Sample records for zeta potential titration

  1. Surface electrochemical properties of red mud (bauxite residue): zeta potential and surface charge density.

    PubMed

    Liu, Yanju; Naidu, Ravendra; Ming, Hui

    2013-03-15

    The surface electrochemical properties of red mud (bauxite residue) from different alumina refineries in Australia and China were studied by electrophoresis and measuring surface charge density obtained from acid/base potentiometric titrations. The electrophoretic properties were measured from zeta potentials obtained in the presence of 0.01 and 0.001 M KNO(3) over a wide pH range (3.5-10) by titration. The isoelectric point (IEP) values were found to vary from 6.35 to 8.70 for the red mud samples. Further investigation into the surface charge density of one sample (RRM) by acid/base potentiometric titration showed similar results for pH(PZC) with pH(IEP) obtained from electrokinetic measurements. The pH(IEP) determined from zeta potential measurements can be used as a characteristic property of red mud. The minerals contained in red mud contributed to the different values of pH(IEP) of samples obtained from different refineries. Different relationships of pH(IEP) with Al/Fe and Al/Si ratios (molar basis) were also found for different red mud samples. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Cell surface groups of two picocyanobacteria strains studied by zeta potential investigations, potentiometric titration, and infrared spectroscopy.

    PubMed

    Dittrich, Maria; Sibler, Sabine

    2005-06-15

    In order to clarify the role of picocyanobacteria in aquatic biogeochemical processes (e.g., calcite precipitation), cell surface properties need to be investigated. An experimental study of the cell surface characteristics of two Synechococcus-type unicellular autotrophic picocyanobacterial strains was carried out. One strain was isolated from Lake Plon and contained phycocyanin, the other strain came from Lago Maggiore and was rich in phycoerythrin. Potentiometric titrations were conducted to determine the different types of sites present on the bacteria cell walls. Infrared spectroscopy allowed characterization of the various functional groups (RNH(2), RCOOH, ROH, RPO(2)) and investigations of zeta potential provided insight into the isoelectrical points of the strains. Titrations reveal three distinct sites on the bacterial surfaces of phycocyanin- and phycoerythrin-rich strains with pK values of 4.8+/-0.3/5.0+/-0.2, 6.6+/-0.2/6.7+/-0.4, and 8.8+/-0.1/8.7+/-0.2, corresponding to carboxyl, phosphate, and amine groups with surface densities of 2.6+/-0.4/7.4+/-1.6 x 10(-4), 1.9+/-0.5/4.4+/-0.8 x 10(-4), and 2.5+/-0.4/4.8+/-0.7 x 10(-4) mol/g of dry bacteria. The deprotonation constants are similar to those of bacterial strains and site densities are also within an order of magnitude of other strains. The phycoerythrin-rich strain had a higher number of binding sites than the phycocyanin-rich strain. The results showed that picocyanobacteria may adsorb either calcium cations or carbonate anions and therefore strongly influence the biogeochemical cycling of calcite in pelagic systems.

  3. The adsorption of cationic and amphoteric copolymers on glass surfaces: zeta potential measurements, adsorption isotherm determination, and FT Raman characterization.

    PubMed

    Tartakovsky, Alla; Drutis, Dane M; Carnali, Joseph O

    2003-07-15

    The adsorption of cationic and amphoteric copolymers onto controlled pore glass (CPG) powders has been studied by measurement of the powder particle zeta (zeta) potential, by determination of the adsorption isotherm, and by FT Raman measurements of the polymer-coated powder. The cationic polymers consisted chiefly of homopolymers of dimethyldiallylammonium chloride (DMDAAC) or copolymers of DMDAAC and acrylamide. The amphoteric polymers studied included copolymers of DMDAAC and acrylic acid. The comonomer ratio was varied to explore the dependence of cationic charge density on the extent and effect of adsorption. Both types of polymers adsorb onto the anionic glass surface via an ion-exchange mechanism. Consequently, a correspondingly higher mass of a low-charge-density copolymer adsorbs than of a cationic homopolymer. The presence of the anionic portion in the amphoteric polymers does not significantly alter this picture. The zeta potential, however, reflects the overall nature of the polymer. Cationic polymers effectively neutralize the glass surface, while amphoteric polymers leave the zeta potential net negative. Adsorption isotherms, determined via the depletion technique using colloidal titration, were used to "calibrate" a FT Raman method. The latter was used to determined the amount of adsorbed polymer under solution conditions in which colloidal titration could not be performed.

  4. Zeta potential control for electrophoresis cells

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.

    1973-01-01

    Zeta potential arises from fact that ions tend to be adsorbed on surface of cell walls. This potential interfaces with electric field sensed by migrating particles and degrades resolution of separation. By regulating sign and magnitude of applied potential induced charge can be used to increase or decrease effective wall zeta potential.

  5. Secondary electroosmotic flow in microchannels with nonuniform and asymmetric Zeta potential

    NASA Astrophysics Data System (ADS)

    Zhang, Jinbai; He, Guowei; Liu, Feng

    2004-11-01

    Microfluidics has a broad range of applications in biotechnology, such as sample injection, drug delivering, solution mixing, and separations. All of these techniques require handling fluids in the low Reynolds number (Re) regime. Electroosmotic flow (EOF) or electroosmocitcs is the bulk movement of liquid relative to a stationary surface due to an externally applied electronic field. It is an alternative to pressure-driven flows with convenient implementation The driving force for EOF is dependent on the zeta potential. Previous reseraches focus on the nonuniform Zeta potential. In the present work, we consider nonuniform and asymmetric Zeta potential. The effects of asymmetric Zeta potential on the EOF are investigated analytically and simulated numerically. It is demonstrated that the nonuniform and asymmetric Zeta potential can generate more flow patterns for microfluidic control compared to symmetric Zeta potential.

  6. Influence of surface conductivity on the apparent zeta potential of calcite.

    PubMed

    Li, Shuai; Leroy, Philippe; Heberling, Frank; Devau, Nicolas; Jougnot, Damien; Chiaberge, Christophe

    2016-04-15

    Zeta potential is a physicochemical parameter of particular importance in describing the surface electrical properties of charged porous media. However, the zeta potential of calcite is still poorly known because of the difficulty to interpret streaming potential experiments. The Helmholtz-Smoluchowski (HS) equation is widely used to estimate the apparent zeta potential from these experiments. However, this equation neglects the influence of surface conductivity on streaming potential. We present streaming potential and electrical conductivity measurements on a calcite powder in contact with an aqueous NaCl electrolyte. Our streaming potential model corrects the apparent zeta potential of calcite by accounting for the influence of surface conductivity and flow regime. We show that the HS equation seriously underestimates the zeta potential of calcite, particularly when the electrolyte is diluted (ionic strength ⩽ 0.01 M) because of calcite surface conductivity. The basic Stern model successfully predicted the corrected zeta potential by assuming that the zeta potential is located at the outer Helmholtz plane, i.e. without considering a stagnant diffuse layer at the calcite-water interface. The surface conductivity of calcite crystals was inferred from electrical conductivity measurements and computed using our basic Stern model. Surface conductivity was also successfully predicted by our surface complexation model. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Investigating the time-dependent zeta potential of wood surfaces.

    PubMed

    Muff, Livius F; Luxbacher, Thomas; Burgert, Ingo; Michen, Benjamin

    2018-05-15

    This work reports on streaming potential measurements through natural capillaries in wood and investigates the cause of a time-dependent zeta potential measured during the equilibration of wood cell-walls with an electrolyte solution. For the biomaterial, this equilibration phase takes several hours, which is much longer than for many other materials that have been characterized by electrokinetic measurements. During this equilibration phase the zeta potential magnitude is decaying due to two parallel mechanisms: (i) the swelling of the cell-wall which causes a dimensional change reducing the charge density at the capillary interface; (ii) the transport of ions from the electrolyte solution into the permeable cell-wall which alters the electrical potential at the interface by internal charge compensation. The obtained results demonstrate the importance of equilibration kinetics for an accurate determination of the zeta potential, especially for materials that interact strongly with the measurement electrolyte. Moreover, the change in zeta potential with time can be correlated with the bulk swelling of wood if the effect of electrolyte ion diffusion is excluded. This study shows the potential of streaming potential measurements of wood, and possibly of other hygroscopic and nanoporous materials, to reveal kinetic information about their interaction with liquids, such as swelling and ion uptake. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Molecular origins of the zeta potential

    DOE PAGES

    Predota, Milan; Machesky, Michael L.; Wesolowski, David J.

    2016-09-19

    The zeta potential (ZP) is an oft-reported measure of the macroscopic charge state of solid surfaces and colloidal particles in contact with solvents. However, the origin of this readily measurable parameter has remained divorced from the molecular-level processes governing the underlying electrokinetic phenomena, which limits its usefulness. Here, we connect the macroscopic measure to the microscopic realm through nonequilibrium molecular dynamics simulations of electroosmotic flow between parallel slabs of the hydroxylated (110) rutile (TiO 2) surface. These simulations provided streaming mobilities, which were converted to ZP via the commonly used Helmholtz-Smoluchowski equation. A range of rutile surface charge densities (0.1more » to –0.4 C/m 2), corresponding to pH values between about 2.8 and 9.4, in RbCl, NaCl, and SrCl 2 aqueous solutions, were modeled and compared to experimental ZPs for TiO 2 particle suspensions. Simulated ZPs qualitatively agree with experiment and show that “anomalous” ZP values and inequalities between the point of zero charge derived from electrokinetic versus pH titration measurements both arise from differing co- and counterion sorption affinities. We show that at the molecular level the ZP arises from the delicate interplay of spatially varying dynamics, structure, and electrostatics in a narrow interfacial region within about 15 Å of the surface, even in dilute salt solutions. This contrasts fundamentally with continuum descriptions of such interfaces, which predict the ZP response region to be inversely related to ionic strength. In reality the properties of this interfacial region are dominated by relatively immobile and structured water. Furthermore, viscosity values are substantially greater than in the bulk, and electrostatic potential profiles are oscillatory in nature.« less

  9. High-concentration zeta potential measurements using light-scattering techniques

    PubMed Central

    Kaszuba, Michael; Corbett, Jason; Watson, Fraser Mcneil; Jones, Andrew

    2010-01-01

    Zeta potential is the key parameter that controls electrostatic interactions in particle dispersions. Laser Doppler electrophoresis is an accepted method for the measurement of particle electrophoretic mobility and hence zeta potential of dispersions of colloidal size materials. Traditionally, samples measured by this technique have to be optically transparent. Therefore, depending upon the size and optical properties of the particles, many samples will be too concentrated and will require dilution. The ability to measure samples at or close to their neat concentration would be desirable as it would minimize any changes in the zeta potential of the sample owing to dilution. However, the ability to measure turbid samples using light-scattering techniques presents a number of challenges. This paper discusses electrophoretic mobility measurements made on turbid samples at high concentration using a novel cell with reduced path length. Results are presented on two different sample types, titanium dioxide and a polyurethane dispersion, as a function of sample concentration. For both of the sample types studied, the electrophoretic mobility results show a gradual decrease as the sample concentration increases and the possible reasons for these observations are discussed. Further, a comparison of the data against theoretical models is presented and discussed. Conclusions and recommendations are made from the zeta potential values obtained at high concentrations. PMID:20732896

  10. Interrelationship between the zeta potential and viscoelastic properties in coacervates complexes.

    PubMed

    Espinosa-Andrews, Hugo; Enríquez-Ramírez, Karina Esmeralda; García-Márquez, Eristeo; Ramírez-Santiago, Cesar; Lobato-Calleros, Consuelo; Vernon-Carter, Jaime

    2013-06-05

    The formation of the complex coacervate (CC) phases between gum Arabic (GA) and low molecular weight chitosan (Ch) and the interrelationship between the zeta-potential and viscoelastic properties of the coacervate phase were investigated. The maximum charge difference of biopolymers stock dispersion was displayed in a range of pH between 4.0 and 5.5. Titration experiment between the oppositely charged biopolymers showed that the isoelectric point was found at a biopolymers mass ratio (R[GA:Ch]) of R[5.5:1]. Turbidity, size and ζ-potential of the soluble complexes (SC) showed an interrelation with the complex coacervate yield (CCY). Higher CCY values (82.2-88.1%) were obtained in the range from R[3:1] to R[5.5:1]. Change the R[GA:Ch] in dispersion, make possible to produce CC's phases exhibiting cationic (R[1:1] and R[3:1]), neutral (R[5.5:1]) or anionic (R[9:1] and R[7:1]) charged. All CC's exhibited liquid-viscoelastic behavior at lower frequencies and a crossover between G″ and G' at higher frequencies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Oscillatory electroosmotic flow in a parallel-plate microchannel under asymmetric zeta potentials

    NASA Astrophysics Data System (ADS)

    Peralta, M.; Arcos, J.; Méndez, F.; Bautista, O.

    2017-06-01

    In this work, we conduct a theoretical analysis of the start-up of an oscillatory electroosmotic flow (EOF) in a parallel-plate microchannel under asymmetric zeta potentials. It is found that the transient evolution of the flow field is controlled by the parameters {R}ω , {R}\\zeta , and \\bar{κ }, which represent the dimensionless frequency, the ratio of the zeta potentials of the microchannel walls, and the electrokinetic parameter, which is defined as the ratio of the microchannel height to the Debye length. The analysis is performed for both low and high zeta potentials; in the former case, an analytical solution is derived, whereas in the latter, a numerical solution is obtained. These solutions provide the fundamental characteristics of the oscillatory EOFs for which, with suitable adjustment of the zeta potential and the dimensionless frequency, the velocity profiles of the fluid flow exhibit symmetric or asymmetric shapes.

  12. Zeta potential of microfluidic substrates: 1. Theory, experimental techniques, and effects on separations.

    PubMed

    Kirby, Brian J; Hasselbrink, Ernest F

    2004-01-01

    This paper summarizes theory, experimental techniques, and the reported data pertaining to the zeta potential of silica and silicon with attention to use as microfluidic substrate materials, particularly for microchip chemical separations. Dependence on cation concentration, buffer and cation type, pH, cation valency, and temperature are discussed. The Debye-Hückel limit, which is often correctly treated as a good approximation for describing the ion concentration in the double layer, can lead to serious errors if it is extended to predict the dependence of zeta potential on the counterion concentration. For indifferent univalent electrolytes (e.g., sodium and potassium), two simple scalings for the dependence of zeta potential on counterion concentration can be derived in high- and low-zeta limits of the nonlinear Poisson-Boltzman equation solution in the double layer. It is shown that for most situations relevant to microchip separations, the high-zeta limit is most applicable, leading to the conclusion that the zeta potential on silica substrates is approximately proportional to the logarithm of the molar counterion concentration. The zeta vs. pH dependence measurements from several experiments are compared by normalizing the zeta based on concentration.

  13. An induced current method for measuring zeta potential of electrolyte solution-air interface.

    PubMed

    Song, Yongxin; Zhao, Kai; Wang, Junsheng; Wu, Xudong; Pan, Xinxiang; Sun, Yeqing; Li, Dongqing

    2014-02-15

    This paper reports a novel and very simple method for measuring the zeta potential of electrolyte solution-air interface. When a measuring electrode contacts the electrolyte solution-air interface, an electrical current will be generated due to the potential difference between the electrode-air surface and the electrolyte solution-air interface. The amplitude of the measured electric signal is linearly proportional to this potential difference; and depends only on the zeta potential at the electrolyte solution-air interface, regardless of the types and concentrations of the electrolyte. A correlation between the zeta potential and the measured voltage signal is obtained based on the experimental data. Using this equation, the zeta potential of any electrolyte solution-air interface can be evaluated quickly and easily by inserting an electrode through the electrolyte solution-air interface and measuring the electrical signal amplitude. This method was verified by comparing the obtained results of NaCl, MgCl2 and CaCl2 solutions of different pH values and concentrations with the zeta potential data reported in the published journal papers. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Zeta-potential Analyses using Micro Electrical Field Flow Fractionation with Fluorescent Nanoparticles

    PubMed Central

    Chang, Moon-Hwan; Dosev, Dosi; Kennedy, Ian M.

    2007-01-01

    Increasingly growing application of nanoparticles in biotechnology requires fast and accessible tools for their manipulation and for characterization of their colloidal properties. In this work we determine the zeta-potentials for polystyrene nanoparticles using micro electrical field flow fractionation (μ–EFFF) which is an efficient method for sorting of particles by size. The data obtained by μ–EFFF were compared to zeta potentials determined by standard capillary electrophoresis. For proof of concept, we used polystyrene nanoparticles of two different sizes, impregnated with two different fluorescent dyes. Fluorescent emission spectra were used to evaluate the particle separation in both systems. Using the theory of electrophoresis, we estimated the zeta-potentials as a function of size, dielectric permittivity, viscosity and electrophoretic mobility. The results obtained by the μ–EFFF technique were confirmed by the conventional capillary electrophoresis measurements. These results demonstrate the applicability of the μ–EFFF method not only for particle size separation but also as a simple and inexpensive tool for measurements of nanoparticles zeta potentials. PMID:18542710

  15. Application of the zeta potential for stationary phase characterization in ion chromatography.

    PubMed

    Buszewski, Bogusław; Jaćkowska, Magdalena; Bocian, Szymon; Dziubakiewicz, Ewelina

    2013-01-01

    Two series of homemade stationary bonded phases for ion chromatography were investigated according to their zeta potential. One set of dendrimer anion exchanger was synthesized on the polymer support whereas the second material was prepared on the silica gel. The zeta potential data in water environment as well as buffered water solution were obtained. The influence of the length of anion-exchanger chains, the type of the support of the modified surface, and charge distribution on these data was investigated. Additionally, the zeta potential was correlated with retention factor of inorganic ions to describe their influence on the retention mechanism in ion chromatography. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Synthesis, bioactivity and zeta potential investigations of chlorine and fluorine substituted hydroxyapatite.

    PubMed

    Fahami, Abbas; Beall, Gary W; Betancourt, Tania

    2016-02-01

    Chlorine and fluorine substituted hydroxyapatites (HA-Cl-F) with different degrees of ion replacement were successfully prepared by the one step mechanochemical activation method. X-ray diffraction (XRD) and FT-IR spectra indicated that substitution of these anions in milled powders resulted in the formation of pure hydroxyapatite phase except for the small observed change in the lattice parameters and unit cell volumes of the resultant hydroxyapatite. Microscopic observations showed that the milled product had a cluster-like structure made up of polygonal and spherical particles with an average particle size of approximately ranged from 20±5 to 70±5nm. The zeta potential of milled samples was performed at three different pH (5, 7.4, and 9). The obtained zeta potential values were negative for all three pH values. Negative zeta potential was described to favor osseointegration, apatite nucleation, and bone regeneration. The bioactivity of samples was investigated on sintered pellets soaked in simulated body fluid (SBF) solution and apatite crystals formed on the surface of the pellets after being incubated for 14days. Zeta potential analysis and bioactivity experiment suggested that HA-Cl-F will lead to the formation of new apatite particles and therefore be a potential implant material. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Surface Complexation Modeling of Calcite Zeta Potential Measurement in Mixed Brines for Carbonate Wettability Characterization

    NASA Astrophysics Data System (ADS)

    Song, J.; Zeng, Y.; Biswal, S. L.; Hirasaki, G. J.

    2017-12-01

    We presents zeta potential measurements and surface complexation modeling (SCM) of synthetic calcite in various conditions. The systematic zeta potential measurement and the proposed SCM provide insight into the role of four potential determining cations (Mg2+, SO42- , Ca2+ and CO32-) and CO2 partial pressure in calcite surface charge formation and facilitate the revealing of calcite wettability alteration induced by brines with designed ionic composition ("smart water"). Brines with varying potential determining ions (PDI) concentration in two different CO2 partial pressure (PCO2) are investigated in experiments. Then, a double layer SCM is developed to model the zeta potential measurements. Moreover, we propose a definition for contribution of charged surface species and quantitatively analyze the variation of charged species contribution when changing brine composition. After showing our model can accurately predict calcite zeta potential in brines containing mixed PDIs, we apply it to predict zeta potential in ultra-low and pressurized CO2 environments for potential applications in carbonate enhanced oil recovery including miscible CO2 flooding and CO2 sequestration in carbonate reservoirs. Model prediction reveals that pure calcite surface will be positively charged in all investigated brines in pressurized CO2 environment (>1atm). Moreover, the sensitivity of calcite zeta potential to CO2 partial pressure in the various brine is found to be in the sequence of Na2CO3 > Na2SO4 > NaCl > MgCl2 > CaCl2 (Ionic strength=0.1M).

  18. Zeta Potential Measurements on Solid Surfaces for in Vitro Biomaterials Testing: Surface Charge, Reactivity Upon Contact With Fluids and Protein Absorption

    PubMed Central

    Ferraris, Sara; Cazzola, Martina; Peretti, Veronica; Stella, Barbara; Spriano, Silvia

    2018-01-01

    Surface properties of biomaterials (e.g., roughness, chemical composition, charge, wettability, and hydroxylation degree) are key features to understand and control the complex interface phenomena that happens upon contact with physiological fluids. Numerous physico-chemical techniques can be used in order to investigate in depth these crucial material features. Among them, zeta potential measurements are widely used for the characterization of colloidal suspensions, but actually poorly explored in the study of solid surfaces, even if they can give significant information about surface charge in function of pH and indirectly about surface functional groups and reactivity. The aim of the present research is application of zeta potential measurements of solid surfaces for the in vitro testing of biomaterials. In particular, bare and surface modified Ti6Al4V samples have been compared in order to evaluate their isoelectric points (IEPs), surface charge at physiological pH, in vitro bioactivity [in simulated body fluid (SBF)] and protein absorption. Zeta potential titration was demonstrated as a suitable technique for the surface characterization of surface treated Ti6Al4V substrates. Significant shift of the isoelectric point was recorded after a chemical surface treatment (because of the exposition of hydroxyl groups), SBF soaking (because of apatite precipitation IEP moves close to apatite one) and protein absorption (IEP moves close to protein ones). Moreover, the shape of the curve gives information about exposed functional groups (e.g., a plateau in the basic range appears due to the exposition of acidic OH groups and in the acidic range due to exposition of basic NH2 groups). PMID:29868575

  19. Measurement of Zeta-Potential at Microchannel Wall by a Nanoscale Laser Induced Fluorescence Imaging

    NASA Astrophysics Data System (ADS)

    Kazoe, Yutaka; Sato, Yohei

    A nanoscale laser induced fluorescence imaging was proposed by using fluorescent dye and the evanescent wave with total internal reflection of a laser beam. The present study focused on the two-dimensional measurement of zeta-potential at the microchannel wall, which is an electrostatic potential at the wall surface and a dominant parameter of electroosmotic flow. The evanescent wave, which decays exponentially from the wall, was used as an excitation light of the fluorescent dye. The fluorescent intensity detected by a CCD camera is closely related to the zeta-potential. Two kinds of fluorescent dye solution at different ionic concentrations were injected into a T-shaped microchannel, and formed a mixing flow field in the junction area. The two-dimensional distribution of zeta-potential at the microchannel wall in the pressure-driven flow field was measured. The obtained zeta-potential distribution has a transverse gradient toward the mixing flow field and was changed by the difference in the averaged velocity of pressure-driven flow. To understand the ion motion in the mixing flow field, the three-dimensional flow structure was analyzed by the velocity measurement using micron-resolution particle image velocimetry and the numerical simulation. It is concluded that the two-dimensional distribution of zeta-potential at the microchannel wall was dependent on the ion motion in the flow field, which was governed by the convection and molecular diffusion.

  20. A Comparison of Streaming and Microelectrophoresis Methods for Obtaining the zeta Potential of Granular Porous Media Surfaces.

    PubMed

    Johnson

    1999-01-01

    The electrokinetic behavior of granular quartz sand in aqueous solution is investigated by both microelectrophoresis and streaming potential methods. zeta potentials of surfaces composed of granular quartz obtained via streaming potential methods are compared to electrophoretic mobility zeta potential values of colloid-sized quartz fragments. The zeta values generated by these alternate methods are in close agreement over a wide pH range and electrolyte concentrations spanning several orders of magnitude. Streaming measurements performed on chemically heterogeneous mixtures of physically homogeneous sand are shown to obey a simple mixing model based on the surface area-weighted average of the streaming potentials associated with the individual end members. These experimental results support the applicability of the streaming potential method as a means of determining the zeta potential of granular porous media surfaces. Copyright 1999 Academic Press.

  1. Cursory examination of the zeta potential behaviors of two optical materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tesar, A.; Oja, T.

    1992-01-02

    When an oxide surface is placed in water, a difference in potential across the interface occurs due to dipole orientation. Hydroxyl groups or bound oxygen atoms on the oxide surface will orient adjacent water molecules which balance the dipole charge. This occurs over some small distance called the electrical double layer. Trace amounts of high field strength ions present in the vicinity of the double layer can have significant effects on the double layer. When there is movement of the oxide surface with respect to the water, a shearing of the double layer occurs. The electrical potential at this surfacemore » of shear is termed the zeta potential. The impetus for this study was to document the zeta potential behavior in water of two optical materials. (1) a multicomponent phosphate glass; and (2) Zerodur, a silicate glass-ceramic.« less

  2. Zeta potential in ceramic industry

    NASA Technical Reports Server (NTRS)

    Lecuit, M.

    1984-01-01

    Deflocculation, electrical conductivity and zeta potential (ZP) are studied for the addition of 0 to 10000 ppm Na2SiO3 deflocculator to slips obtained from three argillaceous materials (kaolin d'Arvor, ball clay Hyplas 64, and/or Granger Clay No. 10). The quantity of Na2SO3 required to deflocculate a slip is independent of the density but differes for each clay. The ZP is directly related to the density of the slip. The higher the ZP the more stable a slip is; the value of the ZP of a mixture does not follow a simple law but the electrical resistance of a mixture does follow a simple additive law. The ZP appears to have linear relation with the specific surface of the argillaceous material.

  3. Estimation of zeta potential of electroosmotic flow in a microchannel using a reduced-order model.

    PubMed

    Park, H M; Hong, S M; Lee, J S

    2007-10-01

    A reduced-order model is derived for electroosmotic flow in a microchannel of nonuniform cross section using the Karhunen-Loève Galerkin (KLG) procedure. The resulting reduced-order model is shown to predict electroosmotic flows accurately with minimal consumption of computer time for a wide range of zeta potential zeta and dielectric constant epsilon. Using the reduced-order model, a practical method is devised to estimate zeta from the velocity measurements of the electroosmotic flow in the microchannel. The proposed method is found to estimate zeta with reasonable accuracy even with noisy velocity measurements.

  4. Zeta potential orientation dependence of sapphire substrates.

    PubMed

    Kershner, Ryan J; Bullard, Joseph W; Cima, Michael J

    2004-05-11

    The zeta potential of planar sapphire substrates for three different crystallographic orientations was measured by a streaming potential technique in the presence of KCl and (CH3)4NCl electrolytes. The streaming potential was measured for large single crystalline C-plane (0001), A-plane (1120), and R-plane (1102) wafers over a full pH range at three or more ionic strengths ranging from 1 to 100 mM. The roughness of the epi-polished wafers was verified using atomic force microscopy to be on the order of atomic scale, and X-ray photoelectron spectroscopy (XPS) was used to ensure that the samples were free of silica and other contaminants. The results reveal a shift in the isoelectric point (iep) of the three samples by as much as two pH units, with the R-plane surface exhibiting the most acidic behavior and the C-plane samples having the highest iep. The iep at all ionic strengths was tightly centered around a single pH for each wafer. These values of iep are substantially different from the range of pH 8-10 consistently reported in the literature for alpha-Al2O3 particles. Particle zeta potential measurements were performed on a model powder using phase analysis light scattering, and the iep was confirmed to occur at pH 8. Modified Auger parameters (MAP) were calculated from XPS spectra of a monolayer of iridium metal deposited on the sapphire by electron beam deposition. A shift in MAP consistent with the observed differences in iep of the surfaces confirms the effect of surface structure on the transfer of charge between the Ir and sapphire, hence accounting for the changes in acidity as a function of crystallographic orientation.

  5. Electrokinetically driven active micro-mixers utilizing zeta potential variation induced by field effect

    NASA Astrophysics Data System (ADS)

    Lee, Chia-Yen; Lee, Gwo-Bin; Fu, Lung-Ming; Lee, Kuo-Hoong; Yang, Ruey-Jen

    2004-10-01

    This paper presents a new electrokinetically driven active micro-mixer which uses localized capacitance effects to induce zeta potential variations along the surface of silica-based microchannels. The mixer is fabricated by etching bulk flow and shielding electrode channels into glass substrates and then depositing Au/Cr thin films within the latter to form capacitor electrodes, which establish localized zeta potential variations near the electrical double layer (EDL) region of the electroosmotic flow (EOF) within the microchannels. The potential variations induce flow velocity changes within a homogeneous fluid and a rapid mixing effect if an alternating electric field is provided. The current experimental data confirm that the fluid velocity can be actively controlled by using the capacitance effect of the buried shielding electrodes to vary the zeta potential along the channel walls. While compared with commonly used planar electrodes across the microchannels, the buried shielding electrodes prevent current leakage caused by bad bonding and allow direct optical observation during operation. It also shows that the buried shielding electrodes can significantly induce the field effect, resulting in higher variations of zeta potential. Computational fluid dynamic simulations are also used to study the fluid characteristics of the developed active mixers. The numerical and experimental results demonstrate that the developed microfluidic device permits a high degree of control over the fluid flow and an efficient mixing effect. Moreover, the developed device could be used as a pumping device as well. The development of the active electrokinetically driven micro-mixer could be crucial for micro-total-analysis-systems.

  6. Coagulation-flocculation mechanisms in wastewater treatment plants through zeta potential measurements.

    PubMed

    López-Maldonado, E A; Oropeza-Guzman, M T; Jurado-Baizaval, J L; Ochoa-Terán, A

    2014-08-30

    Based on the polyelectrolyte-contaminant physical and chemical interactions at the molecular level, this article analyzed and discussed the coagulation-flocculation and chemical precipitation processes in order to improve their efficiency. Bench experiments indicate that water pH, polyelectrolyte (PE) dosing strategy and cationic polyelectrolyte addition are key parameters for the stability of metal-PE complexes. The coagulation-flocculation mechanism is proposed based on zeta potential (ζ) measurement as the criteria to define the electrostatic interaction between pollutants and coagulant-flocculant agents. Polyelectrolyte and wastewater dispersions are exposed to an electrophoretic effect to determine ζ. Finally, zeta potential values are compared at pH 9, suggesting the optimum coagulant dose at 162mg/L polydadmac and 67mg/L of flocculant, since a complete removal of TSS and turbidity is achieved. Based on the concentration of heavy metals (0.931mg/L Sn, 0.7mg/L Fe and 0.63mg/L Pb), treated water met the Mexican maximum permissible limits. In addition, the treated water has 45mg O2/L chemical oxygen demand (COD) and 45mg C/L total organic carbon (TOC). The coagulation-flocculation mechanism is proposed taking into account both: zeta potential (ζ)-pH measurement and chemical affinity, as the criteria to define the electrostatic and chemical interaction between pollutants and polyelectrolytes. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Zeta potential in oil-brine-sandstone system and its role in oil recovery during controlled salinity waterflooding

    NASA Astrophysics Data System (ADS)

    Li, S.; Jackson, M.

    2017-12-01

    Wettability alteration is widely recognised as a primary role in improved oil recovery (IOR) during controlled salinity waterflooding (CSW) by modifying brine composition. The change of wettability of core sample depends on adsorption of polar oil compounds into the mineral surface which influences its surface charge density and zeta potential. It has been proved that zeta potentials can be useful to quantify the wettability and incremental oil recovery in natural carbonates. However, the study of zeta potential in oil-brine-sandstone system has not investigated yet. In this experimental study, the zeta potential is used to examine the controlled salinity effects on IOR in nature sandstone (Doddington) aged with two types of crude oils (Oil T and Oil D) over 4 weeks at 80 °C. Results show that the zeta potential measured in the Oil T-brine-sandstone system following primary waterflooding decreases compared to that in fully water saturation, which is consistent with the negative oil found in carbonates study, and IOR response during secondary waterflooding using diluted seawater was observed. In the case of negative oil, the injected low salinity brine induces a more repulsive electrostatic force between the mineral-brine interface and oil-brine interface, which results in an increase disjoining pressure and alters the rock surface to be more water-wet. For Oil D with a positive oil-brine interface, the zeta potential becomes more positive compared to that under single phase condition. The conventional waterflooding fails to observe the IOR in Oil D-brine-sandstone system due to a less repulsive electrostatic force built up between the two interfaces. After switching the injection brine from low salinity brine to formation brine, the IOR was observed. Measured zeta potentials shed some light on the mechanism of wettability alteration in the oil-brine-sandstone system and oil recovery during CSW.

  8. Chitosan-magnesium aluminum silicate composite dispersions: characterization of rheology, flocculate size and zeta potential.

    PubMed

    Khunawattanakul, Wanwisa; Puttipipatkhachorn, Satit; Rades, Thomas; Pongjanyakul, Thaned

    2008-03-03

    Composite dispersions of chitosan (CS), a positively charged polymer, and magnesium aluminum silicate (MAS), a negatively charged clay, were prepared and rheology, flocculate size and zeta potential of the CS-MAS dispersions were investigated. High and low molecular weights of CS (HCS and LCS, respectively) were used in this study. Moreover, the effects of heat treatment at 60 degrees C on the characteristics of the CS-MAS dispersions and the zeta potential of MAS upon addition of CS at different pHs were examined. Incorporation of MAS into CS dispersions caused an increase in viscosity and a shift of CS flow type from Newtonian to pseudoplastic flow with thixotropic properties. Heat treatment brought about a significant decrease in viscosity and hysteresis area of the composite dispersions. Microscopic studies showed that flocculation of MAS occurred after mixing with CS. The size and polydispersity index of the HCS-MAS flocculate were greater than those of the LCS-MAS flocculate. However, a narrower size distribution and the smaller size of the HCS-MAS flocculate were found after heating at 60 degrees C. Zeta potentials of the CS-MAS flocculates were positive and slightly increased with increasing MAS content. In the zeta potential studies, the negative charge of the MAS could be neutralized by the addition of CS. Increasing the pH and molecular weight of CS resulted in higher CS concentrations required to neutralize the charge of MAS. These findings suggest that the electrostatic interaction between CS and MAS caused a change in flow behavior and flocculation of the composite dispersions, depending on the molecular weight of CS. Heat treatment affected the rheological properties and the flocculate size of the composite dispersions. Moreover, pH of medium and molecular weight of CS influence the zeta potential of MAS.

  9. Influence of the Dukhin and Reynolds numbers on the apparent zeta potential of granular porous media.

    PubMed

    Crespy, A; Bolève, A; Revil, A

    2007-01-01

    The Helmholtz-Smoluchowski (HS) equation is widely used to determine the apparent zeta potential of porous materials using the streaming potential method. We present a model able to correct this apparent zeta potential of granular media of the influence of the Dukhin and Reynolds numbers. The Dukhin number represents the ratio between the surface conductivity (mainly occurring in the Stern layer) and the pore water conductivity. The Reynolds number represents the ratio between inertial and viscous forces in the Navier-Stokes equation. We show here that the HS equation can lead to serious errors if it is used to predict the dependence of zeta potential on flow in the inertial laminar flow regime without taking into account these corrections. For indifferent 1:1 electrolytes (such as sodium chloride), we derived two simple scaling laws for the dependence of the streaming potential coupling coefficient (or the apparent zeta potential) on the Dukhin and Reynolds numbers. Our model is compared with a new set of experimental data obtained on glass bead packs saturated with NaCl solutions at different salinities and pH. We find fairly good agreement between the model and these experimental data.

  10. The zeta potential of extended dielectrics and conductors in terms of streaming potential and streaming current measurements.

    PubMed

    Gallardo-Moreno, Amparo M; Vadillo-Rodríguez, Virginia; Perera-Núñez, Julia; Bruque, José M; González-Martín, M Luisa

    2012-07-21

    The electrical characterization of surfaces in terms of the zeta potential (ζ), i.e., the electric potential contributing to the interaction potential energy, is of major importance in a wide variety of industrial, environmental and biomedical applications in which the integration of any material with the surrounding media is initially mediated by the physico-chemical properties of its outer surface layer. Among the different existing electrokinetic techniques for obtaining ζ, streaming potential (V(str)) and streaming current (I(str)) are important when dealing with flat-extended samples. Mostly dielectric materials have been subjected to this type of analysis and only a few papers can be found in the literature regarding the electrokinetic characterization of conducting materials. Nevertheless, a standardized procedure is typically followed to calculate ζ from the measured data and, importantly, it is shown in this paper that such a procedure leads to incorrect zeta potential values when conductors are investigated. In any case, assessment of a reliable numerical value of ζ requires careful consideration of the origin of the input data and the characteristics of the experimental setup. In particular, it is shown that the cell resistance (R) typically obtained through a.c. signals (R(a.c.)), and needed for the calculations of ζ, always underestimates the zeta potential values obtained from streaming potential measurements. The consideration of R(EK), derived from the V(str)/I(str) ratio, leads to reliable values of ζ when dielectrics are investigated. For metals, the contribution of conductivity of the sample to the cell resistance provokes an underestimation of R(EK), which leads to unrealistic values of ζ. For the electrical characterization of conducting samples I(str) measurements constitute a better choice. In general, the findings gathered in this manuscript establish a measurement protocol for obtaining reliable zeta potentials of dielectrics and

  11. Estimation of the zeta potential and the dielectric constant using velocity measurements in the electroosmotic flows.

    PubMed

    Park, H M; Hong, S M

    2006-12-15

    In this paper we develop a method for the determination of the zeta potential zeta and the dielectric constant epsilon by exploiting velocity measurements of the electroosmotic flow in microchannels. The inverse problem is solved through the minimization of a performance function utilizing the conjugate gradient method. The present method is found to estimate zeta and epsilon with reasonable accuracy even with noisy velocity measurements.

  12. Stimulation and inhibition of enzymatic hydrolysis by organosolv lignins as determined by zeta potential and hydrophobicity.

    PubMed

    Huang, Yang; Sun, Shaolong; Huang, Chen; Yong, Qiang; Elder, Thomas; Tu, Maobing

    2017-01-01

    Lignin typically inhibits enzymatic hydrolysis of cellulosic biomass, but certain organosolv lignins or lignosulfonates enhance enzymatic hydrolysis. The hydrophobic and electrostatic interactions between lignin and cellulases play critical roles in the enzymatic hydrolysis process. However, how to incorporate these two interactions into the consideration of lignin effects has not been investigated. We examined the physicochemical properties and the structures of ethanol organosolv lignins (EOL) from hardwood and softwood and ascertained the association between lignin properties and their inhibitory and stimulatory effects on enzymatic hydrolysis. The zeta potential and hydrophobicity of EOL lignin samples, isolated from organosolv pretreatment of cottonwood (CW), black willow (BW), aspen (AS), eucalyptus (EH), and loblolly pine (LP), were determined and correlated with their effects on enzymatic hydrolysis of Avicel. EOLs from CW, BW, and AS improved the 72 h hydrolysis yield by 8-12%, while EOLs from EH and LP decreased the 72 h hydrolysis yield by 6 and 16%, respectively. The results showed a strong correlation between the 72 h hydrolysis yield with hydrophobicity and zeta potential. The correlation indicated that the hydrophobicity of EOL had a negative effect and the negative zeta potential of EOL had a positive effect. HSQC NMR spectra showed that β- O -4 linkages in lignin react with ethanol to form an α -ethoxylated β- O -4' substructure (A') during organosolv pretreatment. Considerable amounts of C 2,6 -H 2,6 correlation in p -hydroxybenzoate (PB) units were observed for EOL-CW, EOL-BW, and EOL-AS, but not for EOL-EH and EOL-LP. This study revealed that the effect of lignin on enzymatic hydrolysis is a function of both hydrophobic interactions and electrostatic repulsions. The lignin inhibition is controlled by lignin hydrophobicity and the lignin stimulation is governed by the negative zeta potential. The net effect of lignin depends on the combined

  13. Effect of additive on Zeta potential and particle size of nickel nanoparticles

    NASA Astrophysics Data System (ADS)

    Sharma, Vikash; Tarachand, Chotia, Chandrabhan; Okram, G. S.

    2017-05-01

    Nickel nanoparticles (NPs) were prepared by thermal decomposition method using Oleylamine (OLY) as a solvent and Trioctylphosphine (TOP) as a surfactant. We have investigated the effect of pH and addition of Ethylenediamine tetraacetic acid (EDTA) on the stability and particle size of Ni NPs using zeta potential and particle size analyser. Coating of the surfactants on the surface of Ni NPs was confirmed by Fourier transform infrared (FTIR) spectroscopy. Autotitration study of zeta potential of these NPs in ethanol by dynamic light scattering (DLS) at different pH values confirmed an isoelectric point (IEP) at pH = 3.64 in ethanol and pH = 3.04 after addition of EDTA in ethanol. It was observed that addition of EDTA in nanosuspension enhances stability of Ni-NPs significantly.

  14. Red blood cell membrane viscoelasticity, agglutination and zeta potential measurements with double optical tweezers

    NASA Astrophysics Data System (ADS)

    Fontes, Adriana; Fernandes, Heloise P.; Barjas-Castro, Maria L.; de Thomaz, André A.; de Ysasa Pozzo, Liliana; Barbosa, Luiz C.; Cesar, Carlos L.

    2006-02-01

    The red blood cell (RBC) viscoelastic membrane contains proteins and glycolproteins embedded in, or attached, to a fluid lipid bilayer and are negatively charged, which creates a repulsive electric (zeta) potential between the cells and prevents their aggregation in the blood stream. There are techniques, however, to decrease the zeta potential to allow cell agglutination which are the basis of most of the tests of antigen-antibody interactions in blood banks. This report shows the use of a double optical tweezers to measure RBC membrane viscosity, agglutination and zeta potential. In our technique one of the optical tweezers trap a silica bead that binds strongly to a RBC at the end of a RBCs rouleaux and, at the same time, acts as a pico-Newton force transducer, after calibration through its displacement from the equilibrium position. The other optical tweezers trap the RBC at the other end. To measure the membrane viscosity the optical force is measured as a function of the velocity between the RBCs. To measure the adhesion the tweezers are slowly displaced apart until the RBCs disagglutination happens. The RBC zeta potential is measured in two complimentary ways, by the force on the silica bead attached to a single RBC in response to an applied electric field, and the conventional way, by the measurement of terminal velocity of the RBC after released from the optical trap. These two measurements provide information about the RBC charges and, also, electrolytic solution properties. We believe this can improve the methods of diagnosis in blood banks.

  15. Electrokinetic mixing at high zeta potentials: ionic size effects on cross stream diffusion.

    PubMed

    Ahmadian Yazdi, Alireza; Sadeghi, Arman; Saidi, Mohammad Hassan

    2015-03-15

    The electrokinetic phenomena at high zeta potentials may show several unique features which are not normally observed. One of these features is the ionic size (steric) effect associated with the solutions of high ionic concentration. In the present work, attention is given to the influences of finite ionic size on the cross stream diffusion process in an electrokinetically actuated Y-shaped micromixer. The method consists of a finite difference based numerical approach for non-uniform grid which is applied to the dimensionless form of the governing equations, including the modified Poisson-Boltzmann equation. The results reveal that, neglecting the ionic size at high zeta potentials gives rise to the overestimation of the mixing length, because the steric effects retard liquid flow, thereby enhancing the mixing efficiency. The importance of steric effects is found to be more intense for channels of smaller width to height ratio. It is also observed that, in sharp contrast to the conditions that the ions are treated as point charges, increasing the zeta potential improves the cross stream diffusion when incorporating the ionic size. Moreover, increasing the EDL thickness decreases the mixing length, whereas the opposite is true for the channel aspect ratio. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Hydrodynamic dispersion in a combined magnetohydrodynamic- electroosmotic-driven flow through a microchannel with slowly varying wall zeta potentials

    NASA Astrophysics Data System (ADS)

    Vargas, C.; Arcos, J.; Bautista, O.; Méndez, F.

    2017-09-01

    The effective dispersion coefficient of a neutral solute in the combined electroosmotic (EO) and magnetohydrodynamic (MHD)-driven flow of a Newtonian fluid through a parallel flat plate microchannel is studied. The walls of the microchannel are assumed to have modulated and low zeta potentials that vary slowly in the axial direction in a sinusoidal manner. The flow field required to obtain the dispersion coefficient is solved using the lubrication approximation theory. The solution of the electrical potential is based on the Debye-Hückel approximation for a symmetric (Z :Z ) electrolyte solution. The EO and MHD effects, together with the variations in the zeta potentials of the walls, are observed to notably modify the axial distribution of the effective dispersion coefficient. The problem is formulated for two cases of the zeta potential function. Note that the dispersion coefficient primarily depends on the Hartmann number, on the ratio of the half height of the microchannel to the Debye length, and on the assumed variation in the zeta potentials of the walls.

  17. Binding of phosphoinositide-specific phospholipase C-zeta (PLC-zeta) to phospholipid membranes: potential role of an unstructured cluster of basic residues.

    PubMed

    Nomikos, Michail; Mulgrew-Nesbitt, Anna; Pallavi, Payal; Mihalyne, Gyongyi; Zaitseva, Irina; Swann, Karl; Lai, F Anthony; Murray, Diana; McLaughlin, Stuart

    2007-06-01

    Phospholipase C-zeta (PLC-zeta) is a sperm-specific enzyme that initiates the Ca2+ oscillations in mammalian eggs that activate embryo development. It shares considerable sequence homology with PLC-delta1, but lacks the PH domain that anchors PLC-delta1 to phosphatidylinositol 4,5-bisphosphate, PIP2. Thus it is unclear how PLC-zeta interacts with membranes. The linker region between the X and Y catalytic domains of PLC-zeta, however, contains a cluster of basic residues not present in PLC-delta1. Application of electrostatic theory to a homology model of PLC-zeta suggests this basic cluster could interact with acidic lipids. We measured the binding of catalytically competent mouse PLC-zeta to phospholipid vesicles: for 2:1 phosphatidylcholine/phosphatidylserine (PC/PS) vesicles, the molar partition coefficient, K, is too weak to be of physiological significance. Incorporating 1% PIP2 into the 2:1 PC/PS vesicles increases K about 10-fold, to 5x10(3) M-1, a biologically relevant value. Expressed fragments corresponding to the PLC-zeta X-Y linker region also bind with higher affinity to polyvalent than monovalent phosphoinositides on nitrocellulose filters. A peptide corresponding to the basic cluster (charge=+7) within the linker region, PLC-zeta-(374-385), binds to PC/PS vesicles with higher affinity than PLC-zeta, but its binding is less sensitive to incorporating PIP2. The acidic residues flanking this basic cluster in PLC-zeta may account for both these phenomena. FRET experiments suggest the basic cluster could not only anchor the protein to the membrane, but also enhance the local concentration of PIP2 adjacent to the catalytic domain.

  18. Effective flocculation of Chlorella vulgaris using chitosan with zeta potential measurement

    NASA Astrophysics Data System (ADS)

    Low, Y. J.; Lau, S. W.

    2017-06-01

    Microalgae are considered as one promising source of third-generation biofuels due to their fast growth rates, potentially higher yield rates and wide ranges of growth conditions. However, the extremely low biomass concentration in microalgae cultures presents a great challenge to the harvesting of microalgae because a large volume of water needs to be removed to obtain dry microalgal cells for the subsequent oil extraction process. In this study, the fresh water microalgae Chlorella vulgaris (C. vulgaris) was effectively harvested using both low molecular weight (MW) and high MW chitosan flocculants. The flocculation efficiency was evaluated by physical appearance, supernatant absorbance, zeta potential and solids content after centrifugal dewatering. High flocculation efficiency of 98.0-99.0% was achieved at the optimal dosage of 30-40 mg/g with formation of large microalgae flocs. This study suggests that the polymer bridging mechanism was governing the flocculation behaviour of C. vulgaris using high MW chitosan. Besides, charge patch neutralisation mechanism prevailed at low MW chitosan where lower dosage was sufficient to reach near-zero zeta potential compared with the high MW chitosan. The amount of chitosan polymer present in the culture may also affect the mechanism of flocculation.

  19. Zeta potentials of the rare earth element fluorcarbonate minerals focusing on bastnäsite and parisite.

    PubMed

    Owens, C L; Nash, G R; Hadler, K; Fitzpatrick, R S; Anderson, C G; Wall, F

    2018-06-01

    Rare earth elements (REE) are critical to a wide range of technologies ranging from mobile phones to wind turbines. Processing and extraction of REE minerals from ore bodies is, however, both challenging and relatively poorly understood, as the majority of deposits contain only limited enrichment of REEs. An improved understanding of the surface properties of the minerals is important in informing and optimising their processing, in particular for separation by froth flotation. The measurement of zeta potential can be used to extract information regarding the electrical double layer, and hence surface properties of these minerals. There are over 34 REE fluorcarbonate minerals currently identified, however bastnäsite, synchysite and parisite are of most economic importance. Bastnäsite-(Ce), the most common REE fluorcarbonate, supplies over 50% of the world's REE. Previous studies of bastnäsite have showed a wide range of surface behaviour, with the iso-electric point (IEP), being measured between pH values of 4.6 and 9.3. In contrast, no values of IEP have been reported for parisite or synchysite. In this work, we review previous studies of the zeta potentials of bastnäsite to investigate the effects of different methodologies and sample preparation. In addition, measurements of zeta potentials of parisite under water, collector and supernatant conditions were conducted, the first to be reported. These results showed an iso-electric point for parisite of 5.6 under water, with a shift to a more negative zeta potential with both collector (hydroxamic and fatty acids) and supernatant conditions. The IEP with collectors and supernatant was <3.5. As zeta potential measurements in the presence of reagents and supernatants are the most rigorous way of determining the efficiency of a flotation reagent, the agreement between parisite zeta potentials obtained here and previous work on bastnäsite suggests that parisite may be processed using similar reagent schemes to

  20. Entrapment of ovalbumin into liposomes--factors affecting entrapment efficiency, liposome size, and zeta potential.

    PubMed

    Brgles, Marija; Jurasin, Darija; Sikirić, Maja Dutour; Frkanec, Ruza; Tomasić, Jelka

    2008-01-01

    Various amounts of Ovalbumin (OVA) were encapsulated into positively and negatively charged multilamellar liposomes, with the aim to investigate the entrapment efficiency in different buffers and to study their effects on the liposome size and zeta potential. Results showed that the entrapment efficiency of OVA in anionic liposomes was the same in 10 mM Phosphate Buffer (PB) as in Phosphate-Buffered Saline (PBS; PB + 0.15 M NaCl). Also, liposome size was approximately 1200 nm for all anionic liposomes incorporating OVA. The entrapment efficiency of OVA in cationic liposomes was highly dependent on ionic strength. The size of cationic liposomes was approximately 1200 nm in PBS, regardless of protein content, but increased with the amount of the incorporated protein in PB. Aggregation of cationic liposomes in PB was observed when the mass of the protein was 2.5 mg or greater. The zeta potential of anionic liposomes was negative and of cationic liposomes positive in the whole range of protein mass tested. These results show how different compositions of lipid and aqueous phases can be used to vary the entrapment efficiency, liposome size, and zeta potential--the factors that are of great importance for the use of liposomes as drug carriers.

  1. Electroosmotic flow of Phan-Thien-Tanner fluids at high zeta potentials: An exact analytical solution

    NASA Astrophysics Data System (ADS)

    Sarma, Rajkumar; Deka, Nabajit; Sarma, Kuldeep; Mondal, Pranab Kumar

    2018-06-01

    We present a mathematical model to study the electroosmotic flow of a viscoelastic fluid in a parallel plate microchannel with a high zeta potential, taking hydrodynamic slippage at the walls into account in the underlying analysis. We use the simplified Phan-Thien-Tanner (s-PTT) constitutive relationships to describe the rheological behavior of the viscoelastic fluid, while Navier's slip law is employed to model the interfacial hydrodynamic slip. Here, we derive analytical solutions for the potential distribution, flow velocity, and volumetric flow rate based on the complete Poisson-Boltzmann equation (without considering the frequently used Debye-Hückel linear approximation). For the underlying electrokinetic transport, this investigation primarily reveals the influence of fluid rheology, wall zeta potential as modulated by the interfacial electrochemistry and interfacial slip on the velocity distribution, volumetric flow rate, and fluid stress, as well as the apparent viscosity. We show that combined with the viscoelasticity of the fluid, a higher wall zeta potential and slip coefficient lead to a phenomenal enhancement in the volumetric flow rate. We believe that this analysis, besides providing a deep theoretical insight to interpret the transport process, will also serve as a fundamental design tool for microfluidic devices/systems under electrokinetic influence.

  2. Study of a binary interpenetrated polymeric complex by correlation of rheological parameters with zeta potential and conductivity.

    PubMed

    Nita, Loredana Elena; Chiriac, Aurica P; Neamtu, Iordana; Bercea, Maria

    2010-03-01

    The interpenetrated macromolecular chains complexation between poly(aspartic acid) and poly(vinyl alcohol) in aqueous solution it was investigated. The interpolymer complexation process was evaluated through dynamic rheology. The aspects concerning the stability of the tested homopolymers and the prepared interpolymeric complex there were achieved from the evaluation of the aqueous solutions'zeta potential and also by determining the pH influence upon the zeta potential and the conductivity. The data obtained through the rheological dynamic measurements were correlated with the composition of the polymeric mixture, the dependence of zeta potential and conductivity. The study reveals the conditions for the formation of interpenetrated polymeric complex as being a ratio of 70wt.% PAS to 30wt.% PVA at 22 degrees C and 50/50 PAS/PVA ratio at 37 degrees C temperature. From the pH influence upon the zeta potential values it was evidenced the PAS aqueous solution does not reach the isoelectric point. At the same time, PVA solution and the complex PAS/PVA reaches the isoelectric point at strongly acid pH. The better stability of PAS, PVA and their mixture in solution is recorded in the alkaline domain (7.5or=12). The conductivity increases with the rising of the PAS content, pH and temperature. Other characteristics of the prepared interpenetrated polymeric structure, as for example thermal stability, there are also presented.

  3. EFFECT OF AQUEOUS PHASE PROPERTIES ON CLAY PARTICLE ZETA POTENTIAL AND ELECTRO-OSMOTIC PERMEABILITY: IMPLICATIONS FOR ELECTRO-KINETIC SOIL REMEDIATION PROCESSES

    EPA Science Inventory

    The influence of aqueous phase properties (pH, ionic strength and divalent metal ion concentration) on clay particle zeta potential and packed-bed electro-osmotic permeability was quantified. Although pH strongly altered the zeta potential of a Georgia kaolinite, it did not signi...

  4. Investigation of the influence of the zeta-potential on the filtration rate in the presence of collectors

    NASA Technical Reports Server (NTRS)

    Provirnina, E. V.; Barbin, M. B.

    1984-01-01

    The value of the zeta-potential does not have an explicit effect, which is expressed by a simple math correlation, on filtration rate when a solution of the tested collector is filtered through a cake prepared under standard conditions from the examined particulate material. The zeta-potential measurements and filtration tests were carried out on silica and galena with solutions contg. a cationic container ANP and Et xanthane, resp. at PH = 6.5, varying concentration of the agent (0-2500 g/ton), and under a vacuum of 100 to 600 mm Hg.

  5. Effect of the adsorption of lithium and borate species on the zeta potential of particles of cobalt ferrite, nickel ferrite, and magnetite.

    PubMed

    Barale, M; Lefèvre, G; Carrette, F; Catalette, H; Fédoroff, M; Cote, G

    2008-12-01

    Zetametric measurements on suspensions of oxide particles (cobalt ferrite, nickel ferrite, and magnetite) representative of corrosion products from primary circuits of pressurized water reactors were performed at 25 and 70 degrees C in the presence of lithium and borate species. No effect of lithium ions was observed. Borate species cause a decrease of the isoelectric point (IEP), attributed to the sorption of borate as a negative complex MOB(OH)3(-). A predictive model based on thermodynamic calculations (2-pK and diffuse layer models) of the surface acidity constants from the data of acid-base titrations combined with an empirical relationship between the surface potential Psi 0 and the zeta potential determined by zetametry was developed. A whole set of parameters valid at 25 degrees C, in a range of ionic strength between 10(-4) and 10(-2) molL(-1) and in a range of pH between 4 and 8, was determined for this model. Increase of temperature to 70 degrees C in the presence of borate results in a decrease of IEP for cobalt ferrite and an increase of the IEP for nickel ferrite.

  6. Development of a novel in silico model of zeta potential for metal oxide nanoparticles: a nano-QSPR approach

    NASA Astrophysics Data System (ADS)

    Wyrzykowska, Ewelina; Mikolajczyk, Alicja; Sikorska, Celina; Puzyn, Tomasz

    2016-11-01

    Once released into the aquatic environment, nanoparticles (NPs) are expected to interact (e.g. dissolve, agglomerate/aggregate, settle), with important consequences for NP fate and toxicity. A clear understanding of how internal and environmental factors influence the NP toxicity and fate in the environment is still in its infancy. In this study, a quantitative structure-property relationship (QSPR) approach was employed to systematically explore factors that affect surface charge (zeta potential) under environmentally realistic conditions. The nano-QSPR model developed with multiple linear regression (MLR) was characterized by high robustness ({{{Q}}{{2}}}{{CV}}=0.90) and external predictivity ({{{Q}}{{2}}}{{EXT}}=0.93). The results clearly showed that zeta potential values varied markedly as functions of the ionic radius of the metal atom in the metal oxides, confirming that agglomeration and the extent of release of free MexOy largely depend on their intrinsic properties. A developed nano-QSPR model was successfully applied to predict zeta potential in an ionized solution of NPs for which experimentally determined values of response have been unavailable. Hence, the application of our model is possible when the values of zeta potential in the ionized solution for metal oxide nanoparticles are undetermined, without the necessity of performing more time consuming and expensive experiments. We believe that our studies will be helpful in predicting the conditions under which MexOy is likely to become problematic for the environment and human health.

  7. Directional flow induced by synchronized longitudinal and zeta-potential controlling AC-electrical fields.

    PubMed

    van der Wouden, E J; Hermes, D C; Gardeniers, J G E; van den Berg, A

    2006-10-01

    Electroosmotic flow (EOF) in a microchannel can be controlled by electronic control of the surface charge using an electrode embedded in the wall of the channel. By setting a voltage to the electrode, the zeta-potential at the wall can be changed locally. Thus, the electrode acts as a "gate" for liquid flow, in analogy with a gate in a field-effect transistor. In this paper we will show three aspects of a Field Effect Flow Control (FEFC) structure. We demonstrate the induction of directional flow by the synchronized switching of the gate potential with the channel axial potential. The advantage of this procedure is that potential gas formation by electrolysis at the electrodes that provide the axial electric field is suppressed at sufficiently large switching frequencies, while the direction and magnitude of the EOF can be maintained. Furthermore we will give an analysis of the time constants involved in the charging of the insulator, and thus the switching of the zeta potential, in order to predict the maximum operating frequency. For this purpose an equivalent electrical circuit is presented and analyzed. It is shown that in order to accurately describe the charging dynamics and pH dependency the traditionally used three capacitor model should be expanded with an element describing the buffer capacitance of the silica wall surface.

  8. Optimal aluminum/zirconium: Protein interactions for predicting antiperspirant efficacy using zeta potential measurements.

    PubMed

    Yuan, Shaotang; Vaughn, John; Pappas, Iraklis; Fitzgerald, Michael; Masters, James G; Pan, Long

    2015-01-01

    The interactions between commercial antiperspirant (AP) salts [aluminum chlorohydrate (ACH), activated ACH, aluminum sesquichlorohydrate (ASCH), zirconium aluminum glycine (ZAG), activated ZAG), pure aluminum polyoxocations (Al13-mer, Al30-mer), and the zirconium(IV)-glycine complex Zr6 (O)4 (OH)4 (H2O)8 (Gly)8]12+(-) (CP-2 or ZG) with Bovine serum albumin (BSA) were studied using zeta potential and turbidity measurements. The maximal turbidity, which revealed the optimal interactions between protein and metal salts, for all protein-metal salt samples was observed at the isoelectric point (IEP), where the zeta potential of the solution was zero. Efficacy of AP salts was determined via three parameters: the amount of salt required to flocculate BSA to reach IEP, the turbidity of solution at the IEP, and the pH range over which the turbidity of the solution remains sufficiently high. By comparing active salt performance from this work to traditional prescreening methods, this methodology was able to provide a consistent efficacy assessment for metal actives in APs or in water treatment.

  9. Stability of fenbendazole suspensions for veterinary use. Correlation between zeta potential and sedimentation.

    PubMed

    Arias, José L; López-Viota, Margarita; Clares, Beatriz; Ruiz, Ma Adolfina

    2008-08-07

    In this paper we have carried out a detailed investigation of the stability and redispersibility characteristics of fenbendazole aqueous suspensions, through a thermodynamic and electrokinetic characterization, considering the effect of both pH and ionic strength. The hydrophobic character of the drug, and the surface charge and electrical double-layer thickness play an essential role in the stability of the system, hence the need for a full characterization of fenbendazole. It was found that the drug suspensions displays "delayed" or "hindered" sedimentation, determined by their hydrophobic character and their low zeta potential (indicating a small electrokinetic charge on the particles). The electrostatic repulsion between the particles is responsible for the low sedimentation volume and poor redispersibility of the drug. However, only low concentrations of AlCl(3) induced a significant effect on both the zeta potential and stability of the drug, leading to a "free-layered" sedimentation and a very easy redispersion which could be of great interest in the design of an oral pharmaceutical dosage form for veterinary.

  10. zeta 1 and zeta 2 Reticuli and the existence of the zeta Herculis group

    NASA Astrophysics Data System (ADS)

    del Peloso, E. F.; da Silva, L.; Porto de Mello, G. F.

    2000-06-01

    We report the detailed analysis of the solar type stars zeta 1 and zeta 2 Reticuli. We obtained accurate effective temperatures (T_eff = 5746 +/- 27 K and 5859 +/- 27 K respectively) and surface gravities (log g = 4.54 +/- 0.02 and 4.46 +/- 0.01 respectively). Both stars are slightly metal deficient ([Fe/H] = -0.22 +/- 0.05) and their element abundance patterns are compatible with one another and with the Sun. The hypothesis, suggested by previous detailed analyses, that these stars could be helium rich relative to the Sun, was investigated. The stars were found to have a normal, solar helium abundance. We analysed the stars' membership of the zeta Herculis stellar kinematic group (SKG). Some probable members have nearly the same galactic orbital parameters, chemical composition and evolutionary states, which confirm the existence of a metal deficient SKG. Since we determined that zeta Herculis does not belong to this group, we propose it be renamed zeta Reticuli SKG. Based on observations collected at the European Southern Observatory, La Silla, Chile, and at the Observatório do Pico dos Dias, operated by the Laboratório Nacional de Astrofísica, CNPq, Brazil.

  11. Nanoparticle Tracking Analysis for Determination of Hydrodynamic Diameter, Concentration, and Zeta-Potential of Polyplex Nanoparticles.

    PubMed

    Wilson, David R; Green, Jordan J

    2017-01-01

    Nanoparticle tracking analysis (NTA) is a recently developed nanoparticle characterization technique that offers certain advantages over dynamic light scattering for characterizing polyplex nanoparticles in particular. Dynamic light scattering results in intensity-weighted average measurements of nanoparticle characteristics. In contrast, NTA directly tracks individual particles, enabling concentration measurements as well as the direct determination of number-weighted particle size and zeta-potential. A direct number-weighted assessment of nanoparticle characteristics is particularly useful for polydisperse samples of particles, including many varieties of gene delivery particles that can be prone to aggregation. Here, we describe the synthesis of poly(beta-amino ester)/deoxyribonucleic acid (PBAE/DNA) polyplex nanoparticles and their characterization using NTA to determine hydrodynamic diameter, zeta-potential, and concentration. Additionally, we detail methods of labeling nucleic acids with fluorophores to assess only those polyplex nanoparticles containing plasmids via NTA. Polymeric gene delivery of exogenous plasmid DNA has great potential for treating a wide variety of diseases by inducing cells to express a gene of interest.

  12. Effects of image charges, interfacial charge discreteness, and surface roughness on the zeta potential of spherical electric double layers.

    PubMed

    Gan, Zecheng; Xing, Xiangjun; Xu, Zhenli

    2012-07-21

    We investigate the effects of image charges, interfacial charge discreteness, and surface roughness on spherical electric double layer structures in electrolyte solutions with divalent counterions in the setting of the primitive model. By using Monte Carlo simulations and the image charge method, the zeta potential profile and the integrated charge distribution function are computed for varying surface charge strengths and salt concentrations. Systematic comparisons were carried out between three distinct models for interfacial charges: (1) SURF1 with uniform surface charges, (2) SURF2 with discrete point charges on the interface, and (3) SURF3 with discrete interfacial charges and finite excluded volume. By comparing the integrated charge distribution function and the zeta potential profile, we argue that the potential at the distance of one ion diameter from the macroion surface is a suitable location to define the zeta potential. In SURF2 model, we find that image charge effects strongly enhance charge inversion for monovalent interfacial charges, and strongly suppress charge inversion for multivalent interfacial charges. For SURF3, the image charge effect becomes much smaller. Finally, with image charges in action, we find that excluded volumes (in SURF3) suppress charge inversion for monovalent interfacial charges and enhance charge inversion for multivalent interfacial charges. Overall, our results demonstrate that all these aspects, i.e., image charges, interfacial charge discreteness, their excluding volumes, have significant impacts on zeta potentials of electric double layers.

  13. Investigating the clinical potential for 14-3-3 zeta protein to serve as a biomarker for epithelial ovarian cancer

    PubMed Central

    2013-01-01

    Objective Recently, 14-3-3 zeta protein was identified as a potential serum biomarker of epithelial ovarian cancer (EOC). The goal of this study was to investigate the clinical potential of 14-3-3 zeta protein for monitoring EOC progression compared with CA-125 and HE4. Design Prospective follow-up study. Setting University of Pecs Medical Center Department of Obstetrics and Gynecology/Oncology (Pecs, Hungary). Population Thirteen EOC patients with advanced stage (FIGO IIb-IIIc) epithelial ovarian cancer that underwent radical surgery and received six consecutive cycles of first line chemotherapy (paclitaxel, carboplatin) in 21-day intervals. Methods Pre- and post-chemotherapy computed tomography (CT) scans were performed. Serum levels of CA-125, HE4, and 14-3-3 zeta protein were detected by enzyme-linked immunosorbent assay (ELISA) and quantitative electrochemiluminescence assay (ECLIA). Main outcome measures Serum levels of CA-125, HE4, and 14-3-3 zeta protein, as well as lesion size according to pre- and post-chemotherapy CT scans. Results Serum levels of CA-125 and HE4 were found to significantly decrease following chemotherapy, and this was consistent with the decrease in lesion size detected post-chemotherapy. In contrast, 14-3-3 zeta protein levels did not significantly differ in healthy postmenopausal patients versus EOC patients. Conclusions Determination of CA-125 and HE4 serum levels for the determination of the risk of ovarian malignancy algorithm (ROMA) represents a useful tool for the prediction of chemotherapy efficacy for EOC patients. However, levels of 14-3-3 zeta protein were not found to vary significantly as a consequence of treatment. Therefore we question if 14-3-3 zeta protein is a reliable biomarker, which correlates with the clinical behavior of EOC. PMID:24238270

  14. Zeta potential study of Sb2S3 nanoparticles synthesized by a facile polyol method in various surfactants

    NASA Astrophysics Data System (ADS)

    Saxena, Monika; Okram, Gunadhor Singh

    2018-05-01

    In the present work, we report the successful synthesis of stibnite Sb2S3 nanoparticles (NPs) by a facile polyol method using various surfactant. The structural and optical properties were investigated by X-ray diffraction (XRD), Raman spectroscopy and Zeta potential. Rietveld refinement of XRD data confirms the single phase orthorhombic crystal structure of stibnite Sb2S3. Presence of six obvious Raman modes further confirmed their stoichiometric formation. Effect of different surfactants on the surface charge of Sb2S3 NPs was studied using Zeta potential measurement in deionized water at different pH values. They reveal that these NPs are more stable when it was synthesized in presence of EDTA than that of CTAB or without surfactant samples with high zeta potential. The isoelectronic point was found at pH = 6.4 for pure sample, 3.5 and 7.2 for CTAB and not found for EDTA Sb2S3 samples. This information can be useful for many industrial applications like pharmaceuticals, ceramics, waste water treatment and medicines.

  15. Zeta-potential and particle size studies of silver sulphide nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Vikash, E-mail: vikash@csr.res.in; Tarachand,; Ganesan, V.

    Silver sulfide (Ag{sub 2}S) nanoparticles (NPs) were prepared successfully for the first time using diethylene glycol (DEG) as a surfactant. X-ray diffraction (XRD) data revealed single phase nature of the compound and energy-dispersive X-ray (EDX) confirmed its nominal composition. Their sizes were 43 nm from XRD, 50 nm from atomic force microscopy (AFM) and 19 nm & 213 nm from dynamic light scattering (DLS); their differences have been discussed. Autotitration study of zeta potential of these NPs in deionized water by DLS at different pH values confirmed an isoelectric point at pH = 5.14 and their very unstable nature in deionized water.

  16. Zeta potential in oil-water-carbonate systems and its impact on oil recovery during controlled salinity water-flooding

    PubMed Central

    Jackson, Matthew D.; Al-Mahrouqi, Dawoud; Vinogradov, Jan

    2016-01-01

    Laboratory experiments and field trials have shown that oil recovery from carbonate reservoirs can be increased by modifying the brine composition injected during recovery in a process termed controlled salinity water-flooding (CSW). However, CSW remains poorly understood and there is no method to predict the optimum CSW composition. This work demonstrates for the first time that improved oil recovery (IOR) during CSW is strongly correlated to changes in zeta potential at both the mineral-water and oil-water interfaces. We report experiments in which IOR during CSW occurs only when the change in brine composition induces a repulsive electrostatic force between the oil-brine and mineral-brine interfaces. The polarity of the zeta potential at both interfaces must be determined when designing the optimum CSW composition. A new experimental method is presented that allows this. Results also show for the first time that the zeta potential at the oil-water interface may be positive at conditions relevant to carbonate reservoirs. A key challenge for any model of CSW is to explain why IOR is not always observed. Here we suggest that failures using the conventional (dilution) approach to CSW may have been caused by a positively charged oil-water interface that had not been identified. PMID:27876833

  17. Dynamic Light Scattering and Zeta Potential of Colloidal Mixtures of Amelogenin and Hydroxyapatite in Calcium and Phosphate Rich Ionic Milieus

    PubMed Central

    Uskoković, Vuk; Odsinada, Roselyn; Djordjevic, Sonia; Habelitz, Stefan

    2011-01-01

    The concept of zeta-potential has been used for more than a century as a basic parameter in controlling the stability of colloidal suspensions, irrespective of the nature of their particulate ingredients – organic or inorganic. There are prospects that self-assembly of peptide species and the protein-mineral interactions related to biomineralization may be controlled using this fundamental physicochemical parameter. In this study, we have analyzed the particle size and zeta-potential of the full-length recombinant human amelogenin (rH174), the main protein of the developing enamel matrix, in the presence of calcium and phosphate ions and hydroxyapatite (HAP) particles. As calcium and phosphate salts are introduced to rH174 sols in increments, zeta-potential of the rH174 nanospheres is more affected by negatively charged ions, suggesting their tendency to locate within the double charge layer. Phosphate ions have a more pronounced effect on both the zeta-potential and aggregation propensity of rH174 nanospheres compared to calcium ions. The isoelectric point of amelogenin was independent on the ionic strength of the solution and the concentration of calcium and/or phosphate ions. Whereas rH174 shows a higher affinity for phosphate than for calcium, HAP attracts both of these ions to the shear plane of the double layer. The parallel size and zeta-potential analysis of HAP and rH174 colloidal mixtures indicated that at pH 7.4, despite both HAP and rH174 particles being negatively charged, rH174 adsorbs well onto HAP particles. The process is slower at pH 7.4 than at pH 4.5 when the HAP surface is negatively charged and the rH174 nanosphere carries an overall positive charge. The results presented hereby demonstrate that electrostatic interactions can affect the kinetics of the adsorption of rH174 onto HAP. PMID:21146151

  18. Influence of temperature, anions and size distribution on the zeta potential of DMPC, DPPC and DMPE lipid vesicles.

    PubMed

    Morini, M A; Sierra, M B; Pedroni, V I; Alarcon, L M; Appignanesi, G A; Disalvo, E A

    2015-07-01

    The purpose of the work is to compare the influence of the multilamellarity, phase state, lipid head groups and ionic media on the origin of the surface potential of lipid membranes. With this aim, we present a new analysis of the zeta potential of multilamellar and unilamellar vesicles composed by phosphatidylcholines (PC) and phosphatidylethanolamines (PE) dispersed in water and ionic solutions of polarizable anions, at temperatures below and above the phase transition. In general, the adsorption of anions seems to explain the origin of the zeta potential in vesicles only above the transition temperature (Tc). In this case, the sign of the surface potential is ascribed to a partial orientation of head group moiety toward the aqueous phase. This is noticeable in PC head groups but not in PEs, due to the strong lateral interaction between PO and NH group in PE. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Interlaboratory comparison for the measurement of particle size and zeta potential of silica nanoparticles in an aqueous suspension

    NASA Astrophysics Data System (ADS)

    Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.

