Sample records for zt-40 devices

  1. High-accuracy direct ZT and intrinsic properties measurement of thermoelectric couple devices.

    PubMed

    Kraemer, D; Chen, G

    2014-04-01

    Advances in thermoelectric materials in recent years have led to significant improvements in thermoelectric device performance and thus, give rise to many new potential applications. In order to optimize a thermoelectric device for specific applications and to accurately predict its performance ideally the material's figure of merit ZT as well as the individual intrinsic properties (Seebeck coefficient, electrical resistivity, and thermal conductivity) should be known with high accuracy. For that matter, we developed two experimental methods in which the first directly obtains the ZT and the second directly measures the individual intrinsic leg properties of the same p/n-type thermoelectric couple device. This has the advantage that all material properties are measured in the same sample direction after the thermoelectric legs have been mounted in the final device. Therefore, possible effects from crystal anisotropy and from the device fabrication process are accounted for. The Seebeck coefficients, electrical resistivities, and thermal conductivities are measured with differential methods to minimize measurement uncertainties to below 3%. The thermoelectric couple ZT is directly measured with a differential Harman method which is in excellent agreement with the calculated ZT from the individual leg properties. The errors in both the directly measured and calculated thermoelectric couple ZT are below 5% which is significantly lower than typical uncertainties using commercial methods. Thus, the developed technique is ideal for characterizing assembled couple devices and individual thermoelectric materials and enables accurate device optimization and performance predictions. We demonstrate the methods by measuring a p/n-type thermoelectric couple device assembled from commercial bulk thermoelectric Bi2Te3 elements in the temperature range of 30 °C-150 °C and discuss the performance of the couple thermoelectric generator in terms of its efficiency and materials

  2. Thermoelectric ZT enhanced by asymmetric configuration in single-molecule-magnet junctions

    NASA Astrophysics Data System (ADS)

    Niu, Pengbin; Shi, Yunlong; Sun, Zhu; Nie, Yi-Hang; Luo, Hong-Gang

    2016-02-01

    In mesoscopic devices, many factors like the Coulomb and spin interactions can enhance the thermoelectric figure of merit ZT. Here we use a system consisting of a single-molecule magnet (SMM) connected to two ferromagnetic electrodes to consider the possible enhancement effects of thermoelectric efficiency. By introducing an asymmetric configuration to the transport junction, we find that this configuration can significantly enhance the thermoelectric ZT. The optimized asymmetric thermoelectric ZT is five times that of the ZT with a symmetric configuration or non-magnetic case. Due to this asymmetry, a non-zero charge thermopower at the electron-hole symmetry point is also found. These results demonstrate that the asymmetry of the transport junction helps to enhance thermoelectric efficiency and is useful for fabricating SMM-based thermoelectric devices.

  3. ZT Optimization: An Application Focus

    PubMed Central

    Tuley, Richard; Simpson, Kevin

    2017-01-01

    Significant research has been performed on the challenge of improving thermoelectric materials, with maximum peak figure of merit, ZT, the most common target. We use an approximate thermoelectric material model, matched to real materials, to demonstrate that when an application is known, average ZT is a significantly better optimization target. We quantify this difference with some examples, with one scenario showing that changing the doping to increase peak ZT by 19% can lead to a performance drop of 16%. The importance of average ZT means that the temperature at which the ZT peak occurs should be given similar weight to the value of the peak. An ideal material for an application operates across the maximum peak ZT, otherwise maximum performance occurs when the peak value is reduced in order to improve the peak position. PMID:28772668

  4. Potential impact of ZT = 4 thermoelectric materials on solar thermal energy conversion technologies.

    PubMed

    Xie, Ming; Gruen, Dieter M

    2010-11-18

    State-of-the-art methodologies for the conversion of solar thermal power to electricity are based on conventional electromagnetic induction techniques. If appropriate ZT = 4 thermoelectric materials were available, it is likely that conversion efficiencies of 30-40% could be achieved. The availability of all solid state electricity generation would be a long awaited development in part because of the elimination of moving parts. This paper presents a preliminary examination of the potential performance of ZT = 4 power generators in comparison with Stirling engines taking into account specific mass, volume and cost as well as system reliability. High-performance thermoelectrics appear to have distinct advantages over magnetic induction technologies.

  5. Phase I study on the pharmacokinetics and tolerance of ZT-1, a prodrug of huperzine A, for the treatment of Alzheimer's disease

    PubMed Central

    Jia, Jing-ying; Zhao, Qian-hua; Liu, Yun; Gui, Yu-zhou; Liu, Gang-yi; Zhu, Da-yuan; Yu, Chen; Hong, Zhen

    2013-01-01

    Aim: Huperzine A isolated from the Chinese herb Huperzia serrata (Thunb) Trev is a novel reversible and selective AChE inhibitor. The aim of this study was to evaluate the pharmacokinetics and tolerance of single and multiple doses of ZT-1, a novel analogue of huperzine A, in healthy Chinese subjects. Methods: This was a double-blinded, placebo-controlled, randomized, single- and multiple-dose study. For the single-dose study, 9 subjects were randomly divided into 3 groups receiving ZT-1 (0.5, 0.75 or 1 mg, po) according to a Three-way Latin Square Design. For the multiple-dose study, 9 subjects receiving ZT-1 (0.75 mg/d, po) for 8 consecutive days. In the tolerance study, 40 subjects were randomly divided into 5 groups receiving a single dose of ZT-1 (0.5, 0.75, 1, 1.25 or 1.5 mg, po). Plasma and urine concentrations of ZT-1 and Hup A were determined using LC-MS/MS. Pharmacokinetic parameters, including Cmax, AUC0–72 h and AUC0–∞ were calculated. Tolerance assessments were conducted throughout the study. Results: ZT-1 was rapidly absorbed and converted into huperzine A, thus the plasma and urine concentrations of ZT-1 were below the limit of quantification (<0.05 ng/mL). After single-dose administration of ZT-1, the mean tmax of huperzine A was 0.76–0.82 h; the AUC0–72 h and Cmax of huperzine A showed approximately dose-proportional increase over the dose range of 0.5–1 mg. After the multiple-dose administration of ZT-1, a steady-state level of huperzine A was achieved within 2 d. No serious adverse events were observed. Conclusion: ZT-1 is a pro-drug that is rapidly absorbed and converted into huperzine A, and ZT-1 is well tolerated in healthy Chinese volunteers. PMID:23624756

  6. Large thermoelectric figure of merit in graphene layered devices at low temperature

    NASA Astrophysics Data System (ADS)

    Olaya, Daniel; Hurtado-Morales, Mikel; Gómez, Daniel; Alejandro Castañeda-Uribe, Octavio; Juang, Zhen-Yu; Hernández, Yenny

    2018-01-01

    Nanostructured materials have emerged as an alternative to enhance the figure of merit (ZT) of thermoelectric (TE) devices. Graphene exhibits a high electrical conductivity (in-plane) that is necessary for a high ZT; however, this effect is countered by its impressive thermal conductivity. In this work TE layered devices composed of electrochemically exfoliated graphene (EEG) and a phonon blocking material such as poly (3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS), polyaniline (PANI) and gold nanoparticles (AuNPs) at the interface were prepared. The figure of merit, ZT, of each device was measured in the cross-plane direction using the Transient Harman Method (THM) and complemented with AFM-based measurements. The results show remarkable high ZT values (0.81  <  ZT  <  2.45) that are directly related with the topography, surface potential, capacitance gradient and resistance of the devices at the nanoscale.

  7. Temperature and Voltage Offsets in High- ZT Thermoelectrics

    NASA Astrophysics Data System (ADS)

    Levy, George S.

    2018-06-01

    Thermodynamic temperature can take on different meanings. Kinetic temperature is an expectation value and a function of the kinetic energy distribution. Statistical temperature is a parameter of the distribution. Kinetic temperature and statistical temperature, identical in Maxwell-Boltzmann statistics, can differ in other statistics such as those of Fermi-Dirac or Bose-Einstein when a field is present. Thermal equilibrium corresponds to zero statistical temperature gradient, not zero kinetic temperature gradient. Since heat carriers in thermoelectrics are fermions, the difference between these two temperatures may explain voltage and temperature offsets observed during meticulous Seebeck measurements in which the temperature-voltage curve does not go through the origin. In conventional semiconductors, temperature offsets produced by fermionic electrical carriers are not observable because they are shorted by heat phonons in the lattice. In high- ZT materials, however, these offsets have been detected but attributed to faulty laboratory procedures. Additional supporting evidence for spontaneous voltages and temperature gradients includes data collected in epistatic experiments and in the plasma Q-machine. Device fabrication guidelines for testing the hypothesis are suggested including using unipolar junctions stacked in a superlattice, alternating n/ n + and p/ p + junctions, selecting appropriate dimensions, doping, and loading.

  8. Temperature and Voltage Offsets in High-ZT Thermoelectrics

    NASA Astrophysics Data System (ADS)

    Levy, George S.

    2017-10-01

    Thermodynamic temperature can take on different meanings. Kinetic temperature is an expectation value and a function of the kinetic energy distribution. Statistical temperature is a parameter of the distribution. Kinetic temperature and statistical temperature, identical in Maxwell-Boltzmann statistics, can differ in other statistics such as those of Fermi-Dirac or Bose-Einstein when a field is present. Thermal equilibrium corresponds to zero statistical temperature gradient, not zero kinetic temperature gradient. Since heat carriers in thermoelectrics are fermions, the difference between these two temperatures may explain voltage and temperature offsets observed during meticulous Seebeck measurements in which the temperature-voltage curve does not go through the origin. In conventional semiconductors, temperature offsets produced by fermionic electrical carriers are not observable because they are shorted by heat phonons in the lattice. In high-ZT materials, however, these offsets have been detected but attributed to faulty laboratory procedures. Additional supporting evidence for spontaneous voltages and temperature gradients includes data collected in epistatic experiments and in the plasma Q-machine. Device fabrication guidelines for testing the hypothesis are suggested including using unipolar junctions stacked in a superlattice, alternating n/n + and p/p + junctions, selecting appropriate dimensions, doping, and loading.

  9. Graphene-based vdW heterostructure Induced High-efficiency Thermoelectric Devices

    NASA Astrophysics Data System (ADS)

    Liang, Shijun; Ang, Lay Kee

    Thermoelectric material (TE) can convert the heat into electricity to provide green energy source and its performance is characterized by a figure of merit (ZT) parameter. Traditional TE materials only give ZT equal to around 1 at room temperature. But, it is believed that materials with ZT >3 will find wide applications at this low temperature range. Prior studies have implied that the interrelation between electric conductivity and lattice thermal conductivity renders the goal of engineering ZT of bulk materials to reach ZT >3. In this work, we propose a high-efficiency van del Waals (vdW) heterostructure-based thermionic device with graphene electrodes, which is able to harvest wasted heat (around 400K) based on the newly established thermionic emission law of graphene electrodes instead of Seebeck effect, to boost the efficiency of power generation over 10% around room temperature. The efficiency can be above 20% if the Schottky barrier height and cross-plane lattice thermal conductivity of transition metal dichacogenides (TMD) materials can be fine-engineered. As a refrigerator at 260 K, the efficiency is 50% to 80% of Carnot efficiency. Finally, we identify two TMD materials as the ideal candidates of graphene/TMD/graphene devices based on the state-of-art technology.

  10. Efficacy of anti-RON antibody Zt/g4-drug maytansinoid conjugation (Anti-RON ADC) as a novel therapeutics for targeted colorectal cancer therapy.

    PubMed

    Feng, Liang; Yao, Hang-Ping; Wang, Wei; Zhou, Yong-Qing; Zhou, Jianwei; Zhang, Ruiwen; Wang, Ming-Hai

    2014-12-01

    The receptor tyrosine kinase RON is critical in epithelial tumorigenesis and a drug target for cancer therapy. Here, we report the development and therapeutic efficacy of a novel anti-RON antibody Zt/g4-maytansinoid (DM1) conjugates for targeted colorectal cancer (CRC) therapy. Zt/g4 (IgG1a/κ) was conjugated to DM1 via thioether linkage to form Zt/g4-DM1 with a drug-antibody ratio of 4:1. CRC cell lines expressing different levels of RON were tested in vitro to determine Zt/g4-DM1-induced RON endocytosis, cell-cycle arrest, and cytotoxicity. Efficacy of Zt/g4-DM1 in vivo was evaluated in mouse xenograft CRC tumor model. Zt/g4-DM1 rapidly induced RON endocytosis, arrested cell cycle at G2-M phase, reduced cell viability, and caused massive cell death within 72 hours. In mouse xenograft CRC models, Zt/g4-DM1 at a single dose of 20 mg/kg body weight effectively delayed CRC cell-mediated tumor growth up to 20 days. In a multiple dose-ranging study with a five injection regimen, Zt/g4-DM1 inhibited more than 90% tumor growth at doses of 7, 10, and 15 mg/kg body weight. The minimal dose achieving 50% of tumor inhibition was approximately 5.0 mg/kg. The prepared Zt/g4-DM1 is stable at 37°C for up to 30 days. At 60 mg/kg, Zt/g4-DM1 had a moderate toxicity in vivo with an average of 12% reduction in mouse body weight. Zt/g4-DM1 is highly effective in targeted inhibition of CRC cell-derived tumor growth in mouse xenograft models. This work provides the basis for development of humanized Zt/g4-DM1 for RON-targeted CRC therapy in the future. ©2014 American Association for Cancer Research.

  11. 46 CFR 111.40-15 - Overcurrent device.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Overcurrent device. 111.40-15 Section 111.40-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-15 Overcurrent device. The total load on any overcurrent device located in a...

  12. 46 CFR 111.40-15 - Overcurrent device.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Overcurrent device. 111.40-15 Section 111.40-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-15 Overcurrent device. The total load on any overcurrent device located in a...

  13. 46 CFR 111.40-15 - Overcurrent device.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Overcurrent device. 111.40-15 Section 111.40-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-15 Overcurrent device. The total load on any overcurrent device located in a...

  14. 46 CFR 111.40-15 - Overcurrent device.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Overcurrent device. 111.40-15 Section 111.40-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-15 Overcurrent device. The total load on any overcurrent device located in a...

  15. 46 CFR 111.40-15 - Overcurrent device.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Overcurrent device. 111.40-15 Section 111.40-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-15 Overcurrent device. The total load on any overcurrent device located in a...

  16. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  17. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  18. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  19. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  20. 46 CFR 111.40-9 - Locking device.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Locking device. 111.40-9 Section 111.40-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-9 Locking device. The door of each panelboard enclosure that is accessible to...

  1. Thin-film thermoelectric devices with high room-temperature figures of merit.

    PubMed

    Venkatasubramanian, R; Siivola, E; Colpitts, T; O'Quinn, B

    2001-10-11

    Thermoelectric materials are of interest for applications as heat pumps and power generators. The performance of thermoelectric devices is quantified by a figure of merit, ZT, where Z is a measure of a material's thermoelectric properties and T is the absolute temperature. A material with a figure of merit of around unity was first reported over four decades ago, but since then-despite investigation of various approaches-there has been only modest progress in finding materials with enhanced ZT values at room temperature. Here we report thin-film thermoelectric materials that demonstrate a significant enhancement in ZT at 300 K, compared to state-of-the-art bulk Bi2Te3 alloys. This amounts to a maximum observed factor of approximately 2.4 for our p-type Bi2Te3/Sb2Te3 superlattice devices. The enhancement is achieved by controlling the transport of phonons and electrons in the superlattices. Preliminary devices exhibit significant cooling (32 K at around room temperature) and the potential to pump a heat flux of up to 700 W cm-2; the localized cooling and heating occurs some 23,000 times faster than in bulk devices. We anticipate that the combination of performance, power density and speed achieved in these materials will lead to diverse technological applications: for example, in thermochemistry-on-a-chip, DNA microarrays, fibre-optic switches and microelectrothermal systems.

  2. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Device integrity. 610.22 Section 610.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis...

  3. 40 CFR 65.155 - Other control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.155 Other control devices. (a) Other control device equipment and operating requirements. (1... requirements specified in § 65.63(a)(2), or 40 CFR 60.562-1(a)(1)(i)(A) for process vents, or § 65.83(a)(1) for...

  4. High-Performance Three-Stage Cascade Thermoelectric Devices with 20% Efficiency

    NASA Astrophysics Data System (ADS)

    Cook, B. A.; Chan, T. E.; Dezsi, G.; Thomas, P.; Koch, C. C.; Poon, J.; Tritt, T.; Venkatasubramanian, R.

    2015-06-01

    The use of advanced materials has resulted in a significant improvement in thermoelectric device conversion efficiency. Three-stage cascade devices were assembled, consisting of nano-bulk Bi2Te3-based materials on the cold side, PbTe and enhanced TAGS-85 [(AgSbTe2)15(GeTe)85] for the mid-stage, and half-Heusler alloys for the high-temperature top stage. In addition, an area aspect ratio optimization process was applied in order to account for asymmetric thermal transport down the individual n- and p-legs. The n- and p-type chalcogenide alloy materials were prepared by high-energy mechanical ball-milling and/or cryogenic ball-milling of elementary powders, with subsequent consolidation by high-pressure uniaxial hot-pressing. The low-temperature stage materials, nano-bulk Bi2Te3- x Sb x and Bi2Te3- x Se x , exhibit a unique mixture of nanoscale features that leads to an enhanced Seebeck coefficient and reduced lattice thermal conductivity, thereby achieving an average ZT of ~1.26 and ~1.7 in the 27°C to 100°C range for the n-type and p-type materials, respectively. Also, the addition of small amounts of selected rare earth elements has been shown to improve the ZT of TAGS-85 by 25%, compared with conventional or neat TAGS-85, resulting in a ZT = 1.5 at 400°C. The incorporation of these improved materials resulted in a peak device conversion efficiency of ~20% at a temperature difference of 750°C when corrected for radiation heat losses and thermal conduction losses through the lead wires. These high-efficiency results were shown to be reproducible across multiple cascade devices.

  5. 40 CFR 152.500 - Requirements for devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Requirements for devices. 152.500 Section 152.500 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS... and export of devices; (7) FIFRA sec. 25(c)(3), with respect to child-resistant packaging; and (8...

  6. Thermoelectric Power in Bilayer Graphene Device with Ionic Liquid Gating.

    PubMed

    Chien, Yung-Yu; Yuan, Hongtao; Wang, Chang-Ran; Lee, Wei-Li

    2016-02-08

    The quest for materials showing large thermoelectric power has long been one of the important subjects in material science and technology. Such materials have great potential for thermoelectric cooling and also high figure of merit ZT thermoelectric applications. We have fabricated bilayer graphene devices with ionic-liquid gating in order to tune its band gap via application of a perpendicular electric field on a bilayer graphene. By keeping the Fermi level at charge neutral point during the cool-down, we found that the charge puddles effect can be greatly reduced and thus largely improve the transport properties at low T in graphene-based devices using ionic liquid gating. At (Vig, Vbg) = (-1 V, +23 V), a band gap of about 36.6 ± 3 meV forms, and a nearly 40% enhancement of thermoelectric power at T = 120 K is clearly observed. Our works demonstrate the feasibility of band gap tuning in a bilayer graphene using ionic liquid gating. We also remark on the significant influence of the charge puddles effect in ionic-liquid-based devices.

  7. A study on the stability and green synthesis of silver nanoparticles using Ziziphora tenuior (Zt) extract at room temperature.

    PubMed

    Sadeghi, Babak; Gholamhoseinpoor, F

    2015-01-05

    Biomolecules present in plant extracts can be used to reduce metal ions to nanoparticles in a single-step green synthesis process. This biogenic reduction of metal ion to base metal is quite rapid, readily conducted at room temperature and pressure, and easily scaled up. Mediated Synthesis by plant extracts is environmentally benign. The involved reducing agents include the various water soluble plant metabolites (e.g. alkaloids, phenolic compounds, terpenoids) and co-enzymes. Silver (Ag) nanoparticles have the particular focus of plant-based syntheses. Extracts of a diverse range of Ziziphora tenuior (Zt) have been successfully used in making nanoparticles. The aim of this study was to investigate the antioxidant properties of this plant and its ability to synthesize silver nanoparticles. Z.tenuior leaves were used to prepare the aqueous extract for this study. Silver nanoparticles were characterized with different techniques such as UV-vis spectroscopy, Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), Scanning electron microscopy (SEM), and transmission electron microscopy (TEM). Transmission electron microscopy experiments showed that these nanoparticles are spherical and uniformly distributed and its size is from 8 to 40 nm. FT-IR spectroscopy revealed that silver nanoparticles were functionalized with biomolecules that have primary amine group (NH₂), carbonyl group, -OH groups and other stabilizing functional groups. X-ray diffraction pattern showed high purity and face centered cubic structure of silver nanoparticles with size of 38 nm. In addition to plant extracts, live plants can be used for the synthesis. Here were view the methods of making nanoparticles using plant extracts. The scanning electron microscopy (SEM) implies the right of forming silver nanoparticles. The results of TEM, SEM, FT-IR, UV-VIS and XRD confirm that the leaves extract of Zt can synthesis silver nanoparticles. Copyright © 2014 Elsevier B.V. All rights

  8. 40 CFR 65.150 - Absorbers used as control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...

  9. 40 CFR 65.150 - Absorbers used as control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...

  10. 40 CFR 65.150 - Absorbers used as control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...

  11. Monoclonal antibody Zt/g4 targeting RON receptor tyrosine kinase enhances chemosensitivity of bladder cancer cells to Epirubicin by promoting G1/S arrest and apoptosis.

    PubMed

    Chen, Jun-Feng; Yu, Bi-Xia; Yu, Rui; Ma, Liang; Lv, Xiu-Yi; Cheng, Yue; Ma, Qi

    2017-02-01

    Epirubicin (EPI) is one of the most used intravesical chemotherapy agents after transurethral resection to non-muscle invasive bladder tumors (NMIBC) to prevent cancer recurrence and progression. However, even after resection of bladder tumors and intravesical chemotherapy, half of them will recur and progress. RON is a membrane tyrosine kinase receptor usually overexpressed in bladder cancer cells and associated with poor pathological features. This study aims to investigate the effects of anti-RON monoclonal antibody Zt/g4 on the chemosensitivity of bladder cells to EPI. After Zt/g4 treatment, cell cytotoxicity was significantly increased and cell invasion was markedly suppressed in EPI-treated bladder cancer cells. Further investigation indicated that combing Zt/g4 with EPI promoted cell G1/S-phase arrest and apoptosis, which are the potential mechanisms that RON signaling inhibition enhances chemosensitivity of EPI. Thus, combing antibody-based RON targeted therapy enhances the therapeutic effects of intravesical chemotherapy, which provides new strategy for further improvement of NMIBC patient outcomes.

  12. 40 CFR 65.152 - Carbon adsorbers used as control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... control device. If an owner or operator elects to replace a control device on a Group 1 process vent or... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Carbon adsorbers used as control... PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a...

  13. 40 CFR 168.71 - Export pesticide devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Export pesticide devices. 168.71 Section 168.71 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS STATEMENTS OF ENFORCEMENT POLICIES AND INTERPRETATIONS Export Policy and Procedures for Exporting Pesticides...

  14. 40 CFR 168.71 - Export pesticide devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Export pesticide devices. 168.71 Section 168.71 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS STATEMENTS OF ENFORCEMENT POLICIES AND INTERPRETATIONS Export Policy and Procedures for Exporting Pesticides...

  15. 40 CFR 65.151 - Condensers used as control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the design evaluation for storage vessels and low-throughput transfer rack controls. As provided in... control device on a Group 1 process vent or a high-throughput transfer rack with a condenser used as a... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Condensers used as control devices. 65...

  16. 40 CFR 65.151 - Condensers used as control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the design evaluation for storage vessels and low-throughput transfer rack controls. As provided in... control device on a Group 1 process vent or a high-throughput transfer rack with a condenser used as a... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Condensers used as control devices. 65...

  17. 40 CFR 65.151 - Condensers used as control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the design evaluation for storage vessels and low-throughput transfer rack controls. As provided in... control device on a Group 1 process vent or a high-throughput transfer rack with a condenser used as a... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Condensers used as control devices. 65...

  18. 27 CFR 478.40a - Transfer and possession of large capacity ammunition feeding devices.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... large capacity ammunition feeding devices. 478.40a Section 478.40a Alcohol, Tobacco Products, and... AMMUNITION COMMERCE IN FIREARMS AND AMMUNITION Administrative and Miscellaneous Provisions § 478.40a Transfer and possession of large capacity ammunition feeding devices. (a) Prohibition. No person shall transfer...

  19. 27 CFR 478.40a - Transfer and possession of large capacity ammunition feeding devices.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... large capacity ammunition feeding devices. 478.40a Section 478.40a Alcohol, Tobacco Products, and... AMMUNITION COMMERCE IN FIREARMS AND AMMUNITION Administrative and Miscellaneous Provisions § 478.40a Transfer and possession of large capacity ammunition feeding devices. (a) Prohibition. No person shall transfer...

  20. 27 CFR 478.40a - Transfer and possession of large capacity ammunition feeding devices.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... large capacity ammunition feeding devices. 478.40a Section 478.40a Alcohol, Tobacco Products, and... AMMUNITION COMMERCE IN FIREARMS AND AMMUNITION Administrative and Miscellaneous Provisions § 478.40a Transfer and possession of large capacity ammunition feeding devices. (a) Prohibition. No person shall transfer...

  1. 27 CFR 478.40a - Transfer and possession of large capacity ammunition feeding devices.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... large capacity ammunition feeding devices. 478.40a Section 478.40a Alcohol, Tobacco Products, and... AMMUNITION COMMERCE IN FIREARMS AND AMMUNITION Administrative and Miscellaneous Provisions § 478.40a Transfer and possession of large capacity ammunition feeding devices. (a) Prohibition. No person shall transfer...

  2. 27 CFR 478.40a - Transfer and possession of large capacity ammunition feeding devices.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... large capacity ammunition feeding devices. 478.40a Section 478.40a Alcohol, Tobacco Products, and... AMMUNITION COMMERCE IN FIREARMS AND AMMUNITION Administrative and Miscellaneous Provisions § 478.40a Transfer and possession of large capacity ammunition feeding devices. (a) Prohibition. No person shall transfer...

  3. Vertical power MOS transistor as a thermoelectric quasi-nanowire device

    NASA Astrophysics Data System (ADS)

    Roizin, Gregory; Beeri, Ofer; Peretz, Mor Mordechai; Gelbstein, Yaniv

    2016-12-01

    Nano-materials exhibit superior performance over bulk materials in a variety of applications such as direct heat to electricity thermoelectric generators (TEGs) and many more. However, a gap still exists for the integration of these nano-materials into practical applications. This study explores the feasibility of utilizing the advantages of nano-materials' thermo-electric properties, using regular bulk technology. Present-day TEGs are often applied by dedicated thermoelectric materials such as semiconductor alloys (e.g., PbTe, BiTe) whereas the standard semiconductor materials such as the doped silicon have not been widely addressed, with limited exceptions of nanowires. This study attempts to close the gap between the nano-materials' properties and the well-established bulk devices, approached for the first time by exploiting the nano-metric dimensions of the conductive channel in metal-oxide-semiconductor (MOS) structures. A significantly higher electrical current than expected from a bulk silicon device has been experimentally measured as a result of the application of a positive gate voltage and a temperature gradient between the "source" and the "drain" terminals of a commercial NMOS transistor. This finding implies on a "quasi-nanowire" behaviour of the transistor channel, which can be easily controlled by the transistor's gate voltage that is applied. This phenomenon enables a considerable improvement of silicon based TEGs, fabricated by traditional silicon technology. Four times higher ZT values (TEG quality factor) compared to conventional bulk silicon have been observed for an off-the-shelf silicon device. By optimizing the device, it is believed that even higher ZT values can be achieved.

  4. 40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...

  5. 40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...

  6. 40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...

  7. 40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...

  8. 40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...

  9. 40 CFR 265.1088 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 265.1088 Section 265.1088 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Containers § 265.1088 Standards: Closed-vent systems and control devices. (a) This section applies to each...

  10. 40 CFR 264.1087 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 264.1087 Section 264.1087 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....1087 Standards: Closed-vent systems and control devices. (a) This section applies to each closed-vent...

