Sample records for zoning building codes

  1. Potential impacts of climate change on the built environment: ASHRAE climate zones, building codes and national energy efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    New, Joshua Ryan; Kumar, Jitendra; Hoffman, Forrest M.

    Statement of the Problem: ASHRAE releases updates to 90.1 “Energy Standard for Buildings except Low-Rise Residential Buildings” every three years resulting in a 3.7%-17.3% increase in energy efficiency for buildings with each release. This is adopted by or informs building codes in nations across the globe, is the National Standard for the US, and individual states elect which release year of the standard they will enforce. These codes are built upon Standard 169 “Climatic Data for Building Design Standards,” the latest 2017 release of which defines climate zones based on 8, 118 weather stations throughout the world and data frommore » the past 8-25 years. This data may not be indicative of the weather that new buildings built today, will see during their upcoming 30-120 year lifespan. Methodology & Theoretical Orientation: Using more modern, high-resolution datasets from climate satellites, IPCC climate models (PCM and HadGCM), high performance computing resources (Titan) and new capabilities for clustering and optimization the authors briefly analyzed different methods for redefining climate zones. Using bottom-up analysis of multiple meteorological variables which were the subject matter, experts selected as being important to energy consumption, rather than the heating/cooling degree days currently used. Findings: We analyzed the accuracy of redefined climate zones, compared to current climate zones and how the climate zones moved under different climate change scenarios, and quantified the accuracy of these methods on a local level, at a national scale for the US. Conclusion & Significance: There is likely to be a significant annual, national energy and cost (billions USD) savings that could be realized by adjusting climate zones to take into account anticipated trends or scenarios in regional weather patterns.« less

  2. 24 CFR 242.78 - Zoning, deed, and building restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Zoning, deed, and building... AUTHORITIES MORTGAGE INSURANCE FOR HOSPITALS Miscellaneous Requirements § 242.78 Zoning, deed, and building... to the project site, and shall comply with all applicable building and other governmental codes...

  3. A Comparative Study on Seismic Analysis of Bangladesh National Building Code (BNBC) with Other Building Codes

    NASA Astrophysics Data System (ADS)

    Bari, Md. S.; Das, T.

    2013-09-01

    Tectonic framework of Bangladesh and adjoining areas indicate that Bangladesh lies well within an active seismic zone. The after effect of earthquake is more severe in an underdeveloped and a densely populated country like ours than any other developed countries. Bangladesh National Building Code (BNBC) was first established in 1993 to provide guidelines for design and construction of new structure subject to earthquake ground motions in order to minimize the risk to life for all structures. A revision of BNBC 1993 is undergoing to make this up to date with other international building codes. This paper aims at the comparison of various provisions of seismic analysis as given in building codes of different countries. This comparison will give an idea regarding where our country stands when it comes to safety against earth quake. Primarily, various seismic parameters in BNBC 2010 (draft) have been studied and compared with that of BNBC 1993. Later, both 1993 and 2010 edition of BNBC codes have been compared graphically with building codes of other countries such as National Building Code of India 2005 (NBC-India 2005), American Society of Civil Engineering 7-05 (ASCE 7-05). The base shear/weight ratios have been plotted against the height of the building. The investigation in this paper reveals that BNBC 1993 has the least base shear among all the codes. Factored Base shear values of BNBC 2010 are found to have increased significantly than that of BNBC 1993 for low rise buildings (≤20 m) around the country than its predecessor. Despite revision of the code, BNBC 2010 (draft) still suggests less base shear values when compared to the Indian and American code. Therefore, this increase in factor of safety against the earthquake imposed by the proposed BNBC 2010 code by suggesting higher values of base shear is appreciable.

  4. A long-term, integrated impact assessment of alternative building energy code scenarios in China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Eom, Jiyong; Evans, Meredydd

    2014-04-01

    China is the second largest building energy user in the world, ranking first and third in residential and commercial energy consumption. Beginning in the early 1980s, the Chinese government has developed a variety of building energy codes to improve building energy efficiency and reduce total energy demand. This paper studies the impact of building energy codes on energy use and CO2 emissions by using a detailed building energy model that represents four distinct climate zones each with three building types, nested in a long-term integrated assessment framework GCAM. An advanced building stock module, coupled with the building energy model, ismore » developed to reflect the characteristics of future building stock and its interaction with the development of building energy codes in China. This paper also evaluates the impacts of building codes on building energy demand in the presence of economy-wide carbon policy. We find that building energy codes would reduce Chinese building energy use by 13% - 22% depending on building code scenarios, with a similar effect preserved even under the carbon policy. The impact of building energy codes shows regional and sectoral variation due to regionally differentiated responses of heating and cooling services to shell efficiency improvement.« less

  5. Tribal Green Building Administrative Code Example

    EPA Pesticide Factsheets

    This Tribal Green Building Administrative Code Example can be used as a template for technical code selection (i.e., building, electrical, plumbing, etc.) to be adopted as a comprehensive building code.

  6. Impacts of Model Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Athalye, Rahul A.; Sivaraman, Deepak; Elliott, Douglas B.

    The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program; this study looked more broadly at overall code impacts. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions atmore » the state level and at aggregated levels. This analysis does not represent all potential savings from energy codes in the U.S. because it excludes several states which have codes which are fundamentally different from the national model energy codes or which do not have state-wide codes. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when buildings comply with the code. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. Delayed adoption of a model code and incomplete compliance with the code’s requirements erode potential savings. The contributions of all three phases are crucial to the overall impact of codes, and are considered in this assessment.« less

  7. Country Report on Building Energy Codes in Australia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shui, Bin; Evans, Meredydd; Somasundaram, Sriram

    2009-04-02

    This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in Australia, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, and lighting) for commercial and residential buildings in Australia.

  8. Assessing Potential Energy Cost Savings from Increased Energy Code Compliance in Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.

    The US Department of Energy’s most recent commercial energy code compliance evaluation efforts focused on determining a percent compliance rating for states to help them meet requirements under the American Recovery and Reinvestment Act (ARRA) of 2009. That approach included a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. With its binary approach to compliance determination, the previous methodology failed to answer some important questions. In particular, how much energy cost could be saved by better compliance with the commercial energymore » code and what are the relative priorities of code requirements from an energy cost savings perspective? This paper explores an analytical approach and pilot study using a single building type and climate zone to answer those questions.« less

  9. Country Report on Building Energy Codes in Canada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shui, Bin; Evans, Meredydd

    2009-04-06

    This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America . This reports gives an overview of the development of building energy codes in Canada, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, lighting, and water heating) for commercial and residential buildingsmore » in Canada.« less

  10. Kayenta Township Building & Safety Department, Tribal Green Building Code Summit Presentation

    EPA Pesticide Factsheets

    Tribal Green Building Code Summit Presentation by Kayenta Township Building & Safety Department showing how they established the building department, developed a code adoption and enforcement process, and hired staff to carry out the work.

  11. Building codes : obstacle or opportunity?

    Treesearch

    Alberto Goetzl; David B. McKeever

    1999-01-01

    Building codes are critically important in the use of wood products for construction. The codes contain regulations that are prescriptive or performance related for various kinds of buildings and construction types. A prescriptive standard might dictate that a particular type of material be used in a given application. A performance standard requires that a particular...

  12. National Tribal Building Codes Summit

    EPA Pesticide Factsheets

    National Tribal Building Codes summit statement developed to support tribes interested in adopting green and culturally-appropriate building systems to ensure safe, sustainable, affordable, and culturally-appropriate buildings on tribal lands.

  13. Flood-resilient waterfront development in New York City: bridging flood insurance, building codes, and flood zoning.

    PubMed

    Aerts, Jeroen C J H; Botzen, W J Wouter

    2011-06-01

    Waterfronts are attractive areas for many-often competing-uses in New York City (NYC) and are seen as multifunctional locations for economic, environmental, and social activities on the interface between land and water. The NYC waterfront plays a crucial role as a first line of flood defense and in managing flood risk and protecting the city from future climate change and sea-level rise. The city of New York has embarked on a climate adaptation program (PlaNYC) outlining the policies needed to anticipate the impacts of climate change. As part of this policy, the Department of City Planning has recently prepared Vision 2020: New York City Comprehensive Waterfront Plan for the over 500 miles of NYC waterfront (NYC-DCP, 2011). An integral part of the vision is to improve resilience to climate change and sea-level rise. This study seeks to provide guidance for advancing the goals of NYC Vision 2020 by assessing how flood insurance, flood zoning, and building code policies can contribute to waterfront development that is more resilient to climate change. © 2011 New York Academy of Sciences.

  14. Building Energy Codes: Policy Overview and Good Practices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, Sadie

    2016-02-19

    Globally, 32% of total final energy consumption is attributed to the building sector. To reduce energy consumption, energy codes set minimum energy efficiency standards for the building sector. With effective implementation, building energy codes can support energy cost savings and complementary benefits associated with electricity reliability, air quality improvement, greenhouse gas emission reduction, increased comfort, and economic and social development. This policy brief seeks to support building code policymakers and implementers in designing effective building code programs.

  15. Residential Building Energy Code Field Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. Bartlett, M. Halverson, V. Mendon, J. Hathaway, Y. Xie

    This document presents a methodology for assessing baseline energy efficiency in new single-family residential buildings and quantifying related savings potential. The approach was developed by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) Building Energy Codes Program with the objective of assisting states as they assess energy efficiency in residential buildings and implementation of their building energy codes, as well as to target areas for improvement through energy codes and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data setmore » to represent baseline construction practices across U.S. states.« less

  16. 24 CFR 200.72 - Zoning, deed and building restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Zoning, deed and building... Zoning, deed and building restrictions. The project when completed shall not violate any material zoning or deed restrictions applicable to the project site, and shall comply with all applicable building...

  17. An international survey of building energy codes and their implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Meredydd; Roshchanka, Volha; Graham, Peter

    Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy demand from buildings. Access to benefits of building energy codes depends on comprehensive coverage of buildings by type, age, size, andmore » geographic location; an implementation framework that involves a certified agency to inspect construction at critical stages; and independently tested, rated, and labeled building energy materials. Training and supporting tools are another element of successful code implementation, and their role is growing in importance, given the increasing flexibility and complexity of building energy codes. Some countries have also introduced compliance evaluation and compliance checking protocols to improve implementation. This article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less

  18. Building a Better Campus: An Update on Building Codes.

    ERIC Educational Resources Information Center

    Madden, Michael J.

    2002-01-01

    Discusses the implications for higher education institutions in terms of facility planning, design, construction, and renovation of the move from regionally-developed model-building codes to two international sets of codes. Also addresses the new performance-based design option within the codes. (EV)

  19. An international survey of building energy codes and their implementation

    DOE PAGES

    Evans, Meredydd; Roshchanka, Volha; Graham, Peter

    2017-08-01

    Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less

  20. An international survey of building energy codes and their implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Meredydd; Roshchanka, Volha; Graham, Peter

    Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less

  1. Building Standards and Codes for Energy Conservation

    ERIC Educational Resources Information Center

    Gross, James G.; Pierlert, James H.

    1977-01-01

    Current activity intended to lead to energy conservation measures in building codes and standards is reviewed by members of the Office of Building Standards and Codes Services of the National Bureau of Standards. For journal availability see HE 508 931. (LBH)

  2. Building Energy Efficiency in India: Compliance Evaluation of Energy Conservation Building Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Evans, Meredydd; Delgado, Alison

    India is experiencing unprecedented construction boom. The country doubled its floorspace between 2001 and 2005 and is expected to add 35 billion m2 of new buildings by 2050. Buildings account for 35% of total final energy consumption in India today, and building energy use is growing at 8% annually. Studies have shown that carbon policies will have little effect on reducing building energy demand. Chaturvedi et al. predicted that, if there is no specific sectoral policies to curb building energy use, final energy demand of the Indian building sector will grow over five times by the end of this century,more » driven by rapid income and population growth. The growing energy demand in buildings is accompanied by a transition from traditional biomass to commercial fuels, particularly an increase in electricity use. This also leads to a rapid increase in carbon emissions and aggravates power shortage in India. Growth in building energy use poses challenges to the Indian government. To curb energy consumption in buildings, the Indian government issued the Energy Conservation Building Code (ECBC) in 2007, which applies to commercial buildings with a connected load of 100 kW or 120kVA. It is predicted that the implementation of ECBC can help save 25-40% of energy, compared to reference buildings without energy-efficiency measures. However, the impact of ECBC depends on the effectiveness of its enforcement and compliance. Currently, the majority of buildings in India are not ECBC-compliant. The United Nations Development Programme projected that code compliance in India would reach 35% by 2015 and 64% by 2017. Whether the projected targets can be achieved depends on how the code enforcement system is designed and implemented. Although the development of ECBC lies in the hands of the national government – the Bureau of Energy Efficiency under the Ministry of Power, the adoption and implementation of ECBC largely relies on state and local governments. Six years after

  3. Building code compliance and enforcement: The experience of San Francisco's residential energy conservation ordinance and California's building standards for new construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vine, E.

    1990-11-01

    As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing to construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. 12 refs., 5 tabs.« less

  4. Climatic zoning for the calculation of the thermal demand of buildings in Extremadura (Spain)

    NASA Astrophysics Data System (ADS)

    Moral, Francisco J.; Pulido, Elena; Ruíz, Antonio; López, Fernando

    2017-08-01

    The present work reports on a methodology to assess the climatic severity of a particular geographic region as compared to specific information available in the current regulations. The viability for each of the 387 municipalities in the Autonomous Community of Extremadura (Spain) is analysed, making a distinction between those with reliable climate reports and those for which no such information is available. In the case study, although the weather conditions in Extremadura are quite homogeneous according to the Spanish Technical Building Code (STBC 2015) classification and most areas are associated to zone C4 (soft winters and hot summers), the southern area in the region is associated to zone D1, similar to the north of Spain, where winters and summers are cool, which does not coincide with the actual climate in the south of Extremadura. The general climatic homogeneity in Extremadura was also highlighted with the new procedure, predominating zone C4, but unexpected or unreal climatic zoning was not generated, giving place to a consistent spatial distribution of zones throughout the region. Consequently, the proposed method allows a more accurate climatic zoning of any region in agreement with the Spanish legislation on energy efficiency in buildings, which would enhance the setting of thermal demand rates according to the actual climatic characterisation of the area in which a particular municipality is located.

  5. Building codes: An often overlooked determinant of health.

    PubMed

    Chauvin, James; Pauls, Jake; Strobl, Linda

    2016-05-01

    Although the vast majority of the world's population spends most of their time in buildings, building codes are not often thought of as 'determinants of health'. The standards that govern the design, construction, and use of buildings affect our health, security, safety, and well-being. This is true for dwellings, schools, and universities, shopping centers, places of recreation, places of worship, health-care facilities, and workplaces. We urge proactive engagement by the global public health community in developing these codes, and in the design and implementation of health protection and health promotion activities intended to reduce the risk of injury, disability, and death, particularly when due to poor building code adoption/adaption, application, and enforcement.

  6. Implementation of Energy Code Controls Requirements in New Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Hart, Philip R.; Hatten, Mike

    Most state energy codes in the United States are based on one of two national model codes; ANSI/ASHRAE/IES 90.1 (Standard 90.1) or the International Code Council (ICC) International Energy Conservation Code (IECC). Since 2004, covering the last four cycles of Standard 90.1 updates, about 30% of all new requirements have been related to building controls. These requirements can be difficult to implement and verification is beyond the expertise of most building code officials, yet the assumption in studies that measure the savings from energy codes is that they are implemented and working correctly. The objective of the current research ismore » to evaluate the degree to which high impact controls requirements included in commercial energy codes are properly designed, commissioned and implemented in new buildings. This study also evaluates the degree to which these control requirements are realizing their savings potential. This was done using a three-step process. The first step involved interviewing commissioning agents to get a better understanding of their activities as they relate to energy code required controls measures. The second involved field audits of a sample of commercial buildings to determine whether the code required control measures are being designed, commissioned and correctly implemented and functioning in new buildings. The third step includes compilation and analysis of the information gather during the first two steps. Information gathered during these activities could be valuable to code developers, energy planners, designers, building owners, and building officials.« less

  7. Building Codes and Regulations.

    ERIC Educational Resources Information Center

    Fisher, John L.

    The hazard of fire is of great concern to libraries due to combustible books and new plastics used in construction and interiors. Building codes and standards can offer architects and planners guidelines to follow but these standards should be closely monitored, updated, and researched for fire prevention. (DS)

  8. The Influence of Building Codes on Recreation Facility Design.

    ERIC Educational Resources Information Center

    Morrison, Thomas A.

    1989-01-01

    Implications of building codes upon design and construction of recreation facilities are investigated (national building codes, recreation facility standards, and misperceptions of design requirements). Recreation professionals can influence architectural designers to correct past deficiencies, but they must understand architectural and…

  9. Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Bing; Zhang, Jian; Chen, Yan

    This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort,more » PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings

  10. SAFETY IN THE DESIGN OF SCIENCE LABORATORIES AND BUILDING CODES.

    ERIC Educational Resources Information Center

    HOROWITZ, HAROLD

    THE DESIGN OF COLLEGE AND UNIVERSITY BUILDINGS USED FOR SCIENTIFIC RESEARCH AND EDUCATION IS DISCUSSED IN TERMS OF LABORATORY SAFETY AND BUILDING CODES AND REGULATIONS. MAJOR TOPIC AREAS ARE--(1) SAFETY RELATED DESIGN FEATURES OF SCIENCE LABORATORIES, (2) LABORATORY SAFETY AND BUILDING CODES, AND (3) EVIDENCE OF UNSAFE DESIGN. EXAMPLES EMPHASIZE…

  11. Mandating better buildings: a global review of building codes and prospects for improvement in the United States

    DOE PAGES

    Sun, Xiaojing; Brown, Marilyn A.; Cox, Matt; ...

    2015-03-11

    This paper provides a global overview of the design, implementation, and evolution of building energy codes. Reflecting alternative policy goals, building energy codes differ significantly across the United States, the European Union, and China. This review uncovers numerous innovative practices including greenhouse gas emissions caps per square meter of building space, energy performance certificates with retrofit recommendations, and inclusion of renewable energy to achieve “nearly zero-energy buildings”. These innovations motivated an assessment of an aggressive commercial building code applied to all US states, requiring both new construction and buildings with major modifications to comply with the latest version of themore » ASHRAE 90.1 Standards. Using the National Energy Modeling System (NEMS), we estimate that by 2035, such building codes in the United States could reduce energy for space heating, cooling, water heating and lighting in commercial buildings by 16%, 15%, 20% and 5%, respectively. Impacts on different fuels and building types, energy rates and bills as well as pollution emission reductions are also examined.« less

  12. A MODEL BUILDING CODE ARTICLE ON FALLOUT SHELTERS WITH RECOMMENDATIONS FOR INCLUSION OF REQUIREMENTS FOR FALLOUT SHELTER CONSTRUCTION IN FOUR NATIONAL MODEL BUILDING CODES.

    ERIC Educational Resources Information Center

    American Inst. of Architects, Washington, DC.

    A MODEL BUILDING CODE FOR FALLOUT SHELTERS WAS DRAWN UP FOR INCLUSION IN FOUR NATIONAL MODEL BUILDING CODES. DISCUSSION IS GIVEN OF FALLOUT SHELTERS WITH RESPECT TO--(1) NUCLEAR RADIATION, (2) NATIONAL POLICIES, AND (3) COMMUNITY PLANNING. FALLOUT SHELTER REQUIREMENTS FOR SHIELDING, SPACE, VENTILATION, CONSTRUCTION, AND SERVICES SUCH AS ELECTRICAL…

  13. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 12 2013-01-01 2013-01-01 false Voluntary National Model Building Codes E Exhibit E... National Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of...

  14. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 12 2014-01-01 2013-01-01 true Voluntary National Model Building Codes E Exhibit E to... Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of this...

  15. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 12 2012-01-01 2012-01-01 false Voluntary National Model Building Codes E Exhibit E... National Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of...

  16. Building America Top Innovations 2012: Building Science-Based Climate Maps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2013-01-01

    This Building America Top Innovations profile describes the Building America-developed climate zone map, which serves as a consistent framework for energy-efficiency requirements in the national model energy code starting with the 2004 IECC Supplement and the ASHRAE 90.1 2004 edition. The map also provides a critical foundation for climate-specific guidance in the widely disseminated EEBA Builder Guides and Building America Best Practice Guides.

  17. Performance-based building codes: a call for injury prevention indicators that bridge health and building sectors.

    PubMed

    Edwards, N

    2008-10-01

    The international introduction of performance-based building codes calls for a re-examination of indicators used to monitor their implementation. Indicators used in the building sector have a business orientation, target the life cycle of buildings, and guide asset management. In contrast, indicators used in the health sector focus on injury prevention, have a behavioural orientation, lack specificity with respect to features of the built environment, and do not take into account patterns of building use or building longevity. Suggestions for metrics that bridge the building and health sectors are discussed. The need for integrated surveillance systems in health and building sectors is outlined. It is time to reconsider commonly used epidemiological indicators in the field of injury prevention and determine their utility to address the accountability requirements of performance-based codes.

  18. Overcoming Codes and Standards Barriers to Innovations in Building Energy Efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Pamala C.; Gilbride, Theresa L.

    2015-02-15

    In this journal article, the authors discuss approaches to overcoming building code barriers to energy-efficiency innovations in home construction. Building codes have been a highly motivational force for increasing the energy efficiency of new homes in the United States in recent years. But as quickly as the codes seem to be changing, new products are coming to the market at an even more rapid pace, sometimes offering approaches and construction techniques unthought of when the current code was first proposed, which might have been several years before its adoption by various jurisdictions. Due to this delay, the codes themselves canmore » become barriers to innovations that might otherwise be helping to further increase the efficiency, comfort, health or durability of new homes. . The U.S. Department of Energy’s Building America, a program dedicated to improving the energy efficiency of America’s housing stock through research and education, is working with the U.S. housing industry through its research teams to help builders identify and remove code barriers to innovation in the home construction industry. The article addresses several approaches that builders use to achieve approval for innovative building techniques when code barriers appear to exist.« less

  19. 75 FR 20833 - Building Energy Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy [Docket No. EERE-2010-BT-BC-0012] Building Energy Codes AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Request for Information. SUMMARY: The U.S. Department of Energy (DOE) is soliciting...

  20. Pinoleville Pomo Nation Tribal Green Building Code

    EPA Pesticide Factsheets

    The Pinoleville Pomo Nation (PPN) worked with the U.S. Environmental Protection Agency (EPA) and the Development Center for Appropriate Technology (DCAT) to create this framework for tribal building codes.

  1. An Assessment of Actual and Potential Building Climate Zone Change and Variability From the Last 30 Years Through 2100 Using NASA's MERRA and CMIP5 Simulations

    NASA Technical Reports Server (NTRS)

    Stackhouse, Paul W., Jr.; Chandler, William S.; Hoell, James M.; Westberg, David; Zhang, Taiping

    2015-01-01

    Background: In the US, residential and commercial building infrastructure combined consumes about 40% of total energy usage and emits about 39% of total CO2 emission (DOE/EIA "Annual Energy Outlook 2013"). Building codes, as used by local and state enforcement entities are typically tied to the dominant climate within an enforcement jurisdiction classified according to various climate zones. These climate zones are based upon a 30-year average of local surface observations and are developed by DOE and ASHRAE. Establishing the current variability and potential changes to future building climate zones is very important for increasing the energy efficiency of buildings and reducing energy costs and emissions in the future. Objectives: This paper demonstrates the usefulness of using NASA's Modern Era Retrospective-analysis for Research and Applications (MERRA) atmospheric data assimilation to derive the DOE/ASHRAE building climate zone maps and then using MERRA to define the last 30 years of variability in climate zones for the Continental US. An atmospheric assimilation is a global atmospheric model optimized to satellite, atmospheric and surface in situ measurements. Using MERRA as a baseline, we then evaluate the latest Climate Model Inter-comparison Project (CMIP) climate model Version 5 runs to assess potential variability in future climate zones under various assumptions. Methods: We derive DOE/ASHRAE building climate zones using surface and temperature data products from MERRA. We assess these zones using the uncertainties derived by comparison to surface measurements. Using statistical tests, we evaluate variability of the climate zones in time and assess areas in the continental US for statistically significant trends by region. CMIP 5 produced a data base of over two dozen detailed climate model runs under various greenhouse gas forcing assumptions. We evaluate the variation in building climate zones for 3 different decades using an ensemble and quartile

  2. VizieR Online Data Catalog: Habitable zone code (Valle+, 2014)

    NASA Astrophysics Data System (ADS)

    Valle, G.; Dell'Omodarme, M.; Prada Moroni, P. G.; Degl'Innocenti, S.

    2014-06-01

    A C computation code that provide in output the distance dm (i for which the duration of habitability is longest, the corresponding duration tm (in Gyr), the width W (in AU) of the zone for which the habitability lasts tm/2, the inner (Ri) and outer (Ro) boundaries of the 4Gyr continuously habitable zone. The code read the input file HZ-input.dat, containing in each row the mass of the host star (range: 0.70-1.10M⊙), its metallicity (either Z (range: 0.005-0.004) or [Fe/H]), the helium-to-metal enrichment ratio (range: 1-3, standard value = 2), the equilibrium temperature for habitable zone outer boundary computation (range: 169-203K) and the planet Bond Albedo (range: 0.0-1.0, Earth = 0.3). The output is printed on-screen. Compilation: just use your favorite C compiler: gcc hz.c -lm -o HZ (2 data files).

  3. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... National Model Building Codes The following documents address the health and safety aspects of buildings... International, Inc., 4051 West Flossmoor Road, Country Club Hills, Illinois 60477. 2 Southern Building Code Congress International, Inc., 900 Montclair Road, Birmingham, Alabama 35213-1206. 3 International...

  4. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Voluntary National Model Building Codes E Exhibit E... HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY... National Model Building Codes The following documents address the health and safety aspects of buildings...

  5. Alternative Formats to Achieve More Efficient Energy Codes for Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, David R.; Rosenberg, Michael I.; Halverson, Mark A.

    2013-01-26

    This paper identifies and examines several formats or structures that could be used to create the next generation of more efficient energy codes and standards for commercial buildings. Pacific Northwest National Laboratory (PNNL) is funded by the U.S. Department of Energy’s Building Energy Codes Program (BECP) to provide technical support to the development of ANSI/ASHRAE/IES Standard 90.1. While the majority of PNNL’s ASHRAE Standard 90.1 support focuses on developing and evaluating new requirements, a portion of its work involves consideration of the format of energy standards. In its current working plan, the ASHRAE 90.1 committee has approved an energy goalmore » of 50% improvement in Standard 90.1-2013 relative to Standard 90.1-2004, and will likely be considering higher improvement targets for future versions of the standard. To cost-effectively achieve the 50% goal in manner that can gain stakeholder consensus, formats other than prescriptive must be considered. Alternative formats that include reducing the reliance on prescriptive requirements may make it easier to achieve these aggressive efficiency levels in new codes and standards. The focus on energy code and standard formats is meant to explore approaches to presenting the criteria that will foster compliance, enhance verification, and stimulate innovation while saving energy in buildings. New formats may also make it easier for building designers and owners to design and build the levels of efficiency called for in the new codes and standards. This paper examines a number of potential formats and structures, including prescriptive, performance-based (with sub-formats of performance equivalency and performance targets), capacity constraint-based, and outcome-based. The paper also discusses the pros and cons of each format from the viewpoint of code users and of code enforcers.« less

  6. New "Risk-Targeted" Seismic Maps Introduced into Building Codes

    USGS Publications Warehouse

    Luco, Nicholas; Garrett, B.; Hayes, J.

    2012-01-01

    Throughout most municipalities of the United States, structural engineers design new buildings using the U.S.-focused International Building Code (IBC). Updated editions of the IBC are published every 3 years. The latest edition (2012) contains new "risk-targeted maximum considered earthquake" (MCER) ground motion maps, which are enabling engineers to incorporate a more consistent and better defined level of seismic safety into their building designs.

  7. Energy Efficiency Program Administrators and Building Energy Codes

    EPA Pesticide Factsheets

    Explore how energy efficiency program administrators have helped advance building energy codes at federal, state, and local levels—using technical, institutional, financial, and other resources—and discusses potential next steps.

  8. Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.

    2016-08-22

    An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed officemore » buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.« less

  9. Building Code Compliance and Enforcement: The Experience of SanFrancisco's Residential Energy Conservation Ordinanace and California'sBuildign Standards for New Construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vine, E.

    1990-11-01

    As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. Because statewide codes are enforced by local officials, these problems may increase over time as energy standards change and become more complex and as other standards (eg

  10. Optimization for energy efficiency of underground building envelope thermal performance in different climate zones of China

    NASA Astrophysics Data System (ADS)

    Shi, Luyang; Liu, Jing; Zhang, Huibo

    2017-11-01

    The object of this article is to investigate the influence of thermal performance of envelopes in shallow-buried buildings on energy consumption for different climate zones of China. For the purpose of this study, an effective building energy simulation tool (DeST) developed by Tsinghua University was chosen to model the heat transfer in underground buildings. Based on the simulative results, energy consumption for heating and cooling for the whole year was obtained. The results showed that the relationship between energy consumption and U-value of envelopes for underground buildings is different compared with above-ground buildings: improving thermal performance of exterior walls cannot reduce energy consumption, on the contrary, may result in more energy cost. Besides, it is can be derived that optimized U-values of underground building envelopes vary with climate zones of China in this study. For severe cold climate zone, the optimized U-value of underground building envelopes is 0.8W/(m2·K); for cold climate zone, the optimized U-value is 1.5W/(m2·K); for warm climate zone, the U-value is 2.0W/(m2·K).

  11. Potential Job Creation in Minnesota as a Result of Adopting New Residential Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less

  12. Potential Job Creation in Tennessee as a Result of Adopting New Residential Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less

  13. Potential Job Creation in Nevada as a Result of Adopting New Residential Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less

  14. 76 FR 64924 - Updating State Residential Building Energy Efficiency Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-19

    ...) considers high-rise (greater than three stories) multifamily residential buildings and hotel, motel, and..., duplexes, townhouses, row houses, and low-rise multifamily buildings (not greater than three stories) such... pumps as compared to other electric heating technologies, this code change is expected to increase the...

  15. Demand Shifting with Thermal Mass in Large Commercial Buildings in a California Hot Climate Zone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Peng; Yin, Rongxin; Brown, Carrie

    2009-06-01

    The potential for using building thermal mass for load shifting and peak energy demand reduction has been demonstrated in a number of simulation, laboratory, and field studies. Previous Lawrence Berkeley National Laboratory research has demonstrated that the approach is very effective in cool and moderately warm climate conditions (California Climate Zones 2-4). However, this method had not been tested in hotter climate zones. This project studied the potential of pre-cooling the building early in the morning and increasing temperature setpoints during peak hours to reduce cooling-related demand in two typical office buildings in hotter California climates ? one in Visaliamore » (CEC Climate Zone 13) and the other in San Bernardino (CEC Climate Zone 10). The conclusion of the work to date is that pre-cooling in hotter climates has similar potential to that seen previously in cool and moderate climates. All other factors being equal, results to date indicate that pre-cooling increases the depth (kW) and duration (kWh) of the possible demand shed of a given building. The effectiveness of night pre-cooling in typical office building under hot weather conditions is very limited. However, night pre-cooling is helpful for office buildings with an undersized HVAC system. Further work is required to duplicate the tests in other typical buildings and in other hot climate zones and prove that pre-cooling is truly effective.« less

  16. Evaluating the benefits of commercial building energy codes and improving federal incentives for code adoption.

    PubMed

    Gilbraith, Nathaniel; Azevedo, Inês L; Jaramillo, Paulina

    2014-12-16

    The federal government has the goal of decreasing commercial building energy consumption and pollutant emissions by incentivizing the adoption of commercial building energy codes. Quantitative estimates of code benefits at the state level that can inform the size and allocation of these incentives are not available. We estimate the state-level climate, environmental, and health benefits (i.e., social benefits) and reductions in energy bills (private benefits) of a more stringent code (ASHRAE 90.1-2010) relative to a baseline code (ASHRAE 90.1-2007). We find that reductions in site energy use intensity range from 93 MJ/m(2) of new construction per year (California) to 270 MJ/m(2) of new construction per year (North Dakota). Total annual benefits from more stringent codes total $506 million for all states, where $372 million are from reductions in energy bills, and $134 million are from social benefits. These total benefits range from $0.6 million in Wyoming to $49 million in Texas. Private benefits range from $0.38 per square meter in Washington State to $1.06 per square meter in New Hampshire. Social benefits range from $0.2 per square meter annually in California to $2.5 per square meter in Ohio. Reductions in human/environmental damages and future climate damages account for nearly equal shares of social benefits.

  17. Potential Job Creation in Rhode Island as a Result of Adopting New Residential Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less

  18. 76 FR 57982 - Building Energy Codes Cost Analysis

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-19

    ... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy [Docket No. EERE-2011-BT-BC-0046] Building Energy Codes Cost Analysis Correction In notice document 2011-23236 beginning on page... heading ``Table 1. Cash flow components'' should read ``Table 7. Cash flow components''. [FR Doc. C1-2011...

  19. Multi-Zone Liquid Thrust Chamber Performance Code with Domain Decomposition for Parallel Processing

    NASA Technical Reports Server (NTRS)

    Navaz, Homayun K.

    2002-01-01

    Computational Fluid Dynamics (CFD) has considerably evolved in the last decade. There are many computer programs that can perform computations on viscous internal or external flows with chemical reactions. CFD has become a commonly used tool in the design and analysis of gas turbines, ramjet combustors, turbo-machinery, inlet ducts, rocket engines, jet interaction, missile, and ramjet nozzles. One of the problems of interest to NASA has always been the performance prediction for rocket and air-breathing engines. Due to the complexity of flow in these engines it is necessary to resolve the flowfield into a fine mesh to capture quantities like turbulence and heat transfer. However, calculation on a high-resolution grid is associated with a prohibitively increasing computational time that can downgrade the value of the CFD for practical engineering calculations. The Liquid Thrust Chamber Performance (LTCP) code was developed for NASA/MSFC (Marshall Space Flight Center) to perform liquid rocket engine performance calculations. This code is a 2D/axisymmetric full Navier-Stokes (NS) solver with fully coupled finite rate chemistry and Eulerian treatment of liquid fuel and/or oxidizer droplets. One of the advantages of this code has been the resemblance of its input file to the JANNAF (Joint Army Navy NASA Air Force Interagency Propulsion Committee) standard TDK code, and its automatic grid generation for JANNAF defined combustion chamber wall geometry. These options minimize the learning effort for TDK users, and make the code a good candidate for performing engineering calculations. Although the LTCP code was developed for liquid rocket engines, it is a general-purpose code and has been used for solving many engineering problems. However, the single zone formulation of the LTCP has limited the code to be applicable to problems with complex geometry. Furthermore, the computational time becomes prohibitively large for high-resolution problems with chemistry, two

  20. Building code challenging the ethics behind adobe architecture in North Cyprus.

    PubMed

    Hurol, Yonca; Yüceer, Hülya; Şahali, Öznem

    2015-04-01

    Adobe masonry is part of the vernacular architecture of Cyprus. Thus, it is possible to use this technology in a meaningful way on the island. On the other hand, although adobe architecture is more sustainable in comparison to other building technologies, the use of it is diminishing in North Cyprus. The application of Turkish building code in the north of the island has created complications in respect of the use of adobe masonry, because this building code demands that reinforced concrete vertical tie-beams are used together with adobe masonry. The use of reinforced concrete elements together with adobe masonry causes problems in relation to the climatic response of the building as well as causing other technical and aesthetic problems. This situation makes the design of adobe masonry complicated and various types of ethical problems also emerge. The objective of this article is to analyse the ethical problems which arise as a consequence of the restrictive character of the building code, by analysing two case studies and conducting an interview with an architect who was involved with the use of adobe masonry in North Cyprus. According to the results of this article there are ethical problems at various levels in the design of both case studies. These problems are connected to the responsibilities of architects in respect of the social benefit, material production, aesthetics and affordability of the architecture as well as presenting distrustful behaviour where the obligations of architects to their clients is concerned.

  1. ICAN Computer Code Adapted for Building Materials

    NASA Technical Reports Server (NTRS)

    Murthy, Pappu L. N.

    1997-01-01

    The NASA Lewis Research Center has been involved in developing composite micromechanics and macromechanics theories over the last three decades. These activities have resulted in several composite mechanics theories and structural analysis codes whose applications range from material behavior design and analysis to structural component response. One of these computer codes, the Integrated Composite Analyzer (ICAN), is designed primarily to address issues related to designing polymer matrix composites and predicting their properties - including hygral, thermal, and mechanical load effects. Recently, under a cost-sharing cooperative agreement with a Fortune 500 corporation, Master Builders Inc., ICAN was adapted to analyze building materials. The high costs and technical difficulties involved with the fabrication of continuous-fiber-reinforced composites sometimes limit their use. Particulate-reinforced composites can be thought of as a viable alternative. They are as easily processed to near-net shape as monolithic materials, yet have the improved stiffness, strength, and fracture toughness that is characteristic of continuous-fiber-reinforced composites. For example, particlereinforced metal-matrix composites show great potential for a variety of automotive applications, such as disk brake rotors, connecting rods, cylinder liners, and other hightemperature applications. Building materials, such as concrete, can be thought of as one of the oldest materials in this category of multiphase, particle-reinforced materials. The adaptation of ICAN to analyze particle-reinforced composite materials involved the development of new micromechanics-based theories. A derivative of the ICAN code, ICAN/PART, was developed and delivered to Master Builders Inc. as a part of the cooperative activity.

  2. Understanding Energy Code Acceptance within the Alaska Building Community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mapes, Terry S.

    2012-02-14

    This document presents the technical assistance provided to the Alaska Home Financing Corporation on behalf of PNNL regarding the assessment of attitudes toward energy codes within the building community in Alaska. It includes a summary of the existing situation and specific assistance requested by AHFC, the results of a questionnaire designed for builders surveyed in a suburban area of Anchorage, interviews with a lender, a building official, and a research specialist, and recommendations for future action by AHFC.

  3. Using Third-Party Inspectors in Building Energy Codes Enforcement in India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Evans, Meredydd; Kumar, Pradeep

    India is experiencing fast income growth and urbanization, and this leads to unprecedented increases in demand for building energy services and resulting energy consumption. In response to rapid growth in building energy use, the Government of India issued the Energy Conservation Building Code (ECBC) in 2007, which is consistent with and based on the 2001 Energy Conservation Act. ECBC implementation has been voluntary since its enactment and a few states have started to make progress towards mandatory implementation. Rajasthan is the first state in India to adopt ECBC as a mandatory code. The State adopted ECBC with minor additions onmore » March 28, 2011 through a stakeholder process; it became mandatory in Rajasthan on September 28, 2011. Tamil Nadu, Gujarat, and Andhra Pradesh have started to draft an implementation roadmap and build capacity for its implementation. The Bureau of Energy Efficiency (BEE) plans to encourage more states to adopt ECBC in the near future, including Haryana, Uttar Pradesh, Karnataka, Maharashtra, West Bengal, and Delhi. Since its inception, India has applied the code on a voluntary basis, but the Government of India is developing a strategy to mandate compliance. Implementing ECBC requires coordination between the Ministry of Power and the Ministry of Urban Development at the national level as well as interdepartmental coordination at the state level. One challenge is that the Urban Local Bodies (ULBs), the enforcement entities of building by-laws, lack capacity to implement ECBC effectively. For example, ULBs in some states might find the building permitting procedures to be too complex; in other cases, lack of awareness and technical knowledge on ECBC slows down the amendment of local building by-laws as well as ECBC implementation. The intent of this white paper is to share with Indian decision-makers code enforcement approaches: through code officials, third-party inspectors, or a hybrid approach. Given the limited capacity and

  4. Innovation and Standardization in School Building: A Proposal for the National Code in Italy.

    ERIC Educational Resources Information Center

    Ridolfi, Giuseppe

    This document discusses the University of Florence's experience and concepts as it developed the research to define a proposal for designing a new national school building code. Section 1 examines the current school building code and the Italian Reform Process in Education between 1960 and 2000. Section 2 details and explains the new school…

  5. Revision of seismic design codes corresponding to building damages in the ``5.12'' Wenchuan earthquake

    NASA Astrophysics Data System (ADS)

    Wang, Yayong

    2010-06-01

    A large number of buildings were seriously damaged or collapsed in the “5.12” Wenchuan earthquake. Based on field surveys and studies of damage to different types of buildings, seismic design codes have been updated. This paper briefly summarizes some of the major revisions that have been incorporated into the “Standard for classification of seismic protection of building constructions GB50223-2008” and “Code for Seismic Design of Buildings GB50011-2001.” The definition of seismic fortification class for buildings has been revisited, and as a result, the seismic classifications for schools, hospitals and other buildings that hold large populations such as evacuation shelters and information centers have been upgraded in the GB50223-2008 Code. The main aspects of the revised GB50011-2001 code include: (a) modification of the seismic intensity specified for the Provinces of Sichuan, Shanxi and Gansu; (b) basic conceptual design for retaining walls and building foundations in mountainous areas; (c) regularity of building configuration; (d) integration of masonry structures and pre-cast RC floors; (e) requirements for calculating and detailing stair shafts; and (f) limiting the use of single-bay RC frame structures. Some significant examples of damage in the epicenter areas are provided as a reference in the discussion on the consequences of collapse, the importance of duplicate structural systems, and the integration of RC and masonry structures.

  6. Residential building codes, affordability, and health protection: a risk-tradeoff approach.

    PubMed

    Hammitt, J K; Belsky, E S; Levy, J I; Graham, J D

    1999-12-01

    Residential building codes intended to promote health and safety may produce unintended countervailing risks by adding to the cost of construction. Higher construction costs increase the price of new homes and may increase health and safety risks through "income" and "stock" effects. The income effect arises because households that purchase a new home have less income remaining for spending on other goods that contribute to health and safety. The stock effect arises because suppression of new-home construction leads to slower replacement of less safe housing units. These countervailing risks are not presently considered in code debates. We demonstrate the feasibility of estimating the approximate magnitude of countervailing risks by combining the income effect with three relatively well understood and significant home-health risks. We estimate that a code change that increases the nationwide cost of constructing and maintaining homes by $150 (0.1% of the average cost to build a single-family home) would induce offsetting risks yielding between 2 and 60 premature fatalities or, including morbidity effects, between 20 and 800 lost quality-adjusted life years (both discounted at 3%) each year the code provision remains in effect. To provide a net health benefit, the code change would need to reduce risk by at least this amount. Future research should refine these estimates, incorporate quantitative uncertainty analysis, and apply a full risk-tradeoff approach to real-world case studies of proposed code changes.

  7. Empirical evidence for site coefficients in building code provisions

    USGS Publications Warehouse

    Borcherdt, R.D.

    2002-01-01

    Site-response coefficients, Fa and Fv, used in U.S. building code provisions are based on empirical data for motions up to 0.1 g. For larger motions they are based on theoretical and laboratory results. The Northridge earthquake of 17 January 1994 provided a significant new set of empirical data up to 0.5 g. These data together with recent site characterizations based on shear-wave velocity measurements provide empirical estimates of the site coefficients at base accelerations up to 0.5 g for Site Classes C and D. These empirical estimates of Fa and Fnu; as well as their decrease with increasing base acceleration level are consistent at the 95 percent confidence level with those in present building code provisions, with the exception of estimates for Fa at levels of 0.1 and 0.2 g, which are less than the lower confidence bound by amounts up to 13 percent. The site-coefficient estimates are consistent at the 95 percent confidence level with those of several other investigators for base accelerations greater than 0.3 g. These consistencies and present code procedures indicate that changes in the site coefficients are not warranted. Empirical results for base accelerations greater than 0.2 g confirm the need for both a short- and a mid- or long-period site coefficient to characterize site response for purposes of estimating site-specific design spectra.

  8. Active Fault Near-Source Zones Within and Bordering the State of California for the 1997 Uniform Building Code

    USGS Publications Warehouse

    Petersen, M.D.; Toppozada, Tousson R.; Cao, T.; Cramer, C.H.; Reichle, M.S.; Bryant, W.A.

    2000-01-01

    The fault sources in the Project 97 probabilistic seismic hazard maps for the state of California were used to construct maps for defining near-source seismic coefficients, Na and Nv, incorporated in the 1997 Uniform Building Code (ICBO 1997). The near-source factors are based on the distance from a known active fault that is classified as either Type A or Type B. To determine the near-source factor, four pieces of geologic information are required: (1) recognizing a fault and determining whether or not the fault has been active during the Holocene, (2) identifying the location of the fault at or beneath the ground surface, (3) estimating the slip rate of the fault, and (4) estimating the maximum earthquake magnitude for each fault segment. This paper describes the information used to produce the fault classifications and distances.

  9. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  10. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  11. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  12. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  13. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  14. Near Zone: Basic scattering code user's manual with space station applications

    NASA Technical Reports Server (NTRS)

    Marhefka, R. J.; Silvestro, J. W.