    2011-12-01

    The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for

  20. Reduced Zeta potential through use of cationic adhesion promoter for improved resist process performance and minimizing material consumption

    NASA Astrophysics Data System (ADS)

    Hodgson, Lorna; Thompson, Andrew

    2012-03-01

    This paper presents the results of a non-HMDS (non-silane) adhesion promoter that was used to reduce the zeta potential for very thin (proprietary) polymer on silicon. By reducing the zeta potential, as measured by the minimum sample required to fully coat a wafer, the amount of polymer required to coat silicon substrates was significantly reduced in the manufacture of X-ray windows used for high transmission of low-energy X-rays. Moreover, this approach used aqueous based adhesion promoter described as a cationic surface active agent that has been shown to improve adhesion of photoresists (positive, negative, epoxy [SU8], e-beam and dry film). As well as reducing the amount of polymer required to coat substrates, this aqueous adhesion promoter is nonhazardous, and contains non-volatile solvents.

  1. Protein adsorption on dopamine-melanin films: role of electrostatic interactions inferred from zeta-potential measurements versus chemisorption.

    PubMed

    Bernsmann, Falk; Frisch, Benoît; Ringwald, Christian; Ball, Vincent

    2010-04-01

    We recently showed the possibility to build dopamine-melanin films of controlled thickness by successive immersions of a substrate in alkaline solutions of dopamine [F. Bernsmann, A. Ponche, C. Ringwald, J. Hemmerlé, J. Raya, B. Bechinger, J.-C. Voegel, P. Schaaf, V. Ball, J. Phys. Chem. C 113 (2009) 8234-8242]. In this work the structure and properties of such films are further explored. The zeta-potential of dopamine-melanin films is measured as a function of the total immersion time to build the film. It appears that the film bears a constant zeta-potential of (-39+/-3) mV after 12 immersion steps. These data are used to calculate the surface density of charged groups of the dopamine-melanin films at pH 8.5 that are mostly catechol or quinone imine chemical groups. Furthermore the zeta-potential is used to explain the adsorption of three model proteins (lysozyme, myoglobin, alpha-lactalbumin), which is monitored by quartz crystal microbalance. We come to the conclusion that protein adsorption on dopamine-melanin is not only determined by possible covalent binding between amino groups of the proteins and catechol groups of dopamine-melanin but that electrostatic interactions contribute to protein binding. Part of the adsorbed proteins can be desorbed by sodium dodecylsulfate solutions at the critical micellar concentration. The fraction of weakly bound proteins decreases with their isoelectric point. Additionally the number of available sites for covalent binding of amino groups on melanin grains is quantified. Copyright 2009 Elsevier Inc. All rights reserved.

  2. Retention of membrane charge attributes by cryopreserved-thawed sperm and zeta selection.

    PubMed

    Kam, Tricia L; Jacobson, John D; Patton, William C; Corselli, Johannah U; Chan, Philip J

    2007-09-01

    Mature sperm can be selected based on their negative zeta electrokinetic potential. The zeta selection of cryopreserved sperm is unknown. The objective was to study the effect of zeta processing on the morphology and kinematic parameters of cryopreserved-thawed sperm. Colloid-washed sperm (N = 9 cases) were cryopreserved for 24 h, thawed and diluted in serum-free medium in positive-charged tubes. After centrifugation, the tubes were decanted, serum-supplemented medium was added and the resuspended sperm were analyzed. Untreated sperm and fresh sperm served as the controls. There were improvements in strict normal morphology in fresh (11.8 +/- 0.3 versus control 8.8 +/- 0.3 %, mean +/- SEM) and thawed (8.7 +/- 0.2 versus control 5.4 +/- 0.2%) sperm after zeta processing. Percent sperm necrosis was reduced after zeta processing (66.0 +/- 0.6 versus unprocessed 74.6 +/- 0.3%). Progression decreased by 50% but not total motility after zeta processing of thawed sperm. The results suggested that the cryopreservation process did not impact the sperm membrane net zeta potential and higher percentages of sperm with normal strict morphology, acrosome integrity and reduced necrosis were recovered. The zeta method was simple and improved the selection of quality sperm after cryopreservation but more studies would be needed before routine clinical application.

  3. Flotation of algae for water reuse and biomass production: role of zeta potential and surfactant to separate algal particles.

    PubMed

    Kwak, Dong-Heui; Kim, Mi-Sug

    2015-01-01

    The effect of chemical coagulation and biological auto-flocculation relative to zeta potential was examined to compare flotation and sedimentation separation processes for algae harvesting. Experiments revealed that microalgae separation is related to auto-flocculation of Anabaena spp. and requires chemical coagulation for the whole period of microalgae cultivation. In addition, microalgae separation characteristics which are associated with surfactants demonstrated optimal microalgae cultivation time and separation efficiency of dissolved CO2 flotation (DCF) as an alternative to dissolved air flotation (DAF). Microalgae were significantly separated in response to anionic surfactant rather than cationic surfactant as a function of bubble size and zeta potential. DAF and DCF both showed slightly efficient flotation; however, application of anionic surfactant was required when using DCF.

  4. The role of zeta potential in the adhesion of E. coli to suspended intertidal sediments.

    PubMed

    Wyness, Adam J; Paterson, David M; Defew, Emma C; Stutter, Marc I; Avery, Lisa M

    2018-05-29

    The extent of pathogen transport to and within aquatic systems depends heavily on whether the bacterial cells are freely suspended or in association with suspended particles. The surface charge of both bacterial cells and suspended particles affects cell-particle adhesion and subsequent transport and exposure pathways through settling and resuspension cycles. This study investigated the adhesion of Faecal Indicator Organisms (FIOs) to natural suspended intertidal sediments over the salinity gradient encountered at the transition zone from freshwater to marine environments. Phenotypic characteristics of three E. coli strains, and the zeta potential (surface charge) of the E. coli strains and 3 physically different types of intertidal sediments was measured over a salinity gradient from 0 to 5 Practical Salinity Units (PSU). A batch adhesion microcosm experiment was constructed with each combination of E. coli strain, intertidal sediment and 0, 2, 3.5 and 5 PSU. The zeta potential profile of one E. coli strain had a low negative charge and did not change in response to an increase in salinity, and the remaining E. coli strains and the sediments exhibited a more negative charge that decreased with an increase in salinity. Strain type was the most important factor in explaining cell-particle adhesion, however adhesion was also dependant on sediment type and salinity (2, 3.5 PSU > 0, 5 PSU). Contrary to traditional colloidal (Derjaguin, Landau, Vervey, and Overbeek (DLVO)) theory, zeta potential of strain or sediment did not correlate with cell-particle adhesion. E. coli strain characteristics were the defining factor in cell-particle adhesion, implying that diverse strain-specific transport and exposure pathways may exist. Further research applying these findings on a catchment scale is necessary to elucidate these pathways in order to improve accuracy of FIO fate and transport models. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. A zeta potential value determines the aggregate's size of penta-substituted [60]fullerene derivatives in aqueous suspension whereas positive charge is required for toxicity against bacterial cells.

    PubMed

    Deryabin, Dmitry G; Efremova, Ludmila V; Vasilchenko, Alexey S; Saidakova, Evgeniya V; Sizova, Elena A; Troshin, Pavel A; Zhilenkov, Alexander V; Khakina, Ekaterina A; Khakina, Ekaterina E

    2015-08-08

    The cause-effect relationships between physicochemical properties of amphiphilic [60]fullerene derivatives and their toxicity against bacterial cells have not yet been clarified. In this study, we report how the differences in the chemical structure of organic addends in 10 originally synthesized penta-substituted [60]fullerene derivatives modulate their zeta potential and aggregate's size in salt-free and salt-added aqueous suspensions as well as how these physicochemical characteristics affect the bioenergetics of freshwater Escherichia coli and marine Photobacterium phosphoreum bacteria. Dynamic light scattering, laser Doppler micro-electrophoresis, agarose gel electrophoresis, atomic force microscopy, and bioluminescence inhibition assay were used to characterize the fullerene aggregation behavior in aqueous solution and their interaction with the bacterial cell surface, following zeta potential changes and toxic effects. Dynamic light scattering results indicated the formation of self-assembled [60]fullerene aggregates in aqueous suspensions. The measurement of the zeta potential of the particles revealed that they have different surface charges. The relationship between these physicochemical characteristics was presented as an exponential regression that correctly described the dependence of the aggregate's size of penta-substituted [60]fullerene derivatives in salt-free aqueous suspension from zeta potential value. The prevalence of DLVO-related effects was shown in salt-added aqueous suspension that decreased zeta potential values and affected the aggregation of [60]fullerene derivatives expressed differently for individual compounds. A bioluminescence inhibition assay demonstrated that the toxic effect of [60]fullerene derivatives against E. coli cells was strictly determined by their positive zeta potential charge value being weakened against P. phosphoreum cells in an aquatic system of high salinity. Atomic force microscopy data suggested that the

  6. Ion-selective electrodes in potentiometric titrations; a new method for processing and evaluating titration data.

    PubMed

    Granholm, Kim; Sokalski, Tomasz; Lewenstam, Andrzej; Ivaska, Ari

    2015-08-12

    A new method to convert the potential of an ion-selective electrode to concentration or activity in potentiometric titration is proposed. The advantage of this method is that the electrode standard potential and the slope of the calibration curve do not have to be known. Instead two activities on the titration curve have to be estimated e.g. the starting activity before the titration begins and the activity at the end of the titration in the presence of large excess of titrant. This new method is beneficial when the analyte is in a complexed matrix or in a harsh environment which affects the properties of the electrode and the traditional calibration procedure with standard solutions cannot be used. The new method was implemented both in a method of linearization based on the Grans's plot and in determination of the stability constant of a complex and the concentration of the complexing ligand in the sample. The new method gave accurate results when using titrations data from experiments with samples of known composition and with real industrial harsh black liquor sample. A complexometric titration model was also developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Microscale Titration in Schools Titration Competition.

    ERIC Educational Resources Information Center

    Clark, Michael J.

    1998-01-01

    Reviews the requirements of the National Titration Competition and describes how a team in a local competition used the technique. Compares microscale titration to conventional titration. Outlines the benefits of employing microscale techniques. (DDR)

  8. Rheological behavior, zeta potential, and accelerated stability tests of Buriti oil (Mauritia flexuosa) emulsions containing lyotropic liquid crystals.

    PubMed

    Zanatta, Cinthia Fernanda; de Faria Sato, Anne Miwa Callejón; de Camargo, Flavio Bueno; Campos, Patrícia Maria Berardo Gonçalves Maia; Rocha-Filho, Pedro Alves

    2010-01-01

    It is well known that the Amazon region presents a huge biodiversity; therefore, countless natural resources are being employed in the production of phytocosmetics and phytomedicines. The purpose of this work was to obtain emulsions produced with Buriti oil and non-ionic surfactants. Two surfactant systems were employed (Steareth-2 associated to Ceteareth-5 and to Ceteareth-20) to produce the emulsions using phase diagram method. Emulsions were obtained by echo-planar imaging method at 75°C. Rheological behavior and zeta potential were evaluated, and accelerated stability tests were performed. All emulsions analyzed presented pseudoplastic behavior. Zeta potential values were obtained between -14.2 and -53.3 mV. The formulations did not show changes in either physical stability, pH, or rheological behavior after accelerated stability tests. Significant differences were observed only after temperature cycling test. Based on these results, the emulsions obtained could be considered as promising delivery systems.

  9. Zeta potentials in the flotation of oxide and silicate minerals.

    PubMed

    Fuerstenau, D W; Pradip

    2005-06-30

    Adsorption of collectors and modifying reagents in the flotation of oxide and silicate minerals is controlled by the electrical double layer at the mineral-water interface. In systems where the collector is physically adsorbed, flotation with anionic or cationic collectors depends on the mineral surface being charged oppositely. Adjusting the pH of the system can enhance or prevent the flotation of a mineral. Thus, the point of zero charge (PZC) of the mineral is the most important property of a mineral in such systems. The length of the hydrocarbon chain of the collector is important because of chain-chain association enhances the adsorption once the surfactant ions aggregate to form hemimicelles at the surface. Strongly chemisorbing collectors are able to induce flotation even when collector and the mineral surface are charged similarly, but raising the pH sufficiently above the PZC can repel chemisorbing collectors from the mineral surface. Zeta potentials can be used to delineate interfacial phenomena in these various systems.

  10. Determination of the intrinsic redox potentials of FeS centers of respiratory complex I from experimental titration curves

    PubMed Central

    Medvedev, Emile S.; Couch, Vernon A.

    2014-01-01

    Recently, Euro et al. [Biochem. 47, 3185 (2008)] have reported titration data for seven of nine FeS redox centers of complex I from E. coli. There is a significant uncertainty in the assignment of the titration data. Four of the titration curves were assigned to N1a, N1b, N6b, and N2 centers; one curve either to N3 or N7; one more either to N4 or N5; and the last one denoted Nx could not be assigned at all. In addition, the assignment of the titration data to N6b/N6a pair is also uncertain. In this paper, using our calculated interaction energies [Couch et al. BBA 1787, 1266 (2009)], we perform statistical analysis of these data, considering a variety of possible assignments, find the best fit, and determine the intrinsic redox potentials of the centers. The intrinsic potentials could be determined with uncertainty of less than ±10 mV at 95% confidence level for best fit assignments. We also find that the best agreement between theoretical and experimental titration curves is obtained with the N6b-N2 interaction equal to 71±14 or 96±26 mV depending on the N6b/N6a titration data assignment, which is stronger than was expected and may indicate a close distance of N2 center to the membrane surface. PMID:20513348

  11. Manufacturing of a Secretoneurin Drug Delivery System with Self-Assembled Protamine Nanoparticles by Titration

    PubMed Central

    Scheicher, Bernhard; Lorenzer, Cornelia; Gegenbauer, Katrin; Partlic, Julia; Andreae, Fritz; Kirsch, Alexander H.; Rosenkranz, Alexander R.; Werzer, Oliver

    2016-01-01

    Since therapeutic peptides and oligonucleotides are gathering interests as active pharmaceutical ingredients (APIs), nanoparticulate drug delivery systems are becoming of great importance. Thereby, the possibility to design drug delivery systems according to the therapeutic needs of APIs enhances clinical implementation. Over the last years, the focus of our group was laid on protamine-oligonucleotide-nanoparticles (so called proticles), however, the possibility to modify the size, zeta potential or loading efficiencies was limited. Therefore, at the present study we integrated a stepwise addition of protamine (titration) into the formation process of proticles loaded with the angiogenic neuropeptide secretoneurin (SN). A particle size around 130 nm was determined when proticles were assembled by the commonly used protamine addition at once. Through application of the protamine titration process it was possible to modify and adjust the particle size between approx. 120 and 1200 nm (dependent on mass ratio) without influencing the SN loading capacity. Dynamic light scattering pointed out that the difference in particle size was most probably the result of a secondary aggregation. Initially-formed particles of early stages in the titration process aggregated towards bigger assemblies. Atomic-force-microscopy images also revealed differences in morphology along with different particle size. In contrast, the SN loading was only influenced by the applied mass ratio, where a slight saturation effect was observable. Up to 65% of deployed SN could be imbedded into the proticle matrix. An in-vivo biodistribution study (i.m.) showed a retarded distribution of SN from the site of injection after the application of a SN-proticle formulation. Further, it was demonstrated that SN loaded proticles can be successfully freeze-dried and resuspended afterwards. To conclude, the integration of the protamine titration process offers new possibilities for the formulation of proticles in

  12. Zeta potential and Raman studies of PVP capped Bi2S3 nanoparticles synthesized by polyol method

    NASA Astrophysics Data System (ADS)

    Tarachand, Sathe, Vasant G.; Okram, Gunadhor S.

    2018-05-01

    Here we report the synthesis and characterisation of polyvinylpyrrolidone (PVP) capped Bi2S3 nanoparticles via one step catalyst-free polyol method. Raman spectroscopy, dynamic light scattering and zeta potential analysis were performed on it. Rietveld refinement of powder XRD of PVP capped samples confirmed the formation of single phase orthorhombic Bi2S3 for all PVP capped samples. The presence of eight obvious Raman modes further confirmed the formation of stoichiometric Bi2S3. Dynamic light scattering (DLS) studies show a clear increase in hydrodynamic diameter for samples made with increasing PVP concentration. Particle size obtained from DLS and XRD (using Scherrer's formula) combine with change in full width half maxima of Raman modes collectively suggest overall improvement in crystallinity and quality of product on introducing PVP. In zeta potential (ζ) measurement, steric hindrance of carbon chains plays very crucial role and a systematic reduction of ζ value is observed for samples made with decreasing PVP concentration. An isoelectric point is obtained for sample made with low PVP (1g). Present results are likely to open a window for its medical and catalytic applications.

  13. Effective charges and zeta potentials of oil in water microemulsions in the presence of Hofmeister salts.

    PubMed

    Dos Santos, Alexandre P; Levin, Yan

    2018-06-14

    We present a theory which allows us to calculate the effective charge and zeta potential of oil droplets in microemulsions containing Hofmeister salts. A modified Poisson-Boltzmann equation is used to account for the surface and ion polarizations and hydrophobic and dispersion interactions. The ions are classified as kosmotropes and chaotropes according to their Jones-Dole viscosity B coefficient. Kosmotropes stay hydrated and do not enter into the oil phase, while chaotropes can adsorb to the oil-water interface. The effective interaction potentials between ions and oil-water interface are parametrized so as to accurately account for the excess interfacial tension.

  14. Effective charges and zeta potentials of oil in water microemulsions in the presence of Hofmeister salts

    NASA Astrophysics Data System (ADS)

    dos Santos, Alexandre P.; Levin, Yan

    2018-06-01

    We present a theory which allows us to calculate the effective charge and zeta potential of oil droplets in microemulsions containing Hofmeister salts. A modified Poisson-Boltzmann equation is used to account for the surface and ion polarizations and hydrophobic and dispersion interactions. The ions are classified as kosmotropes and chaotropes according to their Jones-Dole viscosity B coefficient. Kosmotropes stay hydrated and do not enter into the oil phase, while chaotropes can adsorb to the oil-water interface. The effective interaction potentials between ions and oil-water interface are parametrized so as to accurately account for the excess interfacial tension.

  15. Hydrogen bonding and interparticle forces in platelet alpha-Al2O3 dispersions: yield stress and zeta potential.

    PubMed

    Khoo, Kay-Sen; Teh, E-Jen; Leong, Yee-Kwong; Ong, Ban Choon

    2009-04-09

    Adsorbed phosphate on smooth platelet alpha-Al2O3 particles at saturation surface coverage gives rise to strong interparticle attractive forces in dispersion. The maximum yield stress at the point of zero charge was increased by 2-fold. This was attributed to a high density of intermolecular hydrogen bonding between the adsorbed phosphate layers of the interacting particles. Adsorbed citrate at saturation surface coverage, however, reduced the maximum yield stress by 50%. It adsorbed to form a very effective steric barrier as intramolecular hydrogen bonding between -OH and the free terminal carboxylic group prevented strong interactions with other adsorbed citrate molecules residing on the second interacting particle. This steric barrier kept the interacting platelet particles further apart, thereby weakening the van der Waals attraction. The platelet alpha-Al2O3 dispersions were flocculated at all pH level. These dispersions displayed a maximum yield stress at the point of zero zeta potential at the pH approximately 8.0. They also obeyed the yield stress-DLVO force model as characterized by a linear decrease in the yield stress with the square of the zeta potential.

  16. Effect of zeta potential on the performance of a ring-type electroosmotic mixer.

    PubMed

    Kim, T A; Koo, K H; Kim, Y J

    2009-12-01

    In order to achieve faster mixing, a new type of electrokinetic mixer with a T-type channel is introduced. The proposed mixer takes two fluids from different inlets and combines them into a single channel. The fluids then enter a mixing chamber with different inner and outer radii. Four microelectrodes are positioned on the outer wall of the mixing chamber. The electric potentials on the four microelectrodes are sinusoidal with respect to time and have various maximum voltages, zeta potentials and frequency values. The working fluid is water and each inlet has a different initial concentration values. The incompressible Navier-Stokes equation is solved in the channel, with a slip boundary condition on the inner and outer walls of the mixing chamber. The convection-diffusion equation is used to describe the concentration of the dissolved substances in the fluid. The pressure, concentration and flow fields in the channel are calculated and the results are graphically depicted for various flow and electric conditions.

  17. An Olfactory Indicator for Acid-Base Titrations.

    ERIC Educational Resources Information Center

    Flair, Mark N.; Setzer, William N.

    1990-01-01

    The use of an olfactory acid-base indicator in titrations for visually impaired students is discussed. Potential olfactory indicators include eugenol, thymol, vanillin, and thiophenol. Titrations performed with each indicator with eugenol proved to be successful. (KR)

  18. Surfactants, not size or zeta-potential influence blood-brain barrier passage of polymeric nanoparticles.

    PubMed

    Voigt, Nadine; Henrich-Noack, Petra; Kockentiedt, Sarah; Hintz, Werner; Tomas, Jürgen; Sabel, Bernhard A

    2014-05-01

    Nanoparticles (NP) can deliver drugs across the blood-brain barrier (BBB), but little is known which of the factors surfactant, size and zeta-potential are essential for allowing BBB passage. To this end we designed purpose-built fluorescent polybutylcyanoacrylate (PBCA) NP and imaged the NP's passage over the blood-retina barrier - which is a model of the BBB - in live animals. Rats received intravenous injections of fluorescent PBCA-NP fabricated by mini-emulsion polymerisation to obtain various NP's compositions that varied in surfactants (non-ionic, anionic, cationic), size (67-464nm) and zeta-potential. Real-time imaging of retinal blood vessels and retinal tissue was carried out with in vivo confocal neuroimaging (ICON) before, during and after NP's injection. Successful BBB passage with subsequent cellular labelling was achieved if NP were fabricated with non-ionic surfactants or cationic stabilizers but not when anionic compounds were added. NP's size and charge had no influence on BBB passage and cell labelling. This transport was not caused by an unspecific opening of the BBB because control experiments with injections of unlabelled NP and fluorescent dye (to test a "door-opener" effect) did not lead to parenchymal labelling. Thus, neither NP's size nor chemo-electric charge, but particle surface is the key factor determining BBB passage. This result has important implications for NP engineering in medicine: depending on the surfactant, NP can serve one of two opposite functions: while non-ionic tensides enhance brain up-take, addition of anionic tensides prevents it. NP can now be designed to specifically enhance drug delivery to the brain or, alternatively, to prevent brain penetration so to reduce unwanted psychoactive effects of drugs or prevent environmental nanoparticles from entering tissue of the central nervous system. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Signal processing with a summing operational amplifier in multicomponent potentiometric titrations.

    PubMed

    Parczewski, A

    1987-06-01

    It has been proved that application of two indicator electrodes connected to the ordinary titration apparatus through an auxiliary electronic device (a summing operational amplifier) significantly extends the scope of multicomponent potentiometric titrations in which the analytes are determined simultaneously from a single titration curve. For each analyte there is a corresponding potential jump on the titration curve. By application of the proposed auxiliary device, the sum of the electrode potentials is measured. The device also enables the relative sizes of the potential jumps at the end-points on the titration curve to be varied. The advantages of the proposed signal processing are exemplified by complexometric potentiometric titrations of Fe(III) and Cu(II) in mixtures, with a platinum electrode and a copper ion-selective electrode as the indicator electrodes.

  20. Generation of nanobubbles by ceramic membrane filters: The dependence of bubble size and zeta potential on surface coating, pore size and injected gas pressure.

    PubMed

    Ahmed, Ahmed Khaled Abdella; Sun, Cuizhen; Hua, Likun; Zhang, Zhibin; Zhang, Yanhao; Zhang, Wen; Marhaba, Taha

    2018-07-01

    Generation of gaseous nanobubbles (NBs) by simple, efficient, and scalable methods is critical for industrialization and applications of nanobubbles. Traditional generation methods mainly rely on hydrodynamic, acoustic, particle, and optical cavitation. These generation processes render issues such as high energy consumption, non-flexibility, and complexity. This research investigated the use of tubular ceramic nanofiltration membranes to generate NBs in water with air, nitrogen and oxygen gases. This system injects pressurized gases through a tubular ceramic membrane with nanopores to create NBs. The effects of membrane pores size, surface energy, and the injected gas pressures on the bubble size and zeta potential were examined. The results show that the gas injection pressure had considerable effects on the bubble size, zeta potential, pH, and dissolved oxygen of the produced NBs. For example, increasing the injection air pressure from 69 kPa to 414 kPa, the air bubble size was reduced from 600 to 340 nm respectively. Membrane pores size and surface energy also had significant effects on sizes and zeta potentials of NBs. The results presented here aim to fill out the gaps of fundamental knowledge about NBs and development of efficient generation methods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Cellular internalization of polycation-coated microparticles and its dependence on their zeta potential

    NASA Astrophysics Data System (ADS)

    Kato, Noritaka; Kondo, Ryosuke

    2018-03-01

    By applying microparticles to HeLa cells, the number of particles adhered on the cell and that of the ones internalized in the cells were evaluated. Three-dimensional tomographic images of the cells with the particles were obtained by multiphoton excitation laser scanning microscopy, and the adhered and internalized particles were counted separately. When the surface charge of the particles was reversed from negative to positive by coating the particles with polycations, both numbers significantly increased owing to the electrostatic attraction between the cells and the polycation-coated particles. Four different positively charged particles were prepared using four different polycations, and the numbers of adhered and internalized particles were compared. Our results suggest that these numbers depended on the zeta potential rather than the molecular structure of the polycation.

  2. Titration Techniques

    NASA Astrophysics Data System (ADS)

    Jacobsen, Jerrold J.; Houston Jetzer, Kelly; Patani, Néha; Zimmerman, John; Zweerink, Gerald

    1995-07-01

    Significant attention is paid to the proper technique for reading a meniscus. Video shows meniscus-viewing techniques for colorless and dark liquids and the consequences of not reading a meniscus at eye level. Lessons are provided on approaching the end point, focusing on end point colors produced via different commonly used indicators. The concept of a titration curve is illustrated by means of a pH meter. Carefully recorded images of the entire range of meniscus values in a buret, pipet, and graduated cylinder are included so that you can show your students, in lecture or pre-lab discussion, any meniscus and discuss how to read the buret properly. These buret meniscus values are very carefully recorded at the rate of one video frame per hundredth of a milliliter, so that an image showing any given meniscus value can be obtained. These images can be easily incorporated into a computer-based multimedia environment for testing or meniscus-reading exercises. Two of the authors have used this technique and found the exercise to be very well received by their students. Video on side two shows nearly 100 "bloopers", demonstrating both the right way and wrong ways to do tasks associated with titration. This material can be used in a variety of situations: to show students the correct way to do something; to test students by asking them "What is this person doing wrong?"; or to develop multimedia, computer-based lessons. The contents of Titration Techniques are listed below: Side 1 Titration: what it is. A simple titration; Acid-base titration animation; A brief redox titration; Redox titration animation; A complete acid-base titration. Titration techniques. Hand technique variations; Stopcock; Using a buret to measure liquid volumes; Wait before reading meniscus; Dirty and clean burets; Read meniscus at eye level (see Fig. 1); Meniscus viewing techniques--light colored liquids; Meniscus viewing techniques--dark liquids; Using a magnetic stirrer; Rough titration

  3. Risks and Benefits of Rapid Clozapine Titration.

    PubMed

    Lochhead, Jeannie D; Nelson, Michele A; Schneider, Alan L

    2016-05-18

    Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS) during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  4. Stabilization of the initial electrochemical potential for a metal-based potentiometric titration study of a biosorption process.

    PubMed

    Naja, Ghinwa; Mustin, Christian; Volesky, Bohumil; Berthelin, Jacques

    2006-01-01

    An interactive metal-based potentiometric titration method has been developed using an ion selective electrode for studying the sorption of metal cations. The accuracy of this technique was verified by analyzing the metal sorption mechanism for the biomass of Rhizopus arrhizus fungus and diatomite, two dissimilar materials (organic and mineral, strong sorbent and weak sorbent) of a different order of cation exchange capacity. The problem of the initial electrochemical potential was addressed identifying the usefulness of a Na-sulfonic resin as a strong chelating agent applied before the beginning of sorption titration experiments so that the titration curves and the sorption uptake could be quantitatively compared. The resin stabilized the initial electrochemical potential to -405+/-5 mV corresponding to 2 micro gl(-1) of lead concentration in solution. The amounts of lead sorbed by R. arrhizus biomass and diatomite were 0.9 mmol g(-1) (C(e)=5.16 x 10(-2)mM) and 0.052 mmol g(-1) (C(e)=5.97 x 10(-2) mM), respectively. Lead sorption by the fungal biomass was pinpointed to at least two types of chemical active sites. The first type was distinguished by high reactivity and a low number of sites whereas the other was characterized by their higher number and lower reactivity.

  5. The Isolation of DNA by Polycharged Magnetic Particles: An Analysis of the Interaction by Zeta Potential and Particle Size

    PubMed Central

    Haddad, Yazan; Xhaxhiu, Kledi; Kopel, Pavel; Hynek, David; Zitka, Ondrej; Adam, Vojtech

    2016-01-01

    Magnetic isolation of biological targets is in major demand in the biotechnology industry today. This study considers the interaction of four surface-modified magnetic micro- and nanoparticles with selected DNA fragments. Different surface modifications of nanomaghemite precursors were investigated: MAN37 (silica-coated), MAN127 (polyvinylpyrrolidone-coated), MAN158 (phosphate-coated), and MAN164 (tripolyphosphate-coated). All particles were positive polycharged agglomerated monodispersed systems. Mean particle sizes were 0.48, 2.97, 2.93, and 3.67 μm for MAN37, MAN127, MAN164, and MAN158, respectively. DNA fragments exhibited negative zeta potential of −0.22 mV under binding conditions (high ionic strength, low pH, and dehydration). A decrease in zeta potential of particles upon exposure to DNA was observed with exception of MAN158 particles. The measured particle size of MAN164 particles increased by nearly twofold upon exposure to DNA. Quantitative PCR isolation of DNA with a high retrieval rate was observed by magnetic particles MAN127 and MAN164. Interaction between polycharged magnetic particles and DNA is mediated by various binding mechanisms such as hydrophobic and electrostatic interactions. Future development of DNA isolation technology requires an understanding of the physical and biochemical conditions of this process. PMID:27104527

  6. Joule heating effects on electromagnetohydrodynamic flow through a peristaltically induced micro-channel with different zeta potential and wall slip

    NASA Astrophysics Data System (ADS)

    Ranjit, N. K.; Shit, G. C.

    2017-09-01

    This paper aims to develop a mathematical model for magnetohydrodynamic flow of biofluids through a hydrophobic micro-channel with periodically contracting and expanding walls under the influence of an axially applied electric field. The velocity slip effects have been taken into account at the channel walls by employing different slip lengths due to hydrophobic gating. Different temperature jump factors have also been used to investigate the thermomechanical interactions at the fluid-solid interface. The electromagnetohydrodynamic flow in a microchannel is simplified under the framework of Debye-Hückel linearization approximation. We have derived the closed-form solutions for the linearized dimensionless boundary value problem under the assumptions of long wave length and low Reynolds number. The axial velocity, temperature, pressure distribution, stream function, wall shear stress and the Nusselt number have been appraised for diverse values of the parameters approaching into the problem. Our main focus is to determine the effects of different zeta potential on the axial velocity and temperature distribution under electromagnetic environment. This study puts forward an important observation that the different zeta potential plays an important role in controlling fluid velocity. The study further reveals that the temperature increases significantly with the Joule heating parameter and the Brinkman number (arises due to the dissipation of energy).

  7. The Isolation of DNA by Polycharged Magnetic Particles: An Analysis of the Interaction by Zeta Potential and Particle Size.

    PubMed

    Haddad, Yazan; Xhaxhiu, Kledi; Kopel, Pavel; Hynek, David; Zitka, Ondrej; Adam, Vojtech

    2016-04-20

    Magnetic isolation of biological targets is in major demand in the biotechnology industry today. This study considers the interaction of four surface-modified magnetic micro- and nanoparticles with selected DNA fragments. Different surface modifications of nanomaghemite precursors were investigated: MAN37 (silica-coated), MAN127 (polyvinylpyrrolidone-coated), MAN158 (phosphate-coated), and MAN164 (tripolyphosphate-coated). All particles were positive polycharged agglomerated monodispersed systems. Mean particle sizes were 0.48, 2.97, 2.93, and 3.67 μm for MAN37, MAN127, MAN164, and MAN158, respectively. DNA fragments exhibited negative zeta potential of -0.22 mV under binding conditions (high ionic strength, low pH, and dehydration). A decrease in zeta potential of particles upon exposure to DNA was observed with exception of MAN158 particles. The measured particle size of MAN164 particles increased by nearly twofold upon exposure to DNA. Quantitative PCR isolation of DNA with a high retrieval rate was observed by magnetic particles MAN127 and MAN164. Interaction between polycharged magnetic particles and DNA is mediated by various binding mechanisms such as hydrophobic and electrostatic interactions. Future development of DNA isolation technology requires an understanding of the physical and biochemical conditions of this process.

  8. A new biphasic osteoinductive calcium composite material with a negative Zeta potential for bone augmentation

    PubMed Central

    Smeets, Ralf; Kolk, Andreas; Gerressen, Marcus; Driemel, Oliver; Maciejewski, Oliver; Hermanns-Sachweh, Benita; Riediger, Dieter; Stein, Jamal M

    2009-01-01

    The aim of the present study was to analyze the osteogenic potential of a biphasic calcium composite material (BCC) with a negative surface charge for maxillary sinus floor augmentation. In a 61 year old patient, the BCC material was used in a bilateral sinus floor augmentation procedure. Six months postoperative, a bone sample was taken from the augmented regions before two titanium implants were inserted at each side. We analyzed bone neoformation by histology, bone density by computed tomography, and measured the activity of voltage-activated calcium currents of osteoblasts and surface charge effects. Control orthopantomograms were carried out five months after implant insertion. The BCC was biocompatible and replaced by new mineralized bone after being resorbed completely. The material demonstrated a negative surface charge (negative Zeta potential) which was found to be favorable for bone regeneration and osseointegration of dental implants. PMID:19523239

  9. A Closer Look at Acid-Base Olfactory Titrations

    ERIC Educational Resources Information Center

    Neppel, Kerry; Oliver-Hoyo, Maria T.; Queen, Connie; Reed, Nicole

    2005-01-01

    Olfactory titrations using raw onions and eugenol as acid-base indicators are reported. An in-depth investigation on olfactory titrations is presented to include requirements for potential olfactory indicators and protocols for using garlic, onions, and vanillin as acid-base olfactory indicators are tested.

  10. Surfactant titration of nanoparticle-protein corona.

    PubMed

    Maiolo, Daniele; Bergese, Paolo; Mahon, Eugene; Dawson, Kenneth A; Monopoli, Marco P

    2014-12-16

    Nanoparticles (NP), when exposed to biological fluids, are coated by specific proteins that form the so-called protein corona. While some adsorbing proteins exchange with the surroundings on a short time scale, described as a "dynamic" corona, others with higher affinity and long-lived interaction with the NP surface form a "hard" corona (HC), which is believed to mediate NP interaction with cellular machineries. In-depth NP protein corona characterization is therefore a necessary step in understanding the relationship between surface layer structure and biological outcomes. In the present work, we evaluate the protein composition and stability over time and we systematically challenge the formed complexes with surfactants. Each challenge is characterized through different physicochemical measurements (dynamic light scattering, ζ-potential, and differential centrifugal sedimentation) alongside proteomic evaluation in titration type experiments (surfactant titration). 100 nm silicon oxide (Si) and 100 nm carboxylated polystyrene (PS-COOH) NPs cloaked by human plasma HC were titrated with 3-[(3-Cholamidopropyl) dimethylammonio]-1-propanesulfonate (CHAPS, zwitterionic), Triton X-100 (nonionic), sodium dodecyl sulfate (SDS, anionic), and dodecyltrimethylammonium bromide (DTAB, cationic) surfactants. Composition and density of HC together with size and ζ-potential of NP-HC complexes were tracked at each step after surfactant titration. Results on Si NP-HC complexes showed that SDS removes most of the HC, while DTAB induces NP agglomeration. Analogous results were obtained for PS NP-HC complexes. Interestingly, CHAPS and Triton X-100, thanks to similar surface binding preferences, enable selective extraction of apolipoprotein AI (ApoAI) from Si NP hard coronas, leaving unaltered the dispersion physicochemical properties. These findings indicate that surfactant titration can enable the study of NP-HC stability through surfactant variation and also selective separation

  11. Measurements and theoretical interpretation of points of zero charge/potential of BSA protein.

    PubMed

    Salis, Andrea; Boström, Mathias; Medda, Luca; Cugia, Francesca; Barse, Brajesh; Parsons, Drew F; Ninham, Barry W; Monduzzi, Maura

    2011-09-20

    The points of zero charge/potential of proteins depend not only on pH but also on how they are measured. They depend also on background salt solution type and concentration. The protein isoelectric point (IEP) is determined by electrokinetical measurements, whereas the isoionic point (IIP) is determined by potentiometric titrations. Here we use potentiometric titration and zeta potential (ζ) measurements at different NaCl concentrations to study systematically the effect of ionic strength on the IEP and IIP of bovine serum albumin (BSA) aqueous solutions. It is found that high ionic strengths produce a shift of both points toward lower (IEP) and higher (IIP) pH values. This result was already reported more than 60 years ago. At that time, the only available theory was the purely electrostatic Debye-Hückel theory. It was not able to predict the opposite trends of IIP and IEP with ionic strength increase. Here, we extend that theory to admit both electrostatic and nonelectrostatic (NES) dispersion interactions. The use of a modified Poisson-Boltzmann equation for a simple model system (a charge regulated spherical colloidal particle in NaCl salt solutions), that includes these ion specific interactions, allows us to explain the opposite trends observed for isoelectric point (zero zeta potential) and isoionic point (zero protein charge) of BSA. At higher concentrations, an excess of the anion (with stronger NES interactions than the cation) is adsorbed at the surface due to an attractive ionic NES potential. This makes the potential relatively more negative. Consequently, the IEP is pushed toward lower pH. But the charge regulation condition means that the surface charge becomes relatively more positive as the surface potential becomes more negative. Consequently, the IIP (measuring charge) shifts toward higher pH as concentration increases, in the opposite direction from the IEP (measuring potential). © 2011 American Chemical Society

  12. Optimal MEMS device for mobility and zeta potential measurements using DC electrophoresis.

    PubMed

    Karam, Pascal R; Dukhin, Andrei; Pennathur, Sumita

    2017-05-01

    We have developed a novel microchannel geometry that allows us to perform simple DC electrophoresis to measure the electrophoretic mobility and zeta potential of analytes and particles. In standard capillary geometries, mobility measurements using DC fields are difficult to perform. Specifically, measurements in open capillaries require knowledge of the hard to measure and often dynamic wall surface potential. Although measurements in closed capillaries eliminate this requirement, the measurements must be performed at infinitesimally small regions of zero flow where the pressure driven-flow completely cancels the electroosmotic flow (Komagata Planes). Furthermore, applied DC fields lead to electrode polarization, further questioning the reliability and accuracy of the measurement. In contrast, our geometry expands and moves the Komagata planes to where velocity gradients are at a minimum, and thus knowledge of the precise location of a Komagata plane is not necessary. Additionally, our microfluidic device prevents electrode polarization because of fluid recirculation around the electrodes. We fabricated our device using standard MEMS fabrication techniques and performed electrophoretic mobility measurements on 500 nm fluorescently tagged polystyrene particles at various buffer concentrations. Results are comparable to two different commercial dynamic light scattering based particle sizing instruments. We conclude with guidelines to further develop this robust electrophoretic tool that allows for facile and efficient particle characterization. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Design and assembly of ternary Pt/Re/SnO2 NPs by controlling the zeta potential of individual Pt, Re, and SnO2 NPs

    NASA Astrophysics Data System (ADS)

    Drzymała, Elżbieta; Gruzeł, Grzegorz; Pajor-Świerzy, Anna; Depciuch, Joanna; Socha, Robert; Kowal, Andrzej; Warszyński, Piotr; Parlinska-Wojtan, Magdalena

    2018-05-01

    In this study Pt, Re, and SnO2 nanoparticles (NPs) were combined in a controlled manner into binary and ternary combinations for a possible application for ethanol oxidation. For this purpose, zeta potentials as a function of the pH of the individual NPs solutions were measured. In order to successfully combine the NPs into Pt/SnO2 and Re/SnO2 NPs, the solutions were mixed together at a pH guaranteeing opposite zeta potentials of the metal and oxide NPs. The individually synthesized NPs and their binary/ternary combinations were characterized by Fourier transform infrared spectroscopy (FTIR) and scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) analysis. FTIR and XPS spectroscopy showed that the individually synthesized Pt and Re NPs are metallic and the Sn component was oxidized to SnO2. STEM showed that all NPs are well crystallized and the sizes of the Pt, Re, and SnO2 NPs were 2.2, 1.0, and 3.4 nm, respectively. Moreover, EDS analysis confirmed the successful formation of binary Pt/SnO2 and Re/SnO2 NP, as well as ternary Pt/Re/SnO2 NP combinations. This study shows that by controlling the zeta potential of individual metal and oxide NPs, it is possible to assemble them into binary and ternary combinations. [Figure not available: see fulltext.

  14. Thermometric titration of sulphate.

    PubMed

    Williams, M B; Janata, J

    1970-06-01

    Direct thermometric titration of sulphate with a solution of barium perchlorate is proposed. The stoichiometry of the titration is shown to be critically dependent on the concentration of ethanol in the titration medium. The titration is rapid and suffers from only a few interferences.

  15. Variability in Bioreactivity Linked to Changes in Size and Zeta Potential of Diesel Exhaust Particles in Human Immune Cells

    PubMed Central

    Sarkar, Srijata; Zhang, Lin; Subramaniam, Prasad; Lee, Ki-Bum; Garfunkel, Eric; Strickland, Pamela A. Ohman.; Mainelis, Gediminas; Lioy, Paul J.; Tetley, Teresa D.; Chung, Kian Fan; Zhang, Junfeng; Ryan, Mary; Porter, Alex; Schwander, Stephan

    2014-01-01

    Acting as fuel combustion catalysts to increase fuel economy, cerium dioxide (ceria, CeO2) nanoparticles have been used in Europe as diesel fuel additives (Envirox™). We attempted to examine the effects of particles emitted from a diesel engine burning either diesel (diesel exhaust particles, DEP) or diesel doped with various concentrations of CeO2 (DEP-Env) on innate immune responses in THP-1 and primary human peripheral blood mononuclear cells (PBMC). Batches of DEP and DEP-Env were obtained on three separate occasions using identical collection and extraction protocols with the aim of determining the reproducibility of particles generated at different times. However, we observed significant differences in size and surface charge (zeta potential) of the DEP and DEP-Env across the three batches. We also observed that exposure of THP-1 cells and PBMC to identical concentrations of DEP and DEP-Env from the three batches resulted in statistically significant differences in bioreactivity as determined by IL-1β, TNF-α, IL-6, IFN-γ, and IL-12p40 mRNA (by qRT-PCR) and protein expression (by ELISPOT assays). Importantly, bioreactivity was noted in very tight ranges of DEP size (60 to 120 nm) and zeta potential (−37 to −41 mV). Thus, these physical properties of DEP and DEP-Env were found to be the primary determinants of the bioreactivity measured in this study. Our findings also point to the potential risk of over- or under- estimation of expected bioreactivity effects (and by inference of public health risks) from bulk DEP use without taking into account potential batch-to-batch variations in physical (and possibly chemical) properties. PMID:24825358

  16. Characterization of gold nanoparticles with different hydrophilic coatings via capillary electrophoresis and Taylor dispersion analysis. Part I: determination of the zeta potential employing a modified analytic approximation.

    PubMed

    Pyell, Ute; Jalil, Alaa H; Pfeiffer, Christian; Pelaz, Beatriz; Parak, Wolfgang J

    2015-07-15

    Taking gold nanoparticles with different hydrophilic coatings as an example, it is investigated whether capillary electrophoresis in combination with Taylor dispersion analysis allows for the precise determination of mean electrophoretic mobilities, electrophoretic mobility distributions, and zeta potentials in a matrix of exactly known composition and the calibration-free determination of number-weighted mean hydrodynamic radii. Our experimental data confirm that the calculation of the zeta potential for colloidal nanoparticles with ζ>25 mV requires to take the relaxation effect into account. Because of the requirement to avoid particle-wall interactions, a solution of disodiumtetraborate decahydrate (borax) in deionized water had been selected as suitable electrolyte. Measurements of the electrophoretic mobility at different ionic strength and application of the analytic approximation developed by Ohshima show that in the present case of a buffered solution with a weak electrolyte co-ion and a strong electrolyte counterion, the effective ionic drag coefficient should be approximated with the ionic drag coefficient of the counterion. The obtained results are in good agreement with theoretical expectations regarding the dependence of the zeta potential and the electrokinetic surface charge density on the ionic strength. We also show that Taylor dispersion analysis (besides estimation of the number-weighted mean hydrodynamic radius) provides additional information on the type and width of the number-weighted particle distribution. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. The receptor protein tyrosine phosphatase (RPTP){beta}/{zeta} is expressed in different subtypes of human breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perez-Pinera, Pablo; Garcia-Suarez, Olivia; Instituto Universitario de Oncologia del Principado de Asturias, Oviedo

    2007-10-12

    Increasing evidence suggests mutations in human breast cancer cells that induce inappropriate expression of the 18-kDa cytokine pleiotrophin (PTN, Ptn) initiate progression of breast cancers to a more malignant phenotype. Pleiotrophin signals through inactivating its receptor, the receptor protein tyrosine phosphatase (RPTP){beta}/{zeta}, leading to increased tyrosine phosphorylation of different substrate proteins of RPTP{beta}/{zeta}, including {beta}-catenin, {beta}-adducin, Fyn, GIT1/Cat-1, and P190RhoGAP. PTN signaling thus has wide impact on different important cellular systems. Recently, PTN was found to activate anaplastic lymphoma kinase (ALK) through the PTN/RPTP{beta}/{zeta} signaling pathway; this discovery potentially is very important, since constitutive ALK activity of nucleophosmin (NPM)-ALK fusionmore » protein is causative of anaplastic large cell lymphomas, and, activated ALK is found in other malignant cancers. Recently ALK was identified in each of 63 human breast cancers from 22 subjects. We now demonstrate that RPTP{beta}/{zeta} is expressed in each of these same 63 human breast cancers that previously were found to express ALK and in 10 additional samples of human breast cancer. RPTP{beta}/{zeta} furthermore was localized not only in its normal association with the cell membrane but also scattered in cytoplasm and in nuclei in different breast cancer cells and, in the case of infiltrating ductal carcinomas, the distribution of RPTP{beta}/{zeta} changes as the breast cancer become more malignant. The data suggest that the PTN/RPTP{beta}/{zeta} signaling pathway may be constitutively activated and potentially function to constitutively activate ALK in human breast cancer.« less

  18. LIGHT TITRATIONS

    PubMed Central

    Field, John; Baas-Becking, Lourens G. M.

    1926-01-01

    1. The usefulness of the radiomicrometer in titration work has been pointed out. The authors suggest that light titration may also be used where a reaction mixture changes its absorption in the (near) infra-red. 2. The applicability of this method to the starch-iodine reaction has been demonstrated. PMID:19872266

  19. Zeta Ophiuchi -- Runaway Star Plowing through Space Dust

    NASA Image and Video Library

    2011-01-24

    The blue star near the center of this image is Zeta Ophiuchi. Zeta Ophiuchi is actually a very massive, hot, bright blue star plowing its way through a large cloud of interstellar dust and gas in this image from NASA Wide-field Infrared Survey Explorer.

  20. A set-up for simultaneous measurement of second harmonic generation and streaming potential and some test applications.

    PubMed

    Lützenkirchen, Johannes; Scharnweber, Tim; Ho, Tuan; Striolo, Alberto; Sulpizi, Marialore; Abdelmonem, Ahmed

    2018-06-15

    We present a measurement cell that allows simultaneous measurement of second harmonic generation (SHG) and streaming potential (SP) at mineral-water interfaces with flat specimen that are suitable for non-linear optical (NLO) studies. The set-up directly yields SHG data for the interface of interest and can also be used to obtain information concerning the influence of flow on NLO signals from that interface. The streaming potential is at present measured against a reference substrate (PTFE). The properties of this inert reference can be independently determined for the same conditions. With the new cell, for the first time the SHG signal and the SP for flat surfaces have been simultaneously measured on the same surface. This can in turn be used to unambiguously relate the two observations for identical solution composition. The SHG test of the cell with a fluorite sample confirmed previously observed differences in NLO signal under flow vs. no flow conditions in sum frequency generation (SFG) investigations. As a second test surface, an inert ("hydrophobic") OTS covered sapphire-c electrolyte interface was studied to verify the zeta-potential measurements with the new cell. For this system we obtained combined zeta-potential/SHG data in the vicinity of the point of zero charge, which were found to be proportional to each other as expected. Furthermore, on the accessible time scales of the SHG measurements no effects of flow, flow velocity and stopped flow occurred on the interfacial water structure. This insensitivity to flow for the inert surface was corroborated by concomitant molecular dynamics simulations. Finally, the set-up was used for simultaneous measurements of the two properties as a function of pH in automated titrations with an oxidic surface. Different polarization combinations obtained in two separate titrations, yielded clearly different SHG data, while under identical conditions zeta-potentials were exactly reproduced. The polarization combination

  1. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    PubMed

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  2. Tracer-monitored flow titrations.

    PubMed

    Sasaki, Milton K; Rocha, Diogo L; Rocha, Fábio R P; Zagatto, Elias A G

    2016-01-01

    The feasibility of implementing tracer-monitored titrations in a flow system is demonstrated. A dye tracer is used to estimate the instant sample and titrant volumetric fractions without the need for volume, mass or peak width measurements. The approach was applied to spectrophotometric flow titrations involving variations of sample and titrant flow-rates (i.e. triangle programmed technique) or concentration gradients established along the sample zone (i.e. flow injection system). Both strategies required simultaneous monitoring of two absorbing species, namely the titration indicator and the dye tracer. Mixing conditions were improved by placing a chamber with mechanical stirring in the analytical path aiming at to minimize diffusional effects. Unlike most of flow-based titrations, the innovation is considered as a true titration, as it does not require a calibration curve thus complying with IUPAC definition. As an application, acidity evaluation in vinegars involving titration with sodium hydroxide was selected. Phenolphthalein and brilliant blue FCF were used as indicator and dye tracer, respectively. Effects of sample volume, titrand/titrant concentrations and flow rates were investigated aiming at improved accuracy and precision. Results were reliable and in agreement with those obtained by a reference titration procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Characterization of the startup transient electrokinetic flow in rectangular channels of arbitrary dimensions, zeta potential distribution, and time-varying pressure gradient.

    PubMed

    Miller, Andrew; Villegas, Arturo; Diez, F Javier

    2015-03-01

    The solution to the startup transient EOF in an arbitrary rectangular microchannel is derived analytically and validated experimentally. This full 2D transient solution describes the evolution of the flow through five distinct periods until reaching a final steady state. The derived analytical velocity solution is validated experimentally for different channel sizes and aspect ratios under time-varying pressure gradients. The experiments used a time resolved micro particle image velocimetry technique to calculate the startup transient velocity profiles. The measurements captured the effect of time-varying pressure gradient fields derived in the analytical solutions. This is tested by using small reservoirs at both ends of the channel which allowed a time-varying pressure gradient to develop with a time scale on the order of the transient EOF. Results showed that under these common conditions, the effect of the pressure build up in the reservoirs on the temporal development of the transient startup EOF in the channels cannot be neglected. The measurements also captured the analytical predictions for channel walls made of different materials (i.e., zeta potentials). This was tested in channels that had three PDMS and one quartz wall, resulting in a flow with an asymmetric velocity profile due to variations in the zeta potential between the walls. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. The interstellar line spectra of zeta Ophiuchi and zeta Persei and their relation to the short wavelength microwave background radiation. Ph.D. Thesis - N. Y. Univ.

    NASA Technical Reports Server (NTRS)

    Bortolot, V. J., Jr.

    1972-01-01

    Thirty-one high dispersion Coude spectrograms of zeta Ophiuchi and seven of zeta Persei were numerically synthesized to produce high resolution, low noise spectra in the interval 3650 A to 4350 that yield data on atomic and molecular absorption in well-defined regions of the interstellar medium. The detection threshold is improved by as much as a factor 5 over single plates. Several interstellar lines were discovered in the zeta Oph - 15km/sec cloud and the zeta Per + 13 km/sec cloud.

  5. Estimation of Nanodiamond Surface Charge Density from Zeta Potential and Molecular Dynamics Simulations.

    PubMed

    Ge, Zhenpeng; Wang, Yi

    2017-04-20

    Molecular dynamics simulations of nanoparticles (NPs) are increasingly used to study their interactions with various biological macromolecules. Such simulations generally require detailed knowledge of the surface composition of the NP under investigation. Even for some well-characterized nanoparticles, however, this knowledge is not always available. An example is nanodiamond, a nanoscale diamond particle with surface dominated by oxygen-containing functional groups. In this work, we explore using the harmonic restraint method developed by Venable et al., to estimate the surface charge density (σ) of nanodiamonds. Based on the Gouy-Chapman theory, we convert the experimentally determined zeta potential of a nanodiamond to an effective charge density (σ eff ), and then use the latter to estimate σ via molecular dynamics simulations. Through scanning a series of nanodiamond models, we show that the above method provides a straightforward protocol to determine the surface charge density of relatively large (> ∼100 nm) NPs. Overall, our results suggest that despite certain limitation, the above protocol can be readily employed to guide the model construction for MD simulations, which is particularly useful when only limited experimental information on the NP surface composition is available to a modeler.

  6. Novel Method for Finding [zeta](2[rho]) from a Product of Sines

    ERIC Educational Resources Information Center

    Osler, Thomas J.

    2006-01-01

    Euler gave a simple method for showing that [zeta](2)=1/1[superscript 2] + 1/2[superscript 2] + 1/3[superscript 2] + ... = [pi][superscript 2]/6. He generalized his method so as to find [zeta](4), [zeta](6), [zeta](8),.... His computations became increasingly more complex as the arguments increased. In this note we show a different generalization…

  7. Rapid clozapine titration in treatment-refractory bipolar disorder.

    PubMed

    Ifteni, Petru; Correll, Christoph U; Nielsen, Jimmi; Burtea, Victoria; Kane, John M; Manu, Peter

    2014-09-01

    Clozapine is effective in treatment-refractory bipolar disorder (BD). Guidelines recommend slow titration to prevent seizures, hypotension and myocarditis, but this stance is not supported by comparative data. To evaluate the safety and effectiveness of rapid clozapine titration in BD. Analysis of a consecutive cohort of treatment-refractory BD patients with mixed/manic episode admitted on alternate days to one of two units of a psychiatric hospital. On one unit, clozapine was started at 25mg followed by 25-50mg as needed every 6h (maximum=100mg/day) on day 1, followed by increases of 25-100mg/day. On the other unit, clozapine was initiated with 25mg in day 1, followed by increases of 25-50mg/day. The primary outcome was the number of days from starting clozapine until readiness for discharge, adjusted in logistic regression for the number of antipsychotics tried during the hospitalization, psychotropic co-treatments and presence of psychotic features. Patients subject to rapid (N=44) and standard (N=23) titration were similar in age, gender, smoking status, body mass index, illness severity at baseline and discharge, and highest clozapine dose. Clozapine was discontinued due to hypotension (N=1) and pneumonia (N=1) during rapid titration, and for excessive sedation (N=1) in each titration group. The number of hospital days from starting clozapine until readiness for discharge was 3.8 days shorter in the rapid titration group (12.7±6.3 vs. 16.5±5.8, p=0.0077). Rapid clozapine titration appeared safe and effective for treatment-refractory BD. The potential for shorter hospital stays justifies prospective trials of this method. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Activation-induced proteolysis of cytoplasmic domain of zeta in T cell receptors and Fc receptors.

    PubMed

    Taupin, J L; Anderson, P

    1994-12-01

    The CD3-T cell receptor (TCR) complex on T cells and the Fc gamma receptor type III (Fc gamma RIII)-zeta-gamma complex on natural killer cells are functionally analogous activation receptors that associate with a family of disulfide-linked dimers composed of the related subunits zeta and gamma. Immunochemical analysis of receptor complexes separated on two-dimensional diagonal gels allowed the identification of a previously uncharacterized zeta-p14 heterodimer. zeta-p14 is a component of both CD3-TCR and Fc gamma RIII-zeta-gamma. Peptide mapping analysis shows that p14 is structurally related to zeta, suggesting that it is either: (i) derived from zeta proteolytically or (ii) the product of an alternatively spliced mRNA. The observation that COS cells transformed with a cDNA encoding zeta express zeta-p14 supports the former possibility. The expression of CD3-TCR complexes including zeta-p14 increases following activation with phorbol 12-myristate 13-acetate or concanavalin A, suggesting that proteolysis of zeta may contribute to receptor modulation or desensitization.

  9. Predicting the influence of liposomal lipid composition on liposome size, zeta potential and liposome-induced dendritic cell maturation using a design of experiments approach.

    PubMed

    Soema, Peter C; Willems, Geert-Jan; Jiskoot, Wim; Amorij, Jean-Pierre; Kersten, Gideon F

    2015-08-01

    In this study, the effect of liposomal lipid composition on the physicochemical characteristics and adjuvanticity of liposomes was investigated. Using a design of experiments (DoE) approach, peptide-containing liposomes containing various lipids (EPC, DOPE, DOTAP and DC-Chol) and peptide concentrations were formulated. Liposome size and zeta potential were determined for each formulation. Moreover, the adjuvanticity of the liposomes was assessed in an in vitro dendritic cell (DC) model, by quantifying the expression of DC maturation markers CD40, CD80, CD83 and CD86. The acquired data of these liposome characteristics were successfully fitted with regression models, and response contour plots were generated for each response factor. These models were applied to predict a lipid composition that resulted in a liposome with a target zeta potential. Subsequently, the expression of the DC maturation factors for this lipid composition was predicted and tested in vitro; the acquired maturation responses corresponded well with the predicted ones. These results show that a DoE approach can be used to screen various lipids and lipid compositions, and to predict their impact on liposome size, charge and adjuvanticity. Using such an approach may accelerate the formulation development of liposomal vaccine adjuvants. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Titration Curves: Fact and Fiction.

    ERIC Educational Resources Information Center

    Chamberlain, John

    1997-01-01

    Discusses ways in which datalogging equipment can enable titration curves to be measured accurately and how computing power can be used to predict the shape of curves. Highlights include sources of error, use of spreadsheets to generate titration curves, titration of a weak acid with a strong alkali, dibasic acids, weak acid and weak base, and…

  11. Synthesis of the RGO/Al2O3 core-shell nanocomposite flakes and characterization of their unique electrostatic properties using zeta potential measurements

    NASA Astrophysics Data System (ADS)

    Jastrzębska, A. M.; Karcz, J.; Letmanowski, R.; Zabost, D.; Ciecierska, E.; Zdunek, J.; Karwowska, E.; Siekierski, M.; Olszyna, A.; Kunicki, A.

    2016-01-01

    The aim of this study was to describe the influence of the modification of electrostatic properties of RGO/Al2O3 core-shell nanocomposite flakes. The amount of crystalline form of aluminum oxide was very small. It existed mostly in amorphous phase in the form of covalently bonded to GO surface. The morphological, structural and physicochemical investigations results showed that spherical Al2O3 nanoparticles (ca. 41 nm) in gamma phase completely covered the surface of curly-shaped RGO flakes and acted as a spreader between individual flakes. The high BET specific surface area of the analyzed composite (119.71 m2/g) together with very low open porosity (0.479 cm3/g) indicated that RGO/Al2O3 nanocomposite flakes showed low tendency to agglomeration. The zeta potential curves obtained for RGO/Al2O3 core-shell nanocomposite flakes were differing from curves obtained for GO and Al2O3 suspensions in distilled water and neutral environment. The specific electrostatic properties of the core-shell system of RGO/Al2O3 flakes had an influence on its surface charge (zeta potential) which was measured by applying an external electric field. The FTIR and Raman investigations results also confirmed that the Cdbnd O species were not taking part in the surface amphoteric reactions resulting in the formation of electrostatic surface charge.

  12. Depression May Reduce Adherence during CPAP Titration Trial

    PubMed Central

    Law, Mandy; Naughton, Matthew; Ho, Sally; Roebuck, Teanau; Dabscheck, Eli

    2014-01-01

    Study Objectives: Depression is a risk factor for medication non-compliance. We aimed to identify if depression is associated with poorer adherence during home-based autotitrating continuous positive airway pressure (autoPAP) titration. Design: Mixed retrospective-observational study. Setting: Academic center. Participants: Two-hundred forty continuous positive airway pressure-naïve obstructive sleep apnea (OSA) patients. Measurements: Patients underwent approximately 1 week of home-based autoPAP titration with adherence data downloaded from the device. Electronic hospital records were reviewed in a consecutive manner for inclusion. Three areas of potential predictors were examined: (i) demographics and clinical factors, (ii) disease severity, and (iii) device-related variables. Depression and anxiety were assessed using the Hospital Anxiety and Depression Scale (HADS). Scores on the subscales were categorized as normal or clinical diagnoses of depression (≥ 8) and anxiety (≥ 11). The primary outcome variable was the mean hours of autoPAP used per night. Results: Patients were diagnosed with OSA by either attended polysomnography (n = 73, AHI 25.5[15.1-41.5]) or unattended home oximetry (n = 167, ODI3 34.0[22.4-57.4]) and had home-based autoPAP titration over 6.2 ± 1.2 nights. Mean autoPAP use was 4.5 ± 2.4 hours per night. Multiple linear regression analysis revealed that depression and lower 95th percentile pressures significantly predicted lesser hours of autoPAP use (R2 = 0.19, p < 0.001). Significantly milder OSA in those requiring lower pressures may have confounded the relationship between 95th percentile pressure and autoPAP use. Conclusion: Depression was independently associated with poorer adherence during home-based autoPAP titration. Depression may be a potential target for clinicians and future research aimed at enhancing adherence to autoPAP therapy. Citation: Law M; Naughton M; Ho S; Roebuck T; Dabscheck E. Depression may reduce adherence

  13. Determining a Solubility Product Constant by Potentiometric Titration to Increase Students' Conceptual Understanding of Potentiometry and Titrations

    ERIC Educational Resources Information Center

    Grabowski, Lauren E.; Goode, Scott R.

    2017-01-01

    Potentiometric titrations are widely taught in first-year undergraduate courses to connect electrochemistry, stoichiometry, and equilibria and to reinforce acid-base titrations. Students perform a potentiometric titration that is then analyzed to determine analyte concentrations and the solubility product constant of the solid species.

  14. Electroconvulsive therapy stimulus titration: Not all it seems.

    PubMed

    Rosenman, Stephen J

    2018-05-01

    To examine the provenance and implications of seizure threshold titration in electroconvulsive therapy. Titration of seizure threshold has become a virtual standard for electroconvulsive therapy. It is justified as individualisation and optimisation of the balance between efficacy and unwanted effects. Present day threshold estimation is significantly different from the 1960 studies of Cronholm and Ottosson that are its usual justification. The present form of threshold estimation is unstable and too uncertain for valid optimisation or individualisation of dose. Threshold stimulation (lowest dose that produces a seizure) has proven therapeutically ineffective, and the multiples applied to threshold to attain efficacy have never been properly investigated or standardised. The therapeutic outcomes of threshold estimation (or its multiples) have not been separated from simple dose effects. Threshold estimation does not optimise dose due to its own uncertainties and the different short-term and long-term cognitive and memory effects. Potential harms of titration have not been examined. Seizure threshold titration in electroconvulsive therapy is not a proven technique of dose optimisation. It is widely held and practiced; its benefit and harmlessness assumed but unproven. It is a prematurely settled answer to an unsettled question that discourages further enquiry. It is an example of how practices, assumed scientific, enter medicine by obscure paths.

  15. Titration Calorimetry Standards and the Precision of Isothermal Titration Calorimetry Data

    PubMed Central

    Baranauskienė, Lina; Petrikaitė, Vilma; Matulienė, Jurgita; Matulis, Daumantas

    2009-01-01

    Current Isothermal Titration Calorimetry (ITC) data in the literature have relatively high errors in the measured enthalpies of protein-ligand binding reactions. There is a need for universal validation standards for titration calorimeters. Several inorganic salt co-precipitation and buffer protonation reactions have been suggested as possible enthalpy standards. The performances of several commercial calorimeters, including the VP-ITC, ITC200, and Nano ITC-III, were validated using these suggested standard reactions. PMID:19582227

  16. Improving medication titration in heart failure by embedding a structured medication titration plan.

    PubMed

    Hickey, Annabel; Suna, Jessica; Marquart, Louise; Denaro, Charles; Javorsky, George; Munns, Andrew; Mudge, Alison; Atherton, John J

    2016-12-01

    To improve up-titration of medications to target dose in heart failure patients by improving communication from hospital to primary care. This quality improvement project was undertaken within three heart failure disease management (HFDM) services in Queensland, Australia. A structured medication plan was collaboratively designed and implemented in an iterative manner, using methods including awareness raising and education, audit and feedback, integration into existing work practice, and incentive payments. Evaluation was undertaken using sequential audits, and included process measures (use of the titration plan, assignment of responsibility) and outcome measures (proportion of patients achieving target dose) in HFDM service patients with reduced left ventricular ejection fraction. Comparison of the three patient cohorts (pre-intervention cohort A n=96, intervention cohort B n=95, intervention cohort C n=89) showed increase use of the titration plan, a shift to greater primary care responsibility for titration, and an increase in the proportion of patients achieving target doses of angiotensin converting enzyme inhibitors/angiotensin receptor blockers (ACEI/ARB) (A 37% vs B 48% vs C 55%, p=0.051) and beta-blockers (A 38% vs B 33% vs C 51%, p=0.045). Combining all three cohorts, patients not on target doses when discharged from hospital were more likely to achieve target doses of ACEI/ARB (p<0.0001) and beta blockers (p<0.0001) within six months if they received a medication titration plan. A medication titration plan was successfully implemented in three HFDM services and improved transitional communication and achievement of target doses of evidence-based therapies within six months of hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Simultaneous addition of two ligands: a potential strategy for estimating divalent ion affinities in EF-hand proteins by isothermal titration calorimetry.

    PubMed

    Henzl, Michael T; Markus, Lindsey A; Davis, Meredith E; McMillan, Andrew T

    2013-03-01

    Capable of providing a detailed thermodynamic picture of noncovalent association reactions, isothermal titration calorimetry (ITC) has become a popular method for studying protein-ligand interactions. We routinely employ the technique to study divalent ion-binding by two-site EF-hand proteins from the parvalbumin- and polcalcin lineages. The combination of high Ca(2+) affinity and relatively low Mg(2+) affinity, and the attendant complication of parameter correlation, conspire to make the simultaneous extraction of binding constants and -enthalpies for both ions challenging. Although global analysis of multiple ITC experiments can overcome these hurdles, our current experimental protocol includes upwards of 10 titrations - requiring a substantial investment in labor, machine time, and material. This paper explores the potential for using a smaller suite of experiments that includes simultaneous titrations with Ca(2+) and Mg(2+) at different ratios of the two ions. The results obtained for four proteins, differing substantially in their divalent ion-binding properties, suggest that the approach has merit. The Ca(2+)- and Mg(2+)-binding constants afforded by the streamlined analysis are in reasonable agreement with those obtained from the standard analysis protocol. Likewise, the abbreviated analysis provides comparable values for the Ca(2+)-binding enthalpies. However, the streamlined analysis can yield divergent values for the Mg(2+)-binding enthalpies - particularly those for lower affinity sites. This shortcoming can be remedied, in large measure, by including data from a direct Ca(2+) titration in the presence of a high, fixed Mg(2+) concentration. Copyright © 2013. Published by Elsevier Inc.

  18. Mixtures of latex particles and the surfactant of opposite charge used as interface stabilizers--influence of particle contact angle, zeta potential, flocculation and shear energy.

    PubMed

    Deleurence, Rémi; Parneix, Caroline; Monteux, Cécile

    2014-09-28

    We investigate the stabilization of air-water interfaces by mixtures of negatively charged latex particles (sulfate polystyrene) and cationic surfactants (alkyl trimethylammonium bromides). First we report results concerning the binding of surfactant molecules to the latex particles. As the surfactant concentration increases, the charge of the particles reverses, from negative to positive, because CnTAB first binds electrostatically to the latex particles and then through hydrophobic interaction with the monolayer already adsorbed on the particles as well as directly with the hydrophobic surface of the latex. Over a large range of surfactant concentrations around the charge inversion, a strong flocculation is observed and 100 μm large aggregates form in the suspension. Unlike previous studies published on mixtures of inorganic particles with oppositely charged surfactants, we show that we can vary the sign of the zeta potential of the particles without changing the contact angle of the particles over a large range of surfactant concentrations. Indeed, the latex particles that we study are more hydrophobic than inorganic particles, hence adding moderate concentrations of the surfactant results in a weak variation of the contact angle while the charge of the particles can be reversed. This enables decoupling of the effect of zeta potential and contact angle on the interfacial properties of the mixtures. Our study shows that the contact angle and the charge of the particles are not sufficient parameters to control the foam properties, and the key-parameters are the flocculation state and the shear energy applied to produce the foam. Indeed, flocculated samples, whatever the sign of the zeta potential, enable production of a stable armour at the interface. The large aggregates do not adsorb spontaneously at the interface because of their large size, however when a large shear energy is used to produce the foam very stable foam is obtained, where particles are trapped

  19. Benefit of slow titration of paroxetine to treat depression in the elderly.

    PubMed

    Olgiati, Paolo; Bajo, Emanuele; Serretti, Alessandro

    2014-11-01

    Paroxetine is commonly used to treat depression in the elderly; however, titration issues have been raised. Rapid titration may lead to increased anxiety and early dropout. The aim of this cost-utility analysis was to compare the potential benefit of standard (10 mg the first day) versus slow titration (2.5 mg gradually increased). Clinical analysis was based on a naturalistic trial integrated with a decision-analytic model representing second treatments for those who initially did not respond and for dropout cases. Treatment setting was a public outpatient center for mental disorders in Italy. Service use data were estimated from best practice guidelines, whereas costs (Euros; 2012) were retrieved from Italian official sources. Slow titration approach produced 0.031 more quality-adjusted life years (remission rate: 57% vs 44% in standard titration group) at an incremental cost of €5.53 (generic paroxetine) and €54.54 (brand paroxetine syrup). Incremental cost-effectiveness ratio (ICER) values were €159 and €1768, respectively, in favor of slow titration approach. Cost-effectiveness threshold, defined as ICER < 1 GDP per capita according to World Health Organization criteria, is about €25 000 in Italy. Our results are consistent with a superiority of slow titration of paroxetine in older depressed patients. However, these findings, in part based on simulated data, need to be replicated in clinical trials. Copyright © 2014 John Wiley & Sons, Ltd.