  11. 40 CFR 65.154 - Halogen scrubbers and other halogen reduction devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Halogen scrubbers and other halogen... Routing to a Fuel Gas System or a Process § 65.154 Halogen scrubbers and other halogen reduction devices. (a) Halogen scrubber and other halogen reduction device equipment and operating requirements. (1) An...

  12. New evaluation parameter for wearable thermoelectric generators

    NASA Astrophysics Data System (ADS)

    Wijethunge, Dimuthu; Kim, Woochul

    2018-04-01

    Wearable devices constitute a key application area for thermoelectric devices. However, owing to new constraints in wearable applications, a few conventional device optimization techniques are not appropriate and material evaluation parameters, such as figure of merit (zT) and power factor (PF), tend to be inadequate. We illustrated the incompleteness of zT and PF by performing simulations and considering different thermoelectric materials. The results indicate a weak correlation between device performance and zT and PF. In this study, we propose a new evaluation parameter, zTwearable, which is better suited for wearable applications compared to conventional zT. Owing to size restrictions, gap filler based device optimization is extremely critical in wearable devices. With respect to the occasions in which gap fillers are used, expressions for power, effective thermal conductivity (keff), and optimum load electrical ratio (mopt) are derived. According to the new parameters, the thermal conductivity of the material has become much more critical now. The proposed new evaluation parameter, namely, zTwearable, is extremely useful in the selection of an appropriate thermoelectric material among various candidates prior to the commencement of the actual design process.

  13. 10 CFR 40.25 - General license for use of certain industrial products or devices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false General license for use of certain industrial products or devices. 40.25 Section 40.25 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF SOURCE MATERIAL... person receiving the source material pursuant to such transfer. (e) Any person receiving, acquiring...

  14. 40 CFR 265.1033 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 265.1033 Section 265.1033 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... total carbon working capacity -established as a requirement of § 265.1035(b)(4)(iii)(G), whichever is...

  15. 40 CFR 264.1033 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Closed-vent systems and control devices. 264.1033 Section 264.1033 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... no greater than 20 per-cent of the time required to con-sume the total carbon working cap-a-city...

  16. 40 CFR 264.1087 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of such devices include, but are not limited to, a car-seal or a lock-and-key configuration valve...) A boiler or industrial furnace burning hazardous waste for which the owner or operator has been... requirements of 40 CFR part 266, subpart H; or (E) A boiler or industrial furnace burning hazardous waste for...

  17. 40 CFR 65.111 - Standards: Pressure relief devices in gas/vapor service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Pressure relief devices in gas/vapor service. 65.111 Section 65.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Equipment Leaks § 65.111 Standards...

  18. 40 CFR 265.1088 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... removing the lock. Examples of such devices include, but are not limited to, a car-seal or a lock-and-key... furnace burning hazardous waste for which the owner or operator has been issued a final permit under 40... 266, subpart H; or (E) A boiler or industrial furnace burning hazardous waste for which the owner or...

  19. 40 CFR 141.100 - Criteria and procedures for public water systems using point-of-entry devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Criteria and procedures for public water systems using point-of-entry devices. 141.100 Section 141.100 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Use of Non-Centralized Treatment Devices §...

  20. Development of Heterostructure Materials for Thermoelectric Device Applications

    DTIC Science & Technology

    2005-08-01

    morphology changes as thick QDSLs are grown. Therefore, a correlation of strain and film morphology by x - ray and TEM analysis will be important for...triple axis x - ray analysis and atomic force microscopy (AFM) will be carried out at MIT while thermoelectric measurements will be carried out at...2.5 , zT= S 2CT (1) BI Tt/STo, PbTaSeTe/PbT’ (1) U E QUANTUM DOTS 1* 2.0 SUPERLATTICES SUPsmxrTICS ge. Materials with ZT>>I are of =". x great interest

  1. High Performance Graphene Nano-ribbon Thermoelectric Devices by Incorporation and Dimensional Tuning of Nanopores

    PubMed Central

    Sharafat Hossain, Md; Al-Dirini, Feras; Hossain, Faruque M.; Skafidas, Efstratios

    2015-01-01

    Thermoelectric properties of Graphene nano-ribbons (GNRs) with nanopores (NPs) are explored for a range of pore dimensions in order to achieve a high performance two-dimensional nano-scale thermoelectric device. We reduce thermal conductivity of GNRs by introducing pores in them in order to enhance their thermoelectric performance. The electrical properties (Seebeck coefficient and conductivity) of the device usually degrade with pore inclusion; however, we tune the pore to its optimal dimension in order to minimize this degradation, enhancing the overall thermoelectric performance (high ZT value) of our device. We observe that the side channel width plays an important role to achieve optimal performance while the effect of pore length is less pronounced. This result is consistent with the fact that electronic conduction in GNRs is dominated along its edges. Ballistic transport regime is assumed and a semi-empirical method using Huckel basis set is used to obtain the electrical properties, while the phononic system is characterized by Tersoff empirical potential model. The proposed device structure has potential applications as a nanoscale local cooler and as a thermoelectric power generator. PMID:26083450

  2. High Performance Graphene Nano-ribbon Thermoelectric Devices by Incorporation and Dimensional Tuning of Nanopores.

    PubMed

    Hossain, Md Sharafat; Al-Dirini, Feras; Hossain, Faruque M; Skafidas, Efstratios

    2015-06-17

    Thermoelectric properties of Graphene nano-ribbons (GNRs) with nanopores (NPs) are explored for a range of pore dimensions in order to achieve a high performance two-dimensional nano-scale thermoelectric device. We reduce thermal conductivity of GNRs by introducing pores in them in order to enhance their thermoelectric performance. The electrical properties (Seebeck coefficient and conductivity) of the device usually degrade with pore inclusion; however, we tune the pore to its optimal dimension in order to minimize this degradation, enhancing the overall thermoelectric performance (high ZT value) of our device. We observe that the side channel width plays an important role to achieve optimal performance while the effect of pore length is less pronounced. This result is consistent with the fact that electronic conduction in GNRs is dominated along its edges. Ballistic transport regime is assumed and a semi-empirical method using Huckel basis set is used to obtain the electrical properties, while the phononic system is characterized by Tersoff empirical potential model. The proposed device structure has potential applications as a nanoscale local cooler and as a thermoelectric power generator.

  3. Amino-functionalized sub-40 nm ultrathin Ag/ZnO transparent electrodes for flexible polymer dispersed liquid crystal devices

    NASA Astrophysics Data System (ADS)

    Huang, Jinhua; Lu, Yuehui; Wu, Wenxuan; Li, Jia; Zhang, Xianpeng; Zhu, Chaoting; Yang, Ye; Xu, Feng; Song, Weijie

    2017-11-01

    Various flexible transparent conducting electrodes (FTCEs) have been studied for promising applications in flexible optoelectronic devices, but there are still challenges in achieving higher transparency and conductivity, lower thickness, better mechanical flexibility, and lower preparation temperatures. In this work, we prepared a sub-40 nm Ag(9 nm)/ZnO(30 nm) FTCE at room temperature, where each layer played a relatively independent role in the tailoring of the optoelectronic properties. A continuous and smooth 9-nm Ag thin film was grown on amino-functionalized glass and polyethylene terephthalate (PET) substrates to provide good conductivity. A 30-nm ZnO cladding, as an antireflection layer, further improved the transmittance while hardly affecting the conductivity. The room-temperature grown sub-40 nm Ag/ZnO thin films on PET substrate exhibited a transmittance of 88.6% at 550 nm and a sheet resistance of 7.6 Ω.sq-1, which were superior to those of the commercial ITO. The facile preparation benefits the integration of FTCEs into various flexible optoelectronic devices, where the excellent performance of the sub-40 nm Ag/ZnO FTCEs in a flexible polymer dispersed liquid crystal device was demonstrated. Sub-40 nm Ag/ZnO FTCEs that have the characteristics of simple structure, room-temperature preparation, and easily tailored optoelectronic properties would provide flexible optoelectronic devices with more degrees of freedom.

  4. ProbeZT: Simulation of transport coefficients of molecular electronic junctions under environmental effects using Büttiker's probes

    NASA Astrophysics Data System (ADS)

    Korol, Roman; Kilgour, Michael; Segal, Dvira

    2018-03-01

    We present our in-house quantum transport package, ProbeZT. This program provides linear response coefficients: electrical and electronic thermal conductances, as well as the thermopower of molecular junctions in which electrons interact with the surrounding thermal environment. Calculations are performed based on the Büttiker probe method, which introduces decoherence, energy exchange and dissipation effects phenomenologically using virtual electrode terminals called probes. The program can realize different types of probes, each introducing various environmental effects, including elastic and inelastic scattering of electrons. The molecular system is described by an arbitrary tight-binding Hamiltonian, allowing the study of different geometries beyond simple one-dimensional wires. Applications of the program to study the thermoelectric performance of molecular junctions are illustrated. The program also has a built-in functionality to simulate electron transport in double-stranded DNA molecules based on a tight-binding (ladder) description of the junction.

  5. 40 CFR 1033.535 - Adjusting emission levels to account for infrequently regenerating aftertreatment devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Adjusting emission levels to account for infrequently regenerating aftertreatment devices. 1033.535 Section 1033.535 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM...

  6. 40 CFR 1033.535 - Adjusting emission levels to account for infrequently regenerating aftertreatment devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Adjusting emission levels to account for infrequently regenerating aftertreatment devices. 1033.535 Section 1033.535 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM...

  7. Synthesis and Evaluation of Single Layer, Bilayer, and Multilayer Thermoelectric Thin Films

    DOE R&D Accomplishments Database

    Farmer, J. C.; Barbee, T. W. Jr.; Chapline, G. C. Jr.; Olsen, M. L.; Foreman, R. J.; Summers, L. J.; Dresselhaus, M. S.; Hicks, L. D.

    1995-01-20

    The relative efficiency of a thermoelectric material is measured in terms of a dimensionless figure of merit, ZT. Though all known thermoelectric materials are believed to have ZT{le}1, recent theoretical results predict that thermoelectric devices fabricated as two-dimensional quantum wells (2D QWs) or one-dimensional (ID) quantum wires could have ZT{ge}3. Multilayers with the dimensions of 2D QWs have been synthesized by alternately sputtering thermoelectric and barrier materials onto a moving single-crystal sapphire substrate from dual magnetrons. These materials have been used to test the thermoelectric quantum well concept and gain insight into relevant transport mechanisms. If successful, research could lead to thermoelectric devices that have efficiencies close to that of an ideal Carnot engine. Ultimately, such devices could be used to replace conventional heat engines and mechanical refrigeration systems.

  8. 40 CFR 168.66 - Labeling of pesticide products and devices intended solely for export.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Labeling of pesticide products and... PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS STATEMENTS OF ENFORCEMENT POLICIES AND INTERPRETATIONS Export Policy and Procedures for Exporting Pesticides § 168.66 Labeling of pesticide products and devices...

  9. 40 CFR 168.66 - Labeling of pesticide products and devices intended solely for export.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Labeling of pesticide products and... PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS STATEMENTS OF ENFORCEMENT POLICIES AND INTERPRETATIONS Export Policy and Procedures for Exporting Pesticides § 168.66 Labeling of pesticide products and devices...

  10. Heavily Boron-Doped Silicon Layer for the Fabrication of Nanoscale Thermoelectric Devices

    PubMed Central

    Liu, Yang; Deng, Lingxiao; Zhang, Mingliang; Zhang, Shuyuan; Ma, Jing; Song, Peishuai; Liu, Qing; Ji, An; Yang, Fuhua; Wang, Xiaodong

    2018-01-01

    Heavily boron-doped silicon layers and boron etch-stop techniques have been widely used in the fabrication of microelectromechanical systems (MEMS). This paper provides an introduction to the fabrication process of nanoscale silicon thermoelectric devices. Low-dimensional structures such as silicon nanowire (SiNW) have been considered as a promising alternative for thermoelectric applications in order to achieve a higher thermoelectric figure of merit (ZT) than bulk silicon. Here, heavily boron-doped silicon layers and boron etch-stop processes for the fabrication of suspended SiNWs will be discussed in detail, including boron diffusion, electron beam lithography, inductively coupled plasma (ICP) etching and tetramethylammonium hydroxide (TMAH) etch-stop processes. A 7 μm long nanowire structure with a height of 280 nm and a width of 55 nm was achieved, indicating that the proposed technique is useful for nanoscale fabrication. Furthermore, a SiNW thermoelectric device has also been demonstrated, and its performance shows an obvious reduction in thermal conductivity. PMID:29385759

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filipski, Elisabeth; Berland, Elodie; Univ Paris-Sud, UMR-S0776, Orsay F-91405

    The relevance of P-glycoprotein (P-gp) for irinotecan chronopharmacology was investigated in female B6D2F{sub 1} mice. A three-fold 24 h change in the mRNA expression of Abcb1b was demonstrated in ileum mucosa, with a maximum at Zeitgeber Time (ZT) 15 (p < 0.001). No rhythm was found for abcb1a in ileum mucosa, or for Abcb1a/b in Glasgow osteosarcoma (GOS), a mouse tumor cell line moderately sensitive to irinotecan. Non-tumor-bearing mice received irinotecan (50 mg/kg/day i.v. × 4 days) as a single agent or combined with P-gp inhibitor PSC833 (6.25 mg/kg/day i.p. × 4 days) at ZT3 or ZT15, respectively corresponding tomore » the worst or the best irinotecan tolerability. Endpoints involved survival, body weight change and hematologic toxicity. Antitumor efficacy was studied in GOS-bearing mice receiving irinotecan (25, 30 or 40 mg/kg/day × 4 days) and +/− PSC833 at ZT3 or ZT15, with survival, body weight change, and tumor growth inhibition as endpoints. Non-tumor bearing mice lost an average of 17% or 9% of their body weight according to irinotecan administration at ZT3 or ZT15 respectively (p < 0.001). Dosing at ZT15 rather than ZT3 reduced mean leucopenia (9% vs 53%; p < 0.001). PSC833 aggravated irinotecan lethal toxicity from 4 to ∼ 60%. In tumor-bearing mice, body weight loss was ∼ halved in the mice on irinotecan or irinotecan–PSC833 combination at ZT15 as compared to ZT3 (p < 0.001). PSC833–irinotecan at ZT15 increased tumor inhibition by ∼ 40% as compared to irinotecan only at ZT15. In conclusion, P-gp was an important determinant of the circadian balance between toxicity and efficacy of irinotecan. - Highlights: • Irinotecan chronotolerance and chronoefficacy change as drug was applied with PSC833. • P-glycoprotein is an important player of the toxicity and efficacy of irinotecan. • Timing should be considered if chemotherapy is performed with a MDR1 inhibitor.« less

  12. 40 CFR 142.57 - Bottled water, point-of-use, and point-of-entry devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Bottled water, point-of-use, and point-of-entry devices. 142.57 Section 142.57 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS IMPLEMENTATION Exemptions Issued by the Administrator § 142.57...

  13. 40 CFR 265.1058 - Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and other... and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service...

  14. 40 CFR 264.1058 - Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and other... heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and...

  15. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  16. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  17. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  18. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  19. 40 CFR Table 1 to Subpart Jjjj of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Limits if Using Add-On Control Devices and Capture System If you are required to comply with operating... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...

  20. 40 CFR Table 1 to Subpart Ssss of... - Operating Limits if Using Add-on Control Devices and Capture System

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Using Add-on Control Devices and Capture System If you are required to comply with operating limits by... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...

  1. 40 CFR Table 1 to Subpart Ssss of... - Operating Limits if Using Add-on Control Devices and Capture System

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Using Add-on Control Devices and Capture System If you are required to comply with operating limits by... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...

  2. 40 CFR Table 1 to Subpart Jjjj of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Limits if Using Add-On Control Devices and Capture System If you are required to comply with operating... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...

  3. 40 CFR Table 2 to Subpart Oooo of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... to Subpart OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...

  4. 40 CFR Table 1 to Subpart Jjjj of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...—Operating Limits if Using Add-On Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...

  5. 40 CFR Table 1 to Subpart Ssss of... - Operating Limits if Using Add-on Control Devices and Capture System

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...—Operating Limits if Using Add-on Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...

  6. 40 CFR Table 1 to Subpart Jjjj of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...—Operating Limits if Using Add-On Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...

  7. 40 CFR Table 2 to Subpart Oooo of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... to Subpart OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...

  8. 40 CFR Table 1 to Subpart Ssss of... - Operating Limits if Using Add-on Control Devices and Capture System

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...—Operating Limits if Using Add-on Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...

  9. 40 CFR Table 2 to Subpart Oooo of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to Subpart OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...

  10. 40 CFR Table 2 to Subpart Oooo of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you are required... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...

  11. 40 CFR Table 1 to Subpart Ssss of... - Operating Limits if Using Add-on Control Devices and Capture System

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...—Operating Limits if Using Add-on Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Operating Limits if Using Add-on Control Devices and Capture System 1 Table 1 to Subpart SSSS of Part 63 Protection of Environment...

  12. 40 CFR Table 2 to Subpart Oooo of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... OOOO of Part 63—Operating Limits if Using Add-On Control Devices and Capture System If you are required... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 2 Table 2 to Subpart OOOO of Part 63 Protection of Environment...

  13. 40 CFR Table 1 to Subpart Jjjj of... - Operating Limits if Using Add-On Control Devices and Capture System

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...—Operating Limits if Using Add-On Control Devices and Capture System If you are required to comply with... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Operating Limits if Using Add-On Control Devices and Capture System 1 Table 1 to Subpart JJJJ of Part 63 Protection of Environment...

  14. 40 CFR 63.497 - Back-end process provisions-monitoring provisions for control and recovery devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Back-end process provisions-monitoring... Polymers and Resins § 63.497 Back-end process provisions—monitoring provisions for control and recovery devices. (a) An owner or operator complying with the residual organic HAP limitations in § 63.494(a) using...

  15. 40 CFR 610.40 - General.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false General. 610.40 Section 610.40 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.40 General. Two...

  16. 40 CFR 610.40 - General.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false General. 610.40 Section 610.40 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.40 General. Two...

  17. 40 CFR 610.40 - General.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false General. 610.40 Section 610.40 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.40 General. Two...

  18. 40 CFR 610.40 - General.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false General. 610.40 Section 610.40 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.40 General. Two...

  19. 40 CFR 610.40 - General.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false General. 610.40 Section 610.40 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.40 General. Two...

  20. 40 CFR 60.482-8 - Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and connectors. 60.482-8... Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid...

  1. High-performance shape-engineerable thermoelectric painting

    PubMed Central

    Park, Sung Hoon; Jo, Seungki; Kwon, Beomjin; Kim, Fredrick; Ban, Hyeong Woo; Lee, Ji Eun; Gu, Da Hwi; Lee, Se Hwa; Hwang, Younghun; Kim, Jin-Sang; Hyun, Dow-Bin; Lee, Sukbin; Choi, Kyoung Jin; Jo, Wook; Son, Jae Sung

    2016-01-01

    Output power of thermoelectric generators depends on device engineering minimizing heat loss as well as inherent material properties. However, the device engineering has been largely neglected due to the limited flat or angular shape of devices. Considering that the surface of most heat sources where these planar devices are attached is curved, a considerable amount of heat loss is inevitable. To address this issue, here, we present the shape-engineerable thermoelectric painting, geometrically compatible to surfaces of any shape. We prepared Bi2Te3-based inorganic paints using the molecular Sb2Te3 chalcogenidometalate as a sintering aid for thermoelectric particles, with ZT values of 0.67 for n-type and 1.21 for p-type painted materials that compete the bulk values. Devices directly brush-painted onto curved surfaces produced the high output power of 4.0 mW cm−2. This approach paves the way to designing materials and devices that can be easily transferred to other applications. PMID:27834369

  2. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  3. 40 CFR 60.1815 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false How do I monitor the temperature of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate a device to continuously measure the temperature of the...

  4. 40 CFR 60.1815 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false How do I monitor the temperature of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate a device to continuously measure the temperature of the...

  5. 40 CFR 60.1815 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false How do I monitor the temperature of... I monitor the temperature of flue gases at the inlet of my particulate matter control device? You must install, calibrate, maintain, and operate a device to continuously measure the temperature of the...

  6. High-performance and flexible thermoelectric films by screen printing solution-processed nanoplate crystals.

    PubMed

    Varghese, Tony; Hollar, Courtney; Richardson, Joseph; Kempf, Nicholas; Han, Chao; Gamarachchi, Pasindu; Estrada, David; Mehta, Rutvik J; Zhang, Yanliang

    2016-09-12

    Screen printing allows for direct conversion of thermoelectric nanocrystals into flexible energy harvesters and coolers. However, obtaining flexible thermoelectric materials with high figure of merit ZT through printing is an exacting challenge due to the difficulties to synthesize high-performance thermoelectric inks and the poor density and electrical conductivity of the printed films. Here, we demonstrate high-performance flexible films and devices by screen printing bismuth telluride based nanocrystal inks synthesized using a microwave-stimulated wet-chemical method. Thermoelectric films of several tens of microns thickness were screen printed onto a flexible polyimide substrate followed by cold compaction and sintering. The n-type films demonstrate a peak ZT of 0.43 along with superior flexibility, which is among the highest reported ZT values in flexible thermoelectric materials. A flexible thermoelectric device fabricated using the printed films produces a high power density of 4.1 mW/cm(2) with 60 °C temperature difference between the hot side and cold side. The highly scalable and low cost process to fabricate flexible thermoelectric materials and devices demonstrated here opens up many opportunities to transform thermoelectric energy harvesting and cooling applications.

  7. High-performance and flexible thermoelectric films by screen printing solution-processed nanoplate crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varghese, Tony; Hollar, Courtney; Richardson, Joseph

    Screen printing allows for direct conversion of thermoelectric nanocrystals into flexible energy harvesters and coolers. However, obtaining flexible thermoelectric materials with high figure of merit ZT through printing is an exacting challenge due to the difficulties to synthesize high-performance thermoelectric inks and the poor density and electrical conductivity of the printed films. Here, we demonstrate high-performance flexible films and devices by screen printing bismuth telluride based nanocrystal inks synthesized using a microwave-stimulated wet-chemical method. Thermoelectric films of several tens of microns thickness were screen printed onto a flexible polyimide substrate followed by cold compaction and sintering. The n-type films demonstratemore » a peak ZT of 0.43 along with superior flexibility, which is among the highest reported ZT values in flexible thermoelectric materials. A flexible thermoelectric device fabricated using the printed films produces a high power density of 4.1 mW/cm 2 with 60°C temperature difference between the hot side and cold side. In conclusion, the highly scalable and low cost process to fabricate flexible thermoelectric materials and devices demonstrated here opens up many opportunities to transform thermoelectric energy harvesting and cooling applications.« less

  8. High-performance and flexible thermoelectric films by screen printing solution-processed nanoplate crystals

    DOE PAGES

    Varghese, Tony; Hollar, Courtney; Richardson, Joseph; ...

    2016-09-12

    Screen printing allows for direct conversion of thermoelectric nanocrystals into flexible energy harvesters and coolers. However, obtaining flexible thermoelectric materials with high figure of merit ZT through printing is an exacting challenge due to the difficulties to synthesize high-performance thermoelectric inks and the poor density and electrical conductivity of the printed films. Here, we demonstrate high-performance flexible films and devices by screen printing bismuth telluride based nanocrystal inks synthesized using a microwave-stimulated wet-chemical method. Thermoelectric films of several tens of microns thickness were screen printed onto a flexible polyimide substrate followed by cold compaction and sintering. The n-type films demonstratemore » a peak ZT of 0.43 along with superior flexibility, which is among the highest reported ZT values in flexible thermoelectric materials. A flexible thermoelectric device fabricated using the printed films produces a high power density of 4.1 mW/cm 2 with 60°C temperature difference between the hot side and cold side. In conclusion, the highly scalable and low cost process to fabricate flexible thermoelectric materials and devices demonstrated here opens up many opportunities to transform thermoelectric energy harvesting and cooling applications.« less

  9. High-performance and flexible thermoelectric films by screen printing solution-processed nanoplate crystals

    PubMed Central

    Varghese, Tony; Hollar, Courtney; Richardson, Joseph; Kempf, Nicholas; Han, Chao; Gamarachchi, Pasindu; Estrada, David; Mehta, Rutvik J.; Zhang, Yanliang

    2016-01-01

    Screen printing allows for direct conversion of thermoelectric nanocrystals into flexible energy harvesters and coolers. However, obtaining flexible thermoelectric materials with high figure of merit ZT through printing is an exacting challenge due to the difficulties to synthesize high-performance thermoelectric inks and the poor density and electrical conductivity of the printed films. Here, we demonstrate high-performance flexible films and devices by screen printing bismuth telluride based nanocrystal inks synthesized using a microwave-stimulated wet-chemical method. Thermoelectric films of several tens of microns thickness were screen printed onto a flexible polyimide substrate followed by cold compaction and sintering. The n-type films demonstrate a peak ZT of 0.43 along with superior flexibility, which is among the highest reported ZT values in flexible thermoelectric materials. A flexible thermoelectric device fabricated using the printed films produces a high power density of 4.1 mW/cm2 with 60 °C temperature difference between the hot side and cold side. The highly scalable and low cost process to fabricate flexible thermoelectric materials and devices demonstrated here opens up many opportunities to transform thermoelectric energy harvesting and cooling applications. PMID:27615036

  10. 40 CFR 86.409-78 - Defeat devices, prohibition.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... motorcycle shall be equipped with a defeat device. (b) Defeat device means any element of design which: (1) Senses temperature, vehicle speed, engine RPM, transmission gear, manifold vacuum, or any other parameter...

  11. 40 CFR 86.409-78 - Defeat devices, prohibition.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... motorcycle shall be equipped with a defeat device. (b) Defeat device means any element of design which: (1) Senses temperature, vehicle speed, engine RPM, transmission gear, manifold vacuum, or any other parameter...

  12. 40 CFR 86.409-78 - Defeat devices, prohibition.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... motorcycle shall be equipped with a defeat device. (b) Defeat device means any element of design which: (1) Senses temperature, vehicle speed, engine RPM, transmission gear, manifold vacuum, or any other parameter...

  13. 40 CFR 86.409-78 - Defeat devices, prohibition.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... motorcycle shall be equipped with a defeat device. (b) Defeat device means any element of design which: (1) Senses temperature, vehicle speed, engine RPM, transmission gear, manifold vacuum, or any other parameter...

  14. 40 CFR 86.409-78 - Defeat devices, prohibition.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... motorcycle shall be equipped with a defeat device. (b) Defeat device means any element of design which: (1) Senses temperature, vehicle speed, engine RPM, transmission gear, manifold vacuum, or any other parameter...

  15. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Capture Systems... 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits in the following table...

  16. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Operating Limits for Capture Systems... 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits in the following table...

  17. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Operating Limits for Capture Systems... Subpart IIII of Part 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits...

  18. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Operating Limits for Capture Systems... Subpart IIII of Part 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits...

  19. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Operating Limits for Capture Systems... Subpart IIII of Part 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits...

  20. A pilot study of the efficacy of the POLARGEN® ultrahigh-frequency electric field (40.68 MHz) radiofrequency device in the treatment of facial contouring.

    PubMed

    Kim, Miri; Lim, Jihong; Bae, Jung Min; Park, Hyun Jeong

    2017-11-01

    Various radiofrequency (RF) devices are used to treat skin laxity and face contouring, but few studies have examined ultrahigh-frequency (UHF) electric field (40.68 MHz) RF devices. To evaluate the efficacy and safety of a UHF electric field (40.68 MHz) RF device for skin tightening and face contouring. Ten patients each underwent four sessions of UHF electric field RF device treatment at 2-week intervals. Clinical improvement was evaluated with the patient satisfaction score using a six-point scale, and clinical photographs taken at every visit and 2 months after the RF treatment were assessed. Skin biopsies were obtained from one patient before the first treatment and immediately after the last treatment. Adverse reactions were recorded at every follow-up visit. All patients were women with a mean age of 51.7 ± 7.2 years. The mean satisfaction score was 4.5 ± 0.9 immediately after the last treatment session. Cheek, jawline, and neck enhancement and tightening were apparent in all patients. Side effects were minimal, and there were no burns or major complications. The UHF electric field RF device was effective for skin tightening and facial contouring, without significant adverse reactions.