    1989-01-01

    The Electromagnetic Code - Basic Scattering Code, Version 3, is a user oriented computer code to analyze near and far zone patterns of antennas in the presence of scattering structures, to provide coupling between antennas in a complex environment, and to determine radiation hazard calculations at UHF and above. The analysis is based on uniform asymptotic techniques formulated in terms of the Uniform Geometrical Theory of Diffraction (UTD). Complicated structures can be simulated by arbitrarily oriented flat plates and an infinite ground plane that can be perfectly conducting or dielectric. Also, perfectly conducting finite elliptic cylinder, elliptic cone frustum sections, and finite composite ellipsoids can be used to model the superstructure of a ship, the body of a truck, and airplane, a satellite, etc. This manual gives special consideration to space station modeling applications. This is a user manual designed to give an overall view of the operation of the computer code, to instruct a user in how to model structures, and to show the validity of the code by comparing various computed results against measured and alternative calculations such as method of moments whenever available.

  15. Environmental performance of green building code and certification systems.

    PubMed

    Suh, Sangwon; Tomar, Shivira; Leighton, Matthew; Kneifel, Joshua

    2014-01-01

    We examined the potential life-cycle environmental impact reduction of three green building code and certification (GBCC) systems: LEED, ASHRAE 189.1, and IgCC. A recently completed whole-building life cycle assessment (LCA) database of NIST was applied to a prototype building model specification by NREL. TRACI 2.0 of EPA was used for life cycle impact assessment (LCIA). The results showed that the baseline building model generates about 18 thousand metric tons CO2-equiv. of greenhouse gases (GHGs) and consumes 6 terajoule (TJ) of primary energy and 328 million liter of water over its life-cycle. Overall, GBCC-compliant building models generated 0% to 25% less environmental impacts than the baseline case (average 14% reduction). The largest reductions were associated with acidification (25%), human health-respiratory (24%), and global warming (GW) (22%), while no reductions were observed for ozone layer depletion (OD) and land use (LU). The performances of the three GBCC-compliant building models measured in life-cycle impact reduction were comparable. A sensitivity analysis showed that the comparative results were reasonably robust, although some results were relatively sensitive to the behavioral parameters, including employee transportation and purchased electricity during the occupancy phase (average sensitivity coefficients 0.26-0.29).

  16. Probabilistic seismic hazard zonation for the Cuban building code update

    NASA Astrophysics Data System (ADS)

    Garcia, J.; Llanes-Buron, C.

    2013-05-01

    A probabilistic seismic hazard assessment has been performed in response to a revision and update of the Cuban building code (NC-46-99) for earthquake-resistant building construction. The hazard assessment have been done according to the standard probabilistic approach (Cornell, 1968) and importing the procedures adopted by other nations dealing with the problem of revising and updating theirs national building codes. Problems of earthquake catalogue treatment, attenuation of peak and spectral ground acceleration, as well as seismic source definition have been rigorously analyzed and a logic-tree approach was used to represent the inevitable uncertainties encountered through the whole seismic hazard estimation process. The seismic zonation proposed here, is formed by a map where it is reflected the behaviour of the spectral acceleration values for short (0.2 seconds) and large (1.0 seconds) periods on rock conditions with a 1642 -year return period, which being considered as maximum credible earthquake (ASCE 07-05). In addition, other three design levels are proposed (severe earthquake: with a 808 -year return period, ordinary earthquake: with a 475 -year return period and minimum earthquake: with a 225 -year return period). The seismic zonation proposed here fulfils the international standards (IBC-ICC) as well as the world tendencies in this thematic.

  17. Achieving a Healthy Zoning Policy in Baltimore: Results of a Health Impact Assessment of the TransForm Baltimore Zoning Code Rewrite

    PubMed Central

    Greiner, Amelia; Fichtenberg, Caroline M.; Feingold, Beth J.; Ellen, Jonathan M.; Jennings, Jacky M.

    2013-01-01

    Objectives The social determinants of health (SDH) include factors apart from genes and biology that affect population health. Zoning is an urban planning tool that influences neighborhood built environments. We describe the methods and results of a health impact assessment (HIA) of a rezoning effort in Baltimore, Maryland, called TransForm Baltimore. We highlight findings specific to physical activity, violent crime, and obesity. Methods We conducted a multistage HIA of TransForm Baltimore using HIA practice guidelines. Key informant interviews identified focus areas for the quantitative assessment. A literature review and a zoning code analysis evaluated potential impacts on neighborhood factors including physical activity, violent crime, and obesity. We estimated potential impacts in high- and low-poverty neighborhoods. The findings resulted in recommendations to improve the health-promoting potential of TransForm Baltimore. Results Mixed-use and transit-oriented development were key goals of TransForm Baltimore. Health impacts identified by stakeholders included walkability and healthy communities. For Baltimore residents, we estimated that (1) the percentage of people living in districts allowing mixed-use and off-premise alcohol outlets would nearly triple, (2) 18% would live in transit-oriented development zones, and (3) all residents would live in districts with new lighting and landscaping guidelines. Limiting the concentration of off-premise alcohol outlets represented an opportunity to address health promotion. Conclusions Changes to Baltimore's zoning code could improve population health including decreasing violent crime. HIAs are an important platform for applying SDH to public health practice. This HIA specifically linked municipal zoning policy with promoting healthier neighborhoods. PMID:24179284

  18. Effect of URM infills on seismic vulnerability of Indian code designed RC frame buildings

    NASA Astrophysics Data System (ADS)

    Haldar, Putul; Singh, Yogendra; Paul, D. K.

    2012-03-01

    Unreinforced Masonry (URM) is the most common partitioning material in framed buildings in India and many other countries. Although it is well-known that under lateral loading the behavior and modes of failure of the frame buildings change significantly due to infill-frame interaction, the general design practice is to treat infills as nonstructural elements and their stiffness, strength and interaction with the frame is often ignored, primarily because of difficulties in simulation and lack of modeling guidelines in design codes. The Indian Standard, like many other national codes, does not provide explicit insight into the anticipated performance and associated vulnerability of infilled frames. This paper presents an analytical study on the seismic performance and fragility analysis of Indian code-designed RC frame buildings with and without URM infills. Infills are modeled as diagonal struts as per ASCE 41 guidelines and various modes of failure are considered. HAZUS methodology along with nonlinear static analysis is used to compare the seismic vulnerability of bare and infilled frames. The comparative study suggests that URM infills result in a significant increase in the seismic vulnerability of RC frames and their effect needs to be properly incorporated in design codes.

  19. Capturing Energy-Saving Opportunities: Improving Building Efficiency in Rajasthan through Energy Code Implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Qing; Yu, Sha; Evans, Meredydd

    2016-05-01

    India adopted the Energy Conservation Building Code (ECBC) in 2007. Rajasthan is the first state to make ECBC mandatory at the state level. In collaboration with Malaviya National Institute of Technology (MNIT) Jaipur, Pacific Northwest National Laboratory (PNNL) has been working with Rajasthan to facilitate the implementation of ECBC. This report summarizes milestones made in Rajasthan and PNNL's contribution in institutional set-ups, capacity building, compliance enforcement and pilot building construction.

  20. 76 FR 13101 - Building Energy Codes Program: Presenting and Receiving Comments to DOE Proposed Changes to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-10

    .... The IgCC is intended to provide a green model building code provisions for new and existing commercial... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket No. EERE-2011-BT-BC-0009] Building Energy Codes Program: Presenting and Receiving Comments to DOE Proposed Changes to the International Green Construction...

  1. 50 CFR Table 8 to Part 679 - Harvest Zone Codes for Use With Vessel Activity Reports

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 13 2014-10-01 2014-10-01 false Harvest Zone Codes for Use With Vessel Activity Reports 8 Table 8 to Part 679 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) FISHERIES OF THE EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 679, Table 8...

  2. Using MERRA, AMIP II, CMIP5 Outputs to Assess Actual and Potential Building Climate Zone Change and Variability From the Last 30 Years Through 2100

    NASA Astrophysics Data System (ADS)

    Stackhouse, P. W.; Westberg, D. J.; Hoell, J. M., Jr.; Chandler, W.; Zhang, T.

    2014-12-01

    In the US, residential and commercial building infrastructure combined consumes about 40% of total energy usage and emits about 39% of total CO2emission (DOE/EIA "Annual Energy Outlook 2013"). Thus, increasing the energy efficiency of buildings is paramount to reducing energy costs and emissions. Building codes, as used by local and state enforcement entities are typically tied to the dominant climate within an enforcement jurisdiction classified according to various climate zones. These climates zones are based upon a 30-year average of local surface observations and are developed by DOE and ASHRAE (formerly known as the American Society of Hearting, Refrigeration and Air-Conditioning Engineers). A significant shortcoming of the methodology used in constructing such maps is the use of surface observations (located mainly near airports) that are unequally distributed and frequently have periods of missing data that need to be filled by various approximation schemes. This paper demonstrates the usefulness of using NASA's Modern Era Retrospective-analysis for Research and Applications (MERRA) atmospheric data assimilation to derive the ASHRAE climate zone maps and then using MERRA to define the last 30 years of variability in climate zones. These results show that there is a statistically significant increase in the area covered by warmer climate zones and some tendency for a reduction of area in colder climate zones that require longer time series to confirm. Using the uncertainties of the basic surface temperature and precipitation parameters from MERRA as determined by comparison to surface measurements, we first compare patterns and variability of ASHRAE climate zones from MERRA relative to present day climate model runs from AMIP simulations to establish baseline sensitivity. Based upon these results, we assess the variability of the ASHRAE climate zones according to CMIP runs through 2100 using an ensemble analysis that classifies model output changes by

  3. Applications of the seismic hazard model of Italy: from a new building code to the L'Aquila trial against seismologists

    NASA Astrophysics Data System (ADS)

    Meletti, C.

    2013-05-01

    In 2003, a large national project fur updating the seismic hazard map and the seismic zoning in Italy started, according to the rules fixed by an Ordinance by Italian Prime Minister. New input elements for probabilistic seismic hazard assessment were compiled: the earthquake catalogue, the seismogenic zonation, the catalogue completeness, a set of new attenuation relationships. The map of expected PGA on rock soil condition with 10% probability of exceedance is the new reference seismic hazard map for Italy (http://zonesismiche.mi.ingv.it). In the following, further 9 probabilities of exceedance and the uniform hazard spectra up to 2 seconds together with the disaggregation of the PGA was also released. A comprehensive seismic hazard model that fully describes the seismic hazard in Italy was then available, accessible by a webGis application (http://esse1-gis.mi.ingv.it/en.php). The detailed information make possible to change the approach for evaluating the proper seismic action for designing: from a zone-dependent approach (in Italy there were 4 seismic zones, each one with a single design spectrum) to a site-dependent approach: the design spectrum is now defined at each site of a grid of about 11000 points covering the whole national territory. The new building code becomes mandatory only after the 6 April 2009 L'Aquila earthquake, the first strong event in Italy after the release of the seismic hazard map. The large number of recordings and the values of the experienced accelerations suggested the comparisons between the recorded spectra and spectra defined in the seismic codes Even if such comparisons could be robust only after several consecutive 50-year periods of observation and in a probabilistic approach it is not a single observation that can validate or not the hazard estimate, some of the comparisons that can be undertaken between the observed ground motions and the hazard model used for the seismic code have been performed and have shown that the

  4. Recommendations on Implementing the Energy Conservation Building Code in Rajasthan, India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Makela, Eric J.; Evans, Meredydd

    India launched the Energy Conservation Building Code (ECBC) in 2007 and Indian Bureau of Energy Efficiency (BEE) recently indicated that it would move to mandatory implementation in the 12th Five-Year Plan. The State of Rajasthan adopted ECBC with minor modifications; the new regulation is known as the Energy Conservation Building Directives – Rajasthan 2011 (ECBD-R). It became mandatory in Rajasthan on September 28, 2011. This report provides recommendations on an ECBD-R enforcement roadmap for the State of Rajasthan.

  5. Energy Cost Impact of Non-Residential Energy Code Requirements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jian; Hart, Philip R.; Rosenberg, Michael I.

    2016-08-22

    The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of themore » probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.« less

  6. The international implications of national and local coordination on building energy codes: Case studies in six cities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Meredydd; Yu, Sha; Staniszewski, Aaron

    Building energy efficiency is an important strategy for reducing greenhouse gas emissions globally. In fact, 55 countries have included building energy efficiency in their Nationally Determined Contributions (NDCs) under the Paris Agreement. This research uses building energy code implementation in six cities across different continents as case studies to assess what it may take for countries to implement the ambitions of their energy efficiency goals. Specifically, we look at the cases of Bogota, Colombia; Da Nang, Vietnam; Eskisehir, Turkey; Mexico City, Mexico; Rajkot, India; and Tshwane, South Africa, all of which are “deep dive” cities under the Sustainable Energy formore » All's Building Efficiency Accelerator. The research focuses on understanding the baseline with existing gaps in implementation and coordination. The methodology used a combination of surveys on code status and interviews with stakeholders at the local and national level, as well as review of published documents. We looked at code development, implementation, and evaluation. The cities are all working to improve implementation, however, the challenges they currently face include gaps in resources, capacity, tools, and institutions to check for compliance. Better coordination between national and local governments could help improve implementation, but that coordination is not yet well established. For example, all six of the cities reported that there was little to no involvement of local stakeholders in development of the national code; only one city reported that it had access to national funding to support code implementation. More robust coordination could better link cities with capacity building and funding for compliance, and ensure that the code reflects local priorities. By understanding gaps in implementation, it can also help in designing more targeted interventions to scale up energy savings.« less

  7. The international implications of national and local coordination on building energy codes: Case studies in six cities

    DOE PAGES

    Evans, Meredydd; Yu, Sha; Staniszewski, Aaron; ...

    2018-04-17

    Building energy efficiency is an important strategy for reducing greenhouse gas emissions globally. In fact, 55 countries have included building energy efficiency in their Nationally Determined Contributions (NDCs) under the Paris Agreement. This research uses building energy code implementation in six cities across different continents as case studies to assess what it may take for countries to implement the ambitions of their energy efficiency goals. Specifically, we look at the cases of Bogota, Colombia; Da Nang, Vietnam; Eskisehir, Turkey; Mexico City, Mexico; Rajkot, India; and Tshwane, South Africa, all of which are “deep dive” cities under the Sustainable Energy formore » All's Building Efficiency Accelerator. The research focuses on understanding the baseline with existing gaps in implementation and coordination. The methodology used a combination of surveys on code status and interviews with stakeholders at the local and national level, as well as review of published documents. We looked at code development, implementation, and evaluation. The cities are all working to improve implementation, however, the challenges they currently face include gaps in resources, capacity, tools, and institutions to check for compliance. Better coordination between national and local governments could help improve implementation, but that coordination is not yet well established. For example, all six of the cities reported that there was little to no involvement of local stakeholders in development of the national code; only one city reported that it had access to national funding to support code implementation. More robust coordination could better link cities with capacity building and funding for compliance, and ensure that the code reflects local priorities. By understanding gaps in implementation, it can also help in designing more targeted interventions to scale up energy savings.« less

  8. Deregulation of the Building Code and the Norwegian Approach to Regulation of Accessibility in the Built Environment.

    PubMed

    Lyngstad, Pål

    2016-01-01

    Deregulation is on the political agenda in the European countries. The Norwegian building code related to universal design and accessibility is challenged. To meet this, the Norwegian Building Authority have chosen to examine established truths and are basing their revised code on scientific research and field tests. But will this knowledge-based deregulation comply within the framework of the anti-discrimination act and, and if not: who suffers and to what extent?

  9. Learning by Doing: Teaching Decision Making through Building a Code of Ethics.

    ERIC Educational Resources Information Center

    Hawthorne, Mark D.

    2001-01-01

    Notes that applying abstract ethical principles to the practical business of building a code of applied ethics for a technical communication department teaches students that they share certain unarticulated or unconscious values that they can translate into ethical principles. Suggests that combining abstract theory with practical policy writing…

  10. Energy and Environment Guide to Action - Chapter 4.3: Building Codes for Energy Efficiency

    EPA Pesticide Factsheets

    Provides guidance and recommendations for establishing, implementing, and evaluating state building codes for energy efficiency, which improve energy efficiency in new construction and major renovations. State success stories are included for reference.

  11. Light curves for bump Cepheids computed with a dynamically zoned pulsation code

    NASA Technical Reports Server (NTRS)

    Adams, T. F.; Castor, J. I.; Davis, C. G.

    1980-01-01

    The dynamically zoned pulsation code developed by Castor, Davis, and Davison was used to recalculate the Goddard model and to calculate three other Cepheid models with the same period (9.8 days). This family of models shows how the bumps and other features of the light and velocity curves change as the mass is varied at constant period. The use of a code that is capable of producing reliable light curves demonstrates that the light and velocity curves for 9.8 day Cepheid models with standard homogeneous compositions do not show bumps like those that are observed unless the mass is significantly lower than the 'evolutionary mass.' The light and velocity curves for the Goddard model presented here are similar to those computed independently by Fischel, Sparks, and Karp. They should be useful as standards for future investigators.

  12. Assessment of codes, by-laws and regulations relating to air wells in building design

    NASA Astrophysics Data System (ADS)

    Fadzil, Sharifah Fairuz Syed; Karamazaman, Nazli

    2017-10-01

    Codes and by-laws concerning air well design (for buildings and lavatories) in Malaysia has been established in the Malaysian Uniform Building By-Laws UBBL number 40 (1) and (2) since the 1980s. Wells are there to fulfill the ventilation and daylighting requirements. The minimum well area according to building storey height are compared between UBBL and the Singapore's well requirements from the Building Construction Authority BCA. A visual and graphical representation (with schematics building and well diagrams drawn to scale) of the minimum well sizes and dimensions is given. It can be seen that if the minimum requirement of well size is used for buildings above 8 storeys high, a thin well resulted which is not proportionate to the building height. A proposed dimension is graphed and given to be used in the UBBL which translated to graphics (3 dimensional buildings drawn to scale) created a much better well proportion.

  13. Impacts of building geometry modeling methods on the simulation results of urban building energy models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yixing; Hong, Tianzhen

    We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while

  14. Impacts of building geometry modeling methods on the simulation results of urban building energy models

    DOE PAGES

    Chen, Yixing; Hong, Tianzhen

    2018-02-20

    We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while

  15. Automatic building information model query generation

    DOE PAGES

    Jiang, Yufei; Yu, Nan; Ming, Jiang; ...

    2015-12-01

    Energy efficient building design and construction calls for extensive collaboration between different subfields of the Architecture, Engineering and Construction (AEC) community. Performing building design and construction engineering raises challenges on data integration and software interoperability. Using Building Information Modeling (BIM) data hub to host and integrate building models is a promising solution to address those challenges, which can ease building design information management. However, the partial model query mechanism of current BIM data hub collaboration model has several limitations, which prevents designers and engineers to take advantage of BIM. To address this problem, we propose a general and effective approachmore » to generate query code based on a Model View Definition (MVD). This approach is demonstrated through a software prototype called QueryGenerator. In conclusion, by demonstrating a case study using multi-zone air flow analysis, we show how our approach and tool can help domain experts to use BIM to drive building design with less labour and lower overhead cost.« less

  16. Automatic building information model query generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Yufei; Yu, Nan; Ming, Jiang

    Energy efficient building design and construction calls for extensive collaboration between different subfields of the Architecture, Engineering and Construction (AEC) community. Performing building design and construction engineering raises challenges on data integration and software interoperability. Using Building Information Modeling (BIM) data hub to host and integrate building models is a promising solution to address those challenges, which can ease building design information management. However, the partial model query mechanism of current BIM data hub collaboration model has several limitations, which prevents designers and engineers to take advantage of BIM. To address this problem, we propose a general and effective approachmore » to generate query code based on a Model View Definition (MVD). This approach is demonstrated through a software prototype called QueryGenerator. In conclusion, by demonstrating a case study using multi-zone air flow analysis, we show how our approach and tool can help domain experts to use BIM to drive building design with less labour and lower overhead cost.« less

  17. The evolution of a dead zone in a circumplanetary disk

    NASA Astrophysics Data System (ADS)

    Chen, Cheng; Martin, Rebecca; Zhu, Zhaohuan

    2018-01-01

    Studying the evolution of a circumplanetary disk can help us to understand the formation of Jupiter and the four Galilean satellites. With the grid-based hydrodynamic code, FARGO3D, we simulate the evolution of a circumplanetary disk with a dead zone, a region of low turbulence. Tidal torques from the sun constrain the size of the circumplanetary disk to about 0.4 R_H. The dead zone provides a cold environment for icy satellite formation. However, as material builds up there, the temperature of the dead zone may reach the critical temperature required for the magnetorotational instability to drive turbulence. Part of the dead zone accretes on to the planet in an accretion outburst. We explore possible disk parameters that provide a suitable environment for satellite formation.

  18. User's Guide and Download for IECCU- Indoor Environmental Concentrations in Buildings with Conditioned and Unconditioned Zones

    EPA Pesticide Factsheets

    This program serves two purposes: (1) as a general-purpose indoor exposure model in buildings with multiple zones, multiple chemicals and multiple sources and sinks, and (2) as a special-purpose concentration model

  19. Codes That Support Smart Growth Development

    EPA Pesticide Factsheets

    Provides examples of local zoning codes that support smart growth development, categorized by: unified development code, form-based code, transit-oriented development, design guidelines, street design standards, and zoning overlay.

  20. Reducing EnergyPlus Run Time For Code Compliance Tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Athalye, Rahul A.; Gowri, Krishnan; Schultz, Robert W.

    2014-09-12

    Integration of the EnergyPlus ™ simulation engine into performance-based code compliance software raises a concern about simulation run time, which impacts timely feedback of compliance results to the user. EnergyPlus annual simulations for proposed and code baseline building models, and mechanical equipment sizing result in simulation run times beyond acceptable limits. This paper presents a study that compares the results of a shortened simulation time period using 4 weeks of hourly weather data (one per quarter), to an annual simulation using full 52 weeks of hourly weather data. Three representative building types based on DOE Prototype Building Models and threemore » climate zones were used for determining the validity of using a shortened simulation run period. Further sensitivity analysis and run time comparisons were made to evaluate the robustness and run time savings of using this approach. The results of this analysis show that the shortened simulation run period provides compliance index calculations within 1% of those predicted using annual simulation results, and typically saves about 75% of simulation run time.« less

  1. A comparison of IBC with 1997 UBC for modal response spectrum analysis in standard-occupancy buildings

    NASA Astrophysics Data System (ADS)

    Nahhas, Tariq M.

    2011-03-01

    This paper presents a comparison of the seismic forces generated from a Modal Response Spectrum Analysis (MRSA) by applying the provisions of two building codes, the 1997 Uniform Building Code (UBC) and the 2000-2009 International Building Code (IBC), to the most common ordinary residential buildings of standard occupancy. Considering IBC as the state of the art benchmark code, the primary concern is the safety of buildings designed using the UBC as compared to those designed using the IBC. A sample of four buildings with different layouts and heights was used for this comparison. Each of these buildings was assumed to be located at four different geographical sample locations arbitrarily selected to represent various earthquake zones on a seismic map of the USA, and was subjected to code-compliant response spectrum analyses for all sample locations and for five different soil types at each location. Response spectrum analysis was performed using the ETABS software package. For all the cases investigated, the UBC was found to be significantly more conservative than the IBC. The UBC design response spectra have higher spectral accelerations, and as a result, the response spectrum analysis provided a much higher base shear and moment in the structural members as compared to the IBC. The conclusion is that ordinary office and residential buildings designed using UBC 1997 are considered to be overdesigned, and therefore they are quite safe even according to the IBC provisions.

  2. 78 FR 47677 - DOE Activities and Methodology for Assessing Compliance With Building Energy Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-06

    ... construction. Post- construction evaluations were implemented in one study in an effort to reduce these costs... these pilot studies have led to a number of recommendations and potential changes to the DOE methodology... fundamental assumptions and approaches to measuring compliance with building energy codes. This notice...

  3. Fundamental period of Italian reinforced concrete buildings: comparison between numerical, experimental and Italian code simplified values

    NASA Astrophysics Data System (ADS)

    Ditommaso, Rocco; Carlo Ponzo, Felice; Auletta, Gianluca; Iacovino, Chiara; Nigro, Antonella

    2015-04-01

    Aim of this study is a comparison among the fundamental period of reinforced concrete buildings evaluated using the simplified approach proposed by the Italian Seismic code (NTC 2008), numerical models and real values retrieved from an experimental campaign performed on several buildings located in Basilicata region (Italy). With the intention of proposing simplified relationships to evaluate the fundamental period of reinforced concrete buildings, scientists and engineers performed several numerical and experimental campaigns, on different structures all around the world, to calibrate different kind of formulas. Most of formulas retrieved from both numerical and experimental analyses provides vibration periods smaller than those suggested by the Italian seismic code. However, it is well known that the fundamental period of a structure play a key role in the correct evaluation of the spectral acceleration for seismic static analyses. Generally, simplified approaches impose the use of safety factors greater than those related to in depth nonlinear analyses with the aim to cover possible unexpected uncertainties. Using the simplified formula proposed by the Italian seismic code the fundamental period is quite higher than fundamental periods experimentally evaluated on real structures, with the consequence that the spectral acceleration adopted in the seismic static analysis may be significantly different than real spectral acceleration. This approach could produces a decreasing in safety factors obtained using linear and nonlinear seismic static analyses. Finally, the authors suggest a possible update of the Italian seismic code formula for the simplified estimation of the fundamental period of vibration of existing RC buildings, taking into account both elastic and inelastic structural behaviour and the interaction between structural and non-structural elements. Acknowledgements This study was partially funded by the Italian Civil Protection Department within the

  4. The effects of climate change on heating energy consumption of office buildings in different climate zones in China

    NASA Astrophysics Data System (ADS)

    Meng, Fanchao; Li, Mingcai; Cao, Jingfu; Li, Ji; Xiong, Mingming; Feng, Xiaomei; Ren, Guoyu

    2017-06-01

    Climate plays an important role in heating energy consumption owing to the direct relationship between space heating and changes in meteorological conditions. To quantify the impact, the Transient System Simulation Program software was used to simulate the heating loads of office buildings in Harbin, Tianjin, and Shanghai, representing three major climate zones (i.e., severe cold, cold, and hot summer and cold winter climate zones) in China during 1961-2010. Stepwise multiple linear regression was performed to determine the key climatic parameters influencing heating energy consumption. The results showed that dry bulb temperature (DBT) is the dominant climatic parameter affecting building heating loads in all three climate zones across China during the heating period at daily, monthly, and yearly scales (R 2 ≥ 0.86). With the continuous warming climate in winter over the past 50 years, heating loads decreased by 14.2, 7.2, and 7.1 W/m2 in Harbin, Tianjin, and Shanghai, respectively, indicating that the decreasing rate is more apparent in severe cold climate zone. When the DBT increases by 1 °C, the heating loads decrease by 253.1 W/m2 in Harbin, 177.2 W/m2 in Tianjin, and 126.4 W/m2 in Shanghai. These results suggest that the heating energy consumption can be well predicted by the regression models at different temporal scales in different climate conditions owing to the high determination coefficients. In addition, a greater decrease in heating energy consumption in northern severe cold and cold climate zones may efficiently promote the energy saving in these areas with high energy consumption for heating. Particularly, the likely future increase in temperatures should be considered in improving building energy efficiency.

  5. Updates to building-code maps for the 2015 NEHRP recommended seismic provisions

    USGS Publications Warehouse

    Luco, Nicolas; Bachman, Robert; Crouse, C.B; Harris, James R.; Hooper, John D.; Kircher, Charles A.; Caldwell, Phillp; Rukstales, Kenneth S.

    2015-01-01

    With the 2014 update of the U.S. Geological Survey (USGS) National Seismic Hazard Model (NSHM) as a basis, the Building Seismic Safety Council (BSSC) has updated the earthquake ground motion maps in the National Earthquake Hazards Reduction Program (NEHRP) Recommended Seismic Provisions for New Buildings and Other Structures, with partial funding from the Federal Emergency Management Agency. Anticipated adoption of the updated maps into the American Society of Civil Engineers Minimum Design Loads for Building and Other Structures and the International Building and Residential Codes is underway. Relative to the ground motions in the prior edition of each of these documents, most of the updated values are within a ±20% change. The larger changes are, in most cases, due to the USGS NSHM updates, reasons for which are given in companion publications. In some cases, the larger changes are partly due to a BSSC update of the slope of the fragility curve that is used to calculate the risk-targeted ground motions, and/or the introduction by BSSC of a quantitative definition of “active faults” used to calculate deterministic ground motions.

  6. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... below. (1) Model Building Codes—(i) The BOCA National Building Code, 1993 Edition, The BOCA National..., Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood... number 2 (Chapter 7) of the Building Code, but including the Appendices of the Code. Available from...

  7. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... below. (1) Model Building Codes—(i) The BOCA National Building Code, 1993 Edition, The BOCA National..., Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood... number 2 (Chapter 7) of the Building Code, but including the Appendices of the Code. Available from...

  8. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... below. (1) Model Building Codes—(i) The BOCA National Building Code, 1993 Edition, The BOCA National..., Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood... number 2 (Chapter 7) of the Building Code, but including the Appendices of the Code. Available from...

  9. 78 FR 18321 - International Code Council: The Update Process for the International Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... for Residential Construction in High Wind Regions. ICC 700: National Green Building Standard The..., coordinated, and necessary to regulate the built environment. Federal agencies frequently use these codes and... International Codes and Standards consist of the following: ICC Codes International Building Code. International...

  10. 75 FR 19944 - International Code Council: The Update Process for the International Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-16

    ... for Residential Construction in High Wind Areas. ICC 700: National Green Building Standard. The... Codes and Standards that are comprehensive, coordinated, and necessary to regulate the built environment... International Codes and Standards consist of the following: ICC Codes International Building Code. International...

  11. Multidisciplinary co-operation in building design according to urbanistic zoning and seismic microzonation

    NASA Astrophysics Data System (ADS)

    Bostenaru Dan, M.

    2005-05-01

    Research and practice in seismology and urban planning interfere concerning the impact of earthquakes on urban areas. The roles of sub-area wide or typological divisions of the town were investigated with the methodology of regression, regarding their contribution to urban earthquake risk management. The inductive data set comprised recovery, preparedness, mitigation and resilience planning. All timely constituted planning types are refound today as layers, as the zoning results are used by differently backgrounded actors: local authorities, civil protection, urban planners, civil engineers. In resilience planning, the urban system is complexly theoretised, then integratedly approached. The steady restructuring process of the urban organism is evident in a dynamic analysis. Although expressed materially, the "urban-frame" is realised spiritually, space adaptation being also social. A retrospective investigation of the role of resilient individual buildings within the urban system of Bucharest, Romania, was undertaken, in order to learn systemic lessons considering the street, an educational environment. (In)formation in the study and decision making process stay in a reciprocal relationship, both being obliged in the (in)formation of the public opinion. For a complete view on resilience, both zoning types, seismic and urbanistic, must be considered and through their superposition new sub-area wide divisions of the town appear, making recommendations according to the vulnerability of the building type.

  12. Comparative Study on Code-based Linear Evaluation of an Existing RC Building Damaged during 1998 Adana-Ceyhan Earthquake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toprak, A. Emre; Guelay, F. Guelten; Ruge, Peter

    2008-07-08

    Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performedmore » on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 mx7.80 m = 127.90 m{sup 2} with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is

  13. Comparative Study on Code-based Linear Evaluation of an Existing RC Building Damaged during 1998 Adana-Ceyhan Earthquake

    NASA Astrophysics Data System (ADS)

    Toprak, A. Emre; Gülay, F. Gülten; Ruge, Peter

    2008-07-01

    Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 m×7.80 m = 127.90 m2 with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher

  14. Lessons learned from new construction utility demand side management programs and their implications for implementing building energy codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wise, B.K.; Hughes, K.R.; Danko, S.L.

    1994-07-01

    This report was prepared for the US Department of Energy (DOE) Office of Codes and Standards by the Pacific Northwest Laboratory (PNL) through its Building Energy Standards Program (BESP). The purpose of this task was to identify demand-side management (DSM) strategies for new construction that utilities have adopted or developed to promote energy-efficient design and construction. PNL conducted a survey of utilities and used the information gathered to extrapolate lessons learned and to identify evolving trends in utility new-construction DSM programs. The ultimate goal of the task is to identify opportunities where states might work collaboratively with utilities to promotemore » the adoption, implementation, and enforcement of energy-efficient building energy codes.« less

  15. Effects of internal gain assumptions in building energy calculations

    NASA Astrophysics Data System (ADS)

    Christensen, C.; Perkins, R.

    1981-01-01

    The utilization of direct solar gains in buildings can be affected by operating profiles, such as schedules for internal gains, thermostat controls, and ventilation rates. Building energy analysis methods use various assumptions about these profiles. The effects of typical internal gain assumptions in energy calculations are described. Heating and cooling loads from simulations using the DOE 2.1 computer code are compared for various internal gain inputs: typical hourly profiles, constant average profiles, and zero gain profiles. Prototype single-family-detached and multifamily-attached residential units are studied with various levels of insulation and infiltration. Small detached commercial buildings and attached zones in large commercial buildings are studied with various levels of internal gains. The results indicate that calculations of annual heating and cooling loads are sensitive to internal gains, but in most cases are relatively insensitive to hourly variations in internal gains.

  16. Seismic Safety Of Simple Masonry Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guadagnuolo, Mariateresa; Faella, Giuseppe

    2008-07-08

    Several masonry buildings comply with the rules for simple buildings provided by seismic codes. For these buildings explicit safety verifications are not compulsory if specific code rules are fulfilled. In fact it is assumed that their fulfilment ensures a suitable seismic behaviour of buildings and thus adequate safety under earthquakes. Italian and European seismic codes differ in the requirements for simple masonry buildings, mostly concerning the building typology, the building geometry and the acceleration at site. Obviously, a wide percentage of buildings assumed simple by codes should satisfy the numerical safety verification, so that no confusion and uncertainty have tomore » be given rise to designers who must use the codes. This paper aims at evaluating the seismic response of some simple unreinforced masonry buildings that comply with the provisions of the new Italian seismic code. Two-story buildings, having different geometry, are analysed and results from nonlinear static analyses performed by varying the acceleration at site are presented and discussed. Indications on the congruence between code rules and results of numerical analyses performed according to the code itself are supplied and, in this context, the obtained result can provide a contribution for improving the seismic code requirements.« less

  17. VS30 – A site-characterization parameter for use in building Codes, simplified earthquake resistant design, GMPEs, and ShakeMaps

    USGS Publications Warehouse

    Borcherdt, Roger D.

    2012-01-01

    VS30, defined as the average seismic shear-wave velocity from the surface to a depth of 30 meters, has found wide-spread use as a parameter to characterize site response for simplified earthquake resistant design as implemented in building codes worldwide. VS30 , as initially introduced by the author for the US 1994 NEHRP Building Code, provides unambiguous definitions of site classes and site coefficients for site-dependent response spectra based on correlations derived from extensive borehole logging and comparative ground-motion measurement programs in California. Subsequent use of VS30 for development of strong ground motion prediction equations (GMPEs) and measurement of extensive sets of VS borehole data have confirmed the previous empirical correlations and established correlations of SVS30 with VSZ at other depths. These correlations provide closed form expressions to predict S30 V at a large number of additional sites and further justify S30 V as a parameter to characterize site response for simplified building codes, GMPEs, ShakeMap, and seismic hazard mapping.

  18. A simplified building airflow model for agent concentration prediction.

    PubMed

    Jacques, David R; Smith, David A

    2010-11-01

    A simplified building airflow model is presented that can be used to predict the spread of a contaminant agent from a chemical or biological attack. If the dominant means of agent transport throughout the building is an air-handling system operating at steady-state, a linear time-invariant (LTI) model can be constructed to predict the concentration in any room of the building as a result of either an internal or external release. While the model does not capture weather-driven and other temperature-driven effects, it is suitable for concentration predictions under average daily conditions. The model is easily constructed using information that should be accessible to a building manager, supplemented with assumptions based on building codes and standard air-handling system design practices. The results of the model are compared with a popular multi-zone model for a simple building and are demonstrated for building examples containing one or more air-handling systems. The model can be used for rapid concentration prediction to support low-cost placement strategies for chemical and biological detection sensors.

  19. Comparison of Building Energy Modeling Programs: Building Loads

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Dandan; Hong, Tianzhen; Yan, Da

    This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In themore » fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared

  20. Building a Subduction Zone Observatory

    USGS Publications Warehouse

    Gomberg, Joan S.; Bodin, Paul; Bourgeois, Jody; Cashman, Susan; Cowan, Darrel; Creager, Kenneth C.; Crowell, Brendan; Duvall, Alison; Frankel, Arthur; González, Frank I.; Houston, Heidi; Johnson, Paul; Kelsey, Harvey; Miller, Una; Roland, Emily C.; Schmidt, David; Staisch, Lydia; Vidale, John; Wilcock, William; Wirth, Erin

    2016-01-01

    Subduction zones contain many of Earth’s most remarkable geologic structures, from the deepest oceanic trenches to glacier-covered mountains and steaming volcanoes. These environments formed through spectacular events: Nature’s largest earthquakes, tsunamis, and volcanic eruptions are born here.

  1. 24 CFR 200.926c - Model code provisions for use in partially accepted code jurisdictions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... jurisdictions. If a lender or other interested party is notified that a State or local building code has been... in accordance with the applicable State or local building code, plus those additional requirements... 24 Housing and Urban Development 2 2014-04-01 2014-04-01 false Model code provisions for use in...

  2. 24 CFR 200.926c - Model code provisions for use in partially accepted code jurisdictions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... jurisdictions. If a lender or other interested party is notified that a State or local building code has been... in accordance with the applicable State or local building code, plus those additional requirements... 24 Housing and Urban Development 2 2013-04-01 2013-04-01 false Model code provisions for use in...

  3. 24 CFR 200.926c - Model code provisions for use in partially accepted code jurisdictions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... jurisdictions. If a lender or other interested party is notified that a State or local building code has been... in accordance with the applicable State or local building code, plus those additional requirements... 24 Housing and Urban Development 2 2012-04-01 2012-04-01 false Model code provisions for use in...

  4. Energy Efficiency Building Code for Commercial Buildings in Sri Lanka

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Busch, John; Greenberg, Steve; Rubinstein, Francis

    2000-09-30

    1.1.1 To encourage energy efficient design or retrofit of commercial buildings so that they may be constructed, operated, and maintained in a manner that reduces the use of energy without constraining the building function, the comfort, health, or the productivity of the occupants and with appropriate regard for economic considerations. 1.1.2 To provide criterion and minimum standards for energy efficiency in the design or retrofit of commercial buildings and provide methods for determining compliance with them. 1.1.3 To encourage energy efficient designs that exceed these criterion and minimum standards.

  5. Child Care Services and the NYS Uniform Fire Prevention and Building Code: A Building Code Examination of Child Day Care Services Which Are Regulated by the NYS Department of Social Services with Particular Attention to Day Care Centers and the Role of the Local Authority Having Jurisdiction.

    ERIC Educational Resources Information Center

    New York State Div. of Code Enforcement and Administration, Albany.

    This course manual details the Uniform Fire Prevention and Building Code of New York State and how it affects child care services, particularly day care centers. The sections of the manual, each detailing a part of the code, are: (1) Introduction, Scope, Registration, and Definitions and Facilities Regulated by the New York Department of Social…

  6. Reviews and syntheses: on the roles trees play in building and plumbing the critical zone

    NASA Astrophysics Data System (ADS)

    Brantley, Susan L.; Eissenstat, David M.; Marshall, Jill A.; Godsey, Sarah E.; Balogh-Brunstad, Zsuzsanna; Karwan, Diana L.; Papuga, Shirley A.; Roering, Joshua; Dawson, Todd E.; Evaristo, Jaivime; Chadwick, Oliver; McDonnell, Jeffrey J.; Weathers, Kathleen C.

    2017-11-01

    Trees, the most successful biological power plants on earth, build and plumb the critical zone (CZ) in ways that we do not yet understand. To encourage exploration of the character and implications of interactions between trees and soil in the CZ, we propose nine hypotheses that can be tested at diverse settings. The hypotheses are roughly divided into those about the architecture (building) and those about the water (plumbing) in the CZ, but the two functions are intertwined. Depending upon one's disciplinary background, many of the nine hypotheses listed below may appear obviously true or obviously false. (1) Tree roots can only physically penetrate and biogeochemically comminute the immobile substrate underlying mobile soil where that underlying substrate is fractured or pre-weathered. (2) In settings where the thickness of weathered material, H, is large, trees primarily shape the CZ through biogeochemical reactions within the rooting zone. (3) In forested uplands, the thickness of mobile soil, h, can evolve toward a steady state because of feedbacks related to root disruption and tree throw. (4) In settings where h ≪ H and the rates of uplift and erosion are low, the uptake of phosphorus into trees is buffered by the fine-grained fraction of the soil, and the ultimate source of this phosphorus is dust. (5) In settings of limited water availability, trees maintain the highest length density of functional roots at depths where water can be extracted over most of the growing season with the least amount of energy expenditure. (6) Trees grow the majority of their roots in the zone where the most growth-limiting resource is abundant, but they also grow roots at other depths to forage for other resources and to hydraulically redistribute those resources to depths where they can be taken up more efficiently. (7) Trees rely on matrix water in the unsaturated zone that at times may have an isotopic composition distinct from the gravity-drained water

  7. Reviews and syntheses: on the roles trees play in building and plumbing the critical zone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brantley, Susan L.; Eissenstat, David M.; Marshall, Jill A.

    Trees, the most successful biological power plants on earth, build and plumb the critical zone (CZ) in ways that we do not yet understand. To encourage exploration of the character and implications of interactions between trees and soil in the CZ, we propose nine hypotheses that can be tested at diverse settings. The hypotheses are roughly divided into those about the architecture (building) and those about the water (plumbing) in the CZ, but the two functions are intertwined. Depending upon one's disciplinary background, many of the nine hypotheses listed below may appear obviously true or obviously false. (1) Tree roots can onlymore » physically penetrate and biogeochemically comminute the immobile substrate underlying mobile soil where that underlying substrate is fractured or pre-weathered. (2) In settings where the thickness of weathered material, H, is large, trees primarily shape the CZ through biogeochemical reactions within the rooting zone. (3) In forested uplands, the thickness of mobile soil, h, can evolve toward a steady state because of feedbacks related to root disruption and tree throw. (4) In settings where h \\11 H and the rates of uplift and erosion are low, the uptake of phosphorus into trees is buffered by the fine-grained fraction of the soil, and the ultimate source of this phosphorus is dust. (5) In settings of limited water availability, trees maintain the highest length density of functional roots at depths where water can be extracted over most of the growing season with the least amount of energy expenditure. (6) Trees grow the majority of their roots in the zone where the most growth-limiting resource is abundant, but they also grow roots at other depths to forage for other resources and to hydraulically redistribute those resources to depths where they can be taken up more efficiently. (7) Trees rely on matrix water in the unsaturated zone that at times may have an isotopic composition distinct from the gravity-drained water

  8. Reviews and syntheses: on the roles trees play in building and plumbing the critical zone

    DOE PAGES

    Brantley, Susan L.; Eissenstat, David M.; Marshall, Jill A.; ...

    2017-11-17

    Trees, the most successful biological power plants on earth, build and plumb the critical zone (CZ) in ways that we do not yet understand. To encourage exploration of the character and implications of interactions between trees and soil in the CZ, we propose nine hypotheses that can be tested at diverse settings. The hypotheses are roughly divided into those about the architecture (building) and those about the water (plumbing) in the CZ, but the two functions are intertwined. Depending upon one's disciplinary background, many of the nine hypotheses listed below may appear obviously true or obviously false. (1) Tree roots can onlymore » physically penetrate and biogeochemically comminute the immobile substrate underlying mobile soil where that underlying substrate is fractured or pre-weathered. (2) In settings where the thickness of weathered material, H, is large, trees primarily shape the CZ through biogeochemical reactions within the rooting zone. (3) In forested uplands, the thickness of mobile soil, h, can evolve toward a steady state because of feedbacks related to root disruption and tree throw. (4) In settings where h \\11 H and the rates of uplift and erosion are low, the uptake of phosphorus into trees is buffered by the fine-grained fraction of the soil, and the ultimate source of this phosphorus is dust. (5) In settings of limited water availability, trees maintain the highest length density of functional roots at depths where water can be extracted over most of the growing season with the least amount of energy expenditure. (6) Trees grow the majority of their roots in the zone where the most growth-limiting resource is abundant, but they also grow roots at other depths to forage for other resources and to hydraulically redistribute those resources to depths where they can be taken up more efficiently. (7) Trees rely on matrix water in the unsaturated zone that at times may have an isotopic composition distinct from the gravity-drained water

  9. Development of probabilistic multimedia multipathway computer codes.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, C.; LePoire, D.; Gnanapragasam, E.

