase in all systems. The diffraction peak that presented the major intensity corresponded to the sample prepared from yttrium chloride incorporating P-123 in a molar ratio of P-123:Y = 2:1 at 900 °C. Crystallites sizes were determined by Scherrer equation as between 21 nm and 32 nm. Antioxidant properties were estimated by 2,2-diphenyl-1-picrylhydrazyl (DPPH•) assays; the results are discussed.

  15. Comparative efficacy of 177Lu and 90Y for Anti-CD20 Pretargeted Radioimmunotherapy in Murine Lymphoma Xenograft Models

    DOE PAGES

    Frost, Sofia H. L.; Frayo, Shani L.; Miller, Brian W.; ...

    2015-03-18

    Purpose Pretargeted radioimmunotherapy (PRIT) is a multi-step method of selectively delivering high doses of radiotherapy to tumor cells while minimizing exposure to surrounding tissues. Yttrium-90 ( 90Y) and lutetium-177 ( 177Lu) are two of the most promising beta-particle emitting radionuclides used for radioimmunotherapy, which despite having similar chemistries differ distinctly in terms of radiophysical features. These differences may have important consequences for the absorbed dose to tumors and normal organs. Whereas 90Y has been successfully applied in a number of preclinical and clinical radioimmunotherapy settings, there have been few published pretargeting studies with 177Lu. We therefore compared the therapeutic potentialmore » of targeting either 90Y or 177Lu to human B-cell lymphoma xenografts in mice. Methods Parallel experiments evaluating the biodistribution, imaging, dosimetry, therapeutic efficacy, and toxicity were performed in female athymic nude mice bearing either Ramos (Burkitt lymphoma) or Granta (mantle cell lymphoma) xenografts, utilizing an anti-CD20 antibodystreptavidin conjugate (1F5-SA) and an 90Y- or 177Lu-labeled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-biotin second step reagent. Results The two radionuclides displayed comparable biodistributions in tumors and normal organs; however, the absorbed radiation dose delivered to tumor was more than twice as high for 90Y (1.3 Gy/MBq) as for 177Lu (0.6 Gy/MBq). More importantly, therapy with 90Y-DOTAbiotin was dramatically more effective than with 177Lu-DOTA-biotin, with 100% of Ramos xenograft-bearing mice cured with 37 MBq 90Y, whereas 0% were cured using identical amounts of 177Lu-DOTA-biotin. Similar results were observed in mice bearing Granta xenografts, with 80% of the mice cured with 90Y-PRIT and 0% cured with 177Lu-PRIT. Toxicities were comparable with both isotopes. Conclusion 90Y was therapeutically superior to 177Lu for streptavidin-biotin PRIT

  16. Comparative efficacy of 177Lu and 90Y for Anti-CD20 Pretargeted Radioimmunotherapy in Murine Lymphoma Xenograft Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frost, Sofia H. L.; Frayo, Shani L.; Miller, Brian W.

    Purpose Pretargeted radioimmunotherapy (PRIT) is a multi-step method of selectively delivering high doses of radiotherapy to tumor cells while minimizing exposure to surrounding tissues. Yttrium-90 ( 90Y) and lutetium-177 ( 177Lu) are two of the most promising beta-particle emitting radionuclides used for radioimmunotherapy, which despite having similar chemistries differ distinctly in terms of radiophysical features. These differences may have important consequences for the absorbed dose to tumors and normal organs. Whereas 90Y has been successfully applied in a number of preclinical and clinical radioimmunotherapy settings, there have been few published pretargeting studies with 177Lu. We therefore compared the therapeutic potentialmore » of targeting either 90Y or 177Lu to human B-cell lymphoma xenografts in mice. Methods Parallel experiments evaluating the biodistribution, imaging, dosimetry, therapeutic efficacy, and toxicity were performed in female athymic nude mice bearing either Ramos (Burkitt lymphoma) or Granta (mantle cell lymphoma) xenografts, utilizing an anti-CD20 antibodystreptavidin conjugate (1F5-SA) and an 90Y- or 177Lu-labeled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-biotin second step reagent. Results The two radionuclides displayed comparable biodistributions in tumors and normal organs; however, the absorbed radiation dose delivered to tumor was more than twice as high for 90Y (1.3 Gy/MBq) as for 177Lu (0.6 Gy/MBq). More importantly, therapy with 90Y-DOTAbiotin was dramatically more effective than with 177Lu-DOTA-biotin, with 100% of Ramos xenograft-bearing mice cured with 37 MBq 90Y, whereas 0% were cured using identical amounts of 177Lu-DOTA-biotin. Similar results were observed in mice bearing Granta xenografts, with 80% of the mice cured with 90Y-PRIT and 0% cured with 177Lu-PRIT. Toxicities were comparable with both isotopes. Conclusion 90Y was therapeutically superior to 177Lu for streptavidin-biotin PRIT

  17. Development of resins for composites by resin transfer molding

    NASA Technical Reports Server (NTRS)

    Woo, Edmund P.; Puckett, Paul M.; Maynard, Shawn J.

    1991-01-01

    Designed to cover a wide range of resin technology and to meet the near-term and long-term needs of the aircraft industry, this research has three objectives: to produce resin transfer molding (RES) resins with improved processability, to produce prepreg systems with high toughness and service temperature, and to produce new resin systems. Progress on reaching the objectives is reported.

  18. Preliminary evaluation of Glass Resin materials for solar cell cover use

    NASA Technical Reports Server (NTRS)

    Marsik, S. J.; Swartz, C. K.; Baraona, C. R.

    1978-01-01

    The glass resins were deposited by several techniques on 200 micron thick cells and on 50 microns thick wafers. The covered cells were exposed to ultraviolet light in vacuum to an intensity of 10 UV energy-equivalent solar constants at air mass zero for 728 hr. The exposure was followed by a single long thermal cycle from ambient temperature to -150 C. Visual inspection of the samples indicated that all samples had darkened to varying degrees. The loss in short-circuit current was found to range from 8 to 24%, depending on the resin formulation. In another test over 40 glass resin-coated silicon wafers withstood 15 thermal cycles from 100 to-196 C in one or more of the thicknesses tested. Several of the resin-coated wafers were tested at 65 C and 90% relative humidity for 170 hr. No change in physical appearance was detected.

  19. 40 CFR 90.909 - Export exemptions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Export exemptions. 90.909 Section 90... of Nonroad Engines from Regulations § 90.909 Export exemptions. (a) A new nonroad engine intended solely for export, and so labeled or tagged on the outside of the container and on the engine itself, is...

  20. Bioengineering of Bacteria To Assemble Custom-Made Polyester Affinity Resins

    PubMed Central

    Hay, Iain D.; Du, Jinping; Burr, Natalie

    2014-01-01

    Proof of concept for the in vivo bacterial production of a polyester resin displaying various customizable affinity protein binding domains is provided. This was achieved by engineering various protein binding domains into a bacterial polyester-synthesizing enzyme. Affinity binding domains based on various structural folds and derived from molecular libraries were used to demonstrate the potential of this technique. Designed ankyrin repeat proteins (DARPins), engineered OB-fold domains (OBodies), and VHH domains from camelid antibodies (nanobodies) were employed. The respective resins were produced in a single bacterial fermentation step, and a simple purification protocol was developed. Purified resins were suitable for most lab-scale affinity chromatography purposes. All of the affinity domains tested produced polyester beads with specific affinity for the target protein. The binding capacity of these affinity resins ranged from 90 to 600 nmol of protein per wet gram of polyester affinity resin, enabling purification of a recombinant protein target from a complex bacterial cell lysate up to a purity level of 96% in one step. The polyester resin was efficiently produced by conventional lab-scale shake flask fermentation, resulting in bacteria accumulating up to 55% of their cellular dry weight as polyester. A further proof of concept demonstrating the practicality of this technique was obtained through the intracellular coproduction of a specific affinity resin and its target. This enables in vivo binding and purification of the coproduced “target protein.” Overall, this study provides evidence for the use of molecular engineering of polyester synthases toward the microbial production of specific bioseparation resins implementing previously selected binding domains. PMID:25344238

  1. Influence of phosphoproteins' biomimetic analogs on remineralization of mineral-depleted resin-dentin interfaces created with ion-releasing resin-based systems.

    PubMed

    Sauro, Salvatore; Osorio, Raquel; Watson, Timothy F; Toledano, Manuel

    2015-07-01

    The study aimed at evaluating the remineralization of acid-etched dentin pre-treated with primers containing biomimetic analogs and bonded using an ion-releasing light-curable resin-based material. An experimental etch-and-rinse adhesive system filled with Ca(2+), PO4(3-)-releasing Ca-Silicate micro-fillers was created along with two experimental primers containing biomimetic analogs such as sodium trimetaphosphate (TMP) and/or polyaspartic acid (PLA). Dentin specimens etched with 37% H3PO4 were pre-treated with two different aqueous primers containing the polyanionic biomimetic analogs or deionized water and subsequently bonded using the experimental resin-based materials. The specimens were sectioned and analyzed by AFM/nanoindentation to evaluate changes in the modulus of elasticity (Ei) across the resin-dentin interface at different AS storage periods (up to 90 days). Raman cluster analysis was also performed to evaluate the chemical changes along the interface. The phosphate uptake by the acid-etched dentin was evaluated using the ATR-FTIR. Additional resin-dentin specimens were tested for microtensile bond strength. SEM examination was performed after de-bonding, while confocal laser microscopy was used to evaluate the interfaces ultramorphology and micropermeability. Both biomimetic primers induced phosphate uptake by acid-etched dentin. Specimens created with the ion-releasing resin in combination with the pre-treatment primers containing either PLA and TMA showed the greatest recovery of the Ei of the hybrid layer, with no decrease in μTBS (p>0.05) after 3-month AS storage. The ion-releasing resin applied after use of the biomimetic primers showed the greatest reduction in micropermeability due to mineral precipitation; these results were confirmed using SEM. The use of the ion-releasing resin-based system applied to acid-etched dentin pre-treated with biomimetic primers containing analogs of phosphoproteins such as poly-l-aspartic acid and/or sodium

  2. Fiber reinforced thermoplastic resin matrix composites

    NASA Technical Reports Server (NTRS)

    Jones, Robert J. (Inventor); Chang, Glenn E. C. (Inventor)

    1989-01-01

    Polyimide polymer composites having a combination of enhanced thermal and mechanical properties even when subjected to service temperatures as high as 700.degree. F. are described. They comprise (a) from 10 to 50 parts by weight of a thermoplastic polyimide resin prepared from 2,2-bis[4-(4-aminophenoxy)phenyl]hexafluoropropane and (b) from 90 to 50 parts by weight of continuous reinforcing fibers, the total of (a) and (b) being 100 parts by weight. Composites based on polyimide resin formed from 2,2-bis[4-(4-aminophenoxy)phenyl]hexafluoropropane and pyromellitic dianhydride and continuous carbon fibers retained at least about 50% of their room temperature shear strength after exposure to 700.degree. F. for a period of 16 hours in flowing air. Preferably, the thermoplastic polyimide resin is formed in situ in the composite material by thermal imidization of a corresponding amide-acid polymer prepared from 2,2-bis[4-(4-aminophenoxy)phenyl]hexafluoropropane. It is also preferred to initially size the continuous reinforcing fibers with up to about one percent by weight of an amide-acid polymer prepared from 2,2-bis[4-(4-aminophenoxy)phenyl]hexafluoropropane. In this way imidization at a suitable elevated temperature results in the in-situ formation of a substantially homogeneous thermoplastic matrix of the polyimide resin tightly and intimately bonded to the continuous fibers. The resultant composites tend to have optimum thermo-mechanical properties.

  3. THERAPY OF POLYCYTHEMIA VERA WITH RADIOYTTRIUM (Y-90)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greenburg, J.; Sawitsky, A.; Dudley, H.C.

    1962-01-01

    BS>Nine patients with polycythemia vera were treated from 5-l7 months ago with a single intravenous injection of chelated radioactive yttrium (Y-90) in dosages ranging from 0.l0 to 0.25 mc/kg of body weight. An excellent response, both clinical and hematologic, was obtained in all the patients. This includes relief of symptoms, regression of organomegaly, and normalization of the hematologic picture. Two of these patients, treated l6 and 9 months ago, may possibly be going into relapse. The others are continuing in essentially complete remission. Toxicity was limtted to transient petechiosis and epistaxis, from which recovery was spontaneous. (auth)

  4. A systematic review of contralateral liver lobe hypertrophy after unilobar selective internal radiation therapy with Y90.

    PubMed

    Teo, Jin-Yao; Allen, John C; Ng, David C; Choo, Su-Pin; Tai, David W M; Chang, Jason P E; Cheah, Foong-Khoon; Chow, Pierce K H; Goh, Brian K P

    2016-01-01

    Curative liver resection is the treatment of choice for both primary and secondary liver malignancies. However, an inadequate future liver remnant (FLR) frequently precludes successful surgery. Portal vein embolization is the gold-standard modality for inducing hypertrophy of the FLR. In recent times, unilobar Yttrium-90 selective internal radiation therapy (SIRT) has been reported to induce hypertrophy of the contralateral, untreated liver lobe. The aim of this study is to review the current literature reporting on contralateral liver hypertrophy induced by unilobar SIRT. A systematic review of the English-language literature between 2000 and 2014 was performed using the search terms "Yttrium 90" OR "selective internal radiation therapy" OR "radioembolization" AND "hypertrophy". Seven studies, reporting on 312 patients, were included. Two hundred and eighty four patients (91.0%) received treatment to the right lobe. Two hundred and fifteen patients had hepatocellular carcinoma (HCC), 12 had intrahepatic cholangiocarcinoma, and 85 had liver metastases from mixed primaries. Y90 SIRT resulted in contralateral liver hypertrophy which ranged from 26 to 47% at 44 days-9 months. All studies were retrospective in nature, and heterogeneous, with substantial variations relative to pathology treated, underlying liver disease, dosage and delivery of Y90, number of treatment sessions and time to measurement of hypertrophy. Unilobar Y90 SIRT results in significant hypertrophy of the contralateral liver lobe. The rate of hypertrophy seems to be slower than that achieved by other methods. Copyright © 2015 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.

  5. The Influence of Yttrium on High Temperature Oxidation of Valve Steels

    NASA Astrophysics Data System (ADS)

    Grzesik, Z.; Migdalska, M.; Mrowec, S.

    2015-04-01

    The influence of small amounts of yttrium, electrochemically deposited on the surface of four steels utilized in the production of valves in car engines, on the protective properties of the oxide scale and its adherence to the surface of the oxidized materials has been studied under isothermal and thermal cycle conditions. Oxidation measurements have been carried out at 1173 K. It has been found that yttrium addition improves considerably the scale adherence to the substrate surface, increasing thereby corrosion resistance of the studied materials.

  6. Survival of anterior cantilevered all-ceramic resin-bonded fixed dental prostheses made from zirconia ceramic.

    PubMed

    Sasse, Martin; Kern, Matthias

    2014-06-01

    This study evaluated the clinical outcome of all-ceramic resin-bonded fixed dental prostheses (RBFDPs) with a cantilevered single-retainer design made from zirconia ceramic. Forty-two anterior RBFDPs with a cantilevered single-retainer design were made from yttrium oxide-stabilized zirconium oxide ceramic. RBFDPs were inserted using Panavia 21 TC as luting agent after air-abrasion of the ceramic bonding surface. During a mean observation time of 61.8 months two debondings occurred. Both RBFDPs were rebonded using Panavia 21 TC and are still in function. A caries lesion was detected at one abutment tooth during recall and was treated with a composite filling. Therefore, the overall six-year failure-free rate according to Kaplan-Meier was 91.1%. If only debonding was defined as failure the survival rate increased to 95.2%. Since all RBFDPs are still in function the overall survival rate was 100% after six years. Cantilevered zirconia ceramic RBFDPs showed promising results within the observation period. Single-retainer resin-bonded fixed dental prostheses made from zirconia ceramic show very good mid-term clinical survival rates. They should therefore be considered as a viable treatment alternative for the replacement of single missing anterior teeth especially as compared to an implant therapy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Purification of bioactive phenolics from Phanerochaete chysosporium biomass extract on selected macroporous resins

    NASA Astrophysics Data System (ADS)

    Idris, Z. M.; Dzahir, M. I. H. M.; Jamal, P.; Barkat, A. A.; Xian, R. L. W.

    2017-06-01

    In this study, two different types of macroporous resins known as XAD-7HP and HP-20 were evaluated for the adsorption and desorption properties against bioactive phenolics extracted from Phanerochaete chrysosporium. From the previous static sorption studies, it was found that the adsorption capacity for both resins had has no significant difference. Then, the kinetic adsorption data were analyzed with both pseudo-first-order and pseudo-second-order equations and the later performed better. The adsorption isotherm data were fitted well by both Langmuir and Freundlich models. Meanwhile in desorption study, HP-20 and XAD-7HP gave 90.52% and 88.28% recoveries, respectively. Considering the desorption results of the macroporous resins, HP-20 and XAD-7HP were packed in chromatography column to further purify the phenolics. For dynamic adsorption, breakthrough capacity of HP-20 (0.522) was found to be higher than XAD-7HP (0.131). Different ethanol concentrations (30% to 50% (v/v)) were investigated at fixed flowrate (1 ml/min) on phenolics recovery from both types of resins. The highest recovery of bioactive phenolics was 94.3% using XAD-7HP resins at 50% (v/v) of ethanol. Only 77.1% of bioactive phenolics were recovered using HP-20 resin at the same experimental conditions. The purified extract subsequently was analyzed using HPLC. The results showed that three phenolics (gallic acid 3,4-dihydroxybenzoic acid and 4-hydroxybenzoic acid) were identified with higher concentrations as compared to non-purified extract. Finally, the purified extract was tested for scavenging activity against DPPH, and it showed that the activity increased significantly to 90.80% from 59.94% in non-purified extract.

  8. Yttrium recovery from primary and secondary sources: A review of main hydrometallurgical processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Innocenzi, Valentina, E-mail: valentina.innocenzi1@univaq.it; De Michelis, Ida; Kopacek, Bernd

    2014-07-15

    Highlights: • Review of the main hydrometallurgical processes to recover yttrium. • Recovery of yttrium from primary sources. • Recovery of yttrium from e-waste and other types of waste. - Abstract: Yttrium is important rare earths (REs) used in numerous fields, mainly in the phosphor powders for low-energy lighting. The uses of these elements, especially for high-tech products are increased in recent years and combined with the scarcity of the resources and the environmental impact of the technologies to extract them from ores make the recycling waste, that contain Y and other RE, a priority. The present review summarized themore » main hydrometallurgical technologies to extract Y from ores, contaminated solutions, WEEE and generic wastes. Before to discuss the works about the treatment of wastes, the processes to retrieval Y from ores are discussed, since the processes are similar and derived from those already developed for the extraction from primary sources. Particular attention was given to the recovery of Y from WEEE because the recycle of them is important not only for economical point of view, considering its value, but also for environmental impact that this could be generated if not properly disposal.« less

  9. Sol-Gel Synthesis and Antioxidant Properties of Yttrium Oxide Nanocrystallites Incorporating P-123

    PubMed Central

    Mellado-Vázquez, Rebeca; García-Hernández, Margarita; López-Marure, Arturo; López-Camacho, Perla Yolanda; Morales-Ramírez, Ángel de Jesús; Beltrán-Conde, Hiram Isaac

    2014-01-01

    Yttrium oxide (Y2O3) nanocrystallites were synthesized by mean of a sol-gel method using two different precursors. Raw materials used were yttrium nitrate and yttrium chloride, in methanol. In order to promote oxygen vacancies, P-123 poloxamer was incorporated. Synthesized systems were heat-treated at temperatures from 700 °C to 900 °C. Systems at 900 °C were prepared in the presence and absence of P-123 using different molar ratios (P-123:Y = 1:1 and 2:1). Fourier transform infrared spectroscopy (FTIR) results revealed a characteristic absorption band of Y–O vibrations typical of Y2O3 matrix. The structural phase was analyzed by X-ray diffraction (XRD), showing the characteristic cubic phase in all systems. The diffraction peak that presented the major intensity corresponded to the sample prepared from yttrium chloride incorporating P-123 in a molar ratio of P-123:Y = 2:1 at 900 °C. Crystallites sizes were determined by Scherrer equation as between 21 nm and 32 nm. Antioxidant properties were estimated by 2,2-diphenyl-1-picrylhydrazyl (DPPH•) assays; the results are discussed. PMID:28788211

  10. Diclofenac removal in urine using strong-base anion exchange polymer resins.

    PubMed

    Landry, Kelly A; Boyer, Treavor H

    2013-11-01

    One of the major sources of pharmaceuticals in the environment is wastewater effluent of which human urine contributes the majority of pharmaceuticals. Urine source separation has the potential to isolate pharmaceuticals at a higher concentration for efficient removal as well as produce a nutrient byproduct. This research investigated the efficacy of using strong-base anion exchange polymer resins to remove the widely detected and abundant pharmaceutical, diclofenac, from synthetic human urine under fresh and ureolyzed conditions. The majority of experiments were conducted using a strong-base, macroporous, polystyrene resin (Purolite A520E). Ion-exchange followed a two-step removal rate with rapid removal in 1 h and equilibrium removal in 24 h. Diclofenac removal was >90% at a resin dose of 8 mL/L in both fresh and ureolyzed urine. Sorption of diclofenac onto A520E resin was concurrent with desorption of an equivalent amount of chloride, which indicates the ion-exchange mechanism is occurring. The presence of competing ions such as phosphate and citrate did not significantly impact diclofenac removal. Comparisons of three polystyrene resins (A520E, Dowex 22, Dowex Marathon 11) as well as one polyacrylic resin (IRA958) were conducted to determine the major interactions between anion exchange resin and diclofenac. The results showed that polystyrene resins provide the highest level of diclofenac removal due to electrostatic interactions between quaternary ammonium functional groups of resin and carboxylic acid of diclofenac and non-electrostatic interactions between resin matrix and benzene rings of diclofenac. Diclofenac was effectively desorbed from A520E resin using a regeneration solution that contained 4.5% (m/m) NaCl in an equal-volume mixture of methanol and water. The greater regeneration efficiency of the NaCl/methanol-water mixture over the aqueous NaCl solution supports the importance of non-electrostatic interactions between resin matrix and benzene rings

  11. Synthesis of dense yttrium-stabilised hafnia pellets for nuclear applications by spark plasma sintering

    NASA Astrophysics Data System (ADS)

    Tyrpekl, Vaclav; Holzhäuser, Michael; Hein, Herwin; Vigier, Jean-Francois; Somers, Joseph; Svora, Petr

    2014-11-01

    Dense yttrium-stabilised hafnia pellets (91.35 wt.% HfO2 and 8.65 wt.% Y2O3) were prepared by spark plasma sintering consolidation of micro-beads synthesised by the "external gelation" sol-gel technique. This technique allows a preparation of HfO2-Y2O3 beads with homogenous yttria-hafnia solid solution. A sintering time of 5 min at 1600 °C was sufficient to produce high density pellets (over 90% of the theoretical density) with significant reproducibility. The pellets have been machined in a lathe to the correct dimensions for use as neutron absorbers in an experimental test irradiation in the High Flux Reactor (HFR) in Petten, Holland, in order to investigate the safety of americium based nuclear fuels.

  12. Using Sr Resin with mixed acid matrices

    DOE PAGES

    McLain, Derek R.; Liu, Christine; Sudowe, Ralf

    2018-03-02

    Here, the quantification of radioactive material dispersed following the release of 90Sr, whether accidental or intentional, would be of high importance. Depending on the circumstances, it is possible that the contaminated materials would need to be completely digested prior to quantification. Many sample matrices require a mixture of different acids be employed to achieve total dissolution. Unfortunately, one the most common approaches for the separation of strontium, extraction chromatography with Sr Resin, has only been fully characterized in pure mineral acid solutions. This work shows that Sr Resin can be used effectively with high concentration mixtures of nitric and hydrochloricmore » acids in the presence or absence of hydrofluoric acid, thereby potentially negating the need for conversion to a pure mineral acid matrix.« less

  13. Using Sr Resin with mixed acid matrices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLain, Derek R.; Liu, Christine; Sudowe, Ralf

    Here, the quantification of radioactive material dispersed following the release of 90Sr, whether accidental or intentional, would be of high importance. Depending on the circumstances, it is possible that the contaminated materials would need to be completely digested prior to quantification. Many sample matrices require a mixture of different acids be employed to achieve total dissolution. Unfortunately, one the most common approaches for the separation of strontium, extraction chromatography with Sr Resin, has only been fully characterized in pure mineral acid solutions. This work shows that Sr Resin can be used effectively with high concentration mixtures of nitric and hydrochloricmore » acids in the presence or absence of hydrofluoric acid, thereby potentially negating the need for conversion to a pure mineral acid matrix.« less

  14. Effect of surface treatments on the bond strength of soft denture lining materials to an acrylic resin denture base.

    PubMed

    Gundogdu, Mustafa; Yesil Duymus, Zeynep; Alkurt, Murat

    2014-10-01

    Adhesive failure between acrylic resin and resilient liner material is commonly encountered in clinical practice. The purpose of this study was to evaluate the effect of different surface treatments on the bond strength of 2 different resilient lining materials to an acrylic resin denture base. Ninety-six dumbbell-shaped specimens were fabricated from heat-polymerized acrylic resin, and 3 mm of the material was cut from the thin midsection. The specimens were divided into 6 groups according to their surface treatments: no surface treatment (control group), 36% phosphoric acid etching (acid group), erbium:yttrium-aluminum-garnet (Er:YAG) laser (laser group), airborne-particle abrasion with 50-μm Al2O3 particles (abrasion group), an acid+laser group, and an abrasion+laser group. The specimens in each group were divided into 2 subgroups according to the resilient lining material used: heat-polymerized silicone based resilient liner (Molloplast B) and autopolymerized silicone-based resilient liner (Ufi Gel P). After all of the specimens had been polymerized, they were stored in distilled water at 37°C for 1 week. A tensile bond strength test was then performed. Data were analyzed with a 2-way ANOVA, and the Sidak multiple comparison test was used to identify significant differences (α=.05). The effects of the surface treatments and resilient lining materials on the surface of the denture base resin were examined with scanning electron microscopy. The tensile bond strength was significantly different between Molloplast B and Ufi Gel P (P<.001). The specimens of the acid group had the highest tensile bond strength, whereas those of the abrasion group had the lowest tensile bond strength. The scanning electron microscopy observations showed that the application of surface treatments modified the surface of the denture base resin. Molloplast B exhibited significantly higher bond strength than Ufi Gel P. Altering the surface of the acrylic resin denture base with 36

  15. Acid etching of titanium for bonding with veneering composite resins.

    PubMed

    Ban, Seiji; Taniki, Toshio; Sato, Hideo; Kono, Hiroshi; Iwaya, Yukari; Miyamoto, Motoharu

    2006-06-01

    Commercially pure titanium (cpTi) was etched using three concentrated acids: 18% HCl, 43% H3PO4, and 48% H2SO4. The bond strengths between five types of veneering composite resin and eight cpTi treatments (involving combinations of sandblasting, acid etching in 48% H2SO4, and vacuum firing) were determined before and after 10,000 and 20,000 thermal cycles. There were no significant differences in the bond strength of resin to cpTi after etching in 48% H2SO4 at 90 degrees C for 15 minutes, at 60 degrees C for 15, 30, or 60 minutes, and after sandblasting with and without vacuum firing (p > 0.05); moreover, these treatments yielded the highest values. As for vacuum firing, it had no significant effect on resin bond strength to cpTi before or after 10,000 and 20,000 thermal cycles. We therefore concluded that acid etching in concentrated H2SO4 is a simple and effective surface modification method of titanium for bonding to veneering composite resins.

  16. Treatment Parameters and Outcome in 680 Treatments of Internal Radiation With Resin {sup 90}Y-Microspheres for Unresectable Hepatic Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kennedy, Andrew S.; McNeillie, Patrick M.S.; Dezarn, William A.

    Purpose: Radioembolization (RE) using {sup 90}Y-microspheres is an effective and safe treatment for patients with unresectable liver malignancies. Radiation-induced liver disease (RILD) is rare after RE; however, greater understanding of radiation-related factors leading to serious liver toxicity is needed. Methods and Materials: Retrospective review of radiation parameters was performed. All data pertaining to demographics, tumor, radiation, and outcomes were analyzed for significance and dependencies to develop a predictive model for RILD. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria Adverse Events Version 3.0 scale. Results: A total of 515 patients (287 men; 228 women) from 14 USmore » and 2 EU centers underwent 680 separate RE treatments with resin {sup 90}Y-microspheres in 2003-2006. Multifactorial analyses identified factors related to toxicity, including activity (GBq) Selective Internal Radiation Therapy delivered (p < 0.0001), prescribed (GBq) activity (p < 0.0001), percentage of empiric activity (GBq) delivered (p < 0.0001), number of prior liver treatments (p < 0.0008), and medical center (p < 0.0001). The RILD was diagnosed in 28 of 680 treatments (4%), with 21 of 28 cases (75%) from one center, which used the empiric method. Conclusions: There was an association between the empiric method, percentage of calculated activity delivered to the patient, and the most severe toxicity, RILD. A predictive model for RILD is not yet possible given the large variance in these data.« less

  17. OXIDATION-RESISTANT COATING ON ARTICLES OF YTTRIUM METAL

    DOEpatents

    Wilder, D.R.; Wirkus, C.D.

    1963-11-01

    A process for protecting yttrium metal from oxidation by applying thereto and firing thereon a liquid suspension of a fritted ground silicate or phosphate glass plus from 5 to 35% by weight of CeO/sub 2/ is presented. (AEC)

  18. Efficacy of Erbium, Chromium-doped:Yttrium, Scandium, Gallium, and Garnet Laser Irradiation Combined with Resin-based Tricalcium Silicate and Calcium Hydroxide on Direct Pulp Capping: A Randomized Clinical Trial.

    PubMed

    Cengiz, Esra; Yilmaz, Hasan Guney

    2016-03-01

    The purpose of this randomized clinical study was to evaluate the efficiency of erbium, chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser irradiation combined with a resin-based tricalcium silicate material and calcium hydroxide in direct pulp capping for a 6-month follow-up period. A total of 60 teeth of 60 patients between the ages of 18 and 41 years were recruited for this study. Sixty permanent vital teeth without symptoms and radiographic changes were randomly assigned to the following 4 groups (n = 15): Gr CH, the exposed area was sealed with calcium hydroxide (CH) paste; Gr laser CH, the treated area was sealed with CH paste after Er,Cr:YSGG laser irradiation at an energy level of 0.5 W without water and with 45% air; Gr TheraCal, TheraCal LC (Bisco, Schaumburg, IL) was applied directly to the exposed pulp; and Gr Laser TheraCal, TheraCal LC was applied after irradiation with an Er,Cr:YSGG laser. At the 1-week and 1-, 3-, and 6-month recall examinations, the loss of vitality, spontaneous pain, reactions to thermal stimuli and percussion, and radiographic changes were considered as failure. The success rates in the CH and TheraCal groups were 73.3% and 66.6%, respectively. These rates did not reveal any significant difference. In both laser groups, success rates were 100%. The Er,Cr:YSGG laser-irradiated TheraCal and Er,Cr:YSGG laser-irradiated CH groups showed statistically higher success rates than the TheraCal and CH groups, respectively. Er,Cr:YSGG laser irradiation at 0.5 W without water combined with pulp capping agents can be recommended for direct pulp therapy. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Microhardness of light- and dual-polymerizable luting resins polymerized through 7.5-mm-thick endocrowns.

    PubMed

    Gregor, Ladislav; Bouillaguet, Serge; Onisor, Ioana; Ardu, Stefano; Krejci, Ivo; Rocca, Giovanni Tommaso

    2014-10-01

    The complete polymerization of luting resins through thick indirect restorations is still questioned. The purpose of this study was to evaluate the degree of polymerization of light- and dual-polymerizable luting resins under thick indirect composite resin and ceramic endocrowns by means of Vickers microhardness measurements. The Vickers microhardness measurements of a light-polymerizable microhybrid composite resin and a dual-polymerizable luting cement directly polymerized in a natural tooth mold for 40 seconds with a high-power light-emitting diode lamp (control) were compared with measurements after indirect irradiation through 7.5-mm-thick composite resin and ceramic endocrowns for 3 × 90 seconds. A test-to-control microhardness values ratio of 0.80 at a depth of 0.5 mm below the surface was assumed as the criterion for adequate conversion. For the Vickers microhardness measurements of a dual-polymerizable luting cement, no differences (P>.05) were found between Vickers microhardness control values and values reported after polymerization through composite resin and ceramic endocrowns. For The Vickers microhardness measurements (±SD) of a light-polymerizable microhybrid composite resin, control values were significantly (P<.05) higher (111 ±3.3) than those reported after polymerization through composite resin (100.5 ±3.8) and ceramic (99.7 ±2.3) endocrowns. However, the hardness values of The Vickers microhardness measurements of a light-polymerizable microhybrid composite resin polymerized through the endocrowns were approximately 10% to 12% lower than those of the control values. Two-way ANOVA showed the influence of the luting material on the Vickers microhardness values (P<.05). The effect of endocrown material was not significant (P>.05). Under the conditions of this in vitro study, Vickers microhardness values of the dual-polymerizable resin cement and the light-polymerizable restorative composite resin irradiated for 3 × 90 seconds with a high

  20. Biochemical investigation of yttrium(III) complex containing 1,10-phenanthroline: DNA binding and antibacterial activity.

    PubMed

    Khorasani-Motlagh, Mozhgan; Noroozifar, Meissam; Moodi, Asieh; Niroomand, Sona

    2013-03-05

    Characterization of the interaction between yttrium(III) complex containing 1,10-phenanthroline as ligand, [Y(phen)2Cl(OH2)3]Cl2⋅H2O, and DNA has been carried out by UV absorption, fluorescence spectra and viscosity measurements in order to investigate binding mode. The experimental results indicate that the yttrium(III) complex binds to DNA and absorption is decreasing in charge transfer band with the increase in amount of DNA. The binding constant (Kb) at different temperatures as well as thermodynamic parameters, enthalpy change (ΔH°) and entropy change (ΔS°), were calculated according to relevant fluorescent data and Vant' Hoff equation. The results of interaction mechanism studies, suggested that groove binding plays a major role in the binding of the complex and DNA. The activity of yttrium(III) complex against some bacteria was tested and antimicrobial screening tests shown growth inhibitory activity in the presence of yttrium(III) complex. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. [Study on adsorption of tea polyphenol and caffine with polyamide resin].

    PubMed

    Tang, Ke-wen; Zhou, Chun-shan; Zhong, Shi-an; Zhu, Jie-ding

    2003-02-01

    The performance of adsorption of tea polyphenol and caffine with polyamide resin was investigated. The results obtained by spectrophotometry and HPLC show that the ability of adsorption of tea polyphenol with polyamide is stronger than that of caffine, in which hydrogen bond plays a very important role. The adsorption amount of caffine is 2.65 mg.g-1 with 7.5% adsorption ratio when 100 mL of 0.71 g.L-1 caffine is adsorbed on polyamide resine, but the adsorption amount of tea polyphenol is up to 148.13 mg.g-1 with 85% adsorption ratio when 700 mL of 1.98 g.L-1 tea polyphenol is adsorbed on polyamide resine. The dilution ratios of caffine and tea polyphenol are 74% and 90%, respectively, when they are diluted by 85% alcohol. The static adsorptions of caffine and tea polyphenol on polyamide resine reach equilibrium quickly in 80 min, and the plots of adsorption kinetics are nearly linear. Tea polyphenol and caffine are successfully separated on polyamide resine, and the obtained product contains more than 96% of tea polyphenol and 80% of EGCC with caffine less than 2.8%.

  2. Resin Viscosity Influence on Fiber Compaction in Tapered Resin Injection Pultrusion Manufacturing

    NASA Astrophysics Data System (ADS)

    Masuram, N. B.; Roux, J. A.; Jeswani, A. L.

    2018-06-01

    Viscosity of the liquid resin effects the chemical and mechanical properties of the pultruded composite. In resin injection pultrusion manufacturing the liquid resin is injected into a specially designed tapered injection chamber through the injection slots present on top and bottom of the chamber. The resin is injected at a pressure so as to completely wetout the fiber reinforcements inside the tapered injection chamber. As the resin penetrates through the fibers, the resin also pushes the fibers away from the wall towards the center of chamber causing compaction of the fiber reinforcements. The fibers are squeezed together due to compaction, making resin penetration more difficult; thus higher resin injection pressures are required to efficaciously penetrate through the compacted fibers and achieve complete wetout. The impact of resin viscosity on resin flow, fiber compaction, wetout and on the final product is further discussed. Injection chamber design predominantly effects the resin flow inside the chamber and the minimum injection pressure required to completely wet the fibers. Therefore, a desirable injection chamber design is such that wetout occurs at lower injection pressures and at low internal pressures inside the injection chamber.

  3. Resin Viscosity Influence on Fiber Compaction in Tapered Resin Injection Pultrusion Manufacturing

    NASA Astrophysics Data System (ADS)

    Masuram, N. B.; Roux, J. A.; Jeswani, A. L.

    2017-08-01

    Viscosity of the liquid resin effects the chemical and mechanical properties of the pultruded composite. In resin injection pultrusion manufacturing the liquid resin is injected into a specially designed tapered injection chamber through the injection slots present on top and bottom of the chamber. The resin is injected at a pressure so as to completely wetout the fiber reinforcements inside the tapered injection chamber. As the resin penetrates through the fibers, the resin also pushes the fibers away from the wall towards the center of chamber causing compaction of the fiber reinforcements. The fibers are squeezed together due to compaction, making resin penetration more difficult; thus higher resin injection pressures are required to efficaciously penetrate through the compacted fibers and achieve complete wetout. The impact of resin viscosity on resin flow, fiber compaction, wetout and on the final product is further discussed. Injection chamber design predominantly effects the resin flow inside the chamber and the minimum injection pressure required to completely wet the fibers. Therefore, a desirable injection chamber design is such that wetout occurs at lower injection pressures and at low internal pressures inside the injection chamber.

  4. [Studies on the process of Herba Clinopodii saponins purified with macroporous adsorption resin].

    PubMed

    Zhang, Yi; Yan, Dan; Han, Yumei

    2005-10-01

    To study the technological parameters of the purification process of saponins with macroporous adsorption resin. The adsorptive characteristics and elutive parameters of the process were studied by taking the elutive and purified ratio of saponins as markers. 11.4 ml of the extraction of Herba Clinopodii (crude drugs 0.2 g/ml) was purified with a column of macroporous adsorption resin (phi15 mm x H90 mm, dry weight 2.5 g) and washed with 3BV of distilled water, then eluted with 3BV of 30% ethanol and 3BV of 70% ethanol. Most of saponins were collected in the 70% ethanol. With macroporous adsorption resin adsorbing and purifying,the elutive ratio of saponins is 86.8% and the purity reaches 153.2%. So this process of applying macroporous adsorption resin to adsorb and purify Saponins is feasible.

  5. Measurement of actinides and strontium-90 in high activity waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.L. III; Nelson, M.R.

    1994-08-01

    The reliable measurement of trace radionuclides in high activity waste is important to support waste processing activities at SRS (F and H Area Waste Tanks, Extended Sludge Processing (ESP) and In-Tank precipitation (ITP) processing). Separation techniques are needed to remove high levels of gamma activity and alpha/beta interferences prior to analytical measurement. Using new extraction chromatographic resins from EiChrom Industries, Inc., the SRS Central Laboratory has developed new high speed separation methods that enable measurement of neptunium, thorium, uranium, plutonium, americium and strontium-90 in high activity waste solutions. Small particle size resin and applied vacuum are used to reduce analysismore » times and enhance column performance. Extraction chromatographic resins are easy to use and eliminate the generation of contaminated liquid organic waste.« less

  6. Alternative methods for determining shrinkage in restorative resin composites.

    PubMed

    de Melo Monteiro, Gabriela Queiroz; Montes, Marcos Antonio Japiassú Resende; Rolim, Tiago Vieira; de Oliveira Mota, Cláudia Cristina Brainer; de Barros Correia Kyotoku, Bernardo; Gomes, Anderson Stevens Leônidas; de Freitas, Anderson Zanardi

    2011-08-01

    The purpose of this study was to evaluate polymerization shrinkage of resin composites using a coordinate measuring machine, optical coherence tomography and a more widely known method, such as Archimedes Principle. Two null hypothesis were tested: (1) there are no differences between the materials tested; (2) there are no differences between the methods used for polymerization shrinkage measurements. Polymerization shrinkage of seven resin-based dental composites (Filtek Z250™, Filtek Z350™, Filtek P90™/3M ESPE, Esthet-X™, TPH Spectrum™/Dentsply 4 Seasons™, Tetric Ceram™/Ivoclar-Vivadent) was measured. For coordinate measuring machine measurements, composites were applied to a cylindrical Teflon mold (7 mm × 2 mm), polymerized and removed from the mold. The difference between the volume of the mold and the volume of the specimen was calculated as a percentage. Optical coherence tomography was also used for linear shrinkage evaluations. The thickness of the specimens was measured before and after photoactivation. Polymerization shrinkage was also measured using Archimedes Principle of buoyancy (n=5). Statistical analysis of the data was performed with ANOVA and the Games-Howell test. The results show that polymerization shrinkage values vary with the method used. Despite numerical differences the ranking of the resins was very similar with Filtek P90 presenting the lowest shrinkage values. Because of the variations in the results, reported values could only be used to compare materials within the same method. However, it is possible rank composites for polymerization shrinkage and to relate these data from different test methods. Independently of the method used, reduced polymerization shrinkage was found for silorane resin-based composite. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. Comparison of quantitative Y-90 SPECT and non-time-of-flight PET imaging in post-therapy radioembolization of liver cancer

    PubMed Central

    Yue, Jianting; Mauxion, Thibault; Reyes, Diane K.; Lodge, Martin A.; Hobbs, Robert F.; Rong, Xing; Dong, Yinfeng; Herman, Joseph M.; Wahl, Richard L.; Geschwind, Jean-François H.; Frey, Eric C.