  1. 40 CFR 63.4965 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... an alternative to Method 3B, the manual method for measuring the oxygen, carbon dioxide, and carbon..., Instruments and Apparatus]” (incorporated by reference, see § 63.14). (4) Use Method 4 of appendix A to 40 CFR... total gaseous organic mass emissions as carbon at the inlet and outlet of the add-on control device...

  2. 40 CFR 63.3545 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... an alternative to Method 3B the manual method for measuring the oxygen, carbon dioxide, and carbon..., Instruments and Apparatus]” (incorporated by reference, see § 63.14). (4) Use Method 4 of appendix A to 40 CFR... total gaseous organic mass emissions as carbon at the inlet and outlet of the add-on control device...

  3. Conjugated-Backbone Effect of Organic Small Molecules for n-Type Thermoelectric Materials with ZT over 0.2.

    PubMed

    Huang, Dazhen; Yao, Huiying; Cui, Yutao; Zou, Ye; Zhang, Fengjiao; Wang, Chao; Shen, Hongguang; Jin, Wenlong; Zhu, Jia; Diao, Ying; Xu, Wei; Di, Chong-An; Zhu, Daoben

    2017-09-20

    Conjugated backbones play a fundamental role in determining the electronic properties of organic semiconductors. On the basis of two solution-processable dihydropyrrolo[3,4-c]pyrrole-1,4-diylidenebis(thieno[3,2-b]thiophene) derivatives with aromatic and quinoid structures, we have carried out a systematic study of the relationship between the conjugated-backbone structure and the thermoelectric properties. In particular, a combination of UV-vis-NIR spectra, photoemission spectroscopy, and doping optimization are utilized to probe the interplay between energy levels, chemical doping, and thermoelectric performance. We found that a moderate change in the conjugated backbone leads to varied doping mechanisms and contributes to dramatic changes in the thermoelectric performance. Notably, the chemically doped A-DCV-DPPTT, a small molecule with aromatic structure, exhibits an electrical conductivity of 5.3 S cm -1 and a high power factor (PF 373 K ) up to 236 μW m -1 K -2 , which is 50 times higher than that of Q-DCM-DPPTT with a quinoid structure. More importantly, the low thermal conductivity enables A-DCV-DPPTT to possess a figure of merit (ZT) of 0.23 ± 0.03, which is the highest value reported to date for thermoelectric materials based on organic small molecules. These results demonstrate that the modulation of the conjugated backbone represents a powerful strategy for tuning the electronic structure and mobility of organic semiconductors toward a maximum thermoelectric performance.

  4. Exact Thermal Transport Properties of Gray-Arsenic using Electon-Phonon Coupling

    NASA Astrophysics Data System (ADS)

    Kang, Seoung-Hun; Kwon, Young-Kyun

    Using various theoretical methods, we investigate the thermoelectric property of gray arsenic. Thermoelectric devices that utilize the Seebeck effect convert heat flow into electrical energy. The conversion efficiency of such a device is determined by its figure of merit or ZT value, which is related to various transport coefficients, such as Seebeck coefficient and the ratio of its electrical conductivity to its thermal counterpart for given temperature. To calculate various transport coefficients and thus the ZT values of gray arsenic, we apply the Boltzmann transport theory to its electronic and phononic structures obtained by density functional theory and density functional perturbation theory together with maximally locallized Wannier functions. During this procedure, we evaluate its relaxation time accurately by explicitly considering electron-phonon coupling. Our result reveals that gray arsenic may be used for a good p-type thermoelectric devices.

  5. Design, fabrication, and delivery of a charge injection device as a stellar tracking device

    NASA Technical Reports Server (NTRS)

    Burke, H. K.; Michon, G. J.; Tomlinson, H. W.; Vogelsong, T. L.; Grafinger, A.; Wilson, R.

    1979-01-01

    Six 128 x 128 CID imagers fabricated on bulk silicon and with thin polysilicon upper-level electrodes were tested in a star tracking mode. Noise and spectral response were measured as a function of temperature over the range of +25 C to -40 C. Noise at 0 C and below was less than 40 rms carriers/pixel for all devices at an effective noise bandwidth of 150 Hz. Quantum yield for all devices averaged 40% from 0.4 to 1.0 microns with no measurable temperature dependence. Extrapolating from these performance parameters to those of a large (400 x 400) array and accounting for design and processing improvements, indicates that the larger array would show a further improvement in noise performance -- on the order of 25 carriers. A preliminary evaluation of the projected performance of the 400 x 400 array and a representative set of star sensor requirements indicates that the CID has excellent potential as a stellar tracking device.

  6. 21 CFR 801.40 - Form of a unique device identifier.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Automatic identification and data capture (AIDC) technology. (b) The UDI must include a device identifier... evident upon visual examination of the label or device package, the label or device package must disclose... label and device packages is deemed to meet all requirements of subpart B of this part. The UPC will...

  7. Foldable Thermoelectric Materials: Improvement of the Thermoelectric Performance of Directly Spun CNT Webs by Individual Control of Electrical and Thermal Conductivity.

    PubMed

    An, Cheng Jin; Kang, Young Hun; Lee, A-Young; Jang, Kwang-Suk; Jeong, Youngjin; Cho, Song Yun

    2016-08-31

    We suggest the fabrication of foldable thermoelectric (TE) materials by embedding conducting polymers into Au-doped CNT webs. The CNT bundles, which are interconnected by a direct spinning method to form 3D networks without interfacial contact resistance, provide both high electrical conductivity and high carrier mobility. The ZT value of the spun CNT web is significantly enhanced through two simple processes. Decorating the porous CNT webs with Au nanoparticles increases the electrical conductivity, resulting in an optimal ZT of 0.163, which represents a more than 2-fold improvement compared to the ZT of pristine CNT webs (0.079). After decoration, polyaniline (PANI) is integrated into the Au-doped CNT webs both to improve the Seebeck coefficient by an energy-filtering effect and to decrease the thermal conductivity by the phonon-scattering effect. This leads to a ZT of 0.203, which is one of the highest ZT values reported for organic TE materials. Moreover, Au-doped CNT/PANI web is ultralightweight, free-standing, thermally stable, and mechanically robust, which makes it a viable candidate for a hybrid TE conversion device for wearable electronics. When a 20 K temperature gradient is applied to the TE module consisting of seven p-n couples, 1.74 μW of power is generated.

  8. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...

  9. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...

  10. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 13 2014-07-01 2014-07-01 false How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...

  11. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 12 2011-07-01 2009-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...

  12. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 13 2012-07-01 2012-07-01 false How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...

  13. 40 CFR 65.115 - Standards: Closed vent systems and control devices; or emissions routed to a fuel gas system or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Closed vent systems and control devices; or emissions routed to a fuel gas system or process. 65.115 Section 65.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Equipment Leaks § 65.115 Standards:...

  14. 40 CFR 63.1034 - Closed vent systems and control devices; or emissions routed to a fuel gas system or process...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Closed vent systems and control devices; or emissions routed to a fuel gas system or process standards. 63.1034 Section 63.1034 Protection... stringent. The 20 parts per million by volume standard is not applicable to the provisions of § 63.1016. (ii...

  15. 40 CFR 63.1034 - Closed vent systems and control devices; or emissions routed to a fuel gas system or process...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Closed vent systems and control devices; or emissions routed to a fuel gas system or process standards. 63.1034 Section 63.1034 Protection... stringent. The 20 parts per million by volume standard is not applicable to the provisions of § 63.1016. (ii...

  16. Can an electronic device with a single cuff be accurate in a wide range of arm size? Validation of the Visomat Comfort 20/40 device for home blood pressure monitoring.

    PubMed

    Stergiou, G S; Tzamouranis, D; Nasothimiou, E G; Protogerou, A D

    2008-11-01

    An appropriate cuff according to the individual's arm circumference is recommended with all blood pressure (BP) monitors. An electronic device for home monitoring has been developed (Visomat Comfort 20/40) that estimates the individual's arm circumference by measuring the cuff filing volume and makes an adjustment of measured BP taking into account the estimated arm circumference. Thus the manufacturer recommends the use of a single cuff for arm circumference 23-43 cm. The device accuracy was assessed using the European Society of Hypertension International Protocol. Simultaneous BP measurements were obtained in 33 adults by two observers (connected mercury sphygmomanometers) four times, sequentially with three measurements taken using the tested device. Absolute device-observer BP differences were classified into < or =5, < or =10 and < or =15 mm Hg zones. For each participant the number of measurements with a difference < or =5 mm Hg was calculated. The device produced 60/89/97 measurements within 5/10/15 mm Hg respectively for systolic BP, and 72/97/98 for diastolic. Twenty-three subjects had at least two of their systolic BP differences < or =5 mm Hg and three had no differences < or =5 mm Hg (for diastolic 27 and 1, respectively). Mean device-observer BP difference (systolic/diastolic) was 3.7 +/- 5.6/-1.5 +/- 4.7 mm Hg (4.7 +/- 4.9/ - 1.7 +/- 4.3 in arm circumference 23-29 cm [39 readings] and 3.1 +/- 5.9/-1.4 +/- 5.0 in arm 30-34 cm [60 readings], P=NS). In conclusion, the device fulfils the International Protocol requirements and can be recommended for clinical use. Interestingly, the device was accurate using a single cuff in a wide range of arm circumference (23-34 cm). This study provides no information about the device accuracy in larger arms.

  17. Analysis of Advanced Thermoelectric Materials and Their Functional Limits

    NASA Technical Reports Server (NTRS)

    Kim, Hyun Jung

    2015-01-01

    The world's demand for energy is increasing dramatically, but the best energy conversion systems operate at approximately 30% efficiency. One way to decrease energy loss is in the recovery of waste heat using thermoelectric (TE) generators. A TE generator is device that generates electricity by exploiting heat flow across a thermal gradient. The efficiency of a TE material for power generation and cooling is determined by the dimensionless Figure of Merit (ZT): ZT = S(exp. 2)sigmaT/?: where S is the Seebeck coefficient, sigma is the electrical conductivity, T is the absolute temperature, and ? is the thermal conductivity. The parameters are not physically independent, but intrinsically coupled since they are a function of the transport properties of electrons. Traditional research on TE materials has focused on synthesizing bulk semiconductor-type materials that have low thermal conductivity and high electrical conductivity affording ZT values of 1. The optimization of the s/? ratio is difficult to achieve using current material formats, as these material constants are complementary. Recent areas of research are focusing on using nanostructural artifacts that introduce specific dislocations and boundary conditions that scatter the phonons. This disrupts the physical link between thermal (phonon) and electrical (electron) transport. The result is that ? is decreased without decreasing s. These material formats give ZT values of up to 2 which represent approximately 18% energy gain from waste heat recovery. The next challenge in developing the next generation of TE materials with superior performance is to tailor the interconnected thermoelectric physical parameters of the material system. In order to approach this problem, the fundamental physics of each parameter S, sigma, and ? need to be physically understood in their context of electron/phonon interaction for the construction of new high ZT thermoelectric devices. Is it possible to overcome the physical limit

  18. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  19. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  20. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  1. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  2. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  3. High thermoelectric properties of (Sb, Bi)2Te3 nanowire arrays by tilt-structure engineering

    NASA Astrophysics Data System (ADS)

    Tan, Ming; Hao, Yanming; Deng, Yuan; Chen, Jingyi

    2018-06-01

    In this paper, we present an innovative tilt-structure design concept for (Sb, Bi)2Te3 nanowire array assembled by high-quality nanowires with well oriented growth, utilizing a simple vacuum thermal evaporation technique. The unusual tilt-structure (Sb, Bi)2Te3 nanowire array with a tilted angle of 45° exhibits a high thermoelectric dimensionless figure-of-merit ZT = 1.72 at room temperature. The relatively high ZT value in contrast to that of previously reported (Sb, Bi)2Te3 materials and the vertical (Sb, Bi)2Te3 nanowire arrays evidently reveals the crucial role of the unique tilt-structure in favorably influencing carrier and phonon transport properties, resulting in a significantly improved ZT value. The transport mechanism of such tilt-structure is proposed and investigated. This method opens a new approach to optimize nano-structure in thin films for next-generation thermoelectric materials and devices.

  4. Can productivity and profitability be enhanced in intensively managed cereal systems while reducing the environmental footprint of production? Assessing sustainable intensification options in the breadbasket of India.

    PubMed

    Kumar, Virender; Jat, Hanuman S; Sharma, Parbodh C; Balwinder-Singh; Gathala, Mahesh K; Malik, Ram K; Kamboj, Baldev R; Yadav, Arvind K; Ladha, Jagdish K; Raman, Anitha; Sharma, D K; McDonald, Andrew

    2018-01-15

    Scenarios 3 and 4 were 15-17% higher, whereas, in Scenario 2, yield was either similar in normal years or higher in warmer years. During the rainy ( kharif ) season, ZT-DSR provided yields similar to or higher than those of PTR in the first three years and lower (11-30%) in Years 4 and 5, a result that provides a note of caution for interpreting technology performance through short-term trials or simply averaging results over several years. The resource use and economic and environmental advantages of DSR were more stable through time, including reductions in irrigation water (22-40%), production cost (11-17%), energy inputs (13-34%), and total GWP (14-32%). The integration of "best practices" in PTR in Scenario 2 resulted in reductions of 24% in irrigation water and 21% in GWP, with a positive impact on yield (0.9 t/ha) and profitability compared to conventional PTR, demonstrating the power of simple management changes to generate improved SI outcomes. When ZT maize was used as a diversification option instead of rice in Scenario 4, reductions in resource use jumped to 82-89% for irrigation water and 49-66% for energy inputs, with 13-40% lower GWP, similar or higher rice equivalent yield, and higher profitability (27-73%) in comparison to the rice-based scenarios. Despite these advantages, maize value chains are not robust in this part of India and public procurement is absent. Results do demonstrate that transformative opportunities exist to break the cycle of stagnating yields and inefficient resource use in the most productive cereal-based cropping systems of South Asia. However, these SI entry points need to be placed in the context of the major drivers of change in the region, including market conditions, risks, and declining labor availability, and matching with the needs and interests of different types of farmers.

  5. VLSI (Very Large Scale Integrated Circuits) Device Reliability Models.

    DTIC Science & Technology

    1984-12-01

    CIRCUIT COMPLEXITY FAILURE RATES FOR... A- 40 MOS SSI/MSI DEVICES IN FAILURE PER 106 HOURS TABLE 5.1.2.5-19: C1 AND C2 CIRCUIT COMPLEXITY FAILURE RATES FOR...A- 40 MOS SSI/MSI DEVICES IN FAILURE PER 106 HOURS TABLE 5.1.2.5-19: Cl AND C2 CIRCUIT COMPLEXITY FAILURE RATES FOR... A-41 LINEAR DEVICES IN...19 National Semiconductor 20 Nitron 21 Raytheon 22 Sprague 23 Synertek 24 Teledyne Crystalonics 25 TRW Semiconductor 26 Zilog The following companies

  6. Optimizing the thermoelectric performance of graphene nano-ribbons without degrading the electronic properties.

    PubMed

    Tran, Van-Truong; Saint-Martin, Jérôme; Dollfus, Philippe; Volz, Sebastian

    2017-05-24

    The enhancement of thermoelectric figure of merit ZT requires to either increase the power factor or reduce the phonon conductance, or even both. In graphene, the high phonon thermal conductivity is the main factor limiting the thermoelectric conversion. The common strategy to enhance ZT is therefore to introduce phonon scatterers to suppress the phonon conductance while retaining high electrical conductance and Seebeck coefficient. Although thermoelectric performance is eventually enhanced, all studies based on this strategy show a significant reduction of the electrical conductance. In this study we demonstrate that appropriate sources of disorder, including isotopes and vacancies at lowest electron density positions, can be used as phonon scatterers to reduce the phonon conductance in graphene ribbons without degrading the electrical conductance, particularly in the low-energy region which is the most important range for device operation. By means of atomistic calculations we show that the natural electronic properties of graphene ribbons can be fully preserved while their thermoelectric efficiency is strongly enhanced. For ribbons of width M = 5 dimer lines, room-temperature ZT is enhanced from less than 0.26 to more than 2.5. This study is likely to set the milestones of a new generation of nano-devices with dual electronic/thermoelectric functionalities.

  7. 40 CFR 62.15270 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false How do I monitor the temperature of....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...

  8. 40 CFR 62.15270 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false How do I monitor the temperature of....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...

  9. 40 CFR 62.15270 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false How do I monitor the temperature of....15270 How do I monitor the temperature of flue gases at the inlet of my particulate matter control... temperature of the flue gas stream at the inlet of each particulate matter control device. ...

  10. 40 CFR 610.20 - General.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false General. 610.20 Section 610.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT... representations made with respect to retrofit devices: (a) Device functional category; (b) Device integrity; (c...

  11. 40 CFR 60.1325 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false How do I monitor the temperature of... June 6, 2001 Other Monitoring Requirements § 60.1325 How do I monitor the temperature of flue gases at... a device to continuously measure the temperature of the flue gas stream at the inlet of each...

  12. 40 CFR 60.1325 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false How do I monitor the temperature of... June 6, 2001 Other Monitoring Requirements § 60.1325 How do I monitor the temperature of flue gases at... a device to continuously measure the temperature of the flue gas stream at the inlet of each...

  13. 40 CFR 60.1325 - How do I monitor the temperature of flue gases at the inlet of my particulate matter control device?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false How do I monitor the temperature of... June 6, 2001 Other Monitoring Requirements § 60.1325 How do I monitor the temperature of flue gases at... a device to continuously measure the temperature of the flue gas stream at the inlet of each...

  14. 47 CFR 15.229 - Operation within the band 40.66-40.70 MHz.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Operation within the band 40.66-40.70 MHz. 15.229 Section 15.229 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Intentional Radiators Radiated Emission Limits, Additional Provisions § 15.229 Operation within the band 40.66...

  15. Thermoelectrics. Dense dislocation arrays embedded in grain boundaries for high-performance bulk thermoelectrics.

    PubMed

    Kim, Sang Il; Lee, Kyu Hyoung; Mun, Hyeon A; Kim, Hyun Sik; Hwang, Sung Woo; Roh, Jong Wook; Yang, Dae Jin; Shin, Weon Ho; Li, Xiang Shu; Lee, Young Hee; Snyder, G Jeffrey; Kim, Sung Wng

    2015-04-03

    The widespread use of thermoelectric technology is constrained by a relatively low conversion efficiency of the bulk alloys, which is evaluated in terms of a dimensionless figure of merit (zT). The zT of bulk alloys can be improved by reducing lattice thermal conductivity through grain boundary and point-defect scattering, which target low- and high-frequency phonons. Dense dislocation arrays formed at low-energy grain boundaries by liquid-phase compaction in Bi(0.5)Sb(1.5)Te3 (bismuth antimony telluride) effectively scatter midfrequency phonons, leading to a substantially lower lattice thermal conductivity. Full-spectrum phonon scattering with minimal charge-carrier scattering dramatically improved the zT to 1.86 ± 0.15 at 320 kelvin (K). Further, a thermoelectric cooler confirmed the performance with a maximum temperature difference of 81 K, which is much higher than current commercial Peltier cooling devices. Copyright © 2015, American Association for the Advancement of Science.

  16. Determination of Thermoelectric Module Efficiency A Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hsin; McCarty, Robin; Salvador, James R.

    2014-01-01

    The development of thermoelectrics (TE) for energy conversion is in the transition phase from laboratory research to device development. There is an increasing demand to accurately determine the module efficiency, especially for the power generation mode. For many thermoelectrics, the figure of merit, ZT, of the material sometimes cannot be fully realized at the device level. Reliable efficiency testing of thermoelectric modules is important to assess the device ZT and provide the end-users with realistic values on how much power can be generated under specific conditions. We conducted a general survey of efficiency testing devices and their performance. The resultsmore » indicated the lack of industry standards and test procedures. This study included a commercial test system and several laboratory systems. Most systems are based on the heat flow meter method and some are based on the Harman method. They are usually reproducible in evaluating thermoelectric modules. However, cross-checking among different systems often showed large errors that are likely caused by unaccounted heat loss and thermal resistance. Efficiency testing is an important area for the thermoelectric community to focus on. A follow-up international standardization effort is planned.« less

  17. Enhancing figure-of-merit of n-type Bi2Te3-xSex

    NASA Astrophysics Data System (ADS)

    Yan, Xiao; Yang, Jian; Ma, Yi; Poudel, Bed; Lan, Yucheng; Wang, Dezhi; Ren, Zhifeng; Hao, Qing; Chen, Gang

    2008-03-01

    Themoelectric materials with high dimensionless figure-of-merit (ZT) are greatly demanded in energy industry, among which bismuth telluride (Bi2Te3) exhibits decent ZT around room temperature. However, thermal conductivity of Bi2Te3 is still high which limits its wider use for low temperature cooling devices. Here we investigate nanostructured bulk n-type Bi2Te3-xSex by reducing the thermal conductivity via increased phonon scattering of the significantly increased grain boundaries due to nano size grains. We first make alloyed nanopowders by mechanical alloying a mixture of elements with the right ratio and then 100% nanostructured samples by hot press.

  18. 40 CFR 65.153 - Absorbers, condensers, carbon adsorbers, and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., an organic monitoring device capable of providing a continuous record, or an integrating regeneration... regeneration stream mass or volumetric flow for each regeneration cycle, and a carbon-bed temperature monitoring device capable of recording the carbon-bed temperature after each regeneration and within 15...

  19. 40 CFR 65.153 - Absorbers, condensers, carbon adsorbers, and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., an organic monitoring device capable of providing a continuous record, or an integrating regeneration... regeneration stream mass or volumetric flow for each regeneration cycle, and a carbon-bed temperature monitoring device capable of recording the carbon-bed temperature after each regeneration and within 15...

  20. 40 CFR 65.153 - Absorbers, condensers, carbon adsorbers, and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., an organic monitoring device capable of providing a continuous record, or an integrating regeneration... regeneration stream mass or volumetric flow for each regeneration cycle, and a carbon-bed temperature monitoring device capable of recording the carbon-bed temperature after each regeneration and within 15...

  1. 40 CFR 65.153 - Absorbers, condensers, carbon adsorbers, and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., an organic monitoring device capable of providing a continuous record, or an integrating regeneration... regeneration stream mass or volumetric flow for each regeneration cycle, and a carbon-bed temperature monitoring device capable of recording the carbon-bed temperature after each regeneration and within 15...

  2. 40 CFR 65.153 - Absorbers, condensers, carbon adsorbers, and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., an organic monitoring device capable of providing a continuous record, or an integrating regeneration... regeneration stream mass or volumetric flow for each regeneration cycle, and a carbon-bed temperature monitoring device capable of recording the carbon-bed temperature after each regeneration and within 15...

  3. 40 CFR 65.158 - Performance test procedures for control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... simultaneously from multiple loading arms, each run shall represent at least one complete tank truck or tank car... the combustion air or as a secondary fuel into a boiler or process heater with a design capacity less... corrected to 3 percent oxygen if a combustion device is the control device. (A) The emission rate correction...

  4. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  5. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  6. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  7. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  8. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  9. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Devices to indicate speed and... speed and distance. (a) Each vessel required to be fitted with an Automatic Radar Plotting Aid (ARPA) under § 164.38 of this part must be fitted with a device to indicate speed and distance of the vessel...

  10. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Devices to indicate speed and... speed and distance. (a) Each vessel required to be fitted with an Automatic Radar Plotting Aid (ARPA) under § 164.38 of this part must be fitted with a device to indicate speed and distance of the vessel...

  11. Transport properties of undoped and Br-doped PbTe sintered at high temperature and pressure> 4.0 GPa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yongkwan, Dong; McGuire, Michael A; Malik, Abds-Sami

    2009-01-01

    The thermoelectric properties of nominally undoped PbTe and Br doped PbTe materials sintered at high-pressure and high-temperature (HPHT) have been studied. All samples show n-type semiconducting behavior with negative thermopower. For undoped PbTe, four different HPHT treatments were performed at pressures between 4.0 and 6.5 GPa. PbTe doped with Br at 0.5, 1.0, 2.0, 3.0 x 10{sup 19} cm{sup -3} was HPHT treated at 4.0 GPa and 1045 C. As the dopant concentration increases, the absolute thermopower decreases, thermal conductivity increases, and electrical resistivity decreases. At a nominal dopant concentration of 1.0 x 10{sup 19} cm{sup -3}, carrier mobility ofmore » 1165 cm{sup 2}/V s and dimensionless thermoelectric figure-of-merit, ZT, of around 0.27 at 300 K were obtained. These results demonstrate that HPHT post-processing is a viable and controllable way of tuning the thermoelectric properties of PbTe-based materials.« less

  12. 10 CFR 40.5 - Communications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Communications. 40.5 Section 40.5 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF SOURCE MATERIAL General Provisions § 40.5 Communications. (a... Administrators. (ii) Health and safety design review of sealed sources and devices and approval, for licensing...

  13. Time-of-Day Dependent Neuronal Injury After Ischemic Stroke: Implication of Circadian Clock Transcriptional Factor Bmal1 and Survival Kinase AKT.

    PubMed

    Beker, Mustafa Caglar; Caglayan, Berrak; Yalcin, Esra; Caglayan, Ahmet Burak; Turkseven, Seyma; Gurel, Busra; Kelestemur, Taha; Sertel, Elif; Sahin, Zafer; Kutlu, Selim; Kilic, Ulkan; Baykal, Ahmet Tarik; Kilic, Ertugrul

    2018-03-01

    Occurrence of stroke cases displays a time-of-day variation in human. However, the mechanism linking circadian rhythm to the internal response mechanisms against pathophysiological events after ischemic stroke remained largely unknown. To this end, temporal changes in the susceptibility to ischemia/reperfusion (I/R) injury were investigated in mice in which the ischemic stroke induced at four different Zeitgeber time points with 6-h intervals (ZT0, ZT6, ZT12, and ZT18). Besides infarct volume and brain swelling, neuronal survival, apoptosis, ischemia, and circadian rhythm related proteins were examined using immunohistochemistry, Western blot, planar surface immune assay, and liquid chromatography-mass spectrometry tools. Here, we present evidence that midnight (ZT18; 24:00) I/R injury in mice resulted in significantly improved infarct volume, brain swelling, neurological deficit score, neuronal survival, and decreased apoptotic cell death compared with ischemia induced at other time points, which were associated with increased expressions of circadian proteins Bmal1, PerI, and Clock proteins and survival kinases AKT and Erk-1/2. Moreover, ribosomal protein S6, mTOR, and Bad were also significantly increased, while the levels of PRAS40, negative regulator of AKT and mTOR, and phosphorylated p53 were decreased at this time point compared to ZT0 (06:00). Furthermore, detailed proteomic analysis revealed significantly decreased CSKP, HBB-1/2, and HBA levels, while increased GNAZ, NEGR1, IMPCT, and PDE1B at midnight as compared with early morning. Our results indicate that nighttime I/R injury results in less severe neuronal damage, with increased neuronal survival, increased levels of survival kinases and circadian clock proteins, and also alters the circadian-related proteins.

  14. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... device's category will be based on: (1) Engineering principles governing operation of the device; (2... mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  15. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... device's category will be based on: (1) Engineering principles governing operation of the device; (2... mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  16. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... device's category will be based on: (1) Engineering principles governing operation of the device; (2... mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  17. Humanitarian Use Device and Humanitarian Device Exemption regulatory programs: pros and cons.

    PubMed

    Bernad, Daniel Maxwell

    2009-03-01

    The US FDA established the Humanitarian Use Device (HUD) and Humanitarian Device Exemption (HDE) program to encourage medical device firms to address rare diseases. Despite being in existence for over a decade, there has only been one peer-reviewed publication examining this field. The objective of this report is to investigate how the HUD/HDE program differs from the standard regulatory system, discuss its potential advantages and disadvantages, and to speculate which humanitarian devices will be brought to market within the next 5 years. A total of 40 semistructured interviews with stakeholders, representing approximately half (n = 20, 49%) of the firms that have successfully obtained HDE-approved products, were performed in order to acquire the primary data for this paper. There appear to be short-term gains and long-term drains associated with launching humanitarian devices to market. This report aims to provide sponsors with information that may allow them to make better decisions during their product development of humanitarian devices and may, hopefully, also play a role in encouraging other sponsors to take the necessary steps forward in helping to find treatments for patients with rare diseases.