  20. The use of zeta potential as a tool to study phase transitions in binary phosphatidylcholines mixtures.

    PubMed

    Sierra, M B; Pedroni, V I; Buffo, F E; Disalvo, E A; Morini, M A

    2016-06-01

    Temperature dependence of the zeta potential (ZP) is proposed as a tool to analyze the thermotropic behavior of unilamellar liposomes prepared from binary mixtures of phosphatidylcholines in the absence or presence of ions in aqueous suspensions. Since the lipid phase transition influences the surface potential of the liposome reflecting a sharp change in the ZP during the transition, it is proposed as a screening method for transition temperatures in complex systems, given its high sensitivity and small amount of sample required, that is, 70% less than that required in the use of conventional calorimeters. The sensitivity is also reflected in the pre-transition detection in the presence of ions. Plots of phase boundaries for these mixed-lipid vesicles were constructed by plotting the delimiting temperatures of both main phase transition and pre-transition vs. the lipid composition of the vesicle. Differential scanning calorimetry (DSC) studies, although subject to uncertainties in interpretation due to broad bands in lipid mixtures, allowed the validation of the temperature dependence of the ZP method for determining the phase transition and pre-transition temperatures. The system chosen was dipalmitoylphosphatidylcholine/dimyristoyl phosphatidylcholine (DMPC/DPPC), the most common combination in biological membranes. This work may be considered as a starting point for further research into more complex lipid mixtures with functional biological importance. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. A gene variation of 14-3-3 zeta isoform in rat hippocampus.

    PubMed

    Murakami, K; Situ, S Y; Eshete, F

    1996-11-14

    A variant form of 14-3-3 zeta was isolated from the rat hippocampal cDNA library. The cloned cDNA is 1687 bp in length and it contains an entire ORF (nt = 63-797) with 245 amino acids that is characteristic to 14-3-3 zeta subtype. By comparing with reported sequences of 14-3-3 zeta, we found three nucleotide substitutions within the coding sequence in our clone; C<-->T transition at nt = 325 and G<-->C transversions at nt = 387 and 388. Both are missense mutations, leading ACG (Thr) to ATG (Met) and CGT (Arg) to GCT (Ala) conversions at residue 88 and 109, respectively. Our results show that at least three different genetic variants of 14-3-3 zeta are present in rat species which results in protein variations. Such mutation in the amino acid sequence is an important indication of the diverse functions of this protein and may also contribute to the recent contradictory observations regarding the role of the 14-3-3 zeta subtype.

  2. Potentiometric titration of metal ions in ethanol.

    PubMed

    Gibson, Graham T T; Mohamed, Mark F; Neverov, Alexei A; Brown, R S

    2006-09-18

    The potentiometric titrations of Zn2+, Cu2+ and 12 Ln3+ metal ions were obtained in ethanol to determine the titration constants (defined as the at which the [-OEt]/[Mx+]t ratios are 0.5, 1.5, and 2.5) and in two cases (La3+ and Zn2+) a complete speciation diagram. Several simple monobasic acids and aminium ions were also titrated to test the validity of experimental titration measurements and to establish new constants in this medium that will be useful for the preparation of buffers and standard solutions. The dependence of the titration constants on the concentration and type of metal ion and specific counterion effects is discussed. In selected cases, the titration profiles were analyzed using a commercially available fitting program to obtain information about the species present in solution, including La3+ for which a dimer model is proposed. The fitting provides the microscopic values for deprotonation of one to four metal-bound ethanol molecules. Kinetics for the La3+-catalyzed ethanolysis of paraoxon as a function of are presented and analyzed in terms of La3+ speciation as determined by the analysis of potentiometric titration curves. The stability constants for the formation of Zn2+ and Cu2+ complexes with 1,5,9-triazacyclododecane as determined by potentiometric titration are presented.

  3. Zeta Potential Measurements on Three Clays from Turkey and Effects of Clays on Coal Flotation

    PubMed

    Hussain; Dem&idot;rc&idot;; özbayoğlu

    1996-12-25

    There is a growing trend of characterizing coal and coal wastes in order to study the effect of clays present in them during coal washing. Coarse wastes from the Zonguldak Coal Washery, Turkey, were characterized and found to contain kaolinite, illite, and chlorite. These three clays, obtained in almost pure form from various locations in Turkey, have been subjected to X-ray diffraction (XRD) analysis to assess their purity and zeta potential measurements in order to evaluate their properties in terms of their surface charge and point of zero charge (pzc) values. It was found from XRD data that these clays were almost pure and their electrokinetic potential should therefore be representative of their colloidal behavior. All three clay minerals were negatively charged over the range from pH 2.5 to 11. Chlorite and illite have pzc at pH 3 and pH 2.5, respectively, whereas kaolinite has no pzc. The effect of these clays in Zonguldak coal, wastes, and black waters on coal flotation was studied by floating artificial mixtures of Zonguldak clean coal (4.5% ash) and individual clay. The flotation tests on coal/individual clay revealed that each clay influences coal flotation differently according to its type and amount. Illite had the worst effect on coal floated, followed by chlorite and kaolinite. The loss of yield in coal was found to be 18% for kaolinite, 20% for chlorite, and 28% for illite, indicating the worst effect of illite and least for kaolinite during coal flotation.

  4. A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection.

    PubMed

    de Aquino, Emerson Vidal; Rohwedder, Jarbas José Rodrigues; Pasquini, Celio

    2006-11-01

    Monosegmented flow analysis (MSFA) has been used as a flow-batch system to produce a simple, robust, and mechanized titrator that enables true titrations to be performed without the use of standards. This paper also introduces the use of coulometry with monosegmented titration by proposing a versatile flow cell. Coulometric generation of the titrand is attractive for titrations performed in monosegmented systems, because the reagent can be added without increasing the volume of sample injected. Also, biamperomeric and potentiometric detection of titration end-points can increase the versatility of the monosegmented titrator. The cell integrates coulometric generation of the titrand with detection of end-point by potentiometry or biamperometry. The resulting titrator is a flow-batch system in which the liquid monosegment, constrained by the interfaces of the gaseous carrier stream, plays the role of a sample of known volume to be titrated. The system has been used for determination of ascorbic acid, by coulometric generation of I2 with biamperometric detection, and for determination of Fe(II), by coulometric generation of Ce(IV) with potentiometric detection of the end-point, both in feed supplements.

  5. pH Effects on solubility, zeta potential, and correlation between antibacterial activity and molecular weight of chitosan.

    PubMed

    Chang, Shun-Hsien; Lin, Hong-Ting Victor; Wu, Guan-James; Tsai, Guo Jane

    2015-12-10

    Six chitosans with molecular weights (MWs) of 300, 156, 72.1, 29.2, 7.1, and 3.3 kDa were prepared by cellulase degradation of chitosan (300 kDa) and ultrafiltration techniques. We examined the correlation between activity against Escherichia coli and Staphylococcus aureus and chitosan MW, and provided the underlying explanation. In acidic pH conditions, the chitosan activity increased with increasing MW, irrespective of the temperature and bacteria tested. However, at neutral pH, chitosan activity increased as the MW decreased, and little activity was observed for chitosans with MW >29.2 kDa. At pH 5.0 and 6.0, chitosans exhibited good water solubility and zeta potential (ZP) decreased with the MW, whereas the solubility and ZP of the chitosans decreased with increasing MW at pH 7.0. Particularly, low solubility and negative ZP values were determined for chitosans with MW >29.2 kDa, which may explain the loss of their antibacterial activity at pH 7.0. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Chromospheric Structure and Wind Acceleration in Zeta Aur Stars

    NASA Technical Reports Server (NTRS)

    Bennett, Philip D.

    2001-01-01

    This NASA grant supported an analysis of the variability of the wind of the supergiant primary star (K4 Ib) in the eclipsing binary Zeta Aurigae (Zeta Aur). In the ultraviolet, the main-sequence companion star (B5 V) dominates the observed flux, and therefore serves as a convenient probe of the cool supergiant's wind. This study utilized the extensive set of (100+) ultraviolet spectroscopic observations obtained with the International Ultraviolet Explorer (IUE) satellite over its operational lifetime of 1978-1995. Although the resolution of IUE is limited (about 25 km/s), it is adequate to resolve variability in the wind features in Zeta Aur's ultraviolet spectrum, which are blueshifted 70 km/s from line center. Our analysis used the tau-v technique of Cardelli and Savage, which makes full use of the available line profile information. We find that the wind column densities vary by up to an order of magnitude over time. These results are being written up for submission to the Astrophysical Journal as the third paper of a series on the chromosphere and wind of Zeta Aurigae. The first two papers report on the construction of mean chromosphere and wind models respectively, based on HST/GHRS observations and funded by STScI. The third paper - this research - reports on variability of the Zeta Aur wind as determined from our analysis of the long IUE time series. This paper will be completed within the next three months; the delay in publication was to allow the completion of Papers 1 and 2, which logically precede the present work. Therefore, an additional no-cost extension was requested in order to ensure budgeted funds remain available for publication of this work. Unfortunately, this request was denied, and so I am forced to write this final report before publication of Paper 3. Regardless, this paper will be submitted for publication within the next three months.

  7. Group entropies, correlation laws, and zeta functions.

    PubMed

    Tempesta, Piergiulio

    2011-08-01

    The notion of group entropy is proposed. It enables the unification and generaliztion of many different definitions of entropy known in the literature, such as those of Boltzmann-Gibbs, Tsallis, Abe, and Kaniadakis. Other entropic functionals are introduced, related to nontrivial correlation laws characterizing universality classes of systems out of equilibrium when the dynamics is weakly chaotic. The associated thermostatistics are discussed. The mathematical structure underlying our construction is that of formal group theory, which provides the general structure of the correlations among particles and dictates the associated entropic functionals. As an example of application, the role of group entropies in information theory is illustrated and generalizations of the Kullback-Leibler divergence are proposed. A new connection between statistical mechanics and zeta functions is established. In particular, Tsallis entropy is related to the classical Riemann zeta function.

  8. Natural monocrystalline pyrite as a sensor in non-aqueous solution Part I: Potentiometric titration of weak acids in, N,N-dimethylformamide, methylpyrrolidone and pyridine.

    PubMed

    Mihajlović, Lj V; Mihajlović, R P; Antonijević, M M; Vukanović, B V

    2004-11-15

    The possibility of applying natural monocrystaline pyrite as a sensor for the potentiometric titration of weak acids in N,N-dimethylformamide, methylpyrrolidone and pyridine was investigated. The potential of this electrode in N,N-dimethylformamide, methylpyrrolidone and pyridine exhibits a sub-Nernst dependence. In N,N-dimethylformamide the slope (mV/pH) is 39.0 and in methylpyrrolidone it is 45.0. The potential jumps at the titration end-point obtained in the titration of weak acids are higher than those obtained by the application of a glass electrode as the indicator electrode The potential in the course of the titration and at the titration end-point (TEP) are rapidly established. Sodium methylate, potassium hydroxide and tetrabutylammonium hydroxide (TBAH) proved to be very suitable titrating agents for these titrations. The results obtained in the determination of the investigated weak acids deviate by 0.1-0.35% with respect to those obtained by using a glass electrode as the indicator electrode.

  9. Rotationally excited HD toward Zeta Ophiuchi

    NASA Technical Reports Server (NTRS)

    Wright, E. L.; Morton, D. C.

    1979-01-01

    Copernicus satellite measurements of HD in J-double prime = 1 and J-double prime = 0 toward Zeta Oph are reported. The ratio of the number densities of HD in the J = 0 and J = 1 states is determined to be 0.15 + or - 0.02 at the 1-sigma level. A value of approximately 24 x 10 to the -17th erg/cu cm per A at 1000 A is obtained for the UV energy density at the Zeta Oph cloud, and the mechanisms for excitation of HD are examined. A tight upper limit is derived for the abundance of HCl, which has been predicted to be present due to the interaction of ionized chlorine with neutral hydrogen. A calculation is performed which indicates that the cloud is 28 pc from the star. It is shown that the two-component cloud model of Black and Dalgarno (1977) with densities of 500 and 2500 H nuclei per cu cm for the outer regions and core, respectively, is in excellent agreement with the observations.

  10. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    PubMed

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P < 0.001). After using a ΔP of 3 cmH(2)O for the cutoff value (ΔP was defined as the difference of automatic titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P < 0.001). However, there were no differences for the pressure of manual titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the

  11. Potential benefits of slow titration of paroxetine treatment in an elderly population: eight-week results from a naturalistic setting.

    PubMed

    Gibiino, Sara; Mori, Elisa; De Ronchi, Diana; Serretti, Alessandro

    2013-08-01

    Late-life depression, often in association with anxiety, affects approximately 15% of individuals older than 65 years. Selective serotonin reuptake inhibitors are the first-line treatment but could be responsible of an early exacerbation of anxiety, possibly reduced by a very gradual titration of drugs. The main aim of this study is to compare gradual and rapid (standard) titration of paroxetine in an elderly population. In a naturalistic setting, 50 elderly (≥60 years old) outpatients with unipolar mood disorder or anxiety disorder were naturalistically assigned to abrupt initiation of 10 mg of paroxetine or to a gradual increase with 2.5 mg on alternate days up to 10 mg in 7 days. Then dosage could be maintained at 10 mg or increased according to clinical response. Primary outcome was efficacy as assessed by the Hamilton Depression Rating Scale (HAM-D) 21, HAM-D symptom subscales (core, psychic anxiety, somatic anxiety cluster), and Hamilton Anxiety Rating Scale changes. Secondary outcome was evaluation of overall dropouts at eighth week and evaluation of most common adverse effects through the global judgment of the Dosage Record and Treatment Emergent Symptom Scale. All data were recorded weekly for the first 8 weeks of treatment (with 1 more evaluation after 3 days from the baseline). Samples were comparable at baseline, with patients in gradual titration showing a higher level of psychic anxiety. During the first 3 days of treatment, a significant worsening in psychic anxiety was observed in patients treated abruptly with 10 mg of paroxetine (difference in HAM-D psychic anxiety subscale from baseline: 110.61% vs 89.38% with rapid and slow titration, respectively; t test P = 0.03). Overall, a significantly greater improvement in depressive and anxious symptoms favored gradual titration (HAM-D core cluster and HAM-D psychic anxiety cluster, respectively, P = 0.014 and P < 0.001, also when controlling for confounders). At the eighth week, significant higher

  12. Dynamic interaction between 14-3-3zeta and bax during TNF-α-induced apoptosis in living cells

    NASA Astrophysics Data System (ADS)

    Gao, Xuejuan; Xing, Da; Chen, Tongsheng

    2006-09-01

    Bax, a proapoptotic member of the Bcl-2 family, localizes largely in the cytoplasm but redistributes to mitochondria and undergoes oligomerization to induce the release of apoptogenic factors such as cytochrome c in response to apoptotic stimuli. Cytoplasmic protein 14-3-3zeta binds to Bax and, upon apoptotic stimulation, releases Bax by a caspase-independent mechanism. However, the direct interaction of the cytoplasmic 14-3-3zeta and Bax in living cells has not been observed. In present study, to monitor the dynamic interaction between 14-3-3zeta and Bax in living cells in real time during apoptosis induced by tumor necrosis factor (TNF-α), DsRed-14-3-3zeta plasmid is constructed. By cotransfecting DsRed- 14-3-3zeta and GFP-Bax plasmids into human lung adenocarcinoma cells (ASTC-a-1), we observe the dynamic interaction between Bax and 14-3-3zeta using fluorescence resonance energy transfer (FRET) technique on laser scanning confocal microscope. The results show that 14-3-3zeta remains in the cytoplasm but GFP-Bax translocates to mitochondria completely after TNF-α stimulation. These results reveal that 14-3-3zeta binds directly to Bax in healthy cells, and that 14-3-3zeta negatively regulates Bax translocation to mitochondria during TNF-α-induced apoptosis.

  13. Three proposed B-associations in the vicinity of zeta puppis

    NASA Technical Reports Server (NTRS)

    Upton, E. K. L.

    1971-01-01

    There appear to be three loose B associations in the general vicinity of zeta Puppis, all at distances of approximately 300 to 400 parsecs from the sun. Their diameters, perpendicular to the line of sight, are 20 to 50 parsecs, and their separations are of similar size. All three are situated in bright areas of the Gum nebula. The proposed associations A and C lie in the two brightest parts of the nebula. The three associations are not all of the same age. Association C is about 50 million years old, whereas A and B are decidedly younger. The ages of A and B cannot be determined from the present data, as their color-magnitude diagrams show no clear turnoff from the main sequence. Association A may be young enough to qualify as the birthplace of zeta Puppis. There is no other identifiable association in which zeta Puppis can have originated, unless its age is substantially greater than the 3 million years assumed.

  14. Can Eccentric Debris Disks Be Long-lived? A First Numerical Investigation and Application to Zeta(exp 2) Reticuli

    NASA Technical Reports Server (NTRS)

    Faramaz, V.; Beust, H.; Thebault, P.; Augereau, J.-C.; Bonsor, A.; delBurgo, C.; Ertel, S.; Marshall, J. P.; Milli, J.; Montesinos, B.; hide

    2014-01-01

    Context. Imaging of debris disks has found evidence for both eccentric and offset disks. One hypothesis is that they provide evidence for massive perturbers, for example, planets or binary companions, which sculpt the observed structures. One such disk was recently observed in the far-IR by the Herschel Space Observatory around Zeta2 Reticuli. In contrast with previously reported systems, the disk is significantly eccentric, and the system is several Gyr old. Aims. We aim to investigate the long-term evolution of eccentric structures in debris disks caused by a perturber on an eccentric orbit around the star. We hypothesise that the observed eccentric disk around Zeta2 Reticuli might be evidence of such a scenario. If so, we are able to constrain the mass and orbit of a potential perturber, either a giant planet or a binary companion. Methods. Analytical techniques were used to predict the effects of a perturber on a debris disk. Numerical N-body simulations were used to verify these results and further investigate the observable structures that may be produced by eccentric perturbers. The long-term evolution of the disk geometry was examined, with particular application to the Zeta2 Reticuli system. In addition, synthetic images of the disk were produced for direct comparison with Herschel observations. Results. We show that an eccentric companion can produce both the observed offsets and eccentric disks. These effects are not immediate, and we characterise the timescale required for the disk to develop to an eccentric state (and any spirals to vanish). For Zeta2 Reticuli, we derive limits on the mass and orbit of the companion required to produce the observations. Synthetic images show that the pattern observed around Zeta2 Reticuli can be produced by an eccentric disk seen close to edge-on, and allow us to bring additional constraints on the disk parameters of our model (disk flux and extent). Conclusions. We conclude that eccentric planets or stellar companions

  15. Elucidation of the mechanisms of action of Bacteriophage K/nano-emulsion formulations against S. aureus via measurement of particle size and zeta potential.

    PubMed

    Esteban, Patricia Perez; Jenkins, A Toby A; Arnot, Tom C

    2016-03-01

    In earlier work we have demonstrated the effect that nano-emulsions have on bacterial growth, and most importantly the enhanced bacteriophage infectivity against Staphylococcus aureus in planktonic culture when phage are carried in nano-emulsions. However, the mechanisms of enhancement of the bacteriophage killing effect are not specifically understood. This work focuses on the investigation of the possible interactions between emulsion droplets and bacterial cells, between emulsion droplets and bacteriophages, and finally interactions between all three components: nano-emulsion droplets, bacteria, and bacteriophages. The first approach consists of simple calculations to determine the spatial distribution of the components, based on measurements of particle size. It was found that nano-emulsion droplets are much more numerous than bacteria or bacteriophage, and due to their size and surface area they must be covering the surface of both cells and bacteriophage particles. Stabilisation of bacteriophages due to electrostatic forces and interaction with nano-emulsion droplets is suspected, since bacteriophages may be protected against inactivation due to 'charge shielding'. Zeta potential was measured for the individual components in the system, and for all of them combined. It was concluded that the presence of nano-emulsions could be reducing electrostatic repulsion between bacterial cells and bacteriophage, both of which are very negatively 'charged'. Moreover, nano-emulsions lead to more favourable interaction between bacteriophages and bacteria, enhancing the anti-microbial or killing effect. These findings are relevant since the physicochemical properties of nano-emulsions (i.e. particle size distribution and zeta potential) are key in determining the efficacy of the formulation against infection in the context of responsive burn wound dressings-which is the main target for this work. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Electroosmotic flow in a rectangular channel with variable wall zeta-potential: comparison of numerical simulation with asymptotic theory.

    PubMed

    Datta, Subhra; Ghosal, Sandip; Patankar, Neelesh A

    2006-02-01

    Electroosmotic flow in a straight micro-channel of rectangular cross-section is computed numerically for several situations where the wall zeta-potential is not constant but has a specified spatial variation. The results of the computation are compared with an earlier published asymptotic theory based on the lubrication approximation: the assumption that any axial variations take place on a long length scale compared to a characteristic channel width. The computational results are found to be in excellent agreement with the theory even when the scale of axial variations is comparable to the channel width. In the opposite limit when the wavelength of fluctuations is much shorter than the channel width, the lubrication theory fails to describe the solution either qualitatively or quantitatively. In this short wave limit the solution is well described by Ajdari's theory for electroosmotic flow between infinite parallel plates (Ajdari, A., Phys. Rev. E 1996, 53, 4996-5005.) The infinitely thin electric double layer limit is assumed in the theory as well as in the simulation.

  17. Symmetry Properties of Potentiometric Titration Curves.

    ERIC Educational Resources Information Center

    Macca, Carlo; Bombi, G. Giorgio

    1983-01-01

    Demonstrates how the symmetry properties of titration curves can be efficiently and rigorously treated by means of a simple method, assisted by the use of logarithmic diagrams. Discusses the symmetry properties of several typical titration curves, comparing the graphical approach and an explicit mathematical treatment. (Author/JM)

  18. A Tabular Approach to Titration Calculations

    ERIC Educational Resources Information Center

    Lim, Kieran F.

    2012-01-01

    Titrations are common laboratory exercises in high school and university chemistry courses, because they are easy, relatively inexpensive, and they illustrate a number of fundamental chemical principles. While students have little difficulty with calculations involving a single titration step, there is a significant leap in conceptual difficulty…

  19. Observations of H II regions around Zeta OPH and other O-B stars

    NASA Astrophysics Data System (ADS)

    Shestakova, L. I.; Kutirev, A. S.; Ataev, A. Sh.

    1988-01-01

    A Fabry-Perot spectrometer was used to measure the emission intensities in H-beta near Zeta Oph, Alpha Vir, Alpha Cam, and HD 188209. The spectrometer sensitivity is 0.2 rayleighs, the intensity measurement accuracy is 20 percent. Ionization zone boundaries are determined for Zeta Oph and Alpha Vir; the angular diameters of both regions are about 15 deg. The contour of the H II region near Zeta Oph on the level of the double background in the southwest does not close; instead, it expands again and incorporates the region associated with the B-association II Sco.

  20. Rapid Clozapine Titration in Patients with Treatment Refractory Schizophrenia.

    PubMed

    Poyraz, Cana Aksoy; Özdemir, Armağan; Sağlam, Nazife Gamze Usta; Turan, Şenol; Poyraz, Burç Çağrı; Tomruk, Nesrin; Duran, Alaattin

    2016-06-01

    The aim of this study is to evaluate the safety and effectiveness of rapid clozapine titration in patients with schizophrenia in hospital settings. We conducted a retrospective two-center cohort study to compare the safety and effectiveness of clozapine with different titration rates in treatment-refractory patients with schizophrenia. In the first center, clozapine was started at 25-50 mg followed by 50-100 mg as needed every 6 h on day 1, followed by increases of 50-100 mg/day. In the second center, titration was slower; clozapine initiated with 12.5-50 mg on day 1 followed by increases of 25-50 mg/day. The number of days between starting of clozapine until discharge was shorter in the rapid titration group (22.4 ± 8.72 vs 27.0 ± 10.5, p = 0.1). Number of days of total hospital stay were significantly shorter in the rapid titration group (29.6 ± 10.6 vs 41.2 ± 14.8, p = 0.002). Hypotension was more common in the rapid titration group and one patient had suspected myocarditis. Rapid clozapine titration appeared safe and effective. The length of stay following initiation of clozapine was shorter in the rapid-titration group, although this was not statistically significant. However starting clozapine earlier together with rapid titration has significantly shortened the length of hospital stay in patients with treatment refractory schizophrenia.

  1. Up-titration of allopurinol in patients with gout.

    PubMed

    Jennings, Claudine G; Mackenzie, Isla S; Flynn, Rob; Ford, Ian; Nuki, George; De Caterina, Raffaele; Riches, Philip L; Ralston, Stuart H; MacDonald, Thomas M

    2014-08-01

    European League against Rheumatism (EULAR) gout management guidelines recommend achieving a target urate level <6.0 mg/dL (<357 µmol/L). Allopurinol is the most widely used urate-lowering therapy; however, many gout patients who are prescribed allopurinol do not have urate levels optimally controlled. The objective of this analysis was to review the efficacy and tolerability of allopurinol up-titration in achieving the EULAR target levels. The Febuxostat versus Allopurinol Streamlined Trial (FAST) is an ongoing multi-centre study comparing the cardiovascular safety of febuxostat and allopurinol (target recruitment: 5706 patients). Recruited patients were already taking allopurinol and the protocol required up-titration of daily allopurinol dose, in 100 mg increments, to achieve the EULAR urate target level prior to randomisation. We reviewed pre-randomisation data from the first 400 recruited and subsequently randomised FAST patients. Of 400 patients, 144 (36%) had urate levels ≥357 µmol/L at screening and required allopurinol up-titration. Higher urate levels were significantly associated with lower allopurinol dose, male sex, increased BMI, increased alcohol intake and diuretic use. Mean fall in urate levels after a single 100-mg dose increase was 71 µmol/L. The number of up-titrations required ranged from one to five (median = 1) with 65% of patients controlled after one 100-mg up-titration. Overall, 97% of up-titrated patients achieved target urate levels with median final allopurinol dose of 300 mg daily. Side effects and complications of up-titration were minimal. Overall, 36% of FAST patients were not at target urate levels and required up-titration. Allopurinol up-titration was effective in achieving urate target levels and was generally well tolerated by patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. A stable and convenient protein electrophoresis titration device with bubble removing system.

    PubMed

    Zhang, Qiang; Fan, Liu-Yin; Li, Wen-Lin; Cong, Feng-Song; Zhong, Ran; Chen, Jing-Jing; He, Yu-Chen; Xiao, Hua; Cao, Cheng-Xi

    2017-07-01

    Moving reaction boundary titration (MRBT) has a potential application to immunoassay and protein content analysis with high selectivity. However, air bubbles often impair the accuracy of MRBT, and the leakage of electrolyte greatly decreases the safety and convenience of electrophoretic titration. Addressing these two issues a reliable MRBT device with modified electrolyte chamber of protein titration was designed. Multiphysics computer simulation was conducted for optimization according to two-phase flow. The single chamber was made of two perpendicular cylinders with different diameters. After placing electrophoretic tube, the resident air in the junction next to the gel could be eliminated by a simple fast electrolyte flow. Removing the electrophoretic tube automatically prevented electrolyte leakage at the junction due to the gravity-induced negative pressure within the chamber. Moreover, the numerical simulation and experiments showed that the improved MRBT device has following advantages: (i) easy and rapid setup of electrophoretic tube within 20 s; (ii) simple and quick bubble dissipates from the chamber of titration within 2 s; (iii) no electrolyte leakage from the two chambers: and (iv) accurate protein titration and safe instrumental operation. The developed technique and apparatus greatly improves the performance of the previous MRBT device, and providing a new route toward practical application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Kinetics of bacterial potentiometric titrations: the effect of equilibration time on buffering capacity of Pantoea agglomerans suspensions.

    PubMed

    Kapetas, Leon; Ngwenya, Bryne T; Macdonald, Alan M; Elphick, Stephen C

    2011-07-15

    Several recent studies have made use of continuous acid-base titration data to describe the surface chemistry of bacterial cells as a basis for accurately modelling metal adsorption to bacteria and other biomaterials of potential industrial importance. These studies do not share a common protocol; rather they titrate in different pH ranges and they use different stability criteria to define equilibration time during titration. In the present study we investigate the kinetics of bacterial titrations and test the effect they have on the derivation of functional group concentrations and acidity constants. We titrated suspensions of Pantoea agglomerans by varying the equilibration time between successive titrant additions until stability of 0.1 or 0.001 mV s(-1) was attained. We show that under longer equilibration times, titration results are less reproducible and suspensions exhibit marginally higher buffering. Fluorescence images suggest that cell lysis is not responsible for these effects. Rather, high DOC values and titration reversibility hysterisis after long equilibration times suggest that variability in buffering is due to the presence of bacterial exudates, as demonstrated by titrating supernatants separated from suspensions of different equilibration times. It is recommended that an optimal equilibration time is always determined with variable stability control and preliminary reversibility titration experiments. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Relating zeta functions of discrete and quantum graphs

    NASA Astrophysics Data System (ADS)

    Harrison, Jonathan; Weyand, Tracy

    2018-02-01

    We write the spectral zeta function of the Laplace operator on an equilateral metric graph in terms of the spectral zeta function of the normalized Laplace operator on the corresponding discrete graph. To do this, we apply a relation between the spectrum of the Laplacian on a discrete graph and that of the Laplacian on an equilateral metric graph. As a by-product, we determine how the multiplicity of eigenvalues of the quantum graph, that are also in the spectrum of the graph with Dirichlet conditions at the vertices, depends on the graph geometry. Finally we apply the result to calculate the vacuum energy and spectral determinant of a complete bipartite graph and compare our results with those for a star graph, a graph in which all vertices are connected to a central vertex by a single edge.

  5. Potentiometric Titrations for Measuring the Capacitance of Colloidal Photodoped ZnO Nanocrystals.

    PubMed

    Brozek, Carl K; Hartstein, Kimberly H; Gamelin, Daniel R

    2016-08-24

    Colloidal semiconductor nanocrystals offer a unique opportunity to bridge molecular and bulk semiconductor redox phenomena. Here, potentiometric titration is demonstrated as a method for quantifying the Fermi levels and charging potentials of free-standing colloidal n-type ZnO nanocrystals possessing between 0 and 20 conduction-band electrons per nanocrystal, corresponding to carrier densities between 0 and 1.2 × 10(20) cm(-3). Potentiometric titration of colloidal semiconductor nanocrystals has not been described previously, and little precedent exists for analogous potentiometric titration of any soluble reductants involving so many electrons. Linear changes in Fermi level vs charge-carrier density are observed for each ensemble of nanocrystals, with slopes that depend on the nanocrystal size. Analysis indicates that the ensemble nanocrystal capacitance is governed by classical surface electrical double layers, showing no evidence of quantum contributions. Systematic shifts in the Fermi level are also observed with specific changes in the identity of the charge-compensating countercation. As a simple and contactless alternative to more common thin-film-based voltammetric techniques, potentiometric titration offers a powerful new approach for quantifying the redox properties of colloidal semiconductor nanocrystals.

  6. Zeta Pegasi: An SPB Variable Star

    NASA Technical Reports Server (NTRS)

    Goebel, John H.

    2007-01-01

    Broadband photometric observations of the bright star Zeta Pegasi are presented that display brightness variability of 488.2 +/- 6.6 micromag (ppm) range with a period of 22.952 +/- 0.804 hr (f approx. equals 1.04566 c/d). The variation is monosinusoidal, so the star is recommended for membership in the class of small-amplitude Slowly Pulsating B-Stars (SPB) variables oscillating in a non-radial g-mode.

  7. Linear Titration Curves of Acids and Bases.

    PubMed

    Joseph, N R

    1959-05-29

    The Henderson-Hasselbalch equation, by a simple transformation, becomes pH - pK = pA - pB, where pA and pB are the negative logarithms of acid and base concentrations. Sigmoid titration curves then reduce to straight lines; titration curves of polyelectrolytes, to families of straight lines. The method is applied to the titration of the dipeptide glycyl aminotricarballylic acid, with four titrable groups. Results are expressed as Cartesian and d'Ocagne nomograms. The latter is of a general form applicable to polyelectrolytes of any degree of complexity.

  8. Potentiometric titration and equivalent weight of humic acid

    USGS Publications Warehouse

    Pommer, A.M.; Breger, I.A.

    1960-01-01

    The "acid nature" of humic acid has been controversial for many years. Some investigators claim that humic acid is a true weak acid, while others feel that its behaviour during potentiometric titration can be accounted for by colloidal adsorption of hydrogen ions. The acid character of humic acid has been reinvestigated using newly-derived relationships for the titration of weak acids with strong base. Re-interpreting the potentiometric titration data published by Thiele and Kettner in 1953, it was found that Merck humic acid behaves as a weak polyelectrolytic acid having an equivalent weight of 150, a pKa of 6.8 to 7.0, and a titration exponent of about 4.8. Interdretation of similar data pertaining to the titration of phenol-formaldehyde and pyrogallol-formaldehyde resins, considered to be analogs for humic acid by Thiele and Kettner, leads to the conclusion that it is not possible to differentiate between adsorption and acid-base reaction for these substances. ?? 1960.

  9. pH Static Titration: A Quasistatic Approach

    ERIC Educational Resources Information Center

    Michalowski, Tadeusz; Toporek, Marcin; Rymanowski, Maciej

    2007-01-01

    The pH-static titration is applicable to those systems where at least two types of reactions occur in comparable intensities. The commonalities in titrimetric procedure realized according to pH-static titration, irrespective of the kind of chemical processes occurring are discussed.

  10. Computational strategies for the Riemann zeta function

    NASA Astrophysics Data System (ADS)

    Borwein, Jonathan M.; Bradley, David M.; Crandall, Richard E.

    2000-09-01

    We provide a compendium of evaluation methods for the Riemann zeta function, presenting formulae ranging from historical attempts to recently found convergent series to curious oddities old and new. We concentrate primarily on practical computational issues, such issues depending on the domain of the argument, the desired speed of computation, and the incidence of what we call "value recycling".

  11. Humic substance charge determination by titration with a flexible cationic polyelectrolyte

    NASA Astrophysics Data System (ADS)

    Tan, Wen-Feng; Norde, Willem; Koopal, Luuk K.

    2011-10-01

    The anionic charge of humic substances (HS) plays a major role in the interaction of HS with other components. Therefore, the potential of the polyelectrolyte titration technique to obtain the charge density of HS in simple 1-1 electrolyte solutions has been investigated. Titrations are carried out with an automatic titrator combined with the "Mütek particle charge detector" which allows determination of the Mütek potential and the pH as a function of the added amount of titrant which is a solution of poly-diallyldimethylammonium chloride (polyDADMAC), a cationic strong polyelectrolyte. When the Mütek potential reverses its sign the iso-electric point (IEP) of the polyDADMAC-HS complex is reached. The polyDADMAC/HS mass ratio at the IEP gives information on the HS charge density and from the pH changes in solution an estimate of the charge regulation in the HS-polyDADMAC complex can be obtained. In general, for polyDADMAC-HS complexes an increase in the dissociation of the acid groups of HS is found (charge regulation). The charge regulation decreases with increasing concentration of 1-1 background electrolyte. Cation incorporation can be neglected at 1-1 electrolyte concentrations ⩽ 1 mmol L -1 and a 1-1 stoichiometry exists between the polyDADMAC and HS charge. However, at these low salt concentrations the charge regulation is substantial. A detailed analysis of purified Aldrich humic acid (PAHA) at pH 5 and a range of KCl concentrations reveals that the anionic charge of PAHA in the complex increases at 5 mmol L -1 KCl by 30% and at 150 mmol L -1 KCl by 12%. On the other hand, increasing amounts of K + become incorporated in the complex: at 5 mmol L -1 KCl 5% and at 150 mmol L -1 KCl 24% of the PAHA charge is balanced by K +. By comparing at pH 5 the mass ratios polyDADMAC/PAHA in the complex at the IEP with the theoretical mass ratios of polyDADMAC/PAHA required to neutralize PAHA in the absence of charge regulation and K + incorporation, it is found that

  12. Controlled clustering of carboxylated SPIONs through polyethylenimine

    NASA Astrophysics Data System (ADS)

    Nesztor, Dániel; Bali, Krisztina; Tóth, Ildikó Y.; Szekeres, Márta; Tombácz, Etelka

    2015-04-01

    Clusters of magnetite nanoparticles (MNPs) were synthesized using poly(acrylic acid-co-maleic acid) coated MNPs (PAM@MNP) and branched polyethylenimine (PEI). Materials were characterized by potentiometric titration, zeta potential and dynamic light scattering (DLS) measurements. PEI and PAM@MNP are oppositely charged as characterized by zeta potential measurements (+8, -34 mV respectively) and titration (10.30 mmol -NH3+/g PEI; 0.175 mmol -COO-/g PAM@MNP) at pH 6.5±0.2; therefore magnetic clusters are formed by electrostatic adhesion. Two different preparation methods and the effect of PEI and electrolyte (NaCl) concentration on the cluster formation was studied. Choosing an optimal concentration of PEI (charge ratio of PEI to PAM@MNP: 0.17) and electrolyte (10 mM), a concentrated (10 g MNP/L) product containing PEI-PAM@MNP nanoclusters with size of 165±10 nm was prepared. Its specific absorption rate (SAR) measured in AC magnetic field (110 kHz, 25 mT) is 12 W/g Fe. The clustered product is expected to have enhanced contrast efficiency in MRI.

  13. Thermometric titration in investigation of the formation of polyanions of molybdenum(VI), tungsten(VI), vanadium(V), and chromium (VI)-I: comparison of thermometric and potentiometric titration curves.

    PubMed

    Kiba, N; Takeuchi, T

    1973-09-01

    A new twin-cell thermometric titrator has been devised and used for thermometric titration of solutions of sodium molybdate, sodium tungstate, sodium orthovanadate, ammonium metavanadate, and potassium chromate with perchloric acid. The thermometric titration curves were compared with corresponding pH-titration curves for elucidation of the reactions occurring in the titrations. Thermometric titrimetric methods have been developed for the determination of tungsten, vanadium and chromium.

  14. The Structural Evolution of Milky-Way-Like Star-Forming Galaxies zeta is approximately 1.3

    NASA Technical Reports Server (NTRS)

    Patel, Shannon G.; Fumagalli, Mattia; Franx, Marun; VanDokkum, Pieter G.; VanDerWel, Arjen; Leja, Joel; Labbe, Ivo; Brammr, Gabriel; Whitaker, Katherine E.; Skelton, Rosalind E.; hide

    2013-01-01

    We follow the structural evolution of star-forming galaxies (SFGs) like the Milky Way by selecting progenitors to zeta is approx. 1.3 based on the stellar mass growth inferred from the evolution of the star-forming sequence. We select our sample from the 3D-HT survey, which utilizes spectroscopy from the HST-WFC3 G141 near-IR grism and enables precise redshift measurements for our sample of SFGs. Structural properties are obtained from Sersic profile fits to CANDELS WFC3 imaging. The progenitors of zeta = 0 SFGs with stellar mass M = 10(exp 10.5) solar mass are typically half as massive at zeta is approx. 1. This late-time stellar mass grow is consistent with recent studies that employ abundance matching techniques. The descendant SFGs at zeta is approx. 0 have grown in half-light radius by a factor of approx. 1.4 zeta is approx. 1. The half-light radius grows with stellar mass as r(sub e) alpha stellar mass(exp 0.29). While most of the stellar mass is clearly assembling at large radii, the mass surface density profiles reveal ongoing mass growth also in the central regions where bulges and pseudobulges are common features in present day late-type galaxies. Some portion of this growth in the central regions is due to star formation as recent observations of H(a) maps for SFGs at zeta approx. are found to be extended but centrally peaked. Connecting our lookback study with galactic archeology, we find the stellar mass surface density at R - 8 kkpc to have increased by a factor of approx. 2 since zeta is approx. 1, in good agreement with measurements derived for the solar neighborhood of the Milky Way.

  15. Charge characteristics of humic and fulvic acids: comparative analysis by colloid titration and potentiometric titration with continuous pK-distribution function model.

    PubMed

    Bratskaya, S; Golikov, A; Lutsenko, T; Nesterova, O; Dudarchik, V

    2008-09-01

    Charge characteristics of humic and fulvic acids of a different origin (inshore soils, peat, marine sediments, and soil (lysimetric) waters) were evaluated by means of two alternative methods - colloid titration and potentiometric titration. In order to elucidate possible limitations of the colloid titration as an express method of analysis of low content of humic substances we monitored changes in acid-base properties and charge densities of humic substances with soil depth, fractionation, and origin. We have shown that both factors - strength of acidic groups and molecular weight distribution in humic and fulvic acids - can affect the reliability of colloid titration. Due to deviations from 1:1 stoichiometry in interactions of humic substances with polymeric cationic titrant, the colloid titration can underestimate total acidity (charge density) of humic substances with domination of weak acidic functional groups (pK>6) and high content of the fractions with molecular weight below 1kDa.

  16. Students' integration of multiple representations in a titration experiment

    NASA Astrophysics Data System (ADS)

    Kunze, Nicole M.

    A complete understanding of a chemical concept is dependent upon a student's ability to understand the microscopic or particulate nature of the phenomenon and integrate the microscopic, symbolic, and macroscopic representations of the phenomenon. Acid-base chemistry is a general chemistry topic requiring students to understand the topics of chemical reactions, solutions, and equilibrium presented earlier in the course. In this study, twenty-five student volunteers from a second semester general chemistry course completed two interviews. The first interview was completed prior to any classroom instruction on acids and bases. The second interview took place after classroom instruction, a prelab activity consisting of a titration calculation worksheet, a titration computer simulation, or a microscopic level animation of a titration, and two microcomputer-based laboratory (MBL) titration experiments. During the interviews, participants were asked to define and describe acid-base concepts and in the second interview they also drew the microscopic representations of four stages in an acid-base titration. An analysis of the data showed that participants had integrated the three representations of an acid-base titration to varying degrees. While some participants showed complete understanding of acids, bases, titrations, and solution chemistry, other participants showed several alternative conceptions concerning strong acid and base dissociation, the formation of titration products, and the dissociation of soluble salts. Before instruction, participants' definitions of acid, base, and pH were brief and consisted of descriptive terms. After instruction, the definitions were more scientific and reflected the definitions presented during classroom instruction.

  17. Implementation of a pharmacist-managed heart failure medication titration clinic.

    PubMed

    Martinez, Amanda S; Saef, Jerold; Paszczuk, Anna; Bhatt-Chugani, Hetal

    2013-06-15

    The development, implementation, and initial results of a pharmacist-managed heart failure (HF) medication titration clinic are described. In a quality-improvement initiative at a Veterans Affairs health care system, clinical pharmacists were incorporated into the hospital system's interprofessional outpatient HF clinic. In addition, a separate pharmacist-managed HF medication titration clinic was established, in which pharmacists were granted an advanced scope of practice and prescribing privileges, enabling them to initiate and adjust medication dosages under specific protocols jointly established by cardiology and pharmacy staff. Pharmacists involved in the titration clinic tracked patients' daily body weight, vital signs, and volume status using telephone-monitoring technology and via patient interviews. A retrospective chart review comparing achievement of target doses of angiotensin-converting enzyme inhibitor (ACEI), angiotensin-receptor blocker (ARB), and β-blocker therapies in a group of patients (n = 28) whose dosage titrations were carried out by nurses or physicians prior to implementation of the pharmacist-managed HF medication titration clinic and a group of patients (n = 27) enrolled in the medication titration clinic during its first six months of operation indicated that target ACEI and ARB doses were achieved in a significantly higher percentage of pharmacist-managed titration clinic enrollees (52.9% versus 31%, p = 0.007). Patients enrolled in the pharmacist-managed HF medication titration clinic also had a significantly higher rate of attainment of optimal β-blocker doses (49% versus 24.7%, p = 0.012). Implementation of a pharmacist-managed HF medication titration clinic increased the percentage of patients achieving optimal ACEI, ARB, and β-blocker dosages.

  18. Computer controlled titration with piston burette or peristaltic pump - a comparison.

    PubMed

    Hoffmann, W

    1996-09-01

    The advantages and problems of the use of piston burettes and peristaltic pumps for dosage of titrant solutions in automatic titrations are shown. For comparison, only the dosing devices were exchanged and all other components and conditions remained unchanged. The results of continuous acid base titration show good agreement and comparable reproducibility. Potentiometric sensors (glass electrodes) with different equilibration behaviour influence the results. The capability of such electrodes was tested. Conductometric measurements allow a much faster detection because there is no equilibration of electrodes. Piston burettes should be used for titration with very high precision, titration with organic solvents and slow titrations. Peristaltic pumps seem to be more suitable for continuous titrations and long time operation without service.

  19. Titration in the treatment of the more troubled patient.

    PubMed

    Winer, J A; Ornstein, E D

    2001-01-01

    This article defines and discusses a modification of technique recommended by the authors in the psychoanalytic treatment of more troubled patients--a modification they call titration. Titration is defined as a conscious decision by the analyst to increase or decrease assistance (or gratification) gradually, in order to facilitate the analytic process. The authors emphasize the complexity of decisions in treatment by focusing on the decision-making processes that titration requires. Guidelines and a case vignette are presented. The authors conclude by considering some of the politics involved in the introduction of technique modifications, the salience of the titration concept, and directions for further exploration.

  20. Small-volume potentiometric titrations: EPR investigations of Fe-S cluster N2 in mitochondrial complex I.

    PubMed

    Wright, John J; Salvadori, Enrico; Bridges, Hannah R; Hirst, Judy; Roessler, Maxie M

    2016-09-01

    EPR-based potentiometric titrations are a well-established method for determining the reduction potentials of cofactors in large and complex proteins with at least one EPR-active state. However, such titrations require large amounts of protein. Here, we report a new method that requires an order of magnitude less protein than previously described methods, and that provides EPR samples suitable for measurements at both X- and Q-band microwave frequencies. We demonstrate our method by determining the reduction potential of the terminal [4Fe-4S] cluster (N2) in the intramolecular electron-transfer relay in mammalian respiratory complex I. The value determined by our method, E m7 =-158mV, is precise, reproducible, and consistent with previously reported values. Our small-volume potentiometric titration method will facilitate detailed investigations of EPR-active centres in non-abundant and refractory proteins that can only be prepared in small quantities. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Implementation of the Baldwin-Barth turbulence model into the ZETA code and its diagnosis. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Low, Scott L.

    1993-01-01

    The Baldwin-Barth turbulence model was implemented into Zeta, a time-accurate, zonal, integro-differential code for incompressible laminar and turbulent flows. The implementation procedure is patterned after the model subroutine in ARC2D. The results of ZETA with the Baldwin-Barth turbulence model were compared with experimental data, with ZETA using Baldwin-Lomax model, and with ARC2D using the Baldwin-Barth model. The Baldwin-Barth model subroutine was tested by inputting an ARC2D velocity solution of an NACA-0012 airfoil at R(sub e) = 3.9 x 10(exp 6) and alpha = 5 deg. The resultant turbulent viscosity and Reynolds stresses compared favorably with the original data. For the same grid having grid points inside the laminar sublayer, which is necessary due to the one-equation nature of the model, ZETA however predicts early separation. It was found that the current ZETA has problem with such a fine grid. Further work is in progress to solve this problem.

  2. Endpoint titration and immunotherapy.

    PubMed

    King, H C

    1985-11-01

    Inhalant allergy, or "atopy" as it is now termed, is the best understood form of allergy today. In some circles, it is the only recognized form of allergy. While an overall picture of its effects on the body and a reasonable approach to its treatment now exist, many problems remain to be solved and much improvement in its treatment will probably occur within the next several years. Many new approaches to treatment of aeroallergens are now available; however, all are compared with the skin test, which is and has been the baseline for testing and treatment. Endpoint titration provides a quantitative means for undertaking treatment of aeroallergen sensitivity. In no other way does it differ from the forms of skin testing that have been widely used for generations. The practitioners of endpoint titration feel that this difference is highly significant in simplifying, validating, and shortening the necessary period of therapy. While the concept of endpoint titration is not difficult, it is by definition a quantitative form of testing and requires a degree of expertise in performing it correctly. While a good understanding of the method may be gained from the literature, adequate hands-on experience should be obtained by any physician prior to instituting the technique as a treatment modality. Once mastered, it becomes a reliable baseline for all forms of inhalant allergy care.

  3. Scopolamine Effects Under a Titrating-Delayed-Nonmatching-to-Position Procedure

    ERIC Educational Resources Information Center

    Porritt, M.; Poling, A.

    2008-01-01

    In a study of working memory, the performance of rats under titrating-delayed-nonmatching- to-position (TDNMTP) procedures was examined. Overall accuracy and the number of trials completed were inversely related to titration value, whereas the highest delay attained was directly related to titration value. When given intraperitoneally,…

  4. Differential Binding Models for Direct and Reverse Isothermal Titration Calorimetry.

    PubMed

    Herrera, Isaac; Winnik, Mitchell A

    2016-03-10

    Isothermal titration calorimetry (ITC) is a technique to measure the stoichiometry and thermodynamics from binding experiments. Identifying an appropriate mathematical model to evaluate titration curves of receptors with multiple sites is challenging, particularly when the stoichiometry or binding mechanism is not available. In a recent theoretical study, we presented a differential binding model (DBM) to study calorimetry titrations independently of the interaction among the binding sites (Herrera, I.; Winnik, M. A. J. Phys. Chem. B 2013, 117, 8659-8672). Here, we build upon our DBM and show its practical application to evaluate calorimetry titrations of receptors with multiple sites independently of the titration direction. Specifically, we present a set of ordinary differential equations (ODEs) with the general form d[S]/dV that can be integrated numerically to calculate the equilibrium concentrations of free and bound species S at every injection step and, subsequently, to evaluate the volume-normalized heat signal (δQ(V) = δq/dV) of direct and reverse calorimetry titrations. Additionally, we identify factors that influence the shape of the titration curve and can be used to optimize the initial concentrations of titrant and analyte. We demonstrate the flexibility of our updated DBM by applying these differentials and a global regression analysis to direct and reverse calorimetric titrations of gadolinium ions with multidentate ligands of increasing denticity, namely, diglycolic acid (DGA), citric acid (CIT), and nitrilotriacetic acid (NTA), and use statistical tests to validate the stoichiometries for the metal-ligand pairs studied.

  5. LETTER TO THE EDITOR: Fractal diffusion coefficient from dynamical zeta functions

    NASA Astrophysics Data System (ADS)

    Cristadoro, Giampaolo

    2006-03-01

    Dynamical zeta functions provide a powerful method to analyse low-dimensional dynamical systems when the underlying symbolic dynamics is under control. On the other hand, even simple one-dimensional maps can show an intricate structure of the grammar rules that may lead to a non-smooth dependence of global observables on parameters changes. A paradigmatic example is the fractal diffusion coefficient arising in a simple piecewise linear one-dimensional map of the real line. Using the Baladi-Ruelle generalization of the Milnor-Thurnston kneading determinant, we provide the exact dynamical zeta function for such a map and compute the diffusion coefficient from its smallest zero.

  6. Simple and Automated Coulometric Titration of Acid Using Nonisolated Electrodes

    ERIC Educational Resources Information Center

    Kuntzleman, Thomas S.; Kenney, Joshua B.; Hasbrouck, Scott; Collins, Michael J.; Amend, John R.

    2011-01-01

    Coulometric titrations involve the quantification of analyte by measurements of current and time. In most coulometric titrations, the anode and cathode are placed in isolated cells that are connected by a salt bridge. By contrast, the experiments described here involve coulometric titrations (of acidic protons in solution) using a silver anode and…

  7. Determination of carbonate carbon in geological materials by coulometric titration

    USGS Publications Warehouse

    Engleman, E.E.; Jackson, L.L.; Norton, D.R.

    1985-01-01

    A coulometric titration is used for the determination of carbonate carbon in geological materials. Carbon dioxide is evolved from the sample by the addition of 2 M perchloric acid, with heating, and is determined by automated coulometric titration. The coulometric titration showed improved speed and precision with comparable accuracy to gravimetric and gasometric techniques. ?? 1985.

  8. Line identifications in the ultraviolet spectra of Tau Herculis, B5 IV, and Zeta Draconis, B6 III

    NASA Technical Reports Server (NTRS)

    Underhill, A. B.; Adelman, S. J.

    1976-01-01

    Tables of the lines found on two tracings each of the ultraviolet spectrum of Tau Her, B5 IV, and Zeta Dra, B6 III, made by the Copernicus satellite and possible identifications are given. The ranges 1025-1451A for Tau Her and 1035 to 1425A for Zeta Dra are covered by the U2 spectrometer at a resolution of 0.2A; the ranges 2028 to 2959A for Tau Her and 2000 to 3000A for Zeta Dra are covered by the V2 spectrometer at a resolution of 0.4A. The observed density of lines in the U2 region is 1.1 lines/A for Tau Her and 1.7 lines/A for Zeta Dra. In the V2 region it is 0.8 lines/A for Tau Her and 0.9 lines/A for Zeta Dra.

  9. The acid-base titration of montmorillonite

    NASA Astrophysics Data System (ADS)

    Bourg, I. C.; Sposito, G.; Bourg, A. C.

    2003-12-01

    Proton binding to clay minerals plays an important role in the chemical reactivity of soils (e.g., acidification, retention of nutrients or pollutants). If should also affect the performance of clay barriers for waste disposal. The surface acidity of clay minerals is commonly modelled empirically by assuming generic amphoteric surface sites (>SOH) on a flat surface, with fitted site densities and acidity constant. Current advances in experimental methods (notably spectroscopy) are rapidly improving our understanding of the structure and reactivity of the surface of clay minerals (arrangement of the particles, nature of the reactive surface sites, adsorption mechanisms). These developments are motivated by the difficulty of modelling the surface chemistry of mineral surfaces at the macro-scale (e.g., adsorption or titration) without a detailed (molecular-scale) picture of the mechanisms, and should be progressively incorporated into surface complexation models. In this view, we have combined recent estimates of montmorillonite surface properties (surface site density and structure, edge surface area, surface electrostatic potential) with surface site acidities obtained from the titration of alpha-Al2O3 and SiO2, and a novel method of accounting for the unknown initial net proton surface charge of the solid. The model predictions were compared to experimental titrations of SWy-1 montmorillonite and purified MX-80 bentonite in 0.1-0.5 mol/L NaClO4 and 0.005-0.5 mol/L NaNO3 background electrolytes, respectively. Most of the experimental data were appropriately described by the model after we adjusted a single parameter (silanol sites on the surface of montmorillonite were made to be slightly more acidic than those of silica). At low ionic strength and acidic pH the model underestimated the buffering capacity of the montmorillonite, perhaps due to clay swelling or to the interlayer adsorption of dissolved aluminum. The agreement between our model and the experimental

  10. In silico concurrent multisite pH titration in proteins.

    PubMed

    Hu, Hao; Shen, Lin

    2014-07-30

    The concurrent proton binding at multiple sites in macromolecules such as proteins and nucleic acids is an important yet challenging problem in biochemistry. We develop an efficient generalized Hamiltonian approach to attack this issue. Based on the previously developed generalized-ensemble methods, an effective potential energy is constructed which combines the contributions of all (relevant) protonation states of the molecule. The effective potential preserves important phase regions of all states and, thus, allows efficient sampling of these regions in one simulation. The need for intermediate states in alchemical free energy simulations is greatly reduced. Free energy differences between different protonation states can be determined accurately and enable one to construct the grand canonical partition function. Therefore, the complicated concurrent multisite proton titration process of protein molecules can be satisfactorily simulated. Application of this method to the simulation of the pKa of Glu49, Asp50, and C-terminus of bovine pancreatic trypsin inhibitor shows reasonably good agreement with published experimental work. This method provides an unprecedented vivid picture of how different protonation states change their relative population upon pH titration. We believe that the method will be very useful in deciphering the molecular mechanism of pH-dependent biomolecular processes in terms of a detailed atomistic description. Copyright © 2014 Wiley Periodicals, Inc.

  11. The Potentiometric Titration of Filtrates from the Bachmann Process

    DTIC Science & Technology

    1942-06-23

    SCIENTIFIC RESEARCH AND DEVELOP11ENT The Potentiometric Titration of Filtrates from the Bachmann Process (OD-12) by F. C. Whitmore OSRD No. 654... Potentiometric Titration of Synthetic Mixtures. A? Nitric Acid-Acetic Acid. A sample of 60 ml. glacial acetic acid war diluted to 200 ml. with distilled...i4flinflr?fj3 TADLE 1 CO) |S?lDBnTl» POTENTIOMETRIC TITRATION OF SYNTHETIC t’.IXTURES WITH CONCENTRATED AJKDNIUM HYDROXIDE A; unonium HNO-j- AcOfi Ky

  12. Comparison of VFA titration procedures used for monitoring the biogas process.

    PubMed

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of

  13. A novel approach for high precision rapid potentiometric titrations: application to hydrazine assay.

    PubMed

    Sahoo, P; Malathi, N; Ananthanarayanan, R; Praveen, K; Murali, N

    2011-11-01

    We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ~2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO(3) in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors. © 2011 American Institute of Physics

  14. A novel approach for high precision rapid potentiometric titrations: Application to hydrazine assay

    NASA Astrophysics Data System (ADS)

    Sahoo, P.; Malathi, N.; Ananthanarayanan, R.; Praveen, K.; Murali, N.

    2011-11-01

    We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ˜2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO3 in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors.

  15. Zeta Function Regularization in Casimir Effect Calculations and J. S. DOWKER's Contribution

    NASA Astrophysics Data System (ADS)

    Elizalde, Emilio

    2012-06-01

    A summary of relevant contributions, ordered in time, to the subject of operator zeta functions and their application to physical issues is provided. The description ends with the seminal contributions of Stephen Hawking and Stuart Dowker and collaborators, considered by many authors as the actual starting point of the introduction of zeta function regularization methods in theoretical physics, in particular, for quantum vacuum fluctuation and Casimir effect calculations. After recalling a number of the strengths of this powerful and elegant method, some of its limitations are discussed. Finally, recent results of the so-called operator regularization procedure are presented.

  16. Zeta Function Regularization in Casimir Effect Calculations and J. S. Dowker's Contribution

    NASA Astrophysics Data System (ADS)

    Elizalde, Emilio

    2012-07-01

    A summary of relevant contributions, ordered in time, to the subject of operator zeta functions and their application to physical issues is provided. The description ends with the seminal contributions of Stephen Hawking and Stuart Dowker and collaborators, considered by many authors as the actual starting point of the introduction of zeta function regularization methods in theoretical physics, in particular, for quantum vacuum fluctuation and Casimir effect calculations. After recalling a number of the strengths of this powerful and elegant method, some of its limitations are discussed. Finally, recent results of the so called operator regularization procedure are presented.

  17. DIFFERENTIAL THERMOMETRIC TITRATIONS AND THE DETERMINATION OF HEATS OF REACTION,

    DTIC Science & Technology

    TITRATION , THERMISTORS), (*HEAT OF REACTION, TITRATION ), SILVER COMPOUNDS, NITRATES, AMMONIA, PYRIDINES, ETHYLENEDIAMINE, AMINES, ALCOHOLS, BUTANOLS, PROPANOLS, SODIUM COMPOUNDS, HYDROXIDES, TEST METHODS

  18. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Potassium Ferricyanide Titration..., App. A Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium... buffered sulfide solution is titrated with standard potassium ferricyanide solution in the presence of a...

  19. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Potassium Ferricyanide Titration..., App. A Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium... buffered sulfide solution is titrated with standard potassium ferricyanide solution in the presence of a...

  20. A new sensor for thermometric titrations.

    PubMed

    Najib, Fadhil M; Zewar, Sardir; Abdulla, Ahmad M

    2007-01-15

    A new thermometric sensor, which is a transistor (OC71), has been introduced to follow thermometric titrations successfully to clear end points. The sensor was suitable in both normal and differential modes of titration. It is possible to titrate down to 1.32micromol of HCl and 26.4micromol of H(3)BO(3)in a final 20ml solution with accuracy and precision of 1%, 2.2% and 1.4%, 2.2%, respectively. The sensor, in association with a pH glass electrode, was used for the determination of pK values of some well established weak acids such as, acetic acid (4.77), phosphoric acid (pK(1)=2.18, pK(2)=7.20 and pK(3)=12.32) as well as for a very weak acid of uncertain pK values H(3)BO(3) (pK(1)=9.20, pK(2)=12.7 and pK(3)=13.80). The sensor was also examined for kinetic catalytic determination of iron(III) in water, milk and pharmaceuticals.

  1. Predicting prolonged dose titration in patients starting warfarin.

    PubMed

    Finkelman, Brian S; French, Benjamin; Bershaw, Luanne; Brensinger, Colleen M; Streiff, Michael B; Epstein, Andrew E; Kimmel, Stephen E

    2016-11-01

    Patients initiating warfarin therapy generally experience a dose-titration period of weeks to months, during which time they are at higher risk of both thromboembolic and bleeding events. Accurate prediction of prolonged dose titration could help clinicians determine which patients might be better treated by alternative anticoagulants that, while more costly, do not require dose titration. A prediction model was derived in a prospective cohort of patients starting warfarin (n = 390), using Cox regression, and validated in an external cohort (n = 663) from a later time period. Prolonged dose titration was defined as a dose-titration period >12 weeks. Predictor variables were selected using a modified best subsets algorithm, using leave-one-out cross-validation to reduce overfitting. The final model had five variables: warfarin indication, insurance status, number of doctor's visits in the previous year, smoking status, and heart failure. The area under the ROC curve (AUC) in the derivation cohort was 0.66 (95%CI 0.60, 0.74) using leave-one-out cross-validation, but only 0.59 (95%CI 0.54, 0.64) in the external validation cohort, and varied across clinics. Including genetic factors in the model did not improve the area under the ROC curve (0.59; 95%CI 0.54, 0.65). Relative utility curves indicated that the model was unlikely to provide a clinically meaningful benefit compared with no prediction. Our results suggest that prolonged dose titration cannot be accurately predicted in warfarin patients using traditional clinical, social, and genetic predictors, and that accurate prediction will need to accommodate heterogeneities across clinical sites and over time. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Risk factors associated with treatment discontinuation and down-titration in type 2 diabetes patients treated with sulfonylureas.

    PubMed

    Iglay, Kristy; Qiu, Ying; Steve Fan, Chun-Po; Li, Zhiyi; Tang, Jackson; Laires, Pedro

    2016-09-01

    Sulfonylurea therapy among patients with type 2 diabetes mellitus (T2DM) can be disrupted due to adverse events, including hypoglycemia. A retrospective study using the MarketScan claims database quantified the frequency of sulfonylurea discontinuation or down-titration and identified associated risk factors. Adult patients with an index sulfonylurea prescription between 2008 and 2012 and 1 year continuous enrollment pre- and post-index were included. Therapy changes assessed over 1 year post-index included discontinuation and down-titration. Discontinuation occurred if the date of a fill was >90 days from the end date of the preceding fill. Down-titration occurred when a fill had a lower equivalent dose than the fill on the index date. Kaplan-Meier methods estimated the probability of either discontinuation or down-titration over 12 months, and Cox regression models identified associated risk factors. A total of 104,082 sulfonylurea users were included in the study and the probability of either discontinuation or down-titration at 3, 6 and 12 months was 23.2%, 38.9%, and 52.3%, respectively. Major risk factors associated with therapy changes included post-index hypoglycemia (discontinuation hazard ratio [HR] = 1.78 [1.68, 1.89]; down-titration HR =2.79 [2.40, 3.23]) and concomitant use of insulin (discontinuation HR =1.48 [1.40, 1.57]; down-titration HR =1.82 [1.56, 2.11]). Other risk factors included younger age, female gender, use of second generation sulfonylureas, prior cardiovascular comorbidity and liver disease. The study was not able to assess unreported, potentially mild cases of hypoglycemia, nor was it able to evaluate the association between changes in therapy and HbA1c levels or body weight. More than half of T2DM patients who initiated sulfonylurea therapy discontinued or down-titrated within 1 year. Insulin use and hypoglycemia were associated with sulfonylurea therapy change.

  3. Tunnel determinants from spectral zeta functions. Instanton effects in quantum mechanics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Izquierdo, A. Alonso; Guilarte, J. Mateos

    2014-07-23

    In this paper we develop an spectral zeta function regularization procedure on the determinants of instanton fluctuation operators that describe the semi-classical order of tunnel effects between degenerate vacua.

  4. Microscale pH Titrations Using an Automatic Pipet.

    ERIC Educational Resources Information Center

    Flint, Edward B.; Kortz, Carrie L.; Taylor, Max A.

    2002-01-01

    Presents a microscale pH titration technique that utilizes an automatic pipet. A small aliquot (1-5 mL) of the analyte solution is titrated with repeated additions of titrant, and the pH is determined after each delivery. The equivalence point is determined graphically by either the second derivative method or a Gran plot. The pipet can be…

  5. Thermometric titrations of amines with nitrosyl perchlorate in acetonitrile solvent.

    PubMed

    Gündüz, T; Kiliç, E; Cakirer, O

    1996-05-01

    Thirteen aliphatic and four aromatic amines, namely diethylamine, triethylamine, n-propylamine, di-n-propylamine, tri-n-butylamine, isopropylamine, di-isopropylamine, n-butylamine, di-n-butylamine, tri-n-butylamine, isobutylamine, sec-butylamine, tert-butylamine, aniline, N,N-dimethylaniline, 2-nitroaniline and 4-nitroaniline were titrated thermometrically with nitrosyl perchlorate in acetonitrile solvent. All the aliphatic amines gave very well-shaped thermometric titration curves. The calculated recovery values of the amines were very good. In comparison, the aromatic amines, aniline and N,N-dimethylaniline gave rather well-shaped titration curves, but the recovery values were fairly low. 2-Nitro- and 4-nitro anilines gave no thermometric response at all. The heats of reaction of the amines with nitrosyl perchlorate are rather high. However, the average heat of reaction of the aromatic amines is approximately two-thirds that of the average heat of the aliphatic amines. To support this method all the amines were also titrated potentiometrically and very similar results to those obtained with the thermometric method are seen. The nitrosyl ion is a Lewis acid, strong enough to titrate quantitatively aliphatic amines in acetonitrile solvent, but not strong enough to titrate aromatic amines at the required level in the same solvent.

  6. Spectrophotometric Titration of a Mixture of Calcium and Magnesium.

    ERIC Educational Resources Information Center

    Fulton, Robert; And Others

    1986-01-01

    Describes a spectrophotometric titration experiment which uses a manual titration spectrophotometer and manually operated buret, rather than special instrumentation. Identifies the equipment, materials, and procedures needed for the completion of the experiment. Recommends the use of this experiment in introductory quantitative analysis…

  7. Filtrates & Residues: Olfactory Titration.

    ERIC Educational Resources Information Center

    Wood, John T.; Eddy, Roberta M.

    1996-01-01

    Presents an experiment that uses a unique acid-base indicator--the odor of raw onion--to indicate the end point of the titration of sodium hydroxide with hydrochloric acid. Allows the student to detect the completion of the neutralization reaction by olfaction rather than sight. (JRH)

  8. The Acid-Base Titration of a Very Weak Acid: Boric Acid

    ERIC Educational Resources Information Center

    Celeste, M.; Azevedo, C.; Cavaleiro, Ana M. V.

    2012-01-01

    A laboratory experiment based on the titration of boric acid with strong base in the presence of d-mannitol is described. Boric acid is a very weak acid and direct titration with NaOH is not possible. An auxiliary reagent that contributes to the release of protons in a known stoichiometry facilitates the acid-base titration. Students obtain the…

  9. A Full Automatic Device for Sampling Small Solution Volumes in Photometric Titration Procedure Based on Multicommuted Flow System

    PubMed Central

    Borges, Sivanildo S.; Vieira, Gláucia P.; Reis, Boaventura F.

    2007-01-01

    In this work, an automatic device to deliver titrant solution into a titration chamber with the ability to determine the dispensed volume of solution, with good precision independent of both elapsed time and flow rate, is proposed. A glass tube maintained at the vertical position was employed as a container for the titrant solution. Electronic devices were coupled to the glass tube in order to control its filling with titrant solution, as well as the stepwise solution delivering into the titration chamber. The detection of the titration end point was performed employing a photometer designed using a green LED (λ=545 nm) and a phototransistor. The titration flow system comprised three-way solenoid valves, which were assembled to allow that the steps comprising the solution container loading and the titration run were carried out automatically. The device for the solution volume determination was designed employing an infrared LED (λ=930 nm) and a photodiode. When solution volume delivered from proposed device was within the range of 5 to 105 μl, a linear relationship (R = 0.999) between the delivered volumes and the generated potential difference was achieved. The usefulness of the proposed device was proved performing photometric titration of hydrochloric acid solution with a standardized sodium hydroxide solution and using phenolphthalein as an external indicator. The achieved results presented relative standard deviation of 1.5%. PMID:18317510

  10. Amperometric, Bipotentiometric, and Coulometric Titration.

    ERIC Educational Resources Information Center

    Stock, John T.

    1980-01-01

    Discusses recent review articles in various kinds of titration. Also discusses new research in apparatus and methodology, acid-base reactions, precipitation and complexing reactions, oxidation-reduction reactions, and nomenclature. Cites 338 references. (CS)

  11. Zeta functions on tori using contour integration

    NASA Astrophysics Data System (ADS)

    Elizalde, Emilio; Kirsten, Klaus; Robles, Nicolas; Williams, Floyd

    2015-12-01

    A new, seemingly useful presentation of zeta functions on complex tori is derived by using contour integration. It is shown to agree with the one obtained by using the Chowla-Selberg series formula, for which an alternative proof is thereby given. In addition, a new proof of the functional determinant on the torus results, which does not use the Kronecker first limit formula nor the functional equation of the non-holomorphic Eisenstein series. As a bonus, several identities involving the Dedekind eta function are obtained as well.

  12. Digital movie-based on automatic titrations.

    PubMed

    Lima, Ricardo Alexandre C; Almeida, Luciano F; Lyra, Wellington S; Siqueira, Lucas A; Gaião, Edvaldo N; Paiva Junior, Sérgio S L; Lima, Rafaela L F C

    2016-01-15

    This study proposes the use of digital movies (DMs) in a flow-batch analyzer (FBA) to perform automatic, fast and accurate titrations. The term used for this process is "Digital movie-based on automatic titrations" (DMB-AT). A webcam records the DM during the addition of the titrant to the mixing chamber (MC). While the DM is recorded, it is decompiled into frames ordered sequentially at a constant rate of 26 frames per second (FPS). The first frame is used as a reference to define the region of interest (ROI) of 28×13pixels and the R, G and B values, which are used to calculate the Hue (H) values for each frame. The Pearson's correlation coefficient (r) is calculated between the H values of the initial frame and each subsequent frame. The titration curves are plotted in real time using the r values and the opening time of the titrant valve. The end point is estimated by the second derivative method. A software written in C language manages all analytical steps and data treatment in real time. The feasibility of the method was attested by application in acid/base test samples and edible oils. Results were compared with classical titration and did not present statistically significant differences when the paired t-test at the 95% confidence level was applied. The proposed method is able to process about 117-128 samples per hour for the test and edible oil samples, respectively, and its precision was confirmed by overall relative standard deviation (RSD) values, always less than 1.0%. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Antiepileptic Drug Titration and Related Health Care Resource Use and Costs.