    2002-01-01

    The deterministic multimedia dose/risk assessment codes RESRAD and RESRAD-BUILD have been widely used for many years for evaluation of sites contaminated with residual radioactive materials. The RESRAD code applies to the cleanup of sites (soils) and the RESRAD-BUILD code applies to the cleanup of buildings and structures. This work describes the procedure used to enhance the deterministic RESRAD and RESRAD-BUILD codes for probabilistic dose analysis. A six-step procedure was used in developing default parameter distributions and the probabilistic analysis modules. These six steps include (1) listing and categorizing parameters; (2) ranking parameters; (3) developing parameter distributions; (4) testing parameter distributionsmore » for probabilistic analysis; (5) developing probabilistic software modules; and (6) testing probabilistic modules and integrated codes. The procedures used can be applied to the development of other multimedia probabilistic codes. The probabilistic versions of RESRAD and RESRAD-BUILD codes provide tools for studying the uncertainty in dose assessment caused by uncertain input parameters. The parameter distribution data collected in this work can also be applied to other multimedia assessment tasks and multimedia computer codes.« less

  10. Legacy Code Modernization

    NASA Technical Reports Server (NTRS)

    Hribar, Michelle R.; Frumkin, Michael; Jin, Haoqiang; Waheed, Abdul; Yan, Jerry; Saini, Subhash (Technical Monitor)

    1998-01-01

    Over the past decade, high performance computing has evolved rapidly; systems based on commodity microprocessors have been introduced in quick succession from at least seven vendors/families. Porting codes to every new architecture is a difficult problem; in particular, here at NASA, there are many large CFD applications that are very costly to port to new machines by hand. The LCM ("Legacy Code Modernization") Project is the development of an integrated parallelization environment (IPE) which performs the automated mapping of legacy CFD (Fortran) applications to state-of-the-art high performance computers. While most projects to port codes focus on the parallelization of the code, we consider porting to be an iterative process consisting of several steps: 1) code cleanup, 2) serial optimization,3) parallelization, 4) performance monitoring and visualization, 5) intelligent tools for automated tuning using performance prediction and 6) machine specific optimization. The approach for building this parallelization environment is to build the components for each of the steps simultaneously and then integrate them together. The demonstration will exhibit our latest research in building this environment: 1. Parallelizing tools and compiler evaluation. 2. Code cleanup and serial optimization using automated scripts 3. Development of a code generator for performance prediction 4. Automated partitioning 5. Automated insertion of directives. These demonstrations will exhibit the effectiveness of an automated approach for all the steps involved with porting and tuning a legacy code application for a new architecture.

  11. Analysis on energy-saving path of rural buildings in hot summer and cold winter zone

    NASA Astrophysics Data System (ADS)

    Huang, Mingqiang; Li, Jinheng

    2018-02-01

    Since the reform and opening policy, the construction of rural area in China has become more and more important. The idea of establishing green villages needs to be accepted and recognized by the public. The hot summer and cold winter zone combines two contradictory weather conditions that is cold winter and hot summer. So the living conditions are limited. In response to this climate, residents extensively use electric heaters or air conditioning to adjust the indoor temperature, resulting in energy waste and environmental pollution. In order to improve the living conditions of residents, rural area energy conservation has been put on the agenda. Based on the present situation and energy consumption analysis of the rural buildings in the hot summer and cold winter zone, this article puts forward several energy saving paths from government, construction technology and so on

  12. Analysis of the influence of the interlayer staggered zone in the basalt of Jinsha River Basin on the main buildings

    NASA Astrophysics Data System (ADS)

    Guo, Qiaona; Huang, Jiangwei

    2018-02-01

    In this paper, the finite element software FEFLOW is used to simulate the seepage field of the interlayer staggered zone C2 in the basalt of Jinsha River Basin. The influence of the interlayer staggered zone C2 on the building is analyzed. Combined with the waterproof effect of current design scheme of anti-seepage curtain, the seepage field in the interlayer staggered zone C2 is discussed under different design schemes. The optimal design scheme of anti-seepage curtain is put forward. The results showed that the case four can effectively reduce the head and hydraulic gradient of underground powerhouse area, and improve the groundwater seepage field in the plant area.

  13. Improving building energy efficiency in India: State-level analysis of building energy efficiency policies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Tan, Qing; Evans, Meredydd

    India is expected to add 40 billion m2 of new buildings till 2050. Buildings are responsible for one third of India’s total energy consumption today and building energy use is expected to continue growing driven by rapid income and population growth. The implementation of the Energy Conservation Building Code (ECBC) is one of the measures to improve building energy efficiency. Using the Global Change Assessment Model, this study assesses growth in the buildings sector and impacts of building energy policies in Gujarat, which would help the state adopt ECBC and expand building energy efficiency programs. Without building energy policies, buildingmore » energy use in Gujarat would grow by 15 times in commercial buildings and 4 times in urban residential buildings between 2010 and 2050. ECBC improves energy efficiency in commercial buildings and could reduce building electricity use in Gujarat by 20% in 2050, compared to the no policy scenario. Having energy codes for both commercial and residential buildings could result in additional 10% savings in electricity use. To achieve these intended savings, it is critical to build capacity and institution for robust code implementation.« less

  14. An accurate evaluation of the performance of asynchronous DS-CDMA systems with zero-correlation-zone coding in Rayleigh fading

    NASA Astrophysics Data System (ADS)

    Walker, Ernest; Chen, Xinjia; Cooper, Reginald L.

    2010-04-01

    An arbitrarily accurate approach is used to determine the bit-error rate (BER) performance for generalized asynchronous DS-CDMA systems, in Gaussian noise with Raleigh fading. In this paper, and the sequel, new theoretical work has been contributed which substantially enhances existing performance analysis formulations. Major contributions include: substantial computational complexity reduction, including a priori BER accuracy bounding; an analytical approach that facilitates performance evaluation for systems with arbitrary spectral spreading distributions, with non-uniform transmission delay distributions. Using prior results, augmented by these enhancements, a generalized DS-CDMA system model is constructed and used to evaluated the BER performance, in a variety of scenarios. In this paper, the generalized system modeling was used to evaluate the performance of both Walsh- Hadamard (WH) and Walsh-Hadamard-seeded zero-correlation-zone (WH-ZCZ) coding. The selection of these codes was informed by the observation that WH codes contain N spectral spreading values (0 to N - 1), one for each code sequence; while WH-ZCZ codes contain only two spectral spreading values (N/2 - 1,N/2); where N is the sequence length in chips. Since these codes span the spectral spreading range for DS-CDMA coding, by invoking an induction argument, the generalization of the system model is sufficiently supported. The results in this paper, and the sequel, support the claim that an arbitrary accurate performance analysis for DS-CDMA systems can be evaluated over the full range of binary coding, with minimal computational complexity.

  15. Assessment of the Potential to Achieve very Low Energy Use in Public Buildings in China with Advanced Window and Shading Systems

    DOE PAGES

    Lee, Eleanor; Pang, Xiufeng; McNeil, Andrew; ...

    2015-05-29

    Here, as rapid growth in the construction industry continues to occur in China, the increased demand for a higher standard living is driving significant growth in energy use and demand across the country. Building codes and standards have been implemented to head off this trend, tightening prescriptive requirements for fenestration component measures using methods similar to the US model energy code American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. The objective of this study is to (a) provide an overview of applicable code requirements and current efforts within China to enable characterization and comparison of window and shadingmore » products, and (b) quantify the load reduction and energy savings potential of several key advanced window and shading systems, given the divergent views on how space conditioning requirements will be met in the future. System-level heating and cooling loads and energy use performance were evaluated for a code-compliant large office building using the EnergyPlus building energy simulation program. Commercially-available, highly-insulating, low-emittance windows were found to produce 24-66% lower perimeter zone HVAC electricity use compared to the mandated energy-efficiency standard in force (GB 50189-2005) in cold climates like Beijing. Low-e windows with operable exterior shading produced up to 30-80% reductions in perimeter zone HVAC electricity use in Beijing and 18-38% reductions in Shanghai compared to the standard. The economic context of China is unique since the cost of labor and materials for the building industry is so low. Broad deployment of these commercially available technologies with the proper supporting infrastructure for design, specification, and verification in the field would enable significant reductions in energy use and greenhouse gas emissions in the near term.« less

  16. Assessment of the Potential to Achieve very Low Energy Use in Public Buildings in China with Advanced Window and Shading Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Eleanor; Pang, Xiufeng; McNeil, Andrew

    Here, as rapid growth in the construction industry continues to occur in China, the increased demand for a higher standard living is driving significant growth in energy use and demand across the country. Building codes and standards have been implemented to head off this trend, tightening prescriptive requirements for fenestration component measures using methods similar to the US model energy code American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. The objective of this study is to (a) provide an overview of applicable code requirements and current efforts within China to enable characterization and comparison of window and shadingmore » products, and (b) quantify the load reduction and energy savings potential of several key advanced window and shading systems, given the divergent views on how space conditioning requirements will be met in the future. System-level heating and cooling loads and energy use performance were evaluated for a code-compliant large office building using the EnergyPlus building energy simulation program. Commercially-available, highly-insulating, low-emittance windows were found to produce 24-66% lower perimeter zone HVAC electricity use compared to the mandated energy-efficiency standard in force (GB 50189-2005) in cold climates like Beijing. Low-e windows with operable exterior shading produced up to 30-80% reductions in perimeter zone HVAC electricity use in Beijing and 18-38% reductions in Shanghai compared to the standard. The economic context of China is unique since the cost of labor and materials for the building industry is so low. Broad deployment of these commercially available technologies with the proper supporting infrastructure for design, specification, and verification in the field would enable significant reductions in energy use and greenhouse gas emissions in the near term.« less

  17. Collapse risk of buildings in the Pacific Northwest region due to subduction earthquakes

    USGS Publications Warehouse

    Raghunandan, Meera; Liel, Abbie B.; Luco, Nicolas

    2015-01-01

    Subduction earthquakes similar to the 2011 Japan and 2010 Chile events will occur in the future in the Cascadia subduction zone in the Pacific Northwest. In this paper, nonlinear dynamic analyses are carried out on 24 buildings designed according to outdated and modern building codes for the cities of Seattle, Washington, and Portland, Oregon. The results indicate that the median collapse capacity of the ductile (post-1970) buildings is approximately 40% less when subjected to ground motions from subduction, as compared to crustal earthquakes. Buildings are more susceptible to earthquake-induced collapse when shaken by subduction records (as compared to crustal records of the same intensity) because the subduction motions tend to be longer in duration due to their larger magnitude and the greater source-to-site distance. As a result, subduction earthquakes are shown to contribute to the majority of the collapse risk of the buildings analyzed.

  18. Preserving Envelope Efficiency in Performance Based Code Compliance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thornton, Brian A.; Sullivan, Greg P.; Rosenberg, Michael I.

    2015-06-20

    The City of Seattle 2012 Energy Code (Seattle 2014), one of the most progressive in the country, is under revision for its 2015 edition. Additionally, city personnel participate in the development of the next generation of the Washington State Energy Code and the International Energy Code. Seattle has pledged carbon neutrality by 2050 including buildings, transportation and other sectors. The United States Department of Energy (DOE), through Pacific Northwest National Laboratory (PNNL) provided technical assistance to Seattle in order to understand the implications of one potential direction for its code development, limiting trade-offs of long-lived building envelope components less stringentmore » than the prescriptive code envelope requirements by using better-than-code but shorter-lived lighting and heating, ventilation, and air-conditioning (HVAC) components through the total building performance modeled energy compliance path. Weaker building envelopes can permanently limit building energy performance even as lighting and HVAC components are upgraded over time, because retrofitting the envelope is less likely and more expensive. Weaker building envelopes may also increase the required size, cost and complexity of HVAC systems and may adversely affect occupant comfort. This report presents the results of this technical assistance. The use of modeled energy code compliance to trade-off envelope components with shorter-lived building components is not unique to Seattle and the lessons and possible solutions described in this report have implications for other jurisdictions and energy codes.« less

  19. Thermal comfort in naturally ventilated and air-conditioned buildings in humid subtropical climate zone in China

    NASA Astrophysics Data System (ADS)

    Yang, Wei; Zhang, Guoqiang

    2008-05-01

    A thermal comfort field study has been carried out in five cities in the humid subtropical climate zone in China. The survey was performed in naturally ventilated and air-conditioned buildings during the summer season in 2006. There were 229 occupants from 111 buildings who participated in this study and 229 questionnaire responses were collected. Thermal acceptability assessment reveals that the indoor environment in naturally ventilated buildings could not meet the 80% acceptability criteria prescribed by ASHRAE Standard 55, and people tended to feel more comfortable in air-conditioned buildings with the air-conditioned occupants voting with higher acceptability (89%) than the naturally ventilated occupants (58%). The neutral temperatures in naturally ventilated and air-conditioned buildings were 28.3°C and 27.7°C, respectively. The range of accepted temperature in naturally ventilated buildings (25.0˜31.6°C) was wider than that in air-conditioned buildings (25.1˜30.3°C), which suggests that occupants in naturally ventilated buildings seemed to be more tolerant of higher temperatures. Preferred temperatures were 27.9°C and 27.3°C in naturally ventilated and air-conditioned buildings, respectively, both of which were 0.4°C cooler than neutral temperatures. This result suggests that people of hot climates may use words like “slightly cool” to describe their preferred thermal state. The relationship between draught sensation and indoor air velocity at different temperature ranges indicates that indoor air velocity had a significant influence over the occupants’ comfort sensation, and air velocities required by occupants increased with the increasing of operative temperatures. Thus, an effective way of natural ventilation which can create the preferred higher air movement is called for. Finally, the indoor set-point temperature of 26°C or even higher in air-conditioned buildings was confirmed as making people comfortable, which supports the regulation

  20. Increasing Flexibility in Energy Code Compliance: Performance Packages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, Philip R.; Rosenberg, Michael I.

    Energy codes and standards have provided significant increases in building efficiency over the last 38 years, since the first national energy code was published in late 1975. The most commonly used path in energy codes, the prescriptive path, appears to be reaching a point of diminishing returns. As the code matures, the prescriptive path becomes more complicated, and also more restrictive. It is likely that an approach that considers the building as an integrated system will be necessary to achieve the next real gains in building efficiency. Performance code paths are increasing in popularity; however, there remains a significant designmore » team overhead in following the performance path, especially for smaller buildings. This paper focuses on development of one alternative format, prescriptive packages. A method to develop building-specific prescriptive packages is reviewed based on a multiple runs of prototypical building models that are used to develop parametric decision analysis to determines a set of packages with equivalent energy performance. The approach is designed to be cost-effective and flexible for the design team while achieving a desired level of energy efficiency performance. A demonstration of the approach based on mid-sized office buildings with two HVAC system types is shown along with a discussion of potential applicability in the energy code process.« less

  1. An interactive method for digitizing zone maps

    NASA Technical Reports Server (NTRS)

    Giddings, L. E.; Thompson, E. J.

    1975-01-01

    A method is presented for digitizing maps that consist of zones, such as contour or climatic zone maps. A color-coded map is prepared by any convenient process. The map is then read into memory of an Image 100 computer by means of its table scanner, using colored filters. Zones are separated and stored in themes, using standard classification procedures. Thematic data are written on magnetic tape and these data, appropriately coded, are combined to make a digitized image on tape. Step-by-step procedures are given for digitization of crop moisture index maps with this procedure. In addition, a complete example of the digitization of a climatic zone map is given.

  2. 77 FR 29322 - Updating State Residential Building Energy Efficiency Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-17

    ... supporting the change to the SHGC requirements in climate zone 4. Specifically, RECA supported the... to change Climate Zone 3 from R13 to either R20 or R13+5 ci.'' (CFEC, No. 2 at p. 2) In response, DOE... difference of 50 Pascals (5 ACH50) in climate zone 1 and climate zone 2; and 3 air changes/hour (3 ACH50) in...

  3. Green Building Tools for Tribes

    EPA Pesticide Factsheets

    Tribal green building tools and funding information to support tribal building code adoption, healthy building, siting, energy efficiency, renewable energy, water conservation, green building materials, recycling and adaptation and resilience.

  4. Mortality during a Large-Scale Heat Wave by Place, Demographic Group, Internal and External Causes of Death, and Building Climate Zone

    PubMed Central

    Joe, Lauren; Hoshiko, Sumi; Dobraca, Dina; Jackson, Rebecca; Smorodinsky, Svetlana; Smith, Daniel; Harnly, Martha

    2016-01-01

    Mortality increases during periods of elevated heat. Identification of vulnerable subgroups by demographics, causes of death, and geographic regions, including deaths occurring at home, is needed to inform public health prevention efforts. We calculated mortality relative risks (RRs) and excess deaths associated with a large-scale California heat wave in 2006, comparing deaths during the heat wave with reference days. For total (all-place) and at-home mortality, we examined risks by demographic factors, internal and external causes of death, and building climate zones. During the heat wave, 582 excess deaths occurred, a 5% increase over expected (RR = 1.05, 95% confidence interval (CI) 1.03–1.08). Sixty-six percent of excess deaths were at home (RR = 1.12, CI 1.07–1.16). Total mortality risk was higher among those aged 35–44 years than ≥65, and among Hispanics than whites. Deaths from external causes increased more sharply (RR = 1.18, CI 1.10–1.27) than from internal causes (RR = 1.04, CI 1.02–1.07). Geographically, risk varied by building climate zone; the highest risks of at-home death occurred in the northernmost coastal zone (RR = 1.58, CI 1.01–2.48) and the southernmost zone of California’s Central Valley (RR = 1.43, CI 1.21–1.68). Heat wave mortality risk varied across subpopulations, and some patterns of vulnerability differed from those previously identified. Public health efforts should also address at-home mortality, non-elderly adults, external causes, and at-risk geographic regions. PMID:27005646

  5. Mortality during a Large-Scale Heat Wave by Place, Demographic Group, Internal and External Causes of Death, and Building Climate Zone.

    PubMed

    Joe, Lauren; Hoshiko, Sumi; Dobraca, Dina; Jackson, Rebecca; Smorodinsky, Svetlana; Smith, Daniel; Harnly, Martha

    2016-03-09

    Mortality increases during periods of elevated heat. Identification of vulnerable subgroups by demographics, causes of death, and geographic regions, including deaths occurring at home, is needed to inform public health prevention efforts. We calculated mortality relative risks (RRs) and excess deaths associated with a large-scale California heat wave in 2006, comparing deaths during the heat wave with reference days. For total (all-place) and at-home mortality, we examined risks by demographic factors, internal and external causes of death, and building climate zones. During the heat wave, 582 excess deaths occurred, a 5% increase over expected (RR = 1.05, 95% confidence interval (CI) 1.03-1.08). Sixty-six percent of excess deaths were at home (RR = 1.12, CI 1.07-1.16). Total mortality risk was higher among those aged 35-44 years than ≥ 65, and among Hispanics than whites. Deaths from external causes increased more sharply (RR = 1.18, CI 1.10-1.27) than from internal causes (RR = 1.04, CI 1.02-1.07). Geographically, risk varied by building climate zone; the highest risks of at-home death occurred in the northernmost coastal zone (RR = 1.58, CI 1.01-2.48) and the southernmost zone of California's Central Valley (RR = 1.43, CI 1.21-1.68). Heat wave mortality risk varied across subpopulations, and some patterns of vulnerability differed from those previously identified. Public health efforts should also address at-home mortality, non-elderly adults, external causes, and at-risk geographic regions.

  6. Tribal Green Building Toolkit

    EPA Pesticide Factsheets

    This Tribal Green Building Toolkit (Toolkit) is designed to help tribal officials, community members, planners, developers, and architects develop and adopt building codes to support green building practices. Anyone can use this toolkit!

  7. Building America Case Study: Rehabilitation of USDA Multifamily Homes, Georgia (Climate Zones 2-4)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rea Ventures Group, LLC, (Rea Ventures) partnered with Southface Energy Institute (Southface) on the rehabilitation of 418 low-income rental multifamily apartments located at 14 different properties in Georgia (Climate Zones 2-4). These 22-year old, individually-metered units were arranged in rowhouse or townhouse style units. Rehabilitation plans were developed using a process prescribed by the US Department of Agriculture (USDA) Rural Development program, who partially funded the building upgrades. The USDA is responsible for building, upgrading, and subsidizing housing in rural areas nationwide. In 2012, over $100 million was allocated in grants and loans. Due to the unique financing mechanism asmore » well as long-term ownership requirements, property owners are especially motivated to invest in upgrades that will increase durability and tenant retention. These buildings represent a large stock of rural affordable housing that have the potential for significant energy and cost savings for property owners and tenants. Southface analyzed the energy upgrade potential of one stereotypical property in the Rea Ventures portfolio. This study will provide insight into the most cost-effective, implementable energy efficiency and durability upgrades for this age multifamily housing, having an enormous impact not only on the portfolio of Rea Ventures but on the vast USDA and larger Federal portfolio. Additionally, Southface will identify gaps in the current capital needs assessment process, examine available audit and simulation tools and protocols, and evaluate additional auditor training or certification needs.« less

  8. Feedback Codes and Action Plans: Building the Capacity of First-Year Students to Apply Feedback to a Scientific Report

    ERIC Educational Resources Information Center

    Bird, Fiona L.; Yucel, Robyn

    2015-01-01

    Effective feedback can build self-assessment skills in students so that they become more competent and confident to identify and self-correct weaknesses in their work. In this study, we trialled a feedback code as part of an integrated programme of formative and summative assessment tasks, which provided feedback to first-year students on their…

  9. Green Building Standards

    EPA Pesticide Factsheets

    Many organizations have developed model codes or rating systems that communities may use to develop green building programs or revise building ordinances. Some of the major options are listed on this page.

  10. Monitoring the Deformation of High-Rise Buildings in Shanghai Luijiazui Zone by Tomo-Psinsar

    NASA Astrophysics Data System (ADS)

    Zhou, L. F.; Ma, P. F.; Xia, Y.; Xie, C. H.

    2018-05-01

    In this study, we utilize a Tomography-based Persistent Scatterers Interferometry (Tomo-PSInSAR) approach for monitoring the deformation performances of high-rise buildings, i.e. SWFC and Jin Mao Tower, in Shanghai Lujiazui Zone. For the purpose of this study, we use 31 Stripmap acquisitions from TerraSAR-X missions, spanning from December 2009 to February 2013. Considering thermal expansion, creep and shrinkage are two long-term movements that occur in high-rise buildings with concrete structures, we use an extended 4-D SAR phase model, and three parameters (height, deformation velocity, and thermal amplitude) are estimated simultaneously. Moreover, we apply a two-tier network strategy to detect single and double PSs with no need for preliminary removal of the atmospheric phase screen (APS) in the study area, avoiding possible error caused by the uncertainty in spatiotemporal filtering. Thermal expansion is illustrated in the thermal amplitude map, and deformation due to creep and shrinkage is revealed in the linear deformation velocity map. The thermal amplitude map demonstrates that the derived thermal amplitude of the two high-rise buildings both dilate and contract periodically, which is highly related to the building height due to the upward accumulative effect of thermal expansion. The linear deformation velocity map reveals that SWFC is subject to deformation during the new built period due to creep and shrinkage, which is height-dependent movements in the linear velocity map. It is worth mention that creep and shrinkage induces movements that increase with the increasing height in the downward direction. In addition, the deformation rates caused by creep and shrinkage are largest at the beginning and gradually decrease, and at last achieve a steady state as time goes infinity. On the contrary, the linear deformation velocity map shows that Jin Mao Tower is almost stable, and the reason is that it is an old built building, which is not influenced by creep

  11. Impact of a Large San Andreas Fault Earthquake on Tall Buildings in Southern California

    NASA Astrophysics Data System (ADS)

    Krishnan, S.; Ji, C.; Komatitsch, D.; Tromp, J.

    2004-12-01

    In 1857, an earthquake of magnitude 7.9 occurred on the San Andreas fault, starting at Parkfield and rupturing in a southeasterly direction for more than 300~km. Such a unilateral rupture produces significant directivity toward the San Fernando and Los Angeles basins. The strong shaking in the basins due to this earthquake would have had a significant long-period content (2--8~s). If such motions were to happen today, they could have a serious impact on tall buildings in Southern California. In order to study the effects of large San Andreas fault earthquakes on tall buildings in Southern California, we use the finite source of the magnitude 7.9 2001 Denali fault earthquake in Alaska and map it onto the San Andreas fault with the rupture originating at Parkfield and proceeding southward over a distance of 290~km. Using the SPECFEM3D spectral element seismic wave propagation code, we simulate a Denali-like earthquake on the San Andreas fault and compute ground motions at sites located on a grid with a 2.5--5.0~km spacing in the greater Southern California region. We subsequently analyze 3D structural models of an existing tall steel building designed in 1984 as well as one designed according to the current building code (Uniform Building Code, 1997) subjected to the computed ground motion. We use a sophisticated nonlinear building analysis program, FRAME3D, that has the ability to simulate damage in buildings due to three-component ground motion. We summarize the performance of these structural models on contour maps of carefully selected structural performance indices. This study could benefit the city in laying out emergency response strategies in the event of an earthquake on the San Andreas fault, in undertaking appropriate retrofit measures for tall buildings, and in formulating zoning regulations for new construction. In addition, the study would provide risk data associated with existing and new construction to insurance companies, real estate developers, and

  12. Transforming Markets for Energy-Efficient Buildings in China: Final Report on Activity Conducted by the Institute for Market Transformation (IMT) Under Cooperative Agreement DE-FC01-00EE10672 with the U.S. Department of Energy (DOE)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chao, Mark

    This report summarizes activity conducted by the Institute for Market Transformation and a team of American and Chinese partners in development of a new building energy-efficiency code for the transitional climate zone in the People's Republic of China.

  13. BOCA BASIC BUILDING CODE. 4TH ED., 1965 AND 1967. BOCA BASIC BUILDING CODE ACCUMULATIVE SUPPLEMENT.

    ERIC Educational Resources Information Center

    Building Officials Conference of America, Inc., Chicago, IL.

    NATIONALLY RECOGNIZED STANDARDS FOR THE EVALUATION OF MINIMUM SAFE PRACTICE OR FOR DETERMINING THE PERFORMANCE OF MATERIALS OR SYSTEMS OF CONSTRUCTION HAVE BEEN COMPILED AS AN AID TO DESIGNERS AND LOCAL OFFICIALS. THE CODE PRESENTS REGULATIONS IN TERMS OF MEASURED PERFORMANCE RATHER THAN IN RIGID SPECIFICATION OF MATERIALS OR METHODS. THE AREAS…

  14. Codes Don't Always Get Enforced, But Contracts Do: Changing the Procurement Paradigm to Drive Building Energy Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torcellini, Paul A; Scheib, Jennifer G; Pless, Shanti

    New construction could account for more than 25% of the U.S. energy consumption by 2030. Millions of square feet are built every year that will not perform as expected - despite advancing codes, rating systems, super-efficient technologies, and advanced utility programs. With retrofits of these under-performers decades away, savings potential will be lost for years to come. Only the building owner is in the driver's seat to demand - and verify - higher-performing buildings. Yet our current policy and market interventions really target the design team, not the owner. Accelerate Performance, a U.S. Department of Energy funded initiative, is changingmore » the building procurement approach to drive deeper, verified savings in three pilot states: Illinois, Minnesota, and Connecticut. Performance-based procurement ties energy performance to design and contractor team compensation while freeing them to meet energy targets with strategies most familiar to them. The process teases out the creativity of the design and contracting teams to deliver energy performance - without driving up the construction cost. The paper will share early results and lessons learned from new procurement and contract approaches in government, public, and private sector building projects. The paper provides practical guidance for building owners, facilities managers, design, and contractor teams who wish to incorporate effective performance-based procurement for deeper energy savings in their buildings.« less

  15. New Site Coefficients and Site Classification System Used in Recent Building Seismic Code Provisions

    USGS Publications Warehouse

    Dobry, R.; Borcherdt, R.D.; Crouse, C.B.; Idriss, I.M.; Joyner, W.B.; Martin, G.R.; Power, M.S.; Rinne, E.E.; Seed, R.B.

    2000-01-01

    Recent code provisions for buildings and other structures (1994 and 1997 NEHRP Provisions, 1997 UBC) have adopted new site amplification factors and a new procedure for site classification. Two amplitude-dependent site amplification factors are specified: Fa for short periods and Fv for longer periods. Previous codes included only a long period factor S and did not provide for a short period amplification factor. The new site classification system is based on definitions of five site classes in terms of a representative average shear wave velocity to a depth of 30 m (V?? s). This definition permits sites to be classified unambiguously. When the shear wave velocity is not available, other soil properties such as standard penetration resistance or undrained shear strength can be used. The new site classes denoted by letters A - E, replace site classes in previous codes denoted by S1 - S4. Site classes A and B correspond to hard rock and rock, Site Class C corresponds to soft rock and very stiff / very dense soil, and Site Classes D and E correspond to stiff soil and soft soil. A sixth site class, F, is defined for soils requiring site-specific evaluations. Both Fa and Fv are functions of the site class, and also of the level of seismic hazard on rock, defined by parameters such as Aa and Av (1994 NEHRP Provisions), Ss and S1 (1997 NEHRP Provisions) or Z (1997 UBC). The values of Fa and Fv decrease as the seismic hazard on rock increases due to soil nonlinearity. The greatest impact of the new factors Fa and Fv as compared with the old S factors occurs in areas of low-to-medium seismic hazard. This paper summarizes the new site provisions, explains the basis for them, and discusses ongoing studies of site amplification in recent earthquakes that may influence future code developments.

  16. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Minimum Property Standards § 200.925c Model codes. (a... Plumbing Code, 1993 Edition, and the BOCA National Mechanical Code, 1993 Edition, excluding Chapter I, Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood...

  17. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Minimum Property Standards § 200.925c Model codes. (a... Plumbing Code, 1993 Edition, and the BOCA National Mechanical Code, 1993 Edition, excluding Chapter I, Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood...

  18. Communities on the Move: Pedestrian-Oriented Zoning as a Facilitator of Adult Active Travel to Work in the United States.

    PubMed

    Chriqui, Jamie F; Leider, Julien; Thrun, Emily; Nicholson, Lisa M; Slater, Sandy

    2016-01-01

    Communities across the United States have been reforming their zoning codes to create pedestrian-friendly neighborhoods with increased street connectivity, mixed use and higher density, open space, transportation infrastructure, and a traditional neighborhood structure. Zoning code reforms include new urbanist zoning such as the SmartCode, form-based codes, transects, transportation and pedestrian-oriented developments, and traditional neighborhood developments. To examine the relationship of zoning code reforms and more active living--oriented zoning provisions with adult active travel to work via walking, biking, or by using public transit. Zoning codes effective as of 2010 were compiled for 3,914 municipal-level jurisdictions located in 471 counties and 2 consolidated cities in 48 states and the District of Columbia, and that collectively covered 72.9% of the U.S. population. Zoning codes were evaluated for the presence of code reform zoning and nine pedestrian-oriented zoning provisions (1 = yes): sidewalks, crosswalks, bike-pedestrian connectivity, street connectivity, bike lanes, bike parking, bike-pedestrian trails/paths, mixed-use development, and other walkability/pedestrian orientation. A zoning scale reflected the number of provisions addressed (out of 10). Five continuous outcome measures were constructed using 2010-2014 American Community Survey municipal-level 5-year estimates to assess the percentage of workers: walking, biking, walking or biking, or taking public transit to work OR engaged in any active travel to work. Regression models controlled for municipal-level socioeconomic characteristics and a GIS-constructed walkability scale and were clustered on county with robust standard errors. Adjusted models indicated that several pedestrian-oriented zoning provisions were statistically associated (p < 0.05 or lower) with increased rates of walking, biking, or engaging in any active travel (walking, biking, or any active travel) to work

  19. HBT+: an improved code for finding subhaloes and building merger trees in cosmological simulations

    NASA Astrophysics Data System (ADS)

    Han, Jiaxin; Cole, Shaun; Frenk, Carlos S.; Benitez-Llambay, Alejandro; Helly, John

    2018-02-01

    Dark matter subhalos are the remnants of (incomplete) halo mergers. Identifying them and establishing their evolutionary links in the form of merger trees is one of the most important applications of cosmological simulations. The HBT (Hierachical Bound-Tracing) code identifies haloes as they form and tracks their evolution as they merge, simultaneously detecting subhaloes and building their merger trees. Here we present a new implementation of this approach, HBT+ , that is much faster, more user friendly, and more physically complete than the original code. Applying HBT+ to cosmological simulations, we show that both the subhalo mass function and the peak-mass function are well fitted by similar double-Schechter functions. The ratio between the two is highest at the high-mass end, reflecting the resilience of massive subhaloes that experience substantial dynamical friction but limited tidal stripping. The radial distribution of the most-massive subhaloes is more concentrated than the universal radial distribution of lower mass subhaloes. Subhalo finders that work in configuration space tend to underestimate the masses of massive subhaloes, an effect that is stronger in the host centre. This may explain, at least in part, the excess of massive subhaloes in galaxy cluster centres inferred from recent lensing observations. We demonstrate that the peak-mass function is a powerful diagnostic of merger tree defects, and the merger trees constructed using HBT+ do not suffer from the missing or switched links that tend to afflict merger trees constructed from more conventional halo finders. We make the HBT+ code publicly available.

  20. Energy Codes at a Glance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Pamala C.; Richman, Eric E.

    2008-09-01

    Feeling dim from energy code confusion? Read on to give your inspections a charge. The U.S. Department of Energy’s Building Energy Codes Program addresses hundreds of inquiries from the energy codes community every year. This article offers clarification for topics of confusion submitted to BECP Technical Support of interest to electrical inspectors, focusing on the residential and commercial energy code requirements based on the most recently published 2006 International Energy Conservation Code® and ANSI/ASHRAE/IESNA1 Standard 90.1-2004.

  1. The need for standards and codes to ensure an acoustically comfortable environment in multifamily housing buildings in Mexico City

    NASA Astrophysics Data System (ADS)

    Kotasek Gonzalez, Eduardo; Rodriguez Manzo, Fausto

    2002-11-01

    It is clear that almost all kinds of buildings require protection against noise and undesirable sounds, however, there are some countries where this is not yet regulated, such is the case of Mexico. Mexico City, the biggest city in the world could also be the noisiest. This is a problem which is today being debated; in fact there is no doubt that this has an important influence on the acoustic comfort conditions of dwellings, besides the habits and culture of the inhabitants, which are very different from those in the Anglo-Saxon countries. These are all details that must be taken into account in the design of an acoustic comfort standard for buildings in cities like Mexico. In this paper we deal with this problem and it suggests some recommendations to consider in a proposed acoustic comfort standard or code to be applied in the design of multifamily housing buildings in Mexico City.

  2. Modelica buildings library

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wetter, Michael; Zuo, Wangda; Nouidui, Thierry S.

    This paper describes the Buildings library, a free open-source library that is implemented in Modelica, an equation-based object-oriented modeling language. The library supports rapid prototyping, as well as design and operation of building energy and control systems. First, we describe the scope of the library, which covers HVAC systems, multi-zone heat transfer and multi-zone airflow and contaminant transport. Next, we describe differentiability requirements and address how we implemented them. We describe the class hierarchy that allows implementing component models by extending partial implementations of base models of heat and mass exchangers, and by instantiating basic models for conservation equations andmore » flow resistances. We also describe associated tools for pre- and post-processing, regression tests, co-simulation and real-time data exchange with building automation systems. Furthermore, the paper closes with an example of a chilled water plant, with and without water-side economizer, in which we analyzed the system-level efficiency for different control setpoints.« less

  3. Modelica buildings library

    DOE PAGES

    Wetter, Michael; Zuo, Wangda; Nouidui, Thierry S.; ...

    2013-03-13

    This paper describes the Buildings library, a free open-source library that is implemented in Modelica, an equation-based object-oriented modeling language. The library supports rapid prototyping, as well as design and operation of building energy and control systems. First, we describe the scope of the library, which covers HVAC systems, multi-zone heat transfer and multi-zone airflow and contaminant transport. Next, we describe differentiability requirements and address how we implemented them. We describe the class hierarchy that allows implementing component models by extending partial implementations of base models of heat and mass exchangers, and by instantiating basic models for conservation equations andmore » flow resistances. We also describe associated tools for pre- and post-processing, regression tests, co-simulation and real-time data exchange with building automation systems. Furthermore, the paper closes with an example of a chilled water plant, with and without water-side economizer, in which we analyzed the system-level efficiency for different control setpoints.« less

  4. Code Verification Results of an LLNL ASC Code on Some Tri-Lab Verification Test Suite Problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, S R; Bihari, B L; Salari, K

    As scientific codes become more complex and involve larger numbers of developers and algorithms, chances for algorithmic implementation mistakes increase. In this environment, code verification becomes essential to building confidence in the code implementation. This paper will present first results of a new code verification effort within LLNL's B Division. In particular, we will show results of code verification of the LLNL ASC ARES code on the test problems: Su Olson non-equilibrium radiation diffusion, Sod shock tube, Sedov point blast modeled with shock hydrodynamics, and Noh implosion.

  5. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Seismic Regulation for New Buildings. (b) Each of the following model codes or standards provides a level...) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code... buildings. 1792.103 Section 1792.103 Agriculture Regulations of the Department of Agriculture (Continued...

  6. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Seismic Regulation for New Buildings. (b) Each of the following model codes or standards provides a level...) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code... buildings. 1792.103 Section 1792.103 Agriculture Regulations of the Department of Agriculture (Continued...

  7. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Seismic Regulation for New Buildings. (b) Each of the following model codes or standards provides a level...) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code... buildings. 1792.103 Section 1792.103 Agriculture Regulations of the Department of Agriculture (Continued...

  8. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Seismic Regulation for New Buildings. (b) Each of the following model codes or standards provides a level...) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code... buildings. 1792.103 Section 1792.103 Agriculture Regulations of the Department of Agriculture (Continued...

  9. Piecemeal Buildup of the Genetic Code, Ribosomes, and Genomes from Primordial tRNA Building Blocks.

    PubMed

    Caetano-Anollés, Derek; Caetano-Anollés, Gustavo

    2016-12-02

    The origin of biomolecular machinery likely centered around an ancient and central molecule capable of interacting with emergent macromolecular complexity. tRNA is the oldest and most central nucleic acid molecule of the cell. Its co-evolutionary interactions with aminoacyl-tRNA synthetase protein enzymes define the specificities of the genetic code and those with the ribosome their accurate biosynthetic interpretation. Phylogenetic approaches that focus on molecular structure allow reconstruction of evolutionary timelines that describe the history of RNA and protein structural domains. Here we review phylogenomic analyses that reconstruct the early history of the synthetase enzymes and the ribosome, their interactions with RNA, and the inception of amino acid charging and codon specificities in tRNA that are responsible for the genetic code. We also trace the age of domains and tRNA onto ancient tRNA homologies that were recently identified in rRNA. Our findings reveal a timeline of recruitment of tRNA building blocks for the formation of a functional ribosome, which holds both the biocatalytic functions of protein biosynthesis and the ability to store genetic memory in primordial RNA genomic templates.

  10. Piecemeal Buildup of the Genetic Code, Ribosomes, and Genomes from Primordial tRNA Building Blocks

    PubMed Central

    Caetano-Anollés, Derek; Caetano-Anollés, Gustavo

    2016-01-01

    The origin of biomolecular machinery likely centered around an ancient and central molecule capable of interacting with emergent macromolecular complexity. tRNA is the oldest and most central nucleic acid molecule of the cell. Its co-evolutionary interactions with aminoacyl-tRNA synthetase protein enzymes define the specificities of the genetic code and those with the ribosome their accurate biosynthetic interpretation. Phylogenetic approaches that focus on molecular structure allow reconstruction of evolutionary timelines that describe the history of RNA and protein structural domains. Here we review phylogenomic analyses that reconstruct the early history of the synthetase enzymes and the ribosome, their interactions with RNA, and the inception of amino acid charging and codon specificities in tRNA that are responsible for the genetic code. We also trace the age of domains and tRNA onto ancient tRNA homologies that were recently identified in rRNA. Our findings reveal a timeline of recruitment of tRNA building blocks for the formation of a functional ribosome, which holds both the biocatalytic functions of protein biosynthesis and the ability to store genetic memory in primordial RNA genomic templates. PMID:27918435

  11. Assessing the optimality of ASHRAE climate zones using high resolution meteorological data sets

    NASA Astrophysics Data System (ADS)

    Fils, P. D.; Kumar, J.; Collier, N.; Hoffman, F. M.; Xu, M.; Forbes, W.

    2017-12-01

    Energy consumed by built infrastructure constitutes a significant fraction of the nation's energy budget. According to 2015 US Energy Information Agency report, 41% of the energy used in the US was going to residential and commercial buildings. Additional research has shown that 32% of commercial building energy goes into heating and cooling the building. The American National Standards Institute and the American Society of Heating Refrigerating and Air-Conditioning Engineers Standard 90.1 provides climate zones for current state-of-practice since heating and cooling demands are strongly influenced by spatio-temporal weather variations. For this reason, we have been assessing the optimality of the climate zones using high resolution daily climate data from NASA's DAYMET database. We analyzed time series of meteorological data sets for all ASHRAE climate zones between 1980-2016 inclusively. We computed the mean, standard deviation, and other statistics for a set of meteorological variables (solar radiation, maximum and minimum temperature)within each zone. By plotting all the zonal statistics, we analyzed patterns and trends in those data over the past 36 years. We compared the means of each zone to its standard deviation to determine the range of spatial variability that exist within each zone. If the band around the mean is too large, it indicates that regions in the zone experience a wide range of weather conditions and perhaps a common set of building design guidelines would lead to a non-optimal energy consumption scenario. In this study we have observed a strong variation in the different climate zones. Some have shown consistent patterns in the past 36 years, indicating that the zone was well constructed, while others have greatly deviated from their mean indicating that the zone needs to be reconstructed. We also looked at redesigning the climate zones based on high resolution climate data. We are using building simulations models like EnergyPlus to develop

  12. Continuation of research into language concepts for the mission support environment: Source code

    NASA Technical Reports Server (NTRS)

    Barton, Timothy J.; Ratner, Jeremiah M.

    1991-01-01

    Research into language concepts for the Mission Control Center is presented. A computer code for source codes is presented. The file contains the routines which allow source code files to be created and compiled. The build process assumes that all elements and the COMP exist in the current directory. The build process places as much code generation as possible on the preprocessor as possible. A summary is given of the source files as used and/or manipulated by the build routine.

  13. 76 FR 42688 - Updating State Residential Building Energy Efficiency Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-19

    ... 19, 2013. ADDRESSES: Certification Statements must be addressed to the Buildings Technologies Program...-rise (greater than three stories) multifamily residential buildings and hotel, motel, and other..., townhouses, row houses, and low-rise multifamily buildings (not greater than three stories) such as...

  14. Safe Building Code Incentive Act of 2011

    THOMAS, 112th Congress

    Rep. Diaz-Balart, Mario [R-FL-21

    2011-06-01

    House - 06/02/2011 Referred to the Subcommittee on Economic Development, Public Buildings and Emergency Management. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  15. Safe Building Code Incentive Act of 2009

    THOMAS, 111th Congress

    Rep. Diaz-Balart, Mario [R-FL-25

    2009-05-21

    House - 05/22/2009 Referred to the Subcommittee on Economic Development, Public Buildings and Emergency Management. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  16. Safe Building Code Incentive Act of 2013

    THOMAS, 113th Congress

    Rep. Diaz-Balart, Mario [R-FL-25

    2013-05-08

    House - 05/09/2013 Referred to the Subcommittee on Economic Development, Public Buildings and Emergency Management. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  17. 76 FR 56413 - Building Energy Codes Cost Analysis

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-13

    ... the by-zone housing starts of Table 2. \\7\\ See http://rredc.nrel.gov/solar/old_data/nsrdb/tmy2... as an alternative investment rate. Thus the present value, (PV) of a cash flow in year Y (CFy) is...

  18. Automating RPM Creation from a Source Code Repository

    DTIC Science & Technology

    2012-02-01

    apps/usr --with- libpq=/apps/ postgres make rm -rf $RPM_BUILD_ROOT umask 0077 mkdir -p $RPM_BUILD_ROOT/usr/local/bin mkdir -p $RPM_BUILD_ROOT...from a source code repository. %pre %prep %setup %build ./autogen.sh ; ./configure --with-db=/apps/db --with-libpq=/apps/ postgres make

  19. 49 CFR 41.110 - New DOT owned buildings and additions to buildings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... architect's authenticated verifications of seismic design codes, standards, and practices used in the design... for the design and construction of new DOT Federally owned buildings will ensure that each building is designed and constructed in accord with the seismic design and construction standards set out in § 41.120...