  18. Thermoelectric materials with filled skutterudite structure for thermoelectric devices

    NASA Technical Reports Server (NTRS)

    Fleurial, Jean-Pierre (Inventor); Borshchevsky, Alex (Inventor); Caillat, Thierry (Inventor); Morelli, Donald T. (Inventor); Meisner, Gregory P. (Inventor)

    2002-01-01

    A class of thermoelectric compounds based on the skutterudite structure with heavy filling atoms in the empty octants and substituting transition metals and main-group atoms. High Seebeck coefficients and low thermal conductivities are achieved in combination with large electrical conductivities in these filled skutterudites for large ZT values. Substituting and filling methods are disclosed to synthesize skutterudite compositions with desired thermoelectric properties. A melting and/or sintering process in combination with powder metallurgy techniques is used to fabricate these new materials.

  19. Thermoelectric devices based on materials with filled skutterudite structures

    NASA Technical Reports Server (NTRS)

    Fleurial, Jean-Pierre (Inventor); Borshchevsky, Alex (Inventor); Caillat, Thierry (Inventor); Morelli, Donald T. (Inventor); Meisner, Gregory P. (Inventor)

    2003-01-01

    A class of thermoelectric compounds based on the skutterudite structure with heavy filling atoms in the empty octants and substituting transition metals and main-group atoms. High Seebeck coefficients and low thermal conductivities are achieved in combination with large electrical conductivities in these filled skutterudites for large ZT values. Substituting and filling methods are disclosed to synthesize skutterudite compositions with desired thermoelectric properties. A melting and/or sintering process in combination with powder metallurgy techniques is used to fabricate these new materials.

  20. Transport properties of undoped and Br-doped PbTe sintered at high-temperature and pressure >=4.0 GPa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, Yongkwan; McGuire, Michael A.; Malik, Abds-Sami, E-mail: abds-sami.malik@diamondinnovations.co

    2009-10-15

    The thermoelectric properties of nominally undoped PbTe and Br doped PbTe materials sintered at high-pressure and high-temperature (HPHT) have been studied. All samples show n-type semiconducting behavior with negative thermopower. For undoped PbTe, four different HPHT treatments were performed at pressures between 4.0 and 6.5 GPa. PbTe doped with Br at 0.5, 1.0, 2.0, 3.0x10{sup 19} cm{sup -3} was HPHT treated at 4.0 GPa and 1045 deg. C. As the dopant concentration increases, the absolute thermopower decreases, thermal conductivity increases, and electrical resistivity decreases. At a nominal dopant concentration of 1.0x10{sup 19} cm{sup -3}, carrier mobility of 1165 cm{sup 2}/Vmore » s and dimensionless thermoelectric figure-of-merit, ZT, of around 0.27 at 300 K were obtained. These results demonstrate that HPHT post-processing is a viable and controllable way of tuning the thermoelectric properties of PbTe-based materials. - Abstract: The effect, on thermoelectric properties, of sintering undoped and Br doped PbTe at pressures >=4.0 GPa and 1045 deg. C are reported and compared with conventionally sintered materials. Display Omitted« less

  1. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 1 Device categories Characteristics adversely affected Fuel-Air System Carburetors and fuel injection systems All. Air-fuel ratio modifiers (e.g., air bleeds) All. Atomization devices (acoustic and mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  2. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 1 Device categories Characteristics adversely affected Fuel-Air System Carburetors and fuel injection systems All. Air-fuel ratio modifiers (e.g., air bleeds) All. Atomization devices (acoustic and mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  3. A 40-foot static cone penetrometer

    USGS Publications Warehouse

    Beard, R.M.; Lee, H.J.

    1982-01-01

    The Navy needs a lightweight device for testing seafloor soils to sub bottom depths of 12 meters in water depths to 60 meters. To meet this need a quasistatic cone penetration device that uses water jetting to reduce friction on the cone rod has been developed. This device is called the XSP-40. The 5-ton XSP-40 stands 15 meters tall and pushes a standard 5-ton cone into the seafloor. It is remotely controlled with an electronic unit on the deck of the support vessel. All cone outputs are recorded directly as a function of penetration depth with a strip chart recorder. A full suite of gauges is provided. on the electronic unit for monitoring the XSP-40's performance during a test .. About 40 penetration tests have been performed with very good success. The XSP-40 was field tested in Norton Sound, off the west coast of Alaska. The general objective, in addition to evaluation of the device, was to gather geotechnical information on sediments that may be involved in processes potentially hazardous to offshore development. Four example penetration records are presented from gas charged sediment zones and areas near the Yukon River delta. In general it was determined that soil classification from cone data agreed well with classifications from core samples. Relative densities of the silt-sand to sandy-silt soils were usually very high. The significance of these results are discussed with respect to storm wave, liquefaction. It is concluded that the XSP-40 is a durable and reliable piece of equipment capable of achieving penetration beyond that possible when not using the water jet system.

  4. Temperature Dependence of the Seebeck Coefficient in Zinc Oxide Thin Films

    NASA Astrophysics Data System (ADS)

    Noori, Amirreza; Masoumi, Saeed; Hashemi, Najmeh

    2017-12-01

    Thermoelectric devices are reliable tools for converting waste heat into electricity as they last long, produce no noise or vibration, have no moving elements, and their light weight makes them suitable for the outer space usage. Materials with high thermoelectric figure of merit (zT) have the most important role in the fabrication of efficient thermoelectric devices. Metal oxide semiconductors, specially zinc oxide has recently received attention as a material suitable for sensor, optoelectronic and thermoelectric device applications because of their wide direct bandgap, chemical stability, high-energy radiation endurance, transparency and acceptable zT. Understanding the thermoelectric properties of the undoped ZnO thin films can help design better ZnO-based devices. Here, we report the results of our experimental work on the thermoelectric properties of the undoped polycrystalline ZnO thin films. These films are deposited on alumina substrates by thermal evaporation of zinc in vacuum followed by a controlled oxidation process in air carried out at the 350-500 °C temperature range. The experimental setup including gradient heaters, thermometry system and Seebeck voltage measurement equipment for high resistance samples is described. Seebeck voltage and electrical resistivity of the samples are measured at different conditions. The observed temperature dependence of the Seebeck coefficient is discussed.

  5. On the best bandstructure for thermoelectric performance: A Landauer perspective

    NASA Astrophysics Data System (ADS)

    Jeong, Changwook; Kim, Raseong; Lundstrom, Mark S.

    2012-06-01

    The question of what bandstructure produces the best thermoelectric device performance is revisited from a Landauer perspective. We find that a delta-function transport distribution function (TDF) results in operation at the Mahan-Sofo upper limit for the thermoelectric figure-of-merit, ZT. We show, however, the Mahan-Sofo upper limit itself depends on the bandwidth (BW) of the dispersion, and therefore, a finite BW dispersion produces a higher ZT when the lattice thermal conductivity is finite. Including a realistic model for scattering profoundly changes the results. Instead of a narrow band, we find that a broad BW is best. The prospects of increasing ZT through high valley degeneracy or by distorting the density-of-states are discussed from a Landauer perspective. We conclude that while there is no simple answer to the question of what bandstructure produces the best thermoelectric performance, the important considerations can be expressed in terms of three parameters derived from the bandstructure—the density-of-states, D(E ), the number of channels, M(E ), and the mean-free-path, λ(E ).

  6. Thickness-controlled electronic structure and thermoelectric performance of ultrathin SnS2 nanosheets.

    PubMed

    Li, Jun; Shen, Jinni; Ma, Zuju; Wu, Kechen

    2017-08-21

    The thermoelectric conversion efficiency of a material relies on a dimensionless parameter (ZT = S 2 σT/κ). It is a great challenge in enhancing the ZT value basically due to that the related transport factors of most of the bulk materials are inter-conditioned to each other, making it very difficult to simultaneously optimize these parameters. In this report, the negative correlation between power factor and thermal conductivity of nano-scaled SnS 2 multilayers is predicted by high-level first-principle computations combined with Boltzmann transport theory. By diminishing the thickness of SnS 2 nanosheet to about 3 L, the S and σ along a direction simultaneously increase whereas κ decreases, achieving a high ZT value of 1.87 at 800 K. The microscopic mechanisms for this unusual negative correlation in nano-scaled two dimensional (2D) material are elucidated and attributed to the quantum confinement effect. The results may open a way to explore the high ZT thermoelectric nano-devices for the practical thermoelectric applications.

  7. Decouple electronic and phononic transport in nanotwinned structures: a new strategy for enhancing the figure-of-merit of thermoelectrics.

    PubMed

    Zhou, Yanguang; Gong, Xiaojing; Xu, Ben; Hu, Ming

    2017-07-20

    Thermoelectric (TE) materials manifest themselves to enable direct conversion of temperature differences to electric power and vice versa. Though remarkable advances have been achieved in the past decades for various TE systems, the energy conversion efficiency of TE devices, which is characterized by a dimensionless figure-of-merit (ZT = S 2 σT/(κ el + κ ph )), generally remains a poor factor that severely limits TE devices' competitiveness and range of employment. The bottleneck for substantially boosting the ZT coefficient lies in the strong interdependence of the physical parameters involved in electronic (S and σ, and κ el ) and phononic (κ ph ) transport. Herein, we propose a new strategy of incorporating nanotwinned structures to decouple electronic and phononic transport. Combining the new concept of nanotwinned structures with the previously widely used nanocrystalline approach, the power factor of the nanotwin-nanocrystalline Si heterostructures is enhanced by 120% compared to that of bulk crystalline Si, while the lattice thermal conductivity is reduced to a level well below the amorphous limit, yielding a theoretical limit of 0.52 and 0.9 for ZT coefficient at room temperature and 1100 K, respectively. This value is almost two orders of magnitude larger than that for bulk Si and twice that for polycrystalline Si. Even for the experimentally obtained nanotwin-nanocrystalline heterostructures (e.g. grain size of 5 nm), the ZT coefficient can be as high as 0.26 at room temperature and 0.7 at 1100 K, which is the highest ZT value among all Si-based bulk nanostructures found thus far. Such substantial improvement stems from two aspects: (1) the improvement in the power factor is caused due to an increase in the Seebeck coefficient (degeneracy of the band valley) and the enhancement of electrical conductivity (the reduction of the effective band mass) and (2) the significant reduction of the lattice thermal conductivity is mainly caused due to the

  8. First principles study of thermoelectric properties of IV-VI semiconductor superlattices

    NASA Astrophysics Data System (ADS)

    Borges, P. D.; Petersen, J. E.; Scolfaro, L.; Leite Alves, H. W.; Myers, T. H.

    2015-03-01

    Thermoelectric materials (TE) have attracted great attention due to their ability to convert heat directly into electricity. However, to be commercially competitive with existing technology, TE devices must have a higher value of figure of merit ZT. It has been proposed to improve ZT by using multilayered systems or superlattices (SLs) resulting in 1D or 2D carrier confinement, reduction of the phonon thermal conductivity, and introduction of anisotropy effects. Here we study the TE properties of IV-VI derived semiconductor SLs. By using the Boltzmann transport theory, within the constant scattering time approximation, in conjunction with first principles calculations, we study the Seebeck coefficient (S) and ZT of PbTe/SnTe SLs. The calculated S shows good agreement with recent experimental data. An anisotropic behavior is observed for low carrier concentrations less than 10⌃18cm⌃-3. For T = 900 K, a large value of ZTparallel to the SL axis equal to 2.6 is predicted for n =1.2x10⌃18cm⌃-3, whereas ZT perpendicular to the SL axis peaks at the value 1.4 for n =5.5x10⌃17 cm⌃-3. Both electrical conductivity enhancement and reduction of thermal conductivity are analyzed, and a comparison with other multilayered systems such as planar-doped PbTe is done. Support from CNPq and Texas State University.

  9. 40 CFR 65.146 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.146 Nonflare control devices used for equipment leaks only...

  10. 40 CFR 265.383 - Interim status thermal treatment devices burning particular hazardous waste.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... devices burning particular hazardous waste. 265.383 Section 265.383 Protection of Environment... status thermal treatment devices burning particular hazardous waste. (a) Owners or operators of thermal treatment devices subject to this subpart may burn EPA Hazardous Wastes FO20, FO21, FO22, FO23, FO26, or...

  11. 40 CFR 265.383 - Interim status thermal treatment devices burning particular hazardous waste.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... devices burning particular hazardous waste. 265.383 Section 265.383 Protection of Environment... status thermal treatment devices burning particular hazardous waste. (a) Owners or operators of thermal treatment devices subject to this subpart may burn EPA Hazardous Wastes FO20, FO21, FO22, FO23, FO26, or...

  12. 40 CFR 265.383 - Interim status thermal treatment devices burning particular hazardous waste.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... devices burning particular hazardous waste. 265.383 Section 265.383 Protection of Environment... status thermal treatment devices burning particular hazardous waste. (a) Owners or operators of thermal treatment devices subject to this subpart may burn EPA Hazardous Wastes FO20, FO21, FO22, FO23, FO26, or...

  13. 40 CFR 265.383 - Interim status thermal treatment devices burning particular hazardous waste.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... devices burning particular hazardous waste. 265.383 Section 265.383 Protection of Environment... status thermal treatment devices burning particular hazardous waste. (a) Owners or operators of thermal treatment devices subject to this subpart may burn EPA Hazardous Wastes FO20, FO21, FO22, FO23, FO26, or...

  14. 40 CFR 265.383 - Interim status thermal treatment devices burning particular hazardous waste.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... devices burning particular hazardous waste. 265.383 Section 265.383 Protection of Environment... status thermal treatment devices burning particular hazardous waste. (a) Owners or operators of thermal treatment devices subject to this subpart may burn EPA Hazardous Wastes FO20, FO21, FO22, FO23, FO26, or...

  15. 40 CFR 140.5 - Analytical procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 140.5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) MARINE SANITATION DEVICE STANDARD § 140.5 Analytical procedures. In determining the composition and quality of effluent discharge from marine sanitation devices, the procedures contained in 40 CFR part 136...

  16. 49 CFR 572.40 - Incorporated materials.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Incorporated materials. 572.40 Section 572.40 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side Impact Dummy 50th...

  17. 49 CFR 572.40 - Incorporated materials.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Incorporated materials. 572.40 Section 572.40 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side Impact Dummy 50th...

  18. 49 CFR 572.40 - Incorporated materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Incorporated materials. 572.40 Section 572.40 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side Impact Dummy 50th...

  19. Large-Vessel Sealing in Laparoscopic Colectomy with an Ultrasonic Device

    PubMed Central

    Plasencia, Gustavo; Van der Speeten, Kurt; Hinoul, Piet; Batiller, Jonathan; Severin, Kimberley S.; Schwiers, Michael L.; Rockall, Tim

    2016-01-01

    Background and Objective: The Harmonic ACE+7 Shears with Advanced Hemostasis Mode (Ethicon, Somerville, NJ, USA) is an ultrasonic device designed to transect and seal vessels up to 7 mm in diameter. The device applies an algorithm that optimizes ultrasonic energy delivery combined with a longer sealing cycle. The purpose of this study was to assess the initial clinical experience with the Harmonic device by evaluating large-vessel sealing during laparoscopic colectomy in consecutive cases. Methods: This prospective, multicenter, observational series involved 40 adult patients who were to undergo elective laparoscopic colectomy where dissection and transection of the inferior mesenteric artery was indicated. The primary study endpoint was first-pass hemostasis, defined as a single activation of the Advanced Hemostasis Mode to transect and seal the inferior mesenteric artery. The use of any additional energy device or hemostatic product to establish or maintain hemostasis was noted. Patients were observed after surgery for ∼4 weeks for adverse events that were considered to be related to the study procedure or study device. Descriptive statistical analyses were performed for study endpoints. Results: Forty patients underwent the laparoscopic colectomy procedure. First-pass hemostasis of the inferior mesenteric artery was achieved and maintained in all 40 patients, with no required additional hemostatic measures. Exposure of the vessel was reported as skeletonized in 22 of 40 (55%) patients. Mean transection time was 21.9 ± 7.4 s. One adverse event (postoperative anemia) was considered possibly related to the study device. Conclusion: In this initial clinical consecutive series, the device demonstrated successful transection and sealing of the large mesenteric vessels during laparoscopic colorectal surgery. PMID:27186065

  20. 40 CFR 264.1054 - Standards: Pressure relief devices in gas/vapor service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... gas/vapor service. 264.1054 Section 264.1054 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE... relief devices in gas/vapor service. (a) Except during pressure releases, each pressure relief device in...

  1. 40 CFR 86.1809-12 - Prohibition of defeat devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light... device. (c) For cold temperature CO and cold temperature NMHC emission control, the Administrator will...

  2. 40 CFR 86.1809-10 - Prohibition of defeat devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light... device. (c) For cold temperature CO and cold temperature NMHC emission control, the Administrator will...

  3. 40 CFR 86.1809-12 - Prohibition of defeat devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light... device. (c) For cold temperature CO and cold temperature NMHC emission control, the Administrator will...

  4. 40 CFR 86.1809-10 - Prohibition of defeat devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light... device. (c) For cold temperature CO and cold temperature NMHC emission control, the Administrator will...

  5. 40 CFR 86.1809-10 - Prohibition of defeat devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light... device. (c) For cold temperature CO and cold temperature NMHC emission control, the Administrator will...

  6. 40 CFR 86.1809-12 - Prohibition of defeat devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light... device. (c) For cold temperature CO and cold temperature NMHC emission control, the Administrator will...

  7. 40 CFR 610.33 - Durability tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Durability tests. 610.33 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.33 Durability tests. The Administrator may determine that a device under evaluation will require durability testing in...

  8. 40 CFR 610.33 - Durability tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Durability tests. 610.33 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.33 Durability tests. The Administrator may determine that a device under evaluation will require durability testing in...

  9. 40 CFR 610.33 - Durability tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Durability tests. 610.33 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.33 Durability tests. The Administrator may determine that a device under evaluation will require durability testing in...

  10. 40 CFR 610.33 - Durability tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Durability tests. 610.33 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.33 Durability tests. The Administrator may determine that a device under evaluation will require durability testing in...

  11. 40 CFR 60.692-5 - Standards: Closed vent systems and control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (for example, condensers and adsorbers) shall be designed and operated to recover the VOC emissions... systems and control devices. (a) Enclosed combustion devices shall be designed and operated to reduce the... them. (e)(1) Closed vent systems shall be designed and operated with no detectable emissions, as...

  12. 27 CFR 479.40 - Partnership liability.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2013-04-01 2013-04-01 false Partnership liability. 479.40 Section 479.40 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN...

  13. 27 CFR 479.40 - Partnership liability.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Partnership liability. 479.40 Section 479.40 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN...

  14. 27 CFR 479.40 - Partnership liability.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2014-04-01 2014-04-01 false Partnership liability. 479.40 Section 479.40 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN...

  15. 27 CFR 479.40 - Partnership liability.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2011-04-01 2010-04-01 true Partnership liability. 479.40 Section 479.40 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN...

  16. 27 CFR 479.40 - Partnership liability.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2012-04-01 2010-04-01 true Partnership liability. 479.40 Section 479.40 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN...

  17. Doctors and the Etiquette of Mobile Device Use in Trauma and Orthopedics.

    PubMed

    Blocker, Oliver; Hayden, Lydia; Bullock, Alison

    2015-06-26

    The etiquette surrounding the use of mobile devices, so-called "mobiquette," has been previously identified as a barrier to use in an educational context. To investigate the influence of mobile device use on patient and staff opinions in the trauma and orthopedics department at a teaching hospital in Wales. A survey of patients at the bedside and staff in their work environment was undertaken. Data included age, frequency of observed use, suspected main reason for use, and whether doctors' use of a mobile device positively or negatively influenced participants' opinions of them as a professional and as a person. A total of 59 patients and 35 staff responded. The modal age range was 40 to 54 years old. Most patients (78%) never see doctors using mobile devices in the workplace, compared with 3% of staff. The main reason for use was thought to be "communicating with colleagues" (48%) followed by "Internet use/applications for work reasons" (40%). Approximately 40% of patients' opinions of doctors were positively influenced by device use, compared with 82% of staff. This difference between patient and staff opinions was statistically significant for both professional (P<.001) and personal (P=.002) opinions. Patients are likely to have a negative opinion of doctors using mobile devices in the workplace. This can be balanced by the more positive opinions of colleagues. We advise doctors to remember "mobiquette" around patients.

  18. 40 CFR 610.41 - Test configurations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Test configurations. 610.41 Section... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.41 Test configurations. (a) In order to measure the effectiveness of a retrofit device at least two, and...

  19. 40 CFR 610.41 - Test configurations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Test configurations. 610.41 Section... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.41 Test configurations. (a) In order to measure the effectiveness of a retrofit device at least two, and...

  20. 40 CFR 610.41 - Test configurations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Test configurations. 610.41 Section... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.41 Test configurations. (a) In order to measure the effectiveness of a retrofit device at least two, and...

  1. 40 CFR 610.41 - Test configurations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Test configurations. 610.41 Section... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.41 Test configurations. (a) In order to measure the effectiveness of a retrofit device at least two, and...

  2. 40 CFR 211.208 - Export provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Export provisions. 211.208 Section 211... PRODUCT NOISE LABELING Hearing Protective Devices § 211.208 Export provisions. (a) The outside of each package or container containing a hearing protective device intended solely for export must be so labeled...

  3. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests. The effect of a device on a vehicle's performance will be determined by performing wide-open-throttle...

  4. Nanowire Thermoelectric Devices

    NASA Technical Reports Server (NTRS)

    Borshchevsky, Alexander; Fleurial, Jean-Pierre; Herman, Jennifer; Ryan, Margaret

    2005-01-01

    Nanowire thermoelectric devices, now under development, are intended to take miniaturization a step beyond the prior state of the art to exploit the potential advantages afforded by shrinking some device features to approximately molecular dimensions (of the order of 10 nm). The development of nanowire-based thermoelectric devices could lead to novel power-generating, cooling, and sensing devices that operate at relatively low currents and high voltages. Recent work on the theory of thermoelectric devices has led to the expectation that the performance of such a device could be enhanced if the diameter of the wires could be reduced to a point where quantum confinement effects increase charge-carrier mobility (thereby increasing the Seebeck coefficient) and reduce thermal conductivity. In addition, even in the absence of these effects, the large aspect ratios (length of the order of tens of microns diameter of the order of tens of nanometers) of nanowires would be conducive to the maintenance of large temperature differences at small heat fluxes. The predicted net effect of reducing diameters to the order of tens of nanometers would be to increase its efficiency by a factor of .3. Nanowires made of thermoelectric materials and devices that comprise arrays of such nanowires can be fabricated by electrochemical growth of the thermoelectric materials in templates that contain suitably dimensioned pores (10 to 100 nm in diameter and 1 to 100 microns long). The nanowires can then be contacted in bundles to form devices that look similar to conventional thermoelectric devices, except that a production version may contain nearly a billion elements (wires) per square centimeter, instead of fewer than a hundred as in a conventional bulk thermoelectric device or fewer than 100,000 as in a microdevice. It is not yet possible to form contacts with individual nanowires. Therefore, in fabricating a nanowire thermoelectric device, one forms contacts on nanowires in bundles of the

  5. 40 CFR 65.154 - Halogen scrubbers and other halogen reduction devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... which it is part, as specified in 40 CFR 63.100(k) (if the referencing subpart is 40 CFR part 63... anticipated in the scrubber during representative operating conditions other than startups, shutdowns, or...

  6. Resistive switching characteristics of polymer non-volatile memory devices in a scalable via-hole structure.

    PubMed

    Kim, Tae-Wook; Choi, Hyejung; Oh, Seung-Hwan; Jo, Minseok; Wang, Gunuk; Cho, Byungjin; Kim, Dong-Yu; Hwang, Hyunsang; Lee, Takhee

    2009-01-14

    The resistive switching characteristics of polyfluorene-derivative polymer material in a sub-micron scale via-hole device structure were investigated. The scalable via-hole sub-microstructure was fabricated using an e-beam lithographic technique. The polymer non-volatile memory devices varied in size from 40 x 40 microm(2) to 200 x 200 nm(2). From the scaling of junction size, the memory mechanism can be attributed to the space-charge-limited current with filamentary conduction. Sub-micron scale polymer memory devices showed excellent resistive switching behaviours such as a large ON/OFF ratio (I(ON)/I(OFF) approximately 10(4)), excellent device-to-device switching uniformity, good sweep endurance, and good retention times (more than 10,000 s). The successful operation of sub-micron scale memory devices of our polyfluorene-derivative polymer shows promise to fabricate high-density polymer memory devices.

  7. 40 CFR 503.41 - Special definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... device in which organic matter and inorganic matter in sewage sludge are combusted in a bed of particles... combustion of organic matter and inorganic matter in sewage sludge by high temperatures in an enclosed device... accordance with 40 CFR 51.100 (ii). (p) Total hydrocarbons means the organic compounds in the exit gas from a...

  8. 40 CFR 503.41 - Special definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... device in which organic matter and inorganic matter in sewage sludge are combusted in a bed of particles... combustion of organic matter and inorganic matter in sewage sludge by high temperatures in an enclosed device... accordance with 40 CFR 51.100 (ii). (p) Total hydrocarbons means the organic compounds in the exit gas from a...

  9. 40 CFR 503.41 - Special definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... device in which organic matter and inorganic matter in sewage sludge are combusted in a bed of particles... combustion of organic matter and inorganic matter in sewage sludge by high temperatures in an enclosed device... accordance with 40 CFR 51.100 (ii). (p) Total hydrocarbons means the organic compounds in the exit gas from a...

  10. 40 CFR 503.41 - Special definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... device in which organic matter and inorganic matter in sewage sludge are combusted in a bed of particles... combustion of organic matter and inorganic matter in sewage sludge by high temperatures in an enclosed device... accordance with 40 CFR 51.100 (ii). (p) Total hydrocarbons means the organic compounds in the exit gas from a...

  11. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  12. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  13. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  14. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  15. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  16. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  17. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  18. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  19. 40 CFR 89.409 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 89.409 Section 89.409... Data logging. (a) A computer or any other automatic data processing device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection records the...

  20. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  1. 40 CFR 211.204-4 - Supporting information.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Supporting information. 211.204-4... PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.204-4 Supporting information. The following minimum supporting information must accompany the device in a manner that insures its availability...

  2. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  3. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  4. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  5. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  6. 40 CFR 91.412 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 91.412 Section 91.412... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the...

  7. GaN Nanowire Devices: Fabrication and Characterization

    NASA Astrophysics Data System (ADS)

    Scott, Reum

    The development of microelectronics in the last 25 years has been characterized by an exponential increase of the bit density in integrated circuits (ICs) with time. Scaling solid-state devices improves cost, performance, and power; as such, it is of particular interest for companies, who gain a market advantage with the latest technology. As a result, the microelectronics industry has driven transistor feature size scaling from 10 μm to ~30 nm during the past 40 years. This trend has persisted for 40 years due to optimization, new processing techniques, device structures, and materials. But when noting processor speeds from the 1970's to 2009 and then again in 2010, the implication would be that the trend has ceased. To address the challenge of shrinking the integrated circuit (IC), current research is centered on identifying new materials and devices that can supplement and/or potentially supplant it. Bottom-up methods tailor nanoscale building blocks---atoms, molecules, quantum dots, and nanowires (NWs)---to be used to overcome these limitations. The Group IIIA nitrides (InN, AlN, and GaN) possess appealing properties such as a direct band gap spanning the whole solar spectrum, high saturation velocity, and high breakdown electric field. As a result nanostructures and nanodevices made from GaN and related nitrides are suitable candidates for efficient nanoscale UV/ visible light emitters, detectors, and gas sensors. To produce devices with such small structures new fabrication methods must be implemented. Devices composed of GaN nanowires were fabricated using photolithography and electron beam lithography. The IV characteristics of these devices were noted under different illuminations and the current tripled from 4.8*10-7 A to 1.59*10 -6 A under UV light which persisted for at least 5hrs.