    PubMed

    Fishman, Jesse; Kalilani, Linda; Song, Yan; Swallow, Elyse; Wild, Imane

    2018-02-27

    Unexpected breakthrough seizures resulting from suboptimal antiepileptic drug (AED) dosing during the titration period, as well as adverse events resulting from rapid AED titration, may influence the titration schedule and significantly increase health care resource use (HRU) and health care costs. To assess the relationship between AEDs, HRU, and costs during AED titration and maintenance. Practicing neurologists were recruited from a nationwide panel to provide up to 3 patient records each for this retrospective medical chart review. Patients with epilepsy who were aged ≥ 18 years and had initiated an AED between January 1, 2014, and January 1, 2016, were followed for 6 months from AED initiation. Titration duration was the time from AED initiation to the beginning of treatment maintenance as determined by the physician. Outcomes were epilepsy-specific HRU (hospitalizations, emergency department visits, outpatient visits, physician referral, laboratory testing/diagnostic imaging, and phone calls) and related costs that occurred during the titration or maintenance treatment periods. Of 811 patients, 156, 128, 125, 120, 114, 107, and 61 initiated the following AEDs: levetiracetam, lamotrigine, lacosamide, valproate, topiramate, carbamazepine, and phenytoin, respectively. Most patients (619/803 [77.1%] with complete AED data) received monotherapy. Baseline characteristics were similar across AEDs (mean [SD] age, 36.6 [14.4] years; 59.0% male). Kaplan-Meier estimates of titration duration ranged from 3.3 weeks (phenytoin) to 8.1 weeks (lamotrigine). From titration to maintenance, the overall incidence of HRU per person-month decreased 54.5%-89.3% for each HRU measure except outpatient visits (24.6% decrease). Total epilepsy-related costs decreased from $80.48 to $42.77 per person-month, or 46.9% from titration to maintenance. AED titration periods had higher HRU rates and costs than AED maintenance, suggesting that use of AEDs with shorter titration requirements

  14. Mapping Protein-Protein Interactions of the Resistance-Related Bacterial Zeta Toxin-Epsilon Antitoxin Complex (ε₂ζ₂) with High Affinity Peptide Ligands Using Fluorescence Polarization.

    PubMed

    Fernández-Bachiller, María Isabel; Brzozowska, Iwona; Odolczyk, Norbert; Zielenkiewicz, Urszula; Zielenkiewicz, Piotr; Rademann, Jörg

    2016-07-16

    Toxin-antitoxin systems constitute a native survival strategy of pathogenic bacteria and thus are potential targets of antibiotic drugs. Here, we target the Zeta-Epsilon toxin-antitoxin system, which is responsible for the stable maintenance of certain multiresistance plasmids in Gram-positive bacteria. Peptide ligands were designed on the basis of the ε₂ζ₂ complex. Three α helices of Zeta forming the protein-protein interaction (PPI) site were selected and peptides were designed conserving the residues interacting with Epsilon antitoxin while substituting residues binding intramolecularly to other parts of Zeta. Designed peptides were synthesized with an N-terminal fluoresceinyl-carboxy-residue for binding assays and provided active ligands, which were used to define the hot spots of the ε₂ζ₂ complex. Further shortening and modification of the binding peptides provided ligands with affinities <100 nM, allowing us to determine the most relevant PPIs and implement a robust competition binding assay.

  15. Differential interaction and aggregation of 3-repeat and 4-repeat tau isoforms with 14-3-3{zeta} protein

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sadik, Golam; Tanaka, Toshihisa, E-mail: tanaka@psy.med.osaka-u.ac.jp; Kato, Kiyoko

    2009-05-22

    Tau isoforms, 3-repeat (3R) and 4-repeat tau (4R), are differentially involved in neuronal development and in several tauopathies. 14-3-3 protein binds to tau and 14-3-3/tau association has been found both in the development and in tauopathies. To understand the role of 14-3-3 in the differential regulation of tau isoforms, we have performed studies on the interaction and aggregation of 3R-tau and 4R-tau, either phosphorylated or unphosphorylated, with 14-3-3{zeta}. We show by surface plasmon resonance studies that the interaction between unphosphorylated 3R-tau and 14-3-3{zeta} is {approx}3-folds higher than that between unphosphorylated 4R-tau and 14-3-3{zeta}. Phosphorylation of tau by protein kinase Amore » (PKA) increases the affinity of both 3R- and 4R-tau for 14-3-3{zeta} to a similar level. An in vitro aggregation assay employing both transmission electron microscopy and fluorescence spectroscopy revealed the aggregation of unphosphorylated 4R-tau to be significantly higher than that of unphosphorylated 3R-tau following the induction of 14-3-3{zeta}. The filaments formed from 3R- and 4R-tau were almost similar in morphology. In contrast, the aggregation of both 3R- and 4R-tau was reduced to a similar low level after phosphorylation with PKA. Taken together, these results suggest that 14-3-3{zeta} exhibits a similar role for tau isoforms after PKA-phosphorylation, but a differential role for unphosphorylated tau. The significant aggregation of 4R-tau by 14-3-3{zeta} suggests that 14-3-3 may act as an inducer in the generation of 4R-tau-predominant neurofibrillary tangles in tauopathies.« less

  16. Carbon and nitrogen abundances in the supergiants HD 93840 and zeta Per

    NASA Technical Reports Server (NTRS)

    Massa, Derck; Altner, Bruce; Wynne, David; Lamers, H. J. G. L. M.

    1990-01-01

    The BN supergiant HD 93840 is shown to have the same temperature and surface gravity as the normal Bi Ib zeta Per. Differential abundance analysis of their C 4 and N 5 wind line profiles are found. The results are independent of the usual model atmosphere analyses and, therefore, a valuable check on them. Ratios for the C and N surface abundances in HD 93840 compared to Per of 1:10 and 4.6:1 are found respectively. By introducing a simple model for the compositions of both atmospheres the fraction of material in each atmosphere which has undergone CNO processing, more than 90 percent for HD 93840 and less than about 15 percent for zeta Per, is derived.

  17. In vitro phosphorylation of insulin receptor substrate 1 by protein kinase C-zeta: functional analysis and identification of novel phosphorylation sites.

    PubMed

    Sommerfeld, Mark R; Metzger, Sabine; Stosik, Magdalene; Tennagels, Norbert; Eckel, Jürgen

    2004-05-18

    Protein kinase C-zeta (PKC-zeta) participates both in downstream insulin signaling and in the negative feedback control of insulin action. Here we used an in vitro approach to identify PKC-zeta phosphorylation sites within insulin receptor substrate 1 (IRS-1) and to characterize the functional implications. A recombinant IRS-1 fragment (rIRS-1(449)(-)(664)) containing major tyrosine motifs for interaction with phosphatidylinositol (PI) 3-kinase strongly associated to the p85alpha subunit of PI 3-kinase after Tyr phosphorylation by the insulin receptor. Phosphorylation of rIRS-1(449)(-)(664) by PKC-zeta induced a prominent inhibition of this process with a mixture of classical PKC isoforms being less effective. Both PKC-zeta and the classical isoforms phosphorylated rIRS-1(449)(-)(664) on Ser(612). However, modification of this residue did not reduce the affinity of p85alpha binding to pTyr-containing peptides (amino acids 605-615 of rat IRS-1), as determined by surface plasmon resonance. rIRS-1(449)(-)(664) was then phosphorylated by PKC-zeta using [(32)P]ATP and subjected to tryptic phosphopeptide mapping based on two-dimensional HPLC coupled to mass spectrometry. Ser(498) and Ser(570) were identified as novel phosphoserine sites targeted by PKC-zeta. Both sites were additionally confirmed by phosphopeptide mapping of the corresponding Ser --> Ala mutants of rIRS-1(449)(-)(664). Ser(570) was specifically targeted by PKC-zeta, as shown by immunoblotting with a phosphospecific antiserum against Ser(570) of IRS-1. Binding of p85alpha to the S570A mutant was less susceptible to inhibition by PKC-zeta, when compared to the S612A mutant. In conclusion, our in vitro data demonstrate a strong inhibitory action of PKC-zeta at the level of IRS-1/PI 3-kinase interaction involving multiple serine phosphorylation sites. Whereas Ser(612) appears not to participate in the negative control of insulin signaling, Ser(570) may at least partly contribute to this process.

  18. Development and validation of a simplified titration method for monitoring volatile fatty acids in anaerobic digestion.

    PubMed

    Sun, Hao; Guo, Jianbin; Wu, Shubiao; Liu, Fang; Dong, Renjie

    2017-09-01

    The volatile fatty acids (VFAs) concentration has been considered as one of the most sensitive process performance indicators in anaerobic digestion (AD) process. However, the accurate determination of VFAs concentration in AD processes normally requires advanced equipment and complex pretreatment procedures. A simplified method with fewer sample pretreatment procedures and improved accuracy is greatly needed, particularly for on-site application. This report outlines improvements to the Nordmann method, one of the most popular titrations used for VFA monitoring. The influence of ion and solid interfering subsystems in titrated samples on results accuracy was discussed. The total solid content in titrated samples was the main factor affecting accuracy in VFA monitoring. Moreover, a high linear correlation was established between the total solids contents and VFA measurement differences between the traditional Nordmann equation and gas chromatography (GC). Accordingly, a simplified titration method was developed and validated using a semi-continuous experiment of chicken manure anaerobic digestion with various organic loading rates. The good fitting of the results obtained by this method in comparison with GC results strongly supported the potential application of this method to VFA monitoring. Copyright © 2017. Published by Elsevier Ltd.

  19. Catalytic properties of an expressed and purified higher plant type zeta-carotene desaturase from Capsicum annuum.

    PubMed

    Breitenbach, J; Kuntz, M; Takaichi, S; Sandmann, G

    1999-10-01

    The zeta-carotene desaturase from Capsicum annuum (EC 1.14.99.-) was expressed in Escherichia coli, purified and characterized biochemically. The enzyme acts as a monomer with lipophilic quinones as cofactors. Km values for the substrate zeta-carotene or the intermediate neurosporene in the two-step desaturation reaction are almost identical. Product analysis showed that different lycopene isomers are formed, including substantial amounts of the all-trans form, together with 7,7',9,9'-tetracis prolycopene via the corresponding neurosporene isomers. The application of different geometric isomers as substrates revealed that the zeta-carotene desaturase has no preference for certain isomers and that the nature of the isomers formed during catalysis depends strictly on the isomeric composition of the substrate.

  20. Automatic photometric titrations of calcium and magnesium in carbonate rocks

    USGS Publications Warehouse

    Shapiro, L.; Brannock, W.W.

    1955-01-01

    Rapid nonsubjective methods have been developed for the determination of calcium and magnesium in carbonate rocks. From a single solution of the sample, calcium is titrated directly, and magnesium is titrated after a rapid removal of R2O3 and precipitation of calcium as the tungstate. A concentrated and a dilute solution of disodium ethylenediamine tetraacetate are used as titrants. The concentrated solution is added almost to the end point, then the weak solution is added in an automatic titrator to determine the end point precisely.

  1. Preparation and physico-chemical characterization of β-cyclodextrin incorporated chitosan biosorbent beads with potential environmental applications

    NASA Astrophysics Data System (ADS)

    Munim, Somayyah Abdul; Tahir Saddique, Muhammad; Raza, Zulfiqar Ali; Majeed, Muhammad Irfan

    2018-06-01

    Biosorption is one of the most efficient and feasible methods for eliminating noxious wastes from the aqueous systems. The use of non-hazardous, low-cost and biodegradable chitosan as a biosorbent is of significant importance in the above context. Present study was aimed to develop a β-cyclodextrin (β-CD) incorporated chitosan biosorbent in the form of beads. The prepared biosorbent beads were characterized using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), x-ray diffraction (XRD) analysis, and thermo gravimetric analysis (TGA). The values of point of zero charge (PZC) of chitosan and β-CD incorporated chitosan beads were determined in the presence of an electrolyte by means of different methods including mass titration, salt addition and zeta potential ones. The SEM images exhibited roughened and porous morphologies which could enhance the adsorption of metal ions. The values of PZC of chitosan and β-CD incorporated chitosan biosorbent beads were found to be 6.38 and 7.12, respectively.

  2. The Mobile Insulin Titration Intervention (MITI) for Insulin Glargine Titration in an Urban, Low-Income Population: Randomized Controlled Trial Protocol.

    PubMed

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-03-13

    Patients on insulin glargine typically visit a clinician to obtain advice on how to adjust their insulin dose. These multiple clinic visits can be costly and time-consuming, particularly for low-income patients. It may be feasible to achieve insulin titration through text messages and phone calls with patients instead of face-to-face clinic visits. The objectives of this study are to (1) evaluate if the Mobile Insulin Titration Intervention (MITI) is clinically effective by helping patients reach their optimal dose of insulin glargine, (2) determine if the intervention is feasible within the setting and population, (3) assess patient satisfaction with the intervention, and (4) measure the costs associated with this intervention. This is a pilot study evaluating an approach to insulin titration using text messages and phone calls among patients with insulin-dependent type 2 diabetes in the outpatient medical clinic of Bellevue Hospital Center, a safety-net hospital in New York City. Patients will be randomized in a 1:1 ratio to either the MITI arm (texting/phone call intervention) or the usual-care arm (in-person clinic visits). Using a Web-based platform, weekday text messages will be sent to patients in the MITI arm, asking them to text back their fasting blood glucose values. In addition to daily reviews for alarm values, a clinician will rereview the texted values weekly, consult our physician-approved titration algorithm, and call the patients with advice on how to adjust their insulin dose. The primary outcome will be whether or not a patient reaches his/her optimal dose of insulin glargine within 12 weeks. Recruitment for this study occurred between June 2013 and December 2014. We are continuing to collect intervention and follow-up data from our patients who are currently enrolled. The results of our data analysis are expected to be available in 2015. This study explores the use of widely-available text messaging and voice technologies for insulin titration

  3. Asymptotic analysis on a pseudo-Hermitian Riemann-zeta Hamiltonian

    NASA Astrophysics Data System (ADS)

    Bender, Carl M.; Brody, Dorje C.

    2018-04-01

    The differential-equation eigenvalue problem associated with a recently-introduced Hamiltonian, whose eigenvalues correspond to the zeros of the Riemann zeta function, is analyzed using Fourier and WKB analysis. The Fourier analysis leads to a challenging open problem concerning the formulation of the eigenvalue problem in the momentum space. The WKB analysis gives the exact asymptotic behavior of the eigenfunction.

  4. Entire-Dataset Analysis of NMR Fast-Exchange Titration Spectra: A Mg2+ Titration Analysis for HIV-1 Ribonuclease H Domain.

    PubMed

    Karki, Ichhuk; Christen, Martin T; Spiriti, Justin; Slack, Ryan L; Oda, Masayuki; Kanaori, Kenji; Zuckerman, Daniel M; Ishima, Rieko

    2016-12-15

    This article communicates our study to elucidate the molecular determinants of weak Mg 2+ interaction with the ribonuclease H (RNH) domain of HIV-1 reverse transcriptase in solution. As the interaction is weak (a ligand-dissociation constant >1 mM), nonspecific Mg 2+ interaction with the protein or interaction of the protein with other solutes that are present in the buffer solution can confound the observed Mg 2+ -titration data. To investigate these indirect effects, we monitored changes in the chemical shifts of backbone amides of RNH by recording NMR 1 H- 15 N heteronuclear single-quantum coherence spectra upon titration of Mg 2+ into an RNH solution. We performed the titration under three different conditions: (1) in the absence of NaCl, (2) in the presence of 50 mM NaCl, and (3) at a constant 160 mM Cl - concentration. Careful analysis of these three sets of titration data, along with molecular dynamics simulation data of RNH with Na + and Cl - ions, demonstrates two characteristic phenomena distinct from the specific Mg 2+ interaction with the active site: (1) weak interaction of Mg 2+ , as a salt, with the substrate-handle region of the protein and (2) overall apparent lower Mg 2+ affinity in the absence of NaCl compared to that in the presence of 50 mM NaCl. A possible explanation may be that the titrated MgCl 2 is consumed as a salt and interacts with RNH in the absence of NaCl. In addition, our data suggest that Na + increases the kinetic rate of the specific Mg 2+ interaction at the active site of RNH. Taken together, our study provides biophysical insight into the mechanism of weak metal interaction on a protein.

  5. Amperometric, Bipotentiometric, and Coulometric Titration.

    ERIC Educational Resources Information Center

    Stock, John T.

    1984-01-01

    Reviews literature on amperometric, bipotentiometric, and coulometric titration methods examining: apparatus and methodology; acid-base reactions; precipitation and complexing reactions (considering methods involving silver, mercury, EDTA or analogous reagents, and other organic compounds); and oxidation-reduction reactions (considering methods…

  6. A Low-Cost Device for Automatic Photometric Titrations

    NASA Astrophysics Data System (ADS)

    Rocha, Fábio R. P.; Reis, Boaventura F.

    2000-02-01

    Electronics is an important topic in chemistry courses. However, the introduction of basic concepts is often difficult and the lab instruments are frequently seen as "black boxes". To address this problem, we propose the construction of a simple, low-cost (about $150 U.S.) automatic photometric titrator employing a light-emitting diode (LED) and a phototransistor. The electronic circuit can be assembled by the students themselves. The device was employed to implement a common procedure in chemical labs, making feasible the introduction of concepts related to electronics in undergraduate chemistry courses. The titrator is able to work automatically, since a feedback system permits stopping the addition of titrant solution when the end-point is achieved. With this demonstration, it can be stressed that automatic procedures can be implemented without expensive instruments. Additionally, a classical procedure becomes more attractive to the students and its importance to chemical analysis can be emphasized. The feasibility of the titrator was demonstrated by acid-base titrations of HCl solutions with NaOH in the presence of phenolphthalein and by iodimetric determination of ascorbic acid in vitamin C tablets and lemon juice. Precise results (0.7% relative standard deviation, n = 10) in agreement at the 95% confidence level with those attained by a conventional procedure were obtained.

  7. Graphical evaluation of complexometric titration curves.

    PubMed

    Guinon, J L

    1985-04-01

    A graphical method, based on logarithmic concentration diagrams, for construction, without any calculations, of complexometric titration curves is examined. The titration curves obtained for different kinds of unidentate, bidentate and quadridentate ligands clearly show why only chelating ligands are usually used in titrimetric analysis. The method has also been applied to two practical cases where unidentate ligands are used: (a) the complexometric determination of mercury(II) with halides and (b) the determination of cyanide with silver, which involves both a complexation and a precipitation system; for this purpose construction of the diagrams for the HgCl(2)/HgCl(+)/Hg(2+) and Ag(CN)(2)(-)/AgCN/CN(-) systems is considered in detail.

  8. Fuzzy-PI-based centralised control of semi-isolated FP-SEPIC/ZETA BDC in a PV/battery hybrid system

    NASA Astrophysics Data System (ADS)

    Mahendran, Venmathi; Ramabadran, Ramaprabha

    2016-11-01

    Multiport converters with centralised controller have been most commonly used in stand-alone photovoltaic (PV)/battery hybrid system to supply the load smoothly without any disturbances. This study presents the performance analysis of four-port SEPIC/ZETA bidirectional converter (FP-SEPIC/ZETA BDC) using various types of centralised control schemes like Fuzzy tuned proportional integral controller (Fuzzy-PI), fuzzy logic controller (FLC) and conventional proportional integral (PI) controller. The proposed FP-SEPIC/ZETA BDC with various control strategy is derived for simultaneous power management of a PV source using distributed maximum power point tracking (DMPPT) algorithm, a rechargeable battery, and a load by means of centralised controller. The steady state and the dynamic response of the FP-SEPIC/ZETA BDC are analysed using three different types of controllers under line and load regulation. The Fuzzy-PI-based control scheme improves the dynamic response of the system when compared with the FLC and the conventional PI controller. The power balance between the ports is achieved by pseudorandom carrier modulation scheme. The response of the FP-SEPIC/ZETA BDC is also validated experimentally using hardware prototype model of 500 W system. The effectiveness of the control strategy is validated using simulation and experimental results.

  9. p62 modulates Akt activity via association with PKC{zeta} in neuronal survival and differentiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joung, Insil; Kim, Hak Jae; Kwon, Yunhee Kim

    2005-08-26

    p62 is a ubiquitously expressed phosphoprotein that interacts with a number of signaling molecules and a major component of neurofibrillary tangles in the brain of Alzheimer's disease patients. It has been implicated in important cellular functions such as cell proliferation and anti-apoptotic pathways. In this study, we have addressed the potential role of p62 during neuronal differentiation and survival using HiB5, a rat neuronal progenitor cell. We generated a recombinant adenovirus encoding T7-epitope tagged p62 to reliably transfer p62 cDNA into the neuronal cells. The results show that an overexpression of p62 led not only to neuronal differentiation, but alsomore » to decreased cell death induced by serum withdrawal in HiB5 cells. In this process p62-dependent Akt phosphorylation occurred via the release of Akt from PKC{zeta} by association of p62 and PKC{zeta}, which is known as a negative regulator of Akt activation. These findings indicate that p62 facilitates cell survival through novel signaling cascades that result in Akt activation. Furthermore, we found that p62 expression was induced during neuronal differentiation. Taken together, the data suggest p62 is a regulator of neuronal cell survival and differentiation.« less

  10. Rapid Inpatient Titration of Intravenous Treprostinil for Pulmonary Arterial Hypertension: Safe and Tolerable.

    PubMed

    El-Kersh, Karim; Ruf, Kathryn M; Smith, J Shaun

    There is no standard protocol for intravenous treprostinil dose escalation. In most cases, slow up-titration is performed in the outpatient setting. However, rapid up-titration in an inpatient setting is an alternative that provides opportunity for aggressive treatment of common side effects experienced during dose escalation. In this study, we describe our experience with inpatient rapid up-titration of intravenous treprostinil. This was a single-center, retrospective study in which we reviewed the data of subjects with pulmonary arterial hypertension treated at our center who underwent inpatient rapid up-titration of intravenous treprostinil. Our treprostinil dose escalation protocol included initiation at 2 ng·kg·min with subsequent up-titration by 1 ng·kg·min every 6 to 8 hours as tolerated by side effects. A total of 16 subjects were identified. Thirteen subjects were treprostinil naive (naive group), and 3 subjects were receiving subcutaneous treprostinil but were hospitalized for further intravenous up-titration of treprostinil dose (nonnaive group). In the naive group, the median maximum dose achieved was 20 ng·kg·min with an interquartile range (IQR) of 20-23 ng·kg·min. The median up-titration interval was 6 days (IQR: 4-9). In the nonnaive group, the median maximum dose achieved was 20 ng·kg·min (range: 17-30). The median up-titration interval was 8.5 days (range: 1.5-11). Overall, the median maximum dose achieved was 20 ng·kg·min (IQR: 20-23.5), and the median up-titration interval was 6 days (IQR: 4.6-9.25), with no reported significant adverse hemodynamic events. In patients with pulmonary arterial hypertension, rapid inpatient titration of intravenous treprostinil is safe and tolerable.

  11. Determination of sulphite in wine by coulometric titration.

    PubMed

    Lowinsohn, D; Bertotti, M

    2001-09-01

    A method for the determination of both free and bound S(IV) in white wine samples by coulometric titration with electrogenerated iodine is described, the S(IV) speciation being performed by extracting SO2 from samples acidified wiith hydrochloric acid. Titrations of samples treated with NaOH led to the total S(IV) concentration, the results being in agreement with the ones obtained by the distillation procedure as well as by using the classical Monier-Williams method. An average recovery of 97% was obtained for samples spiked with S(IV) in the range 0.4-1.2 mM, which demonstrated the validity of the proposed procedure. The repeatability was 1.3% and the limit of detection was estimated as 0.01 mM. Results from direct titrations of wine added to the electrochemical cell are reported, which give indications of the stability of adducts towards the reaction with iodine.

  12. GRANULATION IN THE PHOTOSPHERE OF {zeta} CYGNI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gray, David F., E-mail: dfgray@uwo.ca

    2012-05-15

    A series of 35 high-resolution spectra are used to measure the third-signature plot of the G8 III star, {zeta} Cygni, which shows convective velocities only 8% larger than the Sun. Bisector mapping yields a flux deficit, a measure of granulation contrast, typical of other giants. The observations also give radial velocities with errors {approx}30 m s{sup -1} and allow the orbit to be refined. Velocity excursions relative to the smooth orbital motion, possibly from the granulation, have values exceeding 200 m s{sup -1}. Temperature variations were looked for using line-depth ratios, but none were found.

  13. The spectral energy distribution of Zeta Puppis and HD 50896

    NASA Technical Reports Server (NTRS)

    Holm, A. V.; Cassinelli, J. P.

    1977-01-01

    The ultraviolet spectral energy distribution of the O5f star Zeta Pup and the WN5 star HD 50896 are derived from OAO-2 observations with the calibration of Bless, Code, and Fairchild (1976). An estimate of the interstellar reddening (0.12 magnitude) of the Wolf-Rayet star is determined from the size of the characteristic interstellar extinction bump at 4.6 inverse microns. After correction for extinction, both stars show a flat energy distribution in the ultraviolet. The distribution of HD 50896 from 1100 A to 2 microns is in good agreement with results of extended model atmospheres, but some uncertainty remains because of the interstellar-extinction correction. The absolute energy distribution of Zeta Pup is fitted by a 42,000-K plane-parallel model if the model's flux is adjusted for the effects of electron scattering in the stellar wind and for UV line blanketing that was determined empirically from high-resolution Copernicus satellite observations. To achieve this fit, it is necessary to push both the spectroscopically determined temperature and the ultraviolet calibration to the limits of their probable errors.

  14. Organization of the human [zeta]-crystallin/quinone reductase gene (CRYZ)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, P.; Rao, P.V.; Zigler, J.S. Jr.

    1994-05-15

    [zeta]-Crystallin is a protein highly expressed in the lens of guinea pigs and camels, where it comprises about 10% of the total soluble protein. It has recently been characterized as a novel quinone oxidoreductase present in a variety of mammalian tissues. The authors report here the isolation and characterization of the human [zeta]-crystallin gene (CRYZ) and its processed pseudogene. The functional gene is composed of nine exons and spans about 20 kb. The 5[prime]-flanking region of the gene is rich in G and C (58%) and lacks TATA and CAAT boxes. Previous analysis of the guinea pig gene revealed themore » presence of two different promoters, one responsible for the high lens-specific expression and the other for expression at the enzymatic level in numerous tissues. Comparative analysis with the guinea pig gene shows that a region of [approximately]2.5 kb that includes the promoter responsible for the high expression in the lens in guinea pig is not present in the human gene. 34 refs., 6 figs., 1 tab.« less

  15. Molecular basis of length polymorphism in the human zeta-globin gene complex.

    PubMed Central

    Goodbourn, S E; Higgs, D R; Clegg, J B; Weatherall, D J

    1983-01-01

    The length polymorphism between the human zeta-globin gene and its pseudogene is caused by an allele-specific variation in the copy number of a tandemly repeating 36-base-pair sequence. This sequence is related to a tandemly repeated 14-base-pair sequence in the 5' flanking region of the human insulin gene, which is known to cause length polymorphism, and to a repetitive sequence in intervening sequence (IVS) 1 of the pseudo-zeta-globin gene. Evidence is presented that the latter is also of variable length, probably because of differences in the copy number of the tandem repeat. The homology between the three length polymorphisms may be an indication of the presence of a more widespread group of related sequences in the human genome, which might be useful for generalized linkage studies. PMID:6308667

  16. Averages of ratios of the Riemann zeta-function and correlations of divisor sums

    NASA Astrophysics Data System (ADS)

    Conrey, Brian; Keating, Jonathan P.

    2017-10-01

    Nonlinearity has published articles containing a significant number-theoretic component since the journal was first established. We examine one thread, concerning the statistics of the zeros of the Riemann zeta function. We extend this by establishing a connection between the ratios conjecture for the Riemann zeta-function and a conjecture concerning correlations of convolutions of Möbius and divisor functions. Specifically, we prove that the ratios conjecture and an arithmetic correlations conjecture imply the same result. This provides new support for the ratios conjecture, which previously had been motivated by analogy with formulae in random matrix theory and by a heuristic recipe. Our main theorem generalises a recent calculation pertaining to the special case of two-over-two ratios.

  17. Persistent benefits of slow titration of paroxetine in a six-month follow-up.

    PubMed

    Olgiati, Paolo; Serretti, Alessandro

    2015-09-01

    Paroxetine titration may be difficult in older individuals as they are more sensitive to side effects. The current study extends to 6 months our previously published report in which paroxetine was started at 2.5 mg/day and slowly increased by 2.5 mg on alternate days (slow titration) or rapidly titrated to target dose from 10 mg/day (standard titration) in a naturalistic setting. Here, the follow-up period was extended to 26 weeks. We performed an intent-to-treat analysis of 47 subjects from the original sample (major depressive disorder and/or generalized anxiety disorder (GAD); >60 years of age). Missing evaluations were replaced by last observations carried forward. GAD was included as a stratification factor. Patients in whom paroxetine was slowly up-titrated were more likely to remit (84.0% vs 54.5%; p = 0.028) and had lower core depression (p = 0.0015) and psychic anxiety levels (p = 0.006) after 26 weeks. Dropout rate was 20% in the slow titration group compared with 77.3% in the standard titration arm (p < 0.001). Patients with GAD accounted for all significant associations. No substantial differences were reported between slow and standard titration groups in the subsample without GAD. Despite some limitations, these findings suggest that paroxetine treatment should be started at lower doses in older depressed patients and slowly up-titrated. This strategy would allow to increase antidepressant response and the likelihood of completing treatment cycle in patients with high anxiety levels and GAD comorbidity. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Studies of cellulose surfaces by titration and ESCA

    NASA Astrophysics Data System (ADS)

    Stenius, Per; Laine, Janne

    1994-01-01

    The surface properties of unbleached kraft pulp fibers of varying lignin content prepared by digestion with different amounts of excess alkali have been investigated using polyelectrolyte titration, potentiometric titration and ESCA. The surfaces contain two different acidic groups that dissociate completely above pH 7.5, one with pK ≈ 3.6 and one with pK ≈ 5.7. The amount of the latter group correlates directly with the amount of lignin in the pulp. The ESCA analysis indicates that the relative amount of carboxylic groups and alkyl carbon in the surface decreases as the lignin content decreases and also that material with high alkyl carbon content is enriched in the outermost surface of the cellulose. Thus, a combination of ESCA analysis and high-precision titrations is able to yield a very detailed picture of the effect of digestion conditions on surface properties of cellulose fibers of direct relevance to paper properties.

  19. Misoprostol versus antacid titration for preventing stress ulcers in postoperative surgical ICU patients.

    PubMed Central

    Zinner, M J; Rypins, E B; Martin, L R; Jonasson, O; Hoover, E L; Swab, E A; Fakouhi, T D

    1989-01-01

    Bleeding from gastroduodenal lesions is a potentially life-threatening complication in patients subjected to overwhelming physiologic stress. Titration of gastric contents with antacid was the first prophylactic treatment regimen proved to decrease the incidence of bleeding and remains the standard by which other methods are compared. We designed a prospective double-blind, double-placebo study comparing the effectiveness of antacid titration with fixed doses of a synthetic prostaglandin E1 analog (misoprostol) for preventing stress gastritis and bleeding. To assess the success of each treatment regimen, we did endoscopic examinations before operation, 72 hours after operation, and after the patient had completed the study. A total of 281 patients entered the study (140 misoprostol, 141 antacid). The two groups were comparable with respect to preoperative parameters and type of operation. We found no statistically significant differences between the two treatment groups concerning upper gastrointestinal tract lesions or serious adverse effects. No clinically evident upper gastrointestinal hemorrhage occurred in either group. Mean gastric pH, measured at two-hour intervals during the initial 72 hours, was maintained at 4.0 or higher in both groups. We conclude that fixed-dose misoprostol is as effective as intensive antacid titration in preventing stress ulcers and bleeding in surgical ICU patients. PMID:2510618

  20. Comparison of methods for accurate end-point detection of potentiometric titrations

    NASA Astrophysics Data System (ADS)

    Villela, R. L. A.; Borges, P. P.; Vyskočil, L.

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper.

  1. Economic benefit of back titration in the treatment of hypertension in Jos, Nigeria.

    PubMed

    Okeahialam, Basil N; Adeniyi, Michael A

    2017-01-01

    Treatment of hypertension is expensive and cost is one of the reasons for inadequate blood pressure control. Where there are no social cost cushions, the burden is borne by patients. With pervasive poverty and inadequate control, complications are unchecked. Back titration in appropriate circumstances should, therefore, translate to economic benefit. This is an attempt to compute, in economic terms, the benefit of back titration. Thirty-nine patients who entered an antihypertensive back titration program for 12 months and who had been earlier reported on, form the subject of this study. A survey of the cost of antihypertensives in pharmacy outlets in Jos, Nigeria was undertaken. Regimens of antihypertensives that patients were on at the onset and end of the 12 months of back titration were costed in Nigerian currency and compared. Back titration translated to economic benefit in all patients with a cost reduction varying from 2.3% to 100%. This reflected in reduction in mean daily cost of treatment of N107.09-N54.61. The benefit of antihypertensive back titration apart from psychological relief of lower pill burden and side effect profile is in pharmacoeconomics. This permits greater adherence and prevents morbi-mortality consequences of hypertension. In this study, back titration over 12 months translated to average cost reduction of >50%, making treatment more affordable. In appropriate circumstances, back titration of antihypertensives results in economic relief for patients. This should improve adherence, reduce morbi-mortality and is recommended for wider application.

  2. High mobility group box-1 is phosphorylated by protein kinase C zeta and secreted in colon cancer cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Hanna; Park, Minhee; Shin, Nara

    2012-07-27

    Highlights: Black-Right-Pointing-Pointer Specific enzyme for HMGB1 phosphorylation and its secretion is proposed. Black-Right-Pointing-Pointer Inhibition of PKC-{zeta} leads to significant reduction of the secreted HMGB1. Black-Right-Pointing-Pointer Phosphorylation of specific site of HMGB1 redirects its secretion in cancer cells. Black-Right-Pointing-Pointer Activation of PKC-{zeta} in cancers explains the enhanced HMGB1 secretion. -- Abstract: High mobility group box-1 (HMGB1), a nuclear protein, is overexpressed and secreted in cancer cells. Phosphorylation on two different nuclear localization signal regions are known to be important for the nuclear-to-cytoplasmic transport and secretion of HMGB1. However, little is known about the biochemical mechanism of HMGB1 modifications and its subsequentmore » secretion from cancer cells. To identify the specific enzyme and important sites for HMGB1 phosphorylation, we screened the protein kinase C (PKC) family in a colon cancer cell line (HCT116) for HMGB1 binding by pull-down experiments using a 3XFLAG-HMGB1 construct. Strong interactions between atypical PKCs (PKC-{zeta}, {lambda}, and {iota}) and cytoplasmic HMGB1 were observed in HCT116 cells. We further identified the most critical PKC isotype that regulates HMGB1 secretion is PKC-{zeta} by using PKC inhibitors and siRNA experiments. The serine residues at S39, S53 and S181 of HMGB1 were related to enhancing HMGB1 secretion. We also demonstrated overexpression and activation of PKC-{zeta} in colon cancer tissues. Our findings suggest that PKC-{zeta} is involved in the phosphorylation of HMGB1, and the phosphorylation of specific serine residues in the nuclear localization signal regions is related to enhanced HMGB1 secretion in colon cancer cells.« less

  3. The preparation, surface structure, zeta potential, surface charge density and photocatalytic activity of TiO2 nanostructures of different shapes

    NASA Astrophysics Data System (ADS)

    Grover, Inderpreet Singh; Singh, Satnam; Pal, Bonamali

    2013-09-01

    Titania based nanocatalysts such as sodium titanates of different morphology having superior surface properties are getting wide importance in photocatalysis research. Despite having sodium (Na) contents and its high temperature synthesis (that generally deteriorate the photoreactivity), these Na-titanates often exhibit better photoactivity than P25-TiO2 catalyst. Hence, this work demonstrated the influence of crystal structure, BET surface area, surface charge, zeta potential (ζ) and metal loading on the photocatalytic activity of as-prepared sodium titanate nanotube (TNT) and titania nanorod (TNR). Straw like hollow orthorhombic-TNT (Na2Ti2O5·H2O) particles (W = 9-12 nm and L = 82-115 nm) and rice like pure anatase-TNR particles (W = 8-13 nm and L = 81-134 nm) are obtained by the hydrothermal treatment of P25-TiO2 with NaOH, which in fact, altered the net surface charge of TNT and TNR particles. The observed ζ = -2.82 (P25-TiO2), -13.5 (TNT) and -22.5 mV (TNR) are significantly altered by the Ag and Cu deposition. It has been found here that TNT displayed best photocatalytic activity for the imidacloprid insecticide (C9H10ClN5O2) degradation to CO2 formation under UV irradiation because of its largest surface area 176 m2 g-1 among the catalysts studied.

  4. Density-functional theory of spherical electric double layers and zeta potentials of colloidal particles in restricted-primitive-model electrolyte solutions.

    PubMed

    Yu, Yang-Xin; Wu, Jianzhong; Gao, Guang-Hua

    2004-04-15

    A density-functional theory is proposed to describe the density profiles of small ions around an isolated colloidal particle in the framework of the restricted primitive model where the small ions have uniform size and the solvent is represented by a dielectric continuum. The excess Helmholtz energy functional is derived from a modified fundamental measure theory for the hard-sphere repulsion and a quadratic functional Taylor expansion for the electrostatic interactions. The theoretical predictions are in good agreement with the results from Monte Carlo simulations and from previous investigations using integral-equation theory for the ionic density profiles and the zeta potentials of spherical particles at a variety of solution conditions. Like the integral-equation approaches, the density-functional theory is able to capture the oscillatory density profiles of small ions and the charge inversion (overcharging) phenomena for particles with elevated charge density. In particular, our density-functional theory predicts the formation of a second counterion layer near the surface of highly charged spherical particle. Conversely, the nonlinear Poisson-Boltzmann theory and its variations are unable to represent the oscillatory behavior of small ion distributions and charge inversion. Finally, our density-functional theory predicts charge inversion even in a 1:1 electrolyte solution as long as the salt concentration is sufficiently high. (c) 2004 American Institute of Physics.

  5. 14-3-3 sigma and 14-3-3 zeta plays an opposite role in cell growth inhibition mediated by transforming growth factor-beta 1.

    PubMed

    Hong, Hye-Young; Jeon, Woo-Kwang; Bae, Eun-Jin; Kim, Shin-Tae; Lee, Ho-Jae; Kim, Seong-Jin; Kim, Byung-Chul

    2010-03-01

    The expression of 14-3-3 proteins is dysregulated in various types of cancer. This study was undertaken to investigate the effects of 14-3-3 zeta and 14-3-3 sigma on cell growth inhibition mediated by transforming growth factor-beta 1 (TGF-beta1). Mouse mammary epithelial cells (Eph4) that are transformed with oncogenic c-H-Ras (EpRas) and no longer sensitive to TGF-beta1-mediated growth inhibition displayed increased expression of 14-3-3 zeta and decreased expression of 14-3-3 sigma compared with parental Eph4 cells. Using small interfering RNA-mediated knockdown and overexpression of 14-3-3 sigma or 14-3-3 zeta, we showed that 14-3-3 sigma is required for TGF-beta1-mediated growth inhibition whereas 14-3-3 zeta negatively modulates this growth inhibitory response. Notably, overexpression of 14-3-3 zeta increased the level of Smad3 protein that is phosphorylated at linker regions and cannot mediate the TGF-beta1 growth inhibitory response. Consistent with this finding, mutation of the 14-3-3 zeta phosphorylation sites in Smad3 markedly reduced the 14-3-3 zeta-mediated inhibition of TGF-beta1-induced p15 promoter-reporter activity and cell cycle arrest, suggesting that these residues are critical targets of 14-3-3 zeta in the suppression of TGF-beta1-mediated growth. Taken together, our findings indicate that dysregulation of 14-3-3 sigma or 14-3-3 zeta contributes to TGF-beta1 resistance in cancer cells.

  6. Toxicity and Metabolism of Zeta-Cypermethrin in Field-Collected and Laboratory Strains of the Neotropical Predator Chrysoperla externa Hagen (Neuroptera: Chrysopidae).

    PubMed

    Haramboure, M; Smagghe, G; Niu, J; Christiaens, O; Spanoghe, P; Alzogaray, R A

    2017-06-01

    Resistance to pesticides has been studied in several insect pests, but information on the natural enemies of pests-including the Neotropical predator Chrysoperla externa Hagen (Neuroptera: Chrysopidae), a major biological control agent in South America-is lacking. We report here a comparative study between a field-collected strain of C. externa subjected to monthly sprayings of pyrethroids and neonicotinoids and a laboratory strain without exposure to pesticides. The tolerance of both strains against zeta-cypermethrin was similar, and addition of the synergist piperonyl butoxide increased the toxicity by 30% in both strains. Gas-chromatography analyses and mixed-function-oxidase measurements indicated similar values in both strains and also confirmed the key role of oxidative metabolism in this species. Because C. externa has maintained a tolerance to zeta-cypermethrin without previous pesticide exposure, this species could potentially be mass-reared and released in fields in the presence of pesticide pressure.

  7. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea.

    PubMed

    Levendowski, Daniel J; Morgan, Todd; Westbrook, Philip

    2012-01-01

    Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Significant reductions in the mean overall and supine apnea indexes (p < 0.05), and the overall (p < 0.01) and supine (p < 0.05) apnea/hypopnea indexes were observed for both the titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p < 0.05) and supine (p < 0.01). Patients found their custom appliance was more comfortable than the titration appliance, but preferred the titration appliance to no therapy. The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may

  8. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea

    PubMed Central

    Levendowski, Daniel J.; Morgan, Todd; Westbrook, Philip

    2015-01-01

    Background Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. Objective The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Methods Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Results Significant reductions in the mean overall and supine apnea indexes (p < 0.05), and the overall (p < 0.01) and supine (p < 0.05) apnea/hypopnea indexes were observed for both the titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p < 0.05) and supine (p < 0.01). Patients found their custom appliance was more comfortable than the titration appliance, but preferred the titration appliance to no therapy. Conclusion The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of

  9. Coulometrische titration von hypochloriten und chloraten.

    PubMed

    Gründler, P; Holzapfel, H

    1970-03-01

    Hypochlorite was determined by direct coulometric titration with iron(II) in an acetate buffered solution. Chlorate was titrated with titanium(III) in 2M hydrochloric acid. Amperometric indication with one and two electrodes, respectively, was used. Mixtures of hypochlorites and chlorates, e.g., in industrial electrolytes, may be analysed. On a déterminé l'hypochlorite par titrage coulométrique direct avec le fer(II) dans une solution tamponnée à l'acétate. On a titré le chlorate avec le titane(III) en acide chlorhydrique 2M. On a utilisé l'indication ampérométrique une et deux électrodes respectivement. On peut analyser des mélanges d'hypochlorites et de chlorates, par exemple dans des électrolytes industriels.

  10. The ng_ζ1 toxin of the gonococcal epsilon/zeta toxin/antitoxin system drains precursors for cell wall synthesis.

    PubMed

    Rocker, Andrea; Peschke, Madeleine; Kittilä, Tiia; Sakson, Roman; Brieke, Clara; Meinhart, Anton

    2018-04-27

    Bacterial toxin-antitoxin complexes are emerging as key players modulating bacterial physiology as activation of toxins induces stasis or programmed cell death by interference with vital cellular processes. Zeta toxins, which are prevalent in many bacterial genomes, were shown to interfere with cell wall formation by perturbing peptidoglycan synthesis in Gram-positive bacteria. Here, we characterize the epsilon/zeta toxin-antitoxin (TA) homologue from the Gram-negative pathogen Neisseria gonorrhoeae termed ng_ɛ1 / ng_ζ1. Contrary to previously studied streptococcal epsilon/zeta TA systems, ng_ɛ1 has an epsilon-unrelated fold and ng_ζ1 displays broader substrate specificity and phosphorylates multiple UDP-activated sugars that are precursors of peptidoglycan and lipopolysaccharide synthesis. Moreover, the phosphorylation site is different from the streptococcal zeta toxins, resulting in a different interference with cell wall synthesis. This difference most likely reflects adaptation to the individual cell wall composition of Gram-negative and Gram-positive organisms but also the distinct involvement of cell wall components in virulence.

  11. A model for oxygen conservation associated with titration during pediatric oxygen therapy

    PubMed Central

    Wu, Grace; Wollen, Alec; Himley, Stephen; Austin, Glenn; Delarosa, Jaclyn; Izadnegahdar, Rasa; Ginsburg, Amy Sarah; Zehrung, Darin

    2017-01-01

    Background Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration. Aim To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia. Methods Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration. Results Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3), respectively. For every 100 patients, 44 or 30 kiloliters would be saved—equivalent to 733 or 500 hours at 1 liter per minute. Conclusions Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems. PMID:28234903

  12. A model for oxygen conservation associated with titration during pediatric oxygen therapy.

    PubMed

    Wu, Grace; Wollen, Alec; Himley, Stephen; Austin, Glenn; Delarosa, Jaclyn; Izadnegahdar, Rasa; Ginsburg, Amy Sarah; Zehrung, Darin

    2017-01-01

    Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration. To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia. Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration. Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3), respectively. For every 100 patients, 44 or 30 kiloliters would be saved-equivalent to 733 or 500 hours at 1 liter per minute. Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems.

  13. Effect of surface site interactions on potentiometric titration of hematite (α-Fe2O3) crystal faces.

    PubMed

    Chatman, Shawn; Zarzycki, P; Preočanin, T; Rosso, K M

    2013-02-01

    Time dependent potentiometric pH titrations were used to study the effect of atomic scale surface structure on the protonation behavior of the structurally well-defined hematite/electrolyte interfaces. Our recently proposed thermodynamic model [1,25] was applied to measured acidimetric and alkalimetric titration hysteresis loops, collected from highly organized (001), (012), and (113) crystal face terminations using pH equilibration times ranging from 15 to 30 min. Hysteresis loop areas indicate that (001) faces equilibrate faster than the (012) and (113) faces, consistent with the different expected ensembles of singly-, doubly-, and triply-coordinated surface sites on each face. Strongly non-linear hysteretic pH-potential relationships were found, with slopes exceeding Nernstian, collectively indicating that protonation and deprotonation is much more complex than embodied in present day surface complexation models. The asymmetrical shape of the acidimetric and alkalimetric titration branches were used to illustrate a proposed steric "leaky screen" repulsion/trapping interaction mechanism that stems from high affinity singly-coordinated sites electrostatically and sterically screening lower affinity doubly- and triply-coordinated sites. Our data indicate that site interaction is the dominant phenomenon defining surface potential accumulation behavior on single crystal faces of metal oxide minerals. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Quantitative Analysis of Sulfate in Water by Indirect EDTA Titration

    ERIC Educational Resources Information Center

    Belle-Oudry, Deirdre

    2008-01-01

    The determination of sulfate concentration in water by indirect EDTA titration is an instructive experiment that is easily implemented in an analytical chemistry laboratory course. A water sample is treated with excess barium chloride to precipitate sulfate ions as BaSO[subscript 4](s). The unprecipitated barium ions are then titrated with EDTA.…

  15. Correct titration of non-drugs and some other methodological issues.

    PubMed

    Beneke, M; Rasmus, W; Rød, I S; Fritze, J

    1994-01-01

    Doctors' prescription and dosing behaviour was investigated using data from 9 clinical trials in 550 patients treated with psychotropics. 7 trials were conducted under double- and 2 under single-blind conditions. In 3 of these trials, oral and i.m. preparations were used demanding a double-dummy design. All patients were evaluated on a weekly or 2-week basis using psychopathological rating scales (i.e. Hamilton Anxiety Scale, Hamilton Depression Scale, Clinical Global Impressions, Simpson and Angus EPS). It was found that (a) oral-medication titration was 3- to 4-fold more broad-ranging than i.m. medication titration, (b) oral placebo was titrated to the same extent as the oral investigational drugs, and (c) the titration schedule did not follow protocol requirements. Moreover, the average doses in all drug and placebo groups were the same. Concomitant medication like sleep inducers was found to be more closely related to doctors' habits than to actual medical need. Independent of trial and investigational drug, 10-33% of all patients received additional sleep inducers.

  16. Local zeta factors and geometries under Spec Z

    NASA Astrophysics Data System (ADS)

    Manin, Yu I.

    2016-08-01

    The first part of this note shows that the odd-period polynomial of each Hecke cusp eigenform for the full modular group produces via the Rodriguez-Villegas transform ([1]) a polynomial satisfying the functional equation of zeta type and having non-trivial zeros only in the middle line of its critical strip. The second part discusses the Chebyshev lambda-structure of the polynomial ring as Borger's descent data to \\mathbf{F}_1 and suggests its role in a possible relation of the Γ\\mathbf{R}-factor to 'real geometry over \\mathbf{F}_1' (cf. [2]).

  17. Insights into optimal basal insulin titration in type 2 diabetes: Results of a quantitative survey

    PubMed Central

    Bonnemaire, Mireille; Mical, Marie; Edelman, Steve

    2017-01-01

    Aims Basal insulin (BI) treatment initiation and dose titration in type 2 diabetes (T2DM) are often delayed. Such “clinical inertia” results in poor glycaemic control and high risk of long‐term complications. This survey aimed to determine healthcare professional (HCP) and patient attitudes to BI initiation and titration. Methods An online survey (July–August 2015) including HCPs and patients with T2DM in the USA, France and Germany. Patients were ≥18 years old and had been on BI for 6 to 36 months, or discontinued BI within the previous 12 months. Results Participants comprised 386 HCPs and 318 people with T2DM. While >75% of HCPs reported discussing titration at the initiation visit, only 16% to 28% of patients remembered such discussions, many (32%–42%) were unaware of the need to titrate BI, and only 28% to 39% recalled mention of the time needed to reach glycaemic goals. Most HCPs and patients agreed that more effective support tools to assist BI initiation/titration are needed; patients indicated that provision of such tools would increase confidence in self‐titration. HCPs identified fear of hypoglycaemia, failure to titrate in the absence of symptoms, and low patient motivation as important titration barriers. In contrast, patients identified weight gain, the perception that titration meant worsening disease, frustration over the time to reach HbA1c goals and fear of hypoglycaemia as major factors. Conclusion A disconnect exists between HCP‐ and patient‐perceived barriers to effective BI titration. To optimize titration, strategies should be targeted to improve HCP–patient communication, and provide support and educational tools. PMID:28719066

  18. Protometric thermometric titrations of sparingly soluble compounds in water in the presence of n-octanol.

    PubMed

    Burgot, G; Burgot, J-L

    2002-10-15

    Thermometric titrimetry permits titration of acido-basic compounds in water in the presence of n-octanol. n-Octanol permits the solubilization of protolytes and moreover may also displace the equilibria of the titration reactions. Hydrochlorides of highly insoluble derivatives such as phenothiazine derivatives can be titrated with satisfactory accuracy and precision by sodium hydroxide despite their high pK(a) values. Likewise barbiturate salts can be titrated by hydrochloric acid. In the case of some salts, the methodology may permit the sequential titration of the ion and counter ion. Copyright 2002 Elsevier Science B.V.

  19. The white dwarf companion of the B a 2 star zeta Cap

    NASA Technical Reports Server (NTRS)

    Boehm-Vitense, E.

    1981-01-01

    The Ba II star zeta Cap has a white dwarf companion. Its T (sub eff) is determined to be 22000 K, its mass is approximately one solar mass. The importance of this finding for the explanation of abundance peculiarities is discussed.

  20. Zeta Sperm Selection Improves Pregnancy Rate and Alters Sex Ratio in Male Factor Infertility Patients: A Double-Blind, Randomized Clinical Trial

    PubMed Central

    Nasr Esfahani, Mohammad Hossein; Deemeh, Mohammad Reza; Tavalaee, Marziyeh; Sekhavati, Mohammad Hadi; Gourabi, Hamid

    2016-01-01

    Background Selection of sperm for intra-cytoplasmic sperm injection (ICSI) is usually considered as the ultimate technique to alleviate male-factor infertility. In routine ICSI, selection is based on morphology and viability which does not necessarily preclude the chance injection of DNA-damaged or apoptotic sperm into the oocyte. Sperm with high negative surface electrical charge, named “Zeta potential”, are mature and more likely to have intact chromatin. In addition, X-bearing spermatozoa carry more negative charge. Therefore, we aimed to compare the clinical outcomes of Zeta procedure with routine sperm selection in infertile men candidate for ICSI. Materials and Methods From a total of 203 ICSI cycles studied, 101 cycles were allocated to density gradient centrifugation (DGC)/Zeta group and the remaining 102 were included in the DGC group in this prospective study. Clinical outcomes were com- pared between the two groups. The ratios of Xand Y bearing sperm were assessed by fluorescence in situ hybridization (FISH) and quantitative polymerase chain reaction (qPCR) methods in 17 independent semen samples. Results In the present double-blind randomized clinical trial, a significant increase in top quality embryos and pregnancy rate were observed in DGC/Zeta group compared to DGC group. Moreover, sex ratio (XY/XX) at birth significantly was lower in the DGC/Zeta group compared to DGC group despite similar ratio of X/Y bearings sper- matozoa following Zeta selection. Conclusion Zeta method not only improves the percentage of top embryo quality and pregnancy outcome but also alters the sex ratio compared to the conventional DGC method, despite no significant change in the ratio of Xand Ybearing sperm population (Registration number: IRCT201108047223N1). PMID:27441060

  1. Kinetic Titration Series with Biolayer Interferometry

    PubMed Central

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1–42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations. PMID:25229647

  2. Kinetic titration series with biolayer interferometry.

    PubMed

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1-42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations.

  3. AMDTreat 5.0+ with PHREEQC titration module to compute caustic chemical quantity, effluent quality, and sludge volume

    USGS Publications Warehouse

    Cravotta, Charles A.; Means, Brent P; Arthur, Willam; McKenzie, Robert M; Parkhurst, David L.

    2015-01-01

    Alkaline chemicals are commonly added to discharges from coal mines to increase pH and decrease concentrations of acidity and dissolved aluminum, iron, manganese, and associated metals. The annual cost of chemical treatment depends on the type and quantities of chemicals added and sludge produced. The AMDTreat computer program, initially developed in 2003, is widely used to compute such costs on the basis of the user-specified flow rate and water quality data for the untreated AMD. Although AMDTreat can use results of empirical titration of net-acidic or net-alkaline effluent with caustic chemicals to accurately estimate costs for treatment, such empirical data are rarely available. A titration simulation module using the geochemical program PHREEQC has been incorporated with AMDTreat 5.0+ to improve the capability of AMDTreat to estimate: (1) the quantity and cost of caustic chemicals to attain a target pH, (2) the chemical composition of the treated effluent, and (3) the volume of sludge produced by the treatment. The simulated titration results for selected caustic chemicals (NaOH, CaO, Ca(OH)2, Na2CO3, or NH3) without aeration or with pre-aeration can be compared with or used in place of empirical titration data to estimate chemical quantities, treated effluent composition, sludge volume (precipitated metals plus unreacted chemical), and associated treatment costs. This paper describes the development, evaluation, and potential utilization of the PHREEQC titration module with the new AMDTreat 5.0+ computer program available at http://www.amd.osmre.gov/.

  4. The SimpleMix study with biphasic insulin aspart 30: a randomized controlled trial investigating patient-driven titration versus investigator-driven titration.

    PubMed

    Gao, Yan; Luquez, Cecilia; Lynggaard, Helle; Andersen, Henning; Saboo, Banshi

    2014-12-01

    The study aimed to confirm the efficacy, through non-inferiority, of patient-driven versus investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) in terms of glycemic control assessed by HbA1c change. SimpleMix was a 20 week, open-label, randomized, two-armed, parallel-group, multicenter study in five countries (Argentina, China, India, Poland, and the UK). Patients with type 2 diabetes were randomized into either patient-driven or investigator-driven BIAsp 30 titration groups. Non-inferiority of patient-driven vs. investigator-driven titration based on change in HbA1c from baseline to week 20 could not be demonstrated. Mean (SE) estimated change from baseline to week 20 was -0.72 (0.08)% in the patient-driven group and -0.97 (0.08)% in the investigator-driven group; estimated difference 0.25% (95% CI: 0.04; 0.46). Estimated mean change (SE) in fasting plasma glucose from baseline to week 20 was similar between groups: -0.94 (0.21) mmol/L for patient-driven and -1.07 (0.22) mmol/L for investigator-driven (difference non-significant). Both treatment arms were well tolerated, and hypoglycemic episode rates were similar between groups, with a rate ratio of 0.77 (95% CI: 0.54; 1.09; p = 0.143) for all hypoglycemic episodes and 0.78 (95% CI: 0.42; 1.43; p = 0.417) for nocturnal hypoglycemic episodes. Non-inferiority of patient-driven versus investigator-driven titration with regard to change from baseline to end-of-treatment HbA1c could not be confirmed. It is possible that a clinic visit 12 weeks after intensification of treatment with BIAsp 30 in patients with type 2 diabetes inadequately treated with basal insulin may benefit patient-driven titration of BIAsp 30. A limitation of the study was the relatively small number of patients recruited in each country, which does not allow country-specific analyses to be performed. Overall, treatment with BIAsp 30 was well tolerated in both treatment groups.

  5. Insights into optimal basal insulin titration in type 2 diabetes: Results of a quantitative survey.

    PubMed

    Berard, Lori; Bonnemaire, Mireille; Mical, Marie; Edelman, Steve

    2018-02-01

    Basal insulin (BI) treatment initiation and dose titration in type 2 diabetes (T2DM) are often delayed. Such "clinical inertia" results in poor glycaemic control and high risk of long-term complications. This survey aimed to determine healthcare professional (HCP) and patient attitudes to BI initiation and titration. An online survey (July-August 2015) including HCPs and patients with T2DM in the USA, France and Germany. Patients were ≥18 years old and had been on BI for 6 to 36 months, or discontinued BI within the previous 12 months. Participants comprised 386 HCPs and 318 people with T2DM. While >75% of HCPs reported discussing titration at the initiation visit, only 16% to 28% of patients remembered such discussions, many (32%-42%) were unaware of the need to titrate BI, and only 28% to 39% recalled mention of the time needed to reach glycaemic goals. Most HCPs and patients agreed that more effective support tools to assist BI initiation/titration are needed; patients indicated that provision of such tools would increase confidence in self-titration. HCPs identified fear of hypoglycaemia, failure to titrate in the absence of symptoms, and low patient motivation as important titration barriers. In contrast, patients identified weight gain, the perception that titration meant worsening disease, frustration over the time to reach HbA1c goals and fear of hypoglycaemia as major factors. A disconnect exists between HCP- and patient-perceived barriers to effective BI titration. To optimize titration, strategies should be targeted to improve HCP-patient communication, and provide support and educational tools. © 2017 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.

  6. Clozapine Titration for People in Early Psychosis: A Chart Review and Treatment Guideline.

    PubMed

    Ballon, Jacob S; Ashfaq, Hera; Noordsy, Douglas L

    2018-06-01

    The use of clozapine, particularly in young people, is often limited by early treatment-emergent adverse effects including drowsiness and lethargy. Concerns about adverse effects, medication adherence, and the need for blood monitoring often impede the use of clozapine in this population, leading to repeated trials of less effective medications. Current clozapine dosing recommendations are based on people further in the course of their illness and thus reflect different responsiveness and sensitivities to antipsychotic medication. As such, there is a need for evidence-based guidelines for titration and dosing of clozapine among people in early psychosis. We performed a chart review of 14 people treated with clozapine within our early psychosis team. Data regarding dose titration, response, time to discontinuation, symptom severity, weight gain, and other adverse effects were gathered at clozapine initiation, 3 months, and last available visit on clozapine. People treated with slow titration within their first year of psychosis onset achieved sustained response at very low maintenance doses (mean dose = 81 mg/d, mean duration of treatment = 200 weeks) compared with slow titration with longer duration of illness (mean dose = 350 mg/d, mean duration of treatment = 68 weeks) or standard dose titration in early psychosis (mean dose = 112 mg/d, mean duration of treatment = 38 weeks). The most common adverse effects in all groups were weight gain and sedation, with the groups requiring higher mean doses reporting a broader range of adverse effects. There was no apparent difference in the clinical global impression for severity or improvement between the slow titration and standard titration groups in people with early psychosis. These observations are synthesized into a proposed treatment guideline for use of clozapine among people in early psychosis. We describe development of a slow titration approach to initiating clozapine among people in early psychosis. This

  7. The predictive value of drug-induced sleep endoscopy for CPAP titration in OSA patients.

    PubMed

    Lan, Ming-Chin; Hsu, Yen-Bin; Lan, Ming-Ying; Huang, Yun-Chen; Kao, Ming-Chang; Huang, Tung-Tsun; Chiu, Tsan-Jen; Yang, Mei-Chen

    2017-12-15

    The aim of this study was to identify possible upper airway obstructions causing a higher continuous positive airway pressure (CPAP) titration level, utilizing drug-induced sleep endoscopy (DISE). A total of 76 patients with obstructive sleep apnea (OSA) underwent CPAP titration and DISE. DISE findings were recorded using the VOTE classification system. Polysomnographic (PSG) data, anthropometric variables, and patterns of airway collapse during DISE were analyzed with CPAP titration levels. A significant association was found between the CPAP titration level and BMI, oxygen desaturation index (ODI), apnea-hypopnea index (AHI), and neck circumference (NC) (P < 0.001, P < 0.001, P < 0.001, and P < 0.001, respectively, by Spearman correlation). Patients with concentric collapse of the velum or lateral oropharyngeal collapse were associated with a significantly higher CPAP titration level (P < 0.001 and P = 0.043, respectively, by nonparametric Mann-Whitney U test; P < 0.001 and P = 0.004, respectively, by Spearman correlation). No significant association was found between the CPAP titration level and any other collapse at the tongue base or epiglottis. By analyzing PSG data, anthropometric variables, and DISE results with CPAP titration levels, we can better understand possible mechanisms resulting in a higher CPAP titration level. We believe that the role of DISE can be expanded as a tool to identify the possible anatomical structures that may be corrected by oral appliance therapy or surgical intervention to improve CPAP compliance.

  8. Use of marker ion and cationic surfactant plastic membrane electrode for potentiometric titration of cationic polyelectrolytes.

    PubMed

    Masadome, Takashi; Imato, Toshihiko

    2003-07-04

    A plasticized poly (vinyl chloride) (PVC) membrane electrode sensitive to stearyltrimethylammonium (STA) ion is applied to the determination of cationic polyelectrolytes such as poly (diallyldimethylammonium chloride) (Cat-floc) by potentiometric titration, using a potassium poly (vinyl sulfate) (PVSK) solution as a titrant. The end-point of the titration is detected as the potential change of the plasticized PVC membrane electrode caused by decrease in the concentration of STA ion added to the sample solution as a marker ion due to the ion association reaction between the STA ion and PVSK. The effects of the concentration of STA ion, coexisting electrolytes in the sample solution and pH of the sample on the degree of the potential change at the end-point were examined. A linear relationship between the concentration of cationic polyelectrolyte and the end-point volume of the titrant exists in the concentration range from 2x10(-5) to 4x10(-4) N for Cat-floc, glycol chitosan, and methylglycol chitosan.

  9. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Method A Appendix A to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium ferricyanide titration method is based on method SLM 4/2 described in “Official Method of Analysis,” Society of Leather Trades...

  10. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Method A Appendix A to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., App. A Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium ferricyanide titration method is based on method SLM 4/2 described in “Official Method of Analysis,” Society of...

  11. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Method A Appendix A to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium ferricyanide titration method is based on method SLM 4/2 described in “Official Method of Analysis,” Society of Leather Trades...

  12. End-point detection in potentiometric titration by continuous wavelet transform.

    PubMed

    Jakubowska, Małgorzata; Baś, Bogusław; Kubiak, Władysław W

    2009-10-15

    The aim of this work was construction of the new wavelet function and verification that a continuous wavelet transform with a specially defined dedicated mother wavelet is a useful tool for precise detection of end-point in a potentiometric titration. The proposed algorithm does not require any initial information about the nature or the type of analyte and/or the shape of the titration curve. The signal imperfection, as well as random noise or spikes has no influence on the operation of the procedure. The optimization of the new algorithm was done using simulated curves and next experimental data were considered. In the case of well-shaped and noise-free titration data, the proposed method gives the same accuracy and precision as commonly used algorithms. But, in the case of noisy or badly shaped curves, the presented approach works good (relative error mainly below 2% and coefficients of variability below 5%) while traditional procedures fail. Therefore, the proposed algorithm may be useful in interpretation of the experimental data and also in automation of the typical titration analysis, specially in the case when random noise interfere with analytical signal.

  13. Clinical Outcomes of Continuation of Metformin Titration Instructions with Electronic Prescribing.

    PubMed

    Delate, Thomas; Rader, Nathan; Rawlings, Julia E; Smith, Karen; Herner, Sheryl J

    2015-06-01

    Anecdotal evidence suggests that metformin titration instructions are not being updated and refill requests are approved without modification of the titration instructions such that the titration instructions is continued for patients newly initiated on metformin. This was a retrospective cohort analysis of adult patients who received newly initiated metformin pharmacotherapy. Patients were followed from their initial metformin purchase through two subsequent metformin refill purchases. Outcomes, including the 3-year incidence rate of patients with at least one set of continued titration instructions and proportions of patients with at least one gastrointestinal adverse effect (AE) and those with an elevated glucose measurement at follow-up, were assessed during the time period between patients' second and third metformin purchases. Analyses were performed comparing the exposure (i.e., patients with continued instructions) group to the control (i.e., patients without continued instructions) group. The exposure group had a higher mean age and chronic disease score but lower metformin starting dose than the control group (all p < 0.05). The 3-year incidence rate of patients with at least one continuation of titration instructions was 60.3 % (95 % CI 58.3-62.3). Gastrointestinal AEs were rare with equivalent proportions of patients in each group experiencing an event (p > 0.05). Control patients (48.7 % of patients with a measurement) were more likely to have had poorly controlled glucose than exposure patients (35.7 % of patients with a measurement) (p < 0.001). A high rate of continuation of titration instructions for patients newly initiated on metformin was observed; however, such continuation did not negatively affect clinical outcomes.

  14. Determination of organic bases in non-aqueous solvents by catalytic thermometric titration.

    PubMed

    Vajgand, V J; Kiss, T A; Gaál, F F; Zsigrai, I J

    1968-07-01

    Catalytic thermometric titrations have been developed for bases (brucine, diethylaniline, potassium acetate and triethylamine) in acetic acid by continuous and discontinuous addition of the standard solution and automatic temperature recording. The determination of weak bases, e.g., antipyrine, unsuccessful in acetic acid by catalytic thermometric titration, has been achieved by using nitromethane or acetic anhydride as solvent. Catalytic thermometric titrations were also performed by coulometric generation of hydrogen ions for the determination of micro amounts of weak bases in a mixture of acetic anhyride and acetic acid.

  15. Preparation and characterization of methacrylate hydrogels for zeta potential control

    NASA Technical Reports Server (NTRS)

    Gregonis, D. E.; Ma, S. M.; Vanwagenen, R.; Andrade, J. D.

    1976-01-01

    A technique based on the measurement of streaming potentials has been developed to evaluate the effects of hydrophilic coatings on electroosmotic flow. The apparatus and procedure are described as well as some results concerning the electrokinetic potential of glass capillaries as a function of ionic strength, pH, and temperature. The effect that turbulence and entrance flow conditions have on accurate streaming potential measurements is discussed. Various silane adhesion promoters exhibited only a slight decrease in streaming potential. A coating utilizing a glycidoxy silane base upon which methylcellulose is applied affords a six-fold decrease over uncoated tubes. Hydrophilic methacrylate gels show similar streaming potential behavior, independent of the water content of the gel. By introduction of positive or negative groups into the hydrophilic methacrylate gels, a range of streaming potential values are obtained having absolute positive or negative signs.

  16. Integration and global analysis of isothermal titration calorimetry data for studying macromolecular interactions.

    PubMed

    Brautigam, Chad A; Zhao, Huaying; Vargas, Carolyn; Keller, Sandro; Schuck, Peter

    2016-05-01

    Isothermal titration calorimetry (ITC) is a powerful and widely used method to measure the energetics of macromolecular interactions by recording a thermogram of differential heating power during a titration. However, traditional ITC analysis is limited by stochastic thermogram noise and by the limited information content of a single titration experiment. Here we present a protocol for bias-free thermogram integration based on automated shape analysis of the injection peaks, followed by combination of isotherms from different calorimetric titration experiments into a global analysis, statistical analysis of binding parameters and graphical presentation of the results. This is performed using the integrated public-domain software packages NITPIC, SEDPHAT and GUSSI. The recently developed low-noise thermogram integration approach and global analysis allow for more precise parameter estimates and more reliable quantification of multisite and multicomponent cooperative and competitive interactions. Titration experiments typically take 1-2.5 h each, and global analysis usually takes 10-20 min.

  17. Lacosamide and sodium channel-blocking antiepileptic drug cross-titration against levetiracetam background therapy.

    PubMed

    Baulac, M; Byrnes, W; Williams, P; Borghs, S; Webster, E; De Backer, M; Dedeken, P

    2017-04-01

    To assess prospectively the effectiveness of lacosamide (LCM) added to levetiracetam (LEV) after down-titration of a concomitant sodium channel blocker (SCB) among patients with focal epilepsy not adequately controlled on LEV and SCB. In this open-label trial, LCM was initiated at 100 mg/day and up-titrated to 200-600 mg/day over 9 weeks; SCB down-titration started when LCM dose reached 200 mg/day. Patients remained on stable LCM/LEV doses for 12 weeks' maintenance (21-week treatment period). The primary outcome was retention rate on LCM. Due to recruitment challenges, fewer than the planned 300 patients participated in the trial, resulting in the trial being underpowered. Overall, 120 patients (mean age 39.7 years) started and 93 completed the trial. The most frequently used SCBs were lamotrigine (39.2%), carbamazepine (30.8%) and oxcarbazepine (27.5%). Eighty-four patients adhered to protocol and discontinued their SCB after cross-titration, but there was insufficient evidence for 36 patients. Retention rate was 73.3% (88/120) for all patients and 83.3% (70/84) for those with evidence of SCB discontinuation. Seizure freedom for patients completing maintenance was 14.0% (13/93). Discontinuation due to adverse events (6.7%) and lack of efficacy (3.3%) occurred primarily during cross-titration. Most frequently reported adverse events during treatment were dizziness (23.3%), headache (15.0%) and fatigue (8.3%). In patients with uncontrolled seizures on LEV/SCB, the LCM/LEV combination appeared to be effective and well tolerated. A cross-titration schedule-flexible LCM up-titration, concomitant SCB down-titration and stable background LEV-could present a feasible and practical approach to initiating LCM while minimizing pharmacodynamic interactions with a SCB. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Dose titration of repaglinide in patients with inadequately controlled type 2 diabetes.

    PubMed

    Kølendorf, Klaus; Eriksson, Johan; Birkeland, Kåre I; Kjellström, Thomas; Hreidarsson, Astradur B

    2004-04-01

    A total of 385 drug-therapy naïve patients, with inadequately controlled type 2 diabetes, were randomised into a multinational, parallel-group study to compare two strategies for dose titration of the oral hypoglycaemic agent repaglinide. Patients were allocated to either a fasting blood glucose (FBG) monitoring group with titration target 4.4-6.1 mmol/l or to a post-prandial blood glucose (PPBG) monitoring group with titration target 4.4-8.0 mmol/l. An initial titration period of up to 8 weeks was followed by a 12-week treatment period. Glycaemic control and hypoglycaemic outcomes were compared for the respective groups. HbA(1c) decreased significantly more in the FBG monitoring group by a mean of 1.38% compared to the PPBG group by a mean of 1.22% (P=0.03). The glycaemic control targets were met by fewer patients in the FBG group than in the PPBG group (57% versus 86% (P<0.001)) despite a higher mean dose of repaglinide in the FBG group. The within-patient blood glucose variability was significantly lower in the FBG group than in the PPBG group (P<0.001). In conclusion, repaglinide lowered the HbA(1c) effectively and safely in both groups and self-monitored FBG is a suitable parameter for titration of repaglinide. Whether a lower PPBG target might be as good a guide as FBG for titration of repaglinide should be addressed in a future study.

  19. On small values of the Riemann zeta-function at Gram points

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korolev, M A

    In this paper, we prove the existence of a large set of Gram points t{sub n} such that the values ζ(0.5+it{sub n}) are 'anomalously' close to zero. A lower bound for the negative 'discrete' moment of the Riemann zeta-function on the critical line is also given. Bibliography: 13 titles.

  20. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects.