  20. Joint China-United States Report for Year 1 Insulation Materials and Systems Project Area Clean Energy Research Center Building Energy Efficiency (CERC-BEE)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stovall, Therese K; Biswas, Kaushik; Song, Bo

    In November of 2009, the presidents of China and the U.S. announced the establishment of the Clean Energy Research Center (CERC). This broad research effort is co-funded by both countries and involves a large number of research centers and universities in both countries. One part of this program is focused on improving the energy efficiency of buildings. One portion of the CERC-BEE was focused on building insulation systems. The research objective of this effort was to Identify and investigate candidate high performance fire resistant building insulation technologies that meet the goal of building code compliance for exterior wall applications inmore » green buildings in multiple climate zones. A Joint Work Plan was established between researchers at the China Academy of Building Research and Oak Ridge National Laboratory. Efforts in the first year under this plan focused on information gathering. The objective of this research program is to reduce building energy use in China via improved building insulation technology. In cold regions in China, residents often use inefficient heating systems to provide a minimal comfort level within inefficient buildings. In warmer regions, air conditioning has not been commonly used. As living standards rise, energy consumption in these regions will increase dramatically unless significant improvements are made in building energy performance. Previous efforts that defined the current state of the built environment in China and in the U.S. will be used in this research. In countries around the world, building improvements have typically followed the implementation of more stringent building codes. There have been several changes in building codes in both the U.S. and China within the last few years. New U.S. building codes have increased the amount of wall insulation required in new buildings. New government statements from multiple agencies in China have recently changed the requirements for buildings in terms of energy

  1. Building America Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-11-01

    While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less

  2. Building Needs for the Handicapped.

    ERIC Educational Resources Information Center

    Windham Southeast Supervisory Union, Brattleboro, VT.

    Listed in the document are specific building needs for the handicapped. It is explained that the detailed survey forms can be used to determine building accessibility for a wide range of handicapping conditions. Survey information includes the specific building need (e.g. 12 foot wide parking space) and the letter code for affected function. Space…

  3. A GPL Relativistic Hydrodynamical Code

    NASA Astrophysics Data System (ADS)

    Olvera, D.; Mendoza, S.

    We are currently building a free (in the sense of a GNU GPL license) 2DRHD code in order to be used for different astrophysical situations. Our final target will be to include strong gravitational fields and magnetic fields. We intend to form a large group of developers as it is usually done for GPL codes.

  4. Long-term perspectives on giant earthquakes and tsunamis at subduction zones

    USGS Publications Warehouse

    Satake, K.; Atwater, B.F.; ,

    2007-01-01

    Histories of earthquakes and tsunamis, inferred from geological evidence, aid in anticipating future catastrophes. This natural warning system now influences building codes and tsunami planning in the United States, Canada, and Japan, particularly where geology demonstrates the past occurrence of earthquakes and tsunamis larger than those known from written and instrumental records. Under favorable circumstances, paleoseismology can thus provide long-term advisories of unusually large tsunamis. The extraordinary Indian Ocean tsunami of 2004 resulted from a fault rupture more than 1000 km in length that included and dwarfed fault patches that had broken historically during lesser shocks. Such variation in rupture mode, known from written history at a few subduction zones, is also characteristic of earthquake histories inferred from geology on the Pacific Rim. Copyright ?? 2007 by Annual Reviews. All rights reserved.

  5. Discrete Cosine Transform Image Coding With Sliding Block Codes

    NASA Astrophysics Data System (ADS)

    Divakaran, Ajay; Pearlman, William A.

    1989-11-01

    A transform trellis coding scheme for images is presented. A two dimensional discrete cosine transform is applied to the image followed by a search on a trellis structured code. This code is a sliding block code that utilizes a constrained size reproduction alphabet. The image is divided into blocks by the transform coding. The non-stationarity of the image is counteracted by grouping these blocks in clusters through a clustering algorithm, and then encoding the clusters separately. Mandela ordered sequences are formed from each cluster i.e identically indexed coefficients from each block are grouped together to form one dimensional sequences. A separate search ensues on each of these Mandela ordered sequences. Padding sequences are used to improve the trellis search fidelity. The padding sequences absorb the error caused by the building up of the trellis to full size. The simulations were carried out on a 256x256 image ('LENA'). The results are comparable to any existing scheme. The visual quality of the image is enhanced considerably by the padding and clustering.

  6. 28 CFR 36.607 - Guidance concerning model codes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 1 2013-07-01 2013-07-01 false Guidance concerning model codes. 36.607... BY PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.607 Guidance concerning model codes. Upon application by an authorized representative of a...

  7. 28 CFR 36.607 - Guidance concerning model codes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 1 2014-07-01 2014-07-01 false Guidance concerning model codes. 36.607... BY PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.607 Guidance concerning model codes. Upon application by an authorized representative of a...

  8. 28 CFR 36.607 - Guidance concerning model codes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 1 2012-07-01 2012-07-01 false Guidance concerning model codes. 36.607... BY PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.607 Guidance concerning model codes. Upon application by an authorized representative of a...

  9. 28 CFR 36.607 - Guidance concerning model codes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 1 2011-07-01 2011-07-01 false Guidance concerning model codes. 36.607... BY PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.607 Guidance concerning model codes. Upon application by an authorized representative of a...

  10. Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birru, Dagnachew; Wen, Yao-Jung; Rubinstein, Francis M.

    2013-10-28

    the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of

  11. Building application of solar energy. Study no. 2: Representative buildings for solar energy performance analysis and market penetration

    NASA Technical Reports Server (NTRS)

    Hirshberg, A. S.

    1975-01-01

    The following topics are discussed: (1) Assignment of population to microclimatic zones; (2) specifications of the mix of buildings in the SCE territory; (3) specification of four typical buildings for thermal analysis and market penetration studies; (4) identification of the materials and energy conserving characteristics of these typical buildings; (5) specifications of the HVAC functions used in each typical building, and determination of the HVAC systems used in each building; and (6) identification of the type of fuel used in each building.

  12. Wood: a construction material for tall buildings

    NASA Astrophysics Data System (ADS)

    Wimmers, Guido

    2017-12-01

    Wood has great potential as a building material, because it is strong and lightweight, environmentally friendly and can be used in prefabricated buildings. However, only changes in building codes will make wood competitive with steel and concrete.

  13. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  14. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  15. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  16. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  17. Performance and Application of Parallel OVERFLOW Codes on Distributed and Shared Memory Platforms

    NASA Technical Reports Server (NTRS)

    Djomehri, M. Jahed; Rizk, Yehia M.

    1999-01-01

    The presentation discusses recent studies on the performance of the two parallel versions of the aerodynamics CFD code, OVERFLOW_MPI and _MLP. Developed at NASA Ames, the serial version, OVERFLOW, is a multidimensional Navier-Stokes flow solver based on overset (Chimera) grid technology. The code has recently been parallelized in two ways. One is based on the explicit message-passing interface (MPI) across processors and uses the _MPI communication package. This approach is primarily suited for distributed memory systems and workstation clusters. The second, termed the multi-level parallel (MLP) method, is simple and uses shared memory for all communications. The _MLP code is suitable on distributed-shared memory systems. For both methods, the message passing takes place across the processors or processes at the advancement of each time step. This procedure is, in effect, the Chimera boundary conditions update, which is done in an explicit "Jacobi" style. In contrast, the update in the serial code is done in more of the "Gauss-Sidel" fashion. The programming efforts for the _MPI code is more complicated than for the _MLP code; the former requires modification of the outer and some inner shells of the serial code, whereas the latter focuses only on the outer shell of the code. The _MPI version offers a great deal of flexibility in distributing grid zones across a specified number of processors in order to achieve load balancing. The approach is capable of partitioning zones across multiple processors or sending each zone and/or cluster of several zones into a single processor. The message passing across the processors consists of Chimera boundary and/or an overlap of "halo" boundary points for each partitioned zone. The MLP version is a new coarse-grain parallel concept at the zonal and intra-zonal levels. A grouping strategy is used to distribute zones into several groups forming sub-processes which will run in parallel. The total volume of grid points in each

  18. Construction of Architectural Structures in Cultural Heritage Protection Zones

    NASA Astrophysics Data System (ADS)

    Zagroba, Marek; Gawryluk, Dorota

    2017-10-01

    The article raises issues of constructing contemporary architectural structures in cultural heritage protection zones, using the case study of a building located within the campus of the University of Warmia and Mazury in Olsztyn, Poland. Questions revolving around the construction of this building arise from the need to preserve the surrounding historic heritage, and deal with landscaping, architectural and construction solutions as well as interior design. All these problems grow in importance when dealing with such unique buildings like the discussed example of a laboratory building for the Civil Engineering Department, built on a site within a conservation zone of the university campus. The specific character of the building and the specialist equipment with which it was to be furnished (a resistance testing machine, a 17-meter-long wave flume) necessitated a series of analyses. In turn, the fact that the new building was to be erected in the conservation zone meant that collaboration with the Heritage Conservation Office had to be undertaken at the stage of making the plan and continued during the construction works. The Heritage Officer’s recommendations concerning the building’s shape, divisions, dimensions, materials used, etc., created a situation where the team of designers and architects had to become engaged in the process of landscape and spatial management. The above requirements concerned the functions of the building and its siting on a land parcel that was difficult to handle, also because of the protected trees growing there. Other constraints included the small size of this site, the developed surroundings, and the pre-defined programme of functions and use of the new building. All the above circumstances made the task difficult and demanded good coordination between individual teams of engineers and architects, both at the stage of making the plan and during the construction works. Many of the heritage protection zones are spoilt with

  19. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505.1...

  20. Deductive Glue Code Synthesis for Embedded Software Systems Based on Code Patterns

    NASA Technical Reports Server (NTRS)

    Liu, Jian; Fu, Jicheng; Zhang, Yansheng; Bastani, Farokh; Yen, I-Ling; Tai, Ann; Chau, Savio N.

    2006-01-01

    Automated code synthesis is a constructive process that can be used to generate programs from specifications. It can, thus, greatly reduce the software development cost and time. The use of formal code synthesis approach for software generation further increases the dependability of the system. Though code synthesis has many potential benefits, the synthesis techniques are still limited. Meanwhile, components are widely used in embedded system development. Applying code synthesis to component based software development (CBSD) process can greatly enhance the capability of code synthesis while reducing the component composition efforts. In this paper, we discuss the issues and techniques for applying deductive code synthesis techniques to CBSD. For deductive synthesis in CBSD, a rule base is the key for inferring appropriate component composition. We use the code patterns to guide the development of rules. Code patterns have been proposed to capture the typical usages of the components. Several general composition operations have been identified to facilitate systematic composition. We present the technique for rule development and automated generation of new patterns from existing code patterns. A case study of using this method in building a real-time control system is also presented.

  1. Error-correction coding for digital communications

    NASA Astrophysics Data System (ADS)

    Clark, G. C., Jr.; Cain, J. B.

    This book is written for the design engineer who must build the coding and decoding equipment and for the communication system engineer who must incorporate this equipment into a system. It is also suitable as a senior-level or first-year graduate text for an introductory one-semester course in coding theory. Fundamental concepts of coding are discussed along with group codes, taking into account basic principles, practical constraints, performance computations, coding bounds, generalized parity check codes, polynomial codes, and important classes of group codes. Other topics explored are related to simple nonalgebraic decoding techniques for group codes, soft decision decoding of block codes, algebraic techniques for multiple error correction, the convolutional code structure and Viterbi decoding, syndrome decoding techniques, and sequential decoding techniques. System applications are also considered, giving attention to concatenated codes, coding for the white Gaussian noise channel, interleaver structures for coded systems, and coding for burst noise channels.

  2. Building Energy Efficiency in Rural China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Meredydd; Yu, Sha; Song, Bo

    2014-04-01

    Rural buildings in China now account for more than half of China’s total building energy use. Forty percent of the floorspace in China is in rural villages and towns. Most of these buildings are very energy inefficient, and may struggle to meet basic needs. They are cold in the winter, and often experience indoor air pollution from fuel use. The Chinese government plans to adopt a voluntary building energy code, or design standard, for rural homes. The goal is to build on China’s success with codes in urban areas to improve efficiency and comfort in rural homes. The Chinese governmentmore » recognizes rural buildings represent a major opportunity for improving national building energy efficiency. The challenges of rural China are also greater than those of urban areas in many ways because of the limited local capacity and low income levels. The Chinese government wants to expand on new programs to subsidize energy efficiency improvements in rural homes to build capacity for larger-scale improvement. This article summarizes the trends and status of rural building energy use in China. It then provides an overview of the new rural building design standard, and describes options and issues to move forward with implementation.« less

  3. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Idaho. Moving to the 2015 IECC from the 2015 Idaho State Code base code is cost-effective for residential buildings in all climate zones in Idaho.

  4. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Iowa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Iowa. Moving to the 2015 IECC from the 2014 Iowa State Code base code is cost-effective for residential buildings in all climate zones in Iowa.

  5. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Utah

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Utah. Moving to the 2015 IECC from the 2012 Utah State Code base code is cost-effective for residential buildings in all climate zones in Utah.

  6. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Montana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Montana. Moving to the 2015 IECC from the 2014 Montana State Code base code is cost-effective for residential buildings in all climate zones in Montana.

  7. Building Thermal Models

    NASA Technical Reports Server (NTRS)

    Peabody, Hume L.

    2017-01-01

    This presentation is meant to be an overview of the model building process It is based on typical techniques (Monte Carlo Ray Tracing for radiation exchange, Lumped Parameter, Finite Difference for thermal solution) used by the aerospace industry This is not intended to be a "How to Use ThermalDesktop" course. It is intended to be a "How to Build Thermal Models" course and the techniques will be demonstrated using the capabilities of ThermalDesktop (TD). Other codes may or may not have similar capabilities. The General Model Building Process can be broken into four top level steps: 1. Build Model; 2. Check Model; 3. Execute Model; 4. Verify Results.

  8. City Reach Code Technical Support Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Athalye, Rahul A.; Chen, Yan; Zhang, Jian

    This report describes and analyzes a set of energy efficiency measures that will save 20% energy over ASHRAE Standard 90.1-2013. The measures will be used to formulate a Reach Code for cities aiming to go beyond national model energy codes. A coalition of U.S. cities together with other stakeholders wanted to facilitate the development of voluntary guidelines and standards that can be implemented in stages at the city level to improve building energy efficiency. The coalition's efforts are being supported by the U.S. Department of Energy via Pacific Northwest National Laboratory (PNNL) and in collaboration with the New Buildings Institute.

  9. High dynamic range coding imaging system

    NASA Astrophysics Data System (ADS)

    Wu, Renfan; Huang, Yifan; Hou, Guangqi

    2014-10-01

    We present a high dynamic range (HDR) imaging system design scheme based on coded aperture technique. This scheme can help us obtain HDR images which have extended depth of field. We adopt Sparse coding algorithm to design coded patterns. Then we utilize the sensor unit to acquire coded images under different exposure settings. With the guide of the multiple exposure parameters, a series of low dynamic range (LDR) coded images are reconstructed. We use some existing algorithms to fuse and display a HDR image by those LDR images. We build an optical simulation model and get some simulation images to verify the novel system.

  10. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  11. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  12. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  13. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  14. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  15. Resolution Study of Marine CSEM Imaging of Subduction Zones

    NASA Astrophysics Data System (ADS)

    Gustafson, C.; Key, K.

    2016-12-01

    Marine controlled source electromagnetic (CSEM) data allow us to image seafloor electrical resistivity from which we can constrain the porosity and fluid content of the subsurface. In subduction zones, CSEM data can be used to constrain geologic structure, hydrogeology and fluid-tectonic processes. The scales of features we are interested in recovering with CSEM data range from large-scale features such as the incoming tectonic plate and subducting slab, to the narrow dipping plate boundary interface where slip occurs, to thin faults that cut the overriding forearc crust and shallow fluid seeps and mounds on the seafloor. Thus electrical structure is expected to vary on scales ranging from scales of meters to tens of kilometers. CSEM data collected by Scripps at the Middle America Trench in 2010 is the first and to-date the only application of the method for studying a subduction zone. The results from this pioneering data set highlight the types of new discoveries that are possible with CSEM data, such as imaging conductive bending faults and a water-rich channel of subducting sediments. In this work we explore the magnitude and scale of 2D resistivity structures that can be resolved with CSEM data through a suite of synthetic inversion studies. We build resistivity models that are representative of various known and hypothesized subduction zone plate boundary structures. We generate synthetic noisy data for these models and invert them using the freely available MARE2DEM inversion code. We compare the recovered models to the original models in order to determine which resistivity structures may be successfully identified using CSEM. We explore the potential effects of receiver spacing, frequency bandwidth and system noise levels on the ability of CSEM to recover these different subduction zone structures.

  16. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for New Hampshire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in New Hampshire. Moving to the 2015 IECC from the 2010 New Hampshire State Code base code is cost-effective for residential buildings in all climate zones in New Hampshire.

  17. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for North Carolina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in North Carolina. Moving to the 2015 IECC from the 2012 North Carolina State Code base code is cost-effective for residential buildings in all climate zones in North Carolina.

  18. Overview of the ArbiTER edge plasma eigenvalue code

    NASA Astrophysics Data System (ADS)

    Baver, Derek; Myra, James; Umansky, Maxim

    2011-10-01

    The Arbitrary Topology Equation Reader, or ArbiTER, is a flexible eigenvalue solver that is currently under development for plasma physics applications. The ArbiTER code builds on the equation parser framework of the existing 2DX code, extending it to include a topology parser. This will give the code the capability to model problems with complicated geometries (such as multiple X-points and scrape-off layers) or model equations with arbitrary numbers of dimensions (e.g. for kinetic analysis). In the equation parser framework, model equations are not included in the program's source code. Instead, an input file contains instructions for building a matrix from profile functions and elementary differential operators. The program then executes these instructions in a sequential manner. These instructions may also be translated into analytic form, thus giving the code transparency as well as flexibility. We will present an overview of how the ArbiTER code is to work, as well as preliminary results from early versions of this code. Work supported by the U.S. DOE.

  19. A Data Parallel Multizone Navier-Stokes Code

    NASA Technical Reports Server (NTRS)

    Jespersen, Dennis C.; Levit, Creon; Kwak, Dochan (Technical Monitor)

    1995-01-01

    We have developed a data parallel multizone compressible Navier-Stokes code on the Connection Machine CM-5. The code is set up for implicit time-stepping on single or multiple structured grids. For multiple grids and geometrically complex problems, we follow the "chimera" approach, where flow data on one zone is interpolated onto another in the region of overlap. We will describe our design philosophy and give some timing results for the current code. The design choices can be summarized as: 1. finite differences on structured grids; 2. implicit time-stepping with either distributed solves or data motion and local solves; 3. sequential stepping through multiple zones with interzone data transfer via a distributed data structure. We have implemented these ideas on the CM-5 using CMF (Connection Machine Fortran), a data parallel language which combines elements of Fortran 90 and certain extensions, and which bears a strong similarity to High Performance Fortran (HPF). One interesting feature is the issue of turbulence modeling, where the architecture of a parallel machine makes the use of an algebraic turbulence model awkward, whereas models based on transport equations are more natural. We will present some performance figures for the code on the CM-5, and consider the issues involved in transitioning the code to HPF for portability to other parallel platforms.

  20. Are building-level characteristics associated with indoor allergens in the household?

    PubMed

    Rosenfeld, Lindsay; Chew, Ginger L; Rudd, Rima; Emmons, Karen; Acosta, Luis; Perzanowski, Matt; Acevedo-García, Dolores

    2011-02-01

    Building-level characteristics are structural factors largely beyond the control of those who live in them. We explored whether building-level characteristics and indoor allergens in the household are related. We examined the relationship between building-level characteristics and indoor allergens: dust mite, cat, cockroach, and mouse. Building-level characteristics measured were presence of pests (seeing cockroaches and rodents), building type (public housing, buildings zoned commercially and residentially, and building size), and building condition (building age and violations). Allergen cutpoints were used for categorical analyses and defined as follows: dust mite: >0.25 μg/g; cat: >1 μg/g; cockroach: >1 U/g; mouse: >1.6 μg/g. In fully adjusted linear analyses, neither dust mite nor cat allergen were statistically significantly associated with any building-level characteristics. Cockroach allergen was associated with the presence of cockroaches (2.07; 95% CI, 1.23, 3.49) and living in public housing (2.14; 95% CI, 1.07, 4.31). Mouse allergen was associated with the presence of rodents (1.70; 95% CI, 1.29, 2.23), and building size: living in a low-rise (<8 floors; 0.60; 95% CI, 0.42, 0.87) or high-rise (8 + floors; 0.50; 95% CI, 0.29, 0.88; compared with house/duplex). In fully adjusted logistic analyses, cat allergen was statistically significantly associated with living in a high-rise (6.29; 95% CI, 1.51, 26.21; compared with a house/duplex). Mouse allergen was associated with living in public housing (6.20; 95% CI, 1.01, 37.95) and building size: living in a low-rise (0.16; 95% CI, 0.05, 0.52) or high-rise (0.06; 95% CI, 0.01, 0.50; compared with a house/duplex). Issues concerning building size and public housing may be particularly critical factors in reducing asthma morbidity. We suggest that future research explore the possible improvement of these factors through changes to building code and violations adherence, design standards, and incentives for

  1. Individual and Sex Differences in the Zone of Acceptable Alternatives.

    ERIC Educational Resources Information Center

    Leung, S. Alvin; Harmon, Lenore W.

    1990-01-01

    Examined zone of acceptable alternatives construct from Gottfredson's theory of career aspiration. College students' (N=246) responses to Occupations List were coded with measurements of sex type and prestige, and indicators of zone of acceptable alternatives for subjects' were computed. Found changes over time and differences related to gender…

  2. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  3. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  4. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  5. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  6. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  7. ATLAS software configuration and build tool optimisation

    NASA Astrophysics Data System (ADS)

    Rybkin, Grigory; Atlas Collaboration

    2014-06-01

    ATLAS software code base is over 6 million lines organised in about 2000 packages. It makes use of some 100 external software packages, is developed by more than 400 developers and used by more than 2500 physicists from over 200 universities and laboratories in 6 continents. To meet the challenge of configuration and building of this software, the Configuration Management Tool (CMT) is used. CMT expects each package to describe its build targets, build and environment setup parameters, dependencies on other packages in a text file called requirements, and each project (group of packages) to describe its policies and dependencies on other projects in a text project file. Based on the effective set of configuration parameters read from the requirements files of dependent packages and project files, CMT commands build the packages, generate the environment for their use, or query the packages. The main focus was on build time performance that was optimised within several approaches: reduction of the number of reads of requirements files that are now read once per package by a CMT build command that generates cached requirements files for subsequent CMT build commands; introduction of more fine-grained build parallelism at package task level, i.e., dependent applications and libraries are compiled in parallel; code optimisation of CMT commands used for build; introduction of package level build parallelism, i. e., parallelise the build of independent packages. By default, CMT launches NUMBER-OF-PROCESSORS build commands in parallel. The other focus was on CMT commands optimisation in general that made them approximately 2 times faster. CMT can generate a cached requirements file for the environment setup command, which is especially useful for deployment on distributed file systems like AFS or CERN VMFS. The use of parallelism, caching and code optimisation significantly-by several times-reduced software build time, environment setup time, increased the efficiency of

  8. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for the District of Columbia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in the District of Columbia. Moving to the 2015 IECC from the 2013 Washington DC Code base code is cost-effective for residential buildings in all climate zones in the District of Columbia.

  9. Computation of Acoustic Waves Through Sliding-Zone Interfaces Using an Euler/Navier-Stokes Code

    NASA Technical Reports Server (NTRS)

    Rumsey, Christopher L.

    1996-01-01

    The effect of a patched sliding-zone interface on the transmission of acoustic waves is examined for two- and three-dimensional model problems. A simple but general interpolation scheme at the patched boundary passes acoustic waves without distortion, provided that a sufficiently small time step is taken. A guideline is provided for the maximum permissible time step or zone speed that gives an acceptable error introduced by the sliding-zone interface.

  10. Vapor Intrusion Estimation Tool for Unsaturated Zone Contaminant Sources. User’s Guide

    DTIC Science & Technology

    2016-08-30

    324449 Page Intentionally Left Blank iii Executive Summary Soil vapor extraction (SVE) is a prevalent remediation approach for volatile contaminants...strength and location, vadose zone transport, and a model for estimating movement of soil -gas vapor contamination into buildings. The tool may be...framework for estimating the impact of a vadose zone contaminant source on soil gas concentrations and vapor intrusion into a building

  11. Analysis of quantum error-correcting codes: Symplectic lattice codes and toric codes

    NASA Astrophysics Data System (ADS)

    Harrington, James William

    Quantum information theory is concerned with identifying how quantum mechanical resources (such as entangled quantum states) can be utilized for a number of information processing tasks, including data storage, computation, communication, and cryptography. Efficient quantum algorithms and protocols have been developed for performing some tasks (e.g. , factoring large numbers, securely communicating over a public channel, and simulating quantum mechanical systems) that appear to be very difficult with just classical resources. In addition to identifying the separation between classical and quantum computational power, much of the theoretical focus in this field over the last decade has been concerned with finding novel ways of encoding quantum information that are robust against errors, which is an important step toward building practical quantum information processing devices. In this thesis I present some results on the quantum error-correcting properties of oscillator codes (also described as symplectic lattice codes) and toric codes. Any harmonic oscillator system (such as a mode of light) can be encoded with quantum information via symplectic lattice codes that are robust against shifts in the system's continuous quantum variables. I show the existence of lattice codes whose achievable rates match the one-shot coherent information over the Gaussian quantum channel. Also, I construct a family of symplectic self-dual lattices and search for optimal encodings of quantum information distributed between several oscillators. Toric codes provide encodings of quantum information into two-dimensional spin lattices that are robust against local clusters of errors and which require only local quantum operations for error correction. Numerical simulations of this system under various error models provide a calculation of the accuracy threshold for quantum memory using toric codes, which can be related to phase transitions in certain condensed matter models. I also present

  12. Work zone positive protection guidelines for Idaho.

    DOT National Transportation Integrated Search

    2014-12-01

    The Code of Federal Regulation (CFR) Title 23 Part 630 Subpart K - Temporary Traffic Control (630.1102630.1110) rule states : that positive protection shall be considered where work zone conditions place workers at increased risk from motorized : ...

  13. Implementing newborn mock codes.

    PubMed

    Blakely, Teresa Gail

    2007-01-01

    This article describes the implementation of a newborn mock code program. Although the Neonatal Resuscitation Program (NRP) is one of the most widely used health education programs in the world and is required for most hospital providers who attend deliveries, research tells us that retention of NRP skills deteriorates rapidly after completion of the course. NRP requires coordination and cooperation among all providers; however, a lack of leadership and teamwork during resuscitation (often associated with a lack of confidence) has been noted. Implementation of newborn mock code scenarios can encourage teamwork, communication, skills building, and increased confidence levels of providers. Mock codes can help providers become strong team members and team leaders by helping them be better prepared for serious situations in the delivery room. Implementation of newborn mock codes can be effectively accomplished with appropriate planning and consideration for adult learning behaviors.

  14. 1. VIEW, LOOKING NORTH, OF THE SOUTH ELEVATION OF BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW, LOOKING NORTH, OF THE SOUTH ELEVATION OF BUILDING 901. BUILDING 901 IS ONE OF FOUR GUARD TOWERS INSTALLED AS PART OF THE PERIMETER SECURITY ZONE TO PROVIDE PROTECTIVE FORCE PERSONNEL WITH A CLEAR HIGH VIEW OF THE SURROUNDING AREAS. THE PERIMETER SECURITY ZONE CONSISTS OF A DOUBLE PERIMETER FENCE WITH CLOSED CIRCUIT TELEVISIONS, ALARMS, AND AN UNINTERRUPTED POWER SUPPLY. - Rocky Flats Plant, Guard Tower, Southeast corner of protected area, Golden, Jefferson County, CO

  15. Cost optimization for buildings with hybrid ventilation systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji, Kun; Lu, Yan

    A method including: computing a total cost for a first zone in a building, wherein the total cost is equal to an actual energy cost of the first zone plus a thermal discomfort cost of the first zone; and heuristically optimizing the total cost to identify temperature setpoints for a mechanical heating/cooling system and a start time and an end time of the mechanical heating/cooling system, based on external weather data and occupancy data of the first zone.

  16. Nonlinear analysis of r.c. framed buildings retrofitted with elastomeric and friction bearings under near-fault earthquakes

    NASA Astrophysics Data System (ADS)

    Mazza, Mirko

    2015-12-01

    Reinforced concrete (r.c.) framed buildings designed in compliance with inadequate seismic classifications and code provisions present in many cases a high vulnerability and need to be retrofitted. To this end, the insertion of a base isolation system allows a considerable reduction of the seismic loads transmitted to the superstructure. However, strong near-fault ground motions, which are characterised by long-duration horizontal pulses, may amplify the inelastic response of the superstructure and induce a failure of the isolation system. The above considerations point out the importance of checking the effectiveness of different isolation systems for retrofitting a r.c. framed structure. For this purpose, a numerical investigation is carried out with reference to a six-storey r.c. framed building, which, primarily designed (as to be a fixed-base one) in compliance with the previous Italian code (DM96) for a medium-risk seismic zone, has to be retrofitted by insertion of an isolation system at the base for attaining performance levels imposed by the current Italian code (NTC08) in a high-risk seismic zone. Besides the (fixed-base) original structure, three cases of base isolation are studied: elastomeric bearings acting alone (e.g. HDLRBs); in-parallel combination of elastomeric and friction bearings (e.g. high-damping-laminated-rubber bearings, HDLRBs and steel-PTFE sliding bearings, SBs); friction bearings acting alone (e.g. friction pendulum bearings, FPBs). The nonlinear analysis of the fixed-base and base-isolated structures subjected to horizontal components of near-fault ground motions is performed for checking plastic conditions at the potential critical (end) sections of the girders and columns as well as critical conditions of the isolation systems. Unexpected high values of ductility demand are highlighted at the lower floors of all base-isolated structures, while re-centring problems of the base isolation systems under near-fault earthquakes are

  17. Atomistic Cohesive Zone Models for Interface Decohesion in Metals

    NASA Technical Reports Server (NTRS)

    Yamakov, Vesselin I.; Saether, Erik; Glaessgen, Edward H.

    2009-01-01

    Using a statistical mechanics approach, a cohesive-zone law in the form of a traction-displacement constitutive relationship characterizing the load transfer across the plane of a growing edge crack is extracted from atomistic simulations for use within a continuum finite element model. The methodology for the atomistic derivation of a cohesive-zone law is presented. This procedure can be implemented to build cohesive-zone finite element models for simulating fracture in nanocrystalline or ultrafine grained materials.

  18. Mechanical characterization of natural building stones: observation of the fracture process zone by ESPI

    NASA Astrophysics Data System (ADS)

    Calvetti, Francesco; Cardani, Giuliana; Meda, Alberto

    1999-09-01

    The cultural heritage of many nations consist of a great variety of structures of high intrinsic value, which are often composed of natural building stones (NBS), as granite, limestone, marble and sandstone. The use of accurate inspection devices, such as laser interferometry, allows us to acquire information regarding the mechanical properties and damage (tensile cracks) of NBS, which represents the first step in the restoration process. In this paper, the potential application of an electronic speckle pattern interferometry (ESPI) is shown, with particular attention to the observed displacement field and the crack penetration during laboratory testing. In ESPI, by superimposing a reflected light to a reference digitized image, an interference phenomenon is produced. By comparing two recorded interference patterns (before and after loading), the corresponding deformation can be evaluated. The application of ESPI in several laboratory tests on NBS is presented in this paper. In particular, during bending tests performed on geometrically similar NBS specimens, it was observed that the size and shape of the localized damage zone do not depend on the specimen size. These results allow for an interpretation of the 'size- effect,' which consists of a reduction of nominal strength as the specimen size increases.

  19. Effect of strong-column weak-beam design provision on the seismic fragility of RC frame buildings

    NASA Astrophysics Data System (ADS)

    Surana, Mitesh; Singh, Yogendra; Lang, Dominik H.

    2018-04-01

    Incremental dynamic analyses are conducted for a suite of low- and mid-rise reinforced-concrete special moment-resisting frame buildings. Buildings non-conforming and conforming to the strong-column weak-beam (SCWB) design criterion are considered. These buildings are designed for the two most severe seismic zones in India (i.e., zone IV and zone V) following the provisions of Indian Standards. It is observed that buildings non-conforming to the SCWB design criterion lead to an undesirable column failure collapse mechanism. Although yielding of columns cannot be avoided, even for buildings conforming to a SCWB ratio of 1.4, the observed collapse mechanism changes to a beam failure mechanism. This change in collapse mechanism leads to a significant increase in the building's global ductility capacity, and thereby in collapse capacity. The fragility analysis study of the considered buildings suggests that considering the SCWB design criterion leads to a significant reduction in collapse probability, particularly in the case of mid-rise buildings.

  20. Controlling Energy Consumption in Single Buildings.

    DTIC Science & Technology

    1982-07-01

    Asphalt shingles Apartment 1/2" plywood sheathing; 2"x4 ൦% sidewalls; 0% 1/2" plywood Building stud framing (16" c.c.); 2- endwalls. sheathing,3-1/2...cycling does produce additional wear on belts and motor starting circuits. Further, it may affect building air balance between building zones if more...4" common brick; 1/2" Single-strenght sheet; Asphalt shingles; Apartment plywood shetthing; light 30% sidewalls; 0% 1/2" plywood Buiiding framing; no

  1. 1. VIEW, LOOKING SOUTH, OF THE NORTH ELEVATION OF BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW, LOOKING SOUTH, OF THE NORTH ELEVATION OF BUILDING 792A. BUILDING 792A, AT PORTAL 3, IS ONE OF THREE PEDESTRIAN ACCESS POINTS THROUGH THE PERIMETER SECURITY ZONE INTO THE PROTECTED AREA. - Rocky Flats Plant, Access Control Building, North of building 771, in parking area 71, just south of North Perimeter Road, Golden, Jefferson County, CO

  2. 10 CFR 434.99 - Explanation of numbering system for codes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Explanation of numbering system for codes. 434.99 Section 434.99 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS § 434.99 Explanation of numbering system for codes. (a) For...

  3. 10 CFR 434.99 - Explanation of numbering system for codes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Explanation of numbering system for codes. 434.99 Section 434.99 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS § 434.99 Explanation of numbering system for codes. (a) For...

  4. THE INTEGRATION OF A PROPOSED ZONE CLOSURE APPROACH FOR THE PLUTONIUM FINISHING PLANT (PFP) DECOMMISSIONING & THE PFP ZONE HANFORD SITE WASHINGTON

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HOPKINS, A.M.

    2005-02-23

    The Plutonium Finishing Plant (PFP) and associated processing facilities are located in the 200 area of the Hanford Site in Eastern Washington. This area is part of what is now called the Central Plateau. In order to achieve closure of the contaminated facilities and waste sites at Hanford on the Central Plateau (CP), a geographic re-districting of the area into zones has been proposed in the recently published Plan for Central Plateau Closure. One of the 22 zones proposed in the Central Plateau encompasses the PFP and ancillary facilities. Approximately eighty six buildings are included in the PFP Zone. Thismore » paper addresses the approach for the closure of the PFP Zone within the Central Plateau. The PFP complex of buildings forms the bulk of the structures in the PFP Zone. For closure of the above-grade portion of structures within the PFP complex, the approach is to remove them to a state called ''slab-on-grade'' per the criteria contained in PFP End Point Criteria document and as documented in action memoranda. For below-grade portions of the structures (such as below-grade rooms, pipe trenches and underground ducts), the approach is to remove as much residual contamination as practicable and to fill the void spaces with clean fill material such as sand, grout, or controlled density fill. This approach will be modified as planning for the waste sites progresses to ensure that the actions of the PFP decommissioning projects do not negatively impact future planned actions under the CERCLA. Cribs, settling tanks, septic tanks and other miscellaneous below-grade void spaces will either be cleaned to the extent practicable and filled or will be covered with an environmental barrier as determined by further studies and CERCLA decision documents. Currently, between two and five environmental barriers are proposed to be placed over waste sites and remaining building slabs in the PFP Zone.« less

  5. 10 CFR 434.516 - Building exterior envelope.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Prototype and Reference Buildings, the infiltration assumptions in subsection 516.2.1 shall be prescribed.... Infiltration shall impact perimeter zones only. 516.2.1When the HVAC system is switched “on,” no infiltration shall be assumed. When the HVAC system is switched “off,” the infiltration rate for buildings with or...

  6. 10 CFR 434.516 - Building exterior envelope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Prototype and Reference Buildings, the infiltration assumptions in subsection 516.2.1 shall be prescribed.... Infiltration shall impact perimeter zones only. 516.2.1When the HVAC system is switched “on,” no infiltration shall be assumed. When the HVAC system is switched “off,” the infiltration rate for buildings with or...

  7. 10 CFR 434.516 - Building exterior envelope.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Prototype and Reference Buildings, the infiltration assumptions in subsection 516.2.1 shall be prescribed.... Infiltration shall impact perimeter zones only. 516.2.1When the HVAC system is switched “on,” no infiltration shall be assumed. When the HVAC system is switched “off,” the infiltration rate for buildings with or...

  8. 10 CFR 434.516 - Building exterior envelope.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Prototype and Reference Buildings, the infiltration assumptions in subsection 516.2.1 shall be prescribed.... Infiltration shall impact perimeter zones only. 516.2.1When the HVAC system is switched “on,” no infiltration shall be assumed. When the HVAC system is switched “off,” the infiltration rate for buildings with or...

  9. Infill Walls Contribution on the Progressive Collapse Resistance of a Typical Mid-rise RC Framed Building

    NASA Astrophysics Data System (ADS)

    Besoiu, Teodora; Popa, Anca

    2017-10-01

    This study investigates the effect of the autoclaved aerated concrete infill walls on the progressive collapse resistance of a typical RC framed structure. The 13-storey building located in Brăila (a zone with high seismic risk in Romania) was designed according to the former Romanian seismic code P13-70 (1970). Two models of the structure are generated in the Extreme Loading® for Structures computer software: a model with infill walls and a model without infill walls. Following GSA (2003) Guidelines, a nonlinear dynamic procedure is used to determine the progressive collapse risk of the building when a first-storey corner column is suddenly removed. It was found that, the structure is not expected to fail under the standard GSA loading: DL+0.25LL. Moreover, if the infill walls are introduced in the model, the maximum vertical displacement of the node above the removed column is reduced by about 48%.

  10. How to Build MCNP 6.2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bull, Jeffrey S.

    This presentation describes how to build MCNP 6.2. MCNP®* 6.2 can be compiled on Macs, PCs, and most Linux systems. It can also be built for parallel execution using both OpenMP and Messing Passing Interface (MPI) methods. MCNP6 requires Fortran, C, and C++ compilers to build the code.

  11. 49 CFR 41.119 - DOT regulated buildings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... compliance may include the engineer's and architect's authenticated verification of seismic design codes... and additions to existing buildings will ensure that each DOT regulated building is designed and constructed in accord with seismic design and construction standards as provided by this part. (b) This...

  12. Downscaling NASA Climatological Data to Produce Detailed Climate Zone Maps

    NASA Technical Reports Server (NTRS)

    Chandler, William S.; Hoell, James M.; Westberg, David J.; Whitlock, Charles H.; Zhang, Taiping; Stackhouse, P. W.

    2011-01-01

    The design of energy efficient sustainable buildings is heavily dependent on accurate long-term and near real-time local weather data. To varying degrees the current meteorological networks over the globe have been used to provide these data albeit often from sites far removed from the desired location. The national need is for access to weather and solar resource data accurate enough to use to develop preliminary building designs within a short proposal time limit, usually within 60 days. The NASA Prediction Of Worldwide Energy Resource (POWER) project was established by NASA to provide industry friendly access to globally distributed solar and meteorological data. As a result, the POWER web site (power.larc.nasa.gov) now provides global information on many renewable energy parameters and several buildings-related items but at a relatively coarse resolution. This paper describes a method of downscaling NASA atmospheric assimilation model results to higher resolution and maps those parameters to produce building climate zone maps using estimates of temperature and precipitation. The distribution of climate zones for North America with an emphasis on the Pacific Northwest for just one year shows very good correspondence to the currently defined distribution. The method has the potential to provide a consistent procedure for deriving climate zone information on a global basis that can be assessed for variability and updated more regularly.

  13. Genetic code, hamming distance and stochastic matrices.

    PubMed

    He, Matthew X; Petoukhov, Sergei V; Ricci, Paolo E

    2004-09-01

    In this paper we use the Gray code representation of the genetic code C=00, U=10, G=11 and A=01 (C pairs with G, A pairs with U) to generate a sequence of genetic code-based matrices. In connection with these code-based matrices, we use the Hamming distance to generate a sequence of numerical matrices. We then further investigate the properties of the numerical matrices and show that they are doubly stochastic and symmetric. We determine the frequency distributions of the Hamming distances, building blocks of the matrices, decomposition and iterations of matrices. We present an explicit decomposition formula for the genetic code-based matrix in terms of permutation matrices, which provides a hypercube representation of the genetic code. It is also observed that there is a Hamiltonian cycle in a genetic code-based hypercube.

  14. USDA Plant Hardiness Zone Map

    Science.gov Websites

    those with slower Internet access. Users may also simply type in a ZIP Code and find the hardiness zone : Find Javascript is not enabled in this Internet Browser For a better experience throughout this web site, please enable Javascript in your Internet Browser What is a Captcha and why am I seeing one (on

  15. Jackson Park Hospital Green Building Medical Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    William Dorsey; Nelson Vasquez

    2010-03-31

    Jackson Park Hospital completed the construction of a new Medical Office Building on its campus this spring. The new building construction has adopted the City of Chicago's recent focus on protecting the environment, and conserving energy and resources, with the introduction of green building codes. Located in a poor, inner city neighborhood on the South side of Chicago, Jackson Park Hospital has chosen green building strategies to help make the area a better place to live and work. The new green building houses the hospital's Family Medicine Residency Program and Specialty Medical Offices. The residency program has been vital inmore » attracting new, young physicians to this medically underserved area. The new outpatient center will also help to allure needed medical providers to the community. The facility also has areas designated to women's health and community education. The Community Education Conference Room will provide learning opportunities to area residents. Emphasis will be placed on conserving resources and protecting our environment, as well as providing information on healthcare access and preventive medicine. The new Medical Office Building was constructed with numerous energy saving features. The exterior cladding of the building is an innovative, locally-manufactured precast concrete panel system with integral insulation that achieves an R-value in excess of building code requirements. The roof is a 'green roof' covered by native plantings, lessening the impact solar heat gain on the building, and reducing air conditioning requirements. The windows are low-E, tinted, and insulated to reduce cooling requirements in summer and heating requirements in winter. The main entrance has an air lock to prevent unconditioned air from entering the building and impacting interior air temperatures. Since much of the traffic in and out of the office building comes from the adjacent Jackson Park Hospital, a pedestrian bridge connects the two buildings, further

  16. Method for controlling a producing zone of a well in a geological formation

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Carl, James R. (Inventor); Byerly, Kent A. (Inventor); Amini, B. Jon (Inventor)

    2005-01-01

    System and methods for transmitting and receiving electromagnetic pulses through a geological formation. A preferably programmable transmitter having an all-digital portion in a preferred embodiment may be operated at frequencies below 1 MHz without loss of target resolution by transmitting and over sampling received long PN codes. A gated and stored portion of the received signal may be correlated with the PN code to determine distances of interfaces within the geological formation, such as the distance of a water interfaces from a wellbore. The received signal is oversampled preferably at rates such as five to fifty times as high as a carrier frequency. In one method of the invention, an oil well with multiple production zones may be kept in production by detecting an approaching water front in one of the production zones and shutting down that particular production zone thereby permitting the remaining production zones to continue operating.

  17. Method for Controlling a Producing Zone of a Well in a Geological Formation

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Carl, James R. (Inventor); Byerly, Kent A. (Inventor); Amini, B. Jon (Inventor)

    2005-01-01

    System and methods for transmitting and receiving electromagnetic pulses through a geological formation. A preferably programmable transmitter having an all-digital portion in a preferred embodiment may be operated at frequencies below 1 MHz without loss of target resolution by transmitting and over sampling received long PN codes. A gated and stored portion of the received signal may be correlated with the PN code to determine distances of interfaces within the geological formation, such as the distance of a water interfaces from a wellbore. The received signal is oversampled preferably at rates such as five to fifty times as high as a carrier frequency. In one method of the invention, an oil well with multiple production zones may be kept in production by detecting an approaching water front in one of the production zones and shutting down that particular production zone thereby permitting the remaining production zones to continue operating.

  18. Energy Building Regulations: The Effect of the Federal Performance Standards on Building Code Administration and the Conservation of Energy in New Buildings.

    ERIC Educational Resources Information Center

    Kopper, William D.

    1980-01-01

    Explores the changes in the administration and enforcement of building regulations that will be engendered by the proposed federal energy building standards. Also evaluates the effectiveness of those standards in meeting congressional intent. Available from U.C. Davis Law Review, School of Law, Martin Luther King Jr. Hall, University of…

  19. Multiblock grid generation with automatic zoning

    NASA Technical Reports Server (NTRS)

    Eiseman, Peter R.