  8. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  9. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  10. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  11. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  12. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  13. Model-based assist feature insertion for sub-40nm memory device

    NASA Astrophysics Data System (ADS)

    Suh, Sungsoo; Lee, Suk-joo; Choi, Seong-woon; Lee, Sung-Woo; Park, Chan-hoon

    2009-04-01

    Many issues need to be resolved for a production-worthy model based assist feature insertion flow for single and double exposure patterning process to extend low k1 process at 193 nm immersion technology. Model based assist feature insertion is not trivial to implement either for single and double exposure patterning compared to rule based methods. As shown in Fig. 1, pixel based mask inversion technology in itself has difficulties in mask writing and inspection although it presents as one of key technology to extend single exposure for contact layer. Thus far, inversion technology is tried as a cooptimization of target mask to simultaneously generate optimized main and sub-resolution assists features for a desired process window. Alternatively, its technology can also be used to optimize for a target feature after an assist feature types are inserted in order to simplify the mask complexity. Simplification of inversion mask is one of major issue with applying inversion technology to device development even if a smaller mask feature can be fabricated since the mask writing time is also a major factor. As shown in Figure 2, mask writing time may be a limiting factor in determining whether or not an inversion solution is viable. It can be reasoned that increased number of shot counts relates to increase in margin for inversion methodology. On the other hand, there is a limit on how complex a mask can be in order to be production worthy. There is also source and mask co-optimization which influences the final mask patterns and assist feature sizes and positions for a given target. In this study, we will discuss assist feature insertion methods for sub 40-nm technology.

  14. Evaluation of pharmacokinetics, user handling, and tolerability of peginterferon alfa-2a (40 kDa) delivered via a disposable autoinjector device

    PubMed Central

    Varunok, Peter; Lawitz, Eric; Beavers, Kimberly L; Matusow, Gary; Leong, Ruby; Lambert, Nathalie; Bernaards, Coen; Solsky, Jonathan; Brennan, Barbara J; Wat, Cynthia; Bertasso, Anne

    2011-01-01

    Background Peginterferon alfa-2a (40 kDa) is currently administered using a prefilled syringe. The peginterferon alfa-2a disposable autoinjector is a new safety-engineered device designed to facilitate injection and reduce the risk of needlestick injuries. The analysis of two open-label Phase I trials evaluated the pharmacokinetics, successful administration, and tolerability of peginterferon alfa-2a when using the autoinjector. The studies were performed to support the filing and registration of the autoinjector device. Methods In trial 1, 50 healthy adult subjects received one 180 μg dose of peginterferon alfa-2a via the autoinjector. Serial blood samples were collected predose, up to 336 hours following drug administration, and at follow-up (28 ± 3 days post-dosing) for noncompartmental pharmacokinetic analysis. Trial 2 randomized 60 adult patients with chronic hepatitis C to 180 μg peginterferon alfa-2a once weekly by the autoinjector or prefilled syringe for 3 weeks followed by the alternative device (prefilled syringe or autoinjector, respectively) for 3 weeks. Patients also received ribavirin. Administration by the devices was evaluated under direct observation by a study staff member and by patient subjective assessment. Results In trial 1, following a single dose of peginterferon alfa-2a, the maximum plasma concentration was 16.1 ± 5.3 ng/mL (mean ± standard deviation), and area under the concentration time curve (0–168 hours) was 1996 ± 613 ng · hour/mL, similar to that reported using a vial/syringe or prefilled syringe. In trial 2, few patients showed handling difficulties with either device. Generally, patients were observed to be more satisfied and confident, followed instructions better, and successfully initiated injection with the autoinjector versus the prefilled syringe. Patients reported the autoinjector to be more convenient and easier to use. No pain or discomfort was experienced using the autoinjector. The autoinjector safety profile

  15. 40 CFR 65.152 - Carbon adsorbers used as control devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better capable of recording the total regeneration stream mass or volumetric flow for each regeneration... after each regeneration and within 15 minutes of completing any cooling cycle, shall be used. Monitoring...

  16. 40 CFR 65.152 - Carbon adsorbers used as control devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better capable of recording the total regeneration stream mass or volumetric flow for each regeneration... after each regeneration and within 15 minutes of completing any cooling cycle, shall be used. Monitoring...

  17. 40 CFR 65.152 - Carbon adsorbers used as control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better capable of recording the total regeneration stream mass or volumetric flow for each regeneration... after each regeneration and within 15 minutes of completing any cooling cycle, shall be used. Monitoring...

  18. 40 CFR 65.152 - Carbon adsorbers used as control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better capable of recording the total regeneration stream mass or volumetric flow for each regeneration... after each regeneration and within 15 minutes of completing any cooling cycle, shall be used. Monitoring...

  19. 40 CFR 63.983 - Closed vent systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Closed vent systems. 63.983 Section 63... Emission Standards for Closed Vent Systems, Control Devices, Recovery Devices and Routing to a Fuel Gas System or a Process § 63.983 Closed vent systems. (a) Closed vent system equipment and operating...

  20. 40 CFR 63.997 - Performance test and compliance assessment requirements for control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...), each run shall represent at least one complete tank truck or tank car loading period, during which... stream is introduced with the combustion air or as a secondary fuel into a boiler or process heater with... specified in paragraph (e)(2)(iii)(C) of this section if a combustion device is the control device and...

  1. No Escaping the Rat Race: Simulated Night Shift Work Alters the Time-of-Day Variation in BMAL1 Translational Activity in the Prefrontal Cortex.

    PubMed

    Marti, Andrea R; Patil, Sudarshan; Mrdalj, Jelena; Meerlo, Peter; Skrede, Silje; Pallesen, Ståle; Pedersen, Torhild T; Bramham, Clive R; Grønli, Janne

    2017-01-01

    Millions of people worldwide work during the night, resulting in disturbed circadian rhythms and sleep loss. This may cause deficits in cognitive functions, impaired alertness and increased risk of errors and accidents. Disturbed circadian rhythmicity resulting from night shift work could impair brain function and cognition through disrupted synthesis of proteins involved in synaptic plasticity and neuronal function. Recently, the circadian transcription factor brain-and-muscle arnt-like protein 1 (BMAL1) has been identified as a promoter of mRNA translation initiation, the most highly regulated step in protein synthesis, through binding to the mRNA "cap". In this study we investigated the effects of simulated shift work on protein synthesis markers. Male rats ( n = 40) were exposed to forced activity, either in their rest phase (simulated night shift work) or in their active phase (simulated day shift work) for 3 days. Following the third work shift, experimental animals and time-matched undisturbed controls were euthanized (rest work at ZT12; active work at ZT0). Tissue lysates from two brain regions (prefrontal cortex, PFC and hippocampus) implicated in cognition and sleep loss, were analyzed with m 7 GTP (cap) pull-down to examine time-of-day variation and effects of simulated shift work on cap-bound protein translation. The results show time-of-day variation of protein synthesis markers in PFC, with increased protein synthesis at ZT12. In the hippocampus there was little difference between ZT0 and ZT12. Active phase work did not induce statistically significant changes in protein synthesis markers at ZT0 compared to time-matched undisturbed controls. Rest work, however, resulted in distinct brain-region specific changes of protein synthesis markers compared to time-matched controls at ZT12. While no changes were observed in the hippocampus, phosphorylation of cap-bound BMAL1 and its regulator S6 kinase beta-1 (S6K1) was significantly reduced in the PFC

  2. Time-of-Day Dictates Transcriptional Inflammatory Responses to Cytotoxic Chemotherapy

    PubMed Central

    Borniger, Jeremy C.; Walker II, William H.; Gaudier-Diaz, Monica M.; Stegman, Curtis J.; Zhang, Ning; Hollyfield, Jennifer L.; Nelson, Randy J.; DeVries, A. Courtney

    2017-01-01

    Many cytotoxic chemotherapeutics elicit a proinflammatory response which is often associated with chemotherapy-induced behavioral alterations. The immune system is under circadian influence; time-of-day may alter inflammatory responses to chemotherapeutics. We tested this hypothesis by administering cyclophosphamide and doxorubicin (Cyclo/Dox), a common treatment for breast cancer, to female BALB/c mice near the beginning of the light or dark phase. Mice were injected intravenously with Cyclo/Dox or the vehicle two hours after lights on (zeitgeber time (ZT2), or two hours after lights off (ZT14). Tissue was collected 1, 3, 9, and 24 hours later. Mice injected with Cyclo/Dox at ZT2 lost more body mass than mice injected at ZT14. Cyclo/Dox injected at ZT2 increased the expression of several pro-inflammatory genes within the spleen; this was not evident among mice treated at ZT14. Transcription of enzymes within the liver responsible for converting Cyclo/Dox into their toxic metabolites increased among mice injected at ZT2; furthermore, transcription of these enzymes correlated with splenic pro-inflammatory gene expression when treatment occurred at ZT2 but not ZT14. The pattern was reversed in the brain; pro-inflammatory gene expression increased among mice injected at ZT14. These data suggest that inflammatory responses to chemotherapy depend on time-of-day and are tissue specific. PMID:28117419

  3. 40 CFR 63.2251 - What are the requirements for the routine control device maintenance exemption?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the routine control device maintenance exemption? (a) You may request a routine control device..., explain why the maintenance cannot be accomplished during process shutdowns, describe how you plan to make... device is used to control a green rotary dryer, tube dryer, rotary strand dryer, or pressurized refiner...

  4. Thermoelectric properties of the electron-doped perovskites Sr1-xCaxTi1-yNbyO3

    NASA Astrophysics Data System (ADS)

    Fukuyado, J.; Narikiyo, K.; Akaki, M.; Kuwahara, H.; Okuda, T.

    2012-02-01

    We have investigated thermoelectric (TE) properties for single crystals of perovskites Sr1-xCaxTi1-yNbyO3 for 0 ⩽ x ⩽ 0.4 and 0 ⩽ y ⩽ 0.03 below room temperature (RT). We found that SrTi0.99Nb0.01O3 shows a large power factor at low temperature (PF=50 μW/K2 cm at 100 K ˜ 90 μW/K2 cm at 50 K) and the largest dimensionless TE figure-of-merit below 40 K (ZT ˜ 0.07) among the ever-reported materials. Such a large low-temperature TE response around a carrier concentration of 1020 cm-3 is due to a distinct electron-phonon interaction, which could relate to the superconducting state. We also found that the Ca2+ substitution for Sr2+ increases ZT at 300 K for Sr1-xCaxTi0.97Nb0.03O3 from 0.08 to 0.105. The enhancement of ZT around RT originates both in a large reduction of a thermal conductivity due to an introduced randomness into the crystal structure and in an unexpected enhancement of a Seebeck coefficient.

  5. 40 CFR 65.158 - Performance test procedures for control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... regulated material or as TOC (minus methane and ethane) according to the procedures specified. (1) Method 1... material or TOC, sampling sites shall be located at the inlet of the control device as specified in the... sampling sites shall ensure the measurement of total regulated material or TOC (minus methane and ethane...

  6. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., when the vessel is operating free from shallow water effect, and from the effects of wind, current, and...) Errors in the indicated distance run, when the vessel is operating free from shallow water effect, and... either through the water or over the ground. (b) The device must meet the following specifications: (1...

  7. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., when the vessel is operating free from shallow water effect, and from the effects of wind, current, and...) Errors in the indicated distance run, when the vessel is operating free from shallow water effect, and... either through the water or over the ground. (b) The device must meet the following specifications: (1...

  8. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., when the vessel is operating free from shallow water effect, and from the effects of wind, current, and...) Errors in the indicated distance run, when the vessel is operating free from shallow water effect, and... either through the water or over the ground. (b) The device must meet the following specifications: (1...

  9. Mechanisms of cadmium-induced chronotoxicity in mice.

    PubMed

    Miura, Nobuhiko; Ashimori, Atsushige; Takeuchi, Asuka; Ohtani, Katsumi; Takada, Naoko; Yanagiba, Yukie; Mita, Masaharu; Togawa, Masako; Hasegawa, Tatsuya

    2013-01-01

    Biological defense factors show diurnal variations in their expression levels or activities. These variations can induce the different sensitivity to external toxicants of a day. We reported earlier that mice showed clear diurnal variation of cadmium (Cd)-induced toxicity, i.e., chronotoxicity. In this report, we investigated additional new evidences for the cadmium (Cd)-induced chronotoxicity, and considered the mechanisms contributed to this chronotoxicity. Male C57BL/6J mice were injected with CdCl₂ (6.4 mg/kg, one shot) intraperitoneally at 6 different time points of a day (zeitgeber time (ZT); ZT2, ZT6, ZT10, ZT14, ZT18 or ZT22) followed by monitoring the mortality until 14 days after the injection. We observed extreme difference in survival numbers: surprisingly, all mice died at ZT2 injection while all mice survived at ZT18 injection. Moreover, in non-lethal dose of Cd (4.5 mg/kg), the values of alanine aminotransferase (ALT) and aspartate aminotransferase (AST) used as indexes of hepatotoxicity markedly increased at ZT6 injection while mostly unchanged at ZT18 injection. To consider the mechanisms of this extreme diurnal variation, we examined biochemical studies and concluded that the diurnal variation was not caused by the differences in hepatic Cd level, basal hepatic metallothionein (MT) level, and induction level or induction speed of hepatic MT. We suggested that one of the candidate determination factors was glutathione. We believe that the "chronotoxicology" for metal toxicity may be classic, yet new viewpoint in modern toxicology field.

  10. 40 CFR 63.994 - Halogen scrubbers and other halogen reduction devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... halogen scrubber or other halogen reduction technique used to reduce the vent stream halogen atom mass... subpart shall determine the halogen atom mass emission rate prior to the combustion device according to...

  11. 40 CFR 63.994 - Halogen scrubbers and other halogen reduction devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... halogen scrubber or other halogen reduction technique used to reduce the vent stream halogen atom mass... subpart shall determine the halogen atom mass emission rate prior to the combustion device according to...

  12. 40 CFR 63.994 - Halogen scrubbers and other halogen reduction devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... halogen scrubber or other halogen reduction technique used to reduce the vent stream halogen atom mass... subpart shall determine the halogen atom mass emission rate prior to the combustion device according to...

  13. 40 CFR 63.994 - Halogen scrubbers and other halogen reduction devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... halogen scrubber or other halogen reduction technique used to reduce the vent stream halogen atom mass... subpart shall determine the halogen atom mass emission rate prior to the combustion device according to...

  14. 40 CFR 63.994 - Halogen scrubbers and other halogen reduction devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... halogen scrubber or other halogen reduction technique used to reduce the vent stream halogen atom mass... subpart shall determine the halogen atom mass emission rate prior to the combustion device according to...

  15. 40 CFR 61.349 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the unit in accordance with good engineering and safety practices for handling flammable, explosive... device shall be made as soon as practicable but no later than 5 calendar days after detection. Repair...

  16. 40 CFR 61.349 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the unit in accordance with good engineering and safety practices for handling flammable, explosive... device shall be made as soon as practicable but no later than 5 calendar days after detection. Repair...

  17. Nanotube resonator devices

    DOEpatents

    Jensen, Kenneth J; Zettl, Alexander K; Weldon, Jeffrey A

    2014-05-06

    A fully-functional radio receiver fabricated from a single nanotube is being disclosed. Simultaneously, a single nanotube can perform the functions of all major components of a radio: antenna, tunable band-pass filter, amplifier, and demodulator. A DC voltage source, as supplied by a battery, can power the radio. Using carrier waves in the commercially relevant 40-400 MHz range and both frequency and amplitude modulation techniques, successful music and voice reception has been demonstrated. Also disclosed are a radio transmitter and a mass sensor using a nanotube resonator device.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alvarado, Andrew; Attapattu, Jeevake; Zhang, Yi

    Zinc oxide (ZnO) undergoes a pressure-induced structural transition from its normal ambient-pressure wurtzite (WZ) phase to a rocksalt (RS) phase around 10 GPa. A recent experiment shows that the high-pressure RS ZnO phase can be recovered and stabilized at ambient conditions, which raises exciting prospects of expanding the range of properties of ZnO. For a fundamental understanding of the RS ZnO phase, we have performed first-principles calculations to determine its electronic, phonon, and thermodynamic properties at high (20 GPa) and ambient (0 GPa) pressure. Furthermore, we have calculated its electrical and thermal transport properties, which allow an evaluation of itsmore » thermoelectric figure of merit ZT at different temperature and doping levels. Our calculations show that the ambient-pressure RS ZnO phase can reach ZT values of 0.25 to 0.3 under both n-type and p-type doping in a large temperature range of 400 K to 800 K, which is considerably lower than the temperature range of 1400 K to 1600 K where WZ ZnO reaches similar ZT values. Lastly, these results establish RS ZnO as a promising material for thermoelectric devices designed to operate at temperatures desirable for many heat recovery applications.« less

  19. Thermoelectric properties of rocksalt ZnO from first-principles calculations

    DOE PAGES

    Alvarado, Andrew; Attapattu, Jeevake; Zhang, Yi; ...

    2015-10-22

    Zinc oxide (ZnO) undergoes a pressure-induced structural transition from its normal ambient-pressure wurtzite (WZ) phase to a rocksalt (RS) phase around 10 GPa. A recent experiment shows that the high-pressure RS ZnO phase can be recovered and stabilized at ambient conditions, which raises exciting prospects of expanding the range of properties of ZnO. For a fundamental understanding of the RS ZnO phase, we have performed first-principles calculations to determine its electronic, phonon, and thermodynamic properties at high (20 GPa) and ambient (0 GPa) pressure. Furthermore, we have calculated its electrical and thermal transport properties, which allow an evaluation of itsmore » thermoelectric figure of merit ZT at different temperature and doping levels. Our calculations show that the ambient-pressure RS ZnO phase can reach ZT values of 0.25 to 0.3 under both n-type and p-type doping in a large temperature range of 400 K to 800 K, which is considerably lower than the temperature range of 1400 K to 1600 K where WZ ZnO reaches similar ZT values. Lastly, these results establish RS ZnO as a promising material for thermoelectric devices designed to operate at temperatures desirable for many heat recovery applications.« less

  20. 40 CFR 63.172 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Enclosed combustion devices shall be designed and operated to reduce the organic hazardous air pollutant... non-diverting position with a car-seal or a lock-and-key type configuration. A visual inspection of...

  1. 40 CFR 63.172 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Enclosed combustion devices shall be designed and operated to reduce the organic hazardous air pollutant... non-diverting position with a car-seal or a lock-and-key type configuration. A visual inspection of...

  2. Enhanced thermoelectric efficiency via orthogonal electrical and thermal conductances in phosphorene.

    PubMed

    Fei, Ruixiang; Faghaninia, Alireza; Soklaski, Ryan; Yan, Jia-An; Lo, Cynthia; Yang, Li

    2014-11-12

    Thermoelectric devices that utilize the Seebeck effect convert heat flow into electrical energy and are highly desirable for the development of portable, solid state, passively powered electronic systems. The conversion efficiencies of such devices are quantified by the dimensionless thermoelectric figure of merit (ZT), which is proportional to the ratio of a device's electrical conductance to its thermal conductance. In this paper, a recently fabricated two-dimensional (2D) semiconductor called phosphorene (monolayer black phosphorus) is assessed for its thermoelectric capabilities. First-principles and model calculations reveal not only that phosphorene possesses a spatially anisotropic electrical conductance, but that its lattice thermal conductance exhibits a pronounced spatial-anisotropy as well. The prominent electrical and thermal conducting directions are orthogonal to one another, enhancing the ratio of these conductances. As a result, ZT may reach the criterion for commercial deployment along the armchair direction of phosphorene at T = 500 K and is close to 1 even at room temperature given moderate doping (∼2 × 10(16) m(-2) or 2 × 10(12) cm(-2)). Ultimately, phosphorene hopefully stands out as an environmentally sound thermoelectric material with unprecedented qualities. Intrinsically, it is a mechanically flexible material that converts heat energy with high efficiency at low temperatures (∼300 K), one whose performance does not require any sophisticated engineering techniques.

  3. 40 CFR 60.107a - Monitoring of emissions and operations for fuel gas combustion devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for fuel gas combustion devices. 60.107a Section 60.107a Protection of Environment ENVIRONMENTAL... Commenced After May 14, 2007 § 60.107a Monitoring of emissions and operations for fuel gas combustion devices. (a) Fuel gas combustion devices subject to SO 2 or H 2 S limit. The owner or operator of a fuel...

  4. 40 CFR 60.107a - Monitoring of emissions and operations for fuel gas combustion devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... for fuel gas combustion devices. 60.107a Section 60.107a Protection of Environment ENVIRONMENTAL... Commenced After May 14, 2007 § 60.107a Monitoring of emissions and operations for fuel gas combustion devices. (a) Fuel gas combustion devices subject to SO 2 or H 2 S limit. The owner or operator of a fuel...

  5. 40 CFR 60.107a - Monitoring of emissions and operations for fuel gas combustion devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for fuel gas combustion devices. 60.107a Section 60.107a Protection of Environment ENVIRONMENTAL... Commenced After May 14, 2007 § 60.107a Monitoring of emissions and operations for fuel gas combustion devices. (a) Fuel gas combustion devices subject to SO 2 or H 2 S limit. The owner or operator of a fuel...

  6. 40 CFR 61.349 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... closed position with a car-seal or a lock-and-key type configuration, a flow indicator is not required... with the following conditions: (i) An enclosed combustion device (e.g., a vapor incinerator, boiler, or...

  7. Electronic cooling using thermoelectric devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zebarjadi, M., E-mail: m.zebarjadi@rutgers.edu; Institute of Advanced Materials, Devices, and Nanotechnology, Rutgers University, Piscataway, New Jersey 08854

    2015-05-18

    Thermoelectric coolers or Peltier coolers are used to pump heat in the opposite direction of the natural heat flux. These coolers have also been proposed for electronic cooling, wherein the aim is to pump heat in the natural heat flux direction and from hot spots to the colder ambient temperature. In this manuscript, we show that for such applications, one needs to use thermoelectric materials with large thermal conductivity and large power factor, instead of the traditionally used high ZT thermoelectric materials. We further show that with the known thermoelectric materials, the active cooling cannot compete with passive cooling, andmore » one needs to explore a new set of materials to provide a cooling solution better than a regular copper heat sink. We propose a set of materials and directions for exploring possible materials candidates suitable for electronic cooling. Finally, to achieve maximum cooling, we propose to use thermoelectric elements as fins attached to copper blocks.« less

  8. Gut microbiota mediates diurnal variation of acetaminophen induced acute liver injury in mice.

    PubMed

    Gong, Shenhai; Lan, Tian; Zeng, Liyan; Luo, Haihua; Yang, Xiaoyu; Li, Na; Chen, Xiaojiao; Liu, Zhanguo; Li, Rui; Win, Sanda; Liu, Shuwen; Zhou, Hongwei; Schnabl, Bernd; Jiang, Yong; Kaplowitz, Neil; Chen, Peng

    2018-07-01

    Acetaminophen (APAP) induced hepatotoxicity is a leading cause of acute liver failure worldwide. It is well established that the liver damage induced by acetaminophen exhibits diurnal variation. However, the detailed mechanism for the hepatotoxic variation is not clear. Herein, we aimed to determine the relative contributions of gut microbiota in modulating the diurnal variation of hepatotoxicity induced by APAP. Male Balb/C mice were treated with or without antibiotics and a single dose of orally administered APAP (300 mg/kg) at ZT0 (when the light is on-start of resting period) and ZT12 (when the light is off-start of active period). In agreement with previous findings, hepatic injury was markedly enhanced at ZT12 compared with ZT0. Interestingly, upon antibiotic treatment, ZT12 displayed a protective effect against APAP hepatotoxicity similar to ZT0. Moreover, mice that received the cecal content from ZT12 showed more severe liver damage than mice that received the cecal content from ZT0. 16S sequencing data revealed significant differences in the cecal content between ZT0 and ZT12 in the compositional level. Furthermore, metabolomic analysis showed that the gut microbial metabolites were also different between ZT0 and ZT12. Specifically, the level of 1-phenyl-1,2-propanedione (PPD) was significantly higher at ZT12 than ZT0. Treatment with PPD alone did not cause obvious liver damage. However, PPD synergistically enhanced APAP-induced hepatic injury in vivo and in vitro. Finally, we found Saccharomyces cerevisiae, which could reduce intestinal PPD levels, was able to markedly alleviate APAP-induced liver damage at ZT12. The gut microbial metabolite PPD was responsible, at least in part, for the diurnal variation of hepatotoxicity induced by APAP by decreasing glutathione levels. Acetaminophen (APAP) induced acute liver failure because of over dose is a leading public health problem. APAP-induced liver injury exhibits diurnal variation, specifically APAP causes

  9. 40 CFR 211.210 - Requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Requirements. 211.210 Section 211.210 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.210 Requirements. ...

  10. 40 CFR 211.210 - Requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Requirements. 211.210 Section 211.210 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.210 Requirements. ...

  11. 40 CFR 211.210 - Requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Requirements. 211.210 Section 211.210 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.210 Requirements. ...

  12. Control of Heat and Charge Transport in Nanostructured Hybrid Materials

    DTIC Science & Technology

    2015-07-21

    measurements in our groups have yielded device ZT values of 0.4 on thermoelectric modules consisting of vertically oriented silicon nanowires . This is... nanowires with aspect ratio’s exceeding 10,000. Temperature differences as high as 800 °C are achievable for both types. The bulk nanostructured...thermal conductivity of the silicon nanostructures. Specifically, experiments on an array of 20 nm diameter vertically oriented silicon nanowires have

  13. 33 CFR 159.126a - Suspended solids test: Type II devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Suspended solids test: Type II... Suspended solids test: Type II devices. During the sewage processing test (§ 159.121) 40 effluent samples... suspended solids in accordance with 40 CFR part 136. The arithmetic mean of the total suspended solids in 38...

  14. 40 CFR Table 3 to Subpart Mmm of... - Monitoring Requirements for Control Devices a

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Carbon adsorber (regenerative) Stream flow monitoring device, and 1. Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s) 1. For each regeneration cycle, record the total regeneration stream mass or volumetric flow. Carbon bed temperature monitoring device 2. Temperature of carbon...

  15. 40 CFR Table 3 to Subpart Mmm of... - Monitoring Requirements for Control Devices a

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Carbon adsorber (regenerative) Stream flow monitoring device, and 1. Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s) 1. For each regeneration cycle, record the total regeneration stream mass or volumetric flow. Carbon bed temperature monitoring device 2. Temperature of carbon...

  16. 40 CFR Table 3 to Subpart Mmm of... - Monitoring Requirements for Control Devices a

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Carbon adsorber (regenerative) Stream flow monitoring device, and 1. Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s) 1. For each regeneration cycle, record the total regeneration stream mass or volumetric flow. Carbon bed temperature monitoring device 2. Temperature of carbon...

  17. 40 CFR Table 4 to Subpart Ggg of... - Monitoring Requirements for Control Devices a

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring device, and 1. Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s) 1. For each regeneration cycle, record the total regeneration stream mass or volumetric flow. Carbon bed temperature monitoring device 2. Temperature of carbon bed after regeneration 2. For each...

  18. 40 CFR Table 4 to Subpart Ggg of... - Monitoring Requirements for Control Devices a

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring device, and 1. Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s) 1. For each regeneration cycle, record the total regeneration stream mass or volumetric flow. Carbon bed temperature monitoring device 2. Temperature of carbon bed after regeneration 2. For each...

  19. 40 CFR Table 4 to Subpart Ggg of... - Monitoring Requirements for Control Devices a

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring device, and 1. Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s) 1. For each regeneration cycle, record the total regeneration stream mass or volumetric flow. Carbon bed temperature monitoring device 2. Temperature of carbon bed after regeneration 2. For each...

  20. 40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... initial air pollution control device inspection? (a) The initial air pollution control device inspection... startup. (b) Within 10 operating days following an air pollution control device inspection, all necessary...

  1. 40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... initial air pollution control device inspection? (a) The initial air pollution control device inspection... startup. (b) Within 10 operating days following an air pollution control device inspection, all necessary...

  2. Differential Regulation of Cell Proliferation and Apoptosis by Melatonin Receptor Subtype-Signaling in the Adult Murine Brain.