    PubMed

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-03-01

    Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1-phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Fifty-six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25-10 mg over 9-10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1-12 vs. the non-titration regimen on day 1 for HR effects (P < 0.0001). On day 1, the geometric mean ratio of the fraction from the previous day in minimum daily HR between DT1 and non-titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P < 0.05) with significant differences noted through to day 12. Non-titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3-7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min⁻¹; P ≤ 0.0001). From days 9-12, HRs in both titration regimens were comparable with placebo. Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. © 2012 Novartis Institutes for BioMedical Research (NIBIR). British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  1. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects

    PubMed Central

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-01-01

    Aim Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1‐phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Methods Fifty‐six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25–10 mg over 9–10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Results Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1–12 vs. the non‐titration regimen on day 1 for HR effects (P < 0.0001). On day 1, the geometric mean ratio of the fraction from the previous day in minimum daily HR between DT1 and non‐titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P < 0.05) with significant differences noted through to day 12. Non‐titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3–7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min−1; P ≤ 0.0001). From days 9–12, HRs in both titration regimens were comparable with placebo. Conclusion Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. PMID:22845008

  2. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    PubMed Central

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R 2 = 0.997). PMID:22567558

  3. Randomized Trial of Long-Acting Insulin Glargine Titration Web Tool (LTHome) Versus Enhanced Usual Therapy of Glargine Titration (INNOVATE Trial).

    PubMed

    Bajaj, Harpreet S; Venn, Karri; Ye, Chenglin; Aronson, Ronnie

    2016-10-01

    Basal insulin titration in the real world is often unsuccessful. LTHome, a web tool, applies a rules engine-based algorithm providing insulin titration advice directly to the patient. This pilot, randomized trial evaluates basal insulin glargine titration by LTHome compared to enhanced usual therapy ([EUT]-diabetes education program) over 12 weeks. Important inclusion criteria: 18-75 years, type 2 diabetes, computer literacy, and HbA1c >7.0%. Trial protocol was approved by ethics board. We randomized 139 subjects. The achievement of primary composite outcome (four out of seven fasting plasma glucose [FPG] within 5-7.2 mmol/L + mean for three consecutive FPG within 5-7.2 mmol/L + no severe hypoglycemia) was 15% in LTHome versus 41% in EUT (noninferiority not met, P-value = 0.92). Other outcomes were similar between the LTHome and EUT arms: alternate composite outcome achievement (last five FPG mean within the range of 5-7.2 mmol/L + no hypoglycemia, 47% and 51%, P = 0.73); A1c reduction (-1.0% and -1.1%, P = 0.66); proportion achieving A1c ≤7% (14% and 20%, P = 0.36); and hypoglycemia incidence (31% and 37%, P = 0.4), respectively. Patient satisfaction score improvements were greater in LTHome versus EUT (change in fear of hypoglycemia score P = 0.04 and change in diabetes distress score P = 0.04). The mean number of additional healthcare provider visits was 0.13 for LTHome and 1.22 for EUT (P < 0.01). INNOVATE trial suggests clinical utility of LTHome compared to EUT in real-life settings. Further research is needed to evaluate the efficacy and safety of automated insulin titration algorithms.

  4. IUE observations of the atmospheric eclipsing binary system Zeta Aurigae

    NASA Technical Reports Server (NTRS)

    Champman, R. D.

    1980-01-01

    IUE observations of the eclipsing binary system Zeta Aurigae made prior to and during the eclipse of the relatively small B8 V star by the cool supergiant star (spectral type K2 II) are reported. Spectral lines produced by the absorption of B star radiation in the atmosphere of the K star during eclipse can be used as a probe of the extended K star atmosphere, due to the negligible cool star continuum in the 1200-3200 A region. Spectra taken prior to eclipse are found to be similar to those of the single B8 V star 64 Ori, with the exception of very strong multi-component absorption lines of Si II, Si IV, C IV and the Mg resonance doublet with strong P Cygni profiles, indicating a double shell. Absorption lines including those corresponding to Al II, Al III, Cr II, Mn II, Fe II, Ni II and Ca II are observed to increase in strength and number as the eclipse progresses, with high-ionization-potential lines formed far from the K star, possibly in a shock wave, and low-ionization potential lines, formed in cool plasma, probably a cool wind, nearer to the K star. Finally, an emission-line spectra with lines corresponding to those previously observed in absorption is noted at the time the B-star continuum had disappeared.

  5. Safety and tolerability of different titration rates of retigabine (ezogabine) in patients with partial-onset seizures.

    PubMed

    Biton, Victor; Gil-Nagel, Antonio; Brodie, Martin J; Derossett, Sarah E; Nohria, Virinder

    2013-11-01

    Retigabine (RTG; international nonproprietary name)/ezogabine (EZG; US adopted name) is an antiepileptic drug (AED) that prolongs neuronal voltage-gated potassium-channel KCNQ2-5 (Kv 7.2-7.5) opening. This double-blind study evaluated different RTG/EZG dose-titration rates. Patients (N=73) with partial-onset seizures receiving concomitant AEDs were randomized to one of three titration groups, all of which were initiated at RTG/EZG 300mg/day divided into three equal doses. Fast-, medium-, and slow-titration groups received dose increments of 150mg/day every 2, 4, and 7 days, respectively, achieving the target dose of 1200mg/day after 13, 25, and 43 days, respectively. Safety assessments were performed throughout. Discontinuation rates due to treatment-emergent adverse events (TEAEs) were numerically higher in the fast- (10/23) and medium- (7/22) titration groups than in the slow-titration group (3/23) but statistical significance was achieved only for the high-titration group compared with the low-titration group (p=0.024). Stratified analysis, with concomitant AEDs divided into enzyme inducers (carbamazepine, phenytoin, oxcarbazepine) or noninducers, showed that the risk of discontinuation due primarily to TEAEs was significantly higher in the fast- (p=0.010) but not in the medium-titration group (p=0.078) when compared with the slow-titration group. Overall, the slow-titration rate appeared to be best tolerated and was used in further efficacy and safety studies with RTG/EZG. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Evaluation of modified boehm titration methods for use with biochars.

    PubMed

    Fidel, Rivka B; Laird, David A; Thompson, Michael L

    2013-11-01

    The Boehm titration, originally developed to quantify organic functional groups of carbon blacks and activated carbons in discrete pK ranges, has received growing attention for analyzing biochar. However, properties that distinguish biochar from carbon black and activated carbon, including greater carbon solubility and higher ash content, may render the original Boehm titration method unreliable for use with biochars. Here we use seven biochars and one reference carbon black to evaluate three Boehm titration methods that use (i) acidification followed by sparging (sparge method), (ii) centrifugation after treatment with BaCl (barium method), and (iii) a solid-phase extraction cartridge followed by acidification and sparging (cartridge method) to remove carbonates and dissolved organic compounds (DOC) from the Boehm extracts before titration. Our results for the various combinations of Boehm reactants and methods indicate that no one method was free of bias for all three Boehm reactants and that the cartridge method showed evidence of bias for all pK ranges. By process of elimination, we found that a combination of the sparge method for quantifying functional groups in the lowest pK range (∼5 to 6.4), and the barium method for quantifying functional groups in the higher pK ranges (∼6.4 to 10.3 and ∼10.3 to 13) to be free of evidence for bias. We caution, however, that further testing is needed and that all Boehm titration results for biochars should be considered suspect unless efforts were undertaken to remove ash and prevent interference from DOC. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  7. A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations

    ERIC Educational Resources Information Center

    Dahm, Christopher E.; Hall, James W.; Mattioni, Brian E.

    2004-01-01

    A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations,…

  8. Direct Sensing of Total Acidity by Chronopotentiometric Flash Titrations at Polymer Membrane Ion-Selective Electrodes

    PubMed Central

    Gemene, Kebede L.; Bakker, Eric

    2008-01-01

    Polymer membrane ion-selective electrodes containing lipophilic ionophores are traditionally interrogated by zero current potentiometry, which, ideally, gives information on the sample activity of ionic species. It is shown here that a discrete cathodic current pulse across an H+-selective polymeric membrane doped with the ionophore ETH 5294 may be used for the chronopotentiometric detection of pH in well buffered samples. However, a reduction in the buffer capacity leads to large deviations from the expected Nernstian response slope. This is explained by the local depletion of hydrogen ions at the sample-membrane interface as a result of the galvanostatically imposed ion flux in direction of the membrane. This depletion is found to be a function of the total acidity of the sample and can be directly monitored chronopotentiometrically in a flash titration experiment. The subsequent application of a baseline potential pulse reverses the extraction process of the current pulse, allowing one to interrogate the sample with minimal perturbation. In one protocol, total acidity is found to be proportional to the magnitude of applied current at the flash titration endpoint. More conveniently, the square root of the flash titration endpoint time observed at a fixed applied current is a linear function of the total acid concentration. This suggests that it is possible to perform rapid localized pH titrations at ion-selective electrodes without the need for volumetric titrimetry. The technique is explored here for acetic acid, MES and citric acid with promising results. Polymeric membrane electrodes on the basis of poly(vinyl chloride) plasticized with o-nitrophenyloctylether in a 1:2 mass ratio may be used for the detection of acids of up to ca. 1 mM concentration, with flash titration times on the order of a few seconds. Possible limitations of the technique are discussed, including variations of the acid diffusion coefficients and influence of electrical migration. PMID

  9. Home blood pressure monitoring and self-titration of antihypertensive medications: Proposed patient selection criteria.

    PubMed

    Hill, James R

    2016-05-01

    Recent studies have demonstrated that home blood pressure monitoring (HBPM), coupled with self-titration of medications is a viable intervention to control hypertension. There are currently no established criteria to evaluate patients for inclusion in such a program. The purpose of this discussion is to propose criteria for determining if a patient is appropriate to participate in a program of HBPM and self-titration. Inclusion criteria for two self-titration trials were examined, and additional factors in clinical practice were identified and discussed. Additional selection criteria were proposed to support the decision to enroll a patient in an antihypertensive self-titration program. Inclusion criteria from self-titration trials provide a reasonable starting point for choosing appropriate patients in clinical practice, but additional research is necessary. Adaptation of these criteria and consideration of the identified factors can be used to develop decision support instruments. Such instruments should be evaluated for effectiveness and reliability prior to use in clinical practice. HBPM combined with self-titration is an effective patient-centered approach for hypertension management. Decision support instruments to determine appropriate patients are necessary for safe and effective use in clinical practice. ©2015 American Association of Nurse Practitioners.

  10. Concentration-related response potentiometric titrations to study the interaction of small molecules with large biomolecules.

    PubMed

    Hamidi-Asl, Ezat; Daems, Devin; De Wael, Karolien; Van Camp, Guy; Nagels, Luc J

    2014-12-16

    In the present paper, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small-molecule interactions is reported. This approach is fast, sensitive, reproducible, and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small-molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed into a concentration-related signal over the entire concentration interval, also at low concentrations, where the millivolt (y-axis) versus log canalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anticocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis(4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using surface plasmon resonance. The potentiometric titration approach called "concentration-related response potentiometry" is used to study molecular interaction for seven macromolecular target molecules and four small-molecule ligands.

  11. Virtual Titrator: A Student-Oriented Instrument.

    ERIC Educational Resources Information Center

    Ritter, David; Johnson, Michael

    1997-01-01

    Describes a titrator system, constructed from a computer-interfaced pH-meter, that was designed to increase student involvement in the process. Combines automatic data collection with real-time graphical display and interactive controls to focus attention on the process rather than on bits of data. Improves understanding of concepts and…

  12. Titration Calculations with Computer Algebra Software

    ERIC Educational Resources Information Center

    Lachance, Russ; Biaglow, Andrew

    2012-01-01

    This article examines the symbolic algebraic solution of the titration equations for a diprotic acid, as obtained using "Mathematica," "Maple," and "Mathcad." The equilibrium and conservation equations are solved symbolically by the programs to eliminate the approximations that normally would be performed by the student. Of the three programs,…

  13. Radio and submillimetre observations of wind structure in zeta Puppis

    NASA Astrophysics Data System (ADS)

    Blomme, R.; van de Steene, G. C.; Prinja, R. K.; Runacres, M. C.; Clark, J. S.

    2003-09-01

    We present radio and submillimetre observations of the O4I(n)f star zeta Pup, and discuss structure in the outer region of its wind ( ~ 10-100 R_*). The properties of bremsstrahlung, the dominant emission process at these wavelengths, make it sensitive to structure and allow us to study how the amount of structure changes in the wind by comparing the fluxes at different wavelengths. Possible forms of structure at these distances include Corotating Interaction Regions (CIRs), stochastic clumping, a disk or a polar enhancement. As the CIRs are azimuthally asymmetric, they should result in variability at submillimetre or radio wavelengths. To look for this variability, we acquired 3.6 and 6 cm observations with the Australia Telescope Compact Array (ATCA), covering about two rotational periods of the star. We supplemented these with archive observations from the NRAO Very Large Array (VLA), which cover a much longer time scale. We did not find variability at more than the +/-20% level. The long integration time does allow an accurate determination of the fluxes at 3.6 and 6 cm. Converting these fluxes into a mass loss rate, we find dot {M} = 3.5 x 10-6 Msun/yr. This value confirms the significant discrepancy with the mass loss rate derived from the Hα profile, making zeta Pup an exception to the usually good agreement between the Hα and radio mass loss rates. To study the run of structure as a function of distance, we supplemented the ATCA data by observing zeta Pup at 850 mu m with the James Clerk Maxwell Telescope (JCMT) and at 20 cm with the VLA. A smooth wind model shows that the millimetre fluxes are too high compared to the radio fluxes. While recombination of helium in the outer wind cannot be discounted as an explanation, the wealth of evidence for structure strongly suggests this as the explanation for the discrepancy. Model calculations show that the structure needs to be present in the inner ~ 70 R_* of the wind, but that it decays significantly, or maybe

  14. Thermometric titration of cadmium with sodium diethyldithiocarbamate, with oxidation by hydrogen peroxide as indicator reaction.

    PubMed

    Hattori, T; Yoshida, H

    1987-08-01

    A new method of end-point indication is described for thermometric titration of cadmium with sodium diethyldithiocarbamate (DDTC). It is based on the redox reaction between hydrogen peroxide added to the system before titration, and the first excess of DDTC. Amounts of cadmium in the range 10-50 mumoles are titrated within 1% error.

  15. Process monitored spectrophotometric titration coupled with chemometrics for simultaneous determination of mixtures of weak acids.

    PubMed

    Liao, Lifu; Yang, Jing; Yuan, Jintao

    2007-05-15

    A new spectrophotometric titration method coupled with chemometrics for the simultaneous determination of mixtures of weak acids has been developed. In this method, the titrant is a mixture of sodium hydroxide and an acid-base indicator, and the indicator is used to monitor the titration process. In a process of titration, both the added volume of titrant and the solution acidity at each titration point can be obtained simultaneously from an absorption spectrum by least square algorithm, and then the concentration of each component in the mixture can be obtained from the titration curves by principal component regression. The method only needs the information of absorbance spectra to obtain the analytical results, and is free of volumetric measurements. The analyses are independent of titration end point and do not need the accurate values of dissociation constants of the indicator and the acids. The method has been applied to the simultaneous determination of the mixtures of benzoic acid and salicylic acid, and the mixtures of phenol, o-chlorophenol and p-chlorophenol with satisfactory results.

  16. Asphalt compatibility testing using the automated Heithaus titration test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pauli, A.T.

    1996-12-31

    The Heithaus titration test or variations of the test have been used for over 35 years to predict compatibilities of blends of asphalts from different crude sources. Asphalt compatibility is determined from three calculated parameters that measure the state of peptization of an asphalt or asphalt blend. The parameter p{sub a} is a measure of the peptizability of the asphaltenes. The parameter p{sub a} is a measure of the peptizing power of the maltenes, and the parameter P, derived from p{sub a} and p{sub o} values, is a measure of the overall state of peptization of the asphalt or asphaltmore » blend. In Heithaus original procedure, samples of asphalt were dissolved in toluene and titrated with n-heptane in order to initiate flocculation. The onset of flocculation was detected either by photography or by spotting a filter paper with a small amount of the titrated solution. Recently, an {open_quotes}automated{close_quotes} procedure, after Hotier and Robin, has been developed for use with asphalt. In the automated method UV-visible spectrophotometric detection measures the onset of flocculation as a peak with the percent transmittance plotted as a function of the volume of titrating solvent added to a solution of asphalt. The automated procedure has proven to be less operator dependent and much faster than the original Heithaus procedure. Results from the automated procedure show the data to be consistent with results from the original, {open_quotes}classical{close_quotes} Heithaus procedure.« less

  17. Accuracy and precision of protein-ligand interaction kinetics determined from chemical shift titrations.

    PubMed

    Markin, Craig J; Spyracopoulos, Leo

    2012-12-01

    NMR-monitored chemical shift titrations for the study of weak protein-ligand interactions represent a rich source of information regarding thermodynamic parameters such as dissociation constants (K ( D )) in the micro- to millimolar range, populations for the free and ligand-bound states, and the kinetics of interconversion between states, which are typically within the fast exchange regime on the NMR timescale. We recently developed two chemical shift titration methods wherein co-variation of the total protein and ligand concentrations gives increased precision for the K ( D ) value of a 1:1 protein-ligand interaction (Markin and Spyracopoulos in J Biomol NMR 53: 125-138, 2012). In this study, we demonstrate that classical line shape analysis applied to a single set of (1)H-(15)N 2D HSQC NMR spectra acquired using precise protein-ligand chemical shift titration methods we developed, produces accurate and precise kinetic parameters such as the off-rate (k ( off )). For experimentally determined kinetics in the fast exchange regime on the NMR timescale, k ( off ) ~ 3,000 s(-1) in this work, the accuracy of classical line shape analysis was determined to be better than 5 % by conducting quantum mechanical NMR simulations of the chemical shift titration methods with the magnetic resonance toolkit GAMMA. Using Monte Carlo simulations, the experimental precision for k ( off ) from line shape analysis of NMR spectra was determined to be 13 %, in agreement with the theoretical precision of 12 % from line shape analysis of the GAMMA simulations in the presence of noise and protein concentration errors. In addition, GAMMA simulations were employed to demonstrate that line shape analysis has the potential to provide reasonably accurate and precise k ( off ) values over a wide range, from 100 to 15,000 s(-1). The validity of line shape analysis for k ( off ) values approaching intermediate exchange (~100 s(-1)), may be facilitated by more accurate K ( D ) measurements

  18. Number of independent parameters in the potentiometric titration of humic substances.

    PubMed

    Lenoir, Thomas; Manceau, Alain

    2010-03-16

    With the advent of high-precision automatic titrators operating in pH stat mode, measuring the mass balance of protons in solid-solution mixtures against the pH of natural and synthetic polyelectrolytes is now routine. However, titration curves of complex molecules typically lack obvious inflection points, which complicates their analysis despite the high-precision measurements. The calculation of site densities and median proton affinity constants (pK) from such data can lead to considerable covariance between fit parameters. Knowing the number of independent parameters that can be freely varied during the least-squares minimization of a model fit to titration data is necessary to improve the model's applicability. This number was calculated for natural organic matter by applying principal component analysis (PCA) to a reference data set of 47 independent titration curves from fulvic and humic acids measured at I = 0.1 M. The complete data set was reconstructed statistically from pH 3.5 to 9.8 with only six parameters, compared to seven or eight generally adjusted with common semi-empirical speciation models for organic matter, and explains correlations that occur with the higher number of parameters. Existing proton-binding models are not necessarily overparametrized, but instead titration data lack the sensitivity needed to quantify the full set of binding properties of humic materials. Model-independent conditional pK values can be obtained directly from the derivative of titration data, and this approach is the most conservative. The apparent proton-binding constants of the 23 fulvic acids (FA) and 24 humic acids (HA) derived from a high-quality polynomial parametrization of the data set are pK(H,COOH)(FA) = 4.18 +/- 0.21, pK(H,Ph-OH)(FA) = 9.29 +/- 0.33, pK(H,COOH)(HA) = 4.49 +/- 0.18, and pK(H,Ph-OH)(HA) = 9.29 +/- 0.38. Their values at other ionic strengths are more reliably calculated with the empirical Davies equation than any existing model fit.

  19. Determination of quaternary ammonium compounds by potentiometric titration with an ionic surfactant electrode: single-laboratory validation.

    PubMed

    Price, Randi; Wan, Ping

    2010-01-01

    A potentiometric titration for determining the quaternary ammonium compounds (QAC) commonly found in antimicrobial products was validated by a single laboratory. Traditionally, QACs were determined by using a biphasic (chloroform and water) manual titration procedure. Because of safety considerations regarding chloroform, as well as the subjectivity of color indicator-based manual titration determinations, an automatic potentiometric titration procedure was tested with quaternary nitrogen product formulations. By using the Metrohm Titrando system coupled with an ionic surfactant electrode and an Ag/AgCl reference electrode, titrations were performed with various QAC-containing formulation products/matrixes; a standard sodium lauryl sulfate solution was used as the titrant. Results for the products tested are sufficiently reproducible and accurate for the purpose of regulatory product enforcement. The robustness of the method was measured by varying pH levels, as well as by comparing buffered versus unbuffered titration systems. A quantitation range of 1-1000 ppm quaternary nitrogen was established. Eight commercially available antimicrobial products covering a variety of matrixes were assayed; the results obtained were comparable to those obtained by the manual titration method. Recoveries of 94 to 104% were obtained for spiked samples.

  20. Determination of Titratable Acidity in Wine Using Potentiometric, Conductometric, and Photometric Methods

    ERIC Educational Resources Information Center

    Volmer, Dietrich A.; Curbani, Luana; Parker, Timothy A.; Garcia, Jennifer; Schultz, Linda D.; Borges, Endler Marcel

    2017-01-01

    This experiment describes a simple protocol for teaching acid-base titrations using potentiometry, conductivity, and/or photometry to determine end points without an added indicator. The chosen example examines the titratable acidity of a red wine with NaOH. Wines contain anthocyanins, the colors of which change with pH. Importantly, at the…

  1. A variable pressure method for characterizing nanoparticle surface charge using pore sensors.

    PubMed

    Vogel, Robert; Anderson, Will; Eldridge, James; Glossop, Ben; Willmott, Geoff

    2012-04-03

    A novel method using resistive pulse sensors for electrokinetic surface charge measurements of nanoparticles is presented. This method involves recording the particle blockade rate while the pressure applied across a pore sensor is varied. This applied pressure acts in a direction which opposes transport due to the combination of electro-osmosis, electrophoresis, and inherent pressure. The blockade rate reaches a minimum when the velocity of nanoparticles in the vicinity of the pore approaches zero, and the forces on typical nanoparticles are in equilibrium. The pressure applied at this minimum rate can be used to calculate the zeta potential of the nanoparticles. The efficacy of this variable pressure method was demonstrated for a range of carboxylated 200 nm polystyrene nanoparticles with different surface charge densities. Results were of the same order as phase analysis light scattering (PALS) measurements. Unlike PALS results, the sequence of increasing zeta potential for different particle types agreed with conductometric titration.

  2. Boundary Conditions for the Maintenance of Memory by PKM[zeta] in Neocortex

    ERIC Educational Resources Information Center

    Shema, Reul; Hazvi, Shoshi; Sacktor, Todd C.; Dudai, Yadin

    2009-01-01

    We report here that ZIP, a selective inhibitor of the atypical protein kinase C isoform PKM[zeta], abolishes very long-term conditioned taste aversion (CTA) associations in the insular cortex of the behaving rat, at least 3 mo after encoding. The effect of ZIP is not replicated by a general serine/threonine protein kinase inhibitor that is…

  3. Synthesis and characterization of N-(2-hydroxy)propyl-3-trimethyl ammonium chitosan chloride for potential application in gene delivery.

    PubMed

    Xiao, Bo; Wan, Ying; Wang, Xiaoyu; Zha, Qichen; Liu, Haoming; Qiu, Zhiye; Zhang, Shengmin

    2012-03-01

    A series of N-(2-hydroxy)propyl-3-trimethyl ammonium chitosan chloride (HTCC) samples with various degrees of quaternization ranging from 12.4 to 43.7% was synthesized. The structures and properties of HTCC were investigated by FT-IR, (1)H NMR, conductometric titration and XRD analysis. It was found that HTCC had a more amorphous structure than chitosan. HTCC samples showed significantly lower cytotoxicity than polyethyleneimine in HepG2 and HeLa cell lines. The samples spontaneously formed complexes with pGL3 luciferase plasmid. These complexes had desirable particle sizes (160-300 nm) and zeta potentials (10.8-18.7 mV) when the weight ratios of HTCC to plasmid altered in the range of 3:1-20:1. In vitro gene transfection results indicated that HTCC had significantly high transfection efficiency compared with chitosan for delivering pGL3 luciferase plasmid to HeLa cells. The results suggest that HTCC could be a promising non-viral vector for safe and efficient DNA delivery. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Value of routine investigations to predict loop diuretic down-titration success in stable heart failure.

    PubMed

    Martens, Pieter; Verbrugge, Frederik H; Boonen, Levinia; Nijst, Petra; Dupont, Matthias; Mullens, Wilfried

    2018-01-01

    Guidelines advocate down-titration of loop diuretics in chronic heart failure (CHF) when patients have no signs of volume overload. Limited data are available on the expected success rate of this practice or how routine diagnostic tests might help steering this process. Fifty ambulatory CHF-patients on stable neurohumoral blocker/diuretic therapy for at least 3months without any clinical sign of volume overload were prospectively included to undergo loop diuretic down-titration. All patients underwent a similar pre-down-titration evaluation consisting of a dyspnea scoring, physical examination, transthoracic echocardiography (diastolic function, right ventricular function, cardiac filling pressures and valvular disease), blood sample (serum creatinine, plasma NT-pro-BNP and neurohormones). Loop diuretic maintenance dose was subsequently reduced by 50% or stopped if dose was ≤40mg furosemide equivalents. Successful down-titration was defined as a persistent dose reduction after 30days without weight increase >1.5kg or new-onset symptoms of worsening heart failure. At 30-day follow-up, down-titration was successful in 62% (n=31). In 12/19 patients exhibiting down-titration failure, this occurred within the first week. Physical examination, transthoracic echocardiography and laboratory analysis had limited predictive capability to detect patients with down-titration success/failure (positive likelihood-ratios below 1.5, or area under the curve [AUC] non-statically different from AUC=0.5). Loop diuretic down-titration is feasible in a majority of stable CHF patients in which the treating clinician felt continuation of loops was unnecessary to sustain euvolemia. Importantly, routine diagnostics which suggest euvolemia, have limited diagnostic impact on the post-test probability. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Ascorbic Acid as a Standard for Iodometric Titrations. An Analytical Experiment for General Chemistry

    NASA Astrophysics Data System (ADS)

    Silva, Cesar R.; Simoni, Jose A.; Collins, Carol H.; Volpe, Pedro L. O.

    1999-10-01

    Ascorbic acid is suggested as the weighable compound for the standardization of iodine solutions in an analytical experiment in general chemistry. The experiment involves an iodometric titration in which iodine reacts with ascorbic acid, oxidizing it to dehydroascorbic acid. The redox titration endpoint is determined by the first iodine excess that is complexed with starch, giving a deep blue-violet color. The results of the titration of iodine solution using ascorbic acid as a calibration standard were compared with the results acquired by the classic method using a standardized solution of sodium thiosulfate. The standardization of the iodine solution using ascorbic acid was accurate and precise, with the advantages of saving time and avoiding mistakes due to solution preparation. The colorless ascorbic acid solution gives a very clear and sharp titration end point with starch. It was shown by thermogravimetric analysis that ascorbic acid can be dried at 393 K for 2 h without decomposition. This experiment allows general chemistry students to perform an iodometric titration during a single laboratory period, determining with precision the content of vitamin C in pharmaceutical formulations.

  6. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level.

    PubMed

    Sahoo, P; Ananthanarayanan, R; Malathi, N; Rajiniganth, M P; Murali, N; Swaminathan, P

    2010-06-11

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 microg L(-1) levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L(-1) levels, with modification in methodology for accurate detection of end point even at 10.0 microg L(-1) levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 microg L(-1) O(2). Finally, several water samples containing dissolved oxygen from mg L(-1) to microg L(-1) levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 microg L(-1) O(2) level is 0.14 (n=5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 microg L(-1) levels. Copyright 2010 Elsevier B.V. All rights reserved.

  7. Dopant titrating ion mobility spectrometry for trace exhaled nitric oxide detection.

    PubMed

    Peng, Liying; Hua, Lei; Li, Enyou; Wang, Weiguo; Zhou, Qinghua; Wang, Xin; Wang, Changsong; Li, Jinghua; Li, Haiyang

    2015-01-05

    Ion mobility spectrometry (IMS) is a promising non-invasive tool for the analysis of exhaled gas and exhaled nitric oxide (NO), a biomarker for diagnosis of respiratory diseases. However, the high moisture in exhaled gas always brings about extra overlapping ion peaks and results in poor identification ability. In this paper, p-benzoquinone (PBQ) was introduced into IMS to eliminate the interference of overlapping ion peaks and realize the selective identification of NO. The overlapping ions caused by moisture were titrated by PBQ and then converted to hydrated PBQ anions (C6H4[Formula: see text](H2O)n). The NO concentration could be determined by quantifying gas phase hydrated nitrite anions (N[Formula: see text](H2O)n), product ions of NO. Under optimized conditions, a limit of detection (LOD) of about 1.4 ppbv and a linear range of 10-200 ppbv were obtained for NO even in 100% relative humidity (RH) purified air. Furthermore, this established method was applied to measure hourly the exhaled NO of eight healthy volunteers, and real-time monitoring the exhaled NO of an esophageal carcinoma patient during radical surgery. These results revealed the potential of the current dopant titrating IMS method in the measurement of exhaled NO for medical disease diagnosis.

  8. Development of a Platform to Enable Fully Automated Cross-Titration Experiments.

    PubMed

    Cassaday, Jason; Finley, Michael; Squadroni, Brian; Jezequel-Sur, Sylvie; Rauch, Albert; Gajera, Bharti; Uebele, Victor; Hermes, Jeffrey; Zuck, Paul

    2017-04-01

    In the triage of hits from a high-throughput screening campaign or during the optimization of a lead compound, it is relatively routine to test compounds at multiple concentrations to determine potency and maximal effect. Additional follow-up experiments, such as agonist shift, can be quite valuable in ascertaining compound mechanism of action (MOA). However, these experiments require cross-titration of a test compound with the activating ligand of the receptor requiring 100-200 data points, severely limiting the number tested in MOA assays in a screening triage. We describe a process to enhance the throughput of such cross-titration experiments through the integration of Hewlett Packard's D300 digital dispenser onto one of our robotics platforms to enable on-the-fly cross-titration of compounds in a 1536-well plate format. The process handles all the compound management and data tracking, as well as the biological assay. The process relies heavily on in-house-built software and hardware, and uses our proprietary control software for the platform. Using this system, we were able to automate the cross-titration of compounds for both positive and negative allosteric modulators of two different G protein-coupled receptors (GPCRs) using two distinct assay detection formats, IP1 and Ca 2+ detection, on nearly 100 compounds for each target.

  9. Effect of Spatial Titration on Task Performance

    ERIC Educational Resources Information Center

    Glowacki, Lawrence

    1976-01-01

    A reinforcement schedule and spatial titration method were used to determine task-reinforcement area separation most preferred and effective in two third-grade boys. Errors in task performance decreased task-reinforcement area separation, while correct responses in task performance increased task-reinforcement area separation. (Author)

  10. Determination of polyhexamethylene biguanide hydrochloride using photometric colloidal titration with crystal violet as a color indicator.

    PubMed

    Masadome, Takashi; Miyanishi, Takaaki; Watanabe, Keita; Ueda, Hiroshi; Hattori, Toshiaki

    2011-01-01

    A solution of polyhexamethylene biguanide hydrochloride (PHMB-HCl) was titrated with a standard solution of potassium poly(vinyl sulfate) (PVSK) using crystal violet (CV) as an photometric indicator cation. The end point was detected by a sharp absorbance change due to an abrupt decrease in the concentration of CV. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant existed in the concentration range from 2 to 10 × 10(-6) eq mol L(-1). Back-titration was based on adding an excess amount of PVSK to a sample solution containing CV, which was titrated with a standard solution of poly(diallyldimethylammonium chloride) (PDADMAC). The calibration curve of the PHMB-HCl concentration to the end point volume of the titrant was also linear in the concentration range from 2 to 8 × 10(-6) eq mol L(-1). Both photometric titrations were applied to the determination of PHMB-HCl in a few contact-lens detergents. Back-titration showed a clear end point, but direct titration showed an unclear end point. The results of the back-titration of PHMB-HCl were compared with the content registered in its labels. 2011 © The Japan Society for Analytical Chemistry

  11. Theoretical considerations and a simple method for measuring alkalinity and acidity in low-pH waters by gran titration

    USGS Publications Warehouse

    Barringer, J.L.; Johnsson, P.A.

    1996-01-01

    Titrations for alkalinity and acidity using the technique described by Gran (1952, Determination of the equivalence point in potentiometric titrations, Part II: The Analyst, v. 77, p. 661-671) have been employed in the analysis of low-pH natural waters. This report includes a synopsis of the theory and calculations associated with Gran's technique and presents a simple and inexpensive method for performing alkalinity and acidity determinations. However, potential sources of error introduced by the chemical character of some waters may limit the utility of Gran's technique. Therefore, the cost- and time-efficient method for performing alkalinity and acidity determinations described in this report is useful for exploring the suitability of Gran's technique in studies of water chemistry.

  12. Effect of contact angle, zeta potential and particles size on the in vitro studies of Al2O3 and SiO2 nanoparticles.

    PubMed

    Karunakaran, Gopalu; Suriyaprabha, Rangaraj; Rajendran, Venkatachalam; Kannan, Narayanasamy

    2015-02-01

    Currently, nanometal oxides find their role in different biological applications such as tissue engineering, implant and bone replacement materials. Owing to the increased use of nanoparticles, it is necessary to understand their release and toxicity in the biological system. In this regard, three independent studies such as in vitro cytotoxicity, antioxidant activity and biocompatibility of nano- and micrometal oxide particles such as alumina (Al2O3) and silica (SiO2) are evaluated. It is evident from cell viability study that nanoAl2O3 and SiO2 particles are less toxic when compared with microAl2O3 and SiO2 to NIH 3T3 cell lines up to 200 µg/ml. Antioxidant properties of micro- and nanoAl2O3 in terms of radical scavenging percentage for micro- and nanoAl2O3 are 59.1% and 72.1%, respectively, at 100 mg. Similarly, the radical scavenging percentage of nano- and bulk SiO2 are 81.0% and 67.2%, respectively. The present study reveals that the cellular behaviour, interaction and biocompatibility of metal oxides differ with dose, particle size, contact angle and zeta potential. The present study opens up a new strategy to analyse in vitro nanotoxicity.

  13. Efficacy and Tolerability of Two Different Kinds of Titration of Paroxetine Hydrocloride Solution: an Observational Study.

    PubMed

    Ielmini, Marta; Poloni, Nicola; Caselli, Ivano; Bianchi, Lucia; Diurni, Marcello; Vender, Simone; Callegari, Camilla

    2018-03-13

    Depressive disorders are expected to be the second highest cause of morbidity in the world until few years. Moreover, patients with depression frequently show many side effects and low compliance to therapy. To find a more tolerated and more efficacy therapy is a growing need. This observational study investigates the efficacy, safety and tolerability of paroxetine hydrochloride comparing slow versus standard titration in a population affected by Depressive Disoders (according to DSM 5). 186 outpatients were assessed throught the following scales: Hamilton Depression Rating Scale (HDRS) for depression and World Health Organization Quality of Life Scale Bref for the perceived quality of life (WHOQOL BREF). Treatment-emerged Adverse Events (TEAEs) were recorded throught self-reports. Statystical analysys was performed by GraphPad Prism Version 5.1. The efficacy of paroxetine was confirmed in both titrations by the number of clinical remitters (HDRS ≤ 7 at 12 weeks for 53% of the standard titration group and 58% of the slow titration group), without differences. About safety and tolerability there were more frequent TEAEs among the standard titration group (p < 0.01). Comparing WHOQOL BREF between the two groups at the recruitment and at the twelth week emerged a statistically significant difference (p = 0.003), with highest scores reached in slow titration group. Although the short observation period is an evident limit, this study is consistent to the literature about the efficacy of both titrations of paroxetine to improve depression and shows promising results about the increased tolerability of paroxetine slow titration.

  14. Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction.

    PubMed

    Eble, Johannes A

    2018-02-15

    The dissociation constant describes the interaction between two partners in the binding equilibrium and is a measure of their affinity. It is a crucial parameter to compare different ligands, e.g., competitive inhibitors, protein isoforms and mutants, for their binding strength to a binding partner. Dissociation constants are determined by plotting concentrations of bound versus free ligand as binding curves. In contrast, titration curves, in which a signal that is proportional to the concentration of bound ligand is plotted against the total concentration of added ligand, are much easier to record. The signal can be detected spectroscopically and by enzyme-linked immunosorbent assay (ELISA). This is exemplified in a protocol for a titration ELISA that measures the binding of the snake venom-derived rhodocetin to its immobilized target domain of α2β1 integrin. Titration ELISAs are versatile and widely used. Any pair of interacting proteins can be used as immobilized receptor and soluble ligand, provided that both proteins are pure, and their concentrations are known. The difficulty so far has been to determine the dissociation constant from a titration curve. In this study, a mathematical function underlying titration curves is introduced. Without any error-prone graphical estimation of a saturation yield, this algorithm allows processing of the raw data (signal intensities at different concentrations of added ligand) directly by mathematical evaluation via non-linear regression. Thus, several titration curves can be recorded simultaneously and transformed into a set of characteristic parameters, among them the dissociation constant and the concentration of binding-active receptor, and they can be evaluated statistically. When combined with this algorithm, titration ELISAs gain the advantage of directly presenting the dissociation constant. Therefore, they may be used more efficiently in the future.

  15. High-resolution ultraviolet observations of interstellar lines toward Zeta Persei observed with the balloon-borne ultraviolet stellar spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snow, T.P.; Lamers, H.J.G.L.M.; Joseph, C.L.

    1987-10-01

    The balloon-borne ultraviolet stellar spectrometer payload has been used to obtain high-resolution data on interstellar absorption lines toward Zeta Per. The only lines clearly present in the 2150-2450 region were several Fe II features, which show double structure. The two velocity components were sufficiently well separated that it was possible to construct separate curves of growth to derive the Fe II column densities for the individual components. These column densities and the component velocity separation were then used to compute a realistic two-component curve of growth for the line of sight to Zeta Per, which was then used to reanalyzemore » existing ultraviolet data from Copernicus. The results were generally similar to an earlier two-component analysis of the Copernicus data, with the important exception that the silicon depletion increased from near zero to about 1 dex. This makes the Zeta Per depletion pattern quite similar to those derived for other reddened lines of sight, supporting the viewpoint that the general diffuse interstellar medium has a nearly constant pattern of depletions. 31 references.« less

  16. Protofit: A program for determining surface protonation constants from titration data

    NASA Astrophysics Data System (ADS)

    Turner, Benjamin F.; Fein, Jeremy B.

    2006-11-01

    Determining the surface protonation behavior of natural adsorbents is essential to understand how they interact with their environments. ProtoFit is a tool for analysis of acid-base titration data and optimization of surface protonation models. The program offers a number of useful features including: (1) enables visualization of adsorbent buffering behavior; (2) uses an optimization approach independent of starting titration conditions or initial surface charge; (3) does not require an initial surface charge to be defined or to be treated as an optimizable parameter; (4) includes an error analysis intrinsically as part of the computational methods; and (5) generates simulated titration curves for comparison with observation. ProtoFit will typically be run through ProtoFit-GUI, a graphical user interface providing user-friendly control of model optimization, simulation, and data visualization. ProtoFit calculates an adsorbent proton buffering value as a function of pH from raw titration data (including pH and volume of acid or base added). The data is reduced to a form where the protons required to change the pH of the solution are subtracted out, leaving protons exchanged between solution and surface per unit mass of adsorbent as a function of pH. The buffering intensity function Qads* is calculated as the instantaneous slope of this reduced titration curve. Parameters for a surface complexation model are obtained by minimizing the sum of squares between the modeled (i.e. simulated) buffering intensity curve and the experimental data. The variance in the slope estimate, intrinsically produced as part of the Qads* calculation, can be used to weight the sum of squares calculation between the measured buffering intensity and a simulated curve. Effects of analytical error on data visualization and model optimization are discussed. Examples are provided of using ProtoFit for data visualization, model optimization, and model evaluation.

  17. Acid-base titrations using microfluidic paper-based analytical devices.

    PubMed

    Karita, Shingo; Kaneta, Takashi

    2014-12-16

    Rapid and simple acid-base titration was accomplished using a novel microfluidic paper-based analytical device (μPAD). The μPAD was fabricated by wax printing and consisted of ten reservoirs for reaction and detection. The reaction reservoirs contained various amounts of a primary standard substance, potassium hydrogen phthalate (KHPth), whereas a constant amount of phenolphthalein was added to all the detection reservoirs. A sample solution containing NaOH was dropped onto the center of the μPAD and was allowed to spread to the reaction reservoirs where the KHPth neutralized it. When the amount of NaOH exceeded that of the KHPth in the reaction reservoirs, unneutralized hydroxide ion penetrated the detection reservoirs, resulting in a color reaction from the phenolphthalein. Therefore, the number of the detection reservoirs with no color change determined the concentration of the NaOH in the sample solution. The titration was completed within 1 min by visually determining the end point, which required neither instrumentation nor software. The volumes of the KHPth and phenolphthalein solutions added to the corresponding reservoirs were optimized to obtain reproducible and accurate results for the concentration of NaOH. The μPADs determined the concentration of NaOH at orders of magnitude ranging from 0.01 to 1 M. An acid sample, HCl, was also determined using Na2CO3 as a primary standard substance instead of KHPth. Furthermore, the μPAD was applicable to the titrations of nitric acid, sulfuric acid, acetic acid, and ammonia solutions. The μPADs were stable for more than 1 month when stored in darkness at room temperature, although this was reduced to only 5 days under daylight conditions. The analysis of acidic hot spring water was also demonstrated in the field using the μPAD, and the results agreed well with those obtained by classic acid-base titration.

  18. The benefit of HH during the CPAP titration in the cool sleeping environment.

    PubMed

    Li, Yayong; Wang, Yina

    2016-12-01

    Upper airway symptom associated with continuous positive airway pressure (CPAP) treatment is an important factor influencing CPAP adherence. There are conflicting data on the effect of a heated humidifier (HH) during CPAP titration for patients with obstructive sleep apnea hypopnea syndrome (OSAHS). This study investigated the effects of HH during CPAP titration in the cool sleeping environment. Forty newly diagnosed OSAHS patients who received CPAP titration in the cool sleeping environment were randomly assigned to HH and non-HH groups. A questionnaire was used to evaluate upper airway symptoms, satisfaction with initial CPAP treatment, and willingness to further use CPAP. Some therapy parameters including leak, apnea hypopnea index (AHI) reduction, and optimal CPAP pressure level were analyzed. We compared these subjective and objective data between the two groups. In subjective sensation, the use of HH can alleviate upper airway symptoms associated with CPAP titration (P < 0.001). The HH group has benefit in satisfaction with initial CPAP treatment (P < 0.001) and further willingness to use CPAP (P < 0.01), although there were no significant differences in leak, AHI reduction, and optimal CPAP pressure between the two groups. The use of HH is recommended during CPAP titration in the cool sleeping environment because of its benefit in the treatment of upper airway symptoms associated with CPAP therapy and improvement of the CPAP acceptance.

  19. HST-WFC3 Near-Infrared Spectroscopy of Quenched Galaxies at zeta approx 1.5 from the WISP Survey: Stellar Populations Properties

    NASA Technical Reports Server (NTRS)

    Bedregal, A. G.; Scarlata, C.; Henry, A. L.; Atek, H.; Rafelski, M.; Teplitz, H. I.; Dominguez, A.; Siana, B.; Colbert, J. W.; Malkan, M.; hide

    2013-01-01

    We combine Hubble Space Telescope (HST) G102 and G141 near-IR (NIR) grism spectroscopy with HST/WFC3- UVIS, HST/WFC3-IR, and Spitzer/IRAC [3.6 microns] photometry to assemble a sample of massive (log(Mstar/M solar mass) at approx 11.0) and quenched (specific star formation rate < 0.01 G/yr(exp -1) galaxies at zeta approx 1.5. Our sample of 41 galaxies is the largest with G102+G141 NIR spectroscopy for quenched sources at these redshifts. In contrast to the local universe, zeta approx 1.5 quenched galaxies in the high-mass range have a wide range of stellar population properties. We find that their spectral energy distributions (SEDs) are well fitted with exponentially decreasing star formation histories and short star formation timescales (tau less than or equal to 100 M/yr). Quenched galaxies also show a wide distribution in ages, between 1 and 4 G/yr. In the (u - r)0-versus-mass space quenched galaxies have a large spread in rest-frame color at a given mass. Most quenched galaxies populate the zeta appro. 1.5 red sequence (RS), but an important fraction of them (32%) have substantially bluer colors. Although with a large spread, we find that the quenched galaxies on the RS have older median ages (3.1 G/yr) than the quenched galaxies off the RS (1.5 G/yr). We also show that a rejuvenated SED cannot reproduce the observed stacked spectra of (the bluer) quenched galaxies off the RS. We derive the upper limit on the fraction of massive galaxies on the RS at zeta approx 1.5 to be <43%.We speculate that the young quenched galaxies off the RS are in a transition phase between vigorous star formation at zeta > 2 and the zeta approx 1.5 RS. According to their estimated ages, the time required for quenched galaxies off the RS to join their counterparts on the z approx. 1.5 RS is of the order of approx. 1G/yr.

  20. Immediate effect of CPAP titration on perceived health related quality of life: a prospective observational study.

    PubMed

    Iacono Isidoro, Serena; Salvaggio, Adriana; Lo Bue, Anna; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe

    2016-12-01

    Perceived Health Related Quality of Life (HRQoL) is impaired in obstructive sleep apnea (OSA). This study examines changes in HRQoL aspects occurring immediately after CPAP titration. Furthermore, we analyzed variations in each gender and in patients undergoing home or laboratory-based CPAP titration pathways. Twohundredfive outpatients (151 M) (56.7 ± 10.3 years) were evaluated, before first visit and nocturnal diagnostic examination (T0), and the morning after CPAP titration (T1). Two self-reported HRQoL questionnaires were administered: Psychological General Well-Being Index (PGWBI), composed by six subscales, and 12-Item Short-Form Health Survey (SF-12), including Physical (PCS) and Mental Component Summaries (MCS). CPAP titration was performed using auto-adjusting CPAP units at patients' home or in the sleep laboratory. PGWBI scores at T1 improved compared to T0 (p < 0.0001). A similar improvement was observed in SF-12 MCS (p = 0.0011), but not in SF-12 PCS. Changes were independent from anthropometric parameters, OSA severity and excessive daytime sleepiness. Gender comparisons showed better HRQoL in males at both times. At T0, patients who received home or laboratory CPAP titration pathways did not show any differences in PGWBI and SF-12 scores. At T1, PGWBI and SF-12 MCS improved in both home and laboratory groups. This study gives evidence that first time CPAP application for titration can lead to a general increase in perceived well-being. Gender comparisons showed better perceived HRQoL with more subscales improvements in males after CPAP titration. The improvement was similar with both home and laboratory CPAP titration pathways.

  1. Acid Rain Analysis by Standard Addition Titration.

    ERIC Educational Resources Information Center

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  2. A new method for determining the acid number of biodiesel based on coulometric titration.

    PubMed

    Barbieri Gonzaga, Fabiano; Pereira Sobral, Sidney

    2012-08-15

    A new method is proposed for determining the acid number (AN) of biodiesel using coulometric titration with potentiometric detection, basically employing a potentiostat/galvanostat and an electrochemical cell containing a platinum electrode, a silver electrode, and a combination pH electrode. The method involves a sequential application of a constant current between the platinum (cathode) and silver (anode) electrodes, followed by measuring the potential of the combination pH electrode, using an isopropanol/water mixture as solvent and LiCl as the supporting electrolyte. A preliminary evaluation of the new method, using acetic acid for doping a biodiesel sample, showed an average recovery of 100.1%. Compared to a volumetric titration-based method for determining the AN of several biodiesel samples (ranging from about 0.18 to 0.95 mg g(-1)), the new method produced statistically similar results with better repeatability. Compared to other works reported in the literature, the new method presented an average repeatability up to 3.2 times better and employed a sample size up to 20 times smaller. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Down-titration of biologics for the treatment of rheumatoid arthritis: a systematic literature review.

    PubMed

    Lau, Chak Sing; Gibofsky, Allan; Damjanov, Nemanja; Lula, Sadiq; Marshall, Lisa; Jones, Heather; Emery, Paul

    2017-11-01

    Biologic therapies have improved the management of rheumatoid arthritis (RA) and the treat-to-target approach has resulted in many patients achieving remission. In the current treatment landscape, clinicians have begun considering dose reduction/tapering for their patients. Rheumatology guidelines in Asia, Europe, and the United States include down-titration of biologics but admit that the level of evidence is moderate. We conducted a systematic literature review to assess the published studies that evaluate down-titration of biologics in RA. The published literature was searched for studies that down-titrated the following biologics: abatacept, adalimumab, certolizumab, etanercept, golimumab, infliximab, rituximab, and tocilizumab. Eligible studies included randomized controlled trials (RCTs), non-RCTs, observational, and pharmacoeconomic studies. The outcomes of interest were (1) efficacy and health-related quality of life, (2) disease flares, and (3) impact on cost. Eleven full-text publications were identified; only three were RCTs. Study results suggest that dosing down may be an option in many patients who have achieved remission or low disease activity. However, some patients are likely to experience a disease flare. Across the studies, the definition of disease flare and the down-titration criteria were inconsistent, making it difficult to conclude which patients may be appropriate and when to attempt down-titration. Studies have evaluated the practice of dosing down biologic therapy in patients with RA; however, a relatively small number of RCTs have been published. Although down-titration may be an option for some patients in LDA or remission, additional RCTs are needed to provide guidance on this practice.

  4. Clinical, polysomnographic, and CPAP titration features of obstructive sleep apnea: Mixed versus purely obstructive type.

    PubMed

    Lee, Sang-Ahm; Lee, Gha-Hyun; Chung, Yoo-Sam; Kim, Woo Sung

    2015-08-15

    To determine whether obstructive sleep apnea syndrome (OSAS) patients with mixed sleep apnea (MSA) have different clinical, polysomnographic, and continuous positive airway pressure (CPAP) titration findings compared to OSAS patients without MSA. We retrospectively reviewed the records of OSAS patients who had undergone CPAP titration and categorized them into pure-OSA and mixed-OSA groups. Demographic features, daytime sleepiness, and apnea severity were compared between the two groups using univariate and multivariate analyses. CPAP titration findings were also compared between the two groups. One hundred and ninety-five subjects (n=126 pure-OSA; n=69 mixed-OSA) were included in the analysis. Compared to the pure-OSA group, the mixed-OSA group had a higher percentage of males (p=0.003) and a higher body mass index (p=0.044), Epworth Sleepiness Scale score (p=0.028), and apnea-hypopnea index (AHI) (p<0.001). In logistic regression analysis, older age, male sex, and higher body mass index were independently associated with mixed-OSA before PSG study. When using AHI as a covariable, the higher AHI with older age, male sex, and daytime sleepiness was independently related to mixed-OSA. The mixed-OSA group had a higher percentage of patients with complex sleep apnea, a lower percentage of patients with optimal titration, and a higher titrated pressure than the pure-OSA group. Severe OSA, older age, male sex, obesity, and daytime sleepiness were related to mixed-OSA. Complex sleep apnea, less optimal titration, and a higher titrated CPAP were also associated with MSA in OSAS patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. A systematic review on the effectiveness of titratable over nontitratable mandibular advancement appliances for sleep apnea.

    PubMed

    Sivaramakrishnan, Gowri; Sridharan, Kannan

    2017-01-01

    Mandibular advancement appliances are being tested for use in patients with obstructive sleep apnea (OSA). However, the effectiveness of titration of these appliances does not have conclusive evidence. Systematic reviews help us to compile all available clinical evidence using statistical principles. Hence, the aim of this systematic review is to identify the effectiveness of titratable over nontitratable mandibular advancement appliances in patients with mild to moderate OSA. This review objective is to identify if titration of these appliances produce significant benefits over fixed appliances. Electronic databases were searched to identify eligible studies based on set inclusion criteria. Data extraction form was created and the data were extracted. The participants were mild to moderate OSA patients who received mandibular advancement appliances. Studies included a comparison between titratable and nontitratable mandibular advancement appliance. Of the five included studies, three were observational and two were a randomized trial. All these studies were conducted in adults. The outcome attributes were polysomnographic readings and apnea-hypopnea index (AHI). A significant heterogeneity was seen between the eligible studies and hence a meta-analysis could not be performed. The results from this systematic review did not show significant advantages of titratable appliances, although titratable appliances performed better from individual studies as regards to reduction in AHI and polysomnography. The reason is the lack of sufficient clinical trials on the same. More high quality randomized controlled trials comparing titratable and fixed appliances have to be initiated to get to conclusive evidence.

  6. Isothermal Titration Calorimetry in the Student Laboratory

    ERIC Educational Resources Information Center

    Wadso, Lars; Li, Yujing; Li, Xi

    2011-01-01

    Isothermal titration calorimetry (ITC) is the measurement of the heat produced by the stepwise addition of one substance to another. It is a common experimental technique, for example, in pharmaceutical science, to measure equilibrium constants and reaction enthalpies. We describe a stirring device and an injection pump that can be used with a…

  7. Using Spreadsheets to Produce Acid-Base Titration Curves.

    ERIC Educational Resources Information Center

    Cawley, Martin James; Parkinson, John

    1995-01-01

    Describes two spreadsheets for producing acid-base titration curves, one uses relatively simple cell formulae that can be written into the spreadsheet by inexperienced students and the second uses more complex formulae that are best written by the teacher. (JRH)

  8. Total Acid Value Titration of Hydrotreated Biomass Fast Pyrolysis Oil: Determination of Carboxylic Acids and Phenolics with Multiple End-Point Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christensen, E.; Alleman, T. L.; McCormick, R. L.

    Total acid value titration has long been used to estimate corrosive potential of petroleum crude oil and fuel oil products. The method commonly used for this measurement, ASTM D664, utilizes KOH in isopropanol as the titrant with potentiometric end point determination by pH sensing electrode and Ag/AgCl reference electrode with LiCl electrolyte. A natural application of the D664 method is titration of pyrolysis-derived bio-oil, which is a candidate for refinery upgrading to produce drop in fuels. Determining the total acid value of pyrolysis derived bio-oil has proven challenging and not necessarily amenable to the methodology employed for petroleum products duemore » to the different nature of acids present. We presented an acid value titration for bio-oil products in our previous publication which also utilizes potentiometry using tetrabutylammonium hydroxide in place of KOH as the titrant and tetraethylammonium bromide in place of LiCl as the reference electrolyte to improve the detection of these types of acids. This method was shown to detect numerous end points in samples of bio-oil that were not detected by D664. These end points were attributed to carboxylic acids and phenolics based on the results of HPLC and GC-MS studies. Additional work has led to refinement of the method and it has been established that both carboxylic acids and phenolics can be determined accurately. Use of pH buffer calibration to determine half-neutralization potentials of acids in conjunction with the analysis of model compounds has allowed us to conclude that this titration method is suitable for the determination of total acid value of pyrolysis oil and can be used to differentiate and quantify weak acid species. The measurement of phenolics in bio-oil is subject to a relatively high limit of detection, which may limit the utility of titrimetric methodology for characterizing the acidic potential of pyrolysis oil and products.« less

  9. Impact of hypoglycemic events and HbA1c level on sulfonylurea discontinuation and down-titration.

    PubMed

    Laires, Pedro A; Tang, Jackson; Fan, Chun Po Steve; Li, Zhiyi; Qiu, Ying; Iglay, Kristy

    2017-04-01

    A retrospective cohort study using GE Centricity electronic medical records assessed the association between post-index hypoglycemia and HbA1c with discontinuation and down-titration of sulfonylureas among patients with Type 2 diabetes mellitus. Adult patients with an index prescription for a sulfonylurea and ≥12 months' continuous records pre- and post-index were eligible. Sulfonylurea discontinuation and down-titration was assessed 1-year post-index. Discontinuation occurred if the date of a prescription was >90 days from the preceding prescription plus days of supply. Down-titration occurred when a subsequent prescription was lower than the index dose. Cox regression assessed the association between post-index hypoglycemia and HbA1c with time to sulfonylurea discontinuation and down-titration, as well as other factors. 28,371 participants were included in the study; 13,459 (47.4%) were discontinuers, 717 (2.5%) were down-titraters, and 14,195 (50.0%) were continuers. 0.6% of continuers experienced hypoglycemia 1-year post-index, compared with 3.1% of down-titraters and 0.8% of discontinuers (p < 0.0001). Patients with post-index hypoglycemia had a significantly higher rate of discontinuation (hazard ratio [HR] = 1.82, 95% CI: 1.47-2.23) and down-titration (HR = 4.25, 95% CI: 1.92-8.03). Patients with higher post-index HbA1c and use of 2 nd generation sulfonylureas had an increased rate of discontinuation (HR = 1.05, 95% CI: 1.04-1.06; HR = 1.19, 95% CI: 1.14-1.24, respectively). Approximately half of participants who initiated sulfonylureas discontinued or down-titrated therapy within one year. Both post-index hypoglycemia and higher HbA1c were significant risk factors for sulfonylurea treatment change.

  10. Thermometric titration of acids in pyridine.

    PubMed

    Vidal, R; Mukherjee, L M

    1974-04-01

    Thermometric titration of HClO(4), HI, HNO(3), HBr, picric acid o-nitrobenzoic acid, 2,4- and 2,5-dinitrophenol, acetic acid and benzoic acid have been attempted in pyridine as solvent, using 1,3-diphenylguanidine as the base. Except in the case of 2,5-dinitrophenol, acetic acid and benzoic acid, the results are, in general, reasonably satisfactory. The approximate molar heats of neutralization have been calculated.

  11. 14-3-3 zeta is a molecular target in guggulsterone induced apoptosis in head and neck cancer cells.

    PubMed

    Macha, Muzafar A; Matta, Ajay; Chauhan, Ss; Siu, Kw Michael; Ralhan, Ranju

    2010-11-30

    The five-year survival rates for head and neck squamous cell carcinoma (HNSCC) patients are less than 50%, and the prognosis has not improved, despite advancements in standard multi-modality therapies. Hence major emphasis is being laid on identification of novel molecular targets and development of multi-targeted therapies. 14-3-3 zeta, a multifunctional phospho-serine/phospho-threonine binding protein, is emerging as an effector of pro-survival signaling by binding to several proteins involved in apoptosis (Bad, FKHRL1 and ASK1) and may serve as an appropriate target for head and neck cancer therapy. Herein, we determined effect of guggulsterone (GS), a farnesoid X receptor antagonist, on 14-3-3 zeta associated molecular pathways for abrogation of apoptosis in head and neck cancer cells. Head and neck cancer cells were treated with guggulsterone (GS). Effect of GS-treatment was evaluated using cell viability (MTT) assay and apoptosis was verified by annexin V, DNA fragmentation and M30 CytoDeath antibody assay. Mechanism of GS-induced apoptosis was determined by western blotting and co-IP assays using specific antibodies. Using in vitro models of head and neck cancer, we showed 14-3-3 zeta as a key player regulating apoptosis in GS treated SCC4 cells. Treatment with GS releases BAD from the inhibitory action of 14-3-3 zeta in proliferating HNSCC cells by activating protein phosphatase 2A (PP2A). These events initiate the intrinsic mitochondrial pathway of apoptosis, as revealed by increased levels of cytochrome c in cytoplasmic extracts of GS-treated SCC4 cells. In addition, GS treatment significantly reduced the expression of anti-apoptotic proteins, Bcl-2, xIAP, Mcl1, survivin, cyclin D1 and c-myc, thus committing cells to apoptosis. These events were followed by activation of caspase 9, caspase 8 and caspase 3 leading to cleavage of its downstream target, poly-ADP-ribose phosphate (PARP). GS targets 14-3-3 zeta associated cellular pathways for reducing

  12. Comparison of the clinical outcomes between unattended home APAP and polysomnography manual titration in obstructive sleep apnea patients.

    PubMed

    Wongsritrang, Krongthong; Fueangkamloon, Sumet

    2013-09-01

    To compare the clinical outcomes and determine the difference in therapeutic pressure between Automatic positive airway pressure (APAP) and polysomnography manual titration. Fifty patients of obstructive sleep apnea (OSA), moderate to severe cases, were randomized into two groups of intervention: 95-percentile pressure derived from APAP titration and an optimal pressure derived from manual titration. Clinical outcomes were assessed before and after four weeks. The average 95-percentile pressure derived from APAP titration was 11.7 +/- 0.3 cmH2O with median mask leak 1.3 L/min. The average optimal pressure derived from manual titration was 8.2 +/- 0.3 cmH2O. Pearson correlation analysis showed weak positive correlation (r = 0.336, p = 0.017). The Epworth Sleepiness Score (ESS), Quality of life tests: PSQI (Pittsburg Sleep Quality Index), and SF-36 (Medical Outcomes Study 36-Item Short-Form Health Survey) were improved significantly in both groups, but there were no statistical significant differences between groups. An APAP titration is an effective method of pressure determination for conventional CPAP therapy and shows no difference in clinical outcomes comparing the standard titration.

  13. A Titration Technique for Demonstrating a Magma Replenishment Model.

    ERIC Educational Resources Information Center

    Hodder, A. P. W.

    1983-01-01

    Conductiometric titrations can be used to simulate subduction-setting volcanism. Suggestions are made as to the use of this technique in teaching volcanic mechanisms and geochemical indications of tectonic settings. (JN)

  14. Thermodynamic analysis of Bacillus subtilis endospore protonation using isothermal titration calorimetry

    NASA Astrophysics Data System (ADS)

    Harrold, Zoë R.; Gorman-Lewis, Drew

    2013-05-01

    Bacterial proton and metal adsorption reactions have the capacity to affect metal speciation and transport in aqueous environments. We coupled potentiometric titration and isothermal titration calorimetry (ITC) analyses to study Bacillus subtilis spore-proton adsorption. We modeled the potentiometric data using a four and five-site non-electrostatic surface complexation model (NE-SCM). Heats of spore surface protonation from coupled ITC analyses were used to determine site specific enthalpies of protonation based on NE-SCMs. The five-site model resulted in a substantially better model fit for the heats of protonation but did not significantly improve the potentiometric titration model fit. The improvement observed in the five-site protonation heat model suggests the presence of a highly exothermic protonation reaction circa pH 7 that cannot be resolved in the less sensitive potentiometric data. From the log Ks and enthalpies we calculated corresponding site specific entropies. Log Ks and site concentrations describing spore surface protonation are statistically equivalent to B. subtilis cell surface protonation constants. Spore surface protonation enthalpies, however, are more exothermic relative to cell based adsorption suggesting a different bonding environment. The thermodynamic parameters defined in this study provide insight on molecular scale spore-surface protonation reactions. Coupled ITC and potentiometric titrations can reveal highly exothermic, and possibly endothermic, adsorption reactions that are overshadowed in potentiometric models alone. Spore-proton adsorption NE-SCMs derived in this study provide a framework for future metal adsorption studies.

  15. Molecular Weight Measurement of Biobased Furan Polyamides via Non-Aqueous Potentiometric Titration

    DTIC Science & Technology

    2013-06-01

    electromagnetic fields, all titrations were completed in a chemical hood, which acted as a Faraday cage (a shield used to blocks external static and...while using DMF as a solvent. Additionally, no Faraday cage was used in the experimental setup, so the titrations were conducted inside the chemical...monomer was becoming more soluble in glacial acetic acid and the amount of chlorobenzene had less of an effect on the solution properties (i.e

  16. Assessment of two theoretical methods to estimate potentiometric titration curves of peptides: comparison with experiment.

    PubMed

    Makowska, Joanna; Bagiñska, Katarzyna; Makowski, Mariusz; Jagielska, Anna; Liwo, Adam; Kasprzykowski, Franciszek; Chmurzyñski, Lech; Scheraga, Harold A

    2006-03-09

    We compared the ability of two theoretical methods of pH-dependent conformational calculations to reproduce experimental potentiometric titration curves of two models of peptides: Ac-K5-NHMe in 95% methanol (MeOH)/5% water mixture and Ac-XX(A)7OO-NH2 (XAO) (where X is diaminobutyric acid, A is alanine, and O is ornithine) in water, methanol (MeOH), and dimethyl sulfoxide (DMSO), respectively. The titration curve of the former was taken from the literature, and the curve of the latter was determined in this work. The first theoretical method involves a conformational search using the electrostatically driven Monte Carlo (EDMC) method with a low-cost energy function (ECEPP/3 plus the SRFOPT surface-solvation model, assumming that all titratable groups are uncharged) and subsequent reevaluation of the free energy at a given pH with the Poisson-Boltzmann equation, considering variable protonation states. In the second procedure, molecular dynamics (MD) simulations are run with the AMBER force field and the generalized Born model of electrostatic solvation, and the protonation states are sampled during constant-pH MD runs. In all three solvents, the first pKa of XAO is strongly downshifted compared to the value for the reference compounds (ethylamine and propylamine, respectively); the water and methanol curves have one, and the DMSO curve has two jumps characteristic of remarkable differences in the dissociation constants of acidic groups. The predicted titration curves of Ac-K5-NHMe are in good agreement with the experimental ones; better agreement is achieved with the MD-based method. The titration curves of XAO in methanol and DMSO, calculated using the MD-based approach, trace the shape of the experimental curves, reproducing the pH jump, while those calculated with the EDMC-based approach and the titration curve in water calculated using the MD-based approach have smooth shapes characteristic of the titration of weak multifunctional acids with small differences

  17. Concurrent determination of total serum calcium and magnesium by thermometric titration with ethylenediaminetetraacetate.

    PubMed

    Callicott, R H; Carr, P W

    1976-07-01

    Total serum calcium and magnesium may be determined in one thermometric titration, with disodium ethylenediaminetetraacetate as the titrant. A 1-ml serum sample is diluted with 1 ml of tris(hydroxymethyl)aminomethane buffer (pH 8) and titrated at a constant rate with a motorized syringe buret. Results by the thermometric method compared well with those by atomic absorption spectroscopy.

  18. Non-Aqueous Titration Method for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor-Pashow, Kathryn M. L.; Jones, Daniel H.

    A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration wasmore » determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.« less

  19. Prescribing and up-titration in recently hospitalized heart failure patients attending a disease management program.

    PubMed

    Carroll, Robert; Mudge, Alison; Suna, Jessica; Denaro, Charles; Atherton, John

    2016-08-01

    Heart failure (HF) medications improve clinical outcomes, with optimal doses defined in clinical trials. Patient, provider and system barriers may limit achievement of optimal doses in real life settings, although disease management programs (HF-DMPs) can facilitate up-titration. Secondary analysis of a prospective cohort of 216 participants recently hospitalized with systolic HF, attending 5 HF-DMPs in Queensland, Australia. Medication history at baseline (6weeks after discharge) and 6months provided data to describe prescription rates, dosage and optimal titration of HF medications, and associations with patient and system factors were explored. At baseline, 94% were on an angiotensin converting enzyme inhibitor/angiotensin II receptor blocker (ACEI/ARB), 94% on a beta-blocker (BB) and 42% on a mineralocorticoid receptor antagonist (MRA). The proportion of participants on optimal doses of ACEI/ARB increased from 38% (baseline) to 52% (6months, p=0.001) and on optimal BB dose from 23% to 49% (p<0.001). Significant barriers to ACEI/ARB up-titration were body mass index (BMI)<25, female gender, polypharmacy, previously diagnosed HF, and tertiary hospital. Significant barriers for BB up-titration were BMI<25, previously diagnosed HF and non-cardiologist care. Effective up-titration in HF DMPs is influenced by patient, disease and service factors. Better understanding of barriers to effective up-titration in women, normal weight, and established HF patients may help provide targeted strategies for improving outcomes in these groups. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Measuring titratable alkalinity by single versus double endpoint titration: An evaluation in two cyprinodont species and implications for characterizing net H+ flux in aquatic organisms.

    PubMed

    Brix, Kevin V; Wood, Chris M; Grosell, Martin

    2013-01-01

    In this study, Na(+) uptake and acid-base balance in the euryhaline pupfish Cyprinodon variegatus variegatus were characterized when fish were exposed to pH 4.5 freshwater (7mM Na(+)). Similar to the related cyprinodont, Fundulus heteroclitus, Na(+) uptake was significantly inhibited when exposed to low pH water. However, it initially appeared that C. v. variegatus increased apparent net acid excretion at low pH relative to circumneutral pH. This result is opposite to previous observations for F. heteroclitus under similar conditions where fish were observed to switch from apparent net H(+) excretion at circumneutral pH to apparent net H(+) uptake at low pH. Further investigation revealed disparate observations between these studies were the result of using double endpoint titrations to measure titratable alkalinity fluxes in the current study, while the earlier study utilized single endpoint titrations to measure these fluxes (i.e.,. Cyprinodon acid-base transport is qualitatively similar to Fundulus when characterized using single endpoint titrations). This led to a comparative investigation of these two methods. We hypothesized that either the single endpoint methodology was being influenced by a change in the buffer capacity of the water (e.g., mucus being released by the fish) at low pH, or the double endpoint methodology was not properly accounting for ammonia flux by the fish. A series of follow-up experiments indicated that buffer capacity of the water did not change significantly, that excretion of protein (a surrogate for mucus) was actually reduced at low pH, and that the double endpoint methodology does not properly account for NH(3) excretion by fish under low pH conditions. As a result, it overestimates net H(+) excretion during low pH exposure. After applying the maximum possible correction for this error (i.e., assuming that all ammonia is excreted as NH(3)), the double endpoint methodology indicates that net H(+) transport was reduced to

  1. Mapping Protein–Protein Interactions of the Resistance-Related Bacterial Zeta Toxin–Epsilon Antitoxin Complex (ε2ζ2) with High Affinity Peptide Ligands Using Fluorescence Polarization

    PubMed Central

    Fernández-Bachiller, María Isabel; Brzozowska, Iwona; Odolczyk, Norbert; Zielenkiewicz, Urszula; Zielenkiewicz, Piotr; Rademann, Jörg

    2016-01-01

    Toxin–antitoxin systems constitute a native survival strategy of pathogenic bacteria and thus are potential targets of antibiotic drugs. Here, we target the Zeta–Epsilon toxin–antitoxin system, which is responsible for the stable maintenance of certain multiresistance plasmids in Gram-positive bacteria. Peptide ligands were designed on the basis of the ε2ζ2 complex. Three α helices of Zeta forming the protein–protein interaction (PPI) site were selected and peptides were designed conserving the residues interacting with Epsilon antitoxin while substituting residues binding intramolecularly to other parts of Zeta. Designed peptides were synthesized with an N-terminal fluoresceinyl-carboxy-residue for binding assays and provided active ligands, which were used to define the hot spots of the ε2ζ2 complex. Further shortening and modification of the binding peptides provided ligands with affinities <100 nM, allowing us to determine the most relevant PPIs and implement a robust competition binding assay. PMID:27438853

  2. Effects of Acute and Chronic Cocaine Administration on Titrating-Delay Matching-to-Sample Performance

    ERIC Educational Resources Information Center

    Kangas, Brian D.; Branch, Marc N.

    2012-01-01

    The effects of cocaine were examined under a titrating-delay matching-to-sample procedure. In this procedure, the delay between sample stimulus offset and comparison stimuli onset adjusts as a function of the subject's performance. Specifically, matches increase the delay and mismatches decrease the delay. Titrated delay values served as the…

  3. Zeta potential response of human erythrocyte membranes to the modulators of Gardos channel activity under low rate β-radiation.