    1995-01-01

    An overview will be given for multiblock grid generation with automatic zoning. We shall explore the many advantages and benefits of this exciting technology and will also see how to apply it to a number of interesting cases. The technology is available in the form of a commercial code, GridPro(registered trademark)/az3000. This code takes surface geometry definitions and patterns of points as its primary input and produces high quality grids as its output. Before we embark upon our exploration, we shall first give a brief background of the environment in which this technology fits.

  20. Evaluation of building fundamental periods and effects of local geology on ground motion parameters in the Siracusa area, Italy

    NASA Astrophysics Data System (ADS)

    Panzera, Francesco; D'Amico, Sebastiano; Lombardo, Giuseppe; Longo, Emanuela

    2016-07-01

    The Siracusa area, located in the southeastern coast of Sicily (Italy), is mainly characterized by the outcropping of a limestone formation. This lithotype, which is overlain by soft sediments such as sandy clays and detritus, can be considered as the local bedrock. Records of ambient noise, processed through spectral ratio techniques, were used to assess the dynamic properties of a sample survey of both reinforced concrete and masonry buildings. The results show that experimental periods of existing buildings are always lower than those proposed by the European seismic code. This disagreement could be related to the role played by stiff masonry infills, as well as the influence of adjacent buildings, especially in downtown Siracusa. Numerical modeling was also used to study the effect of local geology on the seismic site response of the Siracusa area. Seismic urban scenarios were simulated considering a moderate magnitude earthquake (December 13th, 1990) to assess the shaking level of the different outcropping formations. Spectral acceleration at different periods, peak ground acceleration, and velocity were obtained through a stochastic approach adopting an extended source model code. Seismic ground motion scenario highlighted that amplification mainly occurs in the sedimentary deposits that are widespread to the south of the study area as well as on some spot areas where coarse detritus and sandy clay outcrop. On the other hand, the level of shaking appears moderate in all zones with outcropping limestone and volcanics.

  1. Energy consumption quota management of Wanda commercial buildings in China

    NASA Astrophysics Data System (ADS)

    Sun, D. B.; Xiao, H.; Wang, X.; Liu, J. J.; Wang, X.; Jin, X. Q.; Wang, J.; Xie, X. K.

    2016-08-01

    There is limited research of commercial buildings’ energy use data conducted based on practical analysis in China nowadays. Some energy consumption quota tools like Energy Star in U.S or VDI 3807 in Germany have limitation in China's building sector. This study introduces an innovative methodology of applying energy use quota model and empirical management to commercial buildings, which was in accordance of more than one hundred opened shopping centers of a real estate group in China. On the basis of statistical benchmarking, a new concept of “Modified coefficient”, which considers weather, occupancy, business layout, operation schedule and HVAC efficiency, is originally introduced in this paper. Our study shows that the average energy use quota increases from north to south. The average energy use quota of sample buildings is 159 kWh/(m2.a) of severe cold climate zone, 179 kWh/(m2.a) of cold zone, 188 kWh/(m2.a) of hot summer and cold winter zone, and 200 kWh/(m2.a) of hot summer and warm winter zone. The energy use quota model has been validated in the property management for year 2016, providing a new method of commercial building energy management to the industry. As a key result, there is 180 million energy saving potential based on energy quota management in 2016, equals to 6.2% saving rate of actual energy use in 2015.

  2. Responses of a tall building with U.S. code-type instrumentation in Tokyo, Japan, to events before, during and after the Tohoku earthquake of 11 March 2011

    USGS Publications Warehouse

    Çelebi, Mehmet; Kashima, Toshihide; Ghahari, S. Farid; Abazarsa, Fariba; Taciroglu, Ertugrul

    2016-01-01

    The 11 March 2011 M 9.0 Tohoku earthquake generated long-duration shaking that propagated hundreds of kilometers from the epicenter and affected tall buildings in urban areas several hundred kilometers from the epicenter of the main shock. Recorded responses show that tall buildings were affected by long-period motions. This study presents the behavior and performance of a 37-story building in the Tsukuda area of Tokyo, Japan, as inferred from modal analyses of records retrieved for a time interval covering a few days before, during, and for several months after the main shock. The U.S. “code-type” array comprises three triaxial accelerometers deployed at three levels in the superstructure. Such a sparse array in a tall structure limits a reliable assessment, because its performance must be based on only the average drift ratios. Based on the inferred values of this parameter, the subject building was not structurally damaged.

  3. Energy efficiency evaluation of hospital building office

    NASA Astrophysics Data System (ADS)

    Fitriani, Indah; Sangadji, Senot; Kristiawan, S. A.

    2017-01-01

    One of the strategy employed in building design is reducing energy consumption while maintaining the best comfort zone in building indoor climate. The first step to improve office buildings energy performance by evaluating its existing energy usage using energy consumption intensity (Intensitas Konsumsi Energi, IKE) index. Energy evaluation of office building for hospital dr. Sayidiman at Kabupaten Magetan has been carried out in the initial investigation. The office building is operated with active cooling (air conditioning, AC) and use limited daylighting which consumes 14.61 kWh/m2/month. This IKE value is attributed into a slightly inefficient category. Further investigation was carried out by modeling and simulating thermal energy load and room lighting in every building zone using of Ecotect from Autodesk. Three scenarios of building energy and lighting retrofit have been performed simulating representing energy efficiency using cross ventilation, room openings, and passive cooling. The results of the numerical simulation indicate that the third scenario by employing additional windows, reflector media and skylight exhibit the best result and in accordance with SNI 03-6575-2001 lighting standard. Total thermal load of the existing building which includes fabric gains, indirect solar gains, direct solar gains, ventilation fans, internal gains, inter-zonal gains and cooling load were 162,145.40 kWh. Based on the three scenarios, the thermal load value (kWh) obtained was lowest achieved scenario 2 with the thermal value of 117,539.08 kWh.The final results are interpreted from the total energy emissions evaluated using the Ecotect software, the heating and cooling demand value and specific design of the windows are important factors to determine the energy efficiency of the buildings.

  4. Building a Better Trojan Horse: Emerging Army Roles in Joint Urban Operations

    DTIC Science & Technology

    2001-01-01

    Building a Better Trojan Horse : Emerging Army Roles in Joint Urban Operations A Monograph by MAJ Christopher H. Beckert Infantry, U.S. Army School...xx-xx-2000 to xx-xx-2000 5a. CONTRACT NUMBER 5b. GRANT NUMBER 4. TITLE AND SUBTITLE Building a Better Trojan Horse : Emerging Army Roles in Joint...TELEPHONE NUMBER International Area Code Area Code Telephone Number 703 767-9007 DSN 427-9007 2 Abstract BUILDING A BETTER TROJAN HORSE : EMERGING ARMY

  5. A publicly available SSC+EC code.

    NASA Astrophysics Data System (ADS)

    Georganopoulos, M.; Perlman, E. S.; Kazanas, D.; Wingert, B.; Castro, R.

    2004-08-01

    We present a time-dependent one zone SSC+EC code that takes into account the KN-cross section, and calculates self-consistently all orders of Compton scattering. In particular, it produces separate results for the first order Compton component, and for the total Compton emission. The kinetic equation is solved using a stable implicit scheme, and the user can select from a range of physically motivated temporal electron injection profile. The code is written in C, is fully documented and will soon be publicly available through the Internet, along with a set of IDL visualization routines.

  6. A methodology for delineating planning-level channel migration zones.

    DOT National Transportation Integrated Search

    2014-07-01

    The Washington State administrative codes that implement the Shoreline Management Act (SMA) require communities to identify the general location of channel migration zones (CMZs), and regulate development within these areas on shoreline streams. Shor...

  7. Assessing Urban Streets Network Vulnerability against Earthquake Using GIS - Case Study: 6TH Zone of Tehran

    NASA Astrophysics Data System (ADS)

    Rastegar, A.

    2017-09-01

    Great earthquakes cause huge damages to human life. Street networks vulnerability makes the rescue operation to encounter serious difficulties especially at the first 72 hours after the incident. Today, physical expansion and high density of great cities, due to narrow access roads, large distance from medical care centers and location at areas with high seismic risk, will lead to a perilous and unpredictable situation in case of the earthquake. Zone # 6 of Tehran, with 229,980 population (3.6% of city population) and 20 km2 area (3.2% of city area), is one of the main municipal zones of Tehran (Iran center of statistics, 2006). Major land-uses, like ministries, embassies, universities, general hospitals and medical centers, big financial firms and so on, manifest the high importance of this region on local and national scale. In this paper, by employing indexes such as access to medical centers, street inclusion, building and population density, land-use, PGA and building quality, vulnerability degree of street networks in zone #6 against the earthquake is calculated through overlaying maps and data in combination with IHWP method and GIS. This article concludes that buildings alongside the streets with high population and building density, low building quality, far to rescue centers and high level of inclusion represent high rate of vulnerability, compared with other buildings. Also, by moving on from north to south of the zone, the vulnerability increases. Likewise, highways and streets with substantial width and low building and population density hold little values of vulnerability.

  8. Reproducible research in vadose zone sciences

    USDA-ARS?s Scientific Manuscript database

    A significant portion of present-day soil and Earth science research is computational, involving complex data analysis pipelines, advanced mathematical and statistical models, and sophisticated computer codes. Opportunities for scientific progress are greatly diminished if reproducing and building o...

  9. Towards Realistic Implementations of a Majorana Surface Code.

    PubMed

    Landau, L A; Plugge, S; Sela, E; Altland, A; Albrecht, S M; Egger, R

    2016-02-05

    Surface codes have emerged as promising candidates for quantum information processing. Building on the previous idea to realize the physical qubits of such systems in terms of Majorana bound states supported by topological semiconductor nanowires, we show that the basic code operations, namely projective stabilizer measurements and qubit manipulations, can be implemented by conventional tunnel conductance probes and charge pumping via single-electron transistors, respectively. The simplicity of the access scheme suggests that a functional code might be in close experimental reach.

  10. Do Performance-Based Codes Support Universal Design in Architecture?

    PubMed

    Grangaard, Sidse; Frandsen, Anne Kathrine

    2016-01-01

    The research project 'An analysis of the accessibility requirements' studies how Danish architectural firms experience the accessibility requirements of the Danish Building Regulations and it examines their opinions on how future regulative models can support innovative and inclusive design - Universal Design (UD). The empirical material consists of input from six workshops to which all 700 Danish Architectural firms were invited, as well as eight group interviews. The analysis shows that the current prescriptive requirements are criticized for being too homogenous and possibilities for differentiation and zoning are required. Therefore, a majority of professionals are interested in a performance-based model because they think that such a model will support 'accessibility zoning', achieving flexibility because of different levels of accessibility in a building due to its performance. The common understanding of accessibility and UD is directly related to buildings like hospitals and care centers. When the objective is both innovative and inclusive architecture, the request of a performance-based model should be followed up by a knowledge enhancement effort in the building sector. Bloom's taxonomy of educational objectives is suggested as a tool for such a boost. The research project has been financed by the Danish Transport and Construction Agency.

  11. Energy analysis of cool, medium, and dark roofs on residential buildings in the U.S

    NASA Astrophysics Data System (ADS)

    Dunbar, Michael A.

    This study reports an energy analysis of cool, medium, and dark roofs on residential buildings in the U.S. Three analyses were undertaken in this study: energy consumption, economic analysis, and an environmental analysis. The energy consumption reports the electricity and natural gas consumption of the simulations. The economic analysis uses tools such as simple payback period (SPP) and net present value (NPV) to determine the profitability of the cool roof and the medium roof. The variable change for each simulation model was the roof color. The default color was a dark roof and the results were focused on the changes produced by the cool roof and the medium roof. The environmental analysis uses CO2 emissions to assess the environmental impact of the cool roof and the medium roof. The analysis uses the U.S. Department of Energy (DOE) EnergyPlus software to produce simulations of a typical, two-story residential home in the U.S. The building details of the typical, two-story U.S. residential home and the International Energy Conservation Code (IECC) building code standards used are discussed in this study. This study indicates that, when material and labor costs are. assessed, the cool roof and the medium roof do not yield a SPP less than 10 years. Furthermore, the NPV results assess that neither the cool roof nor the medium roof are a profitable investment in any climate zone in the U.S. The environmental analysis demonstrates that both the cool roof and the medium roof have a positive impact in warmer climates by reducing the CO2 emissions as much as 264 kg and 129 kg, respectively.

  12. Smart building temperature control using occupant feedback

    NASA Astrophysics Data System (ADS)

    Gupta, Santosh K.

    This work was motivated by the problem of computing optimal commonly-agreeable thermal settings in spaces with multiple occupants. In this work we propose algorithms that take into account each occupant's preferences along with the thermal correlations between different zones in a building, to arrive at optimal thermal settings for all zones of the building in a coordinated manner. In the first part of this work we incorporate active occupant feedback to minimize aggregate user discomfort and total energy cost. User feedback is used to estimate the users comfort range, taking into account possible inaccuracies in the feedback. The control algorithm takes the energy cost into account, trading it off optimally with the aggregate user discomfort. A lumped heat transfer model based on thermal resistance and capacitance is used to model a multi-zone building. We provide a stability analysis and establish convergence of the proposed solution to a desired temperature that minimizes the sum of energy cost and aggregate user discomfort. However, for convergence to the optimal, sufficient separation between the user feedback frequency and the dynamics of the system is necessary; otherwise, the user feedback provided do not correctly reflect the effect of current control input value on user discomfort. The algorithm is further extended using singular perturbation theory to determine the minimum time between successive user feedback solicitations. Under sufficient time scale separation, we establish convergence of the proposed solution. Simulation study and experimental runs on the Watervliet based test facility demonstrates performance of the algorithm. In the second part we develop a consensus algorithm for attaining a common temperature set-point that is agreeable to all occupants of a zone in a typical multi-occupant space. The information on the comfort range functions is indeed held privately by each occupant. Using occupant differentiated dynamically adjusted prices as

  13. 45 CFR 12.3 - General policies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... with State or local zoning restrictions, building codes, or similar limitations. (e) Organizations...-exempt under section 501(c)(3) of the Internal Revenue Code of 1954. (c) Real property will be requested...

  14. 45 CFR 12.3 - General policies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... with State or local zoning restrictions, building codes, or similar limitations. (e) Organizations...-exempt under section 501(c)(3) of the Internal Revenue Code of 1954. (c) Real property will be requested...

  15. 45 CFR 12.3 - General policies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... with State or local zoning restrictions, building codes, or similar limitations. (e) Organizations...-exempt under section 501(c)(3) of the Internal Revenue Code of 1954. (c) Real property will be requested...

  16. 45 CFR 12.3 - General policies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... with State or local zoning restrictions, building codes, or similar limitations. (e) Organizations...-exempt under section 501(c)(3) of the Internal Revenue Code of 1954. (c) Real property will be requested...

  17. Xenomicrobiology: a roadmap for genetic code engineering.

    PubMed

    Acevedo-Rocha, Carlos G; Budisa, Nediljko

    2016-09-01

    Biology is an analytical and informational science that is becoming increasingly dependent on chemical synthesis. One example is the high-throughput and low-cost synthesis of DNA, which is a foundation for the research field of synthetic biology (SB). The aim of SB is to provide biotechnological solutions to health, energy and environmental issues as well as unsustainable manufacturing processes in the frame of naturally existing chemical building blocks. Xenobiology (XB) goes a step further by implementing non-natural building blocks in living cells. In this context, genetic code engineering respectively enables the re-design of genes/genomes and proteins/proteomes with non-canonical nucleic (XNAs) and amino (ncAAs) acids. Besides studying information flow and evolutionary innovation in living systems, XB allows the development of new-to-nature therapeutic proteins/peptides, new biocatalysts for potential applications in synthetic organic chemistry and biocontainment strategies for enhanced biosafety. In this perspective, we provide a brief history and evolution of the genetic code in the context of XB. We then discuss the latest efforts and challenges ahead for engineering the genetic code with focus on substitutions and additions of ncAAs as well as standard amino acid reductions. Finally, we present a roadmap for the directed evolution of artificial microbes for emancipating rare sense codons that could be used to introduce novel building blocks. The development of such xenomicroorganisms endowed with a 'genetic firewall' will also allow to study and understand the relation between code evolution and horizontal gene transfer. © 2016 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  18. Proceduracy: Computer Code Writing in the Continuum of Literacy

    ERIC Educational Resources Information Center

    Vee, Annette

    2010-01-01

    This dissertation looks at computer programming through the lens of literacy studies, building from the concept of code as a written text with expressive and rhetorical power. I focus on the intersecting technological and social factors of computer code writing as a literacy--a practice I call "proceduracy". Like literacy, proceduracy is a human…

  19. Thermal dynamic simulation of wall for building energy efficiency under varied climate environment

    NASA Astrophysics Data System (ADS)

    Wang, Xuejin; Zhang, Yujin; Hong, Jing

    2017-08-01

    Aiming at different kind of walls in five cities of different zoning for thermal design, using thermal instantaneous response factors method, the author develops software to calculation air conditioning cooling load temperature, thermal response factors, and periodic response factors. On the basis of the data, the author gives the net work analysis about the influence of dynamic thermal of wall on air-conditioning load and thermal environment in building of different zoning for thermal design regional, and put forward the strategy how to design thermal insulation and heat preservation wall base on dynamic thermal characteristic of wall under different zoning for thermal design regional. And then provide the theory basis and the technical references for the further study on the heat preservation with the insulation are in the service of energy saving wall design. All-year thermal dynamic load simulating and energy consumption analysis for new energy-saving building is very important in building environment. This software will provide the referable scientific foundation for all-year new thermal dynamic load simulation, energy consumption analysis, building environment systems control, carrying through farther research on thermal particularity and general particularity evaluation for new energy -saving walls building. Based on which, we will not only expediently design system of building energy, but also analyze building energy consumption and carry through scientific energy management. The study will provide the referable scientific foundation for carrying through farther research on thermal particularity and general particularity evaluation for new energy saving walls building.

  20. Digitizing zone maps, using modified LARSYS program. [computer graphics and computer techniques for mapping

    NASA Technical Reports Server (NTRS)

    Giddings, L.; Boston, S.

    1976-01-01

    A method for digitizing zone maps is presented, starting with colored images and producing a final one-channel digitized tape. This method automates the work previously done interactively on the Image-100 and Data Analysis System computers of the Johnson Space Center (JSC) Earth Observations Division (EOD). A color-coded map was digitized through color filters on a scanner to form a digital tape in LARSYS-2 or JSC Universal format. The taped image was classified by the EOD LARSYS program on the basis of training fields included in the image. Numerical values were assigned to all pixels in a given class, and the resulting coded zone map was written on a LARSYS or Universal tape. A unique spatial filter option permitted zones to be made homogeneous and edges of zones to be abrupt transitions from one zone to the next. A zoom option allowed the output image to have arbitrary dimensions in terms of number of lines and number of samples on a line. Printouts of the computer program are given and the images that were digitized are shown.

  1. Achieving 50% Energy Savings in Office Buildings, Advanced Energy Design Guides: Office Buildings (Brochure)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-09-01

    This fact sheet summarizes recommendations for designing new office buildings that result in 50% less energy use than conventional designs meeting minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for Small to Medium Office Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use office buildings with gross floor areas up to 100,000 ft2 (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller office buildings with insufficient budgets to fully implement best practices for integrated design and optimized performance. Themore » recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of office buildings.« less

  2. 2013 Building Technologies Office Program Peer Review Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2013-11-01

    The 2013 Building Technologies Office Program Peer Review Report summarizes the results of the 2013 Building Technologies Office (BTO) peer review, which was held in Washington, D.C., on April 2–4, 2013. The review was attended by over 300 participants and included presentations on 59 BTO-funded projects: 29 from BTO’s Emerging Technologies Program, 20 from the Commercial Buildings Integration Program, 6 from the Residential Buildings Integration Program, and 4 from the Building Energy Codes Program. This report summarizes the scores and comments provided by the independent reviewers for each project.

  3. Construction and design defects in the residential buildings and observed earthquake damage types in Turkey

    NASA Astrophysics Data System (ADS)

    Cogurcu, M. T.

    2015-04-01

    Turkey is situated in a very active earthquake region. In the last century, several earthquakes resulted in thousands of deaths and enormous economic losses. In 1999, the Kocaeli earthquake had an approximate death toll of more than 20 000, and in 2011 the Van earthquake killed 604 people. In general, Turkish residential buildings have reinforced concrete structural systems. These reinforced concrete structures have several deficiencies, such as low concrete quality, non-seismic steel detailing and inappropriate structural systems including several architectural irregularities. In this study, the general characteristics of Turkish building stock and the deficiencies observed in structural systems are explained, and illustrative figures are given with reference to the Turkish Earthquake Code 2007. The poor concrete quality, lack of lateral or transverse reinforcement in beam-column joints and column confinement zones, high stirrup spacings, under-reinforced columns and over-reinforced beams are the primary causes of failures. Other deficiencies include weak-column-stronger-beam formations, insufficient seismic joint separations, soft-story or weak-story irregularities and short columns. Similar construction and design mistakes are also observed in other countries situated on active earthquake belts. Existing buildings still have these undesirable characteristics, and so to prepare for future earthquakes they must be rehabilitated.

  4. Determination of the pore fluid pressure ratio at seismogenic megathrusts in subduction zones: Implications for strength of asperities and Andean-type mountain building

    NASA Astrophysics Data System (ADS)

    Seno, Tetsuzo

    2009-05-01

    We construct the differential stress profile across the fore arc in a subduction zone from the force balance between the shear stress, τ, at seismogenic megathrust and the lithostatic pressure. We assume that τ is written by μ (1 - λ) σn, where λ is the pore fluid pressure ratio, μ is the coefficient of static friction, and σn is the normal stress. Given a density structure of the fore-arc wedge, we determine λ by comparing calculated fore-arc stresses with observed ones, as 0.95-0.98 in Shikoku, Miyagi, Peru, north Chile, and south Chile and 0.90-0.93 in south Vancouver Island and Washington. The parameter τ averaged over the seismogenic megathrust is of the order of ˜10 MPa. Stress drops of great earthquakes in these zones occupy 14-87% and not a constant fraction of τ. They, on the other hand, increase linearly with 1 - λ. We propose a simple fault model in which the area of asperities as a fraction of the total fault area is proportional to 1 - λ. Variation of fractional area of asperities thus may explain the observed correlation and the regional variation of λ. Assuming that the differential stress at summit of the Andean mountains is zero, not at the coast as observed at present, we determine λ to be 0.84 in north Chile in the mountain building stage. Such a smaller value of λ, along with λ < ˜0.4 in collision zones previously obtained and >˜0.9 in subduction zones, would suggest that variation of λ controls the tectonic style of the Earth.

  5. Comparison of PSF maxima and minima of multiple annuli coded aperture (MACA) and complementary multiple annuli coded aperture (CMACA) systems

    NASA Astrophysics Data System (ADS)

    Ratnam, Challa; Lakshmana Rao, Vadlamudi; Lachaa Goud, Sivagouni

    2006-10-01

    In the present paper, and a series of papers to follow, the Fourier analytical properties of multiple annuli coded aperture (MACA) and complementary multiple annuli coded aperture (CMACA) systems are investigated. First, the transmission function for MACA and CMACA is derived using Fourier methods and, based on the Fresnel-Kirchoff diffraction theory, the formulae for the point spread function are formulated. The PSF maxima and minima are calculated for both the MACA and CMACA systems. The dependence of these properties on the number of zones is studied and reported in this paper.

  6. Demonstration of reduced-order urban scale building energy models

    DOE PAGES

    Heidarinejad, Mohammad; Mattise, Nicholas; Dahlhausen, Matthew; ...

    2017-09-08

    The aim of this study is to demonstrate a developed framework to rapidly create urban scale reduced-order building energy models using a systematic summary of the simplifications required for the representation of building exterior and thermal zones. These urban scale reduced-order models rely on the contribution of influential variables to the internal, external, and system thermal loads. OpenStudio Application Programming Interface (API) serves as a tool to automate the process of model creation and demonstrate the developed framework. The results of this study show that the accuracy of the developed reduced-order building energy models varies only up to 10% withmore » the selection of different thermal zones. In addition, to assess complexity of the developed reduced-order building energy models, this study develops a novel framework to quantify complexity of the building energy models. Consequently, this study empowers the building energy modelers to quantify their building energy model systematically in order to report the model complexity alongside the building energy model accuracy. An exhaustive analysis on four university campuses suggests that the urban neighborhood buildings lend themselves to simplified typical shapes. Specifically, building energy modelers can utilize the developed typical shapes to represent more than 80% of the U.S. buildings documented in the CBECS database. One main benefits of this developed framework is the opportunity for different models including airflow and solar radiation models to share the same exterior representation, allowing a unifying exchange data. Altogether, the results of this study have implications for a large-scale modeling of buildings in support of urban energy consumption analyses or assessment of a large number of alternative solutions in support of retrofit decision-making in the building industry.« less

  7. Demonstration of reduced-order urban scale building energy models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heidarinejad, Mohammad; Mattise, Nicholas; Dahlhausen, Matthew

    The aim of this study is to demonstrate a developed framework to rapidly create urban scale reduced-order building energy models using a systematic summary of the simplifications required for the representation of building exterior and thermal zones. These urban scale reduced-order models rely on the contribution of influential variables to the internal, external, and system thermal loads. OpenStudio Application Programming Interface (API) serves as a tool to automate the process of model creation and demonstrate the developed framework. The results of this study show that the accuracy of the developed reduced-order building energy models varies only up to 10% withmore » the selection of different thermal zones. In addition, to assess complexity of the developed reduced-order building energy models, this study develops a novel framework to quantify complexity of the building energy models. Consequently, this study empowers the building energy modelers to quantify their building energy model systematically in order to report the model complexity alongside the building energy model accuracy. An exhaustive analysis on four university campuses suggests that the urban neighborhood buildings lend themselves to simplified typical shapes. Specifically, building energy modelers can utilize the developed typical shapes to represent more than 80% of the U.S. buildings documented in the CBECS database. One main benefits of this developed framework is the opportunity for different models including airflow and solar radiation models to share the same exterior representation, allowing a unifying exchange data. Altogether, the results of this study have implications for a large-scale modeling of buildings in support of urban energy consumption analyses or assessment of a large number of alternative solutions in support of retrofit decision-making in the building industry.« less

  8. Utility of de-escalatory confidence-building measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nation, J.

    1989-06-01

    This paper evaluates the utility of specific confidence-building de-escalatory measures and pays special attention to the evaluation of measures which place restrictions on or establish procedures for strategic forces. Some measures appear more promising than others. Potentially useful confidence-building measures largely satisfy defined criteria and include the phased return of strategic nuclear forces to peacetime bases and operations, the termination of interference with communications and NTMs (National Technical Means) and the termination of civil defense preparations. Less-promising CBMs include the standing down of supplemental early warning systems, the establishment of SSBN keep-out zones, and decreases in bomber alert rates. Establishmentmore » of SSBN keep-out zones and reduction in bomber rates are difficult to verify, while the standing-down of early warning systems provides little benefit at potentially large costs. Particular confidence-building measures (CBMs) may be most useful in building superpower confidence at specific points in the crisis termination phase. For example, a decrease in strategic bomber alert rates may provide some decrease in perception of the likelihood of war, but its potential costs, particularly in increasing bomber vulnerability, may limit its utility and implementation to the final crisis stages when the risks of re-escalation and surprise attack are lower.« less

  9. Evaluation of liquefaction potential for building code

    NASA Astrophysics Data System (ADS)

    Nunziata, C.; De Nisco, G.; Panza, G. F.

    2008-07-01

    The standard approach for the evaluation of the liquefaction susceptibility is based on the estimation of a safety factor between the cyclic shear resistance to liquefaction and the earthquake induced shear stress. Recently, an updated procedure based on shear-wave velocities (Vs) has been proposed which could be more easily applied. These methods have been applied at La Plaja beach of Catania, that experienced liquefaction because of the 1693 earthquake. The detailed geotechnical and Vs information and the realistic ground motion computed for the 1693 event let us compare the two approaches. The successful application of the Vs procedure, slightly modified to fit historical and safety factor information, even if additional field performances are needed, encourages the development of a guide for liquefaction potential analysis, based on well defined Vs profiles to be included in the italian seismic code.

  10. 75 FR 33696 - Safety Zone: July Firework Display in Captain of the Port, Puget Sound AOR

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-15

    ...-AA00 Safety Zone: July Firework Display in Captain of the Port, Puget Sound AOR AGENCY: Coast Guard... Captain of the Port, Puget Sound AOR. (a) Safety Zone. The following area is a designated safety zone: all..., Captain of the Port, Puget Sound. [FR Doc. 2010-14294 Filed 6-14-10; 8:45 am] BILLING CODE 9110-04-P ...

  11. "AfterZone:" Outcomes for Youth Participating in Providence's Citywide After-School System

    ERIC Educational Resources Information Center

    Kauh, Tina J.

    2011-01-01

    This report presents findings from a two-year quasi-experimental evaluation of the "AfterZone"--a citywide system-building effort in Providence, Rhode Island, that aims to provide high-quality, accessible out-of-school-time services to middle school youth. The AfterZone model is unique in that it is built on a network of…

  12. Vadose Zone Transport Field Study: Status Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gee, Glendon W.; Ward, Anderson L.

    2001-11-30

    Studies were initiated at the Hanford Site to evaluate the process controlling the transport of fluids in the vadose zone and to develop a reliable database upon which vadose-zone transport models can be calibrated. These models are needed to evaluate contaminant migration through the vadose zone to underlying groundwaters at Hanford. A study site that had previously been extensively characterized using geophysical monitoring techniques was selected in the 200 E Area. Techniques used previously included neutron probe for water content, spectral gamma logging for radionuclide tracers, and gamma scattering for wet bulk density. Building on the characterization efforts of themore » past 20 years, the site was instrumented to facilitate the comparison of nine vadose-zone characterization methods: advanced tensiometers, neutron probe, electrical resistance tomography (ERT), high-resolution resistivity (HRR), electromagnetic induction imaging (EMI), cross-borehole radar (XBR), and cross-borehole seismic (XBS). Soil coring was used to obtain soil samples for analyzing ionic and isotopic tracers.« less

  13. Mock Code: A Code Blue Scenario Requested by and Developed for Registered Nurses

    PubMed Central

    Rideout, Janice; Pritchett-Kelly, Sherry; McDonald, Melissa; Mullins-Richards, Paula; Dubrowski, Adam

    2016-01-01

    The use of simulation in medical training is quickly becoming more common, with applications in emergency, surgical, and nursing education. Recently, registered nurses working in surgical inpatient units requested a mock code simulation to practice skills, improve knowledge, and build self-confidence in a safe and controlled environment. A simulation scenario using a high-fidelity mannequin was developed and will be discussed herein. PMID:28123919

  14. Compliance Verification Paths for Residential and Commercial Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, David R.; Makela, Eric J.; Fannin, Jerica D.

    2011-10-10

    This report looks at different ways to verify energy code compliance and to ensure that the energy efficiency goals of an adopted document are achieved. Conformity assessment is the body of work that ensures compliance, including activities that can ensure residential and commercial buildings satisfy energy codes and standards. This report identifies and discusses conformity-assessment activities and provides guidance for conducting assessments.

  15. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Arkansas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Arkansas. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Arkansas.

  16. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Texas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Texas. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Texas.

  17. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Minnesota. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Minnesota.

  18. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Indiana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Indiana. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Indiana.

  19. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Oklahoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Oklahoma. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Oklahoma.

  20. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Massachusetts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Massachusetts. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Massachusetts.

  1. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Florida. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Florida.

  2. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Maine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Maine. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Maine.

  3. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Vermont

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Vermont. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Vermont.

  4. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Louisiana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Louisiana. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Louisiana.

  5. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Alabama

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Alabama. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Alabama.

  6. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Colorado. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Colorado.

  7. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Michigan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Michigan. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Michigan.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Arizona. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Arizona.

  9. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Maryland. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Maryland.

  10. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Wisconsin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Wisconsin. Moving to the 2015 IECC from the 2006 IECC base code is cost-effective for residential buildings in all climate zones in Wisconsin.

  11. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Ohio. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Ohio.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Connecticut. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Connecticut.

  13. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Illinois

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Illinois. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Illinois.

  14. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Pennsylvania. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Pennsylvania.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Hawaii. Moving to the 2015 IECC from the 2006 IECC base code is cost-effective for residential buildings in all climate zones in Hawaii.

  16. Architectural layout and vulnerability to earthquakes of housing buildings of the Modernism

    NASA Astrophysics Data System (ADS)

    Bostenaru, M.

    2009-04-01

    seismic culture developed. The buildings of Greek Modernism and those of the Milanese Novecento however, are more regular in shape and in the distribution of columns and beams. It will be investigated if this is a consequence of the local seismic culture or if it was simply allowed by the regular shape of the lots in the urban tissue. Buildings of Greek Modernism were raised, unlike those in Bucharest, in more peripheral zones of the city, mainly in the neighbourship of the train station. In Bucharest they were raised in the city centre, following a major urban redevelopment. The buildings of Milanese Novecento, however, are spread over the whole city and here it is more difficult to find a reason in the argumentative discourse. It will be looked at the vernacular types of the houses in the country. The Modernist buildings were raised in a time when no seismic codes yet were released. All of the mentioned building types have a reinforced concrete skeleton. When conducting studies about historical buildings, mainly those with masonry structure are considered, for which reason the project CA'REDIVIVUS was run 2005-2007, with support from the European Commission, aiming exactly at this: the preservation of historic housing buildings with reinforced concrete structure across Europe. This research aims to continue that research, considering buildings from the same geographical locations but from the point of view of the way of living which led to the architectural shape which rendered vulnerable or not these buildings. It is an argumentative discourse to be conducted about to which amount the Modernism negated the historical links and thus also the vernacular one. Sure is, that at least on Romania, there had to be a change in living habits to move from single family to multi-family building. These buildings were also not typical for Modernism in Europe, since they were thought for luxus dwellings in the city centre. In Western Europe it was social housing at the periphery

  17. Ethical Guidelines for Structural Interventions to Small-Scale Historic Stone Masonry Buildings.

    PubMed

    Hurol, Yonca; Yüceer, Hülya; Başarır, Hacer

    2015-12-01

    Structural interventions to historic stone masonry buildings require that both structural and heritage values be considered simultaneously. The absence of one of these value systems in implementation can be regarded as an unethical professional action. The research objective of this article is to prepare a guideline for ensuring ethical structural interventions to small-scale stone historic masonry buildings in the conservation areas of Northern Cyprus. The methodology covers an analysis of internationally accepted conservation documents and national laws related to the conservation of historic buildings, an analysis of building codes, especially Turkish building codes, which have been used in Northern Cyprus, and an analysis of the structural interventions introduced to a significant historic building in a semi-intact state in the walled city of Famagusta. This guideline covers issues related to whether buildings are intact or ruined, the presence of earthquake risk, the types of structural decisions in an architectural conservation project, and the values to consider during the decision making phase.

  18. A combinatorial code for pattern formation in Drosophila oogenesis.

    PubMed

    Yakoby, Nir; Bristow, Christopher A; Gong, Danielle; Schafer, Xenia; Lembong, Jessica; Zartman, Jeremiah J; Halfon, Marc S; Schüpbach, Trudi; Shvartsman, Stanislav Y

    2008-11-01

    Two-dimensional patterning of the follicular epithelium in Drosophila oogenesis is required for the formation of three-dimensional eggshell structures. Our analysis of a large number of published gene expression patterns in the follicle cells suggests that they follow a simple combinatorial code based on six spatial building blocks and the operations of union, difference, intersection, and addition. The building blocks are related to the distribution of inductive signals, provided by the highly conserved epidermal growth factor receptor and bone morphogenetic protein signaling pathways. We demonstrate the validity of the code by testing it against a set of patterns obtained in a large-scale transcriptional profiling experiment. Using the proposed code, we distinguish 36 distinct patterns for 81 genes expressed in the follicular epithelium and characterize their joint dynamics over four stages of oogenesis. The proposed combinatorial framework allows systematic analysis of the diversity and dynamics of two-dimensional transcriptional patterns and guides future studies of gene regulation.

  19. Building an ontology of pulmonary diseases with natural language processing tools using textual corpora.

    PubMed

    Baneyx, Audrey; Charlet, Jean; Jaulent, Marie-Christine

    2007-01-01

    Pathologies and acts are classified in thesauri to help physicians to code their activity. In practice, the use of thesauri is not sufficient to reduce variability in coding and thesauri are not suitable for computer processing. We think the automation of the coding task requires a conceptual modeling of medical items: an ontology. Our task is to help lung specialists code acts and diagnoses with software that represents medical knowledge of this concerned specialty by an ontology. The objective of the reported work was to build an ontology of pulmonary diseases dedicated to the coding process. To carry out this objective, we develop a precise methodological process for the knowledge engineer in order to build various types of medical ontologies. This process is based on the need to express precisely in natural language the meaning of each concept using differential semantics principles. A differential ontology is a hierarchy of concepts and relationships organized according to their similarities and differences. Our main research hypothesis is to apply natural language processing tools to corpora to develop the resources needed to build the ontology. We consider two corpora, one composed of patient discharge summaries and the other being a teaching book. We propose to combine two approaches to enrich the ontology building: (i) a method which consists of building terminological resources through distributional analysis and (ii) a method based on the observation of corpus sequences in order to reveal semantic relationships. Our ontology currently includes 1550 concepts and the software implementing the coding process is still under development. Results show that the proposed approach is operational and indicates that the combination of these methods and the comparison of the resulting terminological structures give interesting clues to a knowledge engineer for the building of an ontology.

  20. Identification of the inflow zone of unruptured cerebral aneurysms: comparison of 4D flow MRI and 3D TOF MRA data.

    PubMed

    Futami, K; Sano, H; Misaki, K; Nakada, M; Ueda, F; Hamada, J

    2014-07-01

    The hemodynamics of the inflow zone of cerebral aneurysms may be a key factor in coil compaction and recanalization after endovascular coil embolization. We performed 4D flow MR imaging in conjunction with 3D TOF MRA and compared their ability to identify the inflow zone of unruptured cerebral aneurysms. This series comprised 50 unruptured saccular cerebral aneurysms in 44 patients. Transluminal color-coded 3D MRA images were created by selecting the signal-intensity ranges on 3D TOF MRA images that corresponded with both the luminal margin and the putative inflow. 4D flow MR imaging demonstrated the inflow zone and yielded inflow velocity profiles for all 50 aneurysms. In 18 of 24 lateral-projection aneurysms (75%), the inflow zone was located distally on the aneurysmal neck. The maximum inflow velocity ranged from 285 to 922 mm/s. On 4D flow MR imaging and transluminal color-coded 3D MRA studies, the inflow zone of 32 aneurysms (64%) was at a similar location. In 91% of aneurysms whose neck section plane angle was <30° with respect to the imaging section direction on 3D TOF MRA, depiction of the inflow zone was similar on transluminal color-coded 3D MRA and 4D flow MR images. 4D flow MR imaging can demonstrate the inflow zone and provide inflow velocity profiles. In aneurysms whose angle of the neck-section plane is obtuse vis-a-vis the imaging section on 3D TOF MRA scans, transluminal color-coded 3D MRA may depict the inflow zone reliably. © 2014 by American Journal of Neuroradiology.

  1. Manual for obscuration code with space station applications

    NASA Technical Reports Server (NTRS)

    Marhefka, R. J.; Takacs, L.

    1986-01-01

    The Obscuration Code, referred to as SHADOW, is a user-oriented computer code to determine the case shadow of an antenna in a complex environment onto the far zone sphere. The surrounding structure can be composed of multiple composite cone frustums and multiply sided flat plates. These structural pieces are ideal for modeling space station configurations. The means of describing the geometry input is compatible with the NEC-BASIC Scattering Code. In addition, an interactive mode of operation has been provided for DEC VAX computers. The first part of this document is a user's manual designed to give a description of the method used to obtain the shadow map, to provide an overall view of the operation of the computer code, to instruct a user in how to model structures, and to give examples of inputs and outputs. The second part is a code manual that details how to set up the interactive and non-interactive modes of the code and provides a listing and brief description of each of the subroutines.

  2. Rate-distortion analysis of dead-zone plus uniform threshold scalar quantization and its application--part II: two-pass VBR coding for H.264/AVC.

    PubMed

    Sun, Jun; Duan, Yizhou; Li, Jiangtao; Liu, Jiaying; Guo, Zongming

    2013-01-01

    In the first part of this paper, we derive a source model describing the relationship between the rate, distortion, and quantization steps of the dead-zone plus uniform threshold scalar quantizers with nearly uniform reconstruction quantizers for generalized Gaussian distribution. This source model consists of rate-quantization, distortion-quantization (D-Q), and distortion-rate (D-R) models. In this part, we first rigorously confirm the accuracy of the proposed source model by comparing the calculated results with the coding data of JM 16.0. Efficient parameter estimation strategies are then developed to better employ this source model in our two-pass rate control method for H.264 variable bit rate coding. Based on our D-Q and D-R models, the proposed method is of high stability, low complexity and is easy to implement. Extensive experiments demonstrate that the proposed method achieves: 1) average peak signal-to-noise ratio variance of only 0.0658 dB, compared to 1.8758 dB of JM 16.0's method, with an average rate control error of 1.95% and 2) significant improvement in smoothing the video quality compared with the latest two-pass rate control method.

  3. Resistor-logic demultiplexers for nanoelectronics based on constant-weight codes.

    PubMed

    Kuekes, Philip J; Robinett, Warren; Roth, Ron M; Seroussi, Gadiel; Snider, Gregory S; Stanley Williams, R

    2006-02-28

    The voltage margin of a resistor-logic demultiplexer can be improved significantly by basing its connection pattern on a constant-weight code. Each distinct code determines a unique demultiplexer, and therefore a large family of circuits is defined. We consider using these demultiplexers for building nanoscale crossbar memories, and determine the voltage margin of the memory system based on a particular code. We determine a purely code-theoretic criterion for selecting codes that will yield memories with large voltage margins, which is to minimize the ratio of the maximum to the minimum Hamming distance between distinct codewords. For the specific example of a 64 × 64 crossbar, we discuss what codes provide optimal performance for a memory.

  4. On the evolution of primitive genetic codes.

    PubMed

    Weberndorfer, Günter; Hofacker, Ivo L; Stadler, Peter F

    2003-10-01

    The primordial genetic code probably has been a drastically simplified ancestor of the canonical code that is used by contemporary cells. In order to understand how the present-day code came about we first need to explain how the language of the building plan can change without destroying the encoded information. In this work we introduce a minimal organism model that is based on biophysically reasonable descriptions of RNA and protein, namely secondary structure folding and knowledge based potentials. The evolution of a population of such organism under competition for a common resource is simulated explicitly at the level of individual replication events. Starting with very simple codes, and hence greatly reduced amino acid alphabets, we observe a diversification of the codes in most simulation runs. The driving force behind this effect is the possibility to produce fitter proteins when the repertoire of amino acids is enlarged.

  5. Indoor Air Quality Assessment of the San Francisco Federal Building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apte, Michael; Bennett, Deborah H.; Faulkner, David

    2008-07-01

    An assessment of the indoor air quality (IAQ) of the San Francisco Federal Building (SFFB) was conducted on May 12 and 14, 2009 at the request of the General Services Administration (GSA). The purpose of the assessment was for a general screening of IAQ parameters typically indicative of well functioning building systems. One naturally ventilated space and one mechanically ventilated space were studied. In both zones, the levels of indoor air contaminants, including CO2, CO, particulate matter, volatile organic compounds, and aldehydes, were low, relative to reference exposure levels and air quality standards for comparable office buildings. We found slightlymore » elevated levels of volatile organic compounds (VOCs) including two compounds often found in"green" cleaning products. In addition, we found two industrial solvents at levels higher than typically seen in office buildings, but the levels were not sufficient to be of a health concern. The ventilation rates in the two study spaces were high by any standard. Ventilation rates in the building should be further investigated and adjusted to be in line with the building design. Based on our measurements, we conclude that the IAQ is satisfactory in the zone we tested, but IAQ may need to be re-checked after the ventilation rates have been lowered.« less

  6. 47. Historic photo of Building 202 test cell interior, test ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. Historic photo of Building 202 test cell interior, test stand A with technician working on zone injector engine, June 3, 1996. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA photo number C-66-2396. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  7. 78 FR 20852 - Safety Zones; Marine Week Air Ground Demonstration, Lake Washington; Seattle, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-08

    ...-AA00 Safety Zones; Marine Week Air Ground Demonstration, Lake Washington; Seattle, WA AGENCY: Coast... safety zones around vessels and persons involved in the Marine Week Seattle Special Marine Air Ground...: Docket Management Facility (M-30), U.S. Department of Transportation, West Building Ground Floor, Room...

  8. Structural evaluation of the 2736Z Building for seismic loads

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giller, R.A.

    The 2736Z building structure is evaluated for high-hazard loads. The 2736Z building is analyzed herein for normal and seismic loads and is found to successfully meet the guidelines of UCRL-15910 along with the related codes requirements.