    2016-01-01

    Purpose: Radioembolization with yttrium-90 microspheres may be optimized with patient-specific pretherapy treatment planning. Dose verification and validation of treatment planning methods require quantitative imaging of the post-therapy distribution of yttrium-90 (Y-90). Methods for quantitative imaging of Y-90 using both bremsstrahlung SPECT and PET have previously been described. The purpose of this study was to compare the two modalities quantitatively in humans. Methods: Calibration correction factors for both quantitative Y-90 bremsstrahlung SPECT and a non-time-of-flight PET system without compensation for prompt coincidences were developed by imaging three phantoms. The consistency of these calibration correction factors for the different phantoms was evaluated. Post-therapy images from both modalities were obtained from 15 patients with hepatocellular carcinoma who underwent hepatic radioembolization using Y-90 glass microspheres. Quantitative SPECT and PET images were rigidly registered and the total liver activities and activity distributions estimated for each modality were compared. The activity distributions were compared using profiles, voxel-by-voxel correlation and Bland–Altman analyses, and activity-volume histograms. Results: The mean ± standard deviation of difference in the total activity in the liver between the two modalities was 0% ± 9% (range −21%–18%). Voxel-by-voxel comparisons showed a good agreement in regions corresponding roughly to treated tumor and treated normal liver; the agreement was poorer in regions with low or no expected activity, where PET appeared to overestimate the activity. The correlation coefficients between intrahepatic voxel pairs for the two modalities ranged from 0.86 to 0.94. Cumulative activity volume histograms were in good agreement. Conclusions: These data indicate that, with appropriate reconstruction methods and measured calibration correction factors, either Y-90 SPECT/CT or Y-90 PET/CT can be used

  8. Comparison of quantitative Y-90 SPECT and non-time-of-flight PET imaging in post-therapy radioembolization of liver cancer.

    PubMed

    Yue, Jianting; Mauxion, Thibault; Reyes, Diane K; Lodge, Martin A; Hobbs, Robert F; Rong, Xing; Dong, Yinfeng; Herman, Joseph M; Wahl, Richard L; Geschwind, Jean-François H; Frey, Eric C

    2016-10-01

    Radioembolization with yttrium-90 microspheres may be optimized with patient-specific pretherapy treatment planning. Dose verification and validation of treatment planning methods require quantitative imaging of the post-therapy distribution of yttrium-90 (Y-90). Methods for quantitative imaging of Y-90 using both bremsstrahlung SPECT and PET have previously been described. The purpose of this study was to compare the two modalities quantitatively in humans. Calibration correction factors for both quantitative Y-90 bremsstrahlung SPECT and a non-time-of-flight PET system without compensation for prompt coincidences were developed by imaging three phantoms. The consistency of these calibration correction factors for the different phantoms was evaluated. Post-therapy images from both modalities were obtained from 15 patients with hepatocellular carcinoma who underwent hepatic radioembolization using Y-90 glass microspheres. Quantitative SPECT and PET images were rigidly registered and the total liver activities and activity distributions estimated for each modality were compared. The activity distributions were compared using profiles, voxel-by-voxel correlation and Bland-Altman analyses, and activity-volume histograms. The mean ± standard deviation of difference in the total activity in the liver between the two modalities was 0% ± 9% (range -21%-18%). Voxel-by-voxel comparisons showed a good agreement in regions corresponding roughly to treated tumor and treated normal liver; the agreement was poorer in regions with low or no expected activity, where PET appeared to overestimate the activity. The correlation coefficients between intrahepatic voxel pairs for the two modalities ranged from 0.86 to 0.94. Cumulative activity volume histograms were in good agreement. These data indicate that, with appropriate reconstruction methods and measured calibration correction factors, either Y-90 SPECT/CT or Y-90 PET/CT can be used for quantitative post-therapy monitoring of Y

  9. Foam, Foam-resin composite and method of making a foam-resin composite

    NASA Technical Reports Server (NTRS)

    MacArthur, Doug E. (Inventor); Cranston, John A. (Inventor)

    1995-01-01

    This invention relates to a foam, a foam-resin composite and a method of making foam-resin composites. The foam set forth in this invention comprises a urethane modified polyisocyanurate derived from an aromatic amino polyol and a polyether polyol. In addition to the polyisocyanurate foam, the composite of this invention further contains a resin layer, wherein the resin may be epoxy, bismaleimide, or phenolic resin. Such resins generally require cure or post-cure temperatures of at least 350.degree. F.

  10. Proton trapping in yttrium-doped barium zirconate

    NASA Astrophysics Data System (ADS)

    Yamazaki, Yoshihiro; Blanc, Frédéric; Okuyama, Yuji; Buannic, Lucienne; Lucio-Vega, Juan C.; Grey, Clare P.; Haile, Sossina M.

    2013-07-01

    The environmental benefits of fuel cells have been increasingly appreciated in recent years. Among candidate electrolytes for solid-oxide fuel cells, yttrium-doped barium zirconate has garnered attention because of its high proton conductivity, particularly in the intermediate-temperature region targeted for cost-effective solid-oxide fuel cell operation, and its excellent chemical stability. However, fundamental questions surrounding the defect chemistry and macroscopic proton transport mechanism of this material remain, especially in regard to the possible role of proton trapping. Here we show, through a combined thermogravimetric and a.c. impedance study, that macroscopic proton transport in yttrium-doped barium zirconate is limited by proton-dopant association (proton trapping). Protons must overcome the association energy, 29 kJ mol-1, as well as the general activation energy, 16 kJ mol-1, to achieve long-range transport. Proton nuclear magnetic resonance studies show the presence of two types of proton environment above room temperature, reflecting differences in proton-dopant configurations. This insight motivates efforts to identify suitable alternative dopants with reduced association energies as a route to higher conductivities.

  11. Proton trapping in yttrium-doped barium zirconate.

    PubMed

    Yamazaki, Yoshihiro; Blanc, Frédéric; Okuyama, Yuji; Buannic, Lucienne; Lucio-Vega, Juan C; Grey, Clare P; Haile, Sossina M

    2013-07-01

    The environmental benefits of fuel cells have been increasingly appreciated in recent years. Among candidate electrolytes for solid-oxide fuel cells, yttrium-doped barium zirconate has garnered attention because of its high proton conductivity, particularly in the intermediate-temperature region targeted for cost-effective solid-oxide fuel cell operation, and its excellent chemical stability. However, fundamental questions surrounding the defect chemistry and macroscopic proton transport mechanism of this material remain, especially in regard to the possible role of proton trapping. Here we show, through a combined thermogravimetric and a.c. impedance study, that macroscopic proton transport in yttrium-doped barium zirconate is limited by proton-dopant association (proton trapping). Protons must overcome the association energy, 29 kJ mol(-1), as well as the general activation energy, 16 kJ mol(-1), to achieve long-range transport. Proton nuclear magnetic resonance studies show the presence of two types of proton environment above room temperature, reflecting differences in proton-dopant configurations. This insight motivates efforts to identify suitable alternative dopants with reduced association energies as a route to higher conductivities.

  12. Process Optimization of Bismaleimide (BMI) Resin Infused Carbon Fiber Composite

    NASA Technical Reports Server (NTRS)

    Ehrlich, Joshua W.; Tate, LaNetra C.; Cox, Sarah B.; Taylor, Brian J.; Wright, M. Clara; Caraccio, Anne J.; Sampson, Jeffery W.

    2013-01-01

    Bismaleimide (BMI) resins are an attractive new addition to world-wide composite applications. This type of thermosetting polyimide provides several unique characteristics such as excellent physical property retention at elevated temperatures and in wet environments, constant electrical properties over a vast array of temperature settings, and nonflammability properties as well. This makes BMI a popular choice in advance composites and electronics applications [I]. Bismaleimide-2 (BMI-2) resin was used to infuse intermediate modulus 7 (IM7) based carbon fiber. Two panel configurations consisting of 4 plies with [+45deg, 90deg]2 and [0deg]4 orientations were fabricated. For tensile testing, a [90deg]4 configuration was tested by rotating the [0deg]4 configirration to lie orthogonal with the load direction of the test fixture. Curing of the BMI-2/IM7 system utilized an optimal infusion process which focused on the integration of the manufacturer-recommended ramp rates,. hold times, and cure temperatures. Completion of the cure cycle for the BMI-2/IM7 composite yielded a product with multiple surface voids determined through visual and metallographic observation. Although the curing cycle was the same for the three panellayups, the surface voids that remained within the material post-cure were different in abundance, shape, and size. For tensile testing, the [0deg]4 layup had a 19.9% and 21.7% greater average tensile strain performance compared to the [90deg]4 and [+45deg, 90deg, 90deg,-45degg] layups, respectively, at failure. For tensile stress performance, the [0deg]4 layup had a 5.8% and 34.0% greater average performance% than the [90deg]4 and [+45deg, 90deg, 90deg,-45deg] layups.

  13. Fast Determination of Yttrium and Rare Earth Elements in Seawater by Inductively Coupled Plasma-Mass Spectrometry after Online Flow Injection Pretreatment.

    PubMed

    Zhu, Zuhao; Zheng, Airong

    2018-02-23

    A method for daily monitoring of yttrium and rare earth elements (YREEs) in seawater using a cheap flow injection system online coupled to inductively coupled plasma-mass spectrometry is reported. Toyopearl AF Chelate 650M ® resin permits separation and concentration of YREEs using a simple external calibration. A running cycle consumed 6 mL sample and took 5.3 min, providing a throughput of 11 samples per hour. Linear ranges were up to 200 ng kg -1 except Tm (100 ng kg -1 ). The precision of the method was <6% (RSDs, n = 5), and recoveries ranged from 93% to 106%. Limits of detection (LODs) were in the range 0.002 ng kg -1 (Tm) to 0.078 ng kg -1 (Ce). Good agreement between YREEs concentrations in CASS-4 and SLEW-3 obtained in this work and results from other studies was observed. The proposed method was applied to the determination of YREEs in seawater from the Jiulong River Estuary and the Taiwan Strait.

  14. Comparison of resin film infusion, resin transfer molding, and consolidation of textile preforms for primary aircraft structure

    NASA Technical Reports Server (NTRS)

    Suarez, J.; Dastin, S.

    1992-01-01

    Under NASA's Novel Composites for Wing and Fuselage Applications (NCWFA) Program, Grumman is developing innovative design concepts and cost-effective fabrication processes for damage-tolerant primary structures that can perform at a design ultimate strain level of 6000 micro-inch/inch. Attention has focused on the use of textile high-performance fiber-reinforcement concepts that provide improved damage tolerance and out-of-plane load capability, low-cost resin film infusion (RFI) and resin transfer molding (RTM) processes, and thermoplastic forming concepts. The fabrication of wing 'Y' spars by four different materials/processes methods is described: 'Y' spars fabricated using IM7 angle interlock 0/90 deg woven preforms with +/- 45 deg plies stitched with Toray high-strength graphite thread and processed using RFI and 3501-6 epoxy; 'Y' spars fabricated using G40-800 knitted/stitched preforms and processed using RFI and 3501-6 epoxy; 'Y' spars fabricated using G40-800 knitted/stitched preforms and processed using RTM and Tactix 123/H41 epoxy; and 'Y' spars fabricated using AS4(6k)/PEEK 150-g commingled angle interlock 0/90 deg woven preforms with +/- 45 deg commingled plies stitched using high-strength graphite thread and processed by consolidation. A comparison of the structural efficiency, processability, and projected acquisition cost of these representative spars is presented.

  15. Preliminary evaluation of glass resin materials for solar cell cover use. [on spacecraft

    NASA Technical Reports Server (NTRS)

    Marsik, S. J.; Swartz, C. K.; Baraona, C. R.

    1978-01-01

    Silicon solar cells and silicon wafers coated with a heat-curable resin consisting of alternating Si-O atoms were subjected to three tests to evaluate the potential utility of this coating in space environments. These included UV irradiation in vacuum at an intensity of 10 air mass zero UV energy-equivalent solar constants for 728 hours followed by a long thermal cycle; 15 thermal shock cycles between 100 C and minus 196 C; and high temperature and humidity (65 C at 90% relative humidity). The UV tests resulted in a 8 to 24% loss in short-circuit current and darkening of the covers. Modification of the resin to provide a better match between the coefficients of expansion of the resin and silicon improved resistance to thermal shock, but also increased the darkening effect under UV irradiation. Silicon wafers coated with the resin were not adversely affected by the temperature/humidity test.

  16. The effect of yttrium and thorium on the oxidation behavior of Ni-Cr-Al alloys

    NASA Technical Reports Server (NTRS)

    Kumar, A.; Nasrallah, M.; Douglass, D. L.

    1974-01-01

    The effect of quaternary additions of 0.5% Y, 0.5 and 1.0% Th to a base alloy of Ni-10CR-5Al on the oxidation behavior and mechanism was studied during oxidation in air over the range of 1000 to 1200 C. The presence of yttrium decreased the oxidation kinetics slightly, whereas, the addition of thorium caused a slight increase. Oxide scale adherence was markedly improved by the addition of the quaternary elements. Although a number of oxides formed on yttrium containing alloys, quantitative X-ray diffraction clearly showed that the rate-controlling step was the diffusion of aluminum through short circuit paths in a thin layer of alumina that formed parabolically with time. Although the scale adherence of the yttrium containing alloy was considerably better than the base alloys, spalling did occur that was attributed to the formation of the voluminous YAG particles which grew in a mushroom-like manner, lifting the protective scale off the subrate locally. The YAG particles formed primarily at grain boundaries in the substrate in which the yttrium originally existed as YNi9.

  17. The reactive element effect of yttrium and yttrium silicon on high temperature oxidation of NiCrAl coating

    NASA Astrophysics Data System (ADS)

    Ramandhany, S.; Sugiarti, E.; Desiati, R. D.; Martides, E.; Junianto, E.; Prawara, B.; Sukarto, A.; Tjahjono, A.

    2018-03-01

    The microstructure formed on the bond coat affects the oxidation resistance, particularly the formation of a protective oxide layer. The adhesion of bond coat and TGO increased significantly by addition of reactive element. In the present work, the effect of yttrium and yttrium silicon as reactive element (RE) on NiCrAl coating was investigated. The NiCrAl (without RE) and NiCrAlX (X:Y or YSi) bond coating were deposited on Hastelloy C-276 substrate by High Velocity Oxygen Fuel (HVOF) method. Isothermal oxidation was carried out at 1000 °C for 100 hours. The results showed that the addition of RE could prevent the breakaway oxidation. Therefore, the coating with reactive element were more protective against high temperature oxidation. Furthermore, the oxidation rate of NiCrAlY coating was lower than NiCrAlYSi coating with the total mass change was ±2.394 mg/cm2 after 100 hours of oxidation. The thickness of oxide scale was approximately 1.18 μm consisting of duplex oxide scale of spinel NiCr2O4 in outer scale and protective α-Al2O3 in inner scale.

  18. A Study on Factors Affecting the Degradation of Magnesium and a Magnesium-Yttrium Alloy for Biomedical Applications

    PubMed Central

    Johnson, Ian; Liu, Huinan

    2013-01-01

    Controlling degradation of magnesium or its alloys in physiological saline solutions is essential for their potential applications in clinically viable implants. Rapid degradation of magnesium-based materials reduces the mechanical properties of implants prematurely and severely increases alkalinity of the local environment. Therefore, the objective of this study is to investigate the effects of three interactive factors on magnesium degradation, specifically, the addition of yttrium to form a magnesium-yttrium alloy versus pure magnesium, the metallic versus oxide surfaces, and the presence versus absence of physiological salt ions in the immersion solution. In the immersion solution of phosphate buffered saline (PBS), the magnesium-yttrium alloy with metallic surface degraded the slowest, followed by pure magnesium with metallic or oxide surfaces, and the magnesium-yttrium alloy with oxide surface degraded the fastest. However, in deionized (DI) water, the degradation rate showed a different trend. Specifically, pure magnesium with metallic or oxide surfaces degraded the slowest, followed by the magnesium-yttrium alloy with oxide surface, and the magnesium-yttrium alloy with metallic surface degraded the fastest. Interestingly, only magnesium-yttrium alloy with metallic surface degraded slower in PBS than in DI water, while all the other samples degraded faster in PBS than in DI water. Clearly, the results showed that the alloy composition, presence or absence of surface oxide layer, and presence or absence of physiological salt ions in the immersion solution all influenced the degradation rate and mode. Moreover, these three factors showed statistically significant interactions. This study revealed the complex interrelationships among these factors and their respective contributions to degradation for the first time. The results of this study not only improved our understanding of magnesium degradation in physiological environment, but also presented the key

  19. Effects of blood contamination on resin-resin bond strength.

    PubMed

    Eiriksson, Sigurdur O; Pereira, Patricia N R; Swift, Edward J; Heymann, Harald O; Sigurdsson, Asgeir

    2004-02-01

    Incremental placement and curing of resin composites has been recommended. However, this requires longer operating time, and therefore, increased risk of contamination. The purpose of this study was to evaluate the effects of blood contamination on microtensile bond strengths (microTBS) between resin interfaces and to determine the best decontamination method to re-establish the original resin-resin bond strength. The top surfaces of 64, 4-mm composite blocks (Z-250, Renew, APX, Pertac II) were untreated as the control, or were treated as follows: blood applied and dried on the surface (Treatment 1), blood applied, rinsed, dried (Treatment 2), blood applied, rinsed, and an adhesive applied (Single Bond, One-Step, Clearfil SE, Prompt L-Pop) (Treatment 3). Fresh composite was applied and light-cured in 2-mm increments. After 24 h storage in water, the specimens were sectioned into 0.7-mm thick slabs, trimmed to a cross-sectional area of 1 mm(2), and loaded to failure at a crosshead speed of 1 mm/min using an Instron universal testing machine. Data were analyzed using two-way ANOVA and Fisher's PLSD test (p<0.05). Control values ranged from 45.1 MPa for Pertac II to 71.5 MPa for APX. Untreated blood contamination resulted in resin-resin bond strengths of only 1.0-13.1 MPa. Rinsing raised bond strengths to over 40 MPa for each material. Use of an adhesive further increased bond strengths except for Pertac II. Rinsing blood from contaminated surfaces increases the resin-resin bond strength significantly and the application of an appropriate adhesive increases the bond strength to control levels.

  20. Bond strength durability of self-etching adhesives and resin cements to dentin.

    PubMed

    Chaves, Carolina de Andrade Lima; de Melo, Renata Marques; Passos, Sheila Pestana; Camargo, Fernanda Pelógia; Bottino, Marco Antonio; Balducci, Ivan

    2009-01-01

    To evaluate the microtensile bond strength (microTBS) of one- (Xeno III, Dentsply) and two-step (Tyrian-One Step Plus, Bisco) self-etching adhesive systems bonded to dentin and cemented to chemically cured (C&B Metabond) or light-cured paste of a dual-cure resin cement (Variolink II, Ivoclar) within a short (24 h) and long period of evaluation (90 days). Forty recently extracted human molars had their roots removed and their occlusal dentin exposed and ground wet with 600-grit SiC paper. After application of one of the adhesives, the resin cement was applied to the bonded surface and a composite resin block was incrementally built up to a height of 5 mm (n=10). The restored teeth were stored in distilled water at 37 degrees C for 7 days. The teeth were then cut along two axes (x and y), producing beam-shaped specimens with 0.8 mm(2) cross-sectional area, which were subjected to microTBS testing at a crosshead speed of 0.05 mm/min and stressed to failure after 24 h or 90 days of storage in water. The microTBS data in MPa were subjected to three-way analysis of variance and Tukey's test (alpha= 0.05). The interaction effect for all three factors was statistically significant (three-way ANOVA, p<0.001). All eight experimental means (MPa) were compared by the Tukey's test (p<0.05) and the following results were obtained: Tyrian-One Step Plus /C&B/24 h (22.4+/-7.3); Tyrian-One Step Plus /Variolink II/24 h (39.4+/-11.6); Xeno III/C&B/24 h (40.3+/-12.9); Xeno III/Variolink II/24 h (25.8+/-10.5); Tyrian-One Step Plus /C&B/90 d (22.1+/-12.8) Tyrian-One Step Plus/VariolinkII/90 d (24.2+/-14.2); Xeno III/C&B/90 d (27.0+/-13.5); Xeno III/Variolink II/90 d (33.0+/-8.9). Xeno III/Variolink II was the luting agent/adhesive combination that provided the most promising bond strength after 90 days of storage in water.

  1. BOND STRENGTH DURABILITY OF SELF-ETCHING ADHESIVES AND RESIN CEMENTS TO DENTIN

    PubMed Central

    Chaves, Carolina de Andrade Lima; de Melo, Renata Marques; Passos, Sheila Pestana; Camargo, Fernanda Pelógia; Bottino, Marco Antonio; Balducci, Ivan

    2009-01-01

    Objectives: To evaluate the microtensile bond strength (μTBS) of one- (Xeno III, Dentsply) and two-step (Tyrian-One Step Plus, Bisco) self-etching adhesive systems bonded to dentin and cemented to chemically cured (C&B Metabond) or light-cured paste of a dual-cure resin cement (Variolink II, Ivoclar) within a short (24 h) and long period of evaluation (90 days). Material and Methods: Forty recently extracted human molars had their roots removed and their occlusal dentin exposed and ground wet with 600-grit SiC paper. After application of one of the adhesives, the resin cement was applied to the bonded surface and a composite resin block was incrementally built up to a height of 5 mm (n=10). The restored teeth were stored in distilled water at 37°C for 7 days. The teeth were then cut along two axes (x and y), producing beam-shaped specimens with 0.8 mm2 cross-sectional area, which were subjected to μTBS testing at a crosshead speed of 0.05 mm/min and stressed to failure after 24 h or 90 days of storage in water. The μTBS data in MPa were subjected to three-way analysis of variance and Tukey's test (α= 0.05). Results: The interaction effect for all three factors was statistically significant (three-way ANOVA, p<0.001). All eight experimental means (MPa) were compared by the Tukey's test (p<0.05) and the following results were obtained: Tyrian-One Step Plus/C&B/24 h (22.4±7.3); Tyrian-One Step Plus/Variolink II/24 h (39.4±11.6); Xeno III/C&B/24 h (40.3±12.9); Xeno III/Variolink II/24 h (25.8±10.5); Tyrian-One Step Plus/C&B/90 d (22.1±12.8) Tyrian-One Step Plus/VariolinkII/90 d (24.2±14.2); Xeno III/C&B/90 d (27.0±13.5); Xeno III/Variolink II/ 90 d (33.0±8.9). Conclusions: Xeno III/Variolink II was the luting agent/adhesive combination that provided the most promising bond strength after 90 days of storage in water. PMID:19466243

  2. Linear and volumetric dimensional changes of injection-molded PMMA denture base resins.

    PubMed

    El Bahra, Shadi; Ludwig, Klaus; Samran, Abdulaziz; Freitag-Wolf, Sandra; Kern, Matthias

    2013-11-01

    The aim of this study was to evaluate the linear and volumetric dimensional changes of six denture base resins processed by their corresponding injection-molding systems at 3 time intervals of water storage. Two heat-curing (SR Ivocap Hi Impact and Lucitone 199) and four auto-curing (IvoBase Hybrid, IvoBase Hi Impact, PalaXpress, and Futura Gen) acrylic resins were used with their specific injection-molding technique to fabricate 6 specimens of each material. Linear and volumetric dimensional changes were determined by means of a digital caliper and an electronic hydrostatic balance, respectively, after water storage of 1, 30, or 90 days. Means and standard deviations of linear and volumetric dimensional changes were calculated in percentage (%). Statistical analysis was done using Student's and Welch's t tests with Bonferroni-Holm correction for multiple comparisons (α=0.05). Statistically significant differences in linear dimensional changes between resins were demonstrated at all three time intervals of water immersion (p≤0.05), with exception of the following comparisons which showed no significant difference: IvoBase Hi Impact/SR Ivocap Hi Impact and PalaXpress/Lucitone 199 after 1 day, Futura Gen/PalaXpress and PalaXpress/Lucitone 199 after 30 days, and IvoBase Hybrid/IvoBase Hi Impact after 90 days. Also, statistically significant differences in volumetric dimensional changes between resins were found at all three time intervals of water immersion (p≤0.05), with exception of the comparison between PalaXpress and Futura Gen. Denture base resins (IvoBase Hybrid and IvoBase Hi Impact) processed by the new injection-molding system (IvoBase), revealed superior dimensional precision. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. An in vitro evaluation of wear and surface roughness of particulate filler composite resin after tooth brushing.

    PubMed

    Al Khuraif, Abdul Aziz A

    2014-11-01

    To evaluate the influence of tooth brushing on wear and surface roughness of four different particulate filler composite resins. Six specimens (2 mm thick and 8 mm in diameter) of each tested material (Filtek Z250-Microhybrid, SpectrumTPH3-Submicron hybrid, Filtek Z350XT Nanofiller and Filtek P90- Microhybrid) were prepared according to the manufacturer's directions. A brushing sequence of 5000, 10,000 and 20,000 cycles was performed for all the samples. A non-contact profilometer was used to determine average surface roughness (Ra) and wear of the material assessed using an analytic electronic balance at baseline and each cycle interval. The data obtained were analyzed using one-way ANOVAs and post-hoc multiple comparison tests. Paired t-test was used for comparisons between cycle intervals for each material. Analyses with scanning electron microscopy (SEM) were also performed. The resin composite Filtek P 90 presented an increase in percentage weight loss after final toothbrushing cycles over the rest of the materials. Brushing significantly increased roughness (Ra) for all composites. Filtek Z250, after brushing, was significantly rougher than the other resins followed by Filtek P 90, Spectrum TPH 3 and Filtek Z350 XT. However, SEM images indicated severe change in surface topography of 'sub-micron hybrid' specimen compared to each other after tooth brushing. Wear and surface roughness increased with each cycle interval for all the materials and one composite resin demonstrated a higher increase in surface roughness than the other three tested brands of composite resins. Not much difference was observed in the weight loss between tested samples.

  4. Ecological Dose Modeling of Aquatic and Riparian Receptors to Strontium-90 with an Emphasis on Radiosensitive Organs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poston, Ted M.; Traub, Richard J.; Antonio, Ernest J.

    2011-07-20

    The 100-NR-2 site is the location of elevated releases of strontium-90 to the Columbia River via contaminated groundwater. The resulting dose to aquatic and riparian receptors was evaluated in 2005 (DOE 2009) and compared to U.S. Department of Energy (DOE) dose guidance values. We have conducted additional dose assessments for a broader spectrum of aquatic and riparian organisms using RESRAD Biota and specific exposure scenarios. Because strontium-90 accumulates in bone, we have also modeled the dose to the anterior kidney, a blood-forming and immune system organ that lies close to the spinal column of fish. The resulting dose is primarilymore » attributable to the yttrium-90 progeny of strontium-90 and very little of the dose is associated with the beta emission from strontium-90. All dose modeling results were calculated with an assumption of secular equilibrium between strontium-90 and yttrum-90.« less

  5. MO-A-BRD-00: Current Trends in Y90-Microsphere Therapy: Delivery and Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    Yttrium-90 (Y90) microsphere therapy, a form of radiation therapy, is an increasingly popular option for care of patients with liver metastases or unresectable hepatocellular carcinoma. The therapy directly delivers Y90 microspheres via the hepatic artery to disease sites. Following delivery, a vast majority of microspheres preferentially lodge in the capillary vessels due to their embolic size and targeted trans-arterial delivery – depositing up to 90% of its energy in the first 5 mm of tissue. There have been a number of advances in tomographic imaging within both interventional radiology and nuclear medicine that has advanced therapy planning techniques. Quantitative imagingmore » of Y90 microsphere distribution post-therapy has also seen innovations that have led to improvements in tumor dosimetry and characterization of tumor response. A review of current trends and recent innovation in Y90 microsphere therapies will be presented. Learning Objectives: To present the imaging requirements for Y90 microsphere therapy planning To explain the standard dosimetry models used in Y90 microsphere therapy planning To report on advances in imaging for therapy planning and posttherapy assessment of tumor dosimetry and response.« less

  6. Process Optimization of Bismaleimide (BMI) Resin Infused Carbon Fiber Composite

    NASA Technical Reports Server (NTRS)

    Ehrlich, Joshua W.; Tate, LaNetra C.; Cox, Sarah B.; Taylor, Brian J.; Wright, M. Clara; Faughnan, Patrick D.; Batterson, Lawrence M.; Caraccio, Anne J.; Sampson, Jeffery W.

    2013-01-01

    Engineers today are presented with the opportunity to design and build the next generation of space vehicles out of the lightest, strongest, and most durable materials available. Composites offer excellent structural characteristics and outstanding reliability in many forms that will be utilized in future aerospace applications including the Commercial Crew and Cargo Program and the Orion space capsule. NASA's Composites for Exploration (CoEx) project researches the various methods of manufacturing composite materials of different fiber characteristics while using proven infusion methods of different resin compositions. Development and testing on these different material combinations will provide engineers the opportunity to produce optimal material compounds for multidisciplinary applications. Through the CoEx project, engineers pursue the opportunity to research and develop repair patch procedures for damaged spacecraft. Working in conjunction with Raptor Resins Inc., NASA engineers are utilizing high flow liquid infusion molding practices to manufacture high-temperature composite parts comprised of intermediate modulus 7 (IM7) carbon fiber material. IM7 is a continuous, high-tensile strength composite with outstanding structural qualities such as high shear strength, tensile strength and modulus as well as excellent corrosion, creep, and fatigue resistance. IM7 carbon fiber, combined with existing thermoset and thermoplastic resin systems, can provide improvements in material strength reinforcement and deformation-resistant properties for high-temperature applications. Void analysis of the different layups of the IM7 material discovered the largest total void composition within the [ +45 , 90 , 90 , -45 ] composite panel. Tensile and compressional testing proved the highest mechanical strength was found in the [0 4] layup. This paper further investigates the infusion procedure of a low-cost/high-performance BMI resin into an IM7 carbon fiber material and the

  7. Photonuclear production of yttrium-88 - A high energy gamma emitter for hydrocarbon extraction applications.

    PubMed

    Dale, Daniel S; Starovoitova, Valeriia N; Forest, Tony A; Oliphant, Emily

    2018-05-05

    The use of fracing has risen over the past decade and revolutionized energy production in the US. However, there is still an impetus for further optimization of the extraction of oil and natural gas from vast shale reservoirs. In this work, we discuss photonuclear production of yttrium-88 as a promising radiotracer for fracing operations. Single neutron knock-out from natural monoisotopic yttrium-89 is an inexpensive process resulting in high activity of 88 Y with minimal impurities. MCNPX simulations were performed to estimate the 88 Y yield. Irradiations of natural yttrium using a 32 MeV electron linac equipped with a tungsten bremsstrahlung converter were done to benchmark the simulations. Activities of 88 Y, 87g Y, and 87m Y were measured and found to be in good agreement with the predictions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Quantitative description of yttrium aluminate ceramic composition by means of Er+3 microluminescence spectrum

    NASA Astrophysics Data System (ADS)

    Videla, F. A.; Tejerina, M. R.; Moreira-Osorio, L.; Conconi, M. S.; Orzi, D. J. O.; Flores, T.; Ponce, L. V.; Bilmes, G. M.; Torchia, G. A.

    2018-05-01

    The composition of erbium-doped yttrium aluminate ceramics was analyzed by means of confocal luminescence spectroscopy, EDX, and X-ray diffraction. A well-defined linear correlation was found between a proposed estimator computed from the luminescence spectrum and the proportion of ceramic phases coexisting in different samples. This result shows the feasibility of using erbium luminescence spectroscopy to perform a quantitative determination of different phases of yttrium aluminates within a micrometric region in nanograined ceramics.

  9. Evaluation of Efficacy of Radioimmunotherapy with 90Y-Labeled Fully Human Anti-Transferrin Receptor Monoclonal Antibody in Pancreatic Cancer Mouse Models

    PubMed Central

    Sugyo, Aya; Tsuji, Atsushi B.; Sudo, Hitomi; Okada, Maki; Koizumi, Mitsuru; Satoh, Hirokazu; Kurosawa, Gene; Kurosawa, Yoshikazu; Saga, Tsuneo

    2015-01-01

    Objective Pancreatic cancer is an aggressive tumor and the prognosis remains poor. Therefore, development of more effective therapy is needed. We previously reported that 89Zr-labeled TSP-A01, an antibody against transferrin receptor (TfR), is highly accumulated in a pancreatic cancer xenograft, but not in major normal organs. In the present study, we evaluated the efficacy of radioimmunotherapy (RIT) with 90Y-TSP-A01 in pancreatic cancer mouse models. Methods TfR expression in pancreatic cancer cell lines (AsPC-1, BxPC-3, MIAPaCa-2) was evaluated by immunofluorescence staining. 111In-labeled anti-TfR antibodies (TSP-A01, TSP-A02) were evaluated in vitro by cell binding assay with the three cell lines and by competitive inhibition assay with MIAPaCa-2. In vivo biodistribution was evaluated in mice bearing BxPC-3 and MIAPaCa-2 xenografts. Tumor volumes of BxPC-3 and MIAPaCa-2 were sequentially measured after 90Y-TSP-A01 injection and histological analysis of tumors was conducted. Results MIAPaCa-2 cells showed the highest TfR expression, followed by AsPC-1 and BxPC-3 cells. 111In-TSP-A01 and 111In-TSP-A02 bound specifically to the three cell lines according to TfR expression. The dissociation constants for TSP-A01, DOTA-TSP-A01, TSP-A02, and DOTA-TSP-A02 were 0.22, 0.28, 0.17, and 0.22 nM, respectively. 111In-TSP-A01 was highly accumulated in tumors, especially in MIAPaCa-2, but this was not true of 111In-TSP-A02. The absorbed dose for 90Y-TSP-A01 was estimated to be 8.3 Gy/MBq to BxPC-3 and 12.4 Gy/MBq to MIAPaCa-2. MIAPaCa-2 tumors treated with 3.7 MBq of 90Y-TSP-A01 had almost completely disappeared around 3 weeks after injection and regrowth was not observed. Growth of BxPC-3 tumors was inhibited by 3.7 MBq of 90Y-TSP-A01, but the tumor size was not reduced. Conclusion 90Y-TSP-A01 treatment achieved an almost complete response in MIAPaCa-2 tumors, whereas it merely inhibited the growth of BxPC-3 tumors. 90Y-TSP-A01 is a promising RIT agent for pancreatic cancer

  10. Phonon anharmonicity of monoclinic zirconia and yttrium-stabilized zirconia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Chen W.; Smith, Hillary L.; Lan, Tian

    2015-04-13

    Inelastic neutron scattering measurements on monoclinic zirconia (ZrO 2) and 8 mol% yttrium-stabilized zirconia were performed at temperatures from 300 to 1373 ωK. We reported temperature-dependent phonon densities of states (DOS) and Raman spectra obtained at elevated temperatures. First-principles lattice dynamics calculations with density functional theory gave total and partial phonon DOS curves and mode Grüneisen parameters. These mode Grüneisen parameters were used to predict the experimental temperature dependence of the phonon DOS with partial success. However, substantial anharmonicity was found at elevated temperatures, especially for phonon modes dominated by the motions of oxygen atoms. Yttrium-stabilized zirconia (YSZ) was somewhatmore » more anharmonic and had a broader phonon spectrum at low temperatures, owing in part to defects in its structure. YSZ also has a larger vibrational entropy than monoclinic zirconia.« less

  11. Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monsky, Wayne L., E-mail: wayne.monsky@ucdmc.ucdavis.edu; Garza, Armando S.; Kim, Isaac

    Purpose: The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. Methods: Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Threemore » observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. Results: Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan-Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). Conclusion: Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival.« less

  12. Method of forming a relatively stable slip of silicon metal particles and yttrium containing particles

    DOEpatents

    Dickie, Ray A.; Mangels, John A.

    1984-01-01

    The method concerns forming a relatively stable slip of silicon metal particles and yttrium containing particles. In one embodiment, a casting slip of silicon metal particles is formed in water. Particles of a yttrium containing sintering aid are added to the casting slip. The yttrium containing sintering aid is a compound which has at least some solubility in water to form Y.sup.+3 ions which have a high potential for totally flocculating the silicon metal particles into a semiporous solid. A small amount of a fluoride salt is added to the casting slip which contains the yttrium containing sintering aid. The fluoride salt is one which will produce fluoride anions when dissolved in water. The small amount of the fluoride anions produced are effective to suppress the flocculation of the silicon metal particles by the Y.sup.+3 ions so that all particles remain in suspension in the casting slip and the casting slip has both an increased shelf life and can be used to cast articles having a relatively thick cross-section. The pH of the casting slip is maintained in a range from 7.5 to 9. Preferably, the fluoride salt used is one which is based on a monovalent cation such as sodium or ammonia. The steps of adding the yttrium containing sintering aid and the fluoride salt may be interchanged if desired, and the salt may be added to a solution containing the sintering aid prior to addition of the silicon metal particles.

  13. Characterization of yttrium-rich precipitates in a titanium alloy weld

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolli, R. Prakash, E-mail: pkolli@umd.edu

    The yttrium-rich (Y-rich) precipitates that form in the fusion zone (FZ) of a Ti–5Al–1Sn–1Zr–1V–0.8Mo (wt.%) alloy, or Ti-5111, gas-tungsten arc welds (GTAW) were characterized. The filler metal was modified by a small concentration of Y in order to refine the microstructure and thus improve the FZ ductility. A high number density of nanoscale Y-rich precipitates were characterized in the weld FZ by atom probe tomography (APT) and scanning transmission electron microscopy (STEM). - Highlights: •A high number density of nanoscale precipitates were observed in the FZ matrix. •The nanoscale precipitates are enriched in yttrium. •Oxygen and sulfur are also presentmore » in the Y-rich precipitates and their interfaces.« less

  14. Effects of yttrium, aluminum, and chromium concentrations in bond coatings on the performance of zirconia-yttria thermal barriers

    NASA Technical Reports Server (NTRS)

    Stecura, S.

    1979-01-01

    A cyclic furnace study was conducted between 990 - 280 C and 1095 - 280 C to evaluate the effects of yttrium, chromium, and aluminum concentrations in nickel base alloy bond coatings and also the effect of the bond coating thickness on the performance of yttria-stabilized zirconia thermal barrier coatings. The presence and the concentration of yttrium is very critical. Without yttrium, rapid oxidation of Ni-Al, Ni-Cr, and Ni-Cr-Al bond coatings causes zirconia thermal barrier coatings to fail very rapidly. Concentrations of chrominum and aluminum in Ni-Cr-Al-Y bond coating have a very significant effect on the thermal barrier coating life. This effect, however, is not as great as that due to yttrium. Furthermore, the thickness and the thickness uniformity also have a very significant effect on the life of the thermal barrier system.

  15. In-column immobilization of Cs-saturated crystalline silicotitanates using phenolic resins.

    PubMed

    Curi, Rodrigo F; Luca, Vittorio

    2018-03-01

    The in situ immobilization of granulated Cs-saturated crystalline silicotitanates (Cs-CST) in fixed-bed columns has been investigated using commercially available phenol formaldehyde (PF) resin as a binding agent. Two types of PF resin were investigated as part of this study both being prepared from resol polymer having a formaldehyde:phenol ratio of 3:1. However, one of the resol polymers had water as the primary solvent and the other ethanol. Both resol polymers were observed to completely infiltrate the space between the Cs-CST beads and also the pores within the beads themselves. PF resin monoliths prepared after curing the water-based resol at 180 °C were considerably less porous than the ethanol-based counterparts cured under the same conditions. The enhanced macroporosity of the resin prepared from the ethanol-based resol was presumably the result from enhanced gas bubble generation. Little or no micro- or mesoporosity was measured using nitrogen porosimetry. For both resins cured at 180 °C, intimate contacts with the Cs-CST beads were observed that were not modified even after complete immersion in water over long time frames. Little or no migration of Cs from Cs-CST to the resin binder was observed. The compressive strength of the Cs-CST-PF resin monoliths was measured and benchmarked against cement monoliths and was found to be two to three times higher than cement in the case of the water-based resin. Leaching of the monoliths was conducted in demineralized water at 90 °C. Normalized Cs mass losses of the order of 1.0 g/m 2 were measured after 30 days for the ethanol-based resin monoliths. For the less porous water-based monoliths, the normalized mass loss was one order of magnitude lower. The leaching of monoliths irradiated with a 2-MGy dose of γ radiation showed no difference in Cs mass loss suggesting that the ability to retain Cs of either the CST or PF resin was not affected. PF resins are capable of acting as a mechanically robust

  16. Evaluation of effect of laser etching on shear bond strength between maxillofacial silicone and acrylic resin subjected to accelerated aging process.

    PubMed

    Rhea, Antonette; Ahila, S C; Kumar, B Muthu

    2017-01-01

    Maxillofacial prosthesis are supported by implants, require a retentive matrix to retain the suprastructure. The retentive matrix is made up of acrylic resin to which the silicone prostheses are anchored by micro-mechanical bond. The delamination of silicone away from the retentive matrix is a persisting problem in implant-supported maxillofacial prosthesis. This study aimed to evaluate the effect of laser etching on the shear bond strength (BS) between acrylic resin and maxillofacial silicone, after 24 h of fabrication and after 200 h of accelerated aging. The samples were prepared according to ISO/TR 11405:1994 in maxillofacial silicone and polymethyl methacrylate resin. The untreated samples were Group A (control), Group B (silicon carbide [SiC] paper abrasion 80 grit size), and Group C (erbium-doped yttrium aluminum garnet laser etching). Then, the samples were coated with primer and bonded to maxillofacial silicone. The samples were subjected to shear BS test in an universal testing machine after 24 h of fabrication and after 200 h of accelerated aging. The results were statistically analyzed using one-way ANOVA and Tukey's HSD post hoc test. The shear BS test after 24 h of fabrication showed better BS in SiC paper abrasion. The shear BS test after 200 h of accelerated aging showed better BS in laser etching compared to SiC abrasion. Laser etching produced better shear BS compared to conventional SiC paper abrasion after 200 h of accelerated aging process.

  17. Mechanical properties of silorane-based and methacrylate-based composite resins after artificial aging.

    PubMed

    de Castro, Denise Tornavoi; Lepri, César Penazzo; Valente, Mariana Lima da Costa; dos Reis, Andréa Cândido

    2016-01-01

    The aim of this study was to compare the compressive strength of a silorane-based composite resin (Filtek P90) to that of conventional composite resins (Charisma, Filtek Z250, Fill Magic, and NT Premium) before and after accelerated artificial aging (AAA). For each composite resin, 16 cylindrical specimens were prepared and divided into 2 groups. One group underwent analysis of compressive strength in a universal testing machine 24 hours after preparation, and the other was subjected first to 192 hours of AAA and then the compressive strength test. Data were analyzed by analysis of variance, followed by the Tukey HSD post hoc test (α = 0.05). Some statistically significant differences in compressive strength were found among the commercial brands (P < 0.001). The conventional composite resin Fill Magic presented the best performance before (P < 0.05) and after AAA (P < 0.05). Values for compressive strength of the silorane-based composite were among the lowest obtained, both before and after aging. Comparison of each material before and after AAA revealed that the aging process did not influence the compressive strength of the tested resins (P = 0.785).

  18. Enhanced DOC removal using anion and cation ion exchange resins.

    PubMed

    Arias-Paic, Miguel; Cawley, Kaelin M; Byg, Steve; Rosario-Ortiz, Fernando L

    2016-01-01

    Hardness and DOC removal in a single ion exchange unit operation allows for less infrastructure, is advantageous for process operation and depending on the water source, could enhance anion exchange resin removal of dissolved organic carbon (DOC). Simultaneous application of cationic (Plus) and anionic (MIEX) ion exchange resin in a single contact vessel was tested at pilot and bench scales, under multiple regeneration cycles. Hardness removal correlated with theoretical predictions; where measured hardness was between 88 and 98% of the predicted value. Comparing bench scale DOC removal of solely treating water with MIEX compared to Plus and MIEX treated water showed an enhanced DOC removal, where removal was increased from 0.5 to 1.25 mg/L for the simultaneous resin application compared to solely applying MIEX resin. A full scale MIEX treatment plant (14.5 MGD) reduced raw water DOC from 13.7 mg/L to 4.90 mg/L in the treated effluent at a bed volume (BV) treatment rate of 800, where a parallel operation of a simultaneous MIEX and Plus resin pilot (10 gpm) measured effluent DOC concentrations of no greater than 3.4 mg/L, even at bed volumes of treatment 37.5% greater than the full scale plant. MIEX effluent compared to simultaneous Plus and MIEX effluent resulted in differences in fluorescence intensity that correlated to decreases in DOC concentration. The simultaneous treatment of Plus and MIEX resin produced water with predominantly microbial character, indicating the enhanced DOC removal was principally due to increased removal of terrestrially derived organic matter. The addition of Plus resin to a process train with MIEX resin allows for one treatment process to remove both DOC and hardness, where a single brine waste stream can be sent to sewer at a full-scale plant, completely removing lime chemical addition and sludge waste disposal for precipitative softening processes. Published by Elsevier Ltd.

  19. Phenoxy resins containing pendent ethynyl groups and cured resins obtained therefrom

    NASA Technical Reports Server (NTRS)

    Hergenrother, P. M. (Inventor)

    1985-01-01

    Phenoxy resins containing pendent ethynyl groups, the process for preparing the same, and the cured resin products obtained therefrom are disclosed. Upon the application of heat, the ethynyl groups react to provide branching and crosslinking with the cure temperature being lowered by using a catalyst if desired but not required. The cured phenoxy resins containing pendent ethynyl groups have improved solvent resistance and higher use temperature than linear uncrosslinked phenoxy resins and are applicable for use as coatings, films, adhesives, composited matrices and molding compounds.

  20. Effect of Er:YAG laser irradiation on bonding property of zirconia ceramics to resin cement.

    PubMed

    Lin, Yihua; Song, Xiaomeng; Chen, Yaming; Zhu, Qingping; Zhang, Wei

    2013-12-01

    This study aimed to investigate whether or not an erbium: yttrium-aluminum-garnet (Er:YAG) laser could improve the bonding property of zirconia ceramics to resin cement. Surface treatments can improve the bonding properties of dental ceramics. However, little is known about the effect of Er:YAG laser irradiated on zirconia ceramics. Specimens of zirconia ceramic pieces were made, and randomly divided into 11 groups according to surface treatments, including one control group (no treatment), one air abrasion group, and nine Er:YAG laser groups. The laser groups were subdivided by applying different energy intensities (100, 200, or 300 mJ) and irradiation times (5, 10, or 15 sec). After surface treatments, ceramic pieces had their surface morphology observed, and their surface roughness was measured. All specimens were bonded to resin cement. Shear bond strength was measured after the bonded specimens were stored in water for 24 h, and additionally aged by thermocycling. Statistical analyses were performed using one way analysis of variance (ANOVA) and Tukey's test for shear bond strength, and Dunnett's t test for surface roughness, with α=0.05. Er:YAG laser irradiation changed the morphological characteristics of zirconia ceramics. Higher energy intensities (200, 300 mJ) could roughen the ceramics, but also caused surface cracks. There were no significant differences in the bond strength between the control group and the laser groups treated with different energy intensities or irradiation times. Air abrasion with alumina particles induced highest surface roughness and shear bond strength. Er:YAG laser irradiation cannot improve the bonding property of zirconia ceramics to resin cement. Enhancing irradiation intensities and extending irradiation time have no benefit on the bond of the ceramics, and might cause material defect.

  1. Pilot evaluation of four experimental conditioning treatments to improve the bond strength between resin cement and Y-TZP ceramic.

    PubMed

    Monaco, Carlo; Cardelli, Paolo; Scotti, Roberto; Valandro, Luiz Felipe

    2011-02-01

    This study evaluated the bond strength between resin cement and Y-TZP ceramic (Yttrium-stabilized Tetragonal Zirconia Polycrystalline) submitted to different surface conditionings. Fifty Y-TZP ceramic discs (Ø= 10 mm) were allocated into five groups: Gr1 (control)-no conditioning; Gr2-tribochemical silica coating (30-μm SiO(2)) before sintering; Gr3-air abrasion with 50-μm Al(2)O(3) before sintering; Gr4-air abrasion with 110-μ Al(2)O(3) before sintering; Gr5 - air abrasion with 50-μm Al(2)O(3) after sintering. After specimen preparation, cylinders of composite resin were prepared and immediately cemented onto the ceramic. A shear test was performed. One-way ANOVA indicated a statistically significant difference among the groups (p= 0.0019). The mean shear bond strengths (MPa) were: Gr1 = 4.7 ± 0.8,(b) Gr2 = 4.6 ± 0.9,(b) Gr3 = 6.4 ± 1.0,(a) Gr4 = 6.5 ± 1.8,(a) Gr5 = 6 ± 1.3(ab) (same superscript letter indicates statistical similarity). Adhesive fracture between the ceramic and resin cement was the most common failure. No complete cohesive fracture at the ceramic or composite cylinders was noted. Within the limitations of this study, additional surface treatment with air abrasion before and after sintering provided a significant increase in bond strength. Tribochemical silica coating before sintering was not effective as a surface treatment. © 2011 by The American College of Prosthodontists.

  2. Resin-Powder Dispenser

    NASA Technical Reports Server (NTRS)

    Standfield, Clarence E.

    1994-01-01

    Resin-powder dispenser used at NASA's Langley Research Center for processing of composite-material prepregs. Dispenser evenly distributes powder (resin polymer and other matrix materials in powder form) onto wet uncured prepregs. Provides versatility in distribution of solid resin in prepreg operation. Used wherever there is requirement for even, continuous distribution of small amount of powder.

  3. Low Melt Viscosity Resins for Resin Transfer Molding

    NASA Technical Reports Server (NTRS)

    Harris, Frank W.

    2002-01-01

    In recent years, resin transfer molding (RTM) has become one of the methods of choice for high performance composites. Its cost effectiveness and ease of fabrication are major advantages of RTM. RTM process usually requires resins with very low melt viscosity (less than 10 Poise). The optimum RTM resins also need to display high thennal-oxidative stability, high glass transition temperature (T(sub g)), and good toughness. The traditional PMR-type polyimides (e.g. PMR-15) do not fit this requirement, because the viscosities are too high and the nadic endcap cures too fast. High T(sub g), low-melt viscosity resins are highly desirable for aerospace applications and NASA s Reusable Launch Vehicle (RLV) program. The objective of this work is to prepare low-melt viscosity polyimide resins for RTM or resin film infusion (RFI) processes. The approach involves the synthesis of phenylethynyl-terminated imide oligomers. These materials have been designed to minimize their melt viscosity so that they can be readily processed. During the cure, the oligomers undergo both chain extension and crosslinking via the thermal polymerization of the phenylethynyl groups. The Phenylethynyl endcap is preferred over the nadic group due to its high curing temperature, which provides broader processing windows. This work involved the synthesis and polymerization of oligomers containing zig-zag backbones and twisted biphenyl structures. Some A-B type precursors which possessed both nitro and anhydride functionality, or both nitro and amine functionality, were also synthesized in order to obtain the well defined oligomers. The resulting zig-zag structured oligomers were then end-capped with 4-phenylethynylphthalic anhydride (PEPA) for further cure. The properties of these novel imide oligomers are evaluated.

  4. MCrAlY bond coat with enhanced Yttrium layer

    DOEpatents

    Jablonski, Paul D; Hawk, Jeffrey A

    2015-04-21

    One or more embodiments relates to an MCrAlY bond coat comprising an MCrAlY layer in contact with a Y--Al.sub.2O.sub.3 layer. The MCrAlY layer is comprised of a .gamma.-M solid solution, a .beta.-MAl intermetallic phase, and Y-type intermetallics. The Y--Al.sub.2O.sub.3 layer is comprised of Yttrium atoms coordinated with oxygen atoms comprising the Al.sub.2O.sub.3 lattice. Both the MCrAlY layer and the Y--Al.sub.2O.sub.3 layer have a substantial absence of Y--Al oxides, providing advantage in the maintainability of the Yttrium reservoir within the MCrAlY bulk. The MCrAlY bond coat may be fabricated through application of a Y.sub.2O.sub.3 paste to an MCrAlY material, followed by heating in a non-oxidizing environment.

  5. Effect of Shade and Light Curing Mode on the Degree of Conversion of Silorane-Based and Methacrylate-Based Resin Composites.

    PubMed

    Sm, Mousavinasab; M, Atai; N, Salehi; A, Salehi

    2016-12-01

    The degree of conversion depends on the material composition, light source properties, distance from light source, light intensity, curing time, and other factors such as shade and translucency. In the present study, we evaluated the effects of different light-curing modes and shades of methacrylate and silorane-based resin composites on the degree of conversion of resin composites (DC). The methacrylate-based (Filtek Z250, 3M, ESPE) and low-shrinkage silorane-based (Filtek P90, 3M, ESPE) resin composites were used in three groups as follows: group 1-Filtek Z250 (shade A3), group 2-Filtek Z250 (shade B2), and group 3-Filtek P90 (shade A3). We used a light-emitting diode (LED) curing unit for photopolymerization. 10 samples were prepared in each group to evaluate the degree of conversion; 5 samples were cured using soft-start curing mode, and the other 5 were cured using standard curing mode. The DC of the resin composites was measured using Fourier Transform Infrared Spectroscopy (FTIR). The data were analyzed using Kruskal Wallis and one-way ANOVA statistical tests. The degree of conversion of silorane-based resin composite was 70 - 75.8% and that of methacrylate-based resin composites was 60.2 - 68.2% (p = 0.009). The degree of conversion of the composite with brighter colour (B2) was statistically more than the darker composite (A3). Higher degree of conversion was achieved applying the standard curing mode. The results of the study showed that the colour and type of the resin composite and also the curing mode influence the degree of conversion of resin composites.

  6. Analysis of the microstructure and mechanical performance of composite resins after accelerated artificial aging.

    PubMed

    De Oliveira Daltoé, M; Lepri, C Penazzo; Wiezel, J Guilherme G; Tornavoi, D Cremonezzi; Agnelli, J A Marcondes; Reis, A Cândido Dos

    2013-03-01

    Researches that assess the behavior of dental materials are important for scientific and industrial development especially when they are tested under conditions that simulate the oral environment, so this work analyzed the compressive strength and microstructure of three composite resins subjected to accelerated artificial aging (AAA). Three composites resins of 3M (P90, P60 and Z100) were analyzed and were obtained 16 specimens for each type (N.=48). Half of each type were subjected to UV-C system AAA and then were analyzed the surfaces of three aged specimens and three not aged of each type through the scanning electron microscope (SEM). After, eight specimens of each resin, aged and not aged, were subjected to compression test. After statistical analysis of compressive strength values, it was found that there was difference between groups (α <0.05). The resin specimens aged P60 presented lower values of compressive strength statistically significant when compared to the not subject to the AAA. For the other composite resins, there was no difference, regardless of aging, a fact confirmed by SEM. The results showed that the AAA influenced the compressive strength of the resin aged P60; confirmed by surface analysis by SEM, which showed greater structural disarrangement on surface material.

  7. Isotope shifts from collinear laser spectroscopy of doubly charged yttrium isotopes

    NASA Astrophysics Data System (ADS)

    Vormawah, L. J.; Vilén, M.; Beerwerth, R.; Campbell, P.; Cheal, B.; Dicker, A.; Eronen, T.; Fritzsche, S.; Geldhof, S.; Jokinen, A.; Kelly, S.; Moore, I. D.; Reponen, M.; Rinta-Antila, S.; Stock, S. O.; Voss, A.

    2018-04-01

    Collinear laser spectroscopy has been performed on doubly charged ions of radioactive yttrium in order to study the isotope shifts of the 294.6-nm 5 s 1/2 2S →5 p 1/2 2P line. The potential of such an alkali-metal-like transition to improve the reliability of atomic-field-shift and mass-shift factor calculations, and hence the extraction of nuclear mean-square radii, is discussed. Production of yttrium ion beams for such studies is available at the IGISOL IV Accelerator Laboratory, Jyväskylä, Finland. This newly recommissioned facility is described here in relation to the on-line study of accelerator-produced short-lived isotopes using collinear laser spectroscopy and application of the technique to doubly charged ions.

  8. Equivalent Young's modulus of composite resin for simulation of stress during dental restoration.

    PubMed

    Park, Jung-Hoon; Choi, Nak-Sam

    2017-02-01

    For shrinkage stress simulation in dental restoration, the elastic properties of composite resins should be acquired beforehand. This study proposes a formula to measure the equivalent Young's modulus of a composite resin through a calculation scheme of the shrinkage stress in dental restoration. Two types of composite resins remarkably different in the polymerization shrinkage strain were used for experimental verification: the methacrylate-type (Clearfil AP-X) and the silorane-type (Filtek P90). The linear shrinkage strains of the composite resins were gained through the bonded disk method. A formula to calculate the equivalent Young's moduli of composite resin was derived on the basis of the restored ring substrate. Equivalent Young's moduli were measured for the two types of composite resins through the formula. Those values were applied as input to a finite element analysis (FEA) for validation of the calculated shrinkage stress. Both of the measured moduli through the formula were appropriate for stress simulation of dental restoration in that the shrinkage stresses calculated by the FEA were in good agreement within 3.5% with the experimental values. The concept of equivalent Young's modulus so measured could be applied for stress simulation of 2D and 3D dental restoration. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. The influence of implanted yttrium on the cyclic oxidation behaviour of 304 stainless steel

    NASA Astrophysics Data System (ADS)

    Riffard, F.; Buscail, H.; Caudron, E.; Cueff, R.; Issartel, C.; Perrier, S.

    2006-03-01

    High-temperature alloys are frequently used in power plants, gasification systems, petrochemical industry, combustion processes and in aerospace applications. Depending on the application, materials are subjected to corrosive atmospheres and thermal cycling. In the present work, thermal cycling was carried out in order to study the influence of implanted yttrium on the oxide scale adherence on 304 steel specimens oxidised in air at 1273 K. In situ X-ray diffraction indicates that the oxides formed at 1273 K are different on blank specimens compared to implanted specimens. Glancing angle XRD allows to analyse the oxide scale composition after cooling to room temperature. Experimental results show that yttrium implantation at a nominal dose of 10 17 ions cm -2 does not improve significantly the cyclic oxidation behaviour of the austenitic AISI 304 steel. However, it appears that yttrium implantation remarkably enhance the oxidation resistance during isothermal oxidation. It reduces the transient oxidation stage and the parabolic oxidation rate constant by one order of magnitude.

  10. Fractionated Radioimmunotherapy With 90Y-Clivatuzumab Tetraxetan and Low-Dose Gemcitabine Is Active in Advanced Pancreatic Cancer

    PubMed Central

    Ocean, Allyson J.; Pennington, Kenneth L.; Guarino, Michael J.; Sheikh, Arif; Bekaii-Saab, Tanios; Serafini, Aldo N.; Lee, Daniel; Sung, Max W.; Gulec, Seza A.; Goldsmith, Stanley J.; Manzone, Timothy; Holt, Michael; O’Neil, Bert H.; Hall, Nathan; Montero, Alberto J.; Kauh, John; Gold, David V.; Horne, Heather; Wegener, William A.; Goldenberg, David M.

    2014-01-01

    BACKGROUND It has been demonstrated that the humanized clivatuzumab tetraxetan (hPAM4) antibody targets pancreatic ductal carcinoma selectively. After a trial of radioimmunotherapy that determined the maximum tolerated dose of single-dose yttrium-90-labeled hPAM4 (90Y-hPAM4) and produced objective responses in patients with advanced pancreatic ductal carcinoma, the authors studied fractionated radioimmunotherapy combined with low-dose gemcitabine in this disease. METHODS Thirty-eight previously untreated patients (33 patients with stage IV disease and 5 patients with stage III disease) received gemcitabine 200 mg/m2 weekly for 4 weeks with 90Y-hPAM4 given weekly in Weeks 2, 3, and 4 (cycle 1), and the same cycle was repeated in 13 patients (cycles 2–4). In the first part of the study, 19 patients received escalating weekly 90Y doses of 6.5 mCi/m2, 9.0 mCi/m2, 12.0 mCi/m2, and 15.0 mCi/m2. In the second portion, 19 additional patients received weekly doses of 9.0 mCi/m2 or 12.0 mCi/m2. RESULTS Grade 3/4 thrombocytopenia or neutropenia (according to version 3.0 of the National Cancer Institute’s Common Terminology Criteria for Adverse Events) developed in 28 of 38 patients after cycle 1 and in all retreated patients; no grade >3 nonhematologic toxicities occurred. Fractionated dosing of cycle 1 allowed almost twice the radiation dose compared with single-dose radioimmunotherapy. The maximum tolerated dose of 90Y-hPAM4 was 12.0 mCi/m2 weekly for 3 weeks for cycle 1, with ≤9.0 mCi/m2 weekly for 3 weeks for subsequent cycles, and that dose will be used in future trials. Six patients (16%) had partial responses according to computed tomography-based Response Evaluation Criteria in Solid Tumors, and 16 patients (42%) had stabilization as their best response (58% disease control). The median overall survival was 7.7 months for all 38 patients, including 11.8 months for those who received repeated cycles (46% [6 of 13 patients] ≥1 year), with improved efficacy at

  11. Evaluating the improvement of corrosion residual strength by adding 1.0 wt.% yttrium into an AZ91D magnesium alloy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Qiang; Liu Yaohui, E-mail: liuyaohui2005@yahoo.com; Fang Shijie

    2010-06-15

    The influence of yttrium on the corrosion residual strength of an AZ91D magnesium alloy was investigated detailedly. Scanning electron microscope was employed to analyze the microstructure and the fractography of the studied alloys. The microstructure of AZ91D magnesium alloy is remarkably refined due to the addition of yttrium. The electrochemical potentiodynamic polarization curve of the studied alloy was performed with a CHI 660b electrochemical station in the three-electrode system. The result reveals that yttrium significantly promotes the overall corrosion resistance of AZ91D magnesium alloy by suppressing the cathodic reaction in corrosion process. However, the nucleation and propagation of corrosion pitsmore » on the surface of the 1.0 wt.% Y modified AZ91D magnesium alloy indicate that pitting corrosion still emerges after the addition of yttrium. Furthermore, stress concentration caused by corrosion pits should be responsible for the drop of corrosion residual strength although the addition of yttrium remarkably weakens the effect of stress concentration at the tip of corrosion pits in loading process.« less

  12. An improved method for the rapid determination of 90Sr in cow's milk.

    PubMed

    Guérin, Nicolas; Riopel, Remi; Rao, Ray; Kramer-Tremblay, Sheila; Dai, Xiongxin

    2017-09-01

    An improved method was developed to rapidly determine strontium-90 ( 90 Sr) in cow's milk samples in the event of a nuclear emergency. To perform this method, no heating or ashing steps were needed and all of the material used was disposable. Stable Sr tracer was added to each 40 mL milk sample. Hydrochloric acid (HCl) and trichloroacetic acid (TCA) were added to the sample to flocculate the suspended fat and proteins in the milk. The sample was centrifuged and the strontium in the supernatant was precipitated with carbonate. The resulting precipitate was dissolved in 8 M HNO 3 and the solution was passed through a Sr resin to remove potential interferents. Strontium was eluted from the resin using a small volume of water. Strontium-90 was measured by liquid-scintillation counting (LSC) and the tracer by inductively coupled plasma mass spectrometry (ICP-MS). The figures of merit of the method were determined and the method was validated using spiked samples. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  13. Fissure sealant materials: Wear resistance of flowable composite resins

    PubMed Central

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm2 and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm2of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics. PMID:27651887

  14. Fissure sealant materials: Wear resistance of flowable composite resins.

    PubMed

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  15. Hydrothermal synthesis, crystal structures and photoluminescence properties of mixed europium-yttrium organic frameworks

    NASA Astrophysics Data System (ADS)

    Han, Yinfeng; Fu, Lianshe; Mafra, Luís; Shi, Fa-Nian

    2012-02-01

    Three mixed europium-yttrium organic frameworks: Eu2-xYx(Mel)(H2O)6 (Mel=mellitic acid or benzene-1,2,3,4,5,6-hexacarboxylic acid, x=0.38 1, 0.74 2, and 0.86 3) have been synthesized and characterized. All the compounds contain a 3-D net with (4, 8)-flu topology. The study indicates that the photoluminescence properties are effectively affected by the different ratios of europium and yttrium ions, the quantum efficiency is increased and the Eu3+ lifetime becomes longer in these MOFs than those of the Eu analog.

  16. A peristaltic pump driven 89Zr separation module

    NASA Astrophysics Data System (ADS)

    Siikanen, J.; Peterson, M.; Tran, T. A.; Roos, P.; Ohlsson, T.; Sandell, A.

    2012-12-01

    To facilitate the separation of 89Zr produced in yttrium foils, an automated separation module was designed and assembled. The module separates more than 85% of produced 89Zr - activity in 3 g foils in less than 90 min. About 10 % remains in the dissolving vial. The quality of the separated 89Zr activity was investigated for labeling of the HER2-binding monoclonal antibody fragment, trastuzumab-Fab.

  17. 7 CFR 160.90 - False, misleading, or deceitful practices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Section 160.90 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) NAVAL STORES REGULATIONS AND STANDARDS FOR NAVAL STORES Labeling, Advertising and Packing § 160.90 False, misleading, or...

  18. 21 CFR 175.380 - Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...-isopropylidenediphenol-epichlorohydrin epoxy resins. 175.380 Section 175.380 Food and Drugs FOOD AND DRUG ADMINISTRATION...,4′-isopropylidenediphenol-epichlorohydrin epoxy resins. The resins identified in paragraph (a) of... condensation of xylene-formaldehyde resin and 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins, to...

  19. Study of the effects of adding Yttrium oxide particles in some physical, thermal, and mechanical properties of heat-curing acrylic resin

    NASA Astrophysics Data System (ADS)

    Khalil, Bassam I.; Gharkan, Mohammed R.; Ali, Ahmed H.

    2018-05-01

    Extensively use of hot-curing acrylic in prosthetic dentistry field, increase the needed to modifying its mechanical, thermal, and physical properties. In this work Yttrium oxide had added with different weight fractions, (5%, 10%, 15% and 20%), as reinforcement phase on purpose of developing these properties. Tensile strength, hardness, density, water adsorption, and thermal conductivity had been investigated for prepared composite specimens. The results show that the maximum tensile strength was at (10) % wt. of Y2O3 addition, (19) %more than that of plain acrylic, maximum hardness was at (15) % wt. of Y2O3 addition, (8.5) % more than that of plain acrylic, maximum density was at (20) % wt. of Y2O3 addition, (18.2) % more than that of plain acrylic, maximum decrease in water absorption was at (10) % wt. of Y2O3 addition, (29) % less than that of plain acrylic. Finally the maximum thermal conductivity was at (20) % wt. of Y2O3 addition, (16) % more than that of plain acrylic.

  20. Correlations of norbornenyl crosslinked polyimide resin structures with resin thermo-oxidative stability, resin glass transition temperature and composite initial mechanical properties

    NASA Technical Reports Server (NTRS)

    Alston, William B.

    1988-01-01

    PMR (polymerization of monomeric reactants) methodology was used to prepare 70 different polyimide oligomeric resins and 30 different unidirectional graphite fiber/polyimide composites. Monomeric composition as well as chain length between sites of crosslinks were varied to examine their effects on resin thermo-oxidative stability and glass transition temperature (Tg) of the cured/postcured resins. A linear correlation of decreasing 316 C resin weight loss/surface area versus (1) decreasing aliphatic content, or (2) increasing benzylic/aliphatic content stoichiometry ratio over a wide range of resin compositions was observed. An almost linear correlation of Tg versus molecular distance between the crosslinks was also observed. An attempt was made to correlate Tg with initial composite mechanical properties (flexural strength and interlaminar shear strength). However, the scatter in mechanical strength data prevented obtaining a clear correlation. Instead, only a range of composite mechanical properties was obtained at 25, 288, and 316 C. Perhaps more importantly, what did become apparent during the correlation study was (1) the PMR methodology could be used to prepare composites from resins containing a wide variety of monomer modifications, (2) that these composites almost invariably provided satisfactory initial mechanical properties as long as the resins formulated exhibited satisfactory processing flow, and (3) that PMR resins exhibited predictable rates of 316 C weight loss/surface area based on their benzylic/aliphatic stoichiometery ratio.

  1. Fabrication of dense yttrium oxyfluoride ceramics by hot pressing and their mechanical, thermal, and electrical properties

    NASA Astrophysics Data System (ADS)

    Tahara, Ryuki; Tsunoura, Toru; Yoshida, Katsumi; Yano, Toyohiko; Kishi, Yukio

    2018-06-01

    Excellent corrosion-resistant materials have been strongly required to reduce particle contamination during the plasma process in semiconductor production. Yttrium oxyfluoride can be a candidate as highly corrosion-resistant material. In this study, three types of dense yttrium oxyfluoride ceramics with different oxygen contents, namely, YOF, Y5O4F7 and Y5O4F7 + YF3, were fabricated by hot pressing, and their mechanical, thermal, and electrical properties were evaluated. Y5O4F7 ceramics showed an excellent thermal stability up to 800 °C, a low loss factor, and volume resistivity comparable to conventional plasma-resistant oxides, such as Y2O3. From these results, yttrium oxyfluoride ceramics are strongly suggested to be used as electrostatic chucks in semiconductor production.

  2. ADSORPTION OF CERIUM VALUES FROM AQUEOUS SOLUTIONS

    DOEpatents

    Roberts, F.P.

    1963-08-13

    Cerium can be removed from aqueous nitric acid (2 to 13 M) solutions by passing the latter over a PbO/sub 2/-containing anion exchange resin. The cerium is taken up by the resin, while any lanthanides, yttrium, and strontium present remain in the solution. (AEC)

  3. Comparison of the wear and flexural characteristics of flowable resin composites for posterior lesions.

    PubMed

    Sumino, Natsu; Tsubota, Keishi; Takamizawa, Toshiki; Shiratsuchi, Koji; Miyazaki, Masashi; Latta, Mark A

    2013-01-01

    To determine the localized wear and flexural properties of flowable resin composites for posterior lesions compared with universal resin composites produced by the same manufacturers. Ten specimens of each of three flowable resins, G-ænial Universal Flo, G-ænial Flo and Clearfil Majesty Flow, and the corresponding resin composite materials, Kalore and Clearfil Majesty Esthetics, were prepared in custom fixtures and subjected to 400,000 wear machine cycles to simulate localized wear. The total maximum depth and volume loss of the wear facets was calculated for each specimen using a profilometer. A three-point bending test was performed to determine the flexural strength, modulus of elasticity and resilience. Values were statistically compared using one-way analysis of variance (ANOVA) followed by Tukey's Honestly Significant Difference (HSD) test. The wear depth ranged from 58.3-126.9 m and the volumetric loss ranged from 0.019-0.049 mm(3), with significant differences observed between restorative materials. The wear depth of G-ænial Universal Flo was significantly smaller than those of the other resin composites tested. The flexural strengths and elastic modulus ranged from 90.5-135.1 MPa and from 4.7-7.6 GPa, respectively. A significantly greater flexural strength and higher elastic modulus was found for G-ænial Universal Flo than the other composites. The wear and mechanical properties of the flowable resin composites tested suggested improved performance compared with universal resin composites.

  4. Graphite fiber reinforced thermoplastic resins

    NASA Technical Reports Server (NTRS)

    Novak, R. C.

    1975-01-01

    Mechanical properties of neat resin samples and graphite fiber reinforced samples of thermoplastic resins were characterized with particular emphasis directed to the effects of environmental exposure (humidity, temperature and ultraviolet radiation). Tensile, flexural, interlaminar shear, creep and impact strengths were measured for polysulfone, polyarylsulfone and a state-of-the-art epoxy resin samples. In general, the thermoplastic resins exhibited environmental degradation resistance equal to or superior to the reference epoxy resin. Demonstration of the utility and quality of a graphite/thermoplastic resin system was accomplished by successfully thermoforming a simulated compressor blade and a fan exit guide vane.

  5. Method for rapid screening analysis of Sr-90 in edible plant samples collected near Fukushima, Japan.

    PubMed

    Amano, Hikaru; Sakamoto, Hideaki; Shiga, Norikatsu; Suzuki, Kaori

    2016-06-01

    A screening method for measuring (90)Sr in edible plant samples by focusing on (90)Y in equilibrium with (90)Sr is reported. (90)Y was extracted from samples with acid, co-precipitated with iron hydroxide, and precipitated with oxalic acid. The dissolved oxalate precipitate was loaded on an extraction chromatography resin, and the (90)Y-enriched eluate was analyzed by Cherenkov counting with a TDCR liquid scintillation counter. (90)Sr ((90)Y) concentration was determined in plant samples collected near the damaged Fukushima Daiichi Nuclear Power Plants with this method. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Optical and color stabilities of paint-on resins for shade modification of restorative resins.

    PubMed

    Arikawa, Hiroyuki; Kanie, Takahito; Fujii, Koichi; Ban, Seiji; Homma, Tetsuya; Takahashi, Hideo

    2004-06-01

    The purpose of this study was to examine the optical and color stabilities of the paint-on resin used for shade modification of restorative resins. Three shades of paint-on resin and two crown and bridge resins were used. The light transmittance characteristics of the materials during accelerated aging tests such as water immersion, toothbrush abrasion, ultraviolet (UV) light irradiation, and staining tests were measured. Discolorations of materials resulting from tests were also determined. There were no significant effects of water immersion, toothbrush abrasion and UV light irradiation on the light transmittance and visible color change of paint-on resins, whereas the staining tests significantly decreased the light transmittance and increased color change of the translucent shades of materials. Our results indicate that the paint-on resins exhibit stable optical properties and color appearance, which are at least as good as the crown and bridge resins.

  7. Mechanical testing of a steel-reinforced epoxy resin bar and clamp for external skeletal fixation of long-bone fractures in cats.

    PubMed

    Leitch, B J; Worth, A J

    2018-05-01

    To provide veterinarians with confidence when using a commercially available epoxy resin in external skeletal fixators (ESF), testing was conducted to determine exothermia during curing of the epoxy resin compared to polymethylmethacrylate (PMMA), the hardness of the epoxy resin as a bar over 16 weeks, and the strength of the epoxy resin bar compared with metal clamps in similarly constructed Type 1a ESF constructs simulating the repair of feline long bone fractures. Exothermia of the epoxy resin during curing was tested against PMMA with surface temperatures recorded over the first 15 minutes of curing, using four samples of each product. The hardness of 90 identical epoxy resin bars was tested by subjecting them to cyclic loads (1,000 cycles of 20.5 N, every 7 days) over a 16-week period and impact testing 10 bars every 2 weeks. Ten bars that were not subjected to cyclic loads were impact tested at 0 weeks and another 10 at 16 weeks. Strength of the epoxy resin product, as a bar and clamp composite, was tested against metal SK and Kirschner-Ehmer (KE) clamps and bars in Type 1a, tied-in intramedullary pin, ESF constructs with either 90° or 75° pin placement, subjected to compressive and bending loads to 75 N. The maximum temperature during curing of the epoxy resin (min 39.8, max 43.0)°C was less than the PMMA (min 85.2, max 98.5)°C (p<0.001). There was no change in hardness of the epoxy resin bars over the 16 weeks of cyclic loading (p=0.58). There were no differences between the median strength of the epoxy resin, SK or KE ESF constructs in compression or bending when tested to 75 N (p>0.05). Stiffness of constructs with 75° pin placement was greater for SK than epoxy resin constructs in compression (p=0.046), and was greater for KE than epoxy resin constructs in bending (p=0.033). The epoxy resin tested was found to be less exothermic than PMMA; bars made from the epoxy resin showed durability over an expected fracture healing timeframe and had

  8. Bio-active glass air-abrasion has the potential to remove resin composite restorative material selectively

    NASA Astrophysics Data System (ADS)

    Milly, Hussam; Andiappan, Manoharan; Thompson, Ian; Banerjee, Avijit

    2014-06-01

    The aims of this study were to assess: (a) the chemistry, morphology and bioactivity of bio-active glass (BAG) air-abrasive powder, (b) the effect of three air-abrasion operating parameters: air pressure, powder flow rate (PFR) and the abrasive powder itself, on the selective removal of resin composite and (c) the required "time taken". BAG abrasive particles were characterised using scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDX) and Fourier-transform infrared spectroscopy (FTIR). Standardised resin composite restorations created within an enamel analogue block (Macor™) in vitro, were removed using air-abrasion undersimulated clinical conditions. 90 standardised cavities were scanned before and after resin composite removal using laser profilometry and the volume of the resulting 3D images calculated. Multilevel linear model was used to identify the significant factors affecting Macor™ removal. BAG powder removed resin composite more selectively than conventional air-abrasion alumina powder using the same operating parameters (p < 0.001) and the effect of altering the unit's operating parameters was significant (p < 0.001). In conclusion, BAG powder is more efficient than alumina in the selective removal of resin composite particularly under specific operating parameters, and therefore may be recommended clinically as a method of preserving sound enamel structure when repairing and removing defective resin composite restorations.

  9. Effect of indirect composite treatment microtensile bond strength of self-adhesive resin cements

    PubMed Central

    Escribano, Nuria; Baracco, Bruno; Romero, Martin; Ceballos, Laura

    2016-01-01

    Background No specific indications about the pre-treatment of indirect composite restorations is provided by the manufacturers of most self-adhesive resin cements. The potential effect of silane treatment to the bond strength of the complete tooth/indirect restoration complex is not available.The aim of this study was to determine the contribution of different surface treatments on microtensile bond strength of composite overlays to dentin using several self-adhesive resin cements and a total-etch one. Material and Methods Composite overlays were fabricated and bonding surfaces were airborne-particle abraded and randomly assigned to two different surface treatments: no treatment or silane application (RelyX Ceramic Primer) followed by an adhesive (Adper Scotchbond 1 XT). Composite overlays were luted to flat dentin surfaces using the following self-adhesive resin cements: RelyX Unicem, G-Cem, Speedcem, Maxcem Elite or Smartcem2, and the total-etch resin cement RelyX ARC. After 24 h, bonded specimens were cut into sticks 1 mm thick and stressed in tension until failure. Two-way ANOVA and SNK tests were applied at α=0.05. Results Bond strength values were significantly influenced by the resin cement used (p<0.001). However, composite surface treatment and the interaction between the resin cement applied and surface treatment did not significantly affect dentin bond strength (p>0.05). All self-adhesive resin cements showed lower bond strength values than the total-etch RelyX ARC. Among self-adhesive resin cements, RelyX Unicem and G-Cem attained statistically higher bond strength values. Smartcem2 and Maxcem Elite exhibited 80-90% of pre-test failures. Conclusions The silane and adhesive application after indirect resin composite sandblasting did not improve the bond strength of dentin-composite overlay complex. Selection of the resin cement seems to be a more relevant factor when bonding indirect composites to dentin than its surface treatment. Key words

  10. Process for strontium-82 separation

    DOEpatents

    Heaton, Richard C.; Jamriska, Sr., David J.; Taylor, Wayne A.

    1992-01-01

    A process for selective separation of strontium-82 and strontium-85 from proton irradiated molybdenum targets comprises dissolving the molybdenum target in a hydrogen peroxide solution to form a first solution containing ions selected from a group consisting of molybdenum, niobium, technetium, selenium, vanadium, arsenic, germanium, zirconium, rubidium, zinc, beryllium, cobalt, iron, manganese, chromium, strontium, and yttrium; passing the solution through a first cationic resin whereby ions selected from a group consisting of zinc, beryllium, cobalt, iron, manganese, chromium, strontium, yttrium a portion of zirconium and a portion of rubidium are selectively absorbed by the first resin; contacting the first resin with an acid solution to strip and remove the absorbed ions from the first cationic exchange resin to form a second solution; evaporating the second solution for a time sufficient to remove substantially all of the acid and water from the solution whereby a residue remains; dissolving the residue in a dilute acid to form a third solution; passing the third solution through a second cationic resin whereby the ions are absorbed by the second resin; contacting the second resin with a dilute sulfuric acid solution whereby the absorbed ions selected from the group consisting of rubidium, zinc, beryllium, cobalt, iron, manganese, chromium and zirconium are selectively removed from the second resin; and contacting the second resin with a dilute acid solution whereby the absorbed strontium ions are selectively removed.

  11. Hydrothermal synthesis, crystal structures and photoluminescence properties of mixed europium-yttrium organic frameworks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han Yinfeng; Department of Chemistry and Environmental Science, Taishan University, Taian 271021; Fu Lianshe

    Three mixed europium-yttrium organic frameworks: Eu{sub 2-x}Y{sub x}(Mel)(H{sub 2}O){sub 6} (Mel=mellitic acid or benzene-1,2,3,4,5,6-hexacarboxylic acid, x=0.38 1, 0.74 2, and 0.86 3) have been synthesized and characterized. All the compounds contain a 3-D net with (4, 8)-flu topology. The study indicates that the photoluminescence properties are effectively affected by the different ratios of europium and yttrium ions, the quantum efficiency is increased and the Eu{sup 3+} lifetime becomes longer in these MOFs than those of the Eu analog. - Graphical abstract: Three mixed europium and yttrium organic frameworks: Eu{sub 2-x}Y{sub x}(Mel)(H{sub 2}O){sub 6} (Mel=mellitic acid) have been synthesized and characterized.more » All the compounds contain a 3-D net with (4, 8)-flu topology. The study indicates that the photoluminescence properties are effectively affected by the different ratios of europium and yttrium ions, the quantum efficiency is increased and the Eu{sup 3+} lifetime becomes longer in these MOFs than those of the Eu analog. Highlights: Black-Right-Pointing-Pointer Three (4, 8)-flu topological mixed Eu and Y MOFs were synthesized under mild conditions. Black-Right-Pointing-Pointer Metal ratios were refined by the single crystal data consistent with the EDS analysis. Black-Right-Pointing-Pointer Mixed Eu and Y MOFs show longer lifetime and higher quantum efficiency than the Eu analog. Black-Right-Pointing-Pointer Adding inert lanthanide into luminescent MOFs enlarges the field of luminescent MOFs.« less

  12. Tooth brush abrasion of paint-on resins for shade modification of crown and bridge resins.

    PubMed

    Fujii, Koichi; Ban, Seiji; McCabe, John F

    2003-09-01

    The purpose of this study was to evaluate the surface roughness and resistance to toothbrush abrasion of three experimental paint-on composite resins developed for the shade modification of crown and bridge resins. The paint-on resins had less filler volume fraction than restorative composites or the crown and bridge resins and consequently were of low viscosity. The maximum surface roughness (Rmax) and the maximum depth loss by abrasion for the paint-on resins following 40,000 cycles of brushing ranged from 2.45 to 4.07 microm and 8.63 to 13.67 microm, respectively. Rmax values were 37.7-67.5% lower than that for the crown and bridge resin subjected to the same test. Wear depth was 19.9-49.4% lower than for the crown and bridge resin. These results suggest that the paint-on resins are expected to have adequate resistance to toothbrush abrasion and may therefore be suitable for clinical use.

  13. Polyester Resin Hazards

    PubMed Central

    Bourne, L. B.; Milner, F. J. M.

    1963-01-01

    Polyester resins are being increasingly used in industry. These resins require the addition of catalysts and accelerators. The handling of polyester resin system materials may give rise to skin irritations, allergic reactions, and burns. The burns are probably due to styrene and organic peroxides. Atmospheric pollution from styrene and explosion and fire risks from organic peroxides must be prevented. Where dimethylaniline is used scrupulous cleanliness and no-touch technique must be enforced. Handling precautions are suggested. Images PMID:14014495

  14. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: implications for planning 90Y radioembolization?

    PubMed

    Burgmans, M C; Too, C W; Kao, Y H; Goh, A S W; Chow, P K H; Tan, B S; Tay, K H; Lo, R H G

    2012-12-01

    To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. From August 2008 to November 2010, 79 patients (range 23-83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p<0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. Demonstrating the potential of yttrium-doped barium zirconate electrolyte for high-performance fuel cells.

    PubMed

    Bae, Kiho; Jang, Dong Young; Choi, Hyung Jong; Kim, Donghwan; Hong, Jongsup; Kim, Byung-Kook; Lee, Jong-Ho; Son, Ji-Won; Shim, Joon Hyung

    2017-02-23

    In reducing the high operating temperatures (≥800 °C) of solid-oxide fuel cells, use of protonic ceramics as an alternative electrolyte material is attractive due to their high conductivity and low activation energy in a low-temperature regime (≤600 °C). Among many protonic ceramics, yttrium-doped barium zirconate has attracted attention due to its excellent chemical stability, which is the main issue in protonic-ceramic fuel cells. However, poor sinterability of yttrium-doped barium zirconate discourages its fabrication as a thin-film electrolyte and integration on porous anode supports, both of which are essential to achieve high performance. Here we fabricate a protonic-ceramic fuel cell using a thin-film-deposited yttrium-doped barium zirconate electrolyte with no impeding grain boundaries owing to the columnar structure tightly integrated with nanogranular cathode and nanoporous anode supports, which to the best of our knowledge exhibits a record high-power output of up to an order of magnitude higher than those of other reported barium zirconate-based fuel cells.