    PubMed

    Fredrich, Michaela; Christ, Elmar; Korf, Horst-Werner

    2018-06-27


    Background/Aims: Zeitgeber time (ZT)-dependent changes in cell proliferation and apoptosis are regulated by melatonin receptor (MT)-mediated signaling in the adult hippocampus and hypothalamic-hypophyseal system. There are two G-protein-coupled MT-subtypes, MT1 and MT2. Therefore, the present study examined which MT-subtype is required for regulation of ZT-dependent changes in cell proliferation and/or apoptosis in the adult murine brain and pituitary. Adult melatonin-proficient (C3H) mice with targeted deletion of MT1 (MT1 KO) or MT2 (MT2 KO) were adapted to a 12-hour light, 12-hour dark photoperiod and sacrificed at ZT00, ZT06, ZT12, and ZT18. Immunohistochemistry for Ki67 or activated caspase-3 served to quantify proliferating and apoptotic cells in the hippocampal subgranular zone (SGZ) and granule cell layer, the hypothalamic median eminence (ME), and the hypophyseal pars tuberalis. ZT-dependent changes in cell proliferation were found exclusively in the SGZ and ME of MT1 KO mice, while apoptosis showed no ZT-dependent changes in the regions analyzed, neither in MT1 nor in MT2 KO mice. Comparison with our previous studies in C3H mice with functional MTs and MT1/2 KO mice revealed that MT2-mediated signaling is required and sufficient for ZT-dependent changes in cell proliferation in the SGZ and ME, while ZT-dependent changes in apoptosis require signaling from both MT-subtypes. Our results indicate that generation and timing of ZT-dependent changes in cell proliferation and apoptosis by melatonin require different MT-subtype-constellations and emphasize the importance to shed light on the specific function of each receptor-subtype in different tissues and physiological conditions.
    . ©2018S. Karger AG, Basel.

  3. 40 CFR 157.24 - Exemptions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Exemptions. 157.24 Section 157.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PACKAGING REQUIREMENTS FOR PESTICIDES AND DEVICES Child-Resistant Packaging § 157.24 Exemptions. (a) General exemptions...

  4. 40 CFR 424.14 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 424.14 Section 424.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices...

  5. Opto-mechanical design of small infrared cloud measuring device

    NASA Astrophysics Data System (ADS)

    Zhang, Jiao; Yu, Xun; Tao, Yu; Jiang, Xu

    2018-01-01

    In order to make small infrared cloud measuring device can be well in a wide temperature range and day-night environment, a design idea using catadioptric infrared panoramic imaging optical system and simple mechanical structure for realizing observation clode under all-weather conditions was proposed. Firstly, the optical system of cloud measuring device was designed. An easy-to-use numerical method was proposed to acquire the profile of a catadioptric mirror, which brought the property of equidistance projection and played the most important role in a catadioptric panoramic lens. Secondly, the mechanical structure was studied in detail. Overcoming the limitations of traditional primary mirror support structure, integrative design was used for refractor and mirror support structure. Lastly, temperature adaptability and modes of the mirror support structure were analyzed. Results show that the observation range of the cloud measuring device is wide and the structure is simple, the fundamental frequency of the structure is greater than 100 Hz, the surface precision of the system reflector reaches PV of λ/10 and RMS of λ/40under the load of temperature range - 40 60°C, it can meet the needs of existing meteorological observation.

  6. 40 CFR 62.14441 - When must I inspect my HMIWI equipment and air pollution control devices?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and air pollution control devices? 62.14441 Section 62.14441 Protection of Environment ENVIRONMENTAL... my HMIWI equipment and air pollution control devices? (a) You must inspect your large, medium, small... inspect the air pollution control devices on your large, medium, small or small rural HMIWI by May 13...

  7. 40 CFR 62.14441 - When must I inspect my HMIWI equipment and air pollution control devices?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and air pollution control devices? 62.14441 Section 62.14441 Protection of Environment ENVIRONMENTAL... my HMIWI equipment and air pollution control devices? (a) You must inspect your large, medium, small... inspect the air pollution control devices on your large, medium, small or small rural HMIWI by May 13...

  8. Conformal chemically resistant coatings for microflow devices

    DOEpatents

    Folta, James A.; Zdeblick, Mark

    2003-05-13

    A process for coating the inside surfaces of silicon microflow devices, such as electrophoresis microchannels, with a low-stress, conformal (uniform) silicon nitride film which has the ability to uniformly coat deeply-recessed cavities with, for example, aspect ratios of up to 40:1 or higher. The silicon nitride coating allows extended exposure to caustic solutions. The coating enables a microflow device fabricated in silicon to be resistant to all classes of chemicals: acids, bases, and solvents. The process involves low-pressure (vacuum) chemical vapor deposition. The ultra-low-stress silicon nitride deposition process allows 1-2 .mu.m thick films without cracks, and so enables extended chemical protection of a silicon microflow device against caustics for up to 1 year. Tests have demonstrated the resistance of the films to caustic solutions at both ambient and elevated temperatures to 65.degree. C.

  9. 40 CFR 610.52 - Maintenance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Maintenance. 610.52 Section 610.52 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.52 Maintenance. (a...

  10. 40 CFR 610.20 - General.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false General. 610.20 Section 610.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis § 610.20...

  11. 40 CFR 610.52 - Maintenance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Maintenance. 610.52 Section 610.52 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.52 Maintenance. (a...

  12. 40 CFR 610.20 - General.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false General. 610.20 Section 610.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis § 610.20...

  13. 40 CFR 610.52 - Maintenance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Maintenance. 610.52 Section 610.52 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.52 Maintenance. (a...

  14. 40 CFR 610.52 - Maintenance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Maintenance. 610.52 Section 610.52 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.52 Maintenance. (a...

  15. 40 CFR 610.20 - General.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false General. 610.20 Section 610.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis § 610.20...

  16. 40 CFR 157.34 - Certification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Certification. 157.34 Section 157.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PACKAGING REQUIREMENTS FOR PESTICIDES AND DEVICES Child-Resistant Packaging § 157.34 Certification. (a) General. (1) The...

  17. Control of phonon transport by the formation of the Al2O3 interlayer in Al2O3-ZnO superlattice thin films and their in-plane thermoelectric energy generator performance.

    PubMed

    Park, No-Won; Ahn, Jay-Young; Park, Tae-Hyun; Lee, Jung-Hun; Lee, Won-Yong; Cho, Kwanghee; Yoon, Young-Gui; Choi, Chel-Jong; Park, Jin-Seong; Lee, Sang-Kwon

    2017-06-01

    Recently, significant progress has been made in increasing the figure-of-merit (ZT) of various nanostructured materials, including thin-film and quantum dot superlattice structures. Studies have focused on the size reduction and control of the surface or interface of nanostructured materials since these approaches enhance the thermopower and phonon scattering in quantum and superlattice structures. Currently, bismuth-tellurium-based semiconductor materials are widely employed for thermoelectric (TE) devices such as TE energy generators and coolers, in addition to other sensors, for use at temperatures under 400 K. However, new and promising TE materials with enhanced TE performance, including doped zinc oxide (ZnO) multilayer or superlattice thin films, are also required for designing solid-state TE power generating devices with the maximum output power density and for investigating the physics of in-plane TE generators. Herein, we report the growth of Al 2 O 3 /ZnO (AO/ZnO) superlattice thin films, which were prepared by atomic layer deposition (ALD), and the evaluation of their electrical and TE properties. All the in-plane TE properties, including the Seebeck coefficient (S), electrical conductivity (σ), and thermal conductivity (κ), of the AO/ZnO superlattice (with a 0.82 nm-thick AO layer) and AO/ZnO films (with a 0.13 nm-thick AO layer) were evaluated in the temperature range 40-300 K, and the measured S, σ, and κ were -62.4 and -17.5 μV K -1 , 113 and 847 (Ω cm) -1 , and 0.96 and 1.04 W m -1 K -1 , respectively, at 300 K. Consequently, the in-plane TE ZT factor of AO/ZnO superlattice films was found to be ∼0.014, which is approximately two times more than that of AO/ZnO films (ZT of ∼0.007) at 300 K. Furthermore, the electrical power generation efficiency of the TE energy generator consisting of four couples of n-AO/ZnO superlattice films and p-Bi 0.5 Sb 1.5 Te 3 (p-BST) thin-film legs on the substrate was demonstrated. Surprisingly, the output

  18. 40 CFR 60.18 - General control device and work practice requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... practice requirements. 60.18 Section 60.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 60.18 General control device and work practice requirements. (a) Introduction. (1) This section..., less than 18.3 m/sec (60 ft/sec), except as provided in paragraphs (c)(4) (ii) and (iii) of this...

  19. 40 CFR 60.18 - General control device and work practice requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... practice requirements. 60.18 Section 60.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 60.18 General control device and work practice requirements. (a) Introduction. (1) This section..., less than 18.3 m/sec (60 ft/sec), except as provided in paragraphs (c)(4) (ii) and (iii) of this...

  20. 40 CFR 60.18 - General control device and work practice requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... practice requirements. 60.18 Section 60.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 60.18 General control device and work practice requirements. (a) Introduction. (1) This section..., less than 18.3 m/sec (60 ft/sec), except as provided in paragraphs (c)(4) (ii) and (iii) of this...

  1. 40 CFR 60.18 - General control device and work practice requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... practice requirements. 60.18 Section 60.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 60.18 General control device and work practice requirements. (a) Introduction. (1) This section..., less than 18.3 m/sec (60 ft/sec), except as provided in paragraphs (c)(4) (ii) and (iii) of this...

  2. Device Data Ingestion for Industrial Big Data Platforms with a Case Study †

    PubMed Central

    Ji, Cun; Shao, Qingshi; Sun, Jiao; Liu, Shijun; Pan, Li; Wu, Lei; Yang, Chenglei

    2016-01-01

    Despite having played a significant role in the Industry 4.0 era, the Internet of Things is currently faced with the challenge of how to ingest large-scale heterogeneous and multi-type device data. In response to this problem we present a heterogeneous device data ingestion model for an industrial big data platform. The model includes device templates and four strategies for data synchronization, data slicing, data splitting and data indexing, respectively. We can ingest device data from multiple sources with this heterogeneous device data ingestion model, which has been verified on our industrial big data platform. In addition, we present a case study on device data-based scenario analysis of industrial big data. PMID:26927121

  3. 40 CFR 60.107a - Monitoring of emissions and operations for fuel gas combustion devices and flares.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for fuel gas combustion devices and flares. 60.107a Section 60.107a Protection of Environment... combustion devices and flares. (a) Fuel gas combustion devices subject to SO2 or H2S limit and flares subject to H2S concentration requirements. The owner or operator of a fuel gas combustion device that is...

  4. 40 CFR 60.107a - Monitoring of emissions and operations for fuel gas combustion devices and flares.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for fuel gas combustion devices and flares. 60.107a Section 60.107a Protection of Environment... combustion devices and flares. (a) Fuel gas combustion devices subject to SO2 or H2S limit and flares subject to H2S concentration requirements. The owner or operator of a fuel gas combustion device that is...

  5. Influence of convection at outer ceramic surfaces on the characterization of thermoelectric modules by impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Beltrán-Pitarch, Braulio; García-Cañadas, Jorge

    2018-02-01

    Impedance spectroscopy is a useful method for the characterization of thermoelectric (TE) modules. It can determine with high accuracy the module's dimensionless figure of merit (zT) as well as the average TE properties of the module's thermoelements. Interpretation of impedance results requires the use of a theoretical model (equivalent circuit), which provides the desired device parameters after a fitting is performed to the experimental results. Here, we extend the currently available equivalent circuit, only valid for adiabatic conditions, to account for the effect of convection at the outer surface of the module ceramic plates, which is the part of the device where convection is more prominent. This is performed by solving the heat equation in the frequency domain including convection heat losses. As a result, a new element (convection resistance) appears in the developed equivalent circuit, which starts to influence at mid-low frequencies, causing a decrease of the typically observed semicircle in the impedance spectrum. If this effect is not taken into account, an underestimation of the zT occurs when measurements are performed under room conditions. The theoretical model is validated by experimental measurements performed in a commercial module with and without vacuum. Interestingly, the use of the new equivalent circuit allows the determination of the convection heat transfer coefficient (h), if the module's Seebeck coefficient is known, and an impedance measurement in vacuum is performed, opening up the possibility to develop TE modules as h sensors. On the other hand, if h is known, all the properties of the module (zT, ohmic (internal) resistance, average Seebeck coefficient and average thermal conductivity of the thermoelements and thermal conductivity of the ceramics) can be obtained from one impedance measurement in vacuum and another measurement under room conditions.

  6. 40 CFR 61.349 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emission Standard for Benzene Waste Operations § 61.349 Standards: Closed-vent systems and control devices... efficiency of 95 weight percent or greater, or shall recover or control the benzene emissions vented to it..., or shall recover or control the benzene emissions vented to it with an efficiency of 98 weight...

  7. 40 CFR 61.349 - Standards: Closed-vent systems and control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emission Standard for Benzene Waste Operations § 61.349 Standards: Closed-vent systems and control devices... efficiency of 95 weight percent or greater, or shall recover or control the benzene emissions vented to it..., or shall recover or control the benzene emissions vented to it with an efficiency of 98 weight...

  8. Low-temperature thermoelectric properties of the electron-doped perovskites Sr1- x Ca x Ti1- y Nb y O3

    NASA Astrophysics Data System (ADS)

    Okuda, Tetsuji; Fukuyado, Junichi; Narikiyo, Kurahito; Akaki, Mitsuru; Kuwahara, Hideki

    2013-08-01

    We have investigated the thermoelectric (TE) properties for single crystals of the perovskites Sr1- x Ca x Ti1- y Nb y O3 for 0 ≤ x ≤ 0.4 and 0 ≤ y ≤ 0.03 at temperatures below room temperature (RT). We found that SrTi0.99Nb0.01O3 showed a large power factor at low temperatures ( PF = 50 µW/K2cm at 100 K ˜ 90 µW/K2cm at 50 K) and the largest dimensionless TE figure-ofmerit at temperatures below 40 K ( ZT ˜ 0.07) among the reported materials. Such a large low-temperature TE response around a carrier concentration of 1020 cm-3 is due to a distinct phonon drag effect. We also found that the Ca2+ substitution for Sr2+ increased the ZT at 300 K for Sr1- x Ca x Ti0.97Nb0.03O3 from 0.08 to 0.105. The enhancement of the ZT around RT originates both from a large reduction of a thermal conductivity due to a randomness introduced into the crystal structure and from an unexpected enhancement of a Seebeck coefficient.

  9. 40 CFR 63.782 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...: Add-on control system means an air pollution control device such as a carbon absorber or incinerator... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Definitions. 63.782 Section 63.782 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL...

  10. 40 CFR 63.782 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...: Add-on control system means an air pollution control device such as a carbon absorber or incinerator... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Definitions. 63.782 Section 63.782 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL...

  11. 40 CFR 63.782 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...: Add-on control system means an air pollution control device such as a carbon absorber or incinerator... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Definitions. 63.782 Section 63.782 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL...

  12. 40 CFR 63.782 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...: Add-on control system means an air pollution control device such as a carbon absorber or incinerator... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Definitions. 63.782 Section 63.782 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL...

  13. 40 CFR 610.30 - General.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false General. 610.30 Section 610.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.30 General. (a) If the...

  14. 40 CFR 610.30 - General.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false General. 610.30 Section 610.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.30 General. (a) If the...

  15. 40 CFR 610.30 - General.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false General. 610.30 Section 610.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.30 General. (a) If the...

  16. 40 CFR 610.30 - General.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false General. 610.30 Section 610.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.30 General. (a) If the...

  17. 40 CFR 63.782 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: Add-on control system means an air pollution control device such as a carbon absorber or incinerator... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Definitions. 63.782 Section 63.782 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL...

  18. 40 CFR 610.30 - General.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false General. 610.30 Section 610.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.30 General. (a) If the...

  19. Simultaneous validation of the SunTech CT40 automated blood pressure measurement device by the 1993 British Hypertension Society protocol and the Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2: 2013 standard.

    PubMed

    Polo Friz, Hernan; Punzi, Veronica; Petri, Francesco; Orlandi, Riccardo; Maggiolini, Daniele; Polo Friz, Melisa; Primitz, Laura; Vighi, Giuseppe

    2017-10-01

    This study aimed to perform a simultaneous, third-party, independent validation of the oscillometric SunTech CT40 device for blood pressure (BP) measurement, according to the 1993 protocol of the British Hypertension Society and the standard of the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) 81060-2:2013. Patient recruitment, study procedures, and data analysis followed the recommendations stated by the protocols. The study was approved by the institutional review board. A total of 94 participants were included, 52 (55.3%) women, mean±SD age: 63.1±18.0 years, mean±SD arm circumference: 35.0±9.0 cm. The average of observers' entry BPs was 146.9±37.2 mmHg for systolic blood pressure (SBP) and 82.2±22.1 mmHg for diastolic blood pressure (DBP). Differences between the standard measurement and the test device within 5, 10, and 15 mmHg, for the better observer, were 79.4, 96.5, and 100.0% for SBP and 82.6, 97.5, and 100.0% for DBP, respectively. The mean±SD differences between the readings obtained using the test device and those obtained by the observers (AAMI/ISO 81060-2:2013 standard criterion 1) were 0.3±5.0 mmHg (SBP) and -0.8±4.3 mmHg (DBP), and the mean±SD differences between average of reference readings and average of test device readings in each patient (criterion 2) were 0.3±3.9 and -0.8±3.5 mmHg for SBP and DBP, respectively. The CT40 BP device achieved A/A grade of the British Hypertension Society protocol and fulfilled the requirements (criteria 1 and 2) of the AAMI/ISO standard. CT40 can be recommended for BP measurement in adults.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alvarado, Andrew; Attapattu, Jeevake; Zhang, Yi

    Zinc oxide (ZnO) undergoes a pressure-induced structural transition from its normal ambient-pressure wurtzite (WZ) phase to a rocksalt (RS) phase around 10 GPa. A recent experiment shows that the high-pressure RS ZnO phase can be recovered and stabilized at ambient conditions, which raises exciting prospects of expanding the range of properties of ZnO. For a fundamental understanding of the RS ZnO phase, we have performed first-principles calculations to determine its electronic, phonon, and thermodynamic properties at high (20 GPa) and ambient (0 GPa) pressure. Furthermore, we have calculated its electrical and thermal transport properties, which allow an evaluation of its thermoelectric figure ofmore » merit ZT at different temperature and doping levels. Our calculations show that the ambient-pressure RS ZnO phase can reach ZT values of 0.25 to 0.3 under both n-type and p-type doping in a large temperature range of 400 K to 800 K, which is considerably lower than the temperature range of 1400 K to 1600 K where WZ ZnO reaches similar ZT values. These results establish RS ZnO as a promising material for thermoelectric devices designed to operate at temperatures desirable for many heat recovery applications.« less

  1. The influence of surface functionalization on thermal transport and thermoelectric properties of MXene monolayers.

    PubMed

    Sarikurt, Sevil; Çakır, Deniz; Keçeli, Murat; Sevik, Cem

    2018-05-10

    The newest members of a two-dimensional material family, involving transition metal carbides and nitrides (called MXenes), have garnered increasing attention due to their tunable electronic and thermal properties depending on the chemical composition and functionalization. This flexibility can be exploited to fabricate efficient electrochemical energy storage (batteries) and energy conversion (thermoelectric) devices. In this study, we calculated the Seebeck coefficients and lattice thermal conductivity values of oxygen terminated M2CO2 (where M = Ti, Zr, Hf, Sc) monolayer MXene crystals in two different functionalization configurations (model-II (MD-II) and model-III (MD-III)), using density functional theory and Boltzmann transport theory. We estimated the thermoelectric figure-of-merit, zT, of these materials by two different approaches, as well. First of all, we found that the structural model (i.e. adsorption site of oxygen atom on the surface of MXene) has a paramount impact on the electronic and thermoelectric properties of MXene crystals, which can be exploited to engineer the thermoelectric properties of these materials. The lattice thermal conductivity κl, Seebeck coefficient and zT values may vary by 40% depending on the structural model. The MD-III configuration always has the larger band gap, Seebeck coefficient and zT, and smaller κl as compared to the MD-II structure due to a larger band gap, highly flat valence band and reduced crystal symmetry in the former. The MD-III configuration of Ti2CO2 and Zr2CO2 has the lowest κl as compared to the same configuration of Hf2CO2 and Sc2CO2. Among all the considered structures, the MD-II configuration of Hf2CO2 has the highest κl, and Ti2CO2 and Zr2CO2 in the MD-III configuration have the lowest κl. For instance, while the band gap of the MD-II configuration of Ti2CO2 is 0.26 eV, it becomes 0.69 eV in MD-III. The zTmax value may reach up to 1.1 depending on the structural model of MXene.

  2. 40 CFR 65.141 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Definitions. 65.141 Section 65.141 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65...

  3. 21 CFR 814.40 - Time frames for reviewing a PMA.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES PREMARKET APPROVAL OF MEDICAL DEVICES FDA Action on a PMA § 814.40 Time frames for... the applicant does not submit a major amendment, FDA will review the PMA and, after receiving the report and recommendation of the appropriate FDA advisory committee, send the applicant an approval order...

  4. 21 CFR 814.40 - Time frames for reviewing a PMA.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES PREMARKET APPROVAL OF MEDICAL DEVICES FDA Action on a PMA § 814.40 Time frames for... the applicant does not submit a major amendment, FDA will review the PMA and, after receiving the report and recommendation of the appropriate FDA advisory committee, send the applicant an approval order...

  5. 21 CFR 814.40 - Time frames for reviewing a PMA.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES PREMARKET APPROVAL OF MEDICAL DEVICES FDA Action on a PMA § 814.40 Time frames for... the applicant does not submit a major amendment, FDA will review the PMA and, after receiving the report and recommendation of the appropriate FDA advisory committee, send the applicant an approval order...

  6. 40 CFR 211.207 - Computation of the noise -reduction rating (NRR).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Computation of the noise -reduction... (CONTINUED) NOISE ABATEMENT PROGRAMS PRODUCT NOISE LABELING Hearing Protective Devices § 211.207 Computation of the noise -reduction rating (NRR). Calculate the NRR for hearing protective devices by...

  7. 40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... annual air pollution control device inspection), you must complete the air pollution control device...

  8. 40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... annual air pollution control device inspection), you must complete the air pollution control device...

  9. 40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... annual air pollution control device inspection), you must complete the air pollution control device...

  10. Correlation between defect transition levels and thermoelectric operational temperature of doped CrSi2

    NASA Astrophysics Data System (ADS)

    Singh, Abhishek; Pandey, Tribhuwan

    2014-03-01

    The performance of a thermoelectric material is quantified by figure of merit ZT. The challenge in achieving high ZT value requires simultaneously high thermopower, high electrical conductivity and low thermal conductivity at optimal carrier concentration. So far doping is the most versatile approach used for modifying thermoelectric properties. Previous studies have shown that doping can significantly improve the thermoelectric performance, however the tuning the operating temperature of a thermoelectric device is a main issue. Using first principles density functional theory, we report for CrSi2, a linear relationship between thermodynamic charge state transition levels of defects and temperature at which thermopower peaks. We show for doped CrSi2 that the peak of thermopower occurs at the temperature Tm, which corresponds to the position of defect transition level. Therefore, by modifying the defect transition level, a thermoelectric material with a given operational temperature can be designed. The authors thankfully acknowledge support from ADA under NpMASS.

  11. High thermoelectric performance of graphite nanofibers.

    PubMed

    Tran, Van-Truong; Saint-Martin, Jérôme; Dollfus, Philippe; Volz, Sebastian

    2018-02-22

    Graphite nanofibers (GNFs) have been demonstrated to be a promising material for hydrogen storage and heat management in electronic devices. Here, by means of first-principles and transport simulations, we show that GNFs can also be an excellent material for thermoelectric applications thanks to the interlayer weak van der Waals interaction that induces low thermal conductance and a step-like shape in the electronic transmission with mini-gaps, which are necessary ingredients to achieve high thermoelectric performance. This study unveils that the platelet form of GNFs in which graphite layers are perpendicular to the fiber axis can exhibit outstanding thermoelectric properties with a figure of merit ZT reaching 3.55 in a 0.5 nm diameter fiber and 1.1 in a 1.1 nm diameter one. Interestingly, by introducing 14 C isotope doping, ZT can even be enhanced up to more than 5, and more than 8 if we include the effect of finite phonon mean free path, which demonstrates the amazing thermoelectric potential of GNFs.

  12. Significant enhancement in thermoelectric performance of nanostructured higher manganese silicides synthesized employing a melt spinning technique.

    PubMed

    Muthiah, Saravanan; Singh, R C; Pathak, B D; Avasthi, Piyush Kumar; Kumar, Rishikesh; Kumar, Anil; Srivastava, A K; Dhar, Ajay

    2018-01-25

    The limited thermoelectric performance of p-type Higher Manganese Silicides (HMS) in terms of their low figure-of-merit (ZT), which is far below unity, is the main bottle-neck for realising an efficient HMS based thermoelectric generator, which has been recognized as the most promising material for harnessing waste-heat in the mid-temperature range, owing to its thermal stability, earth-abundant and environmentally friendly nature of its constituent elements. We report a significant enhancement in the thermoelectric performance of nanostructured HMS synthesized using rapid solidification by optimizing the cooling rates during melt-spinning followed by spark plasma sintering of the resulting melt-spun ribbons. By employing this experimental strategy, an unprecedented ZT ∼ 0.82 at 800 K was realized in spark plasma sintered 5 at% Al-doped MnSi 1.73 HMS, melt spun at an optimized high cooling rate of ∼2 × 10 7 K s -1 . This enhancement in ZT represents a ∼25% increase over the best reported values thus far for HMS and primarily originates from a nano-crystalline microstructure consisting of a HMS matrix (20-40 nm) with excess Si (3-9 nm) uniformly distributed in it. This nanostructure, resulting from the high cooling rates employed during the melt-spinning of HMS, introduces a high density of nano-crystallite boundaries in a wide spectrum of nano-scale dimensions, which scatter the low-to-mid-wavelength heat-carrying phonons. This abundant phonon scattering results in a significantly reduced thermal conductivity of ∼1.5 W m -1 K -1 at 800 K, which primarily contributes to the enhancement in ZT.

  13. 40 CFR 281.33 - Release detection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... corrosion and equipped with both spill and overfill prevention devices) may temporarily use monthly... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Release detection. 281.33 Section 281.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED...

  14. 40 CFR 281.33 - Release detection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... corrosion and equipped with both spill and overfill prevention devices) may temporarily use monthly... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Release detection. 281.33 Section 281.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED...

  15. 40 CFR 610.16 - Applicant's responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicant's responsibilities. 610.16 Section 610.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL... device covered by the application, including drawings, schematics and information on the theory of...

  16. 40 CFR 63.1029 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation systems..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and... in heavy liquid service; pressure relief devices in light liquid or heavy liquid service; and...

  17. 40 CFR 63.1029 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation systems..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and... in heavy liquid service; pressure relief devices in light liquid or heavy liquid service; and...

  18. 40 CFR 63.1010 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation systems..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and... heavy liquid service; pressure relief devices in light liquid or heavy liquid service; and...

  19. 40 CFR 63.1029 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation systems..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and... in heavy liquid service; pressure relief devices in light liquid or heavy liquid service; and...

  20. 40 CFR 63.1029 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation systems..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and... in heavy liquid service; pressure relief devices in light liquid or heavy liquid service; and...

  1. 40 CFR 63.1010 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation systems..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and... heavy liquid service; pressure relief devices in light liquid or heavy liquid service; and...

  2. 40 CFR 63.1010 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation systems..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and... heavy liquid service; pressure relief devices in light liquid or heavy liquid service; and...

  3. 40 CFR 63.1010 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation systems..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and... heavy liquid service; pressure relief devices in light liquid or heavy liquid service; and...

  4. 40 CFR 63.1029 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation systems..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and... in heavy liquid service; pressure relief devices in light liquid or heavy liquid service; and...

  5. 40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... pollution control device inspection? (a) The initial air pollution control device inspection must be... meeting the amended emission limitations. (b) Within 10 operating days following an air pollution control...

  6. 40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... pollution control device inspection? (a) The initial air pollution control device inspection must be... meeting the amended emission limitations. (b) Within 10 operating days following an air pollution control...

  7. 40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... pollution control device inspection? (a) The initial air pollution control device inspection must be... meeting the amended emission limitations. (b) Within 10 operating days following an air pollution control...

  8. 40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control device inspection), you must complete the air pollution control...

  9. 40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control device inspection), you must complete the air pollution control...