    PubMed

    Zhirnov, V V; Iakovenko, I N; Voitsitskiy, V M; Khyzhnyak, S V; Zubrikova-Chugainova, O G; Gorobetz, V A

    2015-12-01

    Study of human erythrocyte DP response under modification by activators and blockers of the functional state of Ca2+-dependent K+ channels under low rate β-radiation. Erythrocytes were isolated from the donor blood. The zeta potential was computed from the value of the cell electrophoretic mobility. The investigated drugs preliminary introduced in cellular suspensions, and then aliquote of 90Sr(NO3)2 solution to get the final activity concentration of 44,4kBq⋅l-1. The radioisotope radiation of 90Sr/90Y (RR, 15 μGy⋅h-1) increases an absolute value of erythrocyte membranes DP (DPab), and its action is reversible. It specifies the effect is mediated by non-ionizing part of the RR. Dibutyril-cAMP dose-independent increases DPab of erythrocyte membranes in the concentration range of 1-100 мкМ, but RR does not amplify this effect. Anaprilin increases dose-independent DPab in concentrations 10 and 100 μМ. The effect of maximal concentration of anaprilin (100 μМ) decreases by RR. Clotrimazol increases DPab of erythrocyte membranes in the concentration range of 0,1-10 μМ relatively control, while its maximal concentration - decreases, and the minimal level does not reliably influence on this index The action of сlotrimazol on DP in concentrations of 10-100 μМ is abolished by RR, and is not changed in the range of 0,1-1,0 μМ. Nitrendipine raises DPab of erythrocyte membranes in all of range of concentrations, and RR amplifies the effect of the drug. 1. There is a threshold of the biological action on cells for the ionizing component of radioisotope radiation determined by efficiency of operation their antioxidant system.2. At dose rates below a threshold, the action of ionizing radiation is mediated by its non-ionizing component, and is reversible, and therefore is determined only in the field of radiation. V. V. Zhirnov, I. N. Iakovenko, V.M. Voitsitskiy, S. V. Khyzhnyak, О. G. Zubrikova-Chugainova, V.A. Gorobetz.

  4. Multi-complexity measures of heart rate variability and the effect of vasopressor titration: a prospective cohort study of patients with septic shock.

    PubMed

    Brown, Samuel M; Sorensen, Jeffrey; Lanspa, Michael J; Rondina, Matthew T; Grissom, Colin K; Shahul, Sajid; Mathews, V J

    2016-10-10

    Septic shock is a common and often devastating syndrome marked by severe cardiovascular dysfunction commonly managed with vasopressors. Whether markers of heart rate complexity before vasopressor up-titration could be used to predict success of the up-titration is not known. We studied patients with septic shock requiring vasopressor, newly admitted to the intensive care unit. We measured the complexity of heart rate variability (using the ratio of fractal exponents from detrended fluctuation analysis) in the 5 min before all vasopressor up-titrations in the first 24 h of an intensive care unit (ICU) admission. A successful up-titration was defined as one that did not require further up-titration (or decrease in mean arterial pressure) for 60 min. We studied 95 patients with septic shock, with a median APACHE II of 27 (IQR: 20-37). The median number of up-titrations, normalized to 24 h, was 12.2 (IQR: 8-17) with a maximum of 49. Of the up-titrations, the median proportion of successful interventions was 0.28 (IQR: 0.12-0.42). The median of mean arterial pressure (MAP) at the time of a vasopressor up-titration was 66 mmHg; the average infusion rate of norepinephrine at the time of an up-titration was 0.11 mcg/kg/min. The ratio of fractal exponents was not associated with successful up-titration on univariate or multivariate regression. On exploratory secondary analyses, however, the long-term fractal exponent was associated (p = 0.003) with success of up-titration. Independent of heart rate variability, MAP was associated (p < 0.001) with success of vasopressor up-titration, while neither Sequential Organ Failure Assessment (SOFA) nor Acute Physiology and Chronic Health Evaluation II (APACHE II) score was associated with vasopressor titration. Only a third of vasopressor up-titrations were successful among patients with septic shock. MAP and the long-term fractal exponent were associated with success of up-titration. These two, complementary variables

  5. Evaluation of synergistic effects of resynchronization therapy and a β-blocker up-titration strategy based on a predefined patient-management program: the RESTORE study.

    PubMed

    Palmisano, Pietro; Ammendola, Ernesto; D'Onofrio, Antonio; Accogli, Michele; Calò, Leonardo; Ruocco, Antonio; Rapacciuolo, Antonio; Del Giorno, Giuseppe; Bianchi, Valter; Malacrida, Maurizio; Valsecchi, Sergio; Gronda, Edoardo

    2015-01-01

    Prior studies have suggested that a substantial number of eligible heart failure (HF) patients fail to receive β-blocker therapy, or receive it at a suboptimal dose. The aim of this study is to assess the benefit of a predefined management program designed for β-blocker up-titration, evaluating the synergistic effect of cardiac resynchronization therapy (CRT) and β-blockers in a HF population. The Resynchronization Therapy and β-Blocker Titration (RESTORE) study is a prospective, case-control, multicenter cohort study designed to test the hypothesis that a β-blocker up-titration strategy based on a predefined management program maximizes the beneficial effect of CRT, increasing the number of patients reaching the target dose of β-blockers and improving their clinical outcome. All study patients receive an implantable defibrillator for CRT delivery in accordance with current guidelines. Enrollments started in December 2011 and are scheduled to end in December 2014. Approximately 250 consecutive patients will be prospectively enrolled in 6 Italian centers and followed up for 24 months after implantation. The primary endpoint is to demonstrate that CRT may allow titration of β-blockers until the optimal dose, or at least to the effective dose, in patients with HF. This study might provide important information about the benefit of a predefined management program for β-blocker up-titration in patients receiving CRT. Moreover, assessment of health-care utilization and the consumption of resources will allow estimating the potential utility of remote monitoring by means of an automated telemedicine system in facilitating the titration of β-blockers in comparison with a standard in-hospital approach. © 2015 Wiley Periodicals, Inc.

  6. Report of a patient chewing fentanyl patches who was titrated onto methadone

    PubMed Central

    Dale, Eric; Ashby, Fleur; Seelam, Kalyan

    2009-01-01

    This case report discusses the clinical presentation and management of a patient presenting to substance misuse services reporting chewing fentanyl patches in addition to wearing them transdermally. The patient was successfully titrated onto methadone 30 mg. Only one previously reported case of an individual chewing fentanyl patches was found in the literature; no case reports were found where treatment involved titrating the patient onto methadone. The pharmacology and illicit use of fentanyl are also considered. PMID:22114625

  7. Feasibility and Association of Neurohumoral Blocker Up-titration After Cardiac Resynchronization Therapy.

    PubMed

    Martens, Pieter; Verbrugge, Frederik H; Nijst, Petra; Bertrand, Philippe B; Dupont, Matthias; Tang, Wilson H; Mullens, Wilfried

    2017-08-01

    Cardiac resynchronization therapy (CRT) improves mortality and morbidity on top of optimal medical therapy in heart failure with reduced ejection fraction (HFrEF). This study aimed to elucidate the association between neurohumoral blocker up-titration after CRT implantation and clinical outcomes. Doses of angiotensin-converting enzyme inhibitors (ACE-Is), angiotensin receptor blockers (ARBs), and beta-blockers were retrospectively evaluated in 650 consecutive CRT patients implanted from October 2008 to August 2015 and followed in a tertiary multidisciplinary CRT clinic. All 650 CRT patients were on a maximal tolerable dose of ACE-I/ARB and beta-blocker at the time of CRT implantation. However, further up-titration was successful in 45.4% for ACE-I/ARB and in 56.8% for beta-blocker after CRT-implantation. During a mean follow-up of 37 ± 22 months, a total of 139 events occurred for the combined end point of heart failure admission and all-cause mortality. Successful, versus unsuccessful, up-titration was associated with adjusted hazard ratios of 0.537 (95% confidence interval 0.316-0.913; P = .022) for ACE-I/ARB and 0.633 (0.406-0.988; P = .044) for beta-blocker on the combined end point heart failure admission and all-cause mortality. Patients in the up-titration group exhibited a similar risk for death or heart failure admission as patients treated with the maximal dose (ACE-I/ARB: P = .133; beta-blockers: P = .709). After CRT, a majority of patients are capable of tolerating higher dosages of neurohumoral blockers. Up-titration of neurohumoral blockers after CRT implantation is associated with improved clinical outcomes, similarly to patients treated with the guideline-recommended target dose at the time of CRT implantation. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. A new titration system of a novel split-type superconducting magnet NMR spectrometer.

    PubMed

    Kitagawa, Isao; Tanaka, Hideki; Okada, Michiya; Kitaguchi, Hitoshi; Kohzuma, Takamitsu

    2008-12-01

    A new titration system for studying protein-ligand interactions has been developed. In this system, the sample solution is circulated in the route formed by an access path in a split superconducting magnet to maintain a constant protein concentration during the titration experiments. A concentration-control procedure for the ligand/protein ratio is devised, and the ligand/protein ratio is well controlled by this apparatus.

  9. Application of cause-and-effect analysis to potentiometric titration.

    PubMed

    Kufelnicki, A; Lis, S; Meinrath, G

    2005-08-01

    A first attempt has been made to interpret physicochemical data from potentiometric titration analysis in accordance with the complete measurement-uncertainty budget approach (bottom-up) of ISO and Eurachem. A cause-and-effect diagram is established and discussed. Titration data for arsenazo III are used as a basis for this discussion. The commercial software Superquad is used and applied within a computer-intensive resampling framework. The cause-and-effect diagram is applied to evaluation of seven protonation constants of arsenazo III in the pH range 2-10.7. The data interpretation is based on empirical probability distributions and their analysis by second-order correct confidence estimates. The evaluated data are applied in the calculation of a speciation diagram including uncertainty estimates using the probabilistic speciation software Ljungskile.

  10. Catalytic thermometric titrations in non-aqueous solvents by coulometrically generated titrant.

    PubMed

    Vajgand, V J; Gaál, F F; Brusin, S S

    1970-05-01

    Catalytic thermometric titrations have been developed for tertiary amines and salts of organic acids in acetic and propionic anhydride with titrant coulometrically generated at a mercury and/or platinum anode, hydroquinone being added to the solution titrated if the platinum anode is used. The results obtained are compared with those obtained by coulometric titration with the end-point detected either photometrically or potentiometrically. On a élaboré des titrages thermométriques catalytiques pour les amines tertiaires et les sels d'acides organiques en anhydrides aétique et propionique avec l'agent de titrage engendré coulométriquement sur une anode de mercure et/ou platine, de l'hydroquinone étant ajoutée à la solution titrée si l'on emploie l'anode de platine. Les résultats obtenus sont comparés avec ceux obtenus par titrage coulométrique avec le point de fin de réaction détecté soit photométriquement soit potentioétriquement.

  11. Isothermal Titration Calorimetry Can Provide Critical Thinking Opportunities

    ERIC Educational Resources Information Center

    Moore, Dale E.; Goode, David R.; Seney, Caryn S.; Boatwright, Jennifer M.

    2016-01-01

    College chemistry faculties might not have considered including isothermal titration calorimetry (ITC) in their majors' curriculum because experimental data from this instrumental method are often analyzed via automation (software). However, the software-based data analysis can be replaced with a spreadsheet-based analysis that is readily…

  12. Determination of arsenate and organic arsenic via potentiometric titration of its heteropoly anions.

    PubMed

    Metelka, R; Slavíková, S; Vytras, K

    2002-08-16

    Determination of arsenate based on its conversion to molybdoarsenate heteropoly anions followed by potentiometric titration is described. The titration is realized on the ion-pairing principle using cetylpyridinium chloride (or an analogous titrant containing a lipophilic cation), and is monitored by a carbon paste electrode, although other liquid-polymeric membrane-based electrodes can also be used. Calibration plots of the titrant end-point consumption versus concentration of arsenic were constructed and used to evaluate the content of arsenic in aqueous samples. The method could be applied in the analyses of samples with quite low arsenic content (amounts approximately 10 mug As in 50 cm(3) could be titrated). Organic arsenic was determined analogously after the Schöniger combustion of the sample and conversion of its arsenic to arsenate.

  13. High-throughput Titration of Luciferase-expressing Recombinant Viruses

    PubMed Central

    Garcia, Vanessa; Krishnan, Ramya; Davis, Colin; Batenchuk, Cory; Le Boeuf, Fabrice; Abdelbary, Hesham; Diallo, Jean-Simon

    2014-01-01

    Standard plaque assays to determine infectious viral titers can be time consuming, are not amenable to a high volume of samples, and cannot be done with viruses that do not form plaques. As an alternative to plaque assays, we have developed a high-throughput titration method that allows for the simultaneous titration of a high volume of samples in a single day. This approach involves infection of the samples with a Firefly luciferase tagged virus, transfer of the infected samples onto an appropriate permissive cell line, subsequent addition of luciferin, reading of plates in order to obtain luminescence readings, and finally the conversion from luminescence to viral titers. The assessment of cytotoxicity using a metabolic viability dye can be easily incorporated in the workflow in parallel and provide valuable information in the context of a drug screen. This technique provides a reliable, high-throughput method to determine viral titers as an alternative to a standard plaque assay. PMID:25285536

  14. Trace analysis of acids and bases by conductometric titration with multiparametric non-linear regression.

    PubMed

    Coelho, Lúcia H G; Gutz, Ivano G R

    2006-03-15

    A chemometric method for analysis of conductometric titration data was introduced to extend its applicability to lower concentrations and more complex acid-base systems. Auxiliary pH measurements were made during the titration to assist the calculation of the distribution of protonable species on base of known or guessed equilibrium constants. Conductivity values of each ionized or ionizable species possibly present in the sample were introduced in a general equation where the only unknown parameters were the total concentrations of (conjugated) bases and of strong electrolytes not involved in acid-base equilibria. All these concentrations were adjusted by a multiparametric nonlinear regression (NLR) method, based on the Levenberg-Marquardt algorithm. This first conductometric titration method with NLR analysis (CT-NLR) was successfully applied to simulated conductometric titration data and to synthetic samples with multiple components at concentrations as low as those found in rainwater (approximately 10 micromol L(-1)). It was possible to resolve and quantify mixtures containing a strong acid, formic acid, acetic acid, ammonium ion, bicarbonate and inert electrolyte with accuracy of 5% or better.

  15. An interstellar cloud density from Copernicus observations of CO in the spectrum of Zeta Ophiuchi

    NASA Technical Reports Server (NTRS)

    Smith, A. M.; Stecher, T. P.; Krishna Swamy, K. S.

    1978-01-01

    Interstellar CO absorption bands in Copernicus spectra of Zeta Oph have been studied. Absorption profiles, computed under the assumption that excitation is due to collisions with H2 molecules and interaction with the 3-K background radiation field, were fitted to the reduced data of nine bands. When a gas kinetic temperature of 56 K is assumed, the best-fit condition implies a hydrogen-nucleus density of 120 per cu cm, a CO column density of 1.2 by 10 to the 15th power per sq cm, and a radial-velocity dispersion of 0.9 km/s. The relevance of these results to existing ideas concerning the Zeta Oph interstellar clouds is discussed. It is suggested that the strongest interstellar component is not circumstellar in origin but is instead part of a supernova remnant. Simple calculations are made to establish the plausibility of the supernova-remnant identification. This suggestion is also supported by Heiles's (1976) 21-cm pictures.

  16. Advanced titration to treat a floppy epiglottis in selective upper airway stimulation.

    PubMed

    Heiser, Clemens

    2016-09-01

    The following report presents a case of a patient with high residual apnea-hypopnea index at 6 months following implantation of an upper airway stimulation device who improved significantly after advanced titration via drug-induced sedated endoscopy by changing the electrode configuration for stimulation from bipolar to monopolar. This case demonstrates the utility of postsurgical advanced titration to optimize programming settings for improved clinical outcomes. Laryngoscope, 126:S22-S24, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Coulometric thermometric titration of halides in molten calcium nitrate tetrahydrate.

    PubMed

    Zsigrai, I J; Bartusz, D B

    1983-01-01

    A method for coulometric thermometric precipitation titrations of chloride, bromide and iodide in molten calcium nitrate tetrahydrate at 55 degrees with coulometrically generated silver ions has been developed. The change in temperature during the titration is followed with the aid of a thermistor bridge coupled to a recorder. To minimize the temperature effect of the passage of current through the melt, two thermistors are connected in opposition in the bridge, with one in the anodic and the other in the cathodic cell compartment. Amounts of 62-80 mumole of halide have been determined with relative error below 0.4% and relative standard deviation less than 2.7%. The relative error in determination of 40 mumole of iodide was + 2%.

  18. Interstellar detection of the intersystem line Si II lambda 2335 toward zeta Ophiuchi

    NASA Technical Reports Server (NTRS)

    Cardelli, Jason A.; Sofia, Ulysses J.; Savage, Blair D.; Keenan, Francis P.; Dufton, Philip L.

    1994-01-01

    We report on the detection of the weak intersystem transistion of Si II lambda 2335 A in the sight line toward zeta Oph using the Ech-B mode (3.5 km/s resolution) of the Goddard High Resolution Spectrograph. The high-quality spectrum is characterized by an empirically measured signal-to-noise of 450, in excellent agreement with that expected from photon-statistics. The measured equivalent width of the Si II line is W(sub lambda) = 0.48 +/- 0.12 mA. Using the new experimental f-value of Calamai, Smith, and Bergeson, we find a Si II column density of 2.34 (+/- 0.58) x 10(exp 15) atoms/sq cm and (Si/H)(sub zeta Oph) = 1.78 (+/- 0.44) x 10(exp -6) for the principal absorbing component(s) at v(sub sun) approx. = -15 km/s. Analysis of the Si II lambda 1808 absorption over the same velocity range using the new experimental f-value of Bergeson & Lawler yields a column density (corrected for saturation) that is consistent within the weak line errors and confirms the relative accuracies of these new f-values. Furthermore, these results indicate that accurate abundances can now be derived for Si II, particularly from the weak Si II lambda 2335 A since it is free of saturation effects. For the zeta Oph v(sub sun) approx. = -15 km/s component(s), we find that greater than 95% of the available cosmic abundance (i.e. the 1989 meteoritic abundances of Anders & Grevesse) of Mg, Fe, and Si is 'missing' from the gas phase and is presumably locked up in the dust. These elements are present in the dust grains in ratios of Fe/Si approximately equals 0.9 and Mg/Si approximately equals 1.1, consistent with the ratio of their cosmic abundances. These ratios are in sharp contrast to more diffuse clouds like those seen toward the high-latitude halo star HD 93521 where in the dust Fe/Si approximately equals 1.8 and Mg/Si approximately equals 2.1.

  19. HD 93521, zeta Ophiuchi, and the effects of rapid rotation on the atmospheres and winds of 09.5 V stars

    NASA Technical Reports Server (NTRS)

    Massa, Derck

    1995-01-01

    Both low- and high-resolution IUE spectra of the rapidly rotating 09.5 V stars HD 93521 and zeta Oph are used to develop a coherent picture of the effects of rapid rotation on the atmospheres and winds of late, main-sequence O stars. The observational consequences are by far the strongest on HD 93521, most likely because it is being viewed nearly equator-on. In particular, it is shown that HD 93521 (1) a much smaller UV optical flux ratio than expected, (2) UV photospheric lines indicative of a BO supergiant, (3) an abnormally strong N v wind doublet, and (4) wind profiles suggesting that its wind has latitudinally dependent properties. Because HD 93521 has a larger observed v sin i than zeta Oph and yet its H-alpha emission is no stronger than in zeta Oph, it is speculated that zeta Oph actually rotates as fast or faster than HD 93521, but has a smaller sin i. Because zeta Oph is significantly reddened, nothing can be determined about its intrinsic UV energy distribution. However, it is shown that its UV photospheric lines are a bit peculiar and that its C IV and N V wind doublets are abnormally strong and have unusual profiles. The C IV profile agrees with models of a rotationally distorted wind similar to the one in HD 93521, except viewed at an angle i approximately 60 deg-80 deg. The spectral peculiarities of both stars are attributed to the combined effects of gravity darkening of their atmospheres and rotational distortion of their winds. The differences between their spectra are interpreted as the result of being viewed at different inclination angles. Because of the gravity darkening, atmospheric analyses of either star based on single temperature and surface gravity model atmospheres are probably unreliable. Finally, I describe how different effects conspire to make the spectroscopic signatures of gravity darkening so pronounced at 09.5 V.

  20. Potentiometric/turbidometric titration of antiperspirant actives.

    PubMed

    Johnston, Clifford T; Hem, Stanley L; Guenin, Eric; Mattai, Jairajh; Afflito, John

    2003-01-01

    A titration procedure that simultaneously monitors the pH and turbidity of an antiperspirant solution during neutralization with sodium hydroxide was developed to characterize antiperspirant actives. Aluminum chloride, aluminum chlorohydrate (ACH), and aluminum zirconium glycine complex (AZG) gave distinctive pH/turbidity profiles. The activated forms of aluminum chlorohydrate (ACH') and aluminum zirconium glycine complex (AZG') produced more turbidity than the non-activated forms. On an equimolar basis, AZG' produced more turbidity than any of the antiperspirant actives tested.

  1. Spectroscopic study on variations in illite surface properties after acid-base titration.

    PubMed

    Liu, Wen-xin; Coveney, R M; Tang, Hong-xiao

    2003-07-01

    FT-IR, Raman microscopy, XRD, 29Si and 27Al MAS NMR, were used to investigate changes in surface properties of a natural illite sample after acid-base potentiometric titration. The characteristic XRD lines indicated the presence of surface Al-Si complexes, preferable to Al(OH)3 precipitates. In the microscopic Raman spectra, the vibration peaks of Si-O and Al-O bonds diminished as a result of treatment with acid, then increased after hydroxide back titration. The varied ratio of signal intensity between (IV)Al and (VI)Al species in 27Al MAS NMR spectra, together with the stable BET surface area after acidimetric titration, suggested that edge faces and basal planes in the layer structure of illite participated in dissolution of structural components. The combined spectroscopic evidence demonstrated that the reactions between illite surfaces and acid-leaching silicic acid and aluminum ions should be considered in the model description of surface acid-base properties of the aqueous illite.

  2. A Computer-Based Simulation of an Acid-Base Titration

    ERIC Educational Resources Information Center

    Boblick, John M.

    1971-01-01

    Reviews the advantages of computer simulated environments for experiments, referring in particular to acid-base titrations. Includes pre-lab instructions and a sample computer printout of a student's use of an acid-base simulation. Ten references. (PR)

  3. Analyte preconcentration in nanofluidic channels with nonuniform zeta potential

    NASA Astrophysics Data System (ADS)

    Eden, A.; McCallum, C.; Storey, B. D.; Pennathur, S.; Meinhart, C. D.

    2017-12-01

    It is well known that charged analytes in the presence of nonuniform electric fields concentrate at locations where the relevant driving forces balance, and a wide range of ionic stacking and focusing methods are commonly employed to leverage these physical mechanisms in order to improve signal levels in biosensing applications. In particular, nanofluidic channels with spatially varying conductivity distributions have been shown to provide increased preconcentration of charged analytes due to the existence of a finite electric double layer (EDL), in which electrostatic attraction and repulsion from charged surfaces produce nonuniform transverse ion distributions. In this work, we use numerical simulations to show that one can achieve greater levels of sample accumulation by using field-effect control via wall-embedded electrodes to tailor the surface potential heterogeneity in a nanochannel with overlapped EDLs. In addition to previously demonstrated stacking and focusing mechanisms, we find that the coupling between two-dimensional ion distributions and the axial electric field under overlapped EDL conditions can generate an ion concentration polarization interface in the middle of the channel. Under an applied electric field, this interface can be used to concentrate sample ions between two stationary regions of different surface potential and charge density. Our numerical model uses the Poisson-Nernst-Planck system of equations coupled with the Stokes equation to demonstrate the phenomenon, and we discuss in detail the driving forces behind the predicted sample enhancement. The numerical velocity and salt concentration profiles exhibit good agreement with analytical results from a simplified one-dimensional area-averaged model for several limiting cases, and we show predicted amplification ratios of up to 105.

  4. Aquaporin-4 antibody titration in NMO patients treated with rituximab: A retrospective study.

    PubMed

    Valentino, Paola; Marnetto, Fabiana; Granieri, Letizia; Capobianco, Marco; Bertolotto, Antonio

    2017-03-01

    We undertook an observational retrospective study to investigate the usefulness of aquaporin-4 (AQP4) antibodies (Ab) titration in the management of patients with neuromyelitis optica (NMO) treated with rituximab (RTX) by studying (1) the correlation between AQP4-Ab titer and disease activity, (2) the influence of RTX on antibody levels, and (3) the association between AQP4-Ab levels and responsiveness to RTX. A cell-based assay was used for AQP4-Ab titration in 322 serum samples from 7 patients with NMO treated with RTX (median follow-up 65 months), according to a treatment-to-target approach. Serum samples were collected every month following standardized procedures. (1) In group analysis, AQP4-Ab titers correlated with the disease activity, showing higher titers during and preceding relapses than during remission. However, in individual analysis, an increase in AQP4-Ab titers and CD19+ B cells did not always precede a relapse. (2) A reduction of AQP4-Ab titers in the short-term and long-term period was observed during RTX treatment. (3) Reduction of AQP4-Ab titers was observed in responder patients both 3 months after RTX infusion and in the long-term follow-up. In one nonresponder patient, AQP4-Ab levels never decreased during the treatment period. Titration of AQP4-Abs could be useful in the clinical management of patients with NMO treated with RTX: titration before each reinfusion and 3 months after each reinfusion may provide information about responsiveness to RTX. Although a relationship among AQP4-Ab levels, disease activity, and response to RTX was observed, the usefulness of AQP4-Ab titration to predict relapses is limited.

  5. Determination of sulfur compounds in hydrotreated transformer base oil by potentiometric titration.

    PubMed

    Chao, Qiu; Sheng, Han; Cheng, Xingguo; Ren, Tianhui

    2005-06-01

    A method was developed to analyze the distribution of sulfur compounds in model sulfur compounds by potentiometric titration, and applied to analyze hydrotreated transformer base oil. Model thioethers were oxidized to corresponding sulfoxides by tetrabutylammonium periodate and sodium metaperiodate, respectively, and the sulfoxides were titrated by perchloric acid titrant in acetic anhydride. The contents of aliphatic thioethers and total thioethers were then determined from that of sulfoxides in solution. The method was applied to determine the organic sulfur compounds in hydrotreated transformer base oil.

  6. Acid-base properties of the alumina surface: influence of the titration procedures on the microcalorimetric results.

    PubMed

    Morel, Jean-Pierre; Marmier, Nicolas; Hurel, Charlotte; Morel-Desrosiers, Nicole

    2009-10-01

    The enthalpy changes associated with the protonation and deprotonation of an alumina surface have been determined on the basis of microcalorimetry experiments and acid-base potentiometric titrations at 25 degrees C. It has been shown that the results may vary significantly according to the experimental procedure. In order to do so, the potentiometric and microcalorimetric titrations have been carried out first from an acidic pH to basic pH and second from a pH near the pH(zpc) of alumina to acidic or basic pH. It has been demonstrated that the pK(a) values deduced from the potentiometric titrations are the same whatever the experimental protocol whereas the only way to obtain meaningful enthalpies of proton exchange is to carry out microcalorimetric titrations by starting around the point of zero charge.

  7. Preliminary X-ray crystallographic analysis of glutathione transferase zeta 1 (GSTZ1a-1a)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boone, Christopher D.; Zhong, Guo; Smeltz, Marci

    2014-01-21

    Crystals of glutathione transferase zeta 1 were grown and shown to diffract X-rays to 3.1 Å resolution. They belonged to space group P1, with unit-cell parameters a = 42.0, b = 49.6, c = 54.6 Å, α = 82.9, β = 69.9, γ = 73.4°.

  8. Titration of individual strains in trivalent live-attenuated influenza vaccine without neutralization.

    PubMed

    Sirinonthanawech, Naraporn; Surichan, Somchaiya; Namsai, Aphinya; Puthavathana, Pilaipan; Auewarakul, Prasert; Kongchanagul, Alita

    2016-11-01

    Formulation and quality control of trivalent live-attenuated influenza vaccine requires titration of infectivity of individual strains in the trivalent mix. This is usually performed by selective neutralization of two of the three strains and titration of the un-neutralized strain in cell culture or embryonated eggs. This procedure requires standard sera with high neutralizing titer against each of the three strains. Obtaining standard sera, which can specifically neutralize only the corresponding strain of influenza viruses and is able to completely neutralize high concentration of virus in the vaccine samples, can be a problem for many vaccine manufacturers as vaccine stocks usually have very high viral titers and complete neutralization may not be obtained. Here an alternative approach for titration of individual strain in trivalent vaccine without the selective neutralization is presented. This was done by detecting individual strains with specific antibodies in an end-point titration of a trivalent vaccine in cell culture. Similar titers were observed in monovalent and trivalent vaccines for influenza A H3N2 and influenza B strains, whereas the influenza A H1N1 strain did not grow well in cell culture. Viral interference among the vaccine strains was not observed. Therefore, providing that vaccine strains grow well in cell culture, this assay can reliably determine the potency of individual strains in trivalent live-attenuated influenza vaccines. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial

    PubMed Central

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; GrÜnwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2014-01-01

    Summary Background Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. Methods In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. This ongoing trial is registered with ClinicalTrials.gov, number NCT00835978. Findings Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40–67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22–48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49–70) of non

  10. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial.

    PubMed

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; Grünwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2013-11-01

    Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40-67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22-48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49-70) of non-randomised patients achieved an objective response. Common grade 3 or worse, all-causality adverse events in treated patients

  11. Equivalence-point electromigration acid-base titration via moving neutralization boundary electrophoresis.

    PubMed

    Yang, Qing; Fan, Liu-Yin; Huang, Shan-Sheng; Zhang, Wei; Cao, Cheng-Xi

    2011-04-01

    In this paper, we developed a novel method of acid-base titration, viz. the electromigration acid-base titration (EABT), via a moving neutralization boundary (MNR). With HCl and NaOH as the model strong acid and base, respectively, we conducted the experiments on the EABT via the method of moving neutralization boundary for the first time. The experiments revealed that (i) the concentration of agarose gel, the voltage used and the content of background electrolyte (KCl) had evident influence on the boundary movement; (ii) the movement length was a function of the running time under the constant acid and base concentrations; and (iii) there was a good linearity between the length and natural logarithmic concentration of HCl under the optimized conditions, and the linearity could be used to detect the concentration of acid. The experiments further manifested that (i) the RSD values of intra-day and inter-day runs were less than 1.59 and 3.76%, respectively, indicating similar precision and stability in capillary electrophoresis or HPLC; (ii) the indicators with different pK(a) values had no obvious effect on EABT, distinguishing strong influence on the judgment of equivalence-point titration in the classic one; and (iii) the constant equivalence-point titration always existed in the EABT, rather than the classic volumetric analysis. Additionally, the EABT could be put to good use for the determination of actual acid concentrations. The experimental results achieved herein showed a new general guidance for the development of classic volumetric analysis and element (e.g. nitrogen) content analysis in protein chemistry. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Estimation of uncertainty in pKa values determined by potentiometric titration.

    PubMed

    Koort, Eve; Herodes, Koit; Pihl, Viljar; Leito, Ivo

    2004-06-01

    A procedure is presented for estimation of uncertainty in measurement of the pK(a) of a weak acid by potentiometric titration. The procedure is based on the ISO GUM. The core of the procedure is a mathematical model that involves 40 input parameters. A novel approach is used for taking into account the purity of the acid, the impurities are not treated as inert compounds only, their possible acidic dissociation is also taken into account. Application to an example of practical pK(a) determination is presented. Altogether 67 different sources of uncertainty are identified and quantified within the example. The relative importance of different uncertainty sources is discussed. The most important source of uncertainty (with the experimental set-up of the example) is the uncertainty of pH measurement followed by the accuracy of the burette and the uncertainty of weighing. The procedure gives uncertainty separately for each point of the titration curve. The uncertainty depends on the amount of titrant added, being lowest in the central part of the titration curve. The possibilities of reducing the uncertainty and interpreting the drift of the pK(a) values obtained from the same curve are discussed.

  13. The Mobile Insulin Titration Intervention (MITI) for Insulin Adjustment in an Urban, Low-Income Population: Randomized Controlled Trial.

    PubMed

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-07-17

    Diabetes patients are usually started on a low dose of insulin and their dose is adjusted or "titrated" according to their blood glucose levels. Insulin titration administered through face-to-face visits with a clinician can be time consuming and logistically burdensome for patients, especially those of low socioeconomic status (SES). Given the wide use of mobile phones among this population, there is the potential to use short message service (SMS) text messaging and phone calls to perform insulin titration remotely. The goals of this pilot study were to (1) evaluate if our Mobile Insulin Titration Intervention (MITI) intervention using text messaging and phone calls was effective in helping patients reach their optimal insulin glargine dose within 12 weeks, (2) assess the feasibility of the intervention within our clinic setting and patient population, (3) collect data on the cost savings associated with the intervention, and (4) measure patient satisfaction with the intervention. This was a pilot study evaluating an intervention for patients requiring insulin glargine titration in the outpatient medical clinic of Bellevue Hospital Center in New York City. Patients in the intervention arm received weekday SMS text messages from a health management platform requesting their fasting blood glucose values. The clinic's diabetes nurse educator monitored the texted responses on the platform website each weekday for alarm values. Once a week, the nurse reviewed the glucose values, consulted the MITI titration algorithm, and called patients to adjust their insulin dose. Patients in the usual care arm continued to receive their standard clinic care for insulin titration. The primary outcome was whether a patient reached his/her optimal insulin glargine dose within 12 weeks. A total of 61 patients consented and were randomized into the study. A significantly greater proportion of patients in the intervention arm reached their optimal insulin glargine dose than patients in

  14. Developing a multipoint titration method with a variable dose implementation for anaerobic digestion monitoring.

    PubMed

    Salonen, K; Leisola, M; Eerikäinen, T

    2009-01-01

    Determination of metabolites from an anaerobic digester with an acid base titration is considered as superior method for many reasons. This paper describes a practical at line compatible multipoint titration method. The titration procedure was improved by speed and data quality. A simple and novel control algorithm for estimating a variable titrant dose was derived for this purpose. This non-linear PI-controller like algorithm does not require any preliminary information from sample. Performance of this controller is superior compared to traditional linear PI-controllers. In addition, simplification for presenting polyprotic acids as a sum of multiple monoprotic acids is introduced along with a mathematical error examination. A method for inclusion of the ionic strength effect with stepwise iteration is shown. The titration model is presented with matrix notations enabling simple computation of all concentration estimates. All methods and algorithms are illustrated in the experimental part. A linear correlation better than 0.999 was obtained for both acetate and phosphate used as model compounds with slopes of 0.98 and 1.00 and average standard deviations of 0.6% and 0.8%, respectively. Furthermore, insensitivity of the presented method for overlapping buffer capacity curves was shown.

  15. [Photometric micro-titration model of DPPH radicals scavenging activity and its application].

    PubMed

    Gao, Yun-tao; Wei, Wei; Ye, Li-qing; Li, Xiao-fen; Liu, Ping; Zhang, Hong-jiao; Yang, Lu; Yu, Jiao-jiao; Cha, Jia-wei

    2015-02-01

    In the present paper, the stoichiometric ratio (R) for the interreaction of DPPH radicals with the antoxidant was employed as a evaluation index for DPPH radicals scavenging activity of antioxidants. This evaluation index was related only with the stoichiometric relationship between DPPH radicals and the antioxidant, not the relationship with the initial DPPH amount and the volume of sample, which could offer a solution for the problem of poor comparability of EC50 under different conditions. A novel photometric micro-titration method was proposed for the determination of the stoichiometric ratio (R) for the interreaction of DPPH radicals with the antoxidant. The titration equation was established based on the absorbance difference (deltaA) of DPPH radicals in the titration process and the added amount of antoxidant. The stoichiometric ratio (R) for the reaction of DPPH radicals with the addition amount of antoxidant was determined by the titration equation obtained, while, the DPPH median elimination concentration (EC50) of antoxidant can be calculated by the stoichiometric ratio (R). The above photometric micro-titration model was verified using rutin as DPPH radicals scavenger. As experiment results, the stoichiometric ratio (R) of DPPH radicals to rutin was determined to be in the range of 1.817-1.846. The calculated value of EC50 was 1.196 x 10(-3), 2.392 x 10(-3), 4.819 x 10(-3) and 7.292 x 10(-3) mg x mL(-1) for 1.12 x 10(-7), 2.24 x 10(-7), 4.48 x 10(-7) and 6.72 x 10(-7) mol of the additon amount of DPPH radicals, respectively. The proposed method has better precision and reliability with smaller amount of sample than conventional method. While, the obtained stoichiometric ratio value (R) of rutin was employed to calculate the rutin median elimination concentration for DPPH EC50) according to the conditions as reported in the literatures, and the calculated results were consistent with that reported in the literatures.

  16. Titrating Oxygen Requirements During Exercise: Evaluation of a Standardized Single Walk Test Protocol.

    PubMed

    Giovacchini, Coral X; Mathews, Anne M; Lawlor, Brian R; MacIntyre, Neil R

    2018-04-01

    Oxygen supplementation for exercise-induced hypoxemia is a common clinical practice that improves exercise tolerance. However, we know of no standardized exercise oxygen titration protocol using a single walk test. We report our experience with a protocol developed in our laboratory. Our protocol is based on the 6-min walk test (6MWT). Pulse oximetry readings (oxygen saturation [Spo 2 ]) are monitored, and supplemental oxygen is added in 2 L/min increments to keep Spo 2 > 88%. This continues for at least 6 min of walking with the Spo 2 remaining > 88% for at least 3 min. The records of consecutive patients over 4 months undergoing this procedure were reviewed for test performance, oxygen titration results, and adverse events. Two hundred twenty-two patients were tested; only two prematurely terminated the protocol because of intractable dyspnea. One hundred fifty-six patients (38%) required oxygen supplementation, with the first titration most commonly occurring between 1 and 2 min of walking. Nine of the patients had the first titration after 5 min of walking. The average test duration was 7 min (maximum, 15 min). The average number of titrations was 2.2 (maximum six). Sixteen patients could not maintain Spo 2 > 88% for 3 min despite administration of 15 L/min of supplemental oxygen (maximal dose). Our protocol was easily performed as a modification of a standard 6MWT with no serious adverse events. Because it is based on a widely accepted measurement of functional capabilities, and because it determined a stable final oxygen dose for ≥ 3 min of walking in most patients, we believe this protocol can be easily adapted for clinical use. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  17. Impact of systolic blood pressure on the safety and tolerability of initiating and up-titrating sacubitril/valsartan in patients with heart failure and reduced ejection fraction: insights from the TITRATION study.

    PubMed

    Senni, Michele; McMurray, John J V; Wachter, Rolf; McIntyre, Hugh F; Anand, Inder S; Duino, Vincenzo; Sarkar, Arnab; Shi, Victor; Charney, Alan

    2018-03-01

    The TITRATION trial investigated two strategies to initiate and up-titrate sacubitril/valsartan (LCZ696) to the same target dose, over a condensed (3-week) or conservative (6-week) period, in patients with heart failure with reduced ejection fraction (HFrEF) and systolic blood pressure (SBP) of ≥100 mmHg. This post hoc analysis examined the relationship between baseline SBP at screening and achievement of the target dose of sacubitril/valsartan of 97 mg/103 mg (also termed 'LCZ696 200 mg') twice per day during the study. Patients (n = 498) were categorized in four groups based on SBP at screening: 100-110 mmHg (n = 70); 111-120 mmHg (n = 93); 121-139 mmHg (n = 168) and ≥140 mmHg (n = 167). Overall, 72.7%, 76.1%, 85.6% and 82.9%, respectively, of patients in these SBP categories achieved and maintained the target dose of sacubitril/valsartan without down-titration/dose interruption over 12 weeks ('treatment success'). Compared with patients with SBP of 100-110 mmHg, rates of treatment success among patients in the higher SBP groups [111-120 mmHg (P = 0.96); 121-139 mmHg (P = 0.06) and ≥140 mmHg (P = 0.25)] did not differ significantly. A higher percentage of patients with lower SBP (100-110 mmHg) achieved treatment success with gradual up-titration (6 weeks) (∼80%) than with rapid up-titration (∼69%). Similar findings were observed with regard to 'tolerability success' (maintenance of the target dose for at least the final 2 weeks prior to study completion). Hypotension occurred more frequently in patients with lower SBP. The majority of patients (>80%) with SBP of ≥100 mmHg achieved and maintained the target dose of sacubitril/valsartan if the treatment was titrated gradually. These findings suggest that low SBP should not prevent clinicians from considering the initiation of sacubitril/valsartan. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of

  18. Impact of Uniform Methods on Interlaboratory Antibody Titration Variability: Antibody Titration and Uniform Methods.

    PubMed

    Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H

    2017-01-01

    -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.

  19. Titratable acidity of beverages influences salivary pH recovery.

    PubMed

    Tenuta, Livia Maria Andaló; Fernández, Constanza Estefany; Brandão, Ana Carolina Siqueira; Cury, Jaime Aparecido

    2015-01-01

    A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control) were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively) and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and < 0.005 mmols OH- to reach pH 5.5, respectively). Eight volunteers with a normal salivary flow rate and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.

  20. Evaluation of the 5 and 8 pH point titration methods for monitoring anaerobic digesters treating solid waste.

    PubMed

    Vannecke, T P W; Lampens, D R A; Ekama, G A; Volcke, E I P

    2015-01-01

    Simple titration methods certainly deserve consideration for on-site routine monitoring of volatile fatty acid (VFA) concentration and alkalinity during anaerobic digestion (AD), because of their simplicity, speed and cost-effectiveness. In this study, the 5 and 8 pH point titration methods for measuring the VFA concentration and carbonate system alkalinity (H2CO3*-alkalinity) were assessed and compared. For this purpose, synthetic solutions with known H2CO3*-alkalinity and VFA concentration as well as samples from anaerobic digesters treating three different kind of solid wastes were analysed. The results of these two related titration methods were verified with photometric and high-pressure liquid chromatography measurements. It was shown that photometric measurements lead to overestimations of the VFA concentration in the case of coloured samples. In contrast, the 5 pH point titration method provides an accurate estimation of the VFA concentration, clearly corresponding with the true value. Concerning the H2CO3*-alkalinity, the most accurate and precise estimations, showing very similar results for repeated measurements, were obtained using the 8 pH point titration. Overall, it was concluded that the 5 pH point titration method is the preferred method for the practical monitoring of AD of solid wastes due to its robustness, cost efficiency and user-friendliness.

  1. Quantitative Determination of NTA and Other Chelating Agents in Detergents by Potentiometric Titration with Copper Ion Selective Electrode.

    PubMed

    Ito, Sana; Morita, Masaki

    2016-01-01

    Quantitative analysis of nitrilotriacetate (NTA) in detergents by titration with Cu 2+ solution using a copper ion selective electrode was achieved. This method tolerates a wide range of pH and ingredients in detergents. In addition to NTA, other chelating agents, having relatively lower stability constants toward Cu 2+ , were also qualified with sufficient accuracy by this analytical method for model detergent formulations. The titration process was automated by automatic titrating systems available commercially.

  2. Determination of the total acidity in soft drinks using potentiometric sequential injection titration.

    PubMed

    van Staden, J Koos F; Mashamba, M Mulalo G; Stefan, R Raluca I

    2002-12-06

    A potentiometric SI titration system for the determination of total acidity in soft drinks is proposed. The concept is based on the aspiration of the acid soft drink sample between two base zones into a holding coil with the volume of the first base zone twice to that of the second one and channelled by flow reversal through a reaction coil to a potentiometric sensor. A solution of 0.1 mol l(-1) sodium chloride is used as ionic strength adjustment buffer in the carrier stream. The system has been applied to the analysis of some South African soft drinks having a total acidity level of about 0.2-0.3% (w/v). The method has a sample frequency of 45 samples per h with a linear range of 0.1 and 0.6% (w/v). It is easy to use, fully computerised, and gives the results that are comparable to both automated batch titration and manual titration.

  3. Positive zeta potential of a negatively charged semi-permeable plasma membrane

    NASA Astrophysics Data System (ADS)

    Sinha, Shayandev; Jing, Haoyuan; Das, Siddhartha

    2017-08-01

    The negative charge of the plasma membrane (PM) severely affects the nature of moieties that may enter or leave the cells and controls a large number of ion-interaction-mediated intracellular and extracellular events. In this letter, we report our discovery of a most fascinating scenario, where one interface (e.g., membrane-cytosol interface) of the negatively charged PM shows a positive surface (or ζ) potential, while the other interface (e.g., membrane-electrolyte interface) still shows a negative ζ potential. Therefore, we encounter a completely unexpected situation where an interface (e.g., membrane-cytosol interface) that has a negative surface charge density demonstrates a positive ζ potential. We establish that the attainment of such a property by the membrane can be ascribed to an interplay of the nature of the membrane semi-permeability and the electrostatics of the electric double layer established on either side of the charged membrane. We anticipate that such a membrane property can lead to such capabilities of the cell (in terms of accepting or releasing certain kinds of moieties as well regulating cellular signaling) that was hitherto inconceivable.

  4. Improved methylene blue two-phase titration method for determining cationic surfactant concentration in high-salinity brine.

    PubMed

    Cui, Leyu; Puerto, Maura; López-Salinas, José L; Biswal, Sibani L; Hirasaki, George J

    2014-11-18

    The methylene blue (MB) two-phase titration method is a rapid and efficient method for determining the concentrations of anionic surfactants. The point at which the aqueous and chloroform phases appear equally blue is called Epton's end point. However, many inorganic anions, e.g., Cl(-), NO3(-), Br(-), and I(-), can form ion pairs with MB(+) and interfere with Epton's end point, resulting in the failure of the MB two-phase titration in high-salinity brine. Here we present a method to extend the MB two-phase titration method for determining the concentration of various cationic surfactants in both deionized water and high-salinity brine (22% total dissolved solid). A colorless end point, at which the blue color is completely transferred from the aqueous phase to the chloroform phase, is proposed as titration end point. Light absorbance at the characteristic wavelength of MB is measured using a spectrophotometer. When the absorbance falls below a threshold value of 0.04, the aqueous phase is considered colorless, indicating that the end point has been reached. By using this improved method, the overall error for the titration of a permanent cationic surfactant, e.g., dodecyltrimethylammonium bromide, in deionized (DI) water and high-salinity brine is 1.274% and 1.322% with limits of detection (LOD) of 0.149 and 0.215 mM, respectively. Compared to the traditional acid-base titration method, the error of this improved method for a switchable cationic surfactant, e.g., tertiary amine surfactant (Ethomeen C12), is 2.22% in DI water and 0.106% with LOD of 0.369 and 0.439 mM, respectively.

  5. Determination of Acidity Constants by Gradient Flow-Injection Titration

    ERIC Educational Resources Information Center

    Conceicao, Antonio C. L.; Minas da Piedade, Manuel E.

    2006-01-01

    A three-hour laboratory experiment, designed for an advanced undergraduate course in instrumental analysis that illustrates the application of the gradient chamber flow-injection titration (GCFIT) method with spectrophotometric detection to determine acidity constants is presented. The procedure involves the use of an acid-base indicator to obtain…

  6. A titration model for evaluating calcium hydroxide removal techniques.

    PubMed

    Phillips, Mark; McClanahan, Scott; Bowles, Walter

    2015-01-01

    Calcium hydroxide (Ca(OH)2) has been used in endodontics as an intracanal medicament due to its antimicrobial effects and its ability to inactivate bacterial endotoxin. The inability to totally remove this intracanal medicament from the root canal system, however, may interfere with the setting of eugenol-based sealers or inhibit bonding of resin to dentin, thus presenting clinical challenges with endodontic treatment. This study used a chemical titration method to measure residual Ca(OH)2 left after different endodontic irrigation methods. Eighty-six human canine roots were prepared for obturation. Thirty teeth were filled with known but different amounts of Ca(OH)2 for 7 days, which were dissolved out and titrated to quantitate the residual Ca(OH)2 recovered from each root to produce a standard curve. Forty-eight of the remaining teeth were filled with equal amounts of Ca(OH)2 followed by gross Ca(OH)2 removal using hand files and randomized treatment of either: 1) Syringe irrigation; 2) Syringe irrigation with use of an apical file; 3) Syringe irrigation with added 30 s of passive ultrasonic irrigation (PUI), or 4) Syringe irrigation with apical file and PUI (n=12/group). Residual Ca(OH)2 was dissolved with glycerin and titrated to measure residual Ca(OH)2 left in the root. No method completely removed all residual Ca(OH)2. The addition of 30 s PUI with or without apical file use removed Ca(OH)2 significantly better than irrigation alone. This technique allowed quantification of residual Ca(OH)2. The use of PUI (with or without apical file) resulted in significantly lower Ca(OH)2 residue compared to irrigation alone.

  7. Casimir force in brane worlds: Coinciding results from Green's and zeta function approaches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linares, Roman; Morales-Tecotl, Hugo A.; Pedraza, Omar

    2010-06-15

    Casimir force encodes the structure of the field modes as vacuum fluctuations and so it is sensitive to the extra dimensions of brane worlds. Now, in flat spacetimes of arbitrary dimension the two standard approaches to the Casimir force, Green's function, and zeta function yield the same result, but for brane world models this was only assumed. In this work we show that both approaches yield the same Casimir force in the case of universal extra dimensions and Randall-Sundrum scenarios with one and two branes added by p compact dimensions. Essentially, the details of the mode eigenfunctions that enter themore » Casimir force in the Green's function approach get removed due to their orthogonality relations with a measure involving the right hypervolume of the plates, and this leaves just the contribution coming from the zeta function approach. The present analysis corrects previous results showing a difference between the two approaches for the single brane Randall-Sundrum; this was due to an erroneous hypervolume of the plates introduced by the authors when using the Green's function. For all the models we discuss here, the resulting Casimir force can be neatly expressed in terms of two four-dimensional Casimir force contributions: one for the massless mode and the other for a tower of massive modes associated with the extra dimensions.« less

  8. Relations between elliptic multiple zeta values and a special derivation algebra

    NASA Astrophysics Data System (ADS)

    Broedel, Johannes; Matthes, Nils; Schlotterer, Oliver

    2016-04-01

    We investigate relations between elliptic multiple zeta values (eMZVs) and describe a method to derive the number of indecomposable elements of given weight and length. Our method is based on representing eMZVs as iterated integrals over Eisenstein series and exploiting the connection with a special derivation algebra. Its commutator relations give rise to constraints on the iterated integrals over Eisenstein series relevant for eMZVs and thereby allow to count the indecomposable representatives. Conversely, the above connection suggests apparently new relations in the derivation algebra. Under https://tools.aei.mpg.de/emzv we provide relations for eMZVs over a wide range of weights and lengths.

  9. The 1979-1980 eclipse of Zeta Aurigae. I - The circumstellar envelope

    NASA Technical Reports Server (NTRS)

    Chapman, R. D.

    1981-01-01

    A model of the K-star wind far from the K star, and its interaction with the B star, has been derived from a study of Mg(+) and C(+++) resonance lines in the spectrum of Zeta Aurigae during 1979 and 1980. A mass loss rate from the K star of 2 x 10 to the -8th solar masses/year is suggested by the data; the rate of accretion of the K supergiant's material by the B star then being such that the matter accreted over a period of ten years is of the order of the total mass of the photosphere of the B star.

  10. Determination of the titratable acidity and the pH of wine based on potentiometric flow injection analysis.

    PubMed

    Vahl, Katja; Kahlert, Heike; von Mühlen, Lisandro; Albrecht, Anja; Meyer, Gabriele; Behnert, Jürgen

    2013-07-15

    A FIA system using a pH-sensitive detector based on a graphite/quinhydrone/silicone composite electrode was applied to determine sequentially the titratable acidity and the pH of wine, as well as the sum of calcium and magnesium ions. For all measurements the same FIA configuration was used employing different carrier solutions. The results for the determination of acidity and pH are in good agreement with those obtained by classical potentiometric titrations and by pH measurements using a conventional glass electrode. The standard deviation was less than 1.5% for both kinds of measurements and the sample volume was 150 μL. The method allows about 40 determinations of titratable acidity per hour and 30 pH measurements per hour. The titration method can be adjusted to the legal requirements in USA and Europe. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Food acid content and erosive potential of sugar-free confections.

    PubMed

    Shen, P; Walker, G D; Yuan, Y; Reynolds, C; Stacey, M A; Reynolds, E C

    2017-06-01

    Dental erosion is an increasingly prevalent problem associated with frequent consumption of acidic foods and beverages. The aim of this study was to measure the food acid content and the erosive potential of a variety of sugar-free confections. Thirty sugar-free confections were selected and extracts analysed to determine pH, titratable acidity, chemical composition and apparent degree of saturation with respect to apatite. The effect of the sugar-free confections in artificial saliva on human enamel was determined in an in vitro dental erosion assay using change in surface microhardness. The change in surface microhardness was used to categorize the confections as high, moderate or low erosive potential. Seventeen of the 30 sugar-free confections were found to contain high concentrations of food acids, exhibit low pH and high titratable acidity and have high erosive potential. Significant correlations were found between the dental erosive potential (change in enamel surface microhardness) and pH and titratable acidity of the confections. Ten of these high erosive potential confections displayed dental messages on the packaging suggesting they were safe for teeth. Many sugar-free confections, even some with 'Toothfriendly' messages on the product label, contain high contents of food acids and have erosive potential. © 2017 Australian Dental Association.

  12. The efficacy of three different mask styles on a PAP titration night.

    PubMed

    Ebben, Matthew R; Oyegbile, Temitayo; Pollak, Charles P

    2012-06-01

    This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Nurse-coordinated care improves the achievement of LDL cholesterol targets through more intensive medication titration.

    PubMed

    Snaterse, Marjolein; Jorstad, Harald T; Heiligenberg, Marlies; Ter Riet, Gerben; Boekholdt, S Matthijs; Scholte Op Reimer, Wilma; Peters, Ron J

    2017-01-01

    Nurse-coordinated care (NCC) improves the achievement of low-density lipoprotein-cholesterol (LDL-C) targets after an acute coronary syndrome (ACS). We hypothesised that NCC improves achievement of LDL-C targets through more intensive medication titration. We used data from Randomised Evaluation of Secondary Prevention by Outpatient Nurse Specialists (RESPONSE), a multicentre randomised trial on the efficacy of NCC in 754 ACS patients. Follow-up data were collected at 6 and 12 months. To enable comparison between the various types and dosages of statins, we used the average lipid-lowering potency (ALLP, % LDL-C lowering) as an indicator of lipid-lowering medication intensity. Most patients in NCC intervention and usual care groups (96%) had started lipid-lowering therapy during the index hospitalisation. At 6 months, titration activities (up or down) were applied in 45% of NCC patients compared with 24% of patients receiving usual care (p<0.001), and a difference was also seen at 12 months follow-up (52% vs 34%, p<0.001). In patients not on LDL-C target at baseline, titration activities at 6 months were recorded in 63% and 30% of NCC and usual care patients respectively (p<0.001), with increased titration activities in both groups at 12 months (69% vs 43%, p<0.001). NCC is associated with more frequent and intense lipid-lowering medication titration to reach LDL-C targets as compared with usual care alone. Further, merely starting the guideline-recommended dose is insufficient to reach the guideline-recommended LDL-C target level. TC1290 (Netherlands).

  14. Use of vitreous carbon as a working electrode in coulometric titration of potassium hydrogen phthalate.

    PubMed

    Jennings, V J; Dodson, A; Tedds, G

    1973-07-01

    The use of a vitreous carbon electrode as a cathode in the amperostatic coulometric titration of aqueous potassium hydrogen phthalate solution is described. It is shown that 10 mg of the phthalate can be titrated with a precision better than 0.5%. Current-voltage curves for platinum and vitreous carbon cathodes show that there is an overpotential on the latter relative to the former.

  15. Constant-pH molecular dynamics using stochastic titration

    NASA Astrophysics Data System (ADS)

    Baptista, António M.; Teixeira, Vitor H.; Soares, Cláudio M.

    2002-09-01

    A new method is proposed for performing constant-pH molecular dynamics (MD) simulations, that is, MD simulations where pH is one of the external thermodynamic parameters, like the temperature or the pressure. The protonation state of each titrable site in the solute is allowed to change during a molecular mechanics (MM) MD simulation, the new states being obtained from a combination of continuum electrostatics (CE) calculations and Monte Carlo (MC) simulation of protonation equilibrium. The coupling between the MM/MD and CE/MC algorithms is done in a way that ensures a proper Markov chain, sampling from the intended semigrand canonical distribution. This stochastic titration method is applied to succinic acid, aimed at illustrating the method and examining the choice of its adjustable parameters. The complete titration of succinic acid, using constant-pH MD simulations at different pH values, gives a clear picture of the coupling between the trans/gauche isomerization and the protonation process, making it possible to reconcile some apparently contradictory results of previous studies. The present constant-pH MD method is shown to require a moderate increase of computational cost when compared to the usual MD method.

  16. Equivalence of Nasal and Oronasal Masks during Initial CPAP Titration for Obstructive Sleep Apnea Syndrome

    PubMed Central

    Teo, Ming; Amis, Terence; Lee, Sharon; Falland, Karina; Lambert, Stephen; Wheatley, John

    2011-01-01

    Study Objective: Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Design: Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Setting: Accredited laboratory in a university hospital. Patients or Participants: Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. Interventions: CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. Measurements and Results: There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H2O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Conclusions: Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Clinical Trial Registration: Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx Citation: Teo M

  17. Effect of neuromonitor-guided titrated care on brain tissue hypoxia after opioid overdose cardiac arrest.

    PubMed

    Elmer, Jonathan; Flickinger, Katharyn L; Anderson, Maighdlin W; Koller, Allison C; Sundermann, Matthew L; Dezfulian, Cameron; Okonkwo, David O; Shutter, Lori A; Salcido, David D; Callaway, Clifton W; Menegazzi, James J

    2018-04-18

    Brain tissue hypoxia may contribute to preventable secondary brain injury after cardiac arrest. We developed a porcine model of opioid overdose cardiac arrest and post-arrest care including invasive, multimodal neurological monitoring of regional brain physiology. We hypothesized brain tissue hypoxia is common with usual post-arrest care and can be prevented by modifying mean arterial pressure (MAP) and arterial oxygen concentration (PaO 2 ). We induced opioid overdose and cardiac arrest in sixteen swine, attempted resuscitation after 9 min of apnea, and randomized resuscitated animals to three alternating 6-h blocks of standard or titrated care. We invasively monitored physiological parameters including brain tissue oxygen (PbtO 2 ). During standard care blocks, we maintained MAP > 65 mmHg and oxygen saturation 94-98%. During titrated care, we targeted PbtO2 > 20 mmHg. Overall, 10 animals (63%) achieved ROSC after a median of 12.4 min (range 10.8-21.5 min). PbtO 2 was higher during titrated care than standard care blocks (unadjusted β = 0.60, 95% confidence interval (CI) 0.42-0.78, P < 0.001). In an adjusted model controlling for MAP, vasopressors, sedation, and block sequence, PbtO 2 remained higher during titrated care (adjusted β = 0.75, 95%CI 0.43-1.06, P < 0.001). At three predetermined thresholds, brain tissue hypoxia was significantly less common during titrated care blocks (44 vs 2% of the block duration spent below 20 mmHg, P < 0.001; 21 vs 0% below 15 mmHg, P < 0.001; and, 7 vs 0% below 10 mmHg, P = .01). In this model of opioid overdose cardiac arrest, brain tissue hypoxia is common and treatable. Further work will elucidate best strategies and impact of titrated care on functional outcomes. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Influence of kinetics on the determination of the surface reactivity of oxide suspensions by acid-base titration.

    PubMed

    Duc, M; Adekola, F; Lefèvre, G; Fédoroff, M

    2006-11-01

    The effect of acid-base titration protocol and speed on pH measurement and surface charge calculation was studied on suspensions of gamma-alumina, hematite, goethite, and silica, whose size and porosity have been well characterized. The titration protocol has an important effect on surface charge calculation as well as on acid-base constants obtained by fitting of the titration curves. Variations of pH versus time after addition of acid or base to the suspension were interpreted as diffusion processes. Resulting apparent diffusion coefficients depend on the nature of the oxide and on its porosity.

  19. Comparison of a gel microcolumn assay with the conventional tube test for red blood cell alloantibody titration.

    PubMed

    Finck, Rachel; Lui-Deguzman, Carrie; Teng, Shih-Mao; Davis, Rebecca; Yuan, Shan

    2013-04-01

    Titration is a semiquantitative method used to estimate red blood cell (RBC) alloantibody reactivity. The conventional tube test (CTT) technique is the traditional method for performing titration studies. The gel microcolumn assay (GMA) is also a sensitive method to detect RBC alloantibodies. The aim of this study was to compare a GMA with the CTT technique in the performance of Rh and K alloantibody titration. Patient serum samples that contained an RBC alloantibody with a singular specificity were identified by routine blood bank workflow. Parallel titration studies were performed on these samples by both the CTT method and a GMA (ID-Micro Typing System anti-IgG gel card, Micro Typing Systems, Inc., an Ortho-Clinical Diagnostics Company). Forty-eight samples were included, including 11 anti-D, five anti-c, 13 anti-E, one anti-C, three anti-e, and 15 anti-K. Overall, the two methods generated identical results in 21 of 48 samples. For 42 samples (87.5%) the two methods generated results that were within one serial dilution, and for the remaining six samples, results were within two dilutions. GMA systems may perform comparably to the CTT in titrating alloantibodies to Rh and Kell antigens. © 2012 American Association of Blood Banks.

  20. Poly(propyleneimine) glycodendrimers non-covalently bind ATP in a pH- and salt-dependent manner - model studies for adenosine analogue drug delivery.

    PubMed

    Gorzkiewicz, Michał; Buczkowski, Adam; Appelhans, Dietmar; Voit, Brigitte; Pułaski, Łukasz; Pałecz, Bartłomiej; Klajnert-Maculewicz, Barbara

    2018-06-10

    Adenosine analogue drugs (such as fludarabine or cladribine) require transporter-mediated uptake into cells and subsequent phosphorylation for anticancer activity. Therefore, application of nanocarrier systems for direct delivery of active triphosphate forms has been proposed. Here, we applied isothermal titration calorimetry and zeta potential titration to determine the stoichiometry and thermodynamic parameters of interactions between 4th generation poly(propyleneimine) dendrimers (unmodified or sugar-modified for increased biocompatibility) and ATP as a model adenosine nucleotide. We showed that glycodendrimers have the ability to efficiently interact with nucleoside triphosphates and to form stable complexes via electrostatic interactions between the ionized phosphate and amino groups on the nucleotide and the dendrimer, respectively. The complexation process is spontaneous, enthalpy-driven and depends on buffer composition (strongest interactions in organic buffer) and pH (more binding sites in acidic pH). These properties allow us to consider maltose-modified dendrimers as especially promising carriers for adenosine analogues. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Rocket spectroscopy of zeta Orionis.

    NASA Technical Reports Server (NTRS)

    Smith, A. M.

    1972-01-01

    Analysis of a spectrum of zeta Ori extending from 922 to 1453 A with approximately 0.8 A resolution recorded at rocket altitudes. All lines used in existing models of stellar atmospheres appear in the recorded spectrum with the exception of those masked by telluric N2 or strong P Cygni-type profiles and by an O V line at 1371.29 A. Fifteen multiplets of subordinate lines have been reliably identified, indicating an approximate range of excitation from 0 to 50 eV. Transitions in C III (1176 A), N III (991 A), N V (1239, 1243 A), O VI (1032, 1038 A), Si IV (1394, 1403 A), S IV (1063, 1074 A), and S VI (933, 944 A) have been observed as P Cygni-type profiles presumably arising in a circumstellar envelope. The degree of ionization, transitions present, and mean radial velocities are all consistent with viewing the envelope as a hot (about 100,000 K), rarefied plasma in which collisional ionization is important. Interstellar lines in C I (1277, 1280 A), C II (1036, 1334 A), N I (1134-1135 A), N I (1200-1201 A), N II (1084-1086 A), O I (1302, 1305 A), Si II (1190, 1193 A), Si II (1260 A), and Si II (1304 A) have been definitely identified. Other transitions in Ar II, S I, C I, and Fe II are tentatively identified. The equivalent width of the L alpha line is found to be 10.4 plus or minus 1.6 A, corresponding to a columnar density of 2.0 plus or minus 0.7 x 10 to the 20th per cu cm.

  2. Developing and Demonstrating an Augmented Reality Colorimetric Titration Tool

    ERIC Educational Resources Information Center

    Tee, Nicholas Yee Kwang; Gan, Hong Seng; Li, Jonathan; Cheong, Brandon Huey-Ping; Tan, Han Yen; Liew, Oi Wah; Ng, Tuck Wah

    2018-01-01

    The handling of chemicals in the laboratory presents a challenge in instructing large class sizes and when students are relatively new to the laboratory environment. In this work, we describe and demonstrate an augmented reality colorimetric titration tool that operates out of the smartphone or tablet of students. It allows multiple students to…

  3. Detection of GRB 060927 at zeta = 5.47: Implications for the Use of Gamma-Ray Bursts as Probes of the End of the Dark Ages

    NASA Technical Reports Server (NTRS)

    Ruiz-Velasco, A. E.; Swan, H.; Troja, E.; Malesani, D.; Fynbo, J. P. U.; Sterling, R. L. C.; Xu, D.; Aharonian, F.; Akerlof, C.; Andersen, M. I.; hide

    2007-01-01

    We report on follow-up observations of the gamma-ray burst GRB 060927 using the robotic ROTSE-IIIa telescope and a suite of larger aperture groundbased telescopes. An optical afterglow was detected 20 s after the burst, the earliest rest-frame detection of optical emission from any GRB. Spectroscopy performed with the VLT about 13 hours after the trigger shows a continuum break at lambda approx. equals 8070 A, produced by neutral hydrogen absorption at zeta = 5.6. We also detect an absorption line at 8158 A which we interpret as Si II lambda 1260 at zeta = 5.467. Hence, GRB 060927 is the second most distant GRB with a spectroscopically measured redshift. The shape of the red wing of the spectral break can be fitted by a damped Ly(alpha) profile with a column density with log(N(sub HI)/sq cm) = 22.50 +/- 0.15. We discuss the implications of this work for the use of GRBs as probes of the end of the dark ages and draw three main conclusions: i) GRB afterglows originating from zeta greater than or approx. equal to 6 should be relatively easy to detect from the ground, but rapid near-infrared monitoring is necessary to ensure that they are found; ii) The presence of large H I column densities in some GRBs host galaxies at zeta > 5 makes the use of GRBs to probe the reionization epoch via spectroscopy of the red damping wing challenging; iii) GRBs appear crucial to locate typical star-forming galaxies at zeta > 5 and therefore the type of galaxies responsible for the reionization of the universe.

  4. Control of OSA During Automatic Positive Airway Pressure Titration in a Clinical Case Series: Predictors and Accuracy of Device Download Data

    PubMed Central

    Huang, Hsin-Chia Carol; Hillman, David R.; McArdle, Nigel

    2012-01-01

    Study Objectives: To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Design: Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Setting: Tertiary sleep clinic. Participants: There were 190 consecutive patients with OSA referred for APAP titration. Measurements and Results: There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI < 10, or at least 50% reduction in AHI if diagnostic AHI < 15/hr) during APAP titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square < 0.001). Conclusion: In a clinical sample control of OSA during APAP titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices. Citation: Huang HCC; Hillman DR; McArdle N. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data. SLEEP 2012;35(9):1277

  5. Expression of the growth factor pleiotrophin and its receptor protein tyrosine phosphatase beta/zeta in the serum, cartilage and subchondral bone of patients with osteoarthritis.

    PubMed

    Kaspiris, Angelos; Mikelis, Constantinos; Heroult, Melanie; Khaldi, Lubna; Grivas, Theodoros B; Kouvaras, Ioannis; Dangas, Spyridon; Vasiliadis, Elias; Lioté, Frédéric; Courty, José; Papadimitriou, Evangelia

    2013-07-01

    Pleiotrophin is a heparin-binding growth factor expressed in embryonic but not mature cartilage, suggesting a role in cartilage development. Elucidation of the molecular changes observed during the remodelling process in osteoarthritis is of paramount importance. This study aimed to investigate serum pleiotrophin levels and expression of pleiotrophin and its receptor protein tyrosine phosphatase beta/zeta in the cartilage and subchondral bone of osteoarthritis patients. Serum samples derived from 16 osteoarthritis patients and 18 healthy donors. Pleiotrophin and receptor protein tyrosine phosphatase beta/zeta in the cartilage and subchondral bone were studied in 29 patients who had undergone total knee or hip replacement for primary osteoarthritis and in 10 control patients without macroscopic osteoarthritis changes. Serum pleiotrophin levels and expression of pleiotrophin in chondrocytes and subchondral bone osteocytes significantly increased in osteoarthritis patients graded Ahlback II to III. Receptor protein tyrosine phosphatase beta/zeta was mainly detected in the subchondral bone osteocytes of patients with moderate osteoarthritis and as disease severity increased, in the osteocytes and bone lining cells of the distant trabeculae. These data render pleiotrophin and receptor protein tyrosine phosphatase beta/zeta promising candidates for further studies towards developing targeted therapeutic schemes for osteoarthritis. Copyright © 2012 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  6. Titration of Serum Lipoproteins with Lipoprotein Precipitants.

    DTIC Science & Technology

    1981-12-01

    Lipid Res 11:583 (1970). 6. Grove, T. H. Effect of reagent pH on determination of high-density lipo- protein cholesterol by precipitation with sodium ...of choles- terol in the supernate plateaued at 43 mg/dl after the beta and prebeta lipo- proteins had been precipitated . The intensities of the two...AD-A113 370 SCHOOL OF AEROSPACE MEDICINE BROOKS AFS TX F/S 6/1 TITRATION OF SERU’LIPOPROTEINS WITH LIPOPROTEIN PRECIPITANTS .(Ul DEC 81 0 A CLARK. J A

  7. Expert Comment: Is Medication Titration in Heart Failure too Complex?

    PubMed Central

    Hickey, Annabel

    2017-01-01

    Abstract Large-scale randomised controlled trials (RCTs) have demonstrated that angiotensin-converting enzyme inhibitors, angiotensin receptor blockers and beta-blockers decrease mortality and hospitalisation in patients with heart failure (HF) associated with a reduced left ventricular ejection fraction. This has led to high prescription rates; however, these drugs are generally prescribed at much lower doses than the doses achieved in the RCTs. A number of strategies have been evaluated to improve medication titration in HF, including forced medication up-titration protocols, point-of-care decision support and extended scope of clinical practice for nurses and pharmacists. Most successful strategies have been multifaceted and have adapted existing multidisciplinary models of care. Furthermore, given the central role of general practitioners in long-term monitoring and care coordination in HF patients, these strategies should engage with primary care to facilitate the transition between the acute and primary healthcare sectors. PMID:28785472

  8. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data.

    PubMed

    Huang, Hsin-Chia Carol; Hillman, David R; McArdle, Nigel

    2012-09-01

    To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Tertiary sleep clinic. There were 190 consecutive patients with OSA referred for APAP titration. There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI < 10, or at least 50% reduction in AHI if diagnostic AHI < 15/hr) during APAP titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square < 0.001). In a clinical sample control of OSA during APAP titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices.

  9. Barriers to and enablers of insulin self-titration in adults with Type 2 diabetes: a qualitative study.

    PubMed

    McBain, H; Begum, S; Rahman, S; Mulligan, K

    2017-02-01

    To identify the barriers to and enablers of effective insulin self-titration in people with Type 2 diabetes. A qualitative semi-structured interview approach was used. Questions were structured according to the Theoretical Domains Framework, which outlines 14 domains that can act as barriers to and enablers of changing behaviour. Interviews were audio-recorded and transcribed verbatim. The data were coded according to the 14 domains, belief statements were created within each domain, and a frequency count of the most reported barriers and enablers was then carried out. Analyses were conducted by two researchers, and discrepancies agreed with a third researcher. A total of 18 adults with Type 2 diabetes took part in an interview. The majority were of South-Asian ethnicity (n = 8) and were men (n = 12). Their mean age was 61 years old. The mean duration of diabetes was 16 years and time on insulin 9 years. Inter-rater reliability for each of the domains varied (29-100%). The most frequently reported domains were Social Influence and Beliefs about Consequences; the least frequently reported were Optimism and Reinforcement. Interviewees reported receiving support to self-titrate from a range of sources. Self-titrating was perceived to have a range of both positive and negative consequences, as was not titrating. The findings highlight that those interviewed experienced a range of barriers and enablers when attempting to self-titrate. Improved education and training when initiating insulin treatment among adults with Type 2 diabetes, and throughout their journey on insulin therapy could help identify and address these barriers in order to optimize self-titration. © 2016 Diabetes UK.