  9. 44 CFR 79.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... authorized native organization, that has zoning and building code jurisdiction over a particular area having... of each claim (including building and contents payments) exceeding $5,000, and with the cumulative... (building payments only) have been made under such coverage, with cumulative amount of such claims exceeding...

  10. 44 CFR 79.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... authorized native organization, that has zoning and building code jurisdiction over a particular area having... of each claim (including building and contents payments) exceeding $5,000, and with the cumulative... (building payments only) have been made under such coverage, with cumulative amount of such claims exceeding...

  11. Synthetic building materials for transport buildings and structures

    NASA Astrophysics Data System (ADS)

    Gerasimova, Vera

    2017-10-01

    The most effective building materials account for the highest growth not only in construction of residential and public buildings, but also other capital projects including roadways, bridges, drainage, communications and other engineering projects. Advancement in the technology of more efficient and ecologically responsible insulation materials have been a priority for safety, minimal maintenance and longevity of finished construction projects. The practical use of modern building materials such as insulation, sound reduction and low energy consumption are a benefit in cost and application compared to the use of outdated heavier and labor-intensive materials. The most efficient way for maximizing insolation and sound proofing should be done during the design stages of the project according to existing codes and regulations that are required by Western Government. All methods and materials that are used need to be optimized in order to reach a high durability and low operational and maintenance cost exceeding more than 50 years of the life of the building, whether it is for public, industrial or residential use. Western construction techniques and technologies need to be applied and adapted by the Russian Federation to insure the most productive successful methods are being implemented. The issues of efficient insulation materials are outlined in this article.

  12. NaturAnalogs for the Unsaturated Zone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Simmons; A. Unger; M. Murrell

    2000-03-08

    The purpose of this Analysis/Model Report (AMR) is to document natural and anthropogenic (human-induced) analog sites and processes that are applicable to flow and transport processes expected to occur at the potential Yucca Mountain repository in order to build increased confidence in modeling processes of Unsaturated Zone (UZ) flow and transport. This AMR was prepared in accordance with ''AMR Development Plan for U0135, Natural Analogs for the UZ'' (CRWMS 1999a). Knowledge from analog sites and processes is used as corroborating information to test and build confidence in flow and transport models of Yucca Mountain, Nevada. This AMR supports the Unsaturatedmore » Zone (UZ) Flow and Transport Process Model Report (PMR) and the Yucca Mountain Site Description. The objectives of this AMR are to test and build confidence in the representation of UZ processes in numerical models utilized in the UZ Flow and Transport Model. This is accomplished by: (1) applying data from Boxy Canyon, Idaho in simulations of UZ flow using the same methodologies incorporated in the Yucca Mountain UZ Flow and Transport Model to assess the fracture-matrix interaction conceptual model; (2) Providing a preliminary basis for analysis of radionuclide transport at Pena Blanca, Mexico as an analog of radionuclide transport at Yucca Mountain; and (3) Synthesizing existing information from natural analog studies to provide corroborating evidence for representation of ambient and thermally coupled UZ flow and transport processes in the UZ Model.« less

  13. Analysis of IECC (2003, 2006, 2009) and ASHRAE 90.1-2007 Commercial Energy Code Requirements for Mesa, AZ.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Yunzhi; Gowri, Krishnan

    2011-02-28

    This report summarizes code requirements and energy savings of commercial buildings in Climate Zone 2B built to the 2009 IECC and ASHRAE Standard 90.1-2007 when compared to the 2003 IECC and the 2006 IECC. In general, the 2009 IECC and ASHRAE Standard 90.1-2007 have higher insulation requirements for exterior walls, roof, and windows and have higher efficiency requirements for HVAC equipment. HVAC equipment efficiency requirements are governed by National Appliance Conversion Act of 1987 (NAECA), and are applicable irrespective of the IECC version adopted. The energy analysis results show that commercial buildings meeting the 2009 IECC requirements save 4.4% tomore » 9.5% site energy and 4.1% to 9.9% energy cost when compared to the 2006 IECC; and save 10.6% to 29.4% site energy and 10.3% to 29.3% energy cost when compared to the 2003 IECC. Similar analysis comparing ASHRAE Standard 90.1-2007 requirements to the 2006 IECC shows that the energy savings are in the 4.0% to 10.7% for multi-family and retail buildings, but less than 2% for office buildings. Further comparison of ASHRAE Standard 90.1-2007 requirements to the 2003 IECC show site energy savings in the range of 7.7% to 30.6% and energy cost savings range from 7.9% to 30.3%. Both the 2009 IECC and ASHRAE Standard 90.1-2007 have the potential to save energy by comparable levels for most building types.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in New York. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in New York.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in New Mexico. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in New Mexico.

  16. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Rhode Island

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Rhode Island. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Rhode Island.

  17. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for South Carolina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in South Carolina. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in South Carolina.

  18. NARMER-1: a photon point-kernel code with build-up factors

    NASA Astrophysics Data System (ADS)

    Visonneau, Thierry; Pangault, Laurence; Malouch, Fadhel; Malvagi, Fausto; Dolci, Florence

    2017-09-01

    This paper presents an overview of NARMER-1, the new generation of photon point-kernel code developed by the Reactor Studies and Applied Mathematics Unit (SERMA) at CEA Saclay Center. After a short introduction giving some history points and the current context of development of the code, the paper exposes the principles implemented in the calculation, the physical quantities computed and surveys the generic features: programming language, computer platforms, geometry package, sources description, etc. Moreover, specific and recent features are also detailed: exclusion sphere, tetrahedral meshes, parallel operations. Then some points about verification and validation are presented. Finally we present some tools that can help the user for operations like visualization and pre-treatment.

  19. ClinicalCodes: an online clinical codes repository to improve the validity and reproducibility of research using electronic medical records.

    PubMed

    Springate, David A; Kontopantelis, Evangelos; Ashcroft, Darren M; Olier, Ivan; Parisi, Rosa; Chamapiwa, Edmore; Reeves, David

    2014-01-01

    Lists of clinical codes are the foundation for research undertaken using electronic medical records (EMRs). If clinical code lists are not available, reviewers are unable to determine the validity of research, full study replication is impossible, researchers are unable to make effective comparisons between studies, and the construction of new code lists is subject to much duplication of effort. Despite this, the publication of clinical codes is rarely if ever a requirement for obtaining grants, validating protocols, or publishing research. In a representative sample of 450 EMR primary research articles indexed on PubMed, we found that only 19 (5.1%) were accompanied by a full set of published clinical codes and 32 (8.6%) stated that code lists were available on request. To help address these problems, we have built an online repository where researchers using EMRs can upload and download lists of clinical codes. The repository will enable clinical researchers to better validate EMR studies, build on previous code lists and compare disease definitions across studies. It will also assist health informaticians in replicating database studies, tracking changes in disease definitions or clinical coding practice through time and sharing clinical code information across platforms and data sources as research objects.

  20. ClinicalCodes: An Online Clinical Codes Repository to Improve the Validity and Reproducibility of Research Using Electronic Medical Records

    PubMed Central

    Springate, David A.; Kontopantelis, Evangelos; Ashcroft, Darren M.; Olier, Ivan; Parisi, Rosa; Chamapiwa, Edmore; Reeves, David

    2014-01-01

    Lists of clinical codes are the foundation for research undertaken using electronic medical records (EMRs). If clinical code lists are not available, reviewers are unable to determine the validity of research, full study replication is impossible, researchers are unable to make effective comparisons between studies, and the construction of new code lists is subject to much duplication of effort. Despite this, the publication of clinical codes is rarely if ever a requirement for obtaining grants, validating protocols, or publishing research. In a representative sample of 450 EMR primary research articles indexed on PubMed, we found that only 19 (5.1%) were accompanied by a full set of published clinical codes and 32 (8.6%) stated that code lists were available on request. To help address these problems, we have built an online repository where researchers using EMRs can upload and download lists of clinical codes. The repository will enable clinical researchers to better validate EMR studies, build on previous code lists and compare disease definitions across studies. It will also assist health informaticians in replicating database studies, tracking changes in disease definitions or clinical coding practice through time and sharing clinical code information across platforms and data sources as research objects. PMID:24941260

  1. ANN modeling of DNA sequences: new strategies using DNA shape code.

    PubMed

    Parbhane, R V; Tambe, S S; Kulkarni, B D

    2000-09-01

    Two new encoding strategies, namely, wedge and twist codes, which are based on the DNA helical parameters, are introduced to represent DNA sequences in artificial neural network (ANN)-based modeling of biological systems. The performance of the new coding strategies has been evaluated by conducting three case studies involving mapping (modeling) and classification applications of ANNs. The proposed coding schemes have been compared rigorously and shown to outperform the existing coding strategies especially in situations wherein limited data are available for building the ANN models.

  2. Data on European non-residential buildings.

    PubMed

    D'Agostino, Delia; Cuniberti, Barbara; Bertoldi, Paolo

    2017-10-01

    This data article relates to the research paper Energy consumption and efficiency technology measures in European non-residential buildings (D'Agostino et al., 2017) [1]. The reported data have been collected in the framework of the Green Building Programme that ran from 2006 to 2014. The project has encouraged the adoption of efficiency measures to boost energy savings in European non-residential buildings. Data focus on the one-thousand buildings that joined the Programme allowing to save around 985 GWh/year. The main requirement to join the Programme was the reduction of at least 25% primary energy consumption in a new or retrofitted building. Energy consumption before and after the renovation are provided for retrofitted buildings while, in new constructions, a building had to be designed using at least 25% less energy than requested by the country's building codes. The following data are linked within this article: energy consumption, absolute and relative savings related to primary energy, saving percentages, implemented efficiency measures and renewables. Further information is given about each building in relation to geometry, envelope, materials, lighting and systems.

  3. 78 FR 27906 - Lead; Renovation, Repair, and Painting Program for Public and Commercial Buildings; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-13

    ... construction (NAICS code 236), e.g., commercial building construction, industrial building construction, commercial and institutional building construction, building finishing contractors, drywall and insulation... Lead; Renovation, Repair, and Painting Program for Public and Commercial Buildings; Notice of Public...

  4. Seismic instrumentation of buildings

    USGS Publications Warehouse

    Çelebi, Mehmet

    2000-01-01

    The purpose of this report is to provide information on how and why we deploy seismic instruments in and around building structures. The recorded response data from buildings and other instrumented structures can be and are being primarily used to facilitate necessary studies to improve building codes and therefore reduce losses of life and property during damaging earthquakes. Other uses of such data can be in emergency response situations in large urban environments. The report discusses typical instrumentation schemes, existing instrumentation programs, the steps generally followed in instrumenting a structure, selection and type of instruments, installation and maintenance requirements and data retrieval and processing issues. In addition, a summary section on how recorded response data have been utilized is included. The benefits from instrumentation of structural systems are discussed.

  5. 48. Historic photo of Building 202 test cell interior, test ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. Historic photo of Building 202 test cell interior, test stand A with zone injector engine; technician is working on equipment panel in foreground, June 3, 1966. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA photo number C-66-2397. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  6. Esprit de Place: Maintaining and Designing Library Buildings To Provide Transcendent Spaces.

    ERIC Educational Resources Information Center

    Demas, Sam; Scherer, Jeffrey A.

    2002-01-01

    Discusses library buildings and their role in building community. Reviews current design trends, including reading and study spaces; collaborative workspaces; technology-free zones; archives and special collections; cultural events spaces; age-specific spaces; shared spaces; natural light and landscapes; and interior design trends. (LRW)

  7. Subgrid Scale Modeling in Solar Convection Simulations using the ASH Code

    NASA Technical Reports Server (NTRS)

    Young, Y.-N.; Miesch, M.; Mansour, N. N.

    2003-01-01

    The turbulent solar convection zone has remained one of the most challenging and important subjects in physics. Understanding the complex dynamics in the solar con- vection zone is crucial for gaining insight into the solar dynamo problem. Many solar observatories have generated revealing data with great details of large scale motions in the solar convection zone. For example, a strong di erential rotation is observed: the angular rotation is observed to be faster at the equator than near the poles not only near the solar surface, but also deep in the convection zone. On the other hand, due to the wide range of dynamical scales of turbulence in the solar convection zone, both theory and simulation have limited success. Thus, cutting edge solar models and numerical simulations of the solar convection zone have focused more narrowly on a few key features of the solar convection zone, such as the time-averaged di erential rotation. For example, Brun & Toomre (2002) report computational finding of differential rotation in an anelastic model for solar convection. A critical shortcoming in this model is that the viscous dissipation is based on application of mixing length theory to stellar dynamics with some ad hoc parameter tuning. The goal of our work is to implement the subgrid scale model developed at CTR into the solar simulation code and examine how the differential rotation will be a affected as a result. Specifically, we implement a Smagorinsky-Lilly subgrid scale model into the ASH (anelastic spherical harmonic) code developed over the years by various authors. This paper is organized as follows. In x2 we briefly formulate the anelastic system that describes the solar convection. In x3 we formulate the Smagorinsky-Lilly subgrid scale model for unstably stratifed convection. We then present some preliminary results in x4, where we also provide some conclusions and future directions.

  8. "AfterZone:" Outcomes for Youth Participating in Providence's Citywide After-School System. Executive Summary

    ERIC Educational Resources Information Center

    Kauh, Tina J.

    2011-01-01

    This executive summary highlights the main findings from our participation and outcomes analysis of the "AfterZone" initiative--a citywide system-building effort in Providence, Rhode Island, that aims to provide high-quality, accessible out-of-school-time services to middle school youth. The summary briefly defines the AfterZone's unique…

  9. AN EXACT SOLUTION FOR THE ASSESSMENT OF NONEQUILIBRIUM SORPTION OF RADIONUCLIDES IN THE VADOSE ZONE

    EPA Science Inventory

    In a report on model evaluation, the authors ran the HYDRUS Code, among other transport codes, to evaluate the impacts of nonequilibrium sorption sites on the time-evolution of 99Tc and 90Sr through the vadose zone. Since our evaluation was based on a rather low, annual recharge...

  10. LOFT. "Exploded view" of loft containment building (TAN650), including control ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOFT. "Exploded view" of loft containment building (TAN-650), including control building (TAN-630). EG&G. February 1979. INEEL index code no. 036-010-65-220-209565 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  11. Effectiveness of damped braces to mitigate seismic torsional response of unsymmetric-plan buildings

    NASA Astrophysics Data System (ADS)

    Mazza, Fabio; Pedace, Emilia; Favero, Francesco Del

    2017-02-01

    The seismic retrofitting of unsymmetric-plan reinforced concrete (r.c.) framed buildings can be carried out by the incorporation of damped braces (DBs). Yet most of the proposals to mitigate the seismic response of asymmetric framed buildings by DBs rest on the hypothesis of elastic (linear) structural response. The aim of the present work is to evaluate the effectiveness and reliability of a Displacement-Based Design procedure of hysteretic damped braces (HYDBs) based on the nonlinear behavior of the frame members, which adopts the extended N2 method considered by Eurocode 8 to evaluate the higher mode torsional effects. The Town Hall of Spilinga (Italy), a framed structure with an L-shaped plan built at the beginning of the 1960s, is supposed to be retrofitted with HYDBs to attain performance levels imposed by the Italian seismic code (NTC08) in a high-risk zone. Ten structural solutions are compared by considering two in-plan distributions of the HYDBs, to eliminate (elastic) torsional effects, and different design values of the frame ductility combined with a constant design value of the damper ductility. A computer code for the nonlinear dynamic analysis of r.c. spatial framed structures is adopted to evaluate the critical incident angle of bidirectional earthquakes. Beams and columns are simulated with a lumped plasticity model, including flat surface modeling of the axial load-biaxial bending moment elastic domain at the end sections, while a bilinear law is used to idealize the behavior of the HYDBs. Damage index domains are adopted to estimate the directions of least seismic capacity, considering artificial earthquakes whose response spectra match those adopted by NTC08 at serviceability and ultimate limit states.

  12. Implementing energy standards for motors and buildings in the Philippines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiel, S.; Busch, J.; Sanchez, C.

    1998-07-01

    The Philippines' master plan for energy makes cornerstones of energy standards for appliances, buildings, and motors in their energy efficiency effort. Significant progress has been made in implementing appliance standards for some products, but has lagged for others. This has been partly because the resources allocated have dictated a cautious deliberate approach. Products where there has been a lack of information about the respective markets have received lowest priority. Motors fall in this latter category. In their development of building codes, the Philippine government has also taken a cautious deliberate approach and is just now attending to the compliance ofmore » a commercial building energy performance standard that was enacted into law in 1994. This paper describes the results of recent new buildings and motor market assessments carried out in the Philippines, a survey of building energy code implementation in other countries, and how these products are being used to further implementation of energy standards in the Philippines. Lessons for other countries are drawn from this experience.« less

  13. Investigation of Near Shannon Limit Coding Schemes

    NASA Technical Reports Server (NTRS)

    Kwatra, S. C.; Kim, J.; Mo, Fan

    1999-01-01

    Turbo codes can deliver performance that is very close to the Shannon limit. This report investigates algorithms for convolutional turbo codes and block turbo codes. Both coding schemes can achieve performance near Shannon limit. The performance of the schemes is obtained using computer simulations. There are three sections in this report. First section is the introduction. The fundamental knowledge about coding, block coding and convolutional coding is discussed. In the second section, the basic concepts of convolutional turbo codes are introduced and the performance of turbo codes, especially high rate turbo codes, is provided from the simulation results. After introducing all the parameters that help turbo codes achieve such a good performance, it is concluded that output weight distribution should be the main consideration in designing turbo codes. Based on the output weight distribution, the performance bounds for turbo codes are given. Then, the relationships between the output weight distribution and the factors like generator polynomial, interleaver and puncturing pattern are examined. The criterion for the best selection of system components is provided. The puncturing pattern algorithm is discussed in detail. Different puncturing patterns are compared for each high rate. For most of the high rate codes, the puncturing pattern does not show any significant effect on the code performance if pseudo - random interleaver is used in the system. For some special rate codes with poor performance, an alternative puncturing algorithm is designed which restores their performance close to the Shannon limit. Finally, in section three, for iterative decoding of block codes, the method of building trellis for block codes, the structure of the iterative decoding system and the calculation of extrinsic values are discussed.

  14. Analysis for Building Envelopes and Mechanical Systems Using 2012 CBECS Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winiarski, David W.; Halverson, Mark A.; Butzbaugh, Joshua B.

    This report describes the aggregation and mapping of certain building characteristics data available in the most recent Commercial Building Energy Consumption Survey (CBECS) (DOE EIA 2012) to describe most typical building construction practices. This report provides summary data for potential use in the support of modifications to the Pacific Northwest National Laboratory’s commercial building prototypes used for building energy code analysis. Specifically, this report outlines findings and most typical design choices for certain building envelope and heating, ventilating, and air-conditioning (HVAC) system choices.

  15. Fusion PIC code performance analysis on the Cori KNL system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koskela, Tuomas S.; Deslippe, Jack; Friesen, Brian

    We study the attainable performance of Particle-In-Cell codes on the Cori KNL system by analyzing a miniature particle push application based on the fusion PIC code XGC1. We start from the most basic building blocks of a PIC code and build up the complexity to identify the kernels that cost the most in performance and focus optimization efforts there. Particle push kernels operate at high AI and are not likely to be memory bandwidth or even cache bandwidth bound on KNL. Therefore, we see only minor benefits from the high bandwidth memory available on KNL, and achieving good vectorization ismore » shown to be the most beneficial optimization path with theoretical yield of up to 8x speedup on KNL. In practice we are able to obtain up to a 4x gain from vectorization due to limitations set by the data layout and memory latency.« less

  16. Building America FY 2016 Annual Report: Building America Is Driving Real Solutions in the Race to Zero Energy Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farrar, Sara; Rothgeb, Stacey; Polly, Ben

    The U.S. Department of Energy (DOE) Building America Program enables the transformation of the U.S. housing industry to achieve energy savings through energy-efficient, high-performance homes with improved durability, comfort, and health for occupants. Building America bridges the gap between the development of emerging technologies and the adoption of codes and standards by engaging industry partners in applied research, development, and demonstration of high-performance solutions.

  17. 38 CFR 36.4701 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... political subdivision of a State that has zoning and building code jurisdiction over a particular area having special flood hazards. (e) Designated loan means a loan secured by a building or mobile home that... of Veterans Affairs. (c) Building means a walled and roofed structure, other than a gas or liquid...

  18. 38 CFR 36.4701 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... political subdivision of a State that has zoning and building code jurisdiction over a particular area having special flood hazards. (e) Designated loan means a loan secured by a building or mobile home that... of Veterans Affairs. (c) Building means a walled and roofed structure, other than a gas or liquid...

  19. 38 CFR 36.4701 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... political subdivision of a State that has zoning and building code jurisdiction over a particular area having special flood hazards. (e) Designated loan means a loan secured by a building or mobile home that... of Veterans Affairs. (c) Building means a walled and roofed structure, other than a gas or liquid...

  20. 38 CFR 36.4701 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... political subdivision of a State that has zoning and building code jurisdiction over a particular area having special flood hazards. (e) Designated loan means a loan secured by a building or mobile home that... of Veterans Affairs. (c) Building means a walled and roofed structure, other than a gas or liquid...

  1. The development of fire evaluation system for detention and correctional occupancies

    NASA Astrophysics Data System (ADS)

    Nelson, H. E.; Shibe, A. J.

    1984-12-01

    A fire safety evaluation system for detention and correctional occupancies was developed. It can be used for determining if a facility has fire safety equivalent to that obtained by meeting the requirement of a given code. The system was calibrated for use with proposed chapters for detention and correctional occupancies of the Life Safety Code (1985). There are separate sets of requirements for each of four use conditions: one for zoned egress, one for zoned impeded egress, one for impeded egress, and one for contained. Within each set, there are two levels of evaluation: one for partially sprinklered and nonsprinklered buildings, and one for totally sprinklered buildings.

  2. A Clustering-Based Approach to Enriching Code Foraging Environment.

    PubMed

    Niu, Nan; Jin, Xiaoyu; Niu, Zhendong; Cheng, Jing-Ru C; Li, Ling; Kataev, Mikhail Yu

    2016-09-01

    Developers often spend valuable time navigating and seeking relevant code in software maintenance. Currently, there is a lack of theoretical foundations to guide tool design and evaluation to best shape the code base to developers. This paper contributes a unified code navigation theory in light of the optimal food-foraging principles. We further develop a novel framework for automatically assessing the foraging mechanisms in the context of program investigation. We use the framework to examine to what extent the clustering of software entities affects code foraging. Our quantitative analysis of long-lived open-source projects suggests that clustering enriches the software environment and improves foraging efficiency. Our qualitative inquiry reveals concrete insights into real developer's behavior. Our research opens the avenue toward building a new set of ecologically valid code navigation tools.

  3. Mitigating shear lag in tall buildings

    NASA Astrophysics Data System (ADS)

    Gaur, Himanshu; Goliya, Ravindra K.

    2015-09-01

    As the height of building increases, effect of shear lag also becomes considerable in the design of high-rise buildings. In this paper, shear lag effect in tall buildings of heights, i.e., 120, 96, 72, 48 and 36 stories of which aspect ratio ranges from 3 to 10 is studied. Tube-in-tube structural system with façade bracing is used for designing the building of height 120 story. It is found that bracing system considerably reduces the shear lag effect and hence increases the building stiffness to withstand lateral loads. Different geometric patterns of bracing system are considered. The best effective geometric configuration of bracing system is concluded in this study. Lateral force, as wind load is applied on the buildings as it is the most dominating lateral force for such heights. Wind load is set as per Indian standard code of practice IS 875 Part-3. For analysis purpose SAP 2000 software program is used.

  4. Globalisation Reflected onto Architecture: Tall Buildings of Ankara-Turkey

    NASA Astrophysics Data System (ADS)

    Tanju Gültekin, Ahmet

    2017-10-01

    Policy switching, radical socioeconomic changes, integration and globalisation were started in 1980s. New urban space developments have been accelerated in 1990s and provided urban space identity policies in 2000s. Luxurious shopping malls, hotels, and ultra-posh residences within the city and gated communities on city peripheries have been formed. Thus, the urban geography, urban silhouette and urban identity are being converted through tall buildings that signify the created prestige, status, and power in competition with the global capital. By the globalisation foresight the cities which have gotten ahead of the nation-state was seen. The buildings that converted into a symbolic (iconic) global product leads to an advantage in the race for attracting global investments and tourism, on behalf of the cities/urban districts. This process, which was initiated haphazardly in Turkey in the 1980s, has been on-going throughout the 1990s and especially in 2000s by means of the re-structuring of the government on a neo-liberal basis. The process is concurrently observable through the tall buildings and/or building blocks which match with urban regeneration projects, urban zoning plan revisions and fragmented zoning plans. In this study, the new global world order is evaluated by their status and architectural properties of selected tall and iconic/ultra-modern buildings in Ankara.

  5. Establishing a commercial building energy data framework for India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iyer, Maithili; Kumar, Satish; Mathew, Sangeeta

    Buildings account for over 40% of the world’s energy consumption and are therefore a key contributor to a country’s energy as well as carbon budget. Understanding how buildings use energy is critical to understanding how related policies may impact energy use. Data enables decision making, and good quality data arms consumers with the tools to compare their energy performance to their peers, allowing them to differentiate their buildings in the real estate market on the basis of their energy footprint. Good quality data are also essential for policy makers to prioritize their energy saving strategies and track implementation. The Unitedmore » States’ Commercial Building Energy Consumption Survey (CBECS) is an example of a successful data framework that is highly useful for governmental and nongovernmental initiatives related to benchmarking energy forecasting, rating systems and metrics, and more. The Bureau of Energy Efficiency (BEE) in India developed the Energy Conservation Building Code (ECBC) and launched the Star Labeling program for a few energy-intensive building segments as a significant first step. However, a data driven policy framework for systematically targeting energy efficiency in both new construction and existing buildings has largely been missing. There is no quantifiable mechanism currently in place to track the impact of code adoption through regular reporting/survey of energy consumption in the commercial building stock. In this paper we present findings from our study that explored use cases and approaches for establishing a commercial buildings data framework for India.« less

  6. Soft-Input Soft-Output Modules for the Construction and Distributed Iterative Decoding of Code Networks

    NASA Technical Reports Server (NTRS)

    Benedetto, S.; Divsalar, D.; Montorsi, G.; Pollara, F.

    1998-01-01

    Soft-input soft-output building blocks (modules) are presented to construct and iteratively decode in a distributed fashion code networks, a new concept that includes, and generalizes, various forms of concatenated coding schemes.

  7. ASME Code Efforts Supporting HTGRs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D.K. Morton

    2010-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This reportmore » discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.« less

  8. ASME Code Efforts Supporting HTGRs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D.K. Morton

    2011-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This reportmore » discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.« less

  9. ASME Code Efforts Supporting HTGRs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D.K. Morton

    2012-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This reportmore » discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.« less

  10. Data Collection Handbook to Support Modeling Impacts of Radioactive Material in Soil and Building Structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Charley; Kamboj, Sunita; Wang, Cheng

    2015-09-01

    This handbook is an update of the 1993 version of the Data Collection Handbook and the Radionuclide Transfer Factors Report to support modeling the impact of radioactive material in soil. Many new parameters have been added to the RESRAD Family of Codes, and new measurement methodologies are available. A detailed review of available parameter databases was conducted in preparation of this new handbook. This handbook is a companion document to the user manuals when using the RESRAD (onsite) and RESRAD-OFFSITE code. It can also be used for RESRAD-BUILD code because some of the building-related parameters are included in this handbook.more » The RESRAD (onsite) has been developed for implementing U.S. Department of Energy Residual Radioactive Material Guidelines. Hydrogeological, meteorological, geochemical, geometrical (size, area, depth), crops and livestock, human intake, source characteristic, and building characteristic parameters are used in the RESRAD (onsite) code. The RESRAD-OFFSITE code is an extension of the RESRAD (onsite) code and can also model the transport of radionuclides to locations outside the footprint of the primary contamination. This handbook discusses parameter definitions, typical ranges, variations, and measurement methodologies. It also provides references for sources of additional information. Although this handbook was developed primarily to support the application of RESRAD Family of Codes, the discussions and values are valid for use of other pathway analysis models and codes.« less

  11. BEYOND GREEN BUILDINGS: AN INTEGRATED HOLISTIC DESIGN APPROACH

    EPA Science Inventory

    Technical Challenge: The Urban Sustainable Infrastructure Engineering Program (USIEP) at the University of Colorado at Denver is designing a Sustainable Youth Zone (SYZ) building in a disadvantaged community in Commerce City, CO. The SYZ utilizes a holistic ...

  12. Deciphering the transcriptional cis-regulatory code.

    PubMed

    Yáñez-Cuna, J Omar; Kvon, Evgeny Z; Stark, Alexander

    2013-01-01

    Information about developmental gene expression resides in defined regulatory elements, called enhancers, in the non-coding part of the genome. Although cells reliably utilize enhancers to orchestrate gene expression, a cis-regulatory code that would allow their interpretation has remained one of the greatest challenges of modern biology. In this review, we summarize studies from the past three decades that describe progress towards revealing the properties of enhancers and discuss how recent approaches are providing unprecedented insights into regulatory elements in animal genomes. Over the next years, we believe that the functional characterization of regulatory sequences in entire genomes, combined with recent computational methods, will provide a comprehensive view of genomic regulatory elements and their building blocks and will enable researchers to begin to understand the sequence basis of the cis-regulatory code. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Abstract feature codes: The building blocks of the implicit learning system.

    PubMed

    Eberhardt, Katharina; Esser, Sarah; Haider, Hilde

    2017-07-01

    According to the Theory of Event Coding (TEC; Hommel, Müsseler, Aschersleben, & Prinz, 2001), action and perception are represented in a shared format in the cognitive system by means of feature codes. In implicit sequence learning research, it is still common to make a conceptual difference between independent motor and perceptual sequences. This supposedly independent learning takes place in encapsulated modules (Keele, Ivry, Mayr, Hazeltine, & Heuer 2003) that process information along single dimensions. These dimensions have remained underspecified so far. It is especially not clear whether stimulus and response characteristics are processed in separate modules. Here, we suggest that feature dimensions as they are described in the TEC should be viewed as the basic content of modules of implicit learning. This means that the modules process all stimulus and response information related to certain feature dimensions of the perceptual environment. In 3 experiments, we investigated by means of a serial reaction time task the nature of the basic units of implicit learning. As a test case, we used stimulus location sequence learning. The results show that a stimulus location sequence and a response location sequence cannot be learned without interference (Experiment 2) unless one of the sequences can be coded via an alternative, nonspatial dimension (Experiment 3). These results support the notion that spatial location is one module of the implicit learning system and, consequently, that there are no separate processing units for stimulus versus response locations. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  14. Landslide Risk: Economic Valuation in The North-Eastern Zone of Medellin City

    NASA Astrophysics Data System (ADS)

    Vega, Johnny Alexander; Hidalgo, César Augusto; Johana Marín, Nini

    2017-10-01

    Natural disasters of a geodynamic nature can cause enormous economic and human losses. The economic costs of a landslide disaster include relocation of communities and physical repair of urban infrastructure. However, when performing a quantitative risk analysis, generally, the indirect economic consequences of such an event are not taken into account. A probabilistic approach methodology that considers several scenarios of hazard and vulnerability to measure the magnitude of the landslide and to quantify the economic costs is proposed. With this approach, it is possible to carry out a quantitative evaluation of the risk by landslides, allowing the calculation of the economic losses before a potential disaster in an objective, standardized and reproducible way, taking into account the uncertainty of the building costs in the study zone. The possibility of comparing different scenarios facilitates the urban planning process, the optimization of interventions to reduce risk to acceptable levels and an assessment of economic losses according to the magnitude of the damage. For the development and explanation of the proposed methodology, a simple case study is presented, located in north-eastern zone of the city of Medellín. This area has particular geomorphological characteristics, and it is also characterized by the presence of several buildings in bad structural conditions. The proposed methodology permits to obtain an estimative of the probable economic losses by earthquake-induced landslides, taking into account the uncertainty of the building costs in the study zone. The obtained estimative shows that the structural intervention of the buildings produces a reduction the order of 21 % in the total landslide risk.

  15. Visualising higher order Brillouin zones with applications

    NASA Astrophysics Data System (ADS)

    Andrew, R. C.; Salagaram, T.; Chetty, N.

    2017-05-01

    A key concept in material science is the relationship between the Bravais lattice, the reciprocal lattice and the resulting Brillouin zones (BZ). These zones are often complicated shapes that are hard to construct and visualise without the use of sophisticated software, even by professional scientists. We have used a simple sorting algorithm to construct BZ of any order for a chosen Bravais lattice that is easy to implement in any scientific programming language. The resulting zones can then be visualised using freely available plotting software. This method has pedagogical value for upper-level undergraduate students since, along with other computational methods, it can be used to illustrate how constant-energy surfaces combine with these zones to create van Hove singularities in the density of states. In this paper we apply our algorithm along with the empirical pseudopotential method and the 2D equivalent of the tetrahedron method to show how they can be used in a simple software project to investigate this interaction for a 2D crystal. This project not only enhances students’ fundamental understanding of the principles involved but also improves transferable coding skills.

  16. Tsunami risk zoning in south-central Chile

    NASA Astrophysics Data System (ADS)

    Lagos, M.

    2010-12-01

    The recent 2010 Chilean tsunami revealed the need to optimize methodologies for assessing the risk of disaster. In this context, modern techniques and criteria for the evaluation of the tsunami phenomenon were applied in the coastal zone of south-central Chile as a specific methodology for the zoning of tsunami risk. This methodology allows the identification and validation of a scenario of tsunami hazard; the spatialization of factors that have an impact on the risk; and the zoning of the tsunami risk. For the hazard evaluation, different scenarios were modeled by means of numerical simulation techniques, selecting and validating the results that better fit with the observed tsunami data. Hydrodynamic parameters of the inundation as well as physical and socioeconomic vulnerability aspects were considered for the spatialization of the factors that affect the tsunami risk. The tsunami risk zoning was integrated into a Geographic Information System (GIS) by means of multicriteria evaluation (MCE). The results of the tsunami risk zoning show that the local characteristics and their location, together with the concentration of poverty levels, establish spatial differentiated risk levels. This information builds the basis for future applied studies in land use planning that tend to minimize the risk levels associated to the tsunami hazard. This research is supported by Fondecyt 11090210.

  17. THE RETC CODE FOR QUANTIFYING THE HYDRAULIC FUNCTIONS OF UNSATURATED SOILS

    EPA Science Inventory

    This report describes the RETC computer code for analyzing the soil water retention and hydraulic conductivity functions of unsaturated soils. These hydraulic properties are key parameters in any quantitative description of water flow into and through the unsaturated zone of soil...

  18. Building Interactive Simulations in Web Pages without Programming.

    PubMed

    Mailen Kootsey, J; McAuley, Grant; Bernal, Julie

    2005-01-01

    A software system is described for building interactive simulations and other numerical calculations in Web pages. The system is based on a new Java-based software architecture named NumberLinX (NLX) that isolates each function required to build the simulation so that a library of reusable objects could be assembled. The NLX objects are integrated into a commercial Web design program for coding-free page construction. The model description is entered through a wizard-like utility program that also functions as a model editor. The complete system permits very rapid construction of interactive simulations without coding. A wide range of applications are possible with the system beyond interactive calculations, including remote data collection and processing and collaboration over a network.

  19. The detection and extraction of interleaved code segments

    NASA Technical Reports Server (NTRS)

    Rugaber, Spencer; Stirewalt, Kurt; Wills, Linda M.

    1995-01-01

    This project is concerned with a specific difficulty that arises when trying to understand and modify computer programs. In particular, it is concerned with the phenomenon of 'interleaving' in which one section of a program accomplishes several purposes, and disentangling the code responsible for each purposes is difficult. Unraveling interleaved code involves discovering the purpose of each strand of computation, as well as understanding why the programmer decided to interleave the strands. Increased understanding improve the productivity and quality of software maintenance, enhancement, and documentation activities. It is the goal of the project to characterize the phenomenon of interleaving as a prerequisite for building tools to detect and extract interleaved code fragments.

  20. Looking West From rear (East) End of Office Building Including ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking West From rear (East) End of Office Building Including Recycle Storage Area, Loading Docks, and Decontamination Zone - Hematite Fuel Fabrication Facility, Office, 3300 State Road P, Festus, Jefferson County, MO

  1. Thermal impact of magmatism in subduction zones

    NASA Astrophysics Data System (ADS)

    Rees Jones, David W.; Katz, Richard F.; Tian, Meng; Rudge, John F.

    2018-01-01

    Magmatism in subduction zones builds continental crust and causes most of Earth's subaerial volcanism. The production rate and composition of magmas are controlled by the thermal structure of subduction zones. A range of geochemical and heat flow evidence has recently converged to indicate that subduction zones are hotter at lithospheric depths beneath the arc than predicted by canonical thermomechanical models, which neglect magmatism. We show that this discrepancy can be resolved by consideration of the heat transported by magma. In our one- and two-dimensional numerical models and scaling analysis, magmatic transport of sensible and latent heat locally alters the thermal structure of canonical models by ∼300 K, increasing predicted surface heat flow and mid-lithospheric temperatures to observed values. We find the advection of sensible heat to be larger than the deposition of latent heat. Based on these results we conclude that thermal transport by magma migration affects the chemistry and the location of arc volcanoes.

  2. The study on dynamic cadastral coding rules based on kinship relationship

    NASA Astrophysics Data System (ADS)

    Xu, Huan; Liu, Nan; Liu, Renyi; Lu, Jingfeng

    2007-06-01

    Cadastral coding rules are an important supplement to the existing national and local standard specifications for building cadastral database. After analyzing the course of cadastral change, especially the parcel change with the method of object-oriented analysis, a set of dynamic cadastral coding rules based on kinship relationship corresponding to the cadastral change is put forward and a coding format composed of street code, block code, father parcel code, child parcel code and grandchild parcel code is worked out within the county administrative area. The coding rule has been applied to the development of an urban cadastral information system called "ReGIS", which is not only able to figure out the cadastral code automatically according to both the type of parcel change and the coding rules, but also capable of checking out whether the code is spatiotemporally unique before the parcel is stored in the database. The system has been used in several cities of Zhejiang Province and got a favorable response. This verifies the feasibility and effectiveness of the coding rules to some extent.

  3. Building and Home Maintenance Services.

    ERIC Educational Resources Information Center

    Michigan State Univ., East Lansing. Coll. of Agriculture and Natural Resources Education Inst.

    This task-based curriculum guide for building and home maintenance services is intended to help the teacher develop a classroom management system where students learn by doing. Introductory materials include a Dictionary of Occupational Titles job code and title sheet, a career ladder, a matrix relating duty/task numbers to job titles, and a task…

  4. 12 CFR 572.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... zoning and building code jurisdiction over a particular area having special flood hazards. (e) Designated loan means a loan secured by a building or mobile home that is located or to be located in a special...) Building means a walled and roofed structure, other than a gas or liquid storage tank, that is principally...

  5. 50 CFR Table 4 to Part 680 - Crab Process Codes

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Crab Process Codes 4 Table 4 to Part 680 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) SHELLFISH FISHERIES OF THE EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 680...

  6. 130. ARAII Administration building (ARA613) vicinity map and plot plan ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    130. ARA-II Administration building (ARA-613) vicinity map and plot plan showing relationship to other existing buildings on site and to ARA-602, to which this building was attached. F.C. Torkelson Comapny 842-area/SL-1-101-U-1. Date: October 1959. Ineel index code no. 070-0101-65-851-150053. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  7. 10 CFR 434.516 - Building exterior envelope.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Proposed Design, the envelope characteristics of the Proposed Design shall be used. 516.2 Infiltration. For Prototype and Reference Buildings, the infiltration assumptions in subsection 516.2.1 shall be prescribed.... Infiltration shall impact perimeter zones only. 516.2.1 When the HVAC system is switched “on,” no infiltration...

  8. 50 CFR Table 3c to Part 680 - Crab Product Codes for Economic Data Reports

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Crab Product Codes for Economic Data Reports 3c Table 3c to Part 680 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL... EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 680, Table 3c Table 3c to Part 680—Crab Product Codes for Economic...

  9. 50 CFR Table 3c to Part 680 - Crab Product Codes for Economic Data Reports

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 13 2012-10-01 2012-10-01 false Crab Product Codes for Economic Data Reports 3c Table 3c to Part 680 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL... EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 680, Table 3c Table 3c to Part 680—Crab Product Codes for Economic...

  10. 50 CFR Table 3c to Part 680 - Crab Product Codes for Economic Data Reports

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 11 2011-10-01 2011-10-01 false Crab Product Codes for Economic Data Reports 3c Table 3c to Part 680 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL... EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 680, Table 3c Table 3c to Part 680—Crab Product Codes for Economic...

  11. Zone descriptions and response characterization for CLF/CLTD calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sowell, E.F.; Chiles, D.C.

    1985-01-01

    This paper presents the results of an extensive parametric study of the dynamic response of building cooling loads to heat gains. These results are in the form of tables that classify zones in terms of seven of their physical properties and according to their dynamic response characteristics. Weighting factors and other data are also given. The principal application of these results will be to allow calculation of tables of Cooling Load Temperature Differences (CLTDs) and Cooling Load Factors (CLFs) for a small number of representative zones that cover the wide range of zones found in practice. Additionally, they will allowmore » for adjustment to the solar CLFs in the ASHRAE Handbook -1981 Fundamentals to account for carpets, room size, ceiling and exterior wall weight.« less

  12. Providing pressure inputs to multizone building models

    DOE PAGES

    Herring, Steven J.; Batchelor, Simon; Bieringer, Paul E.; ...

    2016-02-13

    A study to assess how the fidelity of wind pressure inputs and indoor model complexity affect the predicted air change rate for a study building is presented. The purpose of the work is to support the development of a combined indoor-outdoor hazard prediction tool, which links the CONTAM multizone building simulation tool with outdoor dispersion models. The study building, representing a large office block of a simple rectangular geometry under natural ventilation, was based on a real building used in the Joint Urban 2003 experiment. A total of 1600 indoor model flow simulations were made, driven by 100 meteorological conditionsmore » which provided a wide range of building surface pressures. These pressures were applied at four levels of resolution to four different building configurations with varying numbers of internal zones and indoor and outdoor flow paths. Analysis of the results suggests that surface pressures and flow paths across the envelope should be specified at a resolution consistent with the dimensions of the smallest volume of interest, to ensure that appropriate outputs are obtained.« less

  13. General view of building in context showing row of residences ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    General view of building in context showing row of residences adjacent to golf course, facing northeast. - Marine Barracks, Panama Canal, Officers' Quarters, 800' West of Bruja Road, Balboa, Former Panama Canal Zone, CZ

  14. General view of building in context showing row of residences ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    General view of building in context showing row of residences on Canfield Avenue, facing northwest. - Albrook Air Force Station, Company Officer's Quarters, East side of Canfield Avenue, Balboa, Former Panama Canal Zone, CZ

  15. Reply to “Comment on “Should Memphis build for California's earthquakes?” From A.D. Frankel”

    NASA Astrophysics Data System (ADS)

    Stein, Seth; Tomasello, Joseph; Newman, Andrew

    Carl Sagan observed that “extraordinary claims require extraordinary evidence.” In our view, A.D. Frankel's arguments (see accompanying Comment piece) do not reach the level required to demonstrate the counter-intuitive propositions that the earthquake hazard in the New Madrid Seismic Zone (NMSZ) is comparable to that in coastal California, and that buildings should be built to similar standards.This interchange is the latest in an ongoing debate beginning with Newman et al.'s [1999a] recommendation, based on analysis of Global Positioning System and earthquake data, that Frankel et al.'s [1996] estimate of California-level seismic hazard for the NMSZ should be reduced. Most points at issue, except for those related to the costs and benefits of the proposed new International Building Code 2000, have already been argued at length by both sides in the literature [e.g.,Schweig et al., 1999; Newman et al., 1999b, 2001; Cramer, 2001]. Hence,rather than rehash these points, we will try here to provide readers not enmeshed in this morass with an overview of the primary differences between our view and that of Frankel.

  16. The grout/glass performance assessment code system (GPACS) with verification and benchmarking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piepho, M.G.; Sutherland, W.H.; Rittmann, P.D.

    1994-12-01

    GPACS is a computer code system for calculating water flow (unsaturated or saturated), solute transport, and human doses due to the slow release of contaminants from a waste form (in particular grout or glass) through an engineered system and through a vadose zone to an aquifer, well and river. This dual-purpose document is intended to serve as a user`s guide and verification/benchmark document for the Grout/Glass Performance Assessment Code system (GPACS). GPACS can be used for low-level-waste (LLW) Glass Performance Assessment and many other applications including other low-level-waste performance assessments and risk assessments. Based on all the cses presented, GPACSmore » is adequate (verified) for calculating water flow and contaminant transport in unsaturated-zone sediments and for calculating human doses via the groundwater pathway.« less

  17. Importance biasing scheme implemented in the PRIZMA code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kandiev, I.Z.; Malyshkin, G.N.