  10. Synthesis of the graphene-ZnTiO3 nanocomposite for solar light assisted photodegradation of methylene blue

    NASA Astrophysics Data System (ADS)

    Gayathri, Shunmugiah; Jayabal, Palanisamy; Kottaisamy, Muniasamy; Ramakrishnan, Veerabahu

    2015-10-01

    Cubic and hexagonal phase zinc titanate (ZT) nanoparticles were synthesized via simple chemical precipitation method. The graphene-zinc titanate (GZT) nanocomposites were prepared by using the synthesized ZT nanoparticles and graphene oxide as precursors. The synthesized materials were characterized by various spectroscopic techniques. The agglomerated ZT nanoparticles anchored on graphene sheets are clearly visible in the field emission scanning electron micrograph (FE-SEM) image. Raman mapping of the GZT nanocomposites revealed the homogeneity and distribution of ZT nanoparticles on the surface of graphene. The UV-visible absorption and photoluminescence spectra of the samples suggest that the GZT nanocomposites can be used as efficient photocatalysts to remove organic dye from water. The photocatalytic activity of the synthesized photocatalysts was evaluated by the photodegradation of methylene blue dye under sunlight irradiation. The enhanced absorption in the visible region of the GZT samples compared to the ZT samples played a vital role during the photocatalysis. The hexagonal phase GZT nanocomposite displayed remarkable photocatalytic activity compared to the bare ZT nanoparticles. The possible electron transfer mechanism for graphene-ZT interface during the photocatalysis process is also proposed. Furthermore, the reusability and stability tests for the prepared photocatalysts were made and reported.

  11. 40 CFR 63.4981 - What definitions apply to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subpart are defined in the CAA, in 40 CFR 63.2, and in this section as follows: Add-on control means an air pollution control device such as a thermal oxidizer or carbon adsorber that reduces pollution in... those emissions into an add-on air pollution control device. Capture efficiency or capture system...

  12. 40 CFR 63.4981 - What definitions apply to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subpart are defined in the CAA, in 40 CFR 63.2, and in this section as follows: Add-on control means an air pollution control device such as a thermal oxidizer or carbon adsorber that reduces pollution in... those emissions into an add-on air pollution control device. Capture efficiency or capture system...

  13. 40 CFR 63.4981 - What definitions apply to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subpart are defined in the CAA, in 40 CFR 63.2, and in this section as follows: Add-on control means an air pollution control device such as a thermal oxidizer or carbon adsorber that reduces pollution in... those emissions into an add-on air pollution control device. Capture efficiency or capture system...

  14. 27 CFR 478.153 - Semiautomatic assault weapons and large capacity ammunition feeding devices manufactured or...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... weapons and large capacity ammunition feeding devices manufactured or imported for the purposes of testing... AMMUNITION Exemptions, Seizures, and Forfeitures § 478.153 Semiautomatic assault weapons and large capacity... weapon, and § 478.40a with respect to large capacity ammunition feeding devices, shall not apply to the...

  15. 27 CFR 478.153 - Semiautomatic assault weapons and large capacity ammunition feeding devices manufactured or...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... weapons and large capacity ammunition feeding devices manufactured or imported for the purposes of testing... AMMUNITION Exemptions, Seizures, and Forfeitures § 478.153 Semiautomatic assault weapons and large capacity... weapon, and § 478.40a with respect to large capacity ammunition feeding devices, shall not apply to the...

  16. 27 CFR 478.153 - Semiautomatic assault weapons and large capacity ammunition feeding devices manufactured or...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... weapons and large capacity ammunition feeding devices manufactured or imported for the purposes of testing... AMMUNITION Exemptions, Seizures, and Forfeitures § 478.153 Semiautomatic assault weapons and large capacity... weapon, and § 478.40a with respect to large capacity ammunition feeding devices, shall not apply to the...

  17. 27 CFR 478.153 - Semiautomatic assault weapons and large capacity ammunition feeding devices manufactured or...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... weapons and large capacity ammunition feeding devices manufactured or imported for the purposes of testing... AMMUNITION Exemptions, Seizures, and Forfeitures § 478.153 Semiautomatic assault weapons and large capacity... weapon, and § 478.40a with respect to large capacity ammunition feeding devices, shall not apply to the...

  18. 27 CFR 478.153 - Semiautomatic assault weapons and large capacity ammunition feeding devices manufactured or...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... weapons and large capacity ammunition feeding devices manufactured or imported for the purposes of testing... AMMUNITION Exemptions, Seizures, and Forfeitures § 478.153 Semiautomatic assault weapons and large capacity... weapon, and § 478.40a with respect to large capacity ammunition feeding devices, shall not apply to the...

  19. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  20. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  1. 40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment... Requirements § 60.2716 By what date must I conduct the annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control device...

  2. 40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... Compliance Requirements § 60.2141 By what date must I conduct the initial air pollution control device inspection? (a) The initial air pollution control device inspection must be conducted within 60 days after...

  3. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  4. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  5. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  6. 40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... Compliance Requirements § 60.2141 By what date must I conduct the initial air pollution control device inspection? (a) The initial air pollution control device inspection must be conducted within 60 days after...

  7. Optimal Bandwidth for High Efficiency Thermoelectrics

    NASA Astrophysics Data System (ADS)

    Zhou, Jun; Yang, Ronggui; Chen, Gang; Dresselhaus, Mildred S.

    2011-11-01

    The thermoelectric figure of merit (ZT) in narrow conduction bands of different material dimensionalities is investigated for different carrier scattering models. When the bandwidth is zero, the transport distribution function (TDF) is finite, not infinite as previously speculated by Mahan and Sofo [Proc. Natl. Acad. Sci. U.S.A. 93, 7436 (1996)PNASA60027-842410.1073/pnas.93.15.7436], even though the carrier density of states goes to infinity. Such a finite TDF results in a zero electrical conductivity and thus a zero ZT. We point out that the optimal ZT cannot be found in an extremely narrow conduction band. The existence of an optimal bandwidth for a maximal ZT depends strongly on the scattering models and the dimensionality of the material. A nonzero optimal bandwidth for maximizing ZT also depends on the lattice thermal conductivity. A larger maximum ZT can be obtained for materials with a smaller lattice thermal conductivity.

  8. 40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... Requirements § 60.2706 By what date must I conduct the initial air pollution control device inspection? (a) The initial air pollution control device inspection must be conducted within 60 days after installation of the...

  9. 40 CFR 610.12 - Program initiative.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Program initiative. 610.12 Section 610.12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.12 Program initiative. A...

  10. 40 CFR 610.13 - Program structure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Program structure. 610.13 Section 610.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.13 Program structure. (a...

  11. 40 CFR 610.50 - Test configurations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Test configurations. 610.50 Section 610.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.50 Test...

  12. 40 CFR 610.12 - Program initiative.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Program initiative. 610.12 Section 610.12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.12 Program initiative. A...

  13. 40 CFR 610.12 - Program initiative.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Program initiative. 610.12 Section 610.12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.12 Program initiative. A...

  14. 40 CFR 610.13 - Program structure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Program structure. 610.13 Section 610.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.13 Program structure. (a...

  15. 40 CFR 610.12 - Program initiative.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Program initiative. 610.12 Section 610.12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.12 Program initiative. A...

  16. 40 CFR 610.13 - Program structure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Program structure. 610.13 Section 610.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.13 Program structure. (a...

  17. 40 CFR 610.17 - Application format.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Application format. 610.17 Section 610.17 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.17 Application format. (a...

  18. 40 CFR 610.41 - Test configurations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Test configurations. 610.41 Section 610.41 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Vehicle Test Procedures § 610.41...

  19. 40 CFR 610.13 - Program structure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Program structure. 610.13 Section 610.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.13 Program structure. (a...

  20. 40 CFR 610.17 - Application format.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Application format. 610.17 Section 610.17 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.17 Application format. (a...

  1. 40 CFR 610.17 - Application format.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Application format. 610.17 Section 610.17 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.17 Application format. (a...

  2. 40 CFR 610.62 - Driveability tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Driveability tests. 610.62 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.62 Driveability tests. Driveability assessment (at normal ambient temperatures) of the baseline configuration, of the...

  3. 40 CFR 610.62 - Driveability tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Driveability tests. 610.62 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.62 Driveability tests. Driveability assessment (at normal ambient temperatures) of the baseline configuration, of the...

  4. 40 CFR 610.62 - Driveability tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Driveability tests. 610.62 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.62 Driveability tests. Driveability assessment (at normal ambient temperatures) of the baseline configuration, of the...

  5. 40 CFR 610.62 - Driveability tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Driveability tests. 610.62 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.62 Driveability tests. Driveability assessment (at normal ambient temperatures) of the baseline configuration, of the...

  6. 40 CFR 156.159 - Compliance date.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Compliance date. 156.159 Section 156.159 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS LABELING REQUIREMENTS FOR PESTICIDES AND DEVICES Container Labeling § 156.159 Compliance date. Any pesticide product...

  7. 40 CFR 157.27 - Unit packaging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Unit packaging. 157.27 Section 157.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PACKAGING REQUIREMENTS FOR PESTICIDES AND DEVICES Child-Resistant Packaging § 157.27 Unit packaging. Pesticide products...

  8. Portable hand hold device

    NASA Technical Reports Server (NTRS)

    Redmon, Jr., John W. (Inventor); McQueen, Donald H. (Inventor); Sanders, Fred G. (Inventor)

    1990-01-01

    A hand hold device (A) includes a housing (10) having a hand hold (14) and clamping brackets (32,34) for grasping and handling an object. A drive includes drive lever (23), spur gear (22), and rack gears (24,26) carried on rods (24a, 26a) for moving the clamping brackets. A lock includes ratchet gear (40) and pawl (42) biased between lock and unlock positions by a cantilever spring (46,48) and moved by handle (54). Compliant grip pads (32b, 34b) provide compliance to lock, unlock, and hold an object between the clamp brackets.

  9. 40 CFR 63.4981 - What definitions apply to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... defined in the CAA, in 40 CFR 63.2, and in this section as follows: Add-on control means an air pollution control device such as a thermal oxidizer or carbon adsorber that reduces pollution in an air stream by... add-on air pollution control device. Capture efficiency or capture system efficiency means the portion...

  10. Optical interconnection for a polymeric PLC device using simple positional alignment.

    PubMed

    Ryu, Jin Hwa; Kim, Po Jin; Cho, Cheon Soo; Lee, El-Hang; Kim, Chang-Seok; Jeong, Myung Yung

    2011-04-25

    This study proposes a simple cost-effective method of optical interconnection between a planar lightwave circuit (PLC) device chip and an optical fiber. It was conducted to minimize and overcome the coupling loss caused by lateral offset which is due to the process tolerance and the dimensional limitation existing between PLC device chips and fiber array blocks with groove structures. A PLC device chip and a fiber array block were simultaneously fabricated in a series of polymer replication processes using the original master. The dimensions (i.e., width and thickness) of the under-clad of the PLC device chip were identical to those of the fiber array block. The PLC device chip and optical fiber were aligned by simple positional control for the vertical direction of the PLC device chip under a particular condition. The insertion loss of the proposed 1 x 2 multimode optical splitter device interconnection was 4.0 dB at 850 nm and the coupling loss was below 0.1 dB compared with single-fiber based active alignment.

  11. 40 CFR 65.156 - General monitoring requirements for control and recovery devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.156 General monitoring requirements for... systems. (1) All monitoring equipment shall be installed, calibrated, maintained, and operated according...

  12. 40 CFR 265.1054 - Standards: Pressure relief devices in gas/vapor service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... gas/vapor service. 265.1054 Section 265.1054 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... TREATMENT, STORAGE, AND DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 265.1054 Standards: Pressure relief devices in gas/vapor service. (a) Except during pressure releases, each pressure relief...

  13. 40 CFR 63.986 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equipment leaks only. 63.986 Section 63.986 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... leaks only. (a) Equipment and operating requirements. (1) Owners or operators using a nonflare control device to meet the applicable requirements of a referencing subpart for equipment leaks shall meet the...

  14. Image degradation by glare in radiologic display devices

    NASA Astrophysics Data System (ADS)

    Badano, Aldo; Flynn, Michael J.

    1997-05-01

    No electronic devices are currently available that can display digital radiographs without loss of visual information compared to traditional transilluminated film. Light scattering within the glass faceplate of cathode-ray tube (CRT) devices causes excessive glare that reduces image contrast. This glare, along with ambient light reflection, has been recognized as a significant limitation for radiologic applications. Efforts to control the effect of glare and ambient light reflection in CRTs include the use of absorptive glass and thin film coatings. In the near future, flat panel displays (FPD) with thin emissive structures should provide very low glare, high performance devices. We have used an optical Monte Carlo simulation to evaluate the effect of glare on image quality for typical CRT and flat panel display devices. The trade-off between display brightness and image contrast is described. For CRT systems, achieving good glare ratio requires a reduction of brightness to 30-40 percent of the maximum potential brightness. For FPD systems, similar glare performance can be achieved while maintaining 80 percent of the maximum potential brightness.

  15. Thermoelectric properties of sintered type-II clathrates (K, Ba)24(Ga, Sn)136 with various carrier concentrations

    NASA Astrophysics Data System (ADS)

    Kishimoto, Kengo; Koda, Shota; Akai, Koji; Koyanagi, Tsuyoshi

    2015-09-01

    We reported the thermoelectric properties of the sintered type-II clathrate K8Ba16Ga40Sn96 in a previous paper [S. Koda et al., J. Appl. Phys. 116, 023710 (2014)]. The clathrate had a high dimensionless figure of merit ZT, namely, 0.93. In this study, we optimized the carrier concentration n by modifying the chemical compositions of (K, Ba)24(Ga, Sn)136 samples, and heat treated the sintered samples. The carrier mobilities μ were improved because of the reduction in potential barrier scattering at grain boundaries. The room-temperature (RT) n values varied from 7.7 × 1017 to 3.7 × 1019 cm-3; the maximum RT μ value was 170 cm2V-1s-1. Consequently, we obtained a high ZT value of 1.19 at 630 K for n = 2.5 × 1019 cm-3. This material therefore has good thermoelectric properties.

  16. Mobile Device Accuracy for Step Counting Across Age Groups

    PubMed Central

    Guo, Yi; Bian, Jiang; Gurka, Matthew J; Parish, Alice; Smith, Megan D; Lee, Alexandra M; Buford, Thomas W

    2017-01-01

    Background Only one in five American meets the physical activity recommendations of the Department of Health and Human Services. The proliferation of wearable devices and smartphones for physical activity tracking has led to an increasing number of interventions designed to facilitate regular physical activity, in particular to address the obesity epidemic, but also for cardiovascular disease patients, cancer survivors, and older adults. However, the inconsistent findings pertaining to the accuracy of wearable devices for step counting needs to be addressed, as well as factors known to affect gait (and thus potentially impact accuracy) such as age, body mass index (BMI), or leading arm. Objective We aim to assess the accuracy of recent mobile devices for counting steps, across three different age groups. Methods We recruited 60 participants in three age groups: 18-39 years, 40-64 years, and 65-84 years, who completed two separate 1000 step walks on a treadmill at a self-selected speed between 2 and 3 miles per hour. We tested two smartphones attached on each side of the waist, and five wrist-based devices worn on both wrists (2 devices on one wrist and 3 devices on the other), as well as the Actigraph wGT3X-BT, and swapped sides between each walk. All devices were swapped dominant-to-nondominant side and vice-versa between the two 1000 step walks. The number of steps was recorded with a tally counter. Age, sex, height, weight, and dominant hand were self-reported by each participant. Results Among the 60 participants, 36 were female (60%) and 54 were right-handed (90%). Median age was 53 years (min=19, max=83), median BMI was 24.1 (min=18.4, max=39.6). There was no significant difference in left- and right-hand step counts by device. Our analyses show that the Fitbit Surge significantly undercounted steps across all age groups. Samsung Gear S2 significantly undercounted steps only for participants among the 40-64 year age group. Finally, the Nexus 6P significantly

  17. Novel burn device for rapid, reproducible burn wound generation.

    PubMed

    Kim, J Y; Dunham, D M; Supp, D M; Sen, C K; Powell, H M

    2016-03-01

    Scarring following full thickness burns leads to significant reductions in range of motion and quality of life for burn patients. To effectively study scar development and the efficacy of anti-scarring treatments in a large animal model (female red Duroc pigs), reproducible, uniform, full-thickness, burn wounds are needed to reduce variability in observed results that occur with burn depth. Prior studies have proposed that initial temperature of the burner, contact time with skin, thermal capacity of burner material, and the amount of pressure applied to the skin need to be strictly controlled to ensure reproducibility. The purpose of this study was to develop a new burner that enables temperature and pressure to be digitally controlled and monitored in real-time throughout burn wound creation and compare it to a standard burn device. A custom burn device was manufactured with an electrically heated burn stylus and a temperature control feedback loop via an electronic microstat. Pressure monitoring was controlled by incorporation of a digital scale into the device, which measured downward force. The standard device was comprised of a heat resistant handle with a long rod connected to the burn stylus, which was heated using a hot plate. To quantify skin surface temperature and internal stylus temperature as a function of contact time, the burners were heated to the target temperature (200±5°C) and pressed into the skin for 40s to create the thermal injuries. Time to reach target temperature and elapsed time between burns were recorded. In addition, each unit was evaluated for reproducibility within and across three independent users by generating burn wounds at contact times spanning from 5 to 40s at a constant pressure and at pressures of 1 or 3lbs with a constant contact time of 40s. Biopsies were collected for histological analysis and burn depth quantification using digital image analysis (ImageJ). The custom burn device maintained both its internal

  18. Novel burn device for rapid, reproducible burn wound generation

    PubMed Central

    Kim, J.Y.; Dunham, D.M.; Supp, D.M.; Sen, C.K.; Powell, H.M.

    2016-01-01

    Introduction Scarring following full thickness burns leads to significant reductions in range of motion and quality of life for burn patients. To effectively study scar development and the efficacy of anti-scarring treatments in a large animal model (female red Duroc pigs), reproducible, uniform, full-thickness, burn wounds are needed to reduce variability in observed results that occur with burn depth. Prior studies have proposed that initial temperature of the burner, contact time with skin, thermal capacity of burner material, and the amount of pressure applied to the skin need to be strictly controlled to ensure reproducibility. The purpose of this study was to develop a new burner that enables temperature and pressure to be digitally controlled and monitored in real-time throughout burn wound creation and compare it to a standard burn device. Methods A custom burn device was manufactured with an electrically heated burn stylus and a temperature control feedback loop via an electronic microstat. Pressure monitoring was controlled by incorporation of a digital scale into the device, which measured downward force. The standard device was comprised of a heat resistant handle with a long rod connected to the burn stylus, which was heated using a hot plate. To quantify skin surface temperature and internal stylus temperature as a function of contact time, the burners were heated to the target temperature (200 ± 5 °C) and pressed into the skin for 40 s to create the thermal injuries. Time to reach target temperature and elapsed time between burns were recorded. In addition, each unit was evaluated for reproducibility within and across three independent users by generating burn wounds at contact times spanning from 5 to 40 s at a constant pressure and at pressures of 1 or 3 lbs with a constant contact time of 40 s. Biopsies were collected for histological analysis and burn depth quantification using digital image analysis (ImageJ). Results The custom burn device

  19. 40 CFR 610.33 - Durability tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... applied. After identification of a potential failure mode, durability tests may be conducted to... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Durability tests. 610.33 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.33 Durability...

  20. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  1. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  2. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  3. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  4. 40 CFR 63.1258 - Monitoring Requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Monitoring Requirements. 63.1258... Standards for Pharmaceuticals Production § 63.1258 Monitoring Requirements. (a) The owner or operator of any... device design shall be used to establish the operating parameter level. (b) Monitoring for control...

  5. Safety and efficacy of the Aperio thrombectomy device when compared to the Solitaire AB/FR and the Revive devices in a pulsatile flow system.

    PubMed

    Saleh, Mahdi; Spence, John Nathan; Nayak, Sanjeev; Pearce, Gillian; Tennuci, Christopher; Roffe, Christine

    2012-01-01

    There are a limited number of studies comparing the Aperio mechanical thrombectomy device to other stent-based devices. In this paper, we compared the Aperio thrombectomy device to the Solitaire AB, FR and Revive devices in a model of the middle cerebral artery (MCA) within a modified pulsatile flow system. Thrombi made of lamb's blood were placed into a pulsatile flow system perfused with Hartmann's solution at 80 bpm with a mean pressure of 90 mm Hg. 30 experiments were run with each device. Recanalization rates were similar for all three devices (90% with the Solitaire AB, FR, 80% with the Revive, and 90% with the Aperio). The mean number of attempts to retrieve the thrombus was also similar for all three devices (1.7 with the Solitaire AB, FR, 2.1 with the Revive, 1.6 with the Aperio). Clot fragmentation and embolization rates revealed no statistical significance but there was a trend towards lower embolization rates with the Aperio (23% compared to 40% with the Solitaire AB, FR and 47% with the Revive). The Aperio was the fastest to recanalize the MCA (mean of 66 seconds compared to 186 seconds for the Solitaire AB, FR and 169 seconds for the Revive). In this in vitro setting, the Aperio device seems to be an efficacious and safe device when compared to other similar clinically used mechanical thrombectomy devices. Larger clinical trials are warranted.

  6. Safety and efficacy of the Aperio thrombectomy device when compared to the Solitaire AB/FR and the Revive devices in a pulsatile flow system

    PubMed Central

    Saleh, Mahdi; Spence, John Nathan; Nayak, Sanjeev; Pearce, Gillian; Tennuci, Christopher; Roffe, Christine

    2012-01-01

    Background and Purpose: There are a limited number of studies comparing the Aperio mechanical thrombectomy device to other stent-based devices. In this paper, we compared the Aperio thrombectomy device to the Solitaire AB, FR and Revive devices in a model of the middle cerebral artery (MCA) within a modified pulsatile flow system. Methods: Thrombi made of lamb’s blood were placed into a pulsatile flow system perfused with Hartmann’s solution at 80 bpm with a mean pressure of 90 mm Hg. 30 experiments were run with each device. Results: Recanalization rates were similar for all three devices (90% with the Solitaire AB, FR, 80% with the Revive, and 90% with the Aperio). The mean number of attempts to retrieve the thrombus was also similar for all three devices (1.7 with the Solitaire AB, FR, 2.1 with the Revive, 1.6 with the Aperio). Clot fragmentation and embolization rates revealed no statistical significance but there was a trend towards lower embolization rates with the Aperio (23% compared to 40% with the Solitaire AB, FR and 47% with the Revive). The Aperio was the fastest to recanalize the MCA (mean of 66 seconds compared to 186 seconds for the Solitaire AB, FR and 169 seconds for the Revive). Conclusions: In this in vitro setting, the Aperio device seems to be an efficacious and safe device when compared to other similar clinically used mechanical thrombectomy devices. Larger clinical trials are warranted. PMID:23173104

  7. Signal and Noise in FET-Nanopore Devices.

    PubMed

    Parkin, William M; Drndić, Marija

    2018-02-23

    The combination of a nanopore with a local field-effect transistor (FET-nanopore), like a nanoribbon, nanotube, or nanowire, in order to sense single molecules translocating through the pore is promising for DNA sequencing at megahertz bandwidths. Previously, it was experimentally determined that the detection mechanism was due to local potential fluctuations that arise when an analyte enters a nanopore and constricts ion flow through it, rather than the theoretically proposed mechanism of direct charge coupling between the DNA and nanowire. However, there has been little discussion on the experimentally observed detection mechanism and its relation to the operation of real devices. We model the intrinsic signal and noise in such an FET-nanopore device and compare the results to the ionic current signal. The physical dimensions of DNA molecules limit the change in gate voltage on the FET to below 40 mV. We discuss the low-frequency flicker noise (<10 kHz), medium-frequency thermal noise (<100 kHz), and high-frequency capacitive noise (>100 kHz) in FET-nanopore devices. At bandwidths dominated by thermal noise, the signal-to-noise ratio in FET-nanopore devices is lower than in the ionic current signal. At high frequencies, where noise due to parasitic capacitances in the amplifier and chip is the dominant source of noise in ionic current measurements, high-transconductance FET-nanopore devices can outperform ionic current measurements.

  8. 40 CFR 610.12 - Program initiative.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Program initiative. 610.12 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.12 Program initiative. A... being marketed may be inadequate, (b) At the EPA Administrator's initiative, or (c) Upon the application...

  9. 40 CFR 610.50 - Test configurations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Test configurations. 610.50 Section... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.50 Test... the same test sequence for fuel economy and exhaust emissions as specified in subpart D. Subsequently...

  10. 40 CFR 610.50 - Test configurations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Test configurations. 610.50 Section... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.50 Test... the same test sequence for fuel economy and exhaust emissions as specified in subpart D. Subsequently...

  11. 40 CFR 610.50 - Test configurations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Test configurations. 610.50 Section... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.50 Test... the same test sequence for fuel economy and exhaust emissions as specified in subpart D. Subsequently...

  12. 40 CFR 610.50 - Test configurations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Test configurations. 610.50 Section... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.50 Test... the same test sequence for fuel economy and exhaust emissions as specified in subpart D. Subsequently...

  13. Variable ratio regenerative braking device

    DOEpatents

    Hoppie, Lyle O.

    1981-12-15

    Disclosed is a regenerative braking device (10) for an automotive vehicle. The device includes an energy storage assembly (12) having a plurality of rubber rollers (26, 28) mounted for rotation between an input shaft (36) and an output shaft (42), clutches (38, 46) and brakes (40, 48) associated with each shaft, and a continuously variable transmission (22) connectable to a vehicle drivetrain and to the input and output shafts by the respective clutches. The rubber rollers are torsionally stressed to accumulate energy from the vehicle when the input shaft is clutched to the transmission while the brake on the output shaft is applied, and are torsionally relaxed to deliver energy to the vehicle when the output shaft is clutched to the transmission while the brake on the input shaft is applied. The transmission ratio is varied to control the rate of energy accumulation and delivery for a given rotational speed of the vehicle drivetrain.

  14. Thermoelectric efficiency of single-molecule junctions with long molecular linkers.

    PubMed

    Zimbovskaya, Natalya A

    2018-06-18

    We report results of theoretical studies of thermoelectric efficiency of single-molecule junctions with long molecular linkers. The linker is simulated by a chain of identical sites described using a tight-binding model. It is shown that thermoelectric figure of merit ZT strongly depends on the bridge length, being controlled by the lineshape of electron transmission function within the tunnel energy range corresponding to HOMO/LUMO transport channel. Using the adopted model we demonstrate that ZT may significantly increase as the linker lengthens, and that gateway states on the bridge (if any) may noticeably affect the length-dependent ZT. Temperature dependences of ZT for various bridge lengths are analyzed. It is shown that broad minima emerge in ZT versus temperature curves whose positions are controlled by the bridge lengths. © 2018 IOP Publishing Ltd.

  15. 40 CFR 610.23 - Operator interaction effects.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Operator interaction effects. 610.23 Section 610.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...

  16. 40 CFR 610.23 - Operator interaction effects.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Operator interaction effects. 610.23 Section 610.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...

  17. 40 CFR 610.23 - Operator interaction effects.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Operator interaction effects. 610.23 Section 610.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...

  18. 40 CFR 610.23 - Operator interaction effects.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Operator interaction effects. 610.23 Section 610.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...