  16. Thermal cycling effects on adhesion of resin-bovine enamel junction among different composite resins.

    PubMed

    Chen, Wen-Cheng; Ko, Chia-Ling; Wu, Hui-Yu; Lai, Pei-Ling; Shih, Chi-Jen

    2014-10-01

    Thermal cycling is used to mimic the changes in oral cavity temperature experienced by composite resins when used clinically. The purpose of this study is to assess the thermal cycling effects of in-house produced composite resin on bonding strength. The dicalcium phosphate anhydrous filler surfaces are modified using nanocrystals and silanization (w/NP/Si). The resin is compared with commercially available composite resins Filtek Z250, Z350, and glass ionomer restorative material GIC Fuji-II LC (control). Different composite resins were filled into the dental enamel of bovine teeth. The bond force and resin-enamel junction graphical structures of the samples were determined after thermal cycling between 5 and 55°C in deionized water for 600 cycles. After thermal cycling, the w/NP/Si 30wt%, 50wt% and Filtek Z250, Z350 groups showed higher shear forces than glass ionomer GIC, and w/NP/Si 50wt% had the highest shear force. Through SEM observations, more of the fillings with w/NP/Si 30wt% and w/NP/Si 50wt% groups flowed into the enamel tubule, forming closed tubules with the composite resins. The push-out force is proportional to the resin flow depth and uniformity. The push-out tubule pore and resin shear pattern is the most uniform and consistent in the w/NP/Si 50wt% group. Accordingly, this developed composite resin maintains great mechanical properties after thermal cycling. Thus, it has the potential to be used in a clinical setting when restoring non-carious cervical lesions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Imide modified epoxy matrix resins

    NASA Technical Reports Server (NTRS)

    Scola, D. A.; Pater, R. H.

    1981-01-01

    High char yield epoxy using novel bisimide amines (BIA's) as curing agents with a state of the art epoxy resin was developed. Stoichiometric quantities of the epoxy resin and the BIA's were studied to determine the cure cycle required for preparation of resin specimens. The bisimide cured epoxies were designated IME's (imide modified epoxy). The physical, thermal and mechanical properties of these novel resins were determined. The levels of moisture absorption exhibited by the bisimide amine cured expoxies (IME's) were considerably lower than the state of the art epoxies. The strain-to-failure of the control resin system was improved 25% by replacement of DDS with 6F-DDS. Each BIA containing resin exhibited twice the char yield of the control resin MY 720/DDS. Graphite fiber reinforced control (C) and IME resins were fabricated and characterized. Two of the composite systems showed superior properties compared to the other Celion 6000/IME composite systems and state of the art graphite epoxy systems. The two systems exhibited excellent wet shear and flexural strengths and moduli at 300 and 350 F.

  18. Effects of air-polishing powders on color stability of composite resins.

    PubMed

    Güler, Ahmet Umut; Duran, Ibrahim; Yücel, Ali Çağin; Ozkan, Pelin

    2011-10-01

    The purpose of this study was to investigate the effect of different air-polishing powders on the color stability of different types of composite resin restorative materials. Thirty cylindrical specimens (15×2 mm) were prepared for each of 7 composite resin restorative materials. All specimens were polished with a series of aluminum oxide polishing discs (Sof-Lex). The prepared specimens of each composite resin were randomly divided into 3 groups of 10 specimens each, for control (Group-C) and two air-powder applications (Group-CP: Cavitron Prophy-Jet; Group-PS: Sirona ProSmile prophylaxis powder). A standard air-polishing unit (ProSmile Handly) was used. All specimens were air-powdered for 10 s at 4-bar pressure. The distance of the spray nosel from the specimens was approximately 10 mm and angulation of the nosel was 90°. Specimens were stored in 100 mL of coffee (Nescafe Classic) for 24 h at 37°C. Color measurement of all specimens was recorded before and after exposure to staining agent with a colorimeter (Minolta CR-300). Color differences (∆E*) between the 2 color measurements (baseline and after 24 h storage) were calculated. The data were analyzed with a 2-way ANOVA test, and mean values were compared by the Tukey HSD test (p<0.05). According to the 2-way ANOVA results, composite resin restorative materials, air-polishing powders, and their interaction were statistically significant (p<0.05) For Aelite Aesthetic Enemal, Filtek Z250, Grandio, CeramX Mono, and Quixfil composite resin restorative materials, no significant difference was observed between Group-PS and Group-CP (p>.05) and these groups demonstrated the highest ∆E* values. For Filtek Silorane and IntenS, the highest ∆E* values were observed in Group-PS. The lowest ∆E* values for all composite resin groups were observed in Group-C. When comparing the 7 composite resin restorative materials, Aelite Aesthetic Enemal demonstrated significantly less ∆E* values than the other composite

  19. Effects of air-polishing powders on color stability of composite resins

    PubMed Central

    GÜLER, Ahmet Umut; DURAN, Ibrahim; YÜCEL, Ali Çagin; ÖZKAN, Pelin

    2011-01-01

    Objectives The purpose of this study was to investigate the effect of different air-polishing powders on the color stability of different types of composite resin restorative materials. Material and methods Thirty cylindrical specimens (15×2 mm) were prepared for each of 7 composite resin restorative materials. All specimens were polished with a series of aluminum oxide polishing discs (Sof-Lex). The prepared specimens of each composite resin were randomly divided into 3 groups of 10 specimens each, for control (Group-C) and two air-powder applications (Group-CP: Cavitron Prophy-Jet; Group-PS: Sirona ProSmile prophylaxis powder). A standard air-polishing unit (ProSmile Handly) was used. All specimens were air-powdered for 10 s at 4-bar pressure. The distance of the spray nosel from the specimens was approximately 10 mm and angulation of the nosel was 90º. Specimens were stored in 100 mL of coffee (Nescafe Classic) for 24 h at 37ºC. Color measurement of all specimens was recorded before and after exposure to staining agent with a colorimeter (Minolta CR-300). Color differences (∆E*) between the 2 color measurements (baseline and after 24 h storage) were calculated. The data were analyzed with a 2-way ANOVA test, and mean values were compared by the Tukey HSD test (p≤0.05). Results According to the 2-way ANOVA results, composite resin restorative materials, air-polishing powders, and their interaction were statistically significant (p<0.05) For Aelite Aesthetic Enemal, Filtek Z250, Grandio, CeramX Mono, and Quixfil composite resin restorative materials, no significant difference was observed between Group-PS and Group-CP (p>.05) and these groups demonstrated the highest ∆E* values. For Filtek Silorane and IntenS, the highest ∆E* values were observed in Group-PS. The lowest ∆E* values for all composite resin groups were observed in Group-C. When comparing the 7 composite resin restorative materials, Aelite Aesthetic Enemal demonstrated significantly less

  20. Hepatic radioembolization with yttrium-90 containing glass microspheres: Preliminary results and clinical follow-up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, J.C.; Walker, S.C.; Ackermann, R.J.

    1994-10-01

    The treatment of hepatic tumors remains unsatisfactory. These lesions receive most of their blood supply from the hepatic artery, therefore the hepatic artery administration of beta-emitting particulate radiopharmaceuticals is an attractive approach to deliver therapeutic irradiation to the liver and differentially to tumors within the liver. A Phase 1 dose escalation study of the hepatic tolerance to radiation delivered by {sup 90}Y containing glass microspheres was carried out in 24 patients with hepatic malignancy. Doses of {sup 90}Y microspheres to achieve an estimated whole-liver nominal absorbed radiation dose of 5000 cGy (two patients), 7500cGy (six patients), 10,000 cGy (seven patients),more » 12,500 cGy (six patients), and 15,000 cGy (three patients) were administered via the hepatic artery. The administered nominal absorbed radiation dose (NARD) was estimated based on liver volume determined from CT scans and the assumption of uniform distribution of microspheres throughout the liver. No hematologic, hepatic or pulmonary toxicity was encountered in the dose range examined during a mean follow-up period of up to 53 mo. Reversible gastritis or duodenitis was encountered in four patients without imaging or biopsy evidence for extra-hepatic deposition of microspheres. Response data, based on CT scans obtained 16 wk after treatment, showed progressive disease in eight patients, stable disease in seven patients, minimal response in four patients and partial response in five patients. Subsequent follow-up revealed three long-term survivors at 204, 216 and 228 wk. These preliminary data demonstrates that in the examined dose range, radiation may be safely delivered to liver tumors by means of {sup 90}Y glass microspheres with encouraging response data. 39 refs., 3 figs., 1 tab.« less

  1. Acetylene terminated matrix resins

    NASA Technical Reports Server (NTRS)

    Goldfarb, I. J.; Lee, Y. C.; Arnold, F. E.; Helminiak, T. E.

    1985-01-01

    The synthesis of resins with terminal acetylene groups has provided a promising technology to yield high performance structural materials. Because these resins cure through an addition reaction, no volatile by-products are produced during the processing. The cured products have high thermal stability and good properties retention after exposure to humidity. Resins with a wide variety of different chemical structures between the terminal acetylene groups are synthesized and their mechanical properties studied. The ability of the acetylene cured polymers to give good mechanical properties is demonstrated by the resins with quinoxaline structures. Processibility of these resins can be manipulated by varying the chain length between the acetylene groups or by blending in different amounts of reactive deluents. Processing conditions similar to the state-of-the-art epoxy can be attained by using backbone structures like ether-sulfone or bis-phenol-A. The wide range of mechanical properties and processing conditions attainable by this class of resins should allow them to be used in a wide variety of applications.

  2. Effect of yttrium on martensite-austenite phase transformation temperatures and high temperature oxidation kinetics of Ti-Ni-Hf high-temperature shape memory alloys

    NASA Astrophysics Data System (ADS)

    Kim, Jeoung Han; Kim, Kyong Min; Yeom, Jong Taek; Young, Sung

    2016-03-01

    The effect of yttrium (< 5.5 at%) on the martensite-austenite phase transformation temperatures, microstructural evolution, and hot workability of Ti-Ni-Hf high-temperature shape memory alloys is investigated. For these purposes, differential scanning calorimetry, hot compression, and thermo-gravimetric tests are conducted. The phase transformation temperatures are not noticeably influenced by the addition of yttrium up to 4.5 at%. Furthermore, the hot workability is not significantly affected by the yttrium addition up to 1.0 at%. However, when the amount of yttrium addition exceeds 1.0 at%, the hot workability deteriorates significantly. In contrast, remarkable improvement in the high temperature oxidation resistance due to the yttrium addition is demonstrated. The total thickness of the oxide layers is substantially thinner in the Y-added specimen. In particular, the thickness of (Ti,Hf) oxide layer is reduced from 200 µm to 120 µm by the addition of 0.3 at% Y.

  3. 21 CFR 175.380 - Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-isopropylidenediphenol-epichlorohydrin epoxy resins. 175.380 Section 175.380 Food and Drugs FOOD AND DRUG ADMINISTRATION... Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins. The...′-isopropylidenediphenol-epichlorohydrin epoxy resins, to which may have been added certain optional adjuvant substances...

  4. 21 CFR 175.380 - Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-isopropylidenediphenol-epichlorohydrin epoxy resins. 175.380 Section 175.380 Food and Drugs FOOD AND DRUG ADMINISTRATION... Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins. The...′-isopropylidenediphenol-epichlorohydrin epoxy resins, to which may have been added certain optional adjuvant substances...

  5. 21 CFR 175.380 - Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...-isopropylidenediphenol-epichlorohydrin epoxy resins. 175.380 Section 175.380 Food and Drugs FOOD AND DRUG ADMINISTRATION... Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins. The...′-isopropylidenediphenol-epichlorohydrin epoxy resins, to which may have been added certain optional adjuvant substances...

  6. 21 CFR 175.380 - Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...-isopropylidenediphenol-epichlorohydrin epoxy resins. 175.380 Section 175.380 Food and Drugs FOOD AND DRUG ADMINISTRATION... Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins. The...′-isopropylidenediphenol-epichlorohydrin epoxy resins, to which may have been added certain optional adjuvant substances...

  7. Two-year interfacial bond durability and nanoleakage of repaired silorane-based resin composite.

    PubMed

    Mobarak, E; El-Deeb, H

    2013-01-01

    To investigate the effect of silane primer application, intermediate adhesive agent/repair composite, and storage period on the interfacial microtensile bond strength (μTBS) of repaired silorane-based resin composite compared with unrepaired composites and on the nanoleakage. Forty-eight 1-month-old substrate specimens from Filtek P90 were roughened, etched, and distributed over two groups (n=24) based on receiving silane (Clearfil Ceramic Primer) or not. Then, half of the specimens (n=12) were repaired with P90 System Adhesive/Filtek P90 and the other half with Adper Scotchbond Multipurpose adhesive/Filtek Z250 resin composite. Within each repair category, repaired specimens were stored in artificial saliva at 37°C for either 24 hours (n=6) or two years before being serially sectioned into sticks (0.6 ± 0.01 mm(2)). From each specimen, two sticks were prepared for nanoleakage determination and four sticks were used for μTBS testing. Additional unrepaired specimens from each composite (n=12) were made to determine the cohesive strength at 24 hours and two years. Mean μTBS were calculated and statistically analyzed. Modes of failure were also determined. General linear model analysis revealed no significant effect for the silane priming, intermediate adhesive agent/repair composite, and storage period or for their interactions on the μTBS values of the repaired specimens. There was no significant difference between the cohesive strength of Filtek P90 and Filtek Z250; both were significantly higher than all repaired categories. At 24 hours, nanoleakage was not detected when silorane-based composite was repaired with the same material. However, after two years, all repair categories showed nanoleakage. Silane application has no effect on μTBS and nanoleakage. Durability of the interfacial bond of repaired silorane-based resin composite appeared successful regardless of the chemistry of the intermediate adhesive agent/composite used for repair. However

  8. Color Stability of Heat-cure Acrylic Resin Subjected to Simulated Short-term Immersion in Fast-acting Denture Cleansers.

    PubMed

    Lohitha, K; Prakash, M; Gopinadh, A; Sai Sankar, A J; Sandeep, C H; Sreedevi, B

    2016-01-01

    Regular usage of denture cleansers is recommended in complete denture wearers for effective plaque control, and these cleansers alter the physical properties of acrylic resin over a period of time. Thus, an in vitro study was carried out to assess the effect of denture cleansers on the color stability of heat-cure denture base resin. The aim of the present study was to evaluate the effect of commercially available fast-acting denture cleansers on the color stability of heat-cure denture base resin at different time intervals. Thirty-six heat-cure acrylic resin (Ivoclar Triplex Hot-V) specimens are randomly allocated into four groups - Group A (distilled water as control); Group B (polident - 3 min); Group C (fixodent scope plus); and Group D (stain away plus) comprising of nine samples each. After recording the baseline values, the specimens were immersed in their respective cleansing solutions for a prescribed time interval. This procedure was repeated daily, and the color change (ΔE) was evaluated after 90 and 180 days interval using a colorimeter in a standard "Commission International de l'Eclairage" color system. Paired t -test and Dunnett's T3 test. All the groups exhibited a variable color change (ΔE) for an immersion period of 90 days. However, significant color differences ( P = 0.001) were noticed among the test groups after 180 days. The color change of denture base resin was greater for Group D followed by Groups B, C, and A respectively after 180 days of immersion. The ΔE values of all test groups increased with time.

  9. Method for removing contaminants from plastic resin

    DOEpatents

    Bohnert, George W [Harrisonville, MO; Hand, Thomas E [Lee's Summit, MO; DeLaurentiis, Gary M [Jamestown, CA

    2008-12-09

    A resin recycling method that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The method includes receiving the resin in container form. The containers are then ground into resin particles. The particles are exposed to a solvent, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. After separating the particles and the resin, a solvent removing agent is used to remove any residual solvent remaining on the resin particles after separation.

  10. Optical coherence tomography applied to the evaluation of wear of composite resin for posterior teeth

    NASA Astrophysics Data System (ADS)

    Mota, Cláudia C. B. O.; Guerra, Bruna A.; Machado, Brena S. A.; Cabral, Adolfo J.; Gomes, Anderson S. L.

    2015-06-01

    Resin composites are widely used as restorative materials due to their excellent aesthetical and mechanical properties. Posterior teeth are constantly submitted to occlusal stress and upon restoration require more resistant resins. The aim of this study was to analyze in vitro the wear suffered over time by restorations in resin composite in posterior teeth, by Optical Coherence Tomography (OCT). 30 molars had occlusal cavities prepared and were randomly divided into three groups (n=10) and restored with resin composite: G1: Filtek P90 (3M/ESPE), G2: Tetric N-Ceram (Ivoclar Vivadent); G3: Filtek P60 (3M/ESPE). Specimens were subjected to initial analysis by OCT (OCP930SR, Thorlabs, axial resolution 6.2 μm) and stereoscopic microscope. Specimens were submitted to thermocycling (500 cycles, 5-55 °C) and subjected to simulated wear through a machine chewing movements (Wear Machine WM001), projecting four years of use. After mechanical cycles, the specimens were submitted to a second evaluation by the OCT and stereoscopic microscopy. As a result, it was observed that 90% of the restorations of both groups had fractures and/or points of stress concentration, considered niches for early dissemination of new fracture lines. It was also found that G1 and G2 had more points of stress concentration, whereas G3 had a higher incidence of fracture lines already propagated. It was concluded that the G3 showed more brittle behavior at the masticatory wear when compared to G1 and G2.

  11. Versatile On-Resin Synthesis of High Mannose Glycosylated Asparagine with Functional Handles

    PubMed Central

    Chen, Rui; Pawlicki, Mark A.; Tolbert, Thomas J.

    2013-01-01

    Here we present a synthetic route for solid phase synthesis of N-linked glycoconjugates containing high mannose oligosaccharides which allows the incorporation of useful functional handles on the N-terminus of asparagine. In this strategy, the C-terminus of an Fmoc protected aspartic acid residue is first attached to a solid phase support. The side chain of aspartic acid is protected by a 2-phenylisopropyl protecting group, which allows selective deprotection for the introduction of glycosylation. By using a convergent on-resin glycosylamine coupling strategy, an N-glycosidic linkage is successfully formed on the free side chain of the resin bound aspartic acid with a large high mannose oligosaccharide, Man8GlcNAc2, to yield N-linked high mannose glycosylated asparagine. The use of on-resin glycosylamine coupling provides excellent glycosylation yield, can be applied to couple other types of oligosaccharides, and also makes it possible to recover excess oligosaccharides conveniently after the on-resin coupling reaction. Useful functional handles including an alkene (p-vinylbenzoic acid), an alkyne (4-pentynoic acid), biotin, and 5-carboxyfluorescein are then conjugated onto the N-terminal amine of asparagine on-resin after the removal of the Fmoc protecting group. In this way, useful functional handles are introduced onto the glycosylated asparagine while maintaining the structural integrity of the reducing end of the oligosaccharide. The asparagine side chain also serves as a linker between the glycan and the functional group and preserves the native presentation of N-linked glycan which may aid in biochemical and structural studies. As an example of a biochemical study using functionalized high mannose glycosylated asparagine, a fluorescence polarization assay has been utilized to study the binding of the lectin Concanavalin A (ConA) using 5-carboxyfluorescein labeled high mannose glycosylated asparagine. PMID:24326091

  12. Optimization Recovery of Yttrium Oxide in Precipitation, Extraction, and Stripping Process

    NASA Astrophysics Data System (ADS)

    Perwira, N. I.; Basuki, K. T.; Biyantoro, D.; Effendy, N.

    2018-04-01

    Yttrium oxide can be used as a dopant control rod of nuclear reactors in YSH material and superconductors. Yttrium oxide is obtained in the Xenotime mineral derived from byproduct of tin mining PT Timah Bangka which contain rare earth elements (REE) dominant Y, Dy, and Gd whose content respectively about 29.53%, 7.76%, and 2.58%. Both usage in the field of nuclear and non-nuclear science and technology is need to pure from the impurities. The presence of impurities in the yttrium oxide may affect the characteristic of the material and the efficiency of its use. Thus it needs to be separated by precipitation and extraction-stripping and calcination in the making of the oxide. However, to obtain higher levels of Yttrium oxide, it is necessary to determine the optimum conditions for its separation. The purpose of this research was to determine the optimum pH of precipitation, determine acid media and concentration optimum in extraction and stripping process and determine the efficiency of the separation of Y from REE concentrate. This research was conducted with pH variation in the precipitation process that pHs were 4 - 8, the difference of acid media for the extraction process, i.e., HNO3, HCl and H2SO4 with each concentration of 0,5 M; 1 M; 1,5 M; and 2 M and for stripping process were HNO3, HCl, and H2SO4 with each concentration of 1 M; 2M; and 3 M. Based on the result, the optimum pH of precipitation process was 6,5, the optimumacid media was HNO3 0,5 M, and for stripping process media was HNO3 3 M. The efficiency of precipitation process at pH 6,5 was 69,53 %, extraction process was 96.39% and stripping process was 4,50%. The separation process from precipitation to extraction had increased the purity and the highest efficiency recovery of Y was in the extraction process and obtained Y2O3 purer compared to the feed with the Y2O3 content of 92.87%.

  13. System for removing contaminants from plastic resin

    DOEpatents

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2010-11-23

    A resin recycling system that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The system includes receiving the resin in container form. A grinder grinds the containers into resin particles. The particles are exposed to a solvent in one or more solvent wash vessels, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. A separator is used to separate the resin particles and the solvent. The resin particles are then placed in solvent removing element where they are exposed to a solvent removing agent which removes any residual solvent remaining on the resin particles after separation.

  14. Effect of pore structure on the removal of clofibric acid by magnetic anion exchange resin.

    PubMed

    Tan, Liang; Shuang, Chendong; Wang, Yunshu; Wang, Jun; Su, Yihong; Li, Aimin

    2018-01-01

    The effect of pore structure of resin on clofibric acid (CA) adsorption behavior was investigated by using magnetic anion exchange resins (ND-1, ND-2, ND-3) with increasing pore diameter by 11.68, 15.37, 24.94 nm. Resin with larger pores showed faster adsorption rates and a higher adsorption capacity because the more opened tunnels provided by larger pores benefit the CA diffusion into the resin matrix. The ion exchange by the electrostatic interactions between Cl-type resin and CA resulted in chloride releasing to the solution, and the ratio of released chloride to CA adsorption amount decreased from 0.90 to 0.65 for ND-1, ND-2 and ND-3, indicating that non-electrostatic interactions obtain a larger proportional part of the adsorption into the pores. Co-existing inorganic anions and organic acids reduced the CA adsorption amounts by the competition effect of electrostatic interaction, whereas resins with more opened pore structures weakened the negative influence on CA adsorption because of the existence of non-electrostatic interactions. 85.2% and 65.1% adsorption amounts decrease are calculated for resin ND-1 and ND-3 by the negative influence of 1 mmol L -1 NaCl. This weaken effect of organic acid is generally depends on its hydrophobicity (Log Kow) for carboxylic acid and its ionization degree (pKb) for sulfonic acid. The resins could be reused with the slightly decreases by 1.9%, 3.2% and 5.4% after 7 cycles of regeneration, respectively for ND-1, ND-2 and ND-3, suggesting the ion exchange resin with larger pores are against its reuse by the brine solution regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Mott insulator-to-metal transition in yttrium-doped CaIrO₃.

    PubMed

    Gunasekera, J; Chen, Y; Kremenak, J W; Miceli, P F; Singh, D K

    2015-02-11

    We report on the study of insulator-to-metal transition in post-perovskite compound CaIrO3. It is discovered that a gradual chemical substitution of calcium by yttrium leads to the onset of strong metallic behavior in this compound. This observation is in stark contrast to BaIrO3, which preserves its Mott insulating behavior despite excess of the charge carriers due to yttrium doping. Magnetic measurements reveal that both compounds tend to exhibit magnetic character irrespective of the chemical substitution of Ca or Ba. We analyze these unusual observations in light of recent researches that suggest that CaIrO3 does not necessarily possess j = 1/2 ground state due to structural distortion. The insulator-to-metal transition in CaIrO3 will spur new researches to explore more exotic ground state, including superconductivity, in post-perovskite Mott insulators.

  16. Durability of resin cement bond to aluminium oxide and zirconia ceramics after air abrasion and laser treatment.

    PubMed

    Foxton, Richard M; Cavalcanti, Andrea N; Nakajima, Masatoshi; Pilecki, Peter; Sherriff, Martyn; Melo, Luciana; Watson, Timothy F

    2011-02-01

    The erbium laser has been introduced for cutting enamel and dentin and may have an application in the surface modification of high-strength aluminum oxide and zirconia ceramics. The aim of this study was to evaluate the durability of the bond of conventional dual-cured resin cements to Procera Al(2)O(3) and zirconium oxide ceramics after surface treatment with air abrasion and erbium laser. One hundred twenty Al(2)O(3) and 120 zirconia specimens measuring 3 × 3 × 0.7 mm(3) were divided equally into three groups, and their surfaces treated as follows: either untreated (controls), air abraded with Al(2)O(3) particles, or erbium-laser-treated at a power setting of 200 mJ. The surface of each specimen was then primed and bonded with one of two dual-cured resin cements (either SCP-100 Ceramic Primer and NAC-100 or Monobond S and Variolink II) using a 1-mm thick Tygon tube mold with a 0.75-mm internal bore diameter. After 24 hours and 6 months of water storage at 37°C, a microshear bond strength test was performed at a crosshead speed of 1 mm/min. Surface morphology was examined using a confocal microscope, and failure modes were observed using an optical microscope. The data were analyzed using the Kaplan-Meier nonparametric survival analysis. In the case of zirconia, air abrasion and Erbium:yttrium-aluminum-garnet (Er:YAG) laser treatment of the ceramic surface resulted in a significant reduction in the bond strengths of both resin cements after 6 months water storage; however, when the zirconia surface was left untreated, the SCP-100/NAC-100 group did not significantly reduce in bond strength. In the case of alumina, no treatment, air abrasion and Er:YAG laser treatment of the surface led to no significant reduction in the bond strengths of the three SCP-100/NAC-100 groups after 6 months water storage, whereas all three Monobond S/Variolink II groups showed a significant reduction. Er:YAG laser treatment of the zirconia surface did not result in a durable resin

  17. Cross-reactivity among epoxy acrylates and bisphenol F epoxy resins in patients with bisphenol A epoxy resin sensitivity.

    PubMed

    Lee, Han N; Pokorny, Christopher D; Law, Sandra; Pratt, Melanie; Sasseville, Denis; Storrs, Frances J

    2002-09-01

    The study's objective was 2-fold: first, to evaluate the potential cross-reactivity between Bis-A epoxy resins and epoxy acrylates and second, to study the cross reactivity between Bis-A epoxy resins and newer Bis-F epoxy resins in patients with allergic contact dermatitis to epoxy resins and had positive patch test to the standard epoxy resin based on bisphenol A. Forty-one patients were patch tested to 23 chemicals including epoxy acrylates, Bis-A epoxy resins, and Bis-F epoxy resins, as well as reactive diluents and nonbisphenol epoxy resins. Questions concerning exposure to epoxy resins, occupational history, and problems with dental work were completed. All patients included in the study had positive reactions to the standard Bis-A epoxy resin. Twenty percent (8 of 41) of the patients reacted to at least one of the epoxy acrylates; the most common reaction was to Bis-GMA. Five of 8 patients who reacted to the epoxy acrylates had dental work, but only one patient had problems from her dental work. Six of 8 patients (75%) who reacted to epoxy resins and epoxy acrylates did not react to aliphatic acrylates. Thirty-two percent (13 of 41) reacted to tosylamide epoxy resin, and none reacted to triglycidyl isocyanurate resin. In addition, all patients (100%) had positive reactions to at least one of the Bis-F epoxy resins that were tested. Most patients with sensitivity to Bis-A epoxy resins do not cross-react with epoxy acrylates. Patients with positive patch test reactions to epoxy acrylates used in dentistry usually do not have symptoms from their dental work. To our knowledge, this is the largest series of patients with sensitivity to the standard Bis-A epoxy resin that have been patch tested with the more recently introduced Bis-F epoxy resins. There is significant cross-reactivity between Bis-A and Bis-F epoxy resins, which can be explained by their structural similarity. Copyright 2002, Elsevier Science (USA). All rights reserved.

  18. Ultra-low Temperature Curable Conductive Silver Adhesive with different Resin Matrix

    NASA Astrophysics Data System (ADS)

    Zhou, Xingli; Wang, Likun; Liao, Qingwei; Yan, Chao; Li, Xing; Qin, Lei

    2018-03-01

    The ultra-low temperature curable conductive silver adhesive with curing temperature less than 100 °C needed urgently for the surface conductive treatment of piezoelectric composite material due to the low thermal resistance of composite material and low adhesion strength of adhesive. An ultra-low temperature curable conductive adhesive with high adhesion strength was obtained for the applications of piezoelectric composite material. The microstructure, conductive properties and adhesive properties with different resin matrix were investigated. The conductive adhesive with AG-80 as the resin matrix has the shorter curing time (20min), lower curing temperature (90°C) and higher adhesion strength (7.6MPa). The resistivity of AG-80 sample has the lower value (2.13 × 10-4Ω·cm) than the 618 sample (4.44 × 10-4Ω·cm).

  19. Reflectance, Optical Properties, and Stability of Molybdenum/Strontium and Molybdenum/Yttrium Multilayer Mirrors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kjornrattanawanich, Benjawan

    2002-09-01

    The motivation of this work is to develop high reflectance normal-incidence multilayer mirrors in the 8-12 nm wavelength region for applications in astronomy and extreme ultraviolet lithography. To achieve this goal, Mo/Sr and Mo/Y multilayers were studied. These multilayers were deposited with a UHV magnetron sputtering system and their reflectances were measured with synchrotron radiation. High normal-incidence reflectances of 23% at 8.8 nm, 40.8% at 9.4 nm, and 48.3% at 10.5 nm were achieved. However, the reflectance of Mo/Sr multilayers decreased rapidly after exposure to air. Attempts to use thin layers of carbon to passivate the surface of Mo/Sr multilayers were unsuccessful. Experimental results on the refractive indexmore » $$\\tilde{n}$$ = 1-δ + iβ of yttrium and molybdenum in the 50-1300 eV energy region are reported in this work. This is the first time ever that values on the refractive index of yttrium are measured in this energy range. The absorption part β was determined through transmittance measurements. The dispersive part δ was calculated by means of the Kramers-Kronig formalism. The newly determined values of the refractive index of molybdenum are in excellent agreement with the published data. Those of yttrium are more accurate and contain fine structures around the yttrium M-absorption edges where Mo/Y multilayers operate. These improved sets of optical data lead to better design and modeling of the optical properties of Mo/Y multilayers. The reflectance quality of Mo/Y multilayers is dependent on their optical and structural properties. To correlate these properties with the multilayer reflectance, x-ray diffraction, Rutherford backscattering spectrometry, and transmission electron microscopy were used to analyze samples. Normal-incidence reflectances of 32.6% at 9.27 nm, 38.4% at 9.48 nm, and 29.6% at 9.46 nm were obtained from three representative Mo/Y multilayers which had about 0%, 25%, and 39% atomic oxygen assimilated in their

  20. Assessment of cross-reactivity of new less sensitizing epoxy resin monomers in epoxy resin-allergic individuals.

    PubMed

    Hagvall, Lina; Niklasson, Ida B; Rudbäck, Johanna; O'Boyle, Niamh M; Niklasson, Eva; Luthman, Kristina; Karlberg, Ann-Therese

    2016-09-01

    Measures to prevent occupational exposure to epoxy resins, including education, medical examination, and voluntary agreements between employers and workers, have not been effective enough to protect against skin sensitization. Therefore, alternatives to the major epoxy resin haptens that have been found to be less sensitizing in the local lymph node assay have been developed. To study the cross-reactivity of two newly designed epoxy resin monomers, with decreased skin-sensitizing potency and good technical properties as compared with diglycidyl ether of bisphenol A (DGEBA), in subjects with known contact allergy to epoxy resin of DGEBA type. Eleven individuals with previous positive patch test reactions to epoxy resin of DGEBA participated in the study. The two alternative epoxy resin monomers were synthesized and patch tested in dilution series in parallel with epoxy resin of DGEBA from the baseline series (containing 92% DGEBA). All participants reacted to epoxy resin of DGEBA on retesting. Three participants reacted to monomer 1. No reactions were seen to monomer 2. The alternative monomers studied showed little or no cross-reactivity with epoxy resin of DGEBA. Decreasing the risk of sensitization by using less sensitizing compounds is important, as contact allergy to epoxy resins is common in spite of thorough preventive measures. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawkins, C.; Dietz, M.; Kaminski, M.

    2016-03-01

    A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial,more » extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.« less

  2. Advanced thermoplastic resins, phase 1

    NASA Technical Reports Server (NTRS)

    Hendricks, C. L.; Hill, S. G.; Falcone, A.; Gerken, N. T.

    1991-01-01

    Eight thermoplastic polyimide resin systems were evaluated as composite matrix materials. Two resins were selected for more extensive mechanical testing and both were versions of LaRC-TPI (Langley Research Center - Thermoplastic Polyimide). One resin was made with LaRC-TPI and contained 2 weight percent of a di(amic acid) dopant as a melt flow aid. The second system was a 1:1 slurry of semicrystalline LaRC-TPI powder in a polyimidesulfone resin diglyme solution. The LaRC-TPI powder melts during processing and increases the melt flow of the resin. Testing included dynamic mechanical analysis, tension and compression testing, and compression-after-impact testing. The test results demonstrated that the LaRC-TPI resins have very good properties compared to other thermoplastics, and that they are promising matrix materials for advanced composite structures.

  3. Nontoxic Resins Advance Aerospace Manufacturing

    NASA Technical Reports Server (NTRS)

    2009-01-01

    The 2008 NASA Commercial Invention of the Year, PETI-330, is a polyimide matrix resin that performs well at high temperatures and is easily processed into composites in a simple, short curing cycle. Invented by scientists at Langley Research Center, PETI-330 is now licensed to Ube Industries, based in Japan with its American headquarters in New York. In addition to being durable and lightweight, the resin is also nontoxic, which makes it safe for workers to handle. PETI-330 was created specifically for heat-resistant composites formed with resin transfer molding and resin infusion, which formerly could only be used with low temperature resin systems.

  4. Removal of both N-nitrosodimethylamine and trihalomethanes precursors in a single treatment using ion exchange resins.

    PubMed

    Beita-Sandí, Wilson; Karanfil, Tanju

    2017-11-01

    Drinking water utilities are relying more than ever on water sources impacted by wastewater effluents. Disinfection/oxidation of these waters during water treatment may lead to the formation of several disinfection by-products, including the probable human carcinogen N-nitrosodimethylamine (NDMA) and the regulated trihalomethanes (THMs). In this study, the potential of ion exchange resins to control both NDMA and THMs precursors in a single treatment is presented. Two ion exchange resins were examined, a cation exchange resin (Plus) to target NDMA precursors and an anion exchange resin (MIEX) for THMs precursors control. We applied the resins, individually and combined, in the treatment of surface and wastewater effluent samples. The treatment with both resins removed simultaneously NDMA (43-85%) and THMs (39-65%) precursors. However, no removal of NDMA precursors was observed in the surface water with low initial NDMA FP (14 ng/L). The removals of NDMA FP and THMs FP with Plus and MIEX resins applied alone were (49-90%) and (41-69%), respectively. These results suggest no interaction between the resins, and thus the feasibility of effectively controlling NDMA and THMs precursors concomitantly. Additionally, the effects of the wastewater impact and the natural attenuation of precursors were studied. The results showed that neither the wastewater content nor the attenuation of the precursor affected the removals of NDMA and THMs precursors. Finally, experiments using a wastewater effluent sample showed that an increase in the calcium concentration resulted in a reduction in the removal of NDMA precursors of about 50%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Optical bistability in erbium-doped yttrium aluminum garnet crystal combined with a laser diode.

    PubMed

    Maeda, Y

    1994-01-10

    Optical bistability was observed in a simple structure of an injection laser diode combined with an erbium-doped yttrium aluminum garnet crystal. Since a hysteresis characteristic exists in the relationship between the wavelength and the injection current of a laser diode, an optical memory function capable of holding the output status is confirmed. In addition, an optical signal inversion was caused by the decrease of transmission of the erbium-doped yttrium aluminum garnet crystal against the red shift (principally mode hopping) of the laser diode. It is suggested that the switching time of this phenomenon is the time necessary for a mode hopping by current injection.

  6. Process for strontium-82 separation

    DOEpatents

    Heaton, R.C.; Jamriska, D.J. Sr.; Taylor, W.A.

    1992-12-01

    A process for selective separation of strontium-82 and strontium-85 from proton irradiated molybdenum targets comprises dissolving the molybdenum target in a hydrogen peroxide solution to form a first solution containing ions selected from a group consisting of molybdenum, niobium, technetium, selenium, vanadium, arsenic, germanium, zirconium, rubidium, zinc, beryllium, cobalt, iron, manganese, chromium, strontium, and yttrium; passing the solution through a first cationic resin whereby ions selected from a group consisting of zinc, beryllium, cobalt, iron, manganese, chromium, strontium, yttrium a portion of zirconium and a portion of rubidium are selectively absorbed by the first resin; contacting the first resin with an acid solution to strip and remove the absorbed ions from the first cationic exchange resin to form a second solution; evaporating the second solution for a time sufficient to remove substantially all of the acid and water from the solution whereby a residue remains; dissolving the residue in a dilute acid to form a third solution; passing the third solution through a second cationic resin whereby the ions are absorbed by the second resin; contacting the second resin with a dilute sulfuric acid solution whereby the absorbed ions selected from the group consisting of rubidium, zinc, beryllium, cobalt, iron, manganese, chromium and zirconium are selectively removed from the second resin; and contacting the second resin with a dilute acid solution whereby the absorbed strontium ions are selectively removed. 1 fig.

  7. Incombustible resin composition

    NASA Technical Reports Server (NTRS)

    Akima, T.

    1982-01-01

    Incombustible resin compositions composed of aromatic compounds were obtained through (1) combustion polymer material and (2) bisphenol A or halogenated bisphenol A and bisphenol A diglycidl ether or halogenated bisphenol A diglycidyl ether. The aromatic compound is an adduct of bifunctional phenols and bifunctional epoxy resins.

  8. 4-META opaque resin--a new resin strongly adhesive to nickel-chromium alloy.

    PubMed

    Tanaka, T; Nagata, K; Takeyama, M; Atsuta, M; Nakabayashi, N; Masuhara, E

    1981-09-01

    1) A new adhesive opaque resin containing a reactive monomer, 4-methacryloxy-ethyl trimellitate anhydride (4-META), was prepared, and its application to thermosetting acrylic resin veneer crowns was studied. 2) The 4-META opaque resin was applied to a variety of nickel-chromium dental alloy specimens which had undergone different treatment, and endurance tests were conducted to evaluate the durability of adhesion. 3) Stable adhesion against water penetration was achieved with metal surfaces first etched with HCl and then oxidized with HNO3. A bond strength of 250 kg/cm2 was maintained even after immersion in water at 37 degrees C for 30 wk or at 80 degrees C for ten wk. Furthermore, this value did not decrease even after the specimens were subjected to 500 thermal cycles. 4) The 4-META opaque resin studied can eliminate the necessity for retention devices on metal castings. 5) The smooth 4-META opaque resin should have no adverse effects on gingivae.

  9. Optical properties of paint-on resins for shade modification of crown and bridge resins--light transmittance characteristics--.

    PubMed

    Arikawa, Hiroyuki; Kanie, Takahito; Fujii, Koichi; Homma, Tetsuya; Takahashi, Hideo; Ban, Seiji

    2003-09-01

    The purpose of this study was to examine the light transmittance characteristics of the paint-on resins for shade modification. Three shades of paint-on resin, one crown and bridge resin, and human enamel were used. Specimens with four different thicknesses (75-150 microm) were prepared. The light transmittances including its wavelength distribution and diffusion characteristics were measured. The color values and the color differences among thicknesses of specimens were also determined. The light transmittance values of the paint-on resins ranged from 60.3% to 88.3% at 100 microm thickness, which were lower or nearly equal in comparison with the crown and bridge resin and enamel. Although differences in the wavelength distribution of transmittance among materials were found at lower wavelengths, all materials showed similar diffusion characteristics. The thin layer of paint-on resin effectively changed the color of restorative resin. The paint-on resin may be an effective material for the modification of the color appearance matching required.

  10. Detoxification of Organosolv-Pretreated Pine Prehydrolysates with Anion Resin and Cysteine for Butanol Fermentation.

    PubMed

    Li, Jing; Shi, Suan; Tu, Maobing; Via, Brain; Sun, Fubao Fuelbio; Adhikari, Sushil

    2018-05-02

    Bioconversion of lignocellulose to biofuels suffers from the degradation compounds formed during pretreatment and acid hydrolysis. In order to achieve an efficient biomass to biofuel conversion, detoxification is often required before enzymatic hydrolysis and microbial fermentation. Prehydrolysates from ethanol organosolv-pretreated pine wood were used as substrates in butanol fermentation in this study. Six detoxification approaches were studied and compared, including overliming, anion exchange resin, nonionic resin, laccase, activated carbon, and cysteine. It was observed that detoxification by anion exchange resin was the most effective method. The final butanol yield after anion exchange resin treatment was comparable to the control group, but the fermentation was delayed for 72 h. The addition of Ca(OH) 2 was found to alleviate this delay and improve the fermentation efficiency. The combination of Ca(OH) 2 and anion exchange resin resulted in completion of fermentation within 72 h and acetone-butanol-ethanol (ABE) production of 11.11 g/L, corresponding to a yield of 0.21 g/g sugar. The cysteine detoxification also resulted in good detoxification performance, but promoted fermentation towards acid production (8.90 g/L). The effect of salt on ABE fermentation was assessed and the possible role of Ca(OH) 2 was to remove the salts in the prehydrolysates by precipitation.

  11. Do nutrition labels influence healthier food choices? Analysis of label viewing behaviour and subsequent food purchases in a labelling intervention trial.

    PubMed

    Ni Mhurchu, Cliona; Eyles, Helen; Jiang, Yannan; Blakely, Tony

    2018-02-01

    There are few objective data on how nutrition labels are used in real-world shopping situations, or how they affect dietary choices and patterns. The Starlight study was a four-week randomised, controlled trial of the effects of three different types of nutrition labels on consumer food purchases: Traffic Light Labels, Health Star Rating labels, or Nutrition Information Panels (control). Smartphone technology allowed participants to scan barcodes of packaged foods and receive randomly allocated labels on their phone screen, and to record their food purchases. The study app therefore provided objectively recorded data on label viewing behaviour and food purchases over a four-week period. A post-hoc analysis of trial data was undertaken to assess frequency of label use, label use by food group, and association between label use and the healthiness of packaged food products purchased. Over the four-week intervention, study participants (n = 1255) viewed nutrition labels for and/or purchased 66,915 barcoded packaged products. Labels were viewed for 23% of all purchased products, with decreasing frequency over time. Shoppers were most likely to view labels for convenience foods, cereals, snack foods, bread and bakery products, and oils. They were least likely to view labels for sugar and honey products, eggs, fish, fruit and vegetables, and meat. Products for which participants viewed the label and subsequently purchased the product during the same shopping episode were significantly healthier than products where labels were viewed but the product was not subsequently purchased: mean difference in nutrient profile score -0.90 (95% CI -1.54 to -0.26). In a secondary analysis of a nutrition labelling intervention trial, there was a significant association between label use and the healthiness of products purchased. Nutrition label use may therefore lead to healthier food purchases. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Probing the carbonyl functionality of a petroleum resin and asphaltene through oximation and schiff base formation in conjunction with N-15 NMR

    USGS Publications Warehouse

    Thorn, Kevin A.; Cox, Larry G.

    2015-01-01

    Despite recent advances in spectroscopic techniques, there is uncertainty regarding the nature of the carbonyl groups in the asphaltene and resin fractions of crude oil, information necessary for an understanding of the physical properties and environmental fate of these materials. Carbonyl and hydroxyl group functionalities are not observed in natural abundance 13C nuclear magnetic resonance (NMR) spectra of asphaltenes and resins and therefore require spin labeling techniques for detection. In this study, the carbonyl functionalities of the resin and asphaltene fractions from a light aliphatic crude oil that is the source of groundwater contamination at the long term USGS study site near Bemidji, Minnesota, have been examined through reaction with 15N-labeled hydroxylamine and aniline in conjunction with analysis by solid and liquid state 15N NMR. Ketone groups were revealed through 15N NMR detection of their oxime and Schiff base derivatives, and esters through their hydroxamic acid derivatives. Anilinohydroquinone adducts provided evidence for quinones. Some possible configurations of the ketone groups in the resin and asphaltene fractions can be inferred from a consideration of the likely reactions that lead to heterocyclic condensation products with aniline and to the Beckmann reaction products from the initially formed oximes. These include aromatic ketones and ketones adjacent to quaternary carbon centers, β-hydroxyketones, β-diketones, and β-ketoesters. In a solid state cross polarization/magic angle spinning (CP/MAS) 15N NMR spectrum recorded on the underivatized asphaltene as a control, carbazole and pyrrole-like nitrogens were the major naturally abundant nitrogens detected.

  13. Probing the Carbonyl Functionality of a Petroleum Resin and Asphaltene through Oximation and Schiff Base Formation in Conjunction with N-15 NMR

    PubMed Central

    Thorn, Kevin A.; Cox, Larry G.

    2015-01-01

    Despite recent advances in spectroscopic techniques, there is uncertainty regarding the nature of the carbonyl groups in the asphaltene and resin fractions of crude oil, information necessary for an understanding of the physical properties and environmental fate of these materials. Carbonyl and hydroxyl group functionalities are not observed in natural abundance 13C nuclear magnetic resonance (NMR) spectra of asphaltenes and resins and therefore require spin labeling techniques for detection. In this study, the carbonyl functionalities of the resin and asphaltene fractions from a light aliphatic crude oil that is the source of groundwater contamination at the long term USGS study site near Bemidji, Minnesota, have been examined through reaction with 15N-labeled hydroxylamine and aniline in conjunction with analysis by solid and liquid state 15N NMR. Ketone groups were revealed through 15N NMR detection of their oxime and Schiff base derivatives, and esters through their hydroxamic acid derivatives. Anilinohydroquinone adducts provided evidence for quinones. Some possible configurations of the ketone groups in the resin and asphaltene fractions can be inferred from a consideration of the likely reactions that lead to heterocyclic condensation products with aniline and to the Beckmann reaction products from the initially formed oximes. These include aromatic ketones and ketones adjacent to quaternary carbon centers, β-hydroxyketones, β-diketones, and β-ketoesters. In a solid state cross polarization/magic angle spinning (CP/MAS) 15N NMR spectrum recorded on the underivatized asphaltene as a control, carbazole and pyrrole-like nitrogens were the major naturally abundant nitrogens detected. PMID:26556054

  14. Study on the Characteristics of a Scintillator for Beta-ray Detection using Epoxy Resin

    NASA Astrophysics Data System (ADS)

    Nam, Jong Soo; Choi, Yong Seok; Hong, Sang Bum; Seo, Bum Kyung; Moon, Jei Kwon; Choi, Jong Won

    2017-09-01

    A thin plate of a plastic scintillator for detecting a beta-ray was developed. The plastic scintillator was made using epoxy resin and organic scintillators such as 2.5-diphenyloxazole (PPO) and 1,4-bis [5-phenyl-2-oxazole] benzene (POPOP). The mixture ratio of epoxy resin and the organic scintillators was determined using their absorbance, transmittance, emission spectra, and transparency. Their optimal weight percentage of PPO and POPOP in the organic scintillators was adjusted to 0.2 wt%:0.01 wt%. The prepared plastic scintillator was used to measure the standard source of Sr-90. The pulse height spectra and total counts of the prepared plastic scintillator were similar to a commercial plastic scintillator. Based on the above results, a large-area plastic scintillator was prepared for rapid investigation of a site contaminated with Sr-90. The prepared large-area plastic scintillator was evaluated for the characteristics in the laboratory. The evaluation results are expected to be usefully utilized in the development of a large-area plastic scintillation detector. The large-area plastic scintillation detector developed on the basis of the evaluation results is expected to be utilized to quickly measure the contamination of Sr-90 in the grounds used as a nuclear power facility.

  15. Action of ionizing radiation on epoxy resins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van de Voorde, M. E.

    1970-12-01

    The resistance of classical and experimental epoxy resins to irradiation was studied. The resistance to irradiation of epoxy resins of diverse compositions as well as the development of resins having a radioresistance that approaches that of certain ceramics are discussed. Sources of irradiation and the techniques of dosimetry used are described. The structures of certain epoxy resins and of hardeners are given. The preparation of these resins and their physical properties is described. The effects of radiation on epoxy resins, as well as conditions of irradiation, and suggested mechanisms for degradation of the irradiated resins are discussed. The relationship betweenmore » chemical structure of the resins and their physical properties is evaluated. (115 references) (JCB)« less

  16. 21 CFR 177.2510 - Polyvinylidene fluoride resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Polyvinylidene fluoride resins. 177.2510 Section... Repeated Use § 177.2510 Polyvinylidene fluoride resins. Polyvinylidene fluoride resins may be safely used... fluoride resins consist of basic resins produced by the polymerization of vinylidene fluoride. (b) The...

  17. Oxygen index tests of thermosetting resins

    NASA Technical Reports Server (NTRS)

    Gilwee, W. J., Jr.; Parker, J. A.; Kourtides, D. A.

    1980-01-01

    The flammability characteristics of nine thermosetting resins under evaluation for use in aircraft interiors are described. These resins were evaluated using the Oxygen Index (ASTM 2863) testing procedure. The test specimens consisted of both neat resin and glass reinforced resin. When testing glass-reinforced samples it was observed that Oxygen Index values varied inversely with resin content. Oxygen values were also obtained on specimens exposed to temperatures up to 300 C. All specimens experienced a decline in Oxygen Index when tested at an elevated temperature.

  18. Dynamic-mechanical and thermomechanical properties of cellulose nanofiber/polyester resin composites.

    PubMed

    Lavoratti, Alessandra; Scienza, Lisete Cristine; Zattera, Ademir José

    2016-01-20

    Composites of unsaturated polyester resin (UPR) and cellulose nanofibers (CNFs) obtained from dry cellulose waste of softwood (Pinus sp.) and hardwood (Eucalyptus sp.) were developed. The fiber properties and the influence of the CNFs in the dynamic-mechanical and thermomechanical properties of the composites were evaluated. CNFs with a diameter of 70-90 nm were obtained. Eucalyptus sp. has higher α-cellulose content than Pinus sp. fibers. The crystallinity of the cellulose pulps decreased after grinding. However, high values were still obtained. The chemical composition of the fibers was not significantly altered by the grinding process. Eucalyptus sp. CNF composites had water absorption close to the neat resin at 1 wt% filler. The dynamic-mechanical properties of Eucalyptus sp. CNFs were slightly increased and the thermal stability was improved. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Comparison of microleakage in Class II cavities restored with silorane-based and methacrylate-based composite resins using different restorative techniques over time.

    PubMed

    Khosravi, Kazem; Mousavinasab, Seyed-Mostafa; Samani, Mahsa Sahraneshin

    2015-01-01

    Despite the growing tendency toward tooth-colored restorations in dentistry, polymerization shrinkage and subsequent marginal microleakage remains a problem. The aim of this in vitro study was to compare microleakage between silorane-based and methacrylate-based composite resins at different time intervals and with different restorative techniques. In this in vitro study, 108 sound extracted human molar teeth were used. Mesial and distal proximal class II boxes with dimensions of 1.5 mm depth and 4 mm width were prepared. The gingival margins of all cavities were 1 mm below the cement enamel junction. The teeth were randomly divided into three groups based on test materials. In the first group, the teeth were restored by a nanocomposite (Filtek Z350XT, 3MESPE) and SE Bond adhesive (Kuraray, Japan), in the second group, the teeth were restored with a silorane-based (Filtek P90, 3MESPE) and Filtek P90 Adhesive (3M ESPE, USA) and in the third group, the teeth were restored with a microhybrid posterior composite resin (Filtek P60, 3MESPE) and SE Bond adhesive (Kuraray, Japan). Half of the proximal cavities in each of these three groups were restored in two horizontal layers and the other half in four horizontal layers. After a period of aging (24-h, 3-month and 6-month) in water and then application of 500 thermal cycles, the teeth were immersed for 24-h in 0.5% fuchsin and evaluated under a stereomicroscope at ×36 magnification to evaluate leakage in gingival margin. Data was statistically analyzed using Kruskal-Wallis and Mann-Whitney U-tests. P ≤ 0.05 was considered as significant. In Z350XT statistically significant differences were observed in microleakage in comparison of 24-h and 6-month intervals (P = 0.01) that was higher in 6-month. Comparison of microleakage in P90 and P60 composite resins was also statistically significant and was less in P90. Microleakage was not significantly different between P90 and Z350XT at 24-h. However, this difference was

  20. Quantitative evaluation of XAD-8 and XAD-4 resins used in tandem for removing organic solutes from water

    USGS Publications Warehouse

    Malcolm, R.L.; MacCarthy, P.

    1992-01-01

    The combined XAD-8 and XAD-4 resin procedure for the isolation of dissolved organic solutes from water was found to isolate 85% or more of the organic solutes from Lake Skjervatjern in Norway. Approximately 65% of the dissolved organic carbon (DOC) was first removed on XAD-8 resin, and then an additional 20% of the DOC was removed on XAD-4 resin. Approximately 15% of the DOC solutes (primarily hydrophilic neutrals) were not sorbed or concentrated by the procedure. Of the 65% of the solutes removed on XAD-8 resin, 40% were fulvic acids, 16% were humic acids, and 9% were hydrophobic neutrals. Approximately 20% of the hydrophilic solutes that pass through the XAD-8 resin were sorbed solutes on the second resin, XAD-4 (i.e., they were hydrophobic relative to the XAD-4 resin). The fraction sorbed on XAD-4 resin was called XAD-4 acids because it represented approximately 85-90% of the hydrophilic XAD-8 acid fraction according to the original XAD-8 fractionation procedure. The recovery of hydrophobic acids (fulvic acids and humic acids) and the hydrophobic neutral fraction from XAD-8 resin was essentially quantitative at 96%, 98%, and 86%, respectively. The recovery of XAD-4 acids from the XAD-4 resin was only about 50%. The exact reason for this moderately low recovery is unknown, but could result from ??-?? bonding between these organic solutes and the aromatic matrix of XAD-4. The hydrophobic/hydrophilic solute separation on XAD-8 resin for water from background Side A and Side B of the lake was almost identical at 65 and 67%, respectively. This result suggested that both sides of the lake are similar in organic chemical composition even though the DOC variation from side to side is 20%.

  1. Phenoxy resins containing pendent ethynyl groups

    NASA Technical Reports Server (NTRS)

    Hergenrother, P. M.; Jensen, B. J.; Havens, S. J.

    1984-01-01

    As part of an effort on tougher/solvent resistant matrix resins for composites, research was directed towards exploring methods to improve the solvent resistance of linear amorphous thermoplastics. Ethyl reactive groups were placed on the ends of oligomers and pendent along the polymer chain and subsequently thermally reacted to provide crosslinking and thus improvement in solvent resistance. This concept is extended to another thermoplastic, a phenoxy resin. A commercially available phenoxy resin (PKHH) was systematically modified by reaction of the pendent hydroxyl groups on the phenoxy resin with various amounts of 4-ethynylbenzoyl chloride. As the pendent ethynyl group content in the phenoxy resin increased, the cured resin exhibited a higher glass transition temperature, better solvent resistance and less flexibility. The solvent resistance was further improved by correcting a low molecular weight diethynyl compound, 2,2-bis(4-ethynylbenzoyloxy-4'-phenyl)propane, with a phenoxy resin containing pendent ethynyl groups.

  2. Pharmaceutical Applications of Ion-Exchange Resins

    NASA Astrophysics Data System (ADS)

    Elder, David P.

    2005-04-01

    The historical uses of ion-exchange resins and a summary of the basic chemical principles involved in the ion-exchange process are discussed. Specific applications of ion-exchange resins are provided. The utility of these agents to stabilize drugs are evaluated. Commonly occurring chemical and physical incompatibilities are reviewed. Ion-exchange resins have found applicability as inactive pharmaceutical constituents, particularly as disintegrants (inactive tablet ingredient whose function is to rapidly disrupt the tablet matrix on contact with gastric fluid). One of the more elegant approaches to improving palatability of ionizable drugs is the use of ion-exchange resins as taste-masking agents. The selection, optimization of drug:resin ratio and particle size, together with a review of scaleup of typical manufacturing processes for taste-masked products are provided. Ion-exchange resins have been extensively utilized in oral sustained-release products. The selection, optimization of drug:resin ratio and particle size, together with a summary of commonly occurring commercial sustained-release products are discussed. Ion-exchange resins have also been used in topical products for local application to the skin, including those where drug flux is controlled by a differential electrical current (ionotophoretic delivery). General applicability of ion-exchange resins, including ophthalmic delivery, nasal delivery, use as drugs in their own right (e.g., colestyramine, formerly referred to as cholestyramine), as well as measuring gastrointestinal transit times, are discussed. Finally, pharmaceutical monographs for ion-exchange resins are reviewed.

  3. Kinetic characteristics of the luminescence decay for industrial yttrium-gadolinium-aluminium garnet based phosphors

    NASA Astrophysics Data System (ADS)

    Lisitsyn, V. M.; Stepanov, S. A.; Valiev, D. T.; Vishnyakova, E. A.; Abdullin, H. A.; Marhabaeva, A. A.; Tulegenova, A. T.

    2016-02-01

    The spectral and decay kinetic characteristics of pulse cathodoluminescence and photoluminescence of phosphors based on yttrium-gadolinium-aluminum garnet were investigated using pulsed optical time resolved spectroscopy.

  4. Relined fiberglass post: an ex vivo study of the resin cement thickness and dentin-resin interface.

    PubMed

    Souza, Niélli Caetano de; Marcondes, Maurem Leitão; Breda, Ricardo Vaz; Weber, João Batista Blessmann; Mota, Eduardo Gonçalves; Spohr, Ana Maria

    2016-08-18

    The aim of this study was to evaluate the thickness of resin cements in the root thirds when using conventional fiberglass posts (CP) and relined fiberglass posts (RP) in weakened roots and to evaluate the morphological characteristics of the dentin-resin interface. Forty human maxillary anterior teeth had the crown sectioned below the cemento-enamel junction. The canals were endodontically treated and weakened with diamond burs. Teeth were divided into four groups (n = 10): Group 1 - CP + RelyX ARC; Group 2 - CP + RelyX U200; Group 3 - RP + RelyX ARC; and Group 4 - RP + RelyX U200. Prior to luting, 0.1% Fluorescein and 0.1% Rhodamine B dyes were added to an adhesive and resin cement, respectively. Slices were obtained from the apical, middle, and cervical thirds of the root. Confocal laser scanning microscopy images were recorded in four areas (buccal, lingual, mesial, distal) of each third. In each area, four equidistant measures of the resin cement were made and the mean value was calculated. The interface morphology was observed. The data were submitted to three-way ANOVA and Tukey's test (α = 0.05). The interaction between fiberglass posts, resin cement, and root thirds was significant (p < 0.0001). The resin cement thicknesses were significantly lower for RP in comparison with CP, except in the apical third. There was no significant difference between the resin cements for RP. There was formation of resin cement tags and adhesive tags along the root for RP. RP favored the formation of thin and uniform resin cement films and resin tags in weakened roots.

  5. Ponderosa pine resin defenses and growth: metrics matter.

    PubMed

    Hood, Sharon; Sala, Anna

    2015-11-01

    Bark beetles (Coleoptera: Curculionidae, Scolytinae) cause widespread tree mortality in coniferous forests worldwide. Constitutive and induced host defenses are important factors in an individual tree's ability to survive an attack and in bottom-up regulation of bark beetle population dynamics, yet quantifying defense levels is often difficult. For example, in Pinus spp., resin flow is important for resistance to bark beetles but is extremely variable among individuals and within a season. While resin is produced and stored in resin ducts, the specific resin duct metrics that best correlate with resin flow remain unclear. The ability and timing of some pine species to produce induced resin is also not well understood. We investigated (i) the relationships between ponderosa pine (Pinus ponderosa Lawson & C. Lawson) resin flow and axial resin duct characteristics, tree growth and physiological variables, and (ii) if mechanical wounding induces ponderosa pine resin flow and resin ducts in the absence of bark beetles. Resin flow increased later in the growing season under moderate water stress and was highest in faster growing trees. The best predictors of resin flow were nonstandardized measures of resin ducts, resin duct size and total resin duct area, both of which increased with tree growth. However, while faster growing trees tended to produce more resin, models of resin flow using only tree growth were not statistically significant. Further, the standardized measures of resin ducts, density and duct area relative to xylem area, decreased with tree growth rate, indicating that slower growing trees invested more in resin duct defenses per unit area of radial growth, despite a tendency to produce less resin overall. We also found that mechanical wounding induced ponderosa pine defenses, but this response was slow. Resin flow increased after 28 days, and resin duct production did not increase until the following year. These slow induced responses may allow

  6. Biphenyl liquid crystalline epoxy resin as a low-shrinkage resin-based dental restorative nanocomposite.

    PubMed

    Hsu, Sheng-Hao; Chen, Rung-Shu; Chang, Yuan-Ling; Chen, Min-Huey; Cheng, Kuo-Chung; Su, Wei-Fang

    2012-11-01

    Low-shrinkage resin-based photocurable liquid crystalline epoxy nanocomposite has been investigated with regard to its application as a dental restoration material. The nanocomposite consists of an organic matrix and an inorganic reinforcing filler. The organic matrix is made of liquid crystalline biphenyl epoxy resin (BP), an epoxy resin consisting of cyclohexylmethyl-3,4-epoxycyclohexanecarboxylate (ECH), the photoinitiator 4-octylphenyl phenyliodonium hexafluoroantimonate and the photosensitizer champhorquinone. The inorganic filler is silica nanoparticles (∼70-100 nm). The nanoparticles were modified by an epoxy silane of γ-glycidoxypropyltrimethoxysilane to be compatible with the organic matrix and to chemically bond with the organic matrix after photo curing. By incorporating the BP liquid crystalline (LC) epoxy resin into conventional ECH epoxy resin, the nanocomposite has improved hardness, flexural modulus, water absorption and coefficient of thermal expansion. Although the incorporation of silica filler may dilute the reinforcing effect of crystalline BP, a high silica filler content (∼42 vol.%) was found to increase the physical and chemical properties of the nanocomposite due to the formation of unique microstructures. The microstructure of nanoparticle embedded layers was observed in the nanocomposite using scanning and transmission electron microscopy. This unique microstructure indicates that the crystalline BP and nanoparticles support each other and result in outstanding mechanical properties. The crystalline BP in the LC epoxy resin-based nanocomposite was partially melted during exothermic photopolymerization, and the resin expanded via an order-to-disorder transition. Thus, the post-gelation shrinkage of the LC epoxy resin-based nanocomposite is greatly reduced, ∼50.6% less than in commercialized methacrylate resin-based composites. This LC epoxy nanocomposite demonstrates good physical and chemical properties and good biocompatibility

  7. 21 CFR 872.3140 - Resin applicator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3140 Resin applicator. (a) Identification. A resin applicator is a brushlike device intended for use in spreading dental resin on a tooth during application of...

  8. Photoaffinity labeling of the human erythrocyte glucose transporter with /sup 4/H-labelled forskolin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shanahan, M.F.; Edwards, B.M.; Morris, D.P.

    1986-05-01

    Forskolin, a potent activator of adenylate cyclase, is also known to inhibit glucose transport in a number of cells. The authors have investigated photoincorporation of (/sup 3/H)forskolin into erythrocyte membrane proteins using a technique they previously developed for photolabeling the erythrocyte glucose transporter with cytochalasin B (CB). A 30-40s irradiation of erythrocyte ghosts in the presence of (/sup 3/H)forskolin resulted in a concentration-dependent, covalent incorporation of radiolabel into all of the major membrane protein bands. However, most of the incorporation occurred in only three regions of the gel. Peak 1 was a sharp peak near the top of the gelmore » in the region corresponding to spectrin, peak 2 appeared to be associated with band 3 (approx. 90kDa), and the third region labeled was between 41-60 kDa which corresponds to the region of the glucose transporter. This region appeared to contain several overlapping peaks with the largest incorporation of label occurring around 45 kDa in the area of red cell actin. When photolabeling was performed in the presence of 400 ..mu..M cytochalasin B (8.0 ..mu..M forskolin) the labeling in the 41-60 kDa region was totally inhibited while labeling of the 90 kDa peak was partially blocked. CB had no effect on the photolabeling of peak 1 by forskolin.« less

  9. Light-attenuating effect of dentin on the polymerization of light-activated restorative resins.

    PubMed

    Arikawa, Hiroyuki; Kanie, Takahito; Fujii, Koichi; Ban, Seiji; Takahashi, Hideo

    2004-12-01

    The light-attenuating effect of dentin on the mechanical properties of light-activated composite resins was evaluated using a simple experimental filter. The filter was designed to simulate the light transmittance and light diffusion characteristics of 1.0-mm thick dentin. The depth of cure, surface hardness, and flexural strength for 13 shades of three light-activated restorative resins were examined. These resins were cured either using direct irradiation with a light source, or indirect irradiation through the filter. The attenuation of light intensity by 1.0-mm thick dentin reached 85-90% in the 400-550 nm wavelength region. For all materials, the values of depth of cure, surface hardness on the top and bottom surfaces, and flexural strength of specimens irradiated indirectly through the simulated 1.0-mm thick dentin filter decreased by 37-60%, 16-55%, 50-83%, and 44-82% in comparison with those by direct irradiation, respectively. Recovery from mechanical properties' reduction was achieved when materials were irradiated 1.5-4 times longer than the standard irradiation time.

  10. Cobalt and Yttrium Modified TiO2 Nanotubes Based Dye-Sensitized Solar Cells for Solar-Energy Conversion

    NASA Astrophysics Data System (ADS)

    Shabanov, N. S.; Isaev, A. B.; Orudzhev, F. F.; Murliev, E. K.

    2018-01-01

    The solar-energy conversion in eosin-sensitized solar cells based on cobalt and yttrium modified TiO2 nanotubes has been studied.It is established that the doping with metal ions shifts the absorption edge for Co and Y doped titanium dioxide samples to longer and shorter wavelengths, respectively. The efficiency of solar energy conversion depends on the wide bandgap of the semiconductor anode and reaches a maximum (4.4%) for yttrium-doped TiO2 in comparison to that (4.1%) for pure titanium dioxide.

  11. Shear Bond Strength between Fiber-Reinforced Composite and Veneering Resin Composites with Various Adhesive Resin Systems.

    PubMed

    AlJehani, Yousef A; Baskaradoss, Jagan K; Geevarghese, Amrita; AlShehry, Marey A; Vallittu, Pekka K

    2016-07-01

    The aim of this research was to evaluate the shear bond strength of different laboratory resin composites bonded to a fiber-reinforced composite substrate with some intermediate adhesive resins. Mounted test specimens of a bidirectional continuous fiber-reinforced substrate (StickNet) were randomly assigned to three equal groups. Three types of commercially available veneering resin composites - BelleGlass®, Sinfony®, and GC Gradia® were bonded to these specimens using four different adhesive resins. Half the specimens per group were stored for 24 hours; the remaining were stored for 30 days. There were 10 specimens in the test group (n). The shear bond strengths were calculated and expressed in MPa. Data were analyzed statistically, and variations in bond strength within each group were additionally evaluated by calculating the Weibull modulus. Shear bond values of those composites are influenced by the different bonding resins and different indirect composites. There was a significant difference in the shear bond strengths using different types of adhesive resins (p = 0.02) and using different veneering composites (p < 0.01). Belle-Glass® had the highest mean shear bond strength when bonded to StickNet substrate using both Prime & Bond NT and OptiBond Solo Plus. Sinfony® composite resin exhibited the lowest shear bond strength values when used with the same adhesive resins. The adhesive mode of failure was higher than cohesive with all laboratory composite resins bonded to the StickNet substructure at both storage times. Water storage had a tendency to lower the bond strengths of all laboratory composites, although the statistical differences were not significant. Within the limitations of this study, it was found that bonding of the veneering composite to bidirectional continuous fiber-reinforced substrate is influenced by the brand of the adhesive resin and veneering composite. © 2015 by the American College of Prosthodontists.

  12. Effects of erbium-and chromium-doped yttrium scandium gallium garnet and diode lasers on the surfaces of restorative dental materials: a scanning electron microscope study.

    PubMed

    Hatipoglu, M; Barutcigil, C

    2015-01-01

    The aim of this study is to evaluate the potential effects of laser irradiation, which is commonly performed in periodontal surgery, on the surfaces of restorative materials. Five different restorative dental materials were used in this study, as follows: (1) Resin composite, (2) poly acid-modified resin composite (compomer), (3) conventional glass ionomer cement (GIC), (4) resin-modified glass ionomer cement (RMGIC), and (5) amalgam. Four cylindrical samples (8 mm diameter, 2 mm height) were prepared for each restorative material. In addition, four freshly extracted, sound human incisors teeth were selected. Two different laser systems commonly used in periodontal surgery were examined in this study: A 810 nm diode laser at a setting of 1 W with continuous-phase laser irradiation for 10 s, and an erbium-and chromium-doped yttrium scandium gallium garnet (Er, Cr: YSGG) laser at settings of 2.5 W, 3.25 W, and 4 W with 25 Hz laser irradiation for 10 s. Scanning electron microscopy (SEM) analysis was performed to evaluate the morphology and surface deformation of the restorative materials and tooth surfaces. According to the SEM images, the Er, Cr: YSGG laser causes irradiation markings that appear as demineralized surfaces on tooth samples. The Er, Cr: YSGG laser also caused deep defects on composite, compomer, and RMGIC surfaces because of its high power, and the ablation was deeper for these samples. High-magnification SEM images of GIC samples showed the melting and combustion effects of the Er, Cr: YSGG laser, which increased as the laser power was increased. In amalgam samples, neither laser left significant harmful effects at the lowest power setting. The diode laser did cause irradiation markings, but they were insignificant compared with those left by the Er, Cr: YSGG laser on the surfaces of the different materials and teeth. Within the limitations of this study, it can be concluded that Er, Cr: YSGG laser irradiation could cause distortions of the surfaces

  13. Rheologic properties of flowable, conventional hybrid, and condensable composite resins.

    PubMed

    Lee, In-Bog; Son, Ho-Hyun; Um, Chung-Moon

    2003-06-01

    This research was undertaken to investigate the viscoelastic properties related to handling characteristics of five commercial flowable, two conventional hybrid and two condensable composite resins and to investigate the effect on the viscosity of filler volume fraction of composites. A dynamic oscillatory shear test was used to evaluate the storage shear modulus (G'), loss shear modulus (G"), loss tangent (tan delta) and complex viscosity (eta(*)) of the composite resins as a function of frequency (omega)-dynamic frequency sweep test from 0.01 to 100 rad/s at 25 degrees C-using an Advanced Rheometric Expansion System. To investigate the effect on the viscosity of the composites of the filler volume fraction, the filler weight% and filler volume% were measured by the Archimedes' principle using a pyknometer. The complex viscosity eta(*) of flowable composites was lower than that of the hybrid composites and significant differences were observed between brands. The complex viscosity eta(*) of condensable composites was higher than that of hybrid composites. The order of complex viscosity eta(*) at omega=10 rad/s in order of decreasing viscosity was as follows, Synergy compact, P-60, Z-250, Z-100, Aeliteflo, Tetric flow, Compoglass flow, Flow it and Revolution. The complex viscosity of flowable composites, normalized with respect to Z-100, was 0.04-0.56 but Synergy compact was 2.158 times higher than that of Z-100. The patterns of the change of loss tangent (tan delta) of the composite resins with increasing frequency were significantly different between brands. Phase angles delta ranged from 30.9 to 78.1 degrees at omega=10 rad/s. All composite resins exhibit pseudoplastic behavior with increasing shear rate. The relationships between the complex shear modulus G(*), the phase angle delta, and the shear rate omega were represented by the frequency domain phasor form, G(*)(omega)=G(*)e(i delta)=G(*) 90 degree angle delta. Only a weak relationship was found between

  14. Quality control assurance of strontium-90 in foodstuffs by LSC.

    PubMed

    Lopes, I; Mourato, A; Abrantes, J; Carvalhal, G; Madruga, M J; Reis, M

    2014-11-01

    A method based on the separation of Sr-90 by extraction chromatography and beta determination by Liquid Scintillation Counting (LSC) technique was used for strontium analysis in food samples. The methodology consisted in prior sample treatment (drying and incineration) followed by radiochemical separation of Sr-90 by extraction chromatography, using the Sr-resin. The chemical yield was determined by gravimetric method, adding stable strontium to the matrix. Beta activity (Sr-90/Y-90) was determined using a low background liquid scintillation spectrometer (Tri-Carb 3170 TR/SL, Packard). The accuracy and the precision of the method, was performed previously through recovery trials with Sr-90 spiked samples, using the same type of matrices (milk, complete meals, meat and vegetables). A reference material (IAEA_321) was now used to measure the accuracy of the procedure. Participation in interlaboratory comparison exercises was also performed in order to establish an external control on the measurements and to ensure the adequacy of the method. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Polythermal investigation of viscosity of solution of metal carboxylates in VIK-grade mixed carboxylic acids: Yttrium and gadolinium carboxylates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mezhov, E.A.; Samatov, A.V.; Troyanovskii, L.V.

    Kinematic viscosities have been measured for solutions of yttrium and gadolinium carboxylates in grade VIK mixed carboxylic acids (MCA). It has been established that the optimal fluidity of these metal carboxylate solutions for application to articles is reached at 333 K. A regression model has been developed to describe the concentration and temperature dependences of the viscosity of yttrium- and gadolinium-containing MCA solutions. 2 refs., 3 tabs.

  16. [Physical properties of resins for veneer crown. (Part 1) Bending strength of thermosetting methacrylic resins (author's transl)].

    PubMed

    Kashiwada, T

    1979-01-01

    The physical properties of thermosetting methacrylic resins contain a kind or more than two kinds of cross linking agents were investigated. Knoop hardness and bending strength after drying, water sorption and thermal cycling were listed in table 4 and 5. Hydrophilic resins absorbed water about 3 times as much as hydrophobic resins. The materials contain a small amount of hydrophobic cross linking agents in MMA indicate comparatively excellent properties after drying, water sorption and thermal cycling. Knoop hardness of resins generally reduced by water sorption, especially in the case of the resin contains a large amount of triethylene glycol dimethacrylate.

  17. Biocompatibility of composite resins

    PubMed Central

    Mousavinasab, Sayed Mostafa

    2011-01-01

    Dental materials that are used in dentistry should be harmless to oral tissues, so they should not contain any leachable toxic and diffusible substances that can cause some side effects. Reports about probable biologic hazards, in relation to dental resins, have increased interest to this topic in dentists. The present paper reviews the articles published about biocompatibility of resin-restorative materials specially resin composites and monomers which are mainly based on Bis-GMA and concerns about their degradation and substances which may be segregated into oral cavity. PMID:23372592

  18. [Investigation on the process of sapindus saponin purified with macroporous adsorption resin and screening of its bacteriostasis].

    PubMed

    Fu, Yong; Lei, Peng; Han, Yu-mei; Yan, Dan

    2010-02-01

    To study the technological parameters of the purification process of saponins with macroporous adsorption resin. The adsorptive characteristics and elutive parameters of the process were studied by taking the elutive and purified ratio of saponins as markers. Bacteriostasis activity of each parts eluted was evaluated by the mean of cup-plate method. 13.6 mL of the extraction of sapindus saponin (crude drugs 0.01 g/mL) was purified with a column of macroporous adsorption resin (phi15 mm x H90 mm, dry weight 2.5 g) and washed with 3BV of distilled water, then eluted with 3BV of 30% ethanol and 3BV of 70% ethanol, most of saponins were collected in the 70% ethanol. With macroporous adsorption resin adsorbing and purifying, the elutive ratio of saponins was 93.8% and the purity reached 250.1%. So this process of applying macroporous adsorption resin to adsorb and purify saponins is feasible, and supplies reference to the purification of other types of saponin.

  19. Separation and purification of both tea seed polysaccharide and saponin from camellia cake extract using macroporous resin.

    PubMed

    Yang, Pengjie; Zhou, Mingda; Zhou, Chengyun; Wang, Qian; Zhang, Fangfang; Chen, Jian

    2015-02-01

    A novel method to separate and purify tea seed polysaccharide and tea seed saponin from camellia cake extract by macroporous resin was developed. Among four kinds of resins (AB-8, NKA-9, XDA-6, and D4020) tested, AB-8 macroporous resin possessed optimal separating capacity for the two substances and thus was selected for the separation, in which deionized water was used to elute tea seed polysaccharide, 0.25% NaOH solution to remove the undesired pigments, and 90% ethanol to elute tea seed saponin. Further dynamic adsorption/desorption experiments on AB-8 resin-based column chromatography were conducted to obtain the optimal parameters. Under optimal dynamic adsorption and desorption conditions, 18.7 and 11.8% yield of tea seed polysaccharide and tea seed saponin were obtained with purities of 89.2 and 96.0%, respectively. The developed method provides a potential approach for the large-scale production of tea seed polysaccharide and tea seed saponin from camellia cake. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Early hardness of self-adhesive resin cements cured under indirect resin composite restorations.

    PubMed

    Giráldez, Isabel; Ceballos, Laura; Garrido, Miguel A; Rodríguez, Jesús

    2011-04-01

    To determine the influence of curing mode on the surface hardness of seven resin cements used to lute indirect composite restorations. Seven commercial dual-curing resin cements were tested: two were total-etch (RelyX ARC [3M ESPE, St. Paul, MN, USA] and Variolink II [Ivoclar Vivadent, Schaan, Liechtenstein]); one was self-etch (Multilink Automix [Ivoclar Vivadent]), and four were self-adhesive (RelyX Unicem [3M ESPE], Maxcem Elite [Kerr Corp., Orange, CA, USA], SmartCem2 [Dentsply, Detrey, GmbH, Konstanz, Germany], and G-Cem [GC CORPORATION, Itabashi-Ku, Tokyo, Japan]). Three specimens (0.5 × 6.5mm) of each material were prepared for each of three experimental groups: Group 1 (cements allowed to self cure); Group 2 (cements light-cured for 40 seconds); and Group 3 (cements light-cured for 80 seconds). All specimens were cured through a 4-mm-thick composite cylinder (Filtek Z250-A3). Surface microhardness numbers were determined at 20 min after preparation. Results were analyzed by two-way analysis of variance and Student-Newman-Keuls tests (p<0.05). Superficial hardness was significantly influenced by the resin cement tested (p<0.0001), the curing mode (p<0.0001), and their interaction (p<0.0001). RelyX ARC exhibited the highest mean microhardness values regardless of the curing mode. Light-curing significantly increased the microhardness of all resin cements studied, and these values increased even further with a doubling of irradiation time. Self-adhesive cements exhibited different behavior according to the curing mode. RelyX Unicem was highly sensitive to light irradiation, showing the lowest mean values in the self-curing mode. After light irradiation for 40 or 80 seconds, Maxcem Elite exhibited the lowest mean hardness values of all the resin cements tested. The microhardness of resin cements is highly dependent on the brand. Dual-curing resin cements should always be light irradiated for longer periods than that recommended by manufacturers. Dual

  1. Demonstration of New, Highly Perchlorate-Selective Ion Exchange Resin Coupled with Resin-Optimized, Single-Vessel Engineering Design

    DTIC Science & Technology

    2013-03-01

    effluent by ion chromatography (method described in Appendix A) Resin Separation Will remove >95% of fully exhausted resin (below mid-lateral...and retain >95% of the unexhausted resin (above the mid-lateral). 1) Mass balance on ClO4- during each cycle using ion chromatography and resin...Application Note 134, “Determination of Low Concentrations of Perchlorate in Drinking and Ground Waters Using Ion Chromatography ” and Product Note

  2. Synthesis and characterizations of melamine-based epoxy resins.

    PubMed

    Ricciotti, Laura; Roviello, Giuseppina; Tarallo, Oreste; Borbone, Fabio; Ferone, Claudio; Colangelo, Francesco; Catauro, Michelina; Cioffi, Raffaele

    2013-09-05

    A new, easy and cost-effective synthetic procedure for the preparation of thermosetting melamine-based epoxy resins is reported. By this innovative synthetic method, different kinds of resins can be obtained just by mixing the reagents in the presence of a catalyst without solvent and with mild curing conditions. Two types of resins were synthesized using melamine and a glycidyl derivative (resins I) or by adding a silane derivative (resin II). The resins were characterized by means of chemical-physical and thermal techniques. Experimental results show that all the prepared resins have a good thermal stability, but differ for their mechanical properties: resin I exhibits remarkable stiffness with a storage modulus value up to 830 MPa at room temperature, while lower storage moduli were found for resin II, indicating that the presence of silane groups could enhance the flexibility of these materials. The resins show a pot life higher than 30 min, which makes these resins good candidates for practical applications. The functionalization with silane terminations can be exploited in the formulation of hybrid organic-inorganic composite materials.

  3. Synthesis and Characterizations of Melamine-Based Epoxy Resins

    PubMed Central

    Ricciotti, Laura; Roviello, Giuseppina; Tarallo, Oreste; Borbone, Fabio; Ferone, Claudio; Colangelo, Francesco; Catauro, Michelina; Cioffi, Raffaele

    2013-01-01

    A new, easy and cost-effective synthetic procedure for the preparation of thermosetting melamine-based epoxy resins is reported. By this innovative synthetic method, different kinds of resins can be obtained just by mixing the reagents in the presence of a catalyst without solvent and with mild curing conditions. Two types of resins were synthesized using melamine and a glycidyl derivative (resins I) or by adding a silane derivative (resin II). The resins were characterized by means of chemical-physical and thermal techniques. Experimental results show that all the prepared resins have a good thermal stability, but differ for their mechanical properties: resin I exhibits remarkable stiffness with a storage modulus value up to 830 MPa at room temperature, while lower storage moduli were found for resin II, indicating that the presence of silane groups could enhance the flexibility of these materials. The resins show a pot life higher than 30 min, which makes these resins good candidates for practical applications. The functionalization with silane terminations can be exploited in the formulation of hybrid organic-inorganic composite materials. PMID:24013372

  4. Thermoelectric properties of the yttrium-doped ceramic oxide SrTiO3

    NASA Astrophysics Data System (ADS)

    Khan, Tamal Tahsin; Ur, Soon-Chul

    2017-01-01

    The doping dependence of the thermoelectric figure of merit, ZT, of the ceramic oxide SrTiO3 at high temperature has been studied. In this study, yttrium was used as the doping element. A conventional solid-state reaction method was used for the preparation of Y-doped SrTiO3. The doping level in SrTiO3 was controlled to be in the doping range of 2 - 10 mole%. Almost all the yttrium atoms incorporated into the SrTiO3 provided charge carriers, as was observed by using X-ray diffraction pattern. The relative densities of all the samples varied from 98.53% to 99.45%. The thermoelectric properties, including the electrical conductivity σ, Seebeck coefficient S, thermal conductivity k, and the figure of merit, ZT, were investigated at medium temperatures. The ZT value showed an obvious doping level dependence, in which a value as high as 0.18 is realized at 773 K for a doping of 8 mole%.

  5. Fiberboard bending properties as a function of density, thickness, resin, and moisture content

    Treesearch

    John F. Hunt; Jane O' Dell; Chris Turk

    2008-01-01

    Fibers from treetop residues of lodgepole pine (Pinus contorta) and recycled old corrugated containers were used to fabricate wet-formed fiberboard panels over a range of densities from 300 to 1100 kg m-3, a thickness range from 1.3 to 4.8 mm, and phenolic resin contents from 0% to 4.5%. The panels were then tested after conditioning in 50% and 90% relative humidity (...

  6. Ion beam irradiation of lanthanum and thorium-doped yttrium titanates

    NASA Astrophysics Data System (ADS)

    Lian, J.; Zhang, F. X.; Peters, M. T.; Wang, L. M.; Ewing, R. C.

    2007-05-01

    Y2Ti2O7 pyrochlores doped with La have been sintered at 1373 K for 12 h with the designed compositions of the (LaxY1-x)2Ti2O7 system (x = 0, 0.08, 0.5, and 1), and the phase compositions were analyzed by X-ray diffraction. Limited amounts of La were incorporated into yttrium titanate pyrochlore structure for La-doped samples; while, the end member composition of La2Ti2O7 formed a layered perovskite structure. Ion beam-induced amorphization occurred for all compositions in the (LaxY1-x)2Ti2O7 binary under 1 MeV Kr2+ irradiation at room temperature, and the critical amorphization dose decreased with increasing amounts of La3+. The critical amorphization temperatures for Y2Ti2O7, (La0.162Y0.838)2Ti2O7 and La2Ti2O7 were determined to be ∼780, 890 and 920 K, respectively. Th4+ and Fe3+-doped yttrium titanate pyrochlores were synthesized at 1373 K by sintering Y2Ti2O7 with (ThO2 + Fe2O3). Pyrochlore structures and the chemical compositions were primarily identified by the X-ray diffraction and energy dispersive X-ray (EDX) measurements. The lattice parameter and the critical amorphization dose (1 MeV Kr2+ at room temperature) increase for yttrium titanate pyrochlores with the addition of Th. The increasing 'resistance' to amorphization with less La and greater Th and Fe contents for (Y1-xLax)2Ti2O7 and Y2Ti2O7-Fe2O3-ThO2 systems, respectively, are consistent with the changes in the average ionic radius ratio at the A-sites and B-sites. These results suggest that the addition of lanthanides and actinides (e.g., Th, U, or Pu) will affect the structural stability, as well as the radiation response behavior of the pyrochlore structure-type.

  7. The Effect of Titanium Tetrafluoride and Sodium Hypochlorite on the Shear Bond Strength of Methacrylate and Silorane Based Composite Resins: an In-Vitro Study.

    PubMed

    Sharafeddin, Farahnaz; Koohpeima, Fatemeh; Razazan, Nader

    2017-06-01

    The bond strength of composites with different adhesive systems with dentin is an important factor in long term durability of composite restorations. The effect of titanium tetrafluoride (TiF 4 ) as anti caries agent and sodium hypochlorite (NaOCl) as disinfectant on the shear bond of nanofilled and silorane based composite resins have not been investigated in previous studies. This study was conducted to determine bond strength between dentin and two composite systems, by means of shear bond test using TiF 4 and NaOCl. Middle dentin of 60 intact extracted maxillary premolar teeth were exposed by sectioning the crowns at a depth of 2mm from central groove and parallel to the occlusal surface. Standardized smear layer was created using a 600-grit silicon carbide paper and then samples were embedded in acrylic resin blocks. Then the samples were randomly divided into 6 \\groups summarized as Group I: Z350, Group II: Z350+ NaOCl, Group III: Z350+ TiF 4 , Group IV: P90, Group V: P90+ NaOCl, Group VI: P90+ TiF 4 according to manufacturer's instruction. Then samples were subjected to shear bond strength (SBS) test using universal testing machine and data were analyzed using ANOVA and Tukey tests ( p < 0.05). Application of 5% NaOCl caused a significant decrease in SBS of nanofilled composite resin ( p = 0.004), and also silorane based composite resin ( p = 0.006). Application of 4% TiF 4 caused a significant increase in SBS of silorane based composite resin ( p = 0.001). The effect of TiF 4 on nanofilled composite was not statistically significant. Using TiF 4 has a positive effect on increasing the shear bond while NaOCl has negative effect on bond strength.

  8. Method for regenerating magnetic polyamine-epichlorohydrin resin

    DOEpatents

    Kochen, Robert L.; Navratil, James D.

    1997-07-29

    Magnetic polymer resins capable of efficient removal of actinides and heavy metals from contaminated water are disclosed together with methods for making, using, and regenerating them. The resins comprise polyamine-epichlorohydrin resin beads with ferrites attached to the surfaces of the beads. Markedly improved water decontamination is demonstrated using these magnetic polymer resins of the invention in the presence of a magnetic field, as compared with water decontamination methods employing ordinary ion exchange resins or ferrites taken separately.

  9. Effect of Resin Infiltration on Artificial Caries: An in vitro Evaluation of Resin Penetration and Microhardness.

    PubMed

    Prajapati, Deepesh; Nayak, Rashmi; Pai, Deepika; Upadhya, Nagraj; K Bhaskar, Vipin; Kamath, Pujan

    2017-01-01

    To evaluate the effectiveness of resin infiltration on artificial caries lesion by assessing the depth of resin penetration and the change in microhardness of lesion postinfiltration. Totally 45 human extracted premolars were used to create an artificial demineralized lesion in enamel using demineralizing solution. A total of 15 samples (group I) were infiltrated with resin. The depth of resin penetration was studied using scanning electron microscope (SEM). Other half (n = 30) of samples was equally divided into three subgroups and Vickers hardness number (VHN) values were obtained to measure the surface microhardness as group 11 a-before demineralization, 11 b-after demineralization, IIc-postresin infiltration. Mean depth of penetration in group I was 516.8 urn. There was statistically significant increase in VHN values of demineralized lesion postresin infiltration (independent Student's t-test, p < 0.001). Penetration depth of the resin infiltrant was deep enough to render beneficial effects, while significant increase in microhardness was observed postresin infiltration. Infiltrant used can be considered as a valid treatment option for noncavitated lesions. Prajapati D, Nayak R, Pai D, Upadhya N, Bhaskar VK, Kamath P. Effect of Resin Infiltration on Artificial Caries: An in vitro Evaluation of Resin Penetration and Microhardness. Int J Clin Pediatr Dent 2017;10(3):250-256.

  10. Rapid embedding methods into epoxy and LR White resins for morphological and immunological analysis of cryofixed biological specimens.

    PubMed

    McDonald, Kent L

    2014-02-01

    A variety of specimens including bacteria, ciliates, choanoflagellates (Salpingoeca rosetta), zebrafish (Danio rerio) embryos, nematode worms (Caenorhabditis elegans), and leaves of white clover (Trifolium repens) plants were high pressure frozen, freeze-substituted, infiltrated with either Epon, Epon-Araldite, or LR White resins, and polymerized. Total processing time from freezing to blocks ready to section was about 6 h. For epoxy embedding the specimens were freeze-substituted in 1% osmium tetroxide plus 0.1% uranyl acetate in acetone. For embedding in LR White the freeze-substitution medium was 0.2% uranyl acetate in acetone. Rapid infiltration was achieved by centrifugation through increasing concentrations of resin followed by polymerization at 100°C for 1.5-2 h. The preservation of ultrastructure was comparable to standard freeze substitution and resin embedding methods that take days to complete. On-section immunolabeling results for actin and tubulin molecules were positive with very low background labeling. The LR White methods offer a safer, quicker, and less-expensive alternative to Lowicryl embedding of specimens processed for on-section immunolabeling without traditional aldehyde fixatives.

  11. High throughput determination of cleaning solutions to prevent the fouling of an anion exchange resin.

    PubMed

    Elich, Thomas; Iskra, Timothy; Daniels, William; Morrison, Christopher J

    2016-06-01

    Effective cleaning of chromatography resin is required to prevent fouling and maximize the number of processing cycles which can be achieved. Optimization of resin cleaning procedures, however, can lead to prohibitive material, labor, and time requirements, even when using milliliter scale chromatography columns. In this work, high throughput (HT) techniques were used to evaluate cleaning agents for a monoclonal antibody (mAb) polishing step utilizing Fractogel(®) EMD TMAE HiCap (M) anion exchange (AEX) resin. For this particular mAb feed stream, the AEX resin could not be fully restored with traditional NaCl and NaOH cleaning solutions, resulting in a loss of impurity capacity with resin cycling. Miniaturized microliter scale chromatography columns and an automated liquid handling system (LHS) were employed to evaluate various experimental cleaning conditions. Cleaning agents were monitored for their ability to maintain resin impurity capacity over multiple processing cycles by analyzing the flowthrough material for turbidity and high molecular weight (HMW) content. HT experiments indicated that a 167 mM acetic acid strip solution followed by a 0.5 M NaOH, 2 M NaCl sanitization provided approximately 90% cleaning improvement over solutions containing solely NaCl and/or NaOH. Results from the microliter scale HT experiments were confirmed in subsequent evaluations at the milliliter scale. These results identify cleaning agents which may restore resin performance for applications involving fouling species in ion exchange systems. In addition, this work demonstrates the use of miniaturized columns operated with an automated LHS for HT evaluation of chromatographic cleaning procedures, effectively decreasing material requirements while simultaneously increasing throughput. Biotechnol. Bioeng. 2016;113: 1251-1259. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. Vitrification of ion exchange resins

    DOEpatents

    Cicero-Herman, Connie A.; Workman, Rhonda Jackson

    2001-01-01

    The present invention relates to vitrification of ion exchange resins that have become loaded with hazardous or radioactive wastes, in a way that produces a homogenous and durable waste form and reduces the disposal volume of the resin. The methods of the present invention involve directly adding borosilicate glass formers and an oxidizer to the ion exchange resin and heating the mixture at sufficient temperature to produce homogeneous glass.

  13. Biocidal quaternary ammonium resin

    NASA Technical Reports Server (NTRS)

    Janauer, G. E.

    1983-01-01

    Activated carbon (charcoal) and polymeric resin sorbents are widely used in the filtration and treatment of drinking water, mainly to remove dissolved organic and inorganic impurities and to improve the taste. Earlier hopes that activated carbon might "disinfect' water proved to be unfounded. The feasibility of protecting against microbial infestation in charcoal and resin beds such as those to be incorporated into total water reuse systems in spacecraft was investigated. The biocidal effect of IPCD (insoluable polymeric contact disinfectants) in combination with a representative charcoal was assessed. The ion exchange resins (IPCD) were shown to adequately protect charcoal and ion exchange beds.

  14. Resin/graphite fiber composites

    NASA Technical Reports Server (NTRS)

    Cavano, P. J.; Jones, R. J.; Vaughan, R. W.

    1972-01-01

    High temperature resin matrices suitable for use in advanced graphite fiber composites for jet engine applications were evaluated. A series of planned, sequential screening experiments with resin systems in composite form were performed to reduce the number of candidates to a single A-type polyimide resin that repetitively produced void-free, high strength and modulus composites acceptable for use in the 550 F range for 1000 hours. An optimized processing procedure was established for this system. Extensive mechanical property studies characterized this single system, at room temperature, 500 F, 550 F and 600 F, for various exposure times.

  15. Composites with improved fiber-resin interfacial adhesion

    NASA Technical Reports Server (NTRS)

    Cizmecioglu, Muzaffer (Inventor)

    1989-01-01

    The adhesion of fiber reinforcement such as high modulus graphite to a matrix resin such as polycarbonate is greatly enhanced by applying a very thin layer, suitably from 50 Angstroms to below 1000 Angstroms, to the surface of the fiber such as by immersing the fiber in a dilute solution of the matrix resin in a volatile solvent followed by draining to remove excess solution and air drying to remove the solvent. The thin layer wets the fiber surface. The very dilute solution of matrix resin is able to impregnate multifilament fibers and the solution evenly flows onto the surface of the fibers. A thin uniform layer is formed on the surface of the fiber after removal of the solvent. The matrix resin coated fiber is completely wetted by the matrix resin during formation of the composite. Increased adhesion of the resin to the fibers is observed at fracture. At least 65 percent of the surface of the graphite fiber is covered with polycarbonate resin at fracture whereas uncoated fibers have very little matrix resin adhering to their surfaces at fracture and epoxy sized graphite fibers exhibit only slightly higher coverage with matrix resin at fracture. Flexural modulus of the composite containing matrix resin coated fibers is increased by 50 percent and flexural strength by 37 percent as compared to composites made with unsized fibers.

  16. 49 CFR 173.165 - Polyester resin kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Polyester resin kits. 173.165 Section 173.165... Polyester resin kits. (a) Except for transportation by aircraft, polyester resin kits consisting of a base... resin kits consisting of a base material component (Class 3, Packing Group II or III) and an activator...

  17. Magnetocrystalline anisotropy of Fe2 + ion in silicon- or germanium-substituted yttrium iron garnet at zero temperature

    NASA Astrophysics Data System (ADS)

    Rudowicz, Czeslaw

    1982-01-01

    The present work reports the theoretical considerations of the magnetocrystalline anisotropy of ferrous ions induced by tetravalent dopants in yttrium iron garnet. Using the spin Hamiltonian developed earlier by us and the molecular field (h) approximation we derive the cubic anisotropy constants K1 and K2 at zero temperature. We adopt the Alben's et al. model of twelve inequivalent Fe2+ sites in silicon-substituted yttrium iron garnet. Results are given for h = 400, 300, 200 and the spin Hamiltonian parameters with the trigonal Δ = 300, 400, 500, 600, 700 and the nontrigonal crystal field parameter Γ = 200, 300 cm-1. The agreement with the experimental K1 and K2 is quite good. The discussion reveals that the properties of the far and near sites in the two-center model can now be theoretically explained. The theoretical ratios of K1(far) to K1(near) agree well with experiment. Thus our results speak in favor of the orbital singlet rather than the doublet model assumed previously for Fe2+ in silicon- or germanium-substituted yttrium iron garnets.

  18. Influence of Yttrium Ion-Implantation on the Growth Kinetics and Micro-Structure of NiO Oxide Film

    NASA Astrophysics Data System (ADS)

    Jin, Huiming; Adriana, Felix; Majorri, Aroyave

    2008-02-01

    Isothermal and cyclic oxidation behaviours of pure and yttrium-implanted nickel were studied at 1000°C in air. Scanning electronic microscopy (SEM) and transmission electronic microscopy (TEM) were used to examine the micro-morphology and structure of oxide scales formed on the nickel substrate. It was found that Y-implantation significantly improved the anti-oxidation ability of nickel in both isothermal and cyclic oxidizing experiments. Laser Raman microscopy was also used to study the stress status of oxide scales formed on nickel with and without yttrium. The main reason for the improvement in anti-oxidation of nickel was that Y-implantation greatly reduced the growing speed and grain size of NiO. This fine-grained NiO oxide film might have better high temperature plasticity and could relieve parts of compressive stress by means of creeping, and maintained a ridge character and a relatively low internal stress level. Hence yttrium ion-implantation remarkably enhanced the adhesion of protective NiO oxide scale formed on the nickel substrate.

  19. Method for regenerating magnetic polyamine-epichlorohydrin resin

    DOEpatents

    Kochen, R.L.; Navratil, J.D.

    1997-07-29

    Magnetic polymer resins capable of efficient removal of actinides and heavy metals from contaminated water are disclosed together with methods for making, using, and regenerating them. The resins comprise polyamine-epichlorohydrin resin beads with ferrites attached to the surfaces of the beads. Markedly improved water decontamination is demonstrated using these magnetic polymer resins of the invention in the presence of a magnetic field, as compared with water decontamination methods employing ordinary ion exchange resins or ferrites taken separately. 9 figs.

  20. Partition Model-Based 99mTc-MAA SPECT/CT Predictive Dosimetry Compared with 90Y TOF PET/CT Posttreatment Dosimetry in Radioembolization of Hepatocellular Carcinoma: A Quantitative Agreement Comparison.

    PubMed

    Gnesin, Silvano; Canetti, Laurent; Adib, Salim; Cherbuin, Nicolas; Silva Monteiro, Marina; Bize, Pierre; Denys, Alban; Prior, John O; Baechler, Sebastien; Boubaker, Ariane

    2016-11-01

    90 Y-microsphere selective internal radiation therapy (SIRT) is a valuable treatment in unresectable hepatocellular carcinoma (HCC). Partition-model predictive dosimetry relies on differential tumor-to-nontumor perfusion evaluated on pretreatment 99m Tc-macroaggregated albumin (MAA) SPECT/CT. The aim of this study was to evaluate agreement between the predictive dosimetry of 99m Tc-MAA SPECT/CT and posttreatment dosimetry based on 90 Y time-of-flight (TOF) PET/CT. We compared the 99m Tc-MAA SPECT/CT results for 27 treatment sessions (25 HCC patients, 41 tumors) with 90 Y SIRT (7 glass spheres, 20 resin spheres) and the posttreatment 90 Y TOF PET/CT results. Three-dimensional voxelized dose maps were computed from the 99m Tc-MAA SPECT/CT and 90 Y TOF PET/CT data. Mean absorbed dose ([Formula: see text]) was evaluated to compute the predicted-to-actual dose ratio ([Formula: see text]) in tumor volumes (TVs) and nontumor volumes (NTVs) for glass and resin spheres. The Lin concordance ([Formula: see text]) was used to measure accuracy ([Formula: see text]) and precision (ρ). Administered activity ranged from 0.8 to 1.9 GBq for glass spheres and from 0.6 to 3.4 GBq for resin spheres, and the respective TVs ranged from 2 to 125 mL and from 6 to 1,828 mL. The mean dose [Formula: see text] was 240 Gy for glass and 122 Gy for resin in TVs and 72 Gy for glass and 47 Gy for resin in NTVs. [Formula: see text] was 1.46 ± 0.58 (0.65-2.53) for glass and 1.16 ± 0.41 (0.54-2.54) for resin, and the respective values for [Formula: see text] were 0.88 ± 0.15 (0.56-1.00) and 0.86 ± 0.2 (0.58-1.35). DR variability was substantially lower in NTVs than in TVs. The Lin concordance between [Formula: see text] and [Formula: see text] (resin) was significantly better for tumors larger than 150 mL than for tumors 150 mL or smaller ([Formula: see text] = 0.93 and [Formula: see text] = 0.95 vs. [Formula: see text] = 0.57 and [Formula: see text] = 0.93; P < 0.05). In 90 Y radioembolization

  1. Tritium labeling of antisense oligonucleotides by exchange with tritiated water.

    PubMed Central

    Graham, M J; Freier, S M; Crooke, R M; Ecker, D J; Maslova, R N; Lesnik, E A

    1993-01-01

    We describe a simple, efficient, procedure for labeling oligonucleotides to high specific activity (< 1 x 10(8) cpm/mumol) by hydrogen exchange with tritiated water at the C8 positions of purines in the presence of beta-mercaptoethanol, an effective radical scavenger. Approximately 90% of the starting material is recovered as intact, labeled oligonucleotide. The radiolabeled compounds are stable in biological systems; greater than 90% of the specific activity is retained after 72 hr incubation at 37 degrees C in serum-containing media. Data obtained from in vitro cellular uptake experiments using oligonucleotides labeled by this method are similar to those obtained using 35S or 14C-labeled compounds. Because this protocol is solely dependent upon the existence of purine residues, it should be useful for radiolabeling modified as well as unmodified phosphodiester oligonucleotides. Images PMID:8367289

  2. Study of plasma off-gas treatment from spent ion exchange resin pyrolysis.

    PubMed

    Castro, Hernán Ariel; Luca, Vittorio; Bianchi, Hugo Luis

    2017-03-23

    Polystyrene divinylbenzene-based ion exchange resins are employed extensively within nuclear power plants (NPPs) and research reactors for purification and chemical control of the cooling water system. To maintain the highest possible water quality, the resins are regularly replaced as they become contaminated with a range of isotopes derived from compromised fuel elements as well as corrosion and activation products including 14 C, 60 Co, 90 Sr, 129 I, and 137 Cs. Such spent resins constitute a major proportion (in volume terms) of the solid radioactive waste generated by the nuclear industry. Several treatment and conditioning techniques have been developed with a view toward reducing the spent resin volume and generating a stable waste product suitable for long-term storage and disposal. Between them, pyrolysis emerges as an attractive option. Previous work of our group suggests that the pyrolysis treatment of the resins at low temperatures between 300 and 350 °C resulted in a stable waste product with a significant volume reduction (>50%) and characteristics suitable for long-term storage and/or disposal. However, another important issue to take into account is the complexity of the off-gas generated during the process and the different technical alternatives for its conditioning. Ongoing work addresses the characterization of the ion exchange resin treatment's off-gas. Additionally, the application of plasma technology for the treatment of the off-gas current was studied as an alternative to more conventional processes utilizing oil- or gas-fired post-combustion chambers operating at temperatures in excess of 1000 °C. A laboratory-scale flow reactor, using inductively coupled plasma, operating under sub-atmospheric conditions was developed. Fundamental experiments using model compounds have been performed, demonstrating a high destruction and removal ratio (>99.99%) for different reaction media, at low reactor temperatures and moderate power consumption

  3. 21 CFR 177.2260 - Filters, resin-bonded.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Filters, resin-bonded. 177.2260 Section 177.2260... Components of Articles Intended for Repeated Use § 177.2260 Filters, resin-bonded. Resin-bonded filters may... of this section. (a) Resin-bonded filters are prepared from natural or synthetic fibers to which have...

  4. 21 CFR 177.2260 - Filters, resin-bonded.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Filters, resin-bonded. 177.2260 Section 177.2260... Components of Articles Intended for Repeated Use § 177.2260 Filters, resin-bonded. Resin-bonded filters may... of this section. (a) Resin-bonded filters are prepared from natural or synthetic fibers to which have...

  5. 21 CFR 177.2260 - Filters, resin-bonded.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Filters, resin-bonded. 177.2260 Section 177.2260... Components of Articles Intended for Repeated Use § 177.2260 Filters, resin-bonded. Resin-bonded filters may... of this section. (a) Resin-bonded filters are prepared from natural or synthetic fibers to which have...

  6. 21 CFR 177.2260 - Filters, resin-bonded.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Filters, resin-bonded. 177.2260 Section 177.2260... Components of Articles Intended for Repeated Use § 177.2260 Filters, resin-bonded. Resin-bonded filters may... of this section. (a) Resin-bonded filters are prepared from natural or synthetic fibers to which have...

  7. Organic geochemistry of resins from modern Agathis australis and Eocene resins from New Zealand: Diagenetic and taxonomic implications

    USGS Publications Warehouse

    Lyons, P.C.; Mastalerz, Maria; Orem, W.H.

    2009-01-01

    A maturation series of resins and fossil resins from New Zealand, ranging in age from Modern to Eocene and ranging from uncoalified to high volatile C bituminous coal, were analyzed by elemental, pyrolysis-gas chromatography (Py-GC), Fourier Transform infrared (FTir), and solid-state 13C nuclear magnetic resonance (13C NMR) techniques. For comparison, four resin samples from the Latrobe Valley, Australia, were analyzed. All of the resins and fossil resins of this study show very high H/C atomic ratios, and are characterized by dominant peaks in the 10-60??ppm range of solid-state 13C NMR spectra and prominent bands in the aliphatic stretching region (2800-3000??cm- 1) of FTir spectra, all indicating a highly aliphatic molecular structure. The 13C NMR and FTir data indicate a diterpenoid structure for these resins. There is an abrupt loss of oxygen that occurs at the Lignite A/Subbituminous C stage, which is attributed to a dramatic loss of carboxyl (COOH) from the diterpenoid molecule. This is a new finding in the diagenesis of resins. This important loss in oxygenated functional groups is attributed to a maturation change. Also, there is a progressive loss of exomethylene (CH2) groups with increasing degree of maturation, as shown by both 13C NMR and FTir data. This change has been noted by previous investigators. Exomethylene is absent in the fossil resins from the Eocene high volatile C bituminous coals. This progressive loss is characteristic of Class I resinites. FTir data indicate that the oxygenated functional groups are strong in all the resin samples except the fossil resin from high volatile C bituminous coal. This important change in oxygenated functional groups is attributed to maturation changes. The 13C NMR and FTir data indicate there are minor changes in the Agathis australis resin from the living tree and soil, which suggests that alteration of A. australis resins begins shortly after deposition in the soil for as little as 1000??years. The Morwell

  8. Comparison of the Effects of Two Different Drinks on Microhardness of a Silorane-based Composite Resin.

    PubMed

    Sadat HashemiKamangar, Sedighe; Ghavam, Maryam; Mirkhezri, Zhina; Karazifard, Mohammad Javad

    2015-09-01

    Acidic foods and drinks can erode composite resins. Silorane-based composite is a new low shrinkage composite with higher hydrophobicity which might resist the erosive effect of beverages. The aim of this study was to determine the effects of 100% orange juice and non-alcoholic carbonated beer on microhardness of a silorane-based composite in comparison with two methacrylate-based composite resins. Ninety disc-shaped composite specimens were fabricated of Filtek P90, Filtek Z350 XT Enamel and Filtek Z250 (3M-ESPE) (n=30) and randomly divided into 3 subgroups of 10.Group 1 was immersed in distilled water, group 2 in 100% orange juice, and group 3 in non-alcoholic beer for 3 h/day. Primary, secondary and final Vickers microhardness tests were performed at the beginning of the study and 7 and 28 days later. Surface of 2 specimens in each group was evaluated under scanning electron microscope on day 28. Data were analyzed using repeated measures of ANOVA model (α=0.05). The primary and secondary microhardness of P90 was significantly lower than that of Z350, and Z250 (p< 0.001). Microhardness of Z350 was also lower than that of Z250 (p= 0.002). On day 28, microhardness of P90 was lower than Z250 and Z350 (p< 0.001); however, microhardness values of Z250 and Z350 were not significantly different (p= 0.054). Microhardness of specimens subjected to non-alcoholic beer was significantly lower than that of controls (p= 0.003). Meanwhile, the microhardness value of resins in orange juice was somewhere between the two mentioned values with no significant difference with any of them (p> 0.05). Although 28 days of immersion in 100% orange juice and non-alcoholic beer decreased the microhardness of all specimens, P90 experienced the greatest reduction of microhardness and non-alcoholic beer had the highest effect on reducing microhardness.

  9. Resin embedded multicycle imaging (REMI): a tool to evaluate protein domains.

    PubMed

    Busse, B L; Bezrukov, L; Blank, P S; Zimmerberg, J

    2016-08-08

    Protein complexes associated with cellular processes comprise a significant fraction of all biology, but our understanding of their heterogeneous organization remains inadequate, particularly for physiological densities of multiple protein species. Towards resolving this limitation, we here present a new technique based on resin-embedded multicycle imaging (REMI) of proteins in-situ. By stabilizing protein structure and antigenicity in acrylic resins, affinity labels were repeatedly applied, imaged, removed, and replaced. In principle, an arbitrarily large number of proteins of interest may be imaged on the same specimen with subsequent digital overlay. A series of novel preparative methods were developed to address the problem of imaging multiple protein species in areas of the plasma membrane or volumes of cytoplasm of individual cells. For multiplexed examination of antibody staining we used straightforward computational techniques to align sequential images, and super-resolution microscopy was used to further define membrane protein colocalization. We give one example of a fibroblast membrane with eight multiplexed proteins. A simple statistical analysis of this limited membrane proteomic dataset is sufficient to demonstrate the analytical power contributed by additional imaged proteins when studying membrane protein domains.

  10. Resin embedded multicycle imaging (REMI): a tool to evaluate protein domains

    PubMed Central

    Busse, B. L.; Bezrukov, L.; Blank, P. S.; Zimmerberg, J.

    2016-01-01

    Protein complexes associated with cellular processes comprise a significant fraction of all biology, but our understanding of their heterogeneous organization remains inadequate, particularly for physiological densities of multiple protein species. Towards resolving this limitation, we here present a new technique based on resin-embedded multicycle imaging (REMI) of proteins in-situ. By stabilizing protein structure and antigenicity in acrylic resins, affinity labels were repeatedly applied, imaged, removed, and replaced. In principle, an arbitrarily large number of proteins of interest may be imaged on the same specimen with subsequent digital overlay. A series of novel preparative methods were developed to address the problem of imaging multiple protein species in areas of the plasma membrane or volumes of cytoplasm of individual cells. For multiplexed examination of antibody staining we used straightforward computational techniques to align sequential images, and super-resolution microscopy was used to further define membrane protein colocalization. We give one example of a fibroblast membrane with eight multiplexed proteins. A simple statistical analysis of this limited membrane proteomic dataset is sufficient to demonstrate the analytical power contributed by additional imaged proteins when studying membrane protein domains. PMID:27499335

  11. Effect of repair resin type and surface treatment on the repair strength of polyamide denture base resin.

    PubMed

    Gundogdu, Mustafa; Yanikoglu, Nuran; Bayindir, Funda; Ciftci, Hilal

    2015-01-01

    The purpose of the present study was to evaluate the effects of different repair resins and surface treatments on the repair strength of a polyamide denture base material. Polyamide resin specimens were prepared and divided into nine groups according to the surface treatments and repair materials. The flexural strengths were measured with a 3-point bending test. Data were analyzed with a 2-way analysis of variance, and the post-hoc Tukey test (α=0.05). The effects of the surface treatments on the surface of the polyamide resin were examined using scanning electron microscopy. The repair resins and surface treatments significantly affected the repair strength of the polyamide denture base material (p<0.05); however, no significant differences were observed interaction between the factors (p>0.05). The flexural strength of the specimens repaired with the polyamide resin was significantly higher than that of those repaired with the heat-polymerized and autopolymerizing acrylic resins.

  12. Phosphonic acid based exchange resins

    DOEpatents

    Horwitz, E. Philip; Alexandratos, Spiro D.; Gatrone, Ralph C.; Chiarizia, Ronato

    1995-01-01

    An ion exchange resin for extracting metal ions from a liquid waste stream. An ion exchange resin is prepared by copolymerizing a vinylidene diphosphonic acid with styrene, acrylonitrile and divinylbenzene.

  13. A new resin embedded with chelating motifs of biogenic methionine for the removal of Hg(II) at ppb levels.

    PubMed

    Ali, Shaikh A; Mazumder, Mohammad A J

    2018-05-15

    Cyclopolymerization of N,N-diallylmethionine hydrochloride, derived from the biogenic amino acid methionine, (90 mol%) and cross-linker tetraallylpiperazinium dichloride (10 mol%) in presence of an azo-initiator afforded pH-responsive cross-linked polyzwitterion (CPZ). The structural morphology of the resin (i.e. CPZ) was examined by the BET and FESEM-EDX analyses. The methionine embedded resin demonstrated remarkable efficacies for the removal of Hg(II) ions at ppb levels. A 50 mg-dose of the resin immersed in aqueous medium (18 mL) could reduce the concentration of Hg(II) from 200 and 400 ppb to 1.8 and 4.4 ppb, respectively, within 15 min. The resin has also proven to be remarkably effective in the removal of several toxic and priority metal pollutants from industrial wastewater. The Hg(II) adsorption followed pseudo second-order process with E a of 48.1 kJ mol -1 . The initial rapid adsorption of metal ions and subsequent slower adsorption was attributed to film and intraparticle diffusion, respectively. The SEM-EDX analyses revealed the attachment of Hg(II) ions onto the resin. The favorability of the endothermic adsorption was ensured by the negative ΔGº values. The efficient adsorption/desorption process confirmed the recyclability of the resin. The current resin demonstrated superior metal removal capacities as compared to several other adsorbents in recent works. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Acetylene-chromene terminated resins as high temperature thermosets

    NASA Technical Reports Server (NTRS)

    Godschalx, J. P.; Inbasekaran, M. N.; Bartos, B. R.; Scheck, D. M.; Laman, S. A.

    1990-01-01

    A novel phase transfer catalyzed process for the preparation of propargyl ethers has been developed. The propargyl ethers serve as precursors to a new class of thermosetting resins called acetylene-chromene terminated (ACT) resins. Heat treatment of a solution of propargyl ethers with various catalysts, followed by removal of solvent leads to the ACT resins via partial conversion of the propargyl ether groups to chromenes. This process reduces the energy content of the resin systems and reduces the amount of shrinkage found during cure. Due to the presence of the solvent the process is safe and gives rise to low viscosity products suitable for resin transfer molding and filament winding type applications. Due to the high glass transition temperature, high modulus, and low moisture uptake the cured resins display better than 232 C/wet performance. The thermal stability of the ACT resins in air at 204 C is superior to that of conventional bismaleimide resins. The resins also display excellent electrical properties.

  15. Removal and recovery of vanadium from alkaline steel slag leachates with anion exchange resins.

    PubMed

    Gomes, Helena I; Jones, Ashley; Rogerson, Mike; Greenway, Gillian M; Lisbona, Diego Fernandez; Burke, Ian T; Mayes, William M

    2017-02-01

    Leachable vanadium (V) from steel production residues poses a potential environmental hazard due to its mobility and toxicity under the highly alkaline pH conditions that characterise these leachates. This work aims to test the efficiency of anion exchange resins for vanadium removal and recovery from steel slag leachates at a representative average pH of 11.5. Kinetic studies were performed to understand the vanadium sorption process. The sorption kinetics were consistent with a pseudo-first order kinetic model. The isotherm data cannot differentiate between the Langmuir and Freundlich models. The maximum adsorption capacity (Langmuir value q max ) was 27 mg V g -1 resin. In column anion exchange, breakthrough was only 14% of the influent concentration after passing 90 L of steel slag leachate with 2 mg L -1 V through the column. When eluting the column 57-72% of vanadium was recovered from the resin with 2 M NaOH. Trials on the reuse of the anion exchange resin showed it could be reused 20 times without loss of efficacy, and on average 69% of V was recovered during regeneration. The results document for the first time the use of anion exchange resins to remove vanadium from steel slag leachate. As an environmental contaminant, removal of V from leachates may be an obligation for long-term management requirements of steel slag repositories. Vanadium removal coupled with the recovery can potentially be used to offset long-term legacy treatment costs. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Microhardness of dual-polymerizing resin cements and foundation composite resins for luting fiber-reinforced posts.

    PubMed

    Yoshida, Keiichi; Meng, Xiangfeng

    2014-06-01

    The optimal luting material for fiber-reinforced posts to ensure the longevity of foundation restorations remains undetermined. The purpose of this study was to evaluate the suitability of 3 dual-polymerizing resin cements and 2 dual-polymerizing foundation composite resins for luting fiber-reinforced posts by assessing their Knoop hardness number. Five specimens of dual-polymerizing resin cements (SA Cement Automix, G-Cem LincAce, and Panavia F2.0) and 5 specimens of dual-polymerizing foundation composite resins (Clearfil DC Core Plus and Unifil Core EM) were polymerized from the top by irradiation for 40 seconds. Knoop hardness numbers were measured at depths of 0.5, 2.0, 4.0, 6.0, 8.0, and 10.0 mm at 0.5 hours and 7 days after irradiation. Data were statistically analyzed by repeated measures ANOVA, 1-way ANOVA, and the Tukey compromise post hoc test (α=.05). At both times after irradiation, the 5 resins materials showed the highest Knoop hardness numbers at the 0.5-mm depth. At 7 days after irradiation, the Knoop hardness numbers of the resin materials did not differ significantly between the 8.0-mm and 10.0-mm depths (P>.05). For all materials, the Knoop hardness numbers at 7 days after irradiation were significantly higher than those at 0.5 hours after irradiation at all depths (P<.05). At 7 days after irradiation, the Knoop hardness numbers of the 5 resin materials were found to decrease in the following order: DC Core Plus, Unifil Core EM, Panavia F2.0, SA Cement Automix, and G-Cem LincAce (P<.05). The Knoop hardness number depends on the depth of the cavity, the length of time after irradiation, and the material brand. Although the Knoop hardness numbers of the 2 dual-polymerizing foundation composite resins were higher than those of the 3 dual-polymerizing resin cements, notable differences were seen among the 5 materials at all depths and at both times after irradiation. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry

  17. Composite resins in the 21st century.

    PubMed

    Willems, G; Lambrechts, P; Braem, M; Vanherle, G

    1993-09-01

    Human enamel and dentin should be used as the physiologic standards with which to compare composite resins, especially in the posterior region. The intrinsic surface roughness of composite resins must be equal to or lower than the surface roughness of human enamel on enamel-to-enamel occlusal contact areas (Ra = 0.64 microns). Roughness determines the biologic strength of composite resins. The nanoindentation hardness value of the filler particles (2.91 to 8.84 GPa) must not be higher than that of the hydroxyapatite crystals of human enamel (3.39 GPa). Composite resins intended for posterior use should have a Young's modulus at least equal to, and preferably higher than, that of dentin (18.500 MPa). The compressive strength of enamel (384 MPa) and dentin (297 MPa) and the fracture strength of a natural tooth (molar = 305 MPa; premolar = 248 MPa) offer excellent mechanical standards to select the optimal strength for posterior composite resins. The in vivo occlusal contact area wear rate of composite resins must be comparable to the attritional enamel wear rate (about 39 microns/y) in molars. Differential wear between enamel and composite resin on the same tooth is a new criterion for visualizing and quantifying the wear resistance of composite resins in a biologic way. Posterior resins must have a radiographic opacity that is slightly in excess of that of human enamel (198% Al). Based on these standard criteria, it can be concluded that in the 21st century the ultrafine compact-filled composite resins may be the materials of choice for restoring posterior cavities.

  18. Structure Property Relationships of Biobased Epoxy Resins

    NASA Astrophysics Data System (ADS)

    Maiorana, Anthony Surraht

    The thesis is about the synthesis, characterization, development, and application of epoxy resins derived from sustainable feedstocks such as lingo-cellulose, plant oils, and other non-food feedstocks. The thesis can be divided into two main topics 1) the synthesis and structure property relationship investigation of new biobased epoxy resin families and 2) mixing epoxy resins with reactive diluents, nanoparticles, toughening agents, and understanding co-curing reactions, filler/matrix interactions, and cured epoxy resin thermomechanical, viscoelastic, and dielectric properties. The thesis seeks to bridge the gap between new epoxy resin development, application for composites and advanced materials, processing and manufacturing, and end of life of thermoset polymers. The structures of uncured epoxy resins are characterized through traditional small molecule techniques such as nuclear magnetic resonance, high resolution mass spectrometry, and infrared spectroscopy. The structure of epoxy resin monomers are further understood through the process of curing the resins and cured resins' properties through rheology, chemorheology, dynamic mechanical analysis, tensile testing, fracture toughness, differential scanning calorimetry, scanning electron microscopy, thermogravimetric analysis, and notched izod impact testing. It was found that diphenolate esters are viable alternatives to bisphenol A and that the structure of the ester side chain can have signifi-cant effects on monomer viscosity. The structure of the cured diphenolate based epoxy resins also influence glass transition temperature and dielectric properties. Incorporation of reactive diluents and flexible resins can lower viscosity, extend gel time, and enable processing of high filler content composites and increase fracture toughness. Incorpora-tion of high elastic modulus nanoparticles such as graphene can provide increases in physical properties such as elastic modulus and fracture toughness. The synthesis

  19. Phosphonic acid based exchange resins

    DOEpatents

    Horwitz, E.P.; Alexandratos, S.D.; Gatrone, R.C.; Chiarizia, R.

    1995-09-12

    An ion exchange resin is described for extracting metal ions from a liquid waste stream. An ion exchange resin is prepared by copolymerizing a vinylidene diphosphonic acid with styrene, acrylonitrile and divinylbenzene. 10 figs.

  20. Radioembolization and the Dynamic Role of 90Y PET/CT

    PubMed Central

    Pasciak, Alexander S.; Bourgeois, Austin C.; McKinney, J. Mark; Chang, Ted T.; Osborne, Dustin R.; Acuff, Shelley N.; Bradley, Yong C.

    2014-01-01

    Before the advent of tomographic imaging, it was postulated that decay of 90 Y to the 0+ excited state of 90Zr may result in emission of a positron–electron pair. While the branching ratio for pair-production is small (~32 × 10−6), PET has been successfully used to image 90 Y in numerous recent patients and phantom studies. 90 Y PET imaging has been performed on a variety of PET/CT systems, with and without time-of-flight (TOF) and/or resolution recovery capabilities as well as on both bismuth-germanate and lutetium yttrium orthosilicate (LYSO)-based scanners. On all systems, resolution and contrast superior to bremsstrahlung SPECT has been reported. The intrinsic radioactivity present in LYSO-based PET scanners is a potential limitation associated with accurate quantification of 90 Y. However, intrinsic radioactivity has been shown to have a negligible effect at the high activity concentrations common in 90 Y radioembolization. Accurate quantification is possible on a variety of PET scanner models, with or without TOF, although TOF improves accuracy at lower activity concentrations. Quantitative 90 Y PET images can be transformed into 3-dimensional (3D) maps of absorbed dose based on the premise that the 90 Y activity distribution does not change after infusion. This transformation has been accomplished in several ways, although the most common is with the use of 3D dose-point-kernel convolution. From a clinical standpoint, 90 Y PET provides a superior post-infusion evaluation of treatment technical success owing to its improved resolution. Absorbed dose maps generated from quantitative PET data can be used to predict treatment efficacy and manage patient follow-up. For patients who receive multiple treatments, this information can also be used to provide patient-specific treatment-planning for successive therapies, potentially improving response. The broad utilization of 90 Y PET has the potential to provide a wealth of dose

  1. NITRATE CONVERSION OF HB-LINE REILLEXTM HPQ RESIN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steimke, J.; Williams, M.; Steeper, T.

    Reillex{trademark} HPQ ion exchange resin is used by HB Line to remove plutonium from aqueous streams. Reillex{trademark} HPQ resin currently available from Vertellus Specialties LLC is a chloride ionic form, which can cause stress corrosion cracking in stainless steels. Therefore, HB Line Engineering requested that Savannah River National Laboratory (SRNL) convert resin from chloride form to nitrate form in the Engineering Development Laboratory (EDL). To perform this task, SRNL treated two batches of resin in 2012. The first batch of resin from Reilly Industries Batch 80302MA was initially treated at SRNL in 2001 to remove chloride. This batch of resin,more » nominally 30 liters, has been stored wet in carboys since that time until being retreated in 2012. The second batch of resin from Batch 23408 consisted of 50 kg of new resin purchased from Vertellus Specialties in 2012. Both batches were treated in a column designed to convert resin using downflow of 1.0 M sodium nitrate solution through the resin bed followed by rinsing with deionized water. Both batches were analyzed for chloride concentration, before and after treatment, using Neutron Activation Analysis (NAA). The resin specification [Werling, 2003] states the total chlorine and chloride concentration shall be less than 250 ppm. The resin condition for measuring this concentration is not specified; however, in service the resin would always be fully wet. Measurements in SRNL showed that changing from oven dry resin to fully wet resin, with liquid in the particle interstices but no supernatant, increases the total weight by a factor of at least three. Therefore, concentration of chlorine or chloride expressed as parts per million (ppm) decreases by a factor of three. Therefore, SRNL recommends measuring chlorine concentration on an oven dry basis, then dividing by three to estimate chloride concentration in the fully wet condition. Chloride concentration in the first batch (No.80302MA) was nearly the

  2. Delayed cure bismaleimide resins

    DOEpatents

    Not Available

    1982-08-12

    Prior art polybismaleimides begin to polymerize at or just above the melting point of the monomer. This patent describes new bismaleimide resins which have an increased pot life and provide longer time periods in which the monomer remains fluid. The resins can be polymerized into molded articles with a high uniformity of properties. (DLC)

  3. High-spin europium and gadolinium centers in yttrium-aluminum garnet

    NASA Astrophysics Data System (ADS)

    Vazhenin, V. A.; Potapov, A. P.; Asatryan, G. R.; Uspenskaya, Yu. A.; Petrosyan, A. G.; Fokin, A. V.

    2016-08-01

    Electron-spin resonance spectra of Eu2+ and Gd3+ centers substituting Y3+ ions in single-crystal yttrium-aluminum garnet have been studied and the parameters of their rhombic spin Hamiltonian have been determined. The fine-structure parameters of the above ions have been calculated in the superposition model disregarding changes in the angular coordinates of the ligand environment of the impurity defect thus demonstrating the necessity of taking these changes into account.

  4. 40 CFR 90.114 - Requirement of certification-engine information label.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Standards and Certification Provisions § 90.114 Requirement of certification—engine... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Requirement of certification-engine...

  5. 40 CFR 90.114 - Requirement of certification-engine information label.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Standards and Certification Provisions § 90.114 Requirement of certification—engine... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Requirement of certification-engine...

  6. 40 CFR 90.114 - Requirement of certification-engine information label.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Standards and Certification Provisions § 90.114 Requirement of certification—engine... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Requirement of certification-engine...

  7. 40 CFR 90.114 - Requirement of certification-engine information label.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Standards and Certification Provisions § 90.114 Requirement of certification—engine... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Requirement of certification-engine...

  8. Modeling of process-induced residual stresses and resin flow behavior in resin transfer molded composites with woven fiber mats

    NASA Astrophysics Data System (ADS)

    Golestanian, Hossein

    This research focuses on modeling Resin Transfer Molding process for manufacture of composite parts with woven fiber mats. Models are developed to determine cure dependent stiffness matrices for composites manufactured with two types of woven fiber mats. Five-harness carbon and eight-harness fiberglass mats with EPON 826 resin composites are considered. The models presented here take into account important material/process parameters with emphasis on; (1) The effects of cure-dependent resin mechanical properties, (2) Fiber undulation due to the weave of the fiber fill and warp bundles, and (3) Resin interaction with the fiber bundles at a microscopic scale. Cure-dependent mechanical properties were then used in numerical models to determine residual stresses and deformation in the composite parts. The complete cure cycle was modeled in these analyses. Also the cool down stage after the composite cure was analyzed. The effect of 5% resin shrinkage on residual stresses and deformations was also investigated. In the second part of the study, Finite Element models were developed to simulate mold filling in RTM processes. Resin flow in the fiber mats was modeled as flow through porous media. Physical models were also developed to investigate resin flow behavior into molds of rectangular and irregular shapes. Silicone fluids of 50 and 100 centistoke viscosities as well as EPON 826 epoxy resin were used in the mold filling experiments. The reinforcements consisted of several layers of woven fiberglass and carbon fiber mats. The effects of injection pressure, fluid viscosity, type of reinforcement, and mold geometry on mold filling times were investigated. Fiber mat permeabilities were determined experimentally for both types of reinforcements. Comparison of experimental and numerical resin front positions indicated the importance of edge effects in resin flow behavior in small cavities. The resin front positions agreed well for the rectangular mold geometry.

  9. Physical Properties of Synthetic Resin Materials

    NASA Technical Reports Server (NTRS)

    Fishbein, Meyer

    1939-01-01

    A study was made to determine the physical properties of synthetic resins having paper, canvas, and linen reinforcements, and of laminated wood impregnated with a resin varnish. The results show that commercial resins have moduli of elasticity that are too low for structural considerations. Nevertheless, there do exist plastics that have favorable mechanical properties and, with further development, it should be possible to produce resin products that compare favorably with the light-metal alloys. The results obtained from tests on Compound 1840, resin-impregnated wood, show that this material can stand on its own merit by virtue of a compressive strength four times that of the natural wood. This increase in compressive strength was accomplished with an increase of density to a value slightly below three times the normal value and corrected one of the most serious defects of the natural product.

  10. Electrolytic Deposition and Diffusion of Lithium onto Magnesium-9 Wt Pct Yttrium Bulk Alloy in Low-Temperature Molten Salt of Lithium Chloride and Potassium Chloride

    NASA Astrophysics Data System (ADS)

    Dong, Hanwu; Wu, Yaoming; Wang, Lidong; Wang, Limin

    2009-10-01

    The electrolytic deposition and diffusion of lithium onto bulk magnesium-9 wt pct yttrium alloy cathode in molten salt of 47 wt pct lithium chloride and 53 wt pct potassium chloride at 693 K were investigated. Results show that magnesium-yttrium-lithium ternary alloys are formed on the surface of the cathodes, and a penetration depth of 642 μm is acquired after 2 hours of electrolysis at the cathodic current density of 0.06 A·cm-2. The diffusion of lithium results in a great amount of precipitates in the lithium containing layer. These precipitates are the compound of Mg41Y5, which arrange along the grain boundaries and hinder the diffusion of lithium, and solid solution of yttrium in magnesium. The grain boundaries and the twins of the magnesium-9 wt pct yttrium substrate also have negative effects on the diffusion of lithium.

  11. Flammability screening tests of resins

    NASA Technical Reports Server (NTRS)

    Arhart, R. W.; Farrar, D. G.; Hughes, B. M.

    1979-01-01

    Selected flammability characteristics of glass cloth laminates of thermosetting resins are evaluated. A protocol for the evaluation of the flammability hazards presented by glass cloth laminates of thermosetting resins and the usefulness of that protocol with two laminates are presented. The glass laminates of an epoxy resin, M-751 are evaluated for: (1) determination of smoke generation from the laminates; (2) analysis of products of oxidative degradation of the laminates; (3) determination of minimum oxygen necessary to maintain flaming oxidation; (4) evaluation of toxicological hazards.

  12. Scanning-SQUID investigation of spin-orbit torque acting on yttrium iron garnet devices

    NASA Astrophysics Data System (ADS)

    Rosenberg, Aaron J.; Jermain, Colin L.; Aradhya, Sriharsha V.; Brangham, Jack T.; Nowack, Katja C.; Kirtley, John R.; Yang, Fengyuan; Ralph, Daniel C.; Moler, Kathryn A.

    Successful manipulation of electrically insulating magnets, such as yttrium iron garnet, by by current-driven spin-orbit torques could provide a highly efficient platform for spintronic memory. Compared to devices fabricated using magnetic metals, magnetic insulators have the advantage of the ultra-low magnetic damping and the elimination of shunting currents in the magnet that reduce the torque efficiency. Here, we apply current in the spin Hall metal β-Ta to manipulate the magnetic orientation of micron-sized, electrically-insulating yttrium iron garnet devices. We do not observe spin-torque switching even for applied currents well above the critical current expected in a macrospin switching model. This suggests either inefficient transfer of spin torque at our Ta/YIG interface or a breakdown of the macrospin approximation. This work is supported by FAME, one of six centers of STARnet sponsored by MARCO and DARPA. The SQUID microscope and sensors were developed with support from the NSF-sponsored Center NSF-NSEC 0830228, and from NSF IMR-MIP 0957616.

  13. Biodegradation of resin acid sodium salts

    Treesearch

    Richard W. Hemingway; H. Greaves

    1973-01-01

    The sodium salts of resin acids were readily degraded by microflora from two types of river water and from an activated sewage sludge. A lag phase with little or no resin acid salt degradation but rapid bacterial development occurred which was greatly extended by a decrease in incubation temperature. After this initial lag phase, the resin acid salts were rapidly...

  14. Development of tough, moisture resistant laminating resins

    NASA Technical Reports Server (NTRS)

    Brand, R. A.; Harrison, E. S.

    1982-01-01

    Tough, moisture resistant laminating resins for employment with graphite fibers were developed. The new laminating resins exhibited cost, handleability and processing characteristics equivalent to 394K (250 F) curing epoxies. The laminating resins were based on bisphenol A dicyanate and monofunctional cyanates with hydrophobic substituents. These resins sorb only small quantities of moisture at equilibrium (0.5% or less) with minimal glass transition temperature depression and represent an improvement over epoxies which sorb around 2% moisture at equilibrium. Toughening was accomplished by the precipitation of small diameter particles of butadiene nitrile rubber throughout the resin matrix. The rubber domains act as microcrack termini and energy dissipation sites, allowing increased stress accommodation prior to catastrophic failure. A unique blend of amine terminated butadiene nitrile elastomer (MW 2,000) and a high nitrile content butadiene nitrile rubber yielded the desired resin morphology.

  15. The effect of repeated preheating of dimethacrylate and silorane-based composite resins on marginal gap of class V restorations.

    PubMed

    Alizadeh Oskoee, Parnian; Pournaghi Azar, Fatemeh; Jafari Navimipour, Elmira; Ebrahimi Chaharom, Mohammad Esmaeel; Naser Alavi, Fereshteh; Salari, Ashkan

    2017-01-01

    Background. One of the problems with composite resin restorations is gap formation at resin‒tooth interface. The present study evaluated the effect of preheating cycles of silorane- and dimethacrylate-based composite resins on gap formation at the gingival margins of Class V restorations. Methods. In this in vitro study, standard Class V cavities were prepared on the buccal surfaces of 48 bovine incisors. For restorative procedure, the samples were randomly divided into 2 groups based on the type of composite resin (group 1: di-methacrylate composite [Filtek Z250]; group 2: silorane composite [Filtek P90]) and each group was randomly divided into 2 subgroups based on the composite temperature (A: room temperature; B: after 40 preheating cycles up to 55°C). Marginal gaps were measured using a stereomicroscope at ×40 and analyzed with two-way ANOVA. Inter- and intra-group comparisons were analyzed with post-hoc Tukey tests. Significance level was defined at P < 0.05. Results. The maximum and minimum gaps were detected in groups 1-A and 2-B, respectively. The effects of composite resin type, preheating and interactive effect of these variables on gap formation were significant (P<0.001). Post-hoc Tukey tests showed greater gap in dimethacrylate compared to silorane composite resins (P< 0.001). In each group, gap values were greater in composite resins at room temperature compared to composite resins after 40 preheating cycles (P<0.001). Conclusion. Gap formation at the gingival margins of Class V cavities decreased due to preheating of both composite re-sins. Preheating of silorane-based composites can result in the best marginal adaptation.

  16. The effect of repeated preheating of dimethacrylate and silorane-based composite resins on marginal gap of class V restorations

    PubMed Central

    Alizadeh Oskoee, Parnian; Pournaghi Azar, Fatemeh; Jafari Navimipour, Elmira; Ebrahimi chaharom, Mohammad Esmaeel; Naser Alavi, Fereshteh; Salari, Ashkan

    2017-01-01

    Background. One of the problems with composite resin restorations is gap formation at resin‒tooth interface. The present study evaluated the effect of preheating cycles of silorane- and dimethacrylate-based composite resins on gap formation at the gingival margins of Class V restorations. Methods. In this in vitro study, standard Class V cavities were prepared on the buccal surfaces of 48 bovine incisors. For restorative procedure, the samples were randomly divided into 2 groups based on the type of composite resin (group 1: di-methacrylate composite [Filtek Z250]; group 2: silorane composite [Filtek P90]) and each group was randomly divided into 2 subgroups based on the composite temperature (A: room temperature; B: after 40 preheating cycles up to 55°C). Marginal gaps were measured using a stereomicroscope at ×40 and analyzed with two-way ANOVA. Inter- and intra-group comparisons were analyzed with post-hoc Tukey tests. Significance level was defined at P < 0.05. Results. The maximum and minimum gaps were detected in groups 1-A and 2-B, respectively. The effects of composite resin type, preheating and interactive effect of these variables on gap formation were significant (P<0.001). Post-hoc Tukey tests showed greater gap in dimethacrylate compared to silorane composite resins (P< 0.001). In each group, gap values were greater in composite resins at room temperature compared to composite resins after 40 preheating cycles (P<0.001). Conclusion. Gap formation at the gingival margins of Class V cavities decreased due to preheating of both composite re-sins. Preheating of silorane-based composites can result in the best marginal adaptation. PMID:28413594

  17. Radioembolization as Locoregional Therapy of Hepatic Metastases in Uveal Melanoma Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klingenstein, A., E-mail: annemarie.klingenstein@med.uni-muenchen.de; Haug, A. R.; Zech, C. J.

    2013-02-15

    To retrospectively evaluate the overall survival, safety, and efficacy of metastatic uveal melanoma patients after radioembolization as salvage therapy. Thirteen patients were treated with radioembolization of branches of the hepatic artery with resin-based yttrium-90 ({sup 90}Y)-labelled microspheres. Twelve patients underwent a single application, and 1 patient underwent 4 interventions. Dosages from 644 to 2,450 MBq (mean activity 1,780) were applied. Treatment response was evaluated by way of liver magnetic resonance imaging and computed tomography (CT) as well as whole-body fluorodeoxyglucose positron emission tomography (PET)/CT with evaluation of percentage changes in SUV{sub max} before and at 2-3 months after therapy. Kaplan-Meiermore » analysis was calculated to determine overall survival. Partial remission (PR) was observed in 8 (62 %), stable disease (SD) in 2 (15 %), and progressive disease (PD) in 3 (23 %) patients under terms of standard criteria and PR in 3 (23 %), SD in 3 (23 %), and PD in 7 (54 %) patients according to PET criteria. Neither RECIST nor PET criteria showed a significant difference in predicting overall survival (P = 0.12 and 0.11, respectively). Median survival time after radioembolization was 7 months. No acute toxicity with in-hospital morbidity was observed. One patient developed hepatomegaly, and 1 patient developed gastric ulceration. Throughout follow-up, progression of extrahepatic metastases was observed. Radioembolization may be a promising therapy in uveal melanoma patients with predominant hepatic metastases. At first follow-up, we observed PR or SD in 77 % patients under terms of standard criteria with an acceptable toxicity profile.« less

  18. Assessment of Microleakage of a Composite Resin Restoration in Primary Teeth Following Class III Cavity Preparation Using Er, Cr: YSGG laser: An In Vitro Study

    PubMed Central

    Subramaniam, Priya; Pandey, Annu

    2016-01-01

    Introduction: Marginal seal integrity is important for a successful adhesive dental restoration. Alterations caused by laser irradiation in the enamel and dentin surface can affect the marginal integrity of adhesive restorations. The aim of this study was to evaluate the microleakage of a composite resin restoration in primary teeth following laser irradiation of enamel and dentin. Methods: Forty freshly extracted sound human primary maxillary and mandibular anterior teeth were used in this study. The teeth were randomly divided into two groups (I and II), with 20 teeth in each. In group I, proximal cavities (Class III) were prepared using an airotor hand –piece and diamond bur. The cavities were etched for 15 seconds with 35% phosphoric acid gel, rinsed with water for 15 seconds, air dried and a bonding agent was applied onto the cavity surfaces and light cured for 20 seconds. The cavities were restored with composite resin and light cured for 40 seconds. In group II, proximal (Class III) cavities were prepared using Erbium, Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) (Er,Cr:YSGG) (Biolaseiplus, wave length 2.78 μm). The cavity was then rinsed, air dried and without etching, a bonding agent was applied and light cured for 20 seconds. The cavities were restored in the same manner as that of group I. The treated teeth were mounted on acrylic resin blocks and were subjected to a thermocycling regimen. Following, the teeth were immersed in 2% methylene blue for 24 hours. The teeth were sectioned longitudinally in a bucco-lingual direction using a diamond disc at slow speed. The sections of all the groups were examined under a stereomicroscope for micro-leakage. Results: The mean scores for microleakage in group I was 1.95 ± 1.31 and in group II it was 1.4 ± 1.27. There was no significant difference between the two groups (P = 0.882). Conclusion: No significant difference in microleakage was noticed between the composite resin bonded to lased enamel and

  19. Epoxy hydantoins as matrix resins

    NASA Technical Reports Server (NTRS)

    Weiss, J.

    1983-01-01

    Tensile strength and fracture toughness of castings of the hydantoin resins cured with methylenedianiline are significantly higher than MY 720 control castings. Water absorption of an ethyl, amyl hydantoin formulation is 2.1 percent at equilibrium and Tg's are about 160 C, approximately 15 deg below the final cure temperature. Two series of urethane and ester-extended hydantoin epoxy resins were synthesized to determine the effect of crosslink density and functional groups on properties. Castings cured with methylenedianiline or with hexahydrophthalic anhydride were made from these compounds and evaluated. The glass transition temperatures, tensile strengths and moduli, and fracture toughness values were all much lower than that of the simple hydantoin epoxy resins. Using a methylene bishydantoin epoxy with a more rigid structure gave brittle, low-energy fractures, while a more flexible, ethoxy-extended hydantoin epoxy resin gave a very low Tg.

  20. Commercial Ion Exchange Resin Vitrification in Borosilicate Glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cicero-Herman, C.A.; Workman, P.; Poole, K.

    1998-05-01

    Bench-scale studies were performed to determine the feasibility of vitrification treatment of six resins representative of those used in the commercial nuclear industry. Each resin was successfully immobilized using the same proprietary borosilicate glass formulation. Waste loadings varied from 38 to 70 g of resin/100 g of glass produced depending on the particular resin, with volume reductions of 28 percent to 68 percent. The bench-scale results were used to perform a melter demonstration with one of the resins at the Clemson Environmental Technologies Laboratory (CETL). The resin used was a weakly acidic meth acrylic cation exchange resin. The vitrification processmore » utilized represented a approximately 64 percent volume reduction. Glass characterization, radionuclide retention, offgas analyses, and system compatibility results will be discussed in this paper.« less

  1. Grafted methylenediphosphonate ion exchange resins

    DOEpatents

    Trochimcznk, Andrzej W.; Gatrone, Ralph C.; Alexandratos, Spiro; Horwitz, E. Philip

    1998-01-27

    An ion exchange resin is disclosed that is comprised of an insoluble copolymer onto which are grafted pendent groups that provide 1.0 to about 10 mmol/g dry weight phosphorous. The pendent groups have the formula ##STR1## wherein R is hydrogen, a cation or mixtures thereof; and R.sup.1 is hydrogen or an C.sub.1 -C.sub.2 alkyl group. The resin also contains zero to about 5 mmol/g dry weight of pendent aromatic sulfonate groups. Processes for making and using an ion exchange-resin are also disclosed.

  2. Grafted methylenediphosphonate ion exchange resins

    DOEpatents

    Trochimcznk, Andrzej W.; Gatrone, Ralph C.; Alexandratos, Spiro; Horwitz, E. Philip

    1997-01-01

    An ion exchange resin is disclosed that is comprised of an insoluble copolymer onto which are grafted pendent groups that provide 1.0 to about 10 mmol/g dry weight phosphorous. The pendent groups have the formula ##STR1## wherein R is hydrogen, a cation or mixtures thereof; and R.sup.1 is hydrogen or an C.sub.1 -C.sub.2 alkyl group. The resin also contains zero to about 5 mmol/g dry weight of pendent aromatic sulfonate groups. Processes for making and using an ion exchange resin are also disclosed.

  3. Microtensile bond strength of indirect resin composite to resin-coated dentin: interaction between diamond bur roughness and coating material.

    PubMed

    Kameyama, Atsushi; Oishi, Takumi; Sugawara, Toyotarou; Hirai, Yoshito

    2009-02-01

    This aim of this study was to determine the effect of type of bur and resin-coating material on microtensile bond strength (microTBS) of indirect composite to dentin. Dentin surfaces were first ground with two types of diamond bur and resin-coated using UniFil Bond (UB) or Adper Single Bond (SB), and then bonded to a resin composite disc for indirect restoration with adhesive resin cement. After storage for 24 hr in distilled water at 37 degrees C, microTBS was measured (crosshead speed 1 mm/min). When UB was applied to dentin prepared using the regular-grit diamond bur, microTBS was significantly lower than that in dentin prepared using the superfine-grit bur. In contrast, no significant difference was found between regular-grit and superfine-grit bur with SB. However, more than half of the superfine-grit specimens failed before microTBS testing. These results indicate that selection of bur type is important in improving the bond strength of adhesive resin cement between indirect resin composite and resin-coated dentin.

  4. Neodymium:yttrium-aluminum-garnet laser fusion of endarterectomy flaps.

    PubMed

    Humphrey, P W; Slocum, M M; Loy, T S; Silver, D

    1995-07-01

    This study evaluated the efficacy of neodymium:yttrium-aluminum-garnet laser welding of flaps in canine arteries and in securing the distal flap during human carotid endarterectomy. Endarterectomy flaps were created in both common carotid and both common femoral arteries in 12 dogs. The flaps were repaired with either the neodymium:yttrium-aluminum-garnet laser or with 6-0 polypropylene sutures. The arteries were removed after duplex scanning at either 7 or 28 days. Eighteen high carotid endarterectomy flaps in 16 patients have been subsequently secured with the laser welding technique. Laser repairs (125 +/- 19 joule) of the canine arteries were completed more quickly than suture repairs (mean 25 seconds vs 135 seconds, respectively; p < 0.04). Duplex ultrasonography revealed no discernable differences between the two groups of arteries. Arteries studied at 7 days revealed three microscopic flaps (two suture, one laser), more subintimal fibroblastic proliferation in suture than laser-repaired carotid arteries (3: 1, p = 0.0530), and similar amounts of inflammation in suture- and laser-repaired arteries. Arteries studied at 28 days revealed one microscopic intimal flap (suture-repaired); equal fibroblastic and inflammatory responses in suture- and laser-repaired vessels; and no evidence of laser thermal injury. Eighteen carotid endarterectomy flaps have been successfully fused with no immediate or long-term complications in 16 patients (follow-up of 0 to 24 months). Laser fusion appears to be a safe and effective method for securing distal carotid endarterectomy flaps.

  5. Effect of Energy Drinks on Discoloration of Silorane and Dimethacrylate-Based Composite Resins.

    PubMed

    Ahmadizenouz, Ghazaleh; Esmaeili, Behnaz; Ahangari, Zohreh; Khafri, Soraya; Rahmani, Aghil

    2016-08-01

    This study aimed to assess the effects of two energy drinks on color change (ΔE) of two methacrylate-based and a silorane-based composite resin after one week and one month. Thirty cubic samples were fabricated from Filtek P90, Filtek Z250 and Filtek Z350XT composite resins. All the specimens were stored in distilled water at 37°C for 24 hours. Baseline color values (L*a*b*) of each specimen were measured using a spectrophotometer according to the CIEL*a*b* color system. Ten randomly selected specimens from each composite were then immersed in the two energy drinks (Hype, Red Bull) and artificial saliva (control) for one week and one month. Color was re-assessed after each storage period and ΔE values were calculated. The data were analyzed using the Kruskal Wallis and Mann-Whitney U tests. Filtek Z250 composite showed the highest ΔE irrespective of the solutions at both time points. After seven days and one month, the lowest ΔE values were observed in Filtek Z350XT and Filtek P90 composites immersed in artificial saliva, respectively. The ΔE values of Filtek Z250 and Z350XT composites induced by Red Bull and Hype energy drinks were not significantly different. Discoloration of Filtek P90 was higher in Red Bull energy drink at both time points. Prolonged immersion time in all three solutions increased ΔE values of all composites. However, the ΔE values were within the clinically acceptable range (<3.3) at both time points.

  6. Urea-formaldehyde resins: production, application, and testing

    NASA Astrophysics Data System (ADS)

    Nuryawan, A.; Risnasari, I.; Sucipto, T.; Heri Iswanto, A.; Rosmala Dewi, R.

    2017-07-01

    Urea-formaldehyde (UF) resin, one of the most important formaldehyde resin adhesives, is a polymeric condensation product of formaldehyde with urea, and being widely used for the manufacture of wood-based composite panels, such as plywood, particleboard, and fiberboard. In spite of its benefits such as fast curing, good performance in the panels (colorless), and lower cost; formaldehyde emission (FE) originated from either UF resin itself or composite products bonded by UF resins is considered a critical drawback as it affects human health particularly in indoor environment. In order to reduce the FE, lowering formaldehyde/urea (F/U) mole ratio in the synthesis of the UF resin was done. In this study, synthesis of UF resins was carried out following the conventional alkaline-acid two-step reaction with a second addition of urea, resulting in F/U mole ratio around 1.0, namely 0.95; 1.05, and 1.15. The UF resins produced were used as binder for particleboard making. The board was manufactured in the laboratory using shaving type particle of Gmelina wood, 8% UF resin based on oven dry particle, and 1% NH4Cl (20%wt) as hardener for the resin. The target of the thickness was 10 mm and the dimension was 25 cm x 25 cm. The resulted particleboard then was evaluated the physical and the mechanical properties by Japanese Industrial Standard (JIS) A 5908 (2003). Further, the resulted particleboard also was used for the mice cage’s wall in order to mimic the real living environment. After four weeks exposure in the cages, the mice then were evaluated their mucous organs as well as their blood. The experiment results were as follows: 1) It was possible to synthesis UF resins with low F/U mole ratio; 2) However, the particleboard bonded UF resins with low F/U mole ratio showed poor properties, particularly on the thickness swelling and modulus of elasticity; 3) There was no significant differences among the mucous organs of the mice after a month exposure FE originated from

  7. 21 CFR 175.270 - Poly(vinyl fluoride) resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Poly(vinyl fluoride) resins. 175.270 Section 175... Substances for Use as Components of Coatings § 175.270 Poly(vinyl fluoride) resins. Poly(vinyl fluoride... the purpose of this section, poly(vinyl fluoride) resins consist of basic resins produced by the...

  8. 21 CFR 175.270 - Poly(vinyl fluoride) resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Poly(vinyl fluoride) resins. 175.270 Section 175... Substances for Use as Components of Coatings § 175.270 Poly(vinyl fluoride) resins. Poly(vinyl fluoride... the purpose of this section, poly(vinyl fluoride) resins consist of basic resins produced by the...

  9. Antibacterial and antibiofilm properties of yttrium fluoride nanoparticles

    PubMed Central

    Lellouche, Jonathan; Friedman, Alexandra; Gedanken, Aharon; Banin, Ehud

    2012-01-01

    Antibiotic resistance has prompted the search for new agents that can inhibit bacterial growth. Moreover, colonization of abiotic surfaces by microorganisms and the formation of biofilms is a major cause of infections associated with medical implants, resulting in prolonged hospitalization periods and patient mortality. In this study we describe a water-based synthesis of yttrium fluoride (YF3) nanoparticles (NPs) using sonochemistry. The sonochemical irradiation of an aqueous solution of yttrium (III) acetate tetrahydrate [Y(Ac)3 · (H2O)4], containing acidic HF as the fluorine ion source, yielded nanocrystalline needle-shaped YF3 particles. The obtained NPs were characterized by scanning electron microscopy and X-ray elemental analysis. NP crystallinity was confirmed by electron and powder X-ray diffractions. YF3 NPs showed antibacterial properties against two common bacterial pathogens (Escherichia coli and Staphylococcus aureus) at a μg/mL range. We were also able to demonstrate that antimicrobial activity was dependent on NP size. In addition, catheters were surface modified with YF3 NPs using a one-step synthesis and coating process. The coating procedure yielded a homogeneous YF3 NP layer on the catheter, as analyzed by scanning electron microscopy and energy dispersive spectroscopy. These YF3 NP-modified catheters were investigated for their ability to restrict bacterial biofilm formation. The YF3 NP-coated catheters were able to significantly reduce bacterial colonization compared to the uncoated surface. Taken together, our results highlight the potential to further develop the concept of utilizing these metal fluoride NPs as novel antimicrobial and antibiofilm agents, taking advantage of their low solubility and providing extended protection. PMID:23152681

  10. Chemoviscosity modeling for thermosetting resins, 2

    NASA Technical Reports Server (NTRS)

    Hou, T. H.

    1985-01-01

    A new analytical model for simulating chemoviscosity of thermosetting resin was formulated. The model is developed by modifying the Williams-Landel-Ferry (WLF) theory in polymer rheology for thermoplastic materials. By assuming a linear relationship between the glass transition temperature and the degree of cure of the resin system under cure, the WLF theory can be modified to account for the factor of reaction time. Temperature dependent functions of the modified WLF theory constants were determined from the isothermal cure data of Lee, Loos, and Springer for the Hercules 3501-6 resin system. Theoretical predictions of the model for the resin under dynamic heating cure cycles were shown to compare favorably with the experimental data reported by Carpenter. A chemoviscosity model which is capable of not only describing viscosity profiles accurately under various cure cycles, but also correlating viscosity data to the changes of physical properties associated with the structural transformations of the thermosetting resin systems during cure was established.

  11. 21 CFR 177.2430 - Polyether resins, chlorinated.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyether resins, chlorinated. 177.2430 Section 177... Components of Articles Intended for Repeated Use § 177.2430 Polyether resins, chlorinated. Chlorinated..., in accordance with the following prescribed conditions: (a) The chlorinated polyether resins are...

  12. Chemical modification of protein a chromatography ligands with polyethylene glycol. II: Effects on resin robustness and process selectivity.

    PubMed

    Weinberg, Justin; Zhang, Shaojie; Kirkby, Allison; Shachar, Enosh; Carta, Giorgio; Przybycien, Todd

    2018-04-20

    We have proposed chemical modification of Protein A (ProA) chromatography ligands with polyethylene glycol (PEGylation) as a strategy to increase the resin selectivity and robustness by providing the ligand with a steric repulsion barrier against non-specific binding. Here, we report on robustness and selectivity benefits for Repligen CaptivA PriMAB resin with ligands modified with 5.2 kDa and 21.5 kDa PEG chains, respectively. PEGylation of ProA ligands allowed the resin to retain a higher percentage of static binding capacity relative to the unmodified resin upon digestion with chymotrypsin, a representative serine protease. The level of protection against digestion was independent of the PEG molecular weight or modification extent for the PEGylation chemistry used. Additionally, PEGylation of the ligands was found to decrease the level of non-specific binding of fluorescently labeled bovine serum albumin (BSA) aggregates to the surface of the resin particles as visualized via confocal laser scanning microscopy (CLSM). The level of aggregate binding decreased as the PEG molecular weight increased, but increasing the extent of modification with 5.2 kDa PEG chains had no effect. Further examination of resin particles via CLSM confirmed that the PEG chains on the modified ligands were capable of blocking the "hitchhiking" association of BSA, a mock contaminant, to an adsorbed mAb that is prone to BSA binding. Ligands modified with 21.5 kDa PEG chains were effective at blocking the association, while ligands modified with 5.2 kDa PEG chains were not. Finally, ligands with 21.5 kDa PEG chains increased the selectivity of the resin against host cell proteins (HCPs) produced by Chinese Hamster Ovary (CHO) cells by up to 37% during purification of a monoclonal antibody (mAb) from harvested cell culture fluid (HCCF) using a standard ProA chromatography protocol. The combined work suggests that PEGylating ProA chromatography media is a viable pathway for

  13. Melamine-modified urea formaldehyde resin for bonding particleboards

    Treesearch

    Chung-Yun Hse; Feng Fu; Hui Pan

    2008-01-01

    For the development of a cost-effective melamine-modified urea formaldehyde resin (MUF), the study evaluated the effects of reaction pH and melamine content on resin properties and bond performance of the MUF resin adhesive systems. Eight resins, each with three replicates, were prepared in a factorial experiment that included two formulation variables: two reaction...

  14. Does ErbiumiYttrium-Aluminum-Garnet Laser to Enamel improve the Performance of Etch-and-rinse and Universal Adhesives?

    PubMed

    De Jesus Tavarez, Rudys R; Rodrigues, Lorrany Lc; Diniz, Ana C; Lage, Lucas M; Torres, Carlos Rg; Bandeca, Matheus C; Firoozmand, Leily M

    2018-03-01

    This study aims to evaluate the effect of erbium: Yttrium-aluminum-garnet (Er:YAG) laser irradiation on the enamel microshear bond strength (μSBS), followed by the utilization of etch-and-rinse and universal adhesive systems. A total of 32 molars were sectioned in the mesiodistal direction producing 64 samples that were randomized into two groups (n = 32): single bond 2 (SB2) (etch-and-rinse system; 3M), SB universal (SBU) (universal etching system; The SB2 and SBU groups were then divided into two subgroups (n = 16): (i) enamel was irradiated with an Er:YAG laser (λ = 2.94 μm, 60 mJ, 10 Hz), and (ii) enamel served as a control. The samples were restored with TPH3 (Dentsply), stored in artificial saliva for 24 hours, and subjected to a micro-shear test. Kruskal-Wallis (p < 0.05) and Mann-Whitney U tests indicated no significant differences in uSBS between the groups, and the fractures were predominately at the resin-enamel interface. The previous irradiation of enamel with Er:YAG laser does not interfere with the performance of simplified two-step etch-and-rinse and universal adhesive systems. The increasing use of Er:YAG laser is important to evaluate the influence of this irradiation on the adhesion of restorative materials. Thus, to obtain the longevity of the restorative procedures, it is necessary to know the result of the association of the present adhesive systems to the irradiated substrate.

  15. Thermally stable laminating resins

    NASA Technical Reports Server (NTRS)

    Jones, R. J.; Vaughan, R. W.; Burns, E. A.

    1972-01-01

    Improved thermally stable laminating resins were developed based on the addition-type pyrolytic polymerization. Detailed monomer and polymer synthesis and characterization studies identified formulations which facilitate press molding processing and autoclave fabrication of glass and graphite fiber reinforced composites. A specific resin formulation, termed P10P was utilized to prepare a Courtaulds HMS reinforced simulated airfoil demonstration part by an autoclave molding process.

  16. Electrically conductive resinous bond and method of manufacture

    DOEpatents

    Snowden, T.M. Jr.; Wells, B.J.

    1985-01-01

    A method of bonding elements together with a bond of high strength and good electrical conductivity which comprises: applying an unfilled polyimide resin between surfaces of the elements to be bonded, heat treating said unfilled polyimide resin in stages between a temperature range of about 40 to 365/sup 0/C to form a strong adhesive bond between said elements, applying a metal-filled polyimide resin overcoat between said elements so as to provide electrical connection therebetween, and heat treating said metal-filled polyimide resin with substantially the same temperature profile as the unfilled polyimide resin. The present invention is also concerned with an adhesive, resilient, substantially void free bonding combination for providing a high strength, electrically conductive adhesive attachment between electrically conductive elements which comprises a major amount of an unfilled polyimide resin and a minor amount of a metal-filled polyimide resin.

  17. Electrically conductive resinous bond and method of manufacture

    DOEpatents

    Snowden, Jr., Thomas M.; Wells, Barbara J.

    1987-01-01

    A method of bonding elements together with a bond of high strength and good electrical conductivity which comprises: applying an unfilled polyimide resin between surfaces of the elements to be bonded, heat treating said unfilled polyimide resin in stages between a temperature range of about 40.degree. to 365.degree. C. to form a strong adhesive bond between said elements, applying a metal-filled polyimide resin overcoat between said elements so as to provide electrical connection therebetween, and heat treating said metal-filled polyimide resin with substantially the same temperature profile as the unfilled polyimide resin. The present invention is also concerned with an adhesive, resilient, substantially void free bonding combination for providing a high strength, electrically conductive adhesive attachment between electrically conductive elements which comprises a major amount of an unfilled polyimide resin and a minor amount of a metal-filled polyimide resin.

  18. Grafted methylenediphosphonate ion exchange resins

    DOEpatents

    Trochimcznk, A.W.; Gatrone, R.C.; Alexandratos, S.; Horwitz, E.P.

    1997-04-08

    An ion exchange resin is disclosed that is comprised of an insoluble copolymer onto which are grafted pendent groups that provide 1.0 to about 10 mmol/g dry weight phosphorus. The pendent groups have the formula as shown in the patent wherein R is hydrogen, a cation or mixtures thereof; and R{sup 1} is hydrogen or an C{sub 1}-C{sub 2} alkyl group. The resin also contains zero to about 5 mmol/g dry weight of pendent aromatic sulfonate groups. Processes for making and using an ion exchange resin are also disclosed.

  19. 49 CFR 173.165 - Polyester resin kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Polyester resin kits. 173.165 Section 173.165... Polyester resin kits. (a) Except for transportation by aircraft, polyester resin kits consisting of a base... will not interact dangerously in the event of leakage. (b) For transportation by aircraft, polyester...

  20. 21 CFR 177.2430 - Polyether resins, chlorinated.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Polyether resins, chlorinated. 177.2430 Section... as Components of Articles Intended for Repeated Use § 177.2430 Polyether resins, chlorinated. Chlorinated polyether resins may be safely used as articles or components of articles intended for repeated...

  1. 21 CFR 177.2510 - Polyvinylidene fluoride resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Polyvinylidene fluoride resins. 177.2510 Section... as Components of Articles Intended for Repeated Use § 177.2510 Polyvinylidene fluoride resins. Polyvinylidene fluoride resins may be safely used as articles or components of articles intended for repeated use...

  2. 21 CFR 177.2510 - Polyvinylidene fluoride resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Polyvinylidene fluoride resins. 177.2510 Section... as Components of Articles Intended for Repeated Use § 177.2510 Polyvinylidene fluoride resins. Polyvinylidene fluoride resins may be safely used as articles or components of articles intended for repeated use...

  3. 21 CFR 177.2510 - Polyvinylidene fluoride resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Polyvinylidene fluoride resins. 177.2510 Section... as Components of Articles Intended for Repeated Use § 177.2510 Polyvinylidene fluoride resins. Polyvinylidene fluoride resins may be safely used as articles or components of articles intended for repeated use...

  4. 21 CFR 177.2510 - Polyvinylidene fluoride resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyvinylidene fluoride resins. 177.2510 Section... as Components of Articles Intended for Repeated Use § 177.2510 Polyvinylidene fluoride resins. Polyvinylidene fluoride resins may be safely used as articles or components of articles intended for repeated use...

  5. 40 CFR 721.4380 - Modified hydrocarbon resin.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Modified hydrocarbon resin. 721.4380... Substances § 721.4380 Modified hydrocarbon resin. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as a modified hydrocarbon resin (P-91-1418) is...

  6. Heat generated by Er:YAG laser in the pulp chamber of teeth submitted to removal of dental tissue and composite resin

    NASA Astrophysics Data System (ADS)

    Zanin, Fatima; Brugnera, Aldo, Jr.; Pecora, Jesus D.; Pinheiro, Antonio; Spano, Julio; Barbin, Eduardo; Marchesan, Melissa A.

    2004-05-01

    The knowledge about and control of thermal energy produced by Er:YAG laser after irradiating hard dental tissues and compound resin is important because the pulp, like all vital biological tissue, has a certain capacity for supporting stimulus. The objective of this study was to analyze the thermal variation generated by Er:YAG laser (λ=2.94μm) during the preparation of a Class I cavity in the dental structure and in the removal of microhybrid Z100 (3M) compound resin. An evaluation was made of 30 maxillary human pre-molar teeth from the bank of the Endodontic Laboratory Center of Ribeirao Preto Dental School, Brasil. The sample was divided into 6 groups of 5 teeth each: Group 1, preparation of Class I cavity with Er:YAG laser (350mJ, 3Hz, 343 impulses, 120J, 113 seconds); Group 2, preparation of Class I cavity with Er:YAG laser (350mJ, 4Hz, 343 impulses, 120J, 81 seconds); Group 3, preparation of Class I cavity with Er:YAG laser (350mJ, 6Hz, 343 impulses, 120J, 58 seconds); Group 4, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 3Hz, 258 impulses, 90J, 85 seconds); Group 5, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 4Hz, 258 impulses, 90J, 67 seconds); Group 6, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 6Hz, 258 impulses, 42 seconds). The laser used was KaVo Key 2 (Biberach, Germany), λ=2,94μm, P=3 Watts, pulse duration of 250μs, with air-water cooling. The increase in temperature during dental preparation and the removal of the compound resin was evaluated by means of a Tektronix DMM916 Thermocouple (Consitec, Brasil). The results showed that the application of laser for the removal of the hard dental tissues and for the removal of compound resins with the pulse frequencies 3, 4 and 6 Hz did not generate heating greater than 3.1°C and remained within the histopathological limits permitted for pulp tissue (5.5°C) and there was a significant statistical

  7. Evaluation of the bond strength of resin cements used to lute ceramics on laser-etched dentin.

    PubMed

    Giray, Figen Eren; Duzdar, Lale; Oksuz, Mustafa; Tanboga, Ilknur

    2014-07-01

    The purpose of this study was to investigate the shear bond strength (SBS) of two different adhesive resin cements used to lute ceramics on laser-etched dentin. Erbium, chromium: yttrium, scandium, gallium, garnet (Er,Cr:YSGG) laser irradiation has been claimed to improve the adhesive properties of dentin, but results to date have been controversial, and its compatibility with existing adhesive resin cements has not been conclusively determined. Two adhesive cements, one "etch-and-rinse" [Variolink II (V)] and one "self-etch" [Clearfil Esthetic Cement (C)] luting cement, were used to lute ceramic blocks (Vita Celay Blanks, Vita) onto dentin surfaces. In total, 80 dentin specimens were distributed randomly into eight experimental groups according to the dentin surface-etching technique used Er,Cr:YSGG laser and Er:YAG laser: (1) 37% orthophosphoric acid+V (control group), (2) Er,Cr:YSGG laser+V, (3) Er,Cr:YSGG laser+acid+V, (4) Er:YAG laser+V, (5) Er:YAG laser+acid+V, (6) C, (7) Er,Cr:YSGG laser+C, and (8) Er:YAG laser+C. Following these applications, the ceramic discs were bonded to prepared surfaces and were shear loaded in a universal testing machine until fracture. SBS was recorded for each group in MPa. Shear test values were evaluated statistically using the Mann-Whitney U test. No statistically significant differences were evident between the control group and the other groups (p>0.05). The Er,Cr:YSGG laser+A+V group demonstrated significantly higher SBS than did the Er,Cr:YSGG laser+V group (p=0.034). The Er,Cr:YSGG laser+C and Er:YAG laser+C groups demonstrated significantly lower SBS than did the C group (p<0.05). Dentin surfaces prepared with lasers may provide comparable ceramic bond strengths, depending upon the adhesive cement used.

  8. Chemoviscosity modeling for thermosetting resins

    NASA Technical Reports Server (NTRS)

    Tiwari, S. N.; Hou, T. H.; Bai, J. M.

    1985-01-01

    A chemoviscosity model, which describes viscosity rise profiles accurately under various cure cycles, and correlates viscosity data to the changes of physical properties associated with structural transformations of the thermosetting resin system during cure, was established. Work completed on chemoviscosity modeling for thermosetting resins is reported.

  9. The effect of disinfectant solutions on the hardness of acrylic resin denture teeth.

    PubMed

    Pavarina, A C; Vergani, C E; Machado, A L; Giampaolo, E T; Teraoka, M T

    2003-07-01

    This investigation studied the effects of disinfectant solutions on the hardness of acrylic resin denture teeth. The occlusal surfaces of 64 resin denture teeth were ground flat with abrasives up to 400-grit silicon carbide paper. Measurements were made after polishing and after the specimens were stored in water at 37 degrees C for 48 h. The specimens were then divided into four groups and immersed in chemical disinfectants (4% chlorhexidine; 1% sodium hypochlorite and sodium perborate) for 10 min. The disinfection methods were performed twice to simulate clinical conditions and hardness measurements were made. Specimens tested as controls were immersed in water during the same disinfection time. Eight specimens were produced for each group. After desinfection procedures, testing of hardness was also performed after the samples were stored at 37 degrees C for 7, 30, 60, 90 and 120 days. Data were analysed using two-way analysis of variance (anova) and Tukey's test at 95% confidence level. According to the results, no significant differences were found between materials and immersion solutions (P > 0.05). However, a continuous decrease in hardness was noticed after ageing (P < 0.05). It was conclude that the surfaces of both acrylic resin denture teeth softened upon immersion in water regardless the disinfecting solution.

  10. Radiopacity of 28 Composite Resins for Teeth Restorations.

    PubMed

    Raitz, Ricardo; Moruzzi, Patrizia Dubinskas; Vieira, Glauco; Fenyo-Pereira, Marlene

    2016-02-01

    Radiopacity is a fundamental requisite to check marginal adaptation of restorations. Our objective was to assess the radiopacity of 28 brands of light-cured composite resins and compare their radiopacity with that of enamel, dentin, and aluminum of equivalent thickness. Composite resin disks (0.2, 0.5, and 1 mm) were radiographed by the digital method, together with an aluminum penetrometer and a human tooth equivalent tooth section. The degree of radiopacity of each image was quantified using digital image processing. Wilcoxon nonparametric test was used for comparison of the mean thickness of each material. All of the materials tested had an equal or greater radiopacity than that of aluminum of equivalent thickness. Similar results for enamel were found with the exception of Durafill, which was less radiopaque than enamel (p < 0.05). All the specimens were more radiopaque than dentin, except for P90 (which was equally radiopaque) and Durafill (which was less radiopaque). The thickness of the specimens may influence the similarity to the enamel's radiopacity. All of the composite resins comply with specification #27 of the American Dental Association. The radiopacity of Amelogen Plus, Aph, Brilhiante, Charisma, Concept Advanced, Evolux X, Exthet X, Inten S, Llis, Master Fill, Natural Look, Opallis, P60, Tetric, Tph, Z100, and Z250 was significantly higher than that of enamel (p < 0.05). With these composites, it is possible to observe the boundaries between restoration and tooth structure, thus allowing clinicians to establish the presence of microleakage or restoration gap. Suitable radiopacity is an essential requisite for good-quality esthetic restorative materials. We demonstrate that only some composites have the sufficient radiopacity to observe the boundaries between restoration and tooth structure, which is the main cause of restoration failure.

  11. Selection of UV Resins for Nanostructured Molds for Thermal-NIL.

    PubMed

    Jia, Zheng; Choi, Junseo; Park, Sunggook

    2018-06-18

    Nanoimprint molds made of soft polymeric materials have advantages of low demolding force and low fabrication cost over Si or metal-based hard molds. However, such advantages are often sacrificed by their reduced replication fidelity associated with the low mechanical strength. In this paper, we studied replication fidelity of different UV-resin molds copied from a Si master mold via UV nanoimprint lithography (NIL) and their thermal imprinting performance into a thermoplastic polymer. Four different UV resins were studied: two were high surface energy UV resins based on tripropyleneglycol diacrylate (TPGDA resin) and polypropyleneglycol diacrylate (PPGDA resin), and the other two were commercially available, low surface energy poly-urethane acrylate (PUA resin) and fluorine-containing (MD 700) UV resins. The replication fidelity among the four UV-resins during UV nanoimprint lithograph from a Si master with sharp nanostructures was in the increasing order of (poorest) PUA resin < MD 700 < PPGDA resin < TPGDA resin (best). The results show that the high surface energy and small monomer size are keys to achieving good UV resin filling into sharp nanostructures over the viscosity of the resin solution. When the four UV-resin molds were used for thermal-NIL into a thermoplastic polymer, the replication fidelity was in the increasing order of (poorest) MD 700 < TPGDA resin < PUA resin (best), which follows the same order of their Young's moduli. Our results indicate that the selection of an appropriate UV resin for NIL molds requires consideration of the replication fidelities in the mold fabrication and the subsequent thermal-NIL into thermoplastic polymers. © 2018 IOP Publishing Ltd.

  12. Maintaining High Strength in Mg-LPSO Alloys with Low Yttrium Content Using Severe Plastic Deformation.

    PubMed

    Garces, Gerardo; Cabeza, Sandra; Barea, Rafael; Pérez, Pablo; Adeva, Paloma

    2018-05-05

    Alternative processing routes such as powder metallurgy, the extrusion of recycled chips, or equal channel angular pressing (ECAP) have been considered for effective methods of maintaining the high mechanical strength of Mg-Y-Zn alloys containing long-period stacking ordered structures with respect to the alloy processed by the conventional extrusion of as-cast ingots with the advantage of minimizing the yttrium content. A yield stress similar to that found for extruded Mg 97 Y₂Zn₁ alloy can be attained with only half of the usual yttrium and zinc additions thanks to the grain refinement induced by ECAP processing. The properties of Mg 98.5 Y₁Zn 0.5 subjected to ECAP are maintained up to 200 °C, but superplastic behavior is found above this temperature when the alloy is processed through a powder metallurgy route.

  13. Phosphonic acid based ion exchange resins

    DOEpatents

    Horwitz, E. Philip; Alexandratos, Spiro D.; Gatrone, Ralph C.; Chiarizia, Ronato

    1994-01-01

    An ion exchange resin for extracting metal ions from a liquid waste stream. An ion exchange resin is prepared by copolymerizing a vinylidene disphosphonic acid with styrene, acrylonitrile and divinylbenzene.

  14. Phosphonic acid based ion exchange resins

    DOEpatents

    Horwitz, E. Philip; Alexandratos, Spiro D.; Gatrone, Ralph C.; Chiarizia, Ronato

    1996-01-01

    An ion exchange resin for extracting metal ions from a liquid waste stream. An ion exchange resin is prepared by copolymerizing a vinylidene diphosphonic acid with styrene, acrylonitrile and divinylbenzene.

  15. 21 CFR 177.2260 - Filters, resin-bonded.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Filters, resin-bonded. 177.2260 Section 177.2260... Use § 177.2260 Filters, resin-bonded. Resin-bonded filters may be safely used in producing... filters are prepared from natural or synthetic fibers to which have been added substances required in...

  16. Method of removing contaminants from plastic resins

    DOEpatents

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2008-11-18

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  17. Method of removing contaminants from plastic resins

    DOEpatents

    Bohnert, George W [Harrisonville, MO; Hand, Thomas E [Lee's Summit, MO; Delaurentiis, Gary M [Jamestown, CA

    2007-08-07

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  18. Method for removing contaminants from plastic resin

    DOEpatents

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2008-12-30

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  19. Cure shrinkage in casting resins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spencer, J. Brock

    2015-02-01

    A method is described whereby the shrinkage of a casting resin can be determined. Values for the shrinkage of several resin systems in frequent use by Sandia have been measured. A discussion of possible methods for determining the stresses generated by cure shrinkage and thermal contraction is also included.

  20. Simultaneous uptake of NOM and Microcystin-LR by anion exchange resins: Effect of inorganic ions and resin regeneration.

    PubMed

    Dixit, Fuhar; Barbeau, Benoit; Mohseni, Madjid

    2018-02-01

    This study investigated the efficiency of a strongly basic macroporous anion exchange resin for the co-removal of Microcystin-LR (MCLR) and natural organic matter (NOM) in waters affected by toxic algal blooms. Environmental factors influencing the uptake behavior included MCLR and resin concentrations, NOM and anionic species, specifically nitrate, sulphate and bicarbonate. A860 resin exhibited an excellent adsorption capacity of 3800 μg/g; more than 60% of the MCLR removal was achieved within 10 min with a resin dosage of 200 mg/L (∼1 mL/L). Further, kinetic studies revealed that the overall removal of MCLR is influenced by both external diffusion and intra-particle diffusion. Increasing NOM concentration resulted in a significant reduction of MCLR uptake, especially at lower resin dosages, where a competitive uptake between the charged NOM fractions and MCLR was observed due to limited active sites. In addition, MCLR uptake was significantly reduced in the presence of sulphate and nitrate in the water matrix. Moreover, performance of the resin proved to be stable from one regeneration cycle to another. Approximately 80% of MCLR and 50% of dissolved organic carbon (DOC) were recovered in the regenerated brine. Evidences of resin saturation and site reduction were also observed after 2000 bed volumes (BV) of operation. For all the investigated water matrices, a resin dosage of 1000 mg/L (∼4.5 mL/L) was sufficient to lower MCLR concentration from 100 μg/L to below the World Health Organization guideline of 1 μg/L, while simultaneously providing more than 80% NOM removal. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Flavylium chromophores as species markers for dragon's blood resins from Dracaena and Daemonorops trees.

    PubMed

    Sousa, Micaela M; Melo, Maria J; Parola, A Jorge; Seixas de Melo, J Sérgio; Catarino, Fernando; Pina, Fernando; Cook, Frances E M; Simmonds, Monique S J; Lopes, João A

    2008-10-31

    A simple and rapid liquid chromatographic method with diode-array UV-vis spectrophotometric detection has been developed for the authentication of dragon's blood resins from Dracaena and Daemonorops trees. Using this method it was discovered that the flavylium chromophores, which contribute to the red colour of these resins, differ among the species and could be used as markers to differentiate among species. A study of parameters, such as time of extraction, proportion of MeOH and pH, was undertaken to optimise the extraction of the flavyliums. This method was then used to make extracts from samples of dragon's blood resin obtained from material of known provenance. From the samples analysed 7,6-dihydroxy-5-methoxyflavylium (dracorhodin), 7,4'-dihydroxy-5-methoxyflavylium (dracoflavylium) and 7,4'-dihydroxyflavylium were selected as species markers for Daemonorops spp., Dracaena draco and Dracaena cinnabari, respectively. The chromatograms from these samples were used to build an HPLC-DAD database. The ability to discriminate among species of dragon's blood using the single marker compounds was compared with a principal components analysis of the chromatograms in the HPLC-DAD database. The results from the HPLC-DAD method based on the presence of these flavylium markers was unequivocal. The HPLC-DAD method was subsequently applied to 37 samples of dragon blood resins from the historical samples in the Economic Botany Collection, Royal Botanic Gardens, Kew. The method identified anomalies in how samples in this collection had been labelled. It is clear that the method can be used to evaluate the provenance of samples used in different areas of cultural heritage. It also could be used to monitor the trade of endangered species of dragon's blood and the species being used in complex formulations of traditional Chinese medicine.

  2. Radiopacity of conventional, resin-modified glass ionomer, and resin-based luting materials.

    PubMed

    Tsuge, Takuma

    2009-06-01

    The purpose of the present study was to evaluate the radiopacity of currently available dental luting materials. Five conventional cements, six resin-modified glass ionomers (RMGIs), two methyl methacrylate (MMA)-based acrylic resins (eight shades), and nine composite luting materials were evaluated. Radiographs of the specimens were taken together with tooth slices and aluminum step wedges. The density of the specimens was determined with a densitometer and was expressed in terms of the equivalent thickness of aluminum per 2.0-mm unit thickness of specimen. The radiopacity values for human enamel and dentin were 4.3 and 2.3 mm Al/2.0 mm specimen, respectively. The values for materials ranged from 5.1 to 12.9 for conventional luting materials, from 3.4 to 6.3 for RMGIs, from less than 0.5 to 7.3 for MMA resins, and from 2.3 to 9.9 for the composite luting materials. A zinc phosphate cement showed the highest value (12.9), whereas five shades of MMA resin resulted in the lowest value (less than 0.5). Two RMGIs and three composite luting materials exhibited radiopacity values between those of enamel (4.3) and dentin (2.3). It can be concluded that the radiopacity value of luting materials varies considerably, and that care must be taken when selecting luting materials, considering the material composition of restorations.

  3. Special features of changes in the structure and mechanical properties of oxygen-free pure and yttrium-alloyed copper after vacuum induction remelting

    NASA Astrophysics Data System (ADS)

    Kamyshanchenko, N. V.; Galtsev, A. V.; Durykhin, M. I.; Neklyudov, I. M.; Borts, B. V.; Shevchenko, S. V.

    2011-03-01

    Properties of oxygen-free copper with a microadditive of yttrium and without it are studied after vacuum induction remelting. The ingots are subjected to intense hot pressing and subsequent rolling to various degrees of reduction. The effects of the annealing temperature on the structure and of the anisotropy of the structure on the strength properties of the copper are determined. The properties of copper with an additive of yttrium and without it are compared.

  4. Magneto-optical properties of cerium substituted yttrium iron garnet films with reduced thermal budget for monolithic photonic integrated circuits.

    PubMed

    Goto, Taichi; Onbaşlı, Mehmet C; Ross, C A

    2012-12-17

    Thin films of polycrystalline cerium substituted yttrium iron garnet (CeYIG) were grown on an yttrium iron garnet (YIG) seed layer on Si and Si-on-insulator substrates by pulsed laser deposition, and their optical and magneto-optical properties in the near-IR region were measured. A YIG seed layer of ~30 nm thick processed by rapid thermal anneal at 800°C provided a virtual substrate to promote crystallization of the CeYIG. The effect of the thermal budget of the YIG/CeYIG growth process on the film structure, magnetic and magnetooptical properties was determined.

  5. Improved iodine radiolabels for monoclonal antibody therapy.

    PubMed

    Stein, Rhona; Govindan, Serengulam V; Mattes, M Jules; Chen, Susan; Reed, Linda; Newsome, Guy; McBride, Bill J; Griffiths, Gary L; Hansen, Hans J; Goldenberg, David M

    2003-01-01

    by virtue of high tumor uptake and retention and low normal organ uptake, as well as superior radiochemical properties. The therapeutic efficacy of (131)I-IMP-R4-RS7 was compared with that of conventionally (131)I-labeled RS7 and (90)yttrium-RS7 in the nude mice lung cancer model. The therapeutic efficacy of (131)I-IMP-R4-RS7 and (90)yttrium-RS7 were equivalent, and both agents yielded significantly improved control of tumor growth compared with conventional (131)I-labeled RS7.

  6. Method of making a composite refractory material

    DOEpatents

    Morrow, M.S.; Holcombe, C.E.

    1995-09-26

    A composite refractory material is prepared by combining boron carbide with furan resin to form a mixture containing about 8 wt. % furan resin. The mixture is formed into a pellet which is placed into a grit pack comprising an oxide of an element such as yttrium to form a sinterable body. The sinterable body is sintered under vacuum with microwave energy at a temperature no greater than 2000 C to form a composite refractory material.

  7. Phosphonic acid based ion exchange resins

    DOEpatents

    Horwitz, E.P.; Alexandratos, S.D.; Gatrone, R.C.; Chiarizia, R.

    1996-07-23

    An ion exchange resin is described for extracting metal ions from a liquid waste stream. An ion exchange resin is prepared by copolymerizing a vinylidene diphosphonic acid with styrene, acrylonitrile and divinylbenzene. 10 figs.

  8. 21 CFR 177.1585 - Polyestercarbonate resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... solution intrinsic viscosity of the polyestercarbonate resins shall be a minimum of 0.44 deciliter per gram, as determined by a method entitled “Intrinsic Viscosity (IV) of Lexan ® Polyestercarbonate Resin by a...

  9. 21 CFR 177.1585 - Polyestercarbonate resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... solution intrinsic viscosity of the polyestercarbonate resins shall be a minimum of 0.44 deciliter per gram, as determined by a method entitled “Intrinsic Viscosity (IV) of Lexan ® Polyestercarbonate Resin by a...

  10. 21 CFR 177.1585 - Polyestercarbonate resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... intrinsic viscosity of the polyestercarbonate resins shall be a minimum of 0.44 deciliter per gram, as determined by a method entitled “Intrinsic Viscosity (IV) of Lexan ® Polyestercarbonate Resin by a Single...

  11. Phosphonic acid based ion exchange resins

    DOEpatents

    Horwitz, E.P.; Alexandratos, S.D.; Gatrone, R.C.; Chiarizia, R.

    1994-01-25

    An ion exchange resin is described for extracting metal ions from a liquid waste stream. An ion exchange resin is prepared by copolymerizing a vinylidene diphosphonic acid with styrene, acrylonitrile and divinylbenzene. 9 figures.

  12. 21 CFR 177.1585 - Polyestercarbonate resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... solution intrinsic viscosity of the polyestercarbonate resins shall be a minimum of 0.44 deciliter per gram, as determined by a method entitled “Intrinsic Viscosity (IV) of Lexan ® Polyestercarbonate Resin by a...

  13. Optimized small molecule antibody labeling efficiency through continuous flow centrifugal diafiltration.

    PubMed

    Cappione, Amedeo; Mabuchi, Masaharu; Briggs, David; Nadler, Timothy

    2015-04-01

    Protein immuno-detection encompasses a broad range of analytical methodologies, including western blotting, flow cytometry, and microscope-based applications. These assays which detect, quantify, and/or localize expression for one or more proteins in complex biological samples, are reliant upon fluorescent or enzyme-tagged target-specific antibodies. While small molecule labeling kits are available with a range of detection moieties, the workflow is hampered by a requirement for multiple dialysis-based buffer exchange steps that are both time-consuming and subject to sample loss. In a previous study, we briefly described an alternative method for small-scale protein labeling with small molecule dyes whereby all phases of the conjugation workflow could be performed in a single centrifugal diafiltration device. Here, we expand on this foundational work addressing functionality of the device at each step in the workflow (sample cleanup, labeling, unbound dye removal, and buffer exchange/concentration) and the implications for optimizing labeling efficiency. When compared to other common buffer exchange methodologies, centrifugal diafiltration offered superior performance as measured by four key parameters (process time, desalting capacity, protein recovery, retain functional integrity). Originally designed for resin-based affinity purification, the device also provides a platform for up-front antibody purification or albumin carrier removal. Most significantly, by exploiting the rapid kinetics of NHS-based labeling reactions, the process of continuous diafiltration minimizes reaction time and long exposure to excess dye, guaranteeing maximal target labeling while limiting the risks associated with over-labeling. Overall, the device offers a simplified workflow with reduced processing time and hands-on requirements, without sacrificing labeling efficiency, final yield, or conjugate performance. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Characterization of product capture resin during microbial cultivations.

    PubMed

    Frykman, Scott; Tsuruta, Hiroko; Galazzo, Jorge; Licari, Peter

    2006-06-01

    Various bioactive small molecules produced by microbial cultivation are degraded in the culture broth or may repress the formation of additional product. The inclusion of hydrophobic adsorber resin beads to capture these products in situ and remove them from the culture broth can reduce or prevent this degradation and repression. These product capture beads are often subjected to a dynamic and stressful microenvironment for a long cultivation time, affecting their physical structure and performance. Impact and collision forces can result in the fracturing of these beads into smaller pieces, which are difficult to recover at the end of a cultivation run. Various contaminating compounds may also bind in a non-specific manner to these beads, reducing the binding capacity of the resin for the product of interest (fouling). This study characterizes resin bead binding capacity (to monitor bead fouling), and resin bead volume distributions (to monitor bead fracture) for an XAD-16 adsorber resin used to capture epothilone produced during myxobacterial cultivations. Resin fouling was found to reduce the product binding capacity of the adsorber resin by 25-50%. Additionally, the degree of resin bead fracture was found to be dependent on the cultivation length and the impeller rotation rate. Microbial cultivations and harvesting processes should be designed in such a way to minimize bead fragmentation and fouling during cultivation to maximize the amount of resin and associated product harvested at the end of a run.

  15. Improved high-temperature resistant matrix resins

    NASA Technical Reports Server (NTRS)

    Green, H. E.; Chang, G. E.; Wright, W. F.; Ueda, K.; Orell, M. K.

    1989-01-01

    A study was performed with the objective of developing matrix resins that exhibit improved thermo-oxidative stability over state-of-the-art high temperature resins for use at temperatures up to 644 K (700 F) and air pressures up to 0.7 MPa (100 psia). The work was based upon a TRW discovered family of polyimides currently licensed to and marketed by Ethyl Corporation as EYMYD(R) resins. The approach investigated to provide improved thermo-oxidative properties was to use halogenated derivatives of the diamine, 2, 2-bis (4-(4-aminophenoxy)phenyl) hexafluoropropane (4-BDAF). Polyimide neat resins and Celion(R) 12,000 composites prepared from fluorine substituted 4-BDAF demonstrated unexpectedly lower glass transition temperatures (Tg) and thermo-oxidative stabilities than the baseline 4-BDAF/PMDA polymer.

  16. Effect of Energy Drinks on Discoloration of Silorane and Dimethacrylate-Based Composite Resins

    PubMed Central

    Ahmadizenouz, Ghazaleh; Esmaeili, Behnaz; Ahangari, Zohreh; Khafri, Soraya; Rahmani, Aghil

    2016-01-01

    Objectives: This study aimed to assess the effects of two energy drinks on color change (ΔE) of two methacrylate-based and a silorane-based composite resin after one week and one month. Materials and Methods: Thirty cubic samples were fabricated from Filtek P90, Filtek Z250 and Filtek Z350XT composite resins. All the specimens were stored in distilled water at 37°C for 24 hours. Baseline color values (L*a*b*) of each specimen were measured using a spectrophotometer according to the CIEL*a*b* color system. Ten randomly selected specimens from each composite were then immersed in the two energy drinks (Hype, Red Bull) and artificial saliva (control) for one week and one month. Color was re-assessed after each storage period and ΔE values were calculated. The data were analyzed using the Kruskal Wallis and Mann–Whitney U tests. Results: Filtek Z250 composite showed the highest ΔE irrespective of the solutions at both time points. After seven days and one month, the lowest ΔE values were observed in Filtek Z350XT and Filtek P90 composites immersed in artificial saliva, respectively. The ΔE values of Filtek Z250 and Z350XT composites induced by Red Bull and Hype energy drinks were not significantly different. Discoloration of Filtek P90 was higher in Red Bull energy drink at both time points. Conclusions: Prolonged immersion time in all three solutions increased ΔE values of all composites. However, the ΔE values were within the clinically acceptable range (<3.3) at both time points. PMID:28127318

  17. The combined effect of food-simulating solutions, brushing and staining on color stability of composite resins

    PubMed Central

    Silva, Tânia Mara Da; Sales, Ana Luísa Leme Simões; Pucci, Cesar Rogerio; Borges, Alessandra Bühler; Torres, Carlos Rocha Gomes

    2017-01-01

    Abstract Objective: This study evaluated the effect of food-simulating media associated with brushing and coffee staining on color stability of different composite resins. Materials and methods: Eighty specimens were prepared for each composite: Grandio SO (Voco), Amaris (Voco), Filtek Z350XT (3M/ESPE), Filtek P90 (3M/ESPE). They were divided into four groups according to food-simulating media for 7 days: artificial saliva (control), heptane, citric acid and ethanol. The composite surface was submitted to 10,950 brushing cycles (200 g load) in an automatic toothbrushing machine. The specimens were darkened with coffee solution at 37 °C for 24 h. After each treatment, color measurements were assessed by spectrophotometry, using CIE L*a*b* system. The overall color change (ΔE) was determined for each specimen at baseline (C1) and after the treatments (food-simulating media immersion/C2, brushing/C3 and dye solution/C4). Data were analyzed by two-way repeated measures ANOVA and Tukey’s tests (p < .05). Results: The results of RM-ANOVA showed significant differences for composites (p = .001), time (p = .001) and chemical degradation (p = .002). The mean of ΔE for composites were: Z350XT (5.39)a, Amaris (3.89)b, Grandio (3.75)bc, P90 (3.36)c. According to food-simulating media: heptane (4.41)a, citric acid (4.24)a, ethanol (4.02)ab, artificial saliva (3.76)b. For the treatments: dye solution (4.53)a, brushing (4.26)a, after food-simulating media (3.52)b. Conclusions: The composite resin Filtek Z350XT showed significantly higher staining than all other composite resin tested. The immersion in heptane and citric acid produced the highest color alteration than other food-simulating media. The exposure of samples to brushing protocols and darkening in coffee solution resulted in significant color alteration of the composite resins. PMID:28642926

  18. Determination of 90Sr / 238U ratio by double isotope dilution inductively coupled plasma mass spectrometer with multiple collection in spent nuclear fuel samples with in situ 90Sr / 90Zr separation in a collision-reaction cell

    NASA Astrophysics Data System (ADS)

    Isnard, H.; Aubert, M.; Blanchet, P.; Brennetot, R.; Chartier, F.; Geertsen, V.; Manuguerra, F.

    2006-02-01

    Strontium-90 is one of the most important fission products generated in nuclear industry. In the research field concerning nuclear waste disposal in deep geological environment, it is necessary to quantify accurately and precisely its concentration (or the 90Sr / 238U atomic ratio) in irradiated fuels. To obtain accurate analysis of radioactive 90Sr, mass spectrometry associated with isotope dilution is the most appropriated method. But, in nuclear fuel samples the interference with 90Zr must be previously eliminated. An inductively coupled plasma mass spectrometer with multiple collection, equipped with an hexapole collision cell, has been used to eliminate the 90Sr / 90Zr interference by addition of oxygen in the collision cell as a reactant gas. Zr + ions are converted into ZrO +, whereas Sr + ions are not reactive. A mixed solution, prepared from a solution of enriched 84Sr and a solution of enriched 235U was then used to quantify the 90Sr / 238U ratio in spent fuel sample solutions using the double isotope dilution method. This paper shows the results, the reproducibility and the uncertainties that can be obtained with this method to quantify the 90Sr / 238U atomic ratio in an UOX (uranium oxide) and a MOX (mixed oxide) spent fuel samples using the collision cell of an inductively coupled plasma mass spectrometer with multiple collection to perform the 90Sr / 90Zr separation. A comparison with the results obtained by inductively coupled plasma mass spectrometer with multiple collection after a chemical separation of strontium from zirconium using a Sr spec resin (Eichrom) has been performed. Finally, to validate the analytical procedure developed, measurements of the same samples have been performed by thermal ionization mass spectrometry, used as an independent technique, after chemical separation of Sr.

  19. 21 CFR 1271.90 - Are there exceptions from the requirement of determining donor eligibility, and what labeling...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... for reproductive use; or (3) Cryopreserved cells or tissue for reproductive use, other than embryos... recipient. (4) A cryopreserved embryo, originally exempt under paragraph (a)(2) of this section at the time... embryo to the recipient. (b) Required labeling. As applicable, you must prominently label an HCT/P...

  20. 21 CFR 1271.90 - Are there exceptions from the requirement of determining donor eligibility, and what labeling...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... for reproductive use; or (3) Cryopreserved cells or tissue for reproductive use, other than embryos... recipient. (4) A cryopreserved embryo, originally exempt under paragraph (a)(2) of this section at the time... embryo to the recipient. (b) Required labeling. As applicable, you must prominently label an HCT/P...

  1. Estrogenicity of resin-based composites and sealants used in dentistry.

    PubMed Central

    Olea, N; Pulgar, R; Pérez, P; Olea-Serrano, F; Rivas, A; Novillo-Fertrell, A; Pedraza, V; Soto, A M; Sonnenschein, C

    1996-01-01

    We tested some resin-based composites used in dentistry for their estrogenic activity. A sealant based on bisphenol-A diglycidylether methacrylate (bis-GMA) increased cell yields, progesterone receptor expression, and pS2 secretion in human estrogen-target, serum-sensitive MCF7 breast cancer cells. Estrogenicity was due to bisphenol-A and bisphenol-A dimethacrylate, monomers found in the base paste of the dental sealant and identified by mass spectrometry. Samples of saliva from 18 subjects treated with 50 mg of a bis-GMA-based sealant applied on their molars were collected 1 hr before and after treatment. Bisphenol-A (range 90-931 micrograms) was identified only in saliva collected during a 1-hr period after treatment. The use of bis-GMA-based resins in dentistry, and particularly the use of sealants in children, appears to contribute to human exposure to xenoestrogens. Images Figure 1. A Figure 1. B Figure 2. Figure 3. A Figure 3. B Figure 4. A Figure 4. B Figure 5. A Figure 5. B Figure 6. A Figure 6. B Figure 7. A Figure 7. B Figure 8. Figure 9. Figure 10. PMID:8919768

  2. Elucidation of the Hsp90 C-terminal Inhibitor Binding Site

    PubMed Central

    Matts, Robert L.; Dixit, Anshuman; Peterson, Laura B.; Sun, Liang; Voruganti, Sudhakar; Kalyanaraman, Palgunan; Hartson, Steve D.; Verkhivker, Gennady M.; Blagg, Brian S. J.

    2011-01-01

    The Hsp90 chaperone machine is required for the folding, activation and/or stabilization of more than 50 proteins directly related to malignant progression. Hsp90 contains small molecule binding sites at both its N- and C-terminal domains, however, limited structural and biochemical data regarding the C-terminal binding site is available. In this report, the small molecule binding site in the Hsp90 C-terminal domain was revealed by protease fingerprinting and photoaffinity labeling utilizing LC-MS/MS. The identified site was characterized by generation of a homology model for hHsp90α using the SAXS open structure of HtpG and docking the bioactive conformation of NB into the generated model. The resulting model for the bioactive conformation of NB bound to Hsp90α is presented herein. PMID:21548602

  3. Resin film infusion mold tooling and molding method

    NASA Technical Reports Server (NTRS)

    Burgess, Roger (Inventor); Grossheim, Brian (Inventor); Mouradian, Karbis (Inventor); Thrash, Patrick J. (Inventor)

    1999-01-01

    A mold apparatus and method for resin film infusion molding including an outer mold tool having a facing sheet adapted to support a resin film and preform assembly. The facing sheet includes attachment features extending therefrom. An inner mold tool is positioned on the facing sheet to enclose the resin film and preform assembly for resin film infusion molding. The inner mold tool includes a plurality of mandrels positioned for engagement with the resin film and preform assembly. Each mandrel includes a slot formed therein. A plurality of locating bars cooperate with the slots and with the attachment features for locating the mandrels longitudinally on the outer mold tool.

  4. Photosensitive filler minimizes internal stresses in epoxy resins

    NASA Technical Reports Server (NTRS)

    Dillon, J. N.

    1967-01-01

    Photosensitive filler is added to curable epoxy resins to minimize stress from internal shrinkage during curing or polymerization. Cinnamic acid resins and cinnamal ketones may be added in the amount of 1 to 3 percent by weight of the resin mixture.

  5. Toothbrush abrasion of paint-on resins for shade modification and crown resins: effect of water absorption.

    PubMed

    Fujii, Koichi; Arikawa, Hiroyuki; Kanie, Takahito; Ban, Seiji

    2004-06-01

    In order to investigate the clinical application of paint-on resins, the effect of water absorption on toothbrush abrasion and light transmittance of ten crown resins including three paint-on resins was examined. Water absorption into each material ranged from 0.29 to 0.89 mg/cm2 after storage in distilled-water for 6 weeks and their hardnesses decreased by 3.5-22.3%. Maximum surface roughness (Rmax) of the materials stored in distilled water for 6 weeks increased with an increasing number of toothbrush abrasion cycles and ranged from 1.9 to 10.5 microm after 100,000 cycles. Also, Maximum depth and weight loss as an indicator of the amount of each material lost by abrasion showed similar behaviors similar to Rmax. These results indicated that the abrasion resistance of paint-on resins was located in the middle among all materials examined.

  6. Spectroscopic investigation of the Cr to Tm energy transfer in Yttrium Aluminum Garnet (YAG) crystals

    NASA Technical Reports Server (NTRS)

    Dibartolo, B.

    1988-01-01

    New and interesting schemes have recently been considered for the efficient operation of solid-state ionic laser systems. Often the available data on these systems were obtained only because they seemed directly related to the laser performance and provide no insight into the physical processes. A more systematic approach is desirable, where more attention is devoted to the elementary basic processes and to the nature of the mechanisms at work. It is with this aim that we have undertaken the present study. Yttrium Aluminum Garnet (Y4Al5O12), called YAG, has two desirable properties as host for rare earth impurities: (1) trivalent rare earth ions can replace the yttrium without any charge compensation problem, and (2) YAG crystals have high cutoff energies. The results of measurements and calculations indicate that the Cr(3+) ion in YAG can be used to sensitize efficiently the Tm(3+) ion.

  7. A Continuous Procedure Based on Column Chromatography to Purify Anthocyanins from Schisandra chinensis by a Macroporous Resin plus Gel Filtration Chromatography.

    PubMed

    Yue, Daran; Yang, Lei; Liu, Shouxin; Li, Jian; Li, Wei; Ma, Chunhui

    2016-02-06

    In our previous study, as natural food colorants and antioxidants, the color and content stabilities of Schisandra chinensis (S. chinensis) anthocyanins were investigated. In this work, the purification process parameters of S. chinensis anthocyanins using a macroporous resin and gel filtration chromatography were evaluated. The optimized parameters of static adsorption and desorption were as follows. The selected resin is HPD-300 (nonpolar copolymer styrene type resin), and the anthocyanins adsorption saturation capacity of HPD-300 resin was 0.475 mg/g dry resin. Adsorption time was 4 h, and 0.517 mg/mL of S. chinensis anthocyanins was adsorbed on the resin column with a flow rate of 39 mL/h (3 BV/h). After adsorption, the anthocyanins were completely desorpted with 2.5 BV of 90% (v/v) ethanol solution, and the desorption flow rate was 13 mL/h (1 BV/h). After purification by dynamic adsorption and desorption, the anthocyanins content in the effluent increased from 47.6 mg/g to 128.4 mg/g, the purity of anthocyanins increased six-fold from 5.08% to 30.43%, and the anthocyanins recovery was 96.5%. The major constituent of S. chinensis anthocyanins was isolated with Bio-Gel P2 gel filtration chromatography, and it was detected by liquid chromatography electrospray ionisation tandem mass spectrometry (LC-ESI-MS) as cyanidin-3-O-xylosylrutinoside. Moreover, the antioxidant activities of S. chinensis anthocyanins were investigated. After purification using the HPD-300 resin, the antioxidant activities of anthocyanins were increased 1.2-fold (FRAP) and 1.7-fold (ABTS).

  8. Traumatic resin ducts as indicators of bark beetle outbreaks

    Treesearch

    R. Justin DeRose; Matthew F. Bekker; James N. Long

    2017-01-01

    The formation of traumatic resin ducts (TRDs) represents an important induced defense in woody plants that enhances oleoresin production and flow in response to environmental perturbations. In some genera (Pinus), resin ducts are copious and conspicuous; however, in others (Picea), resin ducts are relatively rare. The occurrence and strength of resin ducts, in...

  9. Yttrium oxide based three dimensional metamaterials for visible light cloaking

    NASA Astrophysics Data System (ADS)

    Rai, Pratyush; Kumar, Prashanth S.; Varadan, Vijay K.; Ruffin, Paul; Brantley, Christina; Edwards, Eugene

    2014-04-01

    Metamaterial with negative refractive index is the key phenomenon behind the concept of a cloaking device to hide an object from light in visible spectrum. Metamaterials made of two and three dimensional lattices of periodically placed electromagnetic resonant cells can achieve absorption and propagation of incident electromagnetic radiation as confined electromagnetic fields confined to a waveguide as surface plasmon polaritons, which can be used for shielding an object from in-tune electromagnetic radiation. The periodicity and dimensions of resonant cavity determine the frequency, which are very small as compared to the wavelength of incident light. Till now the phenomena have been demonstrated only for lights in near infrared spectrum. Recent advancements in fabrication techniques have made it possible to fabricate array of three dimensional nanostructures with cross-sections as small as 25 nm that are required for negative refractive index for wavelengths in visible light spectrum of 400-700 nm and for wider view angle. Two types of metamaterial designs, three dimensional concentric split ring and fishnet, are considered. Three dimensional structures consisted of metal-dielectric-metal stacks. The metal is silver and dielectric is yttrium oxide, other than conventional materials such as FR4 and Duroid. High κ dielectric and high refractive index as well as large crystal symmetry of Yttrium oxide has been investigated as encapsulating medium. Dependence of refractive index on wavelength and bandwidth of negative refractive index region are analyzed for application towards cloaking from light in visible spectrum.

  10. Bismaleimide resins for flame resistant honeycomb sandwich panels

    NASA Technical Reports Server (NTRS)

    Stenzenberger, H. D.

    1978-01-01

    Bismaleimide resins are prime candidates for nonflammable aircraft interior panels. Three resin types with different structures and processing characteristics were formulated. Resin M 751 was used to fabricate 100 kg of glass fabric prepregs which were used for the preparation of face sheets for honeycomb sandwich panels. Prepreg characteristics and curing cycles for laminate fabrication are provided. In order to advance beyond the current solvent resin technology for fibre and fabric impregnation, a hot melt solvent-less resin system was prepared and characterized. Preliminary tests were performed to develop a wet bonding process for the fabrication of advanced sandwich honeycomb panels by use of polybismaleimide glass fabric face sheets and polybismaleimide Nomex honeycomb core. B-stage material was used for both the core and the face sheet, providing flatwise tensile properties equivalent to those obtained by the state-of-the-art 3-step process which includes an epoxy adhesive resin.

  11. Characterization of PMR polyimide resin and prepreg

    NASA Technical Reports Server (NTRS)

    Lindenmeyer, P. H.; Sheppard, C. H.

    1984-01-01

    Procedures for the chemical characterization of PMR-15 resin solutions and graphite-reinforced prepregs were developed, and a chemical data base was established. In addition, a basic understanding of PMR-15 resin chemistry was gained; this was translated into effective processing procedures for the production of high quality graphite composites. During the program the PMR monomers and selected model compounds representative of postulated PMR-15 solution chemistry were acquired and characterized. Based on these data, a baseline PMR-15 resin was formulated and evaluated for processing characteristics and composite properties. Commercially available PMR-15 resins were then obtained and chemically characterized. Composite panels were fabricated and evaluated.

  12. Resin selection criteria for tough composite structures

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.; Smith, G. T.

    1983-01-01

    Resin selection criteria are derived using a structured methodology consisting of an upward integrated mechanistic theory and its inverse (top-down structured theory). These criteria are expressed in a "criteria selection space" which are used to identify resin bulk properties for improved composite "toughness". The resin selection criteria correlate with a variety of experimental data including laminate strength, elevated temperature effects and impact resistance.

  13. Polymerization shrinkage stress of composite resins and resin cements - What do we need to know?

    PubMed

    Soares, Carlos José; Faria-E-Silva, André Luis; Rodrigues, Monise de Paula; Vilela, Andomar Bruno Fernandes; Pfeifer, Carmem Silvia; Tantbirojn, Daranee; Versluis, Antheunis

    2017-08-28

    Polymerization shrinkage stress of resin-based materials have been related to several unwanted clinical consequences, such as enamel crack propagation, cusp deflection, marginal and internal gaps, and decreased bond strength. Despite the absence of strong evidence relating polymerization shrinkage to secondary caries or fracture of posterior teeth, shrinkage stress has been associated with post-operative sensitivity and marginal stain. The latter is often erroneously used as a criterion for replacement of composite restorations. Therefore, an indirect correlation can emerge between shrinkage stress and the longevity of composite restorations or resin-bonded ceramic restorations. The relationship between shrinkage and stress can be best studied in laboratory experiments and a combination of various methodologies. The objective of this review article is to discuss the concept and consequences of polymerization shrinkage and shrinkage stress of composite resins and resin cements. Literature relating to polymerization shrinkage and shrinkage stress generation, research methodologies, and contributing factors are selected and reviewed. Clinical techniques that could reduce shrinkage stress and new developments on low-shrink dental materials are also discussed.

  14. 40 CFR 721.2755 - Cycloaliphatic epoxy resin (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Cycloaliphatic epoxy resin (generic... Substances § 721.2755 Cycloaliphatic epoxy resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as cycloaliphatic epoxy resin (PMN...

  15. 40 CFR 721.2755 - Cycloaliphatic epoxy resin (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Cycloaliphatic epoxy resin (generic... Substances § 721.2755 Cycloaliphatic epoxy resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as cycloaliphatic epoxy resin (PMN...

  16. 40 CFR 721.2755 - Cycloaliphatic epoxy resin (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Cycloaliphatic epoxy resin (generic... Substances § 721.2755 Cycloaliphatic epoxy resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as cycloaliphatic epoxy resin (PMN...

  17. 40 CFR 721.2755 - Cycloaliphatic epoxy resin (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Cycloaliphatic epoxy resin (generic... Substances § 721.2755 Cycloaliphatic epoxy resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as cycloaliphatic epoxy resin (PMN...

  18. 40 CFR 721.2755 - Cycloaliphatic epoxy resin (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Cycloaliphatic epoxy resin (generic... Substances § 721.2755 Cycloaliphatic epoxy resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as cycloaliphatic epoxy resin (PMN...

  19. Synthesis and toughness properties of resins and composites

    NASA Technical Reports Server (NTRS)

    Johnston, N. J.

    1984-01-01

    Tensile and shear moduli of four ACEE (Aircraft Energy Efficiency Program) resins are presented along with ACEE composite material modulus predictions based on micromechanics. Compressive strength and fracture toughness of the resins and composites were discussed. In addition, several resin synthesis techniques are reviewed.

  20. One pot synthesis of chitosan grafted quaternized resin for the removal of nitrate and phosphate from aqueous solution.

    PubMed

    Banu, H Thagira; Meenakshi, Sankaran

    2017-11-01

    The present study deals with the synthesis of chitosan quaternized resin for efficient removal of nitrate and phosphate from aqueous solution. The resin was characterized with FTIR, SEM with EDX and XRD. Batch method was carried out to optimize various parameters such as contact time, initial concentration of nitrate and phosphate, dosage, pH, co-anions and temperature on the adsorption capacity of the adsorbent. The adsorption process illustrated that the Freundlich isotherm and the pseudo-second order are the best fitted models for the sorption of both anions. The respective negative values of ΔH° and ΔG° revealed that the adsorption of both the anions were exothermic and spontaneous. The removal efficiency of nitrate and phosphate on chitosan quaternized resin were 78% and 90% respectively with 0.1g of adsorbent and the initial concentration as 100mg/L. Nitrate and phosphate anions adsorbed effectively on chitosan quaternized resin by replacing Cl - ions from quaternary site through electrostatic attraction as well as ion-exchange mechanism. Hydrogen bonding also played important role in adsorption process. Even after 7th regeneration cycle the adsorbent retained its adsorption capacity as 23.7mg/g and 30.4mg/g for both nitrate and phosphate respectively. Copyright © 2017 Elsevier B.V. All rights reserved.