    1997-12-31

    PRIZMA code is intended for Monte Carlo calculations of linear radiation transport problems. The code has wide capabilities to describe geometry, sources, material composition, and to obtain parameters specified by user. There is a capability to calculate path of particle cascade (including neutrons, photons, electrons, positrons and heavy charged particles) taking into account possible transmutations. Importance biasing scheme was implemented to solve the problems which require calculation of functionals related to small probabilities (for example, problems of protection against radiation, problems of detection, etc.). The scheme enables to adapt trajectory building algorithm to problem peculiarities.

  18. Solar-heated and cooled savings and loan building-1-Leavenworth, Kanasas

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Report describes heating and cooling system which furnishes 90 percent of annual heating load, 70 percent of cooling load, and all hot water for two-story building. Roof-mounted flat-plate collectors allow three distinct flow rates and are oriented south for optimum energy collection. Building contains fully automated temperature controls is divided into five temperature-load zones, each with independent heat pump.

  19. A High-Granularity Approach to Modeling Energy Consumption and Savings Potential in the U.S. Residential Building Stock

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper willmore » describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.« less

  20. Standardized reporting using CODES (Crash Outcome Data Evaluation System)

    DOT National Transportation Integrated Search

    1999-12-01

    While CODES projects have expanded to 25 states, there is no standardized reporting of the outcome measures that are available with linked data. This paper describes our efforts to build a standard format for reporting these outcomes. This format is ...

  1. Building and design defects observed in the residential sector and the types of damage observed in recent earthquakes in Turkey

    NASA Astrophysics Data System (ADS)

    Tolga Çöğürcü, M.

    2015-01-01

    Turkey is situated in a very active earthquake region. In the last century, several earthquakes resulted in thousands of deaths and enormous economic losses. In 1999, the Marmara earthquake had an approximate death toll of more than 20 000, and in 2011, the Van earthquake killed 604 people. In general, Turkish residential buildings have reinforced concrete structural systems. These reinforced concrete structures have several deficiencies, such as low concrete quality, non-seismic steel detailing, and inappropriate structural systems including several architectural irregularities. In this study, the general characteristics of Turkish building stock and the deficiencies observed in structural systems are explained, and illustrative figures are given with reference to Turkish Earthquake Code 2007 (TEC, 2007). The poor concrete quality, lack of lateral or transverse reinforcement in beam-column joints and column confinement zones, high stirrup spacings, under-reinforced columns and over-reinforced beams are the primary causes of failures. Other deficiencies include weak column-stronger beam formations, insufficient seismic joint separations, soft story or weak story irregularities and short columns. Similar construction and design mistakes are also observed in other countries situated on active earthquake belts. Existing buildings still have these undesirable characteristics, so to prepare for future earthquakes, they must be rehabilitated.

  2. 40 CFR 21.10 - Utilization of the statement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Utilization of the statement. 21.10 Section 21.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL SMALL BUSINESS § 21.10... law, statute, ordinance, or code (including building, health, or zoning codes). (g) An amended...

  3. Associations between county and municipality zoning ordinances and access to fruit and vegetable outlets in rural North Carolina, 2012.

    PubMed

    Mayo, Mariel Leah; Pitts, Stephanie B Jilcott; Chriqui, Jamie F

    2013-12-05

    Zoning ordinances and land-use plans may influence the community food environment by determining placement and access to food outlets, which subsequently support or hinder residents' attempts to eat healthfully. The objective of this study was to examine associations between healthful food zoning scores as derived from information on local zoning ordinances, county demographics, and residents' access to fruit and vegetable outlets in rural northeastern North Carolina. From November 2012 through March 2013, county and municipality zoning ordinances were identified and double-coded by using the Bridging the Gap food code/policy audit form. A healthful food zoning score was derived by assigning points for the allowed use of fruit and vegetable outlets. Pearson coefficients were calculated to examine correlations between the healthful food zoning score, county demographics, and the number of fruit and vegetable outlets. In March and April 2013, qualitative interviews were conducted among county and municipal staff members knowledgeable about local zoning and planning to ascertain implementation and enforcement of zoning to support fruit and vegetable outlets. We found a strong positive correlation between healthful food zoning scores and the number of fruit and vegetable outlets in 13 northeastern North Carolina counties (r = 0.66, P = .01). Major themes in implementation and enforcement of zoning to support fruit and vegetable outlets included strict enforcement versus lack of enforcement of zoning regulations. Increasing the range of permitted uses in zoning districts to include fruit and vegetable outlets may increase access to healthful fruit and vegetable outlets in rural communities.

  4. Associations Between County and Municipality Zoning Ordinances and Access to Fruit And Vegetable Outlets in Rural North Carolina, 2012

    PubMed Central

    Mayo, Mariel Leah; Chriqui, Jamie F.

    2013-01-01

    Introduction Zoning ordinances and land-use plans may influence the community food environment by determining placement and access to food outlets, which subsequently support or hinder residents’ attempts to eat healthfully. The objective of this study was to examine associations between healthful food zoning scores as derived from information on local zoning ordinances, county demographics, and residents’ access to fruit and vegetable outlets in rural northeastern North Carolina. Methods From November 2012 through March 2013, county and municipality zoning ordinances were identified and double-coded by using the Bridging the Gap food code/policy audit form. A healthful food zoning score was derived by assigning points for the allowed use of fruit and vegetable outlets. Pearson coefficients were calculated to examine correlations between the healthful food zoning score, county demographics, and the number of fruit and vegetable outlets. In March and April 2013, qualitative interviews were conducted among county and municipal staff members knowledgeable about local zoning and planning to ascertain implementation and enforcement of zoning to support fruit and vegetable outlets. Results We found a strong positive correlation between healthful food zoning scores and the number of fruit and vegetable outlets in 13 northeastern North Carolina counties (r = 0.66, P = .01). Major themes in implementation and enforcement of zoning to support fruit and vegetable outlets included strict enforcement versus lack of enforcement of zoning regulations. Conclusion Increasing the range of permitted uses in zoning districts to include fruit and vegetable outlets may increase access to healthful fruit and vegetable outlets in rural communities. PMID:24309091

  5. Improving HVAC operational efficiency in small-and medium-size commercial buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Woohyun; Katipamula, Srinivas; Lutes, Robert

    Small- and medium-size (<100,000 sf) commercial buildings (SMBs) represent over 95% of the U.S. commercial building stock and consume over 60% of total site energy consumption. Many of these buildings use rudimentary controls that are mostly manual, with limited scheduling capability, no monitoring, or failure management. Therefore, many of these buildings are operated inefficiently and consume excess energy. SMBs typically use packaged rooftop units (RTUs) that are controlled by an individual thermostat. There is increased urgency to improve the operating efficiency of existing commercial building stock in the United States for many reasons, chief among them being to mitigate themore » climate change impacts. Studies have shown that managing set points and schedules of the RTUs will result in up to 20% energy and cost savings. Another problem associated with RTUs is short cycling, when an RTU goes through ON and OFF cycles too frequently. Excessive cycling can lead to excessive wear and to premature failure of the compressor or its components. Also, short cycling can result in a significantly decreased average efficiency (up to 10%), even if there are no physical failures in the equipment. Ensuring correct use of the zone set points and eliminating frequent cycling of RTUs thereby leading to persistent building operations can significantly increase the operational efficiency of the SMBs. A growing trend is to use low-cost control infrastructure that can enable scalable and cost-effective intelligent building operations. The work reported in this paper describes two algorithms for detecting the zone set point temperature and RTU cycling rate that can be deployed on the low-cost infrastructure. These algorithms only require the zone temperature data for detection. The algorithms have been tested and validated using field data from a number of RTUs from six buildings in different climate locations. Overall, the algorithms were successful in detecting the set points

  6. Exposure calculation code module for reactor core analysis: BURNER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vondy, D.R.; Cunningham, G.W.

    1979-02-01

    The code module BURNER for nuclear reactor exposure calculations is presented. The computer requirements are shown, as are the reference data and interface data file requirements, and the programmed equations and procedure of calculation are described. The operating history of a reactor is followed over the period between solutions of the space, energy neutronics problem. The end-of-period nuclide concentrations are determined given the necessary information. A steady state, continuous fueling model is treated in addition to the usual fixed fuel model. The control options provide flexibility to select among an unusually wide variety of programmed procedures. The code also providesmore » user option to make a number of auxiliary calculations and print such information as the local gamma source, cumulative exposure, and a fine scale power density distribution in a selected zone. The code is used locally in a system for computation which contains the VENTURE diffusion theory neutronics code and other modules.« less

  7. 12 CFR 391.31 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... (d) Community means a State or a political subdivision of a State that has zoning and building code... defined in 12 U.S.C. 1813(b)(3) and any subsidiaries thereof. (c) Building means a walled and roofed... building or mobile home that is located or to be located in a special flood hazard area in which flood...

  8. 12 CFR 391.31 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... (d) Community means a State or a political subdivision of a State that has zoning and building code... defined in 12 U.S.C. 1813(b)(3) and any subsidiaries thereof. (c) Building means a walled and roofed... building or mobile home that is located or to be located in a special flood hazard area in which flood...

  9. SimZones: An Organizational Innovation for Simulation Programs and Centers.

    PubMed

    Roussin, Christopher J; Weinstock, Peter

    2017-08-01

    The complexity and volume of simulation-based learning programs have increased dramatically over the last decade, presenting several major challenges for those who lead and manage simulation programs and centers. The authors present five major issues affecting the organization of simulation programs: (1) supporting both single- and double-loop learning experiences; (2) managing the training of simulation teaching faculty; (3) optimizing the participant mix, including individuals, professional groups, teams, and other role-players, to ensure learning; (4) balancing in situ, node-based, and center-based simulation delivery; and (5) organizing simulation research and measuring value. They then introduce the SimZones innovation, a system of organization for simulation-based learning, and explain how it can alleviate the problems associated with these five issues.Simulations are divided into four zones (Zones 0-3). Zone 0 simulations include autofeedback exercises typically practiced by solitary learners, often using virtual simulation technology. Zone 1 simulations include hands-on instruction of foundational clinical skills. Zone 2 simulations include acute situational instruction, such as clinical mock codes. Zone 3 simulations involve authentic, native teams of participants and facilitate team and system development.The authors also discuss the translation of debriefing methods from Zone 3 simulations to real patient care settings (Zone 4), and they illustrate how the SimZones approach can enable the development of longitudinal learning systems in both teaching and nonteaching hospitals. The SimZones approach was initially developed in the context of the Boston Children's Hospital Simulator Program, which the authors use to illustrate this innovation in action.

  10. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Structures. Copies are available from the American Society of Civil Engineers, Publications Marketing Department, 1801 Alexander Bell Drive, Reston, VA 20191-4400. E-mail: marketing@asce.org. Telephone: (800) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code...

  11. Current status of coastal zone issues and management in China: a review.

    PubMed

    Cao, Wenzhi; Wong, Ming H

    2007-10-01

    This paper identifies and examines social-economic and environmental issues recently emerged in China's coastal zone. Evaluation of management scheme and progress in perspectives of coordinated legislation, institutional arrangement, public participation, capacity building, and scientific research (mainly coastal planning and functional zoning) in China's coastal zone are made. The Chinese government has made a significant effort in developing legislation for the coastal zone. Jurisdictional and zoning boundaries, and allocating use rights for coastal and marine resources have been established. State Oceanic Administration is the leading agency responsible for China's ocean policymaking and overall management of ocean and coastal affairs. A demonstrated project for integrated coastal management in Xiamen has been implemented, and is characterized as "decentralization" approach in decision-making process. In view of the above, comprehensive coastal management in China is a big challenge, facing with many difficulties. Finally, recommendations are raised for tackling these issues for China's coastal zone management.

  12. Characteristics code for shock initiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Partom, Y.

    1986-10-01

    We developed SHIN, a characteristics code for shock initiation studies. We describe in detail the equations of state, reaction model, rate equations, and numerical difference equations that SHIN incorporates. SHIN uses the previously developed surface burning reaction model which better represents the shock initiation process in TATB, than do bulk reaction models. A large number of computed simulations prove the code is a reliable and efficient tool for shock initiation studies. A parametric study shows the effect on build-up and run distance to detonation of (1) type of boundary condtion, (2) burning velocity curve, (3) shock duration, (4) rise timemore » in ramp loading, (5) initial density (or porosity) of the explosive, (6) initial temperature, and (7) grain size. 29 refs., 65 figs.« less

  13. Simulation of probabilistic wind loads and building analysis

    NASA Technical Reports Server (NTRS)

    Shah, Ashwin R.; Chamis, Christos C.

    1991-01-01

    Probabilistic wind loads likely to occur on a structure during its design life are predicted. Described here is a suitable multifactor interactive equation (MFIE) model and its use in the Composite Load Spectra (CLS) computer program to simulate the wind pressure cumulative distribution functions on four sides of a building. The simulated probabilistic wind pressure load was applied to a building frame, and cumulative distribution functions of sway displacements and reliability against overturning were obtained using NESSUS (Numerical Evaluation of Stochastic Structure Under Stress), a stochastic finite element computer code. The geometry of the building and the properties of building members were also considered as random in the NESSUS analysis. The uncertainties of wind pressure, building geometry, and member section property were qualified in terms of their respective sensitivities on the structural response.

  14. Code manual for CONTAIN 2.0: A computer code for nuclear reactor containment analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murata, K.K.; Williams, D.C.; Griffith, R.O.

    1997-12-01

    The CONTAIN 2.0 computer code is an integrated analysis tool used for predicting the physical conditions, chemical compositions, and distributions of radiological materials inside a containment building following the release of material from the primary system in a light-water reactor accident. It can also predict the source term to the environment. CONTAIN 2.0 is intended to replace the earlier CONTAIN 1.12, which was released in 1991. The purpose of this Code Manual is to provide full documentation of the features and models in CONTAIN 2.0. Besides complete descriptions of the models, this Code Manual provides a complete description of themore » input and output from the code. CONTAIN 2.0 is a highly flexible and modular code that can run problems that are either quite simple or highly complex. An important aspect of CONTAIN is that the interactions among thermal-hydraulic phenomena, aerosol behavior, and fission product behavior are taken into account. The code includes atmospheric models for steam/air thermodynamics, intercell flows, condensation/evaporation on structures and aerosols, aerosol behavior, and gas combustion. It also includes models for reactor cavity phenomena such as core-concrete interactions and coolant pool boiling. Heat conduction in structures, fission product decay and transport, radioactive decay heating, and the thermal-hydraulic and fission product decontamination effects of engineered safety features are also modeled. To the extent possible, the best available models for severe accident phenomena have been incorporated into CONTAIN, but it is intrinsic to the nature of accident analysis that significant uncertainty exists regarding numerous phenomena. In those cases, sensitivity studies can be performed with CONTAIN by means of user-specified input parameters. Thus, the code can be viewed as a tool designed to assist the knowledge reactor safety analyst in evaluating the consequences of specific modeling assumptions.« less

  15. Implementing nationally determined contributions: building energy policies in India’s mitigation strategy

    NASA Astrophysics Data System (ADS)

    Yu, Sha; Evans, Meredydd; Kyle, Page; Vu, Linh; Tan, Qing; Gupta, Ashu; Patel, Pralit

    2018-03-01

    The Nationally Determined Contributions are allowing countries to examine options for reducing emissions through a range of domestic policies. India, like many developing countries, has committed to reducing emissions through specific policies, including building energy codes. Here we assess the potential of these sectoral policies to help in achieving mitigation targets. Collectively, it is critically important to see the potential impact of such policies across developing countries in meeting national and global emission goals. Buildings accounted for around one third of global final energy use in 2010, and building energy consumption is expected to increase as income grows in developing countries. Using the Global Change Assessment Model, this study finds that implementing a range of energy efficiency policies robustly can reduce total Indian building energy use by 22% and lower total Indian carbon dioxide emissions by 9% in 2050 compared to the business-as-usual scenario. Among various policies, energy codes for new buildings can result in the most significant savings. For all building energy policies, well-coordinated, consistent implementation is critical, which requires coordination across different departments and agencies, improving capacity of stakeholders, and developing appropriate institutions to facilitate policy implementation.

  16. A global strategy for road building.

    PubMed

    Laurance, William F; Clements, Gopalasamy Reuben; Sloan, Sean; O'Connell, Christine S; Mueller, Nathan D; Goosem, Miriam; Venter, Oscar; Edwards, David P; Phalan, Ben; Balmford, Andrew; Van Der Ree, Rodney; Arrea, Irene Burgues

    2014-09-11

    The number and extent of roads will expand dramatically this century. Globally, at least 25 million kilometres of new roads are anticipated by 2050; a 60% increase in the total length of roads over that in 2010. Nine-tenths of all road construction is expected to occur in developing nations, including many regions that sustain exceptional biodiversity and vital ecosystem services. Roads penetrating into wilderness or frontier areas are a major proximate driver of habitat loss and fragmentation, wildfires, overhunting and other environmental degradation, often with irreversible impacts on ecosystems. Unfortunately, much road proliferation is chaotic or poorly planned, and the rate of expansion is so great that it often overwhelms the capacity of environmental planners and managers. Here we present a global scheme for prioritizing road building. This large-scale zoning plan seeks to limit the environmental costs of road expansion while maximizing its benefits for human development, by helping to increase agricultural production, which is an urgent priority given that global food demand could double by mid-century. Our analysis identifies areas with high environmental values where future road building should be avoided if possible, areas where strategic road improvements could promote agricultural development with relatively modest environmental costs, and 'conflict areas' where road building could have sizeable benefits for agriculture but with serious environmental damage. Our plan provides a template for proactively zoning and prioritizing roads during the most explosive era of road expansion in human history.

  17. U-PLANT GEOGRAPHIC ZONE CLEANUP PROTOTYPE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ROMINE, L.D.

    2006-02-01

    The U Plant geographic zone (UPZ) occupies 0.83 square kilometers on the Hanford Site Central Plateau (200 Area). It encompasses the U Plant canyon (221-U Facility), ancillary facilities that supported the canyon, soil waste sites, and underground pipelines. The UPZ cleanup initiative coordinates the cleanup of the major facilities, ancillary facilities, waste sites, and contaminated pipelines (collectively identified as ''cleanup items'') within the geographic zone. The UPZ was selected as a geographic cleanup zone prototype for resolving regulatory, technical, and stakeholder issues and demonstrating cleanup methods for several reasons: most of the area is inactive, sufficient characterization information is availablemore » to support decisions, cleanup of the high-risk waste sites will help protect the groundwater, and the zone contains a representative cross-section of the types of cleanup actions that will be required in other geographic zones. The UPZ cleanup demonstrates the first of 22 integrated zone cleanup actions on the Hanford Site Central Plateau to address threats to groundwater, the environment, and human health. The UPZ contains more than 100 individual cleanup items. Cleanup actions in the zone will be undertaken using multiple regulatory processes and decision documents. Cleanup actions will include building demolition, waste site and pipeline excavation, and the construction of multiple, large engineered barriers. In some cases, different cleanup actions may be taken at item locations that are immediately adjacent to each other. The cleanup planning and field activities for each cleanup item must be undertaken in a coordinated and cohesive manner to ensure effective execution of the UPZ cleanup initiative. The UPZ zone cleanup implementation plan (ZCIP) was developed to address the need for a fundamental integration tool for UPZ cleanup. As UPZ cleanup planning and implementation moves forward, the ZCIP is intended to be a living document that

  18. National Combustion Code Validated Against Lean Direct Injection Flow Field Data

    NASA Technical Reports Server (NTRS)

    Iannetti, Anthony C.

    2003-01-01

    Most combustion processes have, in some way or another, a recirculating flow field. This recirculation stabilizes the reaction zone, or flame, but an unnecessarily large recirculation zone can result in high nitrogen oxide (NOx) values for combustion systems. The size of this recirculation zone is crucial to the performance of state-of-the-art, low-emissions hardware. If this is a large-scale combustion process, the flow field will probably be turbulent and, therefore, three-dimensional. This research dealt primarily with flow fields resulting from lean direct injection (LDI) concepts, as described in Research & Technology 2001. LDI is a concept that depends heavily on the design of the swirler. The LDI concept has the potential to reduce NOx values from 50 to 70 percent of current values, with good flame stability characteristics. It is cost effective and (hopefully) beneficial to do most of the design work for an LDI swirler using computer-aided design (CAD) and computer-aided engineering (CAE) tools. Computational fluid dynamics (CFD) codes are CAE tools that can calculate three-dimensional flows in complex geometries. However, CFD codes are only beginning to correctly calculate the flow fields for complex devices, and the related combustion models usually remove a large portion of the flow physics.

  19. Innovation Zones: Creating Policy Flexibility for Personalized Learning. Issue Brief

    ERIC Educational Resources Information Center

    Patrick, Susan; Gentz, Susan

    2016-01-01

    There is a new state education policy concept termed either innovation zones or districts of innovation. State education agencies interested in shifting their role from enforcing compliance to one of supporting innovation and building capacity in districts are working to spur new innovative instructional models and create space for…

  20. Becoming Inclusive: A Code of Conduct for Inclusion and Diversity.

    PubMed

    Schmidt, Bonnie J; MacWilliams, Brent R; Neal-Boylan, Leslie

    There are increasing concerns about exclusionary behaviors and lack of diversity in the nursing profession. Exclusionary behaviors, which may include incivility, bullying, and workplace violence, discriminate and isolate individuals and groups who are different, whereas inclusive behaviors encourage diversity. To address inclusion and diversity in nursing, this article offers a code of conduct. This code of conduct builds on existing nursing codes of ethics and applies to nursing students and nurses in both educational and practice settings. Inclusive behaviors that are demonstrated in nurses' relationships with patients, colleagues, the profession, and society are described. This code of conduct provides a basis for measureable change, empowerment, and unification of the profession. Recommendations, implications, and a pledge to action are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. 7 CFR 1436.5 - Eligible borrowers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... with any applicable local zoning, land use, and building codes for the applicable farm storage facility... has all peril structural insurance; (10) Demonstrates compliance with the National Environmental...

  2. International Critical Zone Science: Opportunities to Build a Global Understanding of Land-Water Linkages

    NASA Astrophysics Data System (ADS)

    McDowell, W. H.

    2015-12-01

    Critical Zone science examines the structure and properties of the thin veneer that links surface properties to deep geology, at time scales of seconds to millennia. One of the fundamental premises of the US Critical Zone Observatories program is that CZOs should include some measurements made in common at all sites, as these common measurements will enable us to make stronger inferences about how the structure and function of the critical zone interact to drive key processes such as soil formation, stream flow generation, and nutrient export. Recent advances in real-time sensors provide new opportunities to address some fundamental questions about how hillslope soils and streams are linked. Data from the Luquillo Critical Zone Observatory in Puerto Rico, for example, document a previously undescribed transition, or flipping, of stream and soil biogeochemistry in a tropical rain forest. Under typical conditions, soil moisture is high and soil oxygen content is often low, especially at depth. Streams, in contrast, are typically near oxygen saturation. Under severe drought, however, oxygen increases dramatically in soil air and declines to values that are well below saturation in streams. This flipping in redox conditions suggests that despite the strong hydrologic connection between hillslope and stream, gas dynamics and potentially solute dynamics are decoupled along the flow path. The international CZO community has the opportunity to develop a suite of sensor arrays to document soil air, groundwater chemistry, and stream water chemistry. Progress towards realizing the potential of these international networks to develop coherent sensor programs will be addressed based on the current status of sensor deployments in CZO networks in the US, China, and Europe.

  3. No place like home: using seed zones to improve restoration of native grasses in the West

    Treesearch

    Geoff Koch; Brad St. Clair; Vicky Erickson

    2015-01-01

    Seed zones and seed transfer guidelines describe where plants are most likely to thrive. Scientists with the Forest Service and Agricultural Research Service undertook a 9-year project to build empirical seed zones for bluebunch wheatgrass, a foundational native grass throughout the West. The research will help the Forest Service and Bureau of Land Management...

  4. Seismic responses of two adjacent buildings. I. Data and analyses

    USGS Publications Warehouse

    Çelebi, Mehmet

    1993-01-01

    In this two-part paper, responses of two, adjacent, seven-story buildings in Norwalk, California, to the Whittier-Narrows, Calif, earthquake of Oct. 1, 1987 are studied. Building A, instrumented according to code recommendations, and building B, extensively instrumented, are offset by 16.3 m from one another. The data set includes motions from the superstructure of both buildings, from a downhole below the foundation of building B, and from three free-field sites. Part I of the paper includes descriptions of the buildings, site, instrumentation, and analysis of the data of each building. System identification and spectral analysis techniques are employed in part I. Building A has identical first-mode frequencies of 0.65 Hz for both building axes. The strong-motion response characteristics of building A are considerably different than those determined from low-amplitude tests. Building B has fundamental modes at 0.76 Hz and 0.83 Hz in the major and minor axes, respectively. Torsional and diaphragm effects in building B are negligible.

  5. LOFT. Containment and service building (TAN650) basement floor plan. Basement ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOFT. Containment and service building (TAN-650) basement floor plan. Basement airlock, shielded roadway, service areas, connection to control building. Kaiser engineers 6413-11-STEP/LOFT-650-A-1. Date: October 1964. INEEL index code no. 036-650-00-416-122213 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  6. 49 CFR 41.115 - New buildings to be leased for DOT occupancy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... compliance may include the engineer's and architect's authenticated verifications of seismic design codes... design and construction of new buildings to be leased for DOT occupancy or use will ensure that each building is designed and constructed in accord with the seismic design and construction standards set out...

  7. 49 CFR 41.115 - New buildings to be leased for DOT occupancy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... compliance may include the engineer's and architect's authenticated verifications of seismic design codes... design and construction of new buildings to be leased for DOT occupancy or use will ensure that each building is designed and constructed in accord with the seismic design and construction standards set out...

  8. Space-planning and structural solutions of low-rise buildings: Optimal selection methods

    NASA Astrophysics Data System (ADS)

    Gusakova, Natalya; Minaev, Nikolay; Filushina, Kristina; Dobrynina, Olga; Gusakov, Alexander

    2017-11-01

    The present study is devoted to elaboration of methodology used to select appropriately the space-planning and structural solutions in low-rise buildings. Objective of the study is working out the system of criteria influencing the selection of space-planning and structural solutions which are most suitable for low-rise buildings and structures. Application of the defined criteria in practice aim to enhance the efficiency of capital investments, energy and resource saving, create comfortable conditions for the population considering climatic zoning of the construction site. Developments of the project can be applied while implementing investment-construction projects of low-rise housing at different kinds of territories based on the local building materials. The system of criteria influencing the optimal selection of space-planning and structural solutions of low-rise buildings has been developed. Methodological basis has been also elaborated to assess optimal selection of space-planning and structural solutions of low-rise buildings satisfying the requirements of energy-efficiency, comfort and safety, and economical efficiency. Elaborated methodology enables to intensify the processes of low-rise construction development for different types of territories taking into account climatic zoning of the construction site. Stimulation of low-rise construction processes should be based on the system of approaches which are scientifically justified; thus it allows enhancing energy efficiency, comfort, safety and economical effectiveness of low-rise buildings.

  9. Recommendations for the establishment of the seismic code of Haiti

    NASA Astrophysics Data System (ADS)

    Pierristal, G.; Benito, B.; Cervera, J.; Belizaire, D.

    2013-05-01

    Haiti, because of his seismicity associated with plate boundary and several faults that cross the island of Hispaniola (Haiti-Dominican Republic), has been affected in the past by major earthquakes, which have caused loss of life and damage or considerable structural collapses (ex. 1771, 1842), sometimes the destruction of the cities. The recent earthquake of January 12, 2010, was the most destructive earthquake that any country has experienced in modern times, when we measure the number of people killed with respect to the population of a country (Cavallo et al. 2010). It's obvious that the major causes of theses losses are the lack of awareness of the population about the earthquakes, the absence of seismic code and quality control of the building. In this paper, we propose some recommendations for the establishment of the seismic code of Haiti in order to decrease physical and social impacts of earthquakes in the future. First of all, we present a theoretical part of concepts and fundamental elements to establish a seismic code, such as: description of the methodology for seismic hazard's assessment, presentation of the results in terms of acceleration maps for the whole country (in rock sites) and Uniform Hazard Spectrum (UHS) in the cities, and the criteria for soil classification and amplification factors for including site's effects, equivalent forces, etc. Then, we include a practical part where calculations and comparisons of five seismic codes of different countries (Eurocode 8, Spain, Canada, United States and Dominican Republic) are included, in order to have criteria for making the proposals for Haiti. Using the results of Benito et al (presented in this session S10) we compare the UHS in different cities of Haiti with the response spectrum derived from the application of the spectral shapes given by the aforementioned codes. Furthermore, the classification of soils and buildings have been also analyzed and contrasted with local data in order to

  10. Software Build and Delivery Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robey, Robert W.

    2016-07-10

    This presentation deals with the hierarchy of software build and delivery systems. One of the goals is to maximize the success rate of new users and developers when first trying your software. First impressions are important. Early successes are important. This also reduces critical documentation costs. This is a presentation focused on computer science and goes into detail about code documentation.

  11. Effect of phase change material on the heat transfer rate of different building materials

    NASA Astrophysics Data System (ADS)

    Hasan, Mushfiq; Alam, Shahnur; Ahmed, Dewan Hasan

    2017-12-01

    Phase change material (PCM) is widely known as latent heat storage. A comprehensive study is carried out to investigate the effect of PCM on heat transfer rate of building materials. Paraffin is used as PCM along with different conventional building materials to investigate the heat transfer rate from the heated region to the cold region. PCM is placed along with the three different types of building materials like plaster which is well know building material in urban areas and wood and straw which are commonly used in rural areas for roofing as well as wall panel material and investigated the heat transfer rate. An experimental setup was constructed with number of rectangular shape aluminum detachable casing (as cavity) and placed side by side. Series of rectangular cavity filled with convent ional building materials and PCM and these were placed in between two chambers filled with water at different temperature. Building materials and PCM were placed in different cavities with different combinations and investigated the heat transfer rate. The results show that using the PCM along with other building materials can be used to maintain lower temperature at the inner wall and chamber of the cold region. Moreover, the placement or orientation of the building materials and PCM make significant contribution to heat transfer rate from the heated zone to the cold zone.

  12. NSDann2BS, a neutron spectrum unfolding code based on neural networks technology and two bonner spheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ortiz-Rodriguez, J. M.; Reyes Alfaro, A.; Reyes Haro, A.

    In this work a neutron spectrum unfolding code, based on artificial intelligence technology is presented. The code called ''Neutron Spectrometry and Dosimetry with Artificial Neural Networks and two Bonner spheres'', (NSDann2BS), was designed in a graphical user interface under the LabVIEW programming environment. The main features of this code are to use an embedded artificial neural network architecture optimized with the ''Robust design of artificial neural networks methodology'' and to use two Bonner spheres as the only piece of information. In order to build the code here presented, once the net topology was optimized and properly trained, knowledge stored atmore » synaptic weights was extracted and using a graphical framework build on the LabVIEW programming environment, the NSDann2BS code was designed. This code is friendly, intuitive and easy to use for the end user. The code is freely available upon request to authors. To demonstrate the use of the neural net embedded in the NSDann2BS code, the rate counts of {sup 252}Cf, {sup 241}AmBe and {sup 239}PuBe neutron sources measured with a Bonner spheres system.« less

  13. NSDann2BS, a neutron spectrum unfolding code based on neural networks technology and two bonner spheres

    NASA Astrophysics Data System (ADS)

    Ortiz-Rodríguez, J. M.; Reyes Alfaro, A.; Reyes Haro, A.; Solís Sánches, L. O.; Miranda, R. Castañeda; Cervantes Viramontes, J. M.; Vega-Carrillo, H. R.

    2013-07-01

    In this work a neutron spectrum unfolding code, based on artificial intelligence technology is presented. The code called "Neutron Spectrometry and Dosimetry with Artificial Neural Networks and two Bonner spheres", (NSDann2BS), was designed in a graphical user interface under the LabVIEW programming environment. The main features of this code are to use an embedded artificial neural network architecture optimized with the "Robust design of artificial neural networks methodology" and to use two Bonner spheres as the only piece of information. In order to build the code here presented, once the net topology was optimized and properly trained, knowledge stored at synaptic weights was extracted and using a graphical framework build on the LabVIEW programming environment, the NSDann2BS code was designed. This code is friendly, intuitive and easy to use for the end user. The code is freely available upon request to authors. To demonstrate the use of the neural net embedded in the NSDann2BS code, the rate counts of 252Cf, 241AmBe and 239PuBe neutron sources measured with a Bonner spheres system.

  14. Bernstein's "Codes" and the Linguistics of "Deficit"

    ERIC Educational Resources Information Center

    Jones, Peter E.

    2013-01-01

    This paper examines the key linguistic arguments underpinning Basil Bernstein's theory of "elaborated" and "restricted" "codes". Building on a review of selected highlights from the collective critical response to Bernstein, the paper attempts to clarify the relationship of the theory to "deficit" views…

  15. Nuclear Energy Advanced Modeling and Simulation (NEAMS) waste Integrated Performance and Safety Codes (IPSC) : gap analysis for high fidelity and performance assessment code development.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Joon H.; Siegel, Malcolm Dean; Arguello, Jose Guadalupe, Jr.

    2011-03-01

    are needed for repository modeling are severely lacking. In addition, most of existing reactive transport codes were developed for non-radioactive contaminants, and they need to be adapted to account for radionuclide decay and in-growth. The accessibility to the source codes is generally limited. Because the problems of interest for the Waste IPSC are likely to result in relatively large computational models, a compact memory-usage footprint and a fast/robust solution procedure will be needed. A robust massively parallel processing (MPP) capability will also be required to provide reasonable turnaround times on the analyses that will be performed with the code. A performance assessment (PA) calculation for a waste disposal system generally requires a large number (hundreds to thousands) of model simulations to quantify the effect of model parameter uncertainties on the predicted repository performance. A set of codes for a PA calculation must be sufficiently robust and fast in terms of code execution. A PA system as a whole must be able to provide multiple alternative models for a specific set of physical/chemical processes, so that the users can choose various levels of modeling complexity based on their modeling needs. This requires PA codes, preferably, to be highly modularized. Most of the existing codes have difficulties meeting these requirements. Based on the gap analysis results, we have made the following recommendations for the code selection and code development for the NEAMS waste IPSC: (1) build fully coupled high-fidelity THCMBR codes using the existing SIERRA codes (e.g., ARIA and ADAGIO) and platform, (2) use DAKOTA to build an enhanced performance assessment system (EPAS), and build a modular code architecture and key code modules for performance assessments. The key chemical calculation modules will be built by expanding the existing CANTERA capabilities as well as by extracting useful components from other existing codes.« less

  16. The human dimensions of energy use in buildings: A review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Oca, Simona; Hong, Tianzhen; Langevin, Jared

    The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplifiedmore » by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that

  17. The human dimensions of energy use in buildings: A review

    DOE PAGES

    D'Oca, Simona; Hong, Tianzhen; Langevin, Jared

    2017-08-19

    The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplifiedmore » by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that

  18. Modeling of fire smoke movement in multizone garments building using two open source platforms

    NASA Astrophysics Data System (ADS)

    Khandoker, Md. Arifur Rahman; Galib, Musanna; Islam, Adnan; Rahman, Md. Ashiqur

    2017-06-01

    Casualty of garment factory workers from factory fire in Bangladesh is a recurring tragedy. Smoke, which is more fatal than fire itself, often propagates through different pathways from lower to upper floors during building fire. Among the toxic gases produced from a building fire, carbon monoxide (CO) can be deadly, even in small amounts. This paper models the propagation and transportation of fire induced smoke (CO) that resulted from the burning of synthetic polyester fibers using two open source platforms, CONTAM and Fire Dynamics Simulator (FDS). Smoke migration in a generic multistoried garment factory building in Bangladesh is modeled using CONTAM where each floor is compartmentalized by different zones. The elevator and stairway shafts are modeled by phantom zones to simulate contaminant (CO) transport from one floor to upper floors. FDS analysis involves burning of two different stacks of polyester jacket of six feet height and with a maximum heat release rate per unit area of 1500kw/m2 over a storage area 50m2 and 150m2, respectively. The resulting CO generation and removal rates from FDS are used in CONTAM to predict fire-borne CO propagation in different zones of the garment building. Findings of the study exhibit that the contaminant flow rate is a strong function of the position of building geometry, location of initiation of fire, amount of burnt material, presence of AHU and contaminant generation and removal rate of CO from the source location etc. The transport of fire-smoke in the building Hallways, stairways and lifts are also investigated in detail to examine the safe egress of the occupants in case of fire.

  19. Wood products used in the construction of low-rise nonresidential buildings in the United States, 2003

    Treesearch

    David B. McKeever; Craig Adair; Jennifer O' Connor

    2005-01-01

    Low-rise nonresidential building construction is an important market for lumber, structural wood panels, nonstructural wood panels, and engineered wood products in the United States. This report examines low-rise nonresidential buildings of four or fewer stories only, because buildings with five or more stories are normally severely restricted by building code from...

  20. Building America Case Study: Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate, Ithaca, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    "9One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent development, CARB was interested in investigating a hybrid ventilation method that includes the exhaust air from the crawlspace as a portion of an ASHRAE 62.2 compliant whole-house ventilation strategy. This hybrid ventilation method was evaluated through a series of long-term monitoring tests thatmore » observed temperature, humidity, and pressure conditions through the home and crawlspace. Additionally, CARB worked with NREL to perform multi-point tracer gas testing on six separate ventilation strategies - varying portions of 62.2 required flow supplied by the crawlspace fan and an upstairs bathroom fan. The intent of the tracer gas testing was to identify effective Reciprocal Age of Air (RAoA), which is equivalent to the air change rate in well-mixed zones, for each strategy while characterizing localized infiltration rates in several areas of the home.« less

  1. Non-coding glucometers among pediatric patients with diabetes: looking for the target population and an accuracy evaluation of no-coding personal glucometer.

    PubMed

    Fendler, Wojciech; Hogendorf, Anna; Szadkowska, Agnieszka; Młynarski, Wojciech

    2011-01-01

    Self-monitoring of blood glucose (SMBG) is one of the cornerstones of diabetes management. To evaluate the potential for miscoding of a personal glucometer, to define a target population among pediatric patients with diabetes for a non-coding glucometer and the accuracy of the Contour TS non-coding system. Potential for miscoding during self-monitoring of blood glucose was evaluated by means of an anonymous questionnaire, with worst and best case scenarios evaluated depending on the responses pattern. Testing of the Contour TS system was performed according to guidelines set by the national committee for clinical laboratory standards. Estimated frequency of individuals prone to non-coding ranged from 68.21% (95% 60.70- 75.72%) to 7.95% (95%CI 3.86-12.31%) for the worse and best case scenarios respectively. Factors associated with increased likelihood of non-coding were: a smaller number of tests per day, a greater number of individuals involved in testing and self-testing by the patient with diabetes. The Contour TS device showed intra- and inter-assay accuracy -95%, linear association with laboratory measurements (R2=0.99, p <0.0001) and consistent, but small bias of -1.12% (95% Confidence Interval -3.27 to 1.02%). Clarke error grid analysis showed 4% of values within the benign error zone (B) with the other measurements yielding an acceptably accurate result (zone A). The Contour TS system showed sufficient accuracy to be safely used in monitoring of pediatric diabetic patients. Patients from families with a high throughput of test-strips or multiple individuals involved in SMBG using the same meter are candidates for clinical use of such devices due to an increased risk of calibration errors.

  2. 10 CFR 434.506 - Use of the reference building to determine the energy cost budget.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Use of the reference building to determine the energy cost budget. 434.506 Section 434.506 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...

  3. 10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...

  4. Biological Information Transfer Beyond the Genetic Code: The Sugar Code

    NASA Astrophysics Data System (ADS)

    Gabius, H.-J.

    In the era of genetic engineering, cloning, and genome sequencing the focus of research on the genetic code has received an even further accentuation in the public eye. In attempting, however, to understand intra- and intercellular recognition processes comprehensively, the two biochemical dimensions established by nucleic acids and proteins are not sufficient to satisfactorily explain all molecular events in, for example, cell adhesion or routing. The consideration of further code systems is essential to bridge this gap. A third biochemical alphabet forming code words with an information storage capacity second to no other substance class in rather small units (words, sentences) is established by monosaccharides (letters). As hardware oligosaccharides surpass peptides by more than seven orders of magnitude in the theoretical ability to build isomers, when the total of conceivable hexamers is calculated. In addition to the sequence complexity, the use of magnetic resonance spectroscopy and molecular modeling has been instrumental in discovering that even small glycans can often reside in not only one but several distinct low-energy conformations (keys). Intriguingly, conformers can display notably different capacities to fit snugly into the binding site of nonhomologous receptors (locks). This process, experimentally verified for two classes of lectins, is termed "differential conformer selection." It adds potential for shifts of the conformer equilibrium to modulate ligand properties dynamically and reversibly to the well-known changes in sequence (including anomeric positioning and linkage points) and in pattern of substitution, for example, by sulfation. In the intimate interplay with sugar receptors (lectins, enzymes, and antibodies) the message of coding units of the sugar code is deciphered. Their recognition will trigger postbinding signaling and the intended biological response. Knowledge about the driving forces for the molecular rendezvous, i

  5. Wood and Other Materials Used to Construct Nonresidential Buildings in the United States 2011

    Treesearch

    Craig Adair; David B. McKeever; Chris Gaston; Margaret Stewart

    2013-01-01

    The construction of low-rise nonresidential buildings is an important market for lumber, engineered wood products, and structural and nonstructural wood panels in the United States. This report examines low-rise nonresidential buildings of six or fewer stories. Those with more than six stories are normally severely restricted by building codes from being wood framed....

  6. Building a risk-targeted regional seismic hazard model for South-East Asia

    NASA Astrophysics Data System (ADS)

    Woessner, J.; Nyst, M.; Seyhan, E.

    2015-12-01

    The last decade has tragically shown the social and economic vulnerability of countries in South-East Asia to earthquake hazard and risk. While many disaster mitigation programs and initiatives to improve societal earthquake resilience are under way with the focus on saving lives and livelihoods, the risk management sector is challenged to develop appropriate models to cope with the economic consequences and impact on the insurance business. We present the source model and ground motions model components suitable for a South-East Asia earthquake risk model covering Indonesia, Malaysia, the Philippines and Indochine countries. The source model builds upon refined modelling approaches to characterize 1) seismic activity from geologic and geodetic data on crustal faults and 2) along the interface of subduction zones and within the slabs and 3) earthquakes not occurring on mapped fault structures. We elaborate on building a self-consistent rate model for the hazardous crustal fault systems (e.g. Sumatra fault zone, Philippine fault zone) as well as the subduction zones, showcase some characteristics and sensitivities due to existing uncertainties in the rate and hazard space using a well selected suite of ground motion prediction equations. Finally, we analyze the source model by quantifying the contribution by source type (e.g., subduction zone, crustal fault) to typical risk metrics (e.g.,return period losses, average annual loss) and reviewing their relative impact on various lines of businesses.

  7. 77 FR 2453 - Security Zone; 24th Annual North American International Auto Show, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-18

    ... Docket Management Facility (M-30), U.S. Department of Transportation, West Building Ground Floor, Room.... The security zone will encompass an area of the Detroit River beginning at a point of origin on land... shoreline to connect back to the point of origin. Vessels in close proximity to the security zone will be...

  8. Wood products used in the construction of low-rise nonresidential buildings in the United States, 2008

    Treesearch

    David McKeever

    2010-01-01

    Low-rise nonresidential building construction is an important market for lumber, structural wood panels, nonstructural wood panels, and engineered wood products in the United States. This report examines low-rise nonresidential buildings of four or fewer stories only. Buildings with five or more stories are normally severely restricted by building code from being wood...

  9. Hearing the voices of service user researchers in collaborative qualitative data analysis: the case for multiple coding.

    PubMed

    Sweeney, Angela; Greenwood, Kathryn E; Williams, Sally; Wykes, Til; Rose, Diana S

    2013-12-01

    Health research is frequently conducted in multi-disciplinary teams, with these teams increasingly including service user researchers. Whilst it is common for service user researchers to be involved in data collection--most typically interviewing other service users--it is less common for service user researchers to be involved in data analysis and interpretation. This means that a unique and significant perspective on the data is absent. This study aims to use an empirical report of a study on Cognitive Behavioural Therapy for psychosis (CBTp) to demonstrate the value of multiple coding in enabling service users voices to be heard in team-based qualitative data analysis. The CBTp study employed multiple coding to analyse service users' discussions of CBT for psychosis (CBTp) from the perspectives of a service user researcher, clinical researcher and psychology assistant. Multiple coding was selected to enable multiple perspectives to analyse and interpret data, to understand and explore differences and to build multi-disciplinary consensus. Multiple coding enabled the team to understand where our views were commensurate and incommensurate and to discuss and debate differences. Through the process of multiple coding, we were able to build strong consensus about the data from multiple perspectives, including that of the service user researcher. Multiple coding is an important method for understanding and exploring multiple perspectives on data and building team consensus. This can be contrasted with inter-rater reliability which is only appropriate in limited circumstances. We conclude that multiple coding is an appropriate and important means of hearing service users' voices in qualitative data analysis. © 2012 John Wiley & Sons Ltd.