  19. First-principles study on doping and temperature dependence of thermoelectric property of Bi{sub 2}S{sub 3} thermoelectric material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Donglin; Hu, Chenguo, E-mail: hucg@cqu.edu.cn; Zhang, Cuiling

    2013-05-15

    Graphical abstract: The direction-induced ZT is found. At ZZ direction and n = 1.47 × 10{sup 19} cm{sup −3}, the ZT can reach maximal value, 0.36, which is three times as much as maximal laboratorial value. This result matches well the analysis of electron effective mass. Highlights: ► Electrical transportations of Bi{sub 2}S{sub 3} depend on the concentration and temperature. ► The direction-induced ZT is found. ► At ZZ direction and n = 1.47 × 10{sup 19} cm{sup −3}, the ZT can reach maximal value, 0.36. ► The maximal ZT value is three times as much as maximal laboratorial value.more » ► By doping and temperature tuning, Bi{sub 2}S{sub 3} is a promising thermoelectric material. - Abstract: The electronic structure and thermoelectric property of Bi{sub 2}S{sub 3} are investigated. The electron and hole effective mass of Bi{sub 2}S{sub 3} is analyzed in detail, from which we find that the thermoelectric transportation varies in different directions in Bi{sub 2}S{sub 3} crystal. Along ac plane the higher figure of merit (ZT) could be achieved. For n-type doped Bi{sub 2}S{sub 3}, the optimal doping concentration is found in the range of (1.0–5.0) × 10{sup 19} cm{sup −3}, in which the maximal ZT reaches 0.21 at 900 K, but along ZZ direction, the maximal ZT reaches 0.36. These findings provide a new understanding of thermoelectricity-dependent structure factors and improving ZT ways. The donor concentration N increases as T increases at one bar of pressure under a suitable chemical potential μ, but above this chemical potential μ, the donor concentration N keeps a constant.« less

  20. A conserved fungal glycosyltransferase facilitates pathogenesis of plants by enabling hyphal growth on solid surfaces

    PubMed Central

    Plummer, Amy; Halsey, Kirstie; Lovegrove, Alison; Hammond-Kosack, Kim

    2017-01-01

    Pathogenic fungi must extend filamentous hyphae across solid surfaces to cause diseases of plants. However, the full inventory of genes which support this is incomplete and many may be currently concealed due to their essentiality for the hyphal growth form. During a random T-DNA mutagenesis screen performed on the pleomorphic wheat (Triticum aestivum) pathogen Zymoseptoria tritici, we acquired a mutant unable to extend hyphae specifically when on solid surfaces. In contrast “yeast-like” growth, and all other growth forms, were unaffected. The inability to extend surface hyphae resulted in a complete loss of virulence on plants. The affected gene encoded a predicted type 2 glycosyltransferase (ZtGT2). Analysis of >800 genomes from taxonomically diverse fungi highlighted a generally widespread, but discontinuous, distribution of ZtGT2 orthologues, and a complete absence of any similar proteins in non-filamentous ascomycete yeasts. Deletion mutants of the ZtGT2 orthologue in the taxonomically un-related fungus Fusarium graminearum were also severely impaired in hyphal growth and non-pathogenic on wheat ears. ZtGT2 expression increased during filamentous growth and electron microscopy on deletion mutants (ΔZtGT2) suggested the protein functions to maintain the outermost surface of the fungal cell wall. Despite this, adhesion to leaf surfaces was unaffected in ΔZtGT2 mutants and global RNAseq-based gene expression profiling highlighted that surface-sensing and protein secretion was also largely unaffected. However, ΔZtGT2 mutants constitutively overexpressed several transmembrane and secreted proteins, including an important LysM-domain chitin-binding virulence effector, Zt3LysM. ZtGT2 likely functions in the synthesis of a currently unknown, potentially minor but widespread, extracellular or outer cell wall polysaccharide which plays a key role in facilitating many interactions between plants and fungi by enabling hyphal growth on solid matrices. PMID:29020037

  1. 33 CFR 159.126 - Coliform test: Type II devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... follows: During each of the 10 test days, one sample must be taken at the beginning, middle and end of an 8-consecutive hour period with one additional sample taken immediately following the peak capacity...: Type II devices. (a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent...

  2. 33 CFR 159.123 - Coliform test: Type I devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... as follows: During each of the 10-test days, one sample must be taken at the beginning, middle, and end of an 8-consecutive hour period with one additional sample taken immediately following the peak...: Type I devices. (a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent...

  3. 40 CFR 156.64 - Signal word.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Signal word. 156.64 Section 156.64... REQUIREMENTS FOR PESTICIDES AND DEVICES Human Hazard and Precautionary Statements § 156.64 Signal word. (a... signal word, reflecting the highest Toxicity Category (Category I is the highest toxicity category) to...

  4. 40 CFR 156.64 - Signal word.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Signal word. 156.64 Section 156.64... REQUIREMENTS FOR PESTICIDES AND DEVICES Human Hazard and Precautionary Statements § 156.64 Signal word. (a... signal word, reflecting the highest Toxicity Category (Category I is the highest toxicity category) to...

  5. 40 CFR 156.64 - Signal word.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Signal word. 156.64 Section 156.64... REQUIREMENTS FOR PESTICIDES AND DEVICES Human Hazard and Precautionary Statements § 156.64 Signal word. (a... signal word, reflecting the highest Toxicity Category (Category I is the highest toxicity category) to...

  6. 40 CFR 156.64 - Signal word.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Signal word. 156.64 Section 156.64... REQUIREMENTS FOR PESTICIDES AND DEVICES Human Hazard and Precautionary Statements § 156.64 Signal word. (a... signal word, reflecting the highest Toxicity Category (Category I is the highest toxicity category) to...

  7. 40 CFR 156.64 - Signal word.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Signal word. 156.64 Section 156.64... REQUIREMENTS FOR PESTICIDES AND DEVICES Human Hazard and Precautionary Statements § 156.64 Signal word. (a... signal word, reflecting the highest Toxicity Category (Category I is the highest toxicity category) to...

  8. In vivo evaluation of glucose permeability of an immunoisolation device intended for islet transplantation: a novel application of the microdialysis technique.

    PubMed

    Rafael, E; Wernerson, A; Arner, P; Wu, G S; Tibell, A

    1999-01-01

    Immunoisolation devices consist of semipermeable membranes chosen to protect the islets from the immune system but still allow sufficient passage of nutrients, oxygen, and the therapeutic products, insulin. The exchange between the device and the microcirculation will influence the survival of the graft as well as the metabolic efficacy of the islet implant. Glucose is the important trigger factor for insulin secretion. In this study, we evaluate the in vivo glucose permeability of the Theracyte immunoisolation device at various times after implantation. Empty devices were implanted s.c. in rats. The glucose kinetics in the device was compared to that in the SC tissue during i.v. glucose tolerance tests (IVGTTs), using the microdialysis technique. In rats studied on day 1, or 1, 2, and 4 weeks after implantation, the peak glucose levels (Cmax) were significantly lower, the times-to-peak (TTP) were significantly longer, and the areas under the curve during the first 40 min (AUC(0-40)) were significantly smaller in the device than in the SC fat. However, at 3 months all parameters improved and Cmax, TTP, and AUC(0-40) in the device did not differ significantly from those measured in the SC fat. Thus, during the first 4 weeks the device constitutes a significant diffusion barrier, but at 3 months the exchange between the lumen of devices and the blood stream improves. Our data indicate that implantation of the device several months before transplantation of the cellular graft would improve the exchange across the membrane during the early posttransplant period. This should have positive effects on graft survival and function. We also suggest that microdialysis is a useful tool for evaluating the in vivo performance of macroencapsulation devices.

  9. Validating the Accuracy of Reaction Time Assessment on Computer-Based Tablet Devices.

    PubMed

    Schatz, Philip; Ybarra, Vincent; Leitner, Donald

    2015-08-01

    Computer-based assessment has evolved to tablet-based devices. Despite the availability of tablets and "apps," there is limited research validating their use. We documented timing delays between stimulus presentation and (simulated) touch response on iOS devices (3rd- and 4th-generation Apple iPads) and Android devices (Kindle Fire, Google Nexus, Samsung Galaxy) at response intervals of 100, 250, 500, and 1,000 milliseconds (ms). Results showed significantly greater timing error on Google Nexus and Samsung tablets (81-97 ms), than Kindle Fire and Apple iPads (27-33 ms). Within Apple devices, iOS 7 obtained significantly lower timing error than iOS 6. Simple reaction time (RT) trials (250 ms) on tablet devices represent 12% to 40% error (30-100 ms), depending on the device, which decreases considerably for choice RT trials (3-5% error at 1,000 ms). Results raise implications for using the same device for serial clinical assessment of RT using tablets, as well as the need for calibration of software and hardware. © The Author(s) 2015.

  10. 40 CFR 610.15 - Eligibility for participation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Eligibility for participation. 610.15 Section 610.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.15 Eligibility...

  11. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  12. 40 CFR 610.32 - Test fleet selection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Test fleet selection. 610.32 Section 610.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.32 Test...

  13. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  14. 40 CFR 610.15 - Eligibility for participation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Eligibility for participation. 610.15 Section 610.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.15 Eligibility...

  15. 40 CFR 610.64 - Track test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Track test procedures. 610.64 Section 610.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.64 Track...

  16. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  17. 40 CFR 610.32 - Test fleet selection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Test fleet selection. 610.32 Section 610.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.32 Test...

  18. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  19. 40 CFR 610.34 - Special test conditions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Special test conditions. 610.34 Section 610.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.34...

  20. 40 CFR 610.34 - Special test conditions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Special test conditions. 610.34 Section 610.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.34...

  1. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  2. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  3. 40 CFR 610.32 - Test fleet selection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Test fleet selection. 610.32 Section 610.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.32 Test...

  4. 40 CFR 610.32 - Test fleet selection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Test fleet selection. 610.32 Section 610.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.32 Test...

  5. 40 CFR 610.15 - Eligibility for participation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Eligibility for participation. 610.15 Section 610.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.15 Eligibility...

  6. 40 CFR 610.15 - Eligibility for participation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Eligibility for participation. 610.15 Section 610.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.15 Eligibility...

  7. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  8. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  9. 40 CFR 610.34 - Special test conditions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Special test conditions. 610.34 Section 610.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.34...

  10. 40 CFR 610.32 - Test fleet selection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Test fleet selection. 610.32 Section 610.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.32 Test...

  11. 40 CFR 610.34 - Special test conditions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Special test conditions. 610.34 Section 610.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.34...

  12. 40 CFR 610.51 - Mileage accumulation procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Mileage accumulation procedure. 610.51 Section 610.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.51...

  13. 40 CFR 610.15 - Eligibility for participation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Eligibility for participation. 610.15 Section 610.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.15 Eligibility...

  14. 40 CFR 610.65 - Other test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Other test procedures. 610.65 Section 610.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.65 Other...

  15. Design and Characterization of p-i-n Devices for Betavoltaic Microbatteries on Gallium Nitride

    NASA Astrophysics Data System (ADS)

    Khan, Muhammad Raziuddin A.

    Betavoltaic microbatteries convert nuclear energy released as beta particles directly into electrical energy. These batteries are well suited for electrical applications such as micro-electro-mechanical systems (MEMS), implantable medical devices and sensors. Such devices are often located in hard to access places where long life, micro-size and lightweight are required. The working principle of a betavoltaic device is similar to a photovoltaic device; they differ only in that the electron hole pairs (EHPs) are generated in the device by electrons instead of photons. In this study, the performance of a betavoltaic device fabricated from gallium nitride (GaN) is investigated for beta particle energies equivalent to Tritium (3H) and Nickel-63 (N63) beta sources. GaN is an attractive choice for fabricating betavoltaic devices due to its wide band gap and radiation resistance. Another advantage GaN has is that it can be alloyed with aluminum (Al) to further increase the bandgap, resulting in a higher output power and increased efficiency. Betavoltaic devices were fabricated on p-i-n GaN structures grown by metalorganic chemical vapor deposition (MOCVD). The devices were characterized using current - voltage (IV) measurements without illumination (light or beta), using a laser driven light source, and under an electron beam. Dark IV measurements showed a turn on-voltage of ~ 3.4 V, specific-on-resistance of 15.1 m O-cm2, and a leakage current of 0.5 mA at -- 10 V. A clear photo-response was observed when IV curves were measured for these devices under a light source at a wavelength of 310 nm (4.0 eV). These devices were tested under an electron beam in order to evaluate their behavior as betavoltaic microbatteries without using radioactive materials. Output power of 70 nW and 640 nW with overall efficiencies of 1.2% and 4.0% were determined at the average energy emission of 3H (5.6 keV) and 63N (17 keV) respectively.

  16. Mobile Device Accuracy for Step Counting Across Age Groups.

    PubMed

    Modave, François; Guo, Yi; Bian, Jiang; Gurka, Matthew J; Parish, Alice; Smith, Megan D; Lee, Alexandra M; Buford, Thomas W

    2017-06-28

    Only one in five American meets the physical activity recommendations of the Department of Health and Human Services. The proliferation of wearable devices and smartphones for physical activity tracking has led to an increasing number of interventions designed to facilitate regular physical activity, in particular to address the obesity epidemic, but also for cardiovascular disease patients, cancer survivors, and older adults. However, the inconsistent findings pertaining to the accuracy of wearable devices for step counting needs to be addressed, as well as factors known to affect gait (and thus potentially impact accuracy) such as age, body mass index (BMI), or leading arm. We aim to assess the accuracy of recent mobile devices for counting steps, across three different age groups. We recruited 60 participants in three age groups: 18-39 years, 40-64 years, and 65-84 years, who completed two separate 1000 step walks on a treadmill at a self-selected speed between 2 and 3 miles per hour. We tested two smartphones attached on each side of the waist, and five wrist-based devices worn on both wrists (2 devices on one wrist and 3 devices on the other), as well as the Actigraph wGT3X-BT, and swapped sides between each walk. All devices were swapped dominant-to-nondominant side and vice-versa between the two 1000 step walks. The number of steps was recorded with a tally counter. Age, sex, height, weight, and dominant hand were self-reported by each participant. Among the 60 participants, 36 were female (60%) and 54 were right-handed (90%). Median age was 53 years (min=19, max=83), median BMI was 24.1 (min=18.4, max=39.6). There was no significant difference in left- and right-hand step counts by device. Our analyses show that the Fitbit Surge significantly undercounted steps across all age groups. Samsung Gear S2 significantly undercounted steps only for participants among the 40-64 year age group. Finally, the Nexus 6P significantly undercounted steps for the group

  17. 40 CFR 63.4166 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... device emission destruction or removal efficiency? 63.4166 Section 63.4166 Protection of Environment....4166 How do I determine the add-on control device emission destruction or removal efficiency? (a) For... device organic emissions destruction or removal efficiency, using Equation 2 of this section. ER23JY02...

  18. Heavily Doped PBSE with High Thermoelectric Performance

    NASA Technical Reports Server (NTRS)

    Snyder, G. Jeffrey (Inventor); Wang, Heng (Inventor); Pei, Yanzhong (Inventor)

    2015-01-01

    The present invention discloses heavily doped PbSe with high thermoelectric performance. Thermoelectric property measurements disclosed herein indicated that PbSe is high zT material for mid-to-high temperature thermoelectric applications. At 850 K a peak zT (is) greater than 1.3 was observed when n(sub H) approximately 1.0 X 10(exp 20) cm(exp -3). The present invention also discloses that a number of strategies used to improve zT of PbTe, such as alloying with other elements, nanostructuring and band modification may also be used to further improve zT in PbSe.

  19. 40 CFR Table 4 to Subpart Ooo of... - Operating Parameter Levels

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Operating Parameter Levels 4 Table 4 to..., Table 4 Table 4 to Subpart OOO of Part 63—Operating Parameter Levels Device Parameters to be monitored... concentration level or reading at outlet of device Maximum organic HAP concentration or reading a 25 to 50 mm...

  20. 40 CFR 63.118 - Process vent provisions-periodic reporting and recordkeeping requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... device or other means to achieve and maintain a TRE index value greater than 1.0 but less than 4.0 as... subpart and who elects to demonstrate compliance with the TRE index value greater than 4.0 under § 63.113... § 63.115(e) of this subpart, is made that causes a Group 2 process vent with a TRE greater than 4.0 to...

  1. 40 CFR 63.118 - Process vent provisions-periodic reporting and recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... device or other means to achieve and maintain a TRE index value greater than 1.0 but less than 4.0 as... subpart and who elects to demonstrate compliance with the TRE index value greater than 4.0 under § 63.113... § 63.115(e) of this subpart, is made that causes a Group 2 process vent with a TRE greater than 4.0 to...

  2. 33 CFR 13.01-40 - Miniature medals and bars.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... GENERAL DECORATIONS, MEDALS, RIBBONS AND SIMILAR DEVICES Gold and Silver Lifesaving Medals, Bars, and Miniatures § 13.01-40 Miniature medals and bars. (a) Miniature Gold and Silver Lifesaving Medals and bars are...

  3. 33 CFR 13.01-40 - Miniature medals and bars.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... GENERAL DECORATIONS, MEDALS, RIBBONS AND SIMILAR DEVICES Gold and Silver Lifesaving Medals, Bars, and Miniatures § 13.01-40 Miniature medals and bars. (a) Miniature Gold and Silver Lifesaving Medals and bars are...

  4. 33 CFR 13.01-40 - Miniature medals and bars.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... GENERAL DECORATIONS, MEDALS, RIBBONS AND SIMILAR DEVICES Gold and Silver Lifesaving Medals, Bars, and Miniatures § 13.01-40 Miniature medals and bars. (a) Miniature Gold and Silver Lifesaving Medals and bars are...

  5. 33 CFR 13.01-40 - Miniature medals and bars.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... GENERAL DECORATIONS, MEDALS, RIBBONS AND SIMILAR DEVICES Gold and Silver Lifesaving Medals, Bars, and Miniatures § 13.01-40 Miniature medals and bars. (a) Miniature Gold and Silver Lifesaving Medals and bars are...

  6. 33 CFR 13.01-40 - Miniature medals and bars.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... GENERAL DECORATIONS, MEDALS, RIBBONS AND SIMILAR DEVICES Gold and Silver Lifesaving Medals, Bars, and Miniatures § 13.01-40 Miniature medals and bars. (a) Miniature Gold and Silver Lifesaving Medals and bars are...

  7. Synthesis and characterization of a family of structurally characterized dysprosium alkoxides for improved fatigue-resistance characteristics of PDyZT thin films.

    PubMed

    Boyle, Timothy J; Bunge, Scott D; Clem, Paul G; Richardson, Jacob; Dawley, Jeffrey T; Ottley, Leigh Anna M; Rodriguez, Mark A; Tuttle, Bruce A; Avilucea, Gabriel R; Tissot, Ralph G

    2005-03-07

    Using either an ammoniacal route, the reaction between DyCl3, Na0, and HOR in liquid ammonia, or preferentially reacting Dy(N(SiMe3)2)3 with HOR in a solvent, we isolated a family of dysprosium alkoxides as [Dy(mu-ONep)2(ONep)]4 (1), (ONep)2Dy[(mu3-ONep)(mu-ONep)Dy(ONep)(THF)]2(mu-ONep) (2), (ONep)2Dy[(mu3-ONep)(mu-ONep)Dy(ONep)(py)]2(mu-ONep) (3), [Dy3(mu3-OBut)2(mu-OBut3(OBut)4(HOBut)2] (4), [Dy3(mu3-OBut)2(mu-OBut)3(OBut)4(THF)2] (5), [Dy3(mu3-OBut)2(mu-OBut)3(OBut)4(py)2] (6), (DMP)Dy(mu-DMP)4[Dy(DMP)2(NH3)]2 (7), [Dy(eta6-DMP)(DMP)2]2 (8), Dy(DMP)3(THF)3 (9), Dy(DMP)3(py)3 (10), Dy(DIP)3(NH3)2 (11), [Dy(eta6-DIP)(DIP)2]2 (12), Dy(DIP)3(THF)2 (13), Dy(DIP)3(py)3 (14), Dy(DBP)3(NH3) (15), Dy(DBP)3 (16), Dy(DBP)3(THF) (17), Dy(DBP)3(py)2 (18), [Dy(mu-TPS)(TPS2]2 (19), Dy(TPS)3(THF)3 (20), and Dy(TPS)3(py)3 (21), where ONep = OCH2CMe3, OBut) = OCMe3, DMP = OC6H3(Me)(2)-2,6, DIP = OC6H3(CHMe2)(2)-2,6, DBP = OC6H3(CMe3)(2)-2,6, TPS = OSi(C6H5)3, tol = toluene, THF = tetrahydrofuran, and py = pyridine. We were not able to obtain X-ray quality crystals of compounds 2, 8, and 9. The structures observed and data collected for the Dy compounds are consistent with those reported for its other congeners. A number of these precursors were used as Dy dopants in Pb(Zr0.3Ti0.7)O3 (PZT 30/70) thin films, with compound 12 yielding the highest-quality films. The resulting Pb0.94Dy0.04(Zr0.3Ti0.7)O3 [PDyZT (4/30/70)] had similar properties to PZT (30/70), but showed substantial resistance to polarization reversal fatigue.

  8. Integrated device architectures for electrochromic devices

    DOEpatents

    Frey, Jonathan Mack; Berland, Brian Spencer

    2015-04-21

    This disclosure describes systems and methods for creating monolithically integrated electrochromic devices which may be a flexible electrochromic device. Monolithic integration of thin film electrochromic devices may involve the electrical interconnection of multiple individual electrochromic devices through the creation of specific structures such as conductive pathway or insulating isolation trenches.

  9. 40 CFR 60.195 - Test methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (2) The emission rate (Eb) of total fluorides from anode bake plants shall be computed for each run... groups and at least 4 hours and 3.40 dscm (120 dscf) for anode bake plants. (4) The monitoring devices of...

  10. 40 CFR 60.195 - Test methods and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (2) The emission rate (Eb) of total fluorides from anode bake plants shall be computed for each run... groups and at least 4 hours and 3.40 dscm (120 dscf) for anode bake plants. (4) The monitoring devices of...

  11. 40 CFR 60.195 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (2) The emission rate (Eb) of total fluorides from anode bake plants shall be computed for each run... groups and at least 4 hours and 3.40 dscm (120 dscf) for anode bake plants. (4) The monitoring devices of...

  12. 40 CFR 60.195 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (2) The emission rate (Eb) of total fluorides from anode bake plants shall be computed for each run... groups and at least 4 hours and 3.40 dscm (120 dscf) for anode bake plants. (4) The monitoring devices of...

  13. Humidification performance of two high-flow nasal cannula devices: a bench study.

    PubMed

    Chikata, Yusuke; Izawa, Masayo; Okuda, Nao; Itagaki, Taiga; Nakataki, Emiko; Onodera, Mutsuo; Imanaka, Hideaki; Nishimura, Masaji

    2014-08-01

    Delivering heated and humidified medical gas at 20-60 L/min, high-flow nasal cannula (HFNC) creates low levels of PEEP and ameliorates respiratory mechanics. It has become a common therapy for patients with respiratory failure. However, independent measurement of heat and humidity during HFNC and comparison of HFNC devices are lacking. We evaluated 2 HFNC (Airvo 2 and Optiflow system) devices. Each HFNC was connected to simulated external nares using the manufacturer's standard circuit. The Airvo 2 outlet-chamber temperature was set at 37°C. The Optiflow system incorporated an O2/air blender and a heated humidifier, which was set at 40°C/3. For both systems, HFNC flow was tested at 20, 40, and 50 L/min. Simulating spontaneous breathing using a mechanical ventilator and TTL test lung, we tested tidal volumes (VT) of 300, 500, and 700 mL, and breathing frequencies of 10 and 20 breaths/min. The TTL was connected to the simulated external nares with a standard ventilator circuit. To prevent condensation, the circuit was placed in an incubator maintained at 37°C. Small, medium, and large nasal prongs were tested. Absolute humidity (AH) of inspired gas was measured at the simulated external nares. At 20, 40, and 50 L/min of flow, respective AH values for the Airvo 2 were 35.3 ± 2.0, 37.1 ± 2.2, and 37.6 ± 2.1 mg/L, and for the Optiflow system, 33.1 ± 1.5, 35.9 ± 1.7, and 36.2 ± 1.8 mg/L. AH was lower at 20 L/min of HFNC flow than at 40 and 50 L/min (P < .01). While AH remained constant at 40 and 50 L/min, at 20 L/min of HFNC flow, AH decreased as VT increased for both devices. During bench use of HFNC, AH increased with increasing HFNC flow. When the inspiratory flow of spontaneous breathing exceeded the HFNC flow, AH was influenced by VT. At all experimental settings, AH remained > 30 mg/L.

  14. Incidence, Characteristics, and Clinical Course of Device-Related Thrombus After Watchman Left Atrial Appendage Occlusion Device Implantation in Atrial Fibrillation Patients.

    PubMed

    Kubo, Shunsuke; Mizutani, Yukiko; Meemook, Krissada; Nakajima, Yoshifumi; Hussaini, Asma; Kar, Saibal

    2017-12-11

    This study investigated characteristics and clinical impact of device-related thrombus formation after Watchman device implantation in atrial fibrillation (AF) patients. Left atrial appendage occlusion using the Watchman device is an effective alternative to anticoagulation for stroke prevention in AF patients. However, device-related thrombus formation remains an important concern after Watchman implantation. From 2006 to 2014, 119 consecutive AF patients underwent Watchman implantation. Transesophageal echocardiographic (TEE) follow-up was scheduled at 45 days, at 6 months, and at 12 months after the procedure. The incidence, characteristics, and clinical course of device-related thrombus formation detected by TEE were assessed. Follow-up TEE identified thrombus formation on the Watchman device in 4 patients (3.4%). The prevalence of chronic AF was 100% in patients with thrombus, which was higher than that for patients without thrombus (40.0%). Deployed device size was numerically larger in patients with thrombus (29.3 ± 3.8 mm vs. 25.7 ± 3.2 mm, respectively). All patients with thrombus discontinued any of the anticoagulant/antiplatelet therapy which was required under the study protocol. After restarting or continuing warfarin and aspirin therapy, complete resolution of the thrombus was achieved in all patients at subsequent follow-up TEE. Warfarin therapy was discontinued within 6 months for all cases, and there was no thrombus recurrence. The mean follow-up duration was 1,456 ± 546 days, with no death, stroke, or systemic embolization events in patients with thrombus. AF burden, device size, and anticoagulant/antiplatelet regimens can be associated with device-related thrombus after Watchman device implantation. Short-term warfarin therapy was effective, and the clinical outcomes were favorable. Copyright © 2017 American College of Cardiology Foundation. All rights reserved.

  15. Amine-functionalized mesoporous ZSM-5 zeolite adsorbents for carbon dioxide capture

    NASA Astrophysics Data System (ADS)

    Wang, Yisong; Du, Tao; Song, Yanli; Che, Shuai; Fang, Xin; Zhou, Lifeng

    2017-11-01

    ZSM-5 type zeolite with mesoporous structure was prepared and then amine-functionalized with tetraethylenepentamine (TEPA) by wet impregnation method to form a series of CO2 adsorbents (ZTx). The structural properties of ZSM-5 and ZTx were characterized by XRD, FTIR, TGA/DTG, nitrogen adsorption/desorption, SEM and EDX techniques. The adsorption capacity of the adsorbents with different amine loading was measured at a temperature from 40 to 100 °C and the adsorption capacity of ZT7 was 1.80 mmol/g at 100 °C. The adsorption process and mechanism were studied by fitting the experimental data used the three adsorption kinetic models, and a complex physical and chemical mixing process was produced as the amine entered the surface and pore size of the zeolite. The high adsorption selectivity at 10% CO2 concentration and the stability of the five adsorption desorption cycles indicated that ZT7 is a suitable and promising CO2 adsorbent for the purification of industrial flue gas.

  16. Control of p-type and n-type thermoelectric properties of bismuth telluride thin films by combinatorial sputter coating technology

    NASA Astrophysics Data System (ADS)

    Goto, Masahiro; Sasaki, Michiko; Xu, Yibin; Zhan, Tianzhuo; Isoda, Yukihiro; Shinohara, Yoshikazu

    2017-06-01

    p- and n-type bismuth telluride thin films have been synthesized by using a combinatorial sputter coating system (COSCOS). The crystal structure and crystal preferred orientation of the thin films were changed by controlling the coating condition of the radio frequency (RF) power during the sputter coating. As a result, the p- and n-type films and their dimensionless figure of merit (ZT) were optimized by the technique. The properties of the thin films such as the crystal structure, crystal preferred orientation, material composition and surface morphology were analyzed by X-ray diffraction, energy-dispersive X-ray spectroscopy and atomic force microscopy. Also, the thermoelectric properties of the Seebeck coefficient, electrical conductivity and thermal conductivity were measured. ZT for n- and p-type bismuth telluride thin films was found to be 0.27 and 0.40 at RF powers of 90 and 120 W, respectively. The proposed technology can be used to fabricate thermoelectric p-n modules of bismuth telluride without any doping process.

  17. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  18. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  19. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...

  20. 40 CFR 610.61 - Engine dynamometer tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... dynamometer durability test procedures used by research organizations in government, the oil industry, engine... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Engine dynamometer tests. 610.61... ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.61 Engine...