  10. Barriers to Beta-Blocker Use and Up-Titration Among Patients with Heart Failure with Reduced Ejection Fraction.

    PubMed

    Levitan, Emily B; Van Dyke, Melissa K; Loop, Matthew Shane; O'Beirne, Ronan; Safford, Monika M

    2017-12-01

    For patients with heart failure with reduced ejection fraction (HFrEF), guidelines recommend use of beta-blockers with gradual up-titration. However, many patients with HFrEF do not use beta-blockers and up-titration is rare. Our purpose was to identify and rank barriers to beta-blocker use and up-titration from the perspective of primary care physicians. We conducted 4 moderated, structured group discussions among 19 primary care physicians using the nominal group technique; 16 participants also completed a survey. Participants generated lists of barriers to beta-blocker use and up-titration among patients with HFrEF. Each participant had six votes with three votes assigned to the item ranked most important, two to the second most important item, and one to the third most important item. Investigators characterized items into themes. The percentage of available votes was calculated for each theme. Fifteen of 16 participating primary care physicians who completed the survey reported that management of beta-blockers was their responsibility. Treatment/side effects, particularly hypotension, were identified as the most important barrier for beta-blocker use (72% of available votes) followed by polypharmacy (11%), healthcare system barriers (10%), and comorbidities (6%). Barriers to up-titration included treatment/side effects (49% of available votes), patient communication/buy-in (21%), polypharmacy (13%), and healthcare system barriers (8%). Many barriers to guideline concordant use of beta-blockers among patients with HFrEF identified by primary care providers are not readily modifiable. Addressing these barriers may require development, testing, and dissemination of protocols for beta-blocker initiation and up-titration that are safe and appropriate in primary care.

  11. Relationship between phospholipase C-zeta, semen parameters, and chromatin status.

    PubMed

    Tavalaee, Marziyeh; Kiani-Esfahani, Abbas; Nasr-Esfahani, Mohammad H

    2017-08-01

    The need for additional tests to complement basic sperm analysis in clinics is well appreciated. In this regard, a number of tests such as sperm DNA integrity test as a tool in diagnosis and treatment of infertility are suggested. But recent studies have focused on main sperm factors involved in oocyte activation such as phospholipase C-zeta (PLCζ) that initiate intracellular Ca 2+ signaling and embryogenesis. Therefore, this study aimed to investigate the relationship between PLCζ, basic semen parameters, sperm DNA fragmentation (SDF), and protamine deficiency in men with normal (n=32) and abnormal (n=23) semen parameters. Unlike SDF and protamine deficiency, as negative factors related to fertility, the mean value of PLCζ as positive factor related to infertility was significantly lower in men with abnormal semen parameters compared to men with normal semen parameters. Significant correlations were also observed between sperm concentration, motility, and abnormal morphology with the percentage of PLCζ positive spermatozoa. In addition, logistic regression analysis revealed that sperm morphology is more predictive than sperm motility and concentration for PLCζ presence. In addition, a statistically significant negative relationship was observed between the percentage of PLCζ positive spermatozoa and SDF. These findings suggested during ICSI, selection of sperm based on morphology has a profound effect on its ability to induce oocyte activation based on the likelihood of PLCζ expression. Therefore, assessment of PLCζ as an index for fertilization potential of a semen sample in men with severe teratozoospermia may define individuals who are candidates for artificial oocyte activation (AOA) and may avoid failed fertilization post ICSI.

  12. Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome.

    PubMed

    Teo, Ming; Amis, Terence; Lee, Sharon; Falland, Karina; Lambert, Stephen; Wheatley, John

    2011-07-01

    Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Accredited laboratory in a university hospital. Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H(2)O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx

  13. The influence of graded degrees of chronic hypercapnia on the acute carbon dioxide titration curve

    PubMed Central

    Goldstein, Marc B.; Gennari, F. John; Schwartz, William B.

    1971-01-01

    Studies were carried out to determine the influence of the chronic level of arterial carbon dioxide tension upon the buffering response to acute changes in arterial carbon dioxide tension. After chronic adaptation to six levels of arterial CO2 tension, ranging between 35 and 110 mm Hg, unanesthetized dogs underwent acute whole body CO2 titrations. In each instance a linear relationship was observed between the plasma hydrogen ion concentration and the arterial carbon dioxide tension. Because of this linear relationship, it has been convenient to compare the acute buffering responses among dogs in terms of the slope, dH+/dPaco2. With increasing chronic hypercapnia there was a decrease in this slope, i.e. an improvement in buffer capacity, which is expressed by the equation dH+/dPaco2=-0.005 (Paco2)chronic + 0.95. In effect, the ability to defend pH during acute titration virtually doubled as chronic Paco2 increased from 35 to 110 mm Hg. The change in slope, dH+/dPaco2, was the consequence of the following two factors: the rise in plasma bicarbonate concentration which occurs with chronic hypercapnia of increasing severity, and the greater change in bicarbonate concentration which occurred during the acute CO2 titration in the animals with more severe chronic hypercapnia. These findings demonstrate the importance of the acid-base status before acute titration in determining the character of the carbon dioxide titration curve. They also suggest that a quantitative definition of the interplay between acute and chronic hypercapnia in man should assist in the rational analysis of acid-base disorders in chronic pulmonary insufficiency. PMID:5543876

  14. Nurse-coordinated care improves the achievement of LDL cholesterol targets through more intensive medication titration

    PubMed Central

    Snaterse, Marjolein; Jorstad, Harald T; Heiligenberg, Marlies; ter Riet, Gerben; Boekholdt, S Matthijs; Scholte op Reimer, Wilma; Peters, Ron J

    2017-01-01

    Background Nurse-coordinated care (NCC) improves the achievement of low-density lipoprotein-cholesterol (LDL-C) targets after an acute coronary syndrome (ACS). We hypothesised that NCC improves achievement of LDL-C targets through more intensive medication titration. Methods We used data from Randomised Evaluation of Secondary Prevention by Outpatient Nurse Specialists (RESPONSE), a multicentre randomised trial on the efficacy of NCC in 754 ACS patients. Follow-up data were collected at 6 and 12 months. To enable comparison between the various types and dosages of statins, we used the average lipid-lowering potency (ALLP, % LDL-C lowering) as an indicator of lipid-lowering medication intensity. Results Most patients in NCC intervention and usual care groups (96%) had started lipid-lowering therapy during the index hospitalisation. At 6 months, titration activities (up or down) were applied in 45% of NCC patients compared with 24% of patients receiving usual care (p<0.001), and a difference was also seen at 12 months follow-up (52% vs 34%, p<0.001). In patients not on LDL-C target at baseline, titration activities at 6 months were recorded in 63% and 30% of NCC and usual care patients respectively (p<0.001), with increased titration activities in both groups at 12 months (69% vs 43%, p<0.001). Conclusion NCC is associated with more frequent and intense lipid-lowering medication titration to reach LDL-C targets as compared with usual care alone. Further, merely starting the guideline-recommended dose is insufficient to reach the guideline-recommended LDL-C target level. Trial Registration number TC1290 (Netherlands). PMID:28761680

  15. Volumetric determination of uranium titanous sulfate as reductant before oxidimetric titration

    USGS Publications Warehouse

    Wahlberg, J.S.; Skinner, D.L.; Rader, L.F.

    1957-01-01

    Need for a more rapid volumetric method for the routine determination of uranium in uranium-rich materials has led to the development of a method that uses titanous sulfate as a reductant before oxidimetric titration. Separation of the hydrogen sulfide group is not necessary. Interfering elements precipitated by cupferron are removed by automatic filtrations made simultaneously rather than by the longer chloroform extraction method. Uranium is reduced from VI to IV by addition of an excess of titanous sulfate solution, cupric ion serving as an indicator by forming red metallic copper when reduction is complete. The copper is reoxidized by addition of mercuric perchlorate. The reduced uranium is then determined by addition of excess ferric sulfate and titration with ceric sulfate. The method has proved to be rapid, accurate, and economical.

  16. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    PubMed

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  17. Titration of Alanine Monitored by NMR Spectroscopy: A Biochemistry Laboratory Experiment

    ERIC Educational Resources Information Center

    Waller, Francis J.; And Others

    1977-01-01

    The experiment described here involves simultaneous monitoring of pH and NMR chemical shifts during an aqueous titration of alpha- and beta-alanine. This experiment is designed for use in an undergraduate biochemistry course. (MR)

  18. Going Beyond, Going Further: The Preparation of Acid-Base Titration Curves.

    ERIC Educational Resources Information Center

    McClendon, Michael

    1984-01-01

    Background information, list of materials needed, and procedures used are provided for a simple technique for generating mechanically plotted acid-base titration curves. The method is suitable for second-year high school chemistry students. (JN)

  19. Hippocampal Infusion of Zeta Inhibitory Peptide Impairs Recent, but Not Remote, Recognition Memory in Rats

    PubMed Central

    Hales, Jena B.; Ocampo, Amber C.; Broadbent, Nicola J.; Clark, Robert E.

    2015-01-01

    Spatial memory in rodents can be erased following the infusion of zeta inhibitory peptide (ZIP) into the dorsal hippocampus via indwelling guide cannulas. It is believed that ZIP impairs spatial memory by reversing established late-phase long-term potentiation (LTP). However, it is unclear whether other forms of hippocampus-dependent memory, such as recognition memory, are also supported by hippocampal LTP. In the current study, we tested recognition memory in rats following hippocampal ZIP infusion. In order to combat the limited targeting of infusions via cannula, we implemented a stereotaxic approach for infusing ZIP throughout the dorsal, intermediate, and ventral hippocampus. Rats infused with ZIP 3–7 days after training on the novel object recognition task exhibited impaired object recognition memory compared to control rats (those infused with aCSF). In contrast, rats infused with ZIP 1 month after training performed similar to control rats. The ability to form new memories after ZIP infusions remained intact. We suggest that enhanced recognition memory for recent events is supported by hippocampal LTP, which can be reversed by hippocampal ZIP infusion. PMID:26380123

  20. A rapid method for infectivity titration of Andes hantavirus using flow cytometry.

    PubMed

    Barriga, Gonzalo P; Martínez-Valdebenito, Constanza; Galeno, Héctor; Ferrés, Marcela; Lozach, Pierre-Yves; Tischler, Nicole D

    2013-11-01

    The focus assay is currently the most commonly used technique for hantavirus titer determination. This method requires an incubation time of between 5 and 11 days to allow the appearance of foci after several rounds of viral infection. The following work presents a rapid Andes virus (ANDV) titration assay, based on viral nucleocapsid protein (N) detection in infected cells by flow cytometry. To this end, an anti-N monoclonal antibody was used that was developed and characterized previously. ANDV N could be detected as early as 6 h post-infection, while viral release was not observed until 24-48 h post-infection. Given that ANDV detection was performed during its first round of infection, a time reduction for titer determination was possible and provided results in only two days. The viral titer was calculated from the percentage of N positive cells and agreed with focus assay titers. Furthermore, the assay was applied to quantify the inhibition of ANDV cell entry by patient sera and by preventing endosome acidification. This novel hantavirus titration assay is a highly quantitative and sensitive tool that facilitates infectivity titration of virus stocks, rapid screening for antiviral drugs, and may be further used to detect and quantify infectious virus in human samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. [Computer modeling the dependences of the membrane potential for polymeric membrane separated non-homogeneous electrolyte solutions on concentration Rayleigh number].

    PubMed

    Slezak, Izabella H; Jasik-Slezak, Jolanta; Bilewicz-Wyrozumska, Teresa; Slezak, Andrzej

    2006-01-01

    On the basis of model equation describing the membrane potential delta psi(s) on concentration Rayleigh number (R(C)), mechanical pressure difference (deltaP), concentration polarization coefficient (zeta s) and ratio concentration of solutions separated by membrane (Ch/Cl), the characteristics delta psi(s) = f(Rc)(delta P, zeta s, Ch/Cl) for steady values of zeta s, R(C) and Ch/Cl in single-membrane system were calculated. In this system neutral and isotropic polymeric membrane oriented in horizontal plane, the non-homogeneous binary electrolytic solutions of various concentrations were separated. Nonhomogeneity of solutions is results from creations of the concentration boundary layers on both sides of the membrane. Calculations were made for the case where on a one side of the membrane aqueous solution of NaCl at steady concentration 10(-3) mol x l(-1) (Cl) was placed and on the other aqueous solutions of NaCl at concentrations from 10(-3) mol x l(-1) to 2 x 10(-2) mol x l(-1) (Ch). Their densities were greater than NaCl solution's at 10(-3) mol x l(-1). It was shown that membrane potential depends on hydrodynamic state of a complex concentration boundary layer-membrane-concentration boundary layer, what is controlled by deltaP, Ch/Cl, Rc and Zeta(s).

  2. Titration effectiveness of two autoadjustable continuous positive airway pressure devices driven by different algorithms in patients with obstructive sleep apnoea.

    PubMed

    Damiani, Mario Francesco; Quaranta, Vitaliano Nicola; Tedeschi, Ersilia; Drigo, Riccardo; Ranieri, Teresa; Carratù, Pierluigi; Resta, Onofrio

    2013-08-01

    Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  3. Subject-driven titration of biphasic insulin aspart 30 twice daily is non-inferior to investigator-driven titration in Chinese patients with type 2 diabetes inadequately controlled with premixed human insulin: A randomized, open-label, parallel-group, multicenter trial.

    PubMed

    Yang, Wenying; Zhu, Lvyun; Meng, Bangzhu; Liu, Yu; Wang, Wenhui; Ye, Shandong; Sun, Li; Miao, Heng; Guo, Lian; Wang, Zhanjian; Lv, Xiaofeng; Li, Quanmin; Ji, Qiuhe; Zhao, Weigang; Yang, Gangyi

    2016-01-01

    The present study was to compare the efficacy and safety of subject-driven and investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) twice daily (BID). In this 20-week, randomized, open-label, two-group parallel, multicenter trial, Chinese patients with type 2 diabetes inadequately controlled by premixed/self-mixed human insulin were randomized 1:1 to subject-driven or investigator-driven titration of BIAsp 30 BID, in combination with metformin and/or α-glucosidase inhibitors. Dose adjustment was decided by patients in the subject-driven group after training, and by investigators in the investigator-driven group. Eligible adults (n = 344) were randomized in the study. The estimated glycated hemoglobin (HbA1c) reduction was 14.5 mmol/mol (1.33%) in the subject-driven group and 14.3 mmol/mol (1.31%) in the investigator-driven group. Non-inferiority of subject-titration vs investigator-titration in reducing HbA1c was confirmed, with estimated treatment difference -0.26 mmol/mol (95% confidence interval -2.05, 1.53) (-0.02%, 95% confidence interval -0.19, 0.14). Fasting plasma glucose, postprandial glucose increment and self-measured plasma glucose were improved in both groups without statistically significant differences. One severe hypoglycemic event was experienced by one subject in each group. A similar rate of nocturnal hypoglycemia (events/patient-year) was reported in the subject-driven (1.10) and investigator-driven (1.32) groups. There were 64.5 and 58.1% patients achieving HbA1c <53.0 mmol/mol (7.0%), and 51.2 and 45.9% patients achieving the HbA1c target without confirmed hypoglycemia throughout the trial in the subject-driven and investigator-driven groups, respectively. Subject-titration of BIAsp 30 BID was as efficacious and well-tolerated as investigator-titration. The present study supported patients to self-titrate BIAsp 30 BID under physicians' supervision.

  4. Evanescent-wave particle velocimetry measurements of zeta-potentials in fused-silica microchannels.

    PubMed

    Cevheri, Necmettin; Yoda, Minami

    2013-07-01

    The wall ζ-potential ζ(w), the potential at the shear plane of the electric double layer, depends on the properties of the BGE solution such as the valence and type of electrolyte, the pH and the ionic strength. Most of the methods estimate ζ(w) from measurements of the EOF velocity magnitude ueo , usually spatially averaged over the entire capillary. In these initial studies, evanescent-wave particle velocimetry was used to measure ueo in steady EOF for a variety of monovalent aqueous solutions to evaluate the effect of small amounts of divalent cations, as well as the pH and ionic strength of BGE solutions. In brief, the magnitude of the EOF velocity of NaCl-NaOH and borate buffer-NaOH solutions was estimated from the measured velocities of radius α = 104 nm fluorescent polystyrene particles in 33 μm fused-silica microchannels. The particle ζ-potentials were measured separately using laser-Doppler micro-electrophoresis; ζ(w) was then determined from ueo. The results suggest that evanescent-wave particle velocimetry can be used to estimate ζ(w) for a variety of BGE solutions, and that it can be used in the future to estimate local wall ζ-potential, and hence spatial variations in ζ(w). © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Potentiometric titration of polyhexamethylene biguanide hydrochloride with potassium poly(vinyl sulfate) solution using a cationic surfactant-selective electrode.

    PubMed

    Masadome, Takashi; Yamagishi, Yuichi; Takano, Masaki; Hattori, Toshiaki

    2008-03-01

    A potentiometric titration method using a cationic surfactant as an indicator cation and a plasticized poly(vinyl chloride) membrane electrode sensitive to the cationic surfactant is proposed for the determination of polyhexamethylene biguanide hydrochloride (PHMB-HCl), which is a cationic polyelectrolyte. A sample solution of PHMB-HCl containing an indicator cation (hexadecyltrimethylammonium ion, HTA) was titrated with a standard solution of an anionic polyelectrolyte, potassium poly(vinyl sulfate) (PVSK). The end-point was detected as a sharp potential change due to an abrupt decrease in the concentration of the indicator cation, HTA, which is caused by its association with PVSK. The effects of the concentrations of HTA ion and coexisting electrolytes in the sample solution on the degree of the potential change at the end-point were examined. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant exists in the concentration range from 2.0 x 10(-5) to 4.0 x 10(-4) M in the case that the concentration of HTA is 1.0 x 10(-5) M, and that from 1.0 x 10(-6) to 1.2 x 10(-5) M in the case that the concentration of HTA is 5.0 x 10(-6) M, respectively. The proposed method was applied to the determination of PHMB-HCl in some contact-lens detergents.

  6. Fast Proton Titration Scheme for Multiscale Modeling of Protein Solutions.

    PubMed

    Teixeira, Andre Azevedo Reis; Lund, Mikael; da Silva, Fernando Luís Barroso

    2010-10-12

    Proton exchange between titratable amino acid residues and the surrounding solution gives rise to exciting electric processes in proteins. We present a proton titration scheme for studying acid-base equilibria in Metropolis Monte Carlo simulations where salt is treated at the Debye-Hückel level. The method, rooted in the Kirkwood model of impenetrable spheres, is applied on the three milk proteins α-lactalbumin, β-lactoglobulin, and lactoferrin, for which we investigate the net-charge, molecular dipole moment, and charge capacitance. Over a wide range of pH and salt conditions, excellent agreement is found with more elaborate simulations where salt is explicitly included. The implicit salt scheme is orders of magnitude faster than the explicit analog and allows for transparent interpretation of physical mechanisms. It is shown how the method can be expanded to multiscale modeling of aqueous salt solutions of many biomolecules with nonstatic charge distributions. Important examples are protein-protein aggregation, protein-polyelectrolyte complexation, and protein-membrane association.

  7. Theoretical problems associated with the use of acetic anhydride as a co-solvent for the non-aqueous titration of hydrohalides of organic bases and quaternary ammonium salts.

    PubMed

    Völgyi, Gergely; Béni, Szabolcs; Takács-Novák, Krisztina; Görög, Sándor

    2010-01-05

    A potentiometric titration study of organic base hydrohalides and quaternary ammonium salts using perchloric acid as the titrant and a mixture of acetic anhydride and acetic acid as the solvent was carried out and the titration mixture was analysed by NMR in order to clarify the chemistry of the reactions involved. It was found that in contrast to the general belief the formation of acetyl halides and titratable free acetate ion does not take place prior to the titration but NMR spectra proved the formation of acetyl halides in the course of the titration. This observation and the fact that the shape of the titration curves depends on the nature of the hydrohaloic acid bound to the base or of the anion in the quaternary ammonium salts led to the conclusion that the titrating agent is acetyl perchlorate formed in situ during the titration. Equations of the reactions involved in the titration process are shown in the paper.

  8. Acid-base titrations for polyacids: Significance of the pK sub a and parameters in the Kern equation

    NASA Technical Reports Server (NTRS)

    Meites, L.

    1978-01-01

    A new method is suggested for calculating the dissociation constants of polyvalent acids, especially polymeric acids. In qualitative form the most significant characteristics of the titration curves are demonstrated and identified which are obtained when titrating the solutions of such acids with a standard base potentiometrically.

  9. An RCT Investigating Patient-Driven Versus Physician-Driven Titration of BIAsp 30 in Patients with Type 2 Diabetes Uncontrolled Using NPH Insulin.

    PubMed

    Chraibi, Abdelmjid; Al-Herz, Shoorook; Nguyen, Bich Dao; Soeatmadji, Djoko W; Shinde, Anil; Lakshmivenkataraman, Balasubramanian; Assaad-Khalil, Samir H

    2017-08-01

    The aim of this study was to confirm the efficacy of patient-driven titration of BIAsp 30 in terms of glycemic control, by comparing it to physician-driven titration of BIAsp 30, in patients with type 2 diabetes in North Africa, the Middle East, and Asia. A 20-week, open-label, randomized, two-armed, parallel-group, multicenter study in Egypt, Indonesia, Morocco, Saudi Arabia, and Vietnam. Patients (n = 155) with type 2 diabetes inadequately controlled using neutral protamine Hagedorn (NPH) insulin were randomized to either patient-driven or physician-driven BIAsp 30 titration. The noninferiority of patient-driven compared to physician-driven titration with respect to the reduction in HbA1c was confirmed. The estimated mean change in HbA1c from baseline to week 20 was -1.27% in the patient-driven arm and -1.04% in the physician-driven arm, with an estimated treatment difference of -0.23% (95% confidence interval: -0.54; 0.08). After 20 weeks of treatment, the proportions of patients achieving the target of HbA1c <7.5% were similar between titration arms; the proportions of patients achieving the target of ≤6.5% were also similar. Both titration algorithms were well tolerated, and hypoglycemic episode rates were similar in both arms. Patient-driven titration of BIAsp 30 can be as effective and safe as physician-driven titration in non-Western populations. Overall, the switch from NPH insulin to BIAsp 30 was well tolerated in both titration arms and led to improved glycemic control. A limitation of the study was the relatively small number of patients recruited in each country. ClinicalTrials.gov NCT01589653. Novo Nordisk A/S, Denmark.

  10. Utilizing the virus-induced blocking of apoptosis in an easy baculovirus titration method

    PubMed Central

    Niarchos, Athanasios; Lagoumintzis, George; Poulas, Konstantinos

    2015-01-01

    Baculovirus-mediated protein expression is a robust experimental technique for producing recombinant higher-eukaryotic proteins because it combines high yields with considerable post-translational modification capabilities. In this expression system, the determination of the titer of recombinant baculovirus stocks is important to achieve the correct multiplicity of infection for effective amplification of the virus and high expression of the target protein. To overcome the drawbacks of existing titration methods (e.g., plaque assay, real-time PCR), we present a simple and reliable assay that uses the ability of baculoviruses to block apoptosis in their host cells to accurately titrate virus samples. Briefly, after incubation with serial dilutions of baculovirus samples, Sf9 cells were UV irradiated and, after apoptosis induction, they were viewed via microscopy; the presence of cluster(s) of infected cells as islets indicated blocked apoptosis. Subsequently, baculovirus titers were calculated through the determination of the 50% endpoint dilution. The method is simple, inexpensive, and does not require unique laboratory equipment, consumables or expertise; moreover, it is versatile enough to be adapted for the titration of every virus species that can block apoptosis in any culturable host cells which undergo apoptosis under specific conditions. PMID:26490731

  11. Concentration determination of methyl magnesium chloride and other Grignard reagents by potentiometric titration with in-line characterization of reaction species by FTIR spectroscopy.

    PubMed

    Chen, Yadan; Wang, Tao; Helmy, Roy; Zhou, George X; LoBrutto, Rosario

    2002-07-01

    A potentiometric titration method for methyl magnesium chloride and other Grignard reagents based on the reaction with 2-butanol in THF has been developed and validated. The method employs a commercially available platinum electrode, using an electrolyte compatible with non-aqueous solvents. Well-defined titration curves were obtained, along with excellent method precision. The endpoint was precisely determined based on the first derivative of the titration curve. Different solvents such as THF, diethyl ether and methylene chloride provided similar results with regard to sharpness of the endpoint and method precision. The method was applied to a wide array of Grignard reagents including methyl magnesium bromide, ethyl magnesium chloride, propyl magnesium chloride, vinyl magnesium chloride, phenyl magnesium chloride, and benzyl magnesium chloride with similar precision and accuracy. Application of in-line FTIR was demonstrated for in situ monitoring of the titration reaction, allowing characterization of the reaction species. An authentic spectrum of the MeMgCl-THF complex was obtained using spectral subtraction and the vibrational absorbance bands were identified. FTIR also provided an alternative for detecting the titration endpoint, and the titration results so obtained, provided a cross-validation of the accuracy of the potentiometric titration.

  12. Oxygen titration after resuscitation from out-of-hospital cardiac arrest: A multi-centre, randomised controlled pilot study (the EXACT pilot trial).

    PubMed

    Bray, Janet E; Hein, Cindy; Smith, Karen; Stephenson, Michael; Grantham, Hugh; Finn, Judith; Stub, Dion; Cameron, Peter; Bernard, Stephen

    2018-04-21

    Recent studies suggest the administration of 100% oxygen to hyperoxic levels following return-of-spontaneous-circulation (ROSC) post-cardiac arrest may be harmful. However, the feasibility and safety of oxygen titration in the prehospital setting is unknown. We conducted a multi-centre, phase-2 study testing whether prehospital titration of oxygen results in an equivalent number of patients arriving at hospital with oxygen saturations SpO2 ≥ 94%. We enrolled unconscious adults with: sustained ROSC; initial shockable rhythm; an advanced airway; and an SpO2 ≥ 95%. Initially (Sept 2015-March 2016) patients were randomised 1:1 to either 2 L/minute (L/min) oxygen (titrated) or >10 L/min oxygen (control) via a bag-valve reservoir. However, one site experienced a high number of desaturations (SpO2 < 94%) in the titrated arm and this arm was changed (April 2016) to an initial reduction of oxygen to 4 L/min then, if tolerated, to 2 L/min, and the desaturation limit was decreased to <90%. We randomised 61 patients to titrated (n = 37: 2L/min = 20 and 2-4 L/min = 17) oxygen or control (n = 24). Patients allocated to titrated oxygen were more likely to desaturate compared to controls ((SpO2 < 94%: 43% vs. 4%, p = 0.001; SpO2 < 90%: 19% vs. 4%, p = 0.09). The majority of desaturations (81%) occurred at 2L/min. On arrival at hospital the majority of patients had a SpO2 ≥ 94% (titrated: 90% vs. control: 100%) and all patients had a SpO2 ≥ 90%. One patient (control) re-arrested. Survival to hospital discharge was similar. Oxygen titration post-ROSC is feasible in the prehospital environment, but incremental titration commencing at 4L/min oxygen flow may be needed to maintain an oxygen saturation >90% (NCT02499042). Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Macromolecular Competition Titration Method: Accessing Thermodynamics of the Unmodified Macromolecule–Ligand Interactions Through Spectroscopic Titrations of Fluorescent Analogs

    PubMed Central

    Bujalowski, Wlodzimierz; Jezewska, Maria J.

    2011-01-01

    Analysis of thermodynamically rigorous binding isotherms provides fundamental information about the energetics of the ligand–macromolecule interactions and often an invaluable insight about the structure of the formed complexes. The Macromolecular Competition Titration (MCT) method enables one to quantitatively obtain interaction parameters of protein–nucleic acid interactions, which may not be available by other methods, particularly for the unmodified long polymer lattices and specific nucleic acid substrates, if the binding is not accompanied by adequate spectroscopic signal changes. The method can be applied using different fluorescent nucleic acids or fluorophores, although the etheno-derivatives of nucleic acid are especially suitable as they are relatively easy to prepare, have significant blue fluorescence, their excitation band lies far from the protein absorption spectrum, and the modification eliminates the possibility of base pairing with other nucleic acids. The MCT method is not limited to the specific size of the reference nucleic acid. Particularly, a simple analysis of the competition titration experiments is described in which the fluorescent, short fragment of nucleic acid, spanning the exact site-size of the protein–nucleic acid complex, and binding with only a 1:1 stoichiometry to the protein, is used as a reference macromolecule. Although the MCT method is predominantly discussed as applied to studying protein–nucleic acid interactions, it can generally be applied to any ligand–macromolecule system by monitoring the association reaction using the spectroscopic signal originating from the reference macromolecule in the presence of the competing macromolecule, whose interaction parameters with the ligand are to be determined. PMID:21195223

  14. Thickness determination of biological samples with a zeta-calibrated scanning tunneling microscope.

    PubMed Central

    Wang, Z H; Hartmann, T; Baumeister, W; Guckenberger, R

    1990-01-01

    A single-tube scanning tunneling microscope has been zeta-calibrated by using atomic steps of crystalline gold and was used for measuring the thickness of two biological samples, metal-coated as well as uncoated. The hexagonal surface layer of the bacterium Deinococcus radiodurans with an open network-type structure shows thickness values that are strongly influenced by the substrate and the preparation method. In contrast, the thickness of the purple membrane of Halobacterium halobium with its densely packed less-corrugated structure exhibits very little variation in thickness in coated preparations and the values obtained are in good agreement with x-ray data. Images PMID:2251276

  15. Three different up-titration regimens of ponesimod, an S1P1 receptor modulator, in healthy subjects.

    PubMed

    Scherz, Michael W; Brossard, Patrick; D'Ambrosio, Daniele; Ipek, Murat; Dingemanse, Jasper

    2015-06-01

    Ponesimod is a selective S1P1 receptor modulator, and induces dose-dependent reduction of circulating lymphocytes upon oral dosing. Previous studies showed that single doses up to 75 mg or multiple doses up to 40 mg once daily are well tolerated, and heart rate (HR) reduction and atrio-ventricular conduction delays upon treatment initiation are reduced by gradual up-titration to the maintenance dose. This single-center, open-label, randomized, multiple-dose, 3-treatment, 3-way crossover study compared the tolerability, safety, pharmacokinetics, cardiodynamics, and effects on lymphocytes of 3 different up-titration regimens of ponesimod in healthy male and female subjects. Up-titration regimens comprised escalating periods of b.i.d. dosing (2.5 or 5 mg) and q.d. dosing (10 or 20 mg or both). After the third up-titration period a variable-duration washout period of 1-3 days was followed by re-challenge with a single 20-mg dose of ponesimod. Adverse events were transient and mild to moderate in intensity, not different between regimens. HR decrease after the first dose was greater than after all subsequent doses, including up-titration doses. Little or no HR change was observed with morning doses of b.i.d. regimens, suggesting that 2.5 and 5 mg b.i.d. are sufficient to sustain cardiac desensitization for the 12-hours dosing interval. © 2015, The American College of Clinical Pharmacology.

  16. Measurement of atmospheric OH by titration of near-IR fluorescent dyes

    NASA Technical Reports Server (NTRS)

    Betterton, Eric A.; Gast, Karl

    1994-01-01

    Recent research has shown that certain polymethine dyes can be detected at ultratrace levels (greater than or equal to 6x10(exp -14) M) in solution by fluorimetry. These detection limits are possible because of the inherent sensitivity of fluorescence techniques, because the dyes fluoresce in the near infrared region where background interference is negligible, and because powerful infrared diode lasers are now available to improve the signal to noise ratio. Other work has shown that the hydroxyl radical destroys the ability of polymethine dyes to fluoresce. These observations form the basis for a new hydroxyl radical detector that is essentially a fluorometric titrator. Theoretically, the detector should show an acceptable sensitivity and response time. Assuming that the atmospheric HO concentration is about 10(exp -11) moles m(exp -3) (i.e. 10(exp 6) molecules cm(exp -3)), then 10 L of air 'titrated' with 20 mL of 10(exp -11) M dye solution (an easily detected concentration) should result in a drop in the fluorescent signal of 50 percent - a readily detectable change. At a flow rate of 3 L min(exp -1) the sampling time would be 3 minutes. The biggest potential problem is selectivity: other oxidants may also cause the fluorescence signal to be lost. The chemistry of polymethine dyes has not been studied in detail and so no quantitative data are available. However, a survey of the literature suggests that in general HO should react up to six orders of magnitude faster than HO2 and other radicals such as RO2 and RO. It should also react much more rapidly than H2O2 and O3. Thus it may be possible to discriminate kinetically against potential interfering substances. It was shown in the laboratory that 10(exp -4) M H2O2 has little effect on the absorption spectrum of the dye IR125 over a period of hours but that the band at 780 nm is slowly lost in water over a period of days even under argon in the dark. By contrast, DMSO solutions of IR125 are stable.

  17. Statistical mechanical model of coupled transcription from multiple promoters due to transcription factor titration

    PubMed Central

    Rydenfelt, Mattias; Cox, Robert Sidney; Garcia, Hernan; Phillips, Rob

    2014-01-01

    Transcription factors (TFs) with regulatory action at multiple promoter targets is the rule rather than the exception, with examples ranging from the cAMP receptor protein (CRP) in E. coli that regulates hundreds of different genes simultaneously to situations involving multiple copies of the same gene, such as plasmids, retrotransposons, or highly replicated viral DNA. When the number of TFs heavily exceeds the number of binding sites, TF binding to each promoter can be regarded as independent. However, when the number of TF molecules is comparable to the number of binding sites, TF titration will result in correlation (“promoter entanglement”) between transcription of different genes. We develop a statistical mechanical model which takes the TF titration effect into account and use it to predict both the level of gene expression for a general set of promoters and the resulting correlation in transcription rates of different genes. Our results show that the TF titration effect could be important for understanding gene expression in many regulatory settings. PMID:24580252

  18. Treatment discontinuation and tolerability as a function of dose and titration of duloxetine in the treatment of major depressive disorder.

    PubMed

    Harada, Eiji; Shirakawa, Osamu; Satoi, Yoichi; Marangell, Lauren B; Escobar, Rodrigo

    2016-01-01

    We sought to better understand how dose and titration with duloxetine treatment may impact tolerability and treatment discontinuation in patients with major depressive disorder. We investigated Phase III duloxetine trials. Group 1 was a single placebo-controlled study with a 20 mg initial dose and a slow titration to 40 and 60 mg. Group 2 was a single study with a 40 mg initial dose and final "active" doses of 40 and 60 mg (5 mg control group), with 1-week titration. Group 3 consisted of eight placebo-controlled studies with starting doses of 40, 60, and 80 mg/day with minimal titration (final dose 40-120 mg/day). Tolerability was measured by rate of discontinuation due to adverse events (DCAE). The DCAE in Group 1 were 3.6% in the 60 mg group, 3.3% in the 40 mg group, and 3.2% in the placebo group. In Group 2, the DCAE were 15.0% in the 60 mg group, 8.1% in the 40 mg group, and 4.9% in the 5 mg group. In Group 3, the DCAE were 9.7% and 4.2% in the duloxetine and placebo groups, respectively. This study suggests that starting dose and titration may have impacted tolerability and treatment discontinuation. A lower starting dose of duloxetine and slower titration may contribute to improving treatment tolerability for patients with major depressive disorder.

  19. Comparative study of titrated oral misoprostol solution and vaginal dinoprostone for labor induction at term pregnancy.

    PubMed

    Wang, Xiu; Yang, Aijun; Ma, Qingyong; Li, Xuelan; Qin, Li; He, Tongqiang

    2016-09-01

    To evaluate effectiveness and safety of titrated oral misoprostol solution (OMS) in comparison with vaginal dinoprostone for cervix ripening and labor induction in term pregnant women. A multicenter randomized controlled trial of women with term singleton pregnancy with indications for labor induction; 481 participants were allocated to receive titrated OMS with different doses by hourly administration according to the procedure or insert vaginal dinoprostone for cervix ripening and labor induction to compare maternal outcomes including indication of labor induction, mode of outcome of delivery, maternal morbidity, and neonatal outcomes between two groups for evaluating the efficacy and safety of titrated oral misoprostol induction. Proportion of delivery within 12 h of titrated oral misoprostol is significantly less than vaginal dinoprostone (p = 0.03), but no difference of total vaginal delivery rate (p = 0.93); the mean time of first treatment to vaginal delivery was longer in OMS group (21.3 ± 14.5 h) compared with the vaginal dinoprostone group (15.7 ± 9.6 h). Although the proportion of cesarean section between the two groups showed no statistically significant difference, OMS group showed significantly lower frequency of uterine hyperstimulation, hypertonus, partus precipitatus and non-reassuring fetal heart rate than dinoprostone group. Neonatal outcomes were similar evaluating from Apgar score and NICU admission. Our study also showed that labor induction of women with cervix Bishop score ≤3 needed increased dosage of misoprostol solution. Titrated OMS is as effective as vaginal dinoprostone in labor induction for term pregnant women, with safer effect for its lower rate of adverse effect for women.

  20. Spasmodic dysphonia: a seven-year audit of dose titration and demographics in the Indian population.

    PubMed

    Nerurkar, N K; Banu, T P

    2014-07-01

    This study aimed to evaluate the demographics of spasmodic dysphonia in the Indian population and to analyse the optimum dose titration of botulinum toxin type A in this group. A comparative analysis with international studies was also performed. The study involved a retrospective analysis and audit of botulinum toxin type A dose titration in spasmodic dysphonia patients who visited our voice clinic between January 2005 and January 2012. The average total therapeutic dose required for patients with adductor spasmodic dysphonia was 4.2 U per patient per vocal fold (total 8.4 U per patient), and for patients with abductor spasmodic dysphonia, it was 4.6 U per patient. Our audit revealed that 80 per cent of the spasmodic dysphonia patients were male, which contrasts dramatically with international studies, wherein around 80 per cent of spasmodic dysphonia patients were female. Our study also revealed a higher dose titration of botulinum toxin for the Indian spasmodic dysphonia population in both adductor and abductor spasmodic dysphonia cases.

  1. Microelectrode generator-collector systems for electrolytic titration: theoretical and practical considerations.

    PubMed

    Bell, Christopher G; Seelanan, Parinya; O'Hare, Danny

    2017-10-23

    Electochemical generator-collector systems, where one electrode is used to generate a reagent, have a potentially large field of application in sensing and measurement. We present a new theoretical description for coplanar microelectrode disc-disc systems where the collector is passive (such as a potentiometric sensor) and the generator is operating at constant flux. This solution is then used to develop a leading order solution for such a system where the reagent reacts reversibly in solution, such as in acid-base titration, where a hydrogen ion flux is generated by electrolysis of water. The principal novel result of the theory is that such devices are constrained by a maximum reagent flux. The hydrogen ion concentration at the collector will only reflect the buffer capacity of the bulk solution if this constraint is met. Both mathematical solutions are evaluated with several microfabricated devices and reasonable agreement with theory is demonstrated.

  2. A modified two-point titration method for the determination of volatile fatty acids in anaerobic systems.

    PubMed

    Mu, Zhe-Xuan; He, Chuan-Shu; Jiang, Jian-Kai; Zhang, Jie; Yang, Hou-Yun; Mu, Yang

    2018-08-01

    The volatile fatty acids (VFA) concentration plays important roles in the rapid start-up and stable operation of anaerobic reactors. It's essential to develop a simple and accurate method to monitor the VFA concentration in the anaerobic systems. In present work, a modified two-point titration method was developed to determine the VFA concentration. The results show that VFA concentration in standard solutions estimated by the titration method coincided well with that measured by gas chromatograph, where all relative errors were lower than 5.5%. Compared with the phosphate, ammonium and sulfide subsystems, the effect of bicarbonate on the accuracy of the developed method was relatively significant. When the bicarbonate concentration varied from 0 to 8 mmol/L, the relative errors increased from 1.2% to 30% for VFA concentration at 1 mmol/L, but were within 2.0% for that at 5 mmol/L. In addition, the VFA composition affected the accuracy of the titration method to some extent. This developed titration method was further proved to be effective with practical effluents from a lab-scale anaerobic reactor under organic shock loadings and an unstable full-scale anaerobic reactor. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. [Computer modeling the hydrostatic pressure characteristics of the membrane potential for polymeric membrane, separated non-homogeneous electrolyte solutions].

    PubMed

    Slezak, Izabella H; Jasik-Slezak, Jolanta; Rogal, Mirosława; Slezak, Andrzej

    2006-01-01

    On the basis of model equation depending the membrane potential deltapsis, on mechanical pressure difference (deltaP), concentration polarization coefficient (zetas), concentration Rayleigh number (RC) and ratio concentration of solutions separated by membrane (Ch/Cl), the characteristics deltapsis = f(deltaP)zetas,RC,Ch/Cl for steady values of zetas, RC and Ch/Cl in single-membrane system were calculated. In this system neutral and isotropic polymeric membrane oriented in horizontal plane, the non-homogeneous binary electrolytic solutions of various concentrations were separated. Nonhomogeneity of solutions is results from creations of the concentration boundary layers on both sides of the membrane. Calculations were made for the case where on a one side of the membrane aqueous solution of NaCl at steady concentration 10(-3) mol x l(-1) (Cl) was placed and on the other aqueous solutions of NaCl at concentrations from 10(-3) mol x l(-1) to 2 x 10(-2) mol x l(-1) (Ch). Their densities were greater than NaCl solution's at 10(-3) mol x l(-1). It was shown that membrane potential depends on hydrodynamic state of a complex concentration boundary layer-membrane-concentration boundary layer, what is controlled by deltaP, Ch/Cl, RC and zetas.

  4. Thermometric titration of thorium with EDTA in the presence of large excess of neutral sodium salts.

    PubMed

    Doi, K

    1980-11-01

    The thermometric titration of Th(IV) in the presence of neutral sodium salts, sulphuric acid or acetic acid with EDTA has been studied. The effect of each on the observed heat values for the titration is discussed. For sodium perchlorate media, DeltaH values of -9 and -21 kJ/mole have been estimated for the formation of the Th(IV)-EDTA chelate at mu --> 0 and mu = 0.5 (NaClO(4)), respectively. The -DeltaH values increase steadily with increase in concentration of sodium perchlorate up to at least 3M. For the titration of Th(IV) in the presence of a large excess of sodium nitrate the use of sodium iodide as a masking reagent has been examined: large amounts of Bi and Cu(II) are masked and a masking effect is observed for small amounts of Ni.

  5. Empiric Auto-Titrating CPAP in People with Suspected Obstructive Sleep Apnea

    PubMed Central

    Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A.; Gilbert, Gregory E.; Strange, Charlie; Herpel, Laura; Frye, Michael D.

    2010-01-01

    Objective: Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Methods: Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. Results: One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of −3.2 (confidence interval −1.6 to −4.8, p < 0.001) and FOSQ scores improved by a mean of 1.5, (confidence interval 0.5 to 2.7, p = 0.02), whereas scores in the usual-care group did not change (p = NS). Following therapy directed by overnight polysomnography in the control group, there were no differences in ESS or FOSQ between the groups. No adverse events were observed. Conclusion: Empiric auto-CPAP resulted in symptomatic improvement of daytime sleepiness and sleep-related quality of life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional

  6. Lysine N[superscript zeta]-Decarboxylation Switch and Activation of the [beta]-Lactam Sensor Domain of BlaR1 Protein of Methicillin-resistant Staphylococcus aureus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borbulevych, Oleg; Kumarasiri, Malika; Wilson, Brian

    The integral membrane protein BlaR1 of methicillin-resistant Staphylococcus aureus senses the presence of {beta}-lactam antibiotics in the milieu and transduces the information to the cytoplasm, where the biochemical events that unleash induction of antibiotic resistance mechanisms take place. We report herein by two-dimensional and three-dimensional NMR experiments of the sensor domain of BlaR1 in solution and by determination of an x-ray structure for the apo protein that Lys-392 of the antibiotic-binding site is posttranslationally modified by N{sup {zeta}}-carboxylation. Additional crystallographic and NMR data reveal that on acylation of Ser-389 by antibiotics, Lys-392 experiences N{sup {zeta}}-decarboxylation. This unique process, termed themore » lysine N{sup {zeta}}-decarboxylation switch, arrests the sensor domain in the activated ('on') state, necessary for signal transduction and all the subsequent biochemical processes. We present structural information on how this receptor activation process takes place, imparting longevity to the antibiotic-receptor complex that is needed for the induction of the antibiotic-resistant phenotype in methicillin-resistant S. aureus.« less

  7. Titration of Monoprotic Acids with Sodium Hydroxide Contaminated by Sodium Carbonate.

    ERIC Educational Resources Information Center

    Michalowski, Tadeusz

    1988-01-01

    Discusses the effects of using carbon dioxide contaminated sodium hydroxide solution as a titrant for a solution of a weak monoprotic acid and the resulting distortion of the titration curve in comparison to one obtained when an uncontaminated titrant is used. (CW)

  8. Avian influenza virus isolation, propagation and titration in embryonated chicken eggs

    USDA-ARS?s Scientific Manuscript database

    Avian influenza (AI) virus is usually isolated, propagated, and titrated in embryonated chickens eggs (ECE). Most any sample type can be accommodated for culture with appropriate processing. Isolation may also be accomplished in cell culture particularly if mammalian lineage isolates are suspected, ...

  9. Effects of positive end-expiratory pressure titration and recruitment maneuver on lung inflammation and hyperinflation in experimental acid aspiration-induced lung injury.

    PubMed

    Ambrosio, Aline M; Luo, Rubin; Fantoni, Denise T; Gutierres, Claudia; Lu, Qin; Gu, Wen-Jie; Otsuki, Denise A; Malbouisson, Luiz M S; Auler, Jose O C; Rouby, Jean-Jacques

    2012-12-01

    In acute lung injury positive end-expiratory pressure (PEEP) and recruitment maneuver are proposed to optimize arterial oxygenation. The aim of the study was to evaluate the impact of such a strategy on lung histological inflammation and hyperinflation in pigs with acid aspiration-induced lung injury. Forty-seven pigs were randomly allocated in seven groups: (1) controls spontaneously breathing; (2) without lung injury, PEEP 5 cm H2O; (3) without lung injury, PEEP titration; (4) without lung injury, PEEP titration + recruitment maneuver; (5) with lung injury, PEEP 5 cm H2O; (6) with lung injury, PEEP titration; and (7) with lung injury, PEEP titration + recruitment maneuver. Acute lung injury was induced by intratracheal instillation of hydrochloric acid. PEEP titration was performed by incremental and decremental PEEP from 5 to 20 cm H2O for optimizing arterial oxygenation. Three recruitment maneuvers (pressure of 40 cm H2O maintained for 20 s) were applied to the assigned groups at each PEEP level. Proportion of lung inflammation, hemorrhage, edema, and alveolar wall disruption were recorded on each histological field. Mean alveolar area was measured in the aerated lung regions. Acid aspiration increased mean alveolar area and produced alveolar wall disruption, lung edema, alveolar hemorrhage, and lung inflammation. PEEP titration significantly improved arterial oxygenation but simultaneously increased lung inflammation in juxta-diaphragmatic lung regions. Recruitment maneuver during PEEP titration did not induce additional increase in lung inflammation and alveolar hyperinflation. In a porcine model of acid aspiration-induced lung injury, PEEP titration aimed at optimizing arterial oxygenation, substantially increased lung inflammation. Recruitment maneuvers further improved arterial oxygenation without additional effects on inflammation and hyperinflation.

  10. A digital image-based method for determining of total acidity in red wines using acid-base titration without indicator.

    PubMed

    Tôrres, Adamastor Rodrigues; Lyra, Wellington da Silva; de Andrade, Stéfani Iury Evangelista; Andrade, Renato Allan Navarro; da Silva, Edvan Cirino; Araújo, Mário César Ugulino; Gaião, Edvaldo da Nóbrega

    2011-05-15

    This work proposes the use of digital image-based method for determination of total acidity in red wines by means of acid-base titration without using an external indicator or any pre-treatment of the sample. Digital images present the colour of the emergent radiation which is complementary to the radiation absorbed by anthocyanines present in wines. Anthocyanines change colour depending on the pH of the medium, and from the variation of colour in the images obtained during titration, the end point can be localized with accuracy and precision. RGB-based values were employed to build titration curves, and end points were localized by second derivative curves. The official method recommends potentiometric titration with a NaOH standard solution, and sample dilution until the pH reaches 8.2-8.4. In order to illustrate the feasibility of the proposed method, titrations of ten red wines were carried out. Results were compared with the reference method, and no statistically significant difference was observed between the results by applying the paired t-test at the 95% confidence level. The proposed method yielded more precise results than the official method. This is due to the trivariate nature of the measurements (RGB), associated with digital images. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Differential electrolytic potentiometric titration method for the determination of ciprofloxacin in drug formulations.

    PubMed

    Abulkibash, Abdalla M; Sultan, Salah M; Al-Olyan, Abeer M; Al-Ghannam, Sheikha M

    2003-10-17

    A simple and rapid differential electrolytic potentiometric titration method for the determination of ciprofloxacin was developed. The work is based on the fast complexation reaction between iron(III) and ciprofloxacin in a ratio of 1:3, respectively, in sulfuric acid media of 0.09 mol dm(-3). Among the electrodes tested silver amalgam electrodes were found to be a suitable indicating system. By applying a current density of 0.5 muA cm(-2) to these electrodes and using iron(III) solution of 0.097 mol dm(-3) as a titrant, normal titration curves were obtained. The method was successfully applied for the determination of ciprofloxacin in drug formulations as low as 4.0 ppm.

  12. Origin of two time-scale regimes in potentiometric titration of metal oxides. A replica kinetic Monte Carlo study.

    PubMed

    Zarzycki, Piotr; Rosso, Kevin M

    2009-06-16

    Replica kinetic Monte Carlo simulations were used to study the characteristic time scales of potentiometric titration of the metal oxides and (oxy)hydroxides. The effect of surface heterogeneity and surface transformation on the titration kinetics were also examined. Two characteristic relaxation times are often observed experimentally, with the trailing slower part attributed to surface nonuniformity, porosity, polymerization, amorphization, and other dynamic surface processes induced by unbalanced surface charge. However, our simulations show that these two characteristic relaxation times are intrinsic to the proton-binding reaction for energetically homogeneous surfaces, and therefore surface heterogeneity or transformation does not necessarily need to be invoked. However, all such second-order surface processes are found to intensify the separation and distinction of the two kinetic regimes. The effect of surface energetic-topographic nonuniformity, as well dynamic surface transformation, interface roughening/smoothing were described in a statistical fashion. Furthermore, our simulations show that a shift in the point-of-zero charge is expected from increased titration speed, and the pH-dependence of the titration measurement error is in excellent agreement with experimental studies.

  13. Labour induction at term--a randomised trial comparing Foley catheter plus titrated oral misoprostol solution, titrated oral misoprostol solution alone, and dinoprostone.

    PubMed

    Matonhodze, Baron B; Hofmeyr, G Justus; Levin, Jonathan

    2003-05-01

    To compare three methods of labour induction. Randomised controlled trial. Academic hospitals in Johannesburg, South Africa. Women with intact membranes due for induction of labour. Randomised, sealed opaque envelopes were used to allocate women to labour induction with extra-amniotic Foley catheter/titrated oral misoprostol solution (N = 174), titrated oral misoprostol solution alone (N = 176), or vaginal dinoprostone (N = 176). Misoprostol was dissolved in water and 20-40 g was given 2-hourly. These were failure to deliver vaginally within 24 hours, additional measures for induction or augmentation of labour, analgesia, and maternal and fetal complications. In the Foley catheter group, misoprostol was required in all but 1 case. Failure to deliver vaginally within 24 hours was similar for the three groups (79/174 v. 70/176 v. 70/176 respectively). Labour augmentation, caesarean section and instrumental delivery were used somewhat more frequently in the Foley/misoprostol group than in the misoprostol alone group, but these differences were not statistically significant. More analgesia was used in the Foley catheter/misoprostol group than in the misoprostol group (64/172 v. 46/175). Side-effects and neonatal complications were similar for the three groups. Use of extra-amniotic Foley catheter placement showed no measurable benefits over the use of oral misoprostol alone, or vaginal dinoprostone.

  14. Titration of a Solid Acid Monitored by X-Ray Diffraction

    ERIC Educational Resources Information Center

    Dungey, Keenan E.; Epstein, Paul

    2007-01-01

    An experiment is described to introduce students to an important class of solid-state reactions while reinforcing concepts of titration by using a pH meter and a powder X-ray diffractometer. The experiment was successful in teaching students the abstract concepts of solid-state structure and diffraction by applying the diffraction concepts learned…

  15. Functional Role of Tyr12 in the Catalytic Activity of Novel Zeta-like Glutathione S-transferase from Acidovorax sp. KKS102.

    PubMed

    Shehu, Dayyabu; Alias, Zazali

    2018-05-19

    Glutathione S-transferases (GSTs) are a family of enzymes that function in the detoxification of variety of electrophilic substrates. In the present work, we report a novel zeta-like GST (designated as KKSG9) from the biphenyl/polychlorobiphenyl degrading organism Acidovorax sp. KKS102. KKSG9 possessed low sequence similarity but similar biochemical properties to zeta class GSTs. Functional analysis showed that the enzyme exhibits wider substrate specificity compared to most zeta class GSTs by reacting with 1-chloro-2,4-dinitrobenzene (CDNB), p-nitrobenzyl chloride (NBC), ethacrynic acid (EA), hydrogen peroxide, and cumene hydroperoxide. The enzyme also displayed dehalogenation function against dichloroacetate, permethrin, and dieldrin. The functional role of Tyr12 was also investigated by site-directed mutagenesis. The mutant (Y12C) displayed low catalytic activity and dehalogenation function against all the substrates when compared with the wild type. Kinetic analysis using NBC and GSH as substrates showed that the mutant (Y12C) displayed a higher affinity for NBC when compared with the wild type, however, no significant change in GSH affinity was observed. These findings suggest that the presence of tyrosine residue in the motif might represent an evolutionary trend toward improving the catalytic activity of the enzyme. The enzyme as well could be useful in the bioremediation of various types of organochlorine pollutants.

  16. Subsite binding energies of an exo-polygalacturonase using isothermal titration calorimetry

    USDA-ARS?s Scientific Manuscript database

    Thermodynamic parameters for binding of a series of galacturonic acid oligomers to an exo-polygalacturonase, RPG16 from Rhizopus oryzae, were determined by isothermal titration calorimetry. Binding of oligomers varying in chain length from two to five galacturonic acid residues is an exothermic proc...

  17. Zinc sorption to three gram-negative bacteria: combined titration, modeling, and EXAFS study.

    PubMed

    Guiné, V; Spadini, L; Sarret, G; Muris, M; Delolme, C; Gaudet, J P; Martins, J M F

    2006-03-15

    The acid-base and Zn sorption properties of three bacteria, Cupriavidus metallidurans CH34, Pseudomonas putida ATCC12633, and Escherichia coli K12DH5alpha, were investigated through an original combination of extended X-ray absorption fine structure (EXAFS) spectroscopy and equilibrium titration studies. Acid-base titration curves of the three strains were fitted with a model accounting for three conceptual reactive sites: an acidic (carboxyl and/or phosphodiester), a neutral (phosphomonoester), and a basic (amine and/or hydroxyl) group. Calculated proton and Zn equilibrium constants and site densities compare with literature data. The nature of Zn binding sites was studied by EXAFS spectroscopy. Phosphoester, carboxyl, and unexpectedly sulfhydryl ligands were identified. Their proportions depended on Zn loading and bacterial strain and were consistent with the titration results. These findings were compared to the structure and site density of the major cell wall components. It appeared that the cumulated theoretical site density of these structures (<2 Zn nm(-2)) was much lower than the total site density of the investigated strains (16-56 Zn nm(-2)). These results suggest a dominant role of extracellular polymeric substances in Zn retention processes, although Zn binding to inner cell components cannot be excluded.

  18. Common Standards of Basal Insulin Titration in T2DM

    PubMed Central

    Arnolds, Sabine; Heise, Tim; Flacke, Frank; Sieber, Jochen

    2013-01-01

    Type 2 diabetes mellitus has become a worldwide major health problem, and the number of people affected is steadily increasing. Thus, not all patients suffering from the disease can be treated by specialized diabetes centers or outpatient clinics, but by primary care physicians. The latter, however, might have time constraints and have to deal with many kinds of diseases or with multimorbid patients, so their focus is not so much on lowering high blood glucose values. Thus, the physicians, as well as the patients themselves, are often reluctant to initiate and adjust insulin therapy, although basal insulin therapy is considered the appropriate strategy after oral antidiabetic drug failure, according to the latest international guidelines. A substantial number of clinical studies have shown that insulin initiation and optimization can be managed successfully by using titration algorithms—even in cases where patients themselves are the drivers of insulin titration. Nevertheless, tools and strategies are needed to facilitate this process in the daily life of both primary health care professionals and patients with diabetes. PMID:23759411

  19. Field ion microscopic studies of the CO oxidation on platinum: Field ion imaging and titration reactions

    NASA Astrophysics Data System (ADS)

    Gorodetskii, V.; Drachsel, W.; Block, J. H.

    1994-05-01

    Elementary steps of the CO oxidation—which are important for understanding the oscillatory behavior of this catalytic reaction—are investigated simultaneously on different Pt-single crystal surfaces by field ion microscopy. Due to preferential ionization probabilities of oxygen as imaging gas on those surface sites, which are adsorbed with oxygen, these sites can be imaged in a lateral resolution on the atomic scale. In the titration reaction a COad-precovered field emitter surface reacts with gaseous oxygen adsorbed from the gas phase or, vice versa, the Oad-precovered surface with carbon monoxide adsorbed from the gas phase. The competition of the manifold of single crystal planes exposed to the titration reaction at the field emitter tip is studied. The surface specificity can be documented in the specific reaction delay times of the different planes and in the propagation rates of the reaction-diffusion wave fronts measured on these individual planes during the titration reaction with a time resolution of 40 ms. At 300 K the COad-precovered surfaces display the {011} regions, precisely the {331} planes as the most active, followed by {012}, {122}, {001}, and finally by {111}. Reaction wave fronts move with a velocity of 8 Å/s at {012}, with ≊0.8 Å/s at {111}, and have a very fast ``switch-on'' reaction at the (001) plane with 500 Å/s. At higher temperature, T=350 K, an acceleration of reaction rates is combined with shorter delay times. The titration reaction of a precovered Oad surface with COgas at T=373 K shows the formation of CO islands starting in the {011} regions with a quickly moving reaction front into the other surface areas without showing particular delay times for different surface symmetries. The two reverse titration reactions have a largely different character. The titration of COad with oxygen adsorbed from the gas phase consists of three different steps, (i) the induction times, (ii) the highly surface specific reaction, and (iii

  20. Complexation Effect on Redox Potential of Iron(III)-Iron(II) Couple: A Simple Potentiometric Experiment

    ERIC Educational Resources Information Center

    Rizvi, Masood Ahmad; Syed, Raashid Maqsood; Khan, Badruddin

    2011-01-01

    A titration curve with multiple inflection points results when a mixture of two or more reducing agents with sufficiently different reduction potentials are titrated. In this experiment iron(II) complexes are combined into a mixture of reducing agents and are oxidized to the corresponding iron(III) complexes. As all of the complexes involve the…

  1. Consensus on Insulin Dose and Titration Algorithms in Ambulatory Care of Type 2 Diabetes in India.

    PubMed

    Kovil, Rajiv; Chawla, Manoj; Rajput, Rajesh; Singh, A K; Sinha, Binayak; Ghosal, Samit; Ballani, Piya; Gupta, Sunil; Tanna, Snehal; Bandukwala, S M; Shah, Tejas; Negalur, Vijay; Bhoraskar, Anil; Aravind, S R; Zargar, Abdul H; Kesavadev, Jothydev; Das, Ashok Kumar

    2017-02-01

    Insulin is the oldest of the currently available treatment options in Type 2 diabetes mellitus (T2DM) and is considered as the most effective glucose lowering agent. Despite this, decision on starting insulin therapy is often delayed in India as well as worldwide due to various barriers at both patient and physician levels. Appropriate insulin dosing and titration is also critical to the successful achievement of tight glycaemic control. To provide simple and easily implementable guidelines to primary care physicians on appropriate insulin dosing and titration of various insulin regimens for both initiation and intensification. Each insulin regimen (once daily [OD] basal, OD, twice daily and thrice daily premixed, basal-plus and basal-bolus) was presented and evaluated for dosing and titration based on established guidelines, data from approved pack inserts, and published scientific literature. These evaluations were then factored into the national context based on the expert committee representatives patient-physician experience in their clinical practice and common therapeutic practices followed in India. Recommendations for dosing and titration of basal, basal-plus, premixed and basal-bolus insulins were developed. The key recommendations are that insulin doses can be adjusted once or twice weekly; adjustment can be based on lowest/mean of three recent self-monitoring of plasma glucose pre-meal/fasting plasma glucose (FPG) values. The titration should be based on FPG or pre-meal value of 80-130 mg/dL and the dose should be reduced by 10-20% for patients reporting hypoglycaemia(<70mg/dL). The consensus based recommendations mentioned in this paper will be a useful reference tool for health care practitioners, to initiate, optimise and intensify insulin therapy and to successfully achieve optimal glucose control.

  2. Randomized cross-over trial of ventilator modes during non-invasive ventilation titration in amyotrophic lateral sclerosis.

    PubMed

    Vrijsen, Bart; Buyse, Bertien; Belge, Catharina; Vanpee, Goele; Van Damme, Philip; Testelmans, Dries

    2017-08-01

    Non-invasive ventilation (NIV) improves survival, quality of life and sleep in patients with amyotrophic lateral sclerosis (ALS). Nevertheless, NIV titration is conducted in different ways. We aim to provide more insight into NIV titration by comparing the effects of a spontaneous (S) and spontaneous-timed (ST) modes on gas exchange, sleep architecture and patient-ventilator asynchronies (PVAs). After an initial night of NIV titration, patients were randomized to S or ST mode in a cross-over design. NIV was titrated using polysomnography, oximetry (oxygen saturation, SpO 2 %) and transcutaneous carbon dioxide (PtcCO 2 ) measurement. PVAs were analysed breath-by-breath. Thirteen patients were analysed after inclusion. ST mode showed better results in gas exchange (minimal SpO 2 %: 83 (80-89)% vs 87 (84-89)%; oxygen desaturation index: 15 (5-28)/h sleep vs 7 (3-9)/h sleep; PtcCO 2 >55 mm Hg: 20 (0-59)% vs 0 (0-27)% total sleep time for S and ST mode, respectively, all P < 0.05) and respiratory events (obstructive: 8.9 (1.2-18.3)/h sleep vs 1.8 (0.3-4.9)/h sleep and central: 2.6 (0.4-14.1)/h sleep vs 0.2 (0.0-1.1)/h sleep for S and ST mode, respectively, both P < 0.01). No differences in sleep architecture were found. Ineffective efforts and respiratory events were more frequently present in S mode. Nevertheless, four patients were discharged on S mode as these patients showed clinically better results for sleep architecture and PVA during the night on S mode. ST mode shows better results in gas exchange, respiratory events and PVA. Nevertheless, accurate NIV titration remains necessary as some patients show equal or better results when using the S mode. © 2017 Asian Pacific Society of Respirology.

  3. The Simulation of an Oxidation-Reduction Titration Curve with Computer Algebra

    ERIC Educational Resources Information Center

    Whiteley, Richard V., Jr.

    2015-01-01

    Although the simulation of an oxidation/reduction titration curve is an important exercise in an undergraduate course in quantitative analysis, that exercise is frequently simplified to accommodate computational limitations. With the use of readily available computer algebra systems, however, such curves for complicated systems can be generated…

  4. Electrophoretic separation of alginic sodium diester and sodium hexametaphosphate in chondroitin sulfate that interfere with the cetylpyridinium chloride titration assay.

    PubMed

    Weiguo, Zhang; Giancaspro, Gabriel; Adams, Kristie M; Neal-Kababick, James; Hildreth, Jana; Li, Aishan; Roman, Mark C; Betz, Joseph M

    2014-01-01

    The most commonly used chondroitin sulfate (CS) assay method is cetylpyridinium chloride (CPC) titration. Cellulose acetate membrane electrophoresis (CAME) is the technique used for detection of impurities in the U.S. Pharmacopeia's CS monograph. Because CPC titration is a relatively nonspecific quantitative technique, the apparent amount of CS as determined by CPC titration alone may not reflect the true amount of CS due to possible interference with the CPC assay by impurities that contain CPC titratable functional groups. When CAME is used in conjunction with CPC titration, certain non-CS and adulterants can be visualized and estimated, and a true value for CS can be assigned once the presence of these non-CS impurities has been ruled out. This study examines conjunct application of CPC and CAME in ascertaining CS assay and purity in the presence of certain adulterants. These include propylene glycol alginate sulfate sodium, known in commerce as alginic sodium diester (ASD), and Zero One (Z1), a water-soluble agent newly reported in the CS marketplace and subsequently identified as sodium hexametaphosphate. ASD, Z1, and CS are similar in physical appearance and solubility in water and ethanol. They are also titratable anions and form ionic pairs with CPC, therefore interfering with the CPC titration assay for CS CAME separates these adulterants from each other and from CS by differences in their electrophoretic mobility. CAME is able to detect these impurities in CS at levels as low as 0.66% by weight. Although it is recommended that a method for detecting impurities (e.g., CAME) be used in cormbination with relatively nonspecific assay methods such as CPC titration, this is seldom done in practice. Assay results for CS derived fromn CPC titration may, therefore, be misleading, leaving the CS supply chain vulnerable to adulteration. In this study, the authors investigated ASD and Z1 adulteration of CS and developed an electrophoretic separation of these

  5. Fluorometric titration approach for calibration of quantity of binding site of purified monoclonal antibody recognizing epitope/hapten nonfluorescent at 340 nm.

    PubMed

    Yang, Xiaolan; Hu, Xiaolei; Xu, Bangtian; Wang, Xin; Qin, Jialin; He, Chenxiong; Xie, Yanling; Li, Yuanli; Liu, Lin; Liao, Fei

    2014-06-17

    A fluorometric titration approach was proposed for the calibration of the quantity of monoclonal antibody (mcAb) via the quench of fluorescence of tryptophan residues. It applied to purified mcAbs recognizing tryptophan-deficient epitopes, haptens nonfluorescent at 340 nm under the excitation at 280 nm, or fluorescent haptens bearing excitation valleys nearby 280 nm and excitation peaks nearby 340 nm to serve as Förster-resonance-energy-transfer (FRET) acceptors of tryptophan. Titration probes were epitopes/haptens themselves or conjugates of nonfluorescent haptens or tryptophan-deficient epitopes with FRET acceptors of tryptophan. Under the excitation at 280 nm, titration curves were recorded as fluorescence specific for the FRET acceptors or for mcAbs at 340 nm. To quantify the binding site of a mcAb, a universal model considering both static and dynamic quench by either type of probes was proposed for fitting to the titration curve. This was easy for fitting to fluorescence specific for the FRET acceptors but encountered nonconvergence for fitting to fluorescence of mcAbs at 340 nm. As a solution, (a) the maximum of the absolute values of first-order derivatives of a titration curve as fluorescence at 340 nm was estimated from the best-fit model for a probe level of zero, and (b) molar quantity of the binding site of the mcAb was estimated via consecutive fitting to the same titration curve by utilizing such a maximum as an approximate of the slope for linear response of fluorescence at 340 nm to quantities of the mcAb. This fluorometric titration approach was proved effective with one mcAb for six-histidine and another for penicillin G.

  6. Characterization of acid-base properties of two gibbsite samples in the context of literature results.

    PubMed

    Adekola, F; Fédoroff, M; Geckeis, H; Kupcik, T; Lefèvre, G; Lützenkirchen, J; Plaschke, M; Preocanin, T; Rabung, T; Schild, D

    2011-02-01

    Two different gibbsites, one commercial and one synthesized according to a frequently applied recipe, were studied in an interlaboratory attempt to gain insight into the origin of widely differing reports on gibbsite acid-base surface properties. In addition to a thorough characterization of the two solids, several methods relevant to the interfacial charging were applied to the two samples: potentiometric titrations to obtain the "apparent" proton related surface charge density, zeta-potential measurements characterizing the potential at the plane of shear, and Attenuated Total Reflection Infrared Spectroscopy (ATR-IR) to obtain information on the variation of counter-ion adsorption with pH (using nitrate as a probe). Values of the IEP at 9-10 and 11.2-11.3 were found for the commercial and synthesized sample, respectively. The experimental observations revealed huge differences in the charging behavior between the two samples. Such differences also appeared in the titration kinetics. A detailed literature review revealed similar disparity with no apparent systematic trend. While previously the waiting time between additions had been advocated to explain such differences among synthesized samples, our results do not support such a conclusion. Instead, we find that the amount of titrant added in each aliquot appears to have a significant influence on the titration curves. While we can relate a number of observations to others, a number of open questions and contradictions remain. We suggest various processes, which can explain the observed behavior. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. The structure of a zeta class glutathione S-transferase from Arabidopsis thaliana: characterisation of a GST with novel active-site architecture and a putative role in tyrosine catabolism.

    PubMed

    Thom, R; Dixon, D P; Edwards, R; Cole, D J; Lapthorn, A J

    2001-05-18

    The cis-trans isomerisation of maleylacetoacetate to fumarylacetoacetate is the penultimate step in the tyrosine/phenylalanine catabolic pathway and has recently been shown to be catalysed by glutathione S-transferase enzymes belonging to the zeta class. Given this primary metabolic role it is unsurprising that zeta class glutathione S-transferases are well conserved over a considerable period of evolution, being found in vertebrates, plants, insects and fungi. The structure of this glutathione S-transferase, cloned from Arabidopsis thaliana, has been solved by single isomorphous replacement with anomalous scattering and refined to a final crystallographic R-factor of 19.6% using data from 25.0 A to 1.65 A. The zeta class enzyme adopts the canonical glutathione S-transferase fold and forms a homodimer with each subunit consisting of 221 residues. In agreement with structures of glutathione S-transferases from the theta and phi classes, a serine residue (Ser17) is present in the active site, at a position that would allow it to stabilise the thiolate anion of glutathione. Site-directed mutagenesis of this residue confirms its importance in catalysis. In addition, the role of a highly conserved cysteine residue (Cys19) present in the active site of the zeta class glutathione S-transferase enzymes is discussed. Copyright 2001 Academic Press.

  8. Design of a multicentre randomized controlled trial to assess the safety and efficacy of dose titration by specialized nurses in patients with heart failure. ETIFIC study protocol.

    PubMed

    Oyanguren, Juana; García-Garrido, LLuisa; Nebot Margalef, Magdalena; Lekuona, Iñaki; Comin-Colet, Josep; Manito, Nicolás; Roure, Julia; Ruiz Rodriguez, Pilar; Enjuanes, Cristina; Latorre, Pedro; Torcal Laguna, Jesús; García-Gutiérrez, Susana

    2017-11-01

    Heart failure (HF) is associated with many hospital admissions and relatively high mortality, rates decreasing with administration of beta-blockers (BBs), angiotensin-converting-enzyme inhibitors, angiotensin II receptor blockers, and mineralocorticoid receptor antagonists. The effect is dose dependent, suboptimal doses being common in clinical practice. The 2012 European guidelines recommend close monitoring and dose titration by HF nurses. Our main aim is to compare BB doses achieved by patients after 4 months in intervention (HF nurse-managed) and control (cardiologist-managed) groups. Secondary aims include comparing doses of the other aforementioned drugs achieved after 4 months, adverse events, and outcomes at 6 months in the two groups. We have designed a multicentre (20 hospitals) non-inferiority randomized controlled trial, including patients with new-onset HF, left ventricular ejection fraction ≤40%, and New York Heart Association class II-III, with no contraindications to BBs. We will also conduct qualitative analysis to explore potential barriers to and facilitators of dose titration by HF nurses. In the intervention group, HF nurses will implement titration as prescribed by cardiologists, following a protocol. In controls, cardiologists will both prescribe and titrate doses. The study variables are doses of each of the drugs after 4 months relative to the target dose (%), New York Heart Association class, left ventricular ejection fraction, N-terminal pro B-type natriuretic peptide levels, 6 min walk distance, comorbidities, renal function, readmissions, mortality, quality of life, and psychosocial characteristics. The trial seeks to assess whether titration by HF nurses of drugs recommended in practice guidelines is safe and not inferior to direct management by cardiologists. The results could have an impact on clinical practice. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of

  9. Design of a multicentre randomized controlled trial to assess the safety and efficacy of dose titration by specialized nurses in patients with heart failure. ETIFIC study protocol

    PubMed Central

    García‐Garrido, LLuisa; Nebot Margalef, Magdalena; Lekuona, Iñaki; Comin‐Colet, Josep; Manito, Nicolás; Roure, Julia; Ruiz Rodriguez, Pilar; Enjuanes, Cristina; Latorre, Pedro; Torcal Laguna, Jesús; García‐Gutiérrez, Susana

    2017-01-01

    Abstract Aims Heart failure (HF) is associated with many hospital admissions and relatively high mortality, rates decreasing with administration of beta‐blockers (BBs), angiotensin‐converting‐enzyme inhibitors, angiotensin II receptor blockers, and mineralocorticoid receptor antagonists. The effect is dose dependent, suboptimal doses being common in clinical practice. The 2012 European guidelines recommend close monitoring and dose titration by HF nurses. Our main aim is to compare BB doses achieved by patients after 4 months in intervention (HF nurse‐managed) and control (cardiologist‐managed) groups. Secondary aims include comparing doses of the other aforementioned drugs achieved after 4 months, adverse events, and outcomes at 6 months in the two groups. Methods We have designed a multicentre (20 hospitals) non‐inferiority randomized controlled trial, including patients with new‐onset HF, left ventricular ejection fraction ≤40%, and New York Heart Association class II–III, with no contraindications to BBs. We will also conduct qualitative analysis to explore potential barriers to and facilitators of dose titration by HF nurses. In the intervention group, HF nurses will implement titration as prescribed by cardiologists, following a protocol. In controls, cardiologists will both prescribe and titrate doses. The study variables are doses of each of the drugs after 4 months relative to the target dose (%), New York Heart Association class, left ventricular ejection fraction, N‐terminal pro B‐type natriuretic peptide levels, 6 min walk distance, comorbidities, renal function, readmissions, mortality, quality of life, and psychosocial characteristics. Conclusions The trial seeks to assess whether titration by HF nurses of drugs recommended in practice guidelines is safe and not inferior to direct management by cardiologists. The results could have an impact on clinical practice. PMID:29154427

  10. Acid-base titration of melanocortin peptides: evidence of Trp rotational conformers interconversion.

    PubMed

    Fernandez, Roberto M; Vieira, Renata F F; Nakaie, Clóvis R; Lamy, M Teresa; Ito, Amando S

    2005-01-01

    Tryptophantime-resolved fluorescence was used to monitor acid-base titration properties of alpha-melanocyte stimulating hormone (alpha-MSH) and the biologically more potent analog [Nle4, D-Phe7]alpha -MSH (NDP-MSH), labeled or not with the paramagnetic amino acid probe 2,2,6,6-tetramthylpiperidine-N-oxyl-4-amino-4-carboxylic acid (Toac). Global analysis of fluorescence decay profiles measured in the pH range between 2.0 and 11.0 showed that, for each peptide, the data could be well fitted to three lifetimes whose values remained constant. The less populated short lifetime component changed little with pH and was ascribed to Trp g+ chi1 rotamer, in which electron transfer deactivation predominates over fluorescence. The long and intermediate lifetime preexponential factors interconverted along that pH interval and the result was interpreted as due to interconversion between Trp g- and trans chi1 rotamers, driven by conformational changes promoted by modifications in the ionization state of side-chain residues. The differences in the extent of interconversion in alpha-MSH and NDP-MSH are indicative of structural differences between the peptides, while titration curves suggest structural similarities between each peptide and its Toac-labeled species, in aqueous solution. Though less sensitive than fluorescence, the Toac electron spin resonance (ESR) isotropic hyperfine splitting parameter can also monitor the titration of side-chain residues located relatively far from the probe. Copyright (c) 2005 Wiley Periodicals, Inc.

  11. First insights into a type II toxin-antitoxin system from the clinical isolate Mycobacterium sp. MHSD3, similar to epsilon/zeta systems.

    PubMed

    Jaén-Luchoro, Daniel; Aliaga-Lozano, Francisco; Gomila, Rosa Maria; Gomila, Margarita; Salvà-Serra, Francisco; Lalucat, Jorge; Bennasar-Figueras, Antoni

    2017-01-01

    A putative type II toxin-antitoxin (TA) system was found in the clinical isolate Mycobacterium sp. MHSD3, a strain closely related to Mycobacterium chelonae. Further analyses of the protein sequences of the two genes revealed the presence of domains related to a TA system. BLAST analyses indicated the presence of closely related proteins in the genomes of other recently published M. chelonae strains. The functionality of both elements of the TA system was demonstrated when expressed in Escherichia coli cells, and the predicted structure of the toxin is very similar to those of well-known zeta-toxins, leading to the definition of a type II TA system similar to epsilon/zeta TA systems in strains that are closely related to M. chelonae.

  12. Clinical Trials Using Anti-CD19/CD28/CD3zeta CAR Gammaretroviral Vector-transduced Autologous T Lymphocytes KTE-C19

    Cancer.gov

    NCI supports clinical trials that test new and more effective ways to treat cancer. Find clinical trials studying anti-cd19/cd28/cd3zeta car gammaretroviral vector-transduced autologous t lymphocytes kte-c19.

  13. The Quantitative Resolution of a Mixture of Group II Metal Ions by Thermometric Titration with EDTA. An Analytical Chemistry Experiment.

    ERIC Educational Resources Information Center

    Smith, Robert L.; Popham, Ronald E.

    1983-01-01

    Presents an experiment in thermometric titration used in an analytic chemistry-chemical instrumentation course, consisting of two titrations, one a mixture of calcium and magnesium, the other of calcium, magnesium, and barium ions. Provides equipment and solutions list/specifications, graphs, and discussion of results. (JM)

  14. Flow cytometry as an improved method for the titration of Chlamydiaceae and other intracellular bacteria.

    PubMed

    Käser, T; Pasternak, J A; Hamonic, G; Rieder, M; Lai, K; Delgado-Ortega, M; Gerdts, V; Meurens, F

    2016-05-01

    Chlamydiaceae is a family of intracellular bacteria causing a range of diverse pathological outcomes. The most devastating human diseases are ocular infections with C. trachomatis leading to blindness and genital infections causing pelvic inflammatory disease with long-term sequelae including infertility and chronic pelvic pain. In order to enable the comparison of experiments between laboratories investigating host-chlamydia interactions, the infectious titer has to be determined. Titer determination of chlamydia is most commonly performed via microscopy of host cells infected with a serial dilution of chlamydia. However, other methods including fluorescent ELISpot (Fluorospot) and DNA Chip Scanning Technology have also been proposed to enumerate chlamydia-infected cells. For viruses, flow cytometry has been suggested as a superior alternative to standard titration methods. In this study we compared the use of flow cytometry with microscopy and Fluorospot for the titration of C. suis as a representative of other intracellular bacteria. Titer determination via Fluorospot was unreliable, while titration via microscopy led to a linear read-out range of 16 - 64 dilutions and moderate reproducibility with acceptable standard deviations within and between investigators. In contrast, flow cytometry had a vast linear read-out range of 1,024 dilutions and the lowest standard deviations given a basic training in these methods. In addition, flow cytometry was faster and material costs were lower compared to microscopy. Flow cytometry offers a fast, cheap, precise, and reproducible alternative for the titration of intracellular bacteria like C. suis. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.

  15. A titration method for determining individual oxidant concentration in the dual sodium persulfate and hydrogen peroxide oxidation system.

    PubMed

    Liang, Chenju; He, Boyu

    2018-05-01

    The use of a dual oxidation system, which combines sodium persulfate (Na 2 S 2 O 8 , SPS) and hydrogen peroxide (H 2 O 2 , HP) is increasing as an in-situ chemical oxidation (ISCO) process for soil and groundwater remediation. An analytical method was assessed in this study for determining individual oxidant concentration in order to understand the interactions, and variations in the concentrations, of SPS and HP in aqueous systems containing both SPS and HP. The iodometric titration method was demonstrated to be capable of measuring total oxidant (SPS + HP) concentration; while the ceric sulfate titration method can be used specifically for measuring HP in the dual oxidation system without interfering with the iodometric titration. Therefore, SPS concentration can be deduced by subtraction of the HP concentration from the total oxidant concentration. Direct iodometric titration for determination of total oxidant at concentration above 20 mM exhibited <8% concentration. Based on the results of indirect determination of SPS in the dual oxidation system, an approximate 10% concentration variation was expected. This research may serve as a reference for measuring oxidant variations in this ISCO dual oxidant application. Copyright © 2018. Published by Elsevier Ltd.

  16. Optimizing Glycemic Control Through Titration of Insulin Glargine 100 U/mL: A Review of Current and Future Approaches with a Focus on Asian Populations.

    PubMed

    Deerochanawong, Chaicharn; Bajpai, Shailendra; Dwipayana, I Made Pande; Hussein, Zanariah; Mabunay, Maria Aileen; Rosales, Reynaldo; Tsai, Shih-Tzer; Tsang, Man Wo

    2017-12-01

    Various data have demonstrated inadequate glycemic control amongst Asians with type 2 diabetes mellitus (T2DM), possibly on account of suboptimal titration of basal insulin-an issue which needs to be further examined. Here we review the available global and Asia-specific data on titration of basal insulin, with a focus on the use of insulin glargine 100 U/mL (Gla-100). We also discuss clinical evidence on the efficacy and safety of titrating Gla-100, different approaches to titration, including some of the latest technological advancements, and guidance on the titration of basal insulin from international and local Asian guidelines. The authors also provide their recommendations for the initiation and titration of basal insulin for Asian populations. Discussion of the data included in this review and in relation to the authors' clinical experience with treating T2DM in Asian patients is also included. Briefly, clinical studies demonstrate the achievement of adequate glycemic control in adults with T2DM through titration of Gla-100. However, studies investigating approaches to titration, specifically in Asian populations, are lacking and need to be conducted. Given that the management of insulin therapy is a multidisciplinary team effort involving endocrinologists, primary care physicians, nurse educators, and patients, greater resources and education targeted at these groups are needed regarding the optimal titration of basal insulin. Technological advancements in the form of mobile or web-based applications for automated dose adjustment can aid different stakeholders in optimizing the dose of basal insulin, enabling a larger number of patients in Asia to reach their target glycemic goals with improved outcomes.

  17. Semi-automated potentiometric titration method for uranium characterization.

    PubMed

    Cristiano, B F G; Delgado, J U; da Silva, J W S; de Barros, P D; de Araújo, R M S; Lopes, R T

    2012-07-01

    The manual version of the potentiometric titration method has been used for certification and characterization of uranium compounds. In order to reduce the analysis time and the influence of the analyst, a semi-automatic version of the method was developed in the Brazilian Nuclear Energy Commission. The method was applied with traceability assured by using a potassium dichromate primary standard. The combined standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Comparative evaluation of gel column agglutination and erythrocyte magnetized technology for red blood cell alloantibody titration.

    PubMed

    Dubey, Anju; Sonker, Atul; Chaudhary, Rajendra K

    2015-01-01

    Antibody titration is traditionally performed using a conventional test tube (CTT) method, which is subjected to interlaboratory variations because of a lack of standardization and reproducibility. The aim of this study is to compare newer methods such as get column technology (GCT) and erythrocyte magnetized technology (EMT) for antibody titration in terms of accuracy and precision. Patient serum samples that contained immunoglobin G (IgG) red blood cell (RBC) alloantibodies of a single specificity for Rh or K anitgens were identified during routine transfusion service testing and stored. Titration and scoring were performed separately by and stored. Titration and scoring were performed separately by different laboratory personnel on CTT, GCT, and EMT. Testing was performed a total of three times on each sample. Results were analyzed for accuracy and precision. A total of 50 samples were tested. Only 20 percent of samples tested with GCT shoed titers identical to CTT, whereas 48 percent of samples tested with EMT showed titers identical to CTT. Overall, the mean of th titer difference from CTT was higher using GCT (+0.31) compared with that using EMT (+0.13). Precision shown by CTT was 30 percent, EMT was 76 percent, and GCT was 92 percent on repeat testing. GCT showed higher titer values in comparison with CTT but was found to be the most precise. EMT titers were comparable to CTT, and its precision was intermediate. Further studies to validate this method are required.

  19. Thermodynamic investigations of protein's behaviour with ionic liquids in aqueous medium studied by isothermal titration calorimetry.

    PubMed

    Bharmoria, Pankaj; Kumar, Arvind

    2016-05-01

    While a number of reports appear on ionic liquids-proteins interactions, their thermodynamic behaviour using suitable technique like isothermal titration calorimetry is not systematically presented. Isothermal titration calorimetry (ITC) is a key technique which can directly measure the thermodynamic contribution of IL binding to protein, particularly the enthalpy, heat capacities and binding stoichiometry. Ionic liquids (ILs), owing to their unique and tunable physicochemical properties have been the central area of scientific research besides graphene in the last decade, and growing unabated. Their encounter with proteins in the biological system is inevitable considering their environmental discharge though most of them are recyclable for a number of cycles. In this article we will cover the thermodynamics of proteins upon interaction with ILs as osmolyte and surfactant. The up to date literature survey of IL-protein interactions using isothermal titration calorimetry will be discussed and parallel comparison with the results obtained for such studies with other techniques will be highlighted to demonstrate the accuracy of ITC technique. Net stability of proteins can be obtained from the difference in the free energy (ΔG) of the native (folded) and denatured (unfolded) state using the Gibbs-Helmholtz equation (ΔG=ΔH-TΔS). Isothermal titration calorimetry can directly measure the heat changes upon IL-protein interactions. Calculation of other thermodynamic parameters such as entropy, binding constant and free energy depends upon the proper fitting of the binding isotherms using various fitting models. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Randomized clinical trial of an intravenous hydromorphone titration protocol versus usual care for management of acute pain in older emergency department patients.

    PubMed

    Chang, Andrew K; Bijur, Polly E; Davitt, Michelle; Gallagher, E John

    2013-09-01

    Opioid titration is an effective strategy for treating pain; however, titration is generally impractical in the busy emergency department (ED) setting. Our objective was to test a rapid, two-step, hydromorphone titration protocol against usual care in older patients presenting to the ED with acute severe pain. This was a prospective, randomized clinical trial of patients 65 years of age and older presenting to an adult, urban, academic ED with acute severe pain. The study was registered at http://www.clinicaltrials.gov (NCT01429285). Patients randomized to the hydromorphone titration protocol initially received 0.5 mg intravenous hydromorphone. Patients randomized to usual care received any dose of any intravenous opioid. At 15 min, patients in both groups were asked, 'Do you want more pain medication?' Patients in the hydromorphone titration group who answered 'yes' received a second dose of 0.5 mg intravenous hydromorphone. Patients in the usual care group who answered 'yes' had their ED attending physician notified, who then could administer any (or no) additional medication. The primary efficacy outcome was satisfactory analgesia defined a priori as the patient declining additional analgesia at least once when asked at 15 or 60 min after administration of the initial opioid. Dose was calculated in morphine equivalent units (MEU: 1 mg hydromorphone = 7 mg morphine). The need for naloxone to reverse adverse opioid effects was the primary safety outcome. 83.0 % of 153 patients in the hydromorphone titration group achieved satisfactory analgesia compared with 82.5 % of 166 patients in the usual care group (p = 0.91). Patients in the hydromorphone titration group received lower mean initial doses of opioids at baseline than patients in the usual care group (3.5 MEU vs. 4.7 MEU, respectively; p ≤ 0.001) and lower total opioids through 60 min (5.3 MEU vs. 6.0 MEU; p = 0.03). No patient needed naloxone. Low-dose titration of intravenous hydromorphone in increments of

  1. Overall Survival Analysis From a Randomized Phase II Study of Axitinib With or Without Dose Titration in First-Line Metastatic Renal Cell Carcinoma.

    PubMed

    Rini, Brian I; Tomita, Yoshihiko; Melichar, Bohuslav; Ueda, Takeshi; Grünwald, Viktor; Fishman, Mayer N; Uemura, Hirotsugu; Oya, Mototsugu; Bair, Angel H; Andrews, Glen I; Rosbrook, Brad; Jonasch, Eric

    2016-12-01

    In a randomized phase II trial in metastatic renal cell carcinoma (mRCC), objective response rate was significantly higher with axitinib versus placebo titration (54% vs. 34%; 1-sided P = .019). Treatment-naive patients with mRCC (n = 213) received axitinib 5 mg twice per day (b.i.d.) for 4 weeks. Patients meeting dose titration criteria were randomized to receive axitinib 5 mg b.i.d. with axitinib or placebo titration (n = 56 each); 91 patients ineligible for randomization continued axitinib 5 mg b.i.d.; 10 discontinued before randomization. Median overall survival (95% confidence interval [CI]) was 42.7 months (24.7-not estimable) with axitinib titration versus 30.4 months (23.7-45.0) with placebo titration (stratified hazard ratio, 0.785; 95% CI, 0.485-1.272; 1-sided P = .162), and 41.6 months (95% CI, 33.0-not estimable) in nonrandomized patients. Safety data were consistent with previous reports. Median overall survival was numerically longer in patients with first-line mRCC who received axitinib versus placebo titration. No new safety signal was observed after long-term axitinib treatment in first-line mRCC. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Non-damaging laser therapy of the macula: Titration algorithm and tissue response

    NASA Astrophysics Data System (ADS)

    Palanker, Daniel; Lavinsky, Daniel; Dalal, Roopa; Huie, Philip

    2014-02-01

    Retinal photocoagulation typically results in permanent scarring and scotomata, which limit its applicability to the macula, preclude treatments in the fovea, and restrict the retreatments. Non-damaging approaches to laser therapy have been tested in the past, but the lack of reliable titration and slow treatment paradigms limited their clinical use. We developed and tested a titration algorithm for sub-visible and non-damaging treatments of the retina with pulses sufficiently short to be used with pattern laser scanning. The algorithm based on Arrhenius model of tissue damage optimizes the power and duration for every energy level, relative to the threshold of lesion visibility established during titration (and defined as 100%). Experiments with pigmented rabbits established that lesions in the 50-75% energy range were invisible ophthalmoscopically, but detectable with Fluorescein Angiography and OCT, while at 30% energy there was only very minor damage to the RPE, which recovered within a few days. Patients with Diabetic Macular Edema (DME) and Central Serous Retinopathy (CSR) have been treated over the edematous areas at 30% energy, using 200μm spots with 0.25 diameter spacing. No signs of laser damage have been detected with any imaging modality. In CSR patients, subretinal fluid resolved within 45 days. In DME patients the edema decreased by approximately 150μm over 60 days. After 3-4 months some patients presented with recurrence of edema, and they responded well to retreatment with the same parameters, without any clinically visible damage. This pilot data indicates a possibility of effective and repeatable macular laser therapy below the tissue damage threshold.

  3. Microencapsulation of β-Carotene Based on Casein/Guar Gum Blend Using Zeta Potential-Yield Stress Phenomenon: an Approach to Enhance Photo-stability and Retention of Functionality.

    PubMed

    Thakur, Deepika; Jain, Ashay; Ghoshal, Gargi; Shivhare, U S; Katare, O P

    2017-07-01

    β-Carotene, abundant majorly in carrot, pink guava yams, spinach, kale, sweet potato, and palm oil, is an important nutrient for human health due to its scavenging action upon reactive free radicals wherever produced in the body. Inclusion of liposoluble β-carotene in foods and food ingredients is a challenging aspect due to its labile nature and low absorption from natural sources. This fact has led to the application of encapsulation of β-carotene to improve stability and bioavailability. The present work was aimed to fabricate microcapsules (MCs) of β-carotene oily dispersion using the complex coacervation technique with casein (CA) and guar gum (GG) blend. The ratio of CA:GG was found to be 1:0.5 (w/v) when optimized on the basis of zeta potential-yield stress phenomenon. These possessed a higher percentage yield (71.34 ± 0.55%), lower particle size (176.47 ± 4.65 μm), higher encapsulation efficiency (65.95 ± 5.33%), and in general, a uniform surface morphology was observed with particles showing optimized release behavior. Prepared MCs manifested effective and controlled release (up to 98%) following zero-order kinetics which was adequately explained by the Korseymer-Peppas model. The stability of the freeze-dried MCs was established in simulated gastrointestinal fluids (SGF, SIF) for 8 h. Antioxidant activity of the MCs was studied and revealed the retention of the functional architecture of β-carotene in freeze-dried MCs. Minimal photolytic degradation upon encapsulation of β-carotene addressed the challenge regarding photo-stability of β-carotene as confirmed via mass spectroscopy.

  4. On the theory of thermometric titration.

    PubMed

    Piloyan, G O; Dolinina, Y V

    1974-09-01

    The general equation defining the change in solution temperature DeltaT during a thermometric titration is DeltaT = T - T(0) = - AV 1 + BV where A and B are constants, V is the volume of titrant used to produce temperature T, and T(0) is the initial temperature. There is a linear relation between the inverse values of DeltaT and V: 1 Delta T = - a V - b where a = 1/A and b = B/A, both a and b being constants. A linear relation between DeltaT and V is usually a special case of this general relation, and is valid only over a narrow range of V. Graphs of 1/DeltaTvs. 1/V are more suitable for practical calculations than the usual graphs of DeltaTvs. V.

  5. Molecular Dynamics Simulation of the Titration of Polyoxocations in Aqueous Solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rustad, James R.

    The aqueous complex ion Al30O8(OH)56(H2O)26 18+(Al30) has a variety of bridging and terminal amphoteric surface functional groups which deprotonate over a pH range of 4–7. Their relative degree of protonation is calculated here from a series of molecular dynamics simulations in what appear to be the first molecular dynamics simulations of an acidometric titration. In these simulations, a model M30O8(OH)56(H2O)26 18+ ion is embedded in aqueous solution and titrated with hydroxide ions in the presence of a charge-compensating background of perchlorate ions. Comparison with titration of a model M13O4(OH)24(H2O)12 7+ reveals that the M30 ion is more acidic than themore » M13 ion due to the presence of acidic nH2O functional groups. The higher acidities of the functional groups on the M30 ion appear to result from enhanced hydration. Metal–oxygen bond lengths are calculated for the ion in solution, an isolated ion in the gas phase, and in its crystalline hydrate sulfate salt. Gas-phase and crystalline bond lengths do not correlate well with those calculated in solution. The acidities do not relate in any simple way to the number of metals coordinating the surface functional group or the M-O bond length. Moreover, the calculated acidity in solution does not correlate with proton affinities calculated for the isolated ion in the absence of solvent. It is concluded that the search for simple indicators of structure–reactivity relationships at the level of individual reactive sites faces major limitations, unless specific information on the hydration states of the functional groups is available.« less

  6. Titration of biologically active amyloid–β seeds in a transgenic mouse model of Alzheimer's disease

    PubMed Central

    Morales, Rodrigo; Bravo-Alegria, Javiera; Duran-Aniotz, Claudia; Soto, Claudio

    2015-01-01

    Experimental evidence in animal models suggests that misfolded Amyloid-β (Aβ) spreads in disease following a prion-like mechanism. Several properties characteristics of infectious prions have been shown for the induction of Aβ aggregates. However, a detailed titration of Aβ misfolding transmissibility and estimation of the minimum concentration of biologically active Aβ seeds able to accelerate pathological changes has not yet been performed. In this study, brain extracts from old tg2576 animals were serially diluted and intra-cerebrally injected into young subjects from the same transgenic line. Animals were sacrificed several months after treatment and brain slices were analyzed for amyloid pathology. We observed that administration of misfolded Aβ was able to significantly accelerate amyloid deposition in young mice, even when the original sample was diluted a million times. The titration curve obtained in this experiment was compared to the natural Aβ load spontaneously accumulated by these mice overtime. Our findings suggest that administration of the largest dose of Aβ seeds led to an acceleration of pathology equivalent to over a year. These results show that active Aβ seeds present in the brain can seed amyloidosis in a titratable manner, similarly as observed for infectious prions. PMID:25879692

  7. Flow cytometry for enrichment and titration in massively parallel DNA sequencing

    PubMed Central

    Sandberg, Julia; Ståhl, Patrik L.; Ahmadian, Afshin; Bjursell, Magnus K.; Lundeberg, Joakim

    2009-01-01

    Massively parallel DNA sequencing is revolutionizing genomics research throughout the life sciences. However, the reagent costs and labor requirements in current sequencing protocols are still substantial, although improvements are continuously being made. Here, we demonstrate an effective alternative to existing sample titration protocols for the Roche/454 system using Fluorescence Activated Cell Sorting (FACS) technology to determine the optimal DNA-to-bead ratio prior to large-scale sequencing. Our method, which eliminates the need for the costly pilot sequencing of samples during titration is capable of rapidly providing accurate DNA-to-bead ratios that are not biased by the quantification and sedimentation steps included in current protocols. Moreover, we demonstrate that FACS sorting can be readily used to highly enrich fractions of beads carrying template DNA, with near total elimination of empty beads and no downstream sacrifice of DNA sequencing quality. Automated enrichment by FACS is a simple approach to obtain pure samples for bead-based sequencing systems, and offers an efficient, low-cost alternative to current enrichment protocols. PMID:19304748

  8. Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

    PubMed

    Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming

    2013-04-01

    Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P < 0.001) in 51 patients. The cohort study of 100 patients showed that AHI was satisfactorily decreased after CPAP treatment using a pressure derived from manual titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P < 0.001). The results suggest that automatic titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  9. Competitive counterion complexation allows the true host : guest binding constants from a single titration by ionic receptors.

    PubMed

    Pessêgo, Márcia; Basílio, Nuno; Muñiz, M Carmen; García-Río, Luis

    2016-07-06

    Counterion competitive complexation is a background process currently ignored by using ionic hosts. Consequently, guest binding constants are strongly affected by the design of the titration experiments in such a way that the results are dependent on the guest concentration and on the presence of added salts, usually buffers. In the present manuscript we show that these experimental difficulties can be overcome by just considering the counterion competitive complexation. Moreover a single titration allows us to obtain not only the true binding constants but also the stoichiometry of the complex showing the formation of 1 : 1 : 1 (host : guest : counterion) complexes. The detection of high stoichiometry complexes is not restricted to a single titration experiment but also to a displacement assay where both competitive and competitive-cooperative complexation models are taken into consideration.

  10. Effectiveness of a management program for outpatient clinic or remote titration of beta-blockers in CRT patients: The RESTORE study.

    PubMed

    D'Onofrio, Antonio; Palmisano, Pietro; Rapacciuolo, Antonio; Ammendola, Ernesto; Calò, Leonardo; Ruocco, Antonio; Bianchi, Valter; Maresca, Fabio; Del Giorno, Giuseppe; Martino, Annamaria; Mauro, Ciro; Campari, Monica; Valsecchi, Sergio; Accogli, Michele

    2017-06-01

    Many patients fail to receive β-blockers before cardiac resynchronization therapy defibrillator (CRT-D) implantation, or receive them at a suboptimal dose, and require optimization after implantation. We assessed the effectiveness of a structured program for β-blocker titration in CRT-D patients followed up by means of conventional in-clinic visits or remote monitoring. 130 patients undergoing CRT implantation and treated according to the standard practice of the centers were included as a control group. A second group of 124 CRT-D candidates (Study Group) underwent up-titration visits every 2weeks after implantation (target dose: 10mg/day of bisoprolol or 50mg/day of carvedilol). In the Study Group, remote monitoring was undertaken in 66 patients, who received additional equipment for daily transmission of weight and blood pressure data, and scheduled titration telephone calls. In the Control Group, the maximal dose of β-blockers was being administered to 12 (9%) patients on implantation and 21 (16%) on 6-month follow-up examination (p>0.05). In the Study Group, 25 (20%) patients were receiving the maximal dose of β-blockers on implantation and 72 (58%) on follow-up examination (p<0.001). The 66 Study Group patients on remote monitoring underwent fewer in-clinic visits (p=0.034). Of these, 50 (76%) were on the maximal dose after remote up-titration (versus 38% of patients followed up conventionally, p<0.001). The decrease in left ventricular end-systolic volume was larger in the Study Group (p=0.040). The program for β-blocker up-titration increased the number of patients reaching the target dose and improved the response to the therapy. The use of remote monitoring and daily transfer of weight and blood pressure data facilitated β-blocker titration. URL: http://clinicaltrials.gov/ Identifier: NCT02173028. Copyright © 2017. Published by Elsevier B.V.

  11. Dose Titration of Pregabalin in Patients with Painful Diabetic Peripheral Neuropathy: Simulation Based on Observational Study Patients Enriched with Data from Randomized Studies.

    PubMed

    Alexander, Joe; Edwards, Roger A; Manca, Luigi; Grugni, Roberto; Bonfanti, Gianluca; Emir, Birol; Whalen, Edward; Watt, Stephen; Parsons, Bruce

    2018-03-01

    Achieving a therapeutic response to pregabalin in patients with painful diabetic peripheral neuropathy (pDPN) requires adequate upward dose titration. Our goal was to identify relationships between titration and response to pregabalin in patients with pDPN. Data were integrated from nine randomized, placebo-controlled clinical trials as well as one 6-week open-label observational study conducted by 5808 physicians (2642 patients with pDPN) in standard outpatient settings in Germany. These studies evaluated pregabalin for treatment of pDPN. Using these data, we examined "what if" scenarios using a microsimulation platform that integrates data from randomized and observational sources as well as autoregressive-moving-average with exogenous inputs models that predict pain outcomes, taking into account weekly changes in pain, sleep interference, dose, and other patient characteristics that were unchanging. Final pain levels were significantly different depending on dose changes (P < 0.0001), with greater proportions improving with upward titration regardless of baseline pain severity. Altogether, 78.5% of patients with pDPN had 0-1 dose change, and 15.2% had ≥ 2 dose changes. Simulation demonstrated that the 4.8% of inadequately titrated patients who did not improve/very much improve their pain levels would have benefited from ≥ 2 dose changes. Patient satisfaction with tolerability (range 90.3-96.2%) was similar, regardless of baseline pain severity, number of titrations, or extent of improvement, suggesting that tolerability did not influence treatment response patterns. Upward dose titration reduced pain in patients with pDPN who actually received it. Simulation also predicted pain reduction in an inadequately titrated nonresponder subgroup of patients had they actually received adequate titration. The decision not to uptitrate must have been driven by factors other than tolerability. Pfizer, Inc.

  12. Moments of zeta functions associated to hyperelliptic curves over finite fields

    PubMed Central

    Rubinstein, Michael O.; Wu, Kaiyu

    2015-01-01

    Let q be an odd prime power, and denote the set of square-free monic polynomials D(x)∈Fq[x] of degree d. Katz and Sarnak showed that the moments, over , of the zeta functions associated to the curves y2=D(x), evaluated at the central point, tend, as , to the moments of characteristic polynomials, evaluated at the central point, of matrices in USp(2⌊(d−1)/2⌋). Using techniques that were originally developed for studying moments of L-functions over number fields, Andrade and Keating conjectured an asymptotic formula for the moments for q fixed and . We provide theoretical and numerical evidence in favour of their conjecture. In some cases, we are able to work out exact formulae for the moments and use these to precisely determine the size of the remainder term in the predicted moments. PMID:25802418

  13. Automated spectrophotometric bicarbonate analysis in duodenal juice compared to the back titration method.

    PubMed

    Erchinger, Friedemann; Engjom, Trond; Gudbrandsen, Oddrun Anita; Tjora, Erling; Gilja, Odd H; Dimcevski, Georg

    2016-01-01

    We have recently evaluated a short endoscopic secretin test for exocrine pancreatic function. Bicarbonate concentration in duodenal juice is an important parameter in this test. Measurement of bicarbonate by back titration as the gold standard method is time consuming, expensive and technically difficult, thus a simplified method is warranted. We aimed to evaluate an automated spectrophotometric method in samples spanning the effective range of bicarbonate concentrations in duodenal juice. We also evaluated if freezing of samples before analyses would affect its results. Patients routinely examined with short endoscopic secretin test suspected to have decreased pancreatic function of various reasons were included. Bicarbonate in duodenal juice was quantified by back titration and automatic spectrophotometry. Both fresh and thawed samples were analysed spectrophotometrically. 177 samples from 71 patients were analysed. Correlation coefficient of all measurements was r = 0.98 (p < 0.001). Correlation coefficient of fresh versus frozen samples conducted with automatic spectrophotometry (n = 25): r = 0.96 (p < 0.001) CONCLUSIONS: The measurement of bicarbonate in fresh and thawed samples by automatic spectrophotometrical analysis correlates excellent with the back titration gold standard. This is a major simplification of direct pancreas function testing, and allows a wider distribution of bicarbonate testing in duodenal juice. Extreme values for Bicarbonate concentration achieved by the autoanalyser method have to be interpreted with caution. Copyright © 2016 IAP and EPC. Published by Elsevier India Pvt Ltd. All rights reserved.

  14. Insulin degludec/insulin aspart once daily in Type 2 diabetes: a comparison of simple or stepwise titration algorithms (BOOST® : SIMPLE USE).

    PubMed

    Park, S W; Bebakar, W M W; Hernandez, P G; Macura, S; Hersløv, M L; de la Rosa, R

    2017-02-01

    To compare the efficacy and safety of two titration algorithms for insulin degludec/insulin aspart (IDegAsp) administered once daily with metformin in participants with insulin-naïve Type 2 diabetes mellitus. This open-label, parallel-group, 26-week, multicentre, treat-to-target trial, randomly allocated participants (1:1) to two titration arms. The Simple algorithm titrated IDegAsp twice weekly based on a single pre-breakfast self-monitored plasma glucose (SMPG) measurement. The Stepwise algorithm titrated IDegAsp once weekly based on the lowest of three consecutive pre-breakfast SMPG measurements. In both groups, IDegAsp once daily was titrated to pre-breakfast plasma glucose values of 4.0-5.0 mmol/l. Primary endpoint was change from baseline in HbA 1c (%) after 26 weeks. Change in HbA 1c at Week 26 was IDegAsp Simple -14.6 mmol/mol (-1.3%) (to 52.4 mmol/mol; 6.9%) and IDegAsp Stepwise -11.9 mmol/mol (-1.1%) (to 54.7 mmol/mol; 7.2%). The estimated between-group treatment difference was -1.97 mmol/mol [95% confidence interval (CI) -4.1, 0.2] (-0.2%, 95% CI -0.4, 0.02), confirming the non-inferiority of IDegAsp Simple to IDegAsp Stepwise (non-inferiority limit of ≤ 0.4%). Mean reduction in fasting plasma glucose and 8-point SMPG profiles were similar between groups. Rates of confirmed hypoglycaemia were lower for IDegAsp Stepwise [2.1 per patient years of exposure (PYE)] vs. IDegAsp Simple (3.3 PYE) (estimated rate ratio IDegAsp Simple /IDegAsp Stepwise 1.8; 95% CI 1.1, 2.9). Nocturnal hypoglycaemia rates were similar between groups. No severe hypoglycaemic events were reported. In participants with insulin-naïve Type 2 diabetes mellitus, the IDegAsp Simple titration algorithm improved HbA 1c levels as effectively as a Stepwise titration algorithm. Hypoglycaemia rates were lower in the Stepwise arm. © 2016 The Authors. Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.

  15. Kinetic titration with differential thermometric determination of the end-point.

    PubMed

    Sajó, I

    1968-06-01

    A method has been described for the determination of concentrations below 10(-4)M by applying catalytic reactions and using thermometric end-point determination. A reference solution, identical with the sample solution except for catalyst, is titrated with catalyst solution until the rates of reaction become the same, as shown by a null deflection on a galvanometer connected via bridge circuits to two opposed thermistors placed in the solutions.

  16. Protein sequences and redox titrations indicate that the electron acceptors in reaction centers from heliobacteria are similar to Photosystem I

    NASA Technical Reports Server (NTRS)

    Trost, J. T.; Brune, D. C.; Blankenship, R. E.

    1992-01-01

    Photosynthetic reaction centers isolated from Heliobacillus mobilis exhibit a single major protein on SDS-PAGE of 47 000 Mr. Attempts to sequence the reaction center polypeptide indicated that the N-terminus is blocked. After enzymatic and chemical cleavage, four peptide fragments were sequenced from the Heliobacillus mobilis apoprotein. Only one of these sequences showed significant specific similarity to any of the protein and deduced protein sequences in the GenBank data base. This fragment is identical with 56% of the residues, including both cysteines, found in highly conserved region that is proposed to bind iron-sulfur center Fx in the Photosystem I reaction center peptide that is the psaB gene product. The similarity to the psaA gene product in this region is 48%. Redox titrations of laser-flash-induced photobleaching with millisecond decay kinetics on isolated reaction centers from Heliobacterium gestii indicate a midpoint potential of -414 mV with n = 2 titration behavior. In membranes, the behavior is intermediate between n = 1 and n = 2, and the apparent midpoint potential is -444 mV. This is compared to the behavior in Photosystem I, where the intermediate electron acceptor A1, thought to be a phylloquinone molecule, has been proposed to undergo a double reduction at low redox potentials in the presence of viologen redox mediators. These results strongly suggest that the acceptor side electron transfer system in reaction centers from heliobacteria is indeed analogous to that found in Photosystem I. The sequence similarities indicate that the divergence of the heliobacteria from the Photosystem I line occurred before the gene duplication and subsequent divergence that lead to the heterodimeric protein core of the Photosystem I reaction center.

  17. Energy Minimization of Discrete Protein Titration State Models Using Graph Theory.

    PubMed

    Purvine, Emilie; Monson, Kyle; Jurrus, Elizabeth; Star, Keith; Baker, Nathan A

    2016-08-25

    There are several applications in computational biophysics that require the optimization of discrete interacting states, for example, amino acid titration states, ligand oxidation states, or discrete rotamer angles. Such optimization can be very time-consuming as it scales exponentially in the number of sites to be optimized. In this paper, we describe a new polynomial time algorithm for optimization of discrete states in macromolecular systems. This algorithm was adapted from image processing and uses techniques from discrete mathematics and graph theory to restate the optimization problem in terms of "maximum flow-minimum cut" graph analysis. The interaction energy graph, a graph in which vertices (amino acids) and edges (interactions) are weighted with their respective energies, is transformed into a flow network in which the value of the minimum cut in the network equals the minimum free energy of the protein and the cut itself encodes the state that achieves the minimum free energy. Because of its deterministic nature and polynomial time performance, this algorithm has the potential to allow for the ionization state of larger proteins to be discovered.

  18. Energy Minimization of Discrete Protein Titration State Models Using Graph Theory

    PubMed Central

    Purvine, Emilie; Monson, Kyle; Jurrus, Elizabeth; Star, Keith; Baker, Nathan A.

    2016-01-01

    There are several applications in computational biophysics which require the optimization of discrete interacting states; e.g., amino acid titration states, ligand oxidation states, or discrete rotamer angles. Such optimization can be very time-consuming as it scales exponentially in the number of sites to be optimized. In this paper, we describe a new polynomial-time algorithm for optimization of discrete states in macromolecular systems. This algorithm was adapted from image processing and uses techniques from discrete mathematics and graph theory to restate the optimization problem in terms of “maximum flow-minimum cut” graph analysis. The interaction energy graph, a graph in which vertices (amino acids) and edges (interactions) are weighted with their respective energies, is transformed into a flow network in which the value of the minimum cut in the network equals the minimum free energy of the protein, and the cut itself encodes the state that achieves the minimum free energy. Because of its deterministic nature and polynomial-time performance, this algorithm has the potential to allow for the ionization state of larger proteins to be discovered. PMID:27089174

  19. Effect of dissolved oxygen on two bacterial pathogens examined using ATR-FTIR spectroscopy, microelectrophoresis, and potentiometric titration.

    PubMed

    Castro, Felipe D; Sedman, Jacqueline; Ismail, Ashraf A; Asadishad, Bahareh; Tufenkji, Nathalie

    2010-06-01

    The effects of dissolved oxygen tension during bacterial growth and acclimation on the cell surface properties and biochemical composition of the bacterial pathogens Escherichia coli O157:H7 and Yersinia enterocolitica are characterized. Three experimental techniques are used in an effort to understand the influence of bacterial growth and acclimation conditions on cell surface charge and the composition of the bacterial cell: (i) electrophoretic mobility measurements; (ii) potentiometric titration; and (iii) ATR-FTIR spectroscopy. Potentiometric titration data analyzed using chemical speciation software are related to measured electrophoretic mobilities at the pH of interest. Titration of bacterial cells is used to identify the major proton-active functional groups and the overall concentration of these cell surface ligands at the cell membrane. Analysis of titration data shows notable differences between strains and conditions, confirming the appropriateness of this tool for an overall charge characterization. ATR-FTIR spectroscopy of whole cells is used to further characterize the bacterial biochemical composition and macromolecular structures that might be involved in the development of the net surficial charge of the organisms examined. The evaluation of the integrated intensities of HPO(2)(-) and carbohydrate absorption bands in the IR spectra reveals clear differences between growth protocols. Taken together, the three techniques seem to indicate that the dissolved oxygen tension during cell growth or acclimation can noticeably influence the expression of cell surface molecules and the measurable cell surface charge, though in a strain-dependent fashion.

  20. Pilot study of a new device to titrate oxygen flow in hypoxic patients on long-term oxygen therapy.

    PubMed

    Cirio, Serena; Nava, Stefano

    2011-04-01

    The O(2) Flow Regulator (Dima, Bologna, Italy) is a new automated oxygen regulator that titrates the oxygen flow based on a pulse-oximetry signal to maintain a target S(pO(2)). We tested the device's safety and efficacy. We enrolled 18 subjects with chronic lung disease, exercise-induced desaturation, and on long-term oxygen therapy, in a randomized crossover study with 2 constant-work-load 15-min cycling exercise tests, starting with the patient's previously prescribed usual oxygen flow. In one test the oxygen flow was titrated manually by the respiratory therapist, and in the other test the oxygen flow was titrated by the O(2) Flow Regulator, to maintain an S(pO(2)) of 94%. We measured S(pO(2)) throughout each test, the time spent by the respiratory therapist to set the device or to manually regulate the oxygen flow, and the total number of respiratory-therapist titration interventions during the trial. There were no differences in symptoms or heart rate between the exercise tests. Compared to the respiratory-therapist-controlled tests, during the O(2) Flow Regulator tests S(pO(2)) was significantly higher (95 ± 2% vs 93 ± 3%, P = .04), significantly less time was spent below the target S(pO(2)) (171 ± 187 s vs 340 ± 220 s, P < .001), and the O(2) Flow Regulator tests required significantly less respiratory therapist time (5.6 ± 3.7 min vs 2.0 ± 0.1 min, P = .005). The O(2) Flow Regulator may be a safe and effective alternative to manual oxygen titration during exercise in hypoxic patients. It provided stable S(pO(2)) and avoided desaturations in our subjects.

  1. [Dose-finding for treatment with a transdermal fentanyl patch : Titration with oral transmucosal fentanyl citrate and morphine sulfate].

    PubMed

    Mücke, M; Conrad, R; Marinova, M; Cuhls, H; Elsner, F; Rolke, R; Radbruch, L

    2016-12-01

    To date, no studies investigating titration with oral transmucosal fentanyl for the dose-finding of transdermal fentanyl treatment have been published. In an open randomized study 60 patients with chronic malignant (n = 39) or nonmalignant pain (n = 21), who required opioid therapy according to step three of the guidelines of the World Health Organization (WHO), were investigated. In two groups of 30 patients each titration with immediate release morphine (IRM) or oral transmucosal fentanyl citrate (OTFC) was undertaken. For measurement purposes the Brief Pain Inventory (BPI) and Minimal Documentation System (MIDOS) were used. After a 24-h titration phase, in which patients documented the intensity of pain, nausea, and tiredness, treatment with transdermal fentanyl was evaluated over a 10-day period by means of the necessary dose adaptation (responder ≤ 1 dose adaptation; conversion formula 1:1 [OTFC group] vs 100:1 [IRM group]).The pain reduction over the first 24 h (titration phase) did not differ significantly between the groups. The number of responders (17 OTFC vs. 21 IRM) over the 10-day period did not show any difference either. In both groups there was a significant reduction in pain intensity (p < 0.001). Over the course of the study, there were significantly more drop-outs because of adverse effects in the OTFC group than in the IRM group (8 vs 1, p = 0.028).Oral transmucosal fentanyl citrate can be applied for the titration of transdermal fentanyl, but it does not show any clinically relevant advantage. For example, the risk of side effects-induced drop-outs was greater in the present study. Whether the unnecessary opioid switching to treat chronic pain and breakthrough pain is advantageous with regard to minimizing conversion errors cannot be definitively answered within the scope of this study.

  2. Effect of temperature on the acid-base properties of the alumina surface: microcalorimetry and acid-base titration experiments.

    PubMed

    Morel, Jean-Pierre; Marmier, Nicolas; Hurel, Charlotte; Morel-Desrosiers, Nicole

    2006-06-15

    Sorption reactions on natural or synthetic materials that can attenuate the migration of pollutants in the geosphere could be affected by temperature variations. Nevertheless, most of the theoretical models describing sorption reactions are at 25 degrees C. To check these models at different temperatures, experimental data such as the enthalpies of sorption are thus required. Highly sensitive microcalorimeters can now be used to determine the heat effects accompanying the sorption of radionuclides on oxide-water interfaces, but enthalpies of sorption cannot be extracted from microcalorimetric data without a clear knowledge of the thermodynamics of protonation and deprotonation of the oxide surface. However, the values reported in the literature show large discrepancies and one must conclude that, amazingly, this fundamental problem of proton binding is not yet resolved. We have thus undertaken to measure by titration microcalorimetry the heat effects accompanying proton exchange at the alumina-water interface at 25 degrees C. Based on (i) the surface sites speciation provided by a surface complexation model (built from acid-base titrations at 25 degrees C) and (ii) results of the microcalorimetric experiments, calculations have been made to extract the enthalpic variations associated respectively to first and second deprotonation of the alumina surface. Values obtained are deltaH1 = 80+/-10 kJ mol(-1) and deltaH2 = 5+/-3 kJ mol(-1). In a second step, these enthalpy values were used to calculate the alumina surface acidity constants at 50 degrees C via the van't Hoff equation. Then a theoretical titration curve at 50 degrees C was calculated and compared to the experimental alumina surface titration curve. Good agreement between the predicted acid-base titration curve and the experimental one was observed.

  3. Thermodynamic investigation of the binding of dissymmetric pyrenyl-gemini surfactants to DNA.

    PubMed

    Wettig, Shawn D; Deubry, Rubena; Akbar, Javed; Kaur, Tranum; Wang, Haitang; Sheinin, Tatiana; Joseph, Jamie W; Slavcev, Roderick A

    2010-05-14

    Gemini surfactants have demonstrated significant potential for use in constructing non-viral transfection vectors for the delivery of genes into cells to induce protein expression. Previously, two asymmetric gemini surfactants containing pyrenyl groups in one of the alkyl tails of the surfactants were synthesized as fluorescence probes for use in mechanistic studies of the transfection process. Here we present the results of a thermodynamic investigation of the binding interaction(s) between the pyrenyl-modified surfactants and DNA. The thermodynamics of the interactions have been examined using isothermal titration calorimetry, light scattering, zeta potential, and circular dichroism measurements. Distinct differences are observed between the interaction of 12-s-12 vs. the pyrene modified py-s-12 surfactants with DNA; an intercalated binding is found for the py-s-12 surfactants that disrupts the typical interactions observed between DNA and gemini surfactants.

  4. Binding of copper to lysozyme: Spectroscopic, isothermal titration calorimetry and molecular docking studies

    NASA Astrophysics Data System (ADS)

    Jing, Mingyang; Song, Wei; Liu, Rutao

    2016-07-01

    Although copper is essential to all living organisms, its potential toxicity to human health have aroused wide concerns. Previous studies have reported copper could alter physical properties of lysozyme. The direct binding of copper with lysozyme might induce the conformational and functional changes of lysozyme and then influence the body's resistance to bacterial attack. To better understand the potential toxicity and toxic mechanisms of copper, the interaction of copper with lysozyme was investigated by biophysical methods including multi-spectroscopic measurements, isothermal titration calorimetry (ITC), molecular docking study and enzyme activity assay. Multi-spectroscopic measurements proved that copper quenched the intrinsic fluorescence of lysozyme in a static process accompanied by complex formation and conformational changes. The ITC results indicated that the binding interaction was a spontaneous process with approximately three thermodynamical binding sites at 298 K and the hydrophobic force is the predominant driven force. The enzyme activity was obviously inhibited by the addition of copper with catalytic residues Glu 35 and Asp 52 locating at the binding sites. This study helps to elucidate the molecular mechanism of the interaction between copper and lysozyme and provides reference for toxicological studies of copper.

  5. Calorimetry, activity, and micro-FTIR analysis of CO chemisorption, titration, and oxidation on supported Pt

    NASA Technical Reports Server (NTRS)

    Sermon, Paul A.; Self, Valerie A.; Vong, Mariana S. W.; Wurie, Alpha T.

    1990-01-01

    The value of in situ analysis on CO chemisorption, titration and oxidation over supported Pt catalysts using calorimetry, catalytic and micro-FTIR methods is illustrated using silica- and titania-supported samples. Isothermal CO-O and O2-CO titrations have not been widely used on metal surfaces and may be complicated if some oxide supports are reduced by CO titrant. However, they can illuminate the kinetics of CO oxidation on metal/oxide catalysts since during such titrations all O and CO coverages are scanned as a function of time. There are clear advantages in following the rates of the catalyzed CO oxidation via calorimetry and gc-ms simultaneously. At lower temperatures the evidence they provide is complementary. CO oxidation and its catalysis of CO oxidation have been extensively studied with hysteresis and oscillations apparent, and the present results suggest the benefits of a combined approach. Silica support porosity may be important in defining activity-temperature hysteresis. FTIR microspectroscopy reveals the chemical heterogeneity of the catalytic surfaces used; it is interesting that the evidence with regard to the dominant CO surface species and their reactivities with regard to surface oxygen for present oxide-supported Pt are different from those seen on graphite-supported Pt.

  6. Streaming potential method for characterizing interaction of electrical double layers between rice roots and Fe/Al oxide-coated quartz in situ.

    PubMed

    Liu, Zhao-Dong; Wang, Hai-Cui; Li, Jiu-Yu; Xu, Ren-Kou

    2017-10-01

    The interaction between rice roots and Fe/Al oxide-coated quartz was investigated through zeta potential measurements and column leaching experiments in present study. The zeta potentials of rice roots, Fe/Al oxide-coated quartz, and the binary systems containing rice roots and Fe/Al oxide-coated quartz were measured by a specially constructed streaming potential apparatus. The interactions between rice roots and Fe/Al oxide-coated quartz particles were evaluated/deduced based on the differences of zeta potentials between the binary systems and the single system of rice roots. The zeta potentials of the binary systems moved in positive directions compared with that of rice roots, suggesting that there were overlapping of diffuse layers of electric double layers on positively charged Fe/Al oxide-coated quartz and negatively charged rice roots and neutralization of positive charge on Fe/Al oxide-coated quartz with negative charge on rice roots. The greater amount of positive charges on Al oxide led to the stronger interaction of Al oxide-coated quartz with rice roots and the more shift of zeta potential compared with Fe oxide. The overlapping of diffuse layers on Fe/Al oxide-coated quartz and rice roots was confirmed by column leaching experiments. The greater overlapping of diffuse layers on Al oxide and rice roots led to more simultaneous adsorptions of K + and NO 3 - and greater reduction in leachate electric conductivity when the column containing Al oxide-coated quartz and rice roots was leached with KNO 3 solution, compared with the columns containing rice roots and Fe oxide-coated quartz or quartz. When the KNO 3 solution was replaced with deionized water to flush the columns, more K + and NO 3 - were desorbed from the binary system containing Al oxide-coated quartz and rice roots than from other two binary systems, suggesting that the stronger electrostatic interaction between Al oxide and rice roots promoted the desorption of K + and NO 3 - from the binary

  7. Tc Trends and Terrestrial Planet Formation: The Case of Zeta Reticuli

    NASA Astrophysics Data System (ADS)

    Adibekyan, Vardan; Delgado-Mena, Elisa; Figueira, Pedro; Sousa, Sergio; Santos, Nuno; Faria, Joao; González Hernández, Jonay; Israelian, Garik; Harutyunyan, Gohar; Suárez-Andrés, Lucia; Hakobyan, Artur

    2016-11-01

    During the last decade astronomers have been trying to search for chemical signatures of terrestrial planet formation in the atmospheres of the hosting stars. Several studies suggested that the chemical abundance trend with the condensation temperature, Tc, is a signature of rocky planet formation. In particular, it was suggested that the Sun shows 'peculiar' chemical abundances due to the presence of the terrestrial planets in our solar-system. However, the rocky material accretion or the trap of rocky materials in terrestrial planets is not the only explanation for the chemical 'peculiarity' of the Sun, or other Sun-like stars with planets. In this talk I madea very brief review of this topic, and presented our last results for the particular case of Zeta Reticuli binary system: A very interesting and well-known system (known in science fiction and ufology as the world of Grey Aliens, or Reticulans) where one of the components hosts an exo-Kuiper belt, and the other component is a 'single', 'lonely' star.

  8. High temperature microelectrophoresis studies of the solid oxide/water interface

    NASA Astrophysics Data System (ADS)

    Fedkin, Mark Valentinovich

    Metal oxides are abundant components of geo-environmental systems and are widely used materials in industry. Many practical applications of oxide materials require the knowledge of their surface properties at both ambient and elevated temperatures. Due to substantial technical challenges associated with experimental studies of solid/water interfaces at elevated temperatures, consistent data on adsorption, surface charge, and zeta potential for most oxide materials are limited to temperatures less than 100°C. A high temperature microelectrophoresis technique, developed in this study, made it possible to extend the zeta potential measurements at the solid oxide/water interface to 200°C. The design of the high temperature electrophoresis cell allowed for the visual microscopic observation of the electrophoretic movement of suspended particles through pressure-tight sapphire windows. The electrophoretic mobilities of metal oxide particles suspended in aqueous solutions were measured in a DC electric field as a function of pH, ionic strength, and temperature. The experimental procedure and methods for evaluation of the main experimental parameters (electrophoretic mobility, electric field strength, high temperature pH, and cell constant) have been developed. Zeta potentials were calculated from the experimental data using O'Brien and White's (1978) numerical solution for electrophoretic mobility equation. Zeta potentials and isoelectric points (IEP) of the metal oxide/aqueous solution interface were experimentally determined for ZrO2, TiO 2(rutile), and alphaAl2O3 at 25, 120, and 200°C. The background solutions used for the preparation of suspensions were pure H2O, NaCl(aq) (10-4--10-2 mol.kg-1), and SrCl2 (10-4 mol.kg, for TiO2). For all studied materials, the IEPs were found to regularly decrease with increasing temperature, which agrees with available theoretical predictions. Thermodynamic functions, including Gibbs energy, enthalpy, and heat capacity, were

  9. Novel approaches to analysis by flow injection gradient titration.

    PubMed

    Wójtowicz, Marzena; Kozak, Joanna; Kościelniak, Paweł

    2007-09-26

    Two novel procedures for flow injection gradient titration with the use of a single stock standard solution are proposed. In the multi-point single-line (MP-SL) method the calibration graph is constructed on the basis of a set of standard solutions, which are generated in a standard reservoir and subsequently injected into the titrant. According to the single-point multi-line (SP-ML) procedure the standard solution and a sample are injected into the titrant stream from four loops of different capacities, hence four calibration graphs are able to be constructed and the analytical result is calculated on the basis of a generalized slope of these graphs. Both approaches have been tested on the example of spectrophotometric acid-base titration of hydrochloric and acetic acids with using bromothymol blue and phenolphthalein as indicators, respectively, and sodium hydroxide as a titrant. Under optimized experimental conditions the analytical results of precision less than 1.8 and 2.5% (RSD) and of accuracy less than 3.0 and 5.4% (relative error (RE)) were obtained for MP-SL and SP-ML procedures, respectively, in ranges of 0.0031-0.0631 mol L(-1) for samples of hydrochloric acid and of 0.1680-1.7600 mol L(-1) for samples of acetic acid. The feasibility of both methods was illustrated by applying them to the total acidity determination in vinegar samples with precision lower than 0.5 and 2.9% (RSD) for MP-SL and SP-ML procedures, respectively.

  10. A Geochemical Reaction Model for Titration of Contaminated Soil and Groundwater at the Oak Ridge Reservation

    NASA Astrophysics Data System (ADS)

    Zhang, F.; Parker, J. C.; Gu, B.; Luo, W.; Brooks, S. C.; Spalding, B. P.; Jardine, P. M.; Watson, D. B.

    2007-12-01

    This study investigates geochemical reactions during titration of contaminated soil and groundwater at the Oak Ridge Reservation in eastern Tennessee. The soils and groundwater exhibits low pH and high concentrations of aluminum, calcium, magnesium, manganese, various trace metals such as nickel and cobalt, and radionuclides such as uranium and technetium. The mobility of many of the contaminant species diminishes with increasing pH. However, base additions to increase pH are strongly buffered by various precipitation/dissolution and adsorption/desorption reactions. The ability to predict acid-base behavior and associated geochemical effects is thus critical to evaluate remediation performance of pH manipulation strategies. This study was undertaken to develop a practical but generally applicable geochemical model to predict aqueous and solid-phase speciation during soil and groundwater titration. To model titration in the presence of aquifer solids, an approach proposed by Spalding and Spalding (2001) was utilized, which treats aquifer solids as a polyprotic acid. Previous studies have shown that Fe and Al-oxyhydroxides strongly sorb dissolved Ni, U and Tc species. In this study, since the total Fe concentration is much smaller than that of Al, only ion exchange reactions associated with Al hydroxides are considered. An equilibrium reaction model that includes aqueous complexation, precipitation, ion exchange, and soil buffering reactions was developed and implemented in the code HydroGeoChem 5.0 (HGC5). Comparison of model results with experimental titration curves for contaminated groundwater alone and for soil- water systems indicated close agreement. This study is expected to facilitate field-scale modeling of geochemical processes under conditions with highly variable pH to develop practical methods to control contaminant mobility at geochemically complex sites.

  11. Polyelectrolyte assisted charge titration spectrometry: Applications to latex and oxide nanoparticles.

    PubMed

    Mousseau, F; Vitorazi, L; Herrmann, L; Mornet, S; Berret, J-F

    2016-08-01

    The electrostatic charge density of particles is of paramount importance for the control of the dispersion stability. Conventional methods use potentiometric, conductometric or turbidity titration but require large amount of samples. Here we report a simple and cost-effective method called polyelectrolyte assisted charge titration spectrometry or PACTS. The technique takes advantage of the propensity of oppositely charged polymers and particles to assemble upon mixing, leading to aggregation or phase separation. The mixed dispersions exhibit a maximum in light scattering as a function of the volumetric ratio X, and the peak position XMax is linked to the particle charge density according to σ∼D0XMax where D0 is the particle diameter. The PACTS is successfully applied to organic latex, aluminum and silicon oxide particles of positive or negative charge using poly(diallyldimethylammonium chloride) and poly(sodium 4-styrenesulfonate). The protocol is also optimized with respect to important parameters such as pH and concentration, and to the polyelectrolyte molecular weight. The advantages of the PACTS technique are that it requires minute amounts of sample and that it is suitable to a broad variety of charged nano-objects. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Production, concentration and titration of pseudotyped HIV-1-based lentiviral vectors.

    PubMed

    Kutner, Robert H; Zhang, Xian-Yang; Reiser, Jakob

    2009-01-01

    Over the past decade, lentiviral vectors have emerged as powerful tools for transgene delivery. The use of lentiviral vectors has become commonplace and applications in the fields of neuroscience, hematology, developmental biology, stem cell biology and transgenesis are rapidly emerging. Also, lentiviral vectors are at present being explored in the context of human clinical trials. Here we describe improved protocols to generate highly concentrated lentiviral vector pseudotypes involving different envelope glycoproteins. In this protocol, vector stocks are prepared by transient transfection using standard cell culture media or serum-free media. Such stocks are then concentrated by ultracentrifugation and/or ion exchange chromatography, or by precipitation using polyethylene glycol 6000, resulting in vector titers of up to 10(10) transducing units per milliliter and above. We also provide reliable real-time PCR protocols to titrate lentiviral vectors based on proviral DNA copies present in genomic DNA extracted from transduced cells or on vector RNA. These production/concentration methods result in high-titer vector preparations that show reduced toxicity compared with lentiviral vectors produced using standard protocols involving ultracentrifugation-based methods. The vector production and titration protocol described here can be completed within 8 d.

  13. Energetics of genome ejection from phage revealed by isothermal titration calorimetry

    NASA Astrophysics Data System (ADS)

    Jeembaeva, Meerim; Jonsson, Bengt; Castelnovo, Martin; Evilevitch, Alex

    2009-03-01

    It has been experimentally shown that ejection of double-stranded DNA from phage is driven by internal pressure reaching tens of atmospheres. This internal pressure is partially responsible for delivery of DNA into the host cell. While several theoretical models and simulations nicely describe the experimental data of internal forces either resisting active packaging or equivalently favoring spontaneous ejection, there are no direct energy measurements available that would help to verify how quantitative these theories are. We performed direct measurements of the enthalpy responsible for DNA ejection from phage λ, using Isothermal Titration Calorimetry. The phage capsids were ``opened'' in vitro by titrating λ into a solution with LamB receptor and the enthalpy of DNA ejection process was measured. In his way, enthalpy stored in λ was determined as a function of packaged DNA length comparing wild-type phage λ (48.5 kb) with a shorter λ-DNA length mutant (37.7 kb). The temperature dependence of the ejection enthalpy was also investigated. The values obtained were in good agreement with existing models and provide a better understanding of ds- DNA packaging and release mechanisms in motor-packaged viruses (e.g., tailed bacteriophages, Herpes Simplex, and adenoviruses).

  14. Initiation of Levodopa-Carbidopa Intestinal Gel Infusion Using Telemedicine (Video Communication System) Facilitates Efficient and Well-Accepted Home Titration in Patients with Advanced Parkinson's Disease.

    PubMed

    Willows, Thomas; Dizdar, Nil; Nyholm, Dag; Widner, Håkan; Grenholm, Peter; Schmiauke, Ursula; Urbom, Anna; Groth, Kristina; Larsson, Jörgen; Permert, Johan; Kjellander, Susanna

    2017-01-01

    Levodopa-carbidopa intestinal gel (LCIG; Duodopa®) is used for continuous infusion in advanced Parkinson's disease. To achieve optimal effect, the LCIG dose is individually titrated, traditionally conducted during hospitalization in Sweden. However, dose adjustment depends on surrounding conditions, physical activity, and emotional stress, which is why titration at home could be beneficial. Telemedicine (TM) using a video communication system offers alternative titration procedures, allowing LCIG initiation at home. Study objectives were to show the feasibility of TM for LCIG home titration, evaluate resource use, and assess patient, neurologist, and nurse satisfaction. Four clinics enrolled 15 patients to observe efficiency and feasibility of TM-based monitoring. Patient median (range) age was 67 (52-73) years and time since diagnosis was 10 (7-23) years. Median time between LCIG initiation and end of TM-assisted titration was 2.8 (2.0-13.8) days. Median time required for home titration by neurologists, nurses, and patients was (hours:minutes) 1 : 14 (0 : 29-1 : 52), 5 : 49 (2 : 46-10 : 3), and 8 : 53 (4 : 11-14 : 11), respectively. Neurologists and nurses considered this to be less time than required for hospital titration. TM allowed patients 92% free time from start to end of titration. Technical problems associated with TM contacts were rare, mostly related to digital link, and quickly resolved. Patients, neurologists, and nurses were satisfied using TM. No serious adverse events were reported; there was one device complaint (tube occlusion). In this study, TM-assisted LCIG titration at home was resource-efficient, technically feasible, well-accepted and was deemed satisfactory by patients, neurologists, and nurses.

  15. Preparation and evaluation of cilnidipine microemulsion

    PubMed Central

    Tandel, Hemal; Raval, Krunal; Nayani, Anil; Upadhay, Manish

    2012-01-01

    Cilnidipine, a calcium channel blocker having neuroprotective action and BCS Class II drug, hence formulating in Microemulsion will increase solubility, absorption and bioavailability. The formulation was prepared using titration method by tocotrienol, tween 20 and transcutol HP as oil, surfactant and co-surfactant and characterized for dilutability, dye solubility, assay (98.39±0.06), pH (6.6±1.5), Viscosity (98±1.0 cps) and Conductivity (0.2±0.09 μS/cm). The formulation was optimized on basis of percentage transmittance (99.269±0.23 at 700 nm), Globule size (13.31±4.3 nm) and zeta potential (–11.4±2.3 mV). Cilnidipine microemulsion was found to be stable for 3 months. PMID:23066184

  16. Differential potentiometric titration: development of a methodology for determining the point of zero charge of metal (hydr)oxides by one titration curve.

    PubMed

    Bourikas, Kyriakos; Kordulis, Christos; Lycourghiotis, Alexis

    2005-06-01

    A new methodology is presented, called differential potentiometric titration (DPT), which allows the determination of the point of zero charge (pzc) of metal (hydr)oxides using only one potentiometric curve. By performing extensive simulations of potentiometric titrations for various model (hydr)oxides, we found that an inflection point in a H+(cons,surf) versus pH potentiometric curve (H+(cons,surf): hydrogen ions consumed on the surface of the (hydr)oxide) and a peak in the corresponding differential curve, dH+(cons,surf)/dpH versus pH, appear at a pH equal to the pzc assumed for a model (hydr)oxide. This distinguishable peak appears at the same position irrespective of the surface ionization and the interfacial model adopted as well as the assumed ionic strength. It was found that the aforementioned peak also appears in the high-resolution differential potentiometric curves experimentally determined for four oxides (SiO2, TiO2, gamma-Al2O3, and MgO) that are widely used in various environmental and other technological applications. The application of DPT to the above-mentioned oxides provided practically the same pzc values as the corresponding ones achieved by using four different techniques as well as the corresponding isoelectric point (iep) values determined by microelectrophoresis. Differences between the pzc and iep values determined using various techniques in the case of MgO were attributed to the increasing dissolution of this oxide as pH decreases and the adsorption of cations (Mg2+, Na+) on the MgO/electrolytic solution interface.

  17. Monitoring of pulmonary mechanics in acute respiratory distress syndrome to titrate therapy.

    PubMed

    Gattinoni, Luciano; Eleonora, Carlesso; Caironi, Pietro

    2005-06-01

    This paper reviews recent findings regarding the respiratory mechanics during acute respiratory distress syndrome as a tool for tailoring its ventilatory management. The pressure-volume curve has been used for many years as a descriptor of the respiratory mechanics in patients affected by acute respiratory distress syndrome. The use of the sigmoidal equation introduced by Venegas for the analysis of the pressure-volume curve seems to be the most rigorous mathematical approach to assessing lung mechanics. Increasing attention has been focused on the deflation limb for titration of positive end-expiratory pressure. Based on physiologic reasoning, a novel parameter, the stress index, has been proposed for tailoring a safe mechanical ventilation, although its clinical impact has still to be proved. Evidence has confirmed that a variety of underlying pathologies may lead to acute respiratory distress syndrome, making unrealistic any attempt to unify the ventilatory approach. Although extensively proposed to tailor mechanical ventilation during acute respiratory distress syndrome, there is no evidence that the pressure-volume curve may be useful in setting a lung-protective strategy in the presence of different potentials for recruitment. The Venegas approach should be the standard analysis of pressure-volume curves. In any patient, the potential for recruitment should be assessed, as a basis for tailoring the most effective mechanical ventilation. Further studies are needed to clarify the potential use of the pressure-volume curve to guide a lung-protective ventilatory strategy.

  18. Copernicus studies of interstellar material in the Perseus II complex. III - The line of sight to Zeta Persei

    NASA Technical Reports Server (NTRS)

    Snow, T. P., Jr.

    1977-01-01

    Ultraviolet spectrophotometric data obtained with Copernicus are used to analyze the distribution, composition, density, temperature, and kinematics of the interstellar material along the line of sight to Zeta Persei. The far-UV extinction curve for the star is evaluated along with the kinematics of the interstellar gas, observations of atomic and molecular hydrogen, curves of growth for neutral and ionized species, atomic abundances and depletions, ionization equilibria, and observations of CO and OH lines. The results show that there are apparently three clouds along the line of sight to Zeta Persei: a main cloud at approximately +13 km/s which contains most of the material and forms all the neutral and molecular lines as well as most of the ionic lines, a second component at +22 km/s which must contribute to the strong UV lines of most ions, and a third component at roughly +2 km/s which gives rise to a strong Si III line at 1206 A. It is also found that the UV extinction curve has a somewhat steep far-UV rise, indicating the presence of a substantial number of small grains, and that about 30% of the hydrogen nuclei over the entire line of sight are in molecular form.

  19. Empiric auto-titrating CPAP in people with suspected obstructive sleep apnea.

    PubMed

    Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A; Gilbert, Gregory E; Strange, Charlie; Herpel, Laura; Frye, Michael D

    2010-04-15

    Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of -3.2 (confidence interval -1.6 to -4.8, p < 0.001) and FOSQ scores improved by a mean of 1.5, (confidence interval 0.5 to 2.7, p = 0.02), whereas scores in the usual-care group did not change (p = NS). Following therapy directed by overnight polysomnography in the control group, there were no differences in ESS or FOSQ between the groups. No adverse events were observed. Empiric auto-CPAP resulted in symptomatic improvement of daytime sleepiness and sleep-related quality of life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional studies are needed to evaluate the applicability

  20. Comparison of a specific HPLC determination of toxic aconite alkaloids in processed Radix aconiti with a titration method of total alkaloids.

    PubMed

    Csupor, Dezso; Borcsa, Botond; Heydel, Barbara; Hohmann, Judit; Zupkó, István; Ma, Yan; Widowitz, Ute; Bauer, Rudolf

    2011-10-01

    In traditional Chinese medicine, Aconitum (Ranunculaceae) roots are only applied after processing. Nevertheless, several cases of poisoning by improperly processed aconite roots have been reported. The aim of this study was to develop a reliable analytical method to assess the amount of toxic aconite alkaloids in commercial aconite roots, and to compare this method with the commonly used total alkaloid content determination by titration. The content of mesaconitine, aconitine, and hypaconitine in 16 commercial samples of processed aconite roots was determined by an HPLC method and the total alkaloid content by indirect titration. Five samples were selected for in vivo toxicological investigation. In most of the commercial samples, toxic alkaloids were not detectable, or only traces were found. In four samples, we could detect >0.04% toxic aconite alkaloids, the highest with a content of 0.16%. The results of HPLC analysis were compared with the results obtained by titration, and no correlation was found between the two methods. The in vivo results reassured the validity of the HPLC determination. Samples with mesaconitine, aconitine, and hypaconitine content below the HPLC detection limit still contained up to 0.2% alkaloids determined by titration. Since titration of alkaloids gives no information selectively on the aconitine-type alkaloid content and toxicity of aconite roots this method is not appropriate for safety assessment. The HPLC method developed by us provides a quick and reliable assessment of toxicity and should be considered as a purity test in pharmacopoeia monographs.