  10. Project Summary. THE RETC CODE FOR QUANTIFYING THE HYDRAULIC FUNCTIONS OF UNSATURATED SOILS

    EPA Science Inventory

    This summary describes the RETC computer code for analyzing the soil water retention and hydraulic conductivity functions of unsaturated soils. These hydraulic properties are key parameters in any quantitative description of water flow into and through the unsaturated zone of soi...

  11. 76 FR 19975 - Proposed Information Collection; Comment Request; Survey of Building and Zoning Permit Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-11

    ... local building permit officials needed for updating the universe of permit-issuing places. The questions... issued. The universe of permit-issuing places is the sampling frame for the Building Permits Survey (BPS...

  12. 50 CFR Table 5 to Part 680 - Crab Size Codes

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 13 2012-10-01 2012-10-01 false Crab Size Codes 5 Table 5 to Part 680 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) SHELLFISH FISHERIES OF THE EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 680, Table 5 Table 5 to Part 680—Crab Size...

  13. 50 CFR Table 5 to Part 680 - Crab Size Codes

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Crab Size Codes 5 Table 5 to Part 680 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) SHELLFISH FISHERIES OF THE EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 680, Table 5 Table 5 to Part 680—Crab Size...

  14. 50 CFR Table 5 to Part 680 - Crab Size Codes

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 11 2011-10-01 2011-10-01 false Crab Size Codes 5 Table 5 to Part 680 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) SHELLFISH FISHERIES OF THE EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 680, Table 5 Table 5 to Part 680—Crab Size...

  15. A benchmark for subduction zone modeling

    NASA Astrophysics Data System (ADS)

    van Keken, P.; King, S.; Peacock, S.

    2003-04-01

    Our understanding of subduction zones hinges critically on the ability to discern its thermal structure and dynamics. Computational modeling has become an essential complementary approach to observational and experimental studies. The accurate modeling of subduction zones is challenging due to the unique geometry, complicated rheological description and influence of fluid and melt formation. The complicated physics causes problems for the accurate numerical solution of the governing equations. As a consequence it is essential for the subduction zone community to be able to evaluate the ability and limitations of various modeling approaches. The participants of a workshop on the modeling of subduction zones, held at the University of Michigan at Ann Arbor, MI, USA in 2002, formulated a number of case studies to be developed into a benchmark similar to previous mantle convection benchmarks (Blankenbach et al., 1989; Busse et al., 1991; Van Keken et al., 1997). Our initial benchmark focuses on the dynamics of the mantle wedge and investigates three different rheologies: constant viscosity, diffusion creep, and dislocation creep. In addition we investigate the ability of codes to accurate model dynamic pressure and advection dominated flows. Proceedings of the workshop and the formulation of the benchmark are available at www.geo.lsa.umich.edu/~keken/subduction02.html We strongly encourage interested research groups to participate in this benchmark. At Nice 2003 we will provide an update and first set of benchmark results. Interested researchers are encouraged to contact one of the authors for further details.

  16. Research Support Facility (RSF): Leadership in Building Performance (Brochure)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This brochure/poster provides information on the features of the Research Support Facility including a detailed illustration of the facility with call outs of energy efficiency and renewable energy technologies. Imagine an office building so energy efficient that its occupants consume only the amount of energy generated by renewable power on the building site. The building, the Research Support Facility (RSF) occupied by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) employees, uses 50% less energy than if it were built to current commercial code and achieves the U.S. Green Building Council's Leadership in Energy and Environmental Design (LEED{reg_sign})more » Platinum rating. With 19% of the primary energy in the U.S. consumed by commercial buildings, the RSF is changing the way commercial office buildings are designed and built.« less

  17. Observing Complex Systems Thinking in the Zone of Proximal Development

    ERIC Educational Resources Information Center

    Danish, Joshua; Saleh, Asmalina; Andrade, Alejandro; Bryan, Branden

    2017-01-01

    Our paper builds on the construct of the zone of proximal development (ZPD) (Vygotsky in Mind in society: the development of higher psychological processes, Harvard University Press, Cambridge, 1978) to analyze the relationship between students' answers and the help they receive as they construct them. We report on a secondary analysis of…

  18. Methodology to build medical ontology from textual resources.

    PubMed

    Baneyx, Audrey; Charlet, Jean; Jaulent, Marie-Christine

    2006-01-01

    In the medical field, it is now established that the maintenance of unambiguous thesauri goes through ontologies. Our research task is to help pneumologists code acts and diagnoses with a software that represents medical knowledge through a domain ontology. In this paper, we describe our general methodology aimed at knowledge engineers in order to build various types of medical ontologies based on terminology extraction from texts. The hypothesis is to apply natural language processing tools to textual patient discharge summaries to develop the resources needed to build an ontology in pneumology. Results indicate that the joint use of distributional analysis and lexico-syntactic patterns performed satisfactorily for building such ontologies.

  19. IET. Tank building (TAN627). Plans, elevation, details. shows position of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    IET. Tank building (TAN-627). Plans, elevation, details. shows position of tanks within building and concrete supports. Ralph M. Parsons 902-4-ANP-627-A&S 420. Date: Fabruary 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0627-00-693-106975 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  20. 158. ARAIII Reactor building (ARA608) Secondary cooling loop and piping ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    158. ARA-III Reactor building (ARA-608) Secondary cooling loop and piping plan. This drawing was selected as a typical example of piping arrangements within reactor building. Aerojet/general 880-area/GCRE-608-P-16. Date: February 1958. INeel index code no. 063-0608-50-013-102641. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  1. 145. ARAIII Control building (ARA607) Sections. Shows highbay section of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    145. ARA-III Control building (ARA-607) Sections. Shows high-bay section of building over crane rail and beam. Indicates materials of exterior siding. Aerojet-general 880-area/GCRE-607-A-11. Date: February 1958. Ineel index code no. 063-0607-00-013-102556. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  2. Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jian; Xie, YuLong; Athalye, Rahul A.

    As required by statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2013 would achieve greater energy efficiency in buildings subject to the code compared to the 2010 edition of the standard. Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2013 in support of its determination . While Standard 90.1 is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether buildingsmore » constructed to the commercial energy efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The goal of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.« less

  3. Intelligent seismic risk mitigation system on structure building

    NASA Astrophysics Data System (ADS)

    Suryanita, R.; Maizir, H.; Yuniorto, E.; Jingga, H.

    2018-01-01

    Indonesia located on the Pacific Ring of Fire, is one of the highest-risk seismic zone in the world. The strong ground motion might cause catastrophic collapse of the building which leads to casualties and property damages. Therefore, it is imperative to properly design the structural response of building against seismic hazard. Seismic-resistant building design process requires structural analysis to be performed to obtain the necessary building responses. However, the structural analysis could be very difficult and time consuming. This study aims to predict the structural response includes displacement, velocity, and acceleration of multi-storey building with the fixed floor plan using Artificial Neural Network (ANN) method based on the 2010 Indonesian seismic hazard map. By varying the building height, soil condition, and seismic location in 47 cities in Indonesia, 6345 data sets were obtained and fed into the ANN model for the learning process. The trained ANN can predict the displacement, velocity, and acceleration responses with up to 96% of predicted rate. The trained ANN architecture and weight factors were later used to build a simple tool in Visual Basic program which possesses the features for prediction of structural response as mentioned previously.

  4. 24 CFR 200.925b - Residential and institutional building code comparison items.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...); (6) Individual unit smoke detectors; (7) Building alarm systems; (8) Highrise criteria; (b) Light and...) Design live loads; (2) Design dead loads; (3) Snow loads; (4) Wind loads. (5) Earthquake loads (in...

  5. 24 CFR 200.925b - Residential and institutional building code comparison items.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...); (6) Individual unit smoke detectors; (7) Building alarm systems; (8) Highrise criteria; (b) Light and...) Design live loads; (2) Design dead loads; (3) Snow loads; (4) Wind loads. (5) Earthquake loads (in...

  6. 24 CFR 200.925b - Residential and institutional building code comparison items.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...); (6) Individual unit smoke detectors; (7) Building alarm systems; (8) Highrise criteria; (b) Light and...) Design live loads; (2) Design dead loads; (3) Snow loads; (4) Wind loads. (5) Earthquake loads (in...

  7. 78 FR 41332 - Fisheries of the Exclusive Economic Zone Off Alaska

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-10

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration 50 CFR Part 679 Fisheries of the Exclusive Economic Zone Off Alaska CFR Correction In Title 50 of the Code of Federal Regulations, Part 660 to End, revised as of October 1, 2012, on page 556, in Sec. 679.5, paragraph (e)(8)(iii...

  8. 78 FR 41332 - Fisheries of the Exclusive Economic Zone Off Alaska

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-10

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration 50 CFR Part 679 Fisheries of the Exclusive Economic Zone Off Alaska CFR Correction 0 In Title 50 of the Code of Federal Regulations, Part 660 to End, revised as of October 1, 2012, on page 561, in Sec. 679.5, the last sentence is...

  9. Strategies for Building Peer Surgical Coaching Relationships.

    PubMed

    Beasley, Heather L; Ghousseini, Hala N; Wiegmann, Douglas A; Brys, Nicole A; Pavuluri Quamme, Sudha R; Greenberg, Caprice C

    2017-04-19

    Peer surgical coaching is a promising approach for continuing professional development. However, scant guidance is available for surgeons seeking to develop peer-coaching skills. Executive coaching research suggests that effective coaches first establish a positive relationship with their coachees by aligning role and process expectations, establishing rapport, and cultivating mutual trust. To identify the strategies used by peer surgical coaches to develop effective peer-coaching relationships with their coachees. Drawing on executive coaching literature, a 3-part framework was developed to examine the strategies peer surgical coaches (n = 8) used to initially cultivate a relationship with their coachees (n = 11). Eleven introductory 1-hour meetings between coaching pairs participating in a statewide surgical coaching program were audiorecorded, transcribed, and coded on the basis of 3 relationship-building components. Once coded, thematic analysis was used to organize coded strategies into thematic categories and subcategories. Data were collected from October 10, 2014, to March 20, 2015. Data analysis took place from May 26, 2015, to July 20, 2016. Strategies and potentially counterproductive activities for building peer-coaching relationships in the surgical context to inform the future training of surgical coaches. Coaches used concrete strategies to align role and process expectations about the coaching process, to establish rapport, and to cultivate mutual trust with their coachees during introductory meetings. Potential coaching pitfalls are identified that could interfere with each of the 3 relationship-building components. Peer-nominated surgical coaches were provided with training on abstract concepts that underlie effective coaching practices in other fields. By identifying the strategies used by peer surgical coaches to operationalize these concepts, empirically based strategies to inform other surgical coaching programs are provided.

  10. Adding kinetics and hydrodynamics to the CHEETAH thermochemical code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fried, L.E., Howard, W.M., Souers, P.C.

    1997-01-15

    In FY96 we released CHEETAH 1.40, which made extensive improvements on the stability and user friendliness of the code. CHEETAH now has over 175 users in government, academia, and industry. Efforts have also been focused on adding new advanced features to CHEETAH 2.0, which is scheduled for release in FY97. We have added a new chemical kinetics capability to CHEETAH. In the past, CHEETAH assumed complete thermodynamic equilibrium and independence of time. The addition of a chemical kinetic framework will allow for modeling of time-dependent phenomena, such as partial combustion and detonation in composite explosives with large reaction zones. Wemore » have implemented a Wood-Kirkwood detonation framework in CHEETAH, which allows for the treatment of nonideal detonations and explosive failure. A second major effort in the project this year has been linking CHEETAH to hydrodynamic codes to yield an improved HE product equation of state. We have linked CHEETAH to 1- and 2-D hydrodynamic codes, and have compared the code to experimental data. 15 refs., 13 figs., 1 tab.« less

  11. Recovery Act: Training Program Development for Commercial Building Equipment Technicians

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leah Glameyer

    The overall goal of this project has been to develop curricula, certification requirements, and accreditation standards for training on energy efficient practices and technologies for commercial building technicians. These training products will advance industry expertise towards net-zero energy commercial building goals and will result in a substantial reduction in energy use. The ultimate objective is to develop a workforce that can bring existing commercial buildings up to their energy performance potential and ensure that new commercial buildings do not fall below their expected optimal level of performance. Commercial building equipment technicians participating in this training program will learn how tomore » best operate commercial buildings to ensure they reach their expected energy performance level. The training is a combination of classroom, online and on-site lessons. The Texas Engineering Extension Service (TEEX) developed curricula using subject matter and adult learning experts to ensure the training meets certification requirements and accreditation standards for training these technicians. The training targets a specific climate zone to meets the needs, specialized expertise, and perspectives of the commercial building equipment technicians in that zone. The combination of efficient operations and advanced design will improve the internal built environment of a commercial building by increasing comfort and safety, while reducing energy use and environmental impact. Properly trained technicians will ensure equipment operates at design specifications. A second impact is a more highly trained workforce that is better equipped to obtain employment. Organizations that contributed to the development of the training program include TEEX and the Texas Engineering Experiment Station (TEES) (both members of The Texas A&M University System). TEES is also a member of the Building Commissioning Association. This report includes a description of the project

  12. 7 CFR 1436.5 - Eligible borrowers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... erodible land and wetlands conservation provisions according to 7 CFR part 12; (8) Demonstrates compliance with any applicable local zoning, land use, and building codes for the applicable farm storage facility...

  13. Drift Reliability Assessment of a Four Storey Frame Residential Building Under Seismic Loading Considering Multiple Factors

    NASA Astrophysics Data System (ADS)

    Sil, Arjun; Longmailai, Thaihamdau

    2017-09-01

    The lateral displacement of Reinforced Concrete (RC) frame building during an earthquake has an important impact on the structural stability and integrity. However, seismic analysis and design of RC building needs more concern due to its complex behavior as the performance of the structure links to the features of the system having many influencing parameters and other inherent uncertainties. The reliability approach takes into account the factors and uncertainty in design influencing the performance or response of the structure in which the safety level or the probability of failure could be ascertained. This present study, aims to assess the reliability of seismic performance of a four storey residential RC building seismically located in Zone-V as per the code provisions given in the Indian Standards IS: 1893-2002. The reliability assessment performed by deriving an explicit expression for maximum roof-lateral displacement as a failure function by regression method. A total of 319, four storey RC buildings were analyzed by linear static method using SAP2000. However, the change in the lateral-roof displacement with the variation of the parameters (column dimension, beam dimension, grade of concrete, floor height and total weight of the structure) was observed. A generalized relation established by regression method which could be used to estimate the expected lateral displacement owing to those selected parameters. A comparison made between the displacements obtained from analysis with that of the equation so formed. However, it shows that the proposed relation could be used directly to determine the expected maximum lateral displacement. The data obtained from the statistical computations was then used to obtain the probability of failure and the reliability.

  14. Fast determination of soil behavior in the capillary zone using simple laboratory tests.

    DOT National Transportation Integrated Search

    2012-12-01

    Frost heave and thaw weakening are typical problems for engineers building in northern regions. These unsaturated-soil behaviors are : caused by water flowing through the capillary zone to a freezing front, where it forms ice lenses. Although suction...

  15. Estimated damage from the Cascadia Subduction Zone tsunami: A model comparisons using fragility curves

    NASA Astrophysics Data System (ADS)

    Wiebe, D. M.; Cox, D. T.; Chen, Y.; Weber, B. A.; Chen, Y.

    2012-12-01

    Building damage from a hypothetical Cascadia Subduction Zone tsunami was estimated using two methods and applied at the community scale. The first method applies proposed guidelines for a new ASCE 7 standard to calculate the flow depth, flow velocity, and momentum flux from a known runup limit and estimate of the total tsunami energy at the shoreline. This procedure is based on a potential energy budget, uses the energy grade line, and accounts for frictional losses. The second method utilized numerical model results from previous studies to determine maximum flow depth, velocity, and momentum flux throughout the inundation zone. The towns of Seaside and Canon Beach, Oregon, were selected for analysis due to the availability of existing data from previously published works. Fragility curves, based on the hydrodynamic features of the tsunami flow (inundation depth, flow velocity, and momentum flux) and proposed design standards from ASCE 7 were used to estimate the probability of damage to structures located within the inundations zone. The analysis proceeded at the parcel level, using tax-lot data to identify construction type (wood, steel, and reinforced-concrete) and age, which was used as a performance measure when applying the fragility curves and design standards. The overall probability of damage to civil buildings was integrated for comparison between the two methods, and also analyzed spatially for damage patterns, which could be controlled by local bathymetric features. The two methods were compared to assess the sensitivity of the results to the uncertainty in the input hydrodynamic conditions and fragility curves, and the potential advantages of each method discussed. On-going work includes coupling the results of building damage and vulnerability to an economic input output model. This model assesses trade between business sectors located inside and outside the induction zone, and is used to measure the impact to the regional economy. Results highlight

  16. Field investigation on severely damaged aseismic buildings in 2014 Ludian earthquake

    NASA Astrophysics Data System (ADS)

    Lin, Xuchuan; Zhang, Haoyu; Chen, Hongfu; Chen, Hao; Lin, Junqi

    2015-03-01

    The 2014 magnitude 6.5 Ludian earthquake caused a death toll of 617, many landslides and tens of thousands of collapsed buildings. A field investigation to evaluate the damage to buildings was carried out immediately after the occurrence of the earthquake. Severely damaged aseismic buildings, which were basically observed in the downtown of Longtoushan Town, were carefully examined one by one with the aim to improve design codes. This paper summarizes the damage observed to the investigated aseismic buildings in both the structural and local levels. A common failure mode was observed that most of the aseismic buildings, such as RC frame structures and confined masonry structures, were similarly destroyed by severe damage or complete collapse of the first story. The related strong ground motion, which was recorded at the nearby station, had a short duration of less than 20 s but a very large PGA up to 1.0 g. The RC frames based on the new design codes still failed to achieve the design target for "strong column, weak beam". Typical local failure details, which were related to the interaction between RC columns and infill walls and between constructional columns and masonry walls, are summarized with preliminary analyses.

  17. A systematic review of post-deployment injury-related mortality among military personnel deployed to conflict zones.

    PubMed

    Knapik, Joseph J; Marin, Roberto E; Grier, Tyson L; Jones, Bruce H

    2009-07-13

    This paper reports on a systematic review of the literature on the post-conflict injury-related mortality of service members who deployed to conflict zones. Literature databases, reference lists of articles, agencies, investigators, and other sources were examined to find studies comparing injury-related mortality of military veterans who had served in conflict zones with that of contemporary veterans who had not served in conflict zones. Injury-related mortality was defined as a cause of death indicated by International Classification of Diseases E-codes E800 to E999 (external causes) or subgroupings within this range of codes. Twenty studies met the review criteria; all involved veterans serving during either the Vietnam or Persian Gulf conflict. Meta-analysis indicated that, compared with non-conflict-zone veterans, injury-related mortality was elevated for veterans serving in Vietnam (summary mortality rate ratio (SMRR) = 1.26, 95% confidence interval (95%CI) = 1.08-1.46) during 9 to 18 years of follow-up. Similarly, injury-related mortality was elevated for veterans serving in the Persian Gulf War (SMRR = 1.26, 95%CI = 1.16-1.37) during 3 to 8 years of follow-up. Much of the excess mortality among conflict-zone veterans was associated with motor vehicle events. The excess mortality decreased over time. Hypotheses to account for the excess mortality in conflict-zone veterans included post-traumatic stress, coping behaviors such as substance abuse, ill-defined diseases and symptoms, lower survivability in injury events due to conflict-zone comorbidities, altered perceptions of risk, and/or selection processes leading to the deployment of individuals who were risk-takers. Further research on the etiology of the excess mortality in conflict-zone veterans is warranted to develop appropriate interventions.

  18. A systematic review of post-deployment injury-related mortality among military personnel deployed to conflict zones

    PubMed Central

    Knapik, Joseph J; Marin, Roberto E; Grier, Tyson L; Jones, Bruce H

    2009-01-01

    Background This paper reports on a systematic review of the literature on the post-conflict injury-related mortality of service members who deployed to conflict zones. Methods Literature databases, reference lists of articles, agencies, investigators, and other sources were examined to find studies comparing injury-related mortality of military veterans who had served in conflict zones with that of contemporary veterans who had not served in conflict zones. Injury-related mortality was defined as a cause of death indicated by International Classification of Diseases E-codes E800 to E999 (external causes) or subgroupings within this range of codes. Results Twenty studies met the review criteria; all involved veterans serving during either the Vietnam or Persian Gulf conflict. Meta-analysis indicated that, compared with non-conflict-zone veterans, injury-related mortality was elevated for veterans serving in Vietnam (summary mortality rate ratio (SMRR) = 1.26, 95% confidence interval (95%CI) = 1.08–1.46) during 9 to 18 years of follow-up. Similarly, injury-related mortality was elevated for veterans serving in the Persian Gulf War (SMRR = 1.26, 95%CI = 1.16–1.37) during 3 to 8 years of follow-up. Much of the excess mortality among conflict-zone veterans was associated with motor vehicle events. The excess mortality decreased over time. Hypotheses to account for the excess mortality in conflict-zone veterans included post-traumatic stress, coping behaviors such as substance abuse, ill-defined diseases and symptoms, lower survivability in injury events due to conflict-zone comorbidities, altered perceptions of risk, and/or selection processes leading to the deployment of individuals who were risk-takers. Conclusion Further research on the etiology of the excess mortality in conflict-zone veterans is warranted to develop appropriate interventions. PMID:19594931

  19. Ducted-Fan Engine Acoustic Predictions using a Navier-Stokes Code

    NASA Technical Reports Server (NTRS)

    Rumsey, C. L.; Biedron, R. T.; Farassat, F.; Spence, P. L.

    1998-01-01

    A Navier-Stokes computer code is used to predict one of the ducted-fan engine acoustic modes that results from rotor-wake/stator-blade interaction. A patched sliding-zone interface is employed to pass information between the moving rotor row and the stationary stator row. The code produces averaged aerodynamic results downstream of the rotor that agree well with a widely used average-passage code. The acoustic mode of interest is generated successfully by the code and is propagated well upstream of the rotor; temporal and spatial numerical resolution are fine enough such that attenuation of the signal is small. Two acoustic codes are used to find the far-field noise. Near-field propagation is computed by using Eversman's wave envelope code, which is based on a finite-element model. Propagation to the far field is accomplished by using the Kirchhoff formula for moving surfaces with the results of the wave envelope code as input data. Comparison of measured and computed far-field noise levels show fair agreement in the range of directivity angles where the peak radiation lobes from the inlet are observed. Although only a single acoustic mode is targeted in this study, the main conclusion is a proof-of-concept: Navier-Stokes codes can be used both to generate and propagate rotor/stator acoustic modes forward through an engine, where the results can be coupled to other far-field noise prediction codes.

  20. Solar energy in buildings: Implications for California energy policy

    NASA Technical Reports Server (NTRS)

    Hirshberg, A. S.; Davis, E. S.

    1977-01-01

    An assessment of the potential of active solar energy systems for buildings in California is summarized. The technology used for solar heating, cooling, and water heating in buildings is discussed. The major California weather zones and the solar energy designs are described, as well as the sizing of solar energy systems and their performance. The cost of solar energy systems is given both at current prices and at prices consistent with optimistic estimates for the cost of collectors. The main institutional barriers to the wide spread use of solar energy are summarized.

  1. Study on Ecological Risk Assessment of Guangxi Coastal Zone Based on 3s Technology

    NASA Astrophysics Data System (ADS)

    Zhong, Z.; Luo, H.; Ling, Z. Y.; Huang, Y.; Ning, W. Y.; Tang, Y. B.; Shao, G. Z.

    2018-05-01

    This paper takes Guangxi coastal zone as the study area, following the standards of land use type, divides the coastal zone of ecological landscape into seven kinds of natural wetland landscape types such as woodland, farmland, grassland, water, urban land and wetlands. Using TM data of 2000-2015 such 15 years, with the CART decision tree algorithm, for analysis the characteristic of types of landscape's remote sensing image and build decision tree rules of landscape classification to extract information classification. Analyzing of the evolution process of the landscape pattern in Guangxi coastal zone in nearly 15 years, we may understand the distribution characteristics and change rules. Combined with the natural disaster data, we use of landscape index and the related risk interference degree and construct ecological risk evaluation model in Guangxi coastal zone for ecological risk assessment results of Guangxi coastal zone.

  2. Deterministic quantum dense coding networks

    NASA Astrophysics Data System (ADS)

    Roy, Saptarshi; Chanda, Titas; Das, Tamoghna; Sen(De), Aditi; Sen, Ujjwal

    2018-07-01

    We consider the scenario of deterministic classical information transmission between multiple senders and a single receiver, when they a priori share a multipartite quantum state - an attempt towards building a deterministic dense coding network. Specifically, we prove that in the case of two or three senders and a single receiver, generalized Greenberger-Horne-Zeilinger (gGHZ) states are not beneficial for sending classical information deterministically beyond the classical limit, except when the shared state is the GHZ state itself. On the other hand, three- and four-qubit generalized W (gW) states with specific parameters as well as the four-qubit Dicke states can provide a quantum advantage of sending the information in deterministic dense coding. Interestingly however, numerical simulations in the three-qubit scenario reveal that the percentage of states from the GHZ-class that are deterministic dense codeable is higher than that of states from the W-class.

  3. Development of Automated Procedures to Generate Reference Building Models for ASHRAE Standard 90.1 and India’s Building Energy Code and Implementation in OpenStudio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Andrew; Haves, Philip; Jegi, Subhash

    This paper describes a software system for automatically generating a reference (baseline) building energy model from the proposed (as-designed) building energy model. This system is built using the OpenStudio Software Development Kit (SDK) and is designed to operate on building energy models in the OpenStudio file format.

  4. Evaluating Different Green School Building Designs for Albania: Indoor Thermal Comfort, Energy Use Analysis with Solar Systems

    NASA Astrophysics Data System (ADS)

    Dalvi, Ambalika Rajendra

    Improving the conditions of schools in many parts of the world is gradually acquiring importance. The Green School movement is an integral part of this effort since it aims at improving indoor environmental conditions. This would in turn, enhance student- learning while minimizing adverse environmental impact through energy efficiency of comfort-related HVAC and lighting systems. This research, which is a part of a larger research project, aims at evaluating different school building designs in Albania in terms of energy use and indoor thermal comfort, and identify energy efficient options of existing schools. We start by identifying three different climate zones in Albania; Coastal (Durres), Hill/Pre-mountainous (Tirana), mountainous (Korca). Next, two prototypical school building designs are identified from the existing stock. Numerous scenarios are then identified for analysis which consists of combinations of climate zone, building type, building orientation, building upgrade levels, presence of renewable energy systems (solar photovoltaic and solar water heater). The existing building layouts, initially outlined in CAD software and then imported into a detailed building energy software program (eQuest) to perform annual simulations for all scenarios. The research also predicted indoor thermal comfort conditions of the various scenarios on the premise that windows could be opened to provide natural ventilation cooling when appropriate. This study also estimated the energy generated from solar photovoltaic systems and solar water heater systems when placed on the available roof area to determine the extent to which they are able to meet the required electric loads (plug and lights) and building heating loads respectively. The results showed that there is adequate indoor comfort without the need for mechanical cooling for the three climate zones, and that only heating is needed during the winter months.

  5. Site-specific seismic ground motion analyses for transportation infrastructure in the New Madrid seismic zone.

    DOT National Transportation Integrated Search

    2012-11-01

    Generic, code-based design procedures cannot account for the anticipated short-period attenuation and long-period amplification of earthquake ground motions in the deep, soft sediments of the Mississippi Embayment within the New Madrid Seismic Zone (...

  6. Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions for Buildings in 2016 and Later

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deru, Michael; Field-Macumber, Kristin

    This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code (IRC) enacted in Section 1331 of the 2005 Energy Policy Act (EPAct) of 2005, noted in Internal Revenue Service (IRS) Notices 2006-52 (IRS 2006), 2008-40 (IRS 2008) and 2012-26 (IRS 2012), and updated by the Protecting Americans from Tax Hikes (PATH) Act of 2015. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning (HVAC); andmore » service hot water (SHW) systems. This document applies to buildings placed in service on or after January 1, 2016.« less

  7. Investigation of the Impact of the Upstream Induction Zone on LIDAR Measurement Accuracy for Wind Turbine Control Applications using Large-Eddy Simulation

    NASA Astrophysics Data System (ADS)

    Simley, Eric; Y Pao, Lucy; Gebraad, Pieter; Churchfield, Matthew

    2014-06-01

    Several sources of error exist in lidar measurements for feedforward control of wind turbines including the ability to detect only radial velocities, spatial averaging, and wind evolution. This paper investigates another potential source of error: the upstream induction zone. The induction zone can directly affect lidar measurements and presents an opportunity for further decorrelation between upstream wind and the wind that interacts with the rotor. The impact of the induction zone is investigated using the combined CFD and aeroelastic code SOWFA. Lidar measurements are simulated upstream of a 5 MW turbine rotor and the true wind disturbances are found using a wind speed estimator and turbine outputs. Lidar performance in the absence of an induction zone is determined by simulating lidar measurements and the turbine response using the aeroelastic code FAST with wind inputs taken far upstream of the original turbine location in the SOWFA wind field. Results indicate that while measurement quality strongly depends on the amount of wind evolution, the induction zone has little effect. However, the optimal lidar preview distance and circular scan radius change slightly due to the presence of the induction zone.

  8. Performance of Buildings in the 2009 Western Sumatra Earthquake

    NASA Astrophysics Data System (ADS)

    Deierlein, G.; Hart, T.; Alexander, N.; Hausler, E.; Henderson, S.; Wood, K.; Cedillos, V.; Wijanto, S.; Cabrera, C.; Rudianto, S.

    2009-12-01

    The M7.6 earthquake of 30 September 2009 in Western Sumatra, Indonesia caused significant damage and collapse to hundreds of buildings and the deaths of 1,117 people. In Padang City, with a population of about 900,000 people, building collapse was the primary cause of deaths and serious injuries (313 deaths and 431 serious injuries). The predominant building construction types in Padang are concrete moment frames with brick infill and masonry bearing wall systems. Concrete frames are common in multistory commercial retail buildings, offices, schools, and hotels; and masonry bearing wall systems are primarily used in low-rise (usually single story) residential and school buildings. In general, buildings that collapsed did not conform to modern seismic engineering practices that are required by the current Indonesian building code and would be expected in regions of moderate to high seismicity. While collapse of multi-story concrete buildings was more prevalent in older buildings (more than 10 years old), there were several newer buildings that collapsed. Primary deficiencies identified in collapsed or severely damaged buildings included: (a) soft or weak stories that failed in either by sidesway mechanisms or shear failures followed by loss of axial capacity of columns, (b) lack of ductile reinforcing bar detailing in concrete beams, columns, and beam-column joints, (c) poor quality concrete and mortar materials and workmanship, (d) vulnerable building configurations and designs with incomplete or deficient load paths, and (e) out-of-plane wall failures in unreinforced (or marginally reinforced) masonry. While these deficiencies may be expected in older buildings, damage and collapse to some modern (or recently rennovated buildings) indicates a lack of enforcement of building code provisions for design and construction quality assurance. Many new buildings whose structural systems were undamaged were closed due to extensive earthquake damage to brick infill walls

  9. Numerical Modelling of Subduction Zones: a New Beginning

    NASA Astrophysics Data System (ADS)

    Ficini, Eleonora; Dal Zilio, Luca; Doglioni, Carlo; Gerya, Taras V.

    2016-04-01

    , if any (e.g., Doglioni et al., 2007; Afonso et al., 2008). Therefore we attempt to generate a different model setup in which are included both a decoupling at the lithosphere base and the "westward" drift of the lithosphere that implies a relative "eastward" mantle flow. The method used for this task is an implementation of I2VIS code, a 2D thermomechanical code incorporating both a characteristics based marker-in-cell method and conservative finite-difference (FD) schemes (Gerya and Yuen, 2003). The implementation involves both the integration of the LVZ and the application of an incoming and outgoing mantle flow through the lateral boundaries of the rectangular box (that represent the basic setup of the models). This new insight in numerical modelling of subduction zones could help to have a more accurate comprehension on what is actually influencing subduction zones dynamics in order to successively explain what are the causes of this fundamental process and what are its implications on plate tectonics dynamics.

  10. LOFT. Containment and service building (TAN650). Section through east/west axis ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LOFT. Containment and service building (TAN-650). Section through east/west axis of building as viewed from the south. Shows basement and grade levels of containment building, connection to control room on west side, air filter vaults, and duct enclosure for air exhaust system. Kaiser engineers 6413-11-STEP/LOFT-650-A-4. Date: October 1964. INEEL index code no. 036-650-00-486-122216 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  11. Early growth of Kohala volcano and formation of long Hawaiian rift zones

    USGS Publications Warehouse

    Lipman, Peter W.; Calvert, Andrew T.

    2011-01-01

    Transitional-composition pillow basalts from the toe of the Hilo Ridge, collected from outcrop by submersible, have yielded the oldest ages known from the Island of Hawaii: 1138 ± 34 to 1159 ± 33 ka. Hilo Ridge has long been interpreted as a submarine rift zone of Mauna Kea, but the new ages validate proposals that it is the distal east rift zone of Kohala, the oldest subaerial volcano on the island. These ages constrain the inception of tholeiitic volcanism at Kohala, provide the first measured duration of tholeiitic shield building (≥870 k.y.) for any Hawaiian volcano, and show that this 125-km-long rift zone developed to near-total length during early growth of Kohala. Long eastern-trending rift zones of Hawaiian volcanoes may follow fractures in oceanic crust activated by arching of the Hawaiian Swell in front of the propagating hotspot.

  12. Pedestrian-oriented zoning is associated with reduced income and poverty disparities in adult active travel to work, United States.

    PubMed

    Chriqui, Jamie F; Leider, Julien; Thrun, Emily; Nicholson, Lisa M; Slater, Sandy J

    2017-02-01

    Active travel to work can provide additional minutes of daily physical activity. While the literature points to the relationship between zoning, equity and socioeconomic status, and physical activity, no study has quantitatively explored these connections. This study examined whether zoning may help to moderate any income and poverty inequities in active travel and taking public transit to work. Research was conducted between May 2012 and June 2015. Zoning data were compiled for 3914 jurisdictions covering 45.45% of the U.S. population located in 471 of the most populous U.S. counties and 2 consolidated cities located in 48 states and the District of Columbia. (Sensitivity analyses also captured unincorporated areas which, with the municipalities, collectively covered ~72% of the U.S. ) Zoning codes were obtained and evaluated to assess the pedestrian-orientation of the zoning codes. Public transit use, active travel to work, median household income, and poverty data were obtained for all study jurisdictions from the 2010-2014 American Community Survey estimates. Associations were examined through multivariate regression models, controlling for community sociodemographics, clustered on county, with robust standard errors. We found that certain pedestrian-oriented zoning provisions (e.g., crosswalks, bike-pedestrian connectivity, street connectivity, bike lanes, bike parking, and more zoning provisions) were associated with reduced income and/or poverty disparities in rates of public transit use and active travel to work. Findings from this study can help to inform cross-sectoral collaborations between the public health, planning, and transportation fields regarding zoning for pedestrian-orientation and active travel. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Estimation of the behavior factor of existing RC-MRF buildings

    NASA Astrophysics Data System (ADS)

    Vona, Marco; Mastroberti, Monica

    2018-01-01

    In recent years, several research groups have studied a new generation of analysis methods for seismic response assessment of existing buildings. Nevertheless, many important developments are still needed in order to define more reliable and effective assessment procedures. Moreover, regarding existing buildings, it should be highlighted that due to the low knowledge level, the linear elastic analysis is the only analysis method allowed. The same codes (such as NTC2008, EC8) consider the linear dynamic analysis with behavior factor as the reference method for the evaluation of seismic demand. This type of analysis is based on a linear-elastic structural model subject to a design spectrum, obtained by reducing the elastic spectrum through a behavior factor. The behavior factor (reduction factor or q factor in some codes) is used to reduce the elastic spectrum ordinate or the forces obtained from a linear analysis in order to take into account the non-linear structural capacities. The behavior factors should be defined based on several parameters that influence the seismic nonlinear capacity, such as mechanical materials characteristics, structural system, irregularity and design procedures. In practical applications, there is still an evident lack of detailed rules and accurate behavior factor values adequate for existing buildings. In this work, some investigations of the seismic capacity of the main existing RC-MRF building types have been carried out. In order to make a correct evaluation of the seismic force demand, actual behavior factor values coherent with force based seismic safety assessment procedure have been proposed and compared with the values reported in the Italian seismic code, NTC08.

  14. CHEETAH: A next generation thermochemical code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fried, L.; Souers, P.

    1994-11-01

    CHEETAH is an effort to bring the TIGER thermochemical code into the 1990s. A wide variety of improvements have been made in Version 1.0. We have improved the robustness and ease of use of TIGER. All of TIGER`s solvers have been replaced by new algorithms. We find that CHEETAH solves a wider variety of problems with no user intervention (e.g. no guesses for the C-J state) than TIGER did. CHEETAH has been made simpler to use than TIGER; typical use of the code occurs with the new standard run command. CHEETAH will make the use of thermochemical codes more attractivemore » to practical explosive formulators. We have also made an extensive effort to improve over the results of TIGER. CHEETAH`s version of the BKW equation of state (BKWC) is able to accurately reproduce energies from cylinder tests; something that other BKW parameter sets have been unable to do. Calculations performed with BKWC execute very quickly; typical run times are under 10 seconds on a workstation. In the future we plan to improve the underlying science in CHEETAH. More accurate equations of state will be used in the gas and the condensed phase. A kinetics capability will be added to the code that will predict reaction zone thickness. Further ease of use features will eventually be added; an automatic formulator that adjusts concentrations to match desired properties is planned.« less

  15. Introduction to the structures and processes of subduction zones

    NASA Astrophysics Data System (ADS)

    Zheng, Yong-Fei; Zhao, Zi-Fu

    2017-09-01

    Subduction zones have been the focus of many studies since the advent of plate tectonics in 1960s. Workings within subduction zones beneath volcanic arcs have been of particular interest because they prime the source of arc magmas. The results from magmatic products have been used to decipher the structures and processes of subduction zones. In doing so, many progresses have been made on modern oceanic subduction zones, but less progresses on ancient oceanic subduction zones. On the other hand, continental subduction zones have been studied since findings of coesite in metamorphic rocks of supracrustal origin in 1980s. It turns out that high-pressure to ultrahigh-pressure metamorphic rocks in collisional orogens provide a direct target to investigate the tectonism of subduction zones, whereas oceanic and continental arc volcanic rocks in accretionary orogens provide an indirect target to investigate the geochemistry of subduction zones. Nevertheless, metamorphic dehydration and partial melting at high-pressure to ultrahigh-pressure conditions are tectonically applicable to subduction zone processes at forearc to subarc depths, and crustal metasomatism is the physicochemical mechanism for geochemical transfer from the slab to the mantle in subduction channels. Taken together, these provide us with an excellent opportunity to find how the metamorphic, metasomatic and magmatic products are a function of the structures and processes in both oceanic and continental subduction zones. Because of the change in the thermal structures of subduction zones, different styles of metamorphism, metasomatism and magmatism are produced at convergent plate margins. In addition, juvenile and ancient crustal rocks have often suffered reworking in episodes independent of either accretionary or collisional orogeny, leading to continental rifting metamorphism and thus rifting orogeny for mountain building in intracontinental settings. This brings complexity to distinguish the syn

  16. Introduction to the structures and processes of subduction zones

    NASA Astrophysics Data System (ADS)

    Zheng, Yong-Fei; Zhao, Zi-Fu

    2017-09-01

    Subduction zones have been the focus of many studies since the advent of plate tectonics in 1960s. Workings within subduction zones beneath volcanic arcs have been of particular interest because they prime the source of arc magmas. The results from magmatic products have been used to decipher the structures and processes of subduction zones. In doing so, many progresses have been made on modern oceanic subduction zones, but less progresses on ancient oceanic subduction zones. On the other hand, continental subduction zones have been studied since findings of coesite in metamorphic rocks of supracrustal origin in 1980s. It turns out that high-pressure to ultrahigh-pressure metamorphic rocks in collisional orogens provide a direct target to investigate the tectonism of subduction zones, whereas oceanic and continental arc volcanic rocks in accretionary orogens provide an indirect target to investigate the geochemistry of subduction zones. Nevertheless, metamorphic dehydration and partial melting at high-pressure to ultrahigh-pressure conditions are tectonically applicable to subduction zone processes at forearc to subarc depths, and crustal metasomatism is the physicochemical mechanism for geochemical transfer from the slab to the mantle in subduction channels. Taken together, these provide us with an excellent opportunity to find how the metamorphic, metasomatic and magmatic products are a function of the structures and processes in both oceanic and continental subduction zones. Because of the change in the thermal structures of subduction zones, different styles of metamorphism, metasomatism and magmatism are produced at convergent plate margins. In addition, juvenile and ancient crustal rocks have often suffered reworking in episodes independent of either accretionary or collisional orogeny, leading to continental rifting metamorphism and thus rifting orogeny for mountain building in intracontinental settings. This brings complexity to distinguish the syn

  17. Gene-Auto: Automatic Software Code Generation for Real-Time Embedded Systems

    NASA Astrophysics Data System (ADS)

    Rugina, A.-E.; Thomas, D.; Olive, X.; Veran, G.

    2008-08-01

    This paper gives an overview of the Gene-Auto ITEA European project, which aims at building a qualified C code generator from mathematical models under Matlab-Simulink and Scilab-Scicos. The project is driven by major European industry partners, active in the real-time embedded systems domains. The Gene- Auto code generator will significantly improve the current development processes in such domains by shortening the time to market and by guaranteeing the quality of the generated code through the use of formal methods. The first version of the Gene-Auto code generator has already been released and has gone thought a validation phase on real-life case studies defined by each project partner. The validation results are taken into account in the implementation of the second version of the code generator. The partners aim at introducing the Gene-Auto results into industrial development by 2010.

  18. Analysis of Design-Build Processes, Best Practices, and Applications to the Department of Defense

    DTIC Science & Technology

    2006-06-01

    NAVFAC design-build processes published in trade journals, books , magazines, internet articles, and DoD policy. In their book , Contract Management...literature review concentrates on recent articles published in books , trade magazines, and on the internet to determine design-build processes and...Keith Molenaar ) Design-build projects under the State of California’s Public Contract Code (Legaltips.org, 2006) requires the owner, for example the

  19. Generating code adapted for interlinking legacy scalar code and extended vector code

    DOEpatents

    Gschwind, Michael K

    2013-06-04

    Mechanisms for intermixing code are provided. Source code is received for compilation using an extended Application Binary Interface (ABI) that extends a legacy ABI and uses a different register configuration than the legacy ABI. First compiled code is generated based on the source code, the first compiled code comprising code for accommodating the difference in register configurations used by the extended ABI and the legacy ABI. The first compiled code and second compiled code are intermixed to generate intermixed code, the second compiled code being compiled code that uses the legacy ABI. The intermixed code comprises at least one call instruction that is one of a call from the first compiled code to the second compiled code or a call from the second compiled code to the first compiled code. The code for accommodating the difference in register configurations is associated with the at least one call instruction.

  20. MELCOR computer code manuals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Summers, R.M.; Cole, R.K. Jr.; Smith, R.C.

    1995-03-01

    MELCOR is a fully integrated, engineering-level computer code that models the progression of severe accidents in light water reactor nuclear power plants. MELCOR is being developed at Sandia National Laboratories for the U.S. Nuclear Regulatory Commission as a second-generation plant risk assessment tool and the successor to the Source Term Code Package. A broad spectrum of severe accident phenomena in both boiling and pressurized water reactors is treated in MELCOR in a unified framework. These include: thermal-hydraulic response in the reactor coolant system, reactor cavity, containment, and confinement buildings; core heatup, degradation, and relocation; core-concrete attack; hydrogen production, transport, andmore » combustion; fission product release and transport; and the impact of engineered safety features on thermal-hydraulic and radionuclide behavior. Current uses of MELCOR include estimation of severe accident source terms and their sensitivities and uncertainties in a variety of applications. This publication of the MELCOR computer code manuals corresponds to MELCOR 1.8.3, released to users in August, 1994. Volume 1 contains a primer that describes MELCOR`s phenomenological scope, organization (by package), and documentation. The remainder of Volume 1 contains the MELCOR Users Guides, which provide the input instructions and guidelines for each package. Volume 2 contains the MELCOR Reference Manuals, which describe the phenomenological models that have been implemented in each package